AIX1-MIB

File: AIX1-MIB.mib (81226 bytes)

Imported modules

SNMPv2-TC SNMPv2-SMI

Imported symbols

DisplayString MODULE-IDENTITY OBJECT-TYPE
Counter32 Integer32 enterprises

Defined Types

IfIndexType  
INTEGER 1..2147483647    

ApplAdminEntry  
SEQUENCE    
  aix1ApplAdminIndex IfIndexType
  aix1ApplAdminLinkStart INTEGER
  aix1ApplAdminLinkMode INTEGER
  aix1ApplAdminResetErrs INTEGER
  aix1ApplAdminXONXOFFProto INTEGER
  aix1ApplAdminNMAProto INTEGER
  aix1ApplAdminOPSINEProto INTEGER
  aix1ApplAdminTL1Proto INTEGER
  aix1ApplAdminLinkDescription DisplayString
  aix1ApplAdminLinkConnectionMode INTEGER

ApplOperEntry  
SEQUENCE    
  aix1ApplOperIndex IfIndexType
  aix1ApplOperLinkMode INTEGER
  aix1ApplOperXONXOFFProto INTEGER
  aix1ApplOperNMAProto INTEGER
  aix1ApplOperOPSINEProto INTEGER
  aix1ApplOperTL1Proto INTEGER
  aix1ApplOperLinkDescription DisplayString
  aix1ApplOperLinkConnectionMode INTEGER

PktAdminEntry  
SEQUENCE    
  aix1PktAdminIndex IfIndexType
  aix1PktAdminConformanceMode INTEGER
  aix1PktAdminDBit INTEGER
  aix1PktAdminQBitMBit INTEGER
  aix1PktAdminUseRejectPkts INTEGER
  aix1PktAdminSendInitialRestart INTEGER
  aix1PktAdminStdsBody INTEGER
  aix1PktAdminFacilChecking INTEGER
  aix1PktAdminUndefinedFacils INTEGER
  aix1PktAdminDefMaxPktSize INTEGER
  aix1PktAdminDefWindowSize INTEGER
  aix1PktAdminNegMaxPktSize INTEGER
  aix1PktAdminNegWindowSize INTEGER
  aix1PktAdminPacketizingTimer INTEGER
  aix1PktAdminPVCOffset INTEGER
  aix1PktAdminSVCOffset INTEGER

PktOperEntry  
SEQUENCE    
  aix1PktOperIndex IfIndexType
  aix1PktOperConformanceMode INTEGER
  aix1PktOperDBit INTEGER
  aix1PktOperQBitMBit INTEGER
  aix1PktOperUseRejectPkts INTEGER
  aix1PktOperSendInitialRestart INTEGER
  aix1PktOperStdsBody INTEGER
  aix1PktOperFacilChecking INTEGER
  aix1PktOperUndefinedFacils INTEGER
  aix1PktOperDefMaxPktSize INTEGER
  aix1PktOperDefWindowSize INTEGER
  aix1PktOperNegMaxPktSize INTEGER
  aix1PktOperNegWindowSize INTEGER
  aix1PktOperPacketizingTimer INTEGER
  aix1PktOperPVCOffset INTEGER
  aix1PktOperSVCOffset INTEGER

PktStatEntry  
SEQUENCE    
  aix1PktStatIndex IfIndexType
  aix1PktStatInCharsPerSec80s Counter32
  aix1PktStatOutCharsPerSec80s Counter32

FrmAdminEntry  
SEQUENCE    
  aix1FrmAdminIndex IfIndexType
  aix1FrmAdminIdleRRs INTEGER
  aix1FrmAdminRandomizeT1 INTEGER

FrmOperEntry  
SEQUENCE    
  aix1FrmOperIndex IfIndexType
  aix1FrmOperIdleRRs INTEGER
  aix1FrmOperRandomizeT1 INTEGER

PhysAdminEntry  
SEQUENCE    
  aix1PhysAdminIndex IfIndexType
  aix1PhysAdminInterFrameDelayStatus INTEGER
  aix1PhysAdminInterFrameDelayInterval INTEGER
  aix1PhysAdminT1LineBuildOut INTEGER

PhysOperEntry  
SEQUENCE    
  aix1PhysOperIndex IfIndexType
  aix1PhysOperInterFrameDelayStatus INTEGER
  aix1PhysOperInterFrameDelayInterval INTEGER
  aix1PhysOperT1LineBuildOut INTEGER

PhysStatEntry  
SEQUENCE    
  aix1PhysStatIndex IfIndexType
  aix1PhysStatTxAborts Counter32

CircuitEntry  
SEQUENCE    
  aix1CircuitLinkId IfIndexType
  aix1CircuitChannelNumber INTEGER
  aix1CircuitState INTEGER
  aix1CircuitConType INTEGER
  aix1CircuitBCNumber INTEGER
  aix1CircuitUserData DisplayString
  aix1CircuitRemoteBasePort INTEGER
  aix1CircuitRemoteVCNumber INTEGER
  aix1CircuitPktsSent Counter32
  aix1CircuitPktsRcvd Counter32
  aix1CircuitOperPVCType INTEGER
  aix1CircuitOperPVCTimer INTEGER

VCEntry  
SEQUENCE    
  aix1VCVCNumber INTEGER 0..287
  aix1VCState INTEGER
  aix1VCConType INTEGER
  aix1VCBCNumber INTEGER
  aix1VCUserData DisplayString
  aix1VCRemoteBasePort INTEGER
  aix1VCRemoteVCNumber INTEGER
  aix1VCPktsSent Counter32
  aix1VCPktsRcvd Counter32
  aix1VCOperPVCType INTEGER
  aix1VCOperPVCTimer INTEGER

