A3COM-PRIVATE-MIB

File: A3COM-PRIVATE-MIB.mib (67320 bytes)

Imported modules

RFC1213-MIB RFC1155-SMI SNMPv2-SMI
SNMPv2-TC

Imported symbols

ifIndex mgmt Counter
IpAddress enterprises OBJECT-TYPE
Integer32 Counter32 TEXTUAL-CONVENTION
DisplayString RowStatus TruthValue
MacAddress

Defined Types

LineEntry  
SEQUENCE    
  lineIndex Integer32
  lineDataBits Integer32
  lineParity INTEGER
  lineSpeed Integer32
  lineStopBits Integer32

PortEntry  
SEQUENCE    
  portIndex Integer32
  portName DisplayString
  portType INTEGER
  portSpeedDpxCfg INTEGER
  portFlowCtrlCfg INTEGER
  portCapabilities INTEGER
  portAutonegotiation INTEGER
  portSpeedDpxStatus INTEGER
  portFlowCtrlStatus INTEGER

Dot11AuthenticationServerEntry  
SEQUENCE    
  dot11AuthenticationServerIndex Integer32
  dot11AuthenticationServer IpAddress
  dot11AuthenticationPort INTEGER
  dot11AuthenticationKey DisplayString
  dot11AuthenticationRetransmit INTEGER
  dot11AuthenticationTimeout INTEGER
  dot11AuthenticationAcctPort INTEGER
  dot11AuthenticationInterimUpdate INTEGER

Dot11FilterEntry  
SEQUENCE    
  dot11FilterAddress MacAddress
  dot11FilterStatus INTEGER

Dot11AuthenticationSupplicantEntry  
SEQUENCE    
  dot118021xSuppIndex Integer32
  dot118021xSuppState INTEGER
  dot118021xSuppUser DisplayString
  dot118021xSuppPasswd DisplayString

EnterpriseApSecurityEntry  
SEQUENCE    
  enterpriseApSecurityIndex Integer32
  enterpriseApSecurityAuthType INTEGER
  enterpriseApSecuritySharedKeyLen INTEGER
  enterpriseApSecurityWPAMode INTEGER
  enterpriseApSecurityWPAKeyType INTEGER
  enterpriseApSecurityWPACipher INTEGER
  enterpriseApSecurityWPAPSKType INTEGER
  enterpriseApSecurityWPAPSK DisplayString
  enterpriseApSecurityWEPKeyType INTEGER
  enterpriseApSecurityWEPEnabled TruthValue

EnterpriseApRadioEntry  
SEQUENCE    
  enterpriseApRadioIndex Integer32
  enterpriseApRadioAutoChannel INTEGER
  enterpriseApRadioTransmitPower INTEGER
  enterpriseApRadioTurboMode INTEGER
  enterpriseApRadioDataRate INTEGER
  enterpriseApRadioGMode INTEGER
  enterpriseApRadioAntennaMode INTEGER
  rogueApState INTEGER
  rogueApInterval INTEGER
  rogueApDuration INTEGER
  rogueApScanNow INTEGER

EnterpriseApVapRadioEntry  
SEQUENCE    
  enterpriseApVapRadioIndex Integer32
  enterpriseApVapRadioState INTEGER
  enterpriseApVapRadioClosedSystem INTEGER
  enterpriseApVapRadioMaxAssoc INTEGER
  enterpriseApVapRadioTransmitKey INTEGER
  enterpriseApVapRadioDescription DisplayString

RadioWdsEntry  
SEQUENCE    
  wdsApRole INTEGER

RadioWdsPeerEntry  
SEQUENCE    
  wdsPeerIndex Integer32
  wdsPeerBssid DisplayString

RogueApEntry  
SEQUENCE    
  rogueApIndex INTEGER
  rogueApBssid DisplayString
  rogueApSsid DisplayString
  rogueApPortNumber Integer32
  rogueApChannelNumber Integer32
  rogueApRSSIValue Integer32

Defined Values

a3Com 1.3.6.1.4.1.43
OBJECT IDENTIFIER    

wlan-mib 1.3.6.1.4.1.43.35
OBJECT IDENTIFIER    

rivet 1.3.6.1.4.1.43.35.8
The management information definitions for the 3COM AP-PRIVATE-MIB.
MODULE-IDENTITY    

