ARMILLAIRE2000-MIB

File: ARMILLAIRE2000-MIB.mib (242874 bytes)

Imported modules

RFC-1215 RFC1155-SMI RFC-1212
RFC1213-MIB

Imported symbols

TRAP-TYPE enterprises Counter
Gauge IpAddress TimeTicks
OBJECT-TYPE DisplayString

Defined Types

RowStatus  
INTEGER createandwait(5), destroy(6), active(1), notinservice(2), notready(3), modified(17), up(22), down(23), outofservice(18)    

LrnRowStatus  
INTEGER createandwait(5), destroy(6), active(1), notinservice(2), notready(3), outofservice(18)    

CktRowStatus  
INTEGER createandwait(5), destroy(6), active(1), notinservice(2), notready(3), modified(17), up(22), down(23), modifytimer(99), outofservice(18), block(20)    

TmrRowStatus  
INTEGER modifytimer(99), active(1), notinservice(2), notready(3), modified(17), up(22), down(23), outofservice(18)    

UserLoginStatus  
INTEGER login(1), logininvalid(2), adduser(3), deleteuser(4)    

UserLoginPriority  
INTEGER admin(1), cts(2), user(8738)    

ProcessStatus  
INTEGER down(1), active(34), standby(51), outofservice(170), switchingover(3), unknown(172)    

IsdnPriority  
INTEGER primary(0), secondary(1), bearing(2)    

IsdnType  
INTEGER nfas(1), fas(0)    

OpStatus  
INTEGER active(1), down(23)    

LinkOpStatus  
INTEGER active(1), down(23), inhibit(19)    

LinkSetOpStatus  
INTEGER active(1), deactive(23)    

CktOpStatus  
INTEGER active(1), down(23), block(20)    

IsdnTrnkOpStatus  
INTEGER active(1), down(23), disable(21)    

ModifyTmrStatus  
INTEGER modifytimer(99), noaction(0)    

IfType  
INTEGER interface-t1(0), interface-t3(1), interface-ut3(2), interface-oc3(3), interface-ut3cp(4), interface-oc3cp(5), interface-e1(8), interface-hde1(9), interface-une3(10), interface-stm(11), interface-oc3aps(12), interface-stm1aps(13)    

AtmIfType  
INTEGER interface-t1(0), interface-e1(8)    

ConnectionType  
INTEGER t3(1), ut3(2), e3(10)    

EnableStatus  
INTEGER yes(1), no(2)    

Ss7RouteType  
INTEGER load(0)    

AddrIdentifier  
INTEGER unknown(2), nationalnumber(3)    

AddrType  
INTEGER callpartynum(1), transitnetwork(2)    

NumPlan  
INTEGER nonumber(0), isdnnumplan(1)    

Direction  
INTEGER in(0), out(1), both(2)    

EnableOperation  
INTEGER enable(16), disable(17)    

IsdnChnlMgtOperation  
INTEGER enable(11), disable(12)    

IsdnTrnkMgtOperation  
INTEGER enable(9), disable(10)    

BlockOperation  
INTEGER block(5), unblock(6), noaction(0)    

Level  
INTEGER level1(1), level2(2)    

ModemResetStatus  
INTEGER yes(1), no(0)    

ModemEnableStatus  
INTEGER enable(1), disable(0)    

MeasEnableStatus  
INTEGER enable(1), disable(0)    

EthernetConnStatus  
INTEGER up(1), down(2)    

Standard  
INTEGER ansi(65), itu(73), telmex(84)    

TrunkType  
INTEGER ss7(34), isdn(17)    

RouteType  
INTEGER ss7RouteType(1), isdnRouteType(2)    

AuditType  
INTEGER ansi(65), itu(73)    

AuditOperation  
INTEGER audit(1), noaction(0)    

Controlstatus  
INTEGER blockckt(5), unblock(6), enablechnl(11), disablechnl(12), noaction(0)    

LinkControlStatus  
INTEGER inhibitlink(1), uninhibitlink(2), noaction(0)    