AdminPVCEntry  
SEQUENCE    
  aix1AdminPVCLinkId IfIndexType
  aix1AdminPVCChannelNumber INTEGER
  aix1AdminPVCType INTEGER
  aix1AdminPVCTimer INTEGER

Defined Values

aii 1.3.6.1.4.1.539
OBJECT IDENTIFIER    

aiSystemOID 1.3.6.1.4.1.539.2
OBJECT IDENTIFIER    

aiX1 1.3.6.1.4.1.539.12
OBJECT IDENTIFIER    

aiX1System 1.3.6.1.4.1.539.12.1
OBJECT IDENTIFIER    

aiX1Appl 1.3.6.1.4.1.539.12.2
OBJECT IDENTIFIER    

aiX1Pkt 1.3.6.1.4.1.539.12.3
OBJECT IDENTIFIER    

aiX1Frm 1.3.6.1.4.1.539.12.4
OBJECT IDENTIFIER    

aiX1Phys 1.3.6.1.4.1.539.12.5
OBJECT IDENTIFIER    

aiX1VC 1.3.6.1.4.1.539.12.6
OBJECT IDENTIFIER    

ai192 1.3.6.1.4.1.539.2.192
OBJECT IDENTIFIER    

ai192Ver7 1.3.6.1.4.1.539.2.192.7
OBJECT IDENTIFIER    

ai192Ver70 1.3.6.1.4.1.539.2.192.7.0
OBJECT IDENTIFIER    

ai192Ver708 1.3.6.1.4.1.539.2.192.7.0.8
OBJECT IDENTIFIER    

ai192Ver709 1.3.6.1.4.1.539.2.192.7.0.9
OBJECT IDENTIFIER    

ai192Ver71 1.3.6.1.4.1.539.2.192.7.1
OBJECT IDENTIFIER    

ai192Ver710 1.3.6.1.4.1.539.2.192.7.1.0
OBJECT IDENTIFIER    

ai192Ver711 1.3.6.1.4.1.539.2.192.7.1.1
OBJECT IDENTIFIER    

ai192Ver72 1.3.6.1.4.1.539.2.192.7.2
OBJECT IDENTIFIER    

ai192Ver720 1.3.6.1.4.1.539.2.192.7.2.0
OBJECT IDENTIFIER    

ai192Ver721 1.3.6.1.4.1.539.2.192.7.2.1
OBJECT IDENTIFIER    

ai192Ver77 1.3.6.1.4.1.539.2.192.7.7
OBJECT IDENTIFIER    

ai196 1.3.6.1.4.1.539.2.196
OBJECT IDENTIFIER    

ai196Ver7 1.3.6.1.4.1.539.2.196.7
OBJECT IDENTIFIER    

ai196Ver70 1.3.6.1.4.1.539.2.196.7.0
OBJECT IDENTIFIER    

ai196Ver708 1.3.6.1.4.1.539.2.196.7.0.8
OBJECT IDENTIFIER    

ai196Ver709 1.3.6.1.4.1.539.2.196.7.0.9
OBJECT IDENTIFIER    

ai196Ver71 1.3.6.1.4.1.539.2.196.7.1
OBJECT IDENTIFIER    

ai196Ver710 1.3.6.1.4.1.539.2.196.7.1.0
OBJECT IDENTIFIER    

ai196Ver711 1.3.6.1.4.1.539.2.196.7.1.1
OBJECT IDENTIFIER    

ai196Ver72 1.3.6.1.4.1.539.2.196.7.2
OBJECT IDENTIFIER    

ai196Ver720 1.3.6.1.4.1.539.2.196.7.2.0
OBJECT IDENTIFIER    

ai196Ver721 1.3.6.1.4.1.539.2.196.7.2.1
OBJECT IDENTIFIER    

ai196Ver77 1.3.6.1.4.1.539.2.196.7.7
OBJECT IDENTIFIER    

aix1AdminGbufXoffThreshold 1.3.6.1.4.1.539.12.1.1
The configured XOFF global flow control threshold. If zero and if aix1AdminGbufRecovThreshold is zero, the global flow control mechanism is disabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..ffff  

aix1AdminGbufRecovThreshold 1.3.6.1.4.1.539.12.1.2
The configured recovery global flow control threshold. If zero and if aix1AdminGbufXoffThreshold is zero, the global flow control mechanism is disabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..ffff  

aix1AdminRollover 1.3.6.1.4.1.539.12.1.3
This object has been depricated and remains in the MIB for backward compatibility.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ready(1), roll(2)  

aix1Bx25AdminCallDown 1.3.6.1.4.1.539.12.1.4
If set to off(2), an active BX.25 link will stay up after all calls are disconnected. If set to on(1), an active BX.25 link will drop and go into DMLOCK (see aix1Bx25AdminDMlock below) when all the link's backplane connections are terminated. This object is meaningful only when aix1ApplOperLinkMode is set to passive(2) on a given packet layer entity.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2)  

aix1Bx25AdminDMlock 1.3.6.1.4.1.539.12.1.5
The number of seconds to wait after a BX.25 passive link has gone inactive before allowing an outgoing call to attempt to bring up the link. Any outgoing call attempts will be rejected until the DMLOCK timer expires and the passive link returns to the standby mode. This object is meaningful only when aix1ApplOperLinkMode is set to passive(2) on a given packet layer entity.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 25..ffffffff  

aix1Bx25AdminLinkUp 1.3.6.1.4.1.539.12.1.6
The number of seconds to wait for a passive link to become active. This object is meaningful only when aix1ApplOperLinkMode is set to passive(2) on a given packet layer entity.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 5..ffffffff  

