ALVARION-DOT11-WLAN-TST-MIB

File: ALVARION-DOT11-WLAN-TST-MIB.mib (42370 bytes)

Imported modules

RFC1155-SMI RFC1212-MIB

Imported symbols

enterprises Counter32 OBJECT-TYPE

Defined Types

MacAddress  
OCTET STRING Size(6)    

DisplayString  
OCTET STRING    

BrzLighteNewVvaEntry  
SEQUENCE    
  brzLightePcdacTableIdx INTEGER

BrzLightePcdacEntry  
SEQUENCE    
  brzLightePcdacTableIdx INTEGER
  brzLightePcdacTableData INTEGER

BrzLightePcdacChannelsEntry  
SEQUENCE    
  brzLightePcdacChannelsTableIdx INTEGER
  brzLightePcdacChannelsTableData INTEGER

BrzLighteRxRssiEntry  
SEQUENCE    
  brzLighteRxRssiTableIdx INTEGER
  brzLighteRxRssiTableData INTEGER

BrzLighteTxPowerEntry  
SEQUENCE    
  brzLighteTxPowerTableIdx INTEGER
  brzLighteTxPowerTablePcdac INTEGER

BrzLighteAtherosRegEntry  
SEQUENCE    
  brzLighteAtehrosRegValue INTEGER
  brzLighteAtherosRegOffsetMask INTEGER

Defined Values

alvarion 1.3.6.1.4.1.12394
OBJECT IDENTIFIER    

alvarionPrvRev 1.3.6.1.4.1.12394.3
OBJECT IDENTIFIER    

brzLighteningMib 1.3.6.1.4.1.12394.3.1
OBJECT IDENTIFIER    

brzLighteningTest 1.3.6.1.4.1.12394.3.2
OBJECT IDENTIFIER    

brzLighteGenParams 1.3.6.1.4.1.12394.3.2.1
OBJECT IDENTIFIER    

brzLighteUnitName 1.3.6.1.4.1.12394.3.2.1.1
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

brzLighteUnitType 1.3.6.1.4.1.12394.3.2.1.2
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

brzLighteUnitBand 1.3.6.1.4.1.12394.3.2.1.3
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

brzLighteUnitHwVer 1.3.6.1.4.1.12394.3.2.1.4
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

brzLighteUnitSwVer 1.3.6.1.4.1.12394.3.2.1.5
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

brzLighteUnitShadowVer 1.3.6.1.4.1.12394.3.2.1.6
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

brzLighteUnitFlashType 1.3.6.1.4.1.12394.3.2.1.7
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

brzLighteUnitFlashSize 1.3.6.1.4.1.12394.3.2.1.8
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

brzLighteUnitStatus 1.3.6.1.4.1.12394.3.2.1.10
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER scanning(0), syncWaitForAdd(1), authenticating(2), authenticated(3), associated(4), unknown(5)  

brzLighteUnitAssocStatus 1.3.6.1.4.1.12394.3.2.1.11
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

brzLighteUnitBssId 1.3.6.1.4.1.12394.3.2.1.12
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  MacAddress  

brzLighteUnitMacAddress 1.3.6.1.4.1.12394.3.2.1.13
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

brzLighteLockFlashUnitMacAddress 1.3.6.1.4.1.12394.3.2.1.14
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER flashMacAddLock(1), flashMacAddUnLock(2)  

brzLighteUnitHWReset 1.3.6.1.4.1.12394.3.2.1.15
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER resetHW(1), cancel(2)  

brzLighteTxRxSettings 1.3.6.1.4.1.12394.3.2.2
OBJECT IDENTIFIER    

brzLighteSetTransmitMode 1.3.6.1.4.1.12394.3.2.2.1
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER contTx100Data(1), txCW(3), contTx99Data(4)  

brzLighteTxFrequencyCenter 1.3.6.1.4.1.12394.3.2.2.2
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLighteRxFrequencyCenter 1.3.6.1.4.1.12394.3.2.2.3
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLighteTransmitParams 1.3.6.1.4.1.12394.3.2.2.4
OBJECT IDENTIFIER    

