ACMIB

File: ACMIB.mib (1733896 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
RFC1213-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE OBJECT-IDENTITY
NOTIFICATION-TYPE Counter32 Integer32
IpAddress TimeTicks enterprises
TEXTUAL-CONVENTION DisplayString TimeStamp
RowStatus DateAndTime MODULE-COMPLIANCE
OBJECT-GROUP ifIndex mib-2

Defined Types

IntfIndex  
A INTEGER
TEXTUAL-CONVENTION    
  Integer32  

ConnFailureCause  
General connection failure cause
TEXTUAL-CONVENTION    
  INTEGER none(1), physical(2)  

FrConnFailureCause  
Frame Relay connection failure cause
TEXTUAL-CONVENTION    
  INTEGER none(1), physical(2), lmi(3), dlci(4)  

AtmConnFailureCause  
ATM connection failure cause
TEXTUAL-CONVENTION    
  INTEGER none(1), physical(2), oamAis(3), oamRdi(4)  

ImaGrpChannelEndState  
The current operational state of the Near-end or far-end IM A Group State Machine.
TEXTUAL-CONVENTION    
  INTEGER notConfigured(1), startUp(2), startUpAck(3), cfgAbtUnsupportedM(4), cfgAbtIncSymmetry(5), cfgAbtOther(6), insufficientLinks(7), blocked(8), operational(9)  

TasAnnceEntry  
SEQUENCE    
  tasAnnceId INTEGER
  tasAnnceType INTEGER
  tasAnnceCmprsType INTEGER
  tasAnnceValid INTEGER
  tasAnnceDescription DisplayString

TasToneConfigEntry  
SEQUENCE    
  tasToneId INTEGER
  tasToneType INTEGER
  tasToneFirstFreq INTEGER
  tasToneSecondFreq INTEGER
  tasToneThirdFreq INTEGER
  tasToneOnTime INTEGER
  tasToneOffTime INTEGER
  tasToneLevel INTEGER

FeatureEntry  
SEQUENCE    
  featureId INTEGER
  featureStaticMem Integer32
  featureDesiredStatus INTEGER
  featureCurrentStatus INTEGER

DspResourceEntry  
SEQUENCE    
  dspResourceId INTEGER
  dspResourceAvail Integer32
  dspResourceUsed Integer32
  dspResourceUsedFailed Integer32
  dspResourceAvailFailed Integer32

TrapActivationEntry  
SEQUENCE    
  trapGroupId INTEGER
  trapIndex Integer32
  trapActivationStatus INTEGER
  trapNames DisplayString
  resetAction INTEGER

CardEntry  
SEQUENCE    
  cardSlot INTEGER
  cardType INTEGER
  cardProtectionStatus INTEGER
  cardOperStatus INTEGER
  cardAdminStatus INTEGER
  cardAlarmStatus INTEGER
  cardCleiCode DisplayString
  cardRevision Integer32
  cardSerialNumber DisplayString
  cardOperatingMode INTEGER
  protectionConfigMode INTEGER
  protectionStatus INTEGER
  protectionSlot INTEGER

TaxiPortConfigEntry  
SEQUENCE    
  taxiPortId Integer32
  taxiPortType INTEGER
  taxiLineStatus INTEGER
  taxiOutputTransferRate INTEGER

Ds3PortConfigEntry  
SEQUENCE    
  ds3PortId Integer32
  ds3LineType INTEGER
  ds3LineCoding INTEGER
  ds3LoopbackConfig INTEGER
  ds3TransmitClockSource INTEGER
  ds3LineStatus INTEGER
  ds3LineBuildOut INTEGER
  ds3LineScramble INTEGER
  ds3CellMapping INTEGER
  ds3SendCode INTEGER
  ds3OutputTxRate INTEGER

MsPortConfigEntry  
SEQUENCE    
  msPortId IntfIndex
  msLineCoding INTEGER
  msBaudRate INTEGER
  msProtocol INTEGER
  msEquipmentType INTEGER
  msRs232XmitMode INTEGER
  msRs232Parity INTEGER
  msRs232DataBits INTEGER
  msRs232StopBits INTEGER
  msTxDataClkSrcForDte INTEGER
  msTxDataClkSrcForDce INTEGER
  msRxDataClkSrcForDce INTEGER
  msRxClkPolarity INTEGER
  msTxClkPolarity INTEGER
  msKgResync INTEGER
  msHandshake INTEGER
  msSpeedAdaption INTEGER
  msBitStuffing INTEGER
  msLineStatus INTEGER
  msRxDataPolarity INTEGER
  msTxDataPolarity INTEGER
  msLoopbackConfig INTEGER
  msLOSDetection INTEGER

Ds1PortConfigEntry  
SEQUENCE    
  ds1PortId Integer32
  ds1Channelization INTEGER
  ds1LineType INTEGER
  ds1LineCoding INTEGER
  ds1LoopbackConfig INTEGER
  ds1TransmitClockSource INTEGER
  ds1LineBuildOut INTEGER
  ds1LineStatus INTEGER
  ds1EnhanceFeatureSet1 INTEGER
  ds1DataTransferType INTEGER
  ds1OamInterworkingType INTEGER
  ds1ConnGatewayFeature INTEGER
  ds1InLineCode INTEGER

Oc3PortConfigEntry  
SEQUENCE    
  oc3PortId Integer32
  oc3LoopbackConfig INTEGER
  oc3TransmitClockSource INTEGER
  oc3LineStatus INTEGER
  oc3OutputTransferRate INTEGER
  oc3APSConfiguration INTEGER

Oc3APSPairConfigEntry  
SEQUENCE    
  oc3APSPairId Integer32
  oc3APSPairMode INTEGER
  oc3APSPairOption INTEGER
  oc3APSPairWorkingSFBERThreshold INTEGER
  oc3APSPairProtectionSFBERThreshold INTEGER
  oc3APSPairWorkingSDBERThreshold INTEGER
  oc3APSPairProtectionSDBERThreshold INTEGER
  oc3APSPairWTRPeriod INTEGER
  oc3APSWorkingSlot Integer32
  oc3APSProtectionSlot Integer32
  oc3APSActiveSlot Integer32
  oc3APSPairStatus INTEGER
  oc3APSPairUserCommand INTEGER
  oc3APSPairCurrentState INTEGER
  oc3APSPairWorkingLineSignalStatus INTEGER
  oc3APSPairProtectionLineSignalStatus INTEGER

Oc3APSPairStatsEntry  
SEQUENCE    
  oc3APSPairStatsId Integer32
  oc3APSPairWorkingSFDuration Integer32
  oc3APSPairWorkingSDDuration Integer32
  oc3APSPairProtectionSFDuration Integer32
  oc3APSPairProtectionSDDuration Integer32
  oc3APSPairTransmitK1K2Bytes OCTET STRING
  oc3APSPairReceiveK1K2Bytes OCTET STRING
  oc3APSPairSwitchOverCount Integer32

TwoWireSourcePortConfigEntry  
SEQUENCE    
  twoWireSourcePortId Integer32
  twoWireSourceLoopDetection INTEGER
  twoWireSourceDialMode INTEGER
  twoWireSourceLoopBackConfig INTEGER
  twoWireSourceLineStatus INTEGER
  twoWireSourceSignalingBits INTEGER
  twoWireSourceRingCadence INTEGER
  twoWireSourceSignalingState INTEGER
  twoWireSourceTestMode INTEGER

HighSpeedPortConfigEntry  
SEQUENCE    
  highSpeedPortId Integer32
  highSpeedPortInputRate Integer32
  highSpeedPortOutputRate Integer32

DspPortConfigEntry  
SEQUENCE    
  dspPortId Integer32

TwoWireSinkPortConfigEntry  
SEQUENCE    
  twoWireSinkPortId Integer32
  twoWireSinkLoopDetection INTEGER
  twoWireSinkDialMode INTEGER
  twoWireSinkLineStatus INTEGER
  twoWireSinkSignalingBits INTEGER
  twoWireSinkSignalingState INTEGER
  twoWireSinkTestMode INTEGER

E3PortConfigEntry  
SEQUENCE    
  e3PortId Integer32
  e3LineType INTEGER
  e3LineCoding INTEGER
  e3LoopbackConfig INTEGER
  e3TransmitClockSource INTEGER
  e3LineStatus INTEGER
  e3LineBuildOut INTEGER
  e3LineScramble INTEGER
  e3CellMapping INTEGER

E1PortConfigEntry  
SEQUENCE    
  e1PortId Integer32
  e1Channelization INTEGER
  e1LineType INTEGER
  e1LineCoding INTEGER
  e1LoopbackConfig INTEGER
  e1TransmitClockSource INTEGER
  e1LineNationalBits INTEGER
  e1LineStatus INTEGER
  e1TS16 INTEGER
  e1DataTransferType INTEGER
  e1CRC4 INTEGER
  e1OamInterworkingType INTEGER
  e1EnhanceFeatureSet1 INTEGER
  e1ConnGatewayFeature INTEGER

EthernetPortConfigEntry  
SEQUENCE    
  ethernetPortId Integer32
  ethernetLinkType INTEGER
  ethernetPhysicalAddr OCTET STRING
  ethernetLineStatus INTEGER
  ethernetDuplexMode INTEGER

Dsp2PortConfigEntry  
SEQUENCE    
  dsp2PortId Integer32

ImaPortConfigEntry  
SEQUENCE    
  imaPortId Integer32

Sts1PortConfigEntry  
SEQUENCE    
  sts1PortId IntfIndex
  sts1LineCoding INTEGER
  sts1LoopbackConfig INTEGER
  sts1TransmitClockSource INTEGER
  sts1LineBuildOut INTEGER
  sts1LineStatus INTEGER
  sts1StsPointers INTEGER
  sts1VtPointers INTEGER

TasmPortConfigEntry  
SEQUENCE    
  tasmPortId Integer32

ProtectionGroupConfigEntry  
SEQUENCE    
  protectionSlotId INTEGER
  workingSlotBitmap INTEGER
  protectionCommand INTEGER
  protectionCommandSlotId INTEGER
  protectionGroupStatus INTEGER
  workingSlotId INTEGER
  workingFailedBitmap INTEGER
  protectionActiveCounter Integer32
  protectionOOSCounter Integer32

TaxiChannelConfigEntry  
SEQUENCE    
  taxiChannelId IntfIndex
  taxiChannelIfType INTEGER
  taxiChannelSecuFeature INTEGER

Ds3ChannelConfigEntry  
SEQUENCE    
  ds3ChannelId IntfIndex
  ds3ChannelIfType INTEGER
  ds3ChannelSecuFeature INTEGER

Ds1ChannelConfigEntry  
SEQUENCE    
  ds1ChannelId IntfIndex
  ds1ChannelIfType INTEGER
  ds1ChannelDs0Map OCTET STRING
  ds1ChannelCellMapping INTEGER
  ds1ChannelInputCodingRule INTEGER
  ds1ChannelSecuFeature INTEGER
  ds1ChannelSignaling INTEGER
  ds1ChannelCellScramble INTEGER

MsChannelConfigEntry  
SEQUENCE    
  msChannelId IntfIndex
  msChannelIfType INTEGER
  msChannelCellBearingMode INTEGER
  msChannelCellBearingAddrMode INTEGER
  msChannelCellBearingPayloadFec INTEGER
  msChannelSecuFeature INTEGER

Oc3ChannelConfigEntry  
SEQUENCE    
  oc3ChannelId IntfIndex
  oc3ChannelIfType INTEGER
  oc3ChannelSecuFeature INTEGER

TwoWireSourceChannelConfigEntry  
SEQUENCE    
  twoWireSourceChannelId IntfIndex
  twoWireSourceChannelIfType INTEGER
  twoWireSourceChannelConnectionType INTEGER
  twoWireSourceChannelCompandingLaw INTEGER
  twoWireSourceChannelSecuFeature INTEGER
  twoWireSourceChannelVoiceCompression INTEGER
  twoWireSourceChannelEchoCancellation INTEGER
  twoWireSourceChannelSilenceSupression INTEGER
  twoWireSourceChannelEncapsulationAal INTEGER
  twoWireSourceChannelSubscriberService INTEGER

HighSpeedChannelConfigEntry  
SEQUENCE    
  highSpeedChannelId IntfIndex
  highSpeedChannelIfType INTEGER

DspChannelConfigEntry  
SEQUENCE    
  dspChannelId IntfIndex
  dspChannelIfType INTEGER
  dspChannelInputCodingRule INTEGER
  dspChannelVoiceCompression INTEGER
  dspChannelEchoCancellation INTEGER
  dspChannelSilenceSupression INTEGER

TwoWireSinkChannelConfigEntry  
SEQUENCE    
  twoWireSinkChannelId IntfIndex
  twoWireSinkChannelIfType INTEGER
  twoWireSinkChannelConnectionType INTEGER
  twoWireSinkChannelCompandingLaw INTEGER
  twoWireSinkChannelVoiceCompression INTEGER
  twoWireSinkChannelEchoCancellation INTEGER
  twoWireSinkChannelSilenceSupression INTEGER
  twoWireSinkChannelEncapsulationAal INTEGER
  twoWireSinkChannelSubscriberService INTEGER

E3ChannelConfigEntry  
SEQUENCE    
  e3ChannelId IntfIndex
  e3ChannelIfType INTEGER
  e3ChannelSecuFeature INTEGER

E1ChannelConfigEntry  
SEQUENCE    
  e1ChannelId IntfIndex
  e1ChannelIfType INTEGER
  e1ChannelDs0Map OCTET STRING
  e1ChannelCellMapping INTEGER
  e1ChannelInputCodingRule INTEGER
  e1ChannelSecuFeature INTEGER
  e1ChannelSignaling INTEGER

EthernetChannelConfigEntry  
SEQUENCE    
  ethernetChannelId Integer32
  ethernetChannelIfType INTEGER

Dsp2ChannelConfigEntry  
SEQUENCE    
  dsp2ChannelId IntfIndex
  dsp2ChannelIfType INTEGER
  dsp2ChannelAlarmType INTEGER
  dsp2ChannelModeConfig INTEGER

Dsp2AlgorithmEntry  
SEQUENCE    
  dsp2AlgorithmId IntfIndex
  dsp2AlgorithmType INTEGER

ImaGrpChannelConfigEntry  
SEQUENCE    
  imaGrpChannelId IntfIndex
  imaGrpChannelIfType INTEGER
  imaGrpChannelPortMap Integer32
  imaGrpChannelNeState ImaGrpChannelEndState
  imaGrpChannelFeState ImaGrpChannelEndState
  imaGrpChannelFailureStatus INTEGER
  imaGrpChannelSymmetry INTEGER
  imaGrpChannelMinNumTxLinks INTEGER
  imaGrpChannelMinNumRxLinks INTEGER
  imaGrpChannelNeTxClkMode INTEGER
  imaGrpChannelFeTxClkMode INTEGER
  imaGrpChannelTxImaId INTEGER
  imaGrpChannelRxImaId INTEGER
  imaGrpChannelTxFrameLength INTEGER
  imaGrpChannelRxFrameLength INTEGER
  imaGrpChannelDiffLinkDelayMax Integer32
  imaGrpChannelLeastDelayLink IntfIndex
  imaGrpChannelDiffDelayMaxObs Integer32
  imaGrpChannelAlphaValue INTEGER
  imaGrpChannelBetaValue INTEGER
  imaGrpChannelGammaValue INTEGER
  imaGrpChannelStatsNeNumFailures Integer32
  imaGrpChannelStatsFeNumFailures Integer32
  imaGrpChannelStatsNumTxActLnks Integer32
  imaGrpChannelStatsNumRxActLnks Integer32
  imaGrpChannelStatsTimer Integer32
  imaGrpChannelCompatMode INTEGER

TasmChannelConfigEntry  
SEQUENCE    
  tasmChannelId IntfIndex
  tasmChannelIfType INTEGER
  tasmChannelAlarmType INTEGER
  tasmChannelModeConfig INTEGER

AtmUniConfigEntry  
SEQUENCE    
  atmUniIfIndex IntfIndex
  atmUniAddrType INTEGER
  atmUniSvcMinVpi INTEGER
  atmUniSvcMaxVpi INTEGER
  atmUniSvcMinVci INTEGER
  atmUniSvcMaxVci INTEGER
  atmUniAdminStatus INTEGER
  atmUniOperStatus INTEGER
  atmUniOverSubscription INTEGER
  atmUniNwPrefix1 OCTET STRING
  atmUniT303 Integer32
  atmUniT308 Integer32
  atmUniT309 Integer32
  atmUniT310 Integer32
  atmUniT313 Integer32
  atmUniT316 Integer32
  atmUniT317 Integer32
  atmUniT322 Integer32
  atmUniT398 Integer32
  atmUniT399 Integer32
  atmUniMyNeighborIpAddress IpAddress
  atmUniMyNeighborIfName DisplayString
  atmUniVpiSig INTEGER
  atmUniVciSig INTEGER
  atmUniVpiIlmi INTEGER
  atmUniVciIlmi INTEGER
  atmUniAtmSignalingStatus INTEGER
  atmUniMyIfName DisplayString
  atmUniIlmiProtocolStatus INTEGER
  atmUniIlmiOperStatus INTEGER
  atmUniIlmiConfigProc INTEGER
  atmUniIlmiConnectProc INTEGER
  atmUniIlmiAttachPtProc INTEGER
  atmUniIlmiSecureLinkProc INTEGER
  atmUniIlmiAddrRegProc INTEGER
  atmUniIlmiTimerS Integer32
  atmUniIlmiTimerT Integer32
  atmUniIlmiRetryK Integer32
  atmUniIntfType INTEGER
  atmUniUserAddress OCTET STRING
  atmUniViSuppFlag INTEGER
  atmUniUPCSupp INTEGER
  atmUniUbrLoadBalSupp INTEGER
  atmUniAvailBwIgr Integer32
  atmUniAvailBwEgr Integer32
  atmUniVUNISuppFlag INTEGER
  atmUniUserAddrOrgScope INTEGER
  atmUniSscopRxWndSz INTEGER
  atmUniConnTrafficShapingFlag INTEGER

AtmIispConfigEntry  
SEQUENCE    
  atmIispIfIndex IntfIndex
  atmIispSvcMinVpi INTEGER
  atmIispSvcMaxVpi INTEGER
  atmIispSvcMinVci INTEGER
  atmIispSvcMaxVci INTEGER
  atmIispAdminStatus INTEGER
  atmIispOperStatus INTEGER
  atmIispOverSubscription INTEGER
  atmIispT303 Integer32
  atmIispT308 Integer32
  atmIispT309 Integer32
  atmIispT310 Integer32
  atmIispT316 Integer32
  atmIispT317 Integer32
  atmIispT322 Integer32
  atmIispT398 Integer32
  atmIispT399 Integer32
  atmIispAtmSignalingStatus INTEGER
  atmIispAvailBwIgr Integer32
  atmIispAvailBwEgr Integer32
  atmIispUPCSupp INTEGER
  atmIispUbrLoadBalSupp INTEGER
  atmIispSscopRxWndSz INTEGER
  atmIispConnTrafficShapingFlag INTEGER

AtmCirEmConfigEntry  
SEQUENCE    
  atmCirEmIfIndex IntfIndex
  atmCirEmAdminStatus INTEGER
  atmCirEmOperStatus INTEGER
  atmCirEmCASIdleAbcdPattern INTEGER
  atmCirEmCASBusyAbcdPattern INTEGER
  atmCirEmAlarmDataPattern INTEGER
  atmCirEmTCPattern INTEGER
  atmCirEmDownStInterworking INTEGER

AtmTermEmConfigEntry  
SEQUENCE    
  atmTermEmIfIndex IntfIndex
  atmTermEmRxTimeOut INTEGER
  atmTermEmAdminStatus INTEGER
  atmTermEmOperStatus INTEGER

HdlcConfigEntry  
SEQUENCE    
  hdlcIfIndex IntfIndex
  hdlcAdminStatus INTEGER
  hdlcOperStatus INTEGER
  hdlcThroughPut INTEGER
  hdlcDataInversion INTEGER

FrUniConfigEntry  
SEQUENCE    
  frUniIfIndex IntfIndex
  frUniAddrDlciLen INTEGER
  frUniDlcmiState INTEGER
  frUniAdminStatus INTEGER
  frUniOperStatus INTEGER
  frUniOverSubscription INTEGER
  frUniLmiProtocol INTEGER
  frUniInterworkingType INTEGER
  frUniN391 INTEGER
  frUniN392 INTEGER
  frUniN393 INTEGER
  frUniT391 INTEGER
  frUniT392 INTEGER
  frUniAsyncLmi INTEGER
  frLmiOperStatus INTEGER
  frUniNT3 INTEGER
  frUniThroughPut INTEGER

DspConfigEntry  
SEQUENCE    
  dspIfIndex IntfIndex
  dspAdminStatus INTEGER
  dspOperStatus INTEGER

BridgeConfigEntry  
SEQUENCE    
  bridgeIfIndex Integer32
  bridgeAdminStatus INTEGER
  bridgeOperStatus INTEGER
  bridgeNumber INTEGER
  bridgePortPriority INTEGER
  bridgePathCost INTEGER
  bridgeConnectionType INTEGER

BridgeDomainEntry  
SEQUENCE    
  bridgeDomainNumber Integer32
  bridgeDomainAdminStatus INTEGER
  bridgeDomainOperStatus INTEGER
  bridgeDomainPriority INTEGER
  bridgeDomainTimeSinceTopologyChange TimeTicks
  bridgeDomainDesignatedRoot OCTET STRING
  bridgeDomainRootCost Integer32
  bridgeDomainRootPort Integer32
  bridgeDomainMaxMessageAge Integer32
  bridgeDomainHelloTime Integer32
  bridgeDomainHoldTime Integer32
  bridgeDomainForwardDelay Integer32
  bridgeDomainMaxBridgeAge INTEGER
  bridgeDomainBridgeHelloTime INTEGER
  bridgeDomainBridgeForwardDelay INTEGER
  bridgeDomainAgingTime INTEGER
  bridgeDomainSpanningTree INTEGER
  bridgeDomainTopologyChanges Integer32
  bridgeDomainLearnedEntryDiscards Integer32
  bridgeDomainTimer Integer32
  bridgeDomainDefaultGateway IpAddress
  bridgeDomainPortStatusBitmap OCTET STRING

RouterConfigEntry  
SEQUENCE    
  routerIfIndex Integer32
  routerAdminStatus INTEGER
  routerOperStatus INTEGER
  routerIpAddress IpAddress
  routerIpNetworkMask IpAddress
  routerNumber INTEGER
  routerEthernetIpAddress IpAddress

IsdnIntfConfigEntry  
SEQUENCE    
  isdnIntfId Integer32
  isdnIntfDChanId Integer32
  isdnIntfAdminStatus INTEGER
  isdnIntfOperStatus INTEGER
  isdnIntfSwitchType INTEGER

IsdnL2ConfigEntry  
SEQUENCE    
  isdnL2IntfId INTEGER
  isdnT200 INTEGER
  isdnT203 INTEGER
  isdnN200 INTEGER
  isdnN201 INTEGER
  isdnK INTEGER
  isdnL2OperStatus INTEGER
  isdnL2CurrentState INTEGER

IsdnBChanConfigEntry  
SEQUENCE    
  isdnBChanId INTEGER
  isdnBChanAdminStatus INTEGER
  isdnBChanOperStatus INTEGER

AtmDbCirEmConfigEntry  
SEQUENCE    
  atmDbCirEmIfIndex IntfIndex
  atmDbCirEmAdminStatus INTEGER
  atmDbCirEmOperStatus INTEGER
  atmDbCirEmIdlePattern Integer32
  atmDbCirEmServiceType INTEGER
  atmDbCirEmDbcesType INTEGER
  atmDbCirEmIntegrationTime INTEGER

LmiDlciConfigEntry  
SEQUENCE    
  lmiDlciIfIndex IntfIndex
  lmiDlci Integer32
  lmiDlciOperStatus INTEGER
  lmiDlciStatusTime Integer32

Dsp2ConfigEntry  
SEQUENCE    
  dsp2IfIndex IntfIndex
  dsp2AdminStatus INTEGER
  dsp2OperStatus INTEGER
  dsp2LoadCount Integer32
  dsp2AalMode INTEGER

AtmImaConfigEntry  
SEQUENCE    
  atmImaIntfIndex IntfIndex
  atmImaNeTxState INTEGER
  atmImaNeRxState INTEGER
  atmImaFeTxState INTEGER
  atmImaFeRxState INTEGER
  atmImaNeRxDefect INTEGER
  atmImaFeRxDefect INTEGER
  atmImaAdminStatus INTEGER
  atmImaOperStatus INTEGER

AtmPnniConfigEntry  
SEQUENCE    
  atmPnniIfIndex IntfIndex
  atmPnniSvcMinVpi INTEGER
  atmPnniSvcMaxVpi INTEGER
  atmPnniSvcMinVci INTEGER
  atmPnniSvcMaxVci INTEGER
  atmPnniAdminStatus INTEGER
  atmPnniOperStatus INTEGER
  atmPnniT303 Integer32
  atmPnniT308 Integer32
  atmPnniT309 Integer32
  atmPnniT310 Integer32
  atmPnniT313 Integer32
  atmPnniT316 Integer32
  atmPnniT317 Integer32
  atmPnniT322 Integer32
  atmPnniT397 Integer32
  atmPnniT398 Integer32
  atmPnniT399 Integer32
  atmPnniCbrServCatSupp INTEGER
  atmPnniCbrGcacClpEqualZero INTEGER
  atmPnniCbrMaxCellRate Integer32
  atmPnniCbrAvailCellRate Integer32
  atmPnniCbrCellXerDelay Integer32
  atmPnniCbrCellLossRatioZero Integer32
  atmPnniCbrCellLossRatioZeroPlusOne Integer32
  atmPnniCbrCellDelayVar Integer32
  atmPnniRtVbrServCatSupp INTEGER
  atmPnniRtVbrGcacClpEqualZero INTEGER
  atmPnniRtVbrMaxCellRate Integer32
  atmPnniRtVbrAvailCellRate Integer32
  atmPnniRtVbrCellXerDelay Integer32
  atmPnniRtVbrCellLossRatioZero Integer32
  atmPnniRtVbrCellLossRatioZeroPlusOne Integer32
  atmPnniRtVbrCellDelayVar Integer32
  atmPnniRtVbrGcacPresent INTEGER
  atmPnniRtVbrCellRateMargin Integer32
  atmPnniRtVbrVarianceFactor Integer32
  atmPnniNrtVbrServCatSupp Integer32
  atmPnniNrtVbrGcacClpEqualZero Integer32
  atmPnniNrtVbrMaxCellRate Integer32
  atmPnniNrtVbrAvailCellRate Integer32
  atmPnniNrtVbrCellXerDelay Integer32
  atmPnniNrtVbrCellLossRatioZero Integer32
  atmPnniNrtVbrCellLossRatioZeroPlusOne Integer32
  atmPnniNrtVbrGcacPresent INTEGER
  atmPnniNrtVbrCellRateMargin Integer32
  atmPnniNrtVbrVarianceFactor Integer32
  atmPnniAbrServCatSupp Integer32
  atmPnniAbrMaxCellRate Integer32
  atmPnniAbrAvailCellRate Integer32
  atmPnniUbrServCatSupp Integer32
  atmPnniUbrMaxCellRate Integer32
  atmPnniOverSubscription INTEGER
  atmPnniSgnlEnabled INTEGER
  atmPnniVpiSig INTEGER
  atmPnniVciSig INTEGER
  atmPnniAvailBwIgr Integer32
  atmPnniAvailBwEgr Integer32
  atmPnniUPCSupp INTEGER
  atmPnniUbrLoadBalSupp INTEGER
  atmPnniSscopRxWndSz INTEGER
  atmPnniRemoteSvcMinVpi INTEGER
  atmPnniRemoteSvcMaxVpi INTEGER
  atmPnniRemoteSvcMinVci INTEGER
  atmPnniRemoteSvcMaxVci INTEGER
  atmPnniVpiIlmi INTEGER
  atmPnniVciIlmi INTEGER
  atmPnniIlmiProtocolStatus INTEGER
  atmPnniIlmiOperStatus INTEGER
  atmPnniIlmiConfigProc INTEGER
  atmPnniIlmiConnectProc INTEGER
  atmPnniIlmiAttachPtProc INTEGER
  atmPnniIlmiSecureLinkProc INTEGER
  atmPnniIlmiAddrRegProc INTEGER
  atmPnniIlmiTimerS Integer32
  atmPnniIlmiTimerT Integer32
  atmPnniIlmiRetryK Integer32
  atmPnniConnTrafficShapingFlag INTEGER

AtmVnnConfigEntry  
SEQUENCE    
  atmVnnIfIndex IntfIndex
  atmVnnAddrType INTEGER
  atmVnnSvcMinVpi INTEGER
  atmVnnSvcMaxVpi INTEGER
  atmVnnSvcMinVci INTEGER
  atmVnnSvcMaxVci INTEGER
  atmVnnAdminStatus INTEGER
  atmVnnOperStatus INTEGER
  atmVnnOverSubscription INTEGER
  atmVnnNwPrefix1 OCTET STRING
  atmVnnT303 Integer32
  atmVnnT308 Integer32
  atmVnnT309 Integer32
  atmVnnT310 Integer32
  atmVnnT313 Integer32
  atmVnnT316 Integer32
  atmVnnT317 Integer32
  atmVnnT322 Integer32
  atmVnnT398 Integer32
  atmVnnT399 Integer32
  atmVnnMyNeighborIpAddress IpAddress
  atmVnnMyNeighborIfName DisplayString
  atmVnnVpiSig INTEGER
  atmVnnVciSig INTEGER
  atmVnnVpiIlmi INTEGER
  atmVnnVciIlmi INTEGER
  atmVnnAtmSignalingStatus INTEGER
  atmVnnMyIfName DisplayString
  atmVnnIlmiProtocolStatus INTEGER
  atmVnnIlmiOperStatus INTEGER
  atmVnnIlmiConfigProc INTEGER
  atmVnnIlmiConnectProc INTEGER
  atmVnnIlmiAttachPtProc INTEGER
  atmVnnIlmiSecureLinkProc INTEGER
  atmVnnIlmiAddrRegProc INTEGER
  atmVnnIlmiTimerS Integer32
  atmVnnIlmiTimerT Integer32
  atmVnnIlmiRetryK Integer32
  atmVnnAvailBwIgr Integer32
  atmVnnAvailBwEgr Integer32
  atmVnnUPCSupp INTEGER
  atmVnnUbrLoadBalSupp INTEGER
  atmVnnSscopRxWndSz INTEGER

VirtualIntfConfigEntry  
SEQUENCE    
  virtualIntfConfigIf IntfIndex
  virtualIntfConfigVi INTEGER
  virtualIntfConfigCellRate Integer32
  virtualIntfConfigOverSubs Integer32
  virtualIntfConfigRowStatus RowStatus
  virtualIntfConfigUPCSupp INTEGER
  virtualIntfAvailBwEgr Integer32

VirtualUNIConfigEntry  
SEQUENCE    
  virtualUNIIfIndex IntfIndex
  virtualUNIVUNIId INTEGER
  virtualUNIVISupport INTEGER
  virtualUNIMinVpi INTEGER
  virtualUNIMaxVpi INTEGER
  virtualUNIConfigRowStatus RowStatus
  virtualUNIAddrType INTEGER
  virtualUNISvcMinVpi INTEGER
  virtualUNISvcMaxVpi INTEGER
  virtualUNISvcMinVci INTEGER
  virtualUNISvcMaxVci INTEGER
  virtualUNIAdminStatus INTEGER
  virtualUNIOperStatus INTEGER
  virtualUNINwPrefix1 OCTET STRING
  virtualUNIT303 Integer32
  virtualUNIT308 Integer32
  virtualUNIT309 Integer32
  virtualUNIT310 Integer32
  virtualUNIT313 Integer32
  virtualUNIT316 Integer32
  virtualUNIT317 Integer32
  virtualUNIT322 Integer32
  virtualUNIT398 Integer32
  virtualUNIT399 Integer32
  virtualUNIMyNeighborIpAddress IpAddress
  virtualUNIMyNeighborIfName DisplayString
  virtualUNIVpiSig INTEGER
  virtualUNIVciSig INTEGER
  virtualUNISignalingAdminStatus INTEGER
  virtualUNISignalingOperStatus INTEGER
  virtualUNIVpiIlmi INTEGER
  virtualUNIVciIlmi INTEGER
  virtualUNIMyIfName DisplayString
  virtualUNIIlmiProtocolStatus INTEGER
  virtualUNIIlmiOperStatus INTEGER
  virtualUNIIlmiConfigProc INTEGER
  virtualUNIIlmiConnectProc INTEGER
  virtualUNIIlmiAttachPtProc INTEGER
  virtualUNIIlmiSecureLinkProc INTEGER
  virtualUNIIlmiAddrRegProc INTEGER
  virtualUNIIlmiTimerS Integer32
  virtualUNIIlmiTimerT Integer32
  virtualUNIIlmiRetryK Integer32
  virtualUNIIntfType INTEGER
  virtualUNIUserAddress OCTET STRING
  virtualUNIUserAddrOrgScope INTEGER
  virtualUNISscopRxWndSz INTEGER

CasConfigEntry  
SEQUENCE    
  casIfIndex IntfIndex
  casAdminStatus INTEGER
  casOperStatus INTEGER
  casProtocolType INTEGER
  casDirection INTEGER
  casAddressingType INTEGER
  casBitPatternType INTEGER
  casGroupId INTEGER

ToneAnnceConfigEntry  
SEQUENCE    
  toneAnnceIfIndex IntfIndex
  toneAnnceAdminStatus INTEGER
  toneAnnceOperStatus INTEGER

Gr303IntfConfigEntry  
SEQUENCE    
  gr303IntfId Integer32
  gr303TMCChannelId Integer32
  gr303EOCChannelId Integer32
  gr303IntfAdminStatus INTEGER
  gr303IntfOperStatus INTEGER

Gr303Ds0ChanConfigEntry  
SEQUENCE    
  gr303Ds0ChanId INTEGER
  gr303Ds0ChanAdminStatus INTEGER
  gr303Ds0ChanOperStatus INTEGER

Gr303IgConfigEntry  
SEQUENCE    
  gr303IgId INTEGER
  gr303IgRowStatus RowStatus
  gr303IgAdminStatus INTEGER
  gr303IgPrimaryTMCChanIntfId IntfIndex
  gr303IgPrimaryEOCChanIntfId IntfIndex
  gr303IgBackupTMCChanIntfId IntfIndex
  gr303IgBackupEOCChanIntfId IntfIndex
  gr303IgPrimaryTMCStatus INTEGER
  gr303IgPrimaryEOCStatus INTEGER
  gr303IgBackupTMCStatus INTEGER
  gr303IgBackupEOCStatus INTEGER
  gr303IgTMCProtSwitchProvState INTEGER
  gr303IgEOCProtSwitchProvState INTEGER
  gr303IgTMCProtSwitchCommand INTEGER
  gr303IgEOCProtSwitchCommand INTEGER
  gr303IgLocalDigitalSwitchType INTEGER
  gr303IgLocalDigitalSwitchVersion INTEGER

Gr303IgIntfConfigEntry  
SEQUENCE    
  gr303IntfIgId INTEGER
  gr303IgIntfId INTEGER
  gr303IgIntfPhysId INTEGER
  gr303IgIntfNetId INTEGER
  gr303IgIntfRowStatus RowStatus

Gr303LapdConfigEntry  
SEQUENCE    
  gr303LapdIgId INTEGER
  gr303T200 Integer32
  gr303T203 Integer32
  gr303N200 Integer32
  gr303K Integer32

Gr303TMCConfigEntry  
SEQUENCE    
  gr303TMCIgId INTEGER
  gr303TMCT303 INTEGER
  gr303TMCT396 INTEGER

Gr303IgStatsEntry  
SEQUENCE    
  gr303IgStatsIgId INTEGER
  gr303IgStatsCurrentInCalls Integer32
  gr303IgStatsCurrentOutCalls Integer32
  gr303IgStatsOutCallSuccessful Integer32
  gr303IgStatsOutCallFailed Integer32
  gr303IgStatsInCallSuccessful Integer32
  gr303IgStatsInCallFailed Integer32
  gr303IgStatsReset INTEGER

AtmPvcVccEntry  
SEQUENCE    
  atmPvcVccIfA IntfIndex
  atmPvcVccVpiA INTEGER
  atmPvcVccVciA INTEGER
  atmPvcVccIfB IntfIndex
  atmPvcVccVpiB INTEGER
  atmPvcVccVciB INTEGER
  atmPvcVccServiceTypeA2B INTEGER
  atmPvcVccSarTypeA2B INTEGER
  atmPvcVccPeakCellRateA2B Integer32
  atmPvcVccSusCellRateA2B Integer32
  atmPvcVccMaxBurstSizeA2B Integer32
  atmPvcVccServiceTypeB2A INTEGER
  atmPvcVccSarTypeB2A INTEGER
  atmPvcVccPeakCellRateB2A Integer32
  atmPvcVccSusCellRateB2A Integer32
  atmPvcVccMaxBurstSizeB2A Integer32
  atmPvcVccType INTEGER
  atmPvcVccFlow INTEGER
  atmPvcVccRowStatus RowStatus
  atmPvcVccFrwdErrCorrectionA2B INTEGER
  atmPvcVccFrwdErrCorrectionB2A INTEGER
  atmPvcVccConnectionStatus INTEGER
  atmPvcVccOamStatus INTEGER
  atmPvcVccDualHomed INTEGER
  atmPvcVccViA INTEGER
  atmPvcVccViB INTEGER
  atmPvcVccCnfrmTypeA2B INTEGER
  atmPvcVccCnfrmTypeB2A INTEGER
  atmPvcVccVUNIA INTEGER
  atmPvcVccVUNIB INTEGER
  atmPvcVccOamStatusB INTEGER
  atmPvcVccOAMConnEndPtStatusA INTEGER
  atmPvcVccOAMConnEndPtStatusB INTEGER
  atmPvcVccOAMConnSegEndPtStatusA INTEGER
  atmPvcVccOAMConnSegEndPtStatusB INTEGER
  atmPvcVccMfsA2B INTEGER
  atmPvcVccMfsB2A INTEGER
  atmPvcVccConnFailureCauseA AtmConnFailureCause
  atmPvcVccConnFailureCauseB AtmConnFailureCause
  atmPvcVccTrafficShapingA2B INTEGER
  atmPvcVccTrafficShapingB2A INTEGER

AtmPvcVpcEntry  
SEQUENCE    
  atmPvcVpcIfA IntfIndex
  atmPvcVpcVpiA INTEGER
  atmPvcVpcIfB IntfIndex
  atmPvcVpcVpiB INTEGER
  atmPvcVpcServiceTypeA2B INTEGER
  atmPvcVpcSarTypeA2B INTEGER
  atmPvcVpcPeakCellRateA2B Integer32
  atmPvcVpcSusCellRateA2B Integer32
  atmPvcVpcMaxBurstSizeA2B Integer32
  atmPvcVpcServiceTypeB2A INTEGER
  atmPvcVpcSarTypeB2A INTEGER
  atmPvcVpcPeakCellRateB2A Integer32
  atmPvcVpcSusCellRateB2A Integer32
  atmPvcVpcMaxBurstSizeB2A Integer32
  atmPvcVpcType INTEGER
  atmPvcVpcFlow INTEGER
  atmPvcVpcRowStatus RowStatus
  atmPvcVpcConnectionStatus INTEGER
  atmPvcVpcOamStatus INTEGER
  atmPvcVpcDualHomed INTEGER
  atmPvcVpcViA INTEGER
  atmPvcVpcViB INTEGER
  atmPvcVpcCnfrmTypeA2B INTEGER
  atmPvcVpcCnfrmTypeB2A INTEGER
  atmPvcVpcVUNIA INTEGER
  atmPvcVpcVUNIB INTEGER
  atmPvcVpcOamStatusB INTEGER
  atmPvcVpcOAMConnEndPtStatusA INTEGER
  atmPvcVpcOAMConnEndPtStatusB INTEGER
  atmPvcVpcOAMConnSegEndPtStatusA INTEGER
  atmPvcVpcOAMConnSegEndPtStatusB INTEGER
  atmPvcVpcConnFailureCauseA AtmConnFailureCause
  atmPvcVpcConnFailureCauseB AtmConnFailureCause
  atmPvcVpcTrafficShapingA2B INTEGER
  atmPvcVpcTrafficShapingB2A INTEGER

AtmSvcVccEntry  
SEQUENCE    
  atmSvcVccIfA IntfIndex
  atmSvcVccVpiA INTEGER
  atmSvcVccVciA INTEGER
  atmSvcVccIfB IntfIndex
  atmSvcVccVpiB INTEGER
  atmSvcVccVciB INTEGER
  atmSvcVccServiceTypeA2B INTEGER
  atmSvcVccSarTypeA2B INTEGER
  atmSvcVccPeakCellRateA2B Integer32
  atmSvcVccSusCellRateA2B Integer32
  atmSvcVccMaxBurstSizeA2B Integer32
  atmSvcVccServiceTypeB2A INTEGER
  atmSvcVccSarTypeB2A INTEGER
  atmSvcVccPeakCellRateB2A Integer32
  atmSvcVccSusCellRateB2A Integer32
  atmSvcVccMaxBurstSizeB2A Integer32
  atmSvcVccFlow INTEGER
  atmSvcVccType INTEGER
  atmSvcVccConnectionStatus INTEGER
  atmSvcVccViA INTEGER
  atmSvcVccViB INTEGER
  atmSvcVccCnfrmTypeA2B INTEGER
  atmSvcVccCnfrmTypeB2A INTEGER
  atmSvcVccVUNIA INTEGER
  atmSvcVccVUNIB INTEGER
  atmSvcVccTrafficShapingA2B INTEGER
  atmSvcVccTrafficShapingB2A INTEGER

IpAtmAppPvcVccEntry  
SEQUENCE    
  ipAtmAppPvcVccDestAddrA IpAddress
  ipAtmAppPvcVccSubnetMaskA IpAddress
  ipAtmAppPvcVccIfB Integer32
  ipAtmAppPvcVccVpiB INTEGER
  ipAtmAppPvcVccVciB INTEGER
  ipAtmAppPvcVccServiceTypeA2B INTEGER
  ipAtmAppPvcVccServiceTypeB2A INTEGER
  ipAtmAppPvcVccPeakCellRateB2A Integer32
  ipAtmAppPvcVccSusCellRateB2A Integer32
  ipAtmAppPvcVccMaxBurstSizeB2A Integer32
  ipAtmAppPvcVccType INTEGER
  ipAtmAppPvcVccRowStatus RowStatus
  ipAtmAppPvcVccConnectionStatus INTEGER
  ipAtmAppPvcVccDualHomed INTEGER
  ipAtmAppPvcVccViB INTEGER
  ipAtmAppPvcVccCnfrmTypeB2A INTEGER
  ipAtmAppPvcVccVUNIB INTEGER
  ipAtmAppPvcVccMfsB2A INTEGER
  ipAtmAppPvcVccConnFailureCauseB AtmConnFailureCause
  ipAtmAppPvcVccTrafficShapingA2B INTEGER
  ipAtmAppPvcVccOamStatus INTEGER

IpAtmAppSvcVccEntry  
SEQUENCE    
  ipAtmAppSvcVccDestAddrA IpAddress
  ipAtmAppSvcVccSubnetMaskA IpAddress
  ipAtmAppSvcVccIfB Integer32
  ipAtmAppSvcVccVpiB INTEGER
  ipAtmAppSvcVccVciB INTEGER
  ipAtmAppSvcVccServiceTypeA2B INTEGER
  ipAtmAppSvcVccServiceTypeB2A INTEGER
  ipAtmAppSvcVccPeakCellRateB2A Integer32
  ipAtmAppSvcVccSusCellRateB2A Integer32
  ipAtmAppSvcVccMaxBurstSizeB2A Integer32
  ipAtmAppSvcVccType INTEGER
  ipAtmAppSvcVccConnectionStatus INTEGER
  ipAtmAppSvcVccViB INTEGER
  ipAtmAppSvcVccCnfrmTypeB2A INTEGER
  ipAtmAppSvcVccVUNIB INTEGER
  ipAtmAppSvcVccTrafficShapingA2B INTEGER

CirEmAtmPvcVccEntry  
SEQUENCE    
  cirEmAtmPvcVccIfA IntfIndex
  cirEmAtmPvcVccIfB IntfIndex
  cirEmAtmPvcVccVpiB INTEGER
  cirEmAtmPvcVccVciB INTEGER
  cirEmAtmPvcVccServiceType INTEGER
  cirEmAtmPvcVccVoiceCompressionA2B INTEGER
  cirEmAtmPvcVccSilenceDetectionA2B INTEGER
  cirEmAtmPvcVccEchoCancellationA2B INTEGER
  cirEmAtmPvcVccFlow INTEGER
  cirEmAtmPvcVccRowStatus RowStatus
  cirEmAtmPvcVccCngToneDetectionA2B INTEGER
  cirEmAtmPvcVccCodingTranslationA2B INTEGER
  cirEmAtmPvcVccVoiceCompressionB2A INTEGER
  cirEmAtmPvcVccSilenceDetectionB2A INTEGER
  cirEmAtmPvcVccEchoCancellationB2A INTEGER
  cirEmAtmPvcVccCngToneDetectionB2A INTEGER
  cirEmAtmPvcVccCodingTranslationB2A INTEGER
  cirEmAtmPvcVccSarTypeB INTEGER
  cirEmAtmPvcVccConnectionStatus INTEGER
  cirEmAtmPvcVccDualHomed INTEGER
  cirEmAtmPvcVccOamStatus INTEGER
  cirEmAtmPvcVccViB INTEGER
  cirEmAtmPvcVccCnfrmTypeB2A INTEGER
  cirEmAtmPvcVccVUNIB INTEGER
  cirEmAtmPvcVccAal2Cid INTEGER
  cirEmAtmPvcVccOAMConnEndPtStatus INTEGER
  cirEmAtmPvcVccOAMConnSegEndPtStatus INTEGER
  cirEmAtmPvcVccConnFailureCauseA ConnFailureCause
  cirEmAtmPvcVccConnFailureCauseB AtmConnFailureCause
  cirEmAtmPvcVccDigitCollectTypeA2B INTEGER
  cirEmAtmPvcVccDigitCollectTypeB2A INTEGER
  cirEmAtmPvcVccEncodingStdA2B INTEGER
  cirEmAtmPvcVccEncodingStdB2A INTEGER
  cirEmAtmPvcVccEncodingProfileIdA2B INTEGER
  cirEmAtmPvcVccEncodingProfileIdB2A INTEGER

FrAtmPvcVccEntry  
SEQUENCE    
  frAtmPvcVccIfA IntfIndex
  frAtmPvcVccDlciA Integer32
  frAtmPvcVccIfB IntfIndex
  frAtmPvcVccVpiB INTEGER
  frAtmPvcVccVciB INTEGER
  frAtmPvcVccMaxFrameSizeIn Integer32
  frAtmPvcVccBcIn Integer32
  frAtmPvcVccBeIn Integer32
  frAtmPvcVccCirIn Integer32
  frAtmPvcVccMaxFrameSizeOut Integer32
  frAtmPvcVccBcOut Integer32
  frAtmPvcVccBeOut Integer32
  frAtmPvcVccCirOut Integer32
  frAtmPvcVccServiceType INTEGER
  frAtmPvcVccFlow INTEGER
  frAtmPvcVccRowStatus RowStatus
  frAtmPvcVccTimeLenIn INTEGER
  frAtmPvcVccInterWorkingFuncIn INTEGER
  frAtmPvcVccTimeLenOut INTEGER
  frAtmPvcVccInterWorkingFuncOut INTEGER
  frAtmPvcVccPeakCellRateA2B Integer32
  frAtmPvcVccSusCellRateA2B Integer32
  frAtmPvcVccMaxBurstSizeA2B Integer32
  frAtmPvcVccPeakCellRateB2A Integer32
  frAtmPvcVccSusCellRateB2A Integer32
  frAtmPvcVccMaxBurstSizeB2A Integer32
  frAtmPvcVccConnectionStatus INTEGER
  frAtmPvcVccDualHomed INTEGER
  frAtmPvcVccOamStatus INTEGER
  frAtmPvcVccViB INTEGER
  frAtmPvcVccCnfrmTypeB2A INTEGER
  frAtmPvcVccVUNIB INTEGER
  frAtmPvcVccOAMConnEndPtStatus INTEGER
  frAtmPvcVccOAMSegEndPtStatus INTEGER
  frAtmPvcVccMfsB2A INTEGER
  frAtmPvcVccConnFailureCauseA FrConnFailureCause
  frAtmPvcVccConnFailureCauseB AtmConnFailureCause
  frAtmPvcVccTrafficShapingA2B INTEGER

FrFrPvcEntry  
SEQUENCE    
  frFrPvcIfA IntfIndex
  frFrPvcDlciA Integer32
  frFrPvcIfB IntfIndex
  frFrPvcDlciB Integer32
  frFrPvcMaxFrameSizeA2B Integer32
  frFrPvcBcA2B Integer32
  frFrPvcBeA2B Integer32
  frFrPvcCirA2B Integer32
  frFrPvcMaxFrameSizeB2A Integer32
  frFrPvcBcB2A Integer32
  frFrPvcBeB2A Integer32
  frFrPvcCirB2A Integer32
  frFrPvcServiceType INTEGER
  frFrPvcFlow INTEGER
  frFrPvcRowStatus RowStatus
  frFrPvcTimeLenA2B INTEGER
  frFrPvcInterWorkingFuncA2B INTEGER
  frFrPvcTimeLenB2A INTEGER
  frFrPvcInterWorkingFuncB2A INTEGER
  frFrPvcPeakCellRateA2B Integer32
  frFrPvcSusCellRateA2B Integer32
  frFrPvcMaxBurstSizeA2B Integer32
  frFrPvcPeakCellRateB2A Integer32
  frFrPvcSusCellRateB2A Integer32
  frFrPvcMaxBurstSizeB2A Integer32
  frFrPvcConnectionStatus INTEGER
  frFrPvcConnFailureCauseA FrConnFailureCause
  frFrPvcConnFailureCauseB FrConnFailureCause

VbrAtmPvcVccEntry  
SEQUENCE    
  vbrAtmPvcVccIfA IntfIndex
  vbrAtmPvcVccIfB IntfIndex
  vbrAtmPvcVccVpiB INTEGER
  vbrAtmPvcVccVciB INTEGER
  vbrAtmPvcVccServiceType INTEGER
  vbrAtmPvcVccPeakCellRateA2B Integer32
  vbrAtmPvcVccSusCellRateA2B Integer32
  vbrAtmPvcVccMaxBurstSizeA2B Integer32
  vbrAtmPvcVccPeakCellRateB2A Integer32
  vbrAtmPvcVccSusCellRateB2A Integer32
  vbrAtmPvcVccMaxBurstSizeB2A Integer32
  vbrAtmPvcVccFlow INTEGER
  vbrAtmPvcVccRowStatus RowStatus
  vbrAtmPvcVccConnectionStatus INTEGER
  vbrAtmPvcVccDualHomed INTEGER
  vbrAtmPvcVccOamStatus INTEGER
  vbrAtmPvcVccViB INTEGER
  vbrAtmPvcVccCnfrmTypeB2A INTEGER
  vbrAtmPvcVccVUNIB INTEGER
  vbrAtmPvcVccOAMConnEndPtStatus INTEGER
  vbrAtmPvcVccOAMSegEndPtStatus INTEGER
  vbrAtmPvcVccMfsB2A INTEGER
  vbrAtmPvcVccConnFailureCauseA ConnFailureCause
  vbrAtmPvcVccConnFailureCauseB AtmConnFailureCause
  vbrAtmPvcVccSarTypeB INTEGER
  vbrAtmPvcVccAal2Cid INTEGER
  vbrAtmPvcVccTrafficShapingA2B INTEGER

CirEmCirEmPvcEntry  
SEQUENCE    
  cirEmCirEmPvcIfA IntfIndex
  cirEmCirEmPvcIfB IntfIndex
  cirEmCirEmPvcEchoCancellationA2B INTEGER
  cirEmCirEmPvcFlow INTEGER
  cirEmCirEmPvcRowStatus RowStatus
  cirEmCirEmPvcCodingTranslationA2B INTEGER
  cirEmCirEmPvcEchoCancellationB2A INTEGER
  cirEmCirEmPvcCodingTranslationB2A INTEGER
  cirEmCirEmPvcConnectionStatus INTEGER
  cirEmCirEmPvcInterworking INTEGER
  cirEmCirEmPvcServiceType INTEGER
  cirEmCirEmPvcConnFailureCauseA ConnFailureCause
  cirEmCirEmPvcConnFailureCauseB ConnFailureCause

VbrVbrPvcEntry  
SEQUENCE    
  vbrVbrPvcIfA IntfIndex
  vbrVbrPvcIfB IntfIndex
  vbrVbrPvcPeakCellRateA2B Integer32
  vbrVbrPvcSusCellRateA2B Integer32
  vbrVbrPvcMaxBurstSizeA2B Integer32
  vbrVbrPvcPeakCellRateB2A Integer32
  vbrVbrPvcSusCellRateB2A Integer32
  vbrVbrPvcMaxBurstSizeB2A Integer32
  vbrVbrPvcFlow INTEGER
  vbrVbrPvcRowStatus RowStatus
  vbrVbrPvcConnectionStatus INTEGER
  vbrVbrPvcServiceType INTEGER
  vbrVbrPvcConnFailureCauseA ConnFailureCause
  vbrVbrPvcConnFailureCauseB ConnFailureCause

BridgeBridgePvcEntry  
SEQUENCE    
  bridgeBridgePvcIfA Integer32
  bridgeBridgePvcIfB Integer32
  bridgeBridgePvcRowStatus RowStatus
  bridgeBridgePvcConnectionStatus INTEGER
  bridgeBridgePvcConnFailureCauseA ConnFailureCause
  bridgeBridgePvcConnFailureCauseB ConnFailureCause

BridgeAtmPvcVccEntry  
SEQUENCE    
  bridgeAtmPvcVccIfA Integer32
  bridgeAtmPvcVccIfB Integer32
  bridgeAtmPvcVccVpiB INTEGER
  bridgeAtmPvcVccVciB INTEGER
  bridgeAtmPvcVccServiceType INTEGER
  bridgeAtmPvcVccPeakCellRateB2A Integer32
  bridgeAtmPvcVccSusCellRateB2A Integer32
  bridgeAtmPvcVccMaxBurstSizeB2A Integer32
  bridgeAtmPvcVccRowStatus RowStatus
  bridgeAtmPvcVccConnectionStatus INTEGER
  bridgeAtmPvcVccDualHomed INTEGER
  bridgeAtmPvcVccViB INTEGER
  bridgeAtmPvcVccCnfrmTypeB2A INTEGER
  bridgeAtmPvcVccVUNIB INTEGER
  bridgeAtmPvcVccMfsB2A INTEGER
  bridgeAtmPvcVccConnFailureCauseA ConnFailureCause
  bridgeAtmPvcVccConnFailureCauseB AtmConnFailureCause
  bridgeAtmPvcVccOamStatus INTEGER
  bridgeAtmPvcVccTrafficShapingA2B INTEGER

CirEmAtmBkPvcVccEntry  
SEQUENCE    
  cirEmAtmBkPvcVccIfB IntfIndex
  cirEmAtmBkPvcVccVpiB INTEGER
  cirEmAtmBkPvcVccVciB INTEGER
  cirEmAtmBkPvcVccActivePvc INTEGER
  cirEmAtmBkPvcVccAutoSwitch INTEGER
  cirEmAtmBkPvcVccRowStatus RowStatus
  cirEmAtmBkPvcVccViB INTEGER
  cirEmAtmBkPvcVccVUNIB INTEGER
  cirEmAtmBkPvcVccConnFailureCauseB AtmConnFailureCause

VbrAtmBkPvcVccEntry  
SEQUENCE    
  vbrAtmBkPvcVccIfB IntfIndex
  vbrAtmBkPvcVccVpiB INTEGER
  vbrAtmBkPvcVccVciB INTEGER
  vbrAtmBkPvcVccActivePvc INTEGER
  vbrAtmBkPvcVccAutoSwitch INTEGER
  vbrAtmBkPvcVccRowStatus RowStatus
  vbrAtmBkPvcVccViB INTEGER
  vbrAtmBkPvcVccVUNIB INTEGER
  vbrAtmBkPvcVccConnFailureCauseB AtmConnFailureCause

AtmSpvcVccAddrEntry  
SEQUENCE    
  atmSpvcVccIfA IntfIndex
  atmSpvcVccAtmPortAddr OCTET STRING
  atmSpvcVccAddrRowStatus RowStatus

AtmSpvcVccEntry  
SEQUENCE    
  atmSpvcVccVpiA INTEGER
  atmSpvcVccVciA INTEGER
  atmSpvcVccIfB IntfIndex
  atmSpvcVccVpiB INTEGER
  atmSpvcVccVciB INTEGER
  atmSpvcVccServiceTypeA2B INTEGER
  atmSpvcVccSarTypeA2B INTEGER
  atmSpvcVccPeakCellRateA2B Integer32
  atmSpvcVccSusCellRateA2B Integer32
  atmSpvcVccMaxBurstSizeA2B Integer32
  atmSpvcVccFrwdErrCorrectionA2B INTEGER
  atmSpvcVccServiceTypeB2A INTEGER
  atmSpvcVccSarTypeB2A INTEGER
  atmSpvcVccPeakCellRateB2A Integer32
  atmSpvcVccSusCellRateB2A Integer32
  atmSpvcVccMaxBurstSizeB2A Integer32
  atmSpvcVccFrwdErrCorrectionB2A INTEGER
  atmSpvcVccFlow INTEGER
  atmSpvcVccType INTEGER
  atmSpvcVccConnType INTEGER
  atmSpvcVccLeafReference INTEGER
  atmSpvcVccOperStatus INTEGER
  atmSpvcVccRowStatus RowStatus
  atmSpvcVccViA INTEGER
  atmSpvcVccViB INTEGER
  atmSpvcVccTrafficShapingA2B INTEGER
  atmSpvcVccTrafficShapingB2A INTEGER

AtmSpvcVccActiveSvcEntry  
SEQUENCE    
  atmSpvcVccRemoteAtmPortAddr OCTET STRING
  atmSpvcVccRemoteSelectType INTEGER
  atmSpvcVccRemoteVpi INTEGER
  atmSpvcVccRemoteVci INTEGER
  atmSpvcVccRetryInterval INTEGER
  atmSpvcVccRetryLimit INTEGER
  atmSpvcVccRestart INTEGER
  atmSpvcVccRetryFailure Integer32
  atmSpvcVccReleaseCause INTEGER
  atmSpvcVccReleaseDiag OCTET STRING

CirEmAtmSpvcVccEntry  
SEQUENCE    
  cirEmAtmSpvcVccIfA IntfIndex
  cirEmAtmSpvcVccIfB IntfIndex
  cirEmAtmSpvcVccVpiB INTEGER
  cirEmAtmSpvcVccVciB INTEGER
  cirEmAtmSpvcVccVoiceCompressionA2B INTEGER
  cirEmAtmSpvcVccSilenceDetectionA2B INTEGER
  cirEmAtmSpvcVccEchoCancellationA2B INTEGER
  cirEmAtmSpvcVccCngToneDetectionA2B INTEGER
  cirEmAtmSpvcVccCodingTranslationA2B INTEGER
  cirEmAtmSpvcVccVoiceCompressionB2A INTEGER
  cirEmAtmSpvcVccSilenceDetectionB2A INTEGER
  cirEmAtmSpvcVccEchoCancellationB2A INTEGER
  cirEmAtmSpvcVccCngToneDetectionB2A INTEGER
  cirEmAtmSpvcVccCodingTranslationB2A INTEGER
  cirEmAtmSpvcVccFlow INTEGER
  cirEmAtmSpvcVccServiceType INTEGER
  cirEmAtmSpvcVccConnType INTEGER
  cirEmAtmSpvcVccCePortAddr OCTET STRING
  cirEmAtmSpvcVccOperStatus INTEGER
  cirEmAtmSpvcVccRowStatus RowStatus
  cirEmAtmSpvcVccViB INTEGER

CirEmAtmSpvcVccActiveSvcEntry  
SEQUENCE    
  cirEmAtmSpvcVccRemoteCePortAddr OCTET STRING
  cirEmAtmSpvcVccRetryInterval INTEGER
  cirEmAtmSpvcVccRetryLimit INTEGER
  cirEmAtmSpvcVccRestart INTEGER
  cirEmAtmSpvcVccRetryFailure Integer32
  cirEmAtmSpvcVccReleaseCause INTEGER
  cirEmAtmSpvcVccReleaseDiag OCTET STRING

VbrAtmSpvcVccEntry  
SEQUENCE    
  vbrAtmSpvcVccIfA IntfIndex
  vbrAtmSpvcVccIfB IntfIndex
  vbrAtmSpvcVccVpiB INTEGER
  vbrAtmSpvcVccVciB INTEGER
  vbrAtmSpvcVccServiceType INTEGER
  vbrAtmSpvcVccPeakCellRateA2B Integer32
  vbrAtmSpvcVccSusCellRateA2B Integer32
  vbrAtmSpvcVccMaxBurstSizeA2B Integer32
  vbrAtmSpvcVccPeakCellRateB2A Integer32
  vbrAtmSpvcVccSusCellRateB2A Integer32
  vbrAtmSpvcVccMaxBurstSizeB2A Integer32
  vbrAtmSpvcVccFlow INTEGER
  vbrAtmSpvcVccConnType INTEGER
  vbrAtmSpvcVccVbrPortAddr OCTET STRING
  vbrAtmSpvcVccOperStatus INTEGER
  vbrAtmSpvcVccRowStatus RowStatus
  vbrAtmSpvcVccViB INTEGER
  vbrAtmSpvcVccTrafficShapingA2B INTEGER

VbrAtmSpvcVccActiveSvcEntry  
SEQUENCE    
  vbrAtmSpvcVccRemoteVbrPortAddr OCTET STRING
  vbrAtmSpvcVccRetryInterval INTEGER
  vbrAtmSpvcVccRetryLimit INTEGER
  vbrAtmSpvcVccRestart INTEGER
  vbrAtmSpvcVccRetryFailure Integer32
  vbrAtmSpvcVccReleaseCause INTEGER
  vbrAtmSpvcVccReleaseDiag OCTET STRING

AtmSpvcVccRlsEntry  
SEQUENCE    
  atmSpvcVccRelease INTEGER

CirEmAtmSpvcVccRlsEntry  
SEQUENCE    
  cirEmAtmSpvcVccRelease INTEGER

VbrAtmSpvcVccRlsEntry  
SEQUENCE    
  vbrAtmSpvcVccRelease INTEGER

FrAtmBkPvcVccEntry  
SEQUENCE    
  frAtmBkPvcVccIfB IntfIndex
  frAtmBkPvcVccVpiB INTEGER
  frAtmBkPvcVccVciB INTEGER
  frAtmBkPvcVccActivePvc INTEGER
  frAtmBkPvcVccAutoSwitch INTEGER
  frAtmBkPvcVccRowStatus RowStatus
  frAtmBkPvcVccViB INTEGER
  frAtmBkPvcVccVUNIB INTEGER
  frAtmBkPvcVccConnFailureCauseB AtmConnFailureCause

AtmBkPvcVccEntry  
SEQUENCE    
  atmBkPvcVccIfB IntfIndex
  atmBkPvcVccVpiB INTEGER
  atmBkPvcVccVciB INTEGER
  atmBkPvcVccActivePvc INTEGER
  atmBkPvcVccAutoSwitch INTEGER
  atmBkPvcVccRowStatus RowStatus
  atmBkPvcVccViB INTEGER
  atmBkPvcVccVUNIB INTEGER
  atmBkPvcVccConnFailureCauseB AtmConnFailureCause

AtmBkPvcVpcEntry  
SEQUENCE    
  atmBkPvcVpcIfB IntfIndex
  atmBkPvcVpcVpiB INTEGER
  atmBkPvcVpcActivePvc INTEGER
  atmBkPvcVpcAutoSwitch INTEGER
  atmBkPvcVpcRowStatus RowStatus
  atmBkPvcVpcViB INTEGER
  atmBkPvcVpcVUNIB INTEGER
  atmBkPvcVpcConnFailureCauseB AtmConnFailureCause

BridgeAtmBkPvcVccEntry  
SEQUENCE    
  bridgeAtmBkPvcVccIfB IntfIndex
  bridgeAtmBkPvcVccVpiB INTEGER
  bridgeAtmBkPvcVccVciB INTEGER
  bridgeAtmBkPvcVccActivePvc INTEGER
  bridgeAtmBkPvcVccAutoSwitch INTEGER
  bridgeAtmBkPvcVccRowStatus RowStatus
  bridgeAtmBkPvcVccViB INTEGER
  bridgeAtmBkPvcVccVUNIB INTEGER
  bridgeAtmBkPvcVccConnFailureCauseB AtmConnFailureCause

IpAtmBkAppPvcVccEntry  
SEQUENCE    
  ipAtmBkAppPvcVccIfB IntfIndex
  ipAtmBkAppPvcVccVpiB INTEGER
  ipAtmBkAppPvcVccVciB INTEGER
  ipAtmBkAppPvcVccActivePvc INTEGER
  ipAtmBkAppPvcVccAutoSwitch INTEGER
  ipAtmBkAppPvcVccRowStatus RowStatus
  ipAtmBkAppPvcVccViB INTEGER
  ipAtmBkAppPvcVccVUNIB INTEGER
  ipAtmBkAppPvcVccConnFailureCauseB AtmConnFailureCause

SpvcAddrEntry  
SEQUENCE    
  spvcAddrIfA IntfIndex
  spvcAddrLocalPortAddr OCTET STRING
  spvcAddrRowStatus RowStatus

FrAtmSpvcVccEntry  
SEQUENCE    
  frAtmSpvcVccDlciA Integer32
  frAtmSpvcVccIfB IntfIndex
  frAtmSpvcVccVpiB INTEGER
  frAtmSpvcVccVciB INTEGER
  frAtmSpvcVccMaxFrameSizeIn Integer32
  frAtmSpvcVccBcIn Integer32
  frAtmSpvcVccBeIn Integer32
  frAtmSpvcVccCirIn Integer32
  frAtmSpvcVccMaxFrameSizeOut Integer32
  frAtmSpvcVccBcOut Integer32
  frAtmSpvcVccBeOut Integer32
  frAtmSpvcVccCirOut Integer32
  frAtmSpvcVccServiceType INTEGER
  frAtmSpvcVccFlow INTEGER
  frAtmSpvcVccTimeLenIn INTEGER
  frAtmSpvcVccTimeLenOut INTEGER
  frAtmSpvcVccPeakCellRateA2B Integer32
  frAtmSpvcVccSusCellRateA2B Integer32
  frAtmSpvcVccMaxBurstSizeA2B Integer32
  frAtmSpvcVccPeakCellRateB2A Integer32
  frAtmSpvcVccSusCellRateB2A Integer32
  frAtmSpvcVccMaxBurstSizeB2A Integer32
  frAtmSpvcVccInterWorkingFunc INTEGER
  frAtmSpvcVccConnType INTEGER
  frAtmSpvcVccOperStatus INTEGER
  frAtmSpvcVccRowStatus RowStatus
  frAtmSpvcVccRemoteFrPortAddr OCTET STRING
  frAtmSpvcVccRemoteSelectType INTEGER
  frAtmSpvcVccRemoteDlci INTEGER
  frAtmSpvcVccRemoteVpi INTEGER
  frAtmSpvcVccRemoteVci INTEGER
  frAtmSpvcVccRetryInterval INTEGER
  frAtmSpvcVccRetryLimit INTEGER
  frAtmSpvcVccRestart INTEGER
  frAtmSpvcVccRetryFailure Integer32
  frAtmSpvcVccReleaseCause INTEGER
  frAtmSpvcVccReleaseDiag OCTET STRING
  frAtmSpvcVccRelease INTEGER
  frAtmSpvcVccStatsCellsEncodedHiA Integer32
  frAtmSpvcVccStatsCellsEncodedLoA Integer32
  frAtmSpvcVccStatsCellsDecodedHiA Integer32
  frAtmSpvcVccStatsCellsDecodedLoA Integer32
  frAtmSpvcVccStatsInCellCountHiB Integer32
  frAtmSpvcVccStatsInCellCountLoB Integer32
  frAtmSpvcVccStatsOutCellCountHiB Integer32
  frAtmSpvcVccStatsOutCellCountLoB Integer32
  frAtmSpvcVccStatsTimer Integer32
  frAtmSpvcVccStatsFramesDroppedA Integer32
  frAtmSpvcVccStatsOdometerCellsEncodedHiA Integer32
  frAtmSpvcVccStatsOdometerCellsEncodedLoA Integer32
  frAtmSpvcVccStatsOdometerCellsDecodedHiA Integer32
  frAtmSpvcVccStatsOdometerCellsDecodedLoA Integer32
  frAtmSpvcVccStatsInOdometerCellCountHiB Integer32
  frAtmSpvcVccStatsInOdometerCellCountLoB Integer32
  frAtmSpvcVccStatsOutOdometerCellCountHiB Integer32
  frAtmSpvcVccStatsOutOdometerCellCountLoB Integer32
  frAtmSpvcVccStatsOdometerTimer Integer32
  frAtmSpvcVccStatsOdometerReset INTEGER
  frAtmSpvcVccStatsAal5ErrFramesA Integer32
  frAtmSpvcVccStatsFramesTaggedA Integer32
  frAtmSpvcVccStatsCellsDroppedB Integer32
  frAtmSpvcVccStatsCellsTaggedB Integer32
  frAtmSpvcVccVUNIB INTEGER
  frAtmSpvcVccTrafficShapingA2B INTEGER
  frAtmSpvcVccPriority INTEGER

AtmAtmSpvcVccEntry  
SEQUENCE    
  atmAtmSpvcVccVpiA INTEGER
  atmAtmSpvcVccVciA INTEGER
  atmAtmSpvcVccRemoteAtmPortAddr OCTET STRING
  atmAtmSpvcVccIfB IntfIndex
  atmAtmSpvcVccVpiB INTEGER
  atmAtmSpvcVccVciB INTEGER
  atmAtmSpvcVccServiceTypeA2B INTEGER
  atmAtmSpvcVccSarTypeA2B INTEGER
  atmAtmSpvcVccPeakCellRateA2B Integer32
  atmAtmSpvcVccSusCellRateA2B Integer32
  atmAtmSpvcVccMaxBurstSizeA2B Integer32
  atmAtmSpvcVccFrwdErrCorrectionA2B INTEGER
  atmAtmSpvcVccServiceTypeB2A INTEGER
  atmAtmSpvcVccSarTypeB2A INTEGER
  atmAtmSpvcVccPeakCellRateB2A Integer32
  atmAtmSpvcVccSusCellRateB2A Integer32
  atmAtmSpvcVccMaxBurstSizeB2A Integer32
  atmAtmSpvcVccFrwdErrCorrectionB2A INTEGER
  atmAtmSpvcVccFlow INTEGER
  atmAtmSpvcVccType INTEGER
  atmAtmSpvcVccConnType INTEGER
  atmAtmSpvcVccLeafReference INTEGER
  atmAtmSpvcVccOperStatus INTEGER
  atmAtmSpvcVccRowStatus RowStatus
  atmAtmSpvcVccRemoteSelectType INTEGER
  atmAtmSpvcVccRemoteVpi INTEGER
  atmAtmSpvcVccRemoteVci INTEGER
  atmAtmSpvcVccRetryInterval INTEGER
  atmAtmSpvcVccRetryLimit INTEGER
  atmAtmSpvcVccRestart INTEGER
  atmAtmSpvcVccRetryFailure Integer32
  atmAtmSpvcVccReleaseCause INTEGER
  atmAtmSpvcVccReleaseDiag OCTET STRING
  atmAtmSpvcVccRelease INTEGER
  atmAtmSpvcVccStatsInCellCountHiA Integer32
  atmAtmSpvcVccStatsInCellCountLoA Integer32
  atmAtmSpvcVccStatsOutCellCountHiA Integer32
  atmAtmSpvcVccStatsOutCellCountLoA Integer32
  atmAtmSpvcVccStatsInCellCountHiB Integer32
  atmAtmSpvcVccStatsInCellCountLoB Integer32
  atmAtmSpvcVccStatsOutCellCountHiB Integer32
  atmAtmSpvcVccStatsOutCellCountLoB Integer32
  atmAtmSpvcVccStatsTimer Integer32
  atmAtmSpvcVccStatsFrwdErrCrrctnRateA2B INTEGER
  atmAtmSpvcVccStatsFrwdErrCrrctnRateB2A INTEGER
  atmAtmSpvcVccStatsInOdometerCellCountHiA Integer32
  atmAtmSpvcVccStatsInOdometerCellCountLoA Integer32
  atmAtmSpvcVccStatsOutOdometerCellCountHiA Integer32
  atmAtmSpvcVccStatsOutOdometerCellCountLoA Integer32
  atmAtmSpvcVccStatsInOdometerCellCountHiB Integer32
  atmAtmSpvcVccStatsInOdometerCellCountLoB Integer32
  atmAtmSpvcVccStatsOutOdometerCellCountHiB Integer32
  atmAtmSpvcVccStatsOutOdometerCellCountLoB Integer32
  atmAtmSpvcVccStatsOdometerTimer Integer32
  atmAtmSpvcVccStatsOdometerReset INTEGER
  atmAtmSpvcVccViA INTEGER
  atmAtmSpvcVccViB INTEGER
  atmAtmSpvcVccStatsCellsDroppedA Integer32
  atmAtmSpvcVccStatsCellsTaggedA Integer32
  atmAtmSpvcVccStatsCellsDroppedB Integer32
  atmAtmSpvcVccStatsCellsTaggedB Integer32
  atmAtmSpvcVccVUNIA INTEGER
  atmAtmSpvcVccVUNIB INTEGER
  atmAtmSpvcVccTrafficShapingA2B INTEGER
  atmAtmSpvcVccTrafficShapingB2A INTEGER
  atmAtmSpvcVccPriority INTEGER

CirAtmSpvcVccEntry  
SEQUENCE    
  cirAtmSpvcVccRemoteCePortAddr OCTET STRING
  cirAtmSpvcVccIfB IntfIndex
  cirAtmSpvcVccVpiB INTEGER
  cirAtmSpvcVccVciB INTEGER
  cirAtmSpvcVccVoiceCompressionA2B INTEGER
  cirAtmSpvcVccSilenceDetectionA2B INTEGER
  cirAtmSpvcVccEchoCancellationA2B INTEGER
  cirAtmSpvcVccCngToneDetectionA2B INTEGER
  cirAtmSpvcVccCodingTranslationA2B INTEGER
  cirAtmSpvcVccVoiceCompressionB2A INTEGER
  cirAtmSpvcVccSilenceDetectionB2A INTEGER
  cirAtmSpvcVccEchoCancellationB2A INTEGER
  cirAtmSpvcVccCngToneDetectionB2A INTEGER
  cirAtmSpvcVccCodingTranslationB2A INTEGER
  cirAtmSpvcVccFlow INTEGER
  cirAtmSpvcVccServiceType INTEGER
  cirAtmSpvcVccConnType INTEGER
  cirAtmSpvcVccOperStatus INTEGER
  cirAtmSpvcVccRowStatus RowStatus
  cirAtmSpvcVccViB INTEGER
  cirAtmSpvcVccRetryInterval INTEGER
  cirAtmSpvcVccRetryLimit INTEGER
  cirAtmSpvcVccRestart INTEGER
  cirAtmSpvcVccRetryFailure Integer32
  cirAtmSpvcVccReleaseCause INTEGER
  cirAtmSpvcVccReleaseDiag OCTET STRING
  cirAtmSpvcVccRelease INTEGER
  cirAtmSpvcVccStatsCellsEncodedHiA Integer32
  cirAtmSpvcVccStatsCellsEncodedLoA Integer32
  cirAtmSpvcVccStatsCellsDecodedHiA Integer32
  cirAtmSpvcVccStatsCellsDecodedLoA Integer32
  cirAtmSpvcVccStatsInCellCountHiB Integer32
  cirAtmSpvcVccStatsInCellCountLoB Integer32
  cirAtmSpvcVccStatsOutCellCountHiB Integer32
  cirAtmSpvcVccStatsOutCellCountLoB Integer32
  cirAtmSpvcVccStatsTimer Integer32
  cirAtmSpvcVccStatsOdometerCellsEncodedHiA Integer32
  cirAtmSpvcVccStatsOdometerCellsEncodedLoA Integer32
  cirAtmSpvcVccStatsOdometerCellsDecodedHiA Integer32
  cirAtmSpvcVccStatsOdometerCellsDecodedLoA Integer32
  cirAtmSpvcVccStatsInOdometerCellCountHiB Integer32
  cirAtmSpvcVccStatsInOdometerCellCountLoB Integer32
  cirAtmSpvcVccStatsOutOdometerCellCountHiB Integer32
  cirAtmSpvcVccStatsOutOdometerCellCountLoB Integer32
  cirAtmSpvcVccStatsOdometerTimer Integer32
  cirAtmSpvcVccStatsOdometerReset INTEGER
  cirAtmSpvcVccStatsCellsDroppedB Integer32
  cirAtmSpvcVccStatsCellsTaggedB Integer32
  cirAtmSpvcVccVUNIB INTEGER
  cirAtmSpvcVccSarTypeB Integer32
  cirAtmSpvcVccPriority INTEGER

VbrAtmSpvcEntry  
SEQUENCE    
  vbrAtmSpvcRemoteVbrPortAddr OCTET STRING
  vbrAtmSpvcIfB IntfIndex
  vbrAtmSpvcVpiB INTEGER
  vbrAtmSpvcVciB INTEGER
  vbrAtmSpvcServiceType INTEGER
  vbrAtmSpvcPeakCellRateA2B Integer32
  vbrAtmSpvcSusCellRateA2B Integer32
  vbrAtmSpvcMaxBurstSizeA2B Integer32
  vbrAtmSpvcPeakCellRateB2A Integer32
  vbrAtmSpvcSusCellRateB2A Integer32
  vbrAtmSpvcMaxBurstSizeB2A Integer32
  vbrAtmSpvcFlow INTEGER
  vbrAtmSpvcConnType INTEGER
  vbrAtmSpvcOperStatus INTEGER
  vbrAtmSpvcRowStatus RowStatus
  vbrAtmSpvcViB INTEGER
  vbrAtmSpvcRetryInterval INTEGER
  vbrAtmSpvcRetryLimit INTEGER
  vbrAtmSpvcRestart INTEGER
  vbrAtmSpvcRetryFailure Integer32
  vbrAtmSpvcReleaseCause INTEGER
  vbrAtmSpvcReleaseDiag OCTET STRING
  vbrAtmSpvcRelease INTEGER
  vbrAtmSpvcStatsCellsEncodedHiA Integer32
  vbrAtmSpvcStatsCellsEncodedLoA Integer32
  vbrAtmSpvcStatsCellsDecodedHiA Integer32
  vbrAtmSpvcStatsCellsDecodedLoA Integer32
  vbrAtmSpvcStatsInCellCountHiB Integer32
  vbrAtmSpvcStatsInCellCountLoB Integer32
  vbrAtmSpvcStatsOutCellCountHiB Integer32
  vbrAtmSpvcStatsOutCellCountLoB Integer32
  vbrAtmSpvcStatsTimer Integer32
  vbrAtmSpvcStatsOdometerCellsEncodedHiA Integer32
  vbrAtmSpvcStatsOdometerCellsEncodedLoA Integer32
  vbrAtmSpvcStatsOdometerCellsDecodedHiA Integer32
  vbrAtmSpvcStatsOdometerCellsDecodedLoA Integer32
  vbrAtmSpvcStatsInOdometerCellCountHiB Integer32
  vbrAtmSpvcStatsInOdometerCellCountLoB Integer32
  vbrAtmSpvcStatsOutOdometerCellCountHiB Integer32
  vbrAtmSpvcStatsOutOdometerCellCountLoB Integer32
  vbrAtmSpvcStatsOdometerTimer Integer32
  vbrAtmSpvcStatsOdometerReset INTEGER
  vbrAtmSpvcStatsCellsDroppedB Integer32
  vbrAtmSpvcStatsCellsTaggedB Integer32
  vbrAtmSpvcVUNIB INTEGER
  vbrAtmSpvcTrafficShapingA2B INTEGER
  vbrAtmSpvcPriority INTEGER

Aal2TrunkConfigEntry  
SEQUENCE    
  aal2TrunkConfigIf IntfIndex
  aal2TrunkConfigVpi INTEGER
  aal2TrunkConfigVci INTEGER
  aal2TrunkConfigServiceType INTEGER
  aal2TrunkConfigPeakCellRateIgr Integer32
  aal2TrunkConfigSusCellRateIgr Integer32
  aal2TrunkConfigMaxBurstSizeIgr Integer32
  aal2TrunkConfigPeakCellRateEgr Integer32
  aal2TrunkConfigSusCellRateEgr Integer32
  aal2TrunkConfigMaxBurstSizeEgr Integer32
  aal2TrunkConfigFlow INTEGER
  aal2TrunkConfigRowStatus RowStatus
  aal2TrunkConfigConnectionStatus INTEGER
  aal2TrunkConfigViB INTEGER
  aal2TrunkConfigCnfrmTypeB2A INTEGER
  aal2TrunkConfigVUNIB INTEGER
  aal2TrunkAvailBwIgr INTEGER
  aal2TrunkAvailBwEgr INTEGER
  aal2TrunkGR303 INTEGER
  aal2TrunkConfigOamStatus INTEGER
  aal2TrunkConnFailureCauseB AtmConnFailureCause
  aal2TrunkCuTimer INTEGER

Gr303Aal2PvcVccEntry  
SEQUENCE    
  gr303Aal2PvcVccGr303IgId INTEGER
  gr303Aal2PvcVccGr303CallRef INTEGER
  gr303Aal2PvcVccIfB IntfIndex
  gr303Aal2PvcVccVpiB INTEGER
  gr303Aal2PvcVccVciB INTEGER
  gr303Aal2PvcVccAal2Cid INTEGER
  gr303Aal2PvcVccRowStatus RowStatus
  gr303Aal2PvcVccVoiceEncodingProfile INTEGER
  gr303Aal2PvcVccVoiceCompression INTEGER
  gr303Aal2PvcVccSilenceDetection INTEGER
  gr303Aal2PvcVccEchoCancellation INTEGER
  gr303Aal2PvcVccCngToneDetection INTEGER
  gr303Aal2PvcVccCodingTranslation INTEGER
  gr303Aal2PvcVccConnectionStatus INTEGER
  gr303Aal2PvcVccAltLineType INTEGER

AtmAtmSpvcVpcEntry  
SEQUENCE    
  atmAtmSpvcVpcVpiA INTEGER
  atmAtmSpvcVpcRemoteAtmPortAddr OCTET STRING
  atmAtmSpvcVpcIfB IntfIndex
  atmAtmSpvcVpcVpiB INTEGER
  atmAtmSpvcVpcServiceTypeA2B INTEGER
  atmAtmSpvcVpcSarTypeA2B INTEGER
  atmAtmSpvcVpcPeakCellRateA2B Integer32
  atmAtmSpvcVpcSusCellRateA2B Integer32
  atmAtmSpvcVpcMaxBurstSizeA2B Integer32
  atmAtmSpvcVpcFrwdErrCorrectionA2B INTEGER
  atmAtmSpvcVpcServiceTypeB2A INTEGER
  atmAtmSpvcVpcSarTypeB2A INTEGER
  atmAtmSpvcVpcPeakCellRateB2A Integer32
  atmAtmSpvcVpcSusCellRateB2A Integer32
  atmAtmSpvcVpcMaxBurstSizeB2A Integer32
  atmAtmSpvcVpcFrwdErrCorrectionB2A INTEGER
  atmAtmSpvcVpcFlow INTEGER
  atmAtmSpvcVpcType INTEGER
  atmAtmSpvcVpcConnType INTEGER
  atmAtmSpvcVpcLeafReference INTEGER
  atmAtmSpvcVpcOperStatus INTEGER
  atmAtmSpvcVpcRowStatus RowStatus
  atmAtmSpvcVpcRemoteSelectType INTEGER
  atmAtmSpvcVpcRemoteVpi INTEGER
  atmAtmSpvcVpcRetryInterval INTEGER
  atmAtmSpvcVpcRetryLimit INTEGER
  atmAtmSpvcVpcRestart INTEGER
  atmAtmSpvcVpcRetryFailure Integer32
  atmAtmSpvcVpcReleaseCause INTEGER
  atmAtmSpvcVpcReleaseDiag OCTET STRING
  atmAtmSpvcVpcRelease INTEGER
  atmAtmSpvcVpcStatsInCellCountHiA Integer32
  atmAtmSpvcVpcStatsInCellCountLoA Integer32
  atmAtmSpvcVpcStatsOutCellCountHiA Integer32
  atmAtmSpvcVpcStatsOutCellCountLoA Integer32
  atmAtmSpvcVpcStatsInCellCountHiB Integer32
  atmAtmSpvcVpcStatsInCellCountLoB Integer32
  atmAtmSpvcVpcStatsOutCellCountHiB Integer32
  atmAtmSpvcVpcStatsOutCellCountLoB Integer32
  atmAtmSpvcVpcStatsTimer Integer32
  atmAtmSpvcVpcStatsFrwdErrCrrctnRateA2B INTEGER
  atmAtmSpvcVpcStatsFrwdErrCrrctnRateB2A INTEGER
  atmAtmSpvcVpcStatsInOdometerCellCountHiA Integer32
  atmAtmSpvcVpcStatsInOdometerCellCountLoA Integer32
  atmAtmSpvcVpcStatsOutOdometerCellCountHiA Integer32
  atmAtmSpvcVpcStatsOutOdometerCellCountLoA Integer32
  atmAtmSpvcVpcStatsInOdometerCellCountHiB Integer32
  atmAtmSpvcVpcStatsInOdometerCellCountLoB Integer32
  atmAtmSpvcVpcStatsOutOdometerCellCountHiB Integer32
  atmAtmSpvcVpcStatsOutOdometerCellCountLoB Integer32
  atmAtmSpvcVpcStatsOdometerTimer Integer32
  atmAtmSpvcVpcStatsOdometerReset INTEGER
  atmAtmSpvcVpcViA INTEGER
  atmAtmSpvcVpcViB INTEGER
  atmAtmSpvcVpcStatsCellsDroppedA Integer32
  atmAtmSpvcVpcStatsCellsTaggedA Integer32
  atmAtmSpvcVpcStatsCellsDroppedB Integer32
  atmAtmSpvcVpcStatsCellsTaggedB Integer32
  atmAtmSpvcVpcVUNIA INTEGER
  atmAtmSpvcVpcVUNIB INTEGER
  atmAtmSpvcVpcTrafficShapingA2B INTEGER
  atmAtmSpvcVpcTrafficShapingB2A INTEGER
  atmAtmSpvcVpcPriority INTEGER

IntfAtmConnDisplayEntry  
SEQUENCE    
  intfAtmPvcConnDisplaySlot Integer32
  intfAtmPvcConnDisplayPort Integer32
  intfAtmPvcConnDisplayChannel Integer32
  intfAtmPvcConnDisplayVpi INTEGER
  intfAtmPvcConnDisplayVci INTEGER
  intfAtmPvcConnDisplayFlowType INTEGER

Ds3PortStatsEntry  
SEQUENCE    
  ds3PortStatsId Integer32
  ds3PortStatsTimer Integer32
  ds3PortStatsCurrentSEFSs Integer32
  ds3PortStatsCurrentLCVs Integer32
  ds3PortStatsCurrentLESs Integer32

Ds1PortStatsEntry  
SEQUENCE    
  ds1PortStatsId Integer32
  ds1PortStatsTimer Integer32
  ds1PortStatsCurrentESs Integer32
  ds1PortStatsCurrentSESs Integer32
  ds1PortStatsCurrentLCVs Integer32

Oc3PortStatsEntry  
SEQUENCE    
  oc3PortStatsId Integer32
  oc3PortStatsSectionBip8Errs Integer32
  oc3PortStatsLineBip8Errs Integer32
  oc3PortStatsPathBip8Errs Integer32
  oc3PortStatsLineFebeCount Integer32
  oc3PortStatsPathFebeCount Integer32
  oc3PortStatsTimer Integer32

MsPortStatsEntry  
SEQUENCE    
  msPortStatsId Integer32
  msPortStatsFrameErrors Integer32
  msPortStatsOutOfFrameSeconds Integer32
  msPortStatsTimer Integer32

E3PortStatsEntry  
SEQUENCE    
  e3PortStatsId Integer32
  e3PortStatsTimer Integer32
  e3PortStatsCurrentSEFSs Integer32
  e3PortStatsCurrentLCVs Integer32
  e3PortStatsCurrentLESs Integer32

E1PortStatsEntry  
SEQUENCE    
  e1PortStatsId Integer32
  e1PortStatsTimer Integer32
  e1PortStatsCurrentESs Integer32
  e1PortStatsCurrentSESs Integer32
  e1PortStatsCurrentLCVs Integer32

EthernetPortStatsEntry  
SEQUENCE    
  ethernetPortStatsId Integer32
  ethernetPortStatsTimer Integer32
  ethernetPortStatsAlignmentErrors Integer32
  ethernetPortStatsFCSErrors Integer32
  ethernetPortStatsSingleCollisionFrames Integer32
  ethernetPortStatsMultipleCollisionFrames Integer32
  ethernetPortStatsSQETestErrors Integer32
  ethernetPortStatsDeferredTransmissions Integer32
  ethernetPortStatsLateCollisions Integer32
  ethernetPortStatsExcessiveCollisions Integer32
  ethernetPortStatsInternalMacTransmitErrors Integer32
  ethernetPortStatsCarrierSenseErrors Integer32
  ethernetPortStatsFrameTooLongs Integer32
  ethernetPortStatsInternalMacReceiveErrors Integer32

AtmIfStatsEntry  
SEQUENCE    
  atmIfStatsId IntfIndex
  atmIfStatsValidCellsInHi Integer32
  atmIfStatsValidCellsInLo Integer32
  atmIfStatsErroredCellsIn Integer32
  atmIfStatsMismatchedCellsIn Integer32
  atmIfStatsNullCellsOutHi Integer32
  atmIfStatsNullCellsOutLo Integer32
  atmIfStatsValidCellsOutHi Integer32
  atmIfStatsValidCellsOutLo Integer32
  atmIfStatsTimer Integer32

FrUniStatsEntry  
SEQUENCE    
  frUniStatsId IntfIndex
  frUniStatsTimer INTEGER
  frUniStatsCellsMismatched Integer32
  frUniStatsErroredFrames Integer32
  frUniStatsCellsEncodedHi Integer32
  frUniStatsCellsEncodedLo Integer32
  frUniStatsFramesEncodedHi Integer32
  frUniStatsFramesEncodedLo Integer32
  frUniStatsCellsDecodedHi Integer32
  frUniStatsCellsDecodedLo Integer32
  frUniStatsFramesDecodedHi Integer32
  frUniStatsFramesDecodedLo Integer32
  frUniStatsAAL5Errors Integer32

CirEmIfStatsEntry  
SEQUENCE    
  cirEmIfStatsId IntfIndex
  cirEmIfStatsCellsEncodedHi Integer32
  cirEmIfStatsCellsEncodedLo Integer32
  cirEmIfStatsCellsDecodedHi Integer32
  cirEmIfStatsCellsDecodedLo Integer32
  cirEmIfStatsTimer Integer32

VbrIfStatsEntry  
SEQUENCE    
  vbrIfStatsId IntfIndex
  vbrIfStatsCellsEncodedHi Integer32
  vbrIfStatsCellsEncodedLo Integer32
  vbrIfStatsCellsDecodedHi Integer32
  vbrIfStatsCellsDecodedLo Integer32
  vbrIfStatsTimer Integer32

FrLmiStatsEntry  
SEQUENCE    
  frLmiStatsId IntfIndex
  frLmiStatsEnqRx Integer32
  frLmiStatsEnqTx Integer32
  frLmiStatsStatusRx Integer32
  frLmiStatsStatusTx Integer32
  frLmiStatsAsyncRx Integer32
  frLmiStatsAsyncTx Integer32
  frLmiStatsPktDisc Integer32
  frLmiStatsT391Exp INTEGER
  frLmiStatsT392Exp INTEGER
  frLmiStatsLinkReset INTEGER
  frLmiStatsTimer INTEGER

BridgeStatsEntry  
SEQUENCE    
  bridgeStatsId Integer32
  bridgeStatsTimer Integer32
  bridgeStatsBasePortDelayExceededDiscardsHi Integer32
  bridgeStatsBasePortDelayExceededDiscardsLo Integer32
  bridgeStatsBasePortMtuExceededDiscardsHi Integer32
  bridgeStatsBasePortMtuExceededDiscardsLo Integer32
  bridgeStatsTpPortInFramesHi Integer32
  bridgeStatsTpPortInFramesLo Integer32
  bridgeStatsTpPortOutFramesHi Integer32
  bridgeStatsTpPortOutFramesLo Integer32
  bridgeStatsTpPortInDiscardsHi Integer32
  bridgeStatsTpPortInDiscardsLo Integer32

DbCirEmIfStatsEntry  
SEQUENCE    
  dbCirEmIfStatsId IntfIndex
  dbCirEmIfStatsCellsEncodedHi Integer32
  dbCirEmIfStatsCellsEncodedLo Integer32
  dbCirEmIfStatsCellsDecodedHi Integer32
  dbCirEmIfStatsCellsDecodedLo Integer32
  dbCirEmIfStatsTimer Integer32

AtmImaStatsEntry  
SEQUENCE    
  atmImaStatsId IntfIndex
  atmImaStatsTimer Integer32
  atmImaStatsImaViolations Integer32
  atmImaStatsOifAnomalies Integer32
  atmImaStatsNeTxNumFailures Integer32
  atmImaStatsNeRxNumFailures Integer32
  atmImaStatsFeTxNumFailures Integer32
  atmImaStatsFeRxNumFailures Integer32
  atmImaStatsTxStuffs Integer32
  atmImaStatsRxStuffs Integer32

IlmiStatsEntry  
SEQUENCE    
  ilmiStatsId IntfIndex
  ilmiStatsTimer Integer32
  ilmiStatsLinkResets Integer32
  ilmiStatsAttachPtChanged Integer32
  ilmiStatsAttachPtVerified Integer32
  ilmiStatsSecureLnkProcInit Integer32
  ilmiStatsColdStartRx Integer32
  ilmiStatsColdStartTx Integer32
  ilmiStatsPduRx Integer32
  ilmiStatsPduTx Integer32
  ilmiStatsReqTimeouts Integer32
  ilmiStatsPacketDisc Integer32

VuniIlmiStatsEntry  
SEQUENCE    
  vuniIlmiStatsId IntfIndex
  vuniIlmiVUNIId INTEGER
  vuniIlmiStatsTimer Integer32
  vuniIlmiStatsLinkResets Integer32
  vuniIlmiStatsAttachPtChanged Integer32
  vuniIlmiStatsAttachPtVerified Integer32
  vuniIlmiStatsSecureLnkProcInit Integer32
  vuniIlmiStatsColdStartRx Integer32
  vuniIlmiStatsColdStartTx Integer32
  vuniIlmiStatsPduRx Integer32
  vuniIlmiStatsPduTx Integer32
  vuniIlmiStatsReqTimeouts Integer32
  vuniIlmiStatsPacketDisc Integer32
  vuniResetIlmiStatistics INTEGER

AtmPvcVccStatsEntry  
SEQUENCE    
  atmPvcVccStatsIfA IntfIndex
  atmPvcVccStatsVpiA INTEGER
  atmPvcVccStatsVciA INTEGER
  atmPvcVccStatsIfB IntfIndex
  atmPvcVccStatsVpiB INTEGER
  atmPvcVccStatsVciB INTEGER
  atmPvcVccStatsInCellCountHiA Integer32
  atmPvcVccStatsInCellCountLoA Integer32
  atmPvcVccStatsOutCellCountHiA Integer32
  atmPvcVccStatsOutCellCountLoA Integer32
  atmPvcVccStatsInCellCountHiB Integer32
  atmPvcVccStatsInCellCountLoB Integer32
  atmPvcVccStatsOutCellCountHiB Integer32
  atmPvcVccStatsOutCellCountLoB Integer32
  atmPvcVccStatsTimer Integer32
  atmPvcVccStatsFrwdErrCrrctnRateA2B INTEGER
  atmPvcVccStatsFrwdErrCrrctnRateB2A INTEGER
  atmPvcVccStatsInOdometerCellCountHiA Integer32
  atmPvcVccStatsInOdometerCellCountLoA Integer32
  atmPvcVccStatsOutOdometerCellCountHiA Integer32
  atmPvcVccStatsOutOdometerCellCountLoA Integer32
  atmPvcVccStatsInOdometerCellCountHiB Integer32
  atmPvcVccStatsInOdometerCellCountLoB Integer32
  atmPvcVccStatsOutOdometerCellCountHiB Integer32
  atmPvcVccStatsOutOdometerCellCountLoB Integer32
  atmPvcVccStatsOdometerTimer Integer32
  atmPvcVccStatsOdometerReset INTEGER
  atmPvcVccStatsOamAisTxA Integer32
  atmPvcVccStatsOamAisRxA Integer32
  atmPvcVccStatsOamRdiTxA Integer32
  atmPvcVccStatsOamRdiRxA Integer32
  atmPvcVccStatsOamAisTxB Integer32
  atmPvcVccStatsOamAisRxB Integer32
  atmPvcVccStatsOamRdiTxB Integer32
  atmPvcVccStatsOamRdiRxB Integer32
  atmPvcVccStatsCellsDroppedA Integer32
  atmPvcVccStatsCellsTaggedA Integer32
  atmPvcVccStatsCellsDroppedB Integer32
  atmPvcVccStatsCellsTaggedB Integer32

AtmPvcVpcStatsEntry  
SEQUENCE    
  atmPvcVpcStatsIfA IntfIndex
  atmPvcVpcStatsVpiA INTEGER
  atmPvcVpcStatsIfB IntfIndex
  atmPvcVpcStatsVpiB INTEGER
  atmPvcVpcStatsInCellCountHiA Integer32
  atmPvcVpcStatsInCellCountLoA Integer32
  atmPvcVpcStatsOutCellCountHiA Integer32
  atmPvcVpcStatsOutCellCountLoA Integer32
  atmPvcVpcStatsInCellCountHiB Integer32
  atmPvcVpcStatsInCellCountLoB Integer32
  atmPvcVpcStatsOutCellCountHiB Integer32
  atmPvcVpcStatsOutCellCountLoB Integer32
  atmPvcVpcStatsTimer Integer32
  atmPvcVpcStatsInOdometerCellCountHiA Integer32
  atmPvcVpcStatsInOdometerCellCountLoA Integer32
  atmPvcVpcStatsOutOdometerCellCountHiA Integer32
  atmPvcVpcStatsOutOdometerCellCountLoA Integer32
  atmPvcVpcStatsInOdometerCellCountHiB Integer32
  atmPvcVpcStatsInOdometerCellCountLoB Integer32
  atmPvcVpcStatsOutOdometerCellCountHiB Integer32
  atmPvcVpcStatsOutOdometerCellCountLoB Integer32
  atmPvcVpcStatsOdometerTimer Integer32
  atmPvcVpcStatsOdometerReset INTEGER
  atmPvcVpcStatsOamAisTxA Integer32
  atmPvcVpcStatsOamAisRxA Integer32
  atmPvcVpcStatsOamRdiTxA Integer32
  atmPvcVpcStatsOamRdiRxA Integer32
  atmPvcVpcStatsOamAisTxB Integer32
  atmPvcVpcStatsOamAisRxB Integer32
  atmPvcVpcStatsOamRdiTxB Integer32
  atmPvcVpcStatsOamRdiRxB Integer32
  atmPvcVpcStatsCellsDroppedA Integer32
  atmPvcVpcStatsCellsTaggedA Integer32
  atmPvcVpcStatsCellsDroppedB Integer32
  atmPvcVpcStatsCellsTaggedB Integer32

AtmSvcVccStatsEntry  
SEQUENCE    
  atmSvcVccStatsIfA IntfIndex
  atmSvcVccStatsVpiA INTEGER
  atmSvcVccStatsVciA INTEGER
  atmSvcVccStatsIfB IntfIndex
  atmSvcVccStatsVpiB INTEGER
  atmSvcVccStatsVciB INTEGER
  atmSvcVccStatsInCellCountHiA Integer32
  atmSvcVccStatsInCellCountLoA Integer32
  atmSvcVccStatsOutCellCountHiA Integer32
  atmSvcVccStatsOutCellCountLoA Integer32
  atmSvcVccStatsInCellCountHiB Integer32
  atmSvcVccStatsInCellCountLoB Integer32
  atmSvcVccStatsOutCellCountHiB Integer32
  atmSvcVccStatsOutCellCountLoB Integer32
  atmSvcVccStatsTimer Integer32
  atmSvcVccStatsInOdometerCellCountHiA Integer32
  atmSvcVccStatsInOdometerCellCountLoA Integer32
  atmSvcVccStatsOutOdometerCellCountHiA Integer32
  atmSvcVccStatsOutOdometerCellCountLoA Integer32
  atmSvcVccStatsInOdometerCellCountHiB Integer32
  atmSvcVccStatsInOdometerCellCountLoB Integer32
  atmSvcVccStatsOutOdometerCellCountHiB Integer32
  atmSvcVccStatsOutOdometerCellCountLoB Integer32
  atmSvcVccStatsOdometerTimer Integer32
  atmSvcVccStatsOdometerReset INTEGER
  atmSvcVccStatsCellsDroppedA Integer32
  atmSvcVccStatsCellsTaggedA Integer32
  atmSvcVccStatsCellsDroppedB Integer32
  atmSvcVccStatsCellsTaggedB Integer32

IpAtmAppPvcVccStatsEntry  
SEQUENCE    
  ipAtmAppPvcVccStatsDestAddrA IpAddress
  ipAtmAppPvcVccStatsSubnetMaskA IpAddress
  ipAtmAppPvcVccStatsIfB IntfIndex
  ipAtmAppPvcVccStatsVpiB INTEGER
  ipAtmAppPvcVccStatsVciB INTEGER
  ipAtmAppPvcVccStatsInCellCountHiA Integer32
  ipAtmAppPvcVccStatsInCellCountLoA Integer32
  ipAtmAppPvcVccStatsOutCellCountHiA Integer32
  ipAtmAppPvcVccStatsOutCellCountLoA Integer32
  ipAtmAppPvcVccStatsFramesInB Integer32
  ipAtmAppPvcVccStatsFramesOutB Integer32
  ipAtmAppPvcVccStatsInCellCountHiB Integer32
  ipAtmAppPvcVccStatsInCellCountLoB Integer32
  ipAtmAppPvcVccStatsOutCellCountHiB Integer32
  ipAtmAppPvcVccStatsOutCellCountLoB Integer32
  ipAtmAppPvcVccStatsTimer Integer32
  ipAtmAppPvcVccStatsInOdometerCellCountHiA Integer32
  ipAtmAppPvcVccStatsInOdometerCellCountLoA Integer32
  ipAtmAppPvcVccStatsOutOdometerCellCountHiA Integer32
  ipAtmAppPvcVccStatsOutOdometerCellCountLoA Integer32
  ipAtmAppPvcVccStatsOdometerFramesInB Integer32
  ipAtmAppPvcVccStatsOdometerFramesOutB Integer32
  ipAtmAppPvcVccStatsInOdometerCellCountHiB Integer32
  ipAtmAppPvcVccStatsInOdometerCellCountLoB Integer32
  ipAtmAppPvcVccStatsOutOdometerCellCountHiB Integer32
  ipAtmAppPvcVccStatsOutOdometerCellCountLoB Integer32
  ipAtmAppPvcVccStatsOdometerTimer Integer32
  ipAtmAppPvcVccStatsOdometerReset INTEGER
  ipAtmAppPvcVccStatsCellsDroppedB Integer32
  ipAtmAppPvcVccStatsCellsTaggedB Integer32

IpAtmAppSvcVccStatsEntry  
SEQUENCE    
  ipAtmAppSvcVccStatsDestAddrA IpAddress
  ipAtmAppSvcVccStatsSubnetMaskA IpAddress
  ipAtmAppSvcVccStatsIfB IntfIndex
  ipAtmAppSvcVccStatsVpiB INTEGER
  ipAtmAppSvcVccStatsVciB INTEGER
  ipAtmAppSvcVccStatsInCellCountHiA Integer32
  ipAtmAppSvcVccStatsInCellCountLoA Integer32
  ipAtmAppSvcVccStatsOutCellCountHiA Integer32
  ipAtmAppSvcVccStatsOutCellCountLoA Integer32
  ipAtmAppSvcVccStatsFramesInB Integer32
  ipAtmAppSvcVccStatsFramesOutB Integer32
  ipAtmAppSvcVccStatsInCellCountHiB Integer32
  ipAtmAppSvcVccStatsInCellCountLoB Integer32
  ipAtmAppSvcVccStatsOutCellCountHiB Integer32
  ipAtmAppSvcVccStatsOutCellCountLoB Integer32
  ipAtmAppSvcVccStatsTimer Integer32
  ipAtmAppSvcVccStatsCellsDroppedB Integer32
  ipAtmAppSvcVccStatsCellsTaggedB Integer32

CirEmAtmPvcVccStatsEntry  
SEQUENCE    
  cirEmAtmPvcVccStatsIfA IntfIndex
  cirEmAtmPvcVccStatsIfB IntfIndex
  cirEmAtmPvcVccStatsVpiB INTEGER
  cirEmAtmPvcVccStatsVciB INTEGER
  cirEmAtmPvcVccStatsCellsEncodedHiA Integer32
  cirEmAtmPvcVccStatsCellsEncodedLoA Integer32
  cirEmAtmPvcVccStatsCellsDecodedHiA Integer32
  cirEmAtmPvcVccStatsCellsDecodedLoA Integer32
  cirEmAtmPvcVccStatsInCellCountHiB Integer32
  cirEmAtmPvcVccStatsInCellCountLoB Integer32
  cirEmAtmPvcVccStatsOutCellCountHiB Integer32
  cirEmAtmPvcVccStatsOutCellCountLoB Integer32
  cirEmAtmPvcVccStatsTimer Integer32
  cirEmAtmPvcVccStatsOdometerCellsEncodedHiA Integer32
  cirEmAtmPvcVccStatsOdometerCellsEncodedLoA Integer32
  cirEmAtmPvcVccStatsOdometerCellsDecodedHiA Integer32
  cirEmAtmPvcVccStatsOdometerCellsDecodedLoA Integer32
  cirEmAtmPvcVccStatsInOdometerCellCountHiB Integer32
  cirEmAtmPvcVccStatsInOdometerCellCountLoB Integer32
  cirEmAtmPvcVccStatsOutOdometerCellCountHiB Integer32
  cirEmAtmPvcVccStatsOutOdometerCellCountLoB Integer32
  cirEmAtmPvcVccStatsOdometerTimer Integer32
  cirEmAtmPvcVccStatsOdometerReset INTEGER
  cirEmAtmPvcVccStatsOamAisTx Integer32
  cirEmAtmPvcVccStatsOamAisRx Integer32
  cirEmAtmPvcVccStatsOamRdiTx Integer32
  cirEmAtmPvcVccStatsOamRdiRx Integer32
  cirEmAtmPvcVccStatsCellsDroppedB Integer32
  cirEmAtmPvcVccStatsCellsTaggedB Integer32