enterpriseApSys 1.3.6.1.4.1.43.35.8.1
OBJECT IDENTIFIER    

enterpriseApLineMgnt 1.3.6.1.4.1.43.35.8.2
OBJECT IDENTIFIER    

enterpriseApPortMgnt 1.3.6.1.4.1.43.35.8.3
OBJECT IDENTIFIER    

enterpriseApFileTransferMgt 1.3.6.1.4.1.43.35.8.4
OBJECT IDENTIFIER    

enterpriseApResetMgt 1.3.6.1.4.1.43.35.8.5
OBJECT IDENTIFIER    

enterpriseApIpMgt 1.3.6.1.4.1.43.35.8.6
OBJECT IDENTIFIER    

enterpriseAPdot11 1.3.6.1.4.1.43.35.8.7
OBJECT IDENTIFIER    

enterpriseApAdmin 1.3.6.1.4.1.43.35.8.8
OBJECT IDENTIFIER    

enterpriseApSecurity 1.3.6.1.4.1.43.35.8.9
OBJECT IDENTIFIER    

enterpriseApRadio 1.3.6.1.4.1.43.35.8.10
OBJECT IDENTIFIER    

enterpriseApWebRedirection 1.3.6.1.4.1.43.35.8.11
OBJECT IDENTIFIER    

enterpriseApProxyArp 1.3.6.1.4.1.43.35.8.12
OBJECT IDENTIFIER    

enterpriseApRogueAp 1.3.6.1.4.1.43.35.8.13
OBJECT IDENTIFIER    

apNotificationTrapTree 1.3.6.1.4.1.43.35.8.100
OBJECT IDENTIFIER    

swHardwareVer 1.3.6.1.4.1.43.35.8.1.1
Hardware version of the main board.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..20)  

swBootRomVer 1.3.6.1.4.1.43.35.8.1.2
Boot ROM code version of the main board.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..20)  

swOpCodeVer 1.3.6.1.4.1.43.35.8.1.3
Operation code version of the main board.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..20)  

swSerialNumber 1.3.6.1.4.1.43.35.8.1.4
Serial Number of the Access Point.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..20)  

lineTable 1.3.6.1.4.1.43.35.8.2.1
Table of descriptive and status information about configuration of each RS-232 line in this system
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LineEntry

lineEntry 1.3.6.1.4.1.43.35.8.2.1.1
An entry in the table, containing information about configuration in one RS232 line of the Access Point.
Status: current Access: not-accessible
OBJECT-TYPE    
  LineEntry  

lineIndex 1.3.6.1.4.1.43.35.8.2.1.1.1
This is defined as RS-232 index.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

lineDataBits 1.3.6.1.4.1.43.35.8.2.1.1.2
This is defined as number of data bits for the RS232 interface.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

lineParity 1.3.6.1.4.1.43.35.8.2.1.1.3
This is defined as parity of the RS232 interface.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(99), odd(1), even(2)  

lineSpeed 1.3.6.1.4.1.43.35.8.2.1.1.4
This is defined as the speed of the RS-232 interface.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

lineStopBits 1.3.6.1.4.1.43.35.8.2.1.1.5
This is defined as the number of stop bits for the RS-232 interface.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

portTable 1.3.6.1.4.1.43.35.8.3.1
Table of descriptive and status information about configuration of each switch port (including expansion slot) in this system. This table also contains information about each trunk (similar to Cisco's EtherChannel).
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PortEntry

portEntry 1.3.6.1.4.1.43.35.8.3.1.1
An entry in the table, containing information about configuration in one switch port of the switch.
Status: current Access: not-accessible
OBJECT-TYPE    
  PortEntry  

portIndex 1.3.6.1.4.1.43.35.8.3.1.1.1
This is defined as ifIndex in the IF-MIB.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

portName 1.3.6.1.4.1.43.35.8.3.1.1.2
Indicates the port name. This is same as ifAlias in the IF-MIB (RFC2863 or later).
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

portType 1.3.6.1.4.1.43.35.8.3.1.1.3
Indicates the port type.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER other(1), hundredBaseTX(2), hundredBaseFX(3), thousandBaseSX(4), thousandBaseLX(5), thousandBaseT(6), thousandBaseGBIC(7), thousandBaseMiniGBIC(8)  

portSpeedDpxCfg 1.3.6.1.4.1.43.35.8.3.1.1.4
Set the port speed and duplex mode as follows: halfDuplex10(2) - 10Mbps and half duplex mode fullDuplex10(3) - 10Mbps and full duplex mode halfDuplex100(4) - 100Mbps and half duplex mode fullDuplex100(5) - 100Mbps and full duplex mode halfDuplex1000(6) - 1000Mbps and half duplex mode fullDuplex1000(7) - 1000Mbps and full duplex mode hundredBaseTX port can be set as halfDuplex10(2) fullDuplex10(3) halfDuplex100(4) fullDuplex100(5) hundredBaseFX port can be set as halfDuplex100(4) fullDuplex100(5) thousandBaseSX port can be set as halfDuplex1000(6) fullDuplex1000(7) The actual operating speed and duplex of the port is given by portSpeedDpxStatus.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER reserved(1), halfDuplex10(2), fullDuplex10(3), halfDuplex100(4), fullDuplex100(5), halfDuplex1000(6), fullDuplex1000(7)  