brzLighteTransmitPowerLevel 1.3.6.1.4.1.12394.3.2.2.4.1
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLighteBitRate 1.3.6.1.4.1.12394.3.2.2.4.2
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER mbps6(6), mbps9(9), mbps12(12), mbps18(18), mbps24(24), mbps36(36), mbps48(48), mbps54(54)  

brzLighteTxVVAParams 1.3.6.1.4.1.12394.3.2.2.4.3
OBJECT IDENTIFIER    

brzLighteSetTxVVA 1.3.6.1.4.1.12394.3.2.2.4.3.1
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLighteVVATableStatus 1.3.6.1.4.1.12394.3.2.2.4.3.7
.
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER unBurned(0), burned(1)  

brzLightePoutAtTRSwitchRxMode 1.3.6.1.4.1.12394.3.2.2.4.3.8
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

brzLighteNewVvaParams 1.3.6.1.4.1.12394.3.2.2.4.3.9
OBJECT IDENTIFIER    

brzLighteSetOpenLoopState 1.3.6.1.4.1.12394.3.2.2.4.3.9.1
Set The unit to min pcdac power , vva 0 , open loop state -> for rev C only.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER cancel(0), setOpenLoop(1)  

brzLighteMaxPowerOpenLoop 1.3.6.1.4.1.12394.3.2.2.4.3.9.2
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

brzLighteNewVvaTable 1.3.6.1.4.1.12394.3.2.2.4.3.9.7
A table of up to 63 indexes.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    BrzLighteNewVvaEntry

brzLighteNewVvaEntry 1.3.6.1.4.1.12394.3.2.2.4.3.9.7.1
A table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  BrzLighteNewVvaEntry  

brzLighteNewVvaTableIndex 1.3.6.1.4.1.12394.3.2.2.4.3.9.7.1.1
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLighteNewVvaTableData 1.3.6.1.4.1.12394.3.2.2.4.3.9.7.1.2
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLighteTxNewVVATableRequest 1.3.6.1.4.1.12394.3.2.2.4.3.9.8
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER burn(0), load(1), cancel(2)  

brzLighteMaxPowerAtMaxRate 1.3.6.1.4.1.12394.3.2.2.4.3.9.9
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

brzLighteNewVVaTableStatus 1.3.6.1.4.1.12394.3.2.2.4.3.9.10
0 = NOT Calibrated - use Hard Coded Table accordig to Hw Revision , 1 = VVa Table calibrated for 5.4 GHz Units.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER vvaNotCalibrated(0), vvaCalibrated(1)  

brzLighteFixVVaAttenuation54GHz 1.3.6.1.4.1.12394.3.2.2.4.3.9.11
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

brzLighteSetNewVVaTableToLinear 1.3.6.1.4.1.12394.3.2.2.4.3.9.12
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER cancel(0), setLinear(1)  

brzLightePCDAC 1.3.6.1.4.1.12394.3.2.2.4.4
OBJECT IDENTIFIER    

brzLightePcdacTable 1.3.6.1.4.1.12394.3.2.2.4.4.1
A table of up to 63 indexes.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    BrzLightePcdacEntry

brzLightePcdacEntry 1.3.6.1.4.1.12394.3.2.2.4.4.1.1
A table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  BrzLightePcdacEntry  

brzLightePcdacTableIdx 1.3.6.1.4.1.12394.3.2.2.4.4.1.1.1
A table Index.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER pcdacMin(0), pcdacMax(1), pcdac0pcnt(2), pcdac5pcnt(3), pcdac10pcnt(4), pcdac20pcnt(5), pcdac30pcnt(6), pcdac50pcnt(7), pcdac70pcnt(8), pcdac85pcnt(9), pcdac90pcnt(10), pcdac95pcnt(11), pcdac100pcnt(12)  