FrAtmPvcVccStatsEntry  
SEQUENCE    
  frAtmPvcVccStatsIfA IntfIndex
  frAtmPvcVccStatsDlciA INTEGER
  frAtmPvcVccStatsIfB IntfIndex
  frAtmPvcVccStatsVpiB INTEGER
  frAtmPvcVccStatsVciB INTEGER
  frAtmPvcVccStatsCellsEncodedHiA Integer32
  frAtmPvcVccStatsCellsEncodedLoA Integer32
  frAtmPvcVccStatsCellsDecodedHiA Integer32
  frAtmPvcVccStatsCellsDecodedLoA Integer32
  frAtmPvcVccStatsInCellCountHiB Integer32
  frAtmPvcVccStatsInCellCountLoB Integer32
  frAtmPvcVccStatsOutCellCountHiB Integer32
  frAtmPvcVccStatsOutCellCountLoB Integer32
  frAtmPvcVccStatsTimer Integer32
  frAtmPvcVccStatsFramesDroppedA Integer32
  frAtmPvcVccStatsOdometerCellsEncodedHiA Integer32
  frAtmPvcVccStatsOdometerCellsEncodedLoA Integer32
  frAtmPvcVccStatsOdometerCellsDecodedHiA Integer32
  frAtmPvcVccStatsOdometerCellsDecodedLoA Integer32
  frAtmPvcVccStatsInOdometerCellCountHiB Integer32
  frAtmPvcVccStatsInOdometerCellCountLoB Integer32
  frAtmPvcVccStatsOutOdometerCellCountHiB Integer32
  frAtmPvcVccStatsOutOdometerCellCountLoB Integer32
  frAtmPvcVccStatsOdometerTimer Integer32
  frAtmPvcVccStatsOdometerFramesDroppedA Integer32
  frAtmPvcVccStatsOdometerReset INTEGER
  frAtmPvcVccStatsOamAisTx Integer32
  frAtmPvcVccStatsOamAisRx Integer32
  frAtmPvcVccStatsOamRdiTx Integer32
  frAtmPvcVccStatsOamRdiRx Integer32
  frAtmPvcVccStatsAal5ErrFramesA Integer32
  frAtmPvcVccStatsFramesTaggedA Integer32
  frAtmPvcVccStatsCellsDroppedB Integer32
  frAtmPvcVccStatsCellsTaggedB Integer32

FrFrPvcStatsEntry  
SEQUENCE    
  frFrPvcStatsIfA IntfIndex
  frFrPvcStatsDlciA INTEGER
  frFrPvcStatsIfB IntfIndex
  frFrPvcStatsDlciB INTEGER
  frFrPvcStatsCellsEncodedHiA Integer32
  frFrPvcStatsCellsEncodedLoA Integer32
  frFrPvcStatsCellsDecodedHiA Integer32
  frFrPvcStatsCellsDecodedLoA Integer32
  frFrPvcStatsCellsEncodedHiB Integer32
  frFrPvcStatsCellsEncodedLoB Integer32
  frFrPvcStatsCellsDecodedHiB Integer32
  frFrPvcStatsCellsDecodedLoB Integer32
  frFrPvcStatsTimer Integer32
  frFrPvcStatsFramesDroppedA Integer32
  frFrPvcStatsFramesDroppedB Integer32
  frFrPvcStatsOdometerCellsEncodedHiA Integer32
  frFrPvcStatsOdometerCellsEncodedLoA Integer32
  frFrPvcStatsOdometerCellsDecodedHiA Integer32
  frFrPvcStatsOdometerCellsDecodedLoA Integer32
  frFrPvcStatsOdometerCellsEncodedHiB Integer32
  frFrPvcStatsOdometerCellsEncodedLoB Integer32
  frFrPvcStatsOdometerCellsDecodedHiB Integer32
  frFrPvcStatsOdometerCellsDecodedLoB Integer32
  frFrPvcStatsOdometerTimer Integer32
  frFrPvcStatsOdometerFramesDroppedA Integer32
  frFrPvcStatsOdometerFramesDroppedB Integer32
  frFrPvcStatsOdometerReset INTEGER
  frFrPvcStatsAal5ErrFramesA Integer32
  frFrPvcStatsAal5ErrFramesB Integer32
  frFrPvcStatsFramesTaggedA Integer32
  frFrPvcStatsFramesTaggedB Integer32

VbrAtmPvcVccStatsEntry  
SEQUENCE    
  vbrAtmPvcVccStatsIfA IntfIndex
  vbrAtmPvcVccStatsIfB IntfIndex
  vbrAtmPvcVccStatsVpiB INTEGER
  vbrAtmPvcVccStatsVciB INTEGER
  vbrAtmPvcVccStatsCellsEncodedHiA Integer32
  vbrAtmPvcVccStatsCellsEncodedLoA Integer32
  vbrAtmPvcVccStatsCellsDecodedHiA Integer32
  vbrAtmPvcVccStatsCellsDecodedLoA Integer32
  vbrAtmPvcVccStatsInCellCountHiB Integer32
  vbrAtmPvcVccStatsInCellCountLoB Integer32
  vbrAtmPvcVccStatsOutCellCountHiB Integer32
  vbrAtmPvcVccStatsOutCellCountLoB Integer32
  vbrAtmPvcVccStatsTimer Integer32
  vbrAtmPvcVccStatsOdometerCellsEncodedHiA Integer32
  vbrAtmPvcVccStatsOdometerCellsEncodedLoA Integer32
  vbrAtmPvcVccStatsOdometerCellsDecodedHiA Integer32
  vbrAtmPvcVccStatsOdometerCellsDecodedLoA Integer32
  vbrAtmPvcVccStatsInOdometerCellCountHiB Integer32
  vbrAtmPvcVccStatsInOdometerCellCountLoB Integer32
  vbrAtmPvcVccStatsOutOdometerCellCountHiB Integer32
  vbrAtmPvcVccStatsOutOdometerCellCountLoB Integer32
  vbrAtmPvcVccStatsOdometerTimer Integer32
  vbrAtmPvcVccStatsOdometerReset INTEGER
  vbrAtmPvcVccStatsOamAisTx Integer32
  vbrAtmPvcVccStatsOamAisRx Integer32
  vbrAtmPvcVccStatsOamRdiTx Integer32
  vbrAtmPvcVccStatsOamRdiRx Integer32
  vbrAtmPvcVccStatsCellsDroppedB Integer32
  vbrAtmPvcVccStatsCellsTaggedB Integer32

CirEmCirEmPvcStatsEntry  
SEQUENCE    
  cirEmCirEmPvcStatsIfA IntfIndex
  cirEmCirEmPvcStatsIfB IntfIndex
  cirEmCirEmPvcStatsCellsEncodedHiA Integer32
  cirEmCirEmPvcStatsCellsEncodedLoA Integer32
  cirEmCirEmPvcStatsCellsDecodedHiA Integer32
  cirEmCirEmPvcStatsCellsDecodedLoA Integer32
  cirEmCirEmPvcStatsCellsEncodedHiB Integer32
  cirEmCirEmPvcStatsCellsEncodedLoB Integer32
  cirEmCirEmPvcStatsCellsDecodedHiB Integer32
  cirEmCirEmPvcStatsCellsDecodedLoB Integer32
  cirEmCirEmPvcStatsTimer Integer32
  cirEmCirEmPvcStatsOdometerCellsEncodedHiA Integer32
  cirEmCirEmPvcStatsOdometerCellsEncodedLoA Integer32
  cirEmCirEmPvcStatsOdometerCellsDecodedHiA Integer32
  cirEmCirEmPvcStatsOdometerCellsDecodedLoA Integer32
  cirEmCirEmPvcStatsOdometerCellsEncodedHiB Integer32
  cirEmCirEmPvcStatsOdometerCellsEncodedLoB Integer32
  cirEmCirEmPvcStatsOdometerCellsDecodedHiB Integer32
  cirEmCirEmPvcStatsOdometerCellsDecodedLoB Integer32
  cirEmCirEmPvcStatsOdometerTimer Integer32
  cirEmCirEmPvcStatsOdometerReset INTEGER

VbrVbrPvcStatsEntry  
SEQUENCE    
  vbrVbrPvcStatsIfA IntfIndex
  vbrVbrPvcStatsIfB IntfIndex
  vbrVbrPvcStatsCellsEncodedHiA Integer32
  vbrVbrPvcStatsCellsEncodedLoA Integer32
  vbrVbrPvcStatsCellsDecodedHiA Integer32
  vbrVbrPvcStatsCellsDecodedLoA Integer32
  vbrVbrPvcStatsCellsEncodedHiB Integer32
  vbrVbrPvcStatsCellsEncodedLoB Integer32
  vbrVbrPvcStatsCellsDecodedHiB Integer32
  vbrVbrPvcStatsCellsDecodedLoB Integer32
  vbrVbrPvcStatsTimer Integer32
  vbrVbrPvcStatsOdometerCellsEncodedHiA Integer32
  vbrVbrPvcStatsOdometerCellsEncodedLoA Integer32
  vbrVbrPvcStatsOdometerCellsDecodedHiA Integer32
  vbrVbrPvcStatsOdometerCellsDecodedLoA Integer32
  vbrVbrPvcStatsOdometerCellsEncodedHiB Integer32
  vbrVbrPvcStatsOdometerCellsEncodedLoB Integer32
  vbrVbrPvcStatsOdometerCellsDecodedHiB Integer32
  vbrVbrPvcStatsOdometerCellsDecodedLoB Integer32
  vbrVbrPvcStatsOdometerTimer Integer32
  vbrVbrPvcStatsOdometerReset INTEGER

BridgeBridgePvcStatsEntry  
SEQUENCE    
  bridgeBridgePvcStatsIfA IntfIndex
  bridgeBridgePvcStatsIfB IntfIndex
  bridgeBridgePvcStatsCellsEncodedHiA Integer32
  bridgeBridgePvcStatsCellsEncodedLoA Integer32
  bridgeBridgePvcStatsCellsDecodedHiA Integer32
  bridgeBridgePvcStatsCellsDecodedLoA Integer32
  bridgeBridgePvcStatsCellsEncodedHiB Integer32
  bridgeBridgePvcStatsCellsEncodedLoB Integer32
  bridgeBridgePvcStatsCellsDecodedHiB Integer32
  bridgeBridgePvcStatsCellsDecodedLoB Integer32
  bridgeBridgePvcStatsTimer Integer32
  bridgeBridgePvcStatsOdometerCellsEncodedHiA Integer32
  bridgeBridgePvcStatsOdometerCellsEncodedLoA Integer32
  bridgeBridgePvcStatsOdometerCellsDecodedHiA Integer32
  bridgeBridgePvcStatsOdometerCellsDecodedLoA Integer32
  bridgeBridgePvcStatsOdometerCellsEncodedHiB Integer32
  bridgeBridgePvcStatsOdometerCellsEncodedLoB Integer32
  bridgeBridgePvcStatsOdometerCellsDecodedHiB Integer32
  bridgeBridgePvcStatsOdometerCellsDecodedLoB Integer32
  bridgeBridgePvcStatsOdometerTimer Integer32
  bridgeBridgePvcStatsOdometerReset INTEGER

BridgeAtmPvcVccStatsEntry  
SEQUENCE    
  bridgeAtmPvcVccStatsIfA IntfIndex
  bridgeAtmPvcVccStatsIfB IntfIndex
  bridgeAtmPvcVccStatsVpiB INTEGER
  bridgeAtmPvcVccStatsVciB INTEGER
  bridgeAtmPvcVccStatsCellsEncodedHiA Integer32
  bridgeAtmPvcVccStatsCellsEncodedLoA Integer32
  bridgeAtmPvcVccStatsCellsDecodedHiA Integer32
  bridgeAtmPvcVccStatsCellsDecodedLoA Integer32
  bridgeAtmPvcVccStatsInCellCountHiB Integer32
  bridgeAtmPvcVccStatsInCellCountLoB Integer32
  bridgeAtmPvcVccStatsOutCellCountHiB Integer32
  bridgeAtmPvcVccStatsOutCellCountLoB Integer32
  bridgeAtmPvcVccStatsTimer Integer32
  bridgeAtmPvcVccStatsOdometerCellsEncodedHiA Integer32
  bridgeAtmPvcVccStatsOdometerCellsEncodedLoA Integer32
  bridgeAtmPvcVccStatsOdometerCellsDecodedHiA Integer32
  bridgeAtmPvcVccStatsOdometerCellsDecodedLoA Integer32
  bridgeAtmPvcVccStatsInOdometerCellCountHiB Integer32
  bridgeAtmPvcVccStatsInOdometerCellCountLoB Integer32
  bridgeAtmPvcVccStatsOutOdometerCellCountHiB Integer32
  bridgeAtmPvcVccStatsOutOdometerCellCountLoB Integer32
  bridgeAtmPvcVccStatsOdometerTimer Integer32
  bridgeAtmPvcVccStatsOdometerReset INTEGER
  bridgeAtmPvcVccStatsOamAisTx Integer32
  bridgeAtmPvcVccStatsOamAisRx Integer32
  bridgeAtmPvcVccStatsOamRdiTx Integer32
  bridgeAtmPvcVccStatsOamRdiRx Integer32
  bridgeAtmPvcVccStatsCellsDroppedB Integer32
  bridgeAtmPvcVccStatsCellsTaggedB Integer32

CirEmAtmSpvcVccStatsEntry  
SEQUENCE    
  cirEmAtmSpvcVccStatsIfA IntfIndex
  cirEmAtmSpvcVccStatsIfB IntfIndex
  cirEmAtmSpvcVccStatsVpiB INTEGER
  cirEmAtmSpvcVccStatsVciB INTEGER
  cirEmAtmSpvcVccStatsCellsEncodedHiA Integer32
  cirEmAtmSpvcVccStatsCellsEncodedLoA Integer32
  cirEmAtmSpvcVccStatsCellsDecodedHiA Integer32
  cirEmAtmSpvcVccStatsCellsDecodedLoA Integer32
  cirEmAtmSpvcVccStatsInCellCountHiB Integer32
  cirEmAtmSpvcVccStatsInCellCountLoB Integer32
  cirEmAtmSpvcVccStatsOutCellCountHiB Integer32
  cirEmAtmSpvcVccStatsOutCellCountLoB Integer32
  cirEmAtmSpvcVccStatsTimer Integer32
  cirEmAtmSpvcVccStatsOdometerCellsEncodedHiA Integer32
  cirEmAtmSpvcVccStatsOdometerCellsEncodedLoA Integer32
  cirEmAtmSpvcVccStatsOdometerCellsDecodedHiA Integer32
  cirEmAtmSpvcVccStatsOdometerCellsDecodedLoA Integer32
  cirEmAtmSpvcVccStatsInOdometerCellCountHiB Integer32
  cirEmAtmSpvcVccStatsInOdometerCellCountLoB Integer32
  cirEmAtmSpvcVccStatsOutOdometerCellCountHiB Integer32
  cirEmAtmSpvcVccStatsOutOdometerCellCountLoB Integer32
  cirEmAtmSpvcVccStatsOdometerTimer Integer32
  cirEmAtmSpvcVccStatsOdometerReset INTEGER
  cirEmAtmSpvcVccStatsCellsDroppedB Integer32
  cirEmAtmSpvcVccStatsCellsTaggedB Integer32

VbrAtmSpvcVccStatsEntry  
SEQUENCE    
  vbrAtmSpvcVccStatsIfA IntfIndex
  vbrAtmSpvcVccStatsIfB IntfIndex
  vbrAtmSpvcVccStatsVpiB INTEGER
  vbrAtmSpvcVccStatsVciB INTEGER
  vbrAtmSpvcVccStatsCellsEncodedHiA Integer32
  vbrAtmSpvcVccStatsCellsEncodedLoA Integer32
  vbrAtmSpvcVccStatsCellsDecodedHiA Integer32
  vbrAtmSpvcVccStatsCellsDecodedLoA Integer32
  vbrAtmSpvcVccStatsInCellCountHiB Integer32
  vbrAtmSpvcVccStatsInCellCountLoB Integer32
  vbrAtmSpvcVccStatsOutCellCountHiB Integer32
  vbrAtmSpvcVccStatsOutCellCountLoB Integer32
  vbrAtmSpvcVccStatsTimer Integer32
  vbrAtmSpvcVccStatsOdometerCellsEncodedHiA Integer32
  vbrAtmSpvcVccStatsOdometerCellsEncodedLoA Integer32
  vbrAtmSpvcVccStatsOdometerCellsDecodedHiA Integer32
  vbrAtmSpvcVccStatsOdometerCellsDecodedLoA Integer32
  vbrAtmSpvcVccStatsInOdometerCellCountHiB Integer32
  vbrAtmSpvcVccStatsInOdometerCellCountLoB Integer32
  vbrAtmSpvcVccStatsOutOdometerCellCountHiB Integer32
  vbrAtmSpvcVccStatsOutOdometerCellCountLoB Integer32
  vbrAtmSpvcVccStatsOdometerTimer Integer32
  vbrAtmSpvcVccStatsOdometerReset INTEGER
  vbrAtmSpvcVccStatsCellsDroppedB Integer32
  vbrAtmSpvcVccStatsCellsTaggedB Integer32

AtmSpvcVccStatsEntry  
SEQUENCE    
  atmSpvcVccStatsIfA IntfIndex
  atmSpvcVccStatsVpiA INTEGER
  atmSpvcVccStatsVciA INTEGER
  atmSpvcVccStatsIfB IntfIndex
  atmSpvcVccStatsVpiB INTEGER
  atmSpvcVccStatsVciB INTEGER
  atmSpvcVccStatsInCellCountHiA Integer32
  atmSpvcVccStatsInCellCountLoA Integer32
  atmSpvcVccStatsOutCellCountHiA Integer32
  atmSpvcVccStatsOutCellCountLoA Integer32
  atmSpvcVccStatsInCellCountHiB Integer32
  atmSpvcVccStatsInCellCountLoB Integer32
  atmSpvcVccStatsOutCellCountHiB Integer32
  atmSpvcVccStatsOutCellCountLoB Integer32
  atmSpvcVccStatsTimer Integer32
  atmSpvcVccStatsFrwdErrCrrctnRateA2B INTEGER
  atmSpvcVccStatsFrwdErrCrrctnRateB2A INTEGER
  atmSpvcVccStatsInOdometerCellCountHiA Integer32
  atmSpvcVccStatsInOdometerCellCountLoA Integer32
  atmSpvcVccStatsOutOdometerCellCountHiA Integer32
  atmSpvcVccStatsOutOdometerCellCountLoA Integer32
  atmSpvcVccStatsInOdometerCellCountHiB Integer32
  atmSpvcVccStatsInOdometerCellCountLoB Integer32
  atmSpvcVccStatsOutOdometerCellCountHiB Integer32
  atmSpvcVccStatsOutOdometerCellCountLoB Integer32
  atmSpvcVccStatsOdometerTimer Integer32
  atmSpvcVccStatsOdometerReset INTEGER
  atmSpvcVccStatsCellsDroppedA Integer32
  atmSpvcVccStatsCellsTaggedA Integer32
  atmSpvcVccStatsCellsDroppedB Integer32
  atmSpvcVccStatsCellsTaggedB Integer32

AtmArpEntry  
SEQUENCE    
  atmArpIpAddress IpAddress
  atmArpAtmAddress OCTET STRING
  atmArpAddrType INTEGER
  atmArpEntryState INTEGER
  atmArpEntryRowStatus RowStatus

AppIpRouteEntry  
SEQUENCE    
  appIpRouteDest IpAddress
  appIpRouteMask IpAddress
  appIpRouteMetric1 INTEGER
  appIpRouteNextHop IpAddress
  appIpRouteState INTEGER

IispCbrRoutEntry  
SEQUENCE    
  iispCbrRoutLength Integer32
  iispCbrRoutNsapAddr OCTET STRING
  iispCbrRoutIfIndex IntfIndex
  iispCbrRoutRowStatus RowStatus

IispVbrRoutEntry  
SEQUENCE    
  iispVbrRoutLength Integer32
  iispVbrRoutNsapAddr OCTET STRING
  iispVbrRoutIfIndex IntfIndex
  iispVbrRoutRowStatus RowStatus

IispCbrRouteEntry  
SEQUENCE    
  iispCbrRouteLength Integer32
  iispCbrRouteNsapAddr OCTET STRING
  iispCbrRouteIfIndex IntfIndex
  iispCbrRouteRowStatus RowStatus
  iispCbrRouteIfVuniId INTEGER
  iispCbrRouteDest Integer32
  iispCbrRouteType Integer32

IispVbrRouteEntry  
SEQUENCE    
  iispVbrRouteLength Integer32
  iispVbrRouteNsapAddr OCTET STRING
  iispVbrRouteIfIndex IntfIndex
  iispVbrRouteRowStatus RowStatus
  iispVbrRouteIfVuniId INTEGER
  iispVbrRouteDest Integer32
  iispVbrRouteType Integer32

FwReleaseEntry  
SEQUENCE    
  fwReleaseSlot INTEGER
  fwReleaseRunning OCTET STRING
  fwReleaseEpromVersion OCTET STRING
  fwReleaseCurrentVersion OCTET STRING
  fwReleaseNextVersion OCTET STRING
  fwReleaseUpdate INTEGER
  fwReleaseUpgrade INTEGER

MsgPoolViewEntry  
SEQUENCE    
  msgPoolViewIndex Integer32
  msgPoolViewTskId Integer32
  msgPoolViewTskName DisplayString
  msgPoolViewMsgCmd Integer32

Arp1Entry  
SEQUENCE    
  arp1CardSlot INTEGER
  arp1BridgeGroupNum INTEGER
  arp1IpAddress IpAddress
  arp1PhysicalAddr OCTET STRING
  arp1EntryAge Integer32

Arp2Entry  
SEQUENCE    
  arp2CardSlot INTEGER
  arp2BridgeGroupNum INTEGER
  arp2PhysicalAddr OCTET STRING
  arp2IpAddress IpAddress
  arp2EntryAge Integer32

BridgeCacheEntry  
SEQUENCE    
  bridgeCacheCardSlot INTEGER
  bridgeCacheBridgeGroupNum INTEGER
  bridgeCachePhysicalAddr OCTET STRING
  bridgeCacheType INTEGER
  bridgeCacheSourcePort INTEGER
  bridgeCacheEntryAge Integer32

OamActDeactEntry  
SEQUENCE    
  oamActDeactIfB IntfIndex
  oamActDeactVpiB INTEGER
  oamActDeactVciB INTEGER
  oamActDeactFuncType INTEGER
  oamActDeactDirFlow INTEGER
  oamActDeactFlowType INTEGER
  oamActDeactBlkSizeAB INTEGER
  oamActDeactBlkSizeBA INTEGER
  oamActDeactStsSrcPointEteCC INTEGER
  oamActDeactStsSnkPointEteCC INTEGER
  oamActDeactRsltPrevReq INTEGER
  oamActDeactRowStatus RowStatus
  oamActDeactStsSrcPointEtePM INTEGER
  oamActDeactStsSnkPointEtePM INTEGER
  oamActDeactStsSrcPointEtePMBR INTEGER
  oamActDeactStsSnkPointEtePMBR INTEGER
  oamActDeactBRBlockError INTEGER
  oamActDeactBRLostInsertedCell INTEGER
  oamActDeactBRMisInsertedCell INTEGER
  oamActDeactStsSrcPointSegPM INTEGER
  oamActDeactStsSnkPointSegPM INTEGER
  oamActDeactStsSrcPointSegPMBR INTEGER
  oamActDeactStsSnkPointSegPMBR INTEGER
  oamActDeactStsSrcPointSegCC INTEGER
  oamActDeactStsSnkPointSegCC INTEGER

OamLoopbackEntry  
SEQUENCE    
  oamLpbkIfB IntfIndex
  oamLpbkVpiB INTEGER
  oamLpbkVciB INTEGER
  oamLoopbackType INTEGER
  oamLpbkLocationID OCTET STRING
  oamLpbkAction INTEGER
  oamLpbkStatus INTEGER
  oamLpbkTxCount Integer32
  oamLpbkRxCount Integer32
  oamLpbkMismatchCount Integer32
  oamLpbkTimeout INTEGER

ViprRouterConfigEntry  
SEQUENCE    
  viprSlot Integer32
  viprRouterId INTEGER
  viprRouterName DisplayString
  viprRouterNoOfInterfaces INTEGER
  viprRouterNoOfRoutes INTEGER
  viprRouterAdminStatus INTEGER
  viprRouterOperStatus INTEGER
  viprRouterInitTmr Integer32
  viprRouterDisabWarnTmr Integer32
  viprRouterShutDwnWarnTmr Integer32
  viprRouterDisableWarning INTEGER
  viprRouterDisableReason INTEGER
  viprRouterRowStatus RowStatus

ViprIntfConfigEntry  
SEQUENCE    
  viprIntfId Integer32
  viprIntfIPAddress IpAddress
  viprIntfIPNetMask IpAddress
  viprIntfAdminStatus INTEGER
  viprIntfOperStatus INTEGER
  viprIntfInitTmr Integer32
  viprIntfDisabWarnTmr Integer32
  viprIntfShutDwnWarnTmr Integer32
  viprIntfDisableWarning INTEGER
  viprIntfDisableReason INTEGER
  viprIntfRipVersion INTEGER
  viprIntfRipMode INTEGER
  viprIntfRowStatus RowStatus
  viprIntfRipLineType INTEGER
  viprIntfAuthPasswd DisplayString

ViprSubChnlConfigEntry  
SEQUENCE    
  viprSubChnlId Integer32
  viprSubChnlIntfIndex IntfIndex
  viprSubChnlTrafficType INTEGER
  viprSubChnlLlcEncapType INTEGER
  viprSubChnlMacEncapType INTEGER
  viprSubChnlTosFeature INTEGER
  viprSubChnlTosValue INTEGER
  viprSubChnlTosMask INTEGER
  viprSubChnlVpiDlci INTEGER
  viprSubChnlVci INTEGER
  viprSubChnlSarType INTEGER
  viprSubChnlServiceType INTEGER
  viprSubChnlFwdErrCorrection INTEGER
  viprSubChnlInterworkingType INTEGER
  viprSubChnlFrameSize Integer32
  viprSubChnlComBurstSize Integer32
  viprSubChnlExcessBurstSize Integer32
  viprSubChnlCommitedInfoRate Integer32
  viprSubChnlTimeInterval INTEGER
  viprSubChnlAtmPeakCellRate Integer32
  viprSubChnlAtmSustainedCellRate Integer32
  viprSubChnlAtmMaxBurstSize Integer32
  viprSubChnlFrPeakCellRate Integer32
  viprSubChnlFrSustainedCellRate Integer32
  viprSubChnlFrMaxBurstSize Integer32
  viprSubChnlFlowType INTEGER
  viprSubChnlAdminStatus INTEGER
  viprSubChnlOperStatus INTEGER
  viprSubChnlInitTmr Integer32
  viprSubChnlDisabWarnTmr Integer32
  viprSubChnlShutDwnWarnTmr Integer32
  viprSubChnlDisableWarning INTEGER
  viprSubChnlDisableReason INTEGER
  viprSubChnlRowStatus RowStatus
  viprSubChnlImIpAddr IpAddress
  viprSubChnlImMask IpAddress
  viprSubChnlViB INTEGER
  viprSubChnlVUNIB INTEGER
  viprSubChnlTrafficShaping INTEGER
  viprSubChnlAtmOamStatus INTEGER

ViprRouteConfigEntry  
SEQUENCE    
  viprRouteId Integer32
  viprRouteIPAddress IpAddress
  viprRouteIPNetMask IpAddress
  viprRouteDestAddress IpAddress
  viprRouteGatewayAddress IpAddress
  viprRouteServiceType INTEGER
  viprRouteMetric Integer32
  viprRouteAdminStatus INTEGER
  viprRouteOperStatus INTEGER
  viprRouteInitTmr Integer32
  viprRouteDisabWarnTmr Integer32
  viprRouteShutDwnWarnTmr Integer32
  viprRouteDisableWarning INTEGER
  viprRouteDisableReason INTEGER
  viprRouteRowStatus RowStatus
  viprRouteDestMask IpAddress

ViprRoutingConfigEntry  
SEQUENCE    
  viprRoutingCommand INTEGER
  viprRoutingIPAddress IpAddress
  viprRoutingIPNetMask IpAddress
  viprRoutingDestAddress IpAddress
  viprRoutingGatewayAddress IpAddress
  viprRoutingServiceType INTEGER
  viprRoutingType INTEGER
  viprRoutingMetric Integer32
  viprRoutingDestMask IpAddress
  viprRoutingAge Integer32
  viprRoutingIndex Integer32

ViprArpConfigEntry  
SEQUENCE    
  viprArpCommand INTEGER
  viprArpIPAddress IpAddress
  viprArpHwAddress OCTET STRING
  viprArpEntryAge Integer32
  viprArpInterfaceIPAddress IpAddress
  viprArpInterfaceIPMask IpAddress
  viprArpInterfaceServiceType INTEGER
  viprArpIndex Integer32

ViprPingConfigEntry  
SEQUENCE    
  ipAddr IpAddress
  pingStatus INTEGER

ViprRipConfigEntry  
SEQUENCE    
  viprRipUpdateInt INTEGER

ViprVpnStatsEntry  
SEQUENCE    
  viprVpnStatsTimer Integer32
  viprVpnStatsIcmpOutEchoRPs Integer32
  viprVpnStatsIcmpOutDestURs Integer32
  viprVpnStatsIcmpOutSrcQ Integer32
  viprVpnStatsIcmpOutRedirects Integer32
  viprVpnStatsIcmpOutEchoRQs Integer32
  viprVpnStatsIcmpOutTimeXs Integer32
  viprVpnStatsIcmpOutParamps Integer32
  viprVpnStatsIcmpOutTimeRQs Integer32
  viprVpnStatsIcmpOutTimeRPs Integer32
  viprVpnStatsIcmpOutInfoRQs Integer32
  viprVpnStatsIcmpOutInfoRPs Integer32
  viprVpnStatsIcmpOutMaskRQs Integer32
  viprVpnStatsIcmpOutMaskRPs Integer32
  viprVpnStatsIcmpOutErrors Integer32
  viprVpnStatsIcmpInErrors Integer32
  viprVpnStatsIcmpInEchoRQs Integer32
  viprVpnStatsIcmpInAddrMasks Integer32
  viprVpnStatsIcmpInAddrMaskReps Integer32
  viprVpnStatsIcmpInEchoReps Integer32
  viprVpnStatsIcmpInDestUnreachs Integer32
  viprVpnStatsIcmpInSrcQuenchs Integer32
  viprVpnStatsIcmpInTimeExcds Integer32
  viprVpnStatsIcmpInParamProbs Integer32
  viprVpnStatsIcmpInTimeStamps Integer32
  viprVpnStatsIcmpInTimeStampsReps Integer32

ViprStatsEntry  
SEQUENCE    
  viprStatsReset INTEGER
  viprStatsPacketsRxHi Integer32
  viprStatsPacketsRxLo Integer32
  viprStatsPacketsTxHi Integer32
  viprStatsPacketsTxLo Integer32
  viprStatsMismatchCrcHi Integer32
  viprStatsMismatchCrcLo Integer32
  viprStatsInsufficientPcktsHi Integer32
  viprStatsInsufficientPcktsLo Integer32
  viprStatsExceedAal5CellsHi Integer32
  viprStatsExceedAal5CellsLo Integer32
  viprStatsPrototypeErrorsHi Integer32
  viprStatsPrototypeErrorsLo Integer32
  viprStatsArpProtoRxHi Integer32
  viprStatsArpProtoRxLo Integer32
  viprStatsIPInHdrErrorsHi Integer32
  viprStatsIPInHdrErrorsLo Integer32
  viprStatsIPInAddrErrorsHi Integer32
  viprStatsIPInAddrErrorsLo Integer32

ViprSubChnlStatsEntry  
SEQUENCE    
  viprSubChnlStatsInCellCountHiA Integer32
  viprSubChnlStatsInCellCountLoA Integer32
  viprSubChnlStatsOutCellCountHiA Integer32
  viprSubChnlStatsOutCellCountLoA Integer32
  viprSubChnlStatsInCellCountHiB Integer32
  viprSubChnlStatsInCellCountLoB Integer32
  viprSubChnlStatsOutCellCountHiB Integer32
  viprSubChnlStatsOutCellCountLoB Integer32
  viprSubChnlStatsTimer Integer32
  viprSubChnlStatsInOdometerCellCountHiA Integer32
  viprSubChnlStatsInOdometerCellCountLoA Integer32
  viprSubChnlStatsOutOdometerCellCountHiA Integer32
  viprSubChnlStatsOutOdometerCellCountLoA Integer32
  viprSubChnlStatsInOdometerCellCountHiB Integer32
  viprSubChnlStatsInOdometerCellCountLoB Integer32
  viprSubChnlStatsOutOdometerCellCountHiB Integer32
  viprSubChnlStatsOutOdometerCellCountLoB Integer32
  viprSubChnlStatsOdometerTimer Integer32
  viprSubChnlStatsOdometerReset INTEGER
  viprSubChnlStatsCellsDroppedB Integer32
  viprSubChnlStatsCellsTaggedB Integer32

VirtualIntfStatsEntry  
SEQUENCE    
  virtualIntfStatsIf IntfIndex
  virtualIntfStatsVi INTEGER
  virtualIntfStatsEgrCellCount Integer32
  virtualIntfStatsTimer Integer32
  virtualIntfStatsReset INTEGER

CardFwVerEntry  
SEQUENCE    
  cardFwVerSlot INTEGER
  cardFwVerType Integer32
  cardFwVerCurrent OCTET STRING
  cardFwVerCurrentIsDefault Integer32
  cardFwVerNext OCTET STRING
  cardFwVerNextIsDefault INTEGER
  cardFwDnldStatus INTEGER
  cardFwRetries Integer32

FwDriverEntry  
SEQUENCE    
  fwSlotId Integer32
  fwDriverType Integer32
  fwIsDefault Integer32
  fwDriverName OCTET STRING
  fwDriverFrn Integer32
  fwDriverSize Integer32
  fwDriverChecksum Integer32

AtmTrunkingRemoteIWFEntry  
SEQUENCE    
  atmTrunkingRemoteIWFIdentifier Integer32
  atmTrunkingRemoteIWFAddress OCTET STRING
  atmTrunkingRemoteIWFTrnkMode INTEGER
  atmTrunkingRemoteIWFAdminStatus INTEGER
  atmTrunkingRemoteIWFRowStatus RowStatus

AtmTrunkingSigVccEntry  
SEQUENCE    
  atmTrunkingSigVccRmtIWFIdentifier Integer32
  atmTrunkingSigVccIdentifier INTEGER
  atmTrunkingSigVccOutgoingIfIndex IntfIndex
  atmTrunkingSigVccOutgoingVpi INTEGER
  atmTrunkingSigVccOutgoingVci INTEGER
  atmTrunkingSigVccOwner INTEGER
  atmTrunkingSigVccInactiveTimer Integer32
  atmTrunkingSigVccType INTEGER
  atmTrunkingSigVccSignaling INTEGER
  atmTrunkingSigVccFwPcr01 Integer32
  atmTrunkingSigVccBwPcr01 Integer32
  atmTrunkingSigVccFwScr01 Integer32
  atmTrunkingSigVccBwScr01 Integer32
  atmTrunkingSigVccFwMbs01 Integer32
  atmTrunkingSigVccBwMbs01 Integer32
  atmTrunkingSigVccMaxAal2Vcc Integer32
  atmTrunkingSigVccActiveAal2Vcc Integer32
  atmTrunkingSigVccOperStatus Integer32
  atmTrunkingSigVccRowStatus RowStatus
  atmTrunkingSigVccViB INTEGER
  atmTrunkingSigVccVUNIB INTEGER
  atmTrunkingSigVccRetryTimer Integer32
  atmTrunkingSigVccRetryLimit Integer32
  atmTrunkingSigVccRestart INTEGER
  atmTrunkingSigVccPriority INTEGER
  atmTrunkingSigVccRetryCounter Integer32

AtmTrunkingBrVccConfigEntry  
SEQUENCE    
  atmTrunkingBrVccRmtIWFId Integer32
  atmTrunkingBrVccSigVccId INTEGER
  atmTrunkingBrVccId INTEGER
  atmTrunkingBrVccIf IntfIndex
  atmTrunkingBrVccVpi INTEGER
  atmTrunkingBrVccVci INTEGER
  atmTrunkingBrVccViB INTEGER
  atmTrunkingBrVccVUNIB INTEGER
  atmTrunkingBrVccServiceType INTEGER
  atmTrunkingBrVccSarType INTEGER
  atmTrunkingBrVccOwner INTEGER
  atmTrunkingBrVccOperStatus INTEGER
  atmTrunkingBrVccFwAtmPcr01 Integer32
  atmTrunkingBrVccBwAtmPcr01 Integer32
  atmTrunkingBrVccFwAtmScr01 Integer32
  atmTrunkingBrVccBwAtmScr01 Integer32
  atmTrunkingBrVccFwAtmMbs01 Integer32
  atmTrunkingBrVccBwAtmMbs01 Integer32
  atmTrunkingBrVccConnType INTEGER
  atmTrunkingBrVccActiveChanCnt Integer32
  atmTrunkingBrVccMaxAal2ChanId Integer32
  atmTrunkingBrVccCircuitModeDataSupp INTEGER
  atmTrunkingBrVccFrameModeSupp INTEGER
  atmTrunkingBrVccFaxModSupp INTEGER
  atmTrunkingBrVccCASPktXportSupp INTEGER
  atmTrunkingBrVccDTMFPktXportSupp INTEGER
  atmTrunkingBrVccMFR1PktXportSupp INTEGER
  atmTrunkingBrVccMFR2PktXportSupp INTEGER
  atmTrunkingBrVccPCMEncoding INTEGER
  atmTrunkingBrVccMaxFrameLength INTEGER
  atmTrunkingBrVccIdleChannSuprSupp INTEGER
  atmTrunkingBrVccSilenceDetSupp INTEGER
  atmTrunkingBrVccCompressionSpec INTEGER
  atmTrunkingBrVccAudioProfileSource INTEGER
  atmTrunkingBrVccAudioProfileId INTEGER
  atmTrunkingBrVccAvailBw INTEGER
  atmTrunkingBrVccRowStatus RowStatus
  atmTrunkingBrVccGr303Supp INTEGER
  atmTrunkingBrVccOamStatus INTEGER
  atmTrunkingBrVccInactiveTimer Integer32
  atmTrunkingBrVccRetryTimer Integer32
  atmTrunkingBrVccRetryLimit Integer32
  atmTrunkingBrVccRestart INTEGER
  atmTrunkingBrVccCuTimer INTEGER
  atmTrunkingBrVccPriority INTEGER
  atmTrunkingBrVccRetryCounter Integer32

AtmTrunkingDataChannelConfigEntry  
SEQUENCE    
  atmTrunkingDataChannelRmtIWFId Integer32
  atmTrunkingDataChannelSigVccId INTEGER
  atmTrunkingDataChannelBrVccId INTEGER
  atmTrunkingDataChannelId INTEGER
  atmTrunkingDataChanOperStatus INTEGER
  atmTrunkingDataChanOwner INTEGER
  atmTrunkingDataChanNBIntf IntfIndex

H248TermIdEntry  
SEQUENCE    
  h248TermSlotId INTEGER
  h248TermPhyPortId INTEGER
  h248TermLogPortId INTEGER
  h248TermChanId INTEGER
  h248TermVpi INTEGER
  h248TermVci INTEGER
  h248TermId OCTET STRING
  h248TermAal2Cid INTEGER
  h248TermActivation INTEGER
  h248TermRowStatus RowStatus

ProtectionGroupEntry  
SEQUENCE    
  pgtGroupId Integer32
  pgtSwitchoverMethod INTEGER
  pgtSwitchbackMethod INTEGER
  pgtStandbySelection INTEGER
  pgtRowStatus RowStatus

InterfaceProtectionEntry  
SEQUENCE    
  iptGroupId Integer32
  iptLogicalIntfId Integer32
  iptPhysicalIntfId Integer32
  iptOperState INTEGER
  iptIntfType INTEGER
  iptOperatingIntf Integer32
  iptProtCommand INTEGER
  iptSelectedStandby Integer32
  iptRowStatus RowStatus

Defined Values

lucent 3.1.1751
OBJECT IDENTIFIER    

mibs 3.1.1751.2
OBJECT IDENTIFIER    

acMIB 3.1.1751.2.18
Lucent Access Concentrator, Release 6.2
MODULE-IDENTITY    

sysConfig 3.1.1751.2.18.1
OBJECT IDENTIFIER    

equipConfig 3.1.1751.2.18.2
OBJECT IDENTIFIER    

channelConfig 3.1.1751.2.18.3
OBJECT IDENTIFIER    

intfConfig 3.1.1751.2.18.5
OBJECT IDENTIFIER    

connectionConfig 3.1.1751.2.18.6
OBJECT IDENTIFIER    

userServiceConfig 3.1.1751.2.18.7
OBJECT IDENTIFIER    

sysTraps 3.1.1751.2.18.8
OBJECT IDENTIFIER    

systemEvents 3.1.1751.2.18.8.1
OBJECT IDENTIFIER    

moduleEvents 3.1.1751.2.18.8.2
OBJECT IDENTIFIER    

interfaceEvents 3.1.1751.2.18.8.3
OBJECT IDENTIFIER    

connectionEvents 3.1.1751.2.18.8.4
OBJECT IDENTIFIER    

sysStatistics 3.1.1751.2.18.9
OBJECT IDENTIFIER    

equipStatistics 3.1.1751.2.18.10
OBJECT IDENTIFIER    

intfStatistics 3.1.1751.2.18.11
OBJECT IDENTIFIER    

connectionStatistics 3.1.1751.2.18.12
OBJECT IDENTIFIER    

ipAtmGroup 3.1.1751.2.18.13
OBJECT IDENTIFIER    

iispRouting 3.1.1751.2.18.14
OBJECT IDENTIFIER    

returnCode 3.1.1751.2.18.15
OBJECT IDENTIFIER    

sysControl 3.1.1751.2.18.16
OBJECT IDENTIFIER    

stratumConfig 3.1.1751.2.18.17
OBJECT IDENTIFIER    

cellTest 3.1.1751.2.18.18
OBJECT IDENTIFIER    

sysInfo 3.1.1751.2.18.19
OBJECT IDENTIFIER    

ethernetConfig 3.1.1751.2.18.20
OBJECT IDENTIFIER    

alarmConfig 3.1.1751.2.18.21
OBJECT IDENTIFIER    

sysTest 3.1.1751.2.18.22
OBJECT IDENTIFIER    

fwDriverSup 3.1.1751.2.18.23
OBJECT IDENTIFIER    

viprConfig 3.1.1751.2.18.24
OBJECT IDENTIFIER    

toneAnnceControl 3.1.1751.2.18.25
OBJECT IDENTIFIER    

gr303Config 3.1.1751.2.18.26
OBJECT IDENTIFIER    

gr303Stats 3.1.1751.2.18.27
OBJECT IDENTIFIER    

atmTrunkingMIBObjects 3.1.1751.2.18.28
OBJECT IDENTIFIER    

protectionGroup 3.1.1751.2.18.29
OBJECT IDENTIFIER    

h248Config 3.1.1751.2.18.30
OBJECT IDENTIFIER    

h248SysControl 3.1.1751.2.18.31
OBJECT IDENTIFIER    

siteName 3.1.1751.2.18.1.1
site name - ascii
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(20)  

siteID 3.1.1751.2.18.1.2
site id - numerical
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

siteEtherIpAddr 3.1.1751.2.18.1.3
ip address for ethernet access to the site (switch)
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

siteEtherIpMask 3.1.1751.2.18.1.4
ip mask for ethernet access to the site (switch)
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

siteGatewayAddr 3.1.1751.2.18.1.5
ip address for gateway access to the site (switch)
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

siteAtmAddrPrefix1 3.1.1751.2.18.1.6
This is one of the two atm address prefix of this switch.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(13)  

siteAtmAddrUser1 3.1.1751.2.18.1.7
This is one of the two atm address user part of this switch.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(7)  

siteRemoteMgrAddr1 3.1.1751.2.18.1.8
remote manager IP Address, where TRAP will be sent to.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

siteRemoteMgrAddr2 3.1.1751.2.18.1.9
remote manager IP Address, where TRAP will be sent to.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

siteRemoteMgrAddr3 3.1.1751.2.18.1.10
remote manager IP Address, where TRAP will be sent to.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

siteRemoteMgrAddr4 3.1.1751.2.18.1.11
remote manager IP Address, where TRAP will be sent to.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

siteRemoteMgrAddr5 3.1.1751.2.18.1.12
remote manager IP Address, where TRAP will be sent to.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

siteMasterNodeAtmAddr1 3.1.1751.2.18.1.13
Master node atm address, where TRAP will be sent to.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(20)  

siteMasterNodeAtmAddr2 3.1.1751.2.18.1.14
Master node atm address, where TRAP will be sent to.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(20)  

siteEnhanceFeatures 3.1.1751.2.18.1.15
enhancement features capability - number consists of a sum to represent the following: 1: securedAtm 2: isdn 4: frameRelay
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

siteTrapDialOutFeature 3.1.1751.2.18.1.16
Enables the dialing out to a remote terminal or beeper for trap notification.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), dialTerminal(2), dialBeeper(3)  

siteTrapDialOutPhoneNum 3.1.1751.2.18.1.17
Phone number of the terminal to dial when trap notifications are phoned out
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(20)  

siteTrapDialOutBeeperData 3.1.1751.2.18.1.18
Data (phone digits) to send to beeper if the dialBeeper option is selected.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(20)  

siteDateAndTime 3.1.1751.2.18.1.19
Current date and time: 11 octets octet# contents range ------ -------- ----- 1-2 year 0..65536 3 month 1..12 4 day 1..31 5 hour 0..23 6 minutes 0..59 7 seconds 0..60(60=leap second) 8 deci-seconds 0..9 9 direction from UTC '+'/'-' 10 hours from UTC 0..11 11 minutes from UTC 0..59
Status: current Access: read-write
OBJECT-TYPE    
  DateAndTime  

siteSoftwareVersion 3.1.1751.2.18.1.20
Constant value representing the version number of the current software.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(15)  

csTcpServerIpAddress 3.1.1751.2.18.1.21
The IP address of CS
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

csTcpServerPortNumber 3.1.1751.2.18.1.22
The Port Number used for communication with CS. NOTE: Port # 5000 and 6000 have been reservered for AC products. DO NOT USED THEM !!!
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1025..65535  

keepAliveTimer 3.1.1751.2.18.1.23
keep alive timer can be set inbetween 0 and 999999999
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..999999999  

inactiveTimer 3.1.1751.2.18.1.24
inactive timer can be set inbetween 0 and 999999999
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..999999999  

siteMasterNodeAddrType1 3.1.1751.2.18.1.25
Type of address specified for master node atm address, where TRAP will be sent to.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER nsap(1), e164(2), e164nsap(3)  

siteMasterNodeAddrType2 3.1.1751.2.18.1.26
Type of address specified for master node atm address, where TRAP will be sent to.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER nsap(1), e164(2), e164nsap(3)  

inBandPrimaryIpAddress 3.1.1751.2.18.1.27
IP address of the switch when the switch is accessed over the primary in-band connection.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

inBandPrimaryIpMask 3.1.1751.2.18.1.28
IP address subnet mask of the primary in-band management IP address.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

inBandBackupIpAddress 3.1.1751.2.18.1.29
IP address of the switch when the switch is accessed over the secondary in-band connection.
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

inBandBackupIpMask 3.1.1751.2.18.1.30
IP address subnet mask of the secondary in-band management IP address.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(4)  

inBandSvcConnectionsAllowed 3.1.1751.2.18.1.31
Flag indicating whether in-band management should be supported over SVCs.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

atmArpServer 3.1.1751.2.18.1.32
This flag indicates if this switch is an ATM ARP server.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

atmArpServerRemoteConnectionType 3.1.1751.2.18.1.33
When this switch is not the ATM ARP server, indicates whether the connection to the ATM ARP server uses SVCs or PVCs.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER svc(1), pvc(2)  

atmArpServerRemoteAtmAddress 3.1.1751.2.18.1.34
The ATM address of the ATM ARP server when this switch is not the ATM ARP server and the connection to the ATM ARP server uses SVCs.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(20)  

atmArpServerRemoteAddrType 3.1.1751.2.18.1.35
The format of the ATM address of the ATM ARP server when this switch is not the ATM ARP server and the connection to the ATM ARP server uses SVCs.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER nsap(1), e164(2), e164nsap(3)  

atmArpServerRemoteIpAddress 3.1.1751.2.18.1.36
The IP address of the ATM ARP server when this switch is not the ATM ARP server and the connection to the ATM ARP server uses PVCs.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

atmArpServerRemoteIpMask 3.1.1751.2.18.1.37
The IP address subnet mask of the ATM ARP server when this switch is not the ATM ARP server and the connection to the ATM ARP server uses PVCs.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

atmArpServerEncapsulation 3.1.1751.2.18.1.38
The type of encapsulation used for IP packets over ATM in in-band management.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER llc-snap(1)  

siteFallbackSoftwareVersion 3.1.1751.2.18.1.41
Constant value representing the version number of the software to fallback to.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(15)  

siteUpgradeSoftwareVersion 3.1.1751.2.18.1.42
Constant value representing the version number of the software to upgrade to.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(15)  

siteSwitchIpAddr 3.1.1751.2.18.1.43
IP Address for communication with the switch, regardless of which cpu is primary.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

muxTcpType 3.1.1751.2.18.1.44
The type of mux TCP.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER server(1), client(2)  

loopbackLocationID 3.1.1751.2.18.1.45
ID of the ATM Node where the loopback is to occur.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(16)  

oamDebouncingPeriod 3.1.1751.2.18.1.46
Debouncing period in milli seconds for clearing AIS/RDI state.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1000..300000  

svcPointToPointCalls 3.1.1751.2.18.1.47
The total number of SVC point-to-point calls, both legs are SVCs.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

svcPointToMultiPointCalls 3.1.1751.2.18.1.48
The total number of SVC point-to-multipoint calls, both legs are SVCs.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

svcPointToMultiPointParties 3.1.1751.2.18.1.49
The total number of parties on SVC point-to-multipoint calls, both legs are SVCs.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

spvcCePointToPointCalls 3.1.1751.2.18.1.50
The total number of circuit emulation SPVC calls.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

spvcTePointToPointCalls 3.1.1751.2.18.1.51
The total number of terminal emulation SPVC calls.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

spvcAtmPointToPointCalls 3.1.1751.2.18.1.52
The total number of ATM SPVC calls.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

cgApiCirEmCirEmPvcCalls 3.1.1751.2.18.1.53
The total number of circuit emulation to circuit emulation calls for Sapphire API.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

cgApiCirEmAtmPvcCalls 3.1.1751.2.18.1.54
The total number of circuit emulation to ATM calls for Sapphire APIs
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

cgApiAtmAtmPvcCalls 3.1.1751.2.18.1.55
The total number of ATM to ATM calls for Sapphire APIs
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

cgApiPointToPointSvcCalls 3.1.1751.2.18.1.56
The total number of point-to-point SVC calls for Sapphire APIs
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

cgApiPointToMultiPointSvcCalls 3.1.1751.2.18.1.57
The total number of point-to-multipoint SVC calls for Sapphire APIs
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

cgApiPointToMultiPointParties 3.1.1751.2.18.1.58
The total number of parties for Sapphire APIs
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

callContrlResAllocApply 3.1.1751.2.18.1.59
0 - not apply, 1 - apply the call control resouce allocation modification
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

callContrlResAllocUsage 3.1.1751.2.18.1.60
The percentage of memory usage for call control resource.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

siteFirmwarePatchNumber 3.1.1751.2.18.1.61
Constant value representing the patch number of the patch release.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

spvcActRestartAll 3.1.1751.2.18.1.62
Restart all ATM-to-ATM,CE-to-CE,TE-to-TE,FR-to-FR active unconnected spvc connections
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER spvcActAtmRestartAll(1), spvcActCeRestartAll(2), spvcActTeRestartAll(3), spvcActFrRestartAll(4)  

cgSvcCutThroughOption 3.1.1751.2.18.1.63
Cut Through option for SVC calls going to CG cgSvcAcImplicitCutThrough (1) - AC implicitly cuts through. cgSvcCgExplicitCutThrough (2) - CG sends explcit PATH_ETABLISH_REQ to request AC to cut through.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER cgSvcAcImplicitCutThrough(1), cgSvcCgExplicitCutThrough(2)  

sgApiCirEmEndPoints 3.1.1751.2.18.1.64
The total number of circuit emulation endpoints for Sapphire API.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sgApiAtmSvcEndPoints 3.1.1751.2.18.1.65
The total number of ATM SVC endpoints for Sapphire APIs
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

siteRemoteMgrSrcAddr1 3.1.1751.2.18.1.66
This is the source IP address used in all traps sent to remote manager
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ethernet(1), ibm(2), interface(3)  

siteRemoteMgrSrcAddr2 3.1.1751.2.18.1.67
This is the source IP address used in all traps sent to remote manager
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ethernet(1), ibm(2), interface(3)  

siteRemoteMgrSrcAddr3 3.1.1751.2.18.1.68
This is the source IP address used in all traps sent to remote manager
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ethernet(1), ibm(2), interface(3)  

siteRemoteMgrSrcAddr4 3.1.1751.2.18.1.69
This is the source IP address used in all traps sent to remote manager
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ethernet(1), ibm(2), interface(3)  

siteRemoteMgrSrcAddr5 3.1.1751.2.18.1.70
This is the source IP address used in all traps sent to remote manager
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ethernet(1), ibm(2), interface(3)  

spvcFrPointToPointCalls 3.1.1751.2.18.1.71
The total number of FR SPVC calls.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

inBandAppAtmAddress 3.1.1751.2.18.1.72
The ATM address of the inBand application
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(20)  

inBandAppAtmAddrType 3.1.1751.2.18.1.73
The format of the ATM address of the inBand application
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER nsap(1), e164(2), e164nsap(3)  

atmArpServer2RemoteAtmAddress 3.1.1751.2.18.1.74
The ATM address of the ATM ARP server when this switch is not the ATM ARP server and the connection to the ATM ARP server uses SVCs.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(20)  

atmArpServer2RemoteAddrType 3.1.1751.2.18.1.75
The format of the ATM address of the ATM ARP server when this switch is not the ATM ARP server and the connection to the ATM ARP server uses SVCs.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER nsap(1), e164(2), e164nsap(3)  

tasmMaxAnnceDiskSpace 3.1.1751.2.18.1.76
Specifies the maximum disk size in MBytes reserved for compressed announcements on the CPU hard disk.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..36  

tasmMaxAnnce 3.1.1751.2.18.1.77
Specifies the maximum number of tones and announcements that can be played simultaneously. This will depend on the number of control blocks allocated for collecting digits and for line tests as the memory comes from the same pool. The tasmControlBlockResAllocUsage field will be updated to indicate this.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..10000  

tasmMaxStdTones 3.1.1751.2.18.1.78
Specifies the maximum number of tones that can be played simutaneously. This field has been obsoleted for optimisation of resources.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..10  

tasmMemoryAction 3.1.1751.2.18.1.79
Specifies the action to be performed on the memory in the TASM card used for storing announcements.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER re-initialize(1)  

tasAnnceTable 3.1.1751.2.18.1.80
Table of announcements for the Tone Announcement server .
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TasAnnceEntry

tasAnnceEntry 3.1.1751.2.18.1.80.1
Row definition for Tone Announcement server table announcement entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  TasAnnceEntry  

tasAnnceId 3.1.1751.2.18.1.80.1.1
Announcement ID.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..100  

tasAnnceType 3.1.1751.2.18.1.80.1.2
The type of this announcement: voice indicates it is a pure voice announcement file. toneVoice indicates it is a file with tones at the beginning followed by voice. userTones indicates it is a file with purely user generated tones. music indicates it is a file with pure music. musicVoice indicates it is a file with music at the beginning followed by voice. toneMusic indicates it is a file with tones at the beginning followed by music.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER voice(1), toneVoice(2), userTones(3), music(4), musicVoice(5), toneMusic(6)  

tasAnnceCmprsType 3.1.1751.2.18.1.80.1.3
The type of compression used for storing this announcement: compress8k indicates 8k compression algorithm should be used. compress16k indicates 16k compression algorithm should be used. compress32k indicates 32k compression algorithm should be used.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER uncompressed(1), compress8k(2), compress16k(3), compress32k(4)  

tasAnnceValid 3.1.1751.2.18.1.80.1.4
Indicates the condition of this announcement, whether it is good, it is stored using an older compression algorithm, or it is corrupted.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER good(1), olderVersion(2), corrupted(3)  

tasAnnceDescription 3.1.1751.2.18.1.80.1.5
Description for this announcement.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(255)  

tasToneConfigTable 3.1.1751.2.18.1.81
Table of standard physical tone attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TasToneConfigEntry

tasToneConfigEntry 3.1.1751.2.18.1.81.1
Row definition for TASM announcement entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  TasToneConfigEntry  

tasToneId 3.1.1751.2.18.1.81.1.1
Tone ID.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..10  

tasToneType 3.1.1751.2.18.1.81.1.2
The type of this standard tone.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER dialTone(1), reorderTone(2), sitTone(3)  

tasToneFirstFreq 3.1.1751.2.18.1.81.1.3
The first frequency value for this tone.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

tasToneSecondFreq 3.1.1751.2.18.1.81.1.4
The second frequency value for this tone.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

tasToneThirdFreq 3.1.1751.2.18.1.81.1.5
The third frequency value for this tone.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

tasToneOnTime 3.1.1751.2.18.1.81.1.6
The on time in the tone duty cycle.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

tasToneOffTime 3.1.1751.2.18.1.81.1.7
The off time in the tone duty cycle.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

tasToneLevel 3.1.1751.2.18.1.81.1.8
The level of this tone in dBm.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmArpServerAtmAddr 3.1.1751.2.18.1.82
The ATM address of the ATM ARP server when this switch is configured as the ATM ARP server .
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(20)  

atmArpServerAddrType 3.1.1751.2.18.1.83
The format of the ATM address of the ATM ARP server when this switch is configured as the ATM ARP server.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER nsap(1), e164(2), e164nsap(3)  

spvcPointToMultiPointCalls 3.1.1751.2.18.1.84
The total number of SPVC point-to-multipoint calls
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

spvcPointToMultiPointParties 3.1.1751.2.18.1.85
The total number of parties on SPVC point-to-multipoint calls.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

consoleIPAddr1 3.1.1751.2.18.1.86
console IP Address, where TRAP will be sent.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

consoleIPAddr2 3.1.1751.2.18.1.87
console IP Address, where TRAP will be sent.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

consoleIPAddr3 3.1.1751.2.18.1.88
console IP Address, where TRAP will be sent.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

consolePort1 3.1.1751.2.18.1.89
port number on host where TRAP will be sent
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..32767  

consolePort2 3.1.1751.2.18.1.90
port number on host where TRAP will be sent
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..32767  

consolePort3 3.1.1751.2.18.1.91
port number on host where TRAP will be sent
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..32767  

featureTable 3.1.1751.2.18.1.92
Table of features to be turned on/off
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FeatureEntry

featureEntry 3.1.1751.2.18.1.92.1
Row definition for feature table
Status: current Access: not-accessible
OBJECT-TYPE    
  FeatureEntry  

featureId 3.1.1751.2.18.1.92.1.1
feature ID.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER pnni(1), gr303(2), vipr(3), h248(4)  

featureStaticMem 3.1.1751.2.18.1.92.1.2
Minimum memory required to run this feature
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

featureDesiredStatus 3.1.1751.2.18.1.92.1.3
To enable / disable this feature
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

featureCurrentStatus 3.1.1751.2.18.1.92.1.4
This feature is enabled / disabled
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

mediaGatewayControlType 3.1.1751.2.18.1.93
Choose to use H.248 protocol or sapphire protocol
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER sapphire(1), h248(2)  

dspResourceTable 3.1.1751.2.18.1.94
Table of DSP resource usage for the whole system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DspResourceEntry

dspResourceEntry 3.1.1751.2.18.1.94.1
Row definition for DSP resource usage table entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  DspResourceEntry  

dspResourceId 3.1.1751.2.18.1.94.1.1
DSP resource type enumerations. The algoSets describe the mode of the DSP card. Each mode corresponds to a set of algorithms supported by the IO card. Aal modes describe the aal type used. algoSet1-aal2-non-multiplexed: resource type for algoSet1 DSP mode and non-multiplexed aal2 AAL mode. algoSet1-aal2-std : resource type for algoSet1 DSP mode and standard aal2 AAL mode. algoSet2-aal2-non-multiplexed: resource type for algoSet2 DSP mode and non-multiplexed aal2 AAL mode.aal2 AAL mode. algoSet2-aal2-std: resource type for algoSet2 DSP mode and standard aal2 AAL mode. algoSet3-aal2-non-multiplexed: resource type for algoSet3 DSP mode and non-multiplexed aal2 AAL mode. algoSet3-aal2-std: resource type for algoSet3 DSP mode and standard aal2 AAL mode. algoSet5-aal1: resource type for algoSet5 DSP mode and aal1 AAL mode. algoSet6-aal2-std: resource type for algoSet6 DSP mode and standard aal2 AAL mode. tone-annce-cas: resource type for the tone announcement interface and CAS mode of the TASM card. tone-annce-tas: resource type for the tone announcement interface and TAS mode of the TASM card.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER algoSet1-aal2-non-multiplexed(1), algoSet1-aal2-std(2), algoSet2-aal2-non-multiplexed(3), algoSet2-aal2-std(4), algoSet3-aal2-non-multiplexed(5), algoSet3-aal2-std(6), algoSet5-aal1(7), algoSet6-aal2-std(8), tone-annce-cas(9), tone-annce-tas(10)  

dspResourceAvail 3.1.1751.2.18.1.94.1.2
The available DSP resource counts how many connections can be made using this available DSP resource type in the system.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

dspResourceUsed 3.1.1751.2.18.1.94.1.3
The used DSP resource counts how many connections are already made using this available DSP resource type in the system.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

dspResourceUsedFailed 3.1.1751.2.18.1.94.1.4
The used but failed DSP resource counts how many connections are already made using currently failed DSP resource type in the system.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

dspResourceAvailFailed 3.1.1751.2.18.1.94.1.5
The available but failed DSP resource counts how many connections can be made if using currently failed DSP resource type in the system.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tasmMaxDigitControlBlocks 3.1.1751.2.18.1.95
Specifies the maximum number of digit collection that can be initiated simultaneously. This will depend on the number of control blocks allocated for playing tones and announcements and for line tests as the memory comes from the same pool. The tasmControlBlockResAllocUsage field will be updated to indicate this .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..10000  

tasmMaxTestControlBlocks 3.1.1751.2.18.1.96
Specifies the maximum number of TDM line tests that can be initiated simultaneously. This will depend on the number of control blocks allocated for playing tones and announcements and for digit collection as the memory comes from the same pool. The tasmControlBlockResAllocUsage field will be updated to indicate this.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..10000  

tasmMaxMemResvd 3.1.1751.2.18.1.97
Specifies the maximum amount of memory in megabytes reserved for TASM.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tasmControlBlockResAllocUsage 3.1.1751.2.18.1.98
The percentage of memory usage for tones, announcements, digit collection and line tests control blocks.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tasmAnnceCacheMemResAllocUsage 3.1.1751.2.18.1.99
The percentage of memory usage for caching announcements in memory. Everytime an announcement is compressed this field will be updated to reflect the cache memory that will be taken up by this announcement. Once this field shows a 100 percent usage it is an indication to the user that any additional announcement will cause the system to thrash as it clears an announcement in cache to make room for the new announcement.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

siteAlternateGatewayAddr 3.1.1751.2.18.1.100
Alternate ip address of gateway to access the site (switch),Can be used only over the InBand PVC connection when the OAM is enabled on InBand PVCs
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

ipThrottlingConfig 3.1.1751.2.18.1.101
OBJECT IDENTIFIER    

ipThrottlingFeatureStatus 3.1.1751.2.18.1.101.1
CPU card IP throttling feature: off/on
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

ipThrottlingAllowedInFrameRate 3.1.1751.2.18.1.101.2
CPU card IP throttling: allowed input frames per second
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..20000  

ipThrottlingLeakyBucketSize 3.1.1751.2.18.1.101.3
CPU card IP throttling: the size of leaky bucket
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..20000  

ipThrottlingStatsOdometerTimer 3.1.1751.2.18.1.101.4
CPU card IP throttling: Number of seconds since odometer was reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipThrottlingStatsOdometerReset 3.1.1751.2.18.1.101.5
CPU card IP throttling: Odometer reset button.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reset(1)  

ipThrottlingInPackets 3.1.1751.2.18.1.101.6
CPU card IP throttling: the total number of input packets from both Ethernet port and In-band-mgmt of the CPU card.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipThrottlingInPacketsPassedEi 3.1.1751.2.18.1.101.7
CPU card IP throttling: the number of input packets passed through the Ethernet port of the CPU card.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipThrottlingInPacketsDroppedEi 3.1.1751.2.18.1.101.8
CPU card IP throttling: the number of input packets dropped from the Ethernet port of the CPU card.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipThrottlingInPacketsPassedIBM 3.1.1751.2.18.1.101.9
CPU card IP throttling: the number of input packets passed from the In-Band-Management of the CPU card.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipThrottlingInPacketsDroppedIBM 3.1.1751.2.18.1.101.10
CPU card IP throttling: the number of input packets dropped from the In-Band-Management of the CPU card.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

csSapphireInterfaceAddress 3.1.1751.2.18.1.102
The IP address to be specified as the source address in the TCP connect message that is sent to the SoftSwitch running as server and PSAX running as client.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

trapActivationTable 3.1.1751.2.18.1.103
Table of traps be turned on/off
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TrapActivationEntry

trapActivationEntry 3.1.1751.2.18.1.103.1
Row definition for trapActivation table
Status: current Access: not-accessible
OBJECT-TYPE    
  TrapActivationEntry  

trapGroupId 3.1.1751.2.18.1.103.1.1
trap group ID.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER systemEvents(1), moduleEvents(2), interfaceEvents(3), connectionEvents(4)  

trapIndex 3.1.1751.2.18.1.103.1.2
trap index in each group.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

trapActivationStatus 3.1.1751.2.18.1.103.1.3
activated: trap message activated. deactivated: trap message deactivated. permanently-activated: trap message can not be deactivated.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER activated(1), deactivated(2), permanently-activated(3)  

trapNames 3.1.1751.2.18.1.103.1.4
Name of the trap
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(50)  

resetAction 3.1.1751.2.18.1.103.1.5
set-all-active: set all trap active one group. set-all-deactive: set all trap deactive in a group.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER set-all-active(1), set-all-deactive(2)  

spvcGlobalPriorityScheme 3.1.1751.2.18.1.104
Flag indicating whether priority scheme should be supported across SPVCs and SPVC-trunks.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

spvcPriorityScheme 3.1.1751.2.18.1.105
Flag indicating whether priority scheme should be supported in SPVCs.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

spvcTrunkingPriorityScheme 3.1.1751.2.18.1.106
Flag indicating whether priority scheme should be supported in SPVC-trunks.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

atmTrunkVccs 3.1.1751.2.18.1.107
The total number of ATM Trunk VCCs (including SigVccs and Bearer Vccs).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmTrunkNarrowBandCalls 3.1.1751.2.18.1.108
The total number of ATM Trunking Narrow Band Calls supported
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

dspResourceFeatureConfig 3.1.1751.2.18.1.109
OBJECT IDENTIFIER    

dspReroutingFeature 3.1.1751.2.18.1.109.1
Dsp2 Rerouting Feature.This is used to enable or disable rerouting of connections when a dsp chip or card fails.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), auto-rerouting-enabled(2)  

cardTable 3.1.1751.2.18.2.1
Table of card configuration data
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CardEntry

cardEntry 3.1.1751.2.18.2.1.1
Row definition for ac120 card
Status: current Access: not-accessible
OBJECT-TYPE    
  CardEntry  

cardSlot 3.1.1751.2.18.2.1.1.1
Physical slot location. Valid range is a number between 1 and 24.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..24  

cardType 3.1.1751.2.18.2.1.1.2
Type of card in a physical slot. A specific type of card is associated with each number. none(1) no board present taxi(2) Taxi oC-3c(3) OC3 dS3-ATM(4) DS3 ATM dS1-CE(5) DS1 circuit emulation dS1-ATM(6) DS1 ATM e1-CE(7) E1 circuit emulation e3-ATM(8) E3 ATM highSpeed(9) High Speed Serial mSerial(10) Multi Serial dSP1(11) DSP tWStation(12) Two Wire Station tWOffice(13) Two Wire Office cPU(14) Central Processor Unit stratum(15) Stratum pwrSupply(16) Power Supply protectionCard(17) protection card e1-ATM(18) E1 ATM ethernet(19) Ethernet enhDS1(20) Enhanced DS1 enhE1(21) Enhanced E1 oC-3cMMAQ(22) OC3 Multimode Aqueman oC-3cMMTS(23) OC3 Multimode Traffic Shaping oC-3cSMAQ(24) OC3 Singlemode Aqueman oC-3cSMTS(25) OC3 Singlemode Traffic Shaping sTM-1SMAQ(26) STM1 Singlemode Aqueman sTM-1SMTS(27) STM1 Singlemode Traffic Shaping sTM-1MMAQ(28) STM1 Multimode Aqueman sTM-1MMTS(29) STM1 Multimode Traffic Shaping dS3-FR(30) DS3 Frame Relay dSP2A(31) DSP2 card revision 2A dS1-IMA(32) DS1 Inverse Multiplexing over ATM (IMA) I/O card e1-IMA(33) E1 IMA alarm(34) alarm card dSP2B(35) DSP card revision 2B aps-OC-3cSM(36) Automatic Protection Switching OC3 Single Mode aps-OC-3cMM(37) Automatic Protection Switching OC3 Multi Mode msp-STM-1SM(38) Multi Switch Protection STM1 Singemode msp-STM-1MM(39) Multi Switch Protection STM1 Multimode cH-DS3(40) Channelized DS3 cH-STS1(41) Channelized STS1 rT-S(42) Route Server cC-Server(43) Continuity Check Server hD-E1(44) High Density E1 hD-DS1(45) High Density DS1 dS3-IMA(46) DS3 IMA dSP2C(47) DSP card revision 2C tasm(48) Tone Announcement Service Module mD-DS1(49) Medium Density DS1 quadSerial(50) Quad Serial mD-DS1-IMA(51) Medium Density DS1 IMA mD-E1-IMA(52) Medium Density E1 IMA hD-DS1-IMA(53) High Density DS1 IMA hD-E1-IMA(54) High Density E1 IMA chDS3STS1-3P(55) 3-port channelized DS3 STS1 unstDS3E3-3P(56) 3-port unstructured DS3 E3 dS3E3-ATM-3P(57) 3-port DS3 E3 ATM oC12c-STM4-MM(58) OC12 STM4 Multimode oC12c-STM4-SM(59) OC12 STM4 Singlemode dSP2D(60) DSP card revision 2D ethernet-4P(61) 4-port Ethernet chDS3STS1-3P-Prot(62) 3-port channelized DS3 STS1 protection alarm-fan(63) alarm fan card dS1-Nx64CAS(64) DS1 card supporting N x 64 CAS
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), taxi(2), oC-3c(3), dS3-ATM(4), dS1-CE(5), dS1-ATM(6), e1-CE(7), e3-ATM(8), highSpeed(9), mSerial(10), dSP1(11), tWStation(12), tWOffice(13), cPU(14), stratum(15), pwrSupply(16), protectionCard(17), e1-ATM(18), ethernet(19), enhDS1(20), enhE1(21), oC-3cMMAQ(22), oC-3cMMTS(23), oC-3cSMAQ(24), oC-3cSMTS(25), sTM-1SMAQ(26), sTM-1SMTS(27), sTM-1MMAQ(28), sTM-1MMTS(29), dS3-FR(30), dSP2A(31), dS1-IMA(32), e1-IMA(33), alarm(34), dSP2B(35), aps-OC-3cSM(36), aps-OC-3cMM(37), msp-STM-1SM(38), msp-STM-1MM(39), cH-DS3(40), cH-STS1(41), rT-S(42), cC-Server(43), hD-E1(44), hD-DS1(45), dS3-IMA(46), dSP2C(47), tasm(48), mD-DS1(49), quadSerial(50), mD-DS1-IMA(51), mD-E1-IMA(52), hD-DS1-IMA(53), hD-E1-IMA(54), chDS3STS1-3P(55), unstDS3E3-3P(56), dS3E3-ATM-3P(57), oC12c-STM4-MM(58), oC12c-STM4-SM(59), dSP2D(60), ethernet-4P(61), chDS3STS1-3P-Prot(62), alarm-fan(63), dS1-Nx64CAS(64)  

cardProtectionStatus 3.1.1751.2.18.2.1.1.3
Current protection status of the card: none if the card is un-protected; protected if it is under the protection of another card; wrongType if the card types of protection card and protected card are different.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), protected(2), wrongType(3)  

cardOperStatus 3.1.1751.2.18.2.1.1.4
Current operational status of the card. For I/O card, it is primary if configured, it is unknown if unconfigured, or removed. For CPU, it is primary if the CPU is master CPU, or standby if the CPU is slave CPU.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER primary(1), standby(2), unknown(3)  

cardAdminStatus 3.1.1751.2.18.2.1.1.5
administrative status
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER switchProtection(1)  

cardAlarmStatus 3.1.1751.2.18.2.1.1.6
last alarm occurred
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), wrongCardType(2), lineFailed(3), cardRemoved(4), referenceClockFailed(5), compositeClockFailed(6), overload(7), plus5vFailed(8), plus120vFailed(9), minus48vFailed(10), unknownAlarm(11), completeClockFailed(12), backplaneCircuitryFailed(13), powerFailed(14), inputPortClkFailed(15)  

cardCleiCode 3.1.1751.2.18.2.1.1.7
CLEI code
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(10)  

cardRevision 3.1.1751.2.18.2.1.1.8
Card Revision number
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cardSerialNumber 3.1.1751.2.18.2.1.1.9
Serial Number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(12)  

cardOperatingMode 3.1.1751.2.18.2.1.1.10
Mode of operation for a card. This is applicable to those card types which can be configured in a dual mode. e.g. unstDS3E3-3P can be operational as either a 3 port DS3 or E3 card. All ports on the card will be of the same type depending on the card's operating mode.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), dS3(2), e3(3), sTS1e(4), oC12(5), sTM4(6)  

protectionConfigMode 3.1.1751.2.18.2.1.1.11
Protection Configuration Mode of a Card unprotected: Card is not in protection or protected state protection: Card is in protection state working: Card is in protected/working state and this state is read only and cannot be set by the user
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unprotected(1), protection(2), working(3)  

protectionStatus 3.1.1751.2.18.2.1.1.12
Protection Status of a card. Inservice and OutofService indicates if the card has failed or still operational. Active or Standby state indicates if it is carrying active traffic or not.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), inservice-Active(2), inservice-Standby(3), outOfService-Active(4), outOfService-Standby(5)  

protectionSlot 3.1.1751.2.18.2.1.1.13
If Protection Config Mode is Working then this field gives the protection slot.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..15  

taxiPortConfigTable 3.1.1751.2.18.2.2
Table of common physical Port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TaxiPortConfigEntry

taxiPortConfigEntry 3.1.1751.2.18.2.2.1
Row definition for common physical port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  TaxiPortConfigEntry  

taxiPortId 3.1.1751.2.18.2.2.1.1
interface index - SSPP
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

taxiPortType 3.1.1751.2.18.2.2.1.2
taxi type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER taxi100(1), taxi140(2)  

taxiLineStatus 3.1.1751.2.18.2.2.1.3
taxi line status: 1: NoAlarm 2: Loss of Signal
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

taxiOutputTransferRate 3.1.1751.2.18.2.2.1.4
User selectable parameter which allows the outgoing rate of the port to be reduced to 50% taxi, halfRate, only on AQueMan.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER fullRate(1), halfRate(2)  

ds3PortConfigTable 3.1.1751.2.18.2.3
Table of ds3 specific port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ds3PortConfigEntry

ds3PortConfigEntry 3.1.1751.2.18.2.3.1
Row definition for ds3 specific port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  Ds3PortConfigEntry  

ds3PortId 3.1.1751.2.18.2.3.1.1
slot/port: SSPP
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

ds3LineType 3.1.1751.2.18.2.3.1.2
This variable indicates the variety of DS3 C-bit implementing this interface. The type of interface affects the interpretation of the usage and error statistics. The rate of DS3 is 44.736 Mbps. The dsx3ClearChannel value means that the C-bits are not used except for sending/receiving AIS. The values, in sequence, describe: TITLE: SPECIFICATION: dsx3CbitParity ANSI T1.107a-1989 dsx3ClearChannel ANSI T1.102-1987.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER cbitParity(1), clearChannel(2), m13(3), m23(4)  

ds3LineCoding 3.1.1751.2.18.2.3.1.3
This variable describes the variety of Zero Code Suppression used on this interface, which in turn affects a number of its characteristics. ds3B3ZS refers to the use of specified patterns of normal bits and bipolar violations which are used to replace sequences of zero bits of a specified length.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER b3zs(1)  

ds3LoopbackConfig 3.1.1751.2.18.2.3.1.4
This variable represents the loopback configuration of the DS3 interface. See above diagrams for explanations of loops.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noLoop(1), localLoop(2), lineLoop(3), payloadLoop(4)  

ds3TransmitClockSource 3.1.1751.2.18.2.3.1.5
The source of Tranmit Clock. 'loopTiming' indicates that the recovered re- ceive clock is used as the transmit clock. 'localTiming' indicates that a local clock source is used. 'cardFreeRun' indicates that a local oscillator on the I/O card is used as the transmit clock. 'adaptiveTiming' indicates that the adaptive clocking mechanism is used
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER loopTiming(1), localTiming(2), cardFreeRun(3), adaptiveTiming(4)  

ds3LineStatus 3.1.1751.2.18.2.3.1.6
ds3 line status: 1: dsx3NoAlarm: No alarm present 2: dsx3RcvRAIFailure: Receiving Yellow/Remote Alarm Indication 4: dsx3XmitRAIAlarm: Transmitting Yellow/Remote Alarm Indication 8: dsx3RcvAIS: Receiving AIS failure state 16: dsx3XmitAIS: Transmitting AIS failure statue 32: dsx3LOF: Receiving LOF failure state 64: dsx3LOS: Reveiving LOS failure state 128: dsx3LoopbackState: Looping the received signal 256: dsx3RcvTestCode: Receiving a Test Pattern 512: dsx3OtherFailure: any line status not defined 1024: dsx3RcvRmtAIS: 2048: dsx3RcvRmtOOF: 4096: dsx3RcvRmtLOS: 8192: dsx3RcvRmtIdle: 16384: dsx3RmtLoopback: Far end remote loopback
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..32767  

ds3LineBuildOut 3.1.1751.2.18.2.3.1.7
ds3 line build out
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER short(1), long(2)  

ds3LineScramble 3.1.1751.2.18.2.3.1.8
ds3 line scramble
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ds3CellMapping 3.1.1751.2.18.2.3.1.9
ds3 cell mapping method
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER plcp(1), directMapping(2)  

ds3SendCode 3.1.1751.2.18.2.3.1.10
This variable indicates what type of code is being sent across the ds3 interface by the device. The values mean: 'noCode' - sending looped or normal data 'lineLoopCode' - sending a request for a line loopback 'deactivateCode' - sending a loopback deactivation request 'testPattern' - sending a test pattern
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noCode(1), lineLoopCode(2), deactivateCode(3), testPattern(4)  

ds3OutputTxRate 3.1.1751.2.18.2.3.1.11
The ability to adjust the bandwidth of DS3 in tx direction. The adjustable DS3 bandwidth will support 1% increments.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..100  

msPortConfigTable 3.1.1751.2.18.2.4
Table of multi-serial card's port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MsPortConfigEntry

msPortConfigEntry 3.1.1751.2.18.2.4.1
Row definition for multi-serial port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  MsPortConfigEntry  

msPortId 3.1.1751.2.18.2.4.1.1
slot/port: SSPP
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

msLineCoding 3.1.1751.2.18.2.4.1.2
Line Coding.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER nrz(1)  

msBaudRate 3.1.1751.2.18.2.4.1.3
baud rate is determined by multiplying this number by the msBaudRateMultiplier
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER baud300(1), baud600(2), baud900(3), baud1200(4), baud1800(5), baud2400(6), baud3600(7), baud4800(8), baud7200(9), baud9600(10), baud14400(11), baud19200(12), baud28800(13), baud38400(14), baud57600(15), baud76800(16), baud115200(17), baud16k(18), baud32k(19), baud56k(20), baud64k(21), baud112k(22), baud128k(23), baud168k(24), baud192k(25), baud224k(26), baud256k(27), baud280k(28), baud320k(29), baud336k(30), baud384k(31), baud392k(32), baud448k(33), baud504k(34), baud512k(35), baud560k(36), baud576k(37), baud616k(38), baud640k(39), baud672k(40), baud704k(41), baud728k(42), baud768k(43), baud784k(44), baud832k(45), baud840k(46), baud896k(47), baud952k(48), baud960k(49), baud1008k(50), baud1024k(51), baud1064k(52), baud1088k(53), baud1120k(54), baud1152k(55), baud1176k(56), baud1216k(57), baud1232k(58), baud1280k(59), baud1288k(60), baud1344k(61), baud1400k(62), baud1408k(63), baud1456k(64), baud1472k(65), baud1512k(66), baud1536k(67), baud1568k(68), baud1600k(69), baud1624k(70), baud1664k(71), baud1680k(72), baud1728k(73), baud1736k(74), baud1792k(75), baud1856k(76), baud1920k(77), baud1984k(78), baud2048k(79), baud75(80), baud1848k(81), baud1904k(82), baud1960k(83), baud2016k(84), baud2072k(85), baud2112k(86), baud2128k(87), baud2176k(88), baud2184k(89), baud2240k(90), baud2296k(91), baud2304k(92), baud2352k(93), baud2368k(94), baud2408k(95), baud2432k(96), baud2464k(97), baud2496k(98), baud2520k(99), baud2560k(100), baud2576k(101), baud2624k(102), baud2632k(103), baud2688k(104), baud2744k(105), baud2752k(106), baud2800k(107), baud2816k(108), baud2856k(109), baud2880k(110), baud2912k(111), baud2944k(112), baud2968k(113), baud3008k(114), baud3024k(115), baud3072k(116), baud3080k(117), baud3136k(118), baud3192k(119), baud3200k(120), baud3248k(121), baud3264k(122), baud3304k(123), baud3328k(124), baud3360k(125), baud3392k(126), baud3416k(127), baud3456k(128), baud3472k(129), baud3520k(130), baud3528k(131), baud3584k(132), baud3640k(133), baud3648k(134), baud3696k(135), baud3712k(136), baud3752k(137), baud3776k(138), baud3808k(139), baud3840k(140), baud3864k(141), baud3904k(142), baud3920k(143), baud3968k(144), baud3976k(145), baud4032k(146), baud4088k(147), baud4096k(148), baud4144k(149), baud4160k(150), baud4200k(151), baud4224k(152), baud4256k(153), baud4288k(154), baud4312k(155), baud4352k(156), baud4368k(157), baud4416k(158), baud4424k(159), baud4480k(160), baud4536k(161), baud4544k(162), baud4592k(163), baud4608k(164), baud4648k(165), baud4672k(166), baud4704k(167), baud4736k(168), baud4760k(169), baud4800k(170), baud4816k(171), baud4864k(172), baud4872k(173), baud4928k(174), baud4984k(175), baud4992k(176), baud5040k(177), baud5056k(178), baud5096k(179), baud5120k(180), baud5152k(181), baud5184k(182), baud5208k(183), baud5248k(184), baud5264k(185), baud5312k(186), baud5320k(187), baud5376k(188), baud5432k(189), baud5440k(190), baud5488k(191), baud5504k(192), baud5544k(193), baud5568k(194), baud5600k(195), baud5632k(196), baud5656k(197), baud5696k(198), baud5712k(199), baud5760k(200), baud5768k(201), baud5824k(202), baud5880k(203), baud5888k(204), baud5936k(205), baud5952k(206), baud5992k(207), baud6016k(208), baud6048k(209), baud6080k(210), baud6104k(211), baud6144k(212), baud6160k(213), baud6208k(214), baud6216k(215), baud6272k(216), baud6328k(217), baud6336k(218), baud6384k(219), baud6400k(220), baud6440k(221), baud6464k(222), baud6496k(223), baud6528k(224), baud6552k(225), baud6592k(226), baud6608k(227), baud6656k(228), baud6664k(229), baud6720k(230), baud6776k(231), baud6784k(232), baud6832k(233), baud6848k(234), baud6888k(235), baud6912k(236), baud6944k(237), baud6976k(238), baud7000k(239), baud7040k(240), baud7056k(241), baud7104k(242), baud7112k(243), baud7168k(244), baud7224k(245), baud7232k(246), baud7280k(247), baud7296k(248), baud7336k(249), baud7360k(250), baud7392k(251), baud7424k(252), baud7448k(253), baud7488k(254), baud7504k(255), baud7552k(256), baud7560k(257), baud7616k(258), baud7680k(259), baud7672k(260), baud7728k(261), baud7744k(262), baud7784k(263), baud7808k(264), baud7840k(265), baud7872k(266), baud7896k(267), baud7936k(268), baud7952k(269), baud8000k(270), baud8008k(271), baud8064k(272), baud8120k(273), baud8128k(274), baud8176k(275), baud8192k(276), baud8232k(277), baud8256k(278), baud8288k(279), baud8320k(280), baud8344k(281), baud8384k(282), baud8400k(283), baud8448k(284), baud8456k(285), baud8512k(286), baud8568k(287), baud8576k(288), baud8624k(289), baud8640k(290), baud8680k(291), baud8704k(292), baud8736k(293), baud8768k(294), baud8792k(295), baud8832k(296), baud8848k(297), baud8896k(298), baud8904k(299), baud8960k(300), baud9016k(301), baud9024k(302), baud9072k(303), baud9088k(304), baud9128k(305), baud9152k(306), baud9184k(307), baud9216k(308), baud9240k(309), baud9280k(310), baud9296k(311), baud9344k(312), baud9352k(313), baud9408k(314), baud9464k(315), baud9472k(316), baud9520k(317), baud9536k(318), baud9576k(319), baud9600k(320), baud9632k(321), baud9664k(322), baud9688k(323), baud9728k(324), baud9744k(325), baud9792k(326), baud9800k(327), baud9856k(328), baud9912k(329), baud9920k(330), baud9968k(331), baud9984k(332), baud10024k(333), baud10048k(334), baud10080k(335), baud10112k(336), baud10136k(337), baud10176k(338), baud10192k(339), baud10240k(340), baud10248k(341), baud10304k(342), baud10360k(343), baud10368k(344), baud10416k(345), baud10432k(346), baud10472k(347), baud10496k(348), baud10528k(349), baud10560k(350), baud10584k(351), baud10624k(352), baud10640k(353), baud10688k(354), baud10696k(355), baud10752k(356), baud10808k(357), baud10816k(358), baud10864k(359), baud10880k(360), baud10920k(361), baud10944k(362), baud10976k(363), baud11008k(364), baud11032k(365), baud11072k(366), baud11088k(367), baud11136k(368), baud11144k(369), baud11200k(370), baud11256k(371), baud11264k(372), baud11312k(373), baud11328k(374), baud11368k(375), baud11392k(376), baud11424k(377), baud11456k(378), baud11480k(379), baud11520k(380), baud11536k(381), baud11584k(382), baud11592k(383), baud11648k(384), baud11704k(385), baud11712k(386), baud11760k(387), baud11776k(388), baud11816k(389), baud11840k(390), baud11872k(391), baud11904k(392), baud11928k(393), baud11968k(394), baud11984k(395), baud12032k(396), baud12040k(397), baud12096k(398), baud12152k(399), baud12160k(400), baud12208k(401), baud12224k(402), baud12264k(403), baud12288k(404), baud12320k(405), baud12352k(406), baud12376k(407), baud12416k(408), baud12432k(409), baud12480k(410), baud12488k(411), baud12544k(412), baud12600k(413), baud12608k(414), baud12656k(415), baud12672k(416), baud12712k(417), baud12736k(418), baud12768k(419), baud12800k(420), baud12824k(421), baud12864k(422), baud12880k(423), baud12928k(424), baud12936k(425), baud12992k(426), baud13048k(427), baud13056k(428), baud13104k(429), baud13120k(430), baud13160k(431), baud13184k(432), baud13216k(433), baud13248k(434), baud13272k(435), baud13312k(436), baud13328k(437), baud13376k(438), baud13384k(439), baud13440k(440), baud13496k(441), baud13504k(442), baud13552k(443), baud13568k(444), baud13608k(445), baud13632k(446), baud13664k(447), baud13696k(448), baud13720k(449), baud13760k(450), baud13776k(451), baud13824k(452), baud13832k(453), baud13888k(454), baud13944k(455), baud13952k(456), baud14000k(457), baud14016k(458), baud14056k(459), baud14080k(460), baud14112k(461), baud14144k(462), baud14168k(463), baud14208k(464), baud14224k(465), baud14272k(466), baud14280k(467), baud14336k(468), baud14400k(469), baud14464k(470), baud14528k(471), baud14592k(472), baud14656k(473), baud14720k(474), baud14784k(475), baud14848k(476), baud14912k(477), baud14976k(478), baud15040k(479), baud15104k(480), baud15168k(481), baud15232k(482), baud15296k(483), baud15360k(484), baud15424k(485), baud15488k(486), baud15552k(487), baud15616k(488), baud15680k(489), baud15744k(490), baud15808k(491), baud15872k(492), baud15936k(493), baud16000k(494), baud16064k(495), baud16128k(496), baud16192k(497), baud16256k(498), baud16320k(499), baud16384k(500), baud1544k(501), baud230400(502), baud150(503)  

msProtocol 3.1.1751.2.18.2.4.1.4
protocol type for serial port
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER rs232(1), rs449(2), rs530(3), v35(4), x21(5), kg(6), rs530A(7)  

msEquipmentType 3.1.1751.2.18.2.4.1.5
Equipment type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER dte(1), dce(2)  

msRs232XmitMode 3.1.1751.2.18.2.4.1.6
transmit mode for rs232 DTE/DCE serial port
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER synchronous(1), asynchronous(2)  

msRs232Parity 3.1.1751.2.18.2.4.1.7
parity for rs232 DTE/DCE serial port
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), odd(2), even(3)  

msRs232DataBits 3.1.1751.2.18.2.4.1.8
data bits for rs232 DTE/DCE serial port
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER eight(1), seven(2), six(3)  

msRs232StopBits 3.1.1751.2.18.2.4.1.9
stop bits for rs232 DTE/DCE serial port
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER one(1), two(2)  

msTxDataClkSrcForDte 3.1.1751.2.18.2.4.1.10
Transmit data clock source for DTE, externalTx in is not valid for rs232. This field is ignored if the local side is DCE.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER localTiming(1), txRxTiming(2), txTiming(3)  

msTxDataClkSrcForDce 3.1.1751.2.18.2.4.1.11
Transmit data clock source for DCE localTiming: a local clock source is used. (e.g., from backplane (stratum) loopTiming: from remote This field is ignored if the local side is DTE
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER localTiming(1), loopTiming(2)  

msRxDataClkSrcForDce 3.1.1751.2.18.2.4.1.12
Receive data clock source for DCE localTiming: a local clock source is used. (e.g., from backplane (stratum) loopTiming: from remote This field is ignored if the local side is DTE
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER localTiming(1), externalTiming(2)  

msRxClkPolarity 3.1.1751.2.18.2.4.1.13
Whether or not to reverse the receive clock
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER standard(1), inverted(2)  

msTxClkPolarity 3.1.1751.2.18.2.4.1.14
Whether or not to reverse the transmit clock
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER standard(1), inverted(2)  

msKgResync 3.1.1751.2.18.2.4.1.15
Turn KG resync on/off
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

msHandshake 3.1.1751.2.18.2.4.1.16
Multiserial Module handshake: observed : used with AAL1 to monitor RTS/CTS exchange.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER observed(1), ignored(2)  

msSpeedAdaption 3.1.1751.2.18.2.4.1.17
The state of allowing speed adaption
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

msBitStuffing 3.1.1751.2.18.2.4.1.18
When msBitStuffing is enabled, CAC throughput is (1 + 1/7) user throughtput. Otherwise the CAC throughput is the same as the user throughput. msBitStuffing can only be enabled for circuit emulation interfaces.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

msLineStatus 3.1.1751.2.18.2.4.1.19
line status on the port: The msLineStatus is a bit map representation. It can represent multiple failures (alarms) if supported by the card. NoAlarm should be set if and only if no other flag is set. The various bit positions are: 1: NoAlarm 2: Loss of Signal
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

msRxDataPolarity 3.1.1751.2.18.2.4.1.20
Whether or not to reverse the receive data
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER standard(1), inverted(2)  

msTxDataPolarity 3.1.1751.2.18.2.4.1.21
Whether or not to reverse the transmit data
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER standard(1), inverted(2)  

msLoopbackConfig 3.1.1751.2.18.2.4.1.22
This variable represents the loopback configuration of the Serial port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noLoop(1), localLoop(2), lineLoop(3)  

msLOSDetection 3.1.1751.2.18.2.4.1.23
State of detection of LOS by IO card. LOS detection is always enabled when msBitStuffing is enabled. When the interface is not circuit emulation, the IO card does not report any LOS.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

ds1PortConfigTable 3.1.1751.2.18.2.5
Table of ds1 specific port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ds1PortConfigEntry

ds1PortConfigEntry 3.1.1751.2.18.2.5.1
Row definition for ds1 specific port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  Ds1PortConfigEntry  

ds1PortId 3.1.1751.2.18.2.5.1.1
interface index - slot/port: SSPP
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

ds1Channelization 3.1.1751.2.18.2.5.1.2
ds1 interface type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

ds1LineType 3.1.1751.2.18.2.5.1.3
ds1 interface type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER esf(1), d4(2)  

ds1LineCoding 3.1.1751.2.18.2.5.1.4
ds1 interface type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER b8zs(1), ami(2)  

ds1LoopbackConfig 3.1.1751.2.18.2.5.1.5
This variable represents the loopback configuration of the ds1 interface
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noLoop(1), localLoop(2), lineLoop(3), payloadLoop(4)  

ds1TransmitClockSource 3.1.1751.2.18.2.5.1.6
ds1 timing source
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER loopTiming(1), localTiming(2), adaptive(3)  

ds1LineBuildOut 3.1.1751.2.18.2.5.1.7
ds1 line build out
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER upTo133Feet(1), upTo266Feet(2), upTo399Feet(3), upTo533Feet(4), upTo655Feet(5), negative7-5Db(6), negative15Db(7), negative22-5Db(8)  

ds1LineStatus 3.1.1751.2.18.2.5.1.8
This variable indicates the Line Status of the interface. It contains loopback, failure, re- ceived 'alarm' and transmitted 'alarm' infor- mation. The dsx1LineStatus is a bit map represented as a sum, therefore, it can represent multiple failures (alarms) and a LoopbackState simultaneously. ds1NoAlarm should be set if and only if no other flag is set. If the ds1LoopbackState bit is set, the loopbak in effect can be determined from the ds1LoopbackConfig object. The various bit positions are: 1: dsx1NoAlarm: No Alarm Present 2: dsx1RcvFarEndLOF: Far end LOF (a.k.a., Yellow Alarm) 4: dsx1XmtFarEndLOF: Near end sending LOF Indication 8: dsx1RcvAIS: Far end sending AIS 16: dsx1XmtAIS: Near end sending AIS 32: dsx1LossOfFrame: Near end LOF (a.k.a., Red Alarm) 64: dsx1LossOfSignal: Near end Loss Of Signal 128: dsx1LoopbackState: Near end is looped 256: dsx1T16AIS: E1 TS16 AIS 512: dsx1RcvFarEndLOMF: Far End Sending TS16 LOMF 1024: dsx1XmtFarEndLOMF: Near End Sending TS16 LOMF 2048: dsx1RcvTestCode: Near End detects a test code 4096: dsx1OtherFailure: any line status not defined here 8192: dsx1RmtLoopback: Far end loopback
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..16383  

ds1EnhanceFeatureSet1 3.1.1751.2.18.2.5.1.10
To enable/disable a proprietary ab signaling scheme, it applies to all DS0s in the port. No individual DS0 signaling can be configured under this scheme.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

ds1DataTransferType 3.1.1751.2.18.2.5.1.11
DS1 data transfer type is only applicable in Circuit Emulation where unstructured CE packets entire T1 frame including the F-bit into the AAL1 for data tranfer, whereas, the structured CE packets the entire T1 frame except the F-bit.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER structured(1), unstructured(2)  

ds1OamInterworkingType 3.1.1751.2.18.2.5.1.12
Specifies whether the interworking is done by trunk conditioning or unframed1s
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER trunkCond(1), unframed1s(2)  

ds1ConnGatewayFeature 3.1.1751.2.18.2.5.1.14
To enable/disable connection gateway (Sapphire) API.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

ds1InLineCode 3.1.1751.2.18.2.5.1.15
To select and support the inlinecode option in either ANSI or DS1_ANI (ANI: Access Network Interface)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER aNSI(1), ds1-ANI(2)  

oc3PortConfigTable 3.1.1751.2.18.2.6
Table of common physical Port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Oc3PortConfigEntry

oc3PortConfigEntry 3.1.1751.2.18.2.6.1
Row definition for common physical port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  Oc3PortConfigEntry  

oc3PortId 3.1.1751.2.18.2.6.1.1
interface index - SSPP
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

oc3LoopbackConfig 3.1.1751.2.18.2.6.1.2
This variable represents the loopback configuration of the OC3 interface See above diagrams for explanations of loops.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noLoop(1), localLoop(2), lineLoop(3)  

oc3TransmitClockSource 3.1.1751.2.18.2.6.1.3
The source of Tranmit Clock. 'loopTiming' indicates that the recovered re- ceive clock is used as the transmit clock. 'localTiming' indicates that a local clock source is used.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER loopTiming(1), localTiming(2)  

oc3LineStatus 3.1.1751.2.18.2.6.1.4
oc3 line status - 1: oc3NoAlarm: No alarm present 2: oc3RcvRAIFailure: Receiving Yellow/Remote Alarm Indication 4: oc3XmitRAIAlarm: Transmitting Yellow/Remote Alarm Indication 8: oc3RcvAIS: Receiving AIS failure state 16: oc3XmitAIS: Transmitting AIS failure statue 32: oc3LOF: Receiving LOF failure state 64: oc3LOS: Reveiving LOS failure state 128: oc3LoopbackState: Looping the received signal 256: oc3RcvTestCode: Receiving a Test Pattern 512: oc3OtherFailure: any line status not defined 1024: oc3LCD: Receiving Loss Of Cell Delineation 2048: oc3LRDI: Receiving Line RDI failure state 4096: oc3PRDI: Receiving Path RDI failure state
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..8191  

oc3OutputTransferRate 3.1.1751.2.18.2.6.1.5
User selectable parameter which allows the outgoing rate of the port to be reduced to 50% oc3, halfRate, only on AQueMan.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER fullRate(1), halfRate(2)  

oc3APSConfiguration 3.1.1751.2.18.2.6.1.6
Indicates whether APS is configured for this port .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unprotected(1), working(2), protection(3)  

oc3APS 3.1.1751.2.18.2.16
OBJECT IDENTIFIER    

oc3APSPairConfigTable 3.1.1751.2.18.2.16.1
Table of common physical Port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Oc3APSPairConfigEntry

oc3APSPairConfigEntry 3.1.1751.2.18.2.16.1.1
Row definition for common physical port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  Oc3APSPairConfigEntry  

oc3APSPairId 3.1.1751.2.18.2.16.1.1.1
APS Pair Port index - SSPP
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

oc3APSPairMode 3.1.1751.2.18.2.16.1.1.2
Unidirectional or Bidirectional mode: Uni - Each pair operates independently i.e. a switch over in one pair does not effect the remote pair. Bi - both remote and local pairs have to switch together.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unidirectional(1), bidirectional(2)  

oc3APSPairOption 3.1.1751.2.18.2.16.1.1.3
Nonrevertive - After a switch to Prot port, even if the working comes up there is no switch to the working port back. Revertive - traffic is switched back to work port after it comes back.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER nonrevertive(1), revertive(2)  

oc3APSPairWorkingSFBERThreshold 3.1.1751.2.18.2.16.1.1.4
Bits error Rate threshold to declare signal failure
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER tenToMinus4(1), tenToMinus5(2)  

oc3APSPairProtectionSFBERThreshold 3.1.1751.2.18.2.16.1.1.6
Bits error Rate threshold to declare signal failure
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER tenToMinus4(1), tenToMinus5(2)  

oc3APSPairWorkingSDBERThreshold 3.1.1751.2.18.2.16.1.1.5
Bits error Rate threshold to declare signal degrade
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER tenToMinus5(1), tenToMinus6(2), tenToMinus7(3), tenToMinus8(4)  

oc3APSPairProtectionSDBERThreshold 3.1.1751.2.18.2.16.1.1.7
Bits error Rate threshold to declare signal degrade
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER tenToMinus5(1), tenToMinus6(2), tenToMinus7(3), tenToMinus8(4)  

oc3APSPairWTRPeriod 3.1.1751.2.18.2.16.1.1.8
Duration for Wait To Restore Period between 5 to 12 minutes. Ref: BellCore GR-253-Core, Issue 3, page 200, R5-56.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 5..12  

oc3APSWorkingSlot 3.1.1751.2.18.2.16.1.1.9
Working slot of APS pair.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

oc3APSProtectionSlot 3.1.1751.2.18.2.16.1.1.10
Protection slot of APS pair.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

oc3APSActiveSlot 3.1.1751.2.18.2.16.1.1.11
Active slot of APS pair.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

oc3APSPairStatus 3.1.1751.2.18.2.16.1.1.12
noFailure : The protection line is not in use. modeMismatch : one end is configured unidirectional and the other is bidirectional (both the ends should be configured in the same mode). Also when one end is configured for 1:1 architechture and the other end indicates it is configured for 1:n architechture.(Bidirectional mode only) swByteFailure: protection switching byte failure - defect declared when invalid / persistantly unacceptable codes are received in the K1 byte. failure declared if defect persists for an extended period. Invalid code is when the incoming K1 byte contains an unused code or a code irrelevant for the specific switching operation.(Only in bi-directional mode) chMismatch : channel mismatch is declared when the channel numbers in the transmitted K1 byte and the received K2 byte do not match for 50 ms.Channel mismatch is monitored only in bidirectional mode.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noFailure(1), modeMismatch(2), swByteFailure(3), chMismatch(4)  

oc3APSPairUserCommand 3.1.1751.2.18.2.16.1.1.13
APS Pair User Command
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noAction(1), manualSwitchToWorkingPort(2), manualSwitchToProtectionPort(3), forcedSwitchToWorkingPort(4), forcedSwitchToProtectionPort(5), lockoutProtection(6), clear(7)  

oc3APSPairCurrentState 3.1.1751.2.18.2.16.1.1.14
Current State of the APS state machine
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER localprotectDoNotRevert(1), localprotectManualSw(8), localprotectSD(10), localprotectSF(12), localprotectForced(14), localprotectLockOut(15), localworkingDoNotRevert(17), localworkingManualSw(24), localworkingSD(26), localworkingSF(28), localworkingForced(30), remoteprotectDoNotRevert(33), remoteprotectManualSw(40), remoteprotectSD(42), remoteprotectSF(44), remoteprotectForced(46), remoteprotectLockOut(47), noRequest(48), remoteworkingDoNotRevert(49), remoteworkingManualSw(56), remoteworkingSD(58), remoteworkingSF(60), remoteworkingForced(62)  

oc3APSPairWorkingLineSignalStatus 3.1.1751.2.18.2.16.1.1.15
Signal Status of the working port (LOS / LOF / LCD / AIS etc.)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), signalDegradation(2), signalFailure(4), lostCellDelineation(8), switchByteFailure(16), ais-l(32), ais-p(64), lop(128), lof(256), los(512), moduleFailure(1024), lineLoopBack(2048), protocolFailure(4096), adminOutOfService(8192)  

oc3APSPairProtectionLineSignalStatus 3.1.1751.2.18.2.16.1.1.16
Signal Status of the protection port (LOS / LOF / LCD / AIS etc.)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), signalDegradation(2), signalFailure(4), lostCellDelineation(8), switchByteFailure(16), ais-l(32), ais-p(64), lop(128), lof(256), los(512), moduleFailure(1024), lineLoopBack(2048), protocolFailure(4096), adminOutOfService(8192)  

oc3APSPairStatsTable 3.1.1751.2.18.10.8
Table of statisics for a OC3 port
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Oc3APSPairStatsEntry

oc3APSPairStatsEntry 3.1.1751.2.18.10.8.1
Row definition for the OC3 port statistics table
Status: current Access: not-accessible
OBJECT-TYPE    
  Oc3APSPairStatsEntry  

oc3APSPairStatsId 3.1.1751.2.18.10.8.1.1
Working Port ID - Slot/Port (SSPP)
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

oc3APSPairWorkingSFDuration 3.1.1751.2.18.10.8.1.2
Duration in seconds for which the Work port has been in Signal Failure state
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

oc3APSPairWorkingSDDuration 3.1.1751.2.18.10.8.1.3
Duration in seconds for which the Work port has been in Signal Degradation state
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

oc3APSPairProtectionSFDuration 3.1.1751.2.18.10.8.1.4
Duration in seconds for which the Prot port has been in Signal Failure state
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

oc3APSPairProtectionSDDuration 3.1.1751.2.18.10.8.1.5
Duration in seconds for which the Prot port has been in Signal Degradation state
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

oc3APSPairTransmitK1K2Bytes 3.1.1751.2.18.10.8.1.6
The k1 / k2 bytes being transmitted by the prot port to the remote port.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(2)  

oc3APSPairReceiveK1K2Bytes 3.1.1751.2.18.10.8.1.7
k1 / k2 bytes from the received SONET header on the protection port. k1 / k2 are used for the APS communication protocol.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(2)  

oc3APSPairSwitchOverCount 3.1.1751.2.18.10.8.1.8
Number of times the APS pair has switched over since last configuration.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

twoWireSourcePortConfigTable 3.1.1751.2.18.2.7
Table of common physical Port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TwoWireSourcePortConfigEntry

twoWireSourcePortConfigEntry 3.1.1751.2.18.2.7.1
Row definition for common physical port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  TwoWireSourcePortConfigEntry  

twoWireSourcePortId 3.1.1751.2.18.2.7.1.1
interface index - SSPP
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

twoWireSourceLoopDetection 3.1.1751.2.18.2.7.1.2
This field selects terminal equipment loop circuit detection mode.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER loopStart(1), groundStart(2)  

twoWireSourceDialMode 3.1.1751.2.18.2.7.1.3
This field configures twoWireSource card to support communication terminal equipment.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER dtmf(1), dialPulse(2)  

twoWireSourceLoopBackConfig 3.1.1751.2.18.2.7.1.4
Configuration of 2W Source LoopBack.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noLoopback(1), facilityLoopback(2)  

twoWireSourceLineStatus 3.1.1751.2.18.2.7.1.5
twoWireSource line status: 1: NoAlarm: No alarm present 2: SignalingFailureState 4: FacilityLoopBack 8: Maintenance 16: Out Of Service 32: OtherFailure
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..1023  

twoWireSourceSignalingBits 3.1.1751.2.18.2.7.1.6
This field selects the signaling bits as seen in DS1 signal, ab or abcd.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ab(1), abcd(2)  

twoWireSourceRingCadence 3.1.1751.2.18.2.7.1.7
This field selects ring On/Off pattern.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER oneOnThreeOff(1)  

twoWireSourceSignalingState 3.1.1751.2.18.2.7.1.8
This field reflects the current signaling state.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER idle(1), dtmf(2), ringBack(3), connect(4), onHook(5), ringTrip(6), nearEndDisconnect(7), farEndDisconnect(8)  

twoWireSourceTestMode 3.1.1751.2.18.2.7.1.9
This field selects line test mode. For normal operation, this field should be OFF.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(1), quietTime(2), f-1004Hz(3)  

highSpeedPortConfigTable 3.1.1751.2.18.2.8
Table of common physical Port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HighSpeedPortConfigEntry

