ANS-EQUIPMENT-MIB

File: ANS-EQUIPMENT-MIB.mib (30024 bytes)

Imported modules

SNMPv2-SMI RFC1213-MIB ANS-COMMON-MIB

Imported symbols

OBJECT-TYPE DisplayString RowPointer
RowStatus mlpmpR115

Defined Types

AnsSubrackType  
INTEGER badvalue(-1), concentrator(7), wbas(9)    

ProtectedBoardType  
INTEGER wbas-rn(1)    

AnsSystemNodeEntry  
SEQUENCE    
  ansSystemNodeIndex INTEGER
  ansSystemNodeName DisplayString
  ansSystemNodeOrigin INTEGER
  ansSystemNodeLocation DisplayString
  ansSystemNodeClockSource INTEGER
  ansSystemNodeRowStatus RowStatus

AnsSubrackEntry  
SEQUENCE    
  ansSubrackSystemNodeIndex INTEGER
  ansSubrackIndex INTEGER
  ansSubrackName DisplayString
  ansSubrackHwId DisplayString Size(46)
  ansSubrackLocation DisplayString
  ansSubrackType AnsSubrackType
  ansSubrackProtectionState INTEGER
  ansSubrackProtectionScheme DisplayString
  ansSubrackNoOfSlots INTEGER
  ansSubrackAlarmStatus INTEGER
  ansSubrackRowStatus RowStatus

AnsSlotEntry  
SEQUENCE    
  ansSlotSystemNodeIndex INTEGER
  ansSlotSubrackIndex INTEGER
  ansSlotPosition INTEGER
  ansSlotConfiguredBoardId DisplayString Size(0..46)
  ansSlotInsertedBoardId DisplayString Size(0..46)
  ansSlotManagementStatus INTEGER
  ansSlotFallback INTEGER
  ansSlotAlarmStatus INTEGER

AnsBoardEntry  
SEQUENCE    
  ansBoardSystemNodeIndex INTEGER
  ansBoardSubrackIndex INTEGER
  ansBoardPosition INTEGER
  ansBoardType DisplayString Size(0..20)
  ansBoardHwId DisplayString Size(46)
  ansBoardSwIdActive DisplayString Size(29)
  ansBoardSwIdPassive DisplayString Size(29)
  ansBoardOperStatus INTEGER
  ansBoardAdminStatus INTEGER
  ansBoardRestart INTEGER
  ansBoardLedStatus INTEGER
  ansBoardStandbyStatus INTEGER
  ansBoardAlarmStatus INTEGER
  ansBoardUsageState INTEGER
  ansBoardSyncMode INTEGER

AnsPhysicalPointEntry  
SEQUENCE    
  ansPhysicalPointSystemNodeIndex INTEGER
  ansPhysicalPointSubrackIndex INTEGER
  ansPhysicalPointPosition INTEGER
  ansPhysicalPointIndex INTEGER
  ansDsPhysicalPointSystemNodeIndex INTEGER
  ansDsPhysicalPointSubrackIndex INTEGER
  ansDsPhysicalPointPosition INTEGER
  ansDsPhysicalPointIndex INTEGER
  ansPhysicalPointType INTEGER
  ansPhysicalPointCategory INTEGER
  ansPhysicalPointOperStatus INTEGER
  ansPhysicalPointAdminStatus INTEGER
  ansPhysicalPointUsageState INTEGER

NetClockSourceEntry  
SEQUENCE    
  netClockSourceSystemNodeIndex INTEGER
  netClockSourceSubrack INTEGER
  netClockSourceSlot INTEGER
  netClockSourcePort INTEGER
  netClockSourceStatus INTEGER
  netClockSourcePriorityList DisplayString
  netClockSourceRevertiveMode INTEGER
  netClockSourceTimeToRestore INTEGER
  netClockSourceRowStatus RowStatus