brzLightePcdacTableData 1.3.6.1.4.1.12394.3.2.2.4.4.1.1.2
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLightePcdacTableCurrentChannel 1.3.6.1.4.1.12394.3.2.2.4.4.2
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLightePcdacTableRequest 1.3.6.1.4.1.12394.3.2.2.4.4.3
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER writepcdacChannels(0), writepcdacValues(1), cancel(2)  

brzLightePcdacBurnToFlash 1.3.6.1.4.1.12394.3.2.2.4.4.4
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER cancel(0), burntoflash(1)  

brzLightePcdacChannelsTable 1.3.6.1.4.1.12394.3.2.2.4.4.5
A table of up to 10 indexes.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    BrzLightePcdacChannelsEntry

brzLightePcdacChannelsEntry 1.3.6.1.4.1.12394.3.2.2.4.4.5.1
A table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  BrzLightePcdacChannelsEntry  

brzLightePcdacChannelsTableIdx 1.3.6.1.4.1.12394.3.2.2.4.4.5.1.1
A table Index.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER channel0(0), channel1(1), channel2(2), channel3(3), channel4(4), channel5(5), channel6(6), channel7(7), channel8(8), channel9(9)  

brzLightePcdacChannelsTableData 1.3.6.1.4.1.12394.3.2.2.4.4.5.1.2
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLighteTransmit 1.3.6.1.4.1.12394.3.2.2.4.5
OBJECT IDENTIFIER    

brzLighteSetTransmitOn 1.3.6.1.4.1.12394.3.2.2.4.5.1
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER startTx(1), stopTx(2)  

brzLighteforcePowerTx 1.3.6.1.4.1.12394.3.2.2.4.6
Enter the power multipled by 2.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLighteRereadProm 1.3.6.1.4.1.12394.3.2.2.4.7
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLighteTypeOfTxPattern 1.3.6.1.4.1.12394.3.2.2.4.8
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER fixedPattern(0), randomPattern(1)  

brzLighteTxFixedPattern 1.3.6.1.4.1.12394.3.2.2.4.9
Enter Exactly 8 Hex digits.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

brzLighteTurboMode 1.3.6.1.4.1.12394.3.2.2.4.10
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(0), turbo(1), half(2), quarter(3)  

brzLightenewTxGainOffset 1.3.6.1.4.1.12394.3.2.2.4.11
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLighteGainStep 1.3.6.1.4.1.12394.3.2.2.4.12
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLighteChannelMode 1.3.6.1.4.1.12394.3.2.2.4.13
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER channel57(0), channel24(1)  

brzLighteRawPowerDataRevisionC 1.3.6.1.4.1.12394.3.2.2.4.14
OBJECT IDENTIFIER    

brzLightePwr1Xg1 1.3.6.1.4.1.12394.3.2.2.4.14.1
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLightePwr2Xg1 1.3.6.1.4.1.12394.3.2.2.4.14.2
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLightePwr3Xg1 1.3.6.1.4.1.12394.3.2.2.4.14.3
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLightePwr4Xg1 1.3.6.1.4.1.12394.3.2.2.4.14.4
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLightePcd2Delta 1.3.6.1.4.1.12394.3.2.2.4.14.5
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLightePcd3Delta 1.3.6.1.4.1.12394.3.2.2.4.14.6
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLightePcd4Delta 1.3.6.1.4.1.12394.3.2.2.4.14.7
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLightePwr1xg2 1.3.6.1.4.1.12394.3.2.2.4.14.8
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLightePwr2xg2 1.3.6.1.4.1.12394.3.2.2.4.14.9
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLightePwr3xg2 1.3.6.1.4.1.12394.3.2.2.4.14.10
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLightePcd1 1.3.6.1.4.1.12394.3.2.2.4.14.11
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLighteTxGainForNormalMode 1.3.6.1.4.1.12394.3.2.2.4.15
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLighteRecieveParams 1.3.6.1.4.1.12394.3.2.2.5
OBJECT IDENTIFIER    