aix1StatErrX25InData 1.3.6.1.4.1.539.12.1.7
Number of data bytes from X.25 which were lost due to buffer failures.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

aix1StatErrX25OutData 1.3.6.1.4.1.539.12.1.8
Number of data bytes from the FIFO which were discarded due to buffer failures.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

aix1StatErrX25OutPkt 1.3.6.1.4.1.539.12.1.9
Number of messages from X.25 to GCOM which were lost due to some kind of resource failure in the GCOM library.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

aix1StatErrX25OutChoked 1.3.6.1.4.1.539.12.1.10
Number of times a port has received a flow control stop message from GCOM(or perhaps from X.25), and thus entered the Choked state. This may not be indicative of a serious problem, but may also mean that data has been lost.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

aix1StatErrPlogCount 1.3.6.1.4.1.539.12.1.11
Number of times an internal error routine has been called due to unexpected packets received from GCOM ( or X.25).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

aix1StatErrGfctlXoffs 1.3.6.1.4.1.539.12.1.12
Number of times the global flow control mechanism attempted to back pressure data flow from the backplane.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

aix1StatErrGfctlDiscards 1.3.6.1.4.1.539.12.1.13
Number of times the global flow control mechanism has detected a buffer level so low that it discarded data received from the backplane.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

aix1StatErrUwteBadTrans 1.3.6.1.4.1.539.12.1.14
Number of unified window transactions with bad transaction codes received from CLC or a remote SLC. If this counter is non-zero, it indicated the presence of incompatible versions of firmware on the SLC and CLC, or a bug in either the SLC or CLC firmware.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

aix1StatErrUwteBadFlds 1.3.6.1.4.1.539.12.1.15
Number of invalid fields received in unified window transactions. If this counter is non-zero, it indicates the presence of incompatible versions or a bug in either the SLC or CLC firmware.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

aix1StatErrUwteMissingFlds 1.3.6.1.4.1.539.12.1.16
Number of required fields absent from received unified window transactions. If this counter is non-zero, it indicates the presence of incompatible versions or a bug in either the SLC or CLC firmware.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

aix1StatErrLogOutLost 1.3.6.1.4.1.539.12.1.17
Number of outbound log messages discarded to avoid flooding the log. This arises because the SLC is attempting to generate log messages too frequently on a particular TDS or globally. When this occurs, the SLC will discard the log message and increment the counter. This is not a serious error, and typically occurs during periods of intense, repetitive logging activity.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

aix1StatErrVcMuxErrs 1.3.6.1.4.1.539.12.1.18
Number of serious multiplexing errors which have occurred. Such an error generally involves an impossible value in an internal header or receipt of a message on the wrong internal channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

aix1StatErrEmptyPktsRcv 1.3.6.1.4.1.539.12.1.19
Number of empty data packets received from the network.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

aix1StatInCharsPerSec80s 1.3.6.1.4.1.539.12.1.20
The average number of data characters (characters in the data field of X.25 data packets) received from the network per second over the last 80 seconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

aix1StatOutCharsPerSec80s 1.3.6.1.4.1.539.12.1.21
The average number of data characters (characters in the data field of X.25 data packets) transmitted to the network per second over the last 80 seconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

aix1ApplAdminTable 1.3.6.1.4.1.539.12.2.1
The table of administrative elements which apply to an individual X.25 link above the packet layer.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ApplAdminEntry

aix1ApplAdminEntry 1.3.6.1.4.1.539.12.2.1.1
The addressing information for one of this X.25 link's administrative objects.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ApplAdminEntry  

aix1ApplAdminIndex 1.3.6.1.4.1.539.12.2.1.1.1
The ifIndex value of the packet layer entity associated with these application level objects.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IfIndexType  

aix1ApplAdminLinkStart 1.3.6.1.4.1.539.12.2.1.1.2
Start or stop a link that's enabled by the standard MIB link status objects. If the link is not enabled by the standard MIB objects, a write to this object will have no effect. Stopping a link by writing to this object does not free significant resources, it just stops activity on the link.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER started(1), stopped(2)  

aix1ApplAdminLinkMode 1.3.6.1.4.1.539.12.2.1.1.3
Determines whether link behaves as a normal X.25 link or a BX.25-style passive link. This is the most recently configured value of this attribute, and may not yet have taken effect. The current operating value is available as aix1ApplOperLinkMode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), passive(2)  

aix1ApplAdminResetErrs 1.3.6.1.4.1.539.12.2.1.1.4
Writing the value resetCounters(2) to this object resets the per-link level 1 error counters. No other writes are accepted. They are aix1PhysStatRxCRCErrors, aix1PhysStatRxAborts, aix1PhysStatRxOverruns, aix1PhysStatTxAborts, aix1PhysStatTxUnderruns.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ready(1), resetCounters(2)  

aix1ApplAdminXONXOFFProto 1.3.6.1.4.1.539.12.2.1.1.5
Determines whether XON/XOFF protocol processing is in effect by default on all virtual circuits on the link.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2)  

aix1ApplAdminNMAProto 1.3.6.1.4.1.539.12.2.1.1.6
Determines whether NMA protocol processing is in effect by default on all virtual circuits on the link.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2)  

aix1ApplAdminOPSINEProto 1.3.6.1.4.1.539.12.2.1.1.7
Determines whether OPSINE protocol processing is in effect by default on all virtual circuits on the link.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2)  

aix1ApplAdminTL1Proto 1.3.6.1.4.1.539.12.2.1.1.8
Determines whether TL1 protocol processing is in effect by default on all virtual circuits on the link.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2)  