portFlowCtrlCfg 1.3.6.1.4.1.43.35.8.3.1.1.5
(1) Flow control mechanism is enabled. If the port type is hundredBaseTX or thousandBaseSX: When the port is operating in halfDuplex mode, the port uses backPressure flow control mechanism. When the port is operating in fullDuplex mode, the port uses IEEE 802.3x flow control mechanism. If the port type is hundredBaseFX: When the port is operating in halfDuplex mode, the port uses backPressure flow control mechanism. When the port is operating in fullDuplex mode, Flow control mechanism will not function. (2) Flow control mechanism is disabled. (3) Flow control mechanism is backPressure. when the port is in fullDuplex mode.This flow control mechanism will not function. (4) Flow control mechanism is IEEE 802.3x flow control. when the port is in halfDuplex mode.This flow control mechanism will not function. hundredBaseTX and thousandBaseSX port can be set as: enabled(1), disabled(2), backPressure(3), dot3xFlowControl(4). hundredBaseFX port can be set as: enabled(1), disabled(2), backPressure(3). The actual flow control mechanism is used given by portFlowCtrlStatus.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), backPressure(3), dot3xFlowControl(4)  

portCapabilities 1.3.6.1.4.1.43.35.8.3.1.1.6
Port capabilities.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER portCap10half(99), portCap10full(1), portCap100half(2), portCap100full(3), portCap1000half(4), portCap1000full(5), reserved6(6), reserved7(7), reserved8(8), reserved9(9), reserved10(10), reserved11(11), reserved12(12), reserved13(13), portCapSym(14), portCapFlowCtrl(15)  

portAutonegotiation 1.3.6.1.4.1.43.35.8.3.1.1.7
Whether autonegotiation is enabled.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

portSpeedDpxStatus 1.3.6.1.4.1.43.35.8.3.1.1.8
The operating speed and duplex mode of the switched port. If this index is a trunk, the speed is the speed of its individual members. If this index is a trunk and the result is inconsistent among its member ports, this value is error(1).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER error(1), halfDuplex10(2), fullDuplex10(3), halfDuplex100(4), fullDuplex100(5), halfDuplex1000(6), fullDuplex1000(7)  

portFlowCtrlStatus 1.3.6.1.4.1.43.35.8.3.1.1.9
(2) BackPressure flow control machanism is used. (3) IEEE 802.3 flow control machanism is used. (4) Flow control mechanism is disabled. If this index is a trunk and the result is inconsistent among its member ports, this value is error(1).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER error(1), backPressure(2), dot3xFlowControl(3), none(4)  

transferType 1.3.6.1.4.1.43.35.8.4.1
Type of file to transfer.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ftp(1), tftp(2)  

fileType 1.3.6.1.4.1.43.35.8.4.2
Type of file to transfer.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER application(1), config(2)  

srcFile 1.3.6.1.4.1.43.35.8.4.3
The source file name for TFTP transfer when a transfer is next requested via this MIB. This value is set to the zero length string when no file name has been specified.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..127)  

destFile 1.3.6.1.4.1.43.35.8.4.4
The destination file name for TFTP transfer when a transfer is next requested via this MIB. This value is set to the zero length string when no file name has been specified.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..127)  

fileServer 1.3.6.1.4.1.43.35.8.4.5
The IP address of the TFTP server for transfer when a download is next requested via this MIB. This value is set to `0.0.0.0' when no IP address has been specified.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

userName 1.3.6.1.4.1.43.35.8.4.6
The username specified for an FTP Transfer.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..127)  

password 1.3.6.1.4.1.43.35.8.4.7
The password specified for an FTP Transfer.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..127)  

status 1.3.6.1.4.1.43.35.8.4.8
The status of the transfer.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER running(1), success(2), failureGeneric(3), flashOpenError(10), flashMallocError(11), flashReadError(12), flashFtypeError(13), socketWriteError(20), protocolError(30)  

transferStart 1.3.6.1.4.1.43.35.8.4.9
To start a transfer.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER download(1), upload(2)  

restartOpCodeFile 1.3.6.1.4.1.43.35.8.5.1
Name of op-code file for start-up.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..127)  

restartControl 1.3.6.1.4.1.43.35.8.5.2
Setting this object to warmBoot(2) causes the device to restart the application software with current configuration parameters saved in non-volatile memory. Setting this object to coldBoot(3) causes the device to reinitialize configuration parameters in non-volatile memory to default values and restart the application software. When the device is running normally, this variable has a value of running(1).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER running(1), warmBoot(2), coldBoot(3)  