brzLighteRxVVA 1.3.6.1.4.1.12394.3.2.2.5.2
OBJECT IDENTIFIER    

brzLighteSetRxVVA 1.3.6.1.4.1.12394.3.2.2.5.2.1
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLighteTRSwitchControl 1.3.6.1.4.1.12394.3.2.2.6
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), rxandTxattenuated(2), txattenuatedstate(3), rxattenuatedstate(4)  

brzLighteTRSwitchOption 1.3.6.1.4.1.12394.3.2.2.7
Enable/Disable the TR/Switch algorithm running in normal mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

brzLightePcktLen 1.3.6.1.4.1.12394.3.2.2.8
Packet length for OFDM 99% - Body length
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..4056  

brzLighteTests 1.3.6.1.4.1.12394.3.2.3
OBJECT IDENTIFIER    

brzLighteBerPerTest 1.3.6.1.4.1.12394.3.2.3.1
OBJECT IDENTIFIER    

brzLighteBerPerParams 1.3.6.1.4.1.12394.3.2.3.1.1
OBJECT IDENTIFIER    

brzLighteBerPerParamsLength 1.3.6.1.4.1.12394.3.2.3.1.1.1
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLighteBerPerParamsInterval 1.3.6.1.4.1.12394.3.2.3.1.1.2
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLighteBerPerParamsRate 1.3.6.1.4.1.12394.3.2.3.1.1.3
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER mbps6(6), mbps9(9), mbps12(12), mbps18(18), mbps24(24), mbps36(36), mbps48(48), mbps54(54)  

brzLighteBerPerParamsPackets 1.3.6.1.4.1.12394.3.2.3.1.1.4
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLighteResetBerPerCounters 1.3.6.1.4.1.12394.3.2.3.1.2
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER cancel(0), reset(1)  

brzLighteRunBerPerTest 1.3.6.1.4.1.12394.3.2.3.1.3
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER runTxbertest(0), runRxbertest(1), stoptest(2)  

brzLighteBerPerTestResults 1.3.6.1.4.1.12394.3.2.3.1.4
OBJECT IDENTIFIER    

brzLighteErrors 1.3.6.1.4.1.12394.3.2.3.1.4.1
Applicable to SU and AU. Read-only. The number of frames received from the wireless media with errors (CRC errors).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

brzLighteGoodPacketsRecieved 1.3.6.1.4.1.12394.3.2.3.1.4.3
Applicable to SU and AU. Read only. The total number of frames that were received from the wireless media. The count includes data and control and management frames, including beacons received from the AU. The count does not include frames that were discarded internally, bad frames and duplicate frames.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

brzLighteRssiTest 1.3.6.1.4.1.12394.3.2.3.2
OBJECT IDENTIFIER    

brzLighteAvgRssiRecieved 1.3.6.1.4.1.12394.3.2.3.2.1
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLighteInRangeRecievedPackets 1.3.6.1.4.1.12394.3.2.3.2.2
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLighteOutOfRangeRecievedPackets 1.3.6.1.4.1.12394.3.2.3.2.3
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLighteRxRssiTable 1.3.6.1.4.1.12394.3.2.3.2.4
A table of up to 63 indexes.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    BrzLighteRxRssiEntry

brzLighteRxRssiEntry 1.3.6.1.4.1.12394.3.2.3.2.4.1
A table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  BrzLighteRxRssiEntry  

brzLighteRxRssiTableIdx 1.3.6.1.4.1.12394.3.2.3.2.4.1.1
A table Index.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

brzLighteRxRssiTableData 1.3.6.1.4.1.12394.3.2.3.2.4.1.2
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

brzLighteBistTest 1.3.6.1.4.1.12394.3.2.3.3
OBJECT IDENTIFIER    

brzLighteMemoryTestResult 1.3.6.1.4.1.12394.3.2.3.3.1
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER pass(0), fail(1)  

brzLighteEthernetMacRegTestResult 1.3.6.1.4.1.12394.3.2.3.3.2
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER pass(0), fail(1)  

brzLighteEthernetPhyRegTestResult 1.3.6.1.4.1.12394.3.2.3.3.3
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER pass(0), fail(1)  