highSpeedPortConfigEntry 3.1.1751.2.18.2.8.1
Row definition for common physical port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  HighSpeedPortConfigEntry  

highSpeedPortId 3.1.1751.2.18.2.8.1.1
interface index - SSPP
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

highSpeedPortInputRate 3.1.1751.2.18.2.8.1.2
Port input rate
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

highSpeedPortOutputRate 3.1.1751.2.18.2.8.1.3
Port output rate
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

dspPortConfigTable 3.1.1751.2.18.2.9
Table of common physical Port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DspPortConfigEntry

dspPortConfigEntry 3.1.1751.2.18.2.9.1
Row definition for common physical port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  DspPortConfigEntry  

dspPortId 3.1.1751.2.18.2.9.1.1
interface index - SSPP
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

twoWireSinkPortConfigTable 3.1.1751.2.18.2.10
Table of common physical Port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TwoWireSinkPortConfigEntry

twoWireSinkPortConfigEntry 3.1.1751.2.18.2.10.1
Row definition for common physical port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  TwoWireSinkPortConfigEntry  

twoWireSinkPortId 3.1.1751.2.18.2.10.1.1
interface index - SSPP
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

twoWireSinkLoopDetection 3.1.1751.2.18.2.10.1.2
Types of loop detection.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER loopStart(1), groundStart(2)  

twoWireSinkDialMode 3.1.1751.2.18.2.10.1.3
This field selects subscribed dial mode.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER dtmf(1), dialPulse(2)  

twoWireSinkLineStatus 3.1.1751.2.18.2.10.1.4
twoWireSink line status: 1: NoAlarm: No alarm present 2: SignalingFailureState 4: FacilityLoopBack 8: Maintenance 16: Out Of Service 32: OtherFailure
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..1023  

twoWireSinkSignalingBits 3.1.1751.2.18.2.10.1.5
This field selects the signaling bits as seen in DS1 signal, ab or abcd.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ab(1), abcd(2)  

twoWireSinkSignalingState 3.1.1751.2.18.2.10.1.6
This field reflects the current signaling state.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER idle(1), connect(2), onHook(3), ringTrip(4), nearEndDisconnect(5), farEndDisconnect(6)  

twoWireSinkTestMode 3.1.1751.2.18.2.10.1.7
This field selects line test mode. For normal operation, this field should be OFF.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(1), quietTime(2), f-1004Hz(3)  

e3PortConfigTable 3.1.1751.2.18.2.11
Table of e3 specific port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    E3PortConfigEntry

e3PortConfigEntry 3.1.1751.2.18.2.11.1
Row definition for e3 specific port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  E3PortConfigEntry  

e3PortId 3.1.1751.2.18.2.11.1.1
slot/port: SSPP
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

e3LineType 3.1.1751.2.18.2.11.1.2
This variable indicates the basic frame structure supported in this E3 port. The rate of E3 is 34.368 Mbps. TITLE: SPECIFICATION: G.832 ITU-T G.832 1993. G.751 ITU-T G.751 1998
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER g832(1), g751(2)  

e3LineCoding 3.1.1751.2.18.2.11.1.3
The line code supported for the E3 port. The High Density Bipolar of order 3 (hdb3) as specified in section 8.1 of ITU-T G.703.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER hdb3(1)  

e3LoopbackConfig 3.1.1751.2.18.2.11.1.4
This variable represents the loopback configuration of the E3 interface. See above diagrams for explanations of loops.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noLoop(1), localLoop(2), lineLoop(3), payloadLoop(4)  

e3TransmitClockSource 3.1.1751.2.18.2.11.1.5
The source of Tranmit Clock. 'loopTiming' indicates that the recovered re- ceive clock is used as the transmit clock. 'localTiming' indicates that a local clock source is used. 'adaptiveTiming' indicates that the adaptive clocking mechanism is used.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER loopTiming(1), localTiming(2), adaptiveTiming(3)  

e3LineStatus 3.1.1751.2.18.2.11.1.6
e3 line status: 1: e3NoAlarm: No alarm present 2: e3RcvRAIFailure: Receiving Yellow/Remote Alarm Indication 4: e3XmitRAIAlarm: Transmitting Yellow/Remote Alarm Indication 8: e3RcvAIS: Receiving AIS failure state 16: e3XmitAIS: Transmitting AIS failure statue 32: e3LOF: Receiving LOF failure state 64: e3LOS: Reveiving LOS failure state 128: e3LoopbackState: Looping the received signal 256: e3RcvTestCode: Receiving a Test Pattern 512: e3OtherFailure: any line status not defined
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..1023  

e3LineBuildOut 3.1.1751.2.18.2.11.1.7
e3 line build out
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER short(1), long(2)  

e3LineScramble 3.1.1751.2.18.2.11.1.8
e3 line scramble
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

e3CellMapping 3.1.1751.2.18.2.11.1.9
e3 cell mapping method
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER directMapping(1), plcp(2)  

e1PortConfigTable 3.1.1751.2.18.2.12
Table of e1 specific port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    E1PortConfigEntry

e1PortConfigEntry 3.1.1751.2.18.2.12.1
Row definition for e1 specific port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  E1PortConfigEntry  

e1PortId 3.1.1751.2.18.2.12.1.1
interface index - slot/port: SSPP
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

e1Channelization 3.1.1751.2.18.2.12.1.2
e1 interface type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

e1LineType 3.1.1751.2.18.2.12.1.3
E1 interface type. The rate of E1 is 2.048 Mbps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER crc-mf(1)  

e1LineCoding 3.1.1751.2.18.2.12.1.4
e1 interface type
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER hdb3(1)  

e1LoopbackConfig 3.1.1751.2.18.2.12.1.5
This variable represents the loopback configuration of the e1 interface See above diagrams for explanations of loops.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noLoop(1), localLoop(2), lineLoop(3)  

e1TransmitClockSource 3.1.1751.2.18.2.12.1.6
e1 timing source
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER loopTiming(1), localTiming(2), adaptive(3)  

e1LineNationalBits 3.1.1751.2.18.2.12.1.7
e1 line country specific code
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER b00000(1), b00001(2), b00010(3), b00011(4), b00100(5), b00101(6), b00110(7), b00111(8), b01000(9), b01001(10), b01010(11), b01011(12), b01100(13), b01101(14), b01110(15), b01111(16), b10000(17), b10001(18), b10010(19), b10011(20), b10100(21), b10101(22), b10110(23), b10111(24), b11000(25), b11001(26), b11010(27), b11011(28), b11100(29), b11101(30), b11110(31), b11111(32)  

e1LineStatus 3.1.1751.2.18.2.12.1.8
This variable indicates the Line Status of the interface. It contains loopback, failure, re- ceived 'alarm' and transmitted 'alarm' infor- mation. The e1LineStatus is a bit map represented as a sum, therefore, it can represent multiple failures (alarms) and a LoopbackState simultaneously. e1NoAlarm should be set if and only if no other flag is set. If the e1LoopbackState bit is set, the loopback in effect can be determined from the e1LoopbackConfig object. The various bit positions are: 1: e1NoAlarm: No Alarm Present 2: e1RcvFarEndLOF: Far end LOF (a.k.a., Yellow Alarm) 4: e1XmtFarEndLOF: Near end sending LOF Indication 8: e1RcvAIS: Far end sending AIS 16: e1XmtAIS: Near end sending AIS 32: e1LossOfFrame: Near end LOF (a.k.a., Red Alarm) 64: e1LossOfSignal: Near end Loss Of Signal 128: e1LoopbackState: Near end is looped 256: e1T16AIS: E1 TS16 AIS 512: e1RcvFarEndLOMF: Far End Sending TS16 LOMF 1024: e1XmtFarEndLOMF: Near End Sending TS16 LOMF 2048: e1RcvTestCode: Near End detects a test code 4096: e1OtherFailure: any line status not defined here
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..8191  

e1TS16 3.1.1751.2.18.2.12.1.10
Time slot 16 is configurable for channel associated signaling (CAS) or data. cas: 'ABCD' signaling will be extracted in time slot 16 if channel is configured for circuit emulation. ccs: time slot 16 will not carry any e1 channel signaling information, instead, it will be used for data.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER cas(1), ccs(2)  

e1DataTransferType 3.1.1751.2.18.2.12.1.11
E1 data transfer type is only applicable in Circuit Emulation where unstructured CE packets entire T1 frame including the F-bit into the AAL1 for data tranfer, whereas, the structured CE packets the entire E1 frame except the Frame alignment signal channel.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER structured(1), unstructured(2)  

e1CRC4 3.1.1751.2.18.2.12.1.12
Enable or disable transmission of CRC4 bits on bit 1 of each frame.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

e1OamInterworkingType 3.1.1751.2.18.2.12.1.13
Specifies whether the interworking is done by trunk conditioning or unframed1s
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER trunkCond(1), unframed1s(2)  

e1EnhanceFeatureSet1 3.1.1751.2.18.2.12.1.14
To enable/disable a proprietary ab signaling scheme, it applies to all DS0s in the port. No individual DS0 signaling can be configured under the scheme.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

e1ConnGatewayFeature 3.1.1751.2.18.2.12.1.15
To enable/disable connection gateway (Sapphire) API.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

ethernetPortConfigTable 3.1.1751.2.18.2.13
Table of common physical Port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EthernetPortConfigEntry

ethernetPortConfigEntry 3.1.1751.2.18.2.13.1
Row definition for common physical port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  EthernetPortConfigEntry  

ethernetPortId 3.1.1751.2.18.2.13.1.1
interface index - SSPP
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

ethernetLinkType 3.1.1751.2.18.2.13.1.2
The type of port can either be set to 10baseT or 100baseT for the first port on the ethernet card. The other ports can only be set to 10baseT. The Auto mode will detect what LAN speed the port is connected to.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER l-10BaseT(1), l-100BaseT(2), auto(3)  

ethernetPhysicalAddr 3.1.1751.2.18.2.13.1.3
The MAC address used by this bridge when it must be referred to in a unique fashion. It is recommended that this be the numerically smallest MAC address of all ports that belong to this bridge. However it is only required to be unique. When concatenated with dot1dSprPriority a unique Bridgeidentifier is formed which is used in the Spanning Tree Protocol.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(6)  

ethernetLineStatus 3.1.1751.2.18.2.13.1.4
ethernet line status: 1: Down 2: 10baseT-FullDuplex 4: 10baseT-HalfDuplex 8: 100baseT-FullDuplex 16: 100baseT-HalfDuplex
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..31  

ethernetDuplexMode 3.1.1751.2.18.2.13.1.5
Set the port to either be in full or half duplex. You can also set the port to auto detect the mode it is connected to.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER full(1), half(2), auto(3)  

dsp2PortConfigTable 3.1.1751.2.18.2.14
Table of common physical Port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Dsp2PortConfigEntry

dsp2PortConfigEntry 3.1.1751.2.18.2.14.1
Row definition for common physical port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  Dsp2PortConfigEntry  

dsp2PortId 3.1.1751.2.18.2.14.1.1
interface index - SSPP
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

imaPortConfigTable 3.1.1751.2.18.2.15
Table used for the IMA virtual port on cards that have physical interfaces configured as atmIma. Corresponds to port 7 on DS1 and E1.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ImaPortConfigEntry

imaPortConfigEntry 3.1.1751.2.18.2.15.1
Row definition for ima specific port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  ImaPortConfigEntry  

imaPortId 3.1.1751.2.18.2.15.1.1
interface index - slot/port: SSPP
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sts1PortConfigTable 3.1.1751.2.18.2.17
Table of sts-1 specific port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sts1PortConfigEntry

sts1PortConfigEntry 3.1.1751.2.18.2.17.1
Row definition for sts-1 specific port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  Sts1PortConfigEntry  

sts1PortId 3.1.1751.2.18.2.17.1.1
slot/port: SSPP
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

sts1LineCoding 3.1.1751.2.18.2.17.1.2
This variable describes the variety of Zero Code Suppression used on this interface, which in turn affects a number of its characteristics. B3ZS refers to the use of specified patterns of normal bits and bipolar violations which are used to replace sequences of zero bits of a specified length.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER b3zs(1)  

sts1LoopbackConfig 3.1.1751.2.18.2.17.1.3
This variable represents the loopback configuration of the sts-1 interface. See above diagrams for explanations of loops.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noLoop(1), localLoop(2), lineLoop(3), payloadLoop(4)  

sts1TransmitClockSource 3.1.1751.2.18.2.17.1.4
The source of Tranmit Clock. 'loopTiming' indicates that the recovered re- ceive clock is used as the transmit clock. 'localTiming' indicates that a local clock source is used. 'cardFreeRun' indicates that a local oscillator on the I/O card is used as the transmit clock.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER loopTiming(1), localTiming(2), cardFreeRun(3)  

sts1LineBuildOut 3.1.1751.2.18.2.17.1.5
sts-1 line build out
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER short(1), long(2)  

sts1LineStatus 3.1.1751.2.18.2.17.1.6
sts-1 line status: 1: dsx3NoAlarm: No alarm present 2: dsx3RcvRAIFailure: Receiving Yellow/Remote Alarm Indication 4: dsx3XmitRAIAlarm: Transmitting Yellow/Remote Alarm Indication 8: dsx3RcvAIS: Receiving AIS failure state 16: dsx3XmitAIS: Transmitting AIS failure statue 32: dsx3LOF: Receiving LOF failure state 64: dsx3LOS: Reveiving LOS failure state 128: dsx3LoopbackState: Looping the received signal 256: dsx3RcvTestCode: Receiving a Test Pattern 512: dsx3OtherFailure: any line status not defined 1024: dsx3RcvRmtAIS: 2048: dsx3RcvRmtOOF: 4096: dsx3RcvRmtLOS: 8192: dsx3RcvRmtIdle: 16384: dsx3RmtLoopback: Far end remote loopback
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..32767  

sts1StsPointers 3.1.1751.2.18.2.17.1.7
status of the sts-1 sts pointers
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER locked(1), floating(2)  

sts1VtPointers 3.1.1751.2.18.2.17.1.8
status of the sts-1 vt pointers
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER locked(1), floating(2)  

tasmPortConfigTable 3.1.1751.2.18.2.18
Table of common physical Port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TasmPortConfigEntry

tasmPortConfigEntry 3.1.1751.2.18.2.18.1
Row definition for common physical port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  TasmPortConfigEntry  

tasmPortId 3.1.1751.2.18.2.18.1.1
interface index - SSPP
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

protectionGroupConfigTable 3.1.1751.2.18.2.19
This table gives the list of Slot Protection Groups in the System. Slot protection group in one in which there are n cards being protected by 1 standby card.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ProtectionGroupConfigEntry

protectionGroupConfigEntry 3.1.1751.2.18.2.19.1
Row Definition for the Protection Group Tables
Status: current Access: not-accessible
OBJECT-TYPE    
  ProtectionGroupConfigEntry  

protectionSlotId 3.1.1751.2.18.2.19.1.1
Protection Group Index. Index is the slot id of the Slot Configured as Protection.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..15  

workingSlotBitmap 3.1.1751.2.18.2.19.1.2
Working Slot Bitmap which the protection slot will monitor
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

protectionCommand 3.1.1751.2.18.2.19.1.3
List of commands which can be executed on a protection Group. Clear : This command is used to clear any previous commands which may have been and get back to normal nto1 operation Forced SwitchOver To Protection : Switchover to Protection card even if the working card is in service active These commands to used in conjunction with the working slot id.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER clear(1), forcedSwitchOverToProtection(2)  

protectionCommandSlotId 3.1.1751.2.18.2.19.1.4
This is the working Slot to which command has to be applied
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..15  

protectionGroupStatus 3.1.1751.2.18.2.19.1.5
Protection Status of a Protection Card. Inservice and OutofService indicates if the card has failed or still operational. Active or Standby state indicates if it is carrying active traffic or not.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), inservice-Active(2), inservice-Standby(3), outOfService-Active(4), outOfService-Standby(5)  

workingSlotId 3.1.1751.2.18.2.19.1.6
If protection group status is active, this field will give the slot which is being working. In case it is in standby mode this field will show 0
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..15  

workingFailedBitmap 3.1.1751.2.18.2.19.1.7
Gives Bitmap of the Failed Working Slots. Subset of the Working Slot Bitmap.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

protectionActiveCounter 3.1.1751.2.18.2.19.1.8
Give the Number of Times a Protection has gone to active.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

protectionOOSCounter 3.1.1751.2.18.2.19.1.9
Give the Number of Times a Protection Card has failed.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

taxiChannelConfigTable 3.1.1751.2.18.3.1
Table of common physical Port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TaxiChannelConfigEntry

taxiChannelConfigEntry 3.1.1751.2.18.3.1.1
Row definition for common physical port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  TaxiChannelConfigEntry  

taxiChannelId 3.1.1751.2.18.3.1.1.1
interface index - SSPPCC
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

taxiChannelIfType 3.1.1751.2.18.3.1.1.2
UNI or NNI type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unconfigured(1), atmUni3-0(2), atmUni3-1(3), iispUser(4), iispNetwork(5), atmUni4-0(6)  

taxiChannelSecuFeature 3.1.1751.2.18.3.1.1.3
enhancement feature
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unsecurable(1), secured(2), securable(3)  

ds3ChannelConfigTable 3.1.1751.2.18.3.2
Table of common physical channel attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ds3ChannelConfigEntry

ds3ChannelConfigEntry 3.1.1751.2.18.3.2.1
Row definition for common physical channel attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  Ds3ChannelConfigEntry  

ds3ChannelId 3.1.1751.2.18.3.2.1.1
interface index - SSPPCCC
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

ds3ChannelIfType 3.1.1751.2.18.3.2.1.2
UNI or NNI type,
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unconfigured(1), atmUni3-0(2), atmUni3-1(3), iispUser(4), iispNetwork(5), frameRelayUni(6), frameRelayNni(7), atmPnni1-0(8), atmUni4-0(9), circuitEmulation(10)  

ds3ChannelSecuFeature 3.1.1751.2.18.3.2.1.3
Interface type configured on DS3 channel
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unsecurable(1), secured(2), securable(3)  

ds1ChannelConfigTable 3.1.1751.2.18.3.3
Table of common physical Port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ds1ChannelConfigEntry

ds1ChannelConfigEntry 3.1.1751.2.18.3.3.1
Row definition for common physical port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  Ds1ChannelConfigEntry  

ds1ChannelId 3.1.1751.2.18.3.3.1.1
interface index - SSPPCCC
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

ds1ChannelIfType 3.1.1751.2.18.3.3.1.2
UNI or NNI type for ATM ,Frame Relay, or ISDN service interface type for channel
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unconfigured(1), atmUni3-0(2), atmUni3-1(3), iispUser(4), iispNetwork(5), circuitEmulation(6), frameRelayUni(7), hdlcPassThrough(8), pri-isdn-network(9), dbCirEm(10), frameRelayNni(11), pri-isdn-user(12), atmIma(13), atmPnni1-0(14), casTrunkLine(15), atmUni4-0(16), gr303(17)  

ds1ChannelDs0Map 3.1.1751.2.18.3.3.1.3
bit map of DS0 in channel
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(3)  

ds1ChannelCellMapping 3.1.1751.2.18.3.3.1.4
cell delineation mode for ATM cell bearing services
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER directMapping(1), none(2)  

ds1ChannelInputCodingRule 3.1.1751.2.18.3.3.1.5
enhancement feature
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), muLawPCM(2), aLawPCM(3), digital(4)  

ds1ChannelSecuFeature 3.1.1751.2.18.3.3.1.6
enhancement feature
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unsecurable(1), secured(2), securable(3)  

ds1ChannelSignaling 3.1.1751.2.18.3.3.1.7
refers to robbed-bit signaling in circuitEmulation interfaces.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

ds1ChannelCellScramble 3.1.1751.2.18.3.3.1.8
refers to enabling/disabling cell scrambling on ATM interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

msChannelConfigTable 3.1.1751.2.18.3.4
Channel configuration table for multi-serial ports.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MsChannelConfigEntry

msChannelConfigEntry 3.1.1751.2.18.3.4.1
Row definition for multi-serial channel config.
Status: current Access: not-accessible
OBJECT-TYPE    
  MsChannelConfigEntry  

msChannelId 3.1.1751.2.18.3.4.1.1
interface index - SSPPCCC
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

msChannelIfType 3.1.1751.2.18.3.4.1.2
interface type for multi-serial port
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unconfigured(1), atmUni3-0(2), atmUni3-1(3), iispUser(4), iispNetwork(5), circuitEmulation(6), terminalEmulation(7), frameRelayUni(8), hdlcPassThrough(9), frameRelayNni(10), atmPnni1-0(11), atmUni4-0(12)  

msChannelCellBearingMode 3.1.1751.2.18.3.4.1.3
The cell delineation mode is either LANET or CCITT based
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER lanet(1), ccittDirectMapping(2), none(3)  

msChannelCellBearingAddrMode 3.1.1751.2.18.3.4.1.4
standard - ATM Forum UNI 3.0/3.1 noiseTolerant - A proprietary noise tolerant address mapping scheme
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER standard(1), noiseTolerant(2)  

msChannelCellBearingPayloadFec 3.1.1751.2.18.3.4.1.5
payload error correction scheme
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER dynamic(1), threeEighthsRate(2), oneQuarterRate(3), oneEighthRate(4)  

msChannelSecuFeature 3.1.1751.2.18.3.4.1.6
enhancement feature
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unsecurable(1), secured(2), securable(3)  

oc3ChannelConfigTable 3.1.1751.2.18.3.5
Table of common physical Port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Oc3ChannelConfigEntry

oc3ChannelConfigEntry 3.1.1751.2.18.3.5.1
Row definition for common physical port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  Oc3ChannelConfigEntry  

oc3ChannelId 3.1.1751.2.18.3.5.1.1
interface index - SSPPCC
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

oc3ChannelIfType 3.1.1751.2.18.3.5.1.2
UNI or NNI type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unconfigured(1), atmUni3-0(2), atmUni3-1(3), iispUser(4), iispNetwork(5), atmPnni1-0(6), atmUni4-0(7), atmVnnUni3-1(8)  

oc3ChannelSecuFeature 3.1.1751.2.18.3.5.1.3
enhancement feature
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unsecurable(1), secured(2), securable(3)  

twoWireSourceChannelConfigTable 3.1.1751.2.18.3.6
Table of common physical Port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TwoWireSourceChannelConfigEntry

twoWireSourceChannelConfigEntry 3.1.1751.2.18.3.6.1
Row definition for common physical port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  TwoWireSourceChannelConfigEntry  

twoWireSourceChannelId 3.1.1751.2.18.3.6.1.1
interface index - SSPPCC
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

twoWireSourceChannelIfType 3.1.1751.2.18.3.6.1.2
Interface types of 2W station(source) channel.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unconfigured(1), circuitEmulation(2)  

twoWireSourceChannelConnectionType 3.1.1751.2.18.3.6.1.3
This field selects ATM virtual circuit connection type, PVC or SVC.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER pvc(1), svc(2)  

twoWireSourceChannelCompandingLaw 3.1.1751.2.18.3.6.1.4
This field selects channel encoding/decoding quantization interval, muLaw or aLaw.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER muLawPCM(1), aLawPCM(2)  

twoWireSourceChannelSecuFeature 3.1.1751.2.18.3.6.1.5
enhancement feature
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unsecurable(1), secured(2), securable(3)  

twoWireSourceChannelVoiceCompression 3.1.1751.2.18.3.6.1.6
voice compression scheme
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), adpcm32k(2), adpcm16k(3), adpcm8k(4)  

twoWireSourceChannelEchoCancellation 3.1.1751.2.18.3.6.1.7
This field disables/enables twoWireSource card echo cancellation function.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

twoWireSourceChannelSilenceSupression 3.1.1751.2.18.3.6.1.8
This field disables/enables twoWireSource card silence suppression.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

twoWireSourceChannelEncapsulationAal 3.1.1751.2.18.3.6.1.9
This field selects ATM cell payload format. Aal1 - ATM Adaption Layer Type 1. Yurie - A proprietary specific ATM cell payload format for compressed data.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER aal1(1), lucent(2)  

twoWireSourceChannelSubscriberService 3.1.1751.2.18.3.6.1.10
This field selects subscribed channel service types. plar - Private Line Automatic Ring fxs - Foreign Exchange Subscriber End s-signaling - A proprietary specific signaling type based on AIN model.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER plar(1), fxs(2), s-signaling(3)  

highSpeedChannelConfigTable 3.1.1751.2.18.3.7
Table of common physical Port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HighSpeedChannelConfigEntry

highSpeedChannelConfigEntry 3.1.1751.2.18.3.7.1
Row definition for common physical port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  HighSpeedChannelConfigEntry  

highSpeedChannelId 3.1.1751.2.18.3.7.1.1
interface index - SSPPCC
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

highSpeedChannelIfType 3.1.1751.2.18.3.7.1.2
UNI or NNI type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unconfigured(1), atmUni3-0(2), atmUni3-1(3), iispUser(4), iispNetwork(5), circuitEmulation(6), atmUni4-0(7)  

dspChannelConfigTable 3.1.1751.2.18.3.8
Table of common physical Port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DspChannelConfigEntry

dspChannelConfigEntry 3.1.1751.2.18.3.8.1
Row definition for common physical port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  DspChannelConfigEntry  

dspChannelId 3.1.1751.2.18.3.8.1.1
interface index - SSPPCC
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

dspChannelIfType 3.1.1751.2.18.3.8.1.2
Channel Interface Type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unconfigured(1), dsp(2)  

dspChannelInputCodingRule 3.1.1751.2.18.3.8.1.3
Input Coding Rule
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER muLawPCM(1)  

dspChannelVoiceCompression 3.1.1751.2.18.3.8.1.4
voice compression scheme
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER adpcm32k(1), adpcm16k(2)  

dspChannelEchoCancellation 3.1.1751.2.18.3.8.1.5
voice compression scheme
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1)  

dspChannelSilenceSupression 3.1.1751.2.18.3.8.1.6
voice compression scheme
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1)  

twoWireSinkChannelConfigTable 3.1.1751.2.18.3.9
Table of common physical Port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TwoWireSinkChannelConfigEntry

twoWireSinkChannelConfigEntry 3.1.1751.2.18.3.9.1
Row definition for common physical port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  TwoWireSinkChannelConfigEntry  

twoWireSinkChannelId 3.1.1751.2.18.3.9.1.1
interface index - SSPPCC
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

twoWireSinkChannelIfType 3.1.1751.2.18.3.9.1.2
Interface types.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unconfigured(1), circuitEmulation(2)  

twoWireSinkChannelConnectionType 3.1.1751.2.18.3.9.1.3
This field selects ATM virtual circuit connection type, PVC or SVC.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER pvc(1), svc(2)  

twoWireSinkChannelCompandingLaw 3.1.1751.2.18.3.9.1.4
This field selects channel encoding/decoding quantization interval, muLaw or aLaw.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER muLawPCM(1), aLawPCM(2)  

twoWireSinkChannelVoiceCompression 3.1.1751.2.18.3.9.1.5
voice compression scheme
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), adpcm32k(2), adpcm16k(3), adpcm8k(4)  

twoWireSinkChannelEchoCancellation 3.1.1751.2.18.3.9.1.6
This field disables/enables twoWireSink card echo cancellation function.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

twoWireSinkChannelSilenceSupression 3.1.1751.2.18.3.9.1.7
This field disables/enables twoWireSink card silence suppression.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

twoWireSinkChannelEncapsulationAal 3.1.1751.2.18.3.9.1.8
This field selects ATM cell payload format. Aal1 - ATM Adaption Layer Type 1. Yurie - A proprietary specific ATM cell payload format for compressed data.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER aal1(1), lucent(2)  

twoWireSinkChannelSubscriberService 3.1.1751.2.18.3.9.1.9
The only available service type for twoWireSink card is Foreign Exchange Office End (fxo).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER fxo(1)  

e3ChannelConfigTable 3.1.1751.2.18.3.10
Table of common physical channel attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    E3ChannelConfigEntry

e3ChannelConfigEntry 3.1.1751.2.18.3.10.1
Row definition for common physical channel attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  E3ChannelConfigEntry  

e3ChannelId 3.1.1751.2.18.3.10.1.1
interface index - SSPPCCC
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

e3ChannelIfType 3.1.1751.2.18.3.10.1.2
Interface type configured on E3 channel
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unconfigured(1), atmUni3-0(2), atmUni3-1(3), iispUser(4), iispNetwork(5), atmPnni1-0(6), atmUni4-0(7), circuitEmulation(8)  

e3ChannelSecuFeature 3.1.1751.2.18.3.10.1.3
enhancement feature
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unsecurable(1), secured(2), securable(3)  

e1ChannelConfigTable 3.1.1751.2.18.3.11
Table of common physical Port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    E1ChannelConfigEntry

e1ChannelConfigEntry 3.1.1751.2.18.3.11.1
Row definition for common physical port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  E1ChannelConfigEntry  

e1ChannelId 3.1.1751.2.18.3.11.1.1
interface index - SSPPCCC
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

e1ChannelIfType 3.1.1751.2.18.3.11.1.2
UNI or NNI type for ATM ,Frame Relay, or ISDN serviceinterface type for channel
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unconfigured(1), atmUni3-0(2), atmUni3-1(3), iispUser(4), iispNetwork(5), circuitEmulation(6), frameRelayUni(7), hdlcPassThrough(8), frameRelayNni(9), atmIma(10), atmPnni1-0(11), pri-isdn-network(12), pri-isdn-user(13), casTrunkLine(14), atmUni4-0(15)  

e1ChannelDs0Map 3.1.1751.2.18.3.11.1.3
bit map of DS0 in channel
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

e1ChannelCellMapping 3.1.1751.2.18.3.11.1.4
cell delineation mode for ATM cell bearing services
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER directMapping(1), none(2)  

e1ChannelInputCodingRule 3.1.1751.2.18.3.11.1.5
enhancement feature
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), muLawPCM(2), aLawPCM(3), digital(4)  

e1ChannelSecuFeature 3.1.1751.2.18.3.11.1.6
enhancement feature
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unsecurable(1), secured(2), securable(3)  

e1ChannelSignaling 3.1.1751.2.18.3.11.1.7
Refers to robbed-bit singaling in circuitEmulation interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

ethernetChannelConfigTable 3.1.1751.2.18.3.12
Table used for enthernet channel configuration.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EthernetChannelConfigEntry

ethernetChannelConfigEntry 3.1.1751.2.18.3.12.1
Row definition for enthernet channel attributes.
Status: current Access: not-accessible
OBJECT-TYPE    
  EthernetChannelConfigEntry  

ethernetChannelId 3.1.1751.2.18.3.12.1.1
Interface index
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

ethernetChannelIfType 3.1.1751.2.18.3.12.1.2
Types of ethernet interface. There are two types of bridging interface(channel):bridge and routing.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unconfigured(1), bridge(2), routing(3)  

dsp2Channel 3.1.1751.2.18.3.13
OBJECT IDENTIFIER    

dsp2ChannelConfigTable 3.1.1751.2.18.3.13.1
Table of Channel attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Dsp2ChannelConfigEntry

dsp2ChannelConfigEntry 3.1.1751.2.18.3.13.1.1
Row definition for common physical port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  Dsp2ChannelConfigEntry  

dsp2ChannelId 3.1.1751.2.18.3.13.1.1.1
interface index - SSPPCC
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

dsp2ChannelIfType 3.1.1751.2.18.3.13.1.1.2
Channel Interface Type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unconfigured(1), dsp2(2)  

dsp2ChannelAlarmType 3.1.1751.2.18.3.13.1.1.3
This field is a read only failure which gives the status of a dsp.When the status is dspFailure the Operational Status at the interface level will go OOS
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), dspFailure(2)  

dsp2ChannelModeConfig 3.1.1751.2.18.3.13.1.1.4
This field is used to configure the mode of the DSP card. Each mode corresponds to a set of algorithms supported by the IO card. The complete list of enumerations of supported algorithms is given in the dsp2AlgorithmTable. The following description outlines the algorithms supported in each corresponding AlgoSet. algoSet1 : g168-echo-cancellation128ms algoSet2 : g726-voice-compression, g165-echo-cancellation, generic-silence-suppression, fax-modem-tone-detection, g168-echo-cancellation64ms. algoSet3 : g729a-voice-compression, g165-echo-cancellation, g729b-silence-suppression, fax-modem-tone-detection, g168-echo-cancellation64ms. algoSet4 : v17-fax-algorithm-upto-14400-bps, v29-fax-algorithm-upto-9600-bps, v27ter-fax-algorithm-upto-2400-bps, v21-fax-algorithm-upto-300-bps. algoSet5 : g168-echo-cancellation64ms. algoSet6 : g726-voice-compression, g729a-voice-compression, g729b-silence-suppression, g168-echo-cancellation64ms, v17-fax-algorithm-upto-14400-bps, v29-fax-algorithm-upto-9600-bps, v27ter-fax-algorithm-upto-2400-bps, v21-fax-algorithm-upto-300-bps.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER algoSet1(1), algoSet2(2), algoSet3(3), algoSet4(4), algoSet5(5), algoSet6(6)  

dsp2AlgorithmTable 3.1.1751.2.18.3.13.2
Table of dsp2 algorithms assigned to interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Dsp2AlgorithmEntry

dsp2AlgorithmEntry 3.1.1751.2.18.3.13.2.1
Row definition for dsp2 algorithms assigned to interfaces.
Status: current Access: not-accessible
OBJECT-TYPE    
  Dsp2AlgorithmEntry  

dsp2AlgorithmId 3.1.1751.2.18.3.13.2.1.1
interface index - SSPPCC
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

dsp2AlgorithmType 3.1.1751.2.18.3.13.2.1.2
DSP Algorithm type.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER g726-voice-compression(1), g165-echo-cancellation(2), generic-silence-suppression(3), fax-modem-tone-detection(4), g729a-voice-compression(5), g729b-silence-suppression(6), g168-echo-cancellation64ms(7), g168-echo-cancellation128ms(8), v17-fax-algorithm-upto-14400-bps(9), v29-fax-algorithm-upto-9600-bps(10), v27ter-fax-algorithm-upto-2400-bps(11), v21-fax-algorithm-upto-300-bps(12)  

imaGrpChannelConfigTable 3.1.1751.2.18.3.14
Table used for the IMA virtual channel (group) configuration on cards that have physical interfaces configured as atmIma. Represents three channels that can be configured as IMA groups on port 7 of DS1 and E1 cards.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ImaGrpChannelConfigEntry

imaGrpChannelConfigEntry 3.1.1751.2.18.3.14.1
Row definition for common physical port attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  ImaGrpChannelConfigEntry  

imaGrpChannelId 3.1.1751.2.18.3.14.1.1
interface index - SSPPCCC
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

imaGrpChannelIfType 3.1.1751.2.18.3.14.1.2
interface type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unconfigured(1), atmUni3-0(2), atmUni3-1(3), iispUser(4), iispNetwork(5), atmPnni1-0(6), atmUni4-0(7)  

imaGrpChannelPortMap 3.1.1751.2.18.3.14.1.3
A bitmap that identifies the physical IMA interfaces in this group. The least significant bit represents port 1.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

imaGrpChannelNeState 3.1.1751.2.18.3.14.1.4
The current operational state of the near-end IMA Group State Machine.
Status: current Access: read-only
OBJECT-TYPE    
  ImaGrpChannelEndState  

imaGrpChannelFeState 3.1.1751.2.18.3.14.1.5
The current operational state of the far-end IMA Group State Machine.
Status: current Access: read-only
OBJECT-TYPE    
  ImaGrpChannelEndState  

imaGrpChannelFailureStatus 3.1.1751.2.18.3.14.1.6
The current failure status of the IMA group (the reason why the GTSM is in the down state). noFailure(1) no failure startUpNe(2) near-end is in the state of start-up startUpFe(3) far-end is in the state of start-up invalidMValueNe(4) near-end has invalid frame length invalidMValueFe(5) far-end has invalid frame length failedAssymetricNe(6) near-end failed due to incompatable symmetry failedAssymetricFe(7) far-end failed due to incompatable symmetry insuffLinksNe(8) Near-end reported less than the min number of Tx links are active or less than the min number of Rx links are active insuffLinksFe(9) Far-end reported less than the min number of Rx links are active or less than thenmin number of Tx links are active blockedNe(10) Near-end is administratively out-of-service blockedFe(11) Far-end is administratively out-of-service otherFailure(12) other failures
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noFailure(1), startUpNe(2), startUpFe(3), invalidMValueNe(4), invalidMValueFe(5), failedAssymetricNe(6), failedAssymetricFe(7), insuffLinksNe(8), insuffLinksFe(9), blockedNe(10), blockedFe(11), otherFailure(12)  

imaGrpChannelSymmetry 3.1.1751.2.18.3.14.1.7
Symmetry of the IMA group. Symmetric configuration: all ports of IMA group are configured as full-duplex. With symmetric configuration, operation is symmetric if no links failes; is asymmetric if a link fails so that the active forward and backward links between far-end and near-end are asymmetric. If the configuration is asymmetric, the operation can never be symmetric.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER symOperation(1), asymOperation(2), asymConfiguration(3)  



imaGrpChannelNeTxClkMode 3.1.1751.2.18.3.14.1.10
Transmit clocking mode used by the near-end IMA group. There are two possible modes: the Common Transmit Clock (CTC) and the Independent Transmit Clock (ITC). The CTC mode corresponds to the case when the transmit clock of all IMA links are derived from the same source. The ITC configuration corresponds to the case where there is at least one IMA link whose transmit clock is derived from a source different than at least another link transmit clock. The underlying clock configuration must be set up by the user to ensure operation in the selected mode.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ctc(1), itc(2)  

imaGrpChannelFeTxClkMode 3.1.1751.2.18.3.14.1.11
Transmit clocking mode used by the far-end IMA group. There are two possible modes: the Common Transmit Clock (CTC) and the Independent Transmit Clock (ITC). The CTC mode corresponds to the case when the transmit clock of all IMA links are derived from the same source. The ITC configuration corresponds to the case where there is at least one IMA link whose transmit clock is derived from a source different than at least another link transmit clock.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ctc(1), itc(2)  

imaGrpChannelTxImaId 3.1.1751.2.18.3.14.1.12
The IMA ID currently in use by the near-end IMA function.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

imaGrpChannelRxImaId 3.1.1751.2.18.3.14.1.13
The IMA ID currently in use by the far-end IMA function.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

imaGrpChannelTxFrameLength 3.1.1751.2.18.3.14.1.14
The frame length to be used by the IMA group in the transmit direction. Can only be set when the IMA group is startup.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER m32(32), m64(64), m128(128), m256(256)  

imaGrpChannelRxFrameLength 3.1.1751.2.18.3.14.1.15
Value of IMA frame length as received from remote IMA function.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER m32(32), m64(64), m128(128), m256(256)  

imaGrpChannelDiffLinkDelayMax 3.1.1751.2.18.3.14.1.16
The maximum number of milliseconds of delay differential among the links that will be tolerated on this interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..200  


imaGrpChannelDiffDelayMaxObs 3.1.1751.2.18.3.14.1.18
The latest maximum differential delay observed (in milliseconds), i.e. between the links having the least and most link propagation delay, among the receive links that are currently configured in the IMA group.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

imaGrpChannelAlphaValue 3.1.1751.2.18.3.14.1.19
This indicates the 'alpha' value used to specify the number of consecutive invalid ICP cells to be detected before moving to the IMA HUNT state.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..2  

imaGrpChannelBetaValue 3.1.1751.2.18.3.14.1.20
This indicates the 'beta' value used to specify the number of consecutive errored ICP cells to be detected before moving to the IMA HUNT state.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..5  

imaGrpChannelGammaValue 3.1.1751.2.18.3.14.1.21
This indicates the 'gamma' value used to specify the number of consecutive valid ICP cells to be detected before moving to the IMA SYNC state from the PRESYNC state.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..5  

imaGrpChannelStatsNeNumFailures 3.1.1751.2.18.3.14.1.22
The number of times a near-end group failure (Config-Abort, Insufficient-Links) has been reported.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

imaGrpChannelStatsFeNumFailures 3.1.1751.2.18.3.14.1.23
The number of times a far-end group failure (Config-Abort-FE, Insufficient-Links-FE, Blocked-FE) has been reported.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

imaGrpChannelStatsNumTxActLnks 3.1.1751.2.18.3.14.1.24
The number of links which are configured to transmit and are currently Active in this IMA group.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

imaGrpChannelStatsNumRxActLnks 3.1.1751.2.18.3.14.1.25
The number of links which are configured to receive and are currently Active in this IMA group.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

imaGrpChannelStatsTimer 3.1.1751.2.18.3.14.1.26
Time, in seconds, since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

imaGrpChannelCompatMode 3.1.1751.2.18.3.14.1.27
This is used to indicate interoperability mode to the I/O card in terms of reporting the link status at the correct location in the IMA Control Protocol (ICP) cell
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

tasmChannelConfigTable 3.1.1751.2.18.3.15
Table of common physical Channel attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TasmChannelConfigEntry

tasmChannelConfigEntry 3.1.1751.2.18.3.15.1
Row definition for common physical channel attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  TasmChannelConfigEntry  

tasmChannelId 3.1.1751.2.18.3.15.1.1
Interface index - SSPPCC
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

tasmChannelIfType 3.1.1751.2.18.3.15.1.2
Channel Interface Type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unconfigured(1), toneAnnce(2)  

tasmChannelAlarmType 3.1.1751.2.18.3.15.1.3
This field is a read only failure which gives the status of a DSP in the TASM card.When the status is tasmFailure the Operational Status at the interface level will go OOS
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), tasmFailure(2)  

tasmChannelModeConfig 3.1.1751.2.18.3.15.1.4
This field is used to configure the mdoe in which a TASM DSP will be used asd a resource. The modes are explained as follows: casMode: DSP resource is used for DTMF/MF tone detection/generation and running the Type 100, 105, and 108 tests. tasMode: DSP resource is used for playing/compressing announcement.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER casMode(1), tasMode(2)  

atmUniConfigTable 3.1.1751.2.18.5.1
Table of atm user to network interface (UNI)
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmUniConfigEntry

atmUniConfigEntry 3.1.1751.2.18.5.1.1
Row definition of atm UNI
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmUniConfigEntry  

atmUniIfIndex 3.1.1751.2.18.5.1.1.1
interface index (slot/port/channel) SSPPCCC
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

atmUniAddrType 3.1.1751.2.18.5.1.1.2
atm address type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER nsap(1), e164(2), private(3)  

atmUniSvcMinVpi 3.1.1751.2.18.5.1.1.3
The lower bound of the VPI for SVC connections.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

atmUniSvcMaxVpi 3.1.1751.2.18.5.1.1.4
The upper bound of the VPI for SVC connections.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

atmUniSvcMinVci 3.1.1751.2.18.5.1.1.5
The lower bound of the VCI for SVC connections.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

atmUniSvcMaxVci 3.1.1751.2.18.5.1.1.6
The upper bound of the VCI for SVC connections.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

atmUniAdminStatus 3.1.1751.2.18.5.1.1.7
The administrative action: 'outOfService' means take the UNI out of service 'inService' means take the UNI in service 'delete' remove/deconfigure the UNI.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2), delete(3)  

atmUniOperStatus 3.1.1751.2.18.5.1.1.8
The operational status of the UNI: 'outOfService' means the UNI is out of service 'inService' means the UNI is in service
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2)  

atmUniNwPrefix1 3.1.1751.2.18.5.1.1.9
ATM Network Prefix 1
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(13)  

atmUniOverSubscription 3.1.1751.2.18.5.1.1.10
Over subscription factor
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..100  

atmUniT303 3.1.1751.2.18.5.1.1.11
Timer T303 value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmUniT308 3.1.1751.2.18.5.1.1.12
Timer T308 value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmUniT309 3.1.1751.2.18.5.1.1.13
Timer T309 value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmUniT310 3.1.1751.2.18.5.1.1.14
Timer T310 value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmUniT313 3.1.1751.2.18.5.1.1.15
Timer T313 value - User side only - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmUniT316 3.1.1751.2.18.5.1.1.16
Timer T316 value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmUniT317 3.1.1751.2.18.5.1.1.17
Timer T317 value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmUniT322 3.1.1751.2.18.5.1.1.18
Timer T322 value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmUniT398 3.1.1751.2.18.5.1.1.19
Timer T398 value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmUniT399 3.1.1751.2.18.5.1.1.20
Timer T399 value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmUniMyNeighborIpAddress 3.1.1751.2.18.5.1.1.21
The IP address of the neighbor system connected to the far end of this interface, to which a Network Management Station can send SNMP messages, as IP datagrams sent to UDP port 161, in order to access network management information concerning the operation of that system. Note that the value of this object can currently only be obtained by manual configuration.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

atmUniMyNeighborIfName 3.1.1751.2.18.5.1.1.22
The textual name of the interface on the neighbor system on the far end of this interface, and to which this interface connects. If the neighbor system is manageable through SNMP and supports the object ifName, the value of this object must be identical with that of ifName for the ifEntry of the lowest level physical interface for this port. If this interface does not have a textual name, the value of this object is a zero length string. Note that the value of this object can currently only be obtained by manual configuration.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(20)  

atmUniVpiSig 3.1.1751.2.18.5.1.1.23
VPI value for the signalling channel for the UNI interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

atmUniVciSig 3.1.1751.2.18.5.1.1.24
VCI value for the signalling channel for the UNI interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..31  

atmUniVpiIlmi 3.1.1751.2.18.5.1.1.25
VPI value for the ilmi channel for the UNI interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

atmUniVciIlmi 3.1.1751.2.18.5.1.1.26
VCI value for the ilmi channel for the UNI interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..31  

atmUniAtmSignalingStatus 3.1.1751.2.18.5.1.1.27
Indicates if atm signaling is enabled or disabled for this interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

atmUniMyIfName 3.1.1751.2.18.5.1.1.29
A textual name of this interface. If this system is manageable manageable through SNMP and supports the object ifName, the value of this object must be identical with that of ifName for the ifEntry of the lowest level physical interface for this port. This interface must be uniquely named on this system to distinguish parallel links with a neighboring system. If this interface does not have a textual name, the value of this object is a zero length string.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(20)  

atmUniIlmiProtocolStatus 3.1.1751.2.18.5.1.1.30
The administrative status: 'enabled' - ILMI protocol enabled on UNI 'disabled' - ILMI protocol disabled on UNI.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

atmUniIlmiOperStatus 3.1.1751.2.18.5.1.1.31
The operational status: 'outOfService' - ILMI connectivity is down 'inService' - ILMI connectivity is up.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2)  

atmUniIlmiConfigProc 3.1.1751.2.18.5.1.1.32
ILMI Configuration Procedure status.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

atmUniIlmiConnectProc 3.1.1751.2.18.5.1.1.33
ILMI Connectivity Procedure status.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

atmUniIlmiAttachPtProc 3.1.1751.2.18.5.1.1.34
ILMI Attachment Point Procedure status.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

atmUniIlmiSecureLinkProc 3.1.1751.2.18.5.1.1.35
ILMI Secure Link Procedure status. Can be enabled only if Attachment Point Procedure is enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

atmUniIlmiAddrRegProc 3.1.1751.2.18.5.1.1.36
ILMI Address Registration Procedure status.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

atmUniIlmiTimerS 3.1.1751.2.18.5.1.1.37
Timer S (secs). Used to poll peer when link is down.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmUniIlmiTimerT 3.1.1751.2.18.5.1.1.38
Timer T (secs). Used to poll peer when link is up.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmUniIlmiRetryK 3.1.1751.2.18.5.1.1.39
Retry K - number of timeouts before link is declared down.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmUniIntfType 3.1.1751.2.18.5.1.1.40
atm interface type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER user(1), network(2)  

atmUniUserAddress 3.1.1751.2.18.5.1.1.41
ATM User Address
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(7)  

atmUniViSuppFlag 3.1.1751.2.18.5.1.1.42
virtual interface supp off/on
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

atmUniUPCSupp 3.1.1751.2.18.5.1.1.43
upc supp off/on
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

atmUniUbrLoadBalSupp 3.1.1751.2.18.5.1.1.44
load balancing supp for ubr conns off/on
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

atmUniAvailBwIgr 3.1.1751.2.18.5.1.1.45
The Avail Bandwidth for that interface in cells per sec. Bandwidth for UBR conns will not be accounted for
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmUniAvailBwEgr 3.1.1751.2.18.5.1.1.46
The Avail Bandwidth for that interface in cells per sec which can go out of the interface. Bandwidth for UBR conns will not be accounted for
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmUniVUNISuppFlag 3.1.1751.2.18.5.1.1.47
virtual UNI interface supp off/on
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

atmUniUserAddrOrgScope 3.1.1751.2.18.5.1.1.48
ATM User Address Organizational scope
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER localNetwork(1), localNetworkPlusOne(2), localNetworkPlusTwo(3), siteMinusOne(4), intraSite(5), sitePlusOne(6), organizationMinusOne(7), intraOrganization(8), organizationPlusOne(9), communityMinusOne(10), intraCommunity(11), communityPlusOne(12), regional(13), interRegional(14), global(15)  

atmUniSscopRxWndSz 3.1.1751.2.18.5.1.1.49
The receive window size for the SSCOP layer
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 8..256  

atmUniConnTrafficShapingFlag 3.1.1751.2.18.5.1.1.50
Traffic Shaping for Conn was enabled primarily because the core would lose cells since we were non-conformant cells. Therefore the hardware added traffic shaping per connection. But condition is VI should not be enabled if this feature is enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

atmIispConfigTable 3.1.1751.2.18.5.2
Table of atm iisp interface
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmIispConfigEntry

atmIispConfigEntry 3.1.1751.2.18.5.2.1
Row definition of atm iisp interface
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmIispConfigEntry  

atmIispIfIndex 3.1.1751.2.18.5.2.1.1
interface index (slot/port/channel) SSPPCCC
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

atmIispSvcMinVpi 3.1.1751.2.18.5.2.1.2
The lower bound of the VPI for SVC connections.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

atmIispSvcMaxVpi 3.1.1751.2.18.5.2.1.3
The upper bound of the VPI for SVC connections.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

atmIispSvcMinVci 3.1.1751.2.18.5.2.1.4
The lower bound of the VCI for SVC connections.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

atmIispSvcMaxVci 3.1.1751.2.18.5.2.1.5
The upper bound of the VCI for SVC connections.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

atmIispAdminStatus 3.1.1751.2.18.5.2.1.6
The administrative action: 'outOfService' means take the UNI out of service 'inService' means take the UNI in service 'delete' remove/deconfigure the UNI.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2), delete(3)  

atmIispOperStatus 3.1.1751.2.18.5.2.1.7
The operational status of the UNI: 'outOfService' means the UNI is out of service 'inService' means the UNI is in service
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2)  

atmIispOverSubscription 3.1.1751.2.18.5.2.1.8
Over subscription factor
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..100  

atmIispT303 3.1.1751.2.18.5.2.1.9
Timer value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmIispT308 3.1.1751.2.18.5.2.1.10
Timer value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmIispT309 3.1.1751.2.18.5.2.1.11
Timer value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmIispT310 3.1.1751.2.18.5.2.1.12
Timer value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmIispT316 3.1.1751.2.18.5.2.1.13
Timer value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmIispT317 3.1.1751.2.18.5.2.1.14
Timer value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmIispT322 3.1.1751.2.18.5.2.1.15
Timer value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmIispT398 3.1.1751.2.18.5.2.1.16
Timer value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmIispT399 3.1.1751.2.18.5.2.1.17
Timer value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmIispAtmSignalingStatus 3.1.1751.2.18.5.2.1.18
Indicates if atm signaling is enabled or disabled for this interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

atmIispAvailBwIgr 3.1.1751.2.18.5.2.1.19
The Avail Bandwidth for that interface in cells per sec. Bandwidth for UBR conns will not be accounted for.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmIispAvailBwEgr 3.1.1751.2.18.5.2.1.20
The Avail Bandwidth for that interface in cells per sec. Bandwidth for UBR conns will not be accounted for.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmIispUPCSupp 3.1.1751.2.18.5.2.1.21
upc supp off/on
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

atmIispUbrLoadBalSupp 3.1.1751.2.18.5.2.1.22
load balancing supp for ubr conns off/on
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

atmIispSscopRxWndSz 3.1.1751.2.18.5.2.1.23
The receive window size for the SSCOP layer
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 8..256  

atmIispConnTrafficShapingFlag 3.1.1751.2.18.5.2.1.24
Traffic Shaping for Conn was enabled primarily because the core would lose cells since we were non-conformant cells. Therefore the hardware added traffic shaping per connection. But condition is VI should not be enabled if this feature is enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

atmCirEmConfigTable 3.1.1751.2.18.5.3
Table for ATM Circuit Emulation Interface
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmCirEmConfigEntry

atmCirEmConfigEntry 3.1.1751.2.18.5.3.1
Row definition for ATM Circuit Emulation interface
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmCirEmConfigEntry  

atmCirEmIfIndex 3.1.1751.2.18.5.3.1.1
interface index (slot/port/channel) SSPPCCC
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

atmCirEmAdminStatus 3.1.1751.2.18.5.3.1.2
The administrative action: 'outOfService' take the interface out of service 'inService' take the interface in service 'delete' remove/deconfigure the interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2), delete(3)  

atmCirEmOperStatus 3.1.1751.2.18.5.3.1.3
The operational status of the interface: 'outOfService' interface is out of service 'inService' interface is in service
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2)  

atmCirEmCASIdleAbcdPattern 3.1.1751.2.18.5.3.1.4
abcd bit pattern for cirEm AIS
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

atmCirEmCASBusyAbcdPattern 3.1.1751.2.18.5.3.1.5
abcd bit pattern for cirEm RDI
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

atmCirEmAlarmDataPattern 3.1.1751.2.18.5.3.1.6
data pattern for cirEm AIS
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

atmCirEmTCPattern 3.1.1751.2.18.5.3.1.7
Should abcd bits be toggled after 2.5 Secs.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER casIdle(1), casBusy(2)  

atmCirEmDownStInterworking 3.1.1751.2.18.5.3.1.8
This field will be used to select the type of interworking to be done in the down stream direction.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unSupp(1), oAM(2), trunkCond(3)  

atmTermEmConfigTable 3.1.1751.2.18.5.4
Table for ATM Terminal Emulation Interface
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmTermEmConfigEntry

atmTermEmConfigEntry 3.1.1751.2.18.5.4.1
Row definition for ATM Terminal Emulation interface
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmTermEmConfigEntry  

atmTermEmIfIndex 3.1.1751.2.18.5.4.1.1
interface index (slot/port/channel) SSPPCCC
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

atmTermEmRxTimeOut 3.1.1751.2.18.5.4.1.2
receive timeout value in tenths of seconds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 7..10  

atmTermEmAdminStatus 3.1.1751.2.18.5.4.1.3
The administrative action: 'outOfService' take the interface out of service 'inService' take the interface in service 'delete' remove/deconfigure the interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2), delete(3)  

atmTermEmOperStatus 3.1.1751.2.18.5.4.1.4
The operational status of the interface: 'outOfService' interface is out of service 'inService' interface is in service
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2)  

hdlcConfigTable 3.1.1751.2.18.5.5
Table for an HDLC Pass Through Interface
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HdlcConfigEntry

hdlcConfigEntry 3.1.1751.2.18.5.5.1
Row definition for an HDLC Pass Through interface
Status: current Access: not-accessible
OBJECT-TYPE    
  HdlcConfigEntry  

hdlcIfIndex 3.1.1751.2.18.5.5.1.1
interface index (slot/port/channel) SSPPCCC
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

hdlcAdminStatus 3.1.1751.2.18.5.5.1.2
The administrative action: 'outOfService' means take the interface out of service 'inService' means take the interface in service 'delete' remove/deconfigure the interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2), delete(3)  

hdlcOperStatus 3.1.1751.2.18.5.5.1.3
The operational status of the interface: 'outOfService' means the interface is out of service 'inService' means the interface is in service
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2)  

hdlcThroughPut 3.1.1751.2.18.5.5.1.4
The throughput bandwidth of the interface: 'k64' means a throughput of 64 kb 'k56' means a throughput of 56 kb
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER k64(1), k56(2)  

hdlcDataInversion 3.1.1751.2.18.5.5.1.5
Flag indicating whether data inversion is performed by the IO card for this interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

frUniConfigTable 3.1.1751.2.18.5.6
Table for Frame Realy UNI Interface
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FrUniConfigEntry

frUniConfigEntry 3.1.1751.2.18.5.6.1
Row definition for Frame Relay interface
Status: current Access: not-accessible
OBJECT-TYPE    
  FrUniConfigEntry  

frUniIfIndex 3.1.1751.2.18.5.6.1.1
interface index (slot/port/channel) SSPPCCC
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

frUniAddrDlciLen 3.1.1751.2.18.5.6.1.2
Length of Data Link connection identify of frame relay UNI address
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER twoOctets10Bits(1)  

frUniDlcmiState 3.1.1751.2.18.5.6.1.3
The state of Data Link Connection Management Indentify of frame relay UNI.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noLmi(1), lmiDte(2), lmiDce(3), lmiNni(4)  

frUniAdminStatus 3.1.1751.2.18.5.6.1.4
The administrative action: 'outOfService' take the interface out of service 'inService' take the interface in service 'delete' remove/deconfigure the interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2), delete(3)  

frUniOperStatus 3.1.1751.2.18.5.6.1.5
The operational status of the interface: 'outOfService' interface is out of service 'inService' interface is in service
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2)  

frUniOverSubscription 3.1.1751.2.18.5.6.1.6
Allow for the 'reserved' bandwidth allocated to oversubscribe the line by up to a factor of 10 . Generally, a figure of between 1 and 4 is normally a safe bet, although higher levels are often acceptable.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..10  

frUniLmiProtocol 3.1.1751.2.18.5.6.1.7
Lmi protocol to run
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), ccitt(2), ansi(3), att(4)  

frUniInterworkingType 3.1.1751.2.18.5.6.1.8
frf5 - fr/atm network interworking frf8 - fr/atm service interworking
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER frf5(1), frf8(2)  

frUniN391 3.1.1751.2.18.5.6.1.9
full status polling counter. DTE:Mandatory, DCE:N/A
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

frUniN392 3.1.1751.2.18.5.6.1.10
error threshold. DTE:Mandatory, DCE:Mandatory
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..10  

frUniN393 3.1.1751.2.18.5.6.1.11
Monitored event count. DTE:Mandatory, DCE:N/A
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..10  

frUniT391 3.1.1751.2.18.5.6.1.12
Link integrity verification timer. DTE:Mandatory, DCE:N/A
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 5..30  

frUniT392 3.1.1751.2.18.5.6.1.13
Polling verification timer. DTE:N/A, DCE:Mandatory
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 5..30  

frUniAsyncLmi 3.1.1751.2.18.5.6.1.14
Async PVC status messages
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

frLmiOperStatus 3.1.1751.2.18.5.6.1.15
The operational status of the lmi protocol: 'outOfService' interface is out of service 'inService' interface is in service
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2)  

frUniNT3 3.1.1751.2.18.5.6.1.16
Message frequency timer relevant for ATT LMI only.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 5..30  

frUniThroughPut 3.1.1751.2.18.5.6.1.17
The throughput bandwidth of the interface: 'k64' means a throughput of 64 kb 'k56' means a throughput of 56 kb
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER k64(1), k56(2)  

dspConfigTable 3.1.1751.2.18.5.7
Table for Dsp Interface
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DspConfigEntry

dspConfigEntry 3.1.1751.2.18.5.7.1
Row definition for Dsp interface
Status: current Access: not-accessible
OBJECT-TYPE    
  DspConfigEntry  

dspIfIndex 3.1.1751.2.18.5.7.1.1
interface index (slot/port/channel) SSPPCCC
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

dspAdminStatus 3.1.1751.2.18.5.7.1.2
The administrative action: 'outOfService' take the interface out of service 'inService' take the interface in service 'delete' remove/deconfigure the interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2), delete(3)  

dspOperStatus 3.1.1751.2.18.5.7.1.3
The operational status of the interface: 'outOfService' interface is out of service 'inService' interface is in service
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2)  

bridgeConfigTable 3.1.1751.2.18.5.8
Table which hold Config Entries for all bridges.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    BridgeConfigEntry

bridgeConfigEntry 3.1.1751.2.18.5.8.1
Row definition for bridge entries
Status: current Access: not-accessible
OBJECT-TYPE    
  BridgeConfigEntry  

bridgeIfIndex 3.1.1751.2.18.5.8.1.1
interface index (slot/port/channel) SSPPCCC
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

bridgeAdminStatus 3.1.1751.2.18.5.8.1.2
The administrative action: 'outOfService' take the interface out of service 'inService' take the interface in service 'delete' remove/deconfigure the interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2), delete(3)  

bridgeOperStatus 3.1.1751.2.18.5.8.1.3
The operational status of the interface: 'outOfService' interface is out of service 'inService' interface is in service
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2)  

bridgeNumber 3.1.1751.2.18.5.8.1.4
The number of bridges
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..999  

bridgePortPriority 3.1.1751.2.18.5.8.1.5
The value of the priority field which is contained in the first (in network byte order) octet of the (2 octet long) Port ID. The other octet of the Port ID is given by the value of dot1dStpPort.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

bridgePathCost 3.1.1751.2.18.5.8.1.6
The contribution of this port to the path cost of paths towards the spanning tree root which include this port. 802-1D-1990 recommends that the default value of this parameter be in inverse proportion to the speed of the attached LAN.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

bridgeConnectionType 3.1.1751.2.18.5.8.1.7
Connection types
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER vc(1), llc(2)  

bridgeDomainTable 3.1.1751.2.18.5.9
A table which holds the bridgeDomainEntry data
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    BridgeDomainEntry

bridgeDomainEntry 3.1.1751.2.18.5.9.1
A table entry for a Bridge Domain on an ethernet card
Status: current Access: not-accessible
OBJECT-TYPE    
  BridgeDomainEntry  

bridgeDomainNumber 3.1.1751.2.18.5.9.1.1
The bridge number of the bridge which this interface is a part of. If the interface is currently not associated with any bridge this will be set to none.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

bridgeDomainAdminStatus 3.1.1751.2.18.5.9.1.2
The administrative action: 'outOfService' take the interface out of service 'inService' take the interface in service
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2)  

bridgeDomainOperStatus 3.1.1751.2.18.5.9.1.3
The operational status of the interface: 'outOfService' interface is out of service 'inService' interface is in service
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2)  

bridgeDomainPriority 3.1.1751.2.18.5.9.1.4
The value of the writeable portion of the Bridge ID, i.e., the first two octets of the (8 octet long) Bridge ID. The other (last) 6 octets of the Bridge ID are given by the value of dot1dBaseBridgeAddress.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

bridgeDomainTimeSinceTopologyChange 3.1.1751.2.18.5.9.1.5
The time (in hundredths of a second) since the last time a topology change was detedted by the bridge entity.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

bridgeDomainDesignatedRoot 3.1.1751.2.18.5.9.1.6
The bridge identifier of the root of the spanning tree as determined by the Spanning Tree Protocol as executed by this node. This value is used as the Root Identifier parameter in all Configuration Bridge PDUs originated by this node.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

bridgeDomainRootCost 3.1.1751.2.18.5.9.1.7
The cost of the path to the root as seen from this bridge.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeDomainRootPort 3.1.1751.2.18.5.9.1.8
The port number of the port which offers the lowest cost path from this bridge to the root bridge.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeDomainMaxMessageAge 3.1.1751.2.18.5.9.1.9
The maximum age of Spanning Tree Protocol information learned from the network on any port before it is discarded, in units of hundredths of a second. This is the actual value that this bridge is currently using.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeDomainHelloTime 3.1.1751.2.18.5.9.1.10
The amount of time between the transmission of Configuration bridge PDUs by this node on any port when it is the root of the spanning tree or trying to become so, in units of hundredths of a second. This is the actual value that this bridge is currently using.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeDomainHoldTime 3.1.1751.2.18.5.9.1.11
This time value determines the interval length during which no more than two Configuration bridge PDUs shall be transmitted by this node, in units of hundredths of a second.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeDomainForwardDelay 3.1.1751.2.18.5.9.1.12
This time value, measured in units of hundredths of a second, controls how fast a port changes its state. The value determines how long the port stays in each of the Listening and Learning states, which precede the Forwarding state. This value is also used, when a topology change has been detected and is underway, to age all dynamic entries in the Forwarding Database. [Note that this value is the one that this bridge is currently using, in contrast to bridgeDomainBridgeForwardDelay which is the value that this bridge and all others would start using if/when this bridge were to become the root.]
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeDomainMaxBridgeAge 3.1.1751.2.18.5.9.1.13
The value that all bridges use for MaxAge when this bridge is acting as the root. Note that 802.1D-1990 specifies that the range for this parameter is related to the value of bridgeDomainBridgeHelloTime. The granularity of this timer is specified by 802.1D-1990 to be 1 second. An agent may return a badValue error if a set is attempted to a value which is not a whole number of seconds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 6..40  

bridgeDomainBridgeHelloTime 3.1.1751.2.18.5.9.1.14
The value that all bridges use for HelloTime when this bridge is acting as the root. The granularity of this timer is specified by 802.1D- 1990 to be 1 second. An agent may return a badValue error if a set is attempted to a value which is not a whole number of seconds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..10  

bridgeDomainBridgeForwardDelay 3.1.1751.2.18.5.9.1.15
The value that all bridges user for ForwardDelay when this bridge is acting as the root. Note that 802.1D-1990 specifies that the range for this parameter is related to the value of bridgeDomainMaxBridgeAge. The granularity of this timer is specified by 802.1D-1990 to be 1 second. An agent may return a badValue error if a set is attempted to a value which is not a whole number of seconds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 4..30  

bridgeDomainAgingTime 3.1.1751.2.18.5.9.1.16
The timeout period in seconds for aging out dynamically learned forwarding information. 802.1D-1990 recommends a default of 300 seconds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 10..1000000  

bridgeDomainSpanningTree 3.1.1751.2.18.5.9.1.17
Allows the bridge to be configured to run without the spanning tree algorithm.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

bridgeDomainTopologyChanges 3.1.1751.2.18.5.9.1.18
The total number of topology changes detected by this bridge since the management entity was last reset or initialized.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeDomainLearnedEntryDiscards 3.1.1751.2.18.5.9.1.19
The total number of Forwarding Database entries, which have been or would have been learnt, but have been discarded due to a lack of space to store them in the Forwarding Database. If this counter is increasing, it indicates that the Forwarding Database is regularly becoming full (a condition which has unpleasant performance effects on the subnetwork). If this counter has a significant value but is not presently increasing, it indicates that the problem has been occurring but is not persistent.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeDomainTimer 3.1.1751.2.18.5.9.1.20
Number of seconds elapsed since the last reset of bridge group statistics
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeDomainDefaultGateway 3.1.1751.2.18.5.9.1.21
The default gateway for this bridge domain. This is now an obsolete entry
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

bridgeDomainPortStatusBitmap 3.1.1751.2.18.5.9.1.22
A bit map describing which ports in a bridge group are up or down
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(30)  

routerConfigTable 3.1.1751.2.18.5.10
Table which hold Config Entries for all routers (VPNs)
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RouterConfigEntry

routerConfigEntry 3.1.1751.2.18.5.10.1
config data for a router (VPN)
Status: current Access: not-accessible
OBJECT-TYPE    
  RouterConfigEntry  

routerIfIndex 3.1.1751.2.18.5.10.1.1
A scalar number which identifies an IP interface within a given router (VPN)
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

routerAdminStatus 3.1.1751.2.18.5.10.1.2
The administrative action: 'outOfService' take the interface out of service 'inService' take the interface in service 'delete' remove/deconfigure the interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2), delete(3)  

routerOperStatus 3.1.1751.2.18.5.10.1.3
The operational status of the interface: 'outOfService' interface is out of service 'inService' interface is in service
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2)  

routerIpAddress 3.1.1751.2.18.5.10.1.4
router ATM IP Address.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

routerIpNetworkMask 3.1.1751.2.18.5.10.1.5
An IP network mask for an IP interface within a given router (VPN)
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

routerNumber 3.1.1751.2.18.5.10.1.6
A scalar number which identifies a given router (VPN)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..999  

routerEthernetIpAddress 3.1.1751.2.18.5.10.1.7
router Ethernet IP Address.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

isdnConfig 3.1.1751.2.18.5.11
OBJECT IDENTIFIER    

isdnIntfConfigTable 3.1.1751.2.18.5.11.1
Table of ISDN interface configuration attriburtes
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IsdnIntfConfigEntry

isdnIntfConfigEntry 3.1.1751.2.18.5.11.1.1
Row definition for ISDN interface configuration table
Status: current Access: not-accessible
OBJECT-TYPE    
  IsdnIntfConfigEntry  

isdnIntfId 3.1.1751.2.18.5.11.1.1.1
Interface ID (SSPPCCC)
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

isdnIntfDChanId 3.1.1751.2.18.5.11.1.1.2
D-Channel Number - if the Dchannel no. is 0 no LAPD will run on this PRI-ISDN interface
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..24  

isdnIntfAdminStatus 3.1.1751.2.18.5.11.1.1.3
ISDN interface admin status
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2), delete(3)  

isdnIntfOperStatus 3.1.1751.2.18.5.11.1.1.4
ISDN interface operational status
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2)  

isdnIntfSwitchType 3.1.1751.2.18.5.11.1.1.5
ISDN interface Switch Type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER pri-ni2(1), pri-net5(2), pri-1tr6(3), pri-4ess(4), pri-5ess(5), pri-dass2(6), pri-dms100(7), pri-kdd(8), pri-ntt(9), pri-net5sw(10), pri-ts014(11), pri-vn(12)  

isdnL2ConfigTable 3.1.1751.2.18.5.11.2
Table of Layer 2 (LAPD) attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IsdnL2ConfigEntry

isdnL2ConfigEntry 3.1.1751.2.18.5.11.2.1
Row definition for ISDN LAPD parameters
Status: current Access: not-accessible
OBJECT-TYPE    
  IsdnL2ConfigEntry  

isdnL2IntfId 3.1.1751.2.18.5.11.2.1.1
Interface index (SSPPCCC)
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

isdnT200 3.1.1751.2.18.5.11.2.1.2
value of L2 T200 timer in 1/10 seconds
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..100  

isdnT203 3.1.1751.2.18.5.11.2.1.3
value of L2 T203 timer in seconds
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..60  

isdnN200 3.1.1751.2.18.5.11.2.1.4
Maximum number of retransmissions before the LAPD Link is declared as down
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..5  

isdnN201 3.1.1751.2.18.5.11.2.1.5
Maximum number of octets in an information field - Maximum value of this parameter will be 300 bytes.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..300  

isdnK 3.1.1751.2.18.5.11.2.1.6
Maximum number of outstanding I frames - L2 - window size.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..127  

isdnL2OperStatus 3.1.1751.2.18.5.11.2.1.7
ISDN Layer 2 operational status - not-initiated means that first SETUP message has not been transmitted and L2 estalishment procedure has not been initiated yet
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER not-initiated(1), up(2), down(3)  

isdnL2CurrentState 3.1.1751.2.18.5.11.2.1.8
ISDN Layer 2 protocol's current state
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER tei-unassigned(1), tei-assigned(4), awaiting-establishment(5), awaiting-release(6), multiple-frame-established(7), timer-recovery(8)  

isdnBChanConfigTable 3.1.1751.2.18.5.11.3
Table of ISDN B Channel configuration attriburtes
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IsdnBChanConfigEntry

isdnBChanConfigEntry 3.1.1751.2.18.5.11.3.1
Row definition for ISDN B Channel configuration table
Status: current Access: not-accessible
OBJECT-TYPE    
  IsdnBChanConfigEntry  

isdnBChanId 3.1.1751.2.18.5.11.3.1.1
B Chan ID (SSPPCCC)
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

isdnBChanAdminStatus 3.1.1751.2.18.5.11.3.1.2
ISDN B Chan admin status
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2)  

isdnBChanOperStatus 3.1.1751.2.18.5.11.3.1.3
ISDN B Chan operational status
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2)  

atmDbCirEmConfigTable 3.1.1751.2.18.5.12
Table for ATM DBCES Interface
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmDbCirEmConfigEntry

atmDbCirEmConfigEntry 3.1.1751.2.18.5.12.1
Row definition for ATM Dynamic Bandwidth Circuit Emulation interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmDbCirEmConfigEntry  

atmDbCirEmIfIndex 3.1.1751.2.18.5.12.1.1
Interface index (slot/port/channel) SSPPCCC.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

atmDbCirEmAdminStatus 3.1.1751.2.18.5.12.1.2
The administrative action: 'outOfService' take the interface out of service 'inService' take the interface in service 'delete' remove/deconfigure the interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2), delete(3)  

atmDbCirEmOperStatus 3.1.1751.2.18.5.12.1.3
The operational status of the interface: 'outOfService' interface is out of service 'inService' interface is in service
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2)  

atmDbCirEmIdlePattern 3.1.1751.2.18.5.12.1.7
Idle pattern for idle data.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmDbCirEmServiceType 3.1.1751.2.18.5.12.1.8
Service type to be used. Affects the ABCD Signaling.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER plar(1), fxo-loopstart(2), fxs-loopstart(3), fxo-groundstart(4), fxs-groundstart(5)  

atmDbCirEmDbcesType 3.1.1751.2.18.5.12.1.9
The type of dbces used. yurie: Yurie proprietary specific.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER lucent(1)  

atmDbCirEmIntegrationTime 3.1.1751.2.18.5.12.1.10
This specifies the time to wait after receiving idle pattern to change state. The unit is in seconds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

lmiDlciConfigTable 3.1.1751.2.18.5.13
Table for Lmi DLCI Interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LmiDlciConfigEntry

lmiDlciConfigEntry 3.1.1751.2.18.5.13.1
Row definition for Lmi DLCI Interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  LmiDlciConfigEntry  

lmiDlciIfIndex 3.1.1751.2.18.5.13.1.1
Interface index (slot/port/channel) SSPPCCC.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

lmiDlci 3.1.1751.2.18.5.13.1.2
dlci.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

lmiDlciOperStatus 3.1.1751.2.18.5.13.1.3
The operational status of the lmi protocol: 'outOfService' protocol is out of service 'inService' protocol is in service
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2)  

lmiDlciStatusTime 3.1.1751.2.18.5.13.1.4
Time since last status transition occurred.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

dsp2ConfigTable 3.1.1751.2.18.5.14
Table for Dsp2 Interface
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Dsp2ConfigEntry

dsp2ConfigEntry 3.1.1751.2.18.5.14.1
Row definition for Dsp2 interface
Status: current Access: not-accessible
OBJECT-TYPE    
  Dsp2ConfigEntry  

dsp2IfIndex 3.1.1751.2.18.5.14.1.1
interface index (slot/port/channel) SSPPCCC
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

dsp2AdminStatus 3.1.1751.2.18.5.14.1.2
The administrative action: 'outOfService' take the interface out of service 'inService' take the interface in service 'delete' remove/deconfigure the interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2), delete(3)  

dsp2OperStatus 3.1.1751.2.18.5.14.1.3
The operational status of the interface: 'outOfService' interface is out of service 'inService' interface is in service
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2)  

dsp2LoadCount 3.1.1751.2.18.5.14.1.4
Gives the number of calls going through that dsp. This will be of use in case of deletion of dsp interface. When no calls are going through the dsp this value will be 0
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

dsp2AalMode 3.1.1751.2.18.5.14.1.5
aal2-non-multiplexed : Does not support multiplexing of multiple channels with one trunk aal2-standard: Support Standard Aal2 Multiplexing aal1:Support Aal1 mode.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER aal2-non-multiplexed(1), aal2-standard(2), aal1(3)  

atmImaConfigTable 3.1.1751.2.18.5.15
Inverse Multiplexing interface table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmImaConfigEntry

atmImaConfigEntry 3.1.1751.2.18.5.15.1
Row definition for Inverse Multiplexing attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmImaConfigEntry  

atmImaIntfIndex 3.1.1751.2.18.5.15.1.1
interface index (slot/port/channel) SSPPCCC
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

atmImaNeTxState 3.1.1751.2.18.5.15.1.2
The near-end transmit state. notInGroup -- Interface is not assigned to group unusableNoReason -- Doesn't work; Don't know why. unusableFailed -- Check the Defect value usable -- Interface is ready to go. active -- Interface is in use.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notInGroup(1), unusableNoReason(2), unusableFault(3), unusableMisconnected(4), unusableInhibited(5), unusableFailed(6), usable(7), active(8)  

atmImaNeRxState 3.1.1751.2.18.5.15.1.3
The near-end receive state. notInGroup -- Interface is not assigned to group unusableNoReason -- Doesn't work; Don't know why. unusableFailed -- Check the Defect value usable -- Interface is ready to go. active -- Interface is in use.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notInGroup(1), unusableNoReason(2), unusableFault(3), unusableMisconnected(4), unusableInhibited(5), unusableFailed(6), usable(7), active(8)  

atmImaFeTxState 3.1.1751.2.18.5.15.1.4
The far-end transmit state. notInGroup -- Interface is not assigned to group unusableNoReason -- Doesn't work; Don't know why. unusableFailed -- Check the Defect value usable -- Interface is ready to go. active -- Interface is in use.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notInGroup(1), unusableNoReason(2), unusableFault(3), unusableMisconnected(4), unusableInhibited(5), unusableFailed(6), usable(7), active(8)  

atmImaFeRxState 3.1.1751.2.18.5.15.1.5
The far-end receive state. notInGroup -- Interface is not assigned to group unusableNoReason -- Doesn't work; Don't know why. unusableFailed -- Check the Defect value usable -- Interface is ready to go. active -- Interface is in use.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notInGroup(1), unusableNoReason(2), unusableFault(3), unusableMisconnected(4), unusableInhibited(5), unusableFailed(6), usable(7), active(8)  

atmImaNeRxDefect 3.1.1751.2.18.5.15.1.6
The near-end receive defect. noDefect -- No link defect exists linkFailure -- Physical failure/ Loss of signal lifDefect -- Persistence of LIF defect at near-end (Loss of IMA Frame) lodsDefect -- Persistence of LODS defect at near-end (Link Out of Delay Synchronization)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noDefect(1), linkFailure(2), lif(3), lods(4)  

atmImaFeRxDefect 3.1.1751.2.18.5.15.1.7
The far-end receive defect. noDefect -- No link defect exists linkFailure -- Physical failure/ Loss of signal lifDefect -- Persistence of LIF defect at near-end (Loss of IMA Frame) lodsDefect -- Persistence of LODS defect at near-end (Link Out of Delay Synchronization)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noDefect(1), linkFailure(2), lif(3), lods(4)  

atmImaAdminStatus 3.1.1751.2.18.5.15.1.8
The administrative action: 'outOfService' take the interface out of service 'inService' take the interface in service 'delete' remove/deconfigure the interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2), delete(3)  

atmImaOperStatus 3.1.1751.2.18.5.15.1.9
The operational status of the interface: 'outOfService' interface is out of service 'inService' interface is in service
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2)  

atmPnniConfigTable 3.1.1751.2.18.5.16
Table of atm PNNI Configuration
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmPnniConfigEntry

atmPnniConfigEntry 3.1.1751.2.18.5.16.1
Row definition of PNNI Configuration
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmPnniConfigEntry  

atmPnniIfIndex 3.1.1751.2.18.5.16.1.1
interface index (slot/port/channel) SSPPCCC
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

atmPnniSvcMinVpi 3.1.1751.2.18.5.16.1.2
The lower bound of the VPI for SVC connections.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

atmPnniSvcMaxVpi 3.1.1751.2.18.5.16.1.3
The upper bound of the VPI for SVC connections.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

atmPnniSvcMinVci 3.1.1751.2.18.5.16.1.4
The lower bound of the VCI for SVC connections.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

atmPnniSvcMaxVci 3.1.1751.2.18.5.16.1.5
The upper bound of the VCI for SVC connections.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

atmPnniAdminStatus 3.1.1751.2.18.5.16.1.6
The administrative action: 'outOfService' means take the PNNI out of service 'inService' means take the PNNI in service 'delete' remove/deconfigure the PNNI.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2), delete(3)  

atmPnniOperStatus 3.1.1751.2.18.5.16.1.7
The operational status of the PNNI: 'outOfService' means the PNNI is out of service 'inService' means the PNNI is in service
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2)  

atmPnniT303 3.1.1751.2.18.5.16.1.8
Timer T303 value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPnniT308 3.1.1751.2.18.5.16.1.9
Timer T308 value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPnniT309 3.1.1751.2.18.5.16.1.10
Timer T309 value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPnniT310 3.1.1751.2.18.5.16.1.11
Timer T310 value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPnniT313 3.1.1751.2.18.5.16.1.12
Timer T313 value - User side only - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPnniT316 3.1.1751.2.18.5.16.1.13
Timer T316 value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPnniT317 3.1.1751.2.18.5.16.1.14
Timer T317 value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPnniT322 3.1.1751.2.18.5.16.1.15
Timer T322 value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPnniT397 3.1.1751.2.18.5.16.1.16
Timer T397 value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPnniT398 3.1.1751.2.18.5.16.1.17
Timer T398 value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPnniT399 3.1.1751.2.18.5.16.1.18
Timer T399 value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPnniCbrServCatSupp 3.1.1751.2.18.5.16.1.19
If CBR category is supported
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

atmPnniCbrGcacClpEqualZero 3.1.1751.2.18.5.16.1.20
If the advertised GCAC parameters apply for CLP=0 or CLP=0+1 traffic
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

atmPnniCbrMaxCellRate 3.1.1751.2.18.5.16.1.21
CBR category Maximum Cell Rate
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPnniCbrAvailCellRate 3.1.1751.2.18.5.16.1.22
CBR category Available Cell Rate
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPnniCbrCellXerDelay 3.1.1751.2.18.5.16.1.23
CBR category Cell Transfer Delay
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPnniCbrCellLossRatioZero 3.1.1751.2.18.5.16.1.24
CBR category Cell Loss Ratio for CLP=0 traffic
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPnniCbrCellLossRatioZeroPlusOne 3.1.1751.2.18.5.16.1.25
CBR category Cell Loss Ratio for CLP=0+1 traffic
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPnniCbrCellDelayVar 3.1.1751.2.18.5.16.1.26
CBR category Cell Delay Variation
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPnniRtVbrServCatSupp 3.1.1751.2.18.5.16.1.27
If RT VBR category is supported
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

atmPnniRtVbrGcacClpEqualZero 3.1.1751.2.18.5.16.1.28
If the advertised GCAC parameters apply for CLP=0 or CLP=0+1 traffic
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

atmPnniRtVbrMaxCellRate 3.1.1751.2.18.5.16.1.29
RT VBR category Maximum Cell Rate
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPnniRtVbrAvailCellRate 3.1.1751.2.18.5.16.1.30
RT VBR category Available Cell Rate
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPnniRtVbrCellXerDelay 3.1.1751.2.18.5.16.1.31
RT VBR category Cell Transfer Delay
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPnniRtVbrCellLossRatioZero 3.1.1751.2.18.5.16.1.32
RT VBR category Cell Loss Ratio for CLP=0 traffic
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPnniRtVbrCellLossRatioZeroPlusOne 3.1.1751.2.18.5.16.1.33
RT VBR category Cell Loss Ratio for CLP=0+1 traffic
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPnniRtVbrCellDelayVar 3.1.1751.2.18.5.16.1.34
RT VBR category Cell Delay Variation
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPnniRtVbrGcacPresent 3.1.1751.2.18.5.16.1.35
If RT VBR category GCAC Parameters present
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

atmPnniRtVbrCellRateMargin 3.1.1751.2.18.5.16.1.36
RT VBR category Cell Rate Margin
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

atmPnniRtVbrVarianceFactor 3.1.1751.2.18.5.16.1.37
RT VBR category Variance Factor
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

atmPnniNrtVbrServCatSupp 3.1.1751.2.18.5.16.1.38
If NRT VBR category is supported
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

atmPnniNrtVbrGcacClpEqualZero 3.1.1751.2.18.5.16.1.39
If the advertised GCAC parameters apply for CLP=0 or CLP=0+1 traffic
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

atmPnniNrtVbrMaxCellRate 3.1.1751.2.18.5.16.1.40
NRT VBR category Maximum Cell Rate
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPnniNrtVbrAvailCellRate 3.1.1751.2.18.5.16.1.41
NRT VBR category Available Cell Rate
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPnniNrtVbrCellXerDelay 3.1.1751.2.18.5.16.1.42
NRT VBR category Cell Transfer Delay
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPnniNrtVbrCellLossRatioZero 3.1.1751.2.18.5.16.1.43
NRT VBR category Cell Loss Ratio for CLP=0 traffic
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPnniNrtVbrCellLossRatioZeroPlusOne 3.1.1751.2.18.5.16.1.44
NRT VBR category Cell Loss Ratio for CLP=0+1 traffic
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPnniNrtVbrGcacPresent 3.1.1751.2.18.5.16.1.45
If NRT VBR category GCAC Parameters present
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

atmPnniNrtVbrCellRateMargin 3.1.1751.2.18.5.16.1.46
NRT VBR category Cell Rate Margin
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

atmPnniNrtVbrVarianceFactor 3.1.1751.2.18.5.16.1.47
NRT VBR category Variance Factor
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

atmPnniAbrServCatSupp 3.1.1751.2.18.5.16.1.48
If ABR category is supported
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

atmPnniAbrMaxCellRate 3.1.1751.2.18.5.16.1.49
ABR category Maximum Cell Rate
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPnniAbrAvailCellRate 3.1.1751.2.18.5.16.1.50
ABR category Available Cell Rate
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPnniUbrServCatSupp 3.1.1751.2.18.5.16.1.51
UBR category Cell Transfer Delay
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

atmPnniUbrMaxCellRate 3.1.1751.2.18.5.16.1.52
NRT VBR category Cell Loss Ratio for CLP=0 traffic
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPnniOverSubscription 3.1.1751.2.18.5.16.1.53
Over subscription factor for PNNI Intf.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..100  

atmPnniSgnlEnabled 3.1.1751.2.18.5.16.1.54
Indicates if atm signaling is enabled or disabled for this PNNI interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

atmPnniVpiSig 3.1.1751.2.18.5.16.1.55
VPI value for the signalling channel for the PNNI interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

atmPnniVciSig 3.1.1751.2.18.5.16.1.56
VCI value for the signalling channel for the PNNI interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..31  

atmPnniAvailBwIgr 3.1.1751.2.18.5.16.1.57
The Avail Bandwidth for that interface in cells per sec. Bandwidth for UBR conns will not be accounted for.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPnniAvailBwEgr 3.1.1751.2.18.5.16.1.58
The Avail Bandwidth for that interface in cells per sec. Bandwidth for UBR conns will not be accounted for.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPnniUPCSupp 3.1.1751.2.18.5.16.1.59
upc supp off/on
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

atmPnniUbrLoadBalSupp 3.1.1751.2.18.5.16.1.60
load balancing supp for ubr conns off/on
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

atmPnniSscopRxWndSz 3.1.1751.2.18.5.16.1.61
The receive window size for the SSCOP layer
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 8..256  

atmPnniRemoteSvcMinVpi 3.1.1751.2.18.5.16.1.62
The lower bound of the actual VPI for SVC connections.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..4095  

atmPnniRemoteSvcMaxVpi 3.1.1751.2.18.5.16.1.63
The Upper bound of the actual VPI for SVC connections.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..4095  

atmPnniRemoteSvcMinVci 3.1.1751.2.18.5.16.1.64
The lower bound of the actual VCI for SVC connections.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 32..65535  

atmPnniRemoteSvcMaxVci 3.1.1751.2.18.5.16.1.65
The Upper bound of the actual VCI for SVC connections.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 32..65535  

atmPnniVpiIlmi 3.1.1751.2.18.5.16.1.66
VPI value for the ilmi channel for the PNNI interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

atmPnniVciIlmi 3.1.1751.2.18.5.16.1.67
VCI value for the ilmi channel for the PNNI interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..31  

atmPnniIlmiProtocolStatus 3.1.1751.2.18.5.16.1.68
The administrative status: 'enabled' - ILMI protocol enabled on PNNI 'disabled' - ILMI protocol disabled on PNNI .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

atmPnniIlmiOperStatus 3.1.1751.2.18.5.16.1.69
The operational status: 'outOfService' - ILMI connectivity is down 'inService' - ILMI connectivity is up.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2)  

atmPnniIlmiConfigProc 3.1.1751.2.18.5.16.1.70
ILMI Configuration Procedure status.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

atmPnniIlmiConnectProc 3.1.1751.2.18.5.16.1.71
ILMI Connectivity Procedure status.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

atmPnniIlmiAttachPtProc 3.1.1751.2.18.5.16.1.72
ILMI Attachment Point Procedure status.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

atmPnniIlmiSecureLinkProc 3.1.1751.2.18.5.16.1.73
ILMI Secure Link Procedure status. Can be enabled only if Attachment Point Procedure is enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

atmPnniIlmiAddrRegProc 3.1.1751.2.18.5.16.1.74
ILMI Address Registration Procedure status.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

atmPnniIlmiTimerS 3.1.1751.2.18.5.16.1.75
Timer S (secs). Used to poll peer when link is down.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPnniIlmiTimerT 3.1.1751.2.18.5.16.1.76
Timer T (secs). Used to poll peer when link is up.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPnniIlmiRetryK 3.1.1751.2.18.5.16.1.77
Retry K - number of timeouts of before link is declared down.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPnniConnTrafficShapingFlag 3.1.1751.2.18.5.16.1.78
Traffic Shaping for Conn was enabled primarily because the core would lose cells since we were non-conformant cells. Therefore the hardware added traffic shaping per connection. But condition is VI should not be enabled if this feature is enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

atmVnnConfigTable 3.1.1751.2.18.5.17
Table of atm user to network interface (UNI)
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVnnConfigEntry

atmVnnConfigEntry 3.1.1751.2.18.5.17.1
Row definition of atm UNI
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVnnConfigEntry  

atmVnnIfIndex 3.1.1751.2.18.5.17.1.1
interface index (slot/port/channel) SSPPCCC
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

atmVnnAddrType 3.1.1751.2.18.5.17.1.2
atm address type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER nsap(1), e164(2), private(3)  

atmVnnSvcMinVpi 3.1.1751.2.18.5.17.1.3
The lower bound of the VPI for SVC connections.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

atmVnnSvcMaxVpi 3.1.1751.2.18.5.17.1.4
The upper bound of the VPI for SVC connections.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

atmVnnSvcMinVci 3.1.1751.2.18.5.17.1.5
The lower bound of the VCI for SVC connections.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

atmVnnSvcMaxVci 3.1.1751.2.18.5.17.1.6
The upper bound of the VCI for SVC connections.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

atmVnnAdminStatus 3.1.1751.2.18.5.17.1.7
The administrative action: 'outOfService' means take the UNI out of service 'inService' means take the UNI in service 'delete' remove/deconfigure the UNI.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2), delete(3)  

atmVnnOperStatus 3.1.1751.2.18.5.17.1.8
The operational status of the UNI: 'outOfService' means the UNI is out of service 'inService' means the UNI is in service
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2)  

atmVnnOverSubscription 3.1.1751.2.18.5.17.1.9
Over subscription factor
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..100  

atmVnnNwPrefix1 3.1.1751.2.18.5.17.1.10
ATM Network Prefix 1
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(13)  

atmVnnT303 3.1.1751.2.18.5.17.1.11
Timer T303 value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmVnnT308 3.1.1751.2.18.5.17.1.12
Timer T308 value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmVnnT309 3.1.1751.2.18.5.17.1.13
Timer T309 value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmVnnT310 3.1.1751.2.18.5.17.1.14
Timer T310 value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmVnnT313 3.1.1751.2.18.5.17.1.15
Timer T313 value - User side only - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmVnnT316 3.1.1751.2.18.5.17.1.16
Timer T316 value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmVnnT317 3.1.1751.2.18.5.17.1.17
Timer T317 value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmVnnT322 3.1.1751.2.18.5.17.1.18
Timer T322 value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmVnnT398 3.1.1751.2.18.5.17.1.19
Timer T398 value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmVnnT399 3.1.1751.2.18.5.17.1.20
Timer T399 value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmVnnMyNeighborIpAddress 3.1.1751.2.18.5.17.1.21
The IP address of the neighbor system connected to the far end of this interface, to which a Network Management Station can send SNMP messages, as IP datagrams sent to UDP port 161, in order to access network management information concerning the operation of that system. Note that the value of this object can currently only be obtained by manual configuration.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

atmVnnMyNeighborIfName 3.1.1751.2.18.5.17.1.22
The textual name of the interface on the neighbor system on the far end of this interface, and to which this interface connects. If the neighbor system is manageable through SNMP and supports the object ifName, the value of this object must be identical with that of ifName for the ifEntry of the lowest level physical interface for this port. If this interface does not have a textual name, the value of this object is a zero length string. Note that the value of this object can currently only be obtained by manual configuration.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(20)  

atmVnnVpiSig 3.1.1751.2.18.5.17.1.23
VPI value for the signalling channel for the UNI interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

atmVnnVciSig 3.1.1751.2.18.5.17.1.24
VCI value for the signalling channel for the UNI interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..31  

atmVnnVpiIlmi 3.1.1751.2.18.5.17.1.25
VPI value for the ilmi channel for the UNI interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

atmVnnVciIlmi 3.1.1751.2.18.5.17.1.26
VCI value for the ilmi channel for the UNI interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..31  

atmVnnAtmSignalingStatus 3.1.1751.2.18.5.17.1.27
Indicates if atm signaling is enabled or disabled for this interface. Consistent with other AC interfaces
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1)  

atmVnnMyIfName 3.1.1751.2.18.5.17.1.28
A textual name of this interface. If this system is manageable manageable through SNMP and supports the object ifName, the value of this object must be identical with that of ifName for the ifEntry of the lowest level physical interface for this port. This interface must be uniquely named on this system to distinguish parallel links with a neighboring system. If this interface does not have a textual name, the value of this object is a zero length string.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(20)  

atmVnnIlmiProtocolStatus 3.1.1751.2.18.5.17.1.29
The administrative status: 'enabled' - ILMI protocol enabled on UNI.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1)  

atmVnnIlmiOperStatus 3.1.1751.2.18.5.17.1.30
The operational status: 'outOfService' - ILMI connectivity is down 'inService' - ILMI connectivity is up.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2)  

atmVnnIlmiConfigProc 3.1.1751.2.18.5.17.1.31
ILMI Configuration Procedure status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER disabled(2)  

atmVnnIlmiConnectProc 3.1.1751.2.18.5.17.1.32
ILMI Connectivity Procedure status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1)  

atmVnnIlmiAttachPtProc 3.1.1751.2.18.5.17.1.33
ILMI Attachment Point Procedure status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER disabled(2)  

atmVnnIlmiSecureLinkProc 3.1.1751.2.18.5.17.1.34
ILMI Secure Link Procedure status. Can be enabled only if Attachment Point Procedure is enabled.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER disabled(2)  

atmVnnIlmiAddrRegProc 3.1.1751.2.18.5.17.1.35
ILMI Address Registration Procedure status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1)  

atmVnnIlmiTimerS 3.1.1751.2.18.5.17.1.36
Timer S (secs). Used to poll peer when link is down.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmVnnIlmiTimerT 3.1.1751.2.18.5.17.1.37
Timer T (secs). Used to poll peer when link is up.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmVnnIlmiRetryK 3.1.1751.2.18.5.17.1.38
Retry K - number of timeouts before link is declared down.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmVnnAvailBwIgr 3.1.1751.2.18.5.17.1.39
The Avail Bandwidth for that interface in cells per sec. Bandwidth for UBR conns will not be accounted for.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVnnAvailBwEgr 3.1.1751.2.18.5.17.1.40
The Avail Bandwidth for that interface in cells per sec. Bandwidth for UBR conns will not be accounted for.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVnnUPCSupp 3.1.1751.2.18.5.17.1.41
upc supp off/on
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

atmVnnUbrLoadBalSupp 3.1.1751.2.18.5.17.1.42
load balancing supp for ubr conns off/on
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

atmVnnSscopRxWndSz 3.1.1751.2.18.5.17.1.43
The receive window size for the SSCOP layer
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 8..256  

virtualIntfConfigTable 3.1.1751.2.18.5.18
Table of Virtual Interfaces Configurations
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VirtualIntfConfigEntry

virtualIntfConfigEntry 3.1.1751.2.18.5.18.1
Index is the Interface and the Virutal Interface
Status: current Access: not-accessible
OBJECT-TYPE    
  VirtualIntfConfigEntry  

virtualIntfConfigIf 3.1.1751.2.18.5.18.1.1
Interface index for side A of an ATM-to-ATM PVC VCC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

virtualIntfConfigVi 3.1.1751.2.18.5.18.1.2
VI value. Def Val is 1 because 0 cannot be configured
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..1024  

virtualIntfConfigCellRate 3.1.1751.2.18.5.18.1.3
Bandwidth assigned for the VI. The unit is cells per sec. Total Bandwidth of all VI's cannot exceed bandwidth of the main interface. CAC will be supported per VI.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

virtualIntfConfigOverSubs 3.1.1751.2.18.5.18.1.4
Over Subscription rate for VI
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

virtualIntfConfigRowStatus 3.1.1751.2.18.5.18.1.5
row status
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

virtualIntfConfigUPCSupp 3.1.1751.2.18.5.18.1.6
virtual interface upc supp off/on If this is changed then all the connections on this interface will be replayed.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

virtualIntfAvailBwEgr 3.1.1751.2.18.5.18.1.7
Avail Bw for that VI in cells per sec in the Egress Direction or the direction away from back plane.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

virtualUNIConfigTable 3.1.1751.2.18.5.19
Table of Virtual UNI Interfaces Configurations
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VirtualUNIConfigEntry

virtualUNIConfigEntry 3.1.1751.2.18.5.19.1
Index is the Interface and the Virutal UNI Interface
Status: current Access: not-accessible
OBJECT-TYPE    
  VirtualUNIConfigEntry  

virtualUNIIfIndex 3.1.1751.2.18.5.19.1.1
This is the first index to the Virtual UNI Interface table. Interface index will be of the form SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

virtualUNIVUNIId 3.1.1751.2.18.5.19.1.2
Virtual UNI number, second index to access the virtual UNI interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..255  

virtualUNIVISupport 3.1.1751.2.18.5.19.1.3
Virtual Interface (Traffic Shaping) is enabled or disabled on this VUNI. A Virtual Interface should already be configured befaore the traffic shaping can be enabled on this VUNI. If VISupport is disabled then all the connections on the VUNI can only be configured as UBR connections if this VUNI interface is on a VI enabled physical interface
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

virtualUNIMinVpi 3.1.1751.2.18.5.19.1.4
Lower value of the VPI range for this VUNI
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

virtualUNIMaxVpi 3.1.1751.2.18.5.19.1.5
Upper value of the VPI range for this VUNI
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

virtualUNIConfigRowStatus 3.1.1751.2.18.5.19.1.6
row status
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

virtualUNIAddrType 3.1.1751.2.18.5.19.1.7
atm address type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER nsap(1), e164(2), private(3)  

virtualUNISvcMinVpi 3.1.1751.2.18.5.19.1.8
The lower bound of the VPI for SVC connections.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

virtualUNISvcMaxVpi 3.1.1751.2.18.5.19.1.9
The upper bound of the VPI for SVC connections.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

virtualUNISvcMinVci 3.1.1751.2.18.5.19.1.10
The lower bound of the VCI for SVC connections.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

virtualUNISvcMaxVci 3.1.1751.2.18.5.19.1.11
The upper bound of the VCI for SVC connections.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

virtualUNIAdminStatus 3.1.1751.2.18.5.19.1.12
The administrative action: 'outOfService' means take the VUNI out of service 'inService' means take the VUNI in service
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2)  

virtualUNIOperStatus 3.1.1751.2.18.5.19.1.13
The operational status of the VUNI: 'outOfService' means the VUNI is out of service 'inService' means the VUNI is in service
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2)  

virtualUNINwPrefix1 3.1.1751.2.18.5.19.1.14
ATM Network Prefix 1
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(13)  

virtualUNIT303 3.1.1751.2.18.5.19.1.15
Timer T303 value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

virtualUNIT308 3.1.1751.2.18.5.19.1.16
Timer T308 value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

virtualUNIT309 3.1.1751.2.18.5.19.1.17
Timer T309 value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

virtualUNIT310 3.1.1751.2.18.5.19.1.18
Timer T310 value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

virtualUNIT313 3.1.1751.2.18.5.19.1.19
Timer T313 value - User side only - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

virtualUNIT316 3.1.1751.2.18.5.19.1.20
Timer T316 value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

virtualUNIT317 3.1.1751.2.18.5.19.1.21
Timer T317 value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

virtualUNIT322 3.1.1751.2.18.5.19.1.22
Timer T322 value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

virtualUNIT398 3.1.1751.2.18.5.19.1.23
Timer T398 value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

virtualUNIT399 3.1.1751.2.18.5.19.1.24
Timer T399 value - seconds
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

virtualUNIMyNeighborIpAddress 3.1.1751.2.18.5.19.1.25
The IP address of the neighbor system connected to the far end of this interface, to which a Network Management Station can send SNMP messages, as IP datagrams sent to UDP port 161, in order to access network management information concerning the operation of that system. Note that the value of this object can currently only be obtained by manual configuration.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

virtualUNIMyNeighborIfName 3.1.1751.2.18.5.19.1.27
The textual name of the interface on the neighbor system on the far end of this interface, and to which this interface connects. If the neighbor system is manageable through SNMP and supports the object ifName, the value of this object must be identical with that of ifName for the ifEntry of the lowest level physical interface for this port. If this interface does not have a textual name, the value of this object is a zero length string. Note that the value of this object can currently only be obtained by manual configuration.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(20)  

virtualUNIVpiSig 3.1.1751.2.18.5.19.1.28
VPI value for the signalling channel for the UNI interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

virtualUNIVciSig 3.1.1751.2.18.5.19.1.29
VCI value for the signalling channel for the UNI interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..31  

virtualUNISignalingAdminStatus 3.1.1751.2.18.5.19.1.30
Indicates if atm signaling is enabled or disabled for this VUNI interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

virtualUNISignalingOperStatus 3.1.1751.2.18.5.19.1.31
The protocol operational status of the UNI: 'outOfService' means the UNI is out of service 'inService' means the UNI is in service
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER inService(1), outOfService(2)  

virtualUNIVpiIlmi 3.1.1751.2.18.5.19.1.32
VPI value for the ilmi channel for the UNI interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

virtualUNIVciIlmi 3.1.1751.2.18.5.19.1.33
VCI value for the ilmi channel for the UNI interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..31  

virtualUNIMyIfName 3.1.1751.2.18.5.19.1.34
A textual name of this interface. If this system is manageable manageable through SNMP and supports the object ifName, the value of this object must be identical with that of ifName for the ifEntry of the lowest level physical interface for this port. This interface must be uniquely named on this system to distinguish parallel links with a neighboring system. If this interface does not have a textual name, the value of this object is a zero length string.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(20)  

virtualUNIIlmiProtocolStatus 3.1.1751.2.18.5.19.1.35
The administrative status: 'enabled' - ILMI protocol enabled on UNI 'disabled' - ILMI protocol disabled on UNI.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

virtualUNIIlmiOperStatus 3.1.1751.2.18.5.19.1.36
The operational status: 'outOfService' - ILMI connectivity is down 'inService' - ILMI connectivity is up.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2)  

virtualUNIIlmiConfigProc 3.1.1751.2.18.5.19.1.37
ILMI Configuration Procedure status.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

virtualUNIIlmiConnectProc 3.1.1751.2.18.5.19.1.38
ILMI Connectivity Procedure status.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

virtualUNIIlmiAttachPtProc 3.1.1751.2.18.5.19.1.39
ILMI Attachment Point Procedure status.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

virtualUNIIlmiSecureLinkProc 3.1.1751.2.18.5.19.1.40
ILMI Secure Link Procedure status. Can be enabled only if Attachment Point Procedure is enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

virtualUNIIlmiAddrRegProc 3.1.1751.2.18.5.19.1.41
ILMI Address Registration Procedure status.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

virtualUNIIlmiTimerS 3.1.1751.2.18.5.19.1.42
Timer S (secs). Used to poll peer when link is down.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

virtualUNIIlmiTimerT 3.1.1751.2.18.5.19.1.43
Timer T (secs). Used to poll peer when link is up.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

virtualUNIIlmiRetryK 3.1.1751.2.18.5.19.1.44
Retry K - number of timeouts before link is declared down.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

virtualUNIIntfType 3.1.1751.2.18.5.19.1.45
atm interface type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER user(1), network(2)  

virtualUNIUserAddress 3.1.1751.2.18.5.19.1.46
ATM User Address
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(7)  

virtualUNIUserAddrOrgScope 3.1.1751.2.18.5.19.1.47
ATM User Address Organizational scope
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER localNetwork(1), localNetworkPlusOne(2), localNetworkPlusTwo(3), siteMinusOne(4), intraSite(5), sitePlusOne(6), organizationMinusOne(7), intraOrganization(8), organizationPlusOne(9), communityMinusOne(10), intraCommunity(11), communityPlusOne(12), regional(13), interRegional(14), global(15)  

virtualUNISscopRxWndSz 3.1.1751.2.18.5.19.1.48
The receive window size for the SSCOP layer
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 8..256  

casConfig 3.1.1751.2.18.5.20
OBJECT IDENTIFIER    

casConfigTable 3.1.1751.2.18.5.20.1
Table for CAS trunk/line configuration.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CasConfigEntry

casConfigEntry 3.1.1751.2.18.5.20.1.1
Row definition for CAS trunk/line configuration.
Status: current Access: not-accessible
OBJECT-TYPE    
  CasConfigEntry  

casIfIndex 3.1.1751.2.18.5.20.1.1.1
The channel ID (slot/port/channel) in SSPPCCC format associated with the CAS trunk/line.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

casAdminStatus 3.1.1751.2.18.5.20.1.1.2
The administrative action: outOfService-take the CAS trunk/line out of service, inService-take the CAS trunk/line in service, delete-remove/deconfigure the CAS trunk/line.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2), delete(3)  

casOperStatus 3.1.1751.2.18.5.20.1.1.3
The operational status of the CAS trunk/line: outOfService-the CAS trunk/line is out of service, inService-the CAS trunk/line is in service.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2)  

casProtocolType 3.1.1751.2.18.5.20.1.1.4
The type of CAS protocol to be used. The protocol must match the one used on the other end of the trunk/line.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER wink-start(1), loop-start-network(2), loop-start-user(3), ground-start-network(4), ground-start-user(5), itu-t-r2(6)  

casDirection 3.1.1751.2.18.5.20.1.1.5
The direction of traffic flow on this CAS trunk/line.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER both(1), incoming(2), outgoing(3)  

casAddressingType 3.1.1751.2.18.5.20.1.1.6
The addressing type used for the CAS trunk/line. dtmf -- dual tone multifrequency r1-mf -- R1 multifrequency, r2-mf -- R2 multifrequency. Type of 're-mf' is valid only when casProtocolType is 'wink start', while 'r2-mf' is valid only when casProtocolType is 'itu-t r2' .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER dtmf(1), r1-mf(2), r2-mf(3)  

casBitPatternType 3.1.1751.2.18.5.20.1.1.7
The type of bit pattern used for supervisory signaling. The value is AB when SF framing is used, ABCD when ESF framing is used for DS1. In case of E1, the value is always ABCD.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ab(1), abcd(2)  

casGroupId 3.1.1751.2.18.5.20.1.1.8
The identifier to associate a group of CAS trunks/lines which have same reachability. When SG is disabled, it must be specified with a non-zero value. When SG is enabled, the value should be set to zero which indicate no routing performed based on the value.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

toneAnnceConfigTable 3.1.1751.2.18.5.21
Table for the Tone Announcement Interface
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ToneAnnceConfigEntry

toneAnnceConfigEntry 3.1.1751.2.18.5.21.1
Row definition for Tone Announcement interface
Status: current Access: not-accessible
OBJECT-TYPE    
  ToneAnnceConfigEntry  