netConfigIPAddress 1.3.6.1.4.1.43.35.8.6.1
The IP address of this Net interface. The default value for this object is 0.0.0.0. If either the netConfigIPAddress or netConfigSubnetMask are 0.0.0.0, then when the device boots, it may use DHCP to try to figure out what these values should be. If DHCP fails, before the device can talk on the network, this value must be configured (e.g., through a terminal attached to the device).
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

netConfigSubnetMask 1.3.6.1.4.1.43.35.8.6.2
The subnet mask of this Net interface. The default value for this object is 0.0.0.0. If either the netConfigIPAddress or netConfigSubnetMask are 0.0.0.0, then when the device boots, it may use DHCP to try to figure out what these values should be. If DHCP fails, before the device can talk on the network, this value must be configured (e.g., through a terminal attached to the device).
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

netConfigDefaultGateway 1.3.6.1.4.1.43.35.8.6.3
The IP Address of the default gateway. If this value is undefined or unknown, it shall have the value 0.0.0.0.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

netConfigHttpState 1.3.6.1.4.1.43.35.8.6.4
Whether HTTP is enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

netConfigHttpPort 1.3.6.1.4.1.43.35.8.6.5
The port number for HTTP. Default value is 80.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1024..65535  

netConfigHttpsState 1.3.6.1.4.1.43.35.8.6.6
Whether Secure HTTP is enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

netConfigHttpsPort 1.3.6.1.4.1.43.35.8.6.7
The port number for Secure HTTP. Default value is 443.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1024..65535  

netConfigDHCPState 1.3.6.1.4.1.43.35.8.6.8
Whether DHCP is enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

dot11AuthenticationEntry 1.3.6.1.4.1.43.35.8.7.5
OBJECT IDENTIFIER    

dot118021xState 1.3.6.1.4.1.43.35.8.7.5.1
This attribute indicates that the Enterprise the state of the 802.1x authentication algorithm.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), supported(1), required(2)  

dot118021xBroadcastKeyRefreshRate 1.3.6.1.4.1.43.35.8.7.5.2
The number (in minutes) between changing the broadcast key for 802.1x and WPA clients
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1440  

dot118021xSessionKeyRefreshRate 1.3.6.1.4.1.43.35.8.7.5.3
The number (in minutes) between changing session keys for 802.1x and WPA clients
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1440  

dot118021xReauthenticationTimeout 1.3.6.1.4.1.43.35.8.7.5.4
The number (in minutes) between forcing 802.1x clients to reauthenticate
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1440  

dot11MACAuthenticationType 1.3.6.1.4.1.43.35.8.7.5.5
This value indicates the type of mac authentication in use.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), local(1), radius(2)  

dot11AuthenticationServerTable 1.3.6.1.4.1.43.35.8.7.6
Table of descriptive and status information about configuration of each authentication server.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Dot11AuthenticationServerEntry

dot11AuthenticationServerEntry 1.3.6.1.4.1.43.35.8.7.6.1
An entry in the table, containing information about configuration of one authentication server of the AP.
Status: current Access: not-accessible
OBJECT-TYPE    
  Dot11AuthenticationServerEntry  

dot11AuthenticationServerIndex 1.3.6.1.4.1.43.35.8.7.6.1.1
Index of the Authentication Server
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

dot11AuthenticationServer 1.3.6.1.4.1.43.35.8.7.6.1.2
This value indicates the IP address of the authentication server.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

dot11AuthenticationPort 1.3.6.1.4.1.43.35.8.7.6.1.3
This value indicates the UDP Port used by the authentication server.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1024..65535  

dot11AuthenticationKey 1.3.6.1.4.1.43.35.8.7.6.1.4
This value indicates the shared key used by the authentication server.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..20)  

dot11AuthenticationRetransmit 1.3.6.1.4.1.43.35.8.7.6.1.5
This value indicates the retransmit timer length used by the authentication server.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..30  

dot11AuthenticationTimeout 1.3.6.1.4.1.43.35.8.7.6.1.6
This value indicates the Timeout value(sec) used by the authentication server.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..60  

dot11AuthenticationAcctPort 1.3.6.1.4.1.43.35.8.7.6.1.7
The port number for radius server accounting.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1024..65535  

dot11AuthenticationInterimUpdate 1.3.6.1.4.1.43.35.8.7.6.1.8
This value indicates the Timeout value(sec) used by the radius server interim update.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 60..86400  

dot11Filter 1.3.6.1.4.1.43.35.8.7.7
OBJECT IDENTIFIER    

dot11FilterDefault 1.3.6.1.4.1.43.35.8.7.7.1
This value indicates the default access for local mac filters.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER allow(1), deny(2)  

dot11FilterTable 1.3.6.1.4.1.43.35.8.7.7.2
Table of status information about each configured MAC Address Filtering Entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Dot11FilterEntry

dot11FilterEntry 1.3.6.1.4.1.43.35.8.7.7.2.1
An entry in the table, containing information about configuration in one radio of the AP.
Status: current Access: not-accessible
OBJECT-TYPE    
  Dot11FilterEntry  