brzLighteEthernetIntrptTestResult 1.3.6.1.4.1.12394.3.2.3.3.4
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER pass(0), fail(1)  

brzLightLedsTest 1.3.6.1.4.1.12394.3.2.3.4
OBJECT IDENTIFIER    

brzLighteTurnLedsOn 1.3.6.1.4.1.12394.3.2.3.4.1
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER turnLedsOn(1), turnLedsOff(2)  

brzLightDebugParams 1.3.6.1.4.1.12394.3.2.5
OBJECT IDENTIFIER    

brzLighteSwitchSettintTime 1.3.6.1.4.1.12394.3.2.5.1
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLighteTxEndToXlnaOn 1.3.6.1.4.1.12394.3.2.5.2
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLighteTxEndToXpaOff 1.3.6.1.4.1.12394.3.2.5.3
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLighteTxFrameToXpaOn 1.3.6.1.4.1.12394.3.2.5.4
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLighteBeaconsRate 1.3.6.1.4.1.12394.3.2.5.5
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER stopBeacons(1), cancel(2)  

brzLighteObSetting 1.3.6.1.4.1.12394.3.2.5.6
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLighteDbSetting 1.3.6.1.4.1.12394.3.2.5.7
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLighteXpdGain 1.3.6.1.4.1.12394.3.2.5.8
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER val0(0), val6(6), val12(12), val18(18)  

brzLighteToggleExternalPower 1.3.6.1.4.1.12394.3.2.5.9
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLightePowerOverride 1.3.6.1.4.1.12394.3.2.5.10
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLighteAntennaSwitch 1.3.6.1.4.1.12394.3.2.5.11
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER switch(1), cancel(2)  

brzLighteRfGainBoost 1.3.6.1.4.1.12394.3.2.5.12
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER val0(0), val5(5), val10(10)  

brzLighteConfigSet 1.3.6.1.4.1.12394.3.2.5.13
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER regConfig(1), cancel(2)  

brzLighteTxPowerTable 1.3.6.1.4.1.12394.3.2.5.14
A table of up to 63 indexes.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    BrzLighteTxPowerEntry

brzLighteTxPowerEntry 1.3.6.1.4.1.12394.3.2.5.14.1
A table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  BrzLighteTxPowerEntry  

brzLighteTxPowerTableIdx 1.3.6.1.4.1.12394.3.2.5.14.1.1
A table Index.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

brzLighteTxPowerTablePcdac 1.3.6.1.4.1.12394.3.2.5.14.1.2
A table Index.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

brzLighteFtpStatus 1.3.6.1.4.1.12394.3.2.5.15
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ftpActive(1), ftpSuccess(2), ftpFail(3)  

brzLightAuAvarageSNR 1.3.6.1.4.1.12394.3.2.5.16
OBJECT IDENTIFIER    

brzLighteAuAvgSNRSupport 1.3.6.1.4.1.12394.3.2.5.16.1
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

brzLighteShowAuAvgSNR 1.3.6.1.4.1.12394.3.2.5.16.2
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzaccVLRtsCtsFailed 1.3.6.1.4.1.12394.3.2.5.17
.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

brzLighteHeatControl 1.3.6.1.4.1.12394.3.2.5.18
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normalheatoperation(0), macrocheateron(1)  

brzLightePaSleepControl 1.3.6.1.4.1.12394.3.2.5.19
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER paSleepOfF(0), paSleepOn(1)  

brzLighteFilterControl 1.3.6.1.4.1.12394.3.2.5.20
When FIL_SEL='0' Japanese lower band 4950 MHz is Selected When FIL_SEL='1' Japanese upper band 5060 MHz is Selected.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER lowband(0), upperBand(1)  

brzLighteTxframetotxdstart 1.3.6.1.4.1.12394.3.2.5.21
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLighteTxframetoxpaaon 1.3.6.1.4.1.12394.3.2.5.22
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLighteAteMode 1.3.6.1.4.1.12394.3.2.7
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normalMode(0), ateModeTx(1), ateModeRx(2)  