toneAnnceIfIndex 3.1.1751.2.18.5.21.1.1
interface index (slot/port/channel) SSPPCCC
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

toneAnnceAdminStatus 3.1.1751.2.18.5.21.1.2
The administrative action: 'outOfService' means take the interface out of service 'inService' means take the interface in service 'delete' remove/deconfigure the interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2), delete(3)  

toneAnnceOperStatus 3.1.1751.2.18.5.21.1.3
The operational status of the interface: 'outOfService' means the interface is out of service 'inService' means the interface is in service
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2)  

gr303IntfConfig 3.1.1751.2.18.5.22
OBJECT IDENTIFIER    

gr303IntfConfigTable 3.1.1751.2.18.5.22.1
Table of GR303 interface configuration attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gr303IntfConfigEntry

gr303IntfConfigEntry 3.1.1751.2.18.5.22.1.1
Row definition for GR303 interface configuration table
Status: current Access: not-accessible
OBJECT-TYPE    
  Gr303IntfConfigEntry  

gr303IntfId 3.1.1751.2.18.5.22.1.1.1
Interface ID (SSPPCCC)
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

gr303TMCChannelId 3.1.1751.2.18.5.22.1.1.2
TMC-Channel Number. If TMC Channel is set to 0 there will be no TMC channel on the corresponding DS1. Generally the TMC channel should be specified on the one of the DS1's in a GR303 interface group and should be on DS0 no. 24
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..24  

gr303EOCChannelId 3.1.1751.2.18.5.22.1.1.3
EOC-Channel Number. If EOC Channel is set to 0 there will be no EOC channel on the corresponding DS1. Generally the TMC channel should be specified on the one of the DS1's in a GR303 interface group and should be on DS0 no. 12
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..24  

gr303IntfAdminStatus 3.1.1751.2.18.5.22.1.1.4
GR303 interface admin status
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2), delete(3)  

gr303IntfOperStatus 3.1.1751.2.18.5.22.1.1.5
GR303 interface operational status
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2)  

gr303Ds0ChanConfigTable 3.1.1751.2.18.5.22.2
Table of GR303 DS0 Channel configuration attriburtes
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gr303Ds0ChanConfigEntry

gr303Ds0ChanConfigEntry 3.1.1751.2.18.5.22.2.1
Row definition for GR303 DS0 Channel configuration table
Status: current Access: not-accessible
OBJECT-TYPE    
  Gr303Ds0ChanConfigEntry  

gr303Ds0ChanId 3.1.1751.2.18.5.22.2.1.1
GR303 DS0 Chan ID (SSPPCCC)
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

gr303Ds0ChanAdminStatus 3.1.1751.2.18.5.22.2.1.2
GR303 Ds0 Chan admin status
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2)  

gr303Ds0ChanOperStatus 3.1.1751.2.18.5.22.2.1.3
GR303 Ds0 Chan operational status
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2)  

gr303IgConfig 3.1.1751.2.18.26.1
OBJECT IDENTIFIER    

gr303IgConfigTable 3.1.1751.2.18.26.1.1
Table of GR303 group configuration
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gr303IgConfigEntry

gr303IgConfigEntry 3.1.1751.2.18.26.1.1.1
Row definition for GR303 group configuration
Status: current Access: not-accessible
OBJECT-TYPE    
  Gr303IgConfigEntry  

gr303IgId 3.1.1751.2.18.26.1.1.1.1
This is used as an index into GR303IG table which recognizes GR303 Interface Group
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..84  

gr303IgRowStatus 3.1.1751.2.18.26.1.1.1.2
GR303IG config entry row status
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

gr303IgAdminStatus 3.1.1751.2.18.26.1.1.1.3
Administrative status of the GR303IG
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER inService(1), outOfService(2)  

gr303IgPrimaryTMCChanIntfId 3.1.1751.2.18.26.1.1.1.4
Primary TMC channel Interface Id in SSPPCCC format
Status: current Access: read-write
OBJECT-TYPE    
  IntfIndex  

gr303IgPrimaryEOCChanIntfId 3.1.1751.2.18.26.1.1.1.5
Primary EOC channel Interface Id in SSPPCCC format
Status: current Access: read-write
OBJECT-TYPE    
  IntfIndex  

gr303IgBackupTMCChanIntfId 3.1.1751.2.18.26.1.1.1.6
Backup TMC channel Interface Id in SSPPCCC format
Status: current Access: read-write
OBJECT-TYPE    
  IntfIndex  

gr303IgBackupEOCChanIntfId 3.1.1751.2.18.26.1.1.1.7
Backup EOC channel Interface Id in SSPPCCC format
Status: current Access: read-write
OBJECT-TYPE    
  IntfIndex  

gr303IgPrimaryTMCStatus 3.1.1751.2.18.26.1.1.1.8
Primary TMC channel Status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER standby-OutOfService(1), standby-InService(2), active-OutOfService(3), active-InService(4)  

gr303IgPrimaryEOCStatus 3.1.1751.2.18.26.1.1.1.9
Primary EOC channel Status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER standby-OutOfService(1), standby-InService(2), active-OutOfService(3), active-InService(4)  

gr303IgBackupTMCStatus 3.1.1751.2.18.26.1.1.1.10
Backup TMC channel Status.Value null(5) Indicates that the Backup TMC has not been configured.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER standby-OutOfService(1), standby-InService(2), active-OutOfService(3), active-InService(4), null(5)  

gr303IgBackupEOCStatus 3.1.1751.2.18.26.1.1.1.11
Backup EOC channel Status.Value null(5) Indicates that the Backup EOC has not been configured.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER standby-OutOfService(1), standby-InService(2), active-OutOfService(3), active-InService(4), null(5)  

gr303IgTMCProtSwitchProvState 3.1.1751.2.18.26.1.1.1.12
Lock/Unlock the protection switch
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER pps-inhibit(1), pps-enable(2)  

gr303IgEOCProtSwitchProvState 3.1.1751.2.18.26.1.1.1.13
Lock/Unlock the protection switch
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER pps-inhibit(1), pps-enable(2)  

gr303IgTMCProtSwitchCommand 3.1.1751.2.18.26.1.1.1.14
User command to do path protection switch
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noAction(1), normalSwitchToBackup(2), normalSwitchToPrimary(3), forcedSwitchToBackup(4), forcedSwitchToPrimary(5)  

gr303IgEOCProtSwitchCommand 3.1.1751.2.18.26.1.1.1.15
User command to do path protection switch
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noAction(1), normalSwitchToBackup(2), normalSwitchToPrimary(3), forcedSwitchToBackup(4), forcedSwitchToPrimary(5)  

gr303IgLocalDigitalSwitchType 3.1.1751.2.18.26.1.1.1.16
LDS (IDT) type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER lucent-5ess(1), nortel-dms(2)  

gr303IgLocalDigitalSwitchVersion 3.1.1751.2.18.26.1.1.1.17
LDS (IDT)Version
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER lucent-5ess-version-1(1), nortel-dms-version-1(2)  

gr303IgIntfConfigTable 3.1.1751.2.18.26.1.2
Table of interface attributes in an GR303IG
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gr303IgIntfConfigEntry

gr303IgIntfConfigEntry 3.1.1751.2.18.26.1.2.1
Row definition for GR303 Access Arrangement Interface configuration
Status: current Access: not-accessible
OBJECT-TYPE    
  Gr303IgIntfConfigEntry  

gr303IntfIgId 3.1.1751.2.18.26.1.2.1.1
This is used as an index into GR303Ig table which recognizes GR303 Interface Group. This is used as a first index into this interface table.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..84  

gr303IgIntfId 3.1.1751.2.18.26.1.2.1.2
This is used as an index into IG interface table which recognizes GR303 Ig interfaces. This is used as a second index into this table
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..28  

gr303IgIntfPhysId 3.1.1751.2.18.26.1.2.1.3
Interface's Physical ID (SSPPCCC)
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

gr303IgIntfNetId 3.1.1751.2.18.26.1.2.1.4
gr303Ig Interface (DS1) Net Id assigned by the network
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

gr303IgIntfRowStatus 3.1.1751.2.18.26.1.2.1.5
GR303IG interface entry row status - row status can not be made active until all the values are set
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

gr303LapdConfigTable 3.1.1751.2.18.26.1.4
Table of LAPD attributes in an GR303IG
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gr303LapdConfigEntry

gr303LapdConfigEntry 3.1.1751.2.18.26.1.4.1
Row definition for LAPD attributes in a GR303IG
Status: current Access: not-accessible
OBJECT-TYPE    
  Gr303LapdConfigEntry  

gr303LapdIgId 3.1.1751.2.18.26.1.4.1.1
GR303IG Number index which recognizes GR303 Interface group
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..84  

gr303T200 3.1.1751.2.18.26.1.4.1.2
value of Lapd T200 timer in miliseconds in step size of 50 ms
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 100..350  

gr303T203 3.1.1751.2.18.26.1.4.1.3
value of Lapd T203 timer in seconds
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 10..300  

gr303N200 3.1.1751.2.18.26.1.4.1.4
Maximum number of retransmissions
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..10  

gr303K 3.1.1751.2.18.26.1.4.1.5
Maximum number of outstanding I frames - Lapd - window size.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..7  

gr303TMCConfigTable 3.1.1751.2.18.26.1.5
Table of Layer 3 attributes in an GR303IG
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gr303TMCConfigEntry

gr303TMCConfigEntry 3.1.1751.2.18.26.1.5.1
Row definition for GR303 Access Arrangement Layer3 parameters configuration
Status: current Access: not-accessible
OBJECT-TYPE    
  Gr303TMCConfigEntry  

gr303TMCIgId 3.1.1751.2.18.26.1.5.1.1
GR303IG Number index which recognizes GR303 Interface group
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..84  

gr303TMCT303 3.1.1751.2.18.26.1.5.1.2
value of TMC T303 timer in miliseconds with a step size of 500 ms
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 700..4700  

gr303TMCT396 3.1.1751.2.18.26.1.5.1.3
value of TMC T396 timer in miliseconds with a step size of 1000 ms
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 700..14700  

gr303IgStats 3.1.1751.2.18.27.1
OBJECT IDENTIFIER    

gr303IgStatsTable 3.1.1751.2.18.27.1.1
Table of GR303 GR303IG based stats attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gr303IgStatsEntry

gr303IgStatsEntry 3.1.1751.2.18.27.1.1.1
Row definition for GR303 GR303IG based stats
Status: current Access: not-accessible
OBJECT-TYPE    
  Gr303IgStatsEntry  

gr303IgStatsIgId 3.1.1751.2.18.27.1.1.1.1
This is used as an index into GR303 Ig table which recognizes GR303 Interface Group Interface group
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..84  

gr303IgStatsCurrentInCalls 3.1.1751.2.18.27.1.1.1.2
Total number of Currently established incoming calls
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

gr303IgStatsCurrentOutCalls 3.1.1751.2.18.27.1.1.1.3
Total number of Currently established outgoing calls
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

gr303IgStatsOutCallSuccessful 3.1.1751.2.18.27.1.1.1.4
Total number successful outgoing calls
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

gr303IgStatsOutCallFailed 3.1.1751.2.18.27.1.1.1.5
Total number of Failed outgoing calls
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

gr303IgStatsInCallSuccessful 3.1.1751.2.18.27.1.1.1.6
Total number successful incoming calls
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

gr303IgStatsInCallFailed 3.1.1751.2.18.27.1.1.1.7
Total number of Failed incoming calls
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

gr303IgStatsReset 3.1.1751.2.18.27.1.1.1.8
gr303Ig reset statistics button
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reset(1)  

atmPvcVccTable 3.1.1751.2.18.6.1
Table of PVC atm virtual channel connections
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmPvcVccEntry

atmPvcVccEntry 3.1.1751.2.18.6.1.1
Row definition of atm PVC VCC connections
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmPvcVccEntry  

atmPvcVccIfA 3.1.1751.2.18.6.1.1.1
Interface index for side A of an ATM-to-ATM PVC VCC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

atmPvcVccVpiA 3.1.1751.2.18.6.1.1.2
VPI value for side A of an ATM-to-ATM PVC VCC connection. Valid range is a number between 0 and 4095.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..4095  

atmPvcVccVciA 3.1.1751.2.18.6.1.1.3
VCI value for side A of an ATM-to-ATM PVC VCC connection. Valid range is a number between 0 and 65535.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..65535  

atmPvcVccIfB 3.1.1751.2.18.6.1.1.4
Interface index for side B of an ATM-to-ATM PVC VCC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

atmPvcVccVpiB 3.1.1751.2.18.6.1.1.5
VPI value for side B of an ATM-to-ATM PVC VCC connection. Valid range is a number between 0 and 4095.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..4095  

atmPvcVccVciB 3.1.1751.2.18.6.1.1.6
VCI value for side B of an ATM-to-ATM PVC VCC connection. Valid range is a number between 0 and 65535.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..65535  

atmPvcVccServiceTypeA2B 3.1.1751.2.18.6.1.1.7
service type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ubr(1), vbr-nrt2(2), vbr-nrt1(3), vbr-rt2(4), vbr-rt1(5), vbr-express(6), cbr4(7), cbr3(8), cbr2(9), cbr1(10), gfr2(11)  

atmPvcVccSarTypeA2B 3.1.1751.2.18.6.1.1.8
SAR type used in atm adaption
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER aal5(1), aal3-4(2), aal2(3), aal1(4), null(5)  

atmPvcVccPeakCellRateA2B 3.1.1751.2.18.6.1.1.10
peak cell rate - side A, in cell per second
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPvcVccSusCellRateA2B 3.1.1751.2.18.6.1.1.11
sustained rate - side A, in cell per second
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPvcVccMaxBurstSizeA2B 3.1.1751.2.18.6.1.1.12
maximum burst size - side A, in cells
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPvcVccServiceTypeB2A 3.1.1751.2.18.6.1.1.13
service type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ubr(1), vbr-nrt2(2), vbr-nrt1(3), vbr-rt2(4), vbr-rt1(5), vbr-express(6), cbr4(7), cbr3(8), cbr2(9), cbr1(10), gfr2(11)  

atmPvcVccSarTypeB2A 3.1.1751.2.18.6.1.1.14
sar type used in atm adaption
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER aal5(1), aal3-4(2), aal2(3), aal1(4), null(5)  

atmPvcVccPeakCellRateB2A 3.1.1751.2.18.6.1.1.16
peak rate - side B, in cell per second.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPvcVccSusCellRateB2A 3.1.1751.2.18.6.1.1.17
sustained rate - side B, in cell per second.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPvcVccMaxBurstSizeB2A 3.1.1751.2.18.6.1.1.18
maximum burst size - side B, in cells.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPvcVccType 3.1.1751.2.18.6.1.1.20
type of connection
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER nonsecured(1), secured(2)  

atmPvcVccFlow 3.1.1751.2.18.6.1.1.21
type of flow
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER duplex(1), simplexA2B(2), pointToMultipointA2B(3)  

atmPvcVccRowStatus 3.1.1751.2.18.6.1.1.22
row status
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

atmPvcVccFrwdErrCorrectionA2B 3.1.1751.2.18.6.1.1.23
Forward error correction scheme
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), eighthRate(2), quarterRate(3), halfRate(4), autoHiQ(5), auto(6), autoLoQ(7)  

atmPvcVccFrwdErrCorrectionB2A 3.1.1751.2.18.6.1.1.24
Forward error correction scheme
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), eighthRate(2), quarterRate(3), halfRate(4), autoHiQ(5), auto(6), autoLoQ(7)  

atmPvcVccConnectionStatus 3.1.1751.2.18.6.1.1.25
Indicates the current connections status. Active: All interfaces through which the connection is going are in service. Inactive: One of the end interfaces of the connection is not in service. The rest of the states apply to connections going through resource interfaces like DSP2 and FEC. These interfaces are dynamically allocated. InactiveA2B-B2A: Both the A2B and B2A resource interfaces are not in service. InactiveA2B: The A2B resource interface is not in service. InactiveB2A: The B2A resource interface is not in service. If an end interface and the resource interfaces are out of service, the status will be inactive because the end interfaces take priority.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER active(1), inactive(2), inactiveA2B-B2A(3), inactiveA2B(4), inactiveB2A(5)  

atmPvcVccOamStatus 3.1.1751.2.18.6.1.1.26
Indicates the OAM monitoring status of side A. The 5 possible states are: Unsupp: No monitoring enabled. End-Pt: A side is only an end point, therefore it will respond to AIS/RDI. Seg-Pt: A side is only a segment point, therefore it will only respond to maintenance OAM cells and not fault cells. End-Seg-Pt: A side is both an end point and a segment point. Intermediate-Pt: It will only generate AIS during local failure. For ATM-to-ATM connections the OAM status will be symmetric on both sides of the connection.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unsupp(1), end-Pt(2), seg-Pt(3), end-Seg-Pt(4), intermediate-Pt(5), intra-Segment-Pt(6)  

atmPvcVccDualHomed 3.1.1751.2.18.6.1.1.27
Does this PVC need a backup Dual homing PVC.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

atmPvcVccViA 3.1.1751.2.18.6.1.1.28
VI to associate the Egress part of the B2A connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1024  

atmPvcVccViB 3.1.1751.2.18.6.1.1.29
VI to associate the Egress part of the A2B connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1024  

atmPvcVccCnfrmTypeA2B 3.1.1751.2.18.6.1.1.30
The following is the description of this field This will be used in conjunction with the service type field to get the correct traffic behaviour. In the conformances the the 0 or 0plus1 refers to the clp bit in the cells. If 0plus1 is the bucket reference then the clp bit is ignored. If 0 is specified for the bucket then check only clp=0 cells. 1: Best Effort will try to send all cellsin a best effort way. This will follow the Aqueman Algorithm 2: one_bucket_notag_0plus1 will use 1 bucket i.e is the PCR(0+1) bucket and drop all cells in excess. 3: two_bucket_notag_0plus1_0plus1 uses 2 buckets. The 2 buckets are pcr(0+1) and scr(0+1). All cells conforming to both buckets will be passed through. The rest will be dropped. 4: two_bucket_notag_0plus1_0 uses 2 buckets. The 2 buckets are pcr(0+1) and scr(0) or pcr(0). Cells which conform to both buckets are passed through. The rest are dropped. 5: two_bucket_tag_0plus1_0 uses 2 buckets. The 2 buckets are pcr(0+1) and scr(0) or pcr(0). Cells which do not conform to the first bucket are dropped. Cells which do not conform to the 2nd bucket are tagged. 6: best_effort_tag. Tag all cells and then do a best effort.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER best-effort(1), one-bucket-notag-0plus1(2), two-bucket-notag-0plus1-0plus1(3), two-bucket-notag-0plus1-0(4), two-bucket-tag-0plus1-0(5), best-effort-tag(6)  

atmPvcVccCnfrmTypeB2A 3.1.1751.2.18.6.1.1.31
The following is the description of this field This will be used in conjunction with the service type field to get the correct traffic behaviour. In the conformances the the 0 or 0plus1 refers to the clp bit in the cells. If 0plus1 is the bucket reference then the clp bit is ignored. If 0 is specified for the bucket then check only clp=0 cells. 1: Best Effort will try to send all cellsin a best effort way. This will follow the Aqueman Algorithm 2: one_bucket_notag_0plus1 will use 1 bucket i.e is the PCR(0+1) bucket and drop all cells in excess. 3: two_bucket_notag_0plus1_0plus1 uses 2 buckets. The 2 buckets are pcr(0+1) and scr(0+1). All cells conforming to both buckets will be passed through. The rest will be dropped. 4: two_bucket_notag_0plus1_0 uses 2 buckets. The 2 buckets are pcr(0+1) and scr(0) or pcr(0). Cells which conform to both buckets are passed through. The rest are dropped. 5: two_bucket_tag_0plus1_0 uses 2 buckets. The 2 buckets are pcr(0+1) and scr(0) or pcr(0). Cells which do not conform to the first bucket are dropped. Cells which do not conform to the 2nd bucket are tagged. 6: best_effort_tag. Tag all cells and then do a best effort.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER best-effort(1), one-bucket-notag-0plus1(2), two-bucket-notag-0plus1-0plus1(3), two-bucket-notag-0plus1-0(4), two-bucket-tag-0plus1-0(5), best-effort-tag(6)  

atmPvcVccVUNIA 3.1.1751.2.18.6.1.1.32
VUNI to associate the Egress part of the B2A connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

atmPvcVccVUNIB 3.1.1751.2.18.6.1.1.33
VUNI to associate the Egress part of the A2B connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

atmPvcVccOamStatusB 3.1.1751.2.18.6.1.1.34
Indicates the Oam monitoring status of side B of an internal connection. Refer to ITU I.610 and Bellcore GR1248-CORE for definitions. The 6 possible states are: Unsupp: No OAM cell monitoring or generation enabled. All OAM flows are transparently passed through. End-Pt: Connection endPoint, segment flows are discarded. Seg-Pt: Segment endPoint. End-Seg-Pt: Connection endPoint that is also a segment endPoint. Intermediate-Pt: Connecting point, that is outside any segment. Generates only ete flows. Intra-Segment-Pt: Connecting point with a segment. Generates ete as well as segment flows.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unsupp(1), end-Pt(2), seg-Pt(3), end-Seg-Pt(4), intermediate-Pt(5), intra-Segment-Pt(6)  

atmPvcVccOAMConnEndPtStatusA 3.1.1751.2.18.6.1.1.35
Connection endpoint side A status. Valid only at connection endpoint.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ete-active(1), ete-ais-state(2), ete-rdi-state(3), ete-ais-rdi-state(4)  

atmPvcVccOAMConnEndPtStatusB 3.1.1751.2.18.6.1.1.36
Connection endpoint side B status. Valid only at connection endpoint.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ete-active(1), ete-ais-state(2), ete-rdi-state(3), ete-ais-rdi-state(4)  

atmPvcVccOAMConnSegEndPtStatusA 3.1.1751.2.18.6.1.1.37
Segment endpoint side A status. Valid only at segment endpoints.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER seg-active(1), seg-ais-state(2), seg-rdi-state(3), seg-ais-rdi-state(4)  

atmPvcVccOAMConnSegEndPtStatusB 3.1.1751.2.18.6.1.1.38
Segment endpoint side B status. Valid only at segment endpoints.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER seg-active(1), seg-ais-state(2), seg-rdi-state(3), seg-ais-rdi-state(4)  

atmPvcVccMfsA2B 3.1.1751.2.18.6.1.1.39
Maximum Frame Size for GFR traffic for A2B dir
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

atmPvcVccMfsB2A 3.1.1751.2.18.6.1.1.40
Maximum Frame Size for GFR traffic for B2A dir
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

atmPvcVccConnFailureCauseA 3.1.1751.2.18.6.1.1.41
connestion status reason code
Status: current Access: read-only
OBJECT-TYPE    
  AtmConnFailureCause  

atmPvcVccConnFailureCauseB 3.1.1751.2.18.6.1.1.42
connection status reason code
Status: current Access: read-only
OBJECT-TYPE    
  AtmConnFailureCause  

atmPvcVccTrafficShapingA2B 3.1.1751.2.18.6.1.1.43
Traffic Shaping Support in the A2B direction.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

atmPvcVccTrafficShapingB2A 3.1.1751.2.18.6.1.1.44
Traffic Shaping Support in the B2A direction.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

atmPvcVpcTable 3.1.1751.2.18.6.2
Table of PVC atm virtual path connections
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmPvcVpcEntry

atmPvcVpcEntry 3.1.1751.2.18.6.2.1
Row definition of atm connections
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmPvcVpcEntry  

atmPvcVpcIfA 3.1.1751.2.18.6.2.1.1
Interface index for side A of an ATM-to-ATM PVC VPC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

atmPvcVpcVpiA 3.1.1751.2.18.6.2.1.2
VPI value for side A of an ATM-to-ATM PVC VPC connection. Valid range is a number between 0 and 4095.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..4095  

atmPvcVpcIfB 3.1.1751.2.18.6.2.1.3
Interface index for side B of an ATM-to-ATM PVC VPC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

atmPvcVpcVpiB 3.1.1751.2.18.6.2.1.4
VPI value for side B of an ATM-to-ATM PVC VPC connection. Valid range is a number between 0 and 4095.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..4095  

atmPvcVpcServiceTypeA2B 3.1.1751.2.18.6.2.1.5
service type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ubr(1), vbr-nrt2(2), vbr-nrt1(3), vbr-rt2(4), vbr-rt1(5), vbr-express(6), cbr4(7), cbr3(8), cbr2(9), cbr1(10)  

atmPvcVpcSarTypeA2B 3.1.1751.2.18.6.2.1.6
SAR Type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER aal5(1), aal3-4(2), aal2(3), aal1(4), null(5)  

atmPvcVpcPeakCellRateA2B 3.1.1751.2.18.6.2.1.8
peak rate - side A, in cell per second.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPvcVpcSusCellRateA2B 3.1.1751.2.18.6.2.1.9
sustained rate - side A, in cell per second.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPvcVpcMaxBurstSizeA2B 3.1.1751.2.18.6.2.1.10
maximum burst size - side A, in cell per second.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPvcVpcServiceTypeB2A 3.1.1751.2.18.6.2.1.11
service type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ubr(1), vbr-nrt2(2), vbr-nrt1(3), vbr-rt2(4), vbr-rt1(5), vbr-express(6), cbr4(7), cbr3(8), cbr2(9), cbr1(10)  

atmPvcVpcSarTypeB2A 3.1.1751.2.18.6.2.1.12
SAR Type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER aal5(1), aal3-4(2), aal2(3), aal1(4), null(5)  

atmPvcVpcPeakCellRateB2A 3.1.1751.2.18.6.2.1.14
peak rate - side B, in cell per second.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPvcVpcSusCellRateB2A 3.1.1751.2.18.6.2.1.15
sustained rate - side B, in cell per second.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPvcVpcMaxBurstSizeB2A 3.1.1751.2.18.6.2.1.16
maximum burst size - side B, in cell per second.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmPvcVpcType 3.1.1751.2.18.6.2.1.17
security feature type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER nonsecured(1), secured(2)  

atmPvcVpcFlow 3.1.1751.2.18.6.2.1.18
flow type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER duplex(1), simplexA2B(2), pointToMultipointA2B(3)  

atmPvcVpcRowStatus 3.1.1751.2.18.6.2.1.19
row status
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

atmPvcVpcConnectionStatus 3.1.1751.2.18.6.2.1.20
Indicates the current connections status. Active: All interfaces through which the connection is going are in service. Inactive: One of the end interfaces of the connection is not in service. The rest of the states apply to connections going through resource interfaces like DSP2 and FEC. These interfaces are dynamically allocated. InactiveA2B-B2A: Both the A2B and B2A resource interfaces are not in service. InactiveA2B: The A2B resource interface is not in service. InactiveB2A: The B2A resource interface is not in service. If an end interface and the resource interfaces are out of service, the status will be inactive because the end interfaces take priority.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER active(1), inactive(2), inactiveA2B-B2A(3), inactiveA2B(4), inactiveB2A(5)  

atmPvcVpcOamStatus 3.1.1751.2.18.6.2.1.21
Indicates the OAM monitoring status of side A. The 5 possible states are: Unsupp: No monitoring enabled. End-Pt: A side is only an end point, therefore it will respond to AIS/RDI. Seg-Pt: A side is only a segment point, therefore it will only respond to maintenance OAM cells and not fault cells. End-Seg-Pt: A side is both an end point and a segment point. Intermediate-Pt: It will only generate AIS during local failure. For ATM-to-ATM connections the OAM status will be symmetric on both sides of the connection.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unsupp(1), end-Pt(2), seg-Pt(3), end-Seg-Pt(4), intermediate-Pt(5), intra-Segment-Pt(6)  

atmPvcVpcDualHomed 3.1.1751.2.18.6.2.1.22
Does this PVC need a backup Dual homing PVC.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

atmPvcVpcViA 3.1.1751.2.18.6.2.1.23
VI to associate the Egress part of the B2A connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1024  

atmPvcVpcViB 3.1.1751.2.18.6.2.1.24
VI to associate the Egress part of the A2B connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1024  

atmPvcVpcCnfrmTypeA2B 3.1.1751.2.18.6.2.1.25
The following is the description of this field This will be used in conjunction with the service type field to get the correct traffic behaviour. In the conformances the the 0 or 0plus1 refers to the clp bit in the cells. If 0plus1 is the bucket reference then the clp bit is ignored. If 0 is specified for the bucket then check only clp=0 cells. 1: Best Effort will try to send all cellsin a best effort way. This will follow the Aqueman Algorithm 2: one-bucket-notag-0plus1 will use 1 bucket i.e is the PCR(0+1) bucket and drop all cells in excess. 3: two-bucket-notag-0plus1-0plus1 uses 2 buckets. The 2 buckets are pcr(0+1) and scr(0+1). All cells conforming to both buckets will be passed through. The rest will be dropped. 4: two-bucket-notag-0plus1-0 uses 2 buckets. The 2 buckets are pcr(0+1) and scr(0) or pcr(0). Cells which conform to both buckets are passed through. The rest are dropped. 5: two-bucket-tag-0plus1-0 uses 2 buckets. The 2 buckets are pcr(0+1) and scr(0) or pcr(0). Cells which do not conform to the first bucket are dropped. Cells which do not conform to the 2nd bucket are tagged. 6: best-effort-tag. Tag all cells and then do a best effort.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER best-effort(1), one-bucket-notag-0plus1(2), two-bucket-notag-0plus1-0plus1(3), two-bucket-notag-0plus1-0(4), two-bucket-tag-0plus1-0(5), best-effort-tag(6)  

atmPvcVpcCnfrmTypeB2A 3.1.1751.2.18.6.2.1.26
The following is the description of this field This will be used in conjunction with the service type field to get the correct traffic behaviour. In the conformances the the 0 or 0plus1 refers to the clp bit in the cells. If 0plus1 is the bucket reference then the clp bit is ignored. If 0 is specified for the bucket then check only clp=0 cells. 1: Best Effort will try to send all cellsin a best effort way. This will follow the Aqueman Algorithm 2: one-bucket-notag-0plus1 will use 1 bucket i.e is the PCR(0+1) bucket and drop all cells in excess. 3: two-bucket-notag-0plus1-0plus1 uses 2 buckets. The 2 buckets are pcr(0+1) and scr(0+1). All cells conforming to both buckets will be passed through. The rest will be dropped. 4: two-bucket-notag-0plus1-0 uses 2 buckets. The 2 buckets are pcr(0+1) and scr(0) or pcr(0). Cells which conform to both buckets are passed through. The rest are dropped. 5: two-bucket-tag-0plus1-0 uses 2 buckets. The 2 buckets are pcr(0+1) and scr(0) or pcr(0). Cells which do not conform to the first bucket are dropped. Cells which do not conform to the 2nd bucket are tagged. 6: best-effort-tag. Tag all cells and then do a best effort.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER best-effort(1), one-bucket-notag-0plus1(2), two-bucket-notag-0plus1-0plus1(3), two-bucket-notag-0plus1-0(4), two-bucket-tag-0plus1-0(5), best-effort-tag(6)  

atmPvcVpcVUNIA 3.1.1751.2.18.6.2.1.27
VUNI Id to associate the Egress part of the B2A connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

atmPvcVpcVUNIB 3.1.1751.2.18.6.2.1.28
VUNI Id to associate the Egress part of the A2B connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

atmPvcVpcOamStatusB 3.1.1751.2.18.6.2.1.29
Indicates the Oam monitoring status of side B of an internal connection. Refer to ITU I.610 and Bellcore GR1248-CORE for definitions. The 6 possible states are: Unsupp: No OAM cell monitoring or generation enabled. All OAM flows are transparently passed through. End-Pt: Connection endPoint, segment flows are discarded. Seg-Pt: Segment endPoint. End-Seg-Pt: Connection endPoint that is also a segment endPoint. Intermediate-Pt: Connecting point, that is outside any segment. Generates only ete flows. Intra-Segment-Pt: Connecting point with a segment. Generates ete as well as segment flows.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unsupp(1), end-Pt(2), seg-Pt(3), end-Seg-Pt(4), intermediate-Pt(5), intra-Segment-Pt(6)  

atmPvcVpcOAMConnEndPtStatusA 3.1.1751.2.18.6.2.1.30
Connection endpoint side A status. Valid only at connection endpoint.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ete-active(1), ete-ais-state(2), ete-rdi-state(3), ete-ais-rdi-state(4)  

atmPvcVpcOAMConnEndPtStatusB 3.1.1751.2.18.6.2.1.31
Connection endpoint side B status. Valid only at connection endpoint.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ete-active(1), ete-ais-state(2), ete-rdi-state(3), ete-ais-rdi-state(4)  

atmPvcVpcOAMConnSegEndPtStatusA 3.1.1751.2.18.6.2.1.32
Segment endpoint side A status. Valid only at segment/connection endpoints.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER seg-active(1), seg-ais-state(2), seg-rdi-state(3), seg-ais-rdi-state(4)  

atmPvcVpcOAMConnSegEndPtStatusB 3.1.1751.2.18.6.2.1.33
Segment endpoint side B status. Valid only at segment/connection endpoints.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER seg-active(1), seg-ais-state(2), seg-rdi-state(3), seg-ais-rdi-state(4)  

atmPvcVpcConnFailureCauseA 3.1.1751.2.18.6.2.1.34
connestion status reason code
Status: current Access: read-only
OBJECT-TYPE    
  AtmConnFailureCause  

atmPvcVpcConnFailureCauseB 3.1.1751.2.18.6.2.1.35
connection status reason code
Status: current Access: read-only
OBJECT-TYPE    
  AtmConnFailureCause  

atmPvcVpcTrafficShapingA2B 3.1.1751.2.18.6.2.1.36
Traffic Shaping Support in the A2B direction.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

atmPvcVpcTrafficShapingB2A 3.1.1751.2.18.6.2.1.37
Traffic Shaping Support in the B2A direction.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

atmSvcVccTable 3.1.1751.2.18.6.3
Table of atm connections
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmSvcVccEntry

atmSvcVccEntry 3.1.1751.2.18.6.3.1
Row definition of atm connections
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmSvcVccEntry  

atmSvcVccIfA 3.1.1751.2.18.6.3.1.1
interface index (slot/port/channel) SSPPCCC
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

atmSvcVccVpiA 3.1.1751.2.18.6.3.1.2
atm path identifier - side A
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..4095  

atmSvcVccVciA 3.1.1751.2.18.6.3.1.3
atm channel identifier - side A
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..65535  

atmSvcVccIfB 3.1.1751.2.18.6.3.1.4
interface index (slot/port/channel) SSPPCCC
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

atmSvcVccVpiB 3.1.1751.2.18.6.3.1.5
atm path identifier - side B
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..4095  

atmSvcVccVciB 3.1.1751.2.18.6.3.1.6
atm channel identifier - side B
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..65535  

atmSvcVccServiceTypeA2B 3.1.1751.2.18.6.3.1.7
service type
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ubr(1), vbr-nrt2(2), vbr-nrt1(3), vbr-rt2(4), vbr-rt1(5), vbr-express(6), cbr4(7), cbr3(8), cbr2(9), cbr1(10)  

atmSvcVccSarTypeA2B 3.1.1751.2.18.6.3.1.8
sar type - A to B direction
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER aal5(1), aal3-4(2), aal2(3), aal1(4), null(5)  

atmSvcVccPeakCellRateA2B 3.1.1751.2.18.6.3.1.10
peak rate - side A
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSvcVccSusCellRateA2B 3.1.1751.2.18.6.3.1.11
sustained rate - side A
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSvcVccMaxBurstSizeA2B 3.1.1751.2.18.6.3.1.12
maximum burst size - side A
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSvcVccServiceTypeB2A 3.1.1751.2.18.6.3.1.13
service type
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ubr(1), vbr-nrt2(2), vbr-nrt1(3), vbr-rt2(4), vbr-rt1(5), vbr-express(6), cbr4(7), cbr3(8), cbr2(9), cbr1(10)  

atmSvcVccSarTypeB2A 3.1.1751.2.18.6.3.1.14
sar type - B to A direction
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER aal5(1), aal3-4(2), aal2(3), aal1(4), null(5)  

atmSvcVccPeakCellRateB2A 3.1.1751.2.18.6.3.1.16
peak rate - side B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSvcVccSusCellRateB2A 3.1.1751.2.18.6.3.1.17
sustained rate - side B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSvcVccMaxBurstSizeB2A 3.1.1751.2.18.6.3.1.18
maximum burst size - side B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSvcVccFlow 3.1.1751.2.18.6.3.1.19
flow type
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER duplex(1), pointToMultipoint(2)  

atmSvcVccType 3.1.1751.2.18.6.3.1.20
type of connection
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER nonsecured(1), secured(2)  

atmSvcVccConnectionStatus 3.1.1751.2.18.6.3.1.21
Indicates the current connections status. Active: All interfaces through which the connection is going are in service. Inactive: One of the end interfaces of the connection is not in service. The rest of the states apply to connections going through resource interfaces like DSP2 and FEC. These interfaces are dynamically allocated. InactiveA2B-B2A: Both the A2B and B2A resource interfaces are not in service. InactiveA2B: The A2B resource interface is not in service. InactiveB2A: The B2A resource interface is not in service. If an end interface and the resource interfaces are out of service, the status will be inactive because the end interfaces take priority.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER active(1), inactive(2), inactiveA2B-B2A(3), inactiveA2B(4), inactiveB2A(5)  

atmSvcVccViA 3.1.1751.2.18.6.3.1.22
VI to associate the Egress part of the B2A connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1024  

atmSvcVccViB 3.1.1751.2.18.6.3.1.23
VI to associate the Egress part of the A2B connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1024  

atmSvcVccCnfrmTypeA2B 3.1.1751.2.18.6.3.1.24
The following is the description of this field This will be used in conjunction with the service type field to get the correct traffic behaviour. In the conformances the the 0 or 0plus1 refers to the clp bit in the cells. If 0plus1 is the bucket reference then the clp bit is ignored. If 0 is specified for the bucket then check only clp=0 cells. 1: Best Effort will try to send all cellsin a best effort way. This will follow the Aqueman Algorithm 2: one-bucket-notag-0plus1 will use 1 bucket i.e is the PCR(0+1) bucket and drop all cells in excess. 3: two-bucket-notag-0plus1-0plus1 uses 2 buckets. The 2 buckets are pcr(0+1) and scr(0+1). All cells conforming to both buckets will be passed through. The rest will be dropped. 4: two-bucket-notag-0plus1-0 uses 2 buckets. The 2 buckets are pcr(0+1) and scr(0) or pcr(0). Cells which conform to both buckets are passed through. The rest are dropped. 5: two-bucket-tag-0plus1-0 uses 2 buckets. The 2 buckets are pcr(0+1) and scr(0) or pcr(0). Cells which do not conform to the first bucket are dropped. Cells which do not conform to the 2nd bucket are tagged. 6: best-effort-tag. Tag all cells and then do a best effort.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER best-effort(1), one-bucket-notag-0plus1(2), two-bucket-notag-0plus1-0plus1(3), two-bucket-notag-0plus1-0(4), two-bucket-tag-0plus1-0(5), best-effort-tag(6)  

atmSvcVccCnfrmTypeB2A 3.1.1751.2.18.6.3.1.25
The following is the description of this field This will be used in conjunction with the service type field to get the correct traffic behaviour. In the conformances the the 0 or 0plus1 refers to the clp bit in the cells. If 0plus1 is the bucket reference then the clp bit is ignored. If 0 is specified for the bucket then check only clp=0 cells. 1: Best Effort will try to send all cellsin a best effort way. This will follow the Aqueman Algorithm 2: one-bucket-notag-0plus1 will use 1 bucket i.e is the PCR(0+1) bucket and drop all cells in excess. 3: two-bucket-notag-0plus1-0plus1 uses 2 buckets. The 2 buckets are pcr(0+1) and scr(0+1). All cells conforming to both buckets will be passed through. The rest will be dropped. 4: two-bucket-notag-0plus1-0 uses 2 buckets. The 2 buckets are pcr(0+1) and scr(0) or pcr(0). Cells which conform to both buckets are passed through. The rest are dropped. 5: two-bucket-tag-0plus1-0 uses 2 buckets. The 2 buckets are pcr(0+1) and scr(0) or pcr(0). Cells which do not conform to the first bucket are dropped. Cells which do not conform to the 2nd bucket are tagged. 6: best-effort-tag. Tag all cells and then do a best effort.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER best-effort(1), one-bucket-notag-0plus1(2), two-bucket-notag-0plus1-0plus1(3), two-bucket-notag-0plus1-0(4), two-bucket-tag-0plus1-0(5), best-effort-tag(6)  

atmSvcVccVUNIA 3.1.1751.2.18.6.3.1.26
VUNI to associate the Egress part of the B2A connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

atmSvcVccVUNIB 3.1.1751.2.18.6.3.1.27
VUNI to associate the Egress part of the A2B connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

atmSvcVccTrafficShapingA2B 3.1.1751.2.18.6.3.1.28
Traffic Shaping Support in the A2B direction.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

atmSvcVccTrafficShapingB2A 3.1.1751.2.18.6.3.1.29
Traffic Shaping Support in the B2A direction.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

ipAtmAppPvcVccTable 3.1.1751.2.18.6.4
Table about in-band management atm connection entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IpAtmAppPvcVccEntry

ipAtmAppPvcVccEntry 3.1.1751.2.18.6.4.1
Row definition of in-band management atm connection attribution.
Status: current Access: not-accessible
OBJECT-TYPE    
  IpAtmAppPvcVccEntry  

ipAtmAppPvcVccDestAddrA 3.1.1751.2.18.6.4.1.1
Destination IP address of an in-band management- atm connection. Value is and IP address.
Status: current Access: not-accessible
OBJECT-TYPE    
  IpAddress  

ipAtmAppPvcVccSubnetMaskA 3.1.1751.2.18.6.4.1.2
The subnet mask of the destination IP address. Value is an IP address.
Status: current Access: not-accessible
OBJECT-TYPE    
  IpAddress  

ipAtmAppPvcVccIfB 3.1.1751.2.18.6.4.1.3
Interface index for side B, the atm side, of an in-band management-atm connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

ipAtmAppPvcVccVpiB 3.1.1751.2.18.6.4.1.4
VPI value for side B, the atm side, of an in-band management-atm connection. Valid range is a number between 0 and 4095.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..4095  

ipAtmAppPvcVccVciB 3.1.1751.2.18.6.4.1.5
VCI value for side B, the atm side, of an in-band management-atm connection. Valid range is a number between 0 and 65535.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..65535  

ipAtmAppPvcVccServiceTypeA2B 3.1.1751.2.18.6.4.1.6
Service type from side A to B
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ubr(1), vbr-express(2)  

ipAtmAppPvcVccServiceTypeB2A 3.1.1751.2.18.6.4.1.7
Service type from side B to A
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ubr(1), vbr-express(2), gfr2(3)  

ipAtmAppPvcVccPeakCellRateB2A 3.1.1751.2.18.6.4.1.8
peak rate - side B
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

ipAtmAppPvcVccSusCellRateB2A 3.1.1751.2.18.6.4.1.9
sustained rate - side B
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

ipAtmAppPvcVccMaxBurstSizeB2A 3.1.1751.2.18.6.4.1.10
maximum burst size - side B
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

ipAtmAppPvcVccType 3.1.1751.2.18.6.4.1.11
Indicated in-band management atm connection type.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER primary(0), backup(1)  

ipAtmAppPvcVccRowStatus 3.1.1751.2.18.6.4.1.12
row status
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

ipAtmAppPvcVccConnectionStatus 3.1.1751.2.18.6.4.1.13
Indicates the current connections status. Active: All interfaces through which the connection is going are in service. Inactive: One of the end interfaces of the connection is not in service. The rest of the states apply to connections going through resource interfaces like DSP2 and FEC. These interfaces are dynamically allocated. InactiveA2B-B2A: Both the A2B and B2A resource interfaces are not in service. InactiveA2B: The A2B resource interface is not in service. InactiveB2A: The B2A resource interface is not in service. If an end interface and the resource interfaces are out of service, the status will be inactive because the end interfaces take priority.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER active(1), inactive(2), inactiveA2B-B2A(3), inactiveA2B(4), inactiveB2A(5)  

ipAtmAppPvcVccDualHomed 3.1.1751.2.18.6.4.1.14
Does this PVC need a backup Dual homing PVC.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

ipAtmAppPvcVccViB 3.1.1751.2.18.6.4.1.15
VI to associate the Egress part of the A2B connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1024  

ipAtmAppPvcVccCnfrmTypeB2A 3.1.1751.2.18.6.4.1.16
The following is the description of this field This will be used in conjunction with the service type field to get the correct traffic behaviour. In the conformances the the 0 or 0plus1 refers to the clp bit in the cells. If 0plus1 is the bucket reference then the clp bit is ignored. If 0 is specified for the bucket then check only clp=0 cells. 1: Best Effort will try to send all cellsin a best effort way. This will follow the Aqueman Algorithm 2: one-bucket-notag-0plus1 will use 1 bucket i.e is the PCR(0+1) bucket and drop all cells in excess. 3: two-bucket-notag-0plus1-0plus1 uses 2 buckets. The 2 buckets are pcr(0+1) and scr(0+1). All cells conforming to both buckets will be passed through. The rest will be dropped. 4: two-bucket-notag-0plus1-0 uses 2 buckets. The 2 buckets are pcr(0+1) and scr(0) or pcr(0). Cells which conform to both buckets are passed through. The rest are dropped. 5: two-bucket-tag-0plus1-0 uses 2 buckets. The 2 buckets are pcr(0+1) and scr(0) or pcr(0). Cells which do not conform to the first bucket are dropped. Cells which do not conform to the 2nd bucket are tagged. 6: best-effort-tag. Tag all cells and then do a best effort.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER best-effort(1), one-bucket-notag-0plus1(2), two-bucket-notag-0plus1-0plus1(3), two-bucket-notag-0plus1-0(4), two-bucket-tag-0plus1-0(5), best-effort-tag(6)  

ipAtmAppPvcVccVUNIB 3.1.1751.2.18.6.4.1.17
VUNI to associate the Egress part of the A2B connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

ipAtmAppPvcVccMfsB2A 3.1.1751.2.18.6.4.1.18
Maximum Frame Size for GFR traffic
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ipAtmAppPvcVccConnFailureCauseB 3.1.1751.2.18.6.4.1.19
connection status reason code
Status: current Access: read-only
OBJECT-TYPE    
  AtmConnFailureCause  

ipAtmAppPvcVccTrafficShapingA2B 3.1.1751.2.18.6.4.1.20
Traffic Shaping Support in the A2B direction.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

ipAtmAppPvcVccOamStatus 3.1.1751.2.18.6.4.1.21
Indicates the OAM monitoring status. The 3 possible states are: Unsupp: No monitoring enabled. End-Pt: A side is only an end point, therefore it will respond to AIS/RDI. End-Seg-Pt: Connection endPoint that is also a segment endPoint.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unsupp(1), end-Pt(2), end-Seg-Pt(3)  

ipAtmAppSvcVccTable 3.1.1751.2.18.6.5
Table of SVC VCC connection entries
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IpAtmAppSvcVccEntry

ipAtmAppSvcVccEntry 3.1.1751.2.18.6.5.1
Row definition of SVC VCC connection attribution.
Status: current Access: not-accessible
OBJECT-TYPE    
  IpAtmAppSvcVccEntry  

ipAtmAppSvcVccDestAddrA 3.1.1751.2.18.6.5.1.1
Destination IP address,value is IP address.
Status: current Access: not-accessible
OBJECT-TYPE    
  IpAddress  

ipAtmAppSvcVccSubnetMaskA 3.1.1751.2.18.6.5.1.2
The subnet mask of the destination IP address. Value is an IP address.
Status: current Access: not-accessible
OBJECT-TYPE    
  IpAddress  

ipAtmAppSvcVccIfB 3.1.1751.2.18.6.5.1.3
interface index (slot/port/channel) SSPPCCC
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

ipAtmAppSvcVccVpiB 3.1.1751.2.18.6.5.1.4
atm path identifier - side B
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..4095  

ipAtmAppSvcVccVciB 3.1.1751.2.18.6.5.1.5
atm channel identifier - side B
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..65535  

ipAtmAppSvcVccServiceTypeA2B 3.1.1751.2.18.6.5.1.6
Service type from side A to B.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ubr(1), vbr-express(2)  

ipAtmAppSvcVccServiceTypeB2A 3.1.1751.2.18.6.5.1.7
Service type from side B to A.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ubr(1), vbr-express(2)  

ipAtmAppSvcVccPeakCellRateB2A 3.1.1751.2.18.6.5.1.8
peak rate - side B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAtmAppSvcVccSusCellRateB2A 3.1.1751.2.18.6.5.1.9
sustained rate - side B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAtmAppSvcVccMaxBurstSizeB2A 3.1.1751.2.18.6.5.1.10
maximum burst size - side B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAtmAppSvcVccType 3.1.1751.2.18.6.5.1.11
Type of using SVC VCC connection.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER primary(0), backup(1)  

ipAtmAppSvcVccConnectionStatus 3.1.1751.2.18.6.5.1.12
Indicates the current connections status. Active: All interfaces through which the connection is going are in service. Inactive: One of the end interfaces of the connection is not in service. The rest of the states apply to connections going through resource interfaces like DSP2 and FEC. These interfaces are dynamically allocated. InactiveA2B-B2A: Both the A2B and B2A resource interfaces are not in service. InactiveA2B: The A2B resource interface is not in service. InactiveB2A: The B2A resource interface is not in service. If an end interface and the resource interfaces are out of service, the status will be inactive because the end interfaces take priority.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER active(1), inactive(2), inactiveA2B-B2A(3), inactiveA2B(4), inactiveB2A(5)  

ipAtmAppSvcVccViB 3.1.1751.2.18.6.5.1.13
VI to associate the Egress part of the A2B connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1024  

ipAtmAppSvcVccCnfrmTypeB2A 3.1.1751.2.18.6.5.1.14
The following is the description of this field This will be used in conjunction with the service type field to get the correct traffic behaviour. In the conformances the the 0 or 0plus1 refers to the clp bit in the cells. If 0plus1 is the bucket reference then the clp bit is ignored. If 0 is specified for the bucket then check only clp=0 cells. 1: Best Effort will try to send all cellsin a best effort way. This will follow the Aqueman Algorithm 2: one-bucket-notag-0plus1 will use 1 bucket i.e is the PCR(0+1) bucket and drop all cells in excess. 3: two-bucket-notag-0plus1-0plus1 uses 2 buckets. The 2 buckets are pcr(0+1) and scr(0+1). All cells conforming to both buckets will be passed through. The rest will be dropped. 4: two-bucket-notag-0plus1-0 uses 2 buckets. The 2 buckets are pcr(0+1) and scr(0) or pcr(0). Cells which conform to both buckets are passed through. The rest are dropped. 5: two-bucket-tag-0plus1-0 uses 2 buckets. The 2 buckets are pcr(0+1) and scr(0) or pcr(0). Cells which do not conform to the first bucket are dropped. Cells which do not conform to the 2nd bucket are tagged. 6: best-effort-tag. Tag all cells and then do a best effort.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER best-effort(1), one-bucket-notag-0plus1(2), two-bucket-notag-0plus1-0plus1(3), two-bucket-notag-0plus1-0(4), two-bucket-tag-0plus1-0(5), best-effort-tag(6)  

ipAtmAppSvcVccVUNIB 3.1.1751.2.18.6.5.1.15
VUNI to associate the Egress part of the A2B connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

ipAtmAppSvcVccTrafficShapingA2B 3.1.1751.2.18.6.5.1.16
Traffic Shaping Support in the A2B direction.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

cirEmAtmPvcVccTable 3.1.1751.2.18.6.6
Table of Circuit Emulation to ATM VCCs
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CirEmAtmPvcVccEntry

cirEmAtmPvcVccEntry 3.1.1751.2.18.6.6.1
Row definition of circuit emulation to atm connections.
Status: current Access: not-accessible
OBJECT-TYPE    
  CirEmAtmPvcVccEntry  

cirEmAtmPvcVccIfA 3.1.1751.2.18.6.6.1.1
Interface index for side A, the circuit emulation side, of a circuit emulation-atm PVC VCC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

cirEmAtmPvcVccIfB 3.1.1751.2.18.6.6.1.2
Interface index for side B, the atm side, of a circuit emulation-atm PVC VCC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

cirEmAtmPvcVccVpiB 3.1.1751.2.18.6.6.1.3
VPI value for side B, the atm side, of a circuit emulation-atm PVC VCC connection. Valid range is a number between 0 and 4095.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..4095  

cirEmAtmPvcVccVciB 3.1.1751.2.18.6.6.1.4
VCI value for side B, the atm side, of a circuit emulation-atm PVC VCC connection. Valid range is a number between 0 and 65535.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..65535  

cirEmAtmPvcVccServiceType 3.1.1751.2.18.6.6.1.5
service type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER cbr-1(1), cbr-2(2), cbr-3(3), cbr-4(4)  

cirEmAtmPvcVccVoiceCompressionA2B 3.1.1751.2.18.6.6.1.6
Voice Compression Algorithm
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), g726-16k(2), g726-24k(3), g726-32k(4), g726-40k(5), g729a-8k(6)  

cirEmAtmPvcVccSilenceDetectionA2B 3.1.1751.2.18.6.6.1.7
silence detection off/on
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

cirEmAtmPvcVccEchoCancellationA2B 3.1.1751.2.18.6.6.1.8
Echo Cancellation Algorithm
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), g165-nearEnd(2), g168(3)  

cirEmAtmPvcVccFlow 3.1.1751.2.18.6.6.1.9
Flow Type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER duplex(1), simplexA2B(2), simplexB2A(3), pointToMultipointA2B(4), pointToMultipointB2A(5)  

cirEmAtmPvcVccRowStatus 3.1.1751.2.18.6.6.1.10
row status
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

cirEmAtmPvcVccCngToneDetectionA2B 3.1.1751.2.18.6.6.1.11
Calling Tone Detection Algorithm, one of the enum value, g726-32k(3) is obsoleted on 01Mar99 such that user would not be able to configure CE-ATM.Fax Relay is to allow detection of fax Calling Tones. In faxRelay Mode only Fax calling tone is detected . In fxRlyMdmBypass faxRelay is detected and Modem is done in bypass mode
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), bypass(2), g726-32k(3), faxRelay(4), fxRlyMdmBypass(5)  

cirEmAtmPvcVccCodingTranslationA2B 3.1.1751.2.18.6.6.1.12
Coding rule translation type.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), muLaw2muLaw(2), aLaw2aLaw(3), muLaw2aLaw(4), aLaw2muLaw(5)  

cirEmAtmPvcVccVoiceCompressionB2A 3.1.1751.2.18.6.6.1.13
Voice Compression Algorithm
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), g726-16k(2), g726-24k(3), g726-32k(4), g726-40k(5), g729a-8k(6)  

cirEmAtmPvcVccSilenceDetectionB2A 3.1.1751.2.18.6.6.1.14
silence detection off/on
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

cirEmAtmPvcVccEchoCancellationB2A 3.1.1751.2.18.6.6.1.15
Echo Cancellation Algorithm
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), g165-nearEnd(2), g168(3)  

cirEmAtmPvcVccCngToneDetectionB2A 3.1.1751.2.18.6.6.1.16
Calling Tone Detection Algorithm, one of the enum value, g726-32k(3) is obsoleted on 01Mar99 such that user would not be able to configure CE-ATM.Fax Relay is to allow detection of fax Calling Tones. In faxRelay Mode only Fax calling tone is detected . In fxRlyMdmBypass faxRelay is detected and Modem is done in bypass mode
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), bypass(2), g726-32k(3), faxRelay(4), fxRlyMdmBypass(5)  

cirEmAtmPvcVccCodingTranslationB2A 3.1.1751.2.18.6.6.1.17
Coding rule translation type.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), muLaw2muLaw(2), aLaw2aLaw(3), muLaw2aLaw(4), aLaw2muLaw(5)  

cirEmAtmPvcVccSarTypeB 3.1.1751.2.18.6.6.1.18
This field will only be used when selecting voice compression, in other cases it will be set to aal1.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER aal2(3), aal1(4), aal2Std(5)  

cirEmAtmPvcVccConnectionStatus 3.1.1751.2.18.6.6.1.19
Indicates the current connections status. Active: All interfaces through which the connection is going are in service. Inactive: One of the end interfaces of the connection is not in service. The rest of the states apply to connections going through resource interfaces like DSP2 and FEC. These interfaces are dynamically allocated. InactiveA2B-B2A: Both the A2B and B2A resource interfaces are not in service. InactiveA2B: The A2B resource interface is not in service. InactiveB2A: The B2A resource interface is not in service. If an end interface and the resource interfaces are out of service, the status will be inactive because the end interfaces take priority.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER active(1), inactive(2), inactiveA2B-B2A(3), inactiveA2B(4), inactiveB2A(5)  

cirEmAtmPvcVccDualHomed 3.1.1751.2.18.6.6.1.20
Does this PVC need a backup Dual homing PVC.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

cirEmAtmPvcVccOamStatus 3.1.1751.2.18.6.6.1.21
Indicates the OAM monitoring status of side A. The 2 possible states are: Unsupp: No monitoring enabled. End-Pt: A side is only an end point, therefore it will respond to AIS/RDI.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unsupp(1), end-Pt(2), end-Seg-Pt(3)  

cirEmAtmPvcVccViB 3.1.1751.2.18.6.6.1.22
VI to associate the Egress part of the A2B connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1024  

cirEmAtmPvcVccCnfrmTypeB2A 3.1.1751.2.18.6.6.1.23
The following is the description of this field This will be used in conjunction with the service type field to get the correct traffic behaviour. In the conformances the the 0 or 0plus1 refers to the clp bit in the cells. If 0plus1 is the bucket reference then the clp bit is ignored. If 0 is specified for the bucket then check only clp=0 cells. 1: Best Effort will try to send all cellsin a best effort way. This will follow the Aqueman Algorithm 2: one-bucket-notag-0plus1 will use 1 bucket i.e is the PCR(0+1) bucket and drop all cells in excess. 3: two-bucket-notag-0plus1-0plus1 uses 2 buckets. The 2 buckets are pcr(0+1) and scr(0+1). All cells conforming to both buckets will be passed through. The rest will be dropped. 4: two-bucket-notag-0plus1-0 uses 2 buckets. The 2 buckets are pcr(0+1) and scr(0) or pcr(0). Cells which conform to both buckets are passed through. The rest are dropped. 5: two-bucket-tag-0plus1-0 uses 2 buckets. The 2 buckets are pcr(0+1) and scr(0) or pcr(0). Cells which do not conform to the first bucket are dropped. Cells which do not conform to the 2nd bucket are tagged. 6: best-effort-tag. Tag all cells and then do a best effort.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER best-effort(1), one-bucket-notag-0plus1(2), two-bucket-notag-0plus1-0plus1(3), two-bucket-notag-0plus1-0(4), two-bucket-tag-0plus1-0(5), best-effort-tag(6)  

cirEmAtmPvcVccVUNIB 3.1.1751.2.18.6.6.1.24
VUNI to associate the Egress part of the A2B connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

cirEmAtmPvcVccAal2Cid 3.1.1751.2.18.6.6.1.25
Aal2 Cid Used to pack ce chan in an Atm Trunk. This value will be unique per Atm Trunk. This field will be applicable when Aal type is chosen to be Standard Aal2.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

cirEmAtmPvcVccOAMConnEndPtStatus 3.1.1751.2.18.6.6.1.26
Connection endpoint status. Valid only at connection endpoint.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ete-active(1), ete-ais-state(2), ete-rdi-state(3), ete-ais-rdi-state(4)  

cirEmAtmPvcVccOAMConnSegEndPtStatus 3.1.1751.2.18.6.6.1.27
Segment endpoint status. Valid only at segment/connection endpoints.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER seg-active(1), seg-ais-state(2), seg-rdi-state(3), seg-ais-rdi-state(4)  

cirEmAtmPvcVccConnFailureCauseA 3.1.1751.2.18.6.6.1.28
connestion status reason code
Status: current Access: read-only
OBJECT-TYPE    
  ConnFailureCause  

cirEmAtmPvcVccConnFailureCauseB 3.1.1751.2.18.6.6.1.29
connection status reason code
Status: current Access: read-only
OBJECT-TYPE    
  AtmConnFailureCause  

cirEmAtmPvcVccDigitCollectTypeA2B 3.1.1751.2.18.6.6.1.30
Identify the digital tone setting. dtmf -- dual tone multifrequency dialed digits, mf -- multifrequency dialed digits, mf-r2-frwd -- R2 multifrequency forward dialed digits. mf-r2-bkwd-- R2 multifrequency backward dialed digits
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), dtmf(2), mf(3), mf-r2-frwd(4), mf-r2-bkwd(5)  

cirEmAtmPvcVccDigitCollectTypeB2A 3.1.1751.2.18.6.6.1.31
Identify the digital tone setting. dtmf -- dual tone multifrequency dialed digits, mf -- multifrequency dialed digits, mf-r2-frwd -- R2 multifrequency forward dialed digits. mf-r2-bkwd-- R2 multifrequency backward dialed digits
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), dtmf(2), mf(3), mf-r2-frwd(4), mf-r2-bkwd(5)  

cirEmAtmPvcVccEncodingStdA2B 3.1.1751.2.18.6.6.1.32
These are profiles defined according to standards User-Profile - No restrictions or checks, user freedom to choose any combination of Params. Atm Forum - These are profies defined by AF in document AF-VMOA-0145.000. In these cases the Identifiers are used and not the table numbers. Itu-t - These profiles are used from the I-366-2.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER user(1), atmForum(2), itu-t(3)  

cirEmAtmPvcVccEncodingStdB2A 3.1.1751.2.18.6.6.1.33
These are profiles defined according to standards User-Profile - No restrictions or checks, user freedom to choose any combination of Params. Atm Forum - These are profies defined by AF in document AF-VMOA-0145.000. In these cases the Identifiers are used and not the table numbers. Itu-t - These profiles are used from the I-366-2.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER user(1), atmForum(2), itu-t(3)  

cirEmAtmPvcVccEncodingProfileIdA2B 3.1.1751.2.18.6.6.1.34
These are profiles defined according to standards User-Profile - No restrictions or checks, user freedom to choose any combination of Params. Atm Forum - These are profies defined by AF in document AF-VMOA-0145.000. In these cases the Identifiers are used and not the table numbers. Itu-t - These profiles are used from the I-366-2.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..256  

cirEmAtmPvcVccEncodingProfileIdB2A 3.1.1751.2.18.6.6.1.35
These are profiles defined according to standards User-Profile - No restrictions or checks, user freedom to choose any combination of Params. Atm Forum - These are profies defined by AF in document AF-VMOA-0145.000. In these cases the Identifiers are used and not the table numbers. Itu-t - These profiles are used from the I-366-2.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..256  

frAtmPvcVccTable 3.1.1751.2.18.6.7
Table of frame relay to ATM IWF connections
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FrAtmPvcVccEntry

frAtmPvcVccEntry 3.1.1751.2.18.6.7.1
Row definition of frame relay to ATM IWF connections
Status: current Access: not-accessible
OBJECT-TYPE    
  FrAtmPvcVccEntry  

frAtmPvcVccIfA 3.1.1751.2.18.6.7.1.1
Interface index for side A, the frame relay side, of a frame relay-atm PVC VCC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

frAtmPvcVccDlciA 3.1.1751.2.18.6.7.1.2
DLCI value for side A, the frame relay side, of a frame relay-atm PVC VCC connection. Valid range is a number between 0 and 1023.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

frAtmPvcVccIfB 3.1.1751.2.18.6.7.1.3
Interface index for side B, the atm side, of a frame relay-atm PVC VCC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

frAtmPvcVccVpiB 3.1.1751.2.18.6.7.1.4
VPI value for side B, the atm side, of a frame relay-atm PVC VCC connection. Valid range is a number between 0 and 4095.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..4095  

frAtmPvcVccVciB 3.1.1751.2.18.6.7.1.5
VCI value for side B, the atm side, of a frame relay-atm PVC VCC connection. Valid range is a number between 0 and 65535.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..65535  

frAtmPvcVccMaxFrameSizeIn 3.1.1751.2.18.6.7.1.6
The value of this object is the size in octets of the largest frame relay information field for this PVC in the ingress direction (out of the frame relay UNI).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

frAtmPvcVccBcIn 3.1.1751.2.18.6.7.1.7
The value of this object is equal to the committed burst size (Bc) parameter (measured in bits) for this PVC in the ingress direction (into the frame relay UNI).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

frAtmPvcVccBeIn 3.1.1751.2.18.6.7.1.8
The value of this object is equal to the excess burst size (Be) parameter (measured in bits) for this PVC in the ingress direction (into the frame relay UNI).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

frAtmPvcVccCirIn 3.1.1751.2.18.6.7.1.9
The value of this object is equal to the committed information rate (CIR) parameter (measured in bits per second) for this PVC in the ingress direction (into the frame relay UNI).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

frAtmPvcVccMaxFrameSizeOut 3.1.1751.2.18.6.7.1.10
The value of this object is the size in octets of the largest frame relay information field for this PVC in the egress direction (out of the frame relay UNI).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

frAtmPvcVccBcOut 3.1.1751.2.18.6.7.1.11
The value of this object is equal to the committed burst size (Bc) parameter (measured in bits) for this PVC in the egress direction (into the frame relay UNI).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

frAtmPvcVccBeOut 3.1.1751.2.18.6.7.1.12
The value of this object is equal to the excess burst size (Be) parameter (measured in bits) for this PVC in the egress direction (into the frame relay UNI)
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

frAtmPvcVccCirOut 3.1.1751.2.18.6.7.1.13
The value of this object is equal to the committed information rate (CIR) parameter (measured in bits per second) for this PVC in the egress direction (into the frame relay UNI).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

frAtmPvcVccServiceType 3.1.1751.2.18.6.7.1.14
service type, Frame relay traffic is carried by VBR type of service only.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ubr(1), vbr-nrt2(2), vbr-nrt1(3), vbr-rt2(4), vbr-rt1(5), vbr-express(6), gfr2(7)  

frAtmPvcVccFlow 3.1.1751.2.18.6.7.1.15
Flow Type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER duplex(1), simplexA2B(2), simplexB2A(3)  

frAtmPvcVccRowStatus 3.1.1751.2.18.6.7.1.16
row status
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

frAtmPvcVccTimeLenIn 3.1.1751.2.18.6.7.1.17
The time interval over which CIR and the burst sizes (Bc and Be) are measured in the A2B direction. The unit is milliseconds.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 64..4000  

frAtmPvcVccInterWorkingFuncIn 3.1.1751.2.18.6.7.1.18
InterWorking function.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER frf8-Transl(1), frf8-Pass(2), frf5(3)  

frAtmPvcVccTimeLenOut 3.1.1751.2.18.6.7.1.19
The time interval over which CIR and the burst sizes (Bc and Be) are measured in the A2B direction. The unit is milliseconds.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 64..4000  

frAtmPvcVccInterWorkingFuncOut 3.1.1751.2.18.6.7.1.20
InterWorking function.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER frf8-Transl(1), frf8-Pass(2), frf5(3)  

frAtmPvcVccPeakCellRateA2B 3.1.1751.2.18.6.7.1.21
Peak cell rate - side A, in cells per second, this will reflect the frame relay parameters in atm terms.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmPvcVccSusCellRateA2B 3.1.1751.2.18.6.7.1.22
Sustained cell rate - side A, in cells per second, this will reflect the frame relay parameters in atm terms.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmPvcVccMaxBurstSizeA2B 3.1.1751.2.18.6.7.1.23
Maximum burst size - side A, in cells, this will reflect the frame relay parameters in atm terms.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmPvcVccPeakCellRateB2A 3.1.1751.2.18.6.7.1.24
Peak cell rate - side B, in cells per second, this will reflect the frame relay parameters in atm terms.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmPvcVccSusCellRateB2A 3.1.1751.2.18.6.7.1.25
Sustained cell rate - side B, in cells per second, this will reflect the frame relay parameters in atm terms.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmPvcVccMaxBurstSizeB2A 3.1.1751.2.18.6.7.1.26
Maximum burst size - side B, in cells, this will reflect the frame relay parameters in atm terms.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmPvcVccConnectionStatus 3.1.1751.2.18.6.7.1.27
Indicates the current connections status. Active: All interfaces through which the connection is going are in service. Inactive: One of the end interfaces of the connection is not in service. The rest of the states apply to connections going through resource interfaces like DSP2 and FEC. These interfaces are dynamically allocated. InactiveA2B-B2A: Both the A2B and B2A resource interfaces are not in service. InactiveA2B: The A2B resource interface is not in service. InactiveB2A: The B2A resource interface is not in service. If an end interface and the resource interfaces are out of service, the status will be inactive because the end interfaces take priority.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER active(1), inactive(2), inactiveA2B-B2A(3), inactiveA2B(4), inactiveB2A(5)  

frAtmPvcVccDualHomed 3.1.1751.2.18.6.7.1.28
Does this PVC need a backup Dual homing PVC.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

frAtmPvcVccOamStatus 3.1.1751.2.18.6.7.1.29
Indicates the OAM monitoring status of side A. The 2 possible states are: Unsupp: No monitoring enabled. End-Pt: A side is only an end point, therefore it will respond to AIS/RDI.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unsupp(1), end-Pt(2), end-Seg-Pt(3)  

frAtmPvcVccViB 3.1.1751.2.18.6.7.1.30
VI to associate the Egress part of the A2B connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1024  

frAtmPvcVccCnfrmTypeB2A 3.1.1751.2.18.6.7.1.31
The following is the description of this field This will be used in conjunction with the service type field to get the correct traffic behaviour. In the conformances the the 0 or 0plus1 refers to the clp bit in the cells. If 0plus1 is the bucket reference then the clp bit is ignored. If 0 is specified for the bucket then check only clp=0 cells. 1: Best Effort will try to send all cellsin a best effort way. This will follow the Aqueman Algorithm 2: one-bucket-notag-0plus1 will use 1 bucket i.e is the PCR(0+1) bucket and drop all cells in excess. 3: two-bucket-notag-0plus1-0plus1 uses 2 buckets. The 2 buckets are pcr(0+1) and scr(0+1). All cells conforming to both buckets will be passed through. The rest will be dropped. 4: two-bucket-notag-0plus1-0 uses 2 buckets. The 2 buckets are pcr(0+1) and scr(0) or pcr(0). Cells which conform to both buckets are passed through. The rest are dropped. 5: two-bucket-tag-0plus1-0 uses 2 buckets. The 2 buckets are pcr(0+1) and scr(0) or pcr(0). Cells which do not conform to the first bucket are dropped. Cells which do not conform to the 2nd bucket are tagged. 6: best-effort-tag. Tag all cells and then do a best effort.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER best-effort(1), one-bucket-notag-0plus1(2), two-bucket-notag-0plus1-0plus1(3), two-bucket-notag-0plus1-0(4), two-bucket-tag-0plus1-0(5), best-effort-tag(6)  

frAtmPvcVccVUNIB 3.1.1751.2.18.6.7.1.32
VUNI to associate the Egress part of the A2B connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

frAtmPvcVccOAMConnEndPtStatus 3.1.1751.2.18.6.7.1.33
Connection endpoint status. Valid only at connection endpoint.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ete-active(1), ete-ais-state(2), ete-rdi-state(3), ete-ais-rdi-state(4)  

frAtmPvcVccOAMSegEndPtStatus 3.1.1751.2.18.6.7.1.34
Segment endpoint status. Valid only at segment/connection endpoint.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER seg-active(1), seg-ais-state(2), seg-rdi-state(3), seg-ais-rdi-state(4)  

frAtmPvcVccMfsB2A 3.1.1751.2.18.6.7.1.35
Maximum Frame Size for GFR traffic
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

frAtmPvcVccConnFailureCauseA 3.1.1751.2.18.6.7.1.36
connestion status reason code
Status: current Access: read-only
OBJECT-TYPE    
  FrConnFailureCause  

frAtmPvcVccConnFailureCauseB 3.1.1751.2.18.6.7.1.37
connection status reason code
Status: current Access: read-only
OBJECT-TYPE    
  AtmConnFailureCause  

frAtmPvcVccTrafficShapingA2B 3.1.1751.2.18.6.7.1.38
Traffic Shaping Support in the A2B direction.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

frFrPvcTable 3.1.1751.2.18.6.8
Table of frame relay to frame relay connections
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FrFrPvcEntry

frFrPvcEntry 3.1.1751.2.18.6.8.1
Row definition of frame relay to frame relay PVC connections
Status: current Access: not-accessible
OBJECT-TYPE    
  FrFrPvcEntry  

frFrPvcIfA 3.1.1751.2.18.6.8.1.1
Interface index for side A of a frame relay-frame relay PVC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

frFrPvcDlciA 3.1.1751.2.18.6.8.1.2
DLCI value for side A of a frame relay-frame relay PVC connection. Valid range is a number between 0 and 1023.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

frFrPvcIfB 3.1.1751.2.18.6.8.1.3
Interface index for side B of a frame relay-frame relay PVC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

frFrPvcDlciB 3.1.1751.2.18.6.8.1.4
DLCI value for side B of a frame relay-frame relay PVC connection. Valid range is a number between 0 and 1023.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

frFrPvcMaxFrameSizeA2B 3.1.1751.2.18.6.8.1.5
The value of this object is the size in octets of the largest frame relay information field for this PVC in the A to B direction.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

frFrPvcBcA2B 3.1.1751.2.18.6.8.1.6
The value of this object is equal to the committed burst size (Bc) parameter (measured in bits) for this PVC in the A to B direction.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

frFrPvcBeA2B 3.1.1751.2.18.6.8.1.7
The value of this object is equal to the excess burst size (Be) parameter (measured in bits) for this PVC in the A to B direction.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

frFrPvcCirA2B 3.1.1751.2.18.6.8.1.8
The value of this object is equal to the committed information rate (CIR) parameter (measured in bits per second) for this PVC in the A to B direction.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

frFrPvcMaxFrameSizeB2A 3.1.1751.2.18.6.8.1.9
The value of this object is the size in octets of the largest frame relay information field for this PVC in the B to A direction.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

frFrPvcBcB2A 3.1.1751.2.18.6.8.1.10
The value of this object is equal to the committed burst size (Bc) parameter (measured in bits) for this PVC in the B to A direction.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

frFrPvcBeB2A 3.1.1751.2.18.6.8.1.11
The value of this object is equal to the excess burst size (Be) parameter (measured in bits) for this PVC in the B to A direction.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

frFrPvcCirB2A 3.1.1751.2.18.6.8.1.12
The value of this object is equal to the committed information rate (CIR) parameter (measured in bits per second) for this PVC in the B to A direction.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

frFrPvcServiceType 3.1.1751.2.18.6.8.1.13
service type, Frame relay traffic is carried by VBR type of service only.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ubr(1), vbr-nrt2(2), vbr-nrt1(3), vbr-rt2(4), vbr-rt1(5), vbr-express(6)  

frFrPvcFlow 3.1.1751.2.18.6.8.1.14
Flow Type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER duplex(1), simplexA2B(2)  

frFrPvcRowStatus 3.1.1751.2.18.6.8.1.15
row status
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

frFrPvcTimeLenA2B 3.1.1751.2.18.6.8.1.16
The time interval over which CIR and the burst sizes (Bc and Be) are measured in the A2B direction. The unit is milliseconds.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 64..4000  

frFrPvcInterWorkingFuncA2B 3.1.1751.2.18.6.8.1.17
InterWorking function.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER frf8-Transl(1), frf8-Pass(2), frf5(3)  

frFrPvcTimeLenB2A 3.1.1751.2.18.6.8.1.18
The time interval over which CIR and the burst sizes (Bc and Be) are measured in the A2B direction. The unit is milliseconds.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 64..4000  

frFrPvcInterWorkingFuncB2A 3.1.1751.2.18.6.8.1.19
InterWorking function.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER frf8-Transl(1), frf8-Pass(2), frf5(3)  

frFrPvcPeakCellRateA2B 3.1.1751.2.18.6.8.1.20
Peak cell rate - side A, in cells per second, this will reflect the frame relay parameters in atm terms.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frFrPvcSusCellRateA2B 3.1.1751.2.18.6.8.1.21
Sustained cell rate - side A, in cells per second, this will reflect the frame relay parameters in atm terms.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frFrPvcMaxBurstSizeA2B 3.1.1751.2.18.6.8.1.22
Maximum burst size - side A, in cells, this will reflect the frame relay parameters in atm terms.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frFrPvcPeakCellRateB2A 3.1.1751.2.18.6.8.1.23
Peak cell rate - side B, in cells per second, this will reflect the frame relay parameters in atm terms.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frFrPvcSusCellRateB2A 3.1.1751.2.18.6.8.1.24
Sustained cell rate - side B, in cells per second, this will reflect the frame relay parameters in atm terms.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frFrPvcMaxBurstSizeB2A 3.1.1751.2.18.6.8.1.25
Maximum burst size - side B, in cells, this will reflect the frame relay parameters in atm terms.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frFrPvcConnectionStatus 3.1.1751.2.18.6.8.1.26
Indicates the current connections status. Active: All interfaces through which the connection is going are in service. Inactive: One of the end interfaces of the connection is not in service. The rest of the states apply to connections going through resource interfaces like DSP2 and FEC. These interfaces are dynamically allocated. InactiveA2B-B2A: Both the A2B and B2A resource interfaces are not in service. InactiveA2B: The A2B resource interface is not in service. InactiveB2A: The B2A resource interface is not in service. If an end interface and the resource interfaces are out of service, the status will be inactive because the end interfaces take priority.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER active(1), inactive(2), inactiveA2B-B2A(3), inactiveA2B(4), inactiveB2A(5)  

frFrPvcConnFailureCauseA 3.1.1751.2.18.6.8.1.27
connestion status reason code
Status: current Access: read-only
OBJECT-TYPE    
  FrConnFailureCause  

frFrPvcConnFailureCauseB 3.1.1751.2.18.6.8.1.28
connection status reason code
Status: current Access: read-only
OBJECT-TYPE    
  FrConnFailureCause  

vbrAtmPvcVccTable 3.1.1751.2.18.6.9
Table of terminal emulation to ATM network IWF connections
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VbrAtmPvcVccEntry

vbrAtmPvcVccEntry 3.1.1751.2.18.6.9.1
Row definition of terminal emulation to ATM network IWF connections
Status: current Access: not-accessible
OBJECT-TYPE    
  VbrAtmPvcVccEntry  

vbrAtmPvcVccIfA 3.1.1751.2.18.6.9.1.1
Interface index for side A, the variable bit rate side, of a variable bit rate-atm PVC VCC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

vbrAtmPvcVccIfB 3.1.1751.2.18.6.9.1.2
Interface index for side B, the atm side, of a variable bit rate-atm PVC VCC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

vbrAtmPvcVccVpiB 3.1.1751.2.18.6.9.1.3
VPI value for side B, the atm side, of a variable bit rate-atm PVC VCC connection. Valid range is a number between 0 and 4095.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..4095  

vbrAtmPvcVccVciB 3.1.1751.2.18.6.9.1.4
VCI value for side B, the atm side, of a variable bit rate-atm PVC VCC connection. Valid range is a number between 0 and 65535.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..65535  

vbrAtmPvcVccServiceType 3.1.1751.2.18.6.9.1.5
service type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ubr(1), vbr-nrt2(2), vbr-nrt1(3), vbr-rt2(4), vbr-rt1(5), vbr-express(6), gfr2(7)  

vbrAtmPvcVccPeakCellRateA2B 3.1.1751.2.18.6.9.1.6
peak cell rate - side A, in cell per second
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

vbrAtmPvcVccSusCellRateA2B 3.1.1751.2.18.6.9.1.7
sustained rate - side A, in cell per second
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

vbrAtmPvcVccMaxBurstSizeA2B 3.1.1751.2.18.6.9.1.8
maximum burst size - side A, in cells
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

vbrAtmPvcVccPeakCellRateB2A 3.1.1751.2.18.6.9.1.9
peak rate - side B, in cell per second.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

vbrAtmPvcVccSusCellRateB2A 3.1.1751.2.18.6.9.1.10
sustained rate - side B, in cell per second.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

vbrAtmPvcVccMaxBurstSizeB2A 3.1.1751.2.18.6.9.1.11
maximum burst size - side B, in cells.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

vbrAtmPvcVccFlow 3.1.1751.2.18.6.9.1.12
Flow type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER duplex(1), simplexA2B(2), simplexB2A(3)  

vbrAtmPvcVccRowStatus 3.1.1751.2.18.6.9.1.13
row status
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

vbrAtmPvcVccConnectionStatus 3.1.1751.2.18.6.9.1.14
Indicates the current connections status. Active: All interfaces through which the connection is going are in service. Inactive: One of the end interfaces of the connection is not in service. The rest of the states apply to connections going through resource interfaces like DSP2 and FEC. These interfaces are dynamically allocated. InactiveA2B-B2A: Both the A2B and B2A resource interfaces are not in service. InactiveA2B: The A2B resource interface is not in service. InactiveB2A: The B2A resource interface is not in service. If an end interface and the resource interfaces are out of service, the status will be inactive because the end interfaces take priority.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER active(1), inactive(2), inactiveA2B-B2A(3), inactiveA2B(4), inactiveB2A(5)  

vbrAtmPvcVccDualHomed 3.1.1751.2.18.6.9.1.15
Does this PVC need a backup Dual homing PVC.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

vbrAtmPvcVccOamStatus 3.1.1751.2.18.6.9.1.16
Indicates the OAM monitoring status of side A. The 2 possible states are: Unsupp: No monitoring enabled. End-Pt: A side is only an end point, therefore it will respond to AIS/RDI. End-Seg-Pt: Connection endPoint that is also a segment endPoint.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unsupp(1), end-Pt(2), end-Seg-Pt(3)  

vbrAtmPvcVccViB 3.1.1751.2.18.6.9.1.17
VI to associate the Egress part of the A2B connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1024  

vbrAtmPvcVccCnfrmTypeB2A 3.1.1751.2.18.6.9.1.18
The following is the description of this field This will be used in conjunction with the service type field to get the correct traffic behaviour. In the conformances the the 0 or 0plus1 refers to the clp bit in the cells. If 0plus1 is the bucket reference then the clp bit is ignored. If 0 is specified for the bucket then check only clp=0 cells. 1: Best Effort will try to send all cellsin a best effort way. This will follow the Aqueman Algorithm 2: one-bucket-notag-0plus1 will use 1 bucket i.e is the PCR(0+1) bucket and drop all cells in excess. 3: two-bucket-notag-0plus1-0plus1 uses 2 buckets. The 2 buckets are pcr(0+1) and scr(0+1). All cells conforming to both buckets will be passed through. The rest will be dropped. 4: two-bucket-notag-0plus1-0 uses 2 buckets. The 2 buckets are pcr(0+1) and scr(0) or pcr(0). Cells which conform to both buckets are passed through. The rest are dropped. 5: two-bucket-tag-0plus1-0 uses 2 buckets. The 2 buckets are pcr(0+1) and scr(0) or pcr(0). Cells which do not conform to the first bucket are dropped. Cells which do not conform to the 2nd bucket are tagged. 6: best-effort-tag. Tag all cells and then do a best effort.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER best-effort(1), one-bucket-notag-0plus1(2), two-bucket-notag-0plus1-0plus1(3), two-bucket-notag-0plus1-0(4), two-bucket-tag-0plus1-0(5), best-effort-tag(6)  

vbrAtmPvcVccVUNIB 3.1.1751.2.18.6.9.1.19
VUNI to associate the Egress part of the A2B connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

vbrAtmPvcVccOAMConnEndPtStatus 3.1.1751.2.18.6.9.1.20
Connection endpoint status. Valid only at connection endpoint.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ete-active(1), ete-ais-state(2), ete-rdi-state(3), ete-ais-rdi-state(4)  

vbrAtmPvcVccOAMSegEndPtStatus 3.1.1751.2.18.6.9.1.21
Segment endpoint status. Valid only at segment/connection endpoint.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER seg-active(1), seg-ais-state(2), seg-rdi-state(3), seg-ais-rdi-state(4)  

vbrAtmPvcVccMfsB2A 3.1.1751.2.18.6.9.1.22
Maximum Frame Size for GFR traffic
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

vbrAtmPvcVccConnFailureCauseA 3.1.1751.2.18.6.9.1.23
connestion status reason code
Status: current Access: read-only
OBJECT-TYPE    
  ConnFailureCause  

vbrAtmPvcVccConnFailureCauseB 3.1.1751.2.18.6.9.1.24
connection status reason code
Status: current Access: read-only
OBJECT-TYPE    
  AtmConnFailureCause  

vbrAtmPvcVccSarTypeB 3.1.1751.2.18.6.9.1.25
This field will be used to connect hdlc to atm directly when sar type is none or aal5 or go through dsp2 first when sar type is aal2Std.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), aal5(2), aal2Std(3)  

vbrAtmPvcVccAal2Cid 3.1.1751.2.18.6.9.1.26
Aal2 Cid Used to pack hdlc chan in an Atm Trunk. This value will be unique per Atm Trunk. This field will be applicable when Aal type is chosen to be Standard Aal2.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

vbrAtmPvcVccTrafficShapingA2B 3.1.1751.2.18.6.9.1.27
Traffic Shaping Support in the A2B direction.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

cirEmCirEmPvcTable 3.1.1751.2.18.6.10
Table of Circuit Emulation to Circuit Emulation
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CirEmCirEmPvcEntry

cirEmCirEmPvcEntry 3.1.1751.2.18.6.10.1
Row definition of circuit emulation to circuit emulation connections.
Status: current Access: not-accessible
OBJECT-TYPE    
  CirEmCirEmPvcEntry  

cirEmCirEmPvcIfA 3.1.1751.2.18.6.10.1.1
Interface index for side A of a circuit emulation-circuit emulation PVC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

cirEmCirEmPvcIfB 3.1.1751.2.18.6.10.1.2
Interface index for side B of a circuit emulation-circuit emulation PVC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

cirEmCirEmPvcEchoCancellationA2B 3.1.1751.2.18.6.10.1.5
Echo cancellation off/on
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), g165-nearEnd(2), g168(3)  

cirEmCirEmPvcFlow 3.1.1751.2.18.6.10.1.6
Flow Type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER duplex(1), simplexA2B(2)  

cirEmCirEmPvcRowStatus 3.1.1751.2.18.6.10.1.7
row status
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

cirEmCirEmPvcCodingTranslationA2B 3.1.1751.2.18.6.10.1.8
Coding rule translation type.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), muLaw2muLaw(2), aLaw2aLaw(3), muLaw2aLaw(4), aLaw2muLaw(5)  

cirEmCirEmPvcEchoCancellationB2A 3.1.1751.2.18.6.10.1.9
Echo cancellation off/on
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), g165-nearEnd(2), g168(3)  

cirEmCirEmPvcCodingTranslationB2A 3.1.1751.2.18.6.10.1.10
Coding rule translation type.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), muLaw2muLaw(2), aLaw2aLaw(3), muLaw2aLaw(4), aLaw2muLaw(5)  

cirEmCirEmPvcConnectionStatus 3.1.1751.2.18.6.10.1.11
Indicates the current connections status. Active: All interfaces through which the connection is going are in service. Inactive: One of the end interfaces of the connection is not in service. The rest of the states apply to connections going through resource interfaces like DSP2 and FEC. These interfaces are dynamically allocated. InactiveA2B-B2A: Both the A2B and B2A resource interfaces are not in service. InactiveA2B: The A2B resource interface is not in service. InactiveB2A: The B2A resource interface is not in service. If an end interface and the resource interfaces are out of service, the status will be inactive because the end interfaces take priority.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER active(1), inactive(2), inactiveA2B-B2A(3), inactiveA2B(4), inactiveB2A(5)  

cirEmCirEmPvcInterworking 3.1.1751.2.18.6.10.1.12
CE - CE interworking enable/disabled
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

cirEmCirEmPvcServiceType 3.1.1751.2.18.6.10.1.13
service type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER cbr-1(1), cbr-2(2), cbr-3(3), cbr-4(4)  

cirEmCirEmPvcConnFailureCauseA 3.1.1751.2.18.6.10.1.14
connestion status reason code
Status: current Access: read-only
OBJECT-TYPE    
  ConnFailureCause  

cirEmCirEmPvcConnFailureCauseB 3.1.1751.2.18.6.10.1.15
connection status reason code
Status: current Access: read-only
OBJECT-TYPE    
  ConnFailureCause  

vbrVbrPvcTable 3.1.1751.2.18.6.11
Table of terminal emulation to ATM network IWF connections
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VbrVbrPvcEntry

vbrVbrPvcEntry 3.1.1751.2.18.6.11.1
Row definition of terminal emulation to ATM network IWF connections
Status: current Access: not-accessible
OBJECT-TYPE    
  VbrVbrPvcEntry  

vbrVbrPvcIfA 3.1.1751.2.18.6.11.1.1
Interface index for side A of a variable bit rate-variable bit rate PVC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

vbrVbrPvcIfB 3.1.1751.2.18.6.11.1.2
Interface index for side B of a variable bit rate-variable bit rate PVC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

vbrVbrPvcPeakCellRateA2B 3.1.1751.2.18.6.11.1.3
peak cell rate - side A, in cell per second
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

vbrVbrPvcSusCellRateA2B 3.1.1751.2.18.6.11.1.4
sustained rate - side A, in cell per second
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

vbrVbrPvcMaxBurstSizeA2B 3.1.1751.2.18.6.11.1.5
maximum burst size - side A, in cells
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

vbrVbrPvcPeakCellRateB2A 3.1.1751.2.18.6.11.1.6
peak rate - side B, in cell per second.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

vbrVbrPvcSusCellRateB2A 3.1.1751.2.18.6.11.1.7
sustained rate - side B, in cell per second.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

vbrVbrPvcMaxBurstSizeB2A 3.1.1751.2.18.6.11.1.8
maximum burst size - side B, in cells.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

vbrVbrPvcFlow 3.1.1751.2.18.6.11.1.9
Flow Type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER duplex(1), simplexA2B(2)  

vbrVbrPvcRowStatus 3.1.1751.2.18.6.11.1.10
row status
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

vbrVbrPvcConnectionStatus 3.1.1751.2.18.6.11.1.11
Indicates the current connections status. Active: All interfaces through which the connection is going are in service. Inactive: One of the end interfaces of the connection is not in service. The rest of the states apply to connections going through resource interfaces like DSP2 and FEC. These interfaces are dynamically allocated. InactiveA2B-B2A: Both the A2B and B2A resource interfaces are not in service. InactiveA2B: The A2B resource interface is not in service. InactiveB2A: The B2A resource interface is not in service. If an end interface and the resource interfaces are out of service, the status will be inactive because the end interfaces take priority.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER active(1), inactive(2), inactiveA2B-B2A(3), inactiveA2B(4), inactiveB2A(5)  

vbrVbrPvcServiceType 3.1.1751.2.18.6.11.1.12
service type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ubr(1), vbr-nrt2(2), vbr-nrt1(3), vbr-rt2(4), vbr-rt1(5), vbr-express(6)  

vbrVbrPvcConnFailureCauseA 3.1.1751.2.18.6.11.1.13
connestion status reason code
Status: current Access: read-only
OBJECT-TYPE    
  ConnFailureCause  

vbrVbrPvcConnFailureCauseB 3.1.1751.2.18.6.11.1.14
connection status reason code
Status: current Access: read-only
OBJECT-TYPE    
  ConnFailureCause  

bridgeBridgePvcTable 3.1.1751.2.18.6.12
A table of bridge-bridge PVC connection
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    BridgeBridgePvcEntry

bridgeBridgePvcEntry 3.1.1751.2.18.6.12.1
Row definitions of bridge-bridge PVC connection attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  BridgeBridgePvcEntry  

bridgeBridgePvcIfA 3.1.1751.2.18.6.12.1.1
Interface index for side A of a bridge-bridge PVC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

bridgeBridgePvcIfB 3.1.1751.2.18.6.12.1.2
Interface index for side B of a bridge-bridge PVC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

bridgeBridgePvcRowStatus 3.1.1751.2.18.6.12.1.3
row status
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

bridgeBridgePvcConnectionStatus 3.1.1751.2.18.6.12.1.4
Indicates the current connections status. Active: All interfaces through which the connection is going are in service. Inactive: One of the end interfaces of the connection is not in service. The rest of the states apply to connections going through resource interfaces like DSP2 and FEC. These interfaces are dynamically allocated. InactiveA2B-B2A: Both the A2B and B2A resource interfaces are not in service. InactiveA2B: The A2B resource interface is not in service. InactiveB2A: The B2A resource interface is not in service. If an end interface and the resource interfaces are out of service, the status will be inactive because the end interfaces take priority.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER active(1), inactive(2), inactiveA2B-B2A(3), inactiveA2B(4), inactiveB2A(5)  

bridgeBridgePvcConnFailureCauseA 3.1.1751.2.18.6.12.1.5
connestion status reason code
Status: current Access: read-only
OBJECT-TYPE    
  ConnFailureCause  

bridgeBridgePvcConnFailureCauseB 3.1.1751.2.18.6.12.1.6
connection status reason code
Status: current Access: read-only
OBJECT-TYPE    
  ConnFailureCause  

bridgeAtmPvcVccTable 3.1.1751.2.18.6.13
Table of bridge Atm PVC VCC connection entries
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    BridgeAtmPvcVccEntry

bridgeAtmPvcVccEntry 3.1.1751.2.18.6.13.1
Row definition of bridge atm PVC VCC connection attribution.
Status: current Access: not-accessible
OBJECT-TYPE    
  BridgeAtmPvcVccEntry  

bridgeAtmPvcVccIfA 3.1.1751.2.18.6.13.1.1
Interface index for side A, the bridge side, of a bridge-atm PVC VCC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

bridgeAtmPvcVccIfB 3.1.1751.2.18.6.13.1.2
Interface index for side B, the atm side, of a bridge-atm PVC VCC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

bridgeAtmPvcVccVpiB 3.1.1751.2.18.6.13.1.3
VPI value for side B, the atm side, of a bridge-atm PVC VCC connection. Valid range is a number between 0 and 4095.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..4095  

bridgeAtmPvcVccVciB 3.1.1751.2.18.6.13.1.4
VCI value for side B, the atm side, of a bridge-atm PVC VCC connection. Valid range is a number between 0 and 65535.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..65535  

bridgeAtmPvcVccServiceType 3.1.1751.2.18.6.13.1.5
service type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ubr(1), vbr-nrt2(2), vbr-nrt1(3), vbr-rt2(4), vbr-rt1(5), vbr-express(6), gfr2(7)  

bridgeAtmPvcVccPeakCellRateB2A 3.1.1751.2.18.6.13.1.6
peak rate - side B, in cell per second.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

bridgeAtmPvcVccSusCellRateB2A 3.1.1751.2.18.6.13.1.7
sustained rate - side B, in cell per second.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

bridgeAtmPvcVccMaxBurstSizeB2A 3.1.1751.2.18.6.13.1.8
maximum burst size - side B, in cells.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

bridgeAtmPvcVccRowStatus 3.1.1751.2.18.6.13.1.9
row status
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

bridgeAtmPvcVccConnectionStatus 3.1.1751.2.18.6.13.1.10
Indicates the current connections status. Active: All interfaces through which the connection is going are in service. Inactive: One of the end interfaces of the connection is not in service. The rest of the states apply to connections going through resource interfaces like DSP2 and FEC. These interfaces are dynamically allocated. InactiveA2B-B2A: Both the A2B and B2A resource interfaces are not in service. InactiveA2B: The A2B resource interface is not in service. InactiveB2A: The B2A resource interface is not in service. If an end interface and the resource interfaces are out of service, the status will be inactive because the end interfaces take priority.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER active(1), inactive(2), inactiveA2B-B2A(3), inactiveA2B(4), inactiveB2A(5)  

bridgeAtmPvcVccDualHomed 3.1.1751.2.18.6.13.1.11
Does this PVC need a backup Dual homing PVC.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

bridgeAtmPvcVccViB 3.1.1751.2.18.6.13.1.12
VI to associate the Egress part of the A2B connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1024  

bridgeAtmPvcVccCnfrmTypeB2A 3.1.1751.2.18.6.13.1.14
The following is the description of this field This will be used in conjunction with the service type field to get the correct traffic behaviour. In the conformances the the 0 or 0plus1 refers to the clp bit in the cells. If 0plus1 is the bucket reference then the clp bit is ignored. If 0 is specified for the bucket then check only clp=0 cells. 1: Best Effort will try to send all cellsin a best effort way. This will follow the Aqueman Algorithm 2: one-bucket-notag-0plus1 will use 1 bucket i.e is the PCR(0+1) bucket and drop all cells in excess. 3: two-bucket-notag-0plus1-0plus1 uses 2 buckets. The 2 buckets are pcr(0+1) and scr(0+1). All cells conforming to both buckets will be passed through. The rest will be dropped. 4: two-bucket-notag-0plus1-0 uses 2 buckets. The 2 buckets are pcr(0+1) and scr(0) or pcr(0). Cells which conform to both buckets are passed through. The rest are dropped. 5: two-bucket-tag-0plus1-0 uses 2 buckets. The 2 buckets are pcr(0+1) and scr(0) or pcr(0). Cells which do not conform to the first bucket are dropped. Cells which do not conform to the 2nd bucket are tagged. 6: best-effort-tag. Tag all cells and then do a best effort.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER best-effort(1), one-bucket-notag-0plus1(2), two-bucket-notag-0plus1-0plus1(3), two-bucket-notag-0plus1-0(4), two-bucket-tag-0plus1-0(5), best-effort-tag(6)  

bridgeAtmPvcVccVUNIB 3.1.1751.2.18.6.13.1.15
VUNI to associate the Egress part of the A2B connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

bridgeAtmPvcVccMfsB2A 3.1.1751.2.18.6.13.1.16
Maximum Frame Size for GFR traffic
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

bridgeAtmPvcVccConnFailureCauseA 3.1.1751.2.18.6.13.1.17
connestion status reason code
Status: current Access: read-only
OBJECT-TYPE    
  ConnFailureCause  

bridgeAtmPvcVccConnFailureCauseB 3.1.1751.2.18.6.13.1.18
connection status reason code
Status: current Access: read-only
OBJECT-TYPE    
  AtmConnFailureCause  

bridgeAtmPvcVccOamStatus 3.1.1751.2.18.6.13.1.19
Indicates the OAM monitoring status of side A. The 3 possible states are: Unsupp: No monitoring enabled. End-Pt: A side is only an end point, therefore End-Seg-Pt: A side is both an end point and a segment point.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unsupp(1), end-Pt(2), end-Seg-Pt(3)  

bridgeAtmPvcVccTrafficShapingA2B 3.1.1751.2.18.6.13.1.20
Traffic Shaping Support in the A2B direction.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

cirEmAtmBkPvcVccTable 3.1.1751.2.18.6.14
This table is used to manage CES DHPVC backup pvc.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CirEmAtmBkPvcVccEntry

cirEmAtmBkPvcVccEntry 3.1.1751.2.18.6.14.1
An entry in the CES DHPVC table. There is one entry in the table corresponding to each active row in the cirEmAtmPvcVccTable for which the cirEmAtmPvcVccDualHomed object takes the value 'yes.'
Status: current Access: not-accessible
OBJECT-TYPE    
  CirEmAtmBkPvcVccEntry  

cirEmAtmBkPvcVccIfB 3.1.1751.2.18.6.14.1.1
Interface index for side B, the atm side, of a backup circuit emulation-atm DHPVC VCC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: read-write
OBJECT-TYPE    
  IntfIndex  

cirEmAtmBkPvcVccVpiB 3.1.1751.2.18.6.14.1.2
VPI value for side B, the atm side, of a backup circuit emulation-atm DHPVC VCC connection. Valid range is a number between 0 and 4095.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

cirEmAtmBkPvcVccVciB 3.1.1751.2.18.6.14.1.3
VCI value for side B, the atm side, of a backup circuit emulation-atm DHPVC VCC connection. Valid range is a number between 0 and 65535.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

cirEmAtmBkPvcVccActivePvc 3.1.1751.2.18.6.14.1.4
Current active PVC.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER primary(1), backup(2), none(3)  

cirEmAtmBkPvcVccAutoSwitch 3.1.1751.2.18.6.14.1.5
Auto switch back to primary link when primary link is recovered.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

cirEmAtmBkPvcVccRowStatus 3.1.1751.2.18.6.14.1.6
row status
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

cirEmAtmBkPvcVccViB 3.1.1751.2.18.6.14.1.7
VI to associate the Egress part of the A2B connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1024  

cirEmAtmBkPvcVccVUNIB 3.1.1751.2.18.6.14.1.8
VUNI to associate the Egress part of the A2B connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

cirEmAtmBkPvcVccConnFailureCauseB 3.1.1751.2.18.6.14.1.9
connection status reason code
Status: current Access: read-only
OBJECT-TYPE    
  AtmConnFailureCause  

vbrAtmBkPvcVccTable 3.1.1751.2.18.6.15
This table is used to manage terminal emulation DHPVC backup pvc.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VbrAtmBkPvcVccEntry

vbrAtmBkPvcVccEntry 3.1.1751.2.18.6.15.1
An entry in the terminal emulation DHPVC table. There is one entry in the table corresponding to each active row in the vbrAtmPvcVccTable for which the vbrAtmPvcVccDualHomed object takes the value 'yes'.
Status: current Access: not-accessible
OBJECT-TYPE    
  VbrAtmBkPvcVccEntry  

vbrAtmBkPvcVccIfB 3.1.1751.2.18.6.15.1.1
Interface index for side B, the atm side, of a backup terminal emulation-atm DHPVC VCC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: read-write
OBJECT-TYPE    
  IntfIndex  

vbrAtmBkPvcVccVpiB 3.1.1751.2.18.6.15.1.2
VPI value for side B, the atm side, of a backup terminal emulation-atm DHPVC VCC connection. Valid range is a number between 0 and 4095.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

vbrAtmBkPvcVccVciB 3.1.1751.2.18.6.15.1.3
VCI value for side B, the atm side, of a backup terminal emulation-atm DHPVC VCC connection. Valid range is a number between 0 and 65535.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

vbrAtmBkPvcVccActivePvc 3.1.1751.2.18.6.15.1.4
Current active PVC.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER primary(1), backup(2), none(3)  

vbrAtmBkPvcVccAutoSwitch 3.1.1751.2.18.6.15.1.5
Auto switch back to primary link when primary link is recovered.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

vbrAtmBkPvcVccRowStatus 3.1.1751.2.18.6.15.1.6
row status
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

vbrAtmBkPvcVccViB 3.1.1751.2.18.6.15.1.7
VI to associate the Egress part of the A2B connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1024  

vbrAtmBkPvcVccVUNIB 3.1.1751.2.18.6.15.1.8
VUNI to associate the Egress part of the A2B connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

vbrAtmBkPvcVccConnFailureCauseB 3.1.1751.2.18.6.15.1.9
connection status reason code
Status: current Access: read-only
OBJECT-TYPE    
  AtmConnFailureCause  

atmSpvcVccAddrTable 3.1.1751.2.18.6.16
Table of SPVC ATM network interface addresses.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmSpvcVccAddrEntry

atmSpvcVccAddrEntry 3.1.1751.2.18.6.16.1
Row definition of ATM SPVC address table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmSpvcVccAddrEntry  

atmSpvcVccIfA 3.1.1751.2.18.6.16.1.1
Interface index for side A of an ATM SPVC VCC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

atmSpvcVccAtmPortAddr 3.1.1751.2.18.6.16.1.2
Local ATM port NSAP address.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..20)  

atmSpvcVccAddrRowStatus 3.1.1751.2.18.6.16.1.3
This is used to configure a NSAP address on the local port. Only when the address is configured can SPVC connections be established.
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

atmSpvcVccTable 3.1.1751.2.18.6.17
Table of SPVC ATM virtual channel connections.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmSpvcVccEntry

atmSpvcVccEntry 3.1.1751.2.18.6.17.1
Row definition of ATM SPVC VCC connections.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmSpvcVccEntry  

atmSpvcVccVpiA 3.1.1751.2.18.6.17.1.1
VPI value for side A of an ATM SPVC VCC connection. Valid range is a number between 0 and 4095.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..4095  

atmSpvcVccVciA 3.1.1751.2.18.6.17.1.2
VCI value for side A of an ATM SPVC VCC connection. Valid range is a number between 0 and 65535.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..65535  

atmSpvcVccIfB 3.1.1751.2.18.6.17.1.3
Interface index for side B of an ATM SPVC VCC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: read-only
OBJECT-TYPE    
  IntfIndex  

atmSpvcVccVpiB 3.1.1751.2.18.6.17.1.4
VPI value for side B of an ATM SPVC VCC connection. Valid range is a number between 0 and 4095.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..4095  

atmSpvcVccVciB 3.1.1751.2.18.6.17.1.5
VCI value for side B of an ATM SPVC VCC connection. Valid range is a number between 0 and 65535.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

atmSpvcVccServiceTypeA2B 3.1.1751.2.18.6.17.1.6
Service type, ATM port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ubr(1), vbr-nrt2(2), vbr-nrt1(3), vbr-rt2(4), vbr-rt1(5), vbr-express(6), cbr4(7), cbr3(8), cbr2(9), cbr1(10)  

atmSpvcVccSarTypeA2B 3.1.1751.2.18.6.17.1.7
SAR type used in ATM adaption, ATM port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER aal5(1), aal3-4(2), aal2(3), aal1(4), null(5)  

atmSpvcVccPeakCellRateA2B 3.1.1751.2.18.6.17.1.8
Peak cell rate - side A, ATM port, in cells per second.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmSpvcVccSusCellRateA2B 3.1.1751.2.18.6.17.1.9
Sustained cell rate - side A, ATM port, in cells per second.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmSpvcVccMaxBurstSizeA2B 3.1.1751.2.18.6.17.1.10
Maximum burst size - side A, ATM port, in cells per second.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmSpvcVccFrwdErrCorrectionA2B 3.1.1751.2.18.6.17.1.11
Forward error correction scheme, ATM port side.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), eighthRate(2), quarterRate(3), halfRate(4), autoHiQ(5), auto(6), autoLoQ(7)  

atmSpvcVccServiceTypeB2A 3.1.1751.2.18.6.17.1.12
Service type, ATM trunk side.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ubr(1), vbr-nrt2(2), vbr-nrt1(3), vbr-rt2(4), vbr-rt1(5), vbr-express(6), cbr4(7), cbr3(8), cbr2(9), cbr1(10)  

atmSpvcVccSarTypeB2A 3.1.1751.2.18.6.17.1.13
SAR type used in ATM adaption, ATM trunk side.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER aal5(1), aal3-4(2), aal2(3), aal1(4), null(5)  

atmSpvcVccPeakCellRateB2A 3.1.1751.2.18.6.17.1.14
Peak cell rate - side B, ATM trunk, in cells per second.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmSpvcVccSusCellRateB2A 3.1.1751.2.18.6.17.1.15
Sustained cell rate - side B, ATM trunk, in cells per second.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmSpvcVccMaxBurstSizeB2A 3.1.1751.2.18.6.17.1.16
Maximum burst size - side A, ATM trunk, in cells per second.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmSpvcVccFrwdErrCorrectionB2A 3.1.1751.2.18.6.17.1.17
Forward error correction scheme, ATM trunk side.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), eighthRate(2), quarterRate(3), halfRate(4), autoHiQ(5), auto(6), autoLoQ(7)  

atmSpvcVccFlow 3.1.1751.2.18.6.17.1.18
Type of flow, pointToMultipointA2B is for future support.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER duplex(1), simplexA2B(2), pointToMultipointA2B(3), simplexB2A(4)  

atmSpvcVccType 3.1.1751.2.18.6.17.1.19
Type of connection.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER nonsecured(1), secured(2)  

atmSpvcVccConnType 3.1.1751.2.18.6.17.1.20
The type of connection: activeSvc - attempt calls, whenever not established. passiveSvc - accept calls.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER activeSvc(1), passiveSvc(2)  