LinkSetControlStatus  
INTEGER activatelnkset(3), deactivatelnkset(4), noaction(0)    

CircuitControlStatus  
INTEGER blockcic(7), unblockcic(8), queryckt(13), validateckt(14), resetckt(15), noaction(0)    

IsdnControlstatus  
INTEGER enabletrnk(9), disabletrnk(10), noaction(0)    

MtpRteState  
INTEGER rteavail(1), rteunaval(0)    

Bool  
INTEGER yes(1), no(0)    

LoadBalance  
INTEGER disable(0), enable(1)    

TrnkGrpType  
INTEGER ss7(32), isdn(33)    

ActiveAlarmAckStatus  
INTEGER clear(0), noaction(1)    

EventType  
INTEGER alarm(1), emergency(2), audit(3), diagnostics(4), security(5), maintenance(6)    

AlarmEvent  
INTEGER general(1), device(2), protocol(3), mfd(4), cdr(5), measurement(6), log(7), ig(8), faultTolerance(9), nomainevent(0)    

AlarmSubEvent  
INTEGER administration(1), nosubevent(0), operation(2), mssc(3), xconnect(4), hub(5), ss7lnk(6), ss7Br(7), isdn(8), atm(9)    

AlarmSeverity  
INTEGER critical(1), major(2), minor(3), informational(4)    

RoffType  
INTEGER le(1), tandem(2), intlgateway(3)    

NameString  
DisplayString Size(1..24)    

AddrString  
DisplayString Size(1..24)    

CdrFlag  
INTEGER noCdr(0), ic(1), og(2), bi(3)    

DSPCardType  
INTEGER dsp2B(1), dsp2C(2)    

VoicePcm  
INTEGER alaw(101), ulaw(102)    

TGFeature  
INTEGER enable(1), disable(0)    

FTswitchOver  
INTEGER ftsig(0), fticc(1), ftisdn(2), ftsphr(3), ftlm(4)    

LogFileAttr  
INTEGER alarmlog(3), auditlog(2), measlog(7), diaglog(1), scrtylog(4), eventlog(5), billlog(8), emplog(6)    

LogFileEnDis  
INTEGER alarmlog(3), auditlog(2), measlog(7), diaglog(1), scrtylog(4), eventlog(5), billlog(8), emplog(6), logall(11), noaction(0)    

SwitchType  
INTEGER national(0), international(1)    

LinkType  
INTEGER speed-56K(53), speed-64K(54)    

LogType  
INTEGER on(49), off(48)    

EnableTrace  
INTEGER enable(1), disable(0)    

TrunkState  
INTEGER idle(0), unEquipped(255), cP-Busy(1), maintainance-Busy(2)    

MeasPurgeFlag  
INTEGER autoOff(0), autoOn(1)    

E1MultiFrame  
INTEGER cas(1), ccs(2)    

E1CRC4  
INTEGER enabled(1), disabled(2)    

TransClkSrc  
INTEGER loopTiming(1), localTiming(2)    

DS1LineType  
INTEGER esF(1), d4(2)    

DS1LineCoding  
INTEGER b8zs(1), ami(2)    

DS1LBO  
INTEGER upTo133Feet(1), upTo266Feet(2), upTo399Feet(3), upTo533Feet(4), upTo655Feet(5), negative7-5Db(6), negative15Db(7), negative22-5Db(8)    

DS3LineType  
INTEGER cbitParity(1), clearChannel(2)    

DS3LBO  
INTEGER short(1), long(2)    

DS3ATMCellMap  
INTEGER plcp(1), directMapping(2)    

TimerType  
INTEGER ansi(1), itu(2)    

SwitchPcEntry  
SEQUENCE    
  switchPc INTEGER
  switchPcMode Standard
  switchPcStatus RowStatus

SwitchUserCfgEntry  
SEQUENCE    
  switchUserId INTEGER
  switchUserName NameString
  switchUserPassword NameString
  switchUserPriority UserLoginPriority
  switchUserStatus UserLoginStatus