dot11FilterAddress 1.3.6.1.4.1.43.35.8.7.7.2.1.1
This value indicates the MAC address of the filter entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  MacAddress  

dot11FilterStatus 1.3.6.1.4.1.43.35.8.7.7.2.1.2
This value indicates the Status of the filter entry. Ifallowed, the client is allowed access to the network. If disallowed, the no frames will be forwarded to the network from the client.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER allowed(30), denied(31), delete(32)  

dot11AuthenticationSupplicantTable 1.3.6.1.4.1.43.35.8.7.8
Table of descriptive and status information about configuration of supplicant
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Dot11AuthenticationSupplicantEntry

dot11AuthenticationSupplicantEntry 1.3.6.1.4.1.43.35.8.7.8.1
An entry in the table, containing information about configuration of one supplicant.
Status: current Access: not-accessible
OBJECT-TYPE    
  Dot11AuthenticationSupplicantEntry  

dot118021xSuppIndex 1.3.6.1.4.1.43.35.8.7.8.1.1
Index of the interface for which this supplicant is running. Currently only the ethernet interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

dot118021xSuppState 1.3.6.1.4.1.43.35.8.7.8.1.2
This object is used to enable or disable the 802.1x supplicant.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

dot118021xSuppUser 1.3.6.1.4.1.43.35.8.7.8.1.3
This value indicates the username for supplicant. If value is configured, will display ****. Else will display EMPTY.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..32)  

dot118021xSuppPasswd 1.3.6.1.4.1.43.35.8.7.8.1.4
This value indicates the password for supplicant. If value is configured, will display ****. Else will display EMPTY.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..32)  

enterpriseApAdminUser 1.3.6.1.4.1.43.35.8.8.1
This value indicates the username for management login.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(3..16)  

enterpriseApAdminPassword 1.3.6.1.4.1.43.35.8.8.2
This value indicates the password for management login. Accept empty string to remove the password.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(3..16)  

enterpriseApSecurityTable 1.3.6.1.4.1.43.35.8.9.1
Table of descriptive and status information about configuration of each radio in terms of security settings.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EnterpriseApSecurityEntry

enterpriseApSecurityEntry 1.3.6.1.4.1.43.35.8.9.1.1
An entry in the table, containing information about configuration of one radio of the AP.
Status: current Access: not-accessible
OBJECT-TYPE    
  EnterpriseApSecurityEntry  

enterpriseApSecurityIndex 1.3.6.1.4.1.43.35.8.9.1.1.1
Radio Index for security settings.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

enterpriseApSecurityAuthType 1.3.6.1.4.1.43.35.8.9.1.1.2
This value indicates the type of authentication in use for this radio interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER open(0), shared(1)  

enterpriseApSecuritySharedKeyLen 1.3.6.1.4.1.43.35.8.9.1.1.3
This value indicates the shared key length for this radio interface.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(0), sixtyFour(1), oneHundredTwentyEight(2), oneHundredFiftyTwo(3)  

enterpriseApSecurityWPAMode 1.3.6.1.4.1.43.35.8.9.1.1.4
This value indicates the state of WPA for this radio interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER supported(0), required(1), disabled(2)  

enterpriseApSecurityWPAKeyType 1.3.6.1.4.1.43.35.8.9.1.1.5
This value indicates the type of WPA Key Management in use for this radio interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER dot1x(0), presharedkey(1)  

enterpriseApSecurityWPACipher 1.3.6.1.4.1.43.35.8.9.1.1.6
This value indicates the type of WPA Cipher in use for this radio interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER wep(0), tkip(1), aes(2)  

enterpriseApSecurityWPAPSKType 1.3.6.1.4.1.43.35.8.9.1.1.7
This value indicates the type of WPA Pre Shared Key in use for this radio interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER hex(0), alphanumeric(1)  

enterpriseApSecurityWPAPSK 1.3.6.1.4.1.43.35.8.9.1.1.8
This value indicates WPA Pre Shared Key in use for this radio interface.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..64)  

enterpriseApSecurityWEPKeyType 1.3.6.1.4.1.43.35.8.9.1.1.9
This value indicates the type of WEP Key in use for this radio interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER hexadecimal(0), alphanumeric(1)  

enterpriseApSecurityWEPEnabled 1.3.6.1.4.1.43.35.8.9.1.1.10
This value indicates whether WEP is enabled.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

enterpriseApRadioTable 1.3.6.1.4.1.43.35.8.10.1
Table of descriptive and status information about configuration of each radio.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EnterpriseApRadioEntry

enterpriseApRadioEntry 1.3.6.1.4.1.43.35.8.10.1.1
An entry in the table, containing information about configuration of one radio of the AP.
Status: current Access: not-accessible
OBJECT-TYPE    
  EnterpriseApRadioEntry  