atmSpvcVccLeafReference 3.1.1751.2.18.6.17.1.21
An arbitrary integer which serves to distinguish the mulitple leaves attached to a root of a point-to-multipoint SPVC. If point-to-point SPVC, the value should be 1.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

atmSpvcVccOperStatus 3.1.1751.2.18.6.17.1.22
The operation status of the connection: other - none of the types specified below. establishmentInProgress - connection is not operational, but call attempts are ongoing. connected - connection is currently operational. retriesExhausted - retry limit has been reached and call attempts have ceased. noAddressSupplied - no remote address has been configured, so no call attempts are initiated. lowerLayerDown - SPVC handler is not operational.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER other(1), establishmentInProgress(2), connected(3), retriesExhausted(4), noAddressSupplied(5), lowerLayerDown(6)  

atmSpvcVccRowStatus 3.1.1751.2.18.6.17.1.23
Used to create and delete a soft PVC. When this object is set to 'active', an attempt is made to set up the soft PVC. When this object has the value 'active' and is set to another value, any setup or connection in-progress is released.
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

atmSpvcVccViA 3.1.1751.2.18.6.17.1.24
VI to associate the Egress part of the B2A connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1024  

atmSpvcVccViB 3.1.1751.2.18.6.17.1.25
VI to associate the Egress part of the A2B connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1024  

atmSpvcVccTrafficShapingA2B 3.1.1751.2.18.6.17.1.26
Traffic Shaping Support in the A2B direction.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

atmSpvcVccTrafficShapingB2A 3.1.1751.2.18.6.17.1.27
Traffic Shaping Support in the B2A direction.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

atmSpvcVccActiveSvcTable 3.1.1751.2.18.6.18
The table used to manage active SVCs established across ATM networks between ATM entities.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmSpvcVccActiveSvcEntry

atmSpvcVccActiveSvcEntry 3.1.1751.2.18.6.18.1
An entry in the ATM active SVC table. There is one entry in the table corresponding to each active row in the atm SPVC VCC Table for which the atmSpvcVccConnType takes the value 'activeSvc'.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmSpvcVccActiveSvcEntry  

atmSpvcVccRemoteAtmPortAddr 3.1.1751.2.18.6.18.1.1
Remote ATM port NSAP address, not meaningful if passive type of connection.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..20)  

atmSpvcVccRemoteSelectType 3.1.1751.2.18.6.18.1.2
Indicates whether the remote VPI/VCI values are to be used at the destination. If 'any' is used, the destination switch will choose the VPI/VCI values. In such a case, once the SPVC is connected, the value of this object will change to 'required', such that the same VPI/VCI values will continue to be used even if the connection is torn down and re-established. If the value 'required' is specified, the values: atmSpvcVccRemoteVpi and atmSpvcVccRemoteVci, must be supplied and are used at the destination.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER required(1), any(2)  

atmSpvcVccRemoteVpi 3.1.1751.2.18.6.18.1.3
VPI value to be used at the destination of an ATM SPVC VCC connection. Valid range is a number between 0 and 4095. If atmSpvcVccRemoteSelectType is configured as 'any', then this value is not relevant.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

atmSpvcVccRemoteVci 3.1.1751.2.18.6.18.1.4
VCI value to be used at the destination of an ATM SPVC VCC connection. Valid range is a number between 0 and 65535. If atmSpvcVccRemoteSelectType is configured as 'any', then this value is not relevant.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

atmSpvcVccRetryInterval 3.1.1751.2.18.6.18.1.5
The time to wait before attempting to establish the SVC after a previous failed call attempt. A value of 0 indicates retry will be attempted immediately.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..3600  

atmSpvcVccRetryLimit 3.1.1751.2.18.6.18.1.6
A maximum limit on how many retries should be attempted. A value of 0 indicates no limit.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

atmSpvcVccRestart 3.1.1751.2.18.6.18.1.7
The active SVC is released, if necessary, and a new setup procedure is begun if 'restart', otherwise, noop.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER restart(1), noop(2)  

atmSpvcVccRetryFailure 3.1.1751.2.18.6.18.1.8
Indicates how many attempts to establish the connection have failed. It it reset whenever a connection is successfully established or the SVC is restarted.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSpvcVccReleaseCause 3.1.1751.2.18.6.18.1.9
CAUSE field value of the last RELEASE message received for this SVC.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..127  

atmSpvcVccReleaseDiag 3.1.1751.2.18.6.18.1.10
DIAGNOSTICS field value of the last RELEASE message received for this SVC.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..8)  

cirEmAtmSpvcVccTable 3.1.1751.2.18.6.19
Table of Circuit Emulation to ATM Soft PVCs.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CirEmAtmSpvcVccEntry

cirEmAtmSpvcVccEntry 3.1.1751.2.18.6.19.1
Row definition of circuit emulation to ATM SPVC connections.
Status: current Access: not-accessible
OBJECT-TYPE    
  CirEmAtmSpvcVccEntry  

cirEmAtmSpvcVccIfA 3.1.1751.2.18.6.19.1.1
Interface index for side A, the circuit emulation side, of a circuit emulation-atm SPVC VCC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

cirEmAtmSpvcVccIfB 3.1.1751.2.18.6.19.1.2
Interface index for side B, the atm side, of a circuit emulation-atm SPVC VCC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: read-only
OBJECT-TYPE    
  IntfIndex  

cirEmAtmSpvcVccVpiB 3.1.1751.2.18.6.19.1.3
VPI value for side B, the atm side, of a circuit emulation-atm SPVC VCC connection. Valid range is a number between 0 and 4095.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..4095  

cirEmAtmSpvcVccVciB 3.1.1751.2.18.6.19.1.4
VCI value for side B, the atm side, of a circuit emulation-atm SPVC VCC connection. Valid range is a number between 0 and 65535.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

cirEmAtmSpvcVccVoiceCompressionA2B 3.1.1751.2.18.6.19.1.5
Voice Compression Algorithm
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), g726-16k(2), g726-24k(3), g726-32k(4), g726-40k(5)  

cirEmAtmSpvcVccSilenceDetectionA2B 3.1.1751.2.18.6.19.1.6
silence detection off/on
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

cirEmAtmSpvcVccEchoCancellationA2B 3.1.1751.2.18.6.19.1.7
Echo Cancellation Algorithm
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), g165-nearEnd(2), g168(3)  

cirEmAtmSpvcVccCngToneDetectionA2B 3.1.1751.2.18.6.19.1.8
Calling Tone Detection Algorithm, one of the enum value, g726-32k(3) is obsoleted on 01Mar99 such that user would not be able to configure CE-ATM
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), bypass(2), g726-32k(3)  

cirEmAtmSpvcVccCodingTranslationA2B 3.1.1751.2.18.6.19.1.9
Coding rule translation type.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), muLaw2muLaw(2), aLaw2aLaw(3), muLaw2aLaw(4), aLaw2muLaw(5)  

cirEmAtmSpvcVccVoiceCompressionB2A 3.1.1751.2.18.6.19.1.10
Voice Compression Algorithm
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), g726-16k(2), g726-24k(3), g726-32k(4), g726-40k(5)  

cirEmAtmSpvcVccSilenceDetectionB2A 3.1.1751.2.18.6.19.1.11
silence detection off/on
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

cirEmAtmSpvcVccEchoCancellationB2A 3.1.1751.2.18.6.19.1.12
Echo Cancellation Algorithm
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), g165-nearEnd(2), g168(3)  

cirEmAtmSpvcVccCngToneDetectionB2A 3.1.1751.2.18.6.19.1.13
Calling Tone Detection Algorithm, one of the enum value, g726-32k(3) is obsoleted on 01Mar99 such that user would not be able to configure CE-ATM
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), bypass(2), g726-32k(3)  

cirEmAtmSpvcVccCodingTranslationB2A 3.1.1751.2.18.6.19.1.14
Coding rule translation type.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), muLaw2muLaw(2), aLaw2aLaw(3), muLaw2aLaw(4), aLaw2muLaw(5)  

cirEmAtmSpvcVccFlow 3.1.1751.2.18.6.19.1.15
Flow Type, pointToMultipointA2B and pointToMultipointB2A are for future support.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER duplex(1), simplexA2B(2), simplexB2A(3), pointToMultipointA2B(4), pointToMultipointB2A(5)  

cirEmAtmSpvcVccServiceType 3.1.1751.2.18.6.19.1.16
service type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER cbr-1(1), cbr-2(2), cbr-3(3), cbr-4(4)  

cirEmAtmSpvcVccConnType 3.1.1751.2.18.6.19.1.17
The type of connection: activeSvc - attempt calls, whenever not established; passiveSvc - accepts calls
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER activeSvc(1), passiveSvc(2)  

cirEmAtmSpvcVccCePortAddr 3.1.1751.2.18.6.19.1.18
local CES port nsap address
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..20)  

cirEmAtmSpvcVccOperStatus 3.1.1751.2.18.6.19.1.19
other - none of the types specified below; establishmentInProgress - connection is not operational, but call attempts are ongoing; connected - connection is currently operational; retriesExhausted - retry limit has been reached and call attempts have ceased; noAddressSupplied - no remote address has been configured, so no call attempts are initiated; lowerLayerDown - SPVC handler is not operational.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER other(1), establishmentInProgress(2), connected(3), retriesExhausted(4), noAddressSupplied(5), lowerLayerDown(6)  

cirEmAtmSpvcVccRowStatus 3.1.1751.2.18.6.19.1.20
Used to create and delete a soft PVCC. When this object is set to 'active' an attempt is made to set up the soft PVCC. When this object has the value 'active' and is set to another value, any set-up or connection in-progess is released.
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

cirEmAtmSpvcVccViB 3.1.1751.2.18.6.19.1.21
VI to associate the Egress part of the B2A connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1024  

cirEmAtmSpvcVccActiveSvcTable 3.1.1751.2.18.6.20
The table used to manage active SVCs established across ATM networks between CES entities.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CirEmAtmSpvcVccActiveSvcEntry

cirEmAtmSpvcVccActiveSvcEntry 3.1.1751.2.18.6.20.1
An entry in the CES active SVC table. There is one entry in the table corresponding to each active row in the cirEmAtmSpvcVccRowStatus for which the cirEmAtmSpvcVccConnType takes the value 'activeSvc'.
Status: current Access: not-accessible
OBJECT-TYPE    
  CirEmAtmSpvcVccActiveSvcEntry  

cirEmAtmSpvcVccRemoteCePortAddr 3.1.1751.2.18.6.20.1.1
The ATM address supporting the corresponding far end CES IWF process. If no address is supplied, no attempts to establish the active SVC are initiated.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..20)  

cirEmAtmSpvcVccRetryInterval 3.1.1751.2.18.6.20.1.2
The time to wait before attempting to establish the SVC after previous failed call attempt. 0 indicates retry will be attempted immediately.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..3600  

cirEmAtmSpvcVccRetryLimit 3.1.1751.2.18.6.20.1.3
A maximum limit on how many retries. 0 indicates no limit.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

cirEmAtmSpvcVccRestart 3.1.1751.2.18.6.20.1.4
restart, the active SVC is released if necessary and a new setup procedure is begun; or noop
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER restart(1), noop(2)  

cirEmAtmSpvcVccRetryFailure 3.1.1751.2.18.6.20.1.5
Indicates how many attempts to establish the connection have failed. It is reset whenever a connection is successfully established or the SVC is restarted.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmSpvcVccReleaseCause 3.1.1751.2.18.6.20.1.6
CAUSE field value of the last RELEASE message received for this SVC.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..127  

cirEmAtmSpvcVccReleaseDiag 3.1.1751.2.18.6.20.1.7
DIAGNOSTICS field value of the last RELEASE message received for this SVC.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..8)  

vbrAtmSpvcVccTable 3.1.1751.2.18.6.21
Table of SPVC atm virtual channel connections
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VbrAtmSpvcVccEntry

vbrAtmSpvcVccEntry 3.1.1751.2.18.6.21.1
Row definition of atm SPVC VCC connections
Status: current Access: not-accessible
OBJECT-TYPE    
  VbrAtmSpvcVccEntry  

vbrAtmSpvcVccIfA 3.1.1751.2.18.6.21.1.1
Interface index for side A, the variable bit rate side, of a variable bit rate-atm SPVC VCC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

vbrAtmSpvcVccIfB 3.1.1751.2.18.6.21.1.2
Interface index for side B, the atm side, of a variable bit rate-atm SPVC VCC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: read-only
OBJECT-TYPE    
  IntfIndex  

vbrAtmSpvcVccVpiB 3.1.1751.2.18.6.21.1.3
VPI value for side B, the atm side, of a variable bit rate-atm SPVC VCC connection. Valid range is a number between 0 and 4095.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..4095  

vbrAtmSpvcVccVciB 3.1.1751.2.18.6.21.1.4
VCI value for side B, the atm side, of a variable bit rate-atm SPVC VCC connection. Valid range is a number between 0 and 65535.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

vbrAtmSpvcVccServiceType 3.1.1751.2.18.6.21.1.5
service type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ubr(1), vbr-nrt1(2), vbr-nrt2(3), vbr-rt1(4), vbr-rt2(5), vbr-express(6)  

vbrAtmSpvcVccPeakCellRateA2B 3.1.1751.2.18.6.21.1.6
peak cell rate - side A, in cell per second
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcVccSusCellRateA2B 3.1.1751.2.18.6.21.1.7
sustained rate - side A, in cell per second
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcVccMaxBurstSizeA2B 3.1.1751.2.18.6.21.1.8
maximum burst size - side A, in cells
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcVccPeakCellRateB2A 3.1.1751.2.18.6.21.1.9
peak rate - side B, ATM trunk, in cell per second.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcVccSusCellRateB2A 3.1.1751.2.18.6.21.1.10
sustained rate - side B, ATM trunk, in cell per second.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcVccMaxBurstSizeB2A 3.1.1751.2.18.6.21.1.11
maximum burst size - side B, ATM trunk, in cells.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcVccFlow 3.1.1751.2.18.6.21.1.12
type of flow
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER duplex(1), simplexA2B(2), simplexB2A(3)  

vbrAtmSpvcVccConnType 3.1.1751.2.18.6.21.1.13
The type of connection: activeSvc - attempt calls, whenever not established; passiveSvc - accepts calls
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER activeSvc(1), passiveSvc(2)  

vbrAtmSpvcVccVbrPortAddr 3.1.1751.2.18.6.21.1.14
local Vbr port nsap address
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..20)  

vbrAtmSpvcVccOperStatus 3.1.1751.2.18.6.21.1.15
other - none of the types specified below; establishmentInProgress - connection is not operational, but call attempts are ongoing; connected - connection is currently operational; retriesExhausted - retry limit has been reached and call attempts have ceased; noAddressSupplied - no remote address has been configured, so no call attempts are initiated; lowerLayerDown - SPVC handler is not operational.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER other(1), establishmentInProgress(2), connected(3), retriesExhausted(4), noAddressSupplied(5), lowerLayerDown(6)  

vbrAtmSpvcVccRowStatus 3.1.1751.2.18.6.21.1.16
Used to create and delete a soft PVCC. When this object is set to 'active' an attempt is made to set up the soft PVCC. When this object has the value 'active' and is set to another value, any set-up or connection in-progess is released.
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

vbrAtmSpvcVccViB 3.1.1751.2.18.6.21.1.17
VI to associate the Egress part of the B2A connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1024  

vbrAtmSpvcVccTrafficShapingA2B 3.1.1751.2.18.6.21.1.18
Traffic Shaping Support in the A2B direction.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

vbrAtmSpvcVccActiveSvcTable 3.1.1751.2.18.6.22
The table used to manage active SVCs established across ATM networks between ATM entities.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VbrAtmSpvcVccActiveSvcEntry

vbrAtmSpvcVccActiveSvcEntry 3.1.1751.2.18.6.22.1
An entry in the Terminal Emulation ATM active SVC table. There is one entry in the table corresponding to each active row in the vbrAtmSpvcVccTable for which the vbrAtmSpvcVccConnType takes the value 'activeSvc'.
Status: current Access: not-accessible
OBJECT-TYPE    
  VbrAtmSpvcVccActiveSvcEntry  

vbrAtmSpvcVccRemoteVbrPortAddr 3.1.1751.2.18.6.22.1.1
remote VBR port nsap address implemening IWF, not meaningful if passive type of connection
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..20)  

vbrAtmSpvcVccRetryInterval 3.1.1751.2.18.6.22.1.2
the time to wait before attempting to establish the SVC after previous failed call attempt. 0 indicates retry will be attempted immediately.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..3600  

vbrAtmSpvcVccRetryLimit 3.1.1751.2.18.6.22.1.3
a maximum limit on how many retries. 0 indicates no limit.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

vbrAtmSpvcVccRestart 3.1.1751.2.18.6.22.1.4
restart, the active SVC is released if necessary and a new setup procedure is begun; or noop
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER restart(1), noop(2)  

vbrAtmSpvcVccRetryFailure 3.1.1751.2.18.6.22.1.5
indicates how many attempts to establish the connection have failed. It is reset whenever a connection is successfully established or the SVC is restarted.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcVccReleaseCause 3.1.1751.2.18.6.22.1.6
CAUSE field value of the last RELEASE message received for this SVC
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..127  

vbrAtmSpvcVccReleaseDiag 3.1.1751.2.18.6.22.1.7
DIAGNOSTICS field value of the last RELEASE message received for this SVC
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..8)  

atmSpvcVccRlsTable 3.1.1751.2.18.6.23
This table is an extension of atmSpvcVccTable and is used to release a ATM-ATM SPVC connection without deleting the configured data.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmSpvcVccRlsEntry

atmSpvcVccRlsEntry 3.1.1751.2.18.6.23.1
Row definition of CES SPVC release table. This entry is created whenever an entry is created in atmSpvcVccTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmSpvcVccRlsEntry  

atmSpvcVccRelease 3.1.1751.2.18.6.23.1.1
Release the connnection established on the endpoint and if the endpoint is Active, do not retry.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER release(1), noop(2)  

cirEmAtmSpvcVccRlsTable 3.1.1751.2.18.6.24
This table is an extension of cirEmAtmSpvcVccTable and is used to release a TE-ATM SPVC connection without deleting the configured data.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CirEmAtmSpvcVccRlsEntry

cirEmAtmSpvcVccRlsEntry 3.1.1751.2.18.6.24.1
Row definition of CES SPVC release table. This entry is created whenever an entry is created in cirEmAtmSpvcVccTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  CirEmAtmSpvcVccRlsEntry  

cirEmAtmSpvcVccRelease 3.1.1751.2.18.6.24.1.1
Release the connnection established on the endpoint and if the endpoint is Active, do not retry.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER release(1), noop(2)  

vbrAtmSpvcVccRlsTable 3.1.1751.2.18.6.25
This table is an extension of vbrAtmSpvcVccTable and is used to release a TE-ATM SPVC connection without deleting the configured data.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VbrAtmSpvcVccRlsEntry

vbrAtmSpvcVccRlsEntry 3.1.1751.2.18.6.25.1
Row definition of TE SPVC release table. This entry is created whenever an entry is created in vbrAtmSpvcVccTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  VbrAtmSpvcVccRlsEntry  

vbrAtmSpvcVccRelease 3.1.1751.2.18.6.25.1.1
Release the connnection established on the endpoint and if the endpoint is Active, do not retry.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER release(1), noop(2)  

frAtmBkPvcVccTable 3.1.1751.2.18.6.26
This table is used to manage frame relay DHPVC backup pvc.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FrAtmBkPvcVccEntry

frAtmBkPvcVccEntry 3.1.1751.2.18.6.26.1
An entry in the frame relay DHPVC table. There is one entry in the table corresponding to each active row in the frAtmPvcVccTable for which the frAtmPvcVccDualHomed object takes the value 'yes.'
Status: current Access: not-accessible
OBJECT-TYPE    
  FrAtmBkPvcVccEntry  

frAtmBkPvcVccIfB 3.1.1751.2.18.6.26.1.1
Interface index for side B, the atm side, of a backup frame relay-atm DHPVC VCC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: read-write
OBJECT-TYPE    
  IntfIndex  

frAtmBkPvcVccVpiB 3.1.1751.2.18.6.26.1.2
VPI value for side B, the atm side, of a backup frame relay-atm DHPVC VCC connection. Valid range is a number between 0 and 4095.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

frAtmBkPvcVccVciB 3.1.1751.2.18.6.26.1.3
VCI value for side B, the atm side, of a backup frame relay-atm DHPVC VCC connection. Valid range is a number between 0 and 65535.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

frAtmBkPvcVccActivePvc 3.1.1751.2.18.6.26.1.4
Current active PVC.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER primary(1), backup(2), none(3)  

frAtmBkPvcVccAutoSwitch 3.1.1751.2.18.6.26.1.5
Auto switch back to primary link when primary link is recovered.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

frAtmBkPvcVccRowStatus 3.1.1751.2.18.6.26.1.6
row status
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

frAtmBkPvcVccViB 3.1.1751.2.18.6.26.1.7
VI to associate the Egress part of the A2B connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1024  

frAtmBkPvcVccVUNIB 3.1.1751.2.18.6.26.1.8
VUNI to associate the Egress part of the A2B connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

frAtmBkPvcVccConnFailureCauseB 3.1.1751.2.18.6.26.1.9
connection status reason code
Status: current Access: read-only
OBJECT-TYPE    
  AtmConnFailureCause  

atmBkPvcVccTable 3.1.1751.2.18.6.27
This table is used to manage ATM to ATM DHPVC backup pvc.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmBkPvcVccEntry

atmBkPvcVccEntry 3.1.1751.2.18.6.27.1
An entry in the ATM to ATM DHPVC table. There is one entry in the table corresponding to each active row in the atmPvcVccTable for which the atmPvcVccDualHomed object takes the value 'yes'.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmBkPvcVccEntry  

atmBkPvcVccIfB 3.1.1751.2.18.6.27.1.1
Interface index for side B, the atm side, of a backup ATM-to-ATM DHPVC VCC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: read-write
OBJECT-TYPE    
  IntfIndex  

atmBkPvcVccVpiB 3.1.1751.2.18.6.27.1.2
VPI value for side B, the atm side, of a backup ATM-to-ATM DHPVC VCC connection. Valid range is a number between 0 and 4095.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

atmBkPvcVccVciB 3.1.1751.2.18.6.27.1.3
VCI value for side B, the atm side, of a backup ATM-to-ATM DHPVC VCC connection. Valid range is a number between 0 and 65535.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

atmBkPvcVccActivePvc 3.1.1751.2.18.6.27.1.4
Current active PVC.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER primary(1), backup(2), none(3)  

atmBkPvcVccAutoSwitch 3.1.1751.2.18.6.27.1.5
Auto switch back to primary link when primary link is recovered.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

atmBkPvcVccRowStatus 3.1.1751.2.18.6.27.1.6
row status
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

atmBkPvcVccViB 3.1.1751.2.18.6.27.1.7
VI to associate the Egress part of the A2B connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1024  

atmBkPvcVccVUNIB 3.1.1751.2.18.6.27.1.8
VUNI to associate the Egress part of the A2B connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

atmBkPvcVccConnFailureCauseB 3.1.1751.2.18.6.27.1.9
connection status reason code
Status: current Access: read-only
OBJECT-TYPE    
  AtmConnFailureCause  

atmBkPvcVpcTable 3.1.1751.2.18.6.28
This table is used to manage ATM to ATM DHPVC backup pvc.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmBkPvcVpcEntry

atmBkPvcVpcEntry 3.1.1751.2.18.6.28.1
An entry in the ATM to ATM DHPVC table. There is one entry in the table corresponding to each active row in the atmPvcVpcTable for which the atmPvcVpcDualHomed object takes the value 'yes'.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmBkPvcVpcEntry  

atmBkPvcVpcIfB 3.1.1751.2.18.6.28.1.1
Interface index for side B of an ATM-to-ATM PVC VPC backup DHPVC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: read-write
OBJECT-TYPE    
  IntfIndex  

atmBkPvcVpcVpiB 3.1.1751.2.18.6.28.1.2
VPI value for side B of an ATM-to-ATM PVC VPC backup DHPVC connection. Valid range is a number between 0 and 4095.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

atmBkPvcVpcActivePvc 3.1.1751.2.18.6.28.1.3
Current active PVC.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER primary(1), backup(2), none(3)  

atmBkPvcVpcAutoSwitch 3.1.1751.2.18.6.28.1.4
Auto switch back to primary link when primary link is recovered.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

atmBkPvcVpcRowStatus 3.1.1751.2.18.6.28.1.5
row status
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

atmBkPvcVpcViB 3.1.1751.2.18.6.28.1.6
VI to associate the Egress part of the A2B connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1024  

atmBkPvcVpcVUNIB 3.1.1751.2.18.6.28.1.7
VUNI to associate the Egress part of the A2B connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

atmBkPvcVpcConnFailureCauseB 3.1.1751.2.18.6.28.1.8
connection status reason code
Status: current Access: read-only
OBJECT-TYPE    
  AtmConnFailureCause  

bridgeAtmBkPvcVccTable 3.1.1751.2.18.6.29
This table is used to manage bridge to atm DHPVC backup pvc.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    BridgeAtmBkPvcVccEntry

bridgeAtmBkPvcVccEntry 3.1.1751.2.18.6.29.1
An entry in the bridge to atm DHPVC table. There is one entry in the table corresponding to each active row in the bridgeAtmPvcVccTable for which the bridgeAtmPvcVccDualHomed object takes the value 'yes'.
Status: current Access: not-accessible
OBJECT-TYPE    
  BridgeAtmBkPvcVccEntry  

bridgeAtmBkPvcVccIfB 3.1.1751.2.18.6.29.1.1
Interface index for side B, the atm side, of a backup bridge-atm DHPVC VCC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: read-write
OBJECT-TYPE    
  IntfIndex  

bridgeAtmBkPvcVccVpiB 3.1.1751.2.18.6.29.1.2
VPI value for side B, the atm side, of a backup bridge-atm DHPVC VCC connection. Valid range is a number between 0 and 4095.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

bridgeAtmBkPvcVccVciB 3.1.1751.2.18.6.29.1.3
VCI value for side B, the atm side, of a backup bridge-atm DHPVC VCC connection. Valid range is a number between 0 and 65535.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

bridgeAtmBkPvcVccActivePvc 3.1.1751.2.18.6.29.1.4
Current active PVC.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER primary(1), backup(2), none(3)  

bridgeAtmBkPvcVccAutoSwitch 3.1.1751.2.18.6.29.1.5
Auto switch back to primary link when primary link is recovered.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

bridgeAtmBkPvcVccRowStatus 3.1.1751.2.18.6.29.1.6
row status
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

bridgeAtmBkPvcVccViB 3.1.1751.2.18.6.29.1.7
VI to associate the Egress part of the A2B connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1024  

bridgeAtmBkPvcVccVUNIB 3.1.1751.2.18.6.29.1.8
VUNI to associate the Egress part of the A2B connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

bridgeAtmBkPvcVccConnFailureCauseB 3.1.1751.2.18.6.29.1.9
connection status reason code
Status: current Access: read-only
OBJECT-TYPE    
  AtmConnFailureCause  

ipAtmBkAppPvcVccTable 3.1.1751.2.18.6.30
This table is used to manage in-band management to atm DHPVC backup pvc.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IpAtmBkAppPvcVccEntry

ipAtmBkAppPvcVccEntry 3.1.1751.2.18.6.30.1
An entry in the in-band management to atm DHPVC table. There is one entry in the table corresponding to each active row in the ipAtmAppPvcVccTable for which the ipAtmAppPvcVccDualHomed object takes the value 'yes'.
Status: current Access: not-accessible
OBJECT-TYPE    
  IpAtmBkAppPvcVccEntry  

ipAtmBkAppPvcVccIfB 3.1.1751.2.18.6.30.1.1
Interface index for side B, the atm side, of a backup in-band management-atm DHPVC VCC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: read-write
OBJECT-TYPE    
  IntfIndex  

ipAtmBkAppPvcVccVpiB 3.1.1751.2.18.6.30.1.2
VPI value for side B, the atm side, of a backup in-band management-atm DHPVC VCC connection. Valid range is a number between 0 and 4095.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

ipAtmBkAppPvcVccVciB 3.1.1751.2.18.6.30.1.3
VCI value for side B, the atm side, of a backup in-band management-atm DHPVC VCC connection. Valid range is a number between 0 and 65535.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

ipAtmBkAppPvcVccActivePvc 3.1.1751.2.18.6.30.1.4
Current active PVC.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER primary(1), backup(2), none(3)  

ipAtmBkAppPvcVccAutoSwitch 3.1.1751.2.18.6.30.1.5
Auto switch back to primary link when primary link is recovered.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

ipAtmBkAppPvcVccRowStatus 3.1.1751.2.18.6.30.1.6
row status
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

ipAtmBkAppPvcVccViB 3.1.1751.2.18.6.30.1.7
VI to associate the Egress part of the A2B connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1024  

ipAtmBkAppPvcVccVUNIB 3.1.1751.2.18.6.30.1.8
VUNI to associate the Egress part of the A2B connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

ipAtmBkAppPvcVccConnFailureCauseB 3.1.1751.2.18.6.30.1.9
connection status reason code
Status: current Access: read-only
OBJECT-TYPE    
  AtmConnFailureCause  

spvcAddrTable 3.1.1751.2.18.6.31
Table of SPVC network interface addresses.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SpvcAddrEntry

spvcAddrEntry 3.1.1751.2.18.6.31.1
Row definition of SPVC address table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SpvcAddrEntry  

spvcAddrIfA 3.1.1751.2.18.6.31.1.1
Interface index for side A of an SPVC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

spvcAddrLocalPortAddr 3.1.1751.2.18.6.31.1.2
Local port NSAP address.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..20)  

spvcAddrRowStatus 3.1.1751.2.18.6.31.1.3
This is used to configure a NSAP address on the local port. Only when the address is configured can SPVC connections be established.
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

frAtmSpvcVccTable 3.1.1751.2.18.6.32
Table of frame relay to ATM IWF connections
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FrAtmSpvcVccEntry

frAtmSpvcVccEntry 3.1.1751.2.18.6.32.1
Row definition of frame relay to ATM IWF connections
Status: current Access: not-accessible
OBJECT-TYPE    
  FrAtmSpvcVccEntry  

frAtmSpvcVccDlciA 3.1.1751.2.18.6.32.1.1
DLCI value for side A, the frame relay side, of a frame relay-atm SPVC VCC connection. Valid range is a number between 0 and 1023.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..1023  

frAtmSpvcVccIfB 3.1.1751.2.18.6.32.1.2
Interface index for side B, the atm side, of a frame relay-atm SPVC VCC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: read-only
OBJECT-TYPE    
  IntfIndex  

frAtmSpvcVccVpiB 3.1.1751.2.18.6.32.1.3
VPI value for side B, the atm side, of a frame relay-atm SPVC VCC connection. Valid range is a number between 0 and 4095.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..4095  

frAtmSpvcVccVciB 3.1.1751.2.18.6.32.1.4
VCI value for side B, the atm side, of a frame relay-atm SPVC VCC connection. Valid range is a number between 0 and 65535.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

frAtmSpvcVccMaxFrameSizeIn 3.1.1751.2.18.6.32.1.5
The value of this object is the size in octets of the largest frame relay information field for this SPVC in the ingress direction (out of the frame relay UNI).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

frAtmSpvcVccBcIn 3.1.1751.2.18.6.32.1.6
The value of this object is equal to the committed burst size (Bc) parameter (measured in bits) for this SPVC in the ingress direction (into the frame relay UNI).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

frAtmSpvcVccBeIn 3.1.1751.2.18.6.32.1.7
The value of this object is equal to the excess burst size (Be) parameter (measured in bits) for this SPVC in the ingress direction (into the frame relay UNI).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

frAtmSpvcVccCirIn 3.1.1751.2.18.6.32.1.8
The value of this object is equal to the committed information rate (CIR) parameter (measured in bits per second) for this SPVC in the ingress direction (into the frame relay UNI).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

frAtmSpvcVccMaxFrameSizeOut 3.1.1751.2.18.6.32.1.9
The value of this object is the size in octets of the largest frame relay information field for this SPVC in the egress direction (out of the frame relay UNI).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

frAtmSpvcVccBcOut 3.1.1751.2.18.6.32.1.10
The value of this object is equal to the committed burst size (Bc) parameter (measured in bits) for this SPVC in the egress direction (into the frame relay UNI).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

frAtmSpvcVccBeOut 3.1.1751.2.18.6.32.1.11
The value of this object is equal to the excess burst size (Be) parameter (measured in bits) for this SPVC in the egress direction (into the frame relay UNI)
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

frAtmSpvcVccCirOut 3.1.1751.2.18.6.32.1.12
The value of this object is equal to the committed information rate (CIR) parameter (measured in bits per second) for this SPVC in the egress direction (into the frame relay UNI).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

frAtmSpvcVccServiceType 3.1.1751.2.18.6.32.1.13
service type, Frame relay traffic is carried by VBR type of service only.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ubr(1), vbr-nrt2(2), vbr-nrt1(3), vbr-rt2(4), vbr-rt1(5), vbr-express(6)  

frAtmSpvcVccFlow 3.1.1751.2.18.6.32.1.14
Flow Type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER duplex(1), simplexA2B(2), simplexB2A(3)  

frAtmSpvcVccTimeLenIn 3.1.1751.2.18.6.32.1.15
The time interval over which CIR and the burst sizes (Bc and Be) are measured in the A2B direction. The unit is milliseconds.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 64..4000  

frAtmSpvcVccTimeLenOut 3.1.1751.2.18.6.32.1.16
The time interval over which CIR and the burst sizes (Bc and Be) are measured in the A2B direction. The unit is milliseconds.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 64..4000  

frAtmSpvcVccPeakCellRateA2B 3.1.1751.2.18.6.32.1.17
Peak cell rate - side A, in cells per second, this will reflect the frame relay parameters in atm terms.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmSpvcVccSusCellRateA2B 3.1.1751.2.18.6.32.1.18
Sustained cell rate - side A, in cells per second, this will reflect the frame relay parameters in atm terms.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmSpvcVccMaxBurstSizeA2B 3.1.1751.2.18.6.32.1.19
Maximum burst size - side A, in cells, this will reflect the frame relay parameters in atm terms.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmSpvcVccPeakCellRateB2A 3.1.1751.2.18.6.32.1.20
Peak cell rate - side B, in cells per second, this will reflect the frame relay parameters in atm terms.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmSpvcVccSusCellRateB2A 3.1.1751.2.18.6.32.1.21
Sustained cell rate - side B, in cells per second, this will reflect the frame relay parameters in atm terms.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmSpvcVccMaxBurstSizeB2A 3.1.1751.2.18.6.32.1.22
Maximum burst size - side B, in cells, this will reflect the frame relay parameters in atm terms.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmSpvcVccInterWorkingFunc 3.1.1751.2.18.6.32.1.23
InterWorking function.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER frf8-Transl(1), frf8-Pass(2), frf5(3)  

frAtmSpvcVccConnType 3.1.1751.2.18.6.32.1.24
The type of connection: activeSvc - attempt calls, whenever not established; passiveSvc - accepts calls
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER activeSvc(1), passiveSvc(2)  

frAtmSpvcVccOperStatus 3.1.1751.2.18.6.32.1.25
other - none of the types specified below; establishmentInProgress - connection is not operational, but call attempts are ongoing; connected - connection is currently operational; retriesExhausted - retry limit has been reached and call attempts have ceased; noAddressSupplied - no remote address has been configured, so no call attempts are initiated; lowerLayerDown - SPVC handler is not operational.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER other(1), establishmentInProgress(2), connected(3), retriesExhausted(4), noAddressSupplied(5), lowerLayerDown(6), waitingForCall(7), waitingForRetryTimer(8)  

frAtmSpvcVccRowStatus 3.1.1751.2.18.6.32.1.26
row status
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

frAtmSpvcVccRemoteFrPortAddr 3.1.1751.2.18.6.32.1.27
The ATM address supporting the corresponding far end FR IWF process. If no address is supplied, no attempts to establish the active SVC are initiated.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..20)  

frAtmSpvcVccRemoteSelectType 3.1.1751.2.18.6.32.1.28
Indicates whether the remote DLCI/VPI/VCI values are to be used at the destination. If 'any' is used, the destination switch will choose the DLCI/VPI/VCI values. In such a case, once the SPVC is connected, the value of this object will change to 'required', such that the same DLCI/VPI/VCI values will continue to be used even if the connection is torn down and re-established. If the value 'required' is specified, the values: frAtmSpvcVccRemoteDlci or frAtmSpvcVccRemoteVpi and frAtmSpvcVccRemoteVci, must be supplied and are used at the destination.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER required(1), any(2)  

frAtmSpvcVccRemoteDlci 3.1.1751.2.18.6.32.1.29
DLCI value to be used at the destination of an ATM SPVC VCC connection. Valid range is a number between 0 and 4095. If frAtmSpvcVccRemoteSelectType is configured as 'any', then this value is not relevant.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

frAtmSpvcVccRemoteVpi 3.1.1751.2.18.6.32.1.30
VPI value to be used at the destination of an ATM SPVC VCC connection. Valid range is a number between 0 and 4095. If frAtmSpvcVccRemoteSelectType is configured as 'any', then this value is not relevant.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

frAtmSpvcVccRemoteVci 3.1.1751.2.18.6.32.1.31
VCI value to be used at the destination of an ATM SPVC VCC connection. Valid range is a number between 0 and 65535. If frAtmSpvcVccRemoteSelectType is configured as 'any', then this value is not relevant.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

frAtmSpvcVccRetryInterval 3.1.1751.2.18.6.32.1.32
The time to wait before attempting to establish the SVC after previous failed call attempt. 0 indicates retry will be attempted immediately.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..3600  

frAtmSpvcVccRetryLimit 3.1.1751.2.18.6.32.1.33
A maximum limit on how many retries. 0 indicates no limit.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

frAtmSpvcVccRestart 3.1.1751.2.18.6.32.1.34
restart, the active SVC is released if necessary and a new setup procedure is begun; or noop
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER restart(1), noop(2)  

frAtmSpvcVccRetryFailure 3.1.1751.2.18.6.32.1.35
Indicates how many attempts to establish the connection have failed. It is reset whenever a connection is successfully established or the SVC is restarted.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmSpvcVccReleaseCause 3.1.1751.2.18.6.32.1.36
CAUSE field value of the last RELEASE message received for this SVC.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..127  

frAtmSpvcVccReleaseDiag 3.1.1751.2.18.6.32.1.37
DIAGNOSTICS field value of the last RELEASE message received for this SVC.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..8)  

frAtmSpvcVccRelease 3.1.1751.2.18.6.32.1.38
Release the connnection established on the endpoint and if the endpoint is Active, do not retry.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER release(1), noop(2)  

frAtmSpvcVccStatsCellsEncodedHiA 3.1.1751.2.18.6.32.1.39
Cells encoded on side A- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmSpvcVccStatsCellsEncodedLoA 3.1.1751.2.18.6.32.1.40
Cells encoded on side A- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmSpvcVccStatsCellsDecodedHiA 3.1.1751.2.18.6.32.1.41
Cells decoded on side A- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmSpvcVccStatsCellsDecodedLoA 3.1.1751.2.18.6.32.1.42
Cells decoded on side A- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmSpvcVccStatsInCellCountHiB 3.1.1751.2.18.6.32.1.43
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmSpvcVccStatsInCellCountLoB 3.1.1751.2.18.6.32.1.44
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmSpvcVccStatsOutCellCountHiB 3.1.1751.2.18.6.32.1.45
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmSpvcVccStatsOutCellCountLoB 3.1.1751.2.18.6.32.1.46
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmSpvcVccStatsTimer 3.1.1751.2.18.6.32.1.47
Number of seconds stats have been collecting
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmSpvcVccStatsFramesDroppedA 3.1.1751.2.18.6.32.1.48
Number of frames dropped for a given DLCI for A2B direction, only applicable to the input side.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmSpvcVccStatsOdometerCellsEncodedHiA 3.1.1751.2.18.6.32.1.49
Cells encoded on side A- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmSpvcVccStatsOdometerCellsEncodedLoA 3.1.1751.2.18.6.32.1.50
Cells encoded on side A- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmSpvcVccStatsOdometerCellsDecodedHiA 3.1.1751.2.18.6.32.1.51
Cells decoded on side A- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmSpvcVccStatsOdometerCellsDecodedLoA 3.1.1751.2.18.6.32.1.52
Cells decoded on side A- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmSpvcVccStatsInOdometerCellCountHiB 3.1.1751.2.18.6.32.1.53
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmSpvcVccStatsInOdometerCellCountLoB 3.1.1751.2.18.6.32.1.54
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmSpvcVccStatsOutOdometerCellCountHiB 3.1.1751.2.18.6.32.1.55
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmSpvcVccStatsOutOdometerCellCountLoB 3.1.1751.2.18.6.32.1.56
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmSpvcVccStatsOdometerTimer 3.1.1751.2.18.6.32.1.57
Number of seconds since odometer was reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmSpvcVccStatsOdometerReset 3.1.1751.2.18.6.32.1.58
Odometer reset button.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reset(1)  

frAtmSpvcVccStatsAal5ErrFramesA 3.1.1751.2.18.6.32.1.59
Number of Aal5 Errored Frames, which are not dropped due to UPC in A2B dir, only applicable to Input Side
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmSpvcVccStatsFramesTaggedA 3.1.1751.2.18.6.32.1.60
Number of Frames tagged due to UPC in A2B dir, only applicable to Input Side
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmSpvcVccStatsCellsDroppedB 3.1.1751.2.18.6.32.1.61
Cells Dropped on the Incoming side of B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmSpvcVccStatsCellsTaggedB 3.1.1751.2.18.6.32.1.62
Cells Tagged on the Incoming side of B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmSpvcVccVUNIB 3.1.1751.2.18.6.32.1.63
VUNI to associate the Egress part of the B2A connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

frAtmSpvcVccTrafficShapingA2B 3.1.1751.2.18.6.32.1.64
Traffic Shaping Support in the A2B direction.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

frAtmSpvcVccPriority 3.1.1751.2.18.6.32.1.65
Priority of SPVC - priority-1 being highest priority .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER priority-1(1), priority-2(2), priority-3(3), priority-4(4)  

atmAtmSpvcVccTable 3.1.1751.2.18.6.33
Table of SPVC ATM virtual channel connections.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmAtmSpvcVccEntry

atmAtmSpvcVccEntry 3.1.1751.2.18.6.33.1
Row definition of ATM SPVC VCC connections.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmAtmSpvcVccEntry  

atmAtmSpvcVccVpiA 3.1.1751.2.18.6.33.1.1
VPI value for side A of an ATM SPVC VCC connection. Valid range is a number between 0 and 4095.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..4095  

atmAtmSpvcVccVciA 3.1.1751.2.18.6.33.1.2
VCI value for side A of an ATM SPVC VCC connection. Valid range is a number between 0 and 65535.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..65535  

atmAtmSpvcVccRemoteAtmPortAddr 3.1.1751.2.18.6.33.1.3
Remote ATM port NSAP address, not meaningful if passive type of connection.
Status: current Access: not-accessible
OBJECT-TYPE    
  OCTET STRING Size(1..20)  

atmAtmSpvcVccIfB 3.1.1751.2.18.6.33.1.4
Interface index for side B of an ATM SPVC VCC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: read-only
OBJECT-TYPE    
  IntfIndex  

atmAtmSpvcVccVpiB 3.1.1751.2.18.6.33.1.5
VPI value for side B of an ATM SPVC VCC connection. Valid range is a number between 0 and 4095.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..4095  

atmAtmSpvcVccVciB 3.1.1751.2.18.6.33.1.6
VCI value for side B of an ATM SPVC VCC connection. Valid range is a number between 0 and 65535.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

atmAtmSpvcVccServiceTypeA2B 3.1.1751.2.18.6.33.1.7
Service type, ATM port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ubr(1), vbr-nrt2(2), vbr-nrt1(3), vbr-rt2(4), vbr-rt1(5), vbr-express(6), cbr4(7), cbr3(8), cbr2(9)  

atmAtmSpvcVccSarTypeA2B 3.1.1751.2.18.6.33.1.8
SAR type used in ATM adaption, ATM port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER aal5(1), aal3-4(2), aal2(3), aal1(4), null(5)  

atmAtmSpvcVccPeakCellRateA2B 3.1.1751.2.18.6.33.1.9
Peak cell rate - side A, ATM port, in cells per second.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVccSusCellRateA2B 3.1.1751.2.18.6.33.1.10
Sustained cell rate - side A, ATM port, in cells per second.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVccMaxBurstSizeA2B 3.1.1751.2.18.6.33.1.11
Maximum burst size - side A, ATM port, in cells per second.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVccFrwdErrCorrectionA2B 3.1.1751.2.18.6.33.1.12
Forward error correction scheme, ATM port side.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), eighthRate(2), quarterRate(3), halfRate(4), autoHiQ(5), auto(6), autoLoQ(7)  

atmAtmSpvcVccServiceTypeB2A 3.1.1751.2.18.6.33.1.13
Service type, ATM trunk side.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ubr(1), vbr-nrt2(2), vbr-nrt1(3), vbr-rt2(4), vbr-rt1(5), vbr-express(6), cbr4(7), cbr3(8), cbr2(9)  

atmAtmSpvcVccSarTypeB2A 3.1.1751.2.18.6.33.1.14
SAR type used in ATM adaption, ATM trunk side.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER aal5(1), aal3-4(2), aal2(3), aal1(4), null(5)  

atmAtmSpvcVccPeakCellRateB2A 3.1.1751.2.18.6.33.1.15
Peak cell rate - side B, ATM trunk, in cells per second.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVccSusCellRateB2A 3.1.1751.2.18.6.33.1.16
Sustained cell rate - side B, ATM trunk, in cells per second.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVccMaxBurstSizeB2A 3.1.1751.2.18.6.33.1.17
Maximum burst size - side A, ATM trunk, in cells per second.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVccFrwdErrCorrectionB2A 3.1.1751.2.18.6.33.1.18
Forward error correction scheme, ATM trunk side.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), eighthRate(2), quarterRate(3), halfRate(4), autoHiQ(5), auto(6), autoLoQ(7)  

atmAtmSpvcVccFlow 3.1.1751.2.18.6.33.1.19
Type of flow, pointToMultipointA2B is for future support.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER duplex(1), simplexA2B(2), pointToMultipointA2B(3), simplexB2A(4), pointToMultipointB2A(5)  

atmAtmSpvcVccType 3.1.1751.2.18.6.33.1.20
Type of connection.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER nonsecured(1), secured(2)  

atmAtmSpvcVccConnType 3.1.1751.2.18.6.33.1.21
The type of connection: activeSvc - attempt calls, whenever not established. passiveSvc - accept calls.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER activeSvc(1), passiveSvc(2)  

atmAtmSpvcVccLeafReference 3.1.1751.2.18.6.33.1.22
An arbitrary integer which serves to distinguish the mulitple leaves attached to a root of a point-to-multipoint SPVC. If point-to-point SPVC, the value should be 1.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

atmAtmSpvcVccOperStatus 3.1.1751.2.18.6.33.1.23
The operation status of the connection: other - none of the types specified below. establishmentInProgress - connection is not operational, but call attempts are ongoing. connected - connection is currently operational. retriesExhausted - retry limit has been reached and call attempts have ceased. noAddressSupplied - no remote address has been configured, so no call attempts are initiated. lowerLayerDown - SPVC handler is not operational.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER other(1), establishmentInProgress(2), connected(3), retriesExhausted(4), noAddressSupplied(5), lowerLayerDown(6), waitingForCall(7), waitingForRetryTimer(8)  

atmAtmSpvcVccRowStatus 3.1.1751.2.18.6.33.1.24
Used to create and delete a soft PVC. When this object is set to 'active', an attempt is made to set up the soft PVC. When this object has the value 'active' and is set to another value, any setup or connection in-progress is released.
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

atmAtmSpvcVccRemoteSelectType 3.1.1751.2.18.6.33.1.25
Indicates whether the remote VPI/VCI values are to be used at the destination. If 'any' is used, the destination switch will choose the VPI/VCI values. In such a case, once the SPVC is connected, the value of this object will change to 'required', such that the same VPI/VCI values will continue to be used even if the connection is torn down and re-established. If the value 'required' is specified, the values: atmAtmSpvcVccRemoteVpi and atmAtmSpvcVccRemoteVci, must be supplied and are used at the destination.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER required(1), any(2)  

atmAtmSpvcVccRemoteVpi 3.1.1751.2.18.6.33.1.26
VPI value to be used at the destination of an ATM SPVC VCC connection. Valid range is a number between 0 and 4095. If atmAtmSpvcVccRemoteSelectType is configured as 'any', then this value is not relevant.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

atmAtmSpvcVccRemoteVci 3.1.1751.2.18.6.33.1.27
VCI value to be used at the destination of an ATM SPVC VCC connection. Valid range is a number between 0 and 65535. If atmAtmSpvcVccRemoteSelectType is configured as 'any', then this value is not relevant.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

atmAtmSpvcVccRetryInterval 3.1.1751.2.18.6.33.1.28
The time to wait before attempting to establish the SVC after a previous failed call attempt. A value of 0 indicates retries will be attempted immediately.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..3600  

atmAtmSpvcVccRetryLimit 3.1.1751.2.18.6.33.1.29
A maximum limit on how many retries should be attempted. A value of 0 indicates no limit.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

atmAtmSpvcVccRestart 3.1.1751.2.18.6.33.1.30
The active SVC is released, if necessary, and a new setup procedure is begun if 'restart', otherwise, noop.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER restart(1), noop(2)  

atmAtmSpvcVccRetryFailure 3.1.1751.2.18.6.33.1.31
Indicates how many attempts to establish the connection have failed. It it reset whenever a connection is successfully established or the SVC is restarted.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVccReleaseCause 3.1.1751.2.18.6.33.1.32
CAUSE field value of the last RELEASE message received for this SVC.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..127  

atmAtmSpvcVccReleaseDiag 3.1.1751.2.18.6.33.1.33
DIAGNOSTICS field value of the last RELEASE message received for this SVC.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..8)  

atmAtmSpvcVccRelease 3.1.1751.2.18.6.33.1.34
Release the connnection established on the endpoint and if the endpoint is Active, do not retry.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER release(1), noop(2)  

atmAtmSpvcVccStatsInCellCountHiA 3.1.1751.2.18.6.33.1.35
Valid Cells received on A - (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVccStatsInCellCountLoA 3.1.1751.2.18.6.33.1.36
Valid Cells received on A - (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVccStatsOutCellCountHiA 3.1.1751.2.18.6.33.1.37
Valid cells transmitted on A -(High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVccStatsOutCellCountLoA 3.1.1751.2.18.6.33.1.38
Valid cells transmitted on A -(Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVccStatsInCellCountHiB 3.1.1751.2.18.6.33.1.39
Valid Cells received on B - (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVccStatsInCellCountLoB 3.1.1751.2.18.6.33.1.40
Valid Cells received on B - (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVccStatsOutCellCountHiB 3.1.1751.2.18.6.33.1.41
Valid cells transmitted on B -(High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVccStatsOutCellCountLoB 3.1.1751.2.18.6.33.1.42
Valid cells transmitted on B -(Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVccStatsTimer 3.1.1751.2.18.6.33.1.43
Number of seconds stats have been collecting
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVccStatsFrwdErrCrrctnRateA2B 3.1.1751.2.18.6.33.1.44
Displays the Forward error correction rate being used by the FEC module in the A2B direction. This field is dynamic when Auto rates are selected. In other cases, it will display the rate set by the user.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), eighthRate(2), quarterRate(3), halfRate(4)  

atmAtmSpvcVccStatsFrwdErrCrrctnRateB2A 3.1.1751.2.18.6.33.1.45
Displays the Forward error correction rate being used by the FEC module in the B2A direction. This field is dynamic when Auto rates are selected. In other cases, it will display the rate set by the user.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), eighthRate(2), quarterRate(3), halfRate(4)  

atmAtmSpvcVccStatsInOdometerCellCountHiA 3.1.1751.2.18.6.33.1.46
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVccStatsInOdometerCellCountLoA 3.1.1751.2.18.6.33.1.47
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVccStatsOutOdometerCellCountHiA 3.1.1751.2.18.6.33.1.48
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVccStatsOutOdometerCellCountLoA 3.1.1751.2.18.6.33.1.49
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVccStatsInOdometerCellCountHiB 3.1.1751.2.18.6.33.1.50
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVccStatsInOdometerCellCountLoB 3.1.1751.2.18.6.33.1.51
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVccStatsOutOdometerCellCountHiB 3.1.1751.2.18.6.33.1.52
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVccStatsOutOdometerCellCountLoB 3.1.1751.2.18.6.33.1.53
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVccStatsOdometerTimer 3.1.1751.2.18.6.33.1.54
Number of seconds since odometer was reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVccStatsOdometerReset 3.1.1751.2.18.6.33.1.55
Odometer reset button.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reset(1)  

atmAtmSpvcVccViA 3.1.1751.2.18.6.33.1.56
VI to associate the Egress part of the B2A connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1024  

atmAtmSpvcVccViB 3.1.1751.2.18.6.33.1.57
VI to associate the Egress part of the A2B connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1024  

atmAtmSpvcVccStatsCellsDroppedA 3.1.1751.2.18.6.33.1.58
Cells Dropped on the Incoming side of A
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVccStatsCellsTaggedA 3.1.1751.2.18.6.33.1.59
Cells Tagged on the Incoming side of A
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVccStatsCellsDroppedB 3.1.1751.2.18.6.33.1.60
Cells Dropped on the Incoming side of B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVccStatsCellsTaggedB 3.1.1751.2.18.6.33.1.61
Cells Tagged on the Incoming side of B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVccVUNIA 3.1.1751.2.18.6.33.1.62
VUNI to associate the Egress part of the B2A connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

atmAtmSpvcVccVUNIB 3.1.1751.2.18.6.33.1.63
VUNI to associate the Egress part of the A2B connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

atmAtmSpvcVccTrafficShapingA2B 3.1.1751.2.18.6.33.1.64
Traffic Shaping Support in the A2B direction.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

atmAtmSpvcVccTrafficShapingB2A 3.1.1751.2.18.6.33.1.65
Traffic Shaping Support in the B2A direction.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

atmAtmSpvcVccPriority 3.1.1751.2.18.6.33.1.66
Priority of SPVC - priority-1 being highest priority .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER priority-1(1), priority-2(2), priority-3(3), priority-4(4)  

cirAtmSpvcVccTable 3.1.1751.2.18.6.34
Table of Circuit Emulation to ATM Soft PVCs.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CirAtmSpvcVccEntry

cirAtmSpvcVccEntry 3.1.1751.2.18.6.34.1
Row definition of circuit emulation to ATM SPVC connections.
Status: current Access: not-accessible
OBJECT-TYPE    
  CirAtmSpvcVccEntry  

cirAtmSpvcVccRemoteCePortAddr 3.1.1751.2.18.6.34.1.1
The ATM address supporting the corresponding far end CES IWF process. If no address is supplied, no attempts to establish the active SVC are initiated.
Status: current Access: not-accessible
OBJECT-TYPE    
  OCTET STRING Size(1..20)  

cirAtmSpvcVccIfB 3.1.1751.2.18.6.34.1.2
Interface index for side B, the atm side, of a circuit emulation-atm SPVC VCC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: read-only
OBJECT-TYPE    
  IntfIndex  

cirAtmSpvcVccVpiB 3.1.1751.2.18.6.34.1.3
VPI value for side B, the atm side, of a circuit emulation-atm SPVC VCC connection. Valid range is a number between 0 and 4095.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..4095  

cirAtmSpvcVccVciB 3.1.1751.2.18.6.34.1.4
VCI value for side B, the atm side, of a circuit emulation-atm SPVC VCC connection. Valid range is a number between 0 and 65535.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

cirAtmSpvcVccVoiceCompressionA2B 3.1.1751.2.18.6.34.1.5
Voice Compression Algorithm
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), g726-16k(2), g726-24k(3), g726-32k(4), g726-40k(5), g729a-8k(6)  

cirAtmSpvcVccSilenceDetectionA2B 3.1.1751.2.18.6.34.1.6
silence detection off/on
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

cirAtmSpvcVccEchoCancellationA2B 3.1.1751.2.18.6.34.1.7
Echo Cancellation Algorithm
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), g165-nearEnd(2), g168(3)  

cirAtmSpvcVccCngToneDetectionA2B 3.1.1751.2.18.6.34.1.8
Calling Tone Detection Algorithm, one of the enum value, g726-32k(3) is obsoleted on 01Mar99 such that user would not be able to configure CE-ATM
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), bypass(2), g726-32k(3)  

cirAtmSpvcVccCodingTranslationA2B 3.1.1751.2.18.6.34.1.9
Coding rule translation type.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), muLaw2muLaw(2), aLaw2aLaw(3), muLaw2aLaw(4), aLaw2muLaw(5)  

cirAtmSpvcVccVoiceCompressionB2A 3.1.1751.2.18.6.34.1.10
Voice Compression Algorithm
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), g726-16k(2), g726-24k(3), g726-32k(4), g726-40k(5), g729a-8k(6)  

cirAtmSpvcVccSilenceDetectionB2A 3.1.1751.2.18.6.34.1.11
silence detection off/on
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

cirAtmSpvcVccEchoCancellationB2A 3.1.1751.2.18.6.34.1.12
Echo Cancellation Algorithm
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), g165-nearEnd(2), g168(3)  

cirAtmSpvcVccCngToneDetectionB2A 3.1.1751.2.18.6.34.1.13
Calling Tone Detection Algorithm, one of the enum value, g726-32k(3) is obsoleted on 01Mar99 such that user would not be able to configure CE-ATM
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), bypass(2), g726-32k(3)  

cirAtmSpvcVccCodingTranslationB2A 3.1.1751.2.18.6.34.1.14
Coding rule translation type.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), muLaw2muLaw(2), aLaw2aLaw(3), muLaw2aLaw(4), aLaw2muLaw(5)  

cirAtmSpvcVccFlow 3.1.1751.2.18.6.34.1.15
Flow Type, pointToMultipointA2B and pointToMultipointB2A are for future support.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER duplex(1), simplexA2B(2), simplexB2A(3), pointToMultipointA2B(4), pointToMultipointB2A(5)  

cirAtmSpvcVccServiceType 3.1.1751.2.18.6.34.1.16
service type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER cbr-2(2), cbr-3(3), cbr-4(4)  

cirAtmSpvcVccConnType 3.1.1751.2.18.6.34.1.17
The type of connection: activeSvc - attempt calls, whenever not established; passiveSvc - accepts calls
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER activeSvc(1), passiveSvc(2)  

cirAtmSpvcVccOperStatus 3.1.1751.2.18.6.34.1.18
other - none of the types specified below; establishmentInProgress - connection is not operational, but call attempts are ongoing; connected - connection is currently operational; retriesExhausted - retry limit has been reached and call attempts have ceased; noAddressSupplied - no remote address has been configured, so no call attempts are initiated; lowerLayerDown - SPVC handler is not operational.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER other(1), establishmentInProgress(2), connected(3), retriesExhausted(4), noAddressSupplied(5), lowerLayerDown(6), waitingForCall(7), waitingForRetryTimer(8)  

cirAtmSpvcVccRowStatus 3.1.1751.2.18.6.34.1.19
Used to create and delete a soft PVCC. When this object is set to 'active' an attempt is made to set up the soft PVCC. When this object has the value 'active' and is set to another value, any set-up or connection in-progess is released.
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

cirAtmSpvcVccViB 3.1.1751.2.18.6.34.1.20
VI to associate the Egress part of the B2A connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1024  

cirAtmSpvcVccRetryInterval 3.1.1751.2.18.6.34.1.21
The time to wait before attempting to establish the SVC after previous failed call attempt. 0 indicates retries will be attempted immediately.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..3600  

cirAtmSpvcVccRetryLimit 3.1.1751.2.18.6.34.1.22
A maximum limit on how many retries. 0 indicates no limit.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

cirAtmSpvcVccRestart 3.1.1751.2.18.6.34.1.23
restart, the active SVC is released if necessary and a new setup procedure is begun; or noop
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER restart(1), noop(2)  

cirAtmSpvcVccRetryFailure 3.1.1751.2.18.6.34.1.24
Indicates how many attempts to establish the connection have failed. It is reset whenever a connection is successfully established or the SVC is restarted.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirAtmSpvcVccReleaseCause 3.1.1751.2.18.6.34.1.25
CAUSE field value of the last RELEASE message received for this SVC.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..127  

cirAtmSpvcVccReleaseDiag 3.1.1751.2.18.6.34.1.26
DIAGNOSTICS field value of the last RELEASE message received for this SVC.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..8)  

cirAtmSpvcVccRelease 3.1.1751.2.18.6.34.1.27
Release the connnection established on the endpoint and if the endpoint is Active, do not retry.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER release(1), noop(2)  

cirAtmSpvcVccStatsCellsEncodedHiA 3.1.1751.2.18.6.34.1.28
Cells encoded on side A- (High order portion )
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirAtmSpvcVccStatsCellsEncodedLoA 3.1.1751.2.18.6.34.1.29
Cells encoded on side A - ( Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirAtmSpvcVccStatsCellsDecodedHiA 3.1.1751.2.18.6.34.1.30
Cells decoded on side A - ( High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirAtmSpvcVccStatsCellsDecodedLoA 3.1.1751.2.18.6.34.1.31
Cells decoded on side A - (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirAtmSpvcVccStatsInCellCountHiB 3.1.1751.2.18.6.34.1.32
Valid Cells received on B - (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirAtmSpvcVccStatsInCellCountLoB 3.1.1751.2.18.6.34.1.33
Valid Cells received on B - (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirAtmSpvcVccStatsOutCellCountHiB 3.1.1751.2.18.6.34.1.34
Valid cells transmitted on B- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirAtmSpvcVccStatsOutCellCountLoB 3.1.1751.2.18.6.34.1.35
Valid cells transmitted on B -(Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirAtmSpvcVccStatsTimer 3.1.1751.2.18.6.34.1.36
Number of seconds since stats have been collecting
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirAtmSpvcVccStatsOdometerCellsEncodedHiA 3.1.1751.2.18.6.34.1.37
Cells encoded on side A- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirAtmSpvcVccStatsOdometerCellsEncodedLoA 3.1.1751.2.18.6.34.1.38
Cells encoded on side A- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirAtmSpvcVccStatsOdometerCellsDecodedHiA 3.1.1751.2.18.6.34.1.39
Cells decoded on side A- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirAtmSpvcVccStatsOdometerCellsDecodedLoA 3.1.1751.2.18.6.34.1.40
Cells decoded on side A- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirAtmSpvcVccStatsInOdometerCellCountHiB 3.1.1751.2.18.6.34.1.41
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirAtmSpvcVccStatsInOdometerCellCountLoB 3.1.1751.2.18.6.34.1.42
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirAtmSpvcVccStatsOutOdometerCellCountHiB 3.1.1751.2.18.6.34.1.43
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirAtmSpvcVccStatsOutOdometerCellCountLoB 3.1.1751.2.18.6.34.1.44
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirAtmSpvcVccStatsOdometerTimer 3.1.1751.2.18.6.34.1.45
Number of seconds since odometer was reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirAtmSpvcVccStatsOdometerReset 3.1.1751.2.18.6.34.1.46
Odometer reset button.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reset(1)  

cirAtmSpvcVccStatsCellsDroppedB 3.1.1751.2.18.6.34.1.47
Cells Dropped on the Incoming side of B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirAtmSpvcVccStatsCellsTaggedB 3.1.1751.2.18.6.34.1.48
Cells Tagged on the Incoming side of B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirAtmSpvcVccVUNIB 3.1.1751.2.18.6.34.1.49
VUNI to associate the Egress part of the B2A connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

cirAtmSpvcVccSarTypeB 3.1.1751.2.18.6.34.1.50
This field will only be used when selecting voice compression, in other cases it will be set to aal1.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER aal1(1), aal2(2)  

cirAtmSpvcVccPriority 3.1.1751.2.18.6.34.1.51
Priority of SPVC - priority-1 being highest priority .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER priority-1(1), priority-2(2), priority-3(3), priority-4(4)  

vbrAtmSpvcTable 3.1.1751.2.18.6.35
Table of SPVC atm virtual channel connections
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VbrAtmSpvcEntry

vbrAtmSpvcEntry 3.1.1751.2.18.6.35.1
Row definition of atm SPVC VCC connections
Status: current Access: not-accessible
OBJECT-TYPE    
  VbrAtmSpvcEntry  

vbrAtmSpvcRemoteVbrPortAddr 3.1.1751.2.18.6.35.1.1
remote VBR port nsap address implemening IWF, not meaningful if passive type of connection
Status: current Access: not-accessible
OBJECT-TYPE    
  OCTET STRING Size(1..20)  

vbrAtmSpvcIfB 3.1.1751.2.18.6.35.1.2
Interface index for side B, the atm side, of a variable bit rate-atm SPVC VCC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: read-only
OBJECT-TYPE    
  IntfIndex  

vbrAtmSpvcVpiB 3.1.1751.2.18.6.35.1.3
VPI value for side B, the atm side, of a variable bit rate-atm SPVC VCC connection. Valid range is a number between 0 and 4095.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..4095  

vbrAtmSpvcVciB 3.1.1751.2.18.6.35.1.4
VCI value for side B, the atm side, of a variable bit rate-atm SPVC VCC connection. Valid range is a number between 0 and 65535.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

vbrAtmSpvcServiceType 3.1.1751.2.18.6.35.1.5
service type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ubr(1), vbr-nrt1(2), vbr-nrt2(3), vbr-rt1(4), vbr-rt2(5), vbr-express(6)  

vbrAtmSpvcPeakCellRateA2B 3.1.1751.2.18.6.35.1.6
peak cell rate - side A, in cell per second
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcSusCellRateA2B 3.1.1751.2.18.6.35.1.7
sustained rate - side A, in cell per second
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcMaxBurstSizeA2B 3.1.1751.2.18.6.35.1.8
maximum burst size - side A, in cells
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcPeakCellRateB2A 3.1.1751.2.18.6.35.1.9
peak rate - side B, ATM trunk, in cell per second.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcSusCellRateB2A 3.1.1751.2.18.6.35.1.10
sustained rate - side B, ATM trunk, in cell per second.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcMaxBurstSizeB2A 3.1.1751.2.18.6.35.1.11
maximum burst size - side B, ATM trunk, in cells.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcFlow 3.1.1751.2.18.6.35.1.12
type of flow
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER duplex(1), simplexA2B(2), simplexB2A(3)  

vbrAtmSpvcConnType 3.1.1751.2.18.6.35.1.13
The type of connection: activeSvc - attempt calls, whenever not established; passiveSvc - accepts calls
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER activeSvc(1), passiveSvc(2)  

vbrAtmSpvcOperStatus 3.1.1751.2.18.6.35.1.14
other - none of the types specified below; establishmentInProgress - connection is not operational, but call attempts are ongoing; connected - connection is currently operational; retriesExhausted - retry limit has been reached and call attempts have ceased; noAddressSupplied - no remote address has been configured, so no call attempts are initiated; lowerLayerDown - SPVC handler is not operational.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER other(1), establishmentInProgress(2), connected(3), retriesExhausted(4), noAddressSupplied(5), lowerLayerDown(6), waitingForCall(7), waitingForRetryTimer(8)  

vbrAtmSpvcRowStatus 3.1.1751.2.18.6.35.1.15
Used to create and delete a soft PVCC. When this object is set to 'active' an attempt is made to set up the soft PVCC. When this object has the value 'active' and is set to another value, any set-up or connection in-progess is released.
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

vbrAtmSpvcViB 3.1.1751.2.18.6.35.1.16
VI to associate the Egress part of the B2A connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1024  

vbrAtmSpvcRetryInterval 3.1.1751.2.18.6.35.1.17
the time to wait before attempting to establish the SVC after previous failed call attempt. 0 indicates retries will be attempted immediately.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..3600  

vbrAtmSpvcRetryLimit 3.1.1751.2.18.6.35.1.18
a maximum limit on how many retries. 0 indicates no limit.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

vbrAtmSpvcRestart 3.1.1751.2.18.6.35.1.19
restart, the active SVC is released if necessary and a new setup procedure is begun; or noop
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER restart(1), noop(2)  

vbrAtmSpvcRetryFailure 3.1.1751.2.18.6.35.1.20
indicates how many attempts to establish the connection have failed. It is reset whenever a connection is successfully established or the SVC is restarted.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcReleaseCause 3.1.1751.2.18.6.35.1.21
CAUSE field value of the last RELEASE message received for this SVC
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..127  

vbrAtmSpvcReleaseDiag 3.1.1751.2.18.6.35.1.22
DIAGNOSTICS field value of the last RELEASE message received for this SVC
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..8)  

vbrAtmSpvcRelease 3.1.1751.2.18.6.35.1.23
Release the connnection established on the endpoint and if the endpoint is Active, do not retry.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER release(1), noop(2)  

vbrAtmSpvcStatsCellsEncodedHiA 3.1.1751.2.18.6.35.1.24
Cells encoded on side A- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcStatsCellsEncodedLoA 3.1.1751.2.18.6.35.1.25
ells encoded on side A - (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcStatsCellsDecodedHiA 3.1.1751.2.18.6.35.1.26
Cells decoded on side A - (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcStatsCellsDecodedLoA 3.1.1751.2.18.6.35.1.27
Cells decoded on side A - (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcStatsInCellCountHiB 3.1.1751.2.18.6.35.1.28
Valid Cells received on B - (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcStatsInCellCountLoB 3.1.1751.2.18.6.35.1.29
Valid Cells received on B - (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcStatsOutCellCountHiB 3.1.1751.2.18.6.35.1.30
Valid cells transmitted on B -(High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcStatsOutCellCountLoB 3.1.1751.2.18.6.35.1.31
Valid cells transmitted on B - (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcStatsTimer 3.1.1751.2.18.6.35.1.32
Number of seconds stats have been collecting
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcStatsOdometerCellsEncodedHiA 3.1.1751.2.18.6.35.1.33
Cells encoded on side A- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcStatsOdometerCellsEncodedLoA 3.1.1751.2.18.6.35.1.34
Cells encoded on side A- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcStatsOdometerCellsDecodedHiA 3.1.1751.2.18.6.35.1.35
Cells decoded on side A- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcStatsOdometerCellsDecodedLoA 3.1.1751.2.18.6.35.1.36
Cells decoded on side A- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcStatsInOdometerCellCountHiB 3.1.1751.2.18.6.35.1.37
Valid Cells received on B - (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcStatsInOdometerCellCountLoB 3.1.1751.2.18.6.35.1.38
Valid Cells received on B - (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcStatsOutOdometerCellCountHiB 3.1.1751.2.18.6.35.1.39
Valid Cells transmitted on B -(High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcStatsOutOdometerCellCountLoB 3.1.1751.2.18.6.35.1.40
Valid Cells transmitted on B -(Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcStatsOdometerTimer 3.1.1751.2.18.6.35.1.41
Number of seconds since odometer was reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcStatsOdometerReset 3.1.1751.2.18.6.35.1.42
Odometer reset button.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reset(1)  

vbrAtmSpvcStatsCellsDroppedB 3.1.1751.2.18.6.35.1.43
Cells Dropped on the Incoming side of B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcStatsCellsTaggedB 3.1.1751.2.18.6.35.1.44
Cells Tagged on the Incoming side of B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcVUNIB 3.1.1751.2.18.6.35.1.45
VUNI to associate the Egress part of the B2A connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

vbrAtmSpvcTrafficShapingA2B 3.1.1751.2.18.6.35.1.46
Traffic Shaping Support in the A2B direction.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

vbrAtmSpvcPriority 3.1.1751.2.18.6.35.1.47
Priority of SPVC - priority-1 being highest priority .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER priority-1(1), priority-2(2), priority-3(3), priority-4(4)  

aal2TrunkConfigTable 3.1.1751.2.18.6.36
Table of terminal emulation to ATM network IWF connections
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Aal2TrunkConfigEntry

aal2TrunkConfigEntry 3.1.1751.2.18.6.36.1
Row definition of terminal emulation to ATM network IWF connections
Status: current Access: not-accessible
OBJECT-TYPE    
  Aal2TrunkConfigEntry  

aal2TrunkConfigIf 3.1.1751.2.18.6.36.1.1
Interface Id of the Atm Side of the Aal2 Trunk.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

aal2TrunkConfigVpi 3.1.1751.2.18.6.36.1.2
VPI value for Atm side , the atm side, of a atm trunk connection. Valid range is a number between 0 and 4095.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..4095  

aal2TrunkConfigVci 3.1.1751.2.18.6.36.1.3
VCI value for the atm side, of a variable bit rate-atm PVC VCC connection. Valid range is a number between 0 and 65535.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..65535  

aal2TrunkConfigServiceType 3.1.1751.2.18.6.36.1.4
Service/Queue types supported for Aal2 Trunk connections.When using Vbr/Ubr type service type oversubscription will have to be taken into account for which nature of traffic going over the Trunk should be known before hand
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER cbr-1(1), cbr-2(2), cbr-3(3), cbr-4(4), ubr(5), vbr-nrt2(6), vbr-nrt1(7), vbr-rt2(8), vbr-rt1(9), vbr-express(10)  

aal2TrunkConfigPeakCellRateIgr 3.1.1751.2.18.6.36.1.5
peak cell rate - atm side inp, in cell per second
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

aal2TrunkConfigSusCellRateIgr 3.1.1751.2.18.6.36.1.6
sustained rate - atm side inp, in cell per second
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

aal2TrunkConfigMaxBurstSizeIgr 3.1.1751.2.18.6.36.1.7
maximum burst size - atm side inp, in cells
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

aal2TrunkConfigPeakCellRateEgr 3.1.1751.2.18.6.36.1.8
peak rate - atm side output, in cell per second.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

aal2TrunkConfigSusCellRateEgr 3.1.1751.2.18.6.36.1.9
sustained rate - atm side output,in cell per second.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

aal2TrunkConfigMaxBurstSizeEgr 3.1.1751.2.18.6.36.1.10
maximum burst size - atm side output, in cells.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

aal2TrunkConfigFlow 3.1.1751.2.18.6.36.1.11
Flow type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER duplex(1)  

aal2TrunkConfigRowStatus 3.1.1751.2.18.6.36.1.12
row status
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

aal2TrunkConfigConnectionStatus 3.1.1751.2.18.6.36.1.13
Indicates the current connections status. Active: All interfaces through which the connection is going are in service. Inactive: One of the end interfaces of the connection is not in service. The rest of the states apply to connections going through resource interfaces like DSP2 and FEC. These interfaces are dynamically allocated . InactiveA2B-B2A: Both the A2B and B2A resource interfaces are not in service. InactiveA2B: The A2B resource interface is not in service. InactiveB2A: The B2A resource interface is not in service. If an end interface and the resource interfaces are out of service, the status will be inactive because the end interfaces take priority.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER active(1), inactive(2), inactiveA2B-B2A(3), inactiveA2B(4), inactiveB2A(5)  

aal2TrunkConfigViB 3.1.1751.2.18.6.36.1.14
VI to associate the Egress part of the A2B connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1024  

aal2TrunkConfigCnfrmTypeB2A 3.1.1751.2.18.6.36.1.15
The following is the description of this field This will be used in conjunction with the service type field to get the correct traffic behaviour. In the conformances the the 0 or 0plus1 refers to the clp bit in the cells. If 0plus1 is the bucket reference then the clp bit is ignored. If 0 is specified for the bucket then check only clp=0 cells. 1: Best Effort will try to send all cellsin a best effort way. This will follow the Aqueman Algorithm 2: one-bucket-notag-0plus1 will use 1 bucket i.e is the PCR(0+1) bucket and drop all cells in excess. 3: two-bucket-notag-0plus1-0plus1 uses 2 buckets. The 2 buckets are pcr(0+1) and scr(0+1). All cells conforming to both buckets will be passed through. The rest will be dropped. 4: two-bucket-notag-0plus1-0 uses 2 buckets. The 2 buckets are pcr(0+1) and scr(0) or pcr(0). Cells which conform to both buckets are passed through. The rest are dropped. 5: two-bucket-tag-0plus1-0 uses 2 buckets. The 2 buckets are pcr(0+1) and scr(0) or pcr(0). Cells which do not conform to the first bucket are dropped. Cells which do not conform to the 2nd bucket are tagged. 6: best-effort-tag. Tag all cells and then do a best effort.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER best-effort(1), one-bucket-notag-0plus1(2), two-bucket-notag-0plus1-0plus1(3), two-bucket-notag-0plus1-0(4), two-bucket-tag-0plus1-0(5), best-effort-tag(6)  

aal2TrunkConfigVUNIB 3.1.1751.2.18.6.36.1.16
VUNI to associate the Egress part of the A2B connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

aal2TrunkAvailBwIgr 3.1.1751.2.18.6.36.1.17
The Avail Bandwidth for that interface in cells per sec.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

aal2TrunkAvailBwEgr 3.1.1751.2.18.6.36.1.18
The Avail Bandwidth for that interface in cells per sec.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

aal2TrunkGR303 3.1.1751.2.18.6.36.1.19
This flag is used to check if a GR303 Feature is enabled for the trunk.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

aal2TrunkConfigOamStatus 3.1.1751.2.18.6.36.1.20
Indicates the OAM monitoring status of side A. The 2 possible states are: Unsupp: No monitoring enabled. End-Pt: Atm side is only an end point, therefore it will respond to AIS/RDI. End-Seg-Pt: A side is both an end point and a segment point.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unsupp(1), end-Pt(2), end-Seg-Pt(3)  

aal2TrunkConnFailureCauseB 3.1.1751.2.18.6.36.1.21
connection status reason code
Status: current Access: read-only
OBJECT-TYPE    
  AtmConnFailureCause  

aal2TrunkCuTimer 3.1.1751.2.18.6.36.1.22
CuTimer represents 'combined use timer', is set to zero such that every ATM cell transmitted contains one, and only one, AAL2 packet, and the first octet of the AAL2 packet header follows immediately after the Start Field in the ATM cell payload. If the AAL2 packet payload is less than 44 octets, the remainder of the ATM cell payload following the end of the AAL2 packet shall be filled with zeros as padding. Each increment of CuTimer means 5ms more to wait. And cuTimer default value 4 means to wait 20ms before the ATM cell is sent out.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..8  

gr303Aal2PvcVccTable 3.1.1751.2.18.6.37
Table of Gr303 to AAL2 Cid monitor VCCs
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gr303Aal2PvcVccEntry

gr303Aal2PvcVccEntry 3.1.1751.2.18.6.37.1
Row definition of circuit emulation to atm connections.
Status: current Access: not-accessible
OBJECT-TYPE    
  Gr303Aal2PvcVccEntry  

gr303Aal2PvcVccGr303IgId 3.1.1751.2.18.6.37.1.1
GR303 interface group id on the GR303 side of the connection
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..84  

gr303Aal2PvcVccGr303CallRef 3.1.1751.2.18.6.37.1.2
The call reference value to be used in the signaling packets on the GR303 interface for the connection on the AAL2CID corresponding to this connection
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..2048  

gr303Aal2PvcVccIfB 3.1.1751.2.18.6.37.1.3
Interface index for side B, the atm side, of a circuit emulation-atm PVC VCC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

gr303Aal2PvcVccVpiB 3.1.1751.2.18.6.37.1.4
VPI value for side B, the atm side, of a circuit emulation-atm PVC VCC connection. Valid range is a number between 0 and 4095.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..4095  

gr303Aal2PvcVccVciB 3.1.1751.2.18.6.37.1.5
VCI value for side B, the atm side, of a circuit emulation-atm PVC VCC connection. Valid range is a number between 0 and 65535.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..65535  

gr303Aal2PvcVccAal2Cid 3.1.1751.2.18.6.37.1.6
Aal2 Cid Used to pack ce chan in an Atm Trunk. This value will be unique per Atm Trunk. This field will be applicable when Aal type is chosen to be Standard Aal2.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..255  

gr303Aal2PvcVccRowStatus 3.1.1751.2.18.6.37.1.7
row status
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

gr303Aal2PvcVccVoiceEncodingProfile 3.1.1751.2.18.6.37.1.8
Profile for use by voice/voiceband data. Profile-3 and Profile-7 are ITU-T predefined profiles which specify the voice compression and silence removal algorithms. If custom profile is chosen all DSP specific parameters have to be specified by the user. If default profile is chosen all parameters on the AAL2 trunk, containing this CID, will be used.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER itut-profile-1(1), itut-profile-3(3), af-profile-6(6), itut-profile-7(7), af-profile-7(8), af-profile-8(9), af-profile-9(10), af-profile-10(11), af-profile-12(12), custom(256), default(257)  

gr303Aal2PvcVccVoiceCompression 3.1.1751.2.18.6.37.1.9
Voice Compression Algorithm
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), g726-16k(2), g726-24k(3), g726-32k(4), g726-40k(5), g729a-8k(6)  

gr303Aal2PvcVccSilenceDetection 3.1.1751.2.18.6.37.1.10
silence detection off/on
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

gr303Aal2PvcVccEchoCancellation 3.1.1751.2.18.6.37.1.11
Echo Cancellation Algorithm
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), g165-nearEnd(2), g168(3)  

gr303Aal2PvcVccCngToneDetection 3.1.1751.2.18.6.37.1.12
Calling Tone Detection Algorithm
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), bypass(2)  

gr303Aal2PvcVccCodingTranslation 3.1.1751.2.18.6.37.1.13
Coding rule translation type.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), muLaw2muLaw(2), aLaw2aLaw(3), muLaw2aLaw(4), aLaw2muLaw(5)  

gr303Aal2PvcVccConnectionStatus 3.1.1751.2.18.6.37.1.14
Indicates the current connections status. Active: All interfaces through which the connection is going are in service. Inactive: One of the end interfaces of the connection is not in service. The rest of the states apply to connections going through resource interfaces like DSP2 and FEC. These interfaces are dynamically allocated. If an end interface and the resource interfaces are out of service, the status will be inactive because the end interfaces take priority.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER active(1), inactive(2)  

gr303Aal2PvcVccAltLineType 3.1.1751.2.18.6.37.1.15
Analog Line Termination Line Type on the subscriber side. The ABCD bit codes for diffterent signal types depend on the analog line type. The analog type can be overwritten by an EOC message from the IDT
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER alt-LoopReverseBattery(1), alt-groundStart(9), alt-loopStart(13), alt-winkStart(29)  

atmAtmSpvcVpcTable 3.1.1751.2.18.6.38
Table of SPVC ATM virtual path connections.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmAtmSpvcVpcEntry

atmAtmSpvcVpcEntry 3.1.1751.2.18.6.38.1
Row definition of ATM SPVC VPC connections.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmAtmSpvcVpcEntry  

atmAtmSpvcVpcVpiA 3.1.1751.2.18.6.38.1.1
VPI value for side A of an ATM SPVC VPC connection. Valid range is a number between 0 and 4095.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..4095  

atmAtmSpvcVpcRemoteAtmPortAddr 3.1.1751.2.18.6.38.1.2
Remote ATM port NSAP address, not meaningful if passive type of connection.
Status: current Access: not-accessible
OBJECT-TYPE    
  OCTET STRING Size(1..20)  

atmAtmSpvcVpcIfB 3.1.1751.2.18.6.38.1.3
Interface index for side B of an ATM SPVC VPC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the path number.
Status: current Access: read-only
OBJECT-TYPE    
  IntfIndex  

atmAtmSpvcVpcVpiB 3.1.1751.2.18.6.38.1.4
VPI value for side B of an ATM SPVC VPC connection. Valid range is a number between 0 and 4095.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..4095  

atmAtmSpvcVpcServiceTypeA2B 3.1.1751.2.18.6.38.1.5
Service type, ATM port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ubr(1), vbr-nrt2(2), vbr-nrt1(3), vbr-rt2(4), vbr-rt1(5), vbr-express(6), cbr4(7), cbr3(8), cbr2(9)  

atmAtmSpvcVpcSarTypeA2B 3.1.1751.2.18.6.38.1.6
SAR type used in ATM adaption, ATM port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER aal5(1), aal3-4(2), aal2(3), aal1(4), null(5)  

atmAtmSpvcVpcPeakCellRateA2B 3.1.1751.2.18.6.38.1.7
Peak cell rate - side A, ATM port, in cells per second.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVpcSusCellRateA2B 3.1.1751.2.18.6.38.1.8
Sustained cell rate - side A, ATM port, in cells per second.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVpcMaxBurstSizeA2B 3.1.1751.2.18.6.38.1.9
Maximum burst size - side A, ATM port, in cells per second.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVpcFrwdErrCorrectionA2B 3.1.1751.2.18.6.38.1.10
Forward error correction scheme, ATM port side.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), eighthRate(2), quarterRate(3), halfRate(4), autoHiQ(5), auto(6), autoLoQ(7)  

atmAtmSpvcVpcServiceTypeB2A 3.1.1751.2.18.6.38.1.11
Service type, ATM trunk side.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ubr(1), vbr-nrt2(2), vbr-nrt1(3), vbr-rt2(4), vbr-rt1(5), vbr-express(6), cbr4(7), cbr3(8), cbr2(9)  

atmAtmSpvcVpcSarTypeB2A 3.1.1751.2.18.6.38.1.12
SAR type used in ATM adaption, ATM trunk side.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER aal5(1), aal3-4(2), aal2(3), aal1(4), null(5)  

atmAtmSpvcVpcPeakCellRateB2A 3.1.1751.2.18.6.38.1.13
Peak cell rate - side B, ATM trunk, in cells per second.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVpcSusCellRateB2A 3.1.1751.2.18.6.38.1.14
Sustained cell rate - side B, ATM trunk, in cells per second.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVpcMaxBurstSizeB2A 3.1.1751.2.18.6.38.1.15
Maximum burst size - side A, ATM trunk, in cells per second.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVpcFrwdErrCorrectionB2A 3.1.1751.2.18.6.38.1.16
Forward error correction scheme, ATM trunk side.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), eighthRate(2), quarterRate(3), halfRate(4), autoHiQ(5), auto(6), autoLoQ(7)  

atmAtmSpvcVpcFlow 3.1.1751.2.18.6.38.1.17
Type of flow, pointToMultipointA2B is for future support.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER duplex(1), simplexA2B(2), pointToMultipointA2B(3), simplexB2A(4), pointToMultipointB2A(5)  

atmAtmSpvcVpcType 3.1.1751.2.18.6.38.1.18
Type of connection.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER nonsecured(1), secured(2)  

atmAtmSpvcVpcConnType 3.1.1751.2.18.6.38.1.19
The type of connection: activeSvc - attempt calls, whenever not established. passiveSvc - accept calls.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER activeSvc(1), passiveSvc(2)  

atmAtmSpvcVpcLeafReference 3.1.1751.2.18.6.38.1.20
An arbitrary integer which serves to distinguish the mulitple leaves attached to a root of a point-to-multipoint SPVC. If point-to-point SPVC, the value should be 1.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

atmAtmSpvcVpcOperStatus 3.1.1751.2.18.6.38.1.21
The operation status of the connection: other - none of the types specified below. establishmentInProgress - connection is not operational, but call attempts are ongoing. connected - connection is currently operational. retriesExhausted - retry limit has been reached and call attempts have ceased. noAddressSupplied - no remote address has been configured, so no call attempts are initiated. lowerLayerDown - SPVC handler is not operational.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER other(1), establishmentInProgress(2), connected(3), retriesExhausted(4), noAddressSupplied(5), lowerLayerDown(6), waitingForCall(7), waitingForRetryTimer(8)  

atmAtmSpvcVpcRowStatus 3.1.1751.2.18.6.38.1.22
Used to create and delete a soft PVC. When this object is set to 'active', an attempt is made to set up the soft PVC. When this object has the value 'active' and is set to another value, any setup or connection in-progress is released.
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

atmAtmSpvcVpcRemoteSelectType 3.1.1751.2.18.6.38.1.23
Indicates whether the remote VPI values are to be used at the destination. If 'any' is used, the destination switch will choose the VPI values. In such a case, once the SPVC is connected, the value of this object will change to 'required', such that the same VPI values will continue to be used even if the connection is torn down and re-established. If the value 'required' is specified, the values: atmAtmSpvcVpcRemoteVpi and must be supplied and are used at the destination.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER required(1), any(2)  

atmAtmSpvcVpcRemoteVpi 3.1.1751.2.18.6.38.1.24
VPI value to be used at the destination of an ATM SPVC VPC connection. Valid range is a number between 0 and 4095. If atmAtmSpvcVpcRemoteSelectType is configured as 'any', then this value is not relevant.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

atmAtmSpvcVpcRetryInterval 3.1.1751.2.18.6.38.1.25
The time to wait before attempting to establish the SVC after a previous failed call attempt. A value of 0 indicates retries will be attempted immediately.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..3600  

atmAtmSpvcVpcRetryLimit 3.1.1751.2.18.6.38.1.26
A maximum limit on how many retries should be attempted. A value of 0 indicates no limit.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

atmAtmSpvcVpcRestart 3.1.1751.2.18.6.38.1.27
The active SVC is released, if necessary, and a new setup procedure is begun if 'restart', otherwise, noop.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER restart(1), noop(2)  

atmAtmSpvcVpcRetryFailure 3.1.1751.2.18.6.38.1.28
Indicates how many attempts to establish the connection have failed. It it reset whenever a connection is successfully established or the SVC is restarted.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVpcReleaseCause 3.1.1751.2.18.6.38.1.29
CAUSE field value of the last RELEASE message received for this SVC.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..127  

atmAtmSpvcVpcReleaseDiag 3.1.1751.2.18.6.38.1.30
DIAGNOSTICS field value of the last RELEASE message received for this SVC.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..8)  

atmAtmSpvcVpcRelease 3.1.1751.2.18.6.38.1.31
Release the connnection established on the endpoint and if the endpoint is Active, do not retry.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER release(1), noop(2)  

atmAtmSpvcVpcStatsInCellCountHiA 3.1.1751.2.18.6.38.1.32
Valid Cells received on A - (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVpcStatsInCellCountLoA 3.1.1751.2.18.6.38.1.33
Valid Cells received on A - (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVpcStatsOutCellCountHiA 3.1.1751.2.18.6.38.1.34
Valid cells transmitted on A -(High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVpcStatsOutCellCountLoA 3.1.1751.2.18.6.38.1.35
Valid cells transmitted on A -(Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVpcStatsInCellCountHiB 3.1.1751.2.18.6.38.1.36
Valid Cells received on B - (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVpcStatsInCellCountLoB 3.1.1751.2.18.6.38.1.37
Valid Cells received on B - (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVpcStatsOutCellCountHiB 3.1.1751.2.18.6.38.1.38
Valid cells transmitted on B -(High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVpcStatsOutCellCountLoB 3.1.1751.2.18.6.38.1.39
Valid cells transmitted on B -(Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVpcStatsTimer 3.1.1751.2.18.6.38.1.40
Number of seconds stats have been collecting
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVpcStatsFrwdErrCrrctnRateA2B 3.1.1751.2.18.6.38.1.41
Displays the Forward error correction rate being used by the FEC module in the A2B direction. This field is dynamic when Auto rates are selected. In other cases, it will display the rate set by the user.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), eighthRate(2), quarterRate(3), halfRate(4)  

atmAtmSpvcVpcStatsFrwdErrCrrctnRateB2A 3.1.1751.2.18.6.38.1.42
Displays the Forward error correction rate being used by the FEC module in the B2A direction. This field is dynamic when Auto rates are selected. In other cases, it will display the rate set by the user.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), eighthRate(2), quarterRate(3), halfRate(4)  

atmAtmSpvcVpcStatsInOdometerCellCountHiA 3.1.1751.2.18.6.38.1.43
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVpcStatsInOdometerCellCountLoA 3.1.1751.2.18.6.38.1.44
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVpcStatsOutOdometerCellCountHiA 3.1.1751.2.18.6.38.1.45
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVpcStatsOutOdometerCellCountLoA 3.1.1751.2.18.6.38.1.46
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVpcStatsInOdometerCellCountHiB 3.1.1751.2.18.6.38.1.47
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVpcStatsInOdometerCellCountLoB 3.1.1751.2.18.6.38.1.48
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVpcStatsOutOdometerCellCountHiB 3.1.1751.2.18.6.38.1.49
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVpcStatsOutOdometerCellCountLoB 3.1.1751.2.18.6.38.1.50
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVpcStatsOdometerTimer 3.1.1751.2.18.6.38.1.51
Number of seconds since odometer was reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVpcStatsOdometerReset 3.1.1751.2.18.6.38.1.52
Odometer reset button.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reset(1)  

atmAtmSpvcVpcViA 3.1.1751.2.18.6.38.1.53
VI to associate the Egress part of the B2A connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1024  

atmAtmSpvcVpcViB 3.1.1751.2.18.6.38.1.54
VI to associate the Egress part of the A2B connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1024  

atmAtmSpvcVpcStatsCellsDroppedA 3.1.1751.2.18.6.38.1.55
Cells Dropped on the Incoming side of A
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVpcStatsCellsTaggedA 3.1.1751.2.18.6.38.1.56
Cells Tagged on the Incoming side of A
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVpcStatsCellsDroppedB 3.1.1751.2.18.6.38.1.57
Cells Dropped on the Incoming side of B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVpcStatsCellsTaggedB 3.1.1751.2.18.6.38.1.58
Cells Tagged on the Incoming side of B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAtmSpvcVpcVUNIA 3.1.1751.2.18.6.38.1.59
VUNI to associate the Egress part of the B2A connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

atmAtmSpvcVpcVUNIB 3.1.1751.2.18.6.38.1.60
VUNI to associate the Egress part of the A2B connection .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

atmAtmSpvcVpcTrafficShapingA2B 3.1.1751.2.18.6.38.1.61
Traffic Shaping Support in the A2B direction.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

atmAtmSpvcVpcTrafficShapingB2A 3.1.1751.2.18.6.38.1.62
Traffic Shaping Support in the B2A direction.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

atmAtmSpvcVpcPriority 3.1.1751.2.18.6.38.1.63
Priority of SPVC - priority-1 being highest priority .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER priority-1(1), priority-2(2), priority-3(3), priority-4(4)  

intfAtmPvcConnDisplayTable 3.1.1751.2.18.6.39
List of Pvc Connections on an Interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IntfAtmConnDisplayEntry

intfAtmPvcConnDisplayEntry 3.1.1751.2.18.6.39.1
Gives list of pvc going towards the backplane on a particluar interface
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfAtmConnDisplayEntry  

intfAtmPvcConnDisplaySlot 3.1.1751.2.18.6.39.1.1
Slot of the particular interface
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

intfAtmPvcConnDisplayPort 3.1.1751.2.18.6.39.1.2
Port of the particular interface
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

intfAtmPvcConnDisplayChannel 3.1.1751.2.18.6.39.1.3
Channel of the particular interface
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

intfAtmPvcConnDisplayVpi 3.1.1751.2.18.6.39.1.4
VPI value for connection on Intf Valid range is a number between 0 and 4095.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..4095  

intfAtmPvcConnDisplayVci 3.1.1751.2.18.6.39.1.5
VCI value for connection on Intf Valid range is a number between 0 and 65535.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..65535  

intfAtmPvcConnDisplayFlowType 3.1.1751.2.18.6.39.1.6
Flow type:Indicates Flow Towards the Back Plane cnctnValid: Traffic flow towards BP is enabled. cnctnNull: Traffic flow towards BP is disabled. cnctnPtmpValid: Traffic flow towards BP is enabled and it is point to multipoint connection. cnctnPtmpNull: Traffic flow towards BP is disabled and it is point to multipoint connection.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER cnctnValid(1), cnctnNull(2), cnctnPtmpValid(3), cnctnPtmpNull(4)  

ds3PortStatsTable 3.1.1751.2.18.10.1
Table of statisics for a DS3 port
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ds3PortStatsEntry

ds3PortStatsEntry 3.1.1751.2.18.10.1.1
Row definition for the DS3 port statistics table
Status: current Access: not-accessible
OBJECT-TYPE    
  Ds3PortStatsEntry  

ds3PortStatsId 3.1.1751.2.18.10.1.1.1
Port ID - Slot/Port (SSPP)
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

ds3PortStatsTimer 3.1.1751.2.18.10.1.1.2
The number of seconds that have elapsed since the beginning of the current error-measurement period.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ds3PortStatsCurrentSEFSs 3.1.1751.2.18.10.1.1.3
severely errored framing seconds
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ds3PortStatsCurrentLCVs 3.1.1751.2.18.10.1.1.4
Line coding violations encountered
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ds3PortStatsCurrentLESs 3.1.1751.2.18.10.1.1.5
Line errored seconds
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ds1PortStatsTable 3.1.1751.2.18.10.2
Table of statisics for a DS1 port
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ds1PortStatsEntry

ds1PortStatsEntry 3.1.1751.2.18.10.2.1
Row definition for the DS1 port statistics table
Status: current Access: not-accessible
OBJECT-TYPE    
  Ds1PortStatsEntry  

ds1PortStatsId 3.1.1751.2.18.10.2.1.1
Port ID - Slot/Port (SSPP)
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

ds1PortStatsTimer 3.1.1751.2.18.10.2.1.2
The number of seconds that have elapsed since the beginning of the current error-measurement period.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ds1PortStatsCurrentESs 3.1.1751.2.18.10.2.1.3
The number of Errored Seconds, encountered by a DS1 interface.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ds1PortStatsCurrentSESs 3.1.1751.2.18.10.2.1.4
The number of Severely Errored Seconds encoun- tered by a DS1 interface.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ds1PortStatsCurrentLCVs 3.1.1751.2.18.10.2.1.5
The number of Line Code Violations (LCVs) en- countered by a DS1 interface.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

oc3PortStatsTable 3.1.1751.2.18.10.3
Table of statisics for a OC3 port
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Oc3PortStatsEntry

oc3PortStatsEntry 3.1.1751.2.18.10.3.1
Row definition for the OC3 port statistics table
Status: current Access: not-accessible
OBJECT-TYPE    
  Oc3PortStatsEntry  

oc3PortStatsId 3.1.1751.2.18.10.3.1.1
Port ID - Slot/Port (SSPP)
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

oc3PortStatsSectionBip8Errs 3.1.1751.2.18.10.3.1.2
section sublayer BIP8 errors.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

oc3PortStatsLineBip8Errs 3.1.1751.2.18.10.3.1.3
line sublayer BIP8 errors.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

oc3PortStatsPathBip8Errs 3.1.1751.2.18.10.3.1.4
path sublayer BIP8 errors.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

oc3PortStatsLineFebeCount 3.1.1751.2.18.10.3.1.5
line sublayer FEBE count.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

oc3PortStatsPathFebeCount 3.1.1751.2.18.10.3.1.6
path sublayer FEBE count.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

oc3PortStatsTimer 3.1.1751.2.18.10.3.1.7
The number of seconds that have elapsed since the beginning of the current error-measurement period.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

msPortStatsTable 3.1.1751.2.18.10.4
Table of statisics for a MS port
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MsPortStatsEntry

msPortStatsEntry 3.1.1751.2.18.10.4.1
Row definition for the MS port statistics table
Status: current Access: not-accessible
OBJECT-TYPE    
  MsPortStatsEntry  

msPortStatsId 3.1.1751.2.18.10.4.1.1
Port ID - Slot/Port (SSPP)
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

msPortStatsFrameErrors 3.1.1751.2.18.10.4.1.4
P-bit severely errored seconds
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

msPortStatsOutOfFrameSeconds 3.1.1751.2.18.10.4.1.5
severely errored framing seconds
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

msPortStatsTimer 3.1.1751.2.18.10.4.1.6
The number of seconds that have elapsed since the beginning of the current error-measurement period.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

e3PortStatsTable 3.1.1751.2.18.10.5
Table of statisics for a E3 port
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    E3PortStatsEntry

e3PortStatsEntry 3.1.1751.2.18.10.5.1
Row definition for the E3 port statistics table
Status: current Access: not-accessible
OBJECT-TYPE    
  E3PortStatsEntry  

e3PortStatsId 3.1.1751.2.18.10.5.1.1
Port ID - Slot/Port (SSPP)
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

e3PortStatsTimer 3.1.1751.2.18.10.5.1.2
The number of seconds that have elapsed since the beginning of the current error-measurement period.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

e3PortStatsCurrentSEFSs 3.1.1751.2.18.10.5.1.3
severely errored framing seconds
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

e3PortStatsCurrentLCVs 3.1.1751.2.18.10.5.1.4
Line coding violations encountered
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

e3PortStatsCurrentLESs 3.1.1751.2.18.10.5.1.5
Line errored seconds
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

e1PortStatsTable 3.1.1751.2.18.10.6
Table of statisics for a E1 port
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    E1PortStatsEntry

e1PortStatsEntry 3.1.1751.2.18.10.6.1
Row definition for the E1 port statistics table
Status: current Access: not-accessible
OBJECT-TYPE    
  E1PortStatsEntry  

e1PortStatsId 3.1.1751.2.18.10.6.1.1
Port ID - Slot/Port (SSPP)
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

e1PortStatsTimer 3.1.1751.2.18.10.6.1.2
The number of seconds that have elapsed since the beginning of the current error-measurement period.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

e1PortStatsCurrentESs 3.1.1751.2.18.10.6.1.3
The number of Errored Seconds, encountered by a E1 interface.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

e1PortStatsCurrentSESs 3.1.1751.2.18.10.6.1.4
The number of Severely Errored Seconds encoun- tered by a E1 interface.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

e1PortStatsCurrentLCVs 3.1.1751.2.18.10.6.1.5
The number of Line Code Violations (LCVs) en- countered by a E1 interface.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ethernetPortStatsTable 3.1.1751.2.18.10.7
Statisics for a collection of ethernet-like interfaces attached to a particular system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EthernetPortStatsEntry

ethernetPortStatsEntry 3.1.1751.2.18.10.7.1
Statistics for a particular interface to an ethernet-like medium.
Status: current Access: not-accessible
OBJECT-TYPE    
  EthernetPortStatsEntry  

ethernetPortStatsId 3.1.1751.2.18.10.7.1.1
An index value that uniquely identifies an interface to an ethernet-like medium. The interface identified by a particular value of this index is the same interface as identified by the same value of ethernetPortId.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

ethernetPortStatsTimer 3.1.1751.2.18.10.7.1.2
Time, in seconds, since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ethernetPortStatsAlignmentErrors 3.1.1751.2.18.10.7.1.3
A count of frames received on a particular interface that are not an integral number of octets in length and do not pass the FCS check. The count represented by an instance of this object is incremented when the alignmentError status is returned by the MAC service to the LLC (or other MAC user). Received frames for which multiple error conditions obtain are, according to the conventions of IEEE 802.3 Layer Management, counted exclusively according to the error status presented to the LLC.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ethernetPortStatsFCSErrors 3.1.1751.2.18.10.7.1.4
A count of frames received on a particular interface that are an integral number of octets in length but do not pass the FCS check. The count represented by an instance of this object is incremented when the frameCheckError status is returned by the MAC service to the LLC (or other MAC user). Received frames for which multiple error conditions obtain are, according to the conventions of IEEE 802.3 Layer Management, counted exclusively according to the error status presented to the LLC.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ethernetPortStatsSingleCollisionFrames 3.1.1751.2.18.10.7.1.5
A count of successfully transmitted frames on a particular interface for which trnasmission is inhibited by exactly one collision. A frame that is counted by an instance of this object is also counted by the corresponding instance of either the ifOutUcastPkts, IfOutMulticastPkts, or ifOutBroadcastPkts, and is not counted by the corresponding instance of the ethernetPortStatsMulitipleCollisionFrames object.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ethernetPortStatsMultipleCollisionFrames 3.1.1751.2.18.10.7.1.6
A count of successfully transmitted frames on a particular interface for which trnasmission is inhibited by more than one collision. A frame that is counted by an instance of this object is also counted by the corresponding instance of either the ifOutUcastPkts, IfOutMulticastPkts, or ifOutBroadcastPkts, and is not counted by the corresponding instance of the ethernetPortStatsSingleCollisionFrames object.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ethernetPortStatsSQETestErrors 3.1.1751.2.18.10.7.1.7
A count of times that the SQE TEST ERROR message is generated by the PLS sublayer for a particular interface. The SQE TEST ERROR message is defined in section 7.2.2.2.4 of ANSI/IEEE 802.3-1985 and its generation is described in section 7.2.4.6 of the same document.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ethernetPortStatsDeferredTransmissions 3.1.1751.2.18.10.7.1.8
A count of frames for which the first transmission attempt on a particluar interface is delayed because the medium is busy. the count represented by an instance of this object does not include frames involved in collisions.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ethernetPortStatsLateCollisions 3.1.1751.2.18.10.7.1.9
The number of times that a collision is detected on a particular interface later than 512 bit-times into the transmission of a packet. Five hundred and twelve bit-times corresponds to 51.2 microseconds on a 10 Mbit/s system. A (late) collision included in a count represented by an instance of this object is also considered as a (generic) collision for purposes of other collision-related statistics.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ethernetPortStatsExcessiveCollisions 3.1.1751.2.18.10.7.1.10
A count of frames for which transmission on a particular interface fails due to excessive collisions.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ethernetPortStatsInternalMacTransmitErrors 3.1.1751.2.18.10.7.1.11
A count of frames for which transmission on a particular interface fails due to an internal MAC sublayer transmit error. A frame is only counted by an instance of this object if it is not counted by the corresponding instance of either the ethernetPortStatsLateCollisions object, the ethernetPortStatsExcessiveCollisions object, or the ethernetPortStatsCarrierSenseErrors object. The precise meaning of the count represented by an instance of this object is implementation- specific. In particular, an instance of this object may represent a count of transmission errors on a particular interface that are not otherwise counted.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ethernetPortStatsCarrierSenseErrors 3.1.1751.2.18.10.7.1.12
The number of times that the carrier sense condition was lost or never asserted when attempting to transmit a frame on a particular interface. The count represented by an instance of this object is incremented at most once per transmission attempt, even if the carrier sense condition fluctuates during a transmission attempt.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ethernetPortStatsFrameTooLongs 3.1.1751.2.18.10.7.1.13
A count of frames received on a particular interface that exceed the maximum permitted frame size. The count represented by an instance of this object is incremented when the frameTooLong status is returned by the MAC service to the LLC (or other MAC user). Received frames for which multiple error conditions obtain are, according to the conventions of IEEE 802.3 Layer Management, counted exclusively according to the error status presented to the LLC.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ethernetPortStatsInternalMacReceiveErrors 3.1.1751.2.18.10.7.1.14
A count of frames for which reception on a particular interface fails due to an internal MAC sublayer receive error. A frame is only counted by an instance of this object if it is not counted by the corresponding instance of either the ethernetPortStatsFrameTooLongs object, the ethernetPortStatsAlignmentErrors object, or the ethernetPortStatsFCSErrors object. The precise meaning of the count represented by an instance of this object is implementation- specific. In particular, an instance of this object may represent a count of receive errors on a particular interface that are not otherwise counted.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmIfStatsTable 3.1.1751.2.18.11.1
Table of statistics for an atmUni interface
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmIfStatsEntry

atmIfStatsEntry 3.1.1751.2.18.11.1.1
Row definition for the atmUni statistics table
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmIfStatsEntry  

atmIfStatsId 3.1.1751.2.18.11.1.1.1
Interface index (SSPPCCC) to the atmUni statistics table
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

atmIfStatsValidCellsInHi 3.1.1751.2.18.11.1.1.2
Number of valid cells received on the channel - High Word
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmIfStatsValidCellsInLo 3.1.1751.2.18.11.1.1.3
Number of valid cells received on the channel - low Word
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmIfStatsErroredCellsIn 3.1.1751.2.18.11.1.1.4
Number of errored cells received on the channel
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmIfStatsMismatchedCellsIn 3.1.1751.2.18.11.1.1.5
Number of Vpi/Vci translation errors on input cells.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmIfStatsNullCellsOutHi 3.1.1751.2.18.11.1.1.6
Number of null cells sent out on the channel - High Word
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmIfStatsNullCellsOutLo 3.1.1751.2.18.11.1.1.7
Number of null cells sent out on the channel - Low Word
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmIfStatsValidCellsOutHi 3.1.1751.2.18.11.1.1.8
Number of valid cells sent out on the channel - High Word
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmIfStatsValidCellsOutLo 3.1.1751.2.18.11.1.1.9
Number of valid cells sent out on the channel - Low Word
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmIfStatsTimer 3.1.1751.2.18.11.1.1.10
Time, in seconds, since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..899  