aix1ApplAdminLinkDescription 1.3.6.1.4.1.539.12.2.1.1.9
A descriptive string associated with this link. This provides a place for the agent to supply any descriptive information about the use or owner of the link. A zero length value indicates that the agent doesn't have any additional information.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..50)  

aix1ApplAdminLinkConnectionMode 1.3.6.1.4.1.539.12.2.1.1.10
Connect or disconnect a link that's enabled by the standard MIB linmk status objects. If the link is not enabled by the standard MIB objects, a write to this object will have no effect. Disconnecting a link by writing to this object does not free any resources, it marks the link as not connected, so that the link will not cause a level 4 (LINKDOWN) alarm to be generated.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER connected(1), disconnected(2), disabled(4)  

aix1ApplOperTable 1.3.6.1.4.1.539.12.2.2
The table of operational elements which apply to an individual X.25 link above the packet layer.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ApplOperEntry

aix1ApplOperEntry 1.3.6.1.4.1.539.12.2.2.1
The addressing information for one of this X.25 link's operational objects.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ApplOperEntry  

aix1ApplOperIndex 1.3.6.1.4.1.539.12.2.2.1.1
The ifIndex value of the packet level associated with these application level objects.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IfIndexType  

aix1ApplOperLinkMode 1.3.6.1.4.1.539.12.2.2.1.2
Determines whether link behaves as a normal X.25 link or a BX.25-style passive link. This is the mandatory operating value of this attribute. The most recently configured value is available as aix1ApplAdminLinkMode.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), passive(2)  

aix1ApplOperXONXOFFProto 1.3.6.1.4.1.539.12.2.2.1.3
Determines whether XON/XOFF protocol processing is in effect by default on all virtual circuits on the link.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

aix1ApplOperNMAProto 1.3.6.1.4.1.539.12.2.2.1.4
Determines whether NMA protocol processing is in effect by default on all virtual circuits on the link.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

aix1ApplOperOPSINEProto 1.3.6.1.4.1.539.12.2.2.1.6
Determines whether OPSINE protocol processing is in effect by default on all virtual circuits on the link.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

aix1ApplOperTL1Proto 1.3.6.1.4.1.539.12.2.2.1.7
Determines whether TL1 protocol processing is in effect by default on all virtual circuits on the link.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

aix1ApplOperLinkDescription 1.3.6.1.4.1.539.12.2.2.1.8
A descriptive string associated with this link. This provides a place for the agent to supply any descriptive information about the use or owner of the link. A zero length value indicates that the agent doesn't have any additional information.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..50)  

aix1ApplOperLinkConnectionMode 1.3.6.1.4.1.539.12.2.2.1.9
Determines whether the link is currently disconnected, connected or has been reconnected after it was disconnected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER connected(1), disconnected(2), reconnected(3), disabled(4), linkdown(5), linkup(6)  

aix1PktAdminTable 1.3.6.1.4.1.539.12.3.1
The table of administrative elements which apply to an individual X.25 link at the packet layer.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PktAdminEntry

aix1PktAdminEntry 1.3.6.1.4.1.539.12.3.1.1
The addressing information for one of this X.25 link's packet layer administrative objects.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PktAdminEntry  

aix1PktAdminIndex 1.3.6.1.4.1.539.12.3.1.1.1
The ifIndex value of the packet layer entity associated with these objects.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IfIndexType  

aix1PktAdminConformanceMode 1.3.6.1.4.1.539.12.3.1.1.2
The configured conformance testing mode to which X.25's behavior will adhere. This value may not have taken effect. The value with which the SLC is currently operating is the value of aix1OperConformanceMode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ccitt(1), ddn(2)  

aix1PktAdminDBit 1.3.6.1.4.1.539.12.3.1.1.3
Determines whether the packet level will allow the D-bit in call setup packets.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dbitNotAllowed(1), dbitAllowed(2)  

aix1PktAdminQBitMBit 1.3.6.1.4.1.539.12.3.1.1.4
Determines whether the packet level will check for consistency in the use of Q and M bits, i. e. that the value of the Q-bit is the same in every packet of an M-bit sequence.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noQMCheck(1), qmCheck(2)  

aix1PktAdminUseRejectPkts 1.3.6.1.4.1.539.12.3.1.1.5
Enables and disables the use of packet retransmission. If the packet level is acting as a DTE it will send a REJ packet in response to a data packet received out of sequence. If the packet level is acting as a DCE, it will accept a REJ packet and retransmit the requested data packet(s).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noPktRetrans(1), pktRetrans(2)  

aix1PktAdminSendInitialRestart 1.3.6.1.4.1.539.12.3.1.1.6
Enables and disables sending of an initial restart request packet when the link comes up.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER initialRestart(1), noInitialRestart(2)  

aix1PktAdminStdsBody 1.3.6.1.4.1.539.12.3.1.1.7
Selects between ISO and CCITT packet level specifications.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ccittPktLvl(1), isoPktLvl(2)  

aix1PktAdminFacilChecking 1.3.6.1.4.1.539.12.3.1.1.8
Enables and disables packet level checking of the facilities field of call processing packets for validity.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER checkFacils(1), noCheckFacils(2)  

aix1PktAdminUndefinedFacils 1.3.6.1.4.1.539.12.3.1.1.9
Enables and disables packet level allowing undefined facilities to appear in the facilities field of call processing packets.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noUndefFacils(1), undefFacils(2)  

aix1PktAdminDefMaxPktSize 1.3.6.1.4.1.539.12.3.1.1.10
The maximum packet size to use for all calls placed on this packet layer entity. If aix1PktAdminNegPktSize is set to negotiate(2), this will be the proposed value for calls placed on the packet level entitry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER pkt128(128), pkt256(256), pkt512(512), pkt1024(1024)  