Ss7LinkCfgEntry  
SEQUENCE    
  ss7LinkName NameString
  ss7LinkId INTEGER
  ss7LinkTrunkId INTEGER
  ss7LinkChannel INTEGER
  ss7LinkSlc INTEGER
  ss7LinkSpeed LinkType
  ss7LinkMode Standard
  ss7LinkRowStatus RowStatus
  ss7LinkOpStatus LinkOpStatus

Ss7AtmLinkCfgEntry  
SEQUENCE    
  ss7AtmVpi INTEGER
  ss7AtmVci INTEGER
  ss7AtmLnkId INTEGER
  ss7AtmXconnectId INTEGER
  ss7AtmSlotId INTEGER
  ss7AtmPortId INTEGER
  ss7AtmChnlId INTEGER
  ss7AtmTrnkId INTEGER
  ss7AtmPhyType AtmIfType
  ss7AtmLinkRowStatus RowStatus
  ss7AtmLinkOpStatus LinkOpStatus

Ss7LinksetCfgEntry  
SEQUENCE    
  ss7LinksetLinkId INTEGER
  ss7LinksetId INTEGER
  ss7LinksetName NameString
  ss7LinksetAdjDpc INTEGER
  ss7LinksetMode Standard
  ss7LinksetRowStatus RowStatus
  ss7LinksetOpStatus LinkSetOpStatus

Ss7LinksetMgmtEntry  
SEQUENCE    
  linksetId INTEGER
  linksetLevel Level
  linksetMgmntCmd LinkSetControlStatus

Ss7LinkMgmntEntry  
SEQUENCE    
  linkName NameString
  linkMgmntCmd LinkControlStatus

TrunkGrpCfgEntry  
SEQUENCE    
  trunkGrpId INTEGER
  trunkGrpName DisplayString
  trunkGrpCarrierId INTEGER
  trunkGrpType TrnkGrpType
  trunkGrpRoffName NameString
  trunkGrpRoffType RoffType
  trunkGrpCdrFlag CdrFlag
  trunkGrpNoOfTrunks INTEGER
  trunkGrpVoicePcm VoicePcm
  trunkGrpRowStatus RowStatus
  trunkGrpOpStatus OpStatus

Ss7TrunkCfgEntry  
SEQUENCE    
  ss7TrunkId INTEGER
  ss7TrunkName NameString
  ss7TrunkGrpId INTEGER
  ss7TrunkXconnectId INTEGER
  ss7TrunkSlotId INTEGER
  ss7TrunkPortId INTEGER
  ss7TrunkOpc INTEGER
  ss7TrunkDpc INTEGER
  ss7TrunkPhyType IfType
  ss7TrunkMode Standard
  ss7TrunkE1MultiFrame E1MultiFrame
  ss7TrunkE1CRC4 E1CRC4
  ss7TrunkE1TransClk TransClkSrc
  ss7TrunkDS1LineType DS1LineType
  ss7TrunkDS1LineCoding DS1LineCoding
  ss7TrunkDS1TransClkSrc TransClkSrc
  ss7TrunkDS1LBO DS1LBO
  ss7TrunkDS3LineType DS3LineType
  ss7TrunkDS3TransClkSrc TransClkSrc
  ss7TrunkDS3LBO DS3LBO
  ss7TrunkDS3DS1LineType DS1LineType
  ss7TrunkDS3DS1TransClkSrc TransClkSrc
  ss7TrunkOC3TransClkSrc TransClkSrc
  ss7TrunkUNCHE3TransClkSrc TransClkSrc
  ss7TrunkDS3ATMLineType DS3LineType
  ss7TrunkDS3ATMCellMap DS3ATMCellMap
  ss7TrunkDS3ATMTransClkSrc TransClkSrc
  ss7TrunkDS3ATMLBO DS3LBO
  ss7TrunkRowStatus RowStatus
  ss7TrunkOpStatus OpStatus