brzLighteWCU 1.3.6.1.4.1.12394.3.2.9
OBJECT IDENTIFIER    

brzLighteChallengeText 1.3.6.1.4.1.12394.3.2.9.1
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

brzLighteCpldVersion 1.3.6.1.4.1.12394.3.2.9.2
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

brzLighteAuType 1.3.6.1.4.1.12394.3.2.9.3
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER auNI(1), auBS(2), suOnly(3)  

brzLighteHwMaxRate 1.3.6.1.4.1.12394.3.2.9.4
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER rate6Mbps(1), rate24Mbps(2), rate14Mbps(3), rate28Mbps(4), rate54Mbps(5), rateUnLimitedMbps(6), rate3Mbps(7), rateSUIMbps(9)  

brzLighteSysConfiguration 1.3.6.1.4.1.12394.3.2.9.5
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER pToMultiPoint(1), pToPoint(2)  

brzaccVLUnitHwOutputPower 1.3.6.1.4.1.12394.3.2.9.6
Applicable to AU and SU. The output power to the antenna port supported by the unit
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

brzLighteChannelBandwidth 1.3.6.1.4.1.12394.3.2.9.7
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER channelBW5Mhz(1), channelBW10Mhz(2), channelBW20Mhz(3)  

brzLighteDeleteShadowVersion 1.3.6.1.4.1.12394.3.2.9.8
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER deleteShadow(1), cancel(2)  

brzLighteBridgeMode 1.3.6.1.4.1.12394.3.2.9.9
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER modeBD(1), mode1D(2), mode4D(3)  

brzLighteSecurityPermissions 1.3.6.1.4.1.12394.3.2.9.10
OBJECT IDENTIFIER    

brzLighteSecurityPermission 1.3.6.1.4.1.12394.3.2.9.10.1
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER forbidden(1), permitted(2)  

brzLighteDataEncryption 1.3.6.1.4.1.12394.3.2.9.10.2
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER forbidden(1), permitted(2)  

brzLighteEncryptionByAes 1.3.6.1.4.1.12394.3.2.9.10.3
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER forbidden(1), permitted(2)  

authenticationBySharedKeyAlgorithm 1.3.6.1.4.1.12394.3.2.9.10.4
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER forbidden(1), permitted(2)  

brzLighteUnitConfigurationMode 1.3.6.1.4.1.12394.3.2.9.11
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER aubs(1), ausa(2), su61d(3), su6bd(4), su24bd(5), bub14(6), bub28(7), rbb14(8), rbb28(9), subd(10), su54bd(11), su31d(12), su34d(13), ausbs(14), aussa(15), aubs4900(16), ausa4900(17), subd4900(18), bub100(19), rbb100(20), sui(21), auez(22), setdefaults(100)  

brzLighteHwUnitType 1.3.6.1.4.1.12394.3.2.9.12
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER au(1), su(2), ateau(3), atesu(4)  

brzLighteSetConfigurationMode 1.3.6.1.4.1.12394.3.2.9.13
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER aubs(1), ausa(2), su61d(3), su6bd(4), su24bd(5), bub14(6), bub28(7), rbb14(8), rbb28(9), subd(10), su54bd(11), su31d(12), su34d(13), ausbs(14), aussa(15), aubs4900(16), ausa4900(17), subd4900(18), bub100(19), rbb100(20), sui(21), auez(22), setdefaults(100)  

brzLighteCountryCode 1.3.6.1.4.1.12394.3.2.9.14
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLighteAntennaGain 1.3.6.1.4.1.12394.3.2.9.15
-1 stands for: do NOT transmit, -2 stands for: don't care.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

brzLighteOemParams 1.3.6.1.4.1.12394.3.2.9.16
OBJECT IDENTIFIER    

brzLighteFixOemType 1.3.6.1.4.1.12394.3.2.9.16.1
Get/Set OEM Type of Unit. 1: Alvarion, 4: Nera, 6: Empty OEM Strings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(32)  