aix1PktAdminDefWindowSize 1.3.6.1.4.1.539.12.3.1.1.11
The maximum packet level window size to use on this PLE. If aix1PktAdminNegWindowSize is set to negotiate(2), this will be the proposed value for calls placed on the packet layer entity.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..127  

aix1PktAdminNegMaxPktSize 1.3.6.1.4.1.539.12.3.1.1.12
Determines whether this PLE will originate calls which negotiate packet size.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noNegotiation(1), negotiate(2)  

aix1PktAdminNegWindowSize 1.3.6.1.4.1.539.12.3.1.1.13
Determines whether this PLE will originate calls which negotiate window size.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noNegotiation(1), negotiate(2)  

aix1PktAdminPacketizingTimer 1.3.6.1.4.1.539.12.3.1.1.14
The interval from the time of receipt of the first character from the TDM backplane to transmission of a block of characters to the X.25 protocol stack for transmission in a data packet to the network. In 100ths of a second. This value is not meaningful on backplane connections on which escape framing, TL1 packetizing, or programmable forwarding characters are active.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

aix1PktAdminPVCOffset 1.3.6.1.4.1.539.12.3.1.1.15
Specifies an offset that gets added to the PVC logical channel range specified by x25AdmnMaxActiveCircuits and x25AdmnNumberPVCs from RFC 1382.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

aix1PktAdminSVCOffset 1.3.6.1.4.1.539.12.3.1.1.16
Specifies an offset that gets added to the SVC logical channel range specified by x25AdmnMaxActiveCircuits and x25AdmnNumberPVCs from RFC 1382.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

aix1PktOperTable 1.3.6.1.4.1.539.12.3.2
The table of operational elements which apply to an individual X.25 link at the packet layer.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PktOperEntry

aix1PktOperEntry 1.3.6.1.4.1.539.12.3.2.1
The addressing information for one of this X.25 link's packet layer operational objects.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PktOperEntry  

aix1PktOperIndex 1.3.6.1.4.1.539.12.3.2.1.1
The ifIndex value of the packet level associated with these objects.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IfIndexType  

aix1PktOperConformanceMode 1.3.6.1.4.1.539.12.3.2.1.2
The conformance testing mode to which X.25's behavior will adhere. This is the currently operational value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ccitt(1), ddn(2)  

aix1PktOperDBit 1.3.6.1.4.1.539.12.3.2.1.3
Determines whether the packet level will allow the D-bit in call setup packets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER dbitNotAllowed(1), dbitAllowed(2)  

aix1PktOperQBitMBit 1.3.6.1.4.1.539.12.3.2.1.4
Determines whether the packet level will check for consistency in the use of Q and M bits, i. e. that the value of the Q-bit is the same in every packet of an M-bit sequence.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noQMCheck(1), qmCheck(2)  

aix1PktOperUseRejectPkts 1.3.6.1.4.1.539.12.3.2.1.5
Enables and disables the use of packet retransmission. If the packet level is acting as a DTE it will send a REJ packet in response to a data packet received out of sequence. If the packet level is acting as a DCE, it will accept a REJ packet and retransmit the requested data packet(s).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noPktRetrans(1), pktRetrans(2)  

aix1PktOperSendInitialRestart 1.3.6.1.4.1.539.12.3.2.1.6
Enables and disables sending of an initial restart request packet when the link comes up.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER initialRestart(1), noInitialRestart(2)  

aix1PktOperStdsBody 1.3.6.1.4.1.539.12.3.2.1.7
Selects between ISO and CCITT packet level specifications.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ccittPktLvl(1), isoPktLvl(2)  

aix1PktOperFacilChecking 1.3.6.1.4.1.539.12.3.2.1.8
Enables and disables packet level checking of the facilities field of call processing packets for validity.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER checkFacils(1), noCheckFacils(2)  

aix1PktOperUndefinedFacils 1.3.6.1.4.1.539.12.3.2.1.9
Enables and disables packet level allowing undefined facilities to appear in the facilities field of call processing packets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noUndefFacils(1), undefFacils(2)  

aix1PktOperDefMaxPktSize 1.3.6.1.4.1.539.12.3.2.1.10
The maximum packet size to use for all calls placed on this packet layer entity. If aix1PktOperNegPktSize is set to negotiate(2), this will be the proposed value for calls placed on the packett layer entity.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER pkt128(128), pkt256(256), pkt512(512), pkt1024(1024)  

aix1PktOperDefWindowSize 1.3.6.1.4.1.539.12.3.2.1.11
The maximum packet level window size to use for all calls placed on this packet layer entity. If aix1PktOperNegWindowSize is set to negotiate(2), this will be the proposed value for calls placed on the packet layer entity.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..127  

aix1PktOperNegMaxPktSize 1.3.6.1.4.1.539.12.3.2.1.12
Determines whether this packet layer entity will originate calls which negotiate packet size.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noNegotiation(1), negotiate(2)  

aix1PktOperNegWindowSize 1.3.6.1.4.1.539.12.3.2.1.13
Determines whether this packet layer entity will originate calls which negotiate window size.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noNegotiation(1), negotiate(2)  

aix1PktOperPacketizingTimer 1.3.6.1.4.1.539.12.3.2.1.14
The interval from the time of receipt of the first character from the TDM backplane to transmission of a block of characters to the X.25 protocol stack for transmission in a data packet to the network. In 100ths of a second. This value is not meaningful on backplane connections on which escape framing, TL1 packetizing, or programmable forwarding characters are active.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