Ss7CktCfgEntry  
SEQUENCE    
  ss7CktTrunkId INTEGER
  ss7CktChnlId INTEGER
  ss7CktId INTEGER
  ss7CktDpc INTEGER
  ss7CktCic INTEGER
  ss7CktDir Direction
  ss7CktPriority INTEGER
  ss7CktT3 INTEGER
  ss7CktT12 INTEGER
  ss7CktT13 INTEGER
  ss7CktT14 INTEGER
  ss7CktT15 INTEGER
  ss7CktT16 INTEGER
  ss7CktT17 INTEGER
  ss7CktTVal INTEGER
  ss7CktRowStatus CktRowStatus
  ss7CktOpStatus CktOpStatus

Ss7CicTmrEntry  
SEQUENCE    
  ss7CktTmrDpc INTEGER
  ss7CktTmrCic INTEGER
  ss7CktTmrT3 INTEGER
  ss7CktTmrT12 INTEGER
  ss7CktTmrT13 INTEGER
  ss7CktTmrT14 INTEGER
  ss7CktTmrT15 INTEGER
  ss7CktTmrT16 INTEGER
  ss7CktTmrT17 INTEGER
  ss7CktTmrTVal INTEGER
  ss7CktTmrRowStatus ModifyTmrStatus

Ss7BCktCfgEntry  
SEQUENCE    
  ss7BCktVpi INTEGER
  ss7BCktVci INTEGER
  ss7BCktTrunkId INTEGER
  ss7BCktDpc INTEGER
  ss7BCktCic INTEGER
  ss7BCktDir Direction
  ss7BCktPriority INTEGER
  ss7BCktT3 INTEGER
  ss7BCktT12 INTEGER
  ss7BCktT13 INTEGER
  ss7BCktT14 INTEGER
  ss7BCktT15 INTEGER
  ss7BCktT16 INTEGER
  ss7BCktT17 INTEGER
  ss7BCktTVal INTEGER
  ss7BCktRowStatus CktRowStatus
  ss7BCktOpStatus CktOpStatus

Ss7CktMgmntEntry  
SEQUENCE    
  ss7CktMgmntTrnkId INTEGER
  ss7CktMgmntChnlId INTEGER
  ss7CktMgmntRepNum INTEGER
  ss7CktMgmntCmd BlockOperation

Ss7CICMgmntEntry  
SEQUENCE    
  ss7CktMgmtDPC INTEGER
  ss7CktMgmtCIC INTEGER
  ss7CktRepNum INTEGER
  ss7CicRange INTEGER
  ss7CICMgmntCmd CircuitControlStatus

Mtp2LinkTmrCfgEntry  
SEQUENCE    
  mtp2LinkId INTEGER
  mtp2T1 INTEGER
  mtp2T2 INTEGER
  mtp2T3 INTEGER
  mtp2T4n INTEGER
  mtp2T4e INTEGER
  mtp2T5 INTEGER
  mtp2T6 INTEGER
  mtp2T7 INTEGER
  mtp2RowStatus TmrRowStatus
  mtp2OpStatus OpStatus

Mtp3LinkCfgEntry  
SEQUENCE    
  mtp3LinkId INTEGER
  mtp3T1 INTEGER
  mtp3T2 INTEGER
  mtp3T3 INTEGER
  mtp3T4 INTEGER
  mtp3T5 INTEGER
  mtp3T6 INTEGER
  mtp3T7 INTEGER
  mtp3T12 INTEGER
  mtp3T13 INTEGER
  mtp3T14 INTEGER
  mtp3T17 INTEGER
  mtp3T22 INTEGER
  mtp3T23 INTEGER
  mtp3T24 INTEGER
  mtp3T31 INTEGER
  mtp3T32 INTEGER
  mtp3T33 INTEGER
  mtp3T34 INTEGER
  mtp3T35 INTEGER
  mtp3T36 INTEGER
  mtp3T37 INTEGER
  mtp3TFLC INTEGER
  mtp3TBND INTEGER
  mtp3RowStatus TmrRowStatus
  mtp3OpStatus OpStatus