frUniStatsTable 3.1.1751.2.18.11.2
Table of statistics for a Frame Relay UNI Interface
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FrUniStatsEntry

frUniStatsEntry 3.1.1751.2.18.11.2.1
Row definition for the Frame Realy UNI statistics table
Status: current Access: not-accessible
OBJECT-TYPE    
  FrUniStatsEntry  

frUniStatsId 3.1.1751.2.18.11.2.1.1
Interface index (SSPPCCC) to the frame relay UNI statistics table
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

frUniStatsTimer 3.1.1751.2.18.11.2.1.9
Time, in seconds, since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..899  

frUniStatsCellsMismatched 3.1.1751.2.18.11.2.1.10
number of cells not matched to provisioned DLCIs.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frUniStatsErroredFrames 3.1.1751.2.18.11.2.1.11
number of errored frames.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frUniStatsCellsEncodedHi 3.1.1751.2.18.11.2.1.12
number of cells encoded - (High order portion).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frUniStatsCellsEncodedLo 3.1.1751.2.18.11.2.1.13
number of cells encoded - (Low order portion).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frUniStatsFramesEncodedHi 3.1.1751.2.18.11.2.1.14
number of frames encoded - (High order portion).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frUniStatsFramesEncodedLo 3.1.1751.2.18.11.2.1.15
number of frames encoded - (Low order portion).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frUniStatsCellsDecodedHi 3.1.1751.2.18.11.2.1.16
number of cells decoded - (High order portion).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frUniStatsCellsDecodedLo 3.1.1751.2.18.11.2.1.17
number of cells decoded - (Low order portion).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frUniStatsFramesDecodedHi 3.1.1751.2.18.11.2.1.18
number of frames decoded - (High order portion).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frUniStatsFramesDecodedLo 3.1.1751.2.18.11.2.1.19
number of frames decoded - (Low order portion).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frUniStatsAAL5Errors 3.1.1751.2.18.11.2.1.20
number of aal5 PDUs with invalid byte count or CRC-32.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmIfStatsTable 3.1.1751.2.18.11.3
Table of statistics for an cirEm interface
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CirEmIfStatsEntry

cirEmIfStatsEntry 3.1.1751.2.18.11.3.1
Row definition for the cirEm statistics table
Status: current Access: not-accessible
OBJECT-TYPE    
  CirEmIfStatsEntry  

cirEmIfStatsId 3.1.1751.2.18.11.3.1.1
Interface index (SSPPCCC) to the cirEm statistics table
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

cirEmIfStatsCellsEncodedHi 3.1.1751.2.18.11.3.1.2
Incoming cells from the outside media to the i/o port
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmIfStatsCellsEncodedLo 3.1.1751.2.18.11.3.1.3
Incoming cells from the outside media to the i/o port
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmIfStatsCellsDecodedHi 3.1.1751.2.18.11.3.1.4
Outgoing cells from the i/o port to the outside media
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmIfStatsCellsDecodedLo 3.1.1751.2.18.11.3.1.5
Outgoing cells from the i/o port to the outside media
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmIfStatsTimer 3.1.1751.2.18.11.3.1.6
Time, in seconds, since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..899  

vbrIfStatsTable 3.1.1751.2.18.11.4
Table of statistics for an vbr interface
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VbrIfStatsEntry

vbrIfStatsEntry 3.1.1751.2.18.11.4.1
Row definition for the vbr statistics table
Status: current Access: not-accessible
OBJECT-TYPE    
  VbrIfStatsEntry  

vbrIfStatsId 3.1.1751.2.18.11.4.1.1
Interface index (SSPPCCC) to the vbr statistics table
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

vbrIfStatsCellsEncodedHi 3.1.1751.2.18.11.4.1.2
Incoming cells from the outside media to the i/o port
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrIfStatsCellsEncodedLo 3.1.1751.2.18.11.4.1.3
Incoming cells from the outside media to the i/o port
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrIfStatsCellsDecodedHi 3.1.1751.2.18.11.4.1.4
Outgoing cells from the i/o port to the outside media
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrIfStatsCellsDecodedLo 3.1.1751.2.18.11.4.1.5
Outgoing cells from the i/o port to the outside media
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrIfStatsTimer 3.1.1751.2.18.11.4.1.6
Time, in seconds, since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..899  

frLmiStatsTable 3.1.1751.2.18.11.5
Table of statistics for a Frame Relay LMI Interface
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FrLmiStatsEntry

frLmiStatsEntry 3.1.1751.2.18.11.5.1
Row definition for the Frame Realy LMI statistics table
Status: current Access: not-accessible
OBJECT-TYPE    
  FrLmiStatsEntry  

frLmiStatsId 3.1.1751.2.18.11.5.1.1
Interface index (SSPPCCC) to the frame relay LMI statistics table
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

frLmiStatsEnqRx 3.1.1751.2.18.11.5.1.2
number of STATUS ENQ messages received
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frLmiStatsEnqTx 3.1.1751.2.18.11.5.1.3
number of STATUS ENQ messages transmitted
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frLmiStatsStatusRx 3.1.1751.2.18.11.5.1.4
number of STATUS messages received
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frLmiStatsStatusTx 3.1.1751.2.18.11.5.1.5
number of STATUS messages transmitted
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frLmiStatsAsyncRx 3.1.1751.2.18.11.5.1.6
number of ASYNC STATUS messages received
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frLmiStatsAsyncTx 3.1.1751.2.18.11.5.1.7
number of ASYNC STATUS messages transmitted
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frLmiStatsPktDisc 3.1.1751.2.18.11.5.1.8
The number of lmi messages discarded due to invalid length, receive sequence numbers, or other error.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frLmiStatsT391Exp 3.1.1751.2.18.11.5.1.9
Link integrity verification polling timer expiry
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..899  

frLmiStatsT392Exp 3.1.1751.2.18.11.5.1.10
Polling verification timer expiry
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..899  

frLmiStatsLinkReset 3.1.1751.2.18.11.5.1.11
Number of times interface operational status was in service after system startup.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..899  

frLmiStatsTimer 3.1.1751.2.18.11.5.1.12
Time since last reset for statistics - in seconds
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..899  

bridgeStatsTable 3.1.1751.2.18.11.6
Table of statistics for a bridge interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    BridgeStatsEntry

bridgeStatsEntry 3.1.1751.2.18.11.6.1
Row definition for the bridge interface statistics table
Status: current Access: not-accessible
OBJECT-TYPE    
  BridgeStatsEntry  

bridgeStatsId 3.1.1751.2.18.11.6.1.1
Interface index (SSPPCCC) to the bridge
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

bridgeStatsTimer 3.1.1751.2.18.11.6.1.2
Time, in seconds, since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeStatsBasePortDelayExceededDiscardsHi 3.1.1751.2.18.11.6.1.8
The number of frames discarded by this port due to excessive transit delay through the bridge. It is incremented by both transparent and source route bridges. High-order 32 bits.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeStatsBasePortDelayExceededDiscardsLo 3.1.1751.2.18.11.6.1.9
The number of frames discarded by this port due to excessive transit delay through the bridge. It is incremented by both transparent and source route bridges. Low-order 32 bits.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeStatsBasePortMtuExceededDiscardsHi 3.1.1751.2.18.11.6.1.10
The number of frames discarded by this port due to an excessive size. It is incremented by both transparent and source route bridges. High-order 32 bits.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeStatsBasePortMtuExceededDiscardsLo 3.1.1751.2.18.11.6.1.11
The number of frames discarded by this port due to an excessive size. It is incremented by both transparent and source route bridges. Low-order 32 bits.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeStatsTpPortInFramesHi 3.1.1751.2.18.11.6.1.12
The number of frames that have been received by this port from its segment. Note that a frame received on the interface corresponding to this port is only counted by this object if and only if it is for a protocol being processed by the local bridging function, including bridge management frames. High-order 32 bits.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeStatsTpPortInFramesLo 3.1.1751.2.18.11.6.1.13
The number of frames that have been received by this port from its segment. Note that a frame received on the interface corresponding to this port is only counted by this object if and only if it is for a protocol being processed by the local bridging function, including bridge management frames. Low-order 32 bits.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeStatsTpPortOutFramesHi 3.1.1751.2.18.11.6.1.14
The number of frames that have been transmitted by this port to its segment. Note that a frame transmitted on the interface corresponding to this port is only counted by this object if and only if it is for a protocol being processed by the local bridging function, including bridge management frames. High-order 32 bits.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeStatsTpPortOutFramesLo 3.1.1751.2.18.11.6.1.15
The number of frames that have been transmitted by this port to its segment. Note that a frame transmitted on the interface corresponding to this port is only counted by this object if and only if it is for a protocol being processed by the local bridging function, including bridge management frames. Low-order 32 bits.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeStatsTpPortInDiscardsHi 3.1.1751.2.18.11.6.1.16
Count of valid frames received which were discarded (i.e., filtered) by the Forwarding Process. High-order 32 bits.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeStatsTpPortInDiscardsLo 3.1.1751.2.18.11.6.1.17
Count of valid frames received which were discarded (i.e., filtered) by the Forwarding Process. Low-order 32 bits.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

dbCirEmIfStatsTable 3.1.1751.2.18.11.7
Table of statistics for a dbCirEm interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DbCirEmIfStatsEntry

dbCirEmIfStatsEntry 3.1.1751.2.18.11.7.1
Row definition for the dbCirEm statistics table.
Status: current Access: not-accessible
OBJECT-TYPE    
  DbCirEmIfStatsEntry  

dbCirEmIfStatsId 3.1.1751.2.18.11.7.1.1
Interface index (SSPPCCC) to the dbCirEm statistics table.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

dbCirEmIfStatsCellsEncodedHi 3.1.1751.2.18.11.7.1.2
Incoming cells from the outside media to the i/o port.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

dbCirEmIfStatsCellsEncodedLo 3.1.1751.2.18.11.7.1.3
Incoming cells from the outside media to the i/o port.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

dbCirEmIfStatsCellsDecodedHi 3.1.1751.2.18.11.7.1.4
Outgoing cells from the i/o port to the outside media.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

dbCirEmIfStatsCellsDecodedLo 3.1.1751.2.18.11.7.1.5
Outgoing cells from the i/o port to the outside media.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

dbCirEmIfStatsTimer 3.1.1751.2.18.11.7.1.6
Time, in seconds, since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..899  

atmImaStatsTable 3.1.1751.2.18.11.8
Table of statistics for an atmIma interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmImaStatsEntry

atmImaStatsEntry 3.1.1751.2.18.11.8.1
Row definition for the atmIma statistics table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmImaStatsEntry  

atmImaStatsId 3.1.1751.2.18.11.8.1.1
Interface index (SSPPCCC) to the atmIma statistics table.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

atmImaStatsTimer 3.1.1751.2.18.11.8.1.2
Time, in seconds, since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmImaStatsImaViolations 3.1.1751.2.18.11.8.1.3
ICP violations: count of errored, invalid or missing ICP cells during non-SES-IMA condition.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmImaStatsOifAnomalies 3.1.1751.2.18.11.8.1.4
The number of OIF anomalies during non-SES-IMA condition at the near-end.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmImaStatsNeTxNumFailures 3.1.1751.2.18.11.8.1.5
The number of times a near-end transmit failure alarm condition has been entered on this link.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmImaStatsNeRxNumFailures 3.1.1751.2.18.11.8.1.6
The number of times a near-end receive failure alarm condition has been entered on this link (i.e., LIF, LODS, Mis-Connected, RDI-IMA).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmImaStatsFeTxNumFailures 3.1.1751.2.18.11.8.1.7
The number of times a far-end transmit failure alarm condition has been entered on this link.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmImaStatsFeRxNumFailures 3.1.1751.2.18.11.8.1.8
The number of times a far-end receive failure alarm condition has been entered on this link (i.e. LIF, LODS, Mis-Connected, RDI-IMA).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmImaStatsTxStuffs 3.1.1751.2.18.11.8.1.9
Counts of stuff events inserted in the transmit direction.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmImaStatsRxStuffs 3.1.1751.2.18.11.8.1.10
Counts of stuff events detected in the receive direction.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ilmiStatsTable 3.1.1751.2.18.11.9
Table of statistics for an ILMI enabled interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IlmiStatsEntry

ilmiStatsEntry 3.1.1751.2.18.11.9.1
Row definition for the ILMI statistics table.
Status: current Access: not-accessible
OBJECT-TYPE    
  IlmiStatsEntry  

ilmiStatsId 3.1.1751.2.18.11.9.1.1
Interface index (SSPPCCC) for the ILMI interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

ilmiStatsTimer 3.1.1751.2.18.11.9.1.2
Time, in seconds, since last statistics reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ilmiStatsLinkResets 3.1.1751.2.18.11.9.1.3
Times connectivity has toggled between down and up.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ilmiStatsAttachPtChanged 3.1.1751.2.18.11.9.1.4
Times Attachment Point change was detected.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ilmiStatsAttachPtVerified 3.1.1751.2.18.11.9.1.5
Times Attachment Point was verified successfully.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ilmiStatsSecureLnkProcInit 3.1.1751.2.18.11.9.1.6
Times Secure Link Procedure was initiated.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ilmiStatsColdStartRx 3.1.1751.2.18.11.9.1.7
Times Cold Start trap was received.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ilmiStatsColdStartTx 3.1.1751.2.18.11.9.1.8
Times Cold Start trap was transmitted.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ilmiStatsPduRx 3.1.1751.2.18.11.9.1.9
ilmi pdu received
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ilmiStatsPduTx 3.1.1751.2.18.11.9.1.10
ilmi pdu transmitted
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ilmiStatsReqTimeouts 3.1.1751.2.18.11.9.1.11
Times getRequest of any type timed out.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ilmiStatsPacketDisc 3.1.1751.2.18.11.9.1.12
Times a received packet was discarded.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vuniIlmiStatsTable 3.1.1751.2.18.11.12
Table of statistics for an ILMI enabled interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VuniIlmiStatsEntry

vuniIlmiStatsEntry 3.1.1751.2.18.11.12.1
Row definition for the ILMI statistics table.
Status: current Access: not-accessible
OBJECT-TYPE    
  VuniIlmiStatsEntry  

vuniIlmiStatsId 3.1.1751.2.18.11.12.1.1
Interface index (SSPPCCC) for the ILMI interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

vuniIlmiVUNIId 3.1.1751.2.18.11.12.1.2
Virtual UNI number, second index to access the ILMI on virtual UNI interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..255  

vuniIlmiStatsTimer 3.1.1751.2.18.11.12.1.3
Time, in seconds, since last statistics reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vuniIlmiStatsLinkResets 3.1.1751.2.18.11.12.1.4
Times connectivity has toggled between down and up.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vuniIlmiStatsAttachPtChanged 3.1.1751.2.18.11.12.1.5
Times Attachment Point change was detected.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vuniIlmiStatsAttachPtVerified 3.1.1751.2.18.11.12.1.6
Times Attachment Point was verified successfully.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vuniIlmiStatsSecureLnkProcInit 3.1.1751.2.18.11.12.1.7
Times Secure Link Procedure was initiated.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vuniIlmiStatsColdStartRx 3.1.1751.2.18.11.12.1.8
Times Cold Start trap was received.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vuniIlmiStatsColdStartTx 3.1.1751.2.18.11.12.1.9
Times Cold Start trap was transmitted.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vuniIlmiStatsPduRx 3.1.1751.2.18.11.12.1.10
vuniIlmi pdu received
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vuniIlmiStatsPduTx 3.1.1751.2.18.11.12.1.11
vuniIlmi pdu transmitted
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vuniIlmiStatsReqTimeouts 3.1.1751.2.18.11.12.1.12
Times getRequest of any type timed out.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vuniIlmiStatsPacketDisc 3.1.1751.2.18.11.12.1.13
Times a received packet was discarded.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vuniResetIlmiStatistics 3.1.1751.2.18.11.12.1.14
Reset the ATM ILMI statistics counters for the given channel Id (SSPPCCC) and vuni Id
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noAction(1), reset(2)  

atmPvcVccStatsTable 3.1.1751.2.18.12.1
Table of statistics for a channel connection
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmPvcVccStatsEntry

atmPvcVccStatsEntry 3.1.1751.2.18.12.1.1
Row definition for the connection statistics table
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmPvcVccStatsEntry  

atmPvcVccStatsIfA 3.1.1751.2.18.12.1.1.1
Interface index (SSPPCCC) on side A
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

atmPvcVccStatsVpiA 3.1.1751.2.18.12.1.1.2
VPI on side A
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..4095  

atmPvcVccStatsVciA 3.1.1751.2.18.12.1.1.3
VCI on side A
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..65535  

atmPvcVccStatsIfB 3.1.1751.2.18.12.1.1.4
Interface index (SSPPCCC) on side B
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

atmPvcVccStatsVpiB 3.1.1751.2.18.12.1.1.5
VPI on side B
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..4095  

atmPvcVccStatsVciB 3.1.1751.2.18.12.1.1.6
VCI on side B
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..65535  

atmPvcVccStatsInCellCountHiA 3.1.1751.2.18.12.1.1.7
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVccStatsInCellCountLoA 3.1.1751.2.18.12.1.1.8
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVccStatsOutCellCountHiA 3.1.1751.2.18.12.1.1.9
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVccStatsOutCellCountLoA 3.1.1751.2.18.12.1.1.10
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVccStatsInCellCountHiB 3.1.1751.2.18.12.1.1.11
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVccStatsInCellCountLoB 3.1.1751.2.18.12.1.1.12
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVccStatsOutCellCountHiB 3.1.1751.2.18.12.1.1.13
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVccStatsOutCellCountLoB 3.1.1751.2.18.12.1.1.14
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVccStatsTimer 3.1.1751.2.18.12.1.1.15
Number of seconds stats have been collecting
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVccStatsFrwdErrCrrctnRateA2B 3.1.1751.2.18.12.1.1.16
Displays the Forward error correction rate being used by the FEC module in the A2B direction. This field is dynamic when Auto rates are selected. In other cases, it will display the rate set by the user.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), eighthRate(2), quarterRate(3), halfRate(4)  

atmPvcVccStatsFrwdErrCrrctnRateB2A 3.1.1751.2.18.12.1.1.17
Displays the Forward error correction rate being used by the FEC module in the B2A direction. This field is dynamic when Auto rates are selected. In other cases, it will display the rate set by the user.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), eighthRate(2), quarterRate(3), halfRate(4)  

atmPvcVccStatsInOdometerCellCountHiA 3.1.1751.2.18.12.1.1.18
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVccStatsInOdometerCellCountLoA 3.1.1751.2.18.12.1.1.19
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVccStatsOutOdometerCellCountHiA 3.1.1751.2.18.12.1.1.20
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVccStatsOutOdometerCellCountLoA 3.1.1751.2.18.12.1.1.21
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVccStatsInOdometerCellCountHiB 3.1.1751.2.18.12.1.1.22
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVccStatsInOdometerCellCountLoB 3.1.1751.2.18.12.1.1.23
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVccStatsOutOdometerCellCountHiB 3.1.1751.2.18.12.1.1.24
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVccStatsOutOdometerCellCountLoB 3.1.1751.2.18.12.1.1.25
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVccStatsOdometerTimer 3.1.1751.2.18.12.1.1.26
Number of seconds since odometer was reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVccStatsOdometerReset 3.1.1751.2.18.12.1.1.27
Odometer reset button.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reset(1)  

atmPvcVccStatsOamAisTxA 3.1.1751.2.18.12.1.1.28
Number of AIS cells transmitted.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVccStatsOamAisRxA 3.1.1751.2.18.12.1.1.29
Number of AIS cells received.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVccStatsOamRdiTxA 3.1.1751.2.18.12.1.1.30
Number of RDI cells transmitted.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVccStatsOamRdiRxA 3.1.1751.2.18.12.1.1.31
Number of RDI cells received.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVccStatsOamAisTxB 3.1.1751.2.18.12.1.1.32
Number of AIS cells transmitted.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVccStatsOamAisRxB 3.1.1751.2.18.12.1.1.33
Number of AIS cells received.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVccStatsOamRdiTxB 3.1.1751.2.18.12.1.1.34
Number of RDI cells transmitted.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVccStatsOamRdiRxB 3.1.1751.2.18.12.1.1.35
Number of RDI cells received.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVccStatsCellsDroppedA 3.1.1751.2.18.12.1.1.36
Cells Dropped on the Incoming side of A
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVccStatsCellsTaggedA 3.1.1751.2.18.12.1.1.37
Cells Tagged on the Incoming side of A
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVccStatsCellsDroppedB 3.1.1751.2.18.12.1.1.38
Cells Dropped on the Incoming side of B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVccStatsCellsTaggedB 3.1.1751.2.18.12.1.1.39
Cells Tagged on the Incoming side of B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVpcStatsTable 3.1.1751.2.18.12.2
Table of statistics for a channel connection
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmPvcVpcStatsEntry

atmPvcVpcStatsEntry 3.1.1751.2.18.12.2.1
Row definition for the connection statistics table
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmPvcVpcStatsEntry  

atmPvcVpcStatsIfA 3.1.1751.2.18.12.2.1.1
Interface index (SSPPCCC) on side A
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

atmPvcVpcStatsVpiA 3.1.1751.2.18.12.2.1.2
VPI on side A
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..4095  

atmPvcVpcStatsIfB 3.1.1751.2.18.12.2.1.3
Interface index (SSPPCCC) on side A
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

atmPvcVpcStatsVpiB 3.1.1751.2.18.12.2.1.4
VPI on side B
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..4095  

atmPvcVpcStatsInCellCountHiA 3.1.1751.2.18.12.2.1.5
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVpcStatsInCellCountLoA 3.1.1751.2.18.12.2.1.6
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVpcStatsOutCellCountHiA 3.1.1751.2.18.12.2.1.7
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVpcStatsOutCellCountLoA 3.1.1751.2.18.12.2.1.8
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVpcStatsInCellCountHiB 3.1.1751.2.18.12.2.1.9
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVpcStatsInCellCountLoB 3.1.1751.2.18.12.2.1.10
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVpcStatsOutCellCountHiB 3.1.1751.2.18.12.2.1.11
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVpcStatsOutCellCountLoB 3.1.1751.2.18.12.2.1.12
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVpcStatsTimer 3.1.1751.2.18.12.2.1.13
Number of seconds stats have been collecting
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVpcStatsInOdometerCellCountHiA 3.1.1751.2.18.12.2.1.14
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVpcStatsInOdometerCellCountLoA 3.1.1751.2.18.12.2.1.15
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVpcStatsOutOdometerCellCountHiA 3.1.1751.2.18.12.2.1.16
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVpcStatsOutOdometerCellCountLoA 3.1.1751.2.18.12.2.1.17
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVpcStatsInOdometerCellCountHiB 3.1.1751.2.18.12.2.1.18
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVpcStatsInOdometerCellCountLoB 3.1.1751.2.18.12.2.1.19
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVpcStatsOutOdometerCellCountHiB 3.1.1751.2.18.12.2.1.20
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVpcStatsOutOdometerCellCountLoB 3.1.1751.2.18.12.2.1.21
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVpcStatsOdometerTimer 3.1.1751.2.18.12.2.1.22
Number of seconds since odometer was reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVpcStatsOdometerReset 3.1.1751.2.18.12.2.1.23
Odometer reset button.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reset(1)  

atmPvcVpcStatsOamAisTxA 3.1.1751.2.18.12.2.1.24
Number of AIS cells transmitted.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVpcStatsOamAisRxA 3.1.1751.2.18.12.2.1.25
Number of AIS cells received.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVpcStatsOamRdiTxA 3.1.1751.2.18.12.2.1.26
Number of RDI cells transmitted.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVpcStatsOamRdiRxA 3.1.1751.2.18.12.2.1.27
Number of RDI cells received.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVpcStatsOamAisTxB 3.1.1751.2.18.12.2.1.28
Number of AIS cells transmitted.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVpcStatsOamAisRxB 3.1.1751.2.18.12.2.1.29
Number of AIS cells received.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVpcStatsOamRdiTxB 3.1.1751.2.18.12.2.1.30
Number of RDI cells transmitted.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVpcStatsOamRdiRxB 3.1.1751.2.18.12.2.1.31
Number of RDI cells received.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVpcStatsCellsDroppedA 3.1.1751.2.18.12.2.1.32
Cells Dropped on the Incoming side of A
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVpcStatsCellsTaggedA 3.1.1751.2.18.12.2.1.33
Cells Tagged on the Incoming side of A
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVpcStatsCellsDroppedB 3.1.1751.2.18.12.2.1.34
Cells Dropped on the Incoming side of B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmPvcVpcStatsCellsTaggedB 3.1.1751.2.18.12.2.1.35
Cells Tagged on the Incoming side of B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSvcVccStatsTable 3.1.1751.2.18.12.3
Table of statistics for a channel connection
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmSvcVccStatsEntry

atmSvcVccStatsEntry 3.1.1751.2.18.12.3.1
Row definition for the connection statistics table
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmSvcVccStatsEntry  

atmSvcVccStatsIfA 3.1.1751.2.18.12.3.1.1
Interface index (SSPPCCC) on side A
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

atmSvcVccStatsVpiA 3.1.1751.2.18.12.3.1.2
VPI on side A
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..4095  

atmSvcVccStatsVciA 3.1.1751.2.18.12.3.1.3
VCI on side A
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..65535  

atmSvcVccStatsIfB 3.1.1751.2.18.12.3.1.4
Interface index (SSPPCCC) on side A
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

atmSvcVccStatsVpiB 3.1.1751.2.18.12.3.1.5
VPI on side B
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..4095  

atmSvcVccStatsVciB 3.1.1751.2.18.12.3.1.6
VCI on side B
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..65535  

atmSvcVccStatsInCellCountHiA 3.1.1751.2.18.12.3.1.7
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSvcVccStatsInCellCountLoA 3.1.1751.2.18.12.3.1.8
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSvcVccStatsOutCellCountHiA 3.1.1751.2.18.12.3.1.9
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSvcVccStatsOutCellCountLoA 3.1.1751.2.18.12.3.1.10
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSvcVccStatsInCellCountHiB 3.1.1751.2.18.12.3.1.11
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSvcVccStatsInCellCountLoB 3.1.1751.2.18.12.3.1.12
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSvcVccStatsOutCellCountHiB 3.1.1751.2.18.12.3.1.13
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSvcVccStatsOutCellCountLoB 3.1.1751.2.18.12.3.1.14
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSvcVccStatsTimer 3.1.1751.2.18.12.3.1.15
Number of seconds stats have been collecting
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSvcVccStatsInOdometerCellCountHiA 3.1.1751.2.18.12.3.1.16
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSvcVccStatsInOdometerCellCountLoA 3.1.1751.2.18.12.3.1.17
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSvcVccStatsOutOdometerCellCountHiA 3.1.1751.2.18.12.3.1.18
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSvcVccStatsOutOdometerCellCountLoA 3.1.1751.2.18.12.3.1.19
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSvcVccStatsInOdometerCellCountHiB 3.1.1751.2.18.12.3.1.20
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSvcVccStatsInOdometerCellCountLoB 3.1.1751.2.18.12.3.1.21
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSvcVccStatsOutOdometerCellCountHiB 3.1.1751.2.18.12.3.1.22
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSvcVccStatsOutOdometerCellCountLoB 3.1.1751.2.18.12.3.1.23
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSvcVccStatsOdometerTimer 3.1.1751.2.18.12.3.1.24
Number of seconds since odometer was reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSvcVccStatsOdometerReset 3.1.1751.2.18.12.3.1.25
Odometer reset button.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reset(1)  

atmSvcVccStatsCellsDroppedA 3.1.1751.2.18.12.3.1.26
Cells Dropped on the Incoming side of A
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSvcVccStatsCellsTaggedA 3.1.1751.2.18.12.3.1.27
Cells Tagged on the Incoming side of A
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSvcVccStatsCellsDroppedB 3.1.1751.2.18.12.3.1.28
Cells Dropped on the Incoming side of B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSvcVccStatsCellsTaggedB 3.1.1751.2.18.12.3.1.29
Cells Tagged on the Incoming side of B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAtmAppPvcVccStatsTable 3.1.1751.2.18.12.4
Table of Statistics entries
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IpAtmAppPvcVccStatsEntry

ipAtmAppPvcVccStatsEntry 3.1.1751.2.18.12.4.1
Row definition for statistics attribution.
Status: current Access: not-accessible
OBJECT-TYPE    
  IpAtmAppPvcVccStatsEntry  

ipAtmAppPvcVccStatsDestAddrA 3.1.1751.2.18.12.4.1.1
Statistics destination IP address
Status: current Access: not-accessible
OBJECT-TYPE    
  IpAddress  

ipAtmAppPvcVccStatsSubnetMaskA 3.1.1751.2.18.12.4.1.2
The subnet mask of the destination IP address. Value is an IP address.
Status: current Access: not-accessible
OBJECT-TYPE    
  IpAddress  

ipAtmAppPvcVccStatsIfB 3.1.1751.2.18.12.4.1.3
Interface index (SSPPCCC) on side B
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

ipAtmAppPvcVccStatsVpiB 3.1.1751.2.18.12.4.1.4
VPI on side B
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..4095  

ipAtmAppPvcVccStatsVciB 3.1.1751.2.18.12.4.1.5
VCI on side B
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..65535  

ipAtmAppPvcVccStatsInCellCountHiA 3.1.1751.2.18.12.4.1.6
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAtmAppPvcVccStatsInCellCountLoA 3.1.1751.2.18.12.4.1.7
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAtmAppPvcVccStatsOutCellCountHiA 3.1.1751.2.18.12.4.1.8
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAtmAppPvcVccStatsOutCellCountLoA 3.1.1751.2.18.12.4.1.9
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAtmAppPvcVccStatsFramesInB 3.1.1751.2.18.12.4.1.10
number of frames received on side B.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAtmAppPvcVccStatsFramesOutB 3.1.1751.2.18.12.4.1.11
number of frames sent from side B.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAtmAppPvcVccStatsInCellCountHiB 3.1.1751.2.18.12.4.1.12
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAtmAppPvcVccStatsInCellCountLoB 3.1.1751.2.18.12.4.1.13
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAtmAppPvcVccStatsOutCellCountHiB 3.1.1751.2.18.12.4.1.14
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAtmAppPvcVccStatsOutCellCountLoB 3.1.1751.2.18.12.4.1.15
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAtmAppPvcVccStatsTimer 3.1.1751.2.18.12.4.1.16
Number of seconds stats have been collecting
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAtmAppPvcVccStatsInOdometerCellCountHiA 3.1.1751.2.18.12.4.1.17
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAtmAppPvcVccStatsInOdometerCellCountLoA 3.1.1751.2.18.12.4.1.18
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAtmAppPvcVccStatsOutOdometerCellCountHiA 3.1.1751.2.18.12.4.1.19
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAtmAppPvcVccStatsOutOdometerCellCountLoA 3.1.1751.2.18.12.4.1.20
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAtmAppPvcVccStatsOdometerFramesInB 3.1.1751.2.18.12.4.1.21
Valid frames received at side B.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAtmAppPvcVccStatsOdometerFramesOutB 3.1.1751.2.18.12.4.1.22
Valid frames transmitted from side B.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAtmAppPvcVccStatsInOdometerCellCountHiB 3.1.1751.2.18.12.4.1.23
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAtmAppPvcVccStatsInOdometerCellCountLoB 3.1.1751.2.18.12.4.1.24
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAtmAppPvcVccStatsOutOdometerCellCountHiB 3.1.1751.2.18.12.4.1.25
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAtmAppPvcVccStatsOutOdometerCellCountLoB 3.1.1751.2.18.12.4.1.26
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAtmAppPvcVccStatsOdometerTimer 3.1.1751.2.18.12.4.1.27
Number of seconds since odometer was reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAtmAppPvcVccStatsOdometerReset 3.1.1751.2.18.12.4.1.28
Odometer reset button.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reset(1)  

ipAtmAppPvcVccStatsCellsDroppedB 3.1.1751.2.18.12.4.1.29
Cells Dropped on the Incoming side of B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAtmAppPvcVccStatsCellsTaggedB 3.1.1751.2.18.12.4.1.30
Cells Tagged on the Incoming side of B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAtmAppSvcVccStatsTable 3.1.1751.2.18.12.5
Table of statistics entries
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IpAtmAppSvcVccStatsEntry

ipAtmAppSvcVccStatsEntry 3.1.1751.2.18.12.5.1
Row definition of statistics attributes.
Status: current Access: not-accessible
OBJECT-TYPE    
  IpAtmAppSvcVccStatsEntry  

ipAtmAppSvcVccStatsDestAddrA 3.1.1751.2.18.12.5.1.1
Statistics destination IP address
Status: current Access: not-accessible
OBJECT-TYPE    
  IpAddress  

ipAtmAppSvcVccStatsSubnetMaskA 3.1.1751.2.18.12.5.1.2
The subnet mask of the destination IP address. Value is an IP address.
Status: current Access: not-accessible
OBJECT-TYPE    
  IpAddress  

ipAtmAppSvcVccStatsIfB 3.1.1751.2.18.12.5.1.3
Interface index (SSPPCCC) on side B
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

ipAtmAppSvcVccStatsVpiB 3.1.1751.2.18.12.5.1.4
VPI on side B
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..4095  

ipAtmAppSvcVccStatsVciB 3.1.1751.2.18.12.5.1.5
VCI on side B
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..65535  

ipAtmAppSvcVccStatsInCellCountHiA 3.1.1751.2.18.12.5.1.6
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAtmAppSvcVccStatsInCellCountLoA 3.1.1751.2.18.12.5.1.7
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAtmAppSvcVccStatsOutCellCountHiA 3.1.1751.2.18.12.5.1.8
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAtmAppSvcVccStatsOutCellCountLoA 3.1.1751.2.18.12.5.1.9
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAtmAppSvcVccStatsFramesInB 3.1.1751.2.18.12.5.1.10
Frames received at side B.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAtmAppSvcVccStatsFramesOutB 3.1.1751.2.18.12.5.1.11
Frames transmitted from side B.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAtmAppSvcVccStatsInCellCountHiB 3.1.1751.2.18.12.5.1.12
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAtmAppSvcVccStatsInCellCountLoB 3.1.1751.2.18.12.5.1.13
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAtmAppSvcVccStatsOutCellCountHiB 3.1.1751.2.18.12.5.1.14
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAtmAppSvcVccStatsOutCellCountLoB 3.1.1751.2.18.12.5.1.15
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAtmAppSvcVccStatsTimer 3.1.1751.2.18.12.5.1.16
Number of seconds stats have been collecting
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAtmAppSvcVccStatsCellsDroppedB 3.1.1751.2.18.12.5.1.17
Cells Dropped on the Incoming side of B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAtmAppSvcVccStatsCellsTaggedB 3.1.1751.2.18.12.5.1.18
Cells Tagged on the Incoming side of B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmPvcVccStatsTable 3.1.1751.2.18.12.6
Table of statistics for a channel connection
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CirEmAtmPvcVccStatsEntry

cirEmAtmPvcVccStatsEntry 3.1.1751.2.18.12.6.1
Row definition for the connection statistics table
Status: current Access: not-accessible
OBJECT-TYPE    
  CirEmAtmPvcVccStatsEntry  

cirEmAtmPvcVccStatsIfA 3.1.1751.2.18.12.6.1.1
Interface index (SSPPCCC) on side A
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

cirEmAtmPvcVccStatsIfB 3.1.1751.2.18.12.6.1.2
Interface index (SSPPCCC) on side A
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

cirEmAtmPvcVccStatsVpiB 3.1.1751.2.18.12.6.1.3
VPI on side B
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..4095  

cirEmAtmPvcVccStatsVciB 3.1.1751.2.18.12.6.1.4
VCI on side B
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..65535  

cirEmAtmPvcVccStatsCellsEncodedHiA 3.1.1751.2.18.12.6.1.5
Cells encoded on side A- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmPvcVccStatsCellsEncodedLoA 3.1.1751.2.18.12.6.1.6
Cells encoded on side A- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmPvcVccStatsCellsDecodedHiA 3.1.1751.2.18.12.6.1.7
Cells decoded on side A- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmPvcVccStatsCellsDecodedLoA 3.1.1751.2.18.12.6.1.8
Cells decoded on side A- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmPvcVccStatsInCellCountHiB 3.1.1751.2.18.12.6.1.9
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmPvcVccStatsInCellCountLoB 3.1.1751.2.18.12.6.1.10
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmPvcVccStatsOutCellCountHiB 3.1.1751.2.18.12.6.1.11
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmPvcVccStatsOutCellCountLoB 3.1.1751.2.18.12.6.1.12
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmPvcVccStatsTimer 3.1.1751.2.18.12.6.1.13
Number of seconds stats have been collecting
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmPvcVccStatsOdometerCellsEncodedHiA 3.1.1751.2.18.12.6.1.14
Cells encoded on side A- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmPvcVccStatsOdometerCellsEncodedLoA 3.1.1751.2.18.12.6.1.15
Cells encoded on side A- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmPvcVccStatsOdometerCellsDecodedHiA 3.1.1751.2.18.12.6.1.16
Cells decoded on side A- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmPvcVccStatsOdometerCellsDecodedLoA 3.1.1751.2.18.12.6.1.17
Cells decoded on side A- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmPvcVccStatsInOdometerCellCountHiB 3.1.1751.2.18.12.6.1.18
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmPvcVccStatsInOdometerCellCountLoB 3.1.1751.2.18.12.6.1.19
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmPvcVccStatsOutOdometerCellCountHiB 3.1.1751.2.18.12.6.1.20
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmPvcVccStatsOutOdometerCellCountLoB 3.1.1751.2.18.12.6.1.21
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmPvcVccStatsOdometerTimer 3.1.1751.2.18.12.6.1.22
Number of seconds since odometer was reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmPvcVccStatsOdometerReset 3.1.1751.2.18.12.6.1.23
Odometer reset button.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reset(1)  

cirEmAtmPvcVccStatsOamAisTx 3.1.1751.2.18.12.6.1.24
Number of AIS cells transmitted.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmPvcVccStatsOamAisRx 3.1.1751.2.18.12.6.1.25
Number of AIS cells received.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmPvcVccStatsOamRdiTx 3.1.1751.2.18.12.6.1.26
Number of RDI cells transmitted.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmPvcVccStatsOamRdiRx 3.1.1751.2.18.12.6.1.27
Number of RDI cells received.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmPvcVccStatsCellsDroppedB 3.1.1751.2.18.12.6.1.28
Cells Dropped on the Incoming side of B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmPvcVccStatsCellsTaggedB 3.1.1751.2.18.12.6.1.29
Cells Tagged on the Incoming side of B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmPvcVccStatsTable 3.1.1751.2.18.12.7
Table of statistics for a channel connection
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FrAtmPvcVccStatsEntry

frAtmPvcVccStatsEntry 3.1.1751.2.18.12.7.1
Row definition for the connection statistics table
Status: current Access: not-accessible
OBJECT-TYPE    
  FrAtmPvcVccStatsEntry  

frAtmPvcVccStatsIfA 3.1.1751.2.18.12.7.1.1
Interface index (SSPPCCC) on side A
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

frAtmPvcVccStatsDlciA 3.1.1751.2.18.12.7.1.2
dlci - side A
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..1023  

frAtmPvcVccStatsIfB 3.1.1751.2.18.12.7.1.3
Interface index (SSPPCCC) on side B
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

frAtmPvcVccStatsVpiB 3.1.1751.2.18.12.7.1.4
VPI on side B
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..4095  

frAtmPvcVccStatsVciB 3.1.1751.2.18.12.7.1.5
VCI on side B
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..65535  

frAtmPvcVccStatsCellsEncodedHiA 3.1.1751.2.18.12.7.1.6
Cells encoded on side A- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmPvcVccStatsCellsEncodedLoA 3.1.1751.2.18.12.7.1.7
Cells encoded on side A- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmPvcVccStatsCellsDecodedHiA 3.1.1751.2.18.12.7.1.8
Cells decoded on side A- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmPvcVccStatsCellsDecodedLoA 3.1.1751.2.18.12.7.1.9
Cells decoded on side A- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmPvcVccStatsInCellCountHiB 3.1.1751.2.18.12.7.1.10
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmPvcVccStatsInCellCountLoB 3.1.1751.2.18.12.7.1.11
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmPvcVccStatsOutCellCountHiB 3.1.1751.2.18.12.7.1.12
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmPvcVccStatsOutCellCountLoB 3.1.1751.2.18.12.7.1.13
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmPvcVccStatsTimer 3.1.1751.2.18.12.7.1.14
Number of seconds stats have been collecting
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmPvcVccStatsFramesDroppedA 3.1.1751.2.18.12.7.1.15
Number of frames dropped for a given DLCI for A2B direction, only applicable to the input side.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmPvcVccStatsOdometerCellsEncodedHiA 3.1.1751.2.18.12.7.1.16
Cells encoded on side A- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmPvcVccStatsOdometerCellsEncodedLoA 3.1.1751.2.18.12.7.1.17
Cells encoded on side A- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmPvcVccStatsOdometerCellsDecodedHiA 3.1.1751.2.18.12.7.1.18
Cells decoded on side A- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmPvcVccStatsOdometerCellsDecodedLoA 3.1.1751.2.18.12.7.1.19
Cells decoded on side A- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmPvcVccStatsInOdometerCellCountHiB 3.1.1751.2.18.12.7.1.20
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmPvcVccStatsInOdometerCellCountLoB 3.1.1751.2.18.12.7.1.21
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmPvcVccStatsOutOdometerCellCountHiB 3.1.1751.2.18.12.7.1.22
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmPvcVccStatsOutOdometerCellCountLoB 3.1.1751.2.18.12.7.1.23
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmPvcVccStatsOdometerTimer 3.1.1751.2.18.12.7.1.24
Number of seconds since odometer was reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmPvcVccStatsOdometerFramesDroppedA 3.1.1751.2.18.12.7.1.25
Number of frames dropped for a given DLCI for A2B direction, only applicable to the input side.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmPvcVccStatsOdometerReset 3.1.1751.2.18.12.7.1.26
Odometer reset button.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reset(1)  

frAtmPvcVccStatsOamAisTx 3.1.1751.2.18.12.7.1.27
Number of AIS cells transmitted.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmPvcVccStatsOamAisRx 3.1.1751.2.18.12.7.1.28
Number of AIS cells received.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmPvcVccStatsOamRdiTx 3.1.1751.2.18.12.7.1.29
Number of RDI cells transmitted.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmPvcVccStatsOamRdiRx 3.1.1751.2.18.12.7.1.30
Number of RDI cells received.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmPvcVccStatsAal5ErrFramesA 3.1.1751.2.18.12.7.1.31
Number of Aal5 Errored Frames, which are not dropped due to UPC in A2B dir, only applicable to Input Side
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmPvcVccStatsFramesTaggedA 3.1.1751.2.18.12.7.1.32
Number of Frames tagged due to UPC in A2B dir, only applicable to Input Side
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmPvcVccStatsCellsDroppedB 3.1.1751.2.18.12.7.1.33
Cells Dropped on the Incoming side of B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frAtmPvcVccStatsCellsTaggedB 3.1.1751.2.18.12.7.1.34
Cells Tagged on the Incoming side of B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frFrPvcStatsTable 3.1.1751.2.18.12.8
Table of statistics for a channel connection
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FrFrPvcStatsEntry

frFrPvcStatsEntry 3.1.1751.2.18.12.8.1
Row definition for the connection statistics table
Status: current Access: not-accessible
OBJECT-TYPE    
  FrFrPvcStatsEntry  

frFrPvcStatsIfA 3.1.1751.2.18.12.8.1.1
Interface index (SSPPCCC) on side A
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

frFrPvcStatsDlciA 3.1.1751.2.18.12.8.1.2
dlci - side A
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..1023  

frFrPvcStatsIfB 3.1.1751.2.18.12.8.1.3
Interface index (SSPPCCC) on side B
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

frFrPvcStatsDlciB 3.1.1751.2.18.12.8.1.4
dlci - side B
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..1023  

frFrPvcStatsCellsEncodedHiA 3.1.1751.2.18.12.8.1.5
Cells encoded on side A- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frFrPvcStatsCellsEncodedLoA 3.1.1751.2.18.12.8.1.6
Cells encoded on side A- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frFrPvcStatsCellsDecodedHiA 3.1.1751.2.18.12.8.1.7
Cells decoded on side A- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frFrPvcStatsCellsDecodedLoA 3.1.1751.2.18.12.8.1.8
Cells decoded on side A- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frFrPvcStatsCellsEncodedHiB 3.1.1751.2.18.12.8.1.9
Cells encoded on side B- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frFrPvcStatsCellsEncodedLoB 3.1.1751.2.18.12.8.1.10
Cells encoded on side B- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frFrPvcStatsCellsDecodedHiB 3.1.1751.2.18.12.8.1.11
Cells decoded on side B- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frFrPvcStatsCellsDecodedLoB 3.1.1751.2.18.12.8.1.12
Cells decoded on side B- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frFrPvcStatsTimer 3.1.1751.2.18.12.8.1.13
Number of seconds stats have been collecting
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frFrPvcStatsFramesDroppedA 3.1.1751.2.18.12.8.1.14
Number of frames dropped for a given DLCI for A2B direction, only applicable to the input side.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frFrPvcStatsFramesDroppedB 3.1.1751.2.18.12.8.1.15
Number of frames dropped for a given DLCI for B2A direction, only applicable to the input side.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frFrPvcStatsOdometerCellsEncodedHiA 3.1.1751.2.18.12.8.1.16
Cells encoded on side A- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frFrPvcStatsOdometerCellsEncodedLoA 3.1.1751.2.18.12.8.1.17
Cells encoded on side A- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frFrPvcStatsOdometerCellsDecodedHiA 3.1.1751.2.18.12.8.1.18
Cells decoded on side A- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frFrPvcStatsOdometerCellsDecodedLoA 3.1.1751.2.18.12.8.1.19
Cells decoded on side A- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frFrPvcStatsOdometerCellsEncodedHiB 3.1.1751.2.18.12.8.1.20
Cells encoded on side B- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frFrPvcStatsOdometerCellsEncodedLoB 3.1.1751.2.18.12.8.1.21
Cells encoded on side B- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frFrPvcStatsOdometerCellsDecodedHiB 3.1.1751.2.18.12.8.1.22
Cells decoded on side B- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frFrPvcStatsOdometerCellsDecodedLoB 3.1.1751.2.18.12.8.1.23
Cells decoded on side B- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frFrPvcStatsOdometerTimer 3.1.1751.2.18.12.8.1.24
Number of seconds since odometer was reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frFrPvcStatsOdometerFramesDroppedA 3.1.1751.2.18.12.8.1.25
Number of frames dropped for a given DLCI for A2B direction, only applicable to the input side.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frFrPvcStatsOdometerFramesDroppedB 3.1.1751.2.18.12.8.1.26
Number of frames dropped for a given DLCI for B2A direction, only applicable to the input side.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frFrPvcStatsOdometerReset 3.1.1751.2.18.12.8.1.27
Odometer reset button.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reset(1)  

frFrPvcStatsAal5ErrFramesA 3.1.1751.2.18.12.8.1.28
Number of Aal5 Errored Frames, which are not dropped due to UPC in A2B dir, only applicable to Input Side
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frFrPvcStatsAal5ErrFramesB 3.1.1751.2.18.12.8.1.29
Number of Aal5 Errored Frames, which are not dropped due to UPC in B2A dir, only applicable to Input Side
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frFrPvcStatsFramesTaggedA 3.1.1751.2.18.12.8.1.30
Number of Frames tagged due to UPC in A2B dir, only applicable to Input Side
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frFrPvcStatsFramesTaggedB 3.1.1751.2.18.12.8.1.31
Number of Frames tagged due to UPC in B2A dir, only applicable to Input Side
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmPvcVccStatsTable 3.1.1751.2.18.12.9
Table of statistics for a channel connection
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VbrAtmPvcVccStatsEntry

vbrAtmPvcVccStatsEntry 3.1.1751.2.18.12.9.1
Row definition for the connection statistics table
Status: current Access: not-accessible
OBJECT-TYPE    
  VbrAtmPvcVccStatsEntry  

vbrAtmPvcVccStatsIfA 3.1.1751.2.18.12.9.1.1
Interface index (SSPPCCC) on side A
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

vbrAtmPvcVccStatsIfB 3.1.1751.2.18.12.9.1.2
Interface index (SSPPCCC) on side A
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

vbrAtmPvcVccStatsVpiB 3.1.1751.2.18.12.9.1.3
vpi - side B
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..4095  

vbrAtmPvcVccStatsVciB 3.1.1751.2.18.12.9.1.4
vci - side B
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..65535  

vbrAtmPvcVccStatsCellsEncodedHiA 3.1.1751.2.18.12.9.1.5
Cells encoded on side A- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmPvcVccStatsCellsEncodedLoA 3.1.1751.2.18.12.9.1.6
Cells encoded on side A- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmPvcVccStatsCellsDecodedHiA 3.1.1751.2.18.12.9.1.7
Cells decoded on side A- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmPvcVccStatsCellsDecodedLoA 3.1.1751.2.18.12.9.1.8
Cells decoded on side A- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmPvcVccStatsInCellCountHiB 3.1.1751.2.18.12.9.1.10
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmPvcVccStatsInCellCountLoB 3.1.1751.2.18.12.9.1.11
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmPvcVccStatsOutCellCountHiB 3.1.1751.2.18.12.9.1.12
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmPvcVccStatsOutCellCountLoB 3.1.1751.2.18.12.9.1.13
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmPvcVccStatsTimer 3.1.1751.2.18.12.9.1.14
Number of seconds stats have been collecting
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmPvcVccStatsOdometerCellsEncodedHiA 3.1.1751.2.18.12.9.1.15
Cells encoded on side A- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmPvcVccStatsOdometerCellsEncodedLoA 3.1.1751.2.18.12.9.1.16
Cells encoded on side A- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmPvcVccStatsOdometerCellsDecodedHiA 3.1.1751.2.18.12.9.1.17
Cells decoded on side A- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmPvcVccStatsOdometerCellsDecodedLoA 3.1.1751.2.18.12.9.1.18
Cells decoded on side A- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmPvcVccStatsInOdometerCellCountHiB 3.1.1751.2.18.12.9.1.19
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmPvcVccStatsInOdometerCellCountLoB 3.1.1751.2.18.12.9.1.20
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmPvcVccStatsOutOdometerCellCountHiB 3.1.1751.2.18.12.9.1.21
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmPvcVccStatsOutOdometerCellCountLoB 3.1.1751.2.18.12.9.1.22
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmPvcVccStatsOdometerTimer 3.1.1751.2.18.12.9.1.23
Number of seconds since odometer was reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmPvcVccStatsOdometerReset 3.1.1751.2.18.12.9.1.24
Odometer reset button.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reset(1)  

vbrAtmPvcVccStatsOamAisTx 3.1.1751.2.18.12.9.1.25
Number of AIS cells transmitted.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmPvcVccStatsOamAisRx 3.1.1751.2.18.12.9.1.26
Number of AIS cells received.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmPvcVccStatsOamRdiTx 3.1.1751.2.18.12.9.1.27
Number of RDI cells transmitted.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmPvcVccStatsOamRdiRx 3.1.1751.2.18.12.9.1.28
Number of RDI cells received.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmPvcVccStatsCellsDroppedB 3.1.1751.2.18.12.9.1.29
Cells Dropped on the Incoming side of B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmPvcVccStatsCellsTaggedB 3.1.1751.2.18.12.9.1.30
Cells Tagged on the Incoming side of B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmCirEmPvcStatsTable 3.1.1751.2.18.12.10
Table of statistics for a channel connection
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CirEmCirEmPvcStatsEntry

cirEmCirEmPvcStatsEntry 3.1.1751.2.18.12.10.1
Row definition for the connection statistics table
Status: current Access: not-accessible
OBJECT-TYPE    
  CirEmCirEmPvcStatsEntry  

cirEmCirEmPvcStatsIfA 3.1.1751.2.18.12.10.1.1
Interface index (SSPPCCC) on side A
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

cirEmCirEmPvcStatsIfB 3.1.1751.2.18.12.10.1.2
Interface index (SSPPCCC) on side A
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

cirEmCirEmPvcStatsCellsEncodedHiA 3.1.1751.2.18.12.10.1.3
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmCirEmPvcStatsCellsEncodedLoA 3.1.1751.2.18.12.10.1.4
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmCirEmPvcStatsCellsDecodedHiA 3.1.1751.2.18.12.10.1.5
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmCirEmPvcStatsCellsDecodedLoA 3.1.1751.2.18.12.10.1.6
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmCirEmPvcStatsCellsEncodedHiB 3.1.1751.2.18.12.10.1.7
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmCirEmPvcStatsCellsEncodedLoB 3.1.1751.2.18.12.10.1.8
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmCirEmPvcStatsCellsDecodedHiB 3.1.1751.2.18.12.10.1.9
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmCirEmPvcStatsCellsDecodedLoB 3.1.1751.2.18.12.10.1.10
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmCirEmPvcStatsTimer 3.1.1751.2.18.12.10.1.11
Number of seconds stats have been collecting
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmCirEmPvcStatsOdometerCellsEncodedHiA 3.1.1751.2.18.12.10.1.12
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmCirEmPvcStatsOdometerCellsEncodedLoA 3.1.1751.2.18.12.10.1.13
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmCirEmPvcStatsOdometerCellsDecodedHiA 3.1.1751.2.18.12.10.1.14
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmCirEmPvcStatsOdometerCellsDecodedLoA 3.1.1751.2.18.12.10.1.15
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmCirEmPvcStatsOdometerCellsEncodedHiB 3.1.1751.2.18.12.10.1.16
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmCirEmPvcStatsOdometerCellsEncodedLoB 3.1.1751.2.18.12.10.1.17
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmCirEmPvcStatsOdometerCellsDecodedHiB 3.1.1751.2.18.12.10.1.18
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmCirEmPvcStatsOdometerCellsDecodedLoB 3.1.1751.2.18.12.10.1.19
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmCirEmPvcStatsOdometerTimer 3.1.1751.2.18.12.10.1.20
Number of seconds since odometer was reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmCirEmPvcStatsOdometerReset 3.1.1751.2.18.12.10.1.21
Odometer reset button.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reset(1)  

vbrVbrPvcStatsTable 3.1.1751.2.18.12.11
Table of statistics for a channel connection
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VbrVbrPvcStatsEntry

vbrVbrPvcStatsEntry 3.1.1751.2.18.12.11.1
Row definition for the connection statistics table
Status: current Access: not-accessible
OBJECT-TYPE    
  VbrVbrPvcStatsEntry  

vbrVbrPvcStatsIfA 3.1.1751.2.18.12.11.1.1
Interface index (SSPPCCC) on side A
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

vbrVbrPvcStatsIfB 3.1.1751.2.18.12.11.1.2
Interface index (SSPPCCC) on side A
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

vbrVbrPvcStatsCellsEncodedHiA 3.1.1751.2.18.12.11.1.4
Cells encoded on side A- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrVbrPvcStatsCellsEncodedLoA 3.1.1751.2.18.12.11.1.5
Cells encoded on side A- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrVbrPvcStatsCellsDecodedHiA 3.1.1751.2.18.12.11.1.6
Cells decoded on side A- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrVbrPvcStatsCellsDecodedLoA 3.1.1751.2.18.12.11.1.7
Cells decoded on side A- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrVbrPvcStatsCellsEncodedHiB 3.1.1751.2.18.12.11.1.9
Cells encoded on side B- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrVbrPvcStatsCellsEncodedLoB 3.1.1751.2.18.12.11.1.10
Cells encoded on side B- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrVbrPvcStatsCellsDecodedHiB 3.1.1751.2.18.12.11.1.11
Cells decoded on side B- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrVbrPvcStatsCellsDecodedLoB 3.1.1751.2.18.12.11.1.12
Cells decoded on side B- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrVbrPvcStatsTimer 3.1.1751.2.18.12.11.1.13
Number of seconds stats have been collecting
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrVbrPvcStatsOdometerCellsEncodedHiA 3.1.1751.2.18.12.11.1.14
Cells encoded on side A- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrVbrPvcStatsOdometerCellsEncodedLoA 3.1.1751.2.18.12.11.1.15
Cells encoded on side A- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrVbrPvcStatsOdometerCellsDecodedHiA 3.1.1751.2.18.12.11.1.16
Cells decoded on side A- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrVbrPvcStatsOdometerCellsDecodedLoA 3.1.1751.2.18.12.11.1.17
Cells decoded on side A- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrVbrPvcStatsOdometerCellsEncodedHiB 3.1.1751.2.18.12.11.1.18
Cells encoded on side B- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrVbrPvcStatsOdometerCellsEncodedLoB 3.1.1751.2.18.12.11.1.19
Cells encoded on side B- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrVbrPvcStatsOdometerCellsDecodedHiB 3.1.1751.2.18.12.11.1.20
Cells decoded on side B- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrVbrPvcStatsOdometerCellsDecodedLoB 3.1.1751.2.18.12.11.1.21
Cells decoded on side B- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrVbrPvcStatsOdometerTimer 3.1.1751.2.18.12.11.1.22
Number of seconds since odometer was reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrVbrPvcStatsOdometerReset 3.1.1751.2.18.12.11.1.23
Odometer reset button.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reset(1)  

bridgeBridgePvcStatsTable 3.1.1751.2.18.12.12
Table of bridge-bridge PVC connection statistics
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    BridgeBridgePvcStatsEntry

bridgeBridgePvcStatsEntry 3.1.1751.2.18.12.12.1
Row definition of statistics attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  BridgeBridgePvcStatsEntry  

bridgeBridgePvcStatsIfA 3.1.1751.2.18.12.12.1.1
Interface index (SSPPCCC) on side A
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

bridgeBridgePvcStatsIfB 3.1.1751.2.18.12.12.1.2
Interface index (SSPPCCC) on side B
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

bridgeBridgePvcStatsCellsEncodedHiA 3.1.1751.2.18.12.12.1.3
Cells encoded on side A - (High order portion )
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeBridgePvcStatsCellsEncodedLoA 3.1.1751.2.18.12.12.1.4
Cells encoded on side A - ( Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeBridgePvcStatsCellsDecodedHiA 3.1.1751.2.18.12.12.1.5
Cells decoded on side A - ( High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeBridgePvcStatsCellsDecodedLoA 3.1.1751.2.18.12.12.1.6
Cells decoded on side A - (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeBridgePvcStatsCellsEncodedHiB 3.1.1751.2.18.12.12.1.7
Cells encoded on side B - (High order portion )
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeBridgePvcStatsCellsEncodedLoB 3.1.1751.2.18.12.12.1.8
Cells encoded on side B - (Low order portion )
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeBridgePvcStatsCellsDecodedHiB 3.1.1751.2.18.12.12.1.9
Cells decoded on side B - (High order portion )
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeBridgePvcStatsCellsDecodedLoB 3.1.1751.2.18.12.12.1.10
Cells decoded on side B -(Low order portion )
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeBridgePvcStatsTimer 3.1.1751.2.18.12.12.1.11
Number of seconds stats have been collecting
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeBridgePvcStatsOdometerCellsEncodedHiA 3.1.1751.2.18.12.12.1.12
Cells encoded on side A- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeBridgePvcStatsOdometerCellsEncodedLoA 3.1.1751.2.18.12.12.1.13
Cells encoded on side A- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeBridgePvcStatsOdometerCellsDecodedHiA 3.1.1751.2.18.12.12.1.14
Cells decoded on side A- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeBridgePvcStatsOdometerCellsDecodedLoA 3.1.1751.2.18.12.12.1.15
Cells decoded on side A- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeBridgePvcStatsOdometerCellsEncodedHiB 3.1.1751.2.18.12.12.1.16
Cells encoded on side B - (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeBridgePvcStatsOdometerCellsEncodedLoB 3.1.1751.2.18.12.12.1.17
Cells encoded on side B - (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeBridgePvcStatsOdometerCellsDecodedHiB 3.1.1751.2.18.12.12.1.18
Cells decoded on side B - (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeBridgePvcStatsOdometerCellsDecodedLoB 3.1.1751.2.18.12.12.1.19
Cells decoded on side B - (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeBridgePvcStatsOdometerTimer 3.1.1751.2.18.12.12.1.20
Number of seconds since odometer was reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeBridgePvcStatsOdometerReset 3.1.1751.2.18.12.12.1.21
Odometer reset button.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reset(1)  

bridgeAtmPvcVccStatsTable 3.1.1751.2.18.12.13
Table of statisics
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    BridgeAtmPvcVccStatsEntry

bridgeAtmPvcVccStatsEntry 3.1.1751.2.18.12.13.1
Row definition for the connection statistics table
Status: current Access: not-accessible
OBJECT-TYPE    
  BridgeAtmPvcVccStatsEntry  

bridgeAtmPvcVccStatsIfA 3.1.1751.2.18.12.13.1.1
Interface index (SSPPCCC) on side A
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

bridgeAtmPvcVccStatsIfB 3.1.1751.2.18.12.13.1.2
Interface index (SSPPCCC) on side B
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

bridgeAtmPvcVccStatsVpiB 3.1.1751.2.18.12.13.1.3
vpi - side B
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..4095  

bridgeAtmPvcVccStatsVciB 3.1.1751.2.18.12.13.1.4
vci - side B
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..65535  

bridgeAtmPvcVccStatsCellsEncodedHiA 3.1.1751.2.18.12.13.1.5
number of cells encoded on side A - (High order portion).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeAtmPvcVccStatsCellsEncodedLoA 3.1.1751.2.18.12.13.1.6
number of cells encoded on side A - (Low order portion).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeAtmPvcVccStatsCellsDecodedHiA 3.1.1751.2.18.12.13.1.7
number of cells decoded on side A - (High order portion).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeAtmPvcVccStatsCellsDecodedLoA 3.1.1751.2.18.12.13.1.8
number of cells decoded on side A - (Low order portion).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeAtmPvcVccStatsInCellCountHiB 3.1.1751.2.18.12.13.1.9
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeAtmPvcVccStatsInCellCountLoB 3.1.1751.2.18.12.13.1.10
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeAtmPvcVccStatsOutCellCountHiB 3.1.1751.2.18.12.13.1.11
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeAtmPvcVccStatsOutCellCountLoB 3.1.1751.2.18.12.13.1.12
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeAtmPvcVccStatsTimer 3.1.1751.2.18.12.13.1.13
Number of seconds stats have been collecting
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeAtmPvcVccStatsOdometerCellsEncodedHiA 3.1.1751.2.18.12.13.1.14
Cells encoded on side A- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeAtmPvcVccStatsOdometerCellsEncodedLoA 3.1.1751.2.18.12.13.1.15
Cells encoded on side A- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeAtmPvcVccStatsOdometerCellsDecodedHiA 3.1.1751.2.18.12.13.1.16
Cells decoded on side A- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeAtmPvcVccStatsOdometerCellsDecodedLoA 3.1.1751.2.18.12.13.1.17
Cells decoded on side A- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeAtmPvcVccStatsInOdometerCellCountHiB 3.1.1751.2.18.12.13.1.18
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeAtmPvcVccStatsInOdometerCellCountLoB 3.1.1751.2.18.12.13.1.19
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeAtmPvcVccStatsOutOdometerCellCountHiB 3.1.1751.2.18.12.13.1.20
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeAtmPvcVccStatsOutOdometerCellCountLoB 3.1.1751.2.18.12.13.1.21
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeAtmPvcVccStatsOdometerTimer 3.1.1751.2.18.12.13.1.22
Number of seconds since odometer was reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeAtmPvcVccStatsOdometerReset 3.1.1751.2.18.12.13.1.23
Odometer reset button.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reset(1)  

bridgeAtmPvcVccStatsOamAisTx 3.1.1751.2.18.12.13.1.24
Number of AIS cells transmitted.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeAtmPvcVccStatsOamAisRx 3.1.1751.2.18.12.13.1.25
Number of AIS cells received.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeAtmPvcVccStatsOamRdiTx 3.1.1751.2.18.12.13.1.26
Number of RDI cells transmitted.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeAtmPvcVccStatsOamRdiRx 3.1.1751.2.18.12.13.1.27
Number of RDI cells received.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeAtmPvcVccStatsCellsDroppedB 3.1.1751.2.18.12.13.1.28
Cells Dropped on the Incoming side of B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeAtmPvcVccStatsCellsTaggedB 3.1.1751.2.18.12.13.1.29
Cells Tagged on the Incoming side of B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmSpvcVccStatsTable 3.1.1751.2.18.12.14
Table of statistics for a CES SPVC channel connection
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CirEmAtmSpvcVccStatsEntry

cirEmAtmSpvcVccStatsEntry 3.1.1751.2.18.12.14.1
Row definition for the CES SPVC connection statistics table
Status: current Access: not-accessible
OBJECT-TYPE    
  CirEmAtmSpvcVccStatsEntry  

cirEmAtmSpvcVccStatsIfA 3.1.1751.2.18.12.14.1.1
Interface index for side A, the circuit emulation side, of a circuit emulation-atm SPVC VCC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

cirEmAtmSpvcVccStatsIfB 3.1.1751.2.18.12.14.1.2
Interface index for side B, the atm side, of a circuit emulation-atm SPVC VCC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

cirEmAtmSpvcVccStatsVpiB 3.1.1751.2.18.12.14.1.3
VPI value for side B, the atm side, of a circuit emulation-atm SPVC VCC connection. Valid range is a number between 0 and 4095.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..4095  

cirEmAtmSpvcVccStatsVciB 3.1.1751.2.18.12.14.1.4
VCI value for side B, the atm side, of a circuit emulation-atm SPVC VCC connection. Valid range is a number between 0 and 65535.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..65535  

cirEmAtmSpvcVccStatsCellsEncodedHiA 3.1.1751.2.18.12.14.1.5
Cells encoded on side A - (High order portion )
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmSpvcVccStatsCellsEncodedLoA 3.1.1751.2.18.12.14.1.6
Cells encoded on side A - ( Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmSpvcVccStatsCellsDecodedHiA 3.1.1751.2.18.12.14.1.7
Cells decoded on side A - ( High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmSpvcVccStatsCellsDecodedLoA 3.1.1751.2.18.12.14.1.8
Cells decoded on side A - (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmSpvcVccStatsInCellCountHiB 3.1.1751.2.18.12.14.1.9
Valid Cells received on B - (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmSpvcVccStatsInCellCountLoB 3.1.1751.2.18.12.14.1.10
Valid Cells received on B - (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmSpvcVccStatsOutCellCountHiB 3.1.1751.2.18.12.14.1.11
Valid cells transmitted on B - (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmSpvcVccStatsOutCellCountLoB 3.1.1751.2.18.12.14.1.12
Valid cells transmitted on B - (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmSpvcVccStatsTimer 3.1.1751.2.18.12.14.1.13
Number of seconds since stats have been collecting
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmSpvcVccStatsOdometerCellsEncodedHiA 3.1.1751.2.18.12.14.1.14
Cells encoded on side A- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmSpvcVccStatsOdometerCellsEncodedLoA 3.1.1751.2.18.12.14.1.15
Cells encoded on side A- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmSpvcVccStatsOdometerCellsDecodedHiA 3.1.1751.2.18.12.14.1.16
Cells decoded on side A- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmSpvcVccStatsOdometerCellsDecodedLoA 3.1.1751.2.18.12.14.1.17
Cells decoded on side A- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmSpvcVccStatsInOdometerCellCountHiB 3.1.1751.2.18.12.14.1.18
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmSpvcVccStatsInOdometerCellCountLoB 3.1.1751.2.18.12.14.1.19
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmSpvcVccStatsOutOdometerCellCountHiB 3.1.1751.2.18.12.14.1.20
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmSpvcVccStatsOutOdometerCellCountLoB 3.1.1751.2.18.12.14.1.21
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmSpvcVccStatsOdometerTimer 3.1.1751.2.18.12.14.1.22
Number of seconds since odometer was reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmSpvcVccStatsOdometerReset 3.1.1751.2.18.12.14.1.23
Odometer reset button.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reset(1)  

cirEmAtmSpvcVccStatsCellsDroppedB 3.1.1751.2.18.12.14.1.24
Cells Dropped on the Incoming side of B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cirEmAtmSpvcVccStatsCellsTaggedB 3.1.1751.2.18.12.14.1.25
Cells Tagged on the Incoming side of B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcVccStatsTable 3.1.1751.2.18.12.15
Table of statistics for a TE SPVC channel connection.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VbrAtmSpvcVccStatsEntry

vbrAtmSpvcVccStatsEntry 3.1.1751.2.18.12.15.1
Row definition for the TE SPVC connection statistics table.
Status: current Access: not-accessible
OBJECT-TYPE    
  VbrAtmSpvcVccStatsEntry  

vbrAtmSpvcVccStatsIfA 3.1.1751.2.18.12.15.1.1
Interface index for side A, the variable bit rate side, of a variable bit rate-atm SPVC VCC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

vbrAtmSpvcVccStatsIfB 3.1.1751.2.18.12.15.1.2
Interface index for side B, the atm side, of a variable bit rate-atm SPVC VCC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

vbrAtmSpvcVccStatsVpiB 3.1.1751.2.18.12.15.1.3
VPI value for side B, the atm side, of a variable bit rate-atm SPVC VCC connection. Valid range is a number between 0 and 4095.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..4095  

vbrAtmSpvcVccStatsVciB 3.1.1751.2.18.12.15.1.4
VCI value for side B, the atm side, of a variable bit rate-atm SPVC VCC connection. Valid range is a number between 0 and 65535.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..65535  

vbrAtmSpvcVccStatsCellsEncodedHiA 3.1.1751.2.18.12.15.1.5
Cells encoded on side A- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcVccStatsCellsEncodedLoA 3.1.1751.2.18.12.15.1.6
ells encoded on side A - (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcVccStatsCellsDecodedHiA 3.1.1751.2.18.12.15.1.7
Cells decoded on side A - (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcVccStatsCellsDecodedLoA 3.1.1751.2.18.12.15.1.8
Cells decoded on side A - (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcVccStatsInCellCountHiB 3.1.1751.2.18.12.15.1.9
Valid Cells received on B - (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcVccStatsInCellCountLoB 3.1.1751.2.18.12.15.1.10
Valid Cells received on B - (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcVccStatsOutCellCountHiB 3.1.1751.2.18.12.15.1.11
Valid cells transmitted on B -(High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcVccStatsOutCellCountLoB 3.1.1751.2.18.12.15.1.12
Valid cells transmitted on B - (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcVccStatsTimer 3.1.1751.2.18.12.15.1.13
Number of seconds stats have been collecting
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcVccStatsOdometerCellsEncodedHiA 3.1.1751.2.18.12.15.1.14
Cells encoded on side A- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcVccStatsOdometerCellsEncodedLoA 3.1.1751.2.18.12.15.1.15
Cells encoded on side A- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcVccStatsOdometerCellsDecodedHiA 3.1.1751.2.18.12.15.1.16
Cells decoded on side A- (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcVccStatsOdometerCellsDecodedLoA 3.1.1751.2.18.12.15.1.17
Cells decoded on side A- (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcVccStatsInOdometerCellCountHiB 3.1.1751.2.18.12.15.1.18
Valid Cells received on B - (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcVccStatsInOdometerCellCountLoB 3.1.1751.2.18.12.15.1.19
Valid Cells received on B - (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcVccStatsOutOdometerCellCountHiB 3.1.1751.2.18.12.15.1.20
Valid Cells transmitted on B -(High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcVccStatsOutOdometerCellCountLoB 3.1.1751.2.18.12.15.1.21
Valid Cells transmitted on B -(Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcVccStatsOdometerTimer 3.1.1751.2.18.12.15.1.22
Number of seconds since odometer was reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcVccStatsOdometerReset 3.1.1751.2.18.12.15.1.23
Odometer reset button.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reset(1)  

vbrAtmSpvcVccStatsCellsDroppedB 3.1.1751.2.18.12.15.1.24
Cells Dropped on the Incoming side of B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vbrAtmSpvcVccStatsCellsTaggedB 3.1.1751.2.18.12.15.1.25
Cells Tagged on the Incoming side of B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSpvcVccStatsTable 3.1.1751.2.18.12.16
Table of statistics for a ATM SPVC channel connection
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmSpvcVccStatsEntry

atmSpvcVccStatsEntry 3.1.1751.2.18.12.16.1
Row definition for the ATM SPVC connection statistics table
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmSpvcVccStatsEntry  

atmSpvcVccStatsIfA 3.1.1751.2.18.12.16.1.1
Interface index for side A of an ATM-to-ATM PVC VCC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

atmSpvcVccStatsVpiA 3.1.1751.2.18.12.16.1.2
VPI value for side A of an ATM-to-ATM PVC VCC connection. Valid range is a number between 0 and 4095.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..4095  

atmSpvcVccStatsVciA 3.1.1751.2.18.12.16.1.3
VCI value for side A of an ATM-to-ATM PVC VCC connection. Valid range is a number between 0 and 65535.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..65535  

atmSpvcVccStatsIfB 3.1.1751.2.18.12.16.1.4
Interface index for side B of an ATM-to-ATM PVC VCC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

atmSpvcVccStatsVpiB 3.1.1751.2.18.12.16.1.5
VPI value for side B of an ATM-to-ATM PVC VCC connection. Valid range is a number between 0 and 4095.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..4095  

atmSpvcVccStatsVciB 3.1.1751.2.18.12.16.1.6
VCI value for side B of an ATM-to-ATM PVC VCC connection. Valid range is a number between 0 and 65535.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..65535  

atmSpvcVccStatsInCellCountHiA 3.1.1751.2.18.12.16.1.7
Valid Cells received on A - (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSpvcVccStatsInCellCountLoA 3.1.1751.2.18.12.16.1.8
Valid Cells received on A - (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSpvcVccStatsOutCellCountHiA 3.1.1751.2.18.12.16.1.9
Valid cells transmitted on A -(High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSpvcVccStatsOutCellCountLoA 3.1.1751.2.18.12.16.1.10
Valid cells transmitted on A -(Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSpvcVccStatsInCellCountHiB 3.1.1751.2.18.12.16.1.11
Valid Cells received on B - (High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSpvcVccStatsInCellCountLoB 3.1.1751.2.18.12.16.1.12
Valid Cells received on B - (Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSpvcVccStatsOutCellCountHiB 3.1.1751.2.18.12.16.1.13
Valid cells transmitted on B -(High order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSpvcVccStatsOutCellCountLoB 3.1.1751.2.18.12.16.1.14
Valid cells transmitted on B -(Low order portion)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSpvcVccStatsTimer 3.1.1751.2.18.12.16.1.15
Number of seconds stats have been collecting
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSpvcVccStatsFrwdErrCrrctnRateA2B 3.1.1751.2.18.12.16.1.16
Displays the Forward error correction rate being used by the FEC module in the A2B direction. This field is dynamic when Auto rates are selected. In other cases, it will display the rate set by the user.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), eighthRate(2), quarterRate(3), halfRate(4)  

atmSpvcVccStatsFrwdErrCrrctnRateB2A 3.1.1751.2.18.12.16.1.17
Displays the Forward error correction rate being used by the FEC module in the B2A direction. This field is dynamic when Auto rates are selected. In other cases, it will display the rate set by the user.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), eighthRate(2), quarterRate(3), halfRate(4)  

atmSpvcVccStatsInOdometerCellCountHiA 3.1.1751.2.18.12.16.1.18
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSpvcVccStatsInOdometerCellCountLoA 3.1.1751.2.18.12.16.1.19
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSpvcVccStatsOutOdometerCellCountHiA 3.1.1751.2.18.12.16.1.20
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSpvcVccStatsOutOdometerCellCountLoA 3.1.1751.2.18.12.16.1.21
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSpvcVccStatsInOdometerCellCountHiB 3.1.1751.2.18.12.16.1.22
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSpvcVccStatsInOdometerCellCountLoB 3.1.1751.2.18.12.16.1.23
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSpvcVccStatsOutOdometerCellCountHiB 3.1.1751.2.18.12.16.1.24
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSpvcVccStatsOutOdometerCellCountLoB 3.1.1751.2.18.12.16.1.25
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSpvcVccStatsOdometerTimer 3.1.1751.2.18.12.16.1.26
Number of seconds since odometer was reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSpvcVccStatsOdometerReset 3.1.1751.2.18.12.16.1.27
Odometer reset button.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reset(1)  

atmSpvcVccStatsCellsDroppedA 3.1.1751.2.18.12.16.1.28
Cells Dropped on the Incoming side of A
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSpvcVccStatsCellsTaggedA 3.1.1751.2.18.12.16.1.29
Cells Tagged on the Incoming side of A
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSpvcVccStatsCellsDroppedB 3.1.1751.2.18.12.16.1.30
Cells Dropped on the Incoming side of B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSpvcVccStatsCellsTaggedB 3.1.1751.2.18.12.16.1.31
Cells Tagged on the Incoming side of B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAtmArpSrvConnType 3.1.1751.2.18.13.1
type of Arp Server connection
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER pvc(1), svc(2), none(3)  

ipAtmIpAddr 3.1.1751.2.18.13.2
Local IP Address
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

ipAtmIpMask 3.1.1751.2.18.13.3
Local IP Mask
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

atmArpTable 3.1.1751.2.18.13.4
ARP Table
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmArpEntry

atmArpEntry 3.1.1751.2.18.13.4.1
ARP Table entry
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmArpEntry  

atmArpIpAddress 3.1.1751.2.18.13.4.1.1
IP address of the IP host described in APR table entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  IpAddress  

atmArpAtmAddress 3.1.1751.2.18.13.4.1.2
ATM address of the IP host.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(20)  

atmArpAddrType 3.1.1751.2.18.13.4.1.3
Type of ATM address value of atmArp address.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER nsap(1), e164(2), e164nsap(3)  

atmArpEntryState 3.1.1751.2.18.13.4.1.4
State of this entry.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), unconnected(3), permanent(4), pendingAtmAddr(5), pendingIpAddr(6), pendingConnect(7)  

atmArpEntryRowStatus 3.1.1751.2.18.13.4.1.5
RowStatus of this entry.
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

appIpRouteTable 3.1.1751.2.18.13.5
Application IP Routing table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AppIpRouteEntry

appIpRouteEntry 3.1.1751.2.18.13.5.1
A route to a particular destination.
Status: current Access: not-accessible
OBJECT-TYPE    
  AppIpRouteEntry  

appIpRouteDest 3.1.1751.2.18.13.5.1.1
The destination IP address of this route. An entry with a value of 0.0.0.0 is not valid route.
Status: current Access: not-accessible
OBJECT-TYPE    
  IpAddress  

appIpRouteMask 3.1.1751.2.18.13.5.1.2
Mask for Ip route, usefull only for SENS stack VxWorks
Status: current Access: not-accessible
OBJECT-TYPE    
  IpAddress  

appIpRouteMetric1 3.1.1751.2.18.13.5.1.3
The primary routing metric for this route. The semantics of this metric are determined by the routing-protocol specified in the routes appIpRouteProto value. If this metric is not used, its value should be set to 1.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..255  

appIpRouteNextHop 3.1.1751.2.18.13.5.1.4
The IP address of the next hop of this route. (In the case of a route bound to an interface which is realized via a broadcast media, the value of this field is the agent's IP address on that interface.)
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

appIpRouteState 3.1.1751.2.18.13.5.1.5
Current state of route
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER invalid(0), inuse(1), notinuse(2), error(3)  

iispCbrRoutTable 3.1.1751.2.18.14.1
IISP CBR Routing Table
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IispCbrRoutEntry

iispCbrRoutEntry 3.1.1751.2.18.14.1.1
IISP CBR Table Entry
Status: current Access: not-accessible
OBJECT-TYPE    
  IispCbrRoutEntry  

iispCbrRoutLength 3.1.1751.2.18.14.1.1.1
length in bits
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

iispCbrRoutNsapAddr 3.1.1751.2.18.14.1.1.2
nsap address
Status: current Access: not-accessible
OBJECT-TYPE    
  OCTET STRING Size(1..20)  

iispCbrRoutIfIndex 3.1.1751.2.18.14.1.1.3
Interface index - SSPPCCC
Status: current Access: read-write
OBJECT-TYPE    
  IntfIndex  

iispCbrRoutRowStatus 3.1.1751.2.18.14.1.1.4
row status
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

iispVbrRoutTable 3.1.1751.2.18.14.2
IISP CBR Routing Table
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IispVbrRoutEntry

iispVbrRoutEntry 3.1.1751.2.18.14.2.1
IISP CBR Table Entry
Status: current Access: not-accessible
OBJECT-TYPE    
  IispVbrRoutEntry  

iispVbrRoutLength 3.1.1751.2.18.14.2.1.1
length in bits
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

iispVbrRoutNsapAddr 3.1.1751.2.18.14.2.1.2
nsap address
Status: current Access: not-accessible
OBJECT-TYPE    
  OCTET STRING Size(1..20)  

iispVbrRoutIfIndex 3.1.1751.2.18.14.2.1.3
Interface index - SSPPCCC
Status: current Access: read-write
OBJECT-TYPE    
  IntfIndex  

iispVbrRoutRowStatus 3.1.1751.2.18.14.2.1.4
row status
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

iispCbrRouteTable 3.1.1751.2.18.14.3
IISP CBR Routing Table
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IispCbrRouteEntry

iispCbrRouteEntry 3.1.1751.2.18.14.3.1
IISP CBR Route Entry
Status: current Access: not-accessible
OBJECT-TYPE    
  IispCbrRouteEntry  

iispCbrRouteLength 3.1.1751.2.18.14.3.1.1
length in bits
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

iispCbrRouteNsapAddr 3.1.1751.2.18.14.3.1.2
nsap address
Status: current Access: not-accessible
OBJECT-TYPE    
  OCTET STRING Size(1..20)  

iispCbrRouteIfIndex 3.1.1751.2.18.14.3.1.3
Interface index - SSPPCCC
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

iispCbrRouteRowStatus 3.1.1751.2.18.14.3.1.4
row status
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

iispCbrRouteIfVuniId 3.1.1751.2.18.14.3.1.5
Virtual UNI interface VUNI Id
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..255  

iispCbrRouteType 3.1.1751.2.18.14.3.1.6
Type of Route, Categorisation of an Endpoint Route or an intermediate Route
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER drmRouteTypeAny(0), drmRouteTypeAtm(1), drmRouteTypeIisp(2), drmRouteTypeIlmiUser(3), drmRouteTypeIsdn(11), drmRouteTypeCe(21), drmRouteTypeSs7(31), drmRouteTypeFr(41), drmRouteTypeCasTrunk(51), drmRouteTypeEndPtAtm(132), drmRouteTypeEndPtCe(133), drmRouteTypeEndPtTe(134), drmRouteTypeEndPtIsdn(135), drmRouteTypeEndPtIp(136), drmRouteTypeEndPtFr(137)  

iispCbrRouteDest 3.1.1751.2.18.14.3.1.7
Type of Destination, Categorisation of an Endpoint destination or an intermediate destination
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER drmRouteDestAny(0), drmRouteDestAtm(1), drmRouteDestIsdn(2), drmRouteDestCe(3), drmRouteDestSs7(4), drmRouteDestFr(5), drmRouteDestAalIwf(6), drmRouteDestEndPtAtm(15), drmRouteDestEndPtCe(16), drmRouteDestEndPtTe(17), drmRouteDestEndPtIsdn(18), drmRouteTypeEndPtIp(19), drmRouteTypeEndPtFr(20), drmRouteTypeEndPtCas(21)  

iispVbrRouteTable 3.1.1751.2.18.14.4
IISP CBR Routing Table
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IispVbrRouteEntry

iispVbrRouteEntry 3.1.1751.2.18.14.4.1
IISP CBR Table Entry
Status: current Access: not-accessible
OBJECT-TYPE    
  IispVbrRouteEntry  

iispVbrRouteLength 3.1.1751.2.18.14.4.1.1
length in bits
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

iispVbrRouteNsapAddr 3.1.1751.2.18.14.4.1.2
nsap address
Status: current Access: not-accessible
OBJECT-TYPE    
  OCTET STRING Size(1..20)  

iispVbrRouteIfIndex 3.1.1751.2.18.14.4.1.3
In most cases, it is the I/O Interface index - SSPPCCC. However, in case of ATM Trunking's Narrowband routing and Broadband routing, this is either the CAS trunk group ID, or the remote IWF ID, which are 1 to 3 digits decimal numbers
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

iispVbrRouteRowStatus 3.1.1751.2.18.14.4.1.4
row status
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

iispVbrRouteIfVuniId 3.1.1751.2.18.14.4.1.5
Virtual UNI interface VUNI Id
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..255  

iispVbrRouteType 3.1.1751.2.18.14.4.1.6
Type of Route, Categorisation of an Endpoint Route or an intermediate Route
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER drmRouteTypeAny(0), drmRouteTypeAtm(1), drmRouteTypeIisp(2), drmRouteTypeIlmiUser(3), drmRouteTypeIsdn(11), drmRouteTypeCe(21), drmRouteTypeSs7(31), drmRouteTypeFr(41), drmRouteTypeCasTrunk(51), drmRouteTypeIwfTrunk(61), drmRouteTypeEndPtAtm(132), drmRouteTypeEndPtCe(133), drmRouteTypeEndPtTe(134), drmRouteTypeEndPtIsdn(135), drmRouteTypeEndPtIp(136), drmRouteTypeEndPtFr(137)  

iispVbrRouteDest 3.1.1751.2.18.14.4.1.7
Type of Destination, Categorisation of an Endpoint destination or an intermediate destination
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER drmRouteDestAny(0), drmRouteDestAtm(1), drmRouteDestIsdn(2), drmRouteDestCe(3), drmRouteDestSs7(4), drmRouteDestFr(5), drmRouteDestAalIwf(6), drmRouteDestEndPtAny(14), drmRouteDestEndPtAtm(15), drmRouteDestEndPtCe(16), drmRouteDestEndPtTe(17), drmRouteDestEndPtIsdn(18), drmRouteTypeEndPtIp(19), drmRouteTypeEndPtFr(20), drmRouteTypeEndPtCas(21), drmRouteTypeEndPtTrkIwf(22)  

pvcFailureReasonCode 3.1.1751.2.18.15.1
An identified reason why an ATM PVC connection request failed. aal2CuTimerOutOfRange(298): this error code is generated when the aal2CuTimer value is out of range and the valid reanges is 0 to 8 (0 - 40 msec of delay). unrecognizableDigitCollectTypeA2B(299): unrecognizable digital tone set in connection A2B direction. unrecognizableDigitCollectTypeB2A(300): unrecognizable digital tone set in connection B2A direction.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER vpiVciUnavailableA2B(1), vpiVciUnavailableB2A(2), bandwidthUnavailableA2B(3), bandwidthUnavailableB2A(4), qosUnavailableA2B(5), qosUnavailableB2A(6), internalResourceUnavailable(7), cantUseSignalingChnlIgrsA2B(8), cantUseSignalingChnlEgrsA2B(9), cantUseSignalingChnlIgrsB2A(10), cantUseSignalingChnlEgrsB2A(11), cantUseManagementChnlIgrsA2B(12), cantUseManagementChnlEgrsA2B(13), cantUseManagementChnlIgrsB2A(14), cantUseManagementChnlEgrsB2A(15), vcLessThanVcMinIgrsA2B(16), vcLessThanVcMinEgrsA2B(17), vcLessThanVcMinIgrsB2A(18), vcLessThanVcMinEgrsB2A(19), vcGreaterThanVcMaxIgrsA2B(20), vcGreaterThanVcMaxEgrsA2B(21), vcGreaterThanVcMaxIgrsB2A(22), vcGreaterThanVcMaxEgrsB2A(23), vpLessThanVpMinIgrsA2B(24), vpLessThanVpMinEgrsA2B(25), vpLessThanVpMinIgrsB2A(26), vpLessThanVpMinEgrsB2A(27), vpGreaterThanVpMaxIgrsA2B(28), vpGreaterThanVpMaxEgrsA2B(29), vpGreaterThanVpMaxIgrsB2A(30), vpGreaterThanVpMaxEgrsB2A(31), vpGreaterThanVpMaxIispIgrsA2B(32), vpGreaterThanVpMaxIispEgrsA2B(33), vpGreaterThanVpMaxIispIgrsB2A(34), vpGreaterThanVpMaxIispEgrsB2A(35), rsvdChnlRangeIgrsA2B(36), rsvdChnlRangeEgrsA2B(37), rsvdChnlRangeIgrsB2A(38), rsvdChnlRangeEgrsB2A(39), internalSrvcTypeUnavailableA2B(40), internalSrvcTypeUnavailableB2A(41), unrecognizableBindTypeEgrsA2B(42), unrecognizableBindTypeEgrsB2A(43), callWithoutConnections(44), callDataStructuresUnavailable(45), cnctnDataStructuresUnavailable(46), nullTrafficParametersRejectedA2B(47), nullTrafficParametersRejectedB2A(48), vpiWithinSvcRangeIgrsA2B(49), vpiWithinSvcRangeEgrsA2B(50), vpiWithinSvcRangeIgrsB2A(51), vpiWithinSvcRangeEgrsB2A(52), vpiInReservedListA2B(53), vpiInReservedListB2A(54), vpiInPvcListA2B(55), vpiInPvcListB2A(56), vpiInReleasedListA2B(57), vpiInReleasedListB2A(58), vciIsNotNullInVpcIgrsA2B(59), vciIsNotNullInVpcEgrsA2B(60), vciIsNotNullInVpcIgrsB2A(61), vciIsNotNullInVpcEgrsB2A(62), vpiInVpcReservedListA2B(63), vpiInVpcReservedListB2A(64), vpiVciInReservedListA2B(65), vpiVciInReservedListB2A(66), vpiInVpcPvcListA2B(67), vpiInVpcPvcListB2A(68), vpiVciInPvcListA2B(69), vpiVciInPvcListB2A(70), vpiInVpcReleasedListA2B(71), vpiInVpcReleasedListB2A(72), vpiVciInReleasedListA2B(73), vpiVciInReleasedListB2A(74), illegalMulticaseIdA2B(75), illegalMulticaseIdB2A(76), unsupportedConnectionA2B(77), unsupportedConnectionB2A(78), connectionsUnavailableInModuleA2B(79), connectionsUnavailableInModuleB2A(80), cbrBandwidthUnavailableIgrsA2B(81), cbrBandwidthUnavailableEgrsA2B(82), cbrBandwidthUnavailableIgrsB2A(83), cbrBandwidthUnavailableEgrsB2A(84), vbrBandwidthUnavailableIgrsA2B(85), vbrBandwidthUnavailableEgrsA2B(86), vbrBandwidthUnavailableIgrsB2A(87), vbrBandwidthUnavailableEgrsB2A(88), vpiVciWithinSvcRangeIgrsA2B(89), vpiVciWithinSvcRangeEgrsA2B(90), vpiVciWithinSvcRangeIgrsB2A(91), vpiVciWithinSvcRangeEgrsB2A(92), multicastDataStructuresUnavailable(93), semaphoreTimeout(94), dlciFoundInReservedList(95), dlciFoundInPvcList(96), dlciFoundInReleasedList(97), invalidDlci(98), slotA-OutOfRange(99), portA-OutOfRange(100), channelA-OutOfRange(101), moduleA-Uninitialized(102), physicalPortA-Uninitialized(103), channelA-NotBound(104), moduleA-UnrecognizablePortType(105), slotB-OutOfRange(106), portB-OutOfRange(107), channelB-OutOfRange(108), moduleB-Uninitialized(109), physicalPortB-Uninitialized(110), channelB-NotBound(111), moduleB-UnrecognizablePortType(112), interfaceA-NotAtm(113), interfaceB-NotAtm(114), unrecognizableServiceTypeA2B(115), unrecognizableServiceTypeB2A(116), unrecognizableSarTypeA2B(117), unrecognizableSarTypeB2A(118), interfaceA-NotCircuitEmulation(119), interfaceB-NotCircuitEmulation(120), unrecognizableSilenceDetectionMode(121), unrecognizableEchoCancellationMode(122), unrecognizableVoiceCompressionMode(123), interfaceA-NotVbr(124), interfaceB-NotVbr(125), interfaceA-NotFrameRelay(126), interfaceB-NotFrameRelay(127), interfaceA-InHdlcPvcList(128), interfaceA-InHdlcReleasedList(129), interfaceA-InHdlcReservedList(130), interfaceA-InTerminalEmulationPvcList(131), interfaceA-InTerminalEmulationReleasedList(132), interfaceA-InTerminalEmulationReservedList(133), interfaceA-InCircuitEmulationPvcList(134), interfaceA-InCircuitEmulationReleasedList(135), interfaceA-InCircuitEmulationReservedList(136), notNullVpcInNoisyLinkA2BIgrs(137), notNullVpcInNoisyLinkA2BEgrs(138), invalidVccInNoisyLinkA2BIgrs(139), invalidVccInNoisyLinkA2BEgrs(140), unsupportedFrwdErrCorrectValueA2B(141), interfaceB-InHdlcPvcList(142), interfaceB-InHdlcReleasedList(143), interfaceB-InHdlcReservedList(144), interfaceB-InTerminalEmulationPvcList(145), interfaceB-InTerminalEmulationReleasedList(146), interfaceB-InTerminalEmulationReservedList(147), interfaceB-InCircuitEmulationPvcList(148), interfaceB-InCircuitEmulationReleasedList(149), interfaceB-InCircuitEmulationReservedList(150), notNullVpcInNoisyLinkB2AIgrs(151), notNullVpcInNoisyLinkB2AEgrs(152), invalidVccInNoisyLinkB2AIgrs(153), invalidVccInNoisyLinkB2AEgrs(154), unsupportedFrwdErrCorrectValueB2A(155), interfaceInUse(156), unsupportedFrwdErrCorrectSettings(157), unsupportedFlowSettings(158), frwdErrCorrectResourceInternalError(159), unsupportedConnection(160), ipDestAddrSubnetAInReservedList(161), ipDestAddrSubnetAInPvcList(162), ipDestAddrSubnetAInReleasedList(163), ipDestAddrSubnetBInReservedList(164), ipDestAddrSubnetBInPvcList(165), ipDestAddrSubnetBInReleasedList(166), notCpuIpInterfaceA(167), ipResourceUnavailable(168), fecAutoInSimplexNotValid(169), fecResourceUnavailable(170), notBridgeInterfaceA(171), notBridgeInterfaceB(172), invalidBridgePortA2B(173), invalidBridgePortB2A(174), interfaceAInBridgePvcList(175), interfaceBInBridgePvcList(176), interfaceAInBridgeReleasedList(177), interfaceBInBridgeReleasedList(178), interfaceAInBridgeReservedList(179), interfaceBInBridgeReservedList(180), invalidDlciA(181), invalidDlciB(182), unrecognizableServiceType(183), moduleAMcstNotSupported(184), moduleBMcstNotSupported(185), moduleAMultiPortMcstNotSupported(186), moduleBMultiPortMcstNotSupported(187), bcBeCirCannotBeNullA2B(188), bcBeCirCannotBeNullB2A(189), bcBeOrCirValTooHiA2B(190), bcBeOrCirValTooHiB2A(191), bcNotValidA2B(192), bcNotValidB2A(193), beNotValidA2B(194), beNotValidB2A(195), bcOrCirNotValidA2B(196), bcOrCirNotValidB2A(197), iWF-NotSupportedModuleA(198), iWF-NotSupportedModuleB(199), invalidMaxFrSizeA2B(200), invalidMaxFrSizeB2A(201), invalidSARType(202), unrecognizableSilenceDetectionModeA2B(203), unrecognizableEchoCancellationModeA2B(204), unrecognizableVoiceCompressionModeA2B(205), unrecognizableCallingToneDetectionA2B(206), unrecognizableCodingTranslationA2B(207), unrecognizableSilenceDetectionModeB2A(208), unrecognizableEchoCancellationModeB2A(209), unrecognizableVoiceCompressionModeB2A(210), unrecognizableCallingToneDetectionB2A(211), unrecognizableCodingTranslationB2A(212), dspUnsupportedForMultiCastConns(213), dspResourceUnavailable(214), destOrSrcCannotBeDSPCard(215), internalDSPResourceError(216), echoCancellationOnlySupportedForDuplex(217), cirEmCirEm-ThruPutMismatch(218), vi-Cannot-Be-0(219), vi-OOR(220), vi-Mod-Limit-Exceeded(221), vi-Resource-Unavail(222), vi-Already-Exists(223), vi-Does-Not-Exist(224), vi-0-Non-Ubr-Conn-Not-Supp(225), vi-OS-Cannot-Be-0(226), vi-OS-OOR(227), vi-CellRate-Too-Lo(228), vi-CellRate-Too-Hi(229), intf-CBR-CellRate-Exceeded(230), intf-VBR-CellRate-Exceeded(231), vi-Conn-CellRate-Exceeded(232), vi-Not-Enabled(233), vi-Should-Be-0(234), vi-OOR-A(235), vi-OOR-B(236), vi-0-Non-Ubr-Conn-Not-SuppA2B(237), vi-0-Non-Ubr-Conn-Not-SuppB2A(238), vi-Should-Be-0-A(239), vi-Should-Be-0-B(240), vi-Cbr-Bw-Unavailable-Egrs(241), vi-Cbr-Bw-Unavailable-Egrs-A(242), vi-Cbr-Bw-Unavailable-Egrs-B(243), vi-Vbr-Bw-Unavailable-Egrs(244), vi-Vbr-Bw-Unavailable-Egrs-A(245), vi-Vbr-Bw-Unavailable-Egrs-B(246), vi-Not-Enabled-A(247), vi-Not-Enabled-B(248), pcrLessThanScr(249), cnfrmTypeNotValidA2B(250), cnfrmTypeNotValidB2A(251), cnfrmType-ServiceType-Mismatch-A2B(252), cnfrmType-ServiceType-Mismatch-B2A(253), vuni-Should-Be-0(254), vuni-Not-Enabled(255), vuni-OOR(256), vuni-Already-Exists(257), vuni-Does-Not-Exist(258), vuni-Does-Not-Match-vi(259), vuni-Should-Be-0-A(260), vuni-Not-Enabled-A(261), vuni-OOR-A(262), vuni-Already-Exists-A(263), vuni-Does-Not-Exist-A(264), vuni-Does-Not-Match-vi-A(265), vuni-Should-Be-0-B(266), vuni-Not-Enabled-B(267), vuni-OOR-B(268), vuni-Already-Exists-B(269), vuni-Does-Not-Exist-B(270), vuni-Does-Not-Match-vi-B(271), vuni-Vpi-OOR(272), vuni-Vpi-OOR-A(273), vuni-Vpi-OOR-B(274), stdAal2TrunkResourceUnavailable(275), stdAal2Dsp2ResourceUnavailable(276), slotStdAal2ResourceUavailable(277), stdAal2CIDAlreadyInUse(278), stdAal2TrunkBWUavailableEgrs(279), stdAal2TrunkBWUavailableIgrs(280), stdAal2CIDInRsvRange(281), stdAal2TrunkNotSetup(282), aal2CIDOutOfRange(283), dhpvcSwitchOver-PrimToBkup(284), dhpvcSwitchOver-PrimToNone(285), dhpvcSwitchOver-NoneToPrim(286), dhpvcSwitchOver-NoneToBkup(287), dhpvcSwitchOver-BkupToNone(288), dhpvcSwitchOver-BkupToPrim(289), dhpvcState-Prim-Pass-Fail-Bkup-Act-NoFail(290), dhpvcState-Prim-Pass-NoFail-Bkup-Act-NoFail(291), dhpvcState-Prim-Act-NoFail-Bkup-Pass-Fail(292), dhpvcState-Prim-Act-NoFail-Bkup-Pass-NoFail(293), pcrGreaterThanLinkSpeedIngrA2B(294), pcrGreaterThanLinkSpeedIngrB2A(295), pcrGreaterThanLinkSpeedEgrA2B(296), pcrGreaterThanLinkSpeedEgrB2A(297), aal2CuTimerOutOfRange(298), unrecognizableDigitCollectTypeA2B(299), unrecognizableDigitCollectTypeB2A(300), queueTypeSarTypeMismatchA2B(301), queueTypeSarTypeMismatchB2A(302), pcrLessThanOrEqualToMcrA2B(303), pcrLessThanOrEqualToMcrB2A(304)  

interfaceIndex 3.1.1751.2.18.15.2
Interface index used for identifcation in traps. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: read-only
OBJECT-TYPE    
  IntfIndex  

interfaceType 3.1.1751.2.18.15.3
Interface type used for identification in traps. A specific interface is associated with each number. atmUni3-0(1) ATM User Network Interface version 3.0 atmUni3-1(2) ATM User Network Interface version 3.1 iispUser(3) Interim Inter Switch Protocol User Side iispNetwork(4) Interim Inter Switch Protocol Network Side circuitEmulation(5) ATM Circuit Emulation frameRelayUni(6) Frame Relay User Network Interface pri-isdn-user(7) Integrated Services Digital Network Primary Rate Interface User Interface pri-isdn-network(8) Integrated Services Digital Network Primary Rate Interface Network Interface terminalEmulation(9) Terminal Emulation dsp(10) DSP hdlcPassThrough(11) High Level Data Link Control Pass Through Interface bridge(12) Ethernet Bridge routing(13) Ethernet Routing dbCirEm(14) Dynamic Bandwidth Circuit Emulation frameRelayNni(15) Frame Relay Network Network Interface dsp2(16) DSP2 atmIma(17) ATM Inverse Multiplexing over ATM (IMA) atmPnni1-0(18) ATM Private Network Network Interface Version 1.0 atmUni4-0(19) ATM User Network Interface Version 4.0 atmVnnUni3-1(20) ATM Virtual Network Navigator User Network Interface Version 3.1 casTrunkLine(21) Channel Associated Signaling Trunk Line Interface toneAnnce(22) Tone Announcement Interface gr303(23) GR303
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER atmUni3-0(1), atmUni3-1(2), iispUser(3), iispNetwork(4), circuitEmulation(5), frameRelayUni(6), pri-isdn-user(7), pri-isdn-network(8), terminalEmulation(9), dsp(10), hdlcPassThrough(11), bridge(12), routing(13), dbCirEm(14), frameRelayNni(15), dsp2(16), atmIma(17), atmPnni1-0(18), atmUni4-0(19), atmVnnUni3-1(20), casTrunkLine(21), toneAnnce(22), gr303(23)  