enterpriseApRadioIndex 1.3.6.1.4.1.43.35.8.10.1.1.1
Radio Index for configuration.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

enterpriseApRadioAutoChannel 1.3.6.1.4.1.43.35.8.10.1.1.2
This value indicates whether auto channel selection is enabled or not for this radio interface
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

enterpriseApRadioTransmitPower 1.3.6.1.4.1.43.35.8.10.1.1.3
This value indicates the transmit power for this radio interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER full(1), half(2), middle(3), quarter(4), eighth(5), min(6)  

enterpriseApRadioTurboMode 1.3.6.1.4.1.43.35.8.10.1.1.4
This value indicates whether turbo mode is enabled for this radio interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), invalid(3)  

enterpriseApRadioDataRate 1.3.6.1.4.1.43.35.8.10.1.1.5
This value indicates the data rate for this radio interface. Radio interface A operates at 6, 9, 12, 18, 24, 36, 48, 54. Radio interface G operates all listed data rates. The auto setting will attempt to set the best data rate for the interface
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER oneMbps(1), twoMbps(2), fiveAndHalfMbps(5), sixMbps(6), nineMbps(9), elevenMbps(11), twelveMbps(12), eighteenMbps(18), twentyFourMbps(24), thirtySixMbps(36), fourtyEightMbps(48), fiftyFourMbps(54), auto(255)  

enterpriseApRadioGMode 1.3.6.1.4.1.43.35.8.10.1.1.6
This value indicates the radio mode for the 802.11g radio. This setting is only valid for the 802.11g interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER bOnly(1), gOnly(2), bg(3), invalid(4)  

enterpriseApRadioAntennaMode 1.3.6.1.4.1.43.35.8.10.1.1.7
This value indicates the antenna mode in use for the G-radio. The values are interpreted as follows: both(1) means use both built-in antennas, left(2) means use left side. right(3) means use right side. invalid(4) means not support. This setting is only valid for the 802.11g interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER both(1), left(2), right(3), invalid(4)  

rogueApState 1.3.6.1.4.1.43.35.8.10.1.1.8
This value is used to enable/disable Rogue Ap Detection for this radio interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

rogueApInterval 1.3.6.1.4.1.43.35.8.10.1.1.9
How often to scan for Rogue Aps. The interval in minutes, with default of 720(minutes).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 60..10080  

rogueApDuration 1.3.6.1.4.1.43.35.8.10.1.1.10
How long to scan each channel (in milliseconds). A longer duration will yield more complete results. A shorter duration will allow clients a better chance of remaining connected. Default value is 350(milliseconds).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 200..1000  

rogueApScanNow 1.3.6.1.4.1.43.35.8.10.1.1.11
When writing the value to enable, the AP will trigger the Rouge AP scan function. The value will always return disable(2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

enterpriseApVapRadioTable 1.3.6.1.4.1.43.35.8.10.2
Table of descriptive and status information about configuration of each Vap radio.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EnterpriseApVapRadioEntry

enterpriseApVapRadioEntry 1.3.6.1.4.1.43.35.8.10.2.1
An entry in the table, containing information about configuration of one Vap radio of the AP.
Status: current Access: not-accessible
OBJECT-TYPE    
  EnterpriseApVapRadioEntry  

enterpriseApVapRadioIndex 1.3.6.1.4.1.43.35.8.10.2.1.1
Radio Index for configuration.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

enterpriseApVapRadioState 1.3.6.1.4.1.43.35.8.10.2.1.2
This value indicates the state of the radio interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

enterpriseApVapRadioClosedSystem 1.3.6.1.4.1.43.35.8.10.2.1.3
This value indicates whether closed system is enabled for this radio interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

enterpriseApVapRadioMaxAssoc 1.3.6.1.4.1.43.35.8.10.2.1.4
This value indicates the max number of clients allowed on this radio interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..64  

enterpriseApVapRadioTransmitKey 1.3.6.1.4.1.43.35.8.10.2.1.5
This value indicates default transmit key in use for this radio interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..4  

enterpriseApVapRadioDescription 1.3.6.1.4.1.43.35.8.10.2.1.6
This value indicates the description for this radio interface.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..80)  

radioWdsTable 1.3.6.1.4.1.43.35.8.10.3
Table of configuration information for Wds for each Radio interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RadioWdsEntry

radioWdsEntry 1.3.6.1.4.1.43.35.8.10.3.1
An entry in the table, containing information about configuration of peer Bridging for one radio of the AP. The table is indexed by radio Index (corresponding to enterpriseApRadioTable). The table does not contain the radio index as a member of the table.
Status: current Access: not-accessible
OBJECT-TYPE    
  RadioWdsEntry  