IsupTimerCfgEntry  
SEQUENCE    
  isupTimerType TimerType
  isupTmrT1 INTEGER
  isupTmrT2 INTEGER
  isupTmrT5 INTEGER
  isupTmrT6 INTEGER
  isupTmrT7 INTEGER
  isupTmrT8 INTEGER
  isupTmrT9 INTEGER
  isupTmrT18 INTEGER
  isupTmrT19 INTEGER
  isupTmrT20 INTEGER
  isupTmrT21 INTEGER
  isupTmrT22 INTEGER
  isupTmrT23 INTEGER
  isupTmrT27 INTEGER
  isupTmrT28 INTEGER
  isupTmrT31 INTEGER
  isupTmrT33 INTEGER
  isupTmrT34 INTEGER
  isupTmrT36 INTEGER
  isupTmrTCCR INTEGER
  isupTmrTEX INTEGER
  isupTmrTCRM INTEGER
  isupTmrTCRA INTEGER
  isupTmrTCCRt INTEGER
  isupTmrTECt INTEGER
  isupTmrTGTCHG INTEGER
  isupTmrTGRES INTEGER
  isupTmrTFGR INTEGER
  isupTmrTRELRSP INTEGER
  isupTmrTFNLRELRS INTEGER
  isupTimerRowStatus ModifyTmrStatus

Ss7RtDpcEntry  
SEQUENCE    
  ss7RtDPC INTEGER
  ss7RtCmbLinksetId INTEGER
  ss7RtLoadShareType Standard
  ss7RtRowStatus RowStatus
  ss7RtOpStatus OpStatus

IsdnTmrCfgEntry  
SEQUENCE    
  isdnTnkId INTEGER
  isdnTmrT301 INTEGER
  isdnTmrT302 INTEGER
  isdnTmrT303 INTEGER
  isdnTmrT304 INTEGER
  isdnTmrT305 INTEGER
  isdnTmrT306 INTEGER
  isdnTmrT307 INTEGER
  isdnTmrT308 INTEGER
  isdnTmrT310 INTEGER
  isdnTmrT311 INTEGER
  isdnTmrT312 INTEGER
  isdnTmrT313 INTEGER
  isdnTmrT316 INTEGER
  isdnTmrT318 INTEGER
  isdnTmrT319 INTEGER
  isdnTmrT322 INTEGER
  isdnTmrT316C INTEGER
  isdnTmrT330 INTEGER
  isdnTmrT331 INTEGER
  isdnTmrT332 INTEGER
  isdnTmrTRST INTEGER
  isdnTmrTREST INTEGER
  isdnTmrTANS INTEGER
  isdnTmrT396 INTEGER
  isdnTmrT397 INTEGER
  isdnTrnkTmrRowStatus TmrRowStatus
  isdnTrnkTmrOpStatus OpStatus

IsdnTrunkCfgEntry  
SEQUENCE    
  isdnTrunkId INTEGER
  isdnTrunkName NameString
  isdnTrunkGrpId INTEGER
  isdnDchnlId INTEGER
  isdnTrunkType IsdnType
  isdnXconnectId INTEGER
  isdnSlotId INTEGER
  isdnPortId INTEGER
  isdnDirection Direction
  isdnPriority IsdnPriority
  isdnDurthreshold INTEGER
  isdnCntthreshold INTEGER
  isdnPhyIntfType IfType
  isdnDchnlTimeSlot INTEGER
  isdnE1MultiFrame E1MultiFrame
  isdnE1CRC4 E1CRC4
  isdnE1TransClk TransClkSrc
  isdnDS1LineType DS1LineType
  isdnDS1LineCoding DS1LineCoding
  isdnDS1TransClkSrc TransClkSrc
  isdnDS1LBO DS1LBO
  isdnDS3LineType DS3LineType
  isdnDS3TransClkSrc TransClkSrc
  isdnDS3LBO DS3LBO
  isdnDS3DS1LineType DS1LineType
  isdnDS3DS1TransClkSrc TransClkSrc
  isdnTrunkRowStatus RowStatus
  isdnTrunkOpStatus IsdnTrnkOpStatus