Defined Values

equipment 1.3.6.1.4.1.193.96.115.3
OBJECT IDENTIFIER    

systemNode 1.3.6.1.4.1.193.96.115.3.1
OBJECT IDENTIFIER    

subrack 1.3.6.1.4.1.193.96.115.3.2
OBJECT IDENTIFIER    

slot 1.3.6.1.4.1.193.96.115.3.3
OBJECT IDENTIFIER    

board 1.3.6.1.4.1.193.96.115.3.4
OBJECT IDENTIFIER    

physicalPoint 1.3.6.1.4.1.193.96.115.3.5
OBJECT IDENTIFIER    

netClockSource 1.3.6.1.4.1.193.96.115.3.6
OBJECT IDENTIFIER    

ansSystemNodeTable 1.3.6.1.4.1.193.96.115.3.1.3
Lists of all system nodes in ANx.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AnsSystemNodeEntry

ansSystemNodeEntry 1.3.6.1.4.1.193.96.115.3.1.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AnsSystemNodeEntry  

ansSystemNodeIndex 1.3.6.1.4.1.193.96.115.3.1.3.1.1
A unique value for the system node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ansSystemNodeName 1.3.6.1.4.1.193.96.115.3.1.3.1.2
An assigned name for the system node.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

ansSystemNodeOrigin 1.3.6.1.4.1.193.96.115.3.1.3.1.3
'native' indicates that the system node is managed by this agent.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER native(1)  

ansSystemNodeLocation 1.3.6.1.4.1.193.96.115.3.1.3.1.4
An indication where the system node is located. This could be indicated as a row/cabinet/shelf, a place in a building, and/or a street address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

ansSystemNodeClockSource 1.3.6.1.4.1.193.96.115.3.1.3.1.5
'net-clock-source' indicates that in the system node is defined the Net Master.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER undefined(1), net-clock-source(2)  

ansSystemNodeRowStatus 1.3.6.1.4.1.193.96.115.3.1.3.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  RowStatus  

ansSubrackTable 1.3.6.1.4.1.193.96.115.3.2.2
Lists of all subracks in ANx.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AnsSubrackEntry

ansSubrackEntry 1.3.6.1.4.1.193.96.115.3.2.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AnsSubrackEntry  

ansSubrackSystemNodeIndex 1.3.6.1.4.1.193.96.115.3.2.2.1.1
A reference to the associated system node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ansSubrackIndex 1.3.6.1.4.1.193.96.115.3.2.2.1.2
A unique value for this subrack.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ansSubrackName 1.3.6.1.4.1.193.96.115.3.2.2.1.3
An assigned name for the subrack.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

ansSubrackHwId 1.3.6.1.4.1.193.96.115.3.2.2.1.4
Hardware identity string stored in PROM in the subrack. The ASCII string is encoded as follows: ansSubrackHwId[0-15] : Procuct number (e.g. ROJ 212 16/1), [16 ASCII characters] ansSubrackHwId[16-22] : Version (e.g. P1C/3), [7 ASCII characters] ansSubrackHwId[23-34] : Serial number (e.g. A270000141) [12 ASCII characters] ansSubrackHwId[35-40] : Vendor (e.g. ETX) [6 ASCII characters] ansSubrackHwId[31-44] : Spare (not used) [4 ASCII characters] ansSubrackHwId[45] : CR (Carrige Return) [1 ASCII character]
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(46)  

ansSubrackLocation 1.3.6.1.4.1.193.96.115.3.2.2.1.5
An indication where the subrack is located. This could be indicated as a row/cabinet/shelf, a place in a building, and/or a street address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

ansSubrackType 1.3.6.1.4.1.193.96.115.3.2.2.1.6
Identifies subrack type.
Status: mandatory Access: read-write
OBJECT-TYPE    
  AnsSubrackType  

ansSubrackProtectionState 1.3.6.1.4.1.193.96.115.3.2.2.1.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER not-protected(1), protected(2)  

ansSubrackProtectionScheme 1.3.6.1.4.1.193.96.115.3.2.2.1.8
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