wdsApRole 1.3.6.1.4.1.43.35.8.10.3.1.1
This value indicates the role of the Ap for this radio: normal operation(1), bridge master(2) which accepts only repeaters to associate with, repeater Ap(3) that accepts wireless station and other repeaters if it is root-connected: bridge-connected or root connected, and bridge(4) which bridges ethernet traffic to WDS parent bridge but does not relay wireless traffic.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER roleAp(1), roleBridgeMaster(2), roleRepeater(3), roleBridge(4)  

radioWdsPeerTable 1.3.6.1.4.1.43.35.8.10.4
Table of configuration information for Wds Peers for each Radio interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RadioWdsPeerEntry

radioWdsPeerEntry 1.3.6.1.4.1.43.35.8.10.4.1
An entry in the table, containing information about configuration of peer Bridging for one radio of the AP. The table is indexed by radio Index (corresponding to enterpriseApRadioTable) and the peer index (Up to 6). The table does not contain the radio index as a member of the table.
Status: current Access: not-accessible
OBJECT-TYPE    
  RadioWdsPeerEntry  

wdsPeerIndex 1.3.6.1.4.1.43.35.8.10.4.1.1
Peer Index for the radio interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

wdsPeerBssid 1.3.6.1.4.1.43.35.8.10.4.1.2
The BSSID for this peer.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..6)  

webRedirectionEnabled 1.3.6.1.4.1.43.35.8.11.1
Whether Web Redirection is enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

proxyArpEnabled 1.3.6.1.4.1.43.35.8.12.1
Whether ProxyArp is enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

rogueApDetectionTable 1.3.6.1.4.1.43.35.8.13.1
Table of each AP that has been detected.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RogueApEntry

rogueApEntry 1.3.6.1.4.1.43.35.8.13.1.1
An entry in the table, containing information about any AP detected.
Status: current Access: not-accessible
OBJECT-TYPE    
  RogueApEntry  

rogueApIndex 1.3.6.1.4.1.43.35.8.13.1.1.1
Monotonically increasing index.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..128  

rogueApBssid 1.3.6.1.4.1.43.35.8.13.1.1.2
The AP BSSID
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..6)  

rogueApSsid 1.3.6.1.4.1.43.35.8.13.1.1.3
The AP SSID
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..40)  

rogueApPortNumber 1.3.6.1.4.1.43.35.8.13.1.1.4
Interface index for the radio.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rogueApChannelNumber 1.3.6.1.4.1.43.35.8.13.1.1.5
Channel where Ap detected.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rogueApRSSIValue 1.3.6.1.4.1.43.35.8.13.1.1.6
RSSI for AP detected.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

apNotificationObjects 1.3.6.1.4.1.43.35.8.100.1
OBJECT IDENTIFIER    

apNotificationDot11MacAddr 1.3.6.1.4.1.43.35.8.100.1.1
Mac Address of the affected interface, returned with traps only.
Status: current Access: not-accessible
OBJECT-TYPE    
  MacAddress  

apNotificationDot11Station 1.3.6.1.4.1.43.35.8.100.1.2
This attribute holds the MAC address of the wireless station
Status: current Access: not-accessible
OBJECT-TYPE    
  MacAddress  

apNotificationDot11RequestType 1.3.6.1.4.1.43.35.8.100.1.3
This attribute defines the request type sent by the station. Value = 1: Unknown request type Value = 2: Association Request Value = 3: Re-association Request Value = 4: Authentication
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER unknown(1), association(2), reAssociation(3), authentication(4)  

apNotificationDot11ReasonCode 1.3.6.1.4.1.43.35.8.100.1.4
This attribute defines the reason for the failure of an operation. Value = 1: Invalid mode/state Value = 2: Station not authenticated. Value = 3: Internal error Value = 4: Out of sequence frame Value = 5: Un-supportd algorithm Value = 6: Invalid frame length Value = 7: WEP is required on the AP Value = 8: WEP not allowed Value = 9: Challenge text mismatch
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER invalidModeOrState(1), unAuthenticatedStation(2), internalError(3), outOfSequenceFrame(4), unsupportedAlgorithm(5), invalidFrameLngth(6), wepRequiredOnAP(7), wepNotAllowed(8), challengeTextMismatch(9)  

apNotificationDot11IpAddress 1.3.6.1.4.1.43.35.8.100.1.5
This value indicates the IP address of the Access Point
Status: current Access: not-accessible
OBJECT-TYPE    
  IpAddress  

apNotificationDot11AuthenticatorMacAddr 1.3.6.1.4.1.43.35.8.100.1.6
This attribute holds the MAC address of the authenticator for the AP.
Status: current Access: not-accessible
OBJECT-TYPE    
  MacAddress  