IsdnChnlStatusCfgEntry  
SEQUENCE    
  isdnStatusTrunkId INTEGER
  isdnStatusChnlId INTEGER
  isdnStatusChnlState TrunkState
  isdnStatusChnlAllocMeth INTEGER
  isdnStatusChnlSuConnId INTEGER

IsdnTrnkMgmntEntry  
SEQUENCE    
  isdnTrnkMgmntId INTEGER
  isdnTrnkMgmntCmd IsdnTrnkMgtOperation

IsdnChnlMgmntEntry  
SEQUENCE    
  isdnTrunkMgmntId INTEGER
  isdnChnlMgmntId INTEGER
  isdnChnlMgmntCmd IsdnChnlMgtOperation

MfdMgmntEntry  
SEQUENCE    
  isdnTnkMgmntId INTEGER
  isdnDurThreshold INTEGER
  isdnCntThreshold INTEGER
  mfdMgmntCmd EnableOperation

RouteEntry  
SEQUENCE    
  routeId INTEGER
  routeAddrType AddrType
  routeAdrId AddrIdentifier
  routeAddr AddrString
  routeNumPlan NumPlan
  routeNumOfDigit INTEGER
  routeRouteName NameString
  routeRouteType RouteType
  routeRowStatus RowStatus
  routeOpStatus OpStatus

RtEntryIsdnCfgEntry  
SEQUENCE    
  rtEntryIsdnGrpId INTEGER
  rtEntryIsdntrunkId INTEGER
  rtEntryIsdnRouteName NameString
  rtEntryIsdnRowStatus RowStatus
  rtEntryIsdnOpStatus OpStatus

RtEntrySs7CfgEntry  
SEQUENCE    
  rtEntrySs7GrpId INTEGER
  rtEntrySs7CmbLinksetId INTEGER
  rtEntrySs7RouteName NameString
  rtEntrySs7Dpc INTEGER
  rtEntrySs7Mode Standard
  rtEntrySs7RowStatus RowStatus
  rtEntrySs7OpStatus OpStatus

DigitStripMgmntEntry  
SEQUENCE    
  rtName NameString
  rtAddrType AddrIdentifier
  rtNumOfDigit INTEGER
  rtMgmntCmd EnableOperation

IsdnLoadBalanceMgmntEntry  
SEQUENCE    
  rteName NameString
  ilbMgmntCmd EnableOperation

MeasTrnkGrpTrafficEntry  
SEQUENCE    
  measTrnkGrpName DisplayString
  measTrnkGrpDataSuspect INTEGER
  measTrnkGrpincomingUsage INTEGER
  measTrnkGrpoutgoingUsage INTEGER
  measTrnkGrpISCicsChnls INTEGER
  measTrnkGrpOOSCicsChnls INTEGER
  measTrnkGrptotalUsage INTEGER
  measTrnkGrpmaintainanceUsage INTEGER

MeasLinkTrafficEntry  
SEQUENCE    
  measLinkName NameString
  measLinkDataSuspect INTEGER
  measLinkUnavailableDuration INTEGER
  measLinkInServiceDuration INTEGER
  measLinkMSUsRetransmitted INTEGER
  measLinkOctetsReceived INTEGER
  measLinkOctectsTransmitted INTEGER
  measLinkLostMSUsBufferOverflow INTEGER
  measLinkMSUsDiscarded INTEGER

XconnectCfgEntry  
SEQUENCE    
  xconnectId INTEGER
  xconnectName NameString
  xconnectIPAddr IpAddress
  xconnectTCPPort INTEGER
  xconnectRowStatus RowStatus
  xconnectOpStatus OpStatus

XlinkCfgEntry  
SEQUENCE    
  xconnectIdEndA INTEGER
  slotIdEndA INTEGER
  portIdEndA INTEGER
  xconnectIdEndB INTEGER
  slotIdEndB INTEGER
  portIdEndB INTEGER
  xlinkConnectionType ConnectionType
  xlinkRowStatus RowStatus
  xlinkOpStatus OpStatus

XlinