ALTIGA-HARDWARE-STATS-MIB

File: ALTIGA-HARDWARE-STATS-MIB.mib (22898 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
ALTIGA-MIB ALTIGA-GLOBAL-REG

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Integer32
Gauge32 Counter32 TimeTicks
Unsigned32 DisplayString TruthValue
TEXTUAL-CONVENTION OBJECT-GROUP MODULE-COMPLIANCE
alStatsHardware alHardwareGroup alHardwareMibModule

Defined Types

ConcentratorCard  
Concentrator Card Type.
TEXTUAL-CONVENTION    
  INTEGER none(1), sep(2), dualT1Wan(3), sepE(4)  

ConcentratorType  
Concentrator Type indicates the chassis type.
TEXTUAL-CONVENTION    
  INTEGER cxx(1), c5(2), c1(3)  

Defined Values

altigaHardwareStatsMibModule 1.3.6.1.4.1.3076.1.1.27.2
The Altiga Hardware Statistics MIB models counters and objects that are of management interest for the hardware. Acronyms The following acronyms are used in this document: CPU: Central Processing Unit MB: Megabyte MIB: Management Information Base PS: Power Supply RPM: Revolutions Per Minute SEP: Scalable Encryption Processor WAN: Wide Area Network
MODULE-IDENTITY    

alStatsHardwareGlobal 1.3.6.1.4.1.3076.2.1.2.22.1
OBJECT IDENTIFIER    

alHardwareCpuVoltage 1.3.6.1.4.1.3076.2.1.2.22.1.1
The current CPU voltage in centivolts.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

alHardwareCpuVoltageAlarm 1.3.6.1.4.1.3076.2.1.2.22.1.2
The alarm status for CPU voltage. This alarm will fired when the CPU voltage is detected out of configured range.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

alHardwareCpuVoltageCount 1.3.6.1.4.1.3076.2.1.2.22.1.3
The number of alarm events for CPU voltage.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

alHardwareCpuVoltageTime 1.3.6.1.4.1.3076.2.1.2.22.1.4
The sysUptime at the time of the last change of alarm status for CPU voltage.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

alHardwarePs1Voltage3v 1.3.6.1.4.1.3076.2.1.2.22.1.5
The current 3V voltage of Power Supply 1 in centivolts.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

alHardwarePs1Voltage3vAlarm 1.3.6.1.4.1.3076.2.1.2.22.1.6
The alarm status for PS1 3v voltage. This alarm will fired when the 3v power supply 1 voltage is detected out of configured range.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

alHardwarePs1Voltage3vCount 1.3.6.1.4.1.3076.2.1.2.22.1.7
The number of alarm events for PS1 3v voltage.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

alHardwarePs1Voltage3vTime 1.3.6.1.4.1.3076.2.1.2.22.1.8
The sysUptime at the time of the last change of alarm status for PS1 3v voltage.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

alHardwarePs1Voltage5v 1.3.6.1.4.1.3076.2.1.2.22.1.9
The current 5V voltage of Power Supply 1 in centivolts.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

alHardwarePs1Voltage5vAlarm 1.3.6.1.4.1.3076.2.1.2.22.1.10
The alarm status for PS1 5v voltage. This alarm will fired when the 5v power supply 1 voltage is detected out of configured range.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

alHardwarePs1Voltage5vCount 1.3.6.1.4.1.3076.2.1.2.22.1.11
The number of alarm events for PS1 5v voltage.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

alHardwarePs1Voltage5vTime 1.3.6.1.4.1.3076.2.1.2.22.1.12
The sysUptime at the time of the last change of alarm status for PS1 5v voltage.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

alHardwarePs2Voltage3v 1.3.6.1.4.1.3076.2.1.2.22.1.13
The current 3V voltage of Power Supply 2 in centivolts.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

alHardwarePs2Voltage3vAlarm 1.3.6.1.4.1.3076.2.1.2.22.1.14
The alarm status for PS2 3v voltage. This alarm will fired when the 3v power supply 2 voltage is detected out of configured range.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

alHardwarePs2Voltage3vCount 1.3.6.1.4.1.3076.2.1.2.22.1.15
The number of alarm events for PS2 3v voltage.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

alHardwarePs2Voltage3vTime 1.3.6.1.4.1.3076.2.1.2.22.1.16
The sysUptime at the time of the last change of alarm status for PS2 3v voltage.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

alHardwarePs2Voltage5v 1.3.6.1.4.1.3076.2.1.2.22.1.17
The current 5V voltage of Power Supply 2 in centivolts.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

alHardwarePs2Voltage5vAlarm 1.3.6.1.4.1.3076.2.1.2.22.1.18
The alarm status for PS2 5v voltage. This alarm will fired when the 5v power supply 2 voltage is detected out of configured range.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

alHardwarePs2Voltage5vCount 1.3.6.1.4.1.3076.2.1.2.22.1.19
The number of alarm events for PS2 5v voltage.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

alHardwarePs2Voltage5vTime 1.3.6.1.4.1.3076.2.1.2.22.1.20
The sysUptime at the time of the last change of alarm status for PS2 5v voltage.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

alHardwareBoardVoltage3v 1.3.6.1.4.1.3076.2.1.2.22.1.21
The current 3V voltage of the mainboard in centivolts.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

alHardwareBoardVoltage3vAlarm 1.3.6.1.4.1.3076.2.1.2.22.1.22
The alarm status for the mainboard 3v voltage. This alarm will fired when the 3v mainboard voltage is detected out of configured range.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

alHardwareBoardVoltage3vCount 1.3.6.1.4.1.3076.2.1.2.22.1.23
The number of alarm events for the mainboard 3v voltage.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

alHardwareBoardVoltage3vTime 1.3.6.1.4.1.3076.2.1.2.22.1.24
The sysUptime at the time of the last change of alarm status for the mainboard 3v voltage.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

alHardwareBoardVoltage5v 1.3.6.1.4.1.3076.2.1.2.22.1.25
The current 5V voltage of the mainboard in centivolts.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

alHardwareBoardVoltage5vAlarm 1.3.6.1.4.1.3076.2.1.2.22.1.26
The alarm status for the mainboard 5v voltage. This alarm will fired when the 5v mainboard voltage is detected out of configured range.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

alHardwareBoardVoltage5vCount 1.3.6.1.4.1.3076.2.1.2.22.1.27
The number of alarm events for the mainboard 5v voltage.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

alHardwareBoardVoltage5vTime 1.3.6.1.4.1.3076.2.1.2.22.1.28
The sysUptime at the time of the last change of alarm status for the mainboard 5v voltage.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

alHardwareCpuTemp 1.3.6.1.4.1.3076.2.1.2.22.1.29
The current CPU temperature in degrees C.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -40..120  

alHardwareCpuTempAlarm 1.3.6.1.4.1.3076.2.1.2.22.1.30
The alarm status for the CPU temperature. This alarm will fired when the CPU temperature is detected out of configured range.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

alHardwareCpuTempCount 1.3.6.1.4.1.3076.2.1.2.22.1.31
The number of alarm events for the CPU temperature.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

alHardwareCpuTempTime 1.3.6.1.4.1.3076.2.1.2.22.1.32
The sysUptime at the time of the last change of alarm status for the CPU temperature.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

alHardwareCageTemp 1.3.6.1.4.1.3076.2.1.2.22.1.33
The current cage temperature in degrees C.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -40..120  

alHardwareCageTempAlarm 1.3.6.1.4.1.3076.2.1.2.22.1.34
The alarm status for the cage temperature. This alarm will fired when the cage temperature is detected out of configured range.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

alHardwareCageTempCount 1.3.6.1.4.1.3076.2.1.2.22.1.35
The number of alarm events for the cage temperature.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

alHardwareCageTempTime 1.3.6.1.4.1.3076.2.1.2.22.1.36
The sysUptime at the time of the last change of alarm status for the cage temperature.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

alHardwareFan1Rpm 1.3.6.1.4.1.3076.2.1.2.22.1.37
The current speed of fan 1 in RPM.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

alHardwareFan1RpmAlarm 1.3.6.1.4.1.3076.2.1.2.22.1.38
The alarm status for fan 1 RPM. This alarm will fired when fan 1 RPM is detected out of configured range.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

alHardwareFan1RpmCount 1.3.6.1.4.1.3076.2.1.2.22.1.39
The number of alarm events for fan 1 RPM.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

alHardwareFan1RpmTime 1.3.6.1.4.1.3076.2.1.2.22.1.40
The sysUptime at the time of the last change of alarm status for fan 1 RPM.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

alHardwareFan2Rpm 1.3.6.1.4.1.3076.2.1.2.22.1.41
The current speed of fan 2 in RPM.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

alHardwareFan2RpmAlarm 1.3.6.1.4.1.3076.2.1.2.22.1.42
The alarm status for fan 2 RPM. This alarm will fired when fan 2 RPM is detected out of configured range.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

alHardwareFan2RpmCount 1.3.6.1.4.1.3076.2.1.2.22.1.43
The number of alarm events for fan 2 RPM.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

alHardwareFan2RpmTime 1.3.6.1.4.1.3076.2.1.2.22.1.44
The sysUptime at the time of the last change of alarm status for fan 2 RPM.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

alHardwareFan3Rpm 1.3.6.1.4.1.3076.2.1.2.22.1.45
The current speed of fan 3 in RPM.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

alHardwareFan3RpmAlarm 1.3.6.1.4.1.3076.2.1.2.22.1.46
The alarm status for fan 3 RPM. This alarm will fired when fan 3 RPM is detected out of configured range.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

alHardwareFan3RpmCount 1.3.6.1.4.1.3076.2.1.2.22.1.47
The number of alarm events for fan 3 RPM.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

alHardwareFan3RpmTime 1.3.6.1.4.1.3076.2.1.2.22.1.48
The sysUptime at the time of the last change of alarm status for fan 3 RPM.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

alHardwarePs1Type 1.3.6.1.4.1.3076.2.1.2.22.1.49
The type of power supply for Power Supply slot 1.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), ac(2)  

alHardwarePs2Type 1.3.6.1.4.1.3076.2.1.2.22.1.50
The type of power supply for Power Supply slot 2.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), ac(2)  

alHardwareSlot1Card 1.3.6.1.4.1.3076.2.1.2.22.1.51
The type of card in slot 1.
Status: current Access: read-only
OBJECT-TYPE    
  ConcentratorCard  

alHardwareSlot2Card 1.3.6.1.4.1.3076.2.1.2.22.1.52
The type of card in slot 2.
Status: current Access: read-only
OBJECT-TYPE    
  ConcentratorCard  

alHardwareSlot3Card 1.3.6.1.4.1.3076.2.1.2.22.1.53
The type of card in slot 3.
Status: current Access: read-only
OBJECT-TYPE    
  ConcentratorCard  

alHardwareSlot4Card 1.3.6.1.4.1.3076.2.1.2.22.1.54
The type of card in slot 4.
Status: current Access: read-only
OBJECT-TYPE    
  ConcentratorCard  

alHardwareSlot1Operational 1.3.6.1.4.1.3076.2.1.2.22.1.55
The operational status of card in slot 1.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

alHardwareSlot2Operational 1.3.6.1.4.1.3076.2.1.2.22.1.56
The operational status of card in slot 2.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

alHardwareSlot3Operational 1.3.6.1.4.1.3076.2.1.2.22.1.57
The operational status of card in slot 3.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

alHardwareSlot4Operational 1.3.6.1.4.1.3076.2.1.2.22.1.58
The operational status of card in slot 4.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

alHardwareRamSize 1.3.6.1.4.1.3076.2.1.2.22.1.59
The amount of memory, in MB on the concentrator.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

alHardwareChassis 1.3.6.1.4.1.3076.2.1.2.22.1.60
The type of VPN Concentrator this is.
Status: current Access: read-only
OBJECT-TYPE    
  ConcentratorType  

alHardwareCpuVoltageNominal 1.3.6.1.4.1.3076.2.1.2.22.1.61
The nominal CPU voltage in centivolts for the concentrator.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

alHardwareClientEthPrivSwitch 1.3.6.1.4.1.3076.2.1.2.22.1.62
Whether or not the 3002 Hardware Client has an Ethernet Switch for the private interface.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

alHardwareSerialNumber 1.3.6.1.4.1.3076.2.1.2.22.1.63
Unit serial number.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

altigaHardwareStatsMibConformance 1.3.6.1.4.1.3076.1.1.27.2.1
OBJECT IDENTIFIER    

altigaHardwareStatsMibCompliances 1.3.6.1.4.1.3076.1.1.27.2.1.1
OBJECT IDENTIFIER    

altigaHardwareStatsMibCompliance 1.3.6.1.4.1.3076.1.1.27.2.1.1.1
The compliance statement for agents which implement the Altiga Hardware Statistics MIB.
Status: current Access: read-only
MODULE-COMPLIANCE    

altigaHardwareStatsGroup 1.3.6.1.4.1.3076.2.1.1.1.22.2
The objects for Hardware statistics.
Status: current Access: read-only
OBJECT-GROUP