aix1PktOperPVCOffset 1.3.6.1.4.1.539.12.3.2.1.15
Specifies an offset that gets added to the PVC logical channel range specified by x25AdmnMaxActiveCircuits and x25AdmnNumberPVCs from RFC 1382.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..4095  

aix1PktOperSVCOffset 1.3.6.1.4.1.539.12.3.2.1.16
Specifies an offset that gets added to the SVC logical channel range specified by x25AdmnMaxActiveCircuits and x25AdmnNumberPVCs from RFC 1382.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..4095  

aix1PktStatTable 1.3.6.1.4.1.539.12.3.3
The table of statistical elements which apply to an individual X.25 link at the packet layer.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PktStatEntry

aix1PktStatEntry 1.3.6.1.4.1.539.12.3.3.1
The addressing information for one of this X.25 link's packet layer statistical objects.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PktStatEntry  

aix1PktStatIndex 1.3.6.1.4.1.539.12.3.3.1.1
The ifIndex value of the packet layer entity associated with these objects.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IfIndexType  

aix1PktStatInCharsPerSec80s 1.3.6.1.4.1.539.12.3.3.1.2
The average number of data characters (characters in the data field of X.25 data packets) received from the network per second over the last 80 seconds by this packet layer entity.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

aix1PktStatOutCharsPerSec80s 1.3.6.1.4.1.539.12.3.3.1.3
The average number of data characters (characters in the data field of X.25 data packets) transmitted to the network per second over the last 80 seconds by this packet layer entity.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

aix1FrmAdminTable 1.3.6.1.4.1.539.12.4.1
The table of administrative elements which apply to an individual X.25 link at the frame layer.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FrmAdminEntry

aix1FrmAdminEntry 1.3.6.1.4.1.539.12.4.1.1
The addressing information for one of this X.25 link's frame layer administrative objects.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FrmAdminEntry  

aix1FrmAdminIndex 1.3.6.1.4.1.539.12.4.1.1.1
The ifIndex value of the frame layer entity associated with these objects.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IfIndexType  

aix1FrmAdminIdleRRs 1.3.6.1.4.1.539.12.4.1.1.2
Enables and disables transmission of idle Receive Ready frames by the frame layer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER idleRRs(1), noIdleRRs(2)  

aix1FrmAdminRandomizeT1 1.3.6.1.4.1.539.12.4.1.1.3
Enables and disables the introduction of random jitter into the frame layer's T1 timer to avoid T1 timer synchronization with the remote frame layer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER randomT1(1), noRandomT1(2)  

aix1FrmOperTable 1.3.6.1.4.1.539.12.4.2
The table of operational elements which apply to an individual X.25 link at the frame layer.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FrmOperEntry

aix1FrmOperEntry 1.3.6.1.4.1.539.12.4.2.1
The addressing information for one of this X.25 link's frame layer operational objects.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FrmOperEntry  

aix1FrmOperIndex 1.3.6.1.4.1.539.12.4.2.1.1
The ifIndex value of the frame level associated with these objects.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IfIndexType  

aix1FrmOperIdleRRs 1.3.6.1.4.1.539.12.4.2.1.2
Enables and disables transmission of idle Receive Ready frames by the frame layer.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER idleRRs(1), noIdleRRs(2)  

aix1FrmOperRandomizeT1 1.3.6.1.4.1.539.12.4.2.1.3
Enables and disables the introduction of random jitter into the frame layer's T1 timer to avoid T1 timer synchronization with the remote frame layer.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER randomT1(1), noRandomT1(2)  

aix1PhysAdminTable 1.3.6.1.4.1.539.12.5.1
The table of administrative elements which apply to an individual X.25 link at the physical layer.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PhysAdminEntry

aix1PhysAdminEntry 1.3.6.1.4.1.539.12.5.1.1
The addressing information for one of this X.25 link's physical layer administrative objects.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PhysAdminEntry  

aix1PhysAdminIndex 1.3.6.1.4.1.539.12.5.1.1.1
The ifIndex value of the physical port associated with these objects.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IfIndexType  

aix1PhysAdminInterFrameDelayStatus 1.3.6.1.4.1.539.12.5.1.1.2
Enables and disables a delay period between transmitted frames.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ifdDisabled(1), ifdEnabled(2)  

aix1PhysAdminInterFrameDelayInterval 1.3.6.1.4.1.539.12.5.1.1.3
Sets the interframe delay interval. This value is effective only if aix1PhysAdminInterFrameDelayStatus is set to ifdEnabled(2). This value is expressed in microseconds, with 100 microsecond granularity (it's truncated to the nearest 100 microseconds).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..7fffffff  

aix1PhysAdminT1LineBuildOut 1.3.6.1.4.1.539.12.5.1.1.4
The T1 line build out value. The specified syntax represents ranges of line length expressed in feet.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER lbo0to133(1), lbo133to266(2), lbo266to399(3), lbo399to533(4), lbo533to655(5)  

aix1PhysOperTable 1.3.6.1.4.1.539.12.5.2
The table of operational elements which apply to an individual X.25 link at the physical layer.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PhysOperEntry

aix1PhysOperEntry 1.3.6.1.4.1.539.12.5.2.1
The addressing information for one of this X.25 link's physical layer operational objects.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PhysOperEntry  

aix1PhysOperIndex 1.3.6.1.4.1.539.12.5.2.1.1
The ifIndex value of the physical port associated with these objects.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IfIndexType  

aix1PhysOperInterFrameDelayStatus 1.3.6.1.4.1.539.12.5.2.1.2
Enables and disables a delay period between transmitted frames.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ifdDisabled(1), ifdEnabled(2)  