brzLighteOemProjectNameString 1.3.6.1.4.1.12394.3.2.9.16.2
Get/Set OEM Product Line of Unit. The setting is only possible if the oem string is empty.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(32)  

brzLighteOemManufactureNameString 1.3.6.1.4.1.12394.3.2.9.16.3
Get/Set OEM Vendor Name for Unit. The setting is only possible if the oem string is empty.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(32)  

brzLighteSetMibEnterprise 1.3.6.1.4.1.12394.3.2.9.16.4
enterprise710 - breezecom, enterprise8295 - bwa. will come into effect only after next reset. To use this, the unit must be in technician mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enterprise710(710), enterprise8295(8295)  

brzLighteAtherosRegTable 1.3.6.1.4.1.12394.3.2.11
Applicable to all units. Atheros registers Table
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    BrzLighteAtherosRegEntry

brzLighteAtherosRegEntry 1.3.6.1.4.1.12394.3.2.11.1
Applicable to all units. AN entry in the Atheros register table
Status: current Access: not-accessible
OBJECT-TYPE    
  BrzLighteAtherosRegEntry  

brzLighteAtehrosRegValue 1.3.6.1.4.1.12394.3.2.11.1.1
Tok_String
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLighteAtherosRegOffsetMask 1.3.6.1.4.1.12394.3.2.11.1.2
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

brzLighteAUSSubscribersNo 1.3.6.1.4.1.12394.3.2.9.17
Number of Subscribers that can be associated to AUS
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  


brzLighteBNB10MHzSupport 1.3.6.1.4.1.12394.3.2.9.20
Applicable to BNB only
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER nonSupported(0), supported(1)  

brzLighteModemUtilisation 1.3.6.1.4.1.12394.3.2.12
Modem Utilization value
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

brzLighteANI 1.3.6.1.4.1.12394.3.2.13
OBJECT IDENTIFIER    

brzLighteNoiseImmunityStateControl 1.3.6.1.4.1.12394.3.2.13.1
Noise Immunity State Control
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER manual(0), automatic(1)  

brzLighteNoiseImmunityLevel 1.3.6.1.4.1.12394.3.2.13.2
Noise Immunity Level Allowed range is 0 to 4
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLighteSpurImunityLevel 1.3.6.1.4.1.12394.3.2.13.3
Spur Imunity Level Allowed range is 0 to 7
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLighteOFDMWeakSignal 1.3.6.1.4.1.12394.3.2.13.4
OFDM Weak Signal Allowed range is 0 to 1
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

brzLightePulseDetectionSensitivity 1.3.6.1.4.1.12394.3.2.13.5
Pulse Detection Sensitivity
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER low(0), high(1)  

brzLighteANIState 1.3.6.1.4.1.12394.3.2.14
OBJECT IDENTIFIER    

brzLightenoiseImmunityLevel 1.3.6.1.4.1.12394.3.2.14.1
noiseImmunityLevel
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

brzLightespurImmunity 1.3.6.1.4.1.12394.3.2.14.2
spurImmunityLevel
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

brzLighteofdmWeakSigDetectionOff 1.3.6.1.4.1.12394.3.2.14.3
ofdmWeakSigDetectionOff
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

brzLightecckWeakSigThresholdHigh 1.3.6.1.4.1.12394.3.2.14.4
cckWeakSigThresholdHigh
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

brzLightefirstepLevel 1.3.6.1.4.1.12394.3.2.14.5
firstepLevel
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

brzLightespurImmunityBias 1.3.6.1.4.1.12394.3.2.14.6
spurImmunityBias
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

brzLightephyErrStatsDisabled 1.3.6.1.4.1.12394.3.2.14.7
phyErrStatsDisabled
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

brzLighteVLAteSetTestResults 1.3.6.1.4.1.12394.3.2.1.16
Set the Ate Test Results
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(0), pass(1), fail(2)  

brzLighteVLSetSerialNumber 1.3.6.1.4.1.12394.3.2.1.17
Set the Serial Number
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..35)