ansSubrackNoOfSlots 1.3.6.1.4.1.193.96.115.3.2.2.1.9
The number of slots in the subrack.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ansSubrackAlarmStatus 1.3.6.1.4.1.193.96.115.3.2.2.1.10
Bitmap indicating the current alarm status of the subrack. The status codes are: 0: subrackNoDefect 2: subrackCommunicationLost 4: subrackFanFailure 8: subrackPowerFailure 16: Not used. 32: subrackMismatch 64: Not used. 128: Not used.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

ansSubrackRowStatus 1.3.6.1.4.1.193.96.115.3.2.2.1.11
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  RowStatus  

ansSlotTable 1.3.6.1.4.1.193.96.115.3.3.1
This table contains pre-configured and and actual board data for slots in ANx.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AnsSlotEntry

ansSlotEntry 1.3.6.1.4.1.193.96.115.3.3.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AnsSlotEntry  

ansSlotSystemNodeIndex 1.3.6.1.4.1.193.96.115.3.3.1.1.1
A reference to the associated system node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ansSlotSubrackIndex 1.3.6.1.4.1.193.96.115.3.3.1.1.2
A reference to the associated subrack
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ansSlotPosition 1.3.6.1.4.1.193.96.115.3.3.1.1.3
The value of this object identifies the slot within the subrack.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ansSlotConfiguredBoardId 1.3.6.1.4.1.193.96.115.3.3.1.1.4
Hardware identity string for the board configured for this slot. The string is encoded in the same way as ansSlotInsertedBoardId.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..46)  

ansSlotInsertedBoardId 1.3.6.1.4.1.193.96.115.3.3.1.1.5
This variable contains the identification string of the board inserted in this slot. The ASCII string is encoded as follows: ansSlotInsertedBoardId[0-15] : Procuct number (e.g. ROJ 212 16/1), [16 ASCII characters] ansSlotInsertedBoardId[16-22] : Version (e.g. P1C/3), [7 ASCII characters] ansSlotInsertedBoardId[23-34] : Serial number (e.g. A270000141) [12 ASCII characters] ansSlotInsertedBoardId[35-40] : Vendor (e.g. ETX) [6 ASCII characters] ansSlotInsertedBoardId[31-44] : Spare (not used) [4 ASCII characters] ansSlotInsertedBoardId[45] : CR (Carrige Return) [1 ASCII character]
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..46)  

ansSlotManagementStatus 1.3.6.1.4.1.193.96.115.3.3.1.1.6
This attribute shows the behaviour of a slot. The following values are possible: managed The slot is of management interest. Inserted boards will be detected and events/alarms will be generated for the slot. unmanaged The slot is currently not of management interest. No events or alarms will be generated for this slot. Possible boards inserted in the slot will not be detected and can not be taken into service. Default value of this object is 'managed'. unconfigEmpty Unconfigured empty slot. configEmpty Configured empty slot, that did not previously contain a matching board. configBoard Board inserted in the slot that matches the data configured for the slot.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER managed(1), unmanaged(2), unconfigEmpty(3), configEmpty(4), configBoard(5)  

ansSlotFallback 1.3.6.1.4.1.193.96.115.3.3.1.1.7
This variable indicates the fallback of the slot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER primary(1), secondary(2)  

ansSlotAlarmStatus 1.3.6.1.4.1.193.96.115.3.3.1.1.8
This variable indicates the current alarm status of the slot. Note that the first three states represent normal states. The different states are exclusive. The alarm codes are: 0: noDefectUnconfiguredEmptySlot (unconfigured empty slot) 1: noDefectConfiguredEmptySlot (configured empty slot, that did not previously contain a matching board) 2: noDefectMatchingBoardInserted (board inserted in the slot that matches the data configured for the slot) 4: boardRemoved (matching board has been removed from the slot) 8: unconfiguredBoardInserted (board inserted in an unconfigured slot) 16: boardMismatch (board inserted in a slot and the board does not match the data configured for the slot) 32: boardUnrecognized (unrecognized board inserted in the slot) 64: Not used. 128: Not used.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

ansBoardTable 1.3.6.1.4.1.193.96.115.3.4.2
This table contains all known boards in ANx.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AnsBoardEntry

ansBoardEntry 1.3.6.1.4.1.193.96.115.3.4.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AnsBoardEntry  

ansBoardSystemNodeIndex 1.3.6.1.4.1.193.96.115.3.4.2.1.1
A reference to the system node the board belongs to.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ansBoardSubrackIndex 1.3.6.1.4.1.193.96.115.3.4.2.1.2
A reference to the subrack the circuit board is inserted in.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ansBoardPosition 1.3.6.1.4.1.193.96.115.3.4.2.1.3
A reference to the slot within a subrack the circuit board is inserted in.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ansBoardType 1.3.6.1.4.1.193.96.115.3.4.2.1.4
Type of circuit board e.g. ET, RN, AT.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..20)  

ansBoardHwId 1.3.6.1.4.1.193.96.115.3.4.2.1.5
The identification string of the board The ASCII string is encoded as follows: ansBoardHwId[0-15] : Procuct number (e.g. ROJ 212 16/1), [16 ASCII characters] ansBoardHwId[16-22] : Version (e.g. P1C/3), [7 ASCII characters] ansBoardHwId[23-34] : Serial number (e.g. A270000141) [12 ASCII characters] ansBoardHwId[35-40] : Vendor (e.g. ETX) [6 ASCII characters] ansBoardHwId[31-44] : Spare (not used) [4 ASCII characters] ansBoardHwId[45] : CR (Carrige Return) [1 ASCII character]
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(46)  

ansBoardSwIdActive 1.3.6.1.4.1.193.96.115.3.4.2.1.6
Identifies the core software load module of the DP The ASCII string is encoded as follows: ansBoardSwIdCore[0-21]: Product Number [22 ASCII characters], ansBoardSwIdCore[22-28]: Version [7 ASCII characters]
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(29)  

ansBoardSwIdPassive 1.3.6.1.4.1.193.96.115.3.4.2.1.7
Identifies the application load module of the DP The ASCII string is encoded as follows: ansBoardSwIdApplication[0-21]: Product Number [22 ASCII characters], ansBoardSwIdApplication[22-28]: Version [7 ASCII characters]
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(29)  

ansBoardOperStatus 1.3.6.1.4.1.193.96.115.3.4.2.1.8
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ansBoardAdminStatus 1.3.6.1.4.1.193.96.115.3.4.2.1.9
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unlocked(1), locked(2)  

ansBoardRestart 1.3.6.1.4.1.193.96.115.3.4.2.1.10
Initiates a restart of the DP.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), restart(2)  

ansBoardLedStatus 1.3.6.1.4.1.193.96.115.3.4.2.1.11
Indicates the status of the board's red LED. (The green LED indicates that the board is powered and is asumed to always to be on) redOff : No failure has been detected. redOn : Failure has been detected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER redOff(1), redOn(2), none(3)  

ansBoardStandbyStatus 1.3.6.1.4.1.193.96.115.3.4.2.1.12
Indicates the standby status of the board.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER providing-service(1), cold-standby(2), null(3)  

ansBoardAlarmStatus 1.3.6.1.4.1.193.96.115.3.4.2.1.13
A bitmap that indicates the current alarm status of the circuit board. The alarm codes are: 0: boardNoDefect 1: boardFlashMemoryWarning 2: boardFlashMemoryError 4: boardRamWarning 8: boardRamError 16: boardEEPromWarning 32: boardEEPromError 64: boardMCNWarning 128: boardMCNError 256: Not Used. 512: boardRuntimeError 1024: boardStartError 2048: boardSoftwareError 4096: boardRuntimeWarning 8192: boardIncorrectSwVersion
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..16383  

ansBoardUsageState 1.3.6.1.4.1.193.96.115.3.4.2.1.14
Usage State
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER idle(1), active(2)  