interfaceFailureReasonCode 3.1.1751.2.18.15.4
Identification of cause for failure in changing the status of an interface. interfaceInService(1) Most, if not all, modifications require that the interface be out of service. interfaceNotNew(2) Some modifications require that the interface must never have been in service. interfaceExists(3) Some modifications, such as setting the interface type, require that no interface exists. (type must be unconfigured). bridgeGroupActive(4) For setting the bridgeDomainNumber in bridge or router interfaces. to add an interface to a bridgeGroup, the bridgeGroup must be in service. signalingNotEnabled(5) For this interface to be created, signaling must be enabled. firmwareOutOfDate(6) The firmware for the i/o card does not work with this interface. t1SigEnableInterfaceNotSupported(7) The interface is not supported if T1 signaling is enabled ts16ForData(8) ts16 has been set for passing data and the user attempts to turn on signaling. dbcesConfigured(9) Signaling cannot be disabled because this interface is configured as dbces. signalingEnabled(10) Signaling is on for at least one of the channels while trying to change e1 TS16 from CAS to CCS. cmCardTypeNotSupported(11) CM_NET interface is only supported by DS3 DS1 OC3 and SUPER_DS1 cards cmMultipleIntfNotSupported(12) only one interface can be configured as CM_NET cmIntfInService(13) CM_NET interface is in-service cmInterfaceConfigured(14) CM_NET interface is configured channelizationEnabled(15) A port can not be channelized in order to support unstructured CE. unstructuredCEConfigured(16) A port which has been channelized can not be configured to support unstructured CE. firmwareOutOfDate-ts16CAS-unsupported(17) ts16CAS is not supported by the firmware firmwareOutOfDate-interfaceType-unsupported(18) interface type is not supported by the firmware firmwareOutOfDate-ts16-unsupported(19) ts16 is not supported by the firmware invalidPortMap(20) invalid port map otherInterfacesExistOnThisPort(21) ISDN interface needs all 24 channels on the port. If any of the channels on that interface are already configured, the ISDN interface can not be defined on that port. intfInIMAgroup(22) chanId bit in portMap is 1 errorCTC-portTxClkSrc-notLocal(23) if imaGrpChannelNeTxClkMode is set to ctc then all ports should have the transmitClockSource as localTiming different-LoopbackConfig-on-Ports(24) all physical ports included in the portMap must have the same loopback configuration imaGChanNeTxClkMode-unsupported(25) ima group channel near-end Tx clock mode is not supported intfChange-Disallowed-on-APS-ProtectionPort(26) an interface cannot be manipulated via protection port in an APS setup intferfaceCurrentlyNotSupported(27) the interface type is not support currently failure-at-call-handler(28) interface creation failure due to call handler unstructuredCE-payloadloop(29) Unstructured CE should not have payload loopback as a loop back option channelConfigModeNotConforming(30) There was a limitation on the channel mode of DSP_2D card: if there is a channel is already inService, all the channel mode of configured channels must be the same as that of the channel inService; all the channel mode of unconfigured channels can only be configured the same as that of the channel inService. usageOfReservedTimeSlot(31) for HD_E1, do not allow any configuration to be SET on channel number 1 or 17 (base 1) or chan 0 or 16 (base 0). virtualIntf-and-AtmSignaling-bothCannotBeEnabled(32) vitual interface and signalling cannot both be enabled at the same time virtualUni-and-AtmSignaling-bothCannotBeEnabled(33) vitual UNI and signalling cannot both be enabled at the same time virtualUni-notSupported(34) virtual UNI is not supported atmUni-UbrLoadBalSupp-cannotBeEnabled-whenSignalingDisabled(35) ubr load balancing cannot be enabled when signaling is disabled virtualInterface-notSupported(36) virtual interface support only allowed on APS type of cards card-doesNotSupport-UPC(37) only some cardTypes support UPC atmUni-SvcVpiVci-RangeCheck-Failure(38) Do range check provided atmSignaling is enabled vciMinSvc <= vciMaxSvc and vpiMinSvc <= vpiMaxSvc atmUni-SigVpiVci-Within-Svc-Range(39) atmUni{Vpi,Vci}Sig should not be within svc range atmUni-Ilmi-Svc-Sig-VpiVci-Clash(40) if IlmiProtocol status and atmUniSignaling are both enabled then the Ilmi Vpi/Vci should not fall in the Svc range and should not be equal to signaling vpi/vci virtualUNI-VpiNotAvailable(41) vpi is not available for the virtual UNI virtualUNI-InvalidVUNIId(42) vitural UNI Index is invalid intfNotSupported-with-ds1LineType-d4(43) if dsx1LineType is DSX1_D4 channel, interface type can't be atmIma intfNotSupported-with-ds1LineCoding-ami(44) if dsx1LineCoding is DSX1_AMI channel interface type can't be atmIma onlyCEsupported-with-msBitStuffing-enabled(45) if msBitStuffing is enabled only interface type circuit emulation is supported vISuppConnTrafficShapingMutuallyExclusive(46) The VI support flag and Traffic Shaping flag are mutually exclusive tS16onPortNotCAS(47) must have cas on port for channel to have cas trunk line interface channelizationDisabled(48) should have channelization enabled to have cas trunk line primaryDS1InterfaceNotConfigured(49) primary DS1 interface is not configured primaryTMCChanNotConfigured(50) primary timeslot management channel is not configured primaryTMCIntfAlreadyConfiguredInAnotherIg(51) primary timeslot management channel interface is already configured in another interface group primaryTMCIntfCantBeChanged(52) primary timeslot management channel interfance can't be changed primaryEOCChanNotConfigured(53) primary embeded operation channel is not configured primaryEOCIntfAlreadyConfiguredInAnotherIg(54) primary embeded operation channel interface is already configured in another interface group primaryTMC-EOCIntfShouldBeSame(55) primary timeslot management channel and embeded operation channel interfaces should be the same primaryEOCIntfCantBeChanged(56) primary embeded operation channel inteface can't be changed primaryTMC-BackupTMCIntfCantBeSame(57) primary and backup timeslot management channel interfaces can't be the same backupDS1InterfaceNotConfigured(58) backup DS1 interface is not configured backupTMCChanNotConfigured(59) backup timeslot management channel is not configured backupTMCIntfAlreadyConfiguredInAnotherIg(60) backup timeslot management channel interface is already configured in another interface group backupTMCIntfCantBeChanged(61) backup timeslot management channel interfance can't be changed primaryEOC-BackupEOCIntfCantBeSame(62) primary and backup embeded operation channel interfaces can't be the same backupEOCChanNotConfigured(63) backup embeded operation channel is not configured backupEOCIntfAlreadyConfiguredInAnotherIg(64) backup embeded operation channel interface is already configured in another interface group backupTMC-EOCIntfShouldBeSame(65) backup timeslot management channel and embeded operation channel interfaces should be the same backupEOCIntfCantBeChanged(66) backup embeded operation channel inteface can't be changed newBWBelowCurrentAllocated(67) new bandwidth is below the current allocated bandwidth newBWBelowCurrentAllocated-SvcsBeingDeleted(68) new bandwidth is below the current allocated bandwidth svc is being deleted newBWBelowCurrentAllocated-DeletePvcs(69) new bandwidth is below the current allocated bandwidth delete pvc newBWAboveCurrentAllocated(70) new bandwidth is above the current allocated bandwidth primaryInactive-or-SecondaryActive-In-IntfProtTable(71) an interface can't be deleted if it is in interface protection group which is primary/inactive or secondry/active onlyCEsupported-with-msLOSDetection-enabled(72) if msLOSDetection is enabled, only interface type circuit emulation is supported nonMuxNotAllowed-with-FaxRelay(73) DSP2 cards: if channelMode is CFG_DSP2_FAX_RELAY, aalMode can't be D_dsp2AalMode_aal2_non_multiplexed, invalid-DSPmode-and-AALmode-combination(74) DSP2 cards: such DSP mode and AAL mode combination is not allowed noBandwidth-For-SignalingConns(75) no bandwidth for signal connections
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER interfaceInService(1), interfaceNotNew(2), interfaceExists(3), bridgeGroupActive(4), signalingNotEnabled(5), firmwareOutOfDate(6), t1SigEnableInterfaceNotSupported(7), ts16ForData(8), dbcesConfigured(9), signalingEnabled(10), channelizationEnabled(15), unstructuredCEConfigured(16), firmwareOutOfDate-ts16CAS-unsupported(17), firmwareOutOfDate-interfaceType-unsupported(18), firmwareOutOfDate-ts16-unsupported(19), invalidPortMap(20), otherInterfacesExistOnThisPort(21), intfInIMAgroup(22), errorCTC-portTxClkSrc-notLocal(23), different-LoopbackConfig-on-Ports(24), imaGChanNeTxClkMode-unsupported(25), intfChange-Disallowed-on-APS-ProtectionPort(26), intferfaceCurrentlyNotSupported(27), failure-at-call-handler(28), unstructuredCE-payloadloop(29), channelConfigModeNotConforming(30), usageOfReservedTimeSlot(31), virtualIntf-and-AtmSignaling-bothCannotBeEnabled(32), virtualUni-and-AtmSignaling-bothCannotBeEnabled(33), virtualUni-notSupported(34), atmUni-UbrLoadBalSupp-cannotBeEnabled-whenSignalingDisabled(35), virtualInterface-notSupported(36), card-doesNotSupport-UPC(37), atmUni-SvcVpiVci-RangeCheck-Failure(38), atmUni-SigVpiVci-Within-Svc-Range(39), atmUni-Ilmi-Svc-Sig-VpiVci-Clash(40), virtualUNI-VpiNotAvailable(41), virtualUNI-InvalidVUNIId(42), intfNotSupported-with-ds1LineType-d4(43), intfNotSupported-with-ds1LineCoding-ami(44), onlyCEsupported-with-msBitStuffing-enabled(45), vISuppConnTrafficShapingMutuallyExclusive(46), tS16onPortNotCAS(47), channelizationDisabled(48), primaryDS1InterfaceNotConfigured(49), primaryTMCChanNotConfigured(50), primaryTMCIntfAlreadyConfiguredInAnotherIg(51), primaryTMCIntfCantBeChanged(52), primaryEOCChanNotConfigured(53), primaryEOCIntfAlreadyConfiguredInAnotherIg(54), primaryTMC-EOCIntfShouldBeSame(55), primaryEOCIntfCantBeChanged(56), primaryTMC-BackupTMCIntfCantBeSame(57), backupDS1InterfaceNotConfigured(58), backupTMCChanNotConfigured(59), backupTMCIntfAlreadyConfiguredInAnotherIg(60), backupTMCIntfCantBeChanged(61), primaryEOC-BackupEOCIntfCantBeSame(62), backupEOCChanNotConfigured(63), backupEOCIntfAlreadyConfiguredInAnotherIg(64), backupTMC-EOCIntfShouldBeSame(65), backupEOCIntfCantBeChanged(66), newBWBelowCurrentAllocated(67), newBWBelowCurrentAllocated-SvcsBeingDeleted(68), newBWBelowCurrentAllocated-DeletePvcs(69), newBWAboveCurrentAllocated(70), primaryInactive-or-SecondaryActive-In-IntfProtTable(71), onlyCEsupported-with-msLOSDetection-enabled(72), nonMuxNotAllowed-with-FaxRelay(73), invalid-DSPmode-and-AALmode-combination(74), noBandwidth-For-SignalingConns(75)  

powerSupplyReasonCode 3.1.1751.2.18.15.5
Identification for change in status of a power supply. overload(1) overload overloadCleared(2) overload cleared plus5vFailed(3) +5V power supply failed plus5vCleared(4) +5V power supply cleared plus120vFailed(5) +120V power supply failed plus120vCleared(6) +120V power supply cleared minus48vFailed(7) -48V power supply failed minus48vCleared(8) -48V power supply failed
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER overload(1), overloadCleared(2), plus5vFailed(3), plus5vCleared(4), plus120vFailed(5), plus120vCleared(6), minus48vFailed(7), minus48vCleared(8)  

portId 3.1.1751.2.18.15.6
Port ID used for identification in traps. Number value is interpreted as a port of the form, SSPP, where SS is the card slot and PP is the port number.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

lineStatus 3.1.1751.2.18.15.7
Bit map of the status of a line connected to a port.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

firmwareDownloadReasonCode 3.1.1751.2.18.15.8
The suspected reasons of why a firmware download would fail.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER cardInService(1), errorInFile(2), otherFailure(3), wrongCardSubType(4), driverUnavailable(5), driverInvalidHeaderChecksum(6), driverInvalidRecordChecksum(7), requestReplyTimeout(8), completeReplyTimeout(9), mapFileCorrupted(10), mapFileUnavailable(11), mapFileInvalidChecksum(12), mapFileNameImproper(13), cfgFileCorrupted(14), cfgFileUnavailable(15), cfgFileInvalidChecksum(16), wrongCardType(17), removeCardBeforeFinish(18), ioUnsupported(19)  

remoteRebootReasonCode 3.1.1751.2.18.15.9
The result of a remote reboot request.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ioCard1Reboot-OK(1), ioCard2Reboot-OK(2), ioCard3Reboot-OK(3), ioCard4Reboot-OK(4), ioCard5Reboot-OK(5), ioCard6Reboot-OK(6), ioCard7Reboot-OK(7), ioCard8Reboot-OK(8), ioCard9Reboot-OK(9), ioCard10Reboot-OK(10), ioCard11Reboot-OK(11), ioCard12Reboot-OK(12), ioCard13Reboot-OK(13), ioCard14Reboot-OK(14), ioCard15Reboot-OK(15), ioCard16Reboot-OK(16), ioCard1Reboot-NoCardInSlot(17), ioCard2Reboot-NoCardInSlot(18), ioCard3Reboot-NoCardInSlot(19), ioCard4Reboot-NoCardInSlot(20), ioCard5Reboot-NoCardInSlot(21), ioCard6Reboot-NoCardInSlot(22), ioCard7Reboot-NoCardInSlot(23), ioCard8Reboot-NoCardInSlot(24), ioCard9Reboot-NoCardInSlot(25), ioCard10Reboot-NoCardInSlot(26), ioCard11Reboot-NoCardInSlot(27), ioCard12Reboot-NoCardInSlot(28), ioCard13Reboot-NoCardInSlot(29), ioCard14Reboot-NoCardInSlot(30), ioCard15Reboot-NoCardInSlot(31), ioCard16Reboot-NoCardInSlot(32), allIOCardReboot-OK(33), allIOCardReboot-NoIOCards(34), chassisReboot-Proceeding(35), backupCpuReboot-Proceeding(36), backupCpuReboot-NoBackup(37), primaryCpuReboot-Proceeding(38), primaryCpuSwitchover-Proceeding(39), primaryCpuSwitchover-NoBackup(40), chassisReboot-Fail-VersionControlInProgress(41), backupCpuReboot-Fail-VersionControlInProgress(42), primaryCpuReboot-Fail-VersionControlInProgress(43), primaryCpuSwitchover-Fail-VersionControlInProgress(44), primaryCpuSwitchover-Fail-BkCPUDataBaseNotNew(45), primaryCpuSwitchover-Fail-BkCPUBuildNotGood(46), primaryCpuSwitchover-Fail-BkCPU-NotReady(47)  

saveConfigurationReasonCode 3.1.1751.2.18.15.10
The result of a save configuration request. equipment-OK(1) - Save of equipment configuration completed. equipment-Fail-VersionControlInProgress(2) - Save of equipment configuration failed due to ongoing version control operation. equipment-Fail(3) - Save of equipment configuration failed. connections-OK(4) - Save of connection configuration completed. connections-Fail-VersionControlInProgress(5) - - Save of connection configuration failed due to ongoing version control operation. connections-Fail(6) - Save of connection configuration failed. routing-OK(7) - Save of routing configuration completed. routing-Fail-VersionControlInProgress(8) - - Save of routing configuration failed due to ongoing version control operation. routing-Fail(9) - Save of routing configuration failed. all-OK(10) - Saving of all configurations completed. all-Fail-VersionControlInProgress(11) - - Saving of all configurations failed due to ongoing version control operation. all-Fail(12) - Saving of all configurations failed. fileTransferFailed(13) - Saving of configurations to secondary CPU failed. fileTransferCompleted(14) - Saving of configurations to secondary CPU completed. unSupportedOption(15) - Unsupported save option received. fail-backupCpuInitializationInProgress(16) - - Save operation failed due to ongoing secondary cpu initialization. expect2ndCPURebootAfterSave(17) - - Notification to expect reboot of secondary CPU after a save operation. expect2ndCPUCardFailedOrRemoved(18) - Notification to expect trap indicating removal/failure of secondary CPU after a save operation.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER equipment-OK(1), equipment-Fail-VersionControlInProgress(2), equipment-Fail(3), connections-OK(4), connections-Fail-VersionControlInProgress(5), connections-Fail(6), routing-OK(7), routing-Fail-VersionControlInProgress(8), routing-Fail(9), all-OK(10), all-Fail-VersionControlInProgress(11), all-Fail(12), fileTransferFailed(13), fileTransferCompleted(14), unSupportedOption(15), fail-backupCpuInitializationInProgress(16), expect2ndCPURebootAfterSave(17), expect2ndCPUCardFailedOrRemoved(18)  

versionConfigurationReasonCode 3.1.1751.2.18.15.11
Indicated status and results of version changing. upgrade-Start(1) upgrade starts upgrade-Completed(2) upgrade completed upgrade-Fail(3) upgrade failed downgrade-Start(4) downgrade starts downgrade-Completed(5) downgrade completed downgrade-Fail(6) downgrade failed upgrade-Fail-NoVersion(7) upgrade failed, no version upgrade-Fail-VersionControlInProgress(8) upgrade failed, version control is in progress downgrade-Fail-NoVersion(9) downgrade failed, no version downgrade-Fail-VersionControlInProgress(10) downgrade failed, version control is in progress upgrade-InProgress(11) upgrade is in progress downgrade-InProgress(12)downgrade is in progress upgrade-sanityCheck-InProgress(13) upgrade sanity check is in progress downgrade-sanityCheck-InProgress(14) downgrade sanity check is in progress upgrade-sanityCheck-Completed(15), upgrade sanity check is completed downgrade-sanityCheck-Completed(16), downgrade sanity check is completed upgrade-Fail-SanityCheckFail(17) upgrade failed due to sanity check failure downgrade-Fail-SanityCheckFail(18) downgrade failed due to sanity check failure upgrade-Fail-BkCPUFailedToRespond(19) upgrade failed since backup CPU failed to respond downgrade-Fail-BkCPUFailedToRespond(20) downgrade failed since backup CPU failed to respond upgrade-Fail-UserAbort(21) upgrade failed since user aborted downgrade-Fail-UserAbort(22) downgrade failed since user aborted synch-Start(23) synchronization starts synch-InProgress(24) synchronization is in progress synch-Completed(25) synchronization is completed synch-Fail(26) synchronization failed synch-Fail-NoBkCPU(27) synchronization failed since no backup CPU synch-Fail-SameVersion(28) synchronization failed due to the same version synch-Fail-FileCRCFailed(29) synchronization failed due to file CRC failure synch-Fail-VersionControlInProgress(30) synchronization failed since version control is in progress synch-Fail-UserAbort(31) synchronization failed since user aborted synch-Fail-SanityCheckFail(32) synchronization failed due to sanity check failure synch-Fail-BkCPUFailedToRespond(33) synchronization failed since backup CPU failed to respond synch-sanityCheck-InProgress(34) synchronization sanity check is in progress synch-sanityCheck-Completed(35) synchronization sanity check is completed failedToAbort(36) failed to abort
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER upgrade-Start(1), upgrade-Completed(2), upgrade-Fail(3), downgrade-Start(4), downgrade-Completed(5), downgrade-Fail(6), upgrade-Fail-NoVersion(7), upgrade-Fail-VersionControlInProgress(8), downgrade-Fail-NoVersion(9), downgrade-Fail-VersionControlInProgress(10), upgrade-InProgress(11), downgrade-InProgress(12), upgrade-sanityCheck-InProgress(13), downgrade-sanityCheck-InProgress(14), upgrade-sanityCheck-Completed(15), downgrade-sanityCheck-Completed(16), upgrade-Fail-SanityCheckFail(17), downgrade-Fail-SanityCheckFail(18), upgrade-Fail-BkCPUFailedToRespond(19), downgrade-Fail-BkCPUFailedToRespond(20), upgrade-Fail-UserAbort(21), downgrade-Fail-UserAbort(22), synch-Start(23), synch-InProgress(24), synch-Completed(25), synch-Fail(26), synch-Fail-NoBkCPU(27), synch-Fail-SameVersion(28), synch-Fail-FileCRCFailed(29), synch-Fail-VersionControlInProgress(30), synch-Fail-UserAbort(31), synch-Fail-SanityCheckFail(32), synch-Fail-BkCPUFailedToRespond(33), synch-sanityCheck-InProgress(34), synch-sanityCheck-Completed(35), failedToAbort(36)  

percentComplete 3.1.1751.2.18.15.12
Used for trap fileTransferStatusNotify and value equals the percent of the upgrade, downgrade, or ftp download completed.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipTypeReasonCode 3.1.1751.2.18.15.13
Indicator of which ip address had the problem.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER siteEtherIpAddr(1), siteEtherIpMask(2), siteGatewayAddr(3), siteRemoteMgrAddr1(4), siteRemoteMgrAddr2(5), siteRemoteMgrAddr3(6), siteRemoteMgrAddr4(7), siteRemoteMgrAddr5(8), inBandPrimaryIpAddress(9), inBandPrimaryIpMask(10), inBandBackupIpAddress(11), inBandBackupIpMask(12), siteIncorrectGatewaySubnet(13), siteGatewayInbandAddrMatch(14), siteIncorrectInbandSubnet(15), siteIncorrectEthernetSubnet(16), cpuIpSameAsSwitchIpAddr(17), cpuIpAddrInvalid(18), cpuAndIpMaskInvalid(19), switchAndCpuIpSubnetMismatch(20), switchIpAddrInvalid(21), switchAndIpMaskInvalid(22), cpuIpMaskClashWithInbandSubnet(23), switchIpMaskClashWithInbandSubnet(24), siteGatewayAddrInvalid(25), siteGatewayInbandAddrClash(26), unableToApplyGatewayIpAddr(27), unableToSetCpuIpInEPROM(28), unableToApplyCpuIpAddr(29), unableToApplySwitchIpAddr(30), unableToRevertBackToCpuIpAddr(31), gatewayAndCpuIpSubnetMismatch(32)  

timingReasonCode 3.1.1751.2.18.15.14
Indicator of type of relationship violated.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER invalidForwardDelay-MaxAge(1), invalidHelloTime-MaxAge(2)  

alarmCardReasonCode 3.1.1751.2.18.15.15
Configuration status of the alarm inputs and outputs. cutoff - alarm turned off. There are two ways to turn off the audible alarm, locally via the pushbutton switch on the alarm module, and remotely, via the remote alarm cutoff, one of the alarm card inputs.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER inputContactClosed(1), inputContactOpen(2), outputActivated(3), outputDactivated(4), audibleLocalAlarmEnable(5), audibleLocalAlarmCutoff(6), audibleRemoteAlarmEnable(7), audibleRemoteAlarmCutoff(8)  

removeConfigFiles 3.1.1751.2.18.15.16
Used to indicate the status of a remove configuration files request. from-PrimaryCPU(1) configuration files are removed from primary CPU from-BackupCPU(2) configuration files are removed from backup CPU chassisReboot(3) chassis reboot being done after removing configuration files failed-VersionControlInProgress(4) configuration file removal failed due to ongoing version conflict
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER from-PrimaryCPU(1), from-BackupCPU(2), chassisReboot(3), failed-VersionControlInProgress(4)  

spvcConfigFailureCode 3.1.1751.2.18.15.17
An identified reason for failure while configuring/modifying SPVC parameters. noSpvcConfigured(1) : There endpoint has not been configured as SPVC, so SPVC parameters cannot be modified. spvcAlreadyConfigured(2) : SPVC is already configured so it cannot be configured again as SPVC endpoint. noInterfaceConfigured(3) : There is no interface configured on the particular SSPPCCC. interfaceNotConfiguredAsRequired(4) : While configuring an SPVC endpoint, the interface is not as desired (e.g.it is not CE, while trying to configure CES SPVC). notActiveSpvc(6) : If the endpoint is configured with flowType ptToMptA2B the connType has to be activeSvc. slotA-OutofRange(7) : A-side of SPVC connection has slot number out of range. portA-OutofRange(8): A-side of SPVC connection has port number out of range. channelA-OutofRange(9): A-side of SPVC connection has channel number out of range. vpiVciWithInSvcRange(10) : A-side side of SPVC connection has vpi/vci configured in the SVC range of the A-side ATM interface. retryIntervalExceedsTheLimit(11) : retryInterval exceeds 3600s. interfaceNotConfiguredAsCE(12) : SPVC endpoint is configured as something other than CE. interfaceNotConfiguredAsVbr(13) : SPVC endpoint is configured as something other than TE. interfaceNotConfiguredAsAtm(14) : SPVC endpoint is configured as something other than ATM. noAddressConfiguredOnTheInterface(15) : Local address not configured for the particular SPVC being configured. localAddressNotValid(16) : invalid NSAP address format vpiVciUnavailable(17) : SPVC already setup on particular vpi/vci. pvcAlreadySetupOnVpiVci(18) : vpi/vci being used by another pvc. pvcAlreadySetupOnInterface(19) : redundant, same as above. interfaceNotConfiguredAsFr(21) : SPVC endpoint is configured as something other than Fr dlciUnavailable(22) : dlci not available at Passive endpoint. pvcAlreadySetupOnDlci(23) : dlci being used by another pvc. frTrafficParamsUnsupp(24) : fr-atm traffic mapping failure. dsp2ParamsUnsupp(25) : dsp2 params not supported for the call. sarNotConfigReq(26) : sarType not configured as required.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noSpvcConfigured(1), spvcAlreadyConfigured(2), noInterfaceConfigured(3), interfaceNotConfiguredAsRequired(4), notActiveSpvc(6), slotA-OutofRange(7), portA-OutofRange(8), channelA-OutofRange(9), vpiVciWithInSvcRange(10), retryIntervalExceedsTheLimit(11), interfaceNotConfiguredAsCE(12), interfaceNotConfiguredAsVbr(13), interfaceNotConfiguredAsAtm(14), noAddressConfiguredOnTheInterface(15), localAddressNotValid(16), vpiVciUnavailable(17), pvcAlreadySetupOnVpiVci(18), pvcAlreadySetupOnInterface(19), retryIntervalTooSmall(20), interfaceNotConfiguredAsFr(21), dlciUnavailable(22), pvcAlreadySetupOnDlci(23), frTrafficParamsUnsupp(24), dsp2ParamsUnsupp(25), sarNotConfigReq(26), vuniNotMatch(27)  

imaGrpChannelStatus 3.1.1751.2.18.15.18
The return value for the imaGrpChannelFailNotify trap. startupFe(1) Far-end is in the state of start-up cfgAbort(2) this state is entered when the far-end tries to use unacceptable configuration parameters including invalid frame length and incompatable symmetry cfgAbortFe(3) Far-end reported unacceptable configuration parameters including invalid frame length and incompatable symmetry insuffLinks(4) Near-end reported less than the min number of Tx links are active or less than the min number of Rx links are active insuffLinksFe(5) Far-end reported less than the min number of Rx links are active or less than thenmin number of Tx links are active blockedNe(6) Near-end is administratively out-of-service blockedFe(7) Far-end is administratively out-of-service timingSynch(8) A possible configuration mismatch has occurred (CTC and CTC modes are not the same at both ends of the IMA virtual links.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER startupFe(1), cfgAbort(2), cfgAbortFe(3), insuffLinks(4), insuffLinksFe(5), blockedNe(6), blockedFe(7), timingSynch(8)  

atmImaIntfStatus 3.1.1751.2.18.15.19
The return value for the atmImaIntfFailNotify trap. lif -- Persistence of LIF defect at near-end (Loss of IMA Frame) lods -- Persistence of LODS defect at near-end (Link Out of Delay Synchronization) txMisConnect -- The link is mis-connected (not connected to the same far-end as the other links in the group.) rfi -- Persistence of RDI-IMA defect at near-end (Remote Failure Indicator) fault -- Implementation specific fault at near-end txUnusableFe -- Tx link forced to unusable due to far-end behavior rxUnusableFe -- Rx link forced to unusable due to far-end behavior
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER lif(1), lods(2), txMisConnect(3), rfi(4), fault(5), txUnusableFe(6), rxUnusableFe(7)  

deviceId 3.1.1751.2.18.15.20
device ID is used as the number of external devices. Each device can be an external input device or control output device.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

oamTestFailureReasonCode 3.1.1751.2.18.15.21
An identified reason why an OAM Loopback Test request has failed. invalidSPCforOAM: There is no such slot/port/channel in this box. invalidIntfForOAM: There is no such interface that OAM enabled. invalidLocationLength: The length of the Loopback Lo cation ID id not valid. oamNotSupportedForThisConnection: This connection is not OAM enabled.so OAM loopback is invalid test. loopbackTestAlreadyRunning: OAM loopback is waiting for response,not expect for another test. loopbackTestNotRunning: Invalid Test Actio. oamLocalResourcesUnavailable: Memery Alloc Fail.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER invalidSPCforOAM(1), invalidIntfForOAM(2), invalidLocationLength(3), oamNotSupportedForThisConnection(4), loopbackTestAlreadyRunning(5), loopbackTestNotRunning(6), oamLocalResourcesUnavailable(7)  

pnniCode 3.1.1751.2.18.15.22
An identified reason for Miscellaneous Reasons in PNNI Configuration pnniInvEndSysPortId(1) : Invalid EndSystem PortId. pnniNodeAdmStatNotUp(2) : Admin Status of Node is not up. pnniProtLnkStatDown(3) : Pnni Lnk status is down. pnniProtLnkStatUpNotAdv(4) : Pnni Lnk status up but not advertised. pnniProtLinkStatUpAdv(5) : Pnni Lnk status up and advertised. pnniIntfAdmStatUp(6) : Pnni Intf Admin Status up. pnniNodeNotCfg(7) : Pnni Node not configured in the switch. pnniRtAddrAddedByIlmi(8) : Pnni Route added succesfully from ILMI. pnniRtAddrDelByIlmi(9) : Pnni Route deleted succesfully from ILMI. pnniLvlMismatchInNodeId(10) : Level mismatch in Node Id. pnniLvlMismatchInPGId(11) : Level mismatch in Peer Group Id. pnniATMAddrInvInNodeId(12) : ATM Address entered in Node Id invalid. pnniATMAddrInvInPGId(13) : ATM Address entered in Peer Group Id invalid. pnniIntfAdmStatNotDel(14) : Pnni Intf Admin Status Not deleted. pnniNodeAdmStatUp(15) : Pnni Node Admin Status up. pnniNodeRowStatNotActive(16) : Pnni Node Row Status not active - cannot modify pnniNewRtAddrAdded(17) : New route added into pnni route address table. pnniRtAddrMod(18) : Route modified in pnni Address table. pnniAdvtNodeIdNotMine(19) : Advertised NodeId does not belong to this psax. pnniFeatureNotSupported(20) : pnni feature unsupported.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER pnniInvEndSysPortId(1), pnniNodeAdmStatNotUp(2), pnniProtLnkStatDown(3), pnniProtLnkStatUpNotAdv(4), pnniProtLinkStatUpAdv(5), pnniIntfAdmStatUp(6), pnniNodeNotCfg(7), pnniRtAddrAddedByIlmi(8), pnniRtAddrDelByIlmi(9), pnniLvlMismatchInNodeId(10), pnniLvlMismatchInPGId(11), pnniATMAddrInvInNodeId(12), pnniATMAddrInvInPGId(13), pnniIntfAdmStatNotDel(14), pnniNodeAdmStatUp(15), pnniNodeRowStatNotActive(16), pnniNewRtAddrAdded(17), pnniRtAddrMod(18), pnniAdvtNodeIdNotMine(19), pnniFeatureNotSupported(20)  

swtchNodeIndx 3.1.1751.2.18.15.23
Switch Node Index for PNNI.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

oc3APSPairPortIndex 3.1.1751.2.18.15.24
APS Pair Port index - SSPP
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

oc3APSReasonCode 3.1.1751.2.18.15.25
Enumerated values of the outcome of previous apsPair UserCommand or alarms on the line local - near-end remote - far-end working - working port protect - protecting port DoNotRevert - after switching from working line to protection line, don't revert to working line even it returns to work ManualSw - switch over by user command SD - signal degradation SF - signal failure Forced - force switch over LockOut - don't allow switch over to a line
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER localprotectDoNotRevert(1), localprotectManualSw(8), localprotectSD(10), localprotectSF(12), localprotectForced(14), localprotectLockOut(15), localworkingDoNotRevert(17), localworkingManualSw(24), localworkingSD(26), localworkingSF(28), localworkingForced(30), remoteprotectDoNotRevert(33), remoteprotectManualSw(40), remoteprotectSD(42), remoteprotectSF(44), remoteprotectForced(46), remoteprotectLockOut(47), noRequest(48), remoteworkingDoNotRevert(49), remoteworkingManualSw(56), remoteworkingSD(58), remoteworkingSF(60), remoteworkingForced(62)  

oc3APSK1K2Rx 3.1.1751.2.18.15.26
Rx K1/K2 followed by hex value of K1, K2
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(2)  

oc3APSK1K2Tx 3.1.1751.2.18.15.27
Tx K1/K2 followed by hex value of K1, K2
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(2)  

oc3APSSelectorState 3.1.1751.2.18.15.28
Working port: active/standby Protection port: standby/active
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER w-active-p-standby(1), w-standby-p-active(2)  

oc3APSWorkingLineSignalStatus 3.1.1751.2.18.15.29
Line Status of the working port sent in a trap enumeration explanations are the same as those of oc3APSProtectionLineSignalStatus
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), signalDegradation(2), signalFailure(4), lostCellDelineation(8), switchByteFailure(16), ais-l(32), ais-p(64), lop(128), lof(256), los(512), moduleFailure(1024)  

oc3APSProtectionLineSignalStatus 3.1.1751.2.18.15.30
Line Status of the protection port sent in a trap. noAlarm(1) no alarm signalDegradation(2) signal bit error rate is higher than the specified threshold signalFailure(4) signal bit error rate is much higher than the specified threshold lostCellDelineation(8) unable to identify cell boundary switchByteFailure(16) switch bytes(k1,k2) of SONET header have invalid code ais-l(32) line header of SONET frame gives alarm indication signal ais-p(64) path header of SONET frame gives alarm indication signal lop(128) 1)a valid STS or VT pointer can't be obtained by using the pointer interpretation rules and the pointer word doesn't contain all-ones; 2)a number of consecutive with the NDF set to 1001 but not indicating concatenation is received lof(256) loss of frame los(512) loss of signal moduleFailure(1024) module failure
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), signalDegradation(2), signalFailure(4), lostCellDelineation(8), switchByteFailure(16), ais-l(32), ais-p(64), lop(128), lof(256), los(512), moduleFailure(1024)  

arpStatus 3.1.1751.2.18.15.31
Success: Arp Data is Available. Failure: Reply from RS Card timed-out. TryAgain: The request was not honoured as it came too soon (within a sec). Try again after 1 sec and we will return either Success or Noroutes.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER success(1), noArpEntries(2), tryAgain(3)  

routingStatus 3.1.1751.2.18.15.32
Success: Routing Data is Available. Failure: Reply from RS Card timed-out. TryAgain: The request was not honoured as it came too soon (within a sec). Try again after 1 sec and we will return either Success or Noroutes.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER success(1), noRoutes(2), tryAgain(3)  

vpnTrapStatus 3.1.1751.2.18.15.33
Return codes for route server VPN level operations. vpnAddOk(1) VPN Creation OK vpnInternalFailure(2) Memory Corruption Failure vpnTooMany(3) Exceeded Max # of VPNs vpnBadSlot(4) Impossible Slot Number vpnBadId(5) VPN ID Must Be Between 1-6 vpnBadState(6) VPN State Machine Confused vpnBadTimerVal(7) Bad Timer Value: State Machine vpnAlreadyExists(8) VPN Already Exists vpnCantLocate(9), Cannot Find Referenced VPN vpnDelInProgress(10) Deletion In Progress -Must Wait vpnLockedIdle(11) VPN Taken Out Of Service vpnGeneralFailure(12) Reference Prev.Trap For Reason vpnNotAllowed(13) Operation Not Allowed vpnShutting(14) Shutting Down VPN -Must Wait vpnDisabled(15) Some VPN SubSystem Not Working vpnModifyOk(16) Modify Operation OK
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER vpnAddOk(1), vpnInternalFailure(2), vpnTooMany(3), vpnBadSlot(4), vpnBadId(5), vpnBadState(6), vpnBadTimerVal(7), vpnAlreadyExists(8), vpnCantLocate(9), vpnDelInProgress(10), vpnLockedIdle(11), vpnGeneralFailure(12), vpnNotAllowed(13), vpnShutting(14), vpnDisabled(15), vpnModifyOk(16)  

ipIntfStatus 3.1.1751.2.18.15.34
Return codes for route server IP interface operations. intOK(1) Interface OK. intIntFailure(2) Memory Corruption intTooMany(3) Exceeded Max # Of Interfaces intBadSlot(4) Impossible Slot Number intBadId(5), Impossible Interface ID intBadState(6) State Machine Confused intBadTimer(7) Bad Timer Value: State Machine intExists(8) Interface Already Exists intCantFind(9) Unused intDelInProgress(10) Deleting: -Must Wait intLockedIdle(11) Interface Taken Out Of Service intBadNetMask(12) Illegal Network Mask intShutting(13) Shutting Down -Must Wait intDisabled(14) Some Subsystem Not Working intNotHostAddr(15) Host Address Is Missing intBadIpAddr(16) Illegal IP Address intBadRouterId(17) Illegal VPN/Router ID intBadIntfId(18) Illegal Interface ID intCantFindRouter(19) No Corresponding VPN intCantFindIntf(20) Interface Does Not Exist intCantOnSameSubnet(21) Interface Already On This Subnet intCantModIntfAddr(22) Cannot Change Interface Addr intCantModIntfMask(23) Cannot Change Interface Mask intCantModIntfRipVer(24) Cannot Change Rip Ver #
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER intOK(1), intIntFailure(2), intTooMany(3), intBadSlot(4), intBadId(5), intBadState(6), intBadTimer(7), intExists(8), intCantFind(9), intDelInProgress(10), intLockedIdle(11), intBadNetMask(12), intShutting(13), intDisabled(14), intNotHostAddr(15), intBadIpAddr(16), intBadRouterId(17), intBadIntfId(18), intCantFindRouter(19), intCantFindIntf(20), intCantOnSameSubnet(21), intCantModIntfAddr(22), intCantModIntfMask(23), intCantModIntfRipVer(24)  

subChanStatus 3.1.1751.2.18.15.35
Return codes for route server sub channel connections operations. scOK(1) SubChannel OK scIntFailure(2) Memory Corruption scTooMany(3) Too Many SubChannels scBadSlot(4) Impossible Slot Number scBadId(5) Bad VPN ID scBadState(6), State Machine Confusion scBadTimerVal(7) Bad Timer Value: State Machine scExists(8) SubChannel Already Exists scCantFind(9) Unused scDelInProgress(10) Deleting: -Must Wait scLockedIdle(12) SubChannel Taken Out Of Serv. scSameVc(13) Connection In Use Already scFailedSetup(14) Referene Previous Trap scShutting(15) Shutting Down: -Must Wait scDisabled(16) SubSystem Disabled. scSetupErr(17) scRemvErr(18) Error Removing SubChannel scBadPortNo(19) Bad Port Specified scBadImIpAddr(20) Bad InBand IP Address scBadRouterId(21) Bad VPN/Router ID scBadIntfId(22) Impossible Interface ID scBadChanId(23) Impossible Channel ID scCantFindRouter(24) Cannot Find VPN scCantFindIntf(25) Cannot Find Interface scCantFindChan(26) Cannot Find SubChannel
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER scOK(1), scIntFailure(2), scTooMany(3), scBadSlot(4), scBadId(5), scBadState(6), scBadTimerVal(7), scExists(8), scCantFind(9), scDelInProgress(10), scLockedIdle(12), scSameVc(13), scFailedSetup(14), scShutting(15), scDisabled(16), scSetupErr(17), scRemvErr(18), scBadPortNo(19), scBadImIpAddr(20), scBadRouterId(21), scBadIntfId(22), scBadChanId(23), scCantFindRouter(24), scCantFindIntf(25), scCantFindChan(26)  

routeSrvStatus 3.1.1751.2.18.15.36
Return codes for basic route server task operations not related to any specific VPN or IP/Connection operation. rsCardOK(1) Route Server OK rsModInitFail(2) Route Server Failed Module Init. rsIntfInitFail(3) Route Server Failed Intf. Init. rsPortInitFail(4) Route Server Failed Port Init rsRipUpdateIntOK(5) Rip Update Interval was updated ok for the route server card. rsRipUpdateIntFail(6) Rip Update Interval was not updated mostly because of some VPN's still in service.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER rsCardOK(1), rsModInitFail(2), rsIntfInitFail(3), rsPortInitFail(4), rsRipUpdateIntOK(5), rsRipUpdateIntFail(6)  

apsFailureReasonCode 3.1.1751.2.18.15.37
Identification of cause for automatic protection switching failure. protectionCard-notPresent(1) protection card doesn't exist protectionCardType-notAPS(2) card type of protection card is not APS protectionCardType-incompatible(3) card types of protection card and working card are incompatible protectionCard-notInUnconfiguredState(4) protection card is already configured protectionCard-notUnprotected(5) protection card is not unprotected resource-access-failure(6) internal failure application incorrect-APSconfiguration(7) correct aps configuration: 1)oc3APSConfiguration of working port is working and oc3APSConfiguration of protection port is protection 2) oc3APSConfiguration of working and protection ports are unprotected protectionPort-Active(8) protection port must be inactive when breaking aps pair workingPort-localLoop-notAllowed(9) working port can't be configured as localLoop protectionPort-localLoop-notAllowed(10) protection port can't be configured as localLoop either
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER protectionCard-notPresent(1), protectionCardType-notAPS(2), protectionCardType-incompatible(3), protectionCard-notInUnconfiguredState(4), protectionCard-notUnprotected(5), resource-access-failure(6), incorrect-APSconfiguration(7), protectionPort-Active(8), workingPort-localLoop-notAllowed(9), protectionPort-localLoop-notAllowed(10)  

statRtStatus 3.1.1751.2.18.15.38
Return codes for route server static route condititions. statRtOk(1) Static Rt OK statRtIntFailure(2) Memory Corruption statRtMany(3) Too Many Static Routes statRtSlot(4) Impossible Slot ID statRtBadId(5) Bad VPN ID statRtBadState(6) State Machine Confusion statRtBadTimer(7) Bad Timer Value: State Machine statRtExists(8) Static Rt Already Exists statRtCantFind(9) Unused statRtDelInProgress(10) Deleting: -Must Wait statRtLockedIdle(11) Static Rt Taken Out Of Service statRtBadNetMask(12) Bad Network Mask statRtCorrelation(13) Internal Correlation Error statRtShutting(14) Shutting Down: -Must Wait statRtDisabled(15) SubSystem Failure statRtBadMetric(16) Illegal Metric Value statRtBadIPAddr(17) Bad Static Route IP Address intfRtExists(18) Static Route On Different Intf. statRtBadSlot(19) Impossible Slot ID statRtBadRouterId(20) Bad VPN/Router ID statRtBadRouteId(21) Illegal Static Route ID statRtBadRouteNetMask(22) Bad Stat Route Network Mask statRtBadRouteIpAddr(23) Bad Interface IP Address statRtBadGtwyIpAddr(24) Bad Gateway IP Address statRtBadDestIpAddr(25) Bad Destination IP Address statRtBadDestNetMask(26) Bad Destination IP Mask statRtCantFindRouter(27) Cannot Find VPN statRtCantFindRoute(28) Cannot Find Static Route
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER statRtOk(1), statRtIntFailure(2), statRtMany(3), statRtSlot(4), statRtBadId(5), statRtBadState(6), statRtBadTimer(7), statRtExists(8), statRtCantFind(9), statRtDelInProgress(10), statRtLockedIdle(11), statRtBadNetMask(12), statRtCorrelation(13), statRtShutting(14), statRtDisabled(15), statRtBadMetric(16), statRtBadIPAddr(17), intfRtExists(18), statRtBadSlot(19), statRtBadRouterId(20), statRtBadRouteId(21), statRtBadRouteNetMask(22), statRtBadRouteIpAddr(23), statRtBadGtwyIpAddr(24), statRtBadDestIpAddr(25), statRtBadDestNetMask(26), statRtCantFindRouter(27), statRtCantFindRoute(28)  

portFailureReasonCode 3.1.1751.2.18.15.39
Identification of cause for failure in changing the parameters of a port insufficientModuleBandwidth(1) insufficient module bandwidth localLoopNotAllowedWhenInAPS(2) local loop is not allowed when a port is in an automatic switching pair. msBitStuffingEnabledOnlyForCE(3) if msBitStuffing is enabled, only interface type circuit emulation is allowed invalidOption(4) invalid option hasInterfaceInService(5) interface is in-service unsupportedBaudRate(6) the baud rate is not supported msLOSDetectionNotEnabled(7) msLOSDetection is not enabled
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER insufficientModuleBandwidth(1), localLoopNotAllowedWhenInAPS(2), msBitStuffingEnabledOnlyForCE(3), invalidOption(4), hasInterfaceInService(5), unsupportedBaudRate(6), msLOSDetectionNotEnabled(7)  

dlciNumber 3.1.1751.2.18.15.40
The number of the dlci being used.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ipAddrNumber 3.1.1751.2.18.15.41
The IP address of the host/network to be echoed
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

pingStatusReasonCode 3.1.1751.2.18.15.42
The response value - Alive destination can be reached Not Alive destination can't be reached
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER alive(1), not-Alive(2)  

primarySoftwareVersion 3.1.1751.2.18.15.43
Software version running on primary cpu.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(20)  

backupSoftwareVersion 3.1.1751.2.18.15.44
Software version running on backup cpu.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(20)  

oamActDeactResultCode 3.1.1751.2.18.15.45
Various result codes for the operator's command for OAM Activation-Deactivation. eteCCActSuccTowardsFarEnd: eteCCActSuccTowardsNearEnd: eteCCActSuccTowardsBothEnd: eteCCDeactSuccTowardsFarEnd: eteCCDeactSuccTowardsNearEnd: eteCCDeactSuccTowardsBothEnd: ete CC Act/Deact-request send out to far/near/both end eteCCActDeniedTowardsFarEnd: eteCCActDeniedTowardsNearEnd: eteCCActDeniedTowardsBothEnd: eteCCDeactDeniedTowardsFarEnd: eteCCDeactDeniedTowardsNearEnd: eteCCDeactDeniedTowardsBothEnd: ete CC Act/Deact-request is denied. eteCCActFailedTowardsFarEnd: eteCCActFailedTowardsNearEnd: eteCCActFailedTowardsBothEnd: eteCCDeactFailedTowardsFarEnd: eteCCDeactFailedTowardsNearEnd: eteCCDeactFailedTowardsBothEnd: ete CC Act/Deact-request is failed sent out segCCActSuccTowardsFarEnd: segCCActSuccTowardsNearEnd: segCCActSuccTowardsBothEnd: segCCDeactSuccTowardsFarEnd: segCCDeactSuccTowardsNearEnd: segCCDeactSuccTowardsBothEnd: segment CC Act/Deact-request send out to far/near/both end. segCCActDeniedTowardsFarEnd: segCCActDeniedTowardsNearEnd: segCCActDeniedTowardsBothEnd: segment CC Act-request is denied. segCCActFailedTowardsFarEnd: segCCActFailedTowardsNearEnd: segCCActFailedTowardsBothEnd: ete CC Act-request is failed sent out. oamReqFunctionNotImplemented: The function user issued is not impemeted. oamActDeactPrevReqInProgress: this interface is in wait for response state. SendPMCell: a management cell has been sent out to IO card indicating PM cell need to be sent. eteReceiveBRErrMessage: a BR message has been forwarded to CPU indicating BR error. receiveFPMErrMessage: a FPM message has been forwarded to CPU indicating FPM error.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER eteCCActSuccTowardsFarEnd(1), eteCCActSuccTowardsNearEnd(2), eteCCActSuccTowardsBothEnd(3), eteCCActDeniedTowardsFarEnd(4), eteCCActDeniedTowardsNearEnd(5), eteCCActDeniedTowardsBothEnd(6), eteCCActFailedTowardsFarEnd(7), eteCCActFailedTowardsNearEnd(8), eteCCActFailedTowardsBothEnd(9), eteCCDeactSuccTowardsFarEnd(10), eteCCDeactSuccTowardsNearEnd(11), eteCCDeactSuccTowardsBothEnd(12), eteCCDeactDeniedTowardsFarEnd(13), eteCCDeactDeniedTowardsNearEnd(14), eteCCDeactDeniedTowardsBothEnd(15), eteCCDeactFailedTowardsFarEnd(16), eteCCDeactFailedTowardsNearEnd(17), eteCCDeactFailedTowardsBothEnd(18), segCCActSuccTowardsFarEnd(19), segCCActSuccTowardsNearEnd(20), segCCActSuccTowardsBothEnd(21), segCCActDeniedTowardsFarEnd(22), segCCActDeniedTowardsNearEnd(23), segCCActDeniedTowardsBothEnd(24), segCCActFailedTowardsFarEnd(25), segCCActFailedTowardsNearEnd(26), segCCActFailedTowardsBothEnd(27), segCCDeactSuccTowardsFarEnd(28), segCCDeactSuccTowardsNearEnd(29), segCCDeactSuccTowardsBothEnd(30), oamReqFunctionNotImplemented(31), oamReqFailLocRsrcUnavl(32), oamActDeactPrevReqInProgress(33), oamActDeactInvalidParams(34), oamActDeactInvalidIntf(35), oamNotSupportedForThisConnection(36), oamCCnotSupportedForThisConnection(37), oamPrevActDeactReqFailed(38), oamEteLossOfContinuitySet(39), oamEteLossOfContinuityCleared(40), oamSegLossOfContinuitySet(41), oamSegLossOfContinuityCleared(42), oamActDeactPMOnlySupportOC3(43), oamPMnotSupportedForThisConnection(44), oamPMBRnotSupportedForThisConnection(45), etePMActSuccTowardsFarEnd(46), etePMActSuccTowardsNearEnd(47), etePMActSuccTowardsBothEnd(48), etePMActDeniedTowardsFarEnd(49), etePMActDeniedTowardsNearEnd(50), etePMActDeniedTowardsBothEnd(51), etePMActFailedTowardsFarEnd(52), etePMActFailedTowardsNearEnd(53), etePMActFailedTowardsBothEnd(54), etePMDeactSuccTowardsFarEnd(55), etePMDeactSuccTowardsNearEnd(56), etePMDeactSuccTowardsBothEnd(57), etePMBRActSuccTowardsFarEnd(58), etePMBRActSuccTowardsNearEnd(59), etePMBRActSuccTowardsBothEnd(60), etePMBRActDeniedTowardsFarEnd(61), etePMBRActDeniedTowardsNearEnd(62), etePMBRActDeniedTowardsBothEnd(63), etePMBRActFailedTowardsFarEnd(64), etePMBRActFailedTowardsNearEnd(65), etePMBRActFailedTowardsBothEnd(66), etePMBRDeactSuccTowardsFarEnd(67), etePMBRDeactSuccTowardsNearEnd(68), etePMBRDeactSuccTowardsBothEnd(69), segPMActSuccTowardsFarEnd(70), segPMActSuccTowardsNearEnd(71), segPMActSuccTowardsBothEnd(72), segPMActDeniedTowardsFarEnd(73), segPMActDeniedTowardsNearEnd(74), segPMActDeniedTowardsBothEnd(75), segPMActFailedTowardsFarEnd(76), segPMActFailedTowardsNearEnd(77), segPMActFailedTowardsBothEnd(78), segPMDeactSuccTowardsFarEnd(79), segPMDeactSuccTowardsNearEnd(80), segPMDeactSuccTowardsBothEnd(81), segPMBRActSuccTowardsFarEnd(82), segPMBRActSuccTowardsNearEnd(83), segPMBRActSuccTowardsBothEnd(84), segPMBRActDeniedTowardsFarEnd(85), segPMBRActDeniedTowardsNearEnd(86), segPMBRActDeniedTowardsBothEnd(87), segPMBRActFailedTowardsFarEnd(88), segPMBRActFailedTowardsNearEnd(89), segPMBRActFailedTowardsBothEnd(90), segPMBRDeactSuccTowardsFarEnd(91), segPMBRDeactSuccTowardsNearEnd(92), segPMBRDeactSuccTowardsBothEnd(93), eteSendPMCell(94), eteReceiveBRErrMessage(95), receiveBRErrMessage(96), receiveFPMErrMessage(97), sendPMCell(98)  

tasCmprsAnnceReasonCode 3.1.1751.2.18.15.46
The result of a compress announcement request.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER cmprs-success(1), cmprs-Fail-equipment-Fail(2), cmprs-Fail-connections-Fail(3), cmprs-Fail-resource-busy(4), cmprs-Fail-resource-unavail(5)  

tasTstLineReasonCode 3.1.1751.2.18.15.47
The result of a test line request.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER tst-success(1), tst-Fail-equipment-Fail(2), tst-Fail-invalid-params(3), tst-Fail-resource-unavail(4), tst-Fail-resource-busy(5)  

gr303PPSReasonCode 3.1.1751.2.18.15.48
These reason codes are the result of GR303 Path Protection Switching (PPS) command issued by user
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER forced(1), normal(2), userCommandFailed-inhibited(3), userCommandFailed-PathOos(4), userCommandFailed-badPathId(5), userCommandFailed-maxRetry(6), userCommandFailed-inprogress(7), userCommandFailed-unknown(8)  

gr303PPSSource 3.1.1751.2.18.15.49
Indicates the initiator of the PPS switching
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), byIdt(2), byUser(3), byLocalAgent(4), suspendedByIdt(5), suspendedByLocalAgent(6)  

tasMemReasonCode 3.1.1751.2.18.15.50
The result of a memory init request.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER mem-init-success(1), mem-init-Fail(2)  

tasTrapTstId 3.1.1751.2.18.15.51
Announcement ID for trap.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..100  

tasTrapAnnceId 3.1.1751.2.18.15.52
test id for trap.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..100  

atmVpi 3.1.1751.2.18.15.53
Vpi is used in identification of Traps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..4095  

atmVci 3.1.1751.2.18.15.54
Vci is used in identification of Traps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

iptResultCode 3.1.1751.2.18.15.55
Various result codes for the operator's command forsetting/deleting interface protection group. interfaceProtectioniptAlreadyExistInterface: Expect another interface to be protected. interfaceProtectioniptInvalidInterface:interface invalid interfaceProtectioniptInvalidParams: invalid Parameters interfaceProtectioniptTryToDeleteEmptyTable:Table is already empty,can not be deleted . interfaceProtectioniptInvalidConfiguation: interfaceProtectioniptSuccessfulSwichOver: interface is switched over to the secondry interface. interfaceProtectioniptSuccessfulSwichBack: interface is switched back from secondry interface. interfaceProtectioniptFailedSwichOver: interface is failed switched over to the secondry interface. interfaceProtectioniptFailedSwichBack: interface is failed switched back from secondry interface.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER interfaceProtectioniptAlreadyExistInterface(1), interfaceProtectioniptInvalidInterface(2), interfaceProtectioniptInvalidParams(3), interfaceProtectioniptTryToDeleteEmptyTable(4), interfaceProtectioniptInvalidConfiguation(5), interfaceProtectioniptSuccessfulSwichOver(6), interfaceProtectioniptSuccessfulSwichBack(7), interfaceProtectioniptFailedSwichOver(8), interfaceProtectioniptFailedSwichBack(9)  

pgtResultCode 3.1.1751.2.18.15.56
Various result codes for the operator's command for interface protection .
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER interfaceProtectionpgtAlreadyExistInterface(1), interfaceProtectionpgtInvalidInterface(2), interfaceProtectionpgtInvalidParams(3), interfaceProtectionpgtryToDeleteEmptyTable(4), interfaceProtectionpgtSuccessfulSwichOver(5), interfaceProtectionpgtSuccessfulSwichBack(6), interfaceProtectionpgtFailedSwichOver(7), interfaceProtectionpgtFailedSwichBack(8), interfaceProtectionpgtInvalidConfiguation(9)  

tasmControlBlockAllocFailReasonCode 3.1.1751.2.18.15.57
The result of a tasm control block memory allocation request.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER res-alloc-success(1), res-alloc-Fail-announce-control-blocks-mem-unavail(2), res-alloc-Fail-digit-control-blocks-mem-unavail(3), res-alloc-Fail-line-test-control-blocks-mem-unavail(4)  

tasmCacheMemAllocFailReasonCode 3.1.1751.2.18.15.58
The result of a tasm control block memory allocation request.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER res-alloc-success(1), res-alloc-Fail-announce-cache-mem-unavail(2)  

atmTrunkingConfigFailureCode 3.1.1751.2.18.15.59
An identified reason for failure while configuring/modifying ATM Trunking parameters: localIWFAlreadyConfigured(1) : Local IWF has already been configured, the parameters can not be changed or apply again. localIWFAtmAddressError(2): the ATM Address for Local IWF is not valid or this address has been used by someone else. localIWFIdOutOfRange(3): the Identification of Local IWF is out of range. maxNumberRmtIWFOutOfRange(4): the maximum number of Remote IWF is out of range. rmtIWFAlreadyConfigured(5): this remote IWF has already been configured( with index atmTrunkingRmtIWFIdentifier). rmtIWFIdOutOfRange: the identifier for the remote IWF is out of range. rmtIWFAtmAddressError: the ATM Address for remote IWF is not valid or this address has been used by someone else. vccIdError: the VCC ID for the SigVcc or BrVcc is 0, or this VCC ID is out of range or it has been used by someone else. vccPvcParameterNotAcceptable: the parameters of PVC side, including slot, port, channel, vpi, vci, are not acceptable. vccTrafficParameterNotValid: the VCC traffic parameters are not acceptable, including FwPcr01, BwPcr01, FwScr01, BwScr01, FWMbs01, BwMbs01, BrVccServiceType, BrVccSarType. vccViVuniNotValid: the configuration of Egress Vi/VUNI is not acceptable. vccTrunkParameterNotValid: the parameters for the Trunk is not supported, including BrVccMaxAal2ChanId, BrVccCircuitModeDataSupp, BrVccFrameModeSupp, BrVccFaxModeSupp, CASPktXportSupp, BrVccDTMFPktXportSupp, BrVccMFR1PktXportSupp, BrVccMFR2PktXportSupp, BrVccPCMEncoding, BrVccMaxFrameLength, BrVccIdleChannSuprSupp, BrVccSilenceDetSupp, BrVccCompressionSpec,AudioProfileId, SigVccSignaling. vccTrunkFeatureParameterNotValid: PSAX proprietary feature parameters not supported including SigVccInactiveTimer, SigVccRetryTimer, SigVccRetryLimit, BrVccInactiveTimer, BrVccRetryTimer, BrVccRetryLimit, BrVccGr303Supp, BrVccOamStatus. localIwfNotConfigured(14) : Local IWF not Configured localIwfIdNotMatch(15): specified Local IWF not match localIwfStatus(16): this operation is not supported because of the status of Local IWF rmtIwfNotConfigured(17): Remote IWF Not Configured rmtIwfModeNotCompatible(18): the Mode of Remote IWF is not compatiable rmtIwfStatus(19): this operation is not support because of the Status of Remote IWF vccAlreadyConfigured(20): This VCC has been configured vccPvcCacReject(21): PVC Configuration rejected by Cac Reservation Function requiredFieldMissing(22): mandatory fields missing outOfResource(23): Atm Trunking Task or System out of resource for this configuration rowStatusError(24):Row Status Error with the SNMP command generalErrorUnspecified(25): all other unspecified failure cause.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER localIWFAlreadyConfigured(1), localIWFAtmAddressError(2), localIWFIdOutOfRange(3), maxNumberRmtIWFOutOfRange(4), rmtIWFAlreadyConfigured(5), rmtIWFIdOutOfRange(6), rmtIWFAtmAddressError(7), vccIdError(8), vccPvcParameterNotAcceptable(9), vccTrafficParameterNotValid(10), vccViVuniNotValid(11), vccTrunkParameterNotValid(12), vccTrunkFeatureParameterNotValid(13), localIwfNotConfigured(14), localIwfIdNotMatch(15), localIwfStatus(16), rmtIwfNotConfigured(17), rmtIwfModeNotCompatible(18), rmtIwfStatus(19), vccAlreadyConfigured(20), vccPvcCacReject(21), requiredFieldMissing(22), outOfResource(23), rowStatusError(24), generalErrorUnspecified(25)  

sapphireIntfAddressFailReasonCode 3.1.1751.2.18.15.60
The result of assigning the Sapphire Interface address when PSAX is Sapphire client. address-ok(1), Address assignment succeeded fail-Ilegal-IP-address(2), Illegal IP address assigned address not matching fail-not-match-InBandManagement-Switch-CPU-IP-Address(3) In-Band Management IP or Switch IP or CPU IP address fail-Switch-or-CPU-IP-Address-unconfigured(4) Switch IP or CPU IP address unconfigured fail-InBandManagement-IP-Address-unconfigured(5) InBandManagement IP address unconfigured.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER address-assign-ok(1), fail-Ilegal-IP-address(2), fail-not-match-InBandManagement-Switch-Cpu-IP-Address(3), fail-Switch-or-Cpu-IP-Address-unconfigured(4), fail-InBandManagement-IP-Address-unconfigured(5)  

chassisOverTempAlarmReasonCode 3.1.1751.2.18.15.61
Indicator of presence of chassis over temperature alarm.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER set(1), clear(2)  

saveConfiguration 3.1.1751.2.18.16.1
save configuration
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER equipment(1), connections(2), routing(3), all(4)  

upgradeSoftware 3.1.1751.2.18.16.2
software load management
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER upgrade(1), fallBack(2), forceUpgrade(3), forceFallBack(4), synchronize(5), abort(6), forceSynchronize(7), forceAbort(8)  

purgePvcConnections 3.1.1751.2.18.16.3
purge PVC connections on indicated interface
Status: current Access: read-write
OBJECT-TYPE    
  IntfIndex  

purgeRoutingTable 3.1.1751.2.18.16.4
purge indicated routing table
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER iispCbr(1), iispVbr(2)  

resetPortStatistics 3.1.1751.2.18.16.5
Reset the statistics counters for the given port Id (SSPP)
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

resetInterfaceStatistics 3.1.1751.2.18.16.6
Reset the interface counters for the given port Id (SSPPCCC)
Status: current Access: read-write
OBJECT-TYPE    
  IntfIndex  

resetAllStatistics 3.1.1751.2.18.16.7
Reset all port and interface statistics counters, accpets any integer value
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

upgradeIpAddress 3.1.1751.2.18.16.8
IP Address for upgrade ftp server.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

upgradeAccountName 3.1.1751.2.18.16.9
ftp account name for access to upgrade ftp server.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(20)  

upgradeAccountPassword 3.1.1751.2.18.16.10
ftp account password for access to upgrade ftp server.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(20)  

upgradeCdromFile 3.1.1751.2.18.16.11
cdrom file path on upgrade ftp server to upgrade image library.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(79)  

upgradeLicenseKey 3.1.1751.2.18.16.12
software license key.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(30)  

upgradeSwCopyStatus 3.1.1751.2.18.16.13
Current status of the ftp software upgrade download. Status of the software upgrade. noActivity is the initial start state from boot-up. working is set while ftp'ing the upgrade. The final state is one of doneSuccessfully, doneWithError, or aborted, all self-explanatory. It will stay in this state until re-boot or starting an upgrade. If the state is doneWithError then upgradeSwErrorStatus will be set to reflect the type of error.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noActivity(1), working(2), doneSuccessfully(3), doneWithError(4), aborted(5)  

upgradeSwErrorStatus 3.1.1751.2.18.16.14
The result of the finish of the ftp software upgrade download. Set to a value 3-22 if upgradeSwCopyStatus is doneWithError. Set to none if upgradeSwCopyStatus is doneSuccessfully. Set to userAbort if upgradeSwCopyStatus is aborted.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), userAbort(2), invalidIpAddress(3), invalidAccountName(4), invalidAccountPassword(5), invalidCdromFile(6), libraryCRCFail(7), unableToOpenLibraryFile(8), unableToLoadLibraryModule(9), unableToFindTaskSymbolName(10), failureInSpawningTask(11), failureInCreatingMsgQ(12), failureInCopyingDataFiles(13), failureToRemoveNextTree(14), unableToMakeNextTree(15), unableToOpenFile(16), unableToMakeFtpConnection(17), unableToWriteFile(18), unableToCompleteFtp(19), fileCRCFail(20), unableToWritePackageList(21), taskSuspendOrDead(22), unableToUpdateBackup(23), cpuAbort(24), failureToTakeSemaphore(25), failureToRemoveFallBackTree(26), unableToMakeFallBackTree(27)  

systemSwCopy 3.1.1751.2.18.16.15
start copy system files according to the profile. When upgradeSwCopyStatus is working, the start request will be ignored. Abort will have effect only when upgradeSwCopystatus is working.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER start(1), abort(2)  

fwReleaseTable 3.1.1751.2.18.16.16
Table of firmware inventory data
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FwReleaseEntry

fwReleaseEntry 3.1.1751.2.18.16.16.1
Row definition for firmware inventory
Status: current Access: not-accessible
OBJECT-TYPE    
  FwReleaseEntry  

fwReleaseSlot 3.1.1751.2.18.16.16.1.1
Physical slot location. Valid range is a number between 1 and 16.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..16  

fwReleaseRunning 3.1.1751.2.18.16.16.1.2
the firmware release currently running in a physical slot (e.g., 01.03.C01).
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(15)  

fwReleaseEpromVersion 3.1.1751.2.18.16.16.1.3
the version of the firmware located on the I/O card (e.g., 01.03.C01).
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(9)  

fwReleaseCurrentVersion 3.1.1751.2.18.16.16.1.4
the version of the firmware located in /scsi/current/io on the CPU disk drive (e.g., 01.03.C01).
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(9)  

fwReleaseNextVersion 3.1.1751.2.18.16.16.1.5
the version of the firmware located in /scsi/next/io on the CPU disk drive (e.g., 01.03.C01).
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(9)  

fwReleaseUpdate 3.1.1751.2.18.16.16.1.6
Update the fwReleaseCurrentVersion and the fwReleaseNextVersion variables by remapping the firmware files from the CPU disk drive.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER activate(1)  

fwReleaseUpgrade 3.1.1751.2.18.16.16.1.7
Update the fwReleaseCurrentVersion and the fwReleaseNextVersion variables by remapping the firmware files from the CPU disk drive.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER eprom(1), current(2), next(3)  

resetBridgeDomainStatistics 3.1.1751.2.18.16.17
Resets bridge domain statistics.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

remoteRebootCommand 3.1.1751.2.18.16.18
type of reboot.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ioCard1Reboot(1), ioCard2Reboot(2), ioCard3Reboot(3), ioCard4Reboot(4), ioCard5Reboot(5), ioCard6Reboot(6), ioCard7Reboot(7), ioCard8Reboot(8), ioCard9Reboot(9), ioCard10Reboot(10), ioCard11Reboot(11), ioCard12Reboot(12), ioCard13Reboot(13), ioCard14Reboot(14), ioCard15Reboot(15), ioCard16Reboot(16), allIOCardReboot(100), chassisReboot(101), backupCpuReboot(102), primaryCpuReboot(103), primaryCpuSwitchover(200)  

resetFrLmiStatistics 3.1.1751.2.18.16.19
Reset the frame relay LMI statistics counters for the given port Id (SSPPCCC)
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

removeConfigurationFiles 3.1.1751.2.18.16.20
Removes the user configuration/connection files from the hard disk on the cpu.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER all(1)  

systemFilesDirtyBitStatus 3.1.1751.2.18.16.21
Bit mask for system files: 0: all are clean 1: console.def 2: ecd.def 4: ssid.def 8: cnctn.db 16: iisp.cbr 32: iisp.vbr 64: spvc.db 128: vipr.cfg 256: fwc.def 512: vi.db 1024: iproute.db 2048: atmvuni.db
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..4096  

resetAtmIlmiStatistics 3.1.1751.2.18.16.22
Reset the ATM ILMI statistics counters for the given channel Id (SSPPCCC)
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

resetImaGrpChannelStatistics 3.1.1751.2.18.16.23
Reset the IMA Group Statistics counters for the given port Id (SSPPCCC)
Status: current Access: read-write
OBJECT-TYPE    
  IntfIndex  

oc3APSResetStats 3.1.1751.2.18.16.24
Reset the oc3aps Group Statistics counters for the given port Id (SSPP)
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

resetsonetSectionStatistics 3.1.1751.2.18.16.25
Reset the sonetSectionCurrent Statistics counters for the given port Id (SSPP)
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

resetsonetLineStatistics 3.1.1751.2.18.16.26
Reset the sonetLineCurrent Statistics counters for the given port Id (SSPP)
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

resetsonetVTPathStatistics 3.1.1751.2.18.16.27
Reset the sonetVTPathCurrent Statistics counters for the given port Id (SSPP)
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

viprVpnReset 3.1.1751.2.18.16.28
Reset the VPN statistics for VPN specified by (SSVV)
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

svcRetBackupStatus 3.1.1751.2.18.16.29
Indicates backup status wrt SVC retention
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER no-sync(1), sync-in-progress(2), fully-sync(3)  

resetsonetPathStatistics 3.1.1751.2.18.16.30
Reset the sonetPathCurrent Statistics counters for the given port Id (SSPP)
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

ambientTemperature 3.1.1751.2.18.16.31
Ambient temperature in degree Celcius where the system is kept
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

remoteDbServerGroup 3.1.1751.2.18.16.32
OBJECT IDENTIFIER    

remoteDbServerIpAddress 3.1.1751.2.18.16.32.1
IP Address for remote database server.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

remoteDbServerLogin 3.1.1751.2.18.16.32.2
ftp account name for remote database server.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(20)  

remoteDbServerPassword 3.1.1751.2.18.16.32.3
ftp account password for remote database server.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(20)  

remoteDbServerDirectory 3.1.1751.2.18.16.32.4
directory on remote database server where to save/restore database files from.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(79)  

remoteDbCommand 3.1.1751.2.18.16.32.5
remote database operation.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noOperation(1), remoteSave(2), remoteLoad(3)  

remoteDbOperationStatus 3.1.1751.2.18.16.32.6
Current status of remote database command.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noActivity(1), working(2), doneSuccessfully(3), doneWithError(4), aborted(5)  

remoteDbOperationErrorStatus 3.1.1751.2.18.16.32.7
The result at the finish of remote database operation.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(0), unableToMakeFtpConnection(1), invalidDirectory(2), unableToOpenDatabaseFile(3), unableToCompleteFtp(4), databaseSanityFail(5), unableToUpdateBackup(6)  

stratumSyncSource 3.1.1751.2.18.17.1
Clock source for the stratum card - lineTiming: must have slot and port specified in stratumPrimaryLineId. compositeClock: local clock must be available.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER lineTiming(1), compositeClock(2), freerun(3), t1BITS(4), e1ETSI(5)  

stratumPrimaryLineId 3.1.1751.2.18.17.2
Format SSPP (slot and port #'s) to be used when lineTiming is specified in stratumSyncSource.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

stratumSecondaryLineId 3.1.1751.2.18.17.3
Format SSPP (slot and port #'s) to be used if the primary line has failed. Zeros imply that the stratum should switch to holdover mode instead.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

stratumLevel 3.1.1751.2.18.17.4
Enable or disable the switching over to stratum 4 when stratum 3 is not possible.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER stratum3(1), stratum4(2)  

stratumLineCommand 3.1.1751.2.18.17.5
Forces the stratum card to use one of the two specified lines as its clock source when the stratumSyncSource is lineTiming.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER gotoPrimaryLine(1), gotoSecondaryLine(2)  

stratumLineTimingStatus 3.1.1751.2.18.17.6
Represents the source of the current clock.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER primaryLine(1), secondaryLine(2), none(3)  

stratumMode 3.1.1751.2.18.17.7
Current status of the primary stratum card. synchronized3(1) stratum is synchronized with accuracy 4.6 x 10e-6 synchronized4(2) stratum is synchronized with accuracy 3.2 x 10e-5 holdover(3) an operating condition of a clock that has lost its controlling input and is using stored data acquired while in normal operation, to control its output freerun(4) an operating condition of the clock whose output signals are internally controlled cardRemoved(5) stratum removed
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER synchronized3(1), synchronized4(2), holdover(3), freerun(4), cardRemoved(5)  

stratumBackupMode 3.1.1751.2.18.17.8
Current status of the backup stratum card.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER synchronized3(1), synchronized4(2), holdover(3), freerun(4), cardRemoved(5)  

stratumRefFailAction 3.1.1751.2.18.17.9
Defines whether the stratum should switch to freerun or holdover on reference clock failure.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER holdover(1), freerun(2)  

stratumPortStatus 3.1.1751.2.18.17.10
Current status of the primary stratum card. portFOS indicates port frequency offset.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unconfigured(1), noalarm(2), portAIS(3), portLOF(4), portLOS(5), portFOS(6)  

stratumBkupPortStatus 3.1.1751.2.18.17.11
Current status of the backup stratum card. portFOS indicates port frequency offset.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unconfigured(1), noalarm(2), portAIS(3), portLOF(4), portLOS(5), portFOS(6)  

activeStratum 3.1.1751.2.18.17.12
Current status of the backup stratum card.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER stratumA(1), stratumB(2)  

cellTestIfB 3.1.1751.2.18.18.1
Interface index used for testing cell transfer. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: read-write
OBJECT-TYPE    
  IntfIndex  

cellTestVpiB 3.1.1751.2.18.18.2
VPI value for testing cell transfer to an I/O card. Valid range is a number between 0 and 4095. If the I/O card interface is not ATM, then this will always be zero.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

cellTestVcidB 3.1.1751.2.18.18.3
Virtual Check Id for testing cell transfer to an I/O card. Valid range is a number between 0 and 65535. If the I/O card interface is frame relay, this field acts as DLCI and the valid range is a number between 0 and 1023. If the I/O card interface is circuit emulation, then this will always be 0.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

cellTestServiceType 3.1.1751.2.18.18.4
Service types for testing cell transfer
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ubr(1), vbr-nrt2(2), vbr-nrt1(3), vbr-rt2(4), vbr-rt1(5), vbr-express(6), cbr4(7), cbr3(8), cbr2(9), cbr1(10)  

cellTestConnType 3.1.1751.2.18.18.5
Connection types for testing cell transfer
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER simplexTx(1), simplexRx(2), duplex(3)  

cellTestProtocol 3.1.1751.2.18.18.6
Protocol (interface type) on the I/O
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER atm(1), frame-relay(2), hdlc(4)  

cellTestPayLoadTx 3.1.1751.2.18.18.7
PayLoad to be transmitted on I/O interface
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(88)  

cellTestPayLoadRx 3.1.1751.2.18.18.8
Last PayLoad received on I/O interface
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(88)  

cellTestAction 3.1.1751.2.18.18.9
PayLoad received on I/O interface
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER send(1), send-10(2), setupconn(3), stop(4), clearTxStats(5), clearRxStats(6)  

cellTestRxPduCount 3.1.1751.2.18.18.10
Valid cells received (Input Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cellTestTxPduCount 3.1.1751.2.18.18.11
Valid cells transmitted (Output Billing Count)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cellTestMismatchPduCount 3.1.1751.2.18.18.12
Number of times Rx payload mismatched with Tx payload.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cellTestStatus 3.1.1751.2.18.18.13
Indicates whether a cellTest test is in progress or not.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER running(1), not-running(2)  

cellTestVUNIB 3.1.1751.2.18.18.14
VUNI id for testing cell transfer to an I/O card. This field is valid only for ATM interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

sysInfoTxOneCellTotal 3.1.1751.2.18.19.1
Total amount of cells within the transmit one cell pool.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysInfoTxOneCellUsed 3.1.1751.2.18.19.2
Amount of cells currently being used within the transmit one cell pool.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysInfoTxOneCellHigh 3.1.1751.2.18.19.3
High-water mark of cells used within the transmit one cell pool.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysInfoRxOneCellTotal 3.1.1751.2.18.19.4
Total amount of cells within the receive one cell pool.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysInfoRxOneCellUsed 3.1.1751.2.18.19.5
Amount of cells currently being used within the receive one cell pool.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysInfoRxOneCellHigh 3.1.1751.2.18.19.6
High-water mark of cells used within the receive one cell pool.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysInfoRxMultiCellTotal 3.1.1751.2.18.19.7
Total amount of multi-cells within the receive multi-cell pool.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysInfoRxMultiCellUsed 3.1.1751.2.18.19.8
Amount of multi-cells currently being used within the receive multi-cell pool.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysInfoRxMultiCellHigh 3.1.1751.2.18.19.9
High-water mark of multi-cells used within the receive multi-cell pool.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysInfoMsgPoolTotal 3.1.1751.2.18.19.10
Total amount of messages within the message pool.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysInfoMsgPoolUsed 3.1.1751.2.18.19.11
Amount of messages currently being used within the message pool.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysInfoMsgPoolHigh 3.1.1751.2.18.19.12
High-water mark of messages used within the message pool.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysInfoDiscFreeKBytes 3.1.1751.2.18.19.13
Amount of disc free space available in KB's.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysInfoCpuUtilization1 3.1.1751.2.18.19.14
xx.yy% - cpuUtilization1 is the xx part of it.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..99  

sysInfoCpuUtilization2 3.1.1751.2.18.19.15
xx.yy% - cpuUtilization2 is the yy part of it.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..99  

sysInfoSysUptime 3.1.1751.2.18.19.16
Amount of time cpu has been up in seconds.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysInfoBadCellRx 3.1.1751.2.18.19.17
The number of bad cells (BIP16) received so far.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysInfoMisaligned 3.1.1751.2.18.19.18
The number of misaligned cells received so far.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysInfoClockAErr 3.1.1751.2.18.19.19
Value is 1, TRUE, if the clock on backplane A is errored, otherwise, the value is 0, FALSE.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

sysInfoClockBErr 3.1.1751.2.18.19.20
Value is 1, TRUE, if the clock on backplane B is errored, otherwise, the value is 0, FALSE.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

sysInfoBIPAErr 3.1.1751.2.18.19.21
Value is 1, TRUE, if the cell circuit on backplane A is errored, otherwise, the value is 0, FALSE.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

sysInfoBIPBErr 3.1.1751.2.18.19.22
Value is 1, TRUE, if the cell circuit on backplane B is errored, otherwise, the value is 0, FALSE.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

sysInfoDiscTotalKBytes 3.1.1751.2.18.19.23
Amount of disc space available in KB's.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysInfoRAMFreeKBytes 3.1.1751.2.18.19.24
Amount of RAM memory available for use in KB's.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysInfoRAMTotalKBytes 3.1.1751.2.18.19.25
Amount of RAM memory available on cpu card in KB's.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

msgPoolViewTable 3.1.1751.2.18.19.26
Table of Msg Pools In the System, Used only for diagnostic purposes
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MsgPoolViewEntry

primaryCpuHwType 3.1.1751.2.18.19.27
Indicates the hardware version type of the primary CPU. version1: 150MHz Saturn13 board supporting 8MB-64MB Memory. version2: 200MHz Saturn15 board supporting 64MB-256MB Memory.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notKnown(1), version1(2), version2(3)  

secondaryCpuHwType 3.1.1751.2.18.19.28
Indicates the hardware version type of the secondary CPU. version1: 150MHz Saturn13 board supporting 8MB-64MB Memory. version2: 200MHz Saturn15 board supporting 64MB-256MB Memory.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notKnown(1), version1(2), version2(3)  

msgPoolViewEntry 3.1.1751.2.18.19.26.1
Row definition of Msg Pool Table
Status: current Access: not-accessible
OBJECT-TYPE    
  MsgPoolViewEntry  

msgPoolViewIndex 3.1.1751.2.18.19.26.1.1
It is the index of the MsgPool array for which the information is requested. Information about Msgs Which are not there in the free pool is returned.A msg is said to be out of the free pool by comparing the signature. The limit being the max number of msgs allowed on the system
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

msgPoolViewTskId 3.1.1751.2.18.19.26.1.2
Task Id of the Sender of the Particular Msg, This will give the integer value, has to be converted to hex for comparison
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

msgPoolViewTskName 3.1.1751.2.18.19.26.1.3
Task Name of the Sender of the Particular Msg
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(20)  

msgPoolViewMsgCmd 3.1.1751.2.18.19.26.1.4
msgCmd being sent by the sending Task
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysInfoDiskCheck 3.1.1751.2.18.19.29
Indicates the checking status of the disk in CPU card.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), error(2)  

switchAlarmStatus 3.1.1751.2.18.19.30
Current status of the alarm on the switch. notAvailable - The alarm status could not be retreived. none - No alarm is present. minor, major, critical - An alarm of the enumerated type is present
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notAvailable(1), none(2), minor(3), major(4), critical(5)  

arp1Table 3.1.1751.2.18.20.1
Table of ARP cache data.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Arp1Entry

arp1Entry 3.1.1751.2.18.20.1.1
Row definition for ARP cache.
Status: current Access: not-accessible
OBJECT-TYPE    
  Arp1Entry  

arp1CardSlot 3.1.1751.2.18.20.1.1.1
Slot ethernet card is in.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..16  

arp1BridgeGroupNum 3.1.1751.2.18.20.1.1.2
Bridge Group the entry belongs to.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..999  

arp1IpAddress 3.1.1751.2.18.20.1.1.3
Entry IP address.
Status: current Access: not-accessible
OBJECT-TYPE    
  IpAddress  

arp1PhysicalAddr 3.1.1751.2.18.20.1.1.4
Entry physical address.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

arp1EntryAge 3.1.1751.2.18.20.1.1.5
Age of cache entry.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

arp2Table 3.1.1751.2.18.20.2
Table of ARP cache data.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Arp2Entry

arp2Entry 3.1.1751.2.18.20.2.1
Row definition for ARP cache.
Status: current Access: not-accessible
OBJECT-TYPE    
  Arp2Entry  

arp2CardSlot 3.1.1751.2.18.20.2.1.1
Slot ethernet card is in.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..16  

arp2BridgeGroupNum 3.1.1751.2.18.20.2.1.2
Bridge Group the entry belongs to.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..999  

arp2PhysicalAddr 3.1.1751.2.18.20.2.1.3
Entry physical address.
Status: current Access: not-accessible
OBJECT-TYPE    
  OCTET STRING Size(6)  

arp2IpAddress 3.1.1751.2.18.20.2.1.4
Entry IP address.
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

arp2EntryAge 3.1.1751.2.18.20.2.1.5
Age of cache entry.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bridgeCacheTable 3.1.1751.2.18.20.3
Table of bridge cache data.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    BridgeCacheEntry

bridgeCacheEntry 3.1.1751.2.18.20.3.1
Row definition for bridge cache.
Status: current Access: not-accessible
OBJECT-TYPE    
  BridgeCacheEntry  

bridgeCacheCardSlot 3.1.1751.2.18.20.3.1.1
Slot ethernet card is in.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..16  

bridgeCacheBridgeGroupNum 3.1.1751.2.18.20.3.1.2
Bridge Group the entry belongs to.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..999  

bridgeCachePhysicalAddr 3.1.1751.2.18.20.3.1.3
Entry physical address.
Status: current Access: not-accessible
OBJECT-TYPE    
  OCTET STRING Size(6)  

bridgeCacheType 3.1.1751.2.18.20.3.1.4
Type of Entry.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER learned(1), permanent(2), policy(3)  

bridgeCacheSourcePort 3.1.1751.2.18.20.3.1.5
Port entry was obtained from.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..75  

bridgeCacheEntryAge 3.1.1751.2.18.20.3.1.6
Age of cache entry.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

alarmStatusInputBitmap 3.1.1751.2.18.21.1
Remote status from external device. bit = 0 closed, bit = 1 open, LSB 15 bits represent 15 external inputs. MSB bit 15 is always 0.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(2)  

alarmStatusOutputBitmap 3.1.1751.2.18.21.2
Control output for alarm card. bit = 0 deactivated, bit = 1 activated, LSB 4 bits represent 4 external outputs. Bit 0 through bit 3 is output 1 through 4 Control output 4 will be activated upon power failure.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

alarmSeverityLevelBitmap 3.1.1751.2.18.21.3
Alarm severity level. bit = 0 noAlarm, bit = 1 Alarm present, LSB 3 bits represent severity levels. bit 0 = Minor Alarm, bit 1 = Major Alarm, bit 2 = Critical Alarm.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

alarmAcoStatusBitmap 3.1.1751.2.18.21.4
Audio alarm status. bit = 0 No alarm cutoff, bit = 1 Alarm cutoff, LSB 3 bits represent audio alarms. bit 0 = Local alarm cutoff, bit 1 = remote alarm cutoff, bit 2 = composite alarm cutoff status.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1)  

oamTest 3.1.1751.2.18.22.1
OBJECT IDENTIFIER    

oamTestIfB 3.1.1751.2.18.22.1.1
Interface index used for starting loopback test. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: read-write
OBJECT-TYPE    
  IntfIndex  

oamTestVpiB 3.1.1751.2.18.22.1.2
VPI value under testing for oam loopback test. Valid range is a number between 0 and 4095.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

oamTestVciB 3.1.1751.2.18.22.1.3
VCI value under testing for oam loopback test. Valid range is a number between 0 and 65535.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

oamTestStatus 3.1.1751.2.18.22.1.4
Inidcates the current status of oam test.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER not-running(1), running(2), successful(3), failure(4), timedout(5), waiting-for-response(6)  

oamTestAction 3.1.1751.2.18.22.1.5
Test action to be performed.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER sendLoopback(1), sendContinuously(2), stopTest(3), resetTxCount(4), resetRxCount(5), resetMismatchCount(6)  

oamTestTxCount 3.1.1751.2.18.22.1.6
Valid cells transmitted.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

oamTestRxCount 3.1.1751.2.18.22.1.7
Valid cells received.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

oamTestMismatchCount 3.1.1751.2.18.22.1.8
Number of times Rx correlation tag is mismatched with the Tx correlation tag.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

oamTestLocationID 3.1.1751.2.18.22.1.9
Location ID of the ATM Node where the loopback is to occur.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(16)  

oamTestLoopbackType 3.1.1751.2.18.22.1.10
OAM Loopback type. Determines whether to send ete or segment loopback cell, and the value of location Id field in the cell. Only for specific-location value, user specified locationId field value taken into account.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER end-to-end(1), segment-endpoint(2), next-connection-point(3), specific-location(4)  

oamActDeactTable 3.1.1751.2.18.22.2
Table of oam activate and deactivate functions
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OamActDeactEntry

oamActDeactEntry 3.1.1751.2.18.22.2.1
Row definition of oam activate and deactivate
Status: current Access: not-accessible
OBJECT-TYPE    
  OamActDeactEntry  

oamActDeactIfB 3.1.1751.2.18.22.2.1.1
Interface index for an OAM CC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

oamActDeactVpiB 3.1.1751.2.18.22.2.1.2
VPI value for an oam CC connection. Valid range is a number between 0 and 4095.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..4095  

oamActDeactVciB 3.1.1751.2.18.22.2.1.3
VCI value for oam CC connection. Valid range is a number between 0 and 65535.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..65535  

oamActDeactFuncType 3.1.1751.2.18.22.2.1.4
OAM Function type represents the OAM flow for activation or deactivattion for this connection. the possible function types activated in one connection are : fpm-and-br : forward performance monitoring/backward reporting fpm-only : forward performance monitoring continuity-check : continuity check pmbr-and-cc : forward performance monitoring/backward reporting and continuity check pm-and-cc : forward performance monitoring and continuity check
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER fpm-and-br(1), fpm-only(2), continuity-check(3), pmbr-and-cc(4), pm-and-cc(5)  

oamActDeactDirFlow 3.1.1751.2.18.22.2.1.5
The direction in which cells will be transmitted.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER towards-far-end(1), towards-near-end(2), both-way(3)  

oamActDeactFlowType 3.1.1751.2.18.22.2.1.6
Flow Type.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER end-to-end(1), segment(2)  

oamActDeactBlkSizeAB 3.1.1751.2.18.22.2.1.7
Block Size A-B represents the size of the block of user cells taken into consideration for performance monitoring in A-B direction.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER size128(1), size256(2), size512(3), size1024(4), size4096(5), size8192(6), size16384(7), size32768(8), size2048(9)  

oamActDeactBlkSizeBA 3.1.1751.2.18.22.2.1.8
Block Size A-B is the size of the block of user cells taken into consideration for performance monitoring in B-A direction.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER size128(1), size256(2), size512(3), size1024(4), size4096(5), size8192(6), size16384(7), size32768(8), size2048(9)  

oamActDeactStsSrcPointEteCC 3.1.1751.2.18.22.2.1.9
Source point showed in the status portion displays the current status of Activation or Deactivation request for the source point
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER activated(1), deactivated(2), waitActConfirm(3), waitDeactConfirm(4)  

oamActDeactStsSnkPointEteCC 3.1.1751.2.18.22.2.1.10
Sink point showed in the status portion displays the current status of Activation or Deactivation request for the sink point
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER activated(1), deactivated(2), waitActConfirm(3), waitDeactConfirm(4)  

oamActDeactRsltPrevReq 3.1.1751.2.18.22.2.1.11
Cause of Failure shows the reasons of failure of the last activation request on this connection form the local user.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER denied(1), timedout(2), locResrcUnavl(3), oamUnsupported(4), reqCancelled(5), funcNotImplemented(6), none(7), successful(8)  

oamActDeactRowStatus 3.1.1751.2.18.22.2.1.12
row status
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

oamActDeactStsSrcPointEtePM 3.1.1751.2.18.22.2.1.13
Source point showed in the status portion displays the current status of Activation or Deactivation request for the source point
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER activated(1), deactivated(2), waitActConfirm(3), waitDeactConfirm(4)  

oamActDeactStsSnkPointEtePM 3.1.1751.2.18.22.2.1.14
Sink point showed in the status portion displays the current status of Activation or Deactivation request for the sink point
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER activated(1), deactivated(2), waitActConfirm(3), waitDeactConfirm(4)  

oamActDeactStsSrcPointEtePMBR 3.1.1751.2.18.22.2.1.15
Source point showed in the status portion displays the current status of Activation or Deactivation request for the source point
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER activated(1), deactivated(2), waitActConfirm(3), waitDeactConfirm(4)  

oamActDeactStsSnkPointEtePMBR 3.1.1751.2.18.22.2.1.16
Sink point showed in the status portion displays the current status of Activation or Deactivation request for the sink point
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER activated(1), deactivated(2), waitActConfirm(3), waitDeactConfirm(4)  

oamActDeactBRBlockError 3.1.1751.2.18.22.2.1.17
Backware reporting Block error for PM connection. Valid range is a number between 0 and 32768.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..32768  

oamActDeactBRLostInsertedCell 3.1.1751.2.18.22.2.1.18
Backware reporting lost inserted cell for PM connection. Valid range is a number between 0 and 32768.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..32768  

oamActDeactBRMisInsertedCell 3.1.1751.2.18.22.2.1.19
Backware reporting misinserted cell for PM connection. Valid range is a number between 0 and 32768.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..32768  

oamActDeactStsSrcPointSegPM 3.1.1751.2.18.22.2.1.20
Source point showed in the status portion displays the current status of Activation or Deactivation request for the source point
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER activated(1), deactivated(2), waitActConfirm(3), waitDeactConfirm(4)  

oamActDeactStsSnkPointSegPM 3.1.1751.2.18.22.2.1.21
Sink point showed in the status portion displays the current status of Activation or Deactivation request for the sink point
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER activated(1), deactivated(2), waitActConfirm(3), waitDeactConfirm(4)  

oamActDeactStsSrcPointSegPMBR 3.1.1751.2.18.22.2.1.22
Source point showed in the status portion displays the current status of Activation or Deactivation request for the source point
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER activated(1), deactivated(2), waitActConfirm(3), waitDeactConfirm(4)  

oamActDeactStsSnkPointSegPMBR 3.1.1751.2.18.22.2.1.23
Sink point showed in the status portion displays the current status of Activation or Deactivation request for the sink point
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER activated(1), deactivated(2), waitActConfirm(3), waitDeactConfirm(4)  

oamActDeactStsSrcPointSegCC 3.1.1751.2.18.22.2.1.24
Source point showed in the status portion displays the current status of Activation or Deactivation request for the source point
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER activated(1), deactivated(2), waitActConfirm(3), waitDeactConfirm(4)  

oamActDeactStsSnkPointSegCC 3.1.1751.2.18.22.2.1.25
Sink point showed in the status portion displays the current status of Activation or Deactivation request for the sink point
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER activated(1), deactivated(2), waitActConfirm(3), waitDeactConfirm(4)  

oamLoopbackTable 3.1.1751.2.18.22.3
Table of oam loopback functions
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OamLoopbackEntry

oamLoopbackEntry 3.1.1751.2.18.22.3.1
Row definition of oam loop back
Status: current Access: not-accessible
OBJECT-TYPE    
  OamLoopbackEntry  

oamLpbkIfB 3.1.1751.2.18.22.3.1.1
Interface index used for starting loopback test. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

oamLpbkVpiB 3.1.1751.2.18.22.3.1.2
VPI value under testing for oam loopback test. Valid range is a number between 0 and 4095.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..4095  

oamLpbkVciB 3.1.1751.2.18.22.3.1.3
VCI value under testing for oam loopback test. Valid range is a number between 0 and 65535.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..65535  

oamLoopbackType 3.1.1751.2.18.22.3.1.4
OAM Loopback type. Determines whether to send ete or segment loopback cell, and the value of location Id field in the cell. Only for specific-location value, user specified locationId field value taken into account.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER end-to-end(1), segment-endpoint(2), next-connection-point(3), specific-location(4)  

oamLpbkLocationID 3.1.1751.2.18.22.3.1.5
Location ID of the ATM Node where the loopback is to occur.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(16)  

oamLpbkAction 3.1.1751.2.18.22.3.1.6
Test action to be performed. endLoopbackContinuously is not used.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER sendLoopbackOnce(1), sendLoopbackContinuously(2), stopTest(3), resetStats(4)  

oamLpbkStatus 3.1.1751.2.18.22.3.1.7
Inidcates the current status of oam test.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER inactive(1), waiting-for-response(2), successful(3), timedout(4)  

oamLpbkTxCount 3.1.1751.2.18.22.3.1.8
Valid cells transmitted.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

oamLpbkRxCount 3.1.1751.2.18.22.3.1.9
Valid cells received.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

oamLpbkMismatchCount 3.1.1751.2.18.22.3.1.10
Number of times Rx correlation tag is mismatched with the Tx correlation tag.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

oamLpbkTimeout 3.1.1751.2.18.22.3.1.11
number of time out
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprRouterConfigTable 3.1.1751.2.18.24.1
Table of Vipr Router Instance Information
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ViprRouterConfigEntry

viprRouterConfigEntry 3.1.1751.2.18.24.1.1
definition for VIPR Route instance attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  ViprRouterConfigEntry  

viprSlot 3.1.1751.2.18.24.1.1.1
The slot number of the Virtual Router card (SS)
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

viprRouterId 3.1.1751.2.18.24.1.1.2
A unique Id for the Router Instance in a router card
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..6  

viprRouterName 3.1.1751.2.18.24.1.1.3
The ASCII name of the Router Instance
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(32)  

viprRouterNoOfInterfaces 3.1.1751.2.18.24.1.1.4
This variable describes the no of interfaces defined in the Router Instance
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..99  

viprRouterNoOfRoutes 3.1.1751.2.18.24.1.1.5
This variable describes the no of static routes defined in the Router Instance
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..1024  

viprRouterAdminStatus 3.1.1751.2.18.24.1.1.6
This variable represents the various X.731 states the Router state machine can take Administartively
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2)  

viprRouterOperStatus 3.1.1751.2.18.24.1.1.7
This variable represents the various X.731 states the Router state machine can take operationally
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2), unlocked-Init(3), unlocked-Disable(4), locked-Shutting(5)  

viprRouterInitTmr 3.1.1751.2.18.24.1.1.8
This variable describes the waiting period in the locked-Init state before moving onto locked-Diable state.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

viprRouterDisabWarnTmr 3.1.1751.2.18.24.1.1.9
This variable describes the periodicity in which the error messages are to be flashed when the system is in unlocked-Disable state.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

viprRouterShutDwnWarnTmr 3.1.1751.2.18.24.1.1.10
This variable describes the periodicity in which the error messages are to be flashed when the system is in locked-Shutting state.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

viprRouterDisableWarning 3.1.1751.2.18.24.1.1.11
This variable when disabled will mask all the warning messages.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

viprRouterDisableReason 3.1.1751.2.18.24.1.1.12
This variable describes the reason why the Router in the unlocked-Disabled state.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), manual(2), automatic(3)  

viprRouterRowStatus 3.1.1751.2.18.24.1.1.13
row status
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

viprIntfConfigTable 3.1.1751.2.18.24.2
Table of Vipr Interface Config Information
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ViprIntfConfigEntry

viprIntfConfigEntry 3.1.1751.2.18.24.2.1
definition for VIPR interface attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  ViprIntfConfigEntry  

viprIntfId 3.1.1751.2.18.24.2.1.1
A unique Id for the Interface in a router instance
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..16  

viprIntfIPAddress 3.1.1751.2.18.24.2.1.2
The IP address of the entrprise network to which the interface is attached to
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

viprIntfIPNetMask 3.1.1751.2.18.24.2.1.3
The IP Subnet Mask of the entrprise network to which the interface is attached to
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

viprIntfAdminStatus 3.1.1751.2.18.24.2.1.4
This variable represents the various X.731 states the Interfce statemachine can take Administratively
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2)  

viprIntfOperStatus 3.1.1751.2.18.24.2.1.5
This variable represents the various X.731 states the Interfce statemachine can take operationally
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2), unlocked-Init(3), unlocked-Disable(4), locked-Shutting(5)  

viprIntfInitTmr 3.1.1751.2.18.24.2.1.6
This variable describes the waiting period in the locked-Init state before moving onto locked-Diable state.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

viprIntfDisabWarnTmr 3.1.1751.2.18.24.2.1.7
This variable describes the periodicity in which the error messages are to be flashed when the system is in unlocked-Disable state.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

viprIntfShutDwnWarnTmr 3.1.1751.2.18.24.2.1.8
This variable describes the periodicity in which the error messages are to be flashed when the system is in locked-Shutting state.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

viprIntfDisableWarning 3.1.1751.2.18.24.2.1.9
This variable when disabled will mask all the Disable warning messages.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

viprIntfDisableReason 3.1.1751.2.18.24.2.1.10
This variable describes the reason why the Interface in the unlocked-Disabled state.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), intfDisabled(2), routDisabled(3)  

viprIntfRipVersion 3.1.1751.2.18.24.2.1.11
This specifies the version of RIP that interface supports.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER version-1(1), version-2(2)  

viprIntfRipMode 3.1.1751.2.18.24.2.1.12
This specifies the mode in which RIP protocol runs.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), active(2), passive(3)  

viprIntfRowStatus 3.1.1751.2.18.24.2.1.13
row status
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

viprIntfRipLineType 3.1.1751.2.18.24.2.1.14
This specifies the line type when the RIP version is 2. When the RIP version is 1, the RIP line type will be set to broadcast(1).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER broadcast(1), multicast(2)  

viprIntfAuthPasswd 3.1.1751.2.18.24.2.1.15
The authentication password for RIP version 2
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(16)  

viprSubChnlConfigTable 3.1.1751.2.18.24.3
Table of Vipr Sub Channel Config Information
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ViprSubChnlConfigEntry

viprSubChnlConfigEntry 3.1.1751.2.18.24.3.1
definition for VIPR sub channel attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  ViprSubChnlConfigEntry  

viprSubChnlId 3.1.1751.2.18.24.3.1.1
A unique Id for the sub channel in the interface
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..3  

viprSubChnlIntfIndex 3.1.1751.2.18.24.3.1.2
The Slot Port Channel to which the IP Packet to be forwarded when the TOS specified in the incoming IP packet is matched to the TosValue, TosMask pair
Status: current Access: read-write
OBJECT-TYPE    
  IntfIndex  

viprSubChnlTrafficType 3.1.1751.2.18.24.3.1.3
The type of interface configured on the SSPPCCC, viprSubChnlIntfIndex
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER atm(1), fR(2), bridge(3), routing(4), inband(5)  

viprSubChnlLlcEncapType 3.1.1751.2.18.24.3.1.4
The encapsulation technique used in making IP packet to ATM cell
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER vc(1), llcSnap(2)  

viprSubChnlMacEncapType 3.1.1751.2.18.24.3.1.5
The encapsulation technique used in making IP packet to ATM cell
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER macHdr(1), noMacHdr(2)  

viprSubChnlTosFeature 3.1.1751.2.18.24.3.1.6
Allow the user to set the TOS values or not
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

viprSubChnlTosValue 3.1.1751.2.18.24.3.1.7
The type of service specified in IP packet masked with viprSubChnlTosMask has to be equal to this value in order to have the IP packets getting forwarded in this sub channel
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

viprSubChnlTosMask 3.1.1751.2.18.24.3.1.8
The Type of Service mask
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

viprSubChnlVpiDlci 3.1.1751.2.18.24.3.1.9
The VPI/DLCI value of the connection
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

viprSubChnlVci 3.1.1751.2.18.24.3.1.10
The VCI value of the connection
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..4096  

viprSubChnlSarType 3.1.1751.2.18.24.3.1.11
The SAR Type supported for the connection
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER aal5(1)  

viprSubChnlServiceType 3.1.1751.2.18.24.3.1.12
The Service types that are supported
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER gold(1), silver(2), bronze(3)  

viprSubChnlFwdErrCorrection 3.1.1751.2.18.24.3.1.13
The Forward error correction to be used
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), eighthRate(2), quarterRate(3), halfRate(4), autoHiQ(5), auto(6), autoLoQ(7)  

viprSubChnlInterworkingType 3.1.1751.2.18.24.3.1.14
The Encapsulation type used for Frame relay subchannels
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER frf8(1)  

viprSubChnlFrameSize 3.1.1751.2.18.24.3.1.15
The value of this object is the size in octets of the largest frame relay information field for this PVC in the ingress direction (out of the frame relay UNI).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

viprSubChnlComBurstSize 3.1.1751.2.18.24.3.1.16
The value of this object is equal to the committed burst size (Bc) parameter (measured in bits) for this PVC in the ingress direction (into the frame relay UNI).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

viprSubChnlExcessBurstSize 3.1.1751.2.18.24.3.1.17
The value of this object is equal to the excess burst size (Be) parameter (measured in bits) for this PVC in the ingress direction (into the frame relay UNI).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

viprSubChnlCommitedInfoRate 3.1.1751.2.18.24.3.1.18
The value of this object is equal to the committed information rate (CIR) parameter (measured in bits per second) for this PVC in the ingress direction (into the frame relay UNI).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

viprSubChnlTimeInterval 3.1.1751.2.18.24.3.1.19
The time interval over which CIR and the burst sizes (Bc and Be) are measured in the A2B direction. The unit is milliseconds.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 64..4000  

viprSubChnlAtmPeakCellRate 3.1.1751.2.18.24.3.1.20
Peak cell rate, in cells per second, this will reflect the frame relay parameters in atm terms.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

viprSubChnlAtmSustainedCellRate 3.1.1751.2.18.24.3.1.21
Sustained cell rate, in cells per second, this will reflect the frame relay parameters in atm terms.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

viprSubChnlAtmMaxBurstSize 3.1.1751.2.18.24.3.1.22
Maximum burst size, in cells, this will reflect the frame relay parameters in atm terms.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

viprSubChnlFrPeakCellRate 3.1.1751.2.18.24.3.1.23
Peak cell rate, in cells per second, this will reflect the frame relay parameters in atm terms.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprSubChnlFrSustainedCellRate 3.1.1751.2.18.24.3.1.24
Sustained cell rate, in cells per second, this will reflect the frame relay parameters in atm terms.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprSubChnlFrMaxBurstSize 3.1.1751.2.18.24.3.1.25
Maximum burst size, in cells, this will reflect the frame relay parameters in atm terms.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprSubChnlFlowType 3.1.1751.2.18.24.3.1.26
The type of flow
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER duplex(1)  

viprSubChnlAdminStatus 3.1.1751.2.18.24.3.1.27
This variable represents the various X.731 states the Sub Channel state machine can take Administartively
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2)  

viprSubChnlOperStatus 3.1.1751.2.18.24.3.1.28
This variable represents the various X.731 states the Sub Channel state machine can take Operationally
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2), unlocked-Init(3), unlocked-Disable(4), locked-Shutting(5)  

viprSubChnlInitTmr 3.1.1751.2.18.24.3.1.29
This variable describes the waiting period in the locked-Init state before moving onto locked-Diable state.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

viprSubChnlDisabWarnTmr 3.1.1751.2.18.24.3.1.30
This variable describes the periodicity in which the error messages are to be flashed when the system is in unlocked-Disable state.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

viprSubChnlShutDwnWarnTmr 3.1.1751.2.18.24.3.1.31
This variable describes the periodicity in which the error messages are to be flashed when the system is in locked-Shutting state.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

viprSubChnlDisableWarning 3.1.1751.2.18.24.3.1.32
This variable when disabled will mask all the Disable warning messages.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

viprSubChnlDisableReason 3.1.1751.2.18.24.3.1.33
This variable describes the reason why the SubChnl in the unlocked-Disabled state.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), intfDisabled(2), routDisabled(3)  

viprSubChnlRowStatus 3.1.1751.2.18.24.3.1.34
row status
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

viprSubChnlImIpAddr 3.1.1751.2.18.24.3.1.35
inband management IpAddr
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

viprSubChnlImMask 3.1.1751.2.18.24.3.1.36
inband management Mask
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

viprSubChnlViB 3.1.1751.2.18.24.3.1.37
The viB value of the connection
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..4096  

viprSubChnlVUNIB 3.1.1751.2.18.24.3.1.38
The VUNIB value of the connection
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

viprSubChnlTrafficShaping 3.1.1751.2.18.24.3.1.39
Traffic Shaping Support in the A2B direction for outgoing ATM connections.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

viprSubChnlAtmOamStatus 3.1.1751.2.18.24.3.1.40
Indicates the OAM monitoring status. The 3 possible states are: Unsupp: No monitoring enabled. End-Pt: A side is only an end point, therefore it will respond to AIS/RDI. End-Seg-Pt: Connection endPoint that is also a segment endPoint.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unsupp(1), end-Pt(2), end-Seg-Pt(3)  

viprRouteConfigTable 3.1.1751.2.18.24.4
Table of Vipr static route Config Information
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ViprRouteConfigEntry

viprRouteConfigEntry 3.1.1751.2.18.24.4.1
Definition for Vipr static route attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  ViprRouteConfigEntry  

viprRouteId 3.1.1751.2.18.24.4.1.1
The unique Id to the routing table entry
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..1024  

viprRouteIPAddress 3.1.1751.2.18.24.4.1.2
The IP address of the host/network in the route entry
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

viprRouteIPNetMask 3.1.1751.2.18.24.4.1.3
The IP Subnet Mask for the route entry to identify whether the route entry is a host or network
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

viprRouteDestAddress 3.1.1751.2.18.24.4.1.4
The IP address of the host/network in the route entry
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

viprRouteGatewayAddress 3.1.1751.2.18.24.4.1.5
The IP address of the Gateway
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

viprRouteServiceType 3.1.1751.2.18.24.4.1.6
The Service types that are supported
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER gold(1), silver(2), bronze(3)  

viprRouteMetric 3.1.1751.2.18.24.4.1.7
A scalar value for user-supplied static route metric values.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

viprRouteAdminStatus 3.1.1751.2.18.24.4.1.8
This variable represents the various X.731 states the Route state machine can take Administratively
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2)  

viprRouteOperStatus 3.1.1751.2.18.24.4.1.9
This variable represents the various X.731 states the Route state machine can take Operationally
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER outOfService(1), inService(2), unlocked-Init(3), unlocked-Disable(4), locked-Shutting(5)  

viprRouteInitTmr 3.1.1751.2.18.24.4.1.10
This variable describes the waiting period in the locked-Init state before moving onto locked-Diable state.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

viprRouteDisabWarnTmr 3.1.1751.2.18.24.4.1.11
This variable describes the periodicity in which the error messages are to be flashed when the system is in unlocked-Disable state.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

viprRouteShutDwnWarnTmr 3.1.1751.2.18.24.4.1.12
This variable describes the periodicity in which the error messages are to be flashed when the system is in locked-Shutting state.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

viprRouteDisableWarning 3.1.1751.2.18.24.4.1.13
This variable when disabled will mask all the Disable warning messages.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

viprRouteDisableReason 3.1.1751.2.18.24.4.1.14
This variable describes the reason why the Route in the unlocked-Disabled state.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), intfDisabled(2), routDisabled(3)  

viprRouteRowStatus 3.1.1751.2.18.24.4.1.15
row status
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

viprRouteDestMask 3.1.1751.2.18.24.4.1.16
The IP Mask of the host/network in the route entry
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

viprRoutingConfigTable 3.1.1751.2.18.24.5
Table of Vipr routes Config Information
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ViprRoutingConfigEntry

viprRoutingConfigEntry 3.1.1751.2.18.24.5.1
Definition for Vipr route attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  ViprRoutingConfigEntry  

viprRoutingCommand 3.1.1751.2.18.24.5.1.1
The Routing table request command Set to start to initiate the caching of first 15 entries Set to more to initiate the caching of next 15 entries Set to abort to reset the counter in I/O card Set to retrieve in order to get the entries
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER start(1), more(2), abort(3), retrieve(4)  

viprRoutingIPAddress 3.1.1751.2.18.24.5.1.2
The IP address of the host/network in the route entry
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

viprRoutingIPNetMask 3.1.1751.2.18.24.5.1.3
The IP Subnet Mask for the route entry to identify whether the route entry is a host or network
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

viprRoutingDestAddress 3.1.1751.2.18.24.5.1.4
The IP address of the host/network in the route entry
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

viprRoutingGatewayAddress 3.1.1751.2.18.24.5.1.5
The IP address of the Gateway
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

viprRoutingServiceType 3.1.1751.2.18.24.5.1.6
The Service types that are supported
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER gold(1), silver(2), bronze(3)  

viprRoutingType 3.1.1751.2.18.24.5.1.7
Route types supported by the RS Card.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER stat(1), rip(2), ospf(3), intf(4)  

viprRoutingMetric 3.1.1751.2.18.24.5.1.8
The Path cost
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprRoutingDestMask 3.1.1751.2.18.24.5.1.9
The IP address Mask of the host/network in the route entry
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

viprRoutingAge 3.1.1751.2.18.24.5.1.10
Age of the routing entry
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprRoutingIndex 3.1.1751.2.18.24.5.1.11
Index to the routing entry
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

viprArpConfigTable 3.1.1751.2.18.24.6
Table of Vipr Arp Table Information
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ViprArpConfigEntry

viprArpConfigEntry 3.1.1751.2.18.24.6.1
Definition for Vipr Arp Table attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  ViprArpConfigEntry  

viprArpCommand 3.1.1751.2.18.24.6.1.1
The ARP table request command Set to start to initiate the caching of first 15 entries Set to more to initiate the caching of next 15 entries Set to abort to reset the counter in I/O card Set to retrieve in order to get the entries
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER start(1), more(2), abort(3), retrieve(4)  

viprArpIPAddress 3.1.1751.2.18.24.6.1.2
The IP address of the host/network
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

viprArpHwAddress 3.1.1751.2.18.24.6.1.3
The hardware address of the host/network
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

viprArpEntryAge 3.1.1751.2.18.24.6.1.4
Age of cache entry.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprArpInterfaceIPAddress 3.1.1751.2.18.24.6.1.5
The Interface IP address through which it is learned
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

viprArpInterfaceIPMask 3.1.1751.2.18.24.6.1.6
The Interface IP address Mask
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

viprArpInterfaceServiceType 3.1.1751.2.18.24.6.1.7
The Service type of the interface through which the ARP table is learned
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER gold(1), silver(2), bronze(3)  

viprArpIndex 3.1.1751.2.18.24.6.1.8
The Index to the Arp table
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

viprPingConfigTable 3.1.1751.2.18.24.7
Table of Vipr Ping Table Information
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ViprPingConfigEntry

viprPingConfigEntry 3.1.1751.2.18.24.7.1
Definition for Vipr Ping Table attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  ViprPingConfigEntry  

ipAddr 3.1.1751.2.18.24.7.1.1
The IP address of the host/network to be echoed
Status: current Access: not-accessible
OBJECT-TYPE    
  IpAddress  

pingStatus 3.1.1751.2.18.24.7.1.2
The response value - Alive/Not Alive
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER alive(1), not-Alive(2)  

viprRipConfigTable 3.1.1751.2.18.24.8
Table of Vipr Rip Update Interval for each card
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ViprRipConfigEntry

viprRipConfigEntry 3.1.1751.2.18.24.8.1
Definition of Rip Update attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  ViprRipConfigEntry  