aix1PhysOperInterFrameDelayInterval 1.3.6.1.4.1.539.12.5.2.1.3
Sets the interframe delay interval. This value is effective only if aix1PhysAdminInterFrameDelayStatus is set to ifdEnabled(2). This value is expressed in microseconds, with 100 microsecond granularity (it's truncated to the nearest 100 microseconds).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..7fffffff  

aix1PhysOperT1LineBuildOut 1.3.6.1.4.1.539.12.5.2.1.4
The T1 line build out value. The specified syntax represents ranges of line length expressed in feet.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER lbo0to133(1), lbo133to266(2), lbo266to399(3), lbo399to533(4), lbo533to655(5)  

aix1PhysStatTable 1.3.6.1.4.1.539.12.5.3
The table of statistical elements which apply to an individual X.25 link at the physical layer.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PhysStatEntry

aix1PhysStatEntry 1.3.6.1.4.1.539.12.5.3.1
The addressing information for one of this X.25 link's physical layer statistical objects.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PhysStatEntry  

aix1PhysStatIndex 1.3.6.1.4.1.539.12.5.3.1.1
The ifIndex value of the physical port associated with these objects.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IfIndexType  

aix1PhysStatTxAborts 1.3.6.1.4.1.539.12.5.3.1.2
The number of abort sequences transmitted on the serial interfaces. This is a proprietary object because the RS232-like MIB (RFC 1659) doesn't define a similar object! RFC 1659 defines a counter for receive aborts, but not transmit aborts.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

aix1CircuitTable 1.3.6.1.4.1.539.12.6.1
The table of objects which maps logical channel number and packet level ifIndex number to Virtual Connection(VC) number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CircuitEntry

aix1CircuitEntry 1.3.6.1.4.1.539.12.6.1.1
The addressing information for the VC Circuit table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CircuitEntry  

aix1CircuitLinkId 1.3.6.1.4.1.539.12.6.1.1.1
The ifindex value of the packet layer entity.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IfIndexType  

aix1CircuitChannelNumber 1.3.6.1.4.1.539.12.6.1.1.2
X.25 logical channel number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..4095  

aix1CircuitState 1.3.6.1.4.1.539.12.6.1.1.3
The call processing state of the local Virtual Connection. This is not a standard packet level state. This is the call processing state of the AI version 7 system firmware that mediates between the X.25 protocol stack and AISwitch internal connection mechanisms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER idle(1), active(2), csCall(3), csDisco(4), csCancel(5), csReject(6), csCol(7), csUncol(8), npCall(9), npDisco(10), npCancel(11), npReject(12), npCol(13), npUncol(14), trapped(15), csSuspend(16)  

aix1CircuitConType 1.3.6.1.4.1.539.12.6.1.1.4
The type of connection currently supported by the VC.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER lmux(1), rmux(2), debug(5), background(6), pvc(11), svc(12)  

aix1CircuitBCNumber 1.3.6.1.4.1.539.12.6.1.1.5
The number of the Bus Connection with which this VC is associated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..31  

aix1CircuitUserData 1.3.6.1.4.1.539.12.6.1.1.6
The user data that was sent or received in the call request.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..16)  

aix1CircuitRemoteBasePort 1.3.6.1.4.1.539.12.6.1.1.7
The baseport of the card to which the SLC is connected across the backplane. This value is meaningful only when this VC is multiplexed to the other SLC. If not, the value returned is -1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER -1..256  

aix1CircuitRemoteVCNumber 1.3.6.1.4.1.539.12.6.1.1.8
The Virtual Connection number of the VC on the remote SLC to which this VC is connected. This value is meaningful only on multiplexed VCs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..ffff  

aix1CircuitPktsSent 1.3.6.1.4.1.539.12.6.1.1.9
The number of packets sent to the packet level by the AI version 7 system software. This counts all kinds of packets, not just data packets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

aix1CircuitPktsRcvd 1.3.6.1.4.1.539.12.6.1.1.10
The number of packets received from the packet level by the AI version 7 system software. This counts all kinds of packets, not just data packets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

aix1CircuitOperPVCType 1.3.6.1.4.1.539.12.6.1.1.11
Defines the relationship between a PVC and the connection-oriented AISwitch TDM backplane. The three types represented are defined as follows: Active: initiates connections across the backplane at an interval defined by the timer. Passive: waits to respond to a connection attempt across the backplane. Uses timer to wait for reset confirm from network. Accepts backplane connection if it receives reset confirmation in time. Connect on Activity: initiates connection across backplane upon the receipt of data from the network. Forwards received data once connection is established. Disconnects backplane connection if a timer interval passes with no data activity in either direction. This object will return the value none(1) if the value of aix1CircuitConType for this VC is not pvc(11). This object reflects the current operational value of this parameter. Note that unlike most operational objects, it is writable. If the value of this object is changed, it modifies the current behavior of the board, but is not saved in nonvolatile memory.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), active(2), connectOnActivity(3), passive(4)  

aix1CircuitOperPVCTimer 1.3.6.1.4.1.539.12.6.1.1.12
Defines the timer interval, in seconds used to manage the PVC's relationship with an internal backplane connection. The timer is used for different purposes depending on the value of aix1VCPVCType as described above. This object will return the value 0 if the VC in question is not associated with a PVC. This object reflects the current operational value of this parameter. Note that unlike most operational objects, it is writable. If the value of this object is changed, it modifies the current behavior of the board, but is not saved in nonvolatile memory.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..600  

aix1VCTable 1.3.6.1.4.1.539.12.6.2
The table of objects containing information pertaining to Virtual Connections(VC).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VCEntry