ansBoardSyncMode 1.3.6.1.4.1.193.96.115.3.4.2.1.15
Clocking mode
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER master(1), slave(2), netMaster(3), notUsed(4)  

ansPhysicalPointTable 1.3.6.1.4.1.193.96.115.3.5.1
This table contains all known physical points in ANx.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AnsPhysicalPointEntry

ansPhysicalPointEntry 1.3.6.1.4.1.193.96.115.3.5.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AnsPhysicalPointEntry  

ansPhysicalPointSystemNodeIndex 1.3.6.1.4.1.193.96.115.3.5.1.1.1
A reference to the system node the physical point belongs to.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ansPhysicalPointSubrackIndex 1.3.6.1.4.1.193.96.115.3.5.1.1.2
A reference to the subrack the physical point belongs to.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ansPhysicalPointPosition 1.3.6.1.4.1.193.96.115.3.5.1.1.3
A reference to the board within a subrack the physical point belongs to.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ansPhysicalPointIndex 1.3.6.1.4.1.193.96.115.3.5.1.1.4
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ansDsPhysicalPointSystemNodeIndex 1.3.6.1.4.1.193.96.115.3.5.1.1.5
A reference to the downstream system node.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ansDsPhysicalPointSubrackIndex 1.3.6.1.4.1.193.96.115.3.5.1.1.6
A reference to the downstream subrack.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ansDsPhysicalPointPosition 1.3.6.1.4.1.193.96.115.3.5.1.1.7
A reference to the downstream board within a subrack.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ansDsPhysicalPointIndex 1.3.6.1.4.1.193.96.115.3.5.1.1.8
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ansPhysicalPointType 1.3.6.1.4.1.193.96.115.3.5.1.1.9
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER undefined(4), sdhUni(5), sdhUniTelia(6), sonetUni(7)  

ansPhysicalPointCategory 1.3.6.1.4.1.193.96.115.3.5.1.1.10
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER service(1), user(2), serviceUser(3), internal(4)  

ansPhysicalPointOperStatus 1.3.6.1.4.1.193.96.115.3.5.1.1.11
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ansPhysicalPointAdminStatus 1.3.6.1.4.1.193.96.115.3.5.1.1.12
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unlocked(1), locked(2)  

ansPhysicalPointUsageState 1.3.6.1.4.1.193.96.115.3.5.1.1.13
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER idle(1), active(2)  

netClockSourceTable 1.3.6.1.4.1.193.96.115.3.6.1
Net Clock Source Table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NetClockSourceEntry

netClockSourceEntry 1.3.6.1.4.1.193.96.115.3.6.1.1
This entity represents a net clock source for circuit emulation synchronization.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NetClockSourceEntry  

netClockSourceSystemNodeIndex 1.3.6.1.4.1.193.96.115.3.6.1.1.1
System node used for synchronization.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

netClockSourceSubrack 1.3.6.1.4.1.193.96.115.3.6.1.1.2
Subrack used for synchronization
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

netClockSourceSlot 1.3.6.1.4.1.193.96.115.3.6.1.1.3
Slot used for synchronization
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

netClockSourcePort 1.3.6.1.4.1.193.96.115.3.6.1.1.4
Port used for synchronization
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

netClockSourceStatus 1.3.6.1.4.1.193.96.115.3.6.1.1.5
...
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER active(1), idle(2)  

netClockSourcePriorityList 1.3.6.1.4.1.193.96.115.3.6.1.1.6
Priority list used for synchronization. [Port1,Port2,Port3,Port4]
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

netClockSourceRevertiveMode 1.3.6.1.4.1.193.96.115.3.6.1.1.7
Revertive Mode used for synchronization. Value: revertive,not-revertive,not-used
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER revertive(1), not-revertive(2), not-used(3)  

netClockSourceTimeToRestore 1.3.6.1.4.1.193.96.115.3.6.1.1.8
Time to restore used for synchronization (9) not_used
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 9..900  

netClockSourceRowStatus 1.3.6.1.4.1.193.96.115.3.6.1.1.9
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  RowStatus