viprRipUpdateInt 3.1.1751.2.18.24.8.1.1
This variable represents the Rip Update Interval used by the RIP protocol to transmit packets. The unit is in seconds. The default is 30 seconds and user can change it to 8 or 16 seconds for a route server card. The value will apply to all VPN's in a route server card. But different route server cards in different slots can have separate values for Rip Update Interval
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER lowUpdateInt(8), mediumUpdateInt(16), normalUpdateInt(30)  

viprVpnStatsTable 3.1.1751.2.18.10.9
Statistics collected per vpn based
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ViprVpnStatsEntry

viprVpnStatsEntry 3.1.1751.2.18.10.9.1
Statistics collected per vpn based
Status: current Access: not-accessible
OBJECT-TYPE    
  ViprVpnStatsEntry  

viprVpnStatsTimer 3.1.1751.2.18.10.9.1.1
A timeout value in which the RS Module must reply to statistics requests.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprVpnStatsIcmpOutEchoRPs 3.1.1751.2.18.10.9.1.2
Echo Reply
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprVpnStatsIcmpOutDestURs 3.1.1751.2.18.10.9.1.3
Destination unreachable
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprVpnStatsIcmpOutSrcQ 3.1.1751.2.18.10.9.1.4
Source Quenches
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprVpnStatsIcmpOutRedirects 3.1.1751.2.18.10.9.1.5
Redirect message type
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprVpnStatsIcmpOutEchoRQs 3.1.1751.2.18.10.9.1.6
Echo Requests
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprVpnStatsIcmpOutTimeXs 3.1.1751.2.18.10.9.1.7
Time exceeded
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprVpnStatsIcmpOutParamps 3.1.1751.2.18.10.9.1.8
Parameter problem
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprVpnStatsIcmpOutTimeRQs 3.1.1751.2.18.10.9.1.9
Timestamp requests
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprVpnStatsIcmpOutTimeRPs 3.1.1751.2.18.10.9.1.10
Timestamp replies
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprVpnStatsIcmpOutInfoRQs 3.1.1751.2.18.10.9.1.11
Information Request
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprVpnStatsIcmpOutInfoRPs 3.1.1751.2.18.10.9.1.12
Echo Reply
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprVpnStatsIcmpOutMaskRQs 3.1.1751.2.18.10.9.1.13
Mask Request
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprVpnStatsIcmpOutMaskRPs 3.1.1751.2.18.10.9.1.14
Mask Reply
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprVpnStatsIcmpOutErrors 3.1.1751.2.18.10.9.1.15
unrecognized ICMP type
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprVpnStatsIcmpInErrors 3.1.1751.2.18.10.9.1.16
error in received icmp message
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprVpnStatsIcmpInEchoRQs 3.1.1751.2.18.10.9.1.17
received echo request
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprVpnStatsIcmpInAddrMasks 3.1.1751.2.18.10.9.1.18
received mask request
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprVpnStatsIcmpInAddrMaskReps 3.1.1751.2.18.10.9.1.19
received mask reply
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprVpnStatsIcmpInEchoReps 3.1.1751.2.18.10.9.1.20
received echo replies
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprVpnStatsIcmpInDestUnreachs 3.1.1751.2.18.10.9.1.21
received destination unreacheable message
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprVpnStatsIcmpInSrcQuenchs 3.1.1751.2.18.10.9.1.22
received source quench
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprVpnStatsIcmpInTimeExcds 3.1.1751.2.18.10.9.1.23
received time exceeded message
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprVpnStatsIcmpInParamProbs 3.1.1751.2.18.10.9.1.24
received parameter problem message
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprVpnStatsIcmpInTimeStamps 3.1.1751.2.18.10.9.1.25
received time stamp request
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprVpnStatsIcmpInTimeStampsReps 3.1.1751.2.18.10.9.1.26
received time stamp replies
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprStatsTable 3.1.1751.2.18.11.10
The table which holds viprStatsEntry data.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ViprStatsEntry

viprStatsEntry 3.1.1751.2.18.11.10.1
A table entry for VPN related statistics information.
Status: current Access: not-accessible
OBJECT-TYPE    
  ViprStatsEntry  

viprStatsReset 3.1.1751.2.18.11.10.1.1
A SNMP set action to reset VPN related statistics info.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reset(1)  

viprStatsPacketsRxHi 3.1.1751.2.18.11.10.1.2
Good packets received from the backplane
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprStatsPacketsRxLo 3.1.1751.2.18.11.10.1.3
Good packets received from the backplane
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprStatsPacketsTxHi 3.1.1751.2.18.11.10.1.4
packets transmitted to the backplane
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprStatsPacketsTxLo 3.1.1751.2.18.11.10.1.5
packets transmitted to the backplane
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprStatsMismatchCrcHi 3.1.1751.2.18.11.10.1.6
packets received has been dropped due to a mismached CRC
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprStatsMismatchCrcLo 3.1.1751.2.18.11.10.1.7
packets received has been dropped due to a mismached CRC
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprStatsInsufficientPcktsHi 3.1.1751.2.18.11.10.1.8
packet received length is greater than the number of cells received
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprStatsInsufficientPcktsLo 3.1.1751.2.18.11.10.1.9
packet received length is greater than the number of cells received
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprStatsExceedAal5CellsHi 3.1.1751.2.18.11.10.1.10
number of cells received is greater than the actual length of the aal5
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprStatsExceedAal5CellsLo 3.1.1751.2.18.11.10.1.11
number of cells received is greater than the actual length of the aal5
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprStatsPrototypeErrorsHi 3.1.1751.2.18.11.10.1.12
unrecognized encapsulation type
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprStatsPrototypeErrorsLo 3.1.1751.2.18.11.10.1.13
unrecognized encapsulation type
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprStatsArpProtoRxHi 3.1.1751.2.18.11.10.1.14
ARP received
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprStatsArpProtoRxLo 3.1.1751.2.18.11.10.1.15
ARP received
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprStatsIPInHdrErrorsHi 3.1.1751.2.18.11.10.1.16
IP packeted received has a bad header
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprStatsIPInHdrErrorsLo 3.1.1751.2.18.11.10.1.17
IP packeted received has a bad header
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprStatsIPInAddrErrorsHi 3.1.1751.2.18.11.10.1.18
IP packeted received has a bad IP Address
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprStatsIPInAddrErrorsLo 3.1.1751.2.18.11.10.1.19
IP packeted received has a bad IP Address
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprSubChnlStatsTable 3.1.1751.2.18.12.17
The table which holds viprSubChnlStatsEntry data.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ViprSubChnlStatsEntry

viprSubChnlStatsEntry 3.1.1751.2.18.12.17.1
A table entry that contains IP interface sub channel statistics.
Status: current Access: not-accessible
OBJECT-TYPE    
  ViprSubChnlStatsEntry  

viprSubChnlStatsInCellCountHiA 3.1.1751.2.18.12.17.1.1
cells received on rt interface from another conn
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprSubChnlStatsInCellCountLoA 3.1.1751.2.18.12.17.1.2
cells received on rt interface from another conn
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprSubChnlStatsOutCellCountHiA 3.1.1751.2.18.12.17.1.3
cells sent out of a rt interface to another dest
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprSubChnlStatsOutCellCountLoA 3.1.1751.2.18.12.17.1.4
cells sent out of a rt interface to another dest
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprSubChnlStatsInCellCountHiB 3.1.1751.2.18.12.17.1.5
cells received on atm/fr/bridge physical interface
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprSubChnlStatsInCellCountLoB 3.1.1751.2.18.12.17.1.6
cells received on atm/fr/bridge physical interface
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprSubChnlStatsOutCellCountHiB 3.1.1751.2.18.12.17.1.7
cell transmitted out of a physical atm/fr/bridge interface
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprSubChnlStatsOutCellCountLoB 3.1.1751.2.18.12.17.1.8
cell transmitted out of a physical atm/fr/bridge interface
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprSubChnlStatsTimer 3.1.1751.2.18.12.17.1.9
Number of seconds stats have been collecting
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprSubChnlStatsInOdometerCellCountHiA 3.1.1751.2.18.12.17.1.10
odometer cells received on rt interface from another conn
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprSubChnlStatsInOdometerCellCountLoA 3.1.1751.2.18.12.17.1.11
odometer cells received on rt interface from another conn
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprSubChnlStatsOutOdometerCellCountHiA 3.1.1751.2.18.12.17.1.12
odometer cells sent out of a rt interface to another dest
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprSubChnlStatsOutOdometerCellCountLoA 3.1.1751.2.18.12.17.1.13
odometer cells sent out of a rt interface to another dest
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprSubChnlStatsInOdometerCellCountHiB 3.1.1751.2.18.12.17.1.14
odometer cells received on atm/fr/bridge physical interface
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprSubChnlStatsInOdometerCellCountLoB 3.1.1751.2.18.12.17.1.15
odometer cells received on atm/fr/bridge physical interface
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprSubChnlStatsOutOdometerCellCountHiB 3.1.1751.2.18.12.17.1.16
odometer cells transmitted out of a physical atm/fr/bridge interface
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprSubChnlStatsOutOdometerCellCountLoB 3.1.1751.2.18.12.17.1.17
odometer cells transmitted out of a physical atm/fr/bridge interface
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprSubChnlStatsOdometerTimer 3.1.1751.2.18.12.17.1.18
Odometer Number of seconds stats have been collecting
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprSubChnlStatsOdometerReset 3.1.1751.2.18.12.17.1.19
to reset the subchannel statistics
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reset(1)  

viprSubChnlStatsCellsDroppedB 3.1.1751.2.18.12.17.1.20
Cells Dropped on the Incoming side of B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

viprSubChnlStatsCellsTaggedB 3.1.1751.2.18.12.17.1.21
Cells Tagged on the Incoming side of B
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

virtualIntfStatsTable 3.1.1751.2.18.11.11
Table of Virtual Interfaces Configurations
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VirtualIntfStatsEntry

virtualIntfStatsEntry 3.1.1751.2.18.11.11.1
Index is the Interface and the Virutal Interface
Status: current Access: not-accessible
OBJECT-TYPE    
  VirtualIntfStatsEntry  

virtualIntfStatsIf 3.1.1751.2.18.11.11.1.1
Interface index for side A of an ATM-to-ATM PVC VCC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntfIndex  

virtualIntfStatsVi 3.1.1751.2.18.11.11.1.2
VI value. Def Val is 1 because 0 cannot be configured
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..1024  

virtualIntfStatsEgrCellCount 3.1.1751.2.18.11.11.1.3
Egress Cell Count on VI
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

virtualIntfStatsTimer 3.1.1751.2.18.11.11.1.4
Time, in seconds, since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..899  

virtualIntfStatsReset 3.1.1751.2.18.11.11.1.5
stats reset field.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reset(1)  

cardFwVerTable 3.1.1751.2.18.23.1
Table of card firware version status
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CardFwVerEntry

cardFwVerEntry 3.1.1751.2.18.23.1.1
Row definition for card firmware version status
Status: current Access: not-accessible
OBJECT-TYPE    
  CardFwVerEntry  

cardFwVerSlot 3.1.1751.2.18.23.1.1.1
card slot number
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..24  

cardFwVerType 3.1.1751.2.18.23.1.1.2
Card type
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

cardFwVerCurrent 3.1.1751.2.18.23.1.1.3
Card firmware version currently loaded on firmware
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(13)  

cardFwVerCurrentIsDefault 3.1.1751.2.18.23.1.1.4
curent driver is default
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cardFwVerNext 3.1.1751.2.18.23.1.1.5
Card firmware version that user wants to upgrade to. The values are limited those supported by the release.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(13)  

cardFwVerNextIsDefault 3.1.1751.2.18.23.1.1.6
next driver is default
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

cardFwDnldStatus 3.1.1751.2.18.23.1.1.7
firmware download procedure status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER failed(1), retry(2), progress(3), done(4), wrongCardType(5), wrongCardSType(6), drvUnavailable(7), drvInvHdrChksum(8), drvInvRecChksum(9), reqRepTimeout(10), cmplRepTimeout(11), mapCorrupted(12), mapUnavailable(13), mapInvChksum(14), mapNameImprop(15), cfgCorrupted(16), cfgUnavailable(17), cfgInvChksum(18), removeCardBeforeFinish(19), ioUnsupported(20)  

cardFwRetries 3.1.1751.2.18.23.1.1.8
Number of times firmware download procedure failed consequently.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

fwDriverTable 3.1.1751.2.18.23.2
Table of available firmware drivers
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FwDriverEntry

fwDriverEntry 3.1.1751.2.18.23.2.1
Row definition for available firmware drivers
Status: current Access: not-accessible
OBJECT-TYPE    
  FwDriverEntry  

fwSlotId 3.1.1751.2.18.23.2.1.1
driver slot id
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

fwDriverType 3.1.1751.2.18.23.2.1.2
firmware driver type - definition consistent with cardType.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

fwIsDefault 3.1.1751.2.18.23.2.1.3
firmware driver wether default or not
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

fwDriverName 3.1.1751.2.18.23.2.1.4
firmware driver file name
Status: current Access: not-accessible
OBJECT-TYPE    
  OCTET STRING Size(13)  

fwDriverFrn 3.1.1751.2.18.23.2.1.5
Firmware Release Number of firmware driver
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

fwDriverSize 3.1.1751.2.18.23.2.1.6
file size of firmware driver
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

fwDriverChecksum 3.1.1751.2.18.23.2.1.7
checksum of firmware driver file
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tasCmprsAnnceId 3.1.1751.2.18.25.31
Announcement ID for this announcement file to be compressed.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..100  

tasCmprsAnnceReplaceId 3.1.1751.2.18.25.32
Announcement ID of the announcement file to be replaced from the announcement table by this file.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..100  

tasCmprsAnnceFilename 3.1.1751.2.18.25.33
File name for this announcement which is to be compressed.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(79)  

tasCmprsAnnceDescription 3.1.1751.2.18.25.34
Description for this announcement which is to to be compressed.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(255)  

tasCmprsAnnceCmprsType 3.1.1751.2.18.25.35
The type of compression used for storing this announcement.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER uncompressed(1), compress8k(2), compress16k(3), compress32k(4)  

tasCmprsAnnceType 3.1.1751.2.18.25.36
The type of this announcement.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER voice(1), toneVoice(2), userTones(3), music(4), musicVoice(5), toneMusic(6)  

tasCmprsAnnceIntfIndex 3.1.1751.2.18.25.37
Interface index in SSPPCCC format of TASM card on which this announcement is to be compressed.
Status: current Access: read-write
OBJECT-TYPE    
  IntfIndex  

tasCmprsAction 3.1.1751.2.18.25.38
Action to be performed on this announcement.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER compress(1), delete(2), store(3)  

tasTstAnnceId 3.1.1751.2.18.25.39
Announcement ID to be played for testing.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..100  

tasTstAnnceIntfIndex 3.1.1751.2.18.25.40
Interface index in SSPPCCC format of CE card on which this announcement is to be played for testing.
Status: current Access: read-write
OBJECT-TYPE    
  IntfIndex  

tasTstAnnceLawType 3.1.1751.2.18.25.41
The type of CE card towards which this announcement is to be played. A-Law is for E1 and U-Law is for DS1
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER a-Law(1), u-Law(2)  

tasTstAnnceAction 3.1.1751.2.18.25.42
Action to be performed on this announcement for testing.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER playStart(1), playStop(2), playAbort(3)  

tasTstLineId 3.1.1751.2.18.25.43
Test ID to be started for line testing.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

tasTstLineIntfIndex 3.1.1751.2.18.25.44
Interface index in SSPPCCC format of CE card on which this test is to be initiated.
Status: current Access: read-write
OBJECT-TYPE    
  IntfIndex  

tasTstLineAction 3.1.1751.2.18.25.45
Test action to be performed.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER tstStart(1), tstStop(2), tstAbort(3)  

tasMemIntfIndex 3.1.1751.2.18.25.46
Interface index in SSPPCCC format of TASM card on which the memory is to be initialised.
Status: current Access: read-write
OBJECT-TYPE    
  IntfIndex  

tasMemAction 3.1.1751.2.18.25.47
Test action to be performed.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER re-initialize(1)  

toneAnnceIpAddress 3.1.1751.2.18.25.48
IP Address for announcement ftp server.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

toneAnnceAccountName 3.1.1751.2.18.25.49
ftp account name for access to announcement ftp server.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(20)  

toneAnnceAccountPassword 3.1.1751.2.18.25.50
ftp account password for access to announcement ftp server.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(20)  

toneAnnceSourceFile 3.1.1751.2.18.25.51
announcement file with complete path on the ftp server
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(79)  

toneAnnceDestinationFile 3.1.1751.2.18.25.52
The announcementSourceFile will be renamed with MS DOS file format and placed in the /scsi/announce directory on the disk.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(12)  

toneAnnceFtpStatus 3.1.1751.2.18.25.53
Current status of the ftp announcement download. Status of the software announcement. noActivity is the initial start state from boot-up. working is set while ftp'ing the announcement. The final state is one of doneSuccessfully, doneWithError, or aborted, all self-explanatory. It will stay in this state until re-boot or starting an announcement. If the state is doneWithError then announcementSwErrorStatus will be set to reflect the type of error.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noActivity(1), working(2), doneSuccessfully(3), doneWithError(4), aborted(5)  

toneAnnceFtpErrorStatus 3.1.1751.2.18.25.54
The result of the finish of the ftp software announcement download. Set to a value 3-21 if announcementSwCopyStatus is doneWithError. Set to none if announcementFtpCopyStatus is doneSuccessfully. Set to userAbort if announcementSwCopyStatus is aborted.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), userAbort(2), invalidIpAddress(3), invalidAccountName(4), invalidAccountPassword(5), invalidSourceFile(6), invalidDstFileNameFormat(7), dstFileNameAlreadyExist(8), tooManyAnnouncementNow(9), diskSpaceUsageExceed(10), unableToOpenFile(11), unableToMakeFtpConnection(12), unableToWriteFile(13), unableToCompleteFtp(14), unableToSpawnTask(15), unableToOpenScsiAnncDir(16), statFails(17)  

toneAnnceFtpAction 3.1.1751.2.18.25.55
start ftp announcement files. When announcementFtpCopyStatus is working, the start request will be ignored. Abort will have effect only when announcementFtpCopystatus is working.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER start(1), abort(2)  

atmTrunkingIWFBaseGroup 3.1.1751.2.18.28.1
OBJECT IDENTIFIER    

atmTrunkingIWFIdentifier 3.1.1751.2.18.28.1.1
IWF ID for the local endpoint
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmTrunkingIWFLocalAddress 3.1.1751.2.18.28.1.2
IWF ATM address for the local endpoint
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(20)  

atmTrunkingIWFMaxRemoteIWF 3.1.1751.2.18.28.1.3
Maximum remote IWF that can connect to this endpoint
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmTrunkingIWFAdminStatus 3.1.1751.2.18.28.1.4
Indicates whether the Local IWF is active or not
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER up(1), down(2), delete(3)  

atmTrunkingRemoteIWFTable 3.1.1751.2.18.28.2
Remote IWF table
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmTrunkingRemoteIWFEntry

atmTrunkingRemoteIWFEntry 3.1.1751.2.18.28.2.1
Entry in atmTrunkingRemoteIWFTable
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmTrunkingRemoteIWFEntry  

atmTrunkingRemoteIWFIdentifier 3.1.1751.2.18.28.2.1.1
IWF ID for the remote IWF
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

atmTrunkingRemoteIWFAddress 3.1.1751.2.18.28.2.1.2
IWF ATM address for the remote IWF
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(20)  

atmTrunkingRemoteIWFTrnkMode 3.1.1751.2.18.28.2.1.3
Maximum remote IWF that can connect to this endpoint
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER switched(1), non-switched(2)  

atmTrunkingRemoteIWFAdminStatus 3.1.1751.2.18.28.2.1.4
Indicates whether the Local IWF is active or not
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER up(1), down(2)  

atmTrunkingRemoteIWFRowStatus 3.1.1751.2.18.28.2.1.5
Maximum remote IWF that can connect to this endpoint
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

atmTrunkingSigVccTable 3.1.1751.2.18.28.3
Table of iwf signaling vcc configuration entities
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmTrunkingSigVccEntry

atmTrunkingSigVccEntry 3.1.1751.2.18.28.3.1
Entry in atmTrunkingSigVccTable
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmTrunkingSigVccEntry  

atmTrunkingSigVccRmtIWFIdentifier 3.1.1751.2.18.28.3.1.1
IWF ID for the remote IWF
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

atmTrunkingSigVccIdentifier 3.1.1751.2.18.28.3.1.2
Vcc ID assigned by the owner of this signaling Vcc
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..16383  

atmTrunkingSigVccOutgoingIfIndex 3.1.1751.2.18.28.3.1.3
Intf index of the outgoing interface,readonly for SVC/SPVC
Status: current Access: read-create
OBJECT-TYPE    
  IntfIndex  

atmTrunkingSigVccOutgoingVpi 3.1.1751.2.18.28.3.1.4
VPI used at the outgoing interface, readonly for SVC/SPVC
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..4095  

atmTrunkingSigVccOutgoingVci 3.1.1751.2.18.28.3.1.5
VCI used at the outgoing interface, readonly for SVC/SPVC
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..65535  

atmTrunkingSigVccOwner 3.1.1751.2.18.28.3.1.6
Indicates who is the owner of the Sig VCC
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER local(1), remote(2)  

atmTrunkingSigVccInactiveTimer 3.1.1751.2.18.28.3.1.7
Inactive time period on which to clear the call
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmTrunkingSigVccType 3.1.1751.2.18.28.3.1.8
Indicates if the SigVcc should be setup as PVC/SPVC/SVC
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER pvc(1), spvc(2), svc(3)  

atmTrunkingSigVccSignaling 3.1.1751.2.18.28.3.1.9
Indicates the signalling protocol used between the IWFs
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER pss1(1), dss1(2), dpnss(3), other(4)  

atmTrunkingSigVccFwPcr01 3.1.1751.2.18.28.3.1.10
Forward PCR for the call
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmTrunkingSigVccBwPcr01 3.1.1751.2.18.28.3.1.11
Backward PCR for the call
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmTrunkingSigVccFwScr01 3.1.1751.2.18.28.3.1.12
Forward SCR for the call
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmTrunkingSigVccBwScr01 3.1.1751.2.18.28.3.1.13
Backward SCR for the call
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmTrunkingSigVccFwMbs01 3.1.1751.2.18.28.3.1.14
Forward MBS for the call
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmTrunkingSigVccBwMbs01 3.1.1751.2.18.28.3.1.15
Backward MBS for the call
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmTrunkingSigVccMaxAal2Vcc 3.1.1751.2.18.28.3.1.16
Maximum number of bearer VCCs controlled by this SigVcc
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmTrunkingSigVccActiveAal2Vcc 3.1.1751.2.18.28.3.1.17
Number of active bearer VCCs controlled by this SigVcc
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmTrunkingSigVccOperStatus 3.1.1751.2.18.28.3.1.18
Indicates whether the Local IWF is active or not
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER idle(1), outOfService(2), init(3), connecting(4), active(5), release(6)  

atmTrunkingSigVccRowStatus 3.1.1751.2.18.28.3.1.19
Row status
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

atmTrunkingSigVccViB 3.1.1751.2.18.28.3.1.20
VI to associate the Egress part of A2B connection
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..1024  

atmTrunkingSigVccVUNIB 3.1.1751.2.18.28.3.1.21
VUNI associated the Egress part of A2B connection
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..255  

atmTrunkingSigVccRetryTimer 3.1.1751.2.18.28.3.1.22
the time(seconds) to wait before attempting to establish the ATM Trunking Signalling VCC SPVC after previous failed call attempt. 0 indicates retries will be attempted immedi ately
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmTrunkingSigVccRetryLimit 3.1.1751.2.18.28.3.1.23
ATM Trunking Signalling VCC SPVC Retry Limit. 0 indicates unlimited
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmTrunkingSigVccRestart 3.1.1751.2.18.28.3.1.24
The active ATM Trunking SPVC is released, if necessary, and a new setup procedure is begun if restart, otherwise, noop.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER restart(1), noop(2)  

atmTrunkingSigVccPriority 3.1.1751.2.18.28.3.1.25
Priority of TrunkingSigVcc - priority-1 being highest priority .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER priority-1(1), priority-2(2), priority-3(3), priority-4(4)  

atmTrunkingSigVccRetryCounter 3.1.1751.2.18.28.3.1.26
Indicates how many attempts to establish the connection have failed. It is reset whenever a connection is successfully established or the SigVcc SPVC is restarted.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmTrunkingBrVccConfigTable 3.1.1751.2.18.28.4
Table of iwf aal2 bearer vcci configuration entities
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmTrunkingBrVccConfigEntry

atmTrunkingBrVccConfigEntry 3.1.1751.2.18.28.4.1
Row definition for iwf aal2 vcci configuration
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmTrunkingBrVccConfigEntry  

atmTrunkingBrVccRmtIWFId 3.1.1751.2.18.28.4.1.1
IWF ID for the remote IWF
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

atmTrunkingBrVccSigVccId 3.1.1751.2.18.28.4.1.2
Signalling Vcc associated with this Br Vcc
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..16383  

atmTrunkingBrVccId 3.1.1751.2.18.28.4.1.3
Id of the AAL2 Bear Vcc
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..4096  

atmTrunkingBrVccIf 3.1.1751.2.18.28.4.1.4
Intf index of the outgoing interface, readonly for SVC/SPVC
Status: current Access: read-create
OBJECT-TYPE    
  IntfIndex  

atmTrunkingBrVccVpi 3.1.1751.2.18.28.4.1.5
VPI value of this VCC connection. Valid range is a number between 0 and 4095.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..4095  

atmTrunkingBrVccVci 3.1.1751.2.18.28.4.1.6
VCI value of this VCC connection. Valid range is a number between 0 and 65535.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..65535  

atmTrunkingBrVccViB 3.1.1751.2.18.28.4.1.7
VI to associate the Egress part of A2B connection
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..1024  

atmTrunkingBrVccVUNIB 3.1.1751.2.18.28.4.1.8
VUNI associated the Egress part of A2B connection
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..255  

atmTrunkingBrVccServiceType 3.1.1751.2.18.28.4.1.9
service type
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER cbr-1(1), cbr-2(2), cbr-3(3), cbr-4(4), ubr(5), vbr-nrt2(6), vbr-nrt1(7), vbr-rt2(8), vbr-rt1(9), vbr-express(10)  

atmTrunkingBrVccSarType 3.1.1751.2.18.28.4.1.10
sar type
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER aal1(1), aal2(2)  

atmTrunkingBrVccOwner 3.1.1751.2.18.28.4.1.11
The owner of this Vcc
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER local(1), remote(2)  

atmTrunkingBrVccOperStatus 3.1.1751.2.18.28.4.1.12
The Operational Status of this Bearer Vcc
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER idle(1), outOfService(2), init(3), active(4), release(5)  

atmTrunkingBrVccFwAtmPcr01 3.1.1751.2.18.28.4.1.13
Forward pcr (0+1)
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmTrunkingBrVccBwAtmPcr01 3.1.1751.2.18.28.4.1.14
Backward pcr (0+1)
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmTrunkingBrVccFwAtmScr01 3.1.1751.2.18.28.4.1.15
Forward scr (0+1)
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmTrunkingBrVccBwAtmScr01 3.1.1751.2.18.28.4.1.16
Backward scr (0+1)
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmTrunkingBrVccFwAtmMbs01 3.1.1751.2.18.28.4.1.17
Forward Mbs (0+1)
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmTrunkingBrVccBwAtmMbs01 3.1.1751.2.18.28.4.1.18
Backward Mbs (0+1)
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmTrunkingBrVccConnType 3.1.1751.2.18.28.4.1.19
connection type
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER svc(1), spvc(2), pvc(3)  

atmTrunkingBrVccActiveChanCnt 3.1.1751.2.18.28.4.1.20
Number of currently active channels in this Vcc
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmTrunkingBrVccMaxAal2ChanId 3.1.1751.2.18.28.4.1.21
Max Id of channels supported within this br vcc
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 9..255  

atmTrunkingBrVccCircuitModeDataSupp 3.1.1751.2.18.28.4.1.22
Circuit mode data
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

atmTrunkingBrVccFrameModeSupp 3.1.1751.2.18.28.4.1.23
Frame mode data
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

atmTrunkingBrVccFaxModSupp 3.1.1751.2.18.28.4.1.24
FAX Demodulation
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

atmTrunkingBrVccCASPktXportSupp 3.1.1751.2.18.28.4.1.25
Channel Associated Signaling
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

atmTrunkingBrVccDTMFPktXportSupp 3.1.1751.2.18.28.4.1.26
DTMF Dialed Digits
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

atmTrunkingBrVccMFR1PktXportSupp 3.1.1751.2.18.28.4.1.27
MF-R1 Dialed Digits
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

atmTrunkingBrVccMFR2PktXportSupp 3.1.1751.2.18.28.4.1.28
MF-R2 Dialed Digits
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

atmTrunkingBrVccPCMEncoding 3.1.1751.2.18.28.4.1.29
DTMF Dialed Digits
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER none(1), a-law(2), u-law(3)  

atmTrunkingBrVccMaxFrameLength 3.1.1751.2.18.28.4.1.30
Maximum length of frame mode data
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 1..65535  

atmTrunkingBrVccIdleChannSuprSupp 3.1.1751.2.18.28.4.1.31
Idle Channel Supression
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

atmTrunkingBrVccSilenceDetSupp 3.1.1751.2.18.28.4.1.32
Silence Detection
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

atmTrunkingBrVccCompressionSpec 3.1.1751.2.18.28.4.1.33
Compression Type
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER none(1), g726-16K(2), g726-24K(3), g726-32K(4), g726-40K(5), g729a-8K(6)  

atmTrunkingBrVccAudioProfileSource 3.1.1751.2.18.28.4.1.34
Profile Source
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER itu-t(1), other(2)  

atmTrunkingBrVccAudioProfileId 3.1.1751.2.18.28.4.1.35
Profile ID
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 1..255  

atmTrunkingBrVccAvailBw 3.1.1751.2.18.28.4.1.36
Available Bandwidth left in this Vcc
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmTrunkingBrVccRowStatus 3.1.1751.2.18.28.4.1.37
Row status
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

atmTrunkingBrVccGr303Supp 3.1.1751.2.18.28.4.1.38
GR303 Support
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

atmTrunkingBrVccOamStatus 3.1.1751.2.18.28.4.1.39
Indicates the OAM monitoring status of side A. The 2 possible states are: Unsupp: No monitoring enabled. End-Pt: Atm side is only an end point, therefore it will respond to AIS/RDI.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unsupp(1), end-Pt(2)  

atmTrunkingBrVccInactiveTimer 3.1.1751.2.18.28.4.1.40
The time(in seconds) to wait before releasing the ATM Trunking Bearer VCC SVC after all narrow band calls are dropped
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmTrunkingBrVccRetryTimer 3.1.1751.2.18.28.4.1.41
the time(seconds) to wait before attempting to establish the ATM Trunking Bearer VCC SPVC after previous failed call attempt. 0 indicates retries will be attempted immediately
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmTrunkingBrVccRetryLimit 3.1.1751.2.18.28.4.1.42
ATM Trunking Bearer VCC SPVC Retry Limit. 0 indicates unlimited
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmTrunkingBrVccRestart 3.1.1751.2.18.28.4.1.43
The active ATM Trunking BrVcc SPVC is released, if necessary, and a new setup procedure is begun if 'restart', otherwise, noop.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER restart(1), noop(2)  

atmTrunkingBrVccCuTimer 3.1.1751.2.18.28.4.1.44
CuTimer represents combined use timer, is set to zero such that every ATM cell transmitted contains one, and only one, AAL2 packet, and the first octet of the AAL2 packet header follows immediately after the Start Field in the ATM cell payload. If the AAL2 packet payload is less than 44 octets, the remainder of the ATM cell payload following the end of the AAL2 packet shall be filled with zeros as padding. Each increment of CuTimer means 5ms more to wait. And cuTimer default value 4 means to wait 20ms before the ATM cell is sent out.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..8  

atmTrunkingBrVccPriority 3.1.1751.2.18.28.4.1.45
Priority of TrunkingBrVcc - priority-1 being highest priority .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER priority-1(1), priority-2(2), priority-3(3), priority-4(4)  

atmTrunkingBrVccRetryCounter 3.1.1751.2.18.28.4.1.46
Indicates how many attempts to establish the connection have failed. It is reset whenever a connection is successfully established or the BrVcc SPVC is restarted.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmTrunkingDataChannelConfigTable 3.1.1751.2.18.28.5
Table of iwf aal2 data channel configuration entities
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmTrunkingDataChannelConfigEntry

atmTrunkingDataChannelConfigEntry 3.1.1751.2.18.28.5.1
Row definition for iwf aal2 data channel configuration
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmTrunkingDataChannelConfigEntry  

atmTrunkingDataChannelRmtIWFId 3.1.1751.2.18.28.5.1.1
IWF ID for the remote IWF
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

atmTrunkingDataChannelSigVccId 3.1.1751.2.18.28.5.1.2
Vcc ID assigned by the owner of this signaling Vcc
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..16383  

atmTrunkingDataChannelBrVccId 3.1.1751.2.18.28.5.1.3
Id of the AAL2 Bear Vcc
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..4096  

atmTrunkingDataChannelId 3.1.1751.2.18.28.5.1.4
The AAL2 Channel Id of this channel
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 8..255  

atmTrunkingDataChanOperStatus 3.1.1751.2.18.28.5.1.5
Operational Status of this channel
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER idle(1), active(2)  

atmTrunkingDataChanOwner 3.1.1751.2.18.28.5.1.6
The owner of this channel
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER local(1), remote(2)  

atmTrunkingDataChanNBIntf 3.1.1751.2.18.28.5.1.7
The index of narrowband interface this channel is mapped to
Status: current Access: read-only
OBJECT-TYPE    
  IntfIndex  

h248TermIdTable 3.1.1751.2.18.30.1
Table of H.248 Terminations
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    H248TermIdEntry

h248TermIdEntry 3.1.1751.2.18.30.1.1
Row definition for H.248 Termination ID table
Status: current Access: not-accessible
OBJECT-TYPE    
  H248TermIdEntry  

h248TermSlotId 3.1.1751.2.18.30.1.1.1
Slot # for termination
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..99  

h248TermPhyPortId 3.1.1751.2.18.30.1.1.2
Physical Port # for termination
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..999  

h248TermLogPortId 3.1.1751.2.18.30.1.1.3
Logical Port # for termination
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..999  

h248TermChanId 3.1.1751.2.18.30.1.1.4
Chan # for termination
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..999  

h248TermVpi 3.1.1751.2.18.30.1.1.5
VPI # for termination. Value 0 is reserved to indicate N/A, e.g., TDM termination. Thus, VPI = h248TermVpi - 1, for h248TermVpi > 0.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..4096  

h248TermVci 3.1.1751.2.18.30.1.1.6
VCI # for termination. Value 0 is reserved to indicate N/A, e.g., TDM termination. Thus, VCI = h248TermVci - 1, for h248TermVci > 0.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..65536  

h248TermId 3.1.1751.2.18.30.1.1.7
Termination ID is provisioned by user and used for identifying termination between MGC and MG
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(32)  

h248TermAal2Cid 3.1.1751.2.18.30.1.1.8
AAL2 CID
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

h248TermActivation 3.1.1751.2.18.30.1.1.9
Activation for termination ID
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

h248TermRowStatus 3.1.1751.2.18.30.1.1.10
h248TermIdEntry row status
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

h248MaxNumberOfContexts 3.1.1751.2.18.31.1
The value of the property gives the maximum number of contexts that can exist at anytime. The NULL context is not included in this number.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

h248MaxTerminationsPerContext 3.1.1751.2.18.31.2
The max number of terminations allowed in a context.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

h248NormalMGExecutionTime 3.1.1751.2.18.31.3
Settable by the MGC to indicate the interval within which the MGC expects a response to any transaction from the MG (exclusive of the network delay). Value represents milliseconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

h248NormalMGCExecutionTime 3.1.1751.2.18.31.4
Settable by the MGC to indicate the interval within which the MG expects a response to any transaction from the MG (exclusive of the network delay). Value represents milliseconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

h248MGProvisionalResponseTimerValue 3.1.1751.2.18.31.5
Indicates the time within which the MGC should expect a Pending Response from the MG if a Transaction can not be completed. Initially set to h248NormalMGExecutionTime, plus network delay, but maybe lowered. Value represents milliseconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

h248MGCProvisionalResponseTimerValue 3.1.1751.2.18.31.6
Indicates the time within which the MG should expect a Pending Response from the MGC if a Transaction can not be completed. Initially set to h248NormalMGCExecutionTime, plus network delay, but maybe lowered. Value represents milliseconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

h248MGCIpAddress1 3.1.1751.2.18.31.7
The IP address of the 1st MGC.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

h248MGCIpAddress2 3.1.1751.2.18.31.8
The IP address of the 2nd MGC.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

protectionGroupTable 3.1.1751.2.18.29.1
Table of interface protection group attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ProtectionGroupEntry

protectionGroupEntry 3.1.1751.2.18.29.1.1
Defines one interface protection group
Status: current Access: not-accessible
OBJECT-TYPE    
  ProtectionGroupEntry  

pgtGroupId 3.1.1751.2.18.29.1.1.1
a user selected logical number representing a protection group uniquely within a PSAX
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

pgtSwitchoverMethod 3.1.1751.2.18.29.1.1.2
switchover method to switch traffic from failed primary interface to available standby interface. In auto method, PSAX automatically switches the traffic without user intervention. In manual method, a failed primary does not switch traffic and gives control to user to do so.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), manual(2)  

pgtSwitchbackMethod 3.1.1751.2.18.29.1.1.3
switchback method to switch traffic from a standby to its corresponding recovered primary interface. In auto method, PSAX automatically switches the traffic without user intervention. In manual method, standby does not switch traffic and gives control to user to do so.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), manual(2)  

pgtStandbySelection 3.1.1751.2.18.29.1.1.4
Standby selection method determines the order of selection of standby when primary interface fails. The options are: sequential -- internally select next higher available standby to the last one, latest_used -- used last one freed, oldest_used -- used to longest idle one, random ­ randomly select one, explicit -- selected by user.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER sequential(1), latest-used(2), oldest-used(3), random(4), explicit(5)  

pgtRowStatus 3.1.1751.2.18.29.1.1.5
row status
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

interfaceProtectionTable 3.1.1751.2.18.29.2
Table of interface protection attributes
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    InterfaceProtectionEntry

interfaceProtectionEntry 3.1.1751.2.18.29.2.1
Defines attributes for interface protection
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceProtectionEntry  

iptGroupId 3.1.1751.2.18.29.2.1.1
a user selected logical number representing a protection group uniquely within a PSAX.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

iptLogicalIntfId 3.1.1751.2.18.29.2.1.2
Logical interface number assigned by user
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

iptPhysicalIntfId 3.1.1751.2.18.29.2.1.3
physical interface in SSPPCCC format
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

iptIntfType 3.1.1751.2.18.29.2.1.4
interface primary or secondary.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER primary(1), secondary(2)  

iptOperState 3.1.1751.2.18.29.2.1.5
indicates operational state of the interface.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER inactive(1), active(2)  

iptOperatingIntf 3.1.1751.2.18.29.2.1.6
protection operational state of the interface. Indicates which logical interface is carrying traffic originally configured for this interface.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

iptProtCommand 3.1.1751.2.18.29.2.1.7
protection operational state of the interface. Indicates which logical interface is carrying traffic originally configured for this interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), switchover(2), switchback(3)  

iptSelectedStandby 3.1.1751.2.18.29.2.1.8
Standby interface logical number on which to switch traffic. Used only in case of manual switchover with explicit standby selection.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

iptRowStatus 3.1.1751.2.18.29.2.1.9
row status
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

systemColdStartNotify 3.1.1751.2.18.8.1.1
Info : System has successfully completed initialization from a complete power down stage and is ready for operation.
Status: current Access: read-write
NOTIFICATION-TYPE    

systemWarmStartNotify 3.1.1751.2.18.8.1.2
Info : System has successfully completed initialization from a user or other system level interrupt or restart and is ready for operation.
Status: current Access: read-write
NOTIFICATION-TYPE    

ecdBootFailureNotify 3.1.1751.2.18.8.1.3
Critical : System failed in the Boot (startup) procedures. Please call Support immediately to resolve the problem.
Status: current Access: read-write
NOTIFICATION-TYPE    

referenceClockFailNotify 3.1.1751.2.18.8.1.4
Critical : The reference clock used for the operation of the bus-based backplane has failed. Please call Support immediately to resolve the problem.
Status: current Access: read-write
NOTIFICATION-TYPE    

referenceClockClearedNotify 3.1.1751.2.18.8.1.5
Info : The error in the backplane reference clock has been corrected.
Status: current Access: read-write
NOTIFICATION-TYPE    

compositeClockFailNotify 3.1.1751.2.18.8.1.6
Critical : The composite clock has failed. Please call Support immediately to resolve the problem.
Status: current Access: read-write
NOTIFICATION-TYPE    

compositeClockClearedNotify 3.1.1751.2.18.8.1.7
Info : The error in the composite clock has been corrected.
Status: current Access: read-write
NOTIFICATION-TYPE    

stratumModeChangeNotify 3.1.1751.2.18.8.1.8
Info : The current operational status of the Stratum card has changed.
Status: current Access: read-write
NOTIFICATION-TYPE    

powerSupplyStatusNotify 3.1.1751.2.18.8.1.9
Minor : Indicates the status of the power supply.
Status: current Access: read-write
NOTIFICATION-TYPE    

softwareDownloadStatusNotify 3.1.1751.2.18.8.1.10
Info : Indicates the completion status of the ftp download of a software upgrade.
Status: current Access: read-write
NOTIFICATION-TYPE    

muxReadyConfirmReceivedNotify 3.1.1751.2.18.8.1.11
Info : Indicates that the MUX (AC 120) has received a MUX_READY_CONF message in response to the MUX_READY_IND message when the AC 120 is configured as the TCP client for the AC 120 to Signalling Gateway connection.
Status: current Access: read-write
NOTIFICATION-TYPE    

muxReadyConfirmNotReceivedNotify 3.1.1751.2.18.8.1.12
Major : If AC 120 is configured as TCP client, this trap is sent if the MUX_READY_CONF message is not received after sending the MUX_READY_IND message three times. This indicates unexpected behavior on the AC 120 to Signalling Gateway link.
Status: current Access: read-write
NOTIFICATION-TYPE    

oneWayMessageWhileInTwoWayStateNotify 3.1.1751.2.18.8.1.13
Major : This trap indicates that a one way message is received from the Signalling Gateway (SG) when the AC 120 is in the two way state of the keep-alive protocol on the TCP link between the AC 120 and the SG.
Status: current Access: read-write
NOTIFICATION-TYPE    

inactivityTimerExpiredNotify 3.1.1751.2.18.8.1.14
Major : Sent by the AC 120 when the inactivity timer of the keep-alive protocoal expires, i.e. when the AC 120 does not see a message from the Signalling Gateway on the TCP link during the time period specified by the inactivity timer value setting.
Status: current Access: read-write
NOTIFICATION-TYPE    

keepAliveTimerExpiredInLlDownStateNotify 3.1.1751.2.18.8.1.15
Major : Sent by the AC 120 when the keep-alive timer expires in the LLDOWN state of the keep-alive protocol, i.e. when the AC 120 does not see a keep-alive message from the Signalling Gateway on the TCP link during the time period specified by the keep-alive timer setting.
Status: current Access: read-write
NOTIFICATION-TYPE    

keepAliveTimerExpiredInOneWayStateNotify 3.1.1751.2.18.8.1.16
Major : Sent by the AC 120 when the keep-alive timer expires in the ONE-WAY state of the keep-alive protocol, i.e. when the AC 120 does not see a keep-alive message from the Signalling Gateway on the TCP link during the time period specified by the keep-alive timer setting.
Status: current Access: read-write
NOTIFICATION-TYPE    

completeClockFailedNotify 3.1.1751.2.18.8.1.17
Critical : The stratum cards have either been removed or have failed leading to no clock being provided.
Status: current Access: read-write
NOTIFICATION-TYPE    

completeClockRecoveredNotify 3.1.1751.2.18.8.1.18
Info : A stratum card is now available to provide a clock source.
Status: current Access: read-write
NOTIFICATION-TYPE    

backplaneCircuitryFailedNotify 3.1.1751.2.18.8.1.19
Critical : There is no activity on the cell bus. Please call Support immediately to resolve the problem.
Status: current Access: read-write
NOTIFICATION-TYPE    

backplaneCircuitryRecoveredNotify 3.1.1751.2.18.8.1.20
Info : The cpu card is able to detect activity on the cell bus.
Status: current Access: read-write
NOTIFICATION-TYPE    

remoteRebootNotify 3.1.1751.2.18.8.1.21
Info : Indicates the result of the requested reboot action.
Status: current Access: read-write
NOTIFICATION-TYPE    

saveConfigurationNotify 3.1.1751.2.18.8.1.22
Info : Indicates the result of the requested save configuration.
Status: current Access: read-write
NOTIFICATION-TYPE    

versionConfigurationNotify 3.1.1751.2.18.8.1.23
Info : Indicates the completion status of the upgrade or downgrade.
Status: current Access: read-write
NOTIFICATION-TYPE    

fileTransferStatusNotify 3.1.1751.2.18.8.1.24
Info : Indicates the percent complete of the current upgrade, downgrade, or ftp download in progress.
Status: current Access: read-write
NOTIFICATION-TYPE    

ipOrMaskInvalidNotify 3.1.1751.2.18.8.1.25
Response : The indicated ip address is invalid.
Status: current Access: read-write
NOTIFICATION-TYPE    

alarmCardInputChangeNotify 3.1.1751.2.18.8.1.26
Info : Indicates that the deviceId with alarmCardReasonCode has changed its status.
Status: current Access: read-write
NOTIFICATION-TYPE    

removeConfigFilesNotify 3.1.1751.2.18.8.1.27
Info : Indicates the status of the removal of the configuration files.
Status: current Access: read-write
NOTIFICATION-TYPE    

alarmCardOutputChangeNotify 3.1.1751.2.18.8.1.28
Info : Indicates that the deviceId with alarmCardReasonCode has changed its status.
Status: current Access: read-write
NOTIFICATION-TYPE    

alarmCardAcoChangeNotify 3.1.1751.2.18.8.1.29
Info : Indicates the action taken by the indicated type of the audible alarm.
Status: current Access: read-write
NOTIFICATION-TYPE    

snmpCommunityStringsChangedToPublicNotify 3.1.1751.2.18.8.1.30
Critical : An error has been detected in the agt.pty file and the community strings have been changed to be public.
Status: current Access: read-write
NOTIFICATION-TYPE    

pnniNodeCfgNotify 3.1.1751.2.18.8.1.31
Info : Indicates that a PNNI Node has been created.
Status: current Access: read-write
NOTIFICATION-TYPE    

pnniNodeCfgFailNotify 3.1.1751.2.18.8.1.32
Info : Indicates that a PNNI Node Creation has failed.
Status: current Access: read-write
NOTIFICATION-TYPE    

pnniNodeModFailNotify 3.1.1751.2.18.8.1.33
Info : Indicates that a PNNI Node Modification has failed.
Status: current Access: read-write
NOTIFICATION-TYPE    

pnniNodeDelFailNotify 3.1.1751.2.18.8.1.34
Info : Indicates that a PNNI Node Deletion has failed.
Status: current Access: read-write
NOTIFICATION-TYPE    

pnniNodeOOSFailNotify 3.1.1751.2.18.8.1.35
Info : Indicates that the action of taking a PNNI Node Out of Service has failed.
Status: current Access: read-write
NOTIFICATION-TYPE    

pnniNodeISFailNotify 3.1.1751.2.18.8.1.36
Info : Indicates that the action of bringing a PNNI Node into service has failed.
Status: current Access: read-write
NOTIFICATION-TYPE    

pnniRtAddrCfgNotify 3.1.1751.2.18.8.1.37
Info : Indicates that a new PNNI Route Address has been Created.
Status: current Access: read-write
NOTIFICATION-TYPE    

pnniRtAddrCfgFailNotify 3.1.1751.2.18.8.1.38
Info : Indicates that a PNNI Route Address Configuration has failed.
Status: current Access: read-write
NOTIFICATION-TYPE    

pnniRtAddrModFailNotify 3.1.1751.2.18.8.1.39
Info : Indicates that a PNNI Route Address Modification has failed.
Status: current Access: read-write
NOTIFICATION-TYPE    

pnniRtAddrDelFailNotify 3.1.1751.2.18.8.1.40
Info : Indicates that a PNNI Route Address Deletion has failed.
Status: current Access: read-write
NOTIFICATION-TYPE    

pnniRtAddrAddByIlmiNotify 3.1.1751.2.18.8.1.41
Info : Indicates that an end system Address has been dynamically added to PNNI by ILMI.
Status: current Access: read-write
NOTIFICATION-TYPE    

pnniRtAddrDelByIlmiNotify 3.1.1751.2.18.8.1.42
Info : Indicates that an end system Address has been dynamically deleted from PNNI by ILMI.
Status: current Access: read-write
NOTIFICATION-TYPE    

callContrlResAllocFailNotify 3.1.1751.2.18.8.1.43
Info: Indicates that the configuration of call control resource allocation fails.
Status: current Access: read-write
NOTIFICATION-TYPE    

differentSystemSoftwareNotify 3.1.1751.2.18.8.1.44
Critical: Indicates that the primary and backup cpu's are running different versions of software. This could cause system problems since the database files will not be transferred between cpu's so a change of cpu will result.
Status: current Access: read-write
NOTIFICATION-TYPE    

inputPortClockFailNotify 3.1.1751.2.18.8.1.45
Critical : The input port clock has failed. Please call Support immediately to resolve the problem.
Status: current Access: read-write
NOTIFICATION-TYPE    

inputPortClockClearedNotify 3.1.1751.2.18.8.1.46
Info : The error in the input port clock has been corrected.
Status: current Access: read-write
NOTIFICATION-TYPE    

oldStratumCardNotify 3.1.1751.2.18.8.1.47
Critical : This trap indicates that the primary stratum card does not support this mode of operation being applied in the stratum configuration. Card must be upgraded. A default configuration is being applied to stratum
Status: current Access: read-write
NOTIFICATION-TYPE    

stratumCardMismatchNotify 3.1.1751.2.18.8.1.48
Critical : Indicates that the secondary stratum card does not support this mode of operation being applied to the primary stratum. Card must be upgraded.
Status: current Access: read-write
NOTIFICATION-TYPE    

tasCmprsAnnceNotify 3.1.1751.2.18.8.1.49
Info : Indicates the result of the requested compress announcement operation.
Status: current Access: read-write
NOTIFICATION-TYPE    

tasTstLineNotify 3.1.1751.2.18.8.1.50
Info : Indicates the result of the requested line test initiation operation.
Status: current Access: read-write
NOTIFICATION-TYPE    

tasMemNotify 3.1.1751.2.18.8.1.51
Info : Indicates the result of the requested TASM memory initiation operation.
Status: current Access: read-write
NOTIFICATION-TYPE    

ambientTemperatureChangeNotify 3.1.1751.2.18.8.1.52
Info : Indicates the ambient temperature has changed by 5 degrees centigrade since the last trap message.
Status: current Access: read-write
NOTIFICATION-TYPE    

systemInsuffMemNotify 3.1.1751.2.18.8.1.53
Info : no enough memory for one or more features to be turned on.
Status: current Access: read-write
NOTIFICATION-TYPE    

toneAnnceFtpStatusNotify 3.1.1751.2.18.8.1.54
Info : Indicates the completion status of the ftp download of a tone annoucement file.
Status: current Access: read-write
NOTIFICATION-TYPE    

tasmControlBlockResAllocFailNotify 3.1.1751.2.18.8.1.55
Info: Indicates that the configuration of tasm control block resource allocation fails. Data send with the trap: tasmControlBlockAllocFailReasonCode Possible values are: res-alloc-success(1), res-alloc-Fail-announce-control-blocks-mem-unavail(2), res-alloc-Fail-digit-control-blocks-mem-unavail(3), res-alloc-Fail-line-test-control-blocks-mem-unavail(4)
Status: current Access: read-write
NOTIFICATION-TYPE    

tasmCacheMemAllocFailNotify 3.1.1751.2.18.8.1.56
Info: Indicates that the configuration of tasm memory cache for announcement caching allocation fails. Data send with the trap:tasmCacheMemAllocFailReasonCode Possible values are: res-alloc-success(1), res-alloc-Fail-announce-cache-mem-unavail(2)
Status: current Access: read-write
NOTIFICATION-TYPE    

remoteDbOperationStatusNotify 3.1.1751.2.18.8.1.57
Info : Indicates the completion status of remote database operation.
Status: current Access: read-write
NOTIFICATION-TYPE    

sapphireInterfaceAddressAssignFailNotify 3.1.1751.2.18.8.1.58
Info: Indicates that the assignment of the Sapphire interface address on which TCP connect requests are sent to SoftSwitch when PSAX is configured as Client has failed. Data send with the trap: sapphireIntfAddressFailReasonCode Possible values are: address-ok(1), Address assignment succeeded fail-Ilegal-IP-address(2), Illegal IP address assigned address not matching fail-not-match-InBandManagement-Switch-CPU-IP-Address(3) In-Band Management IP or Switch IP or CPU IP address fail-Switch-or-CPU-IP-Address-unconfigured(4) Switch IP or CPU IP address unconfigured fail-InBandManagement-IP-Address-unconfigured(5) InBandManagement IP address unconfigured.
Status: current Access: read-write
NOTIFICATION-TYPE    

switchAlarmStatusChangeNotify 3.1.1751.2.18.8.1.59
Critical : Trap to notify a change in the status of the alarm on the switch.
Status: current Access: read-write
NOTIFICATION-TYPE    

chassisOverTempAlarmNotify 3.1.1751.2.18.8.1.60
Critical : Trap sent when the temperature of the chassis goes above or below a preset temperature threshold.
Status: current Access: read-write
NOTIFICATION-TYPE    

cardInsertionNotify 3.1.1751.2.18.8.2.1
Info : The indicated slot has had a card inserted into it.
Status: current Access: read-write
NOTIFICATION-TYPE    

cardRemovedOrFailedNotify 3.1.1751.2.18.8.2.2
Major : The indicated slot has changed state.
Status: current Access: read-write
NOTIFICATION-TYPE    

lineStatusChangedNotify 3.1.1751.2.18.8.2.3
Major : The indicated port has had a change in the line status.
Status: current Access: read-write
NOTIFICATION-TYPE    

firmwareDownloadSucceededNotify 3.1.1751.2.18.8.2.4
Info : The indicated slot has successfully completed a firmware download.
Status: current Access: read-write
NOTIFICATION-TYPE    

firmwareDownloadFailedNotify 3.1.1751.2.18.8.2.5
Minor : The indicated slot had the indicated failure during a firmware download.
Status: current Access: read-write
NOTIFICATION-TYPE    

moduleRebootNotify 3.1.1751.2.18.8.2.6
Major : This trap indicates that a cardType in cardSlot becomes busy and the CPU reboots it. This is different from when an I/O card is actually removed.
Status: current Access: read-write
NOTIFICATION-TYPE    

oc3APSStateChangeNotify 3.1.1751.2.18.8.2.7
Notification of a change in the APS state machine.
Status: current Access: read-write
NOTIFICATION-TYPE    

oc3APSSwitchoverNotify 3.1.1751.2.18.8.2.8
Notification of a switchover in an APS pair.
Status: current Access: read-write
NOTIFICATION-TYPE    

portModifyFailNotify 3.1.1751.2.18.8.2.9
Info : Notification that an attempt to modify an port parameters has failed.
Status: current Access: read-write
NOTIFICATION-TYPE    

stratumActivitySwitchOverNotify 3.1.1751.2.18.8.2.10
Info : The secondary stratum card has become the primary primary card.
Status: current Access: read-write
NOTIFICATION-TYPE    

imaGroupStatusChangeNotify 3.1.1751.2.18.8.2.11
The indicated SSPPCCC has a change in the states of the IMA Group Channel
Status: current Access: read-write
NOTIFICATION-TYPE    

interfaceCreatedNotify 3.1.1751.2.18.8.3.1
Info : Notification that an interface has been created.
Status: current Access: read-write
NOTIFICATION-TYPE    

interfaceDeletedNotify 3.1.1751.2.18.8.3.2
Info : Notification that an interface has been deleted.
Status: current Access: read-write
NOTIFICATION-TYPE    

interfaceModifiedNotify 3.1.1751.2.18.8.3.3
Info : Notification that an interface has been modified.
Status: current Access: read-write
NOTIFICATION-TYPE    

interfaceModifyFailNotify 3.1.1751.2.18.8.3.4
Info : Notification that an attempt to modify an interface has failed.
Status: current Access: read-write
NOTIFICATION-TYPE    

interfaceOutOfServiceNotify 3.1.1751.2.18.8.3.5
Major : Notification that an interface is now out of service.
Status: current Access: read-write
NOTIFICATION-TYPE    

interfaceInServiceNotify 3.1.1751.2.18.8.3.6
Info : Notification that an interface is now in service.
Status: current Access: read-write
NOTIFICATION-TYPE    

bridgeDomainFullNotify 3.1.1751.2.18.8.3.7
Info : The 15 ports available for the bridge domain are being used, leaving no space for an additional port.
Status: current Access: read-write
NOTIFICATION-TYPE    

bridgeDomainExceededForSlotNotify 3.1.1751.2.18.8.3.8
Info : The bridge domain number has been exceeded for the slot.
Status: current Access: read-write
NOTIFICATION-TYPE    

bridgeDomainNumberInUseNotify 3.1.1751.2.18.8.3.9
Info : Notification that a bridge domain number is currently in use.
Status: current Access: read-write
NOTIFICATION-TYPE    

bridgeDomainInServiceNotify 3.1.1751.2.18.8.3.10
Info : Notification that a bridge domain is now in service.
Status: current Access: read-write
NOTIFICATION-TYPE    

bridgeDomainNumberInvalidNotify 3.1.1751.2.18.8.3.11
Info : Indicates that this interface contains an invalid bridge domain number. In order to create a domain, associate a port with a domain, or bring an interface in service, a valid domain number must be provided.
Status: current Access: read-write
NOTIFICATION-TYPE    

signalingModifyFailNotify 3.1.1751.2.18.8.3.12
Info : This trap indicates that signaling has already been configured for this port and to change, you must bring all interfaces out of service -- including the channel specified in interfaceIndex.
Status: current Access: read-write
NOTIFICATION-TYPE    

lmiIntfStatusNotify 3.1.1751.2.18.8.3.13
Info : This trap indicates the status of an interface from the LMI perspective.
Status: current Access: read-write
NOTIFICATION-TYPE    

isdnLapdDownNotify 3.1.1751.2.18.8.3.14
Info : This trap indicates that LAPD on the ISDN interface has gone down.
Status: current Access: read-write
NOTIFICATION-TYPE    

isdnLapdUpNotify 3.1.1751.2.18.8.3.15
Info : This trap indicates that LAPD is functional on the specified ISDN interface.
Status: current Access: read-write
NOTIFICATION-TYPE    

bridgeDomainTimingRelationshipNotify 3.1.1751.2.18.8.3.16
Info : Trap sent when one of the following relationships is violated: (1) 2 * (BridgeForwardDelay - 1.0 sec) >= BridgeMaxAge (2) BridgeMaxAge >= 2 * (BridgeHelloTime + 1.0 sec).
Status: current Access: read-write
NOTIFICATION-TYPE    

ts16UsageModifyFailNotify 3.1.1751.2.18.8.3.17
Info : Indicates that either TS16 has been in use for data while trying to change e1 TS16 from CCS to CAS, or signaling is on for at least one of the channels while trying to change e1 TS16 from CAS to CCS.
Status: current Access: read-write
NOTIFICATION-TYPE    

ceServiceTypeModifyFailNotify 3.1.1751.2.18.8.3.18
Info : Indicates that configuring unstructured CE failed. Possible reasons are: (1) the port has been channelized; (2) the port has CAS turned on.
Status: current Access: read-write
NOTIFICATION-TYPE    

channelizationModifyFailNotify 3.1.1751.2.18.8.3.19
Info : Indicates that channelizing/unchannelizing failed. Possible reasons are: (1) the port has been configured for unstructured CE; (2) the port has CAS turned on.
Status: current Access: read-write
NOTIFICATION-TYPE    

cirEmSpvcConfiguredNotify 3.1.1751.2.18.8.3.20
Info : Notification that an endpoint has been configured as CES SPVC endpoint. Return value - interfaceIndex
Status: current Access: read-write
NOTIFICATION-TYPE    

cirEmSpvcConfigFailNotify 3.1.1751.2.18.8.3.21
Info : Notification that an attempt to configure an endpoint as CE SPVC endpoint has failed. Return values - interfaceIndex - spvcConfigFailureCode: An identified reason for failure while configuring/modifying SPVC parameters.
Status: current Access: read-write
NOTIFICATION-TYPE    

cirEmSpvcDeletedNotify 3.1.1751.2.18.8.3.22
Info : Notification that CE SPVC configuration has been deleted. Return value - interfaceIndex
Status: current Access: read-write
NOTIFICATION-TYPE    

cirEmSpvcModifiedNotify 3.1.1751.2.18.8.3.23
Info : Notification that a SPVC endpoint has been modified - this trap has been obsoleted 07/01/2001.
Status: current Access: read-write
NOTIFICATION-TYPE    

cirEmSpvcModifyFailNotify 3.1.1751.2.18.8.3.24
Info : Notification that an attempt to modify a CE SPVC endpoint has failed - this trap has been obsoleted 07/01/2001.
Status: current Access: read-write
NOTIFICATION-TYPE    

vbrSpvcConfiguredNotify 3.1.1751.2.18.8.3.25
Info : Notification that an endpoint has been configured as TE SPVC endpoint. Return value - interfaceIndex
Status: current Access: read-write
NOTIFICATION-TYPE    

vbrSpvcConfigFailNotify 3.1.1751.2.18.8.3.26
Info : Notification that an attempt to configure an endpoint as TE SPVC endpoint has failed. Return values - interfaceIndex - spvcConfigFailureCode: An identified reason for failure while configuring/modifying SPVC parameters.
Status: current Access: read-write
NOTIFICATION-TYPE    

vbrSpvcDeletedNotify 3.1.1751.2.18.8.3.27
Info : Notification that TE SPVC configuration has been deleted. Return value - interfaceIndex
Status: current Access: read-write
NOTIFICATION-TYPE    

vbrSpvcModifiedNotify 3.1.1751.2.18.8.3.28
Info : Notification that a SPVC endpoint has been modified - this trap has been obsoleted 07/01/2001.
Status: current Access: read-write
NOTIFICATION-TYPE    

vbrSpvcModifyFailNotify 3.1.1751.2.18.8.3.29
Info : Notification that an attempt to modify a TE SPVC endpoint has failed - this trap has been obsoleted 07/01/2001.
Status: current Access: read-write
NOTIFICATION-TYPE    

atmSpvcConfiguredNotify 3.1.1751.2.18.8.3.30
Info : Notification that an endpoint has been configured as ATM SPVC endpoint. Return value - interfaceIndex - A-side vpi/vci value
Status: current Access: read-write
NOTIFICATION-TYPE    

atmSpvcConfigFailNotify 3.1.1751.2.18.8.3.31
Info : Notification that an attempt to configure an endpoint as ATM SPVC endpoint has failed. Return value - interfaceIndex - A-side vpi/vci value - spvcConfigFailureCode: An identified reason for failure while configuring/modifying SPVC parameters.
Status: current Access: read-write
NOTIFICATION-TYPE    

atmSpvcDeletedNotify 3.1.1751.2.18.8.3.32
Info : Notification that ATM SPVC configuration has been deleted. Return value - interfaceIndex - A-side vpi/vci value
Status: current Access: read-write
NOTIFICATION-TYPE    

atmSpvcModifiedNotify 3.1.1751.2.18.8.3.33
Info : Notification that a SPVC endpoint has been modified - this trap has been obsoleted 07/01/2001.
Status: current Access: read-write
NOTIFICATION-TYPE    

atmSpvcModifyFailNotify 3.1.1751.2.18.8.3.34
Info : Notification that an attempt to modify a TE SPVC endpoint has failed - this trap has been obsoleted 07/01/2001.
Status: current Access: read-write
NOTIFICATION-TYPE    

cRC4ModifyFailNotify 3.1.1751.2.18.8.3.35
Info: Notification that modification of the CRC4 field of an E1 port failed.
Status: current Access: read-write
NOTIFICATION-TYPE    

imaGrpChannelFailNotify 3.1.1751.2.18.8.3.36
Info : The imaGrpChannelFailNotify trap indicates a failure in the IMA group. The imaGrpChannelStatus field indicates the reason for the failure.
Status: current Access: read-write
NOTIFICATION-TYPE    

atmImaIntfFailNotify 3.1.1751.2.18.8.3.37
Info : The atmImaIntfFailNotify trap indicates a failure in the physical IMA interface. The atmImaIntfStatus field indicates the reason for the failure.
Status: current Access: read-write
NOTIFICATION-TYPE    

imaGrpChannelClearedNotify 3.1.1751.2.18.8.3.38
Info : The imaGrpChannelClearedNotify trap indicates a failure has been cleared in an IMA group. The imaGrpChannelStatus field indicates the failure that has been cleared.
Status: current Access: read-write
NOTIFICATION-TYPE    

atmImaIntfClearedNotify 3.1.1751.2.18.8.3.39
Info : The atmImaIntfClearedNotify trap indicates a failure has been cleared in an IMA interface. The atmImaIntfStatus field indicates the failure that has been cleared.
Status: current Access: read-write
NOTIFICATION-TYPE    

pnniProtLnkUpAndAdv 3.1.1751.2.18.8.3.40
Info : Indicates that the Protocol Status of the PNNI Link is Up and Advertising.
Status: current Access: read-write
NOTIFICATION-TYPE    

pnniProtLinkUpAndNotAdv 3.1.1751.2.18.8.3.41
Info : Indicates that the Protocol Status of the PNNI Link is Up but not Advertising.
Status: current Access: read-write
NOTIFICATION-TYPE    

pnniProtLnkStatDown 3.1.1751.2.18.8.3.42
Info : Indicates that the Protocol Status of the PNNI Link is Down.
Status: current Access: read-write
NOTIFICATION-TYPE    

pnniIntfCfgFailNotify 3.1.1751.2.18.8.3.43
Info : Indicates that a PNNI Interface has failed to be Created.
Status: current Access: read-write
NOTIFICATION-TYPE    

viprPingTrap 3.1.1751.2.18.8.3.44
Info : The Vipr Task is notifying Network Management of the disposition of a previous Ping Request.
Status: current Access: read-write
NOTIFICATION-TYPE    

viprArpTrap 3.1.1751.2.18.8.3.45
Info : The Vipr Task is notifying Network Management of the disposition of a previous Arp Table Request.
Status: current Access: read-write
NOTIFICATION-TYPE    

viprRoutingTrap 3.1.1751.2.18.8.3.46
Info : The Vipr Task is notifying Network Management of the disposition of a previous Routing Table Request.
Status: current Access: read-write
NOTIFICATION-TYPE    

viprVpnTrap 3.1.1751.2.18.8.3.47
Info : Indicates success/fail of VPN level operations.
Status: current Access: read-write
NOTIFICATION-TYPE    

viprIpIntfTrap 3.1.1751.2.18.8.3.48
Info : Indicates success/fail of IP Network Interface level operations.
Status: current Access: read-write
NOTIFICATION-TYPE    

viprSubChanTrap 3.1.1751.2.18.8.3.49
Info : Indicates success/fail of Sub Channel level operations.
Status: current Access: read-write
NOTIFICATION-TYPE    

viprRtSrvTrap 3.1.1751.2.18.8.3.50
Info : Indicates success/fail of Vipr (Route Server) operations.
Status: current Access: read-write
NOTIFICATION-TYPE    

atmSvcIntfLayer2Up 3.1.1751.2.18.8.3.51
Info : Indicates that an ATM Svc Interface Assured Data Link is Up.
Status: current Access: read-write
NOTIFICATION-TYPE    

atmSvcIntfLayer2Down 3.1.1751.2.18.8.3.52
Info : Indicates that an ATM Svc Interface Assured Data Link is Down.
Status: current Access: read-write
NOTIFICATION-TYPE    

apsConfigurationModifyFailNotify 3.1.1751.2.18.8.3.53
Info: Notification that an attempt to modify an APS configuration has failed
Status: current Access: read-write
NOTIFICATION-TYPE    

viprStatRtTrap 3.1.1751.2.18.8.3.54
Info : Indicates success/fail of Static Route operations.
Status: current Access: read-write
NOTIFICATION-TYPE    

interfaceCreateFailNotify 3.1.1751.2.18.8.3.55
Info : Notification that an attempt to create an interface has failed. interfaceFailureReasonCode gives details.
Status: current Access: read-write
NOTIFICATION-TYPE    

virtualIntfCreatedNotify 3.1.1751.2.18.8.3.56
Response to creation of VI
Status: current Access: read-write
NOTIFICATION-TYPE    

virtualIntfModifiedNotify 3.1.1751.2.18.8.3.57
Response to modification of VI
Status: current Access: read-write
NOTIFICATION-TYPE    

virtualIntfDeleteNotify 3.1.1751.2.18.8.3.58
Response to deletion of VI
Status: current Access: read-write
NOTIFICATION-TYPE    

virtualIntfModifyFailNotify 3.1.1751.2.18.8.3.59
Response to Modify Fail of VI, Overload pvcFailureReasonCode
Status: current Access: read-write
NOTIFICATION-TYPE    

frAtmSpvcConfiguredNotify 3.1.1751.2.18.8.3.60
Info : Notification that an endpoint has been configured as FR SPVC endpoint. Return values - interfaceIndex - dlci value
Status: current Access: read-write
NOTIFICATION-TYPE    

frAtmSpvcConfigFailNotify 3.1.1751.2.18.8.3.61
Info : Notification that an attempt to configure an endpoint as FR SPVC endpoint has failed. Return values - interfaceIndex - dlci value - spvcConfigFailureCode: An identified reason for failure while configuring/modifying SPVC parameters.
Status: current Access: read-write
NOTIFICATION-TYPE    

frAtmSpvcDeletedNotify 3.1.1751.2.18.8.3.62
Info : Notification that FR SPVC configuration has been deleted. Return values - interfaceIndex - dlci value
Status: current Access: read-write
NOTIFICATION-TYPE    

frAtmSpvcModifiedNotify 3.1.1751.2.18.8.3.63
Info : Notification that a SPVC endpoint has been modified - this trap has been obsoleted 07/01/2001. Return values - interfaceIndex - dlci value
Status: current Access: read-write
NOTIFICATION-TYPE    

frAtmSpvcModifyFailNotify 3.1.1751.2.18.8.3.64
Info : Notification that an attempt to modify a FR SPVC endpoint has failed - this trap has been obsoleted 07/01/2001.
Status: current Access: read-write
NOTIFICATION-TYPE    

atmAtmSpvcConfiguredNotify 3.1.1751.2.18.8.3.65
Info : Notification that an endpoint has been configured as ATM SPVC endpoint. Return values - interfaceIndex - A-side vpi/vci values - remote NSAP address
Status: current Access: read-write
NOTIFICATION-TYPE    

atmAtmSpvcConfigFailNotify 3.1.1751.2.18.8.3.66
Info : Notification that an attempt to configure an endpoint as ATM SPVC endpoint has failed. Return values - interfaceIndex - A-side vpi/vci values - remote NSAP address - spvcConfigFailureCode: An identified reason for failure while configuring/modifying SPVC parameters
Status: current Access: read-write
NOTIFICATION-TYPE    

atmAtmSpvcDeletedNotify 3.1.1751.2.18.8.3.67
Info : Notification that ATM SPVC configuration has been deleted. Return values - interfaceIndex - A-side vpi/vci values - remote NSAP address
Status: current Access: read-write
NOTIFICATION-TYPE    

atmAtmSpvcModifiedNotify 3.1.1751.2.18.8.3.68
Info : Notification that a SPVC endpoint has been modified - this trap has been obsoleted 07/01/2001.
Status: current Access: read-write
NOTIFICATION-TYPE    

atmAtmSpvcModifyFailNotify 3.1.1751.2.18.8.3.69
Info : Notification that an attempt to modify a TE SPVC endpoint has failed - this trap has been obsoleted 07/01/2001.
Status: current Access: read-write
NOTIFICATION-TYPE    

cirAtmSpvcConfiguredNotify 3.1.1751.2.18.8.3.70
Info : Notification that an endpoint has been configured as CE SPVC endpoint. Return values - interfaceIndex - remote NSAP address
Status: current Access: read-write
NOTIFICATION-TYPE    

cirAtmSpvcConfigFailNotify 3.1.1751.2.18.8.3.71
Info : Notification that an attempt to configure an endpoint as CE SPVC endpoint has failed. Return values - interfaceIndex - remote NSAP address - spvcConfigFailureCode: An identified reason for failure while configuring/modifying SPVC parameters
Status: current Access: read-write
NOTIFICATION-TYPE    

cirAtmSpvcDeletedNotify 3.1.1751.2.18.8.3.72
Info : Notification that CE SPVC configuration has been deleted. Return values - interfaceIndex - remote NSAP address
Status: current Access: read-write
NOTIFICATION-TYPE    

cirAtmSpvcModifiedNotify 3.1.1751.2.18.8.3.73
Info : Notification that a SPVC endpoint has been modified - this trap has been obsoleted 07/01/2001.
Status: current Access: read-write
NOTIFICATION-TYPE    

cirAtmSpvcModifyFailNotify 3.1.1751.2.18.8.3.74
Info : Notification that an attempt to modify a CE SPVC endpoint has failed - this trap has been obsoleted 07/01/2001.
Status: current Access: read-write
NOTIFICATION-TYPE    

vbrAtmSpvcConfiguredNotify 3.1.1751.2.18.8.3.75
Info : Notification that an endpoint has been configured as TE SPVC endpoint. Return values - interfaceIndex - remote NSAP address
Status: current Access: read-write
NOTIFICATION-TYPE    

vbrAtmSpvcConfigFailNotify 3.1.1751.2.18.8.3.76
Info : Notification that an attempt to configure an endpoint as TE SPVC endpoint has failed. Return values - interfaceIndex - remote NSAP address - spvcConfigFailureCode: An identified reason for failure while configuring/modifying SPVC parameters
Status: current Access: read-write
NOTIFICATION-TYPE    

vbrAtmSpvcDeletedNotify 3.1.1751.2.18.8.3.77
Info : Notification that TE SPVC configuration has been deleted. Return values - interfaceIndex - remote NSAP address
Status: current Access: read-write
NOTIFICATION-TYPE    

vbrAtmSpvcModifiedNotify 3.1.1751.2.18.8.3.78
Info : Notification that a SPVC endpoint has been modified - this trap has been obsoleted 07/01/2001.
Status: current Access: read-write
NOTIFICATION-TYPE    

vbrAtmSpvcModifyFailNotify 3.1.1751.2.18.8.3.79
Info : Notification that an attempt to modify a TE SPVC endpoint has failed - this trap has been obsoleted 07/01/2001.
Status: current Access: read-write
NOTIFICATION-TYPE    

virtualUNIIntfCreatedNotify 3.1.1751.2.18.8.3.80
Response to creation of Virtual UNI
Status: current Access: read-write
NOTIFICATION-TYPE    

virtualUNIIntfCreateFailNotify 3.1.1751.2.18.8.3.81
Info : Notification that an attempt to create an interface has failed. interfaceFailureReasonCode gives details.
Status: current Access: read-write
NOTIFICATION-TYPE    

virtualUNIIntfModifiedNotify 3.1.1751.2.18.8.3.82
Notification of a failure to modify a Virtual UNI interface.
Status: current Access: read-write
NOTIFICATION-TYPE    

virtualUNIIntfDeleteNotify 3.1.1751.2.18.8.3.83
Response to deletion of Virtual UNI
Status: current Access: read-write
NOTIFICATION-TYPE    

virtualUNIIntfModifyFailNotify 3.1.1751.2.18.8.3.84
Response to Modify Fail of Virtual UNI, Overload interfaceFailureReasonCode
Status: current Access: read-write
NOTIFICATION-TYPE    

virtualUNIIntfOutOfServiceNotify 3.1.1751.2.18.8.3.85
Notification of virtualUNI Out Of Service
Status: current Access: read-write
NOTIFICATION-TYPE    

virtualUNIIntfInServiceNotify 3.1.1751.2.18.8.3.86
Notification of virtualUNI in Service
Status: current Access: read-write
NOTIFICATION-TYPE    

gr303IgCreatedNotify 3.1.1751.2.18.8.3.87
Response to creation of GR303IG
Status: current Access: read-write
NOTIFICATION-TYPE    

gr303IgCreateFailNotify 3.1.1751.2.18.8.3.88
Info : Notification that an attempt to create a gr303 interface group has failed. interfaceFailureReasonCode gives details.
Status: current Access: read-write
NOTIFICATION-TYPE    

gr303IgModifiedNotify 3.1.1751.2.18.8.3.89
Response to modification of GR303IG
Status: current Access: read-write
NOTIFICATION-TYPE    

gr303IgDeleteNotify 3.1.1751.2.18.8.3.90
Response to deletion of GR303IG
Status: current Access: read-write
NOTIFICATION-TYPE    

gr303IgModifyFailNotify 3.1.1751.2.18.8.3.91
Response to Modify Fail of GR303IG, Overload interfaceFailureReasonCode
Status: current Access: read-write
NOTIFICATION-TYPE    

gr303IgOutOfServiceNotify 3.1.1751.2.18.8.3.92
Notification of GR303IG Out Of Service
Status: current Access: read-write
NOTIFICATION-TYPE    

gr303IgInServiceNotify 3.1.1751.2.18.8.3.93
Notification of GR303IG in Service
Status: current Access: read-write
NOTIFICATION-TYPE    

gr303IgIntfAddedNotify 3.1.1751.2.18.8.3.94
Response to addition of DS1 interface into GR303IG
Status: current Access: read-write
NOTIFICATION-TYPE    

gr303IgIntfAddFailNotify 3.1.1751.2.18.8.3.95
Info : Notification that an attempt to add an interface has failed. interfaceFailureReasonCode gives details.
Status: current Access: read-write
NOTIFICATION-TYPE    

gr303IgIntfDeleteNotify 3.1.1751.2.18.8.3.96
Response to deletion of DS1 interface from GR303IG
Status: current Access: read-write
NOTIFICATION-TYPE    

gr303TMCChanDownNotify 3.1.1751.2.18.8.3.97
Info : This trap indicates that TMC (LAPD) on the GR303 interface has gone down.
Status: current Access: read-write
NOTIFICATION-TYPE    

gr303EOCChanDownNotify 3.1.1751.2.18.8.3.98
Info : This trap indicates that EOC (LAPD) on the GR303 interface has gone down.
Status: current Access: read-write
NOTIFICATION-TYPE    

gr303TMCChanUpNotify 3.1.1751.2.18.8.3.99
Info : This trap indicates that TMC(LAPD) is functional on the specified GR303 interface.
Status: current Access: read-write
NOTIFICATION-TYPE    

gr303EOCChanUpNotify 3.1.1751.2.18.8.3.100
Info : This trap indicates that EOC(LAPD) is functional on the specified GR303 interface.
Status: current Access: read-write
NOTIFICATION-TYPE    

gr303PPSStateChangeNotify 3.1.1751.2.18.8.3.101
This indicates a change in the states of primary and secondary TMC/EOC (lapd)
Status: current Access: read-write
NOTIFICATION-TYPE    

gr303PPSSwitchoverNotify 3.1.1751.2.18.8.3.102
This notification is the result of PPS switching command which will indicate the reason code, initiator and states
Status: current Access: read-write
NOTIFICATION-TYPE    

gr303PPSCommandFailNotify 3.1.1751.2.18.8.3.103
This is the notification of failure of PPS switching command
Status: current Access: read-write
NOTIFICATION-TYPE    

interfaceBandwidthChangeNotify 3.1.1751.2.18.8.3.104
Info : Notification that a interface has undergone reduction in bandwidth. Critical depending on Failure Reason Code.
Status: current Access: read-write
NOTIFICATION-TYPE    

atmAtmSpvpConfiguredNotify 3.1.1751.2.18.8.3.105
Info : Notification that an ATM SPVP has been configured at the ATM SPVC endpoint. Return values - interfaceIndex - A-side vpi value - remote NSAP Address
Status: current Access: read-write
NOTIFICATION-TYPE    

atmAtmSpvpConfigFailNotify 3.1.1751.2.18.8.3.106
Info : Notification that an attempt to configure an ATM SPVP at the ATM SPVC endpoint has failed. Return values - interfaceIndex - A-side vpi value - remote NSAP Address - spvcConfigFailureCode: An identified reason for failure while configuring/modifying SPVC parameters.
Status: current Access: read-write
NOTIFICATION-TYPE    

atmAtmSpvpDeletedNotify 3.1.1751.2.18.8.3.107
Info : Notification that an ATM SPVP configuration has been deleted. Return values - interfaceIndex - A-side vpi value - remote NSAP Address
Status: current Access: read-write
NOTIFICATION-TYPE    

atmAtmSpvpModifiedNotify 3.1.1751.2.18.8.3.108
Info : Notification that an ATM SPVP configuration has been modified - this trap has been obsoleted 07/01/2001.
Status: current Access: read-write
NOTIFICATION-TYPE    

atmAtmSpvpModifyFailNotify 3.1.1751.2.18.8.3.109
Info : Notification that an attempt to modify a ATM SPVP configuration has failed - this trap has been obsoleted 07/01/2001.
Status: current Access: read-write
NOTIFICATION-TYPE    

atmTrunkingLocalIWFConfiguredNotify 3.1.1751.2.18.8.3.110
Info: Local IWF Configured return value: atmTrunkingIWFIdentifier
Status: current Access: read-write
NOTIFICATION-TYPE    

atmTrunkingLocalIWFConfigFailNotify 3.1.1751.2.18.8.3.111
Info: Local IWF Configured return value: atmTrunkingIWFIdentifier atmTrunkingConfigFailureCode
Status: current Access: read-write
NOTIFICATION-TYPE    

atmTrunkingLocalIWFModifiedNotify 3.1.1751.2.18.8.3.112
Info: configuration of Local IWF modified return value: atmTrunkingIWFIdentifier
Status: current Access: read-write
NOTIFICATION-TYPE    

atmTrunkingLocalIWFModifyFailNotify 3.1.1751.2.18.8.3.113
Info: Modification of Local IWF has failed return value: atmTrunkingIWFIdentifier atmTrunkingConfigFailureCode
Status: current Access: read-write
NOTIFICATION-TYPE    

atmTrunkingLocalIWFDeletedNotify 3.1.1751.2.18.8.3.114
Info: configuration of Local IWF deleted return value: atmTrunkingIWFIdentifier
Status: current Access: read-write
NOTIFICATION-TYPE    

atmTrunkingLocalIWFDeleteFailNotify 3.1.1751.2.18.8.3.115
Info: configuration of Local IWF can not be deleted return value: atmTrunkingIWFIdentifier atmTrunkingConfigFailureCode
Status: current Access: read-write
NOTIFICATION-TYPE    

atmTrunkingRemoteIWFConfiguredNotify 3.1.1751.2.18.8.3.116
Info : Notification that an ATM TRUNKING Remote IWF has been configured with return values - atmTrunkingRmtIWFIdentifier
Status: current Access: read-write
NOTIFICATION-TYPE    

atmTrunkingRemoteIWFConfigFailNotify 3.1.1751.2.18.8.3.117
Info : Notification that an ATM TRUNKING Remote IWF configuration has failed with return value : - atmTrunkingRmtIWFIdentifier - atmTrunkingConfigFailureCode
Status: current Access: read-write
NOTIFICATION-TYPE    

atmTrunkingRemoteIWFDeletedNotify 3.1.1751.2.18.8.3.118
Info : Notification that an ATM TRUNKING Remote IWF has been deleted with return values - atmTrunkingRmtIWFIdentifier
Status: current Access: read-write
NOTIFICATION-TYPE    

atmTrunkingRemoteIWFModifiedNotify 3.1.1751.2.18.8.3.119
Info : Notification that an ATM TRUNKING Remote IWF has been modified with return values - atmTrunkingRmtIWFIdentifier
Status: current Access: read-write
NOTIFICATION-TYPE    

atmTrunkingRemoteIWFModifyFailNotify 3.1.1751.2.18.8.3.120
Info : Notification that an ATM TRUNKING Remote IWF has been configured with return values - atmTrunkingRmtIWFIdentifier
Status: current Access: read-write
NOTIFICATION-TYPE    

atmTrunkingSigVccConfiguredNotify 3.1.1751.2.18.8.3.121
Info : Notification that an ATM TRUNKING Signalling VCC has been configured between Local IWF and with return values - atmTrunkingSigVccRmtIWFIdentifier - atmTrunkingSigVccIdentifier
Status: current Access: read-write
NOTIFICATION-TYPE    

atmTrunkingSigVccConfigFailNotify 3.1.1751.2.18.8.3.122
Info : Notification that an ATM TRUNKING Signalling VCC configuration has failed with return value: - atmTrunkingSigVccRmtIWFIdentifier - atmTrunkingSigVccIdentifier - atmTrunkingConfigFailureCode
Status: current Access: read-write
NOTIFICATION-TYPE    

atmTrunkingSigVccDeletedNotify 3.1.1751.2.18.8.3.123
Info : Notification that an ATM TRUNKING Signalling VCC has been deleted with return values - atmTrunkingSigVccRmtIWFIdentifier - atmTrunkingSigVccIdentifier
Status: current Access: read-write
NOTIFICATION-TYPE    

atmTrunkingBrVccConfiguredNotify 3.1.1751.2.18.8.3.124
Info : Notification that an ATM TRUNKING Bearer VCC has been configured between Local IWF and with return values - atmTrunkingBrVccRmtIWFIdentifier - atmTrunkingBrVccIdentifier
Status: current Access: read-write
NOTIFICATION-TYPE    

atmTrunkingBrVccConfigFailNotify 3.1.1751.2.18.8.3.125
Info : Notification that an ATM TRUNKING Bearer VCC configuration has failed with return value: - atmTrunkingBrVccRmtIWFIdentifier - atmTrunkingBrVccIdentifier - atmTrunkingConfigFailureCode
Status: current Access: read-write
NOTIFICATION-TYPE    

atmTrunkingBrVccDeletedNotify 3.1.1751.2.18.8.3.126
Info : Notification that an ATM TRUNKING Bearer VCC has been deleted with return values - atmTrunkingBrVccRmtIWFIdentifier - atmTrunkingBrVccIdentifier
Status: current Access: read-write
NOTIFICATION-TYPE    

atmPvcVccReqFailNotify 3.1.1751.2.18.8.4.1
Response : The PVC VCC connection request between two atm interfaces failed.
Status: current Access: read-write
NOTIFICATION-TYPE    

atmPvcVpcReqFailNotify 3.1.1751.2.18.8.4.2
Response : The PVC VPC connection request between two atm interfaces failed.
Status: current Access: read-write
NOTIFICATION-TYPE    

ipAtmAppPvcVccReqFailNotify 3.1.1751.2.18.8.4.3
Response : The PVC VCC connection request between in-band management and an atm interface has failed.
Status: current Access: read-write
NOTIFICATION-TYPE    

cirEmAtmPvcVccReqFailNotify 3.1.1751.2.18.8.4.4
Response : The PVC VCC connection request between a circuit emulation interface and an atm interface has failed.
Status: current Access: read-write
NOTIFICATION-TYPE    

vbrAtmPvcVccReqFailNotify 3.1.1751.2.18.8.4.5
Response : The PVC VCC connection request between a variable-bit rate interface and an atm interface has failed.
Status: current Access: read-write
NOTIFICATION-TYPE    

frAtmPvcVccReqFailNotify 3.1.1751.2.18.8.4.6
Response : The PVC VCC connection request between a frame-relay interface and an atm interface has failed.
Status: current Access: read-write
NOTIFICATION-TYPE    

frFrPvcReqFailNotify 3.1.1751.2.18.8.4.7
Response : The PVC connection request between two frame-relay interfaces has failed.
Status: current Access: read-write
NOTIFICATION-TYPE    

cirEmCirEmPvcReqFailNotify 3.1.1751.2.18.8.4.8
Response : The PVC connection request between two circuit emulation interfaces has failed.
Status: current Access: read-write
NOTIFICATION-TYPE    

vbrVbrPvcReqFailNotify 3.1.1751.2.18.8.4.9
Response : The PVC connection request between two variable-bit rate interfaces has failed.
Status: current Access: read-write
NOTIFICATION-TYPE    

atmPvcVccSetupNotify 3.1.1751.2.18.8.4.10
Response : The PVC VCC connection between two atm interfaces has been created.
Status: current Access: read-write
NOTIFICATION-TYPE    

atmPvcVpcSetupNotify 3.1.1751.2.18.8.4.11
Response : The PVC VPC connection between two atm interfaces has been created.
Status: current Access: read-write
NOTIFICATION-TYPE    

ipAtmAppPvcVccSetupNotify 3.1.1751.2.18.8.4.12
Response : The PVC VCC connection between in-band management and an atm interface has been created.
Status: current Access: read-write
NOTIFICATION-TYPE    

cirEmAtmPvcVccSetupNotify 3.1.1751.2.18.8.4.13
Response : The PVC VCC connection between a circuit emulation interface and an atm interface has been created.
Status: current Access: read-write
NOTIFICATION-TYPE    

vbrAtmPvcVccSetupNotify 3.1.1751.2.18.8.4.14
Response : The PVC VCC connection between a variable-bit rate interface and an atm interface has been created.
Status: current Access: read-write
NOTIFICATION-TYPE    

frAtmPvcVccSetupNotify 3.1.1751.2.18.8.4.15
Response : The PVC VCC connection between a frame-relay interface and an atm interface has been created.
Status: current Access: read-write
NOTIFICATION-TYPE    

frFrPvcSetupNotify 3.1.1751.2.18.8.4.16
Response : The PVC connection between two frame-relay interfaces has been created.
Status: current Access: read-write
NOTIFICATION-TYPE    

cirEmCirEmPvcSetupNotify 3.1.1751.2.18.8.4.17
Response : The PVC connection between two circuit-emulation interfaces has been created.
Status: current Access: read-write
NOTIFICATION-TYPE    

vbrVbrPvcSetupNotify 3.1.1751.2.18.8.4.18
Response : The PVC connection between two variable-bit rate interfaces has been created.
Status: current Access: read-write
NOTIFICATION-TYPE    

atmPvcVccTearDownNotify 3.1.1751.2.18.8.4.19
Response : The PVC VCC connection between two atm interfaces has been deleted.
Status: current Access: read-write
NOTIFICATION-TYPE    

atmPvcVpcTearDownNotify 3.1.1751.2.18.8.4.20
Response : The PVC VPC connection between two atm interfaces has been deleted.
Status: current Access: read-write
NOTIFICATION-TYPE    

ipAtmAppPvcVccTearDownNotify 3.1.1751.2.18.8.4.21
Response : The PVC VCC connection between in-band management and an atm interface has been deleted.
Status: current Access: read-write
NOTIFICATION-TYPE    

cirEmAtmPvcVccTearDownNotify 3.1.1751.2.18.8.4.22
Response : The PVC VCC connection between a circuit-emulation interface and an atm interface has been deleted.
Status: current Access: read-write
NOTIFICATION-TYPE    

vbrAtmPvcVccTearDownNotify 3.1.1751.2.18.8.4.23
Response : The PVC VCC connection between a variable-bit rate interface and an atm interface has been deleted.
Status: current Access: read-write
NOTIFICATION-TYPE    

frAtmPvcVccTearDownNotify 3.1.1751.2.18.8.4.24
Response : The PVC VCC connection between a frame-relay interface and an atm interface has been deleted.
Status: current Access: read-write
NOTIFICATION-TYPE    

frFrPvcTearDownNotify 3.1.1751.2.18.8.4.25
Response : The PVC connection between two frame-relay interfaces has been deleted.
Status: current Access: read-write
NOTIFICATION-TYPE    

cirEmCirEmPvcTearDownNotify 3.1.1751.2.18.8.4.26
Response : The PVC connection between two circuit-emulation interfaces has been deleted.
Status: current Access: read-write
NOTIFICATION-TYPE    

vbrVbrPvcTearDownNotify 3.1.1751.2.18.8.4.27
Response : The PVC connection between two variable-bit rate interfaces has been deleted.
Status: current Access: read-write
NOTIFICATION-TYPE    

bridgeBridgePvcReqFailNotify 3.1.1751.2.18.8.4.28
Response : The PVC connection request between two bridge interfaces has failed.
Status: current Access: read-write
NOTIFICATION-TYPE    

bridgeBridgePvcSetupNotify 3.1.1751.2.18.8.4.29
Response : The PVC connection between two bridge interfaces has been created.
Status: current Access: read-write
NOTIFICATION-TYPE    

bridgeBridgePvcTearDownNotify 3.1.1751.2.18.8.4.30
Response : The PVC connection between two bridge interfaces has been deleted.
Status: current Access: read-write
NOTIFICATION-TYPE    

bridgeAtmPvcVccReqFailNotify 3.1.1751.2.18.8.4.31
Response : The PVC VCC connection request between a bridge interface and an atm interface has failed.
Status: current Access: read-write
NOTIFICATION-TYPE    

bridgeAtmPvcVccSetupNotify 3.1.1751.2.18.8.4.32
Response : The PVC VCC connection between a bridge interface and an atm interface has been created.
Status: current Access: read-write
NOTIFICATION-TYPE    

bridgeAtmPvcVccTearDownNotify 3.1.1751.2.18.8.4.33
Response : The PVC VCC connection between a bridge interface and an atm interface has been deleted.
Status: current Access: read-write
NOTIFICATION-TYPE    

cellTestReqFailNotify 3.1.1751.2.18.8.4.34
Response : The PVC connection request has failed.
Status: current Access: read-write
NOTIFICATION-TYPE    

lmiDlciStatusNotify 3.1.1751.2.18.8.4.35
Response : Indicates the end-to-end status of the PVC of which this DLCI is a segment of.
Status: current Access: read-write
NOTIFICATION-TYPE    

cirEmAtmBkPvcVccReqFailNotify 3.1.1751.2.18.8.4.36
Response : The DHPVC VCC backup connection request between a circuit emulation interface and an atm interface has failed.
Status: current Access: read-write
NOTIFICATION-TYPE    

cirEmAtmBkPvcVccSetupNotify 3.1.1751.2.18.8.4.37
Response : The DHPVC VCC backup connection between a circuit emulation interface and an atm interface has been created.
Status: current Access: read-write
NOTIFICATION-TYPE    

cirEmAtmBkPvcVccTearDownNotify 3.1.1751.2.18.8.4.38
Response : The DHPVC VCC backup connection between a circuit-emulation interface and an atm interface has been deleted.
Status: current Access: read-write
NOTIFICATION-TYPE    

vbrAtmBkPvcVccReqFailNotify 3.1.1751.2.18.8.4.39
Response : The DHPVC VCC backup connection request between a variable-bit rate interface and an atm interface has failed.
Status: current Access: read-write
NOTIFICATION-TYPE    

vbrAtmBkPvcVccSetupNotify 3.1.1751.2.18.8.4.40
Response : The DHPVC VCC backup connection between a variable-bit rate interface and an atm interface has been created.
Status: current Access: read-write
NOTIFICATION-TYPE    

vbrAtmBkPvcVccTearDownNotify 3.1.1751.2.18.8.4.41
Response : The DHPVC VCC backup connection between a variable-bit rate interface and an atm interface has been deleted.
Status: current Access: read-write
NOTIFICATION-TYPE    

atmBkPvcVccReqFailNotify 3.1.1751.2.18.8.4.42
Response : The DHPVC VCC backup connection request between an atm interface and an atm interface has failed.
Status: current Access: read-write
NOTIFICATION-TYPE    

atmBkPvcVccSetupNotify 3.1.1751.2.18.8.4.43
Response : The DHPVC VCC backup connection between an atm interface and an atm interface has been created.
Status: current Access: read-write
NOTIFICATION-TYPE    

atmBkPvcVccTearDownNotify 3.1.1751.2.18.8.4.44
Response : The DHPVC VCC backup connection between an atm interface and an atm interface has been deleted.
Status: current Access: read-write
NOTIFICATION-TYPE    

frAtmBkPvcVccReqFailNotify 3.1.1751.2.18.8.4.45
Response : The DHPVC VCC backup connection request between a frame relay interface and an atm interface has failed.
Status: current Access: read-write
NOTIFICATION-TYPE    

frAtmBkPvcVccSetupNotify 3.1.1751.2.18.8.4.46
Response : The DHPVC VCC backup connection between a frame relay interface and an atm interface has been created.
Status: current Access: read-write
NOTIFICATION-TYPE    

frAtmBkPvcVccTearDownNotify 3.1.1751.2.18.8.4.47
Response : The DHPVC VCC backup connection between a frame relay interface and an atm interface has been deleted.
Status: current Access: read-write
NOTIFICATION-TYPE    

atmBkPvcVpcReqFailNotify 3.1.1751.2.18.8.4.48
Response : The DHPVC VPC backup connection request between an atm interface and an atm interface has failed.
Status: current Access: read-write
NOTIFICATION-TYPE    

atmBkPvcVpcSetupNotify 3.1.1751.2.18.8.4.49
Response : The DHPVC VPC backup connection between an atm interface and an atm interface has been created.
Status: current Access: read-write
NOTIFICATION-TYPE    

atmBkPvcVpcTearDownNotify 3.1.1751.2.18.8.4.50
Response : The DHPVC VPC backup connection between an atm interface and an atm interface has been deleted.
Status: current Access: read-write
NOTIFICATION-TYPE    

bridgeAtmBkPvcVccReqFailNotify 3.1.1751.2.18.8.4.51
Response : The DHPVC VCC backup connection request between a bridge interface and an atm interface has failed.
Status: current Access: read-write
NOTIFICATION-TYPE    

bridgeAtmBkPvcVccSetupNotify 3.1.1751.2.18.8.4.52
Response : The DHPVC VCC backup connection between a bridge interface and an atm interface has been created.
Status: current Access: read-write
NOTIFICATION-TYPE    

bridgeAtmBkPvcVccTearDownNotify 3.1.1751.2.18.8.4.53
Response : The DHPVC VCC backup connection between a bridge interface and an atm interface has been deleted.
Status: current Access: read-write
NOTIFICATION-TYPE    

ipAtmBkAppPvcVccReqFailNotify 3.1.1751.2.18.8.4.54
Response : The DHPVC VCC backup connection request between an in-band management interface and an atm interface has failed.
Status: current Access: read-write
NOTIFICATION-TYPE    

ipAtmBkAppPvcVccSetupNotify 3.1.1751.2.18.8.4.55
Response : The DHPVC VCC backup connection between an in-band management interface and an atm interface has been created.
Status: current Access: read-write
NOTIFICATION-TYPE    

ipAtmBkAppPvcVccTearDownNotify 3.1.1751.2.18.8.4.56
Response : The DHPVC VCC backup connection between an in-band management interface and an atm interface has been deleted.
Status: current Access: read-write
NOTIFICATION-TYPE    

cirEmAtmSpvcVccSetUpNotify 3.1.1751.2.18.8.4.57
Response : Notification that a SPVC connection between CE and ATM endpoints has been made successfully. Return values - A-side interfaceIndex B-side interfaceIndex B-side vpi/vci
Status: current Access: read-write
NOTIFICATION-TYPE    

vbrAtmSpvcVccSetUpNotify 3.1.1751.2.18.8.4.58
Response : Notification that a SPVC connection between TE and ATM endpoints has been made successfully. Return values - A-side interfaceIndex B-side interfaceIndex B-side vpi/vci
Status: current Access: read-write
NOTIFICATION-TYPE    

atmSpvcVccSetUpNotify 3.1.1751.2.18.8.4.59
Response : Notification that a SPVC connection between ATM and ATM endpoints has been made successfully. Return values - A-side interfaceIndex A-side vpi/vci B-side interfaceIndex B-side vpi/vci
Status: current Access: read-write
NOTIFICATION-TYPE    

cirEmAtmSpvcVccTearDownNotify 3.1.1751.2.18.8.4.60
Response : Notification that a SPVC connection between CE and ATM endpoints has been deleted. Return values - A-side interfaceIndex B-side interfaceIndex B-side vpi/vci
Status: current Access: read-write
NOTIFICATION-TYPE    

vbrAtmSpvcVccTearDownNotify 3.1.1751.2.18.8.4.61
Response : Notification that a SPVC connection between TE and ATM endpoints has been deleted. Return values - A-side interfaceIndex B-side interfaceIndex B-side vpi/vci
Status: current Access: read-write
NOTIFICATION-TYPE    

atmSpvcVccTearDownNotify 3.1.1751.2.18.8.4.62
Response : Notification that a SPVC connection between ATM and ATM endpoints has been deleted. Return values - A-side interfaceIndex A-side vpi/vci B-side interfaceIndex B-side vpi/vci
Status: current Access: read-write
NOTIFICATION-TYPE    

oamTestReqFailNotify 3.1.1751.2.18.8.4.63
Response : OAM loopback test request has failed.
Status: current Access: read-write
NOTIFICATION-TYPE    

oamActDeactResultNotify 3.1.1751.2.18.8.4.64
Response : the final status of oam Activation-Deactivation request.
Status: current Access: read-write
NOTIFICATION-TYPE    

frAtmSpvcVccSetUpNotify 3.1.1751.2.18.8.4.65
Response : Notification that a SPVC connection between FR and ATM endpoints has been made successfully. Return values - A-side interfaceIndex A-side dlci B-side interfaceIndex B-side vpi/vci
Status: current Access: read-write
NOTIFICATION-TYPE    

frAtmSpvcVccTearDownNotify 3.1.1751.2.18.8.4.66
Response : Notification that a SPVC connection between FR and ATM endpoints has been deleted. Return values - A-side interfaceIndex A-side dlci B-side interfaceIndex B-side vpi/vci
Status: current Access: read-write
NOTIFICATION-TYPE    

atmAtmSpvcVccSetUpNotify 3.1.1751.2.18.8.4.67
Response : Notification that a SPVC connection between ATM and ATM endpoints has been made successfully. Return values - A-side interfaceIndex A-side vpi/vci Remote NSAP address B-side interfaceIndex B-side vpi/vci
Status: current Access: read-write
NOTIFICATION-TYPE    

atmAtmSpvcVccTearDownNotify 3.1.1751.2.18.8.4.68
Response : Notification that a SPVC connection between ATM and ATM endpoints has been deleted. Return values - A-side interfaceIndex A-side vpi/vci Remote NSAP address B-side interfaceIndex B-side vpi/vci
Status: current Access: read-write
NOTIFICATION-TYPE    

cirAtmSpvcVccSetUpNotify 3.1.1751.2.18.8.4.69
Response : Notification that a SPVC connection between CE and ATM endpoints has been made successfully. Return values - A-side interfaceIndex Remote NSAP address B-side interfaceIndex B-side vpi/vci
Status: current Access: read-write
NOTIFICATION-TYPE    

cirAtmSpvcVccTearDownNotify 3.1.1751.2.18.8.4.70
Response : Notification that a SPVC connection between CE and ATM endpoints has been deleted. Return values - A-side interfaceIndex Remote NSAP address B-side interfaceIndex B-side vpi/vci
Status: current Access: read-write
NOTIFICATION-TYPE    

vbrAtmSpvcSetUpNotify 3.1.1751.2.18.8.4.71
Response : Notification that a SPVC connection between TE and ATM endpoints has been made successfully. Return values - A-side interfaceIndex Remote NSAP address B-side interfaceIndex B-side vpi/vci
Status: current Access: read-write
NOTIFICATION-TYPE    

vbrAtmSpvcTearDownNotify 3.1.1751.2.18.8.4.72
Response : Notification that a SPVC connection between TE and ATM endpoints has been deleted. Return values - A-side interfaceIndex Remote NSAP address B-side interfaceIndex B-side vpi/vci
Status: current Access: read-write
NOTIFICATION-TYPE    

aal2TrunkConfigSetupNotify 3.1.1751.2.18.8.4.73
Response : The PVC VCC connection for aal2 trunk
Status: current Access: read-write
NOTIFICATION-TYPE    

aal2TrunkConfigTearDownNotify 3.1.1751.2.18.8.4.74
Response : The PVC VCC AAL2 Trunk has been deleted
Status: current Access: read-write
NOTIFICATION-TYPE    

aal2TrunkConfigReqFailNotify 3.1.1751.2.18.8.4.75
Response : The PVC VCC aal2 trunk could not be setup
Status: current Access: read-write
NOTIFICATION-TYPE    

gr303Aal2PvcConfigReqFailNotify 3.1.1751.2.18.8.4.76
Response : The GR303 PVC VCC on aal2 trunk could not be setup
Status: current Access: read-write
NOTIFICATION-TYPE    

gr303Aal2PvcSetUpNotify 3.1.1751.2.18.8.4.77
Response : Notification that a monitor connection between Gr303 call ref and ATM AAL2 CID has been made successfully.
Status: current Access: read-write
NOTIFICATION-TYPE    

gr303Aal2PvcTearDownNotify 3.1.1751.2.18.8.4.78
Response : Notification that a monitor connection between Gr303 call ref and ATM AAL2 CID has been deleted
Status: current Access: read-write
NOTIFICATION-TYPE    

dhpvcChangeNotify 3.1.1751.2.18.8.4.79
This will indicate the changes in a dual home pvc. This will have 2 indications. One is when there is a switchover which indicate the last state and the new one (eg Prim To Bkup) Secondly there will also be an indication when there is a state change which will indicate the new state only (eg Primary is Active and in No Fail Condition and Backup is Passive and in Fail Condition). In case of state change the traffic path is not changed but it indicates the state of the passive path.
Status: current Access: read-write
NOTIFICATION-TYPE    

atmAtmSpvcVpcSetUpNotify 3.1.1751.2.18.8.4.80
Response : Notification that a SPVP connection between ATM and ATM endpoints has been made successfully.
Status: current Access: read-write
NOTIFICATION-TYPE    

atmAtmSpvcVpcTearDownNotify 3.1.1751.2.18.8.4.81
Response : Notification that a SPVP connection between ATM and ATM endpoints has been deleted.
Status: current Access: read-write
NOTIFICATION-TYPE    

iptResultNotify 3.1.1751.2.18.8.4.82
Response : the final status of interface protection request.
Status: current Access: read-write
NOTIFICATION-TYPE    

pgtResultNotify 3.1.1751.2.18.8.4.83
Response : the final status of interface protection group request.
Status: current Access: read-write
NOTIFICATION-TYPE    

atmTrunkingSigVccSetUpNotify 3.1.1751.2.18.8.4.84
Response : Notification that a ATM Trunking Signalling VCC has been setup successfully. Return values - atmTrunkingSigVccRmtIWFIdentifier atmTrunkingSigVccIdentifier
Status: current Access: read-write
NOTIFICATION-TYPE    

atmTrunkingSigVccTearDownNotify 3.1.1751.2.18.8.4.85
Response : Notification that a ATM Trunking Signalling VCC has been torn down successfully. Return values - atmTrunkingSigVccRmtIWFIdentifier atmTrunkingSigVccIdentifier
Status: current Access: read-write
NOTIFICATION-TYPE    

atmTrunkingBrVccSetUpNotify 3.1.1751.2.18.8.4.86
Response : Notification that a ATM Trunking Bearer VCC has been setup successfully. Return values - atmTrunkingBrVccRmtIWFIdentifier atmTrunkingBrVccIdentifier
Status: current Access: read-write
NOTIFICATION-TYPE    

atmTrunkingBrVccTearDownNotify 3.1.1751.2.18.8.4.87
Response : Notification that a ATM Trunking Bearer VCC has been torn down successfully. Return values - atmTrunkingBrVccRmtIWFIdentifier atmTrunkingBrVccIdentifier
Status: current Access: read-write
NOTIFICATION-TYPE