apNotificationTrapObjects 1.3.6.1.4.1.43.35.8.100.2
OBJECT IDENTIFIER    

sysSystemUp 1.3.6.1.4.1.43.35.8.100.2.1
The system up notification shall be sent when the AP is fully up and running.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sysSystemDown 1.3.6.1.4.1.43.35.8.100.2.2
The system down notification shall be sent before the AP is about to reboot.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sysRadiusServerChanged 1.3.6.1.4.1.43.35.8.100.2.3
The RADIUS server changed notification shall be sent when the RADIUS server has changed from Primary / Secondary to Secondary / Primary.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

dot11StationAssociation 1.3.6.1.4.1.43.35.8.100.2.4
The associate notification shall be sent when a station successfully associates with the Access Point. The value of the notification shall include the MAC address of the station that has associated.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

dot11StationReAssociation 1.3.6.1.4.1.43.35.8.100.2.5
The re-associate notification shall be sent when a station successfully re-associates with the Access Point. The value of the notification shall include the MAC address of the station that has associated.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

dot11StationAuthentication 1.3.6.1.4.1.43.35.8.100.2.6
The authentication notification shall be sent when a station successfully authenticates with the Access Point. The value of the notification shall include the MAC address of the station that has authenticated.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

dot11StationRequestFail 1.3.6.1.4.1.43.35.8.100.2.7
The station request fail shall be sent out when a station fails to associate / re-associate / authenticate with the Access Point. The notification shall include the MAC address of the station and the reason code for the failure.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

dot11InterfaceAGFail 1.3.6.1.4.1.43.35.8.100.2.8
The InterfaceAGFail notification shall be sent out when 802.11a/802.11g wireless interface has failed.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

dot1xMacAddrAuthSuccess 1.3.6.1.4.1.43.35.8.100.2.9
The 802.1x MAC address authentication success notification shall be sent when a station successfully authenticates the MAC address with the RADIUS server. The value of the notification shall include the MAC address of the station that has authenticated.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

dot1xMacAddrAuthFail 1.3.6.1.4.1.43.35.8.100.2.10
The 802.1x MAC address authentication failure notification shall be sent when a station fails to authenticate the MAC address with the RADIUS server. The value of the notification shall include the MAC address of the station that failed to authenticate.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

dot1xAuthNotInitiated 1.3.6.1.4.1.43.35.8.100.2.11
The 802.1x authentication not initiated notification shall be sent when a station did not initiate 802.1x authentication with the RADIUS server. The value of the notification shall include the MAC address of the station that did not initiate 802.1x authentication.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

dot1xAuthSuccess 1.3.6.1.4.1.43.35.8.100.2.12
The 802.1x authentication success notification shall be sent when a station successfully authenticates with the RADIUS server. The value of the notification shall include the MAC address of the station that has authenticated.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

dot1xAuthFail 1.3.6.1.4.1.43.35.8.100.2.13
The 802.1x authentication failure notification shall be sent when a station fails to authenticate with the RADIUS server. The value of the notification shall include the MAC address of the station that failed to authenticate.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

localMacAddrAuthSuccess 1.3.6.1.4.1.43.35.8.100.2.14
The Local MAC address authentication success notification shall be sent when a station successfully authenticates the MAC address with the database stored locally within the AP. The value of the notification shall include the MAC address of the station that has authenticated.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

localMacAddrAuthFail 1.3.6.1.4.1.43.35.8.100.2.15
The Local MAC address authentication failure notification shall be sent when a station fails to authenticate the MAC address with the database stored locally within the AP. The value of the notification shall include the MAC address of the station that has authenticated.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

pppLogonFail 1.3.6.1.4.1.43.35.8.100.2.16
The PPP Logon failure notification shall be sent out when the AP fails to login successfully to the PPP peer using the supplied username and password.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

iappStationRoamedFrom 1.3.6.1.4.1.43.35.8.100.2.17
The IAPP Station Roamed-From Notification shall be sent out whenever a station roams from another Access Point (AP) to this AP. The notification shall include the MAC address of the station and the IP address of the old AP.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

iappStationRoamedTo 1.3.6.1.4.1.43.35.8.100.2.18
The IAPP Station Roamed-To Notification shall be sent out whenever a station roams to another Access Point (AP) from this AP. The notification shall include the MAC address of the station and the IP address of the new AP.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

iappContextDataSent 1.3.6.1.4.1.43.35.8.100.2.19
The IAPP Context Data Sent notification shall be sent out whenever the context data for a station has been sent to the new AP with which the station has associated. The notification shall include the MAC address of the station and the IP address of the new AP.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sntpServerFail 1.3.6.1.4.1.43.35.8.100.2.20
The sntpServerFail notification shall be sent when the AP fails to get time from the configured SNTP server.
Status: current Access: not-accessible
NOTIFICATION-TYPE