aix1VCEntry 1.3.6.1.4.1.539.12.6.2.1
The addressing information for the VC table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VCEntry  

aix1VCVCNumber 1.3.6.1.4.1.539.12.6.2.1.1
The local Virtual Connection number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..287  

aix1VCState 1.3.6.1.4.1.539.12.6.2.1.2
The call processing state of the local Virtual Connection. This is not a standard packet level state. This is the call call processing state of the AI version 7 system firmware that mediates between the X.25 protocol stack and AISwitch internal connection mechanisms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER idle(1), active(2), csCall(3), csDisco(4), csCancel(5), csReject(6), csCol(7), csUncol(8), npCall(9), npDisco(10), npCancel(11), npReject(12), npCol(13), npUncol(14), trapped(15), csSuspend(16)  

aix1VCConType 1.3.6.1.4.1.539.12.6.2.1.3
The type of connection currently supported by the VC.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER lmux(1), rmux(2), debug(5), background(6), pvc(11), svc(12)  

aix1VCBCNumber 1.3.6.1.4.1.539.12.6.2.1.4
The number of the Bus Connection with which this VC is associated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..31  

aix1VCUserData 1.3.6.1.4.1.539.12.6.2.1.5
The user data that was sent or received in the call request.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..16)  

aix1VCRemoteBasePort 1.3.6.1.4.1.539.12.6.2.1.6
The baseport of the card to which the SLC is connected across the backplane. This value is meaningful only when this VC is multiplexed to the other SLC. If not, the value returned is -1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER -1..256  

aix1VCRemoteVCNumber 1.3.6.1.4.1.539.12.6.2.1.7
The Virtual Connection number of the VC on the remote SLC to which this VC is connected. This value is meaningful only on multiplexed VCs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..ffff  

aix1VCPktsSent 1.3.6.1.4.1.539.12.6.2.1.8
The number of packets sent to the packet level by the AI version 7 system software. This counts all kinds of packets, not just data packets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

aix1VCPktsRcvd 1.3.6.1.4.1.539.12.6.2.1.9
The number of packets received from the packet level by the AI version 7 system software. This counts all kinds of packets, not just data packets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

aix1VCOperPVCType 1.3.6.1.4.1.539.12.6.2.1.10
Defines the relationship between a PVC and the connection-oriented AISwitch TDM backplane. The three types represented are defined as follows: Active: initiates connections across the backplane at an interval defined by the timer. Passive: waits to respond to a connection attempt across the backplane. Uses timer to wait for reset confirm from network. Accepts backplane connection if it receives reset confirmation in time. Connect on Activity: initiates connection across backplane upon receipt of data from network. Forwards received data once connection is established. Disconnects backplane connection if a timer interval passes with no data activity in either direction. This object will return the value none(1) if the value of aix1VCConType for this VC is not pvc(11). This object reflects the current operational value of this parameter. Note that unlike most operational objects, it is writable. If the value of this object is changed, it modifies the current behavior of the board, but is not saved in nonvolatile memory.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), active(2), connectOnActivity(3), passive(4)  

aix1VCOperPVCTimer 1.3.6.1.4.1.539.12.6.2.1.11
Defines the timer interval, in seconds used to manage the PVC's relationship with an internal backplane connection. The timer is used for different purposes depending on the value of aix1VCPVCType as described above. This object will return the value 0 if the VC in question question is not associated with a PVC. This object reflects the current operational value of this parameter. Note that unlike most operational objects, it is writable. If the value of this object is changed, it modifies the current behavior of the board, but is not saved in nonvolatile memory.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..600  

aix1AdminPVCTable 1.3.6.1.4.1.539.12.6.3
The table of objects which control attributes of PVCs configured, but not necessarily in effect.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AdminPVCEntry

aix1AdminPVCEntry 1.3.6.1.4.1.539.12.6.3.1
The addressing information for the PVC Admin table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AdminPVCEntry  

aix1AdminPVCLinkId 1.3.6.1.4.1.539.12.6.3.1.1
The ifindex value of the packet layer entity.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IfIndexType  

aix1AdminPVCChannelNumber 1.3.6.1.4.1.539.12.6.3.1.2
X.25 logical channel number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..4095  

aix1AdminPVCType 1.3.6.1.4.1.539.12.6.3.1.3
Defines the relationship between a PVC and the connection-oriented AISwitch TDM backplane. The three types represent are defined as follows: Active: initiates connections across the backplane at an interval defined by the timer. Passive: waits to respond to a connection attempt across the backplane. Uses timer to wait for reset confirm from network. Accepts the backplane connection if it receives reset confirmation in time. Connect on Activity: initiates connection across backplane upon receipt of data from network. Forwards received data once connection is established. Disconnects backplane connection if a timer interval passes with no data activity in either direction. This object will return the value none(1) if aix1AdminPVCChannelNumber doesn't correspond to a channel in the range specified by the combination of x25admnNumberPVCs and aix1PktAdminPVCOffset for the link specified by aix1AdminPVCLinkID. This object is settable, but does not reflect the mandatory operational value of this parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), active(2), connectOnActivity(3), passive(4)  

aix1AdminPVCTimer 1.3.6.1.4.1.539.12.6.3.1.4
Defines the timer interval, in seconds used to manage the PVC's relationship with an internal backplane connection. The timer is used for different purposes depending on the value of aix1VCPVCType as described above. This object will return the value 0 if aix1AdminPVCChannelNumber doesn't correspond to a channel in the range specified by the combination of x25admnNumberPVCs and aix1PktAdminPVCOffset for the link specified by aix1AdminPVCLinkID. This object is settable, but does not reflect the mandatory operational value of this parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..600