ADTRAN-AOS-POWER

File: ADTRAN-AOS-POWER.mib (10546 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
ADTRAN-AOS

Imported symbols

Unsigned32 OBJECT-TYPE MODULE-IDENTITY
NOTIFICATION-TYPE TruthValue TEXTUAL-CONVENTION
MODULE-COMPLIANCE OBJECT-GROUP NOTIFICATION-GROUP
adGenAOSPower adGenAOSConformance

Defined Types

AdEpsPowerDeliveryStateTC  
Indicates Failure State of a power supply
TEXTUAL-CONVENTION    
  INTEGER delivering(1), notDelivering(2), failed(3), unknown(4)  

AdRpsPowerDeliveryStateTC  
Indicates Failure State of a power supply
TEXTUAL-CONVENTION    
  INTEGER failed(1), busy(2), delivering(3), available(4), unknown(5)  

AdPowerConnectionStateTC  
Indicates Failure State of a power supply
TEXTUAL-CONVENTION    
  INTEGER connected(1), notConnected(2), notApplicable(3), unknown(4)  

AdGenAOSPowerEpsRpsEntry  
SEQUENCE    
  adGenAOSPowerEpsRpsInstanceId Unsigned32
  adGenAOSPowerEpsConnectionState AdPowerConnectionStateTC
  adGenAOSPowerEpsDeliveryState AdEpsPowerDeliveryStateTC
  adGenAOSPowerRpsConnectionState AdPowerConnectionStateTC
  adGenAOSPowerRpsDeliveryState AdRpsPowerDeliveryStateTC

Defined Values

adGenAOSPowerMonitor 1.3.6.1.4.1.664.5.53.7.1
The MIB module for general configuration of power monitoring options for devices with battery backup.
MODULE-IDENTITY    

adGenAOSPowerTraps 1.3.6.1.4.1.664.5.53.7.0
OBJECT IDENTIFIER    

adGenAOSPowerRollOverCtl 1.3.6.1.4.1.664.5.53.7.1.1
OBJECT IDENTIFIER    

adGenAOSPowerEpsRps 1.3.6.1.4.1.664.5.53.7.1.2
OBJECT IDENTIFIER    

adGenAOSPowerRolloverOnAC 1.3.6.1.4.1.664.5.53.7.1.1.1
Integer value specifying whether or not unit is on AC power.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

adGenAOSPwrRollOvrEvntSecSinceEpoch 1.3.6.1.4.1.664.5.53.7.1.1.2
The time (seconds since epoch) that a power rollover trap was generated.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Unsigned32  

adGenAOSPowerEpsRpsTable 1.3.6.1.4.1.664.5.53.7.1.2.1
EPS/RPS Power Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AdGenAOSPowerEpsRpsEntry

adGenAOSPowerEpsRpsEntry 1.3.6.1.4.1.664.5.53.7.1.2.1.1
EPS/RPS entry for a particular VCID.
Status: current Access: not-accessible
OBJECT-TYPE    
  AdGenAOSPowerEpsRpsEntry  

adGenAOSPowerEpsRpsInstanceId 1.3.6.1.4.1.664.5.53.7.1.2.1.1.1
Uniquely identifies a row in the adGenAOSEpsRpsTable.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

adGenAOSPowerEpsConnectionState 1.3.6.1.4.1.664.5.53.7.1.2.1.1.2
Text value specifying if an EPS is connected or not.
Status: current Access: read-only
OBJECT-TYPE    
  AdPowerConnectionStateTC  

adGenAOSPowerEpsDeliveryState 1.3.6.1.4.1.664.5.53.7.1.2.1.1.3
Text value specifying the delivery state of the EPS power.
Status: current Access: read-only
OBJECT-TYPE    
  AdEpsPowerDeliveryStateTC  

adGenAOSPowerRpsConnectionState 1.3.6.1.4.1.664.5.53.7.1.2.1.1.4
Text value specifying if an RPS is connected or not.
Status: current Access: read-only
OBJECT-TYPE    
  AdPowerConnectionStateTC  

adGenAOSPowerRpsDeliveryState 1.3.6.1.4.1.664.5.53.7.1.2.1.1.5
Text value specifying the delivery state of the RPS power.
Status: current Access: read-only
OBJECT-TYPE    
  AdRpsPowerDeliveryStateTC  

adGenAOSPowerRollover 1.3.6.1.4.1.664.5.53.7.0.1
This trap indicates the unit has had a change in power source, either from AC to DC or back again. The SecSinceEpoch represents the time (seconds since epoch) that the rollover occured.
Status: current Access: read-only
NOTIFICATION-TYPE    

adGenAOSEpsConnectionChange 1.3.6.1.4.1.664.5.53.7.0.2
This trap indicates the unit has had a change in the EPS connection state.
Status: current Access: read-only
NOTIFICATION-TYPE    

adGenAOSEpsDeliveryChange 1.3.6.1.4.1.664.5.53.7.0.3
This trap indicates the unit has had a change in the EPS delivery state.
Status: current Access: read-only
NOTIFICATION-TYPE    

adGenAOSRpsConnectionChange 1.3.6.1.4.1.664.5.53.7.0.4
This trap indicates the unit has had a change in the RPS connection state.
Status: current Access: read-only
NOTIFICATION-TYPE    

adGenAOSRpsDeliveryChange 1.3.6.1.4.1.664.5.53.7.0.5
This trap indicates the unit has had a change in the RPS delivery state.
Status: current Access: read-only
NOTIFICATION-TYPE    

adGenAOSPowerConformance 1.3.6.1.4.1.664.5.53.99.11
OBJECT IDENTIFIER    

adGenAOSPowerGroups 1.3.6.1.4.1.664.5.53.99.11.1
OBJECT IDENTIFIER    

adGenAOSPowerCompliances 1.3.6.1.4.1.664.5.53.99.11.2
OBJECT IDENTIFIER    

adGenAOSPowerFullCompliance 1.3.6.1.4.1.664.5.53.99.11.2.1
The compliance statement for SNMP entities which implement version 2 of the adGenAOSPower MIB. When this MIB is fully implemented, then such an implementation can claim full compliance.
Status: current Access: read-only
MODULE-COMPLIANCE    

adGenAOSPowerNotificationGroup 1.3.6.1.4.1.664.5.53.99.11.1.1
Trap which may be used to enhance power event driven management of the Unit.
Status: current Access: read-only
NOTIFICATION-GROUP    

adGenAOSPowerRollOverCtlGroup 1.3.6.1.4.1.664.5.53.99.11.1.2
The Unit SNMP Config Group.
Status: current Access: read-only
OBJECT-GROUP    

adGenAOSEpsNotificationGroup 1.3.6.1.4.1.664.5.53.99.11.1.3
Trap used to indicate state changes of EPS.
Status: current Access: read-only
NOTIFICATION-GROUP    

adGenAOSRpsNotificationGroup 1.3.6.1.4.1.664.5.53.99.11.1.4
Trap used to indicate state changes of RPS.
Status: current Access: read-only
NOTIFICATION-GROUP    

adGenAOSEpsRpsConfigurationGroup 1.3.6.1.4.1.664.5.53.99.11.1.5
The Unit SNMP Config Group.
Status: current Access: read-only
OBJECT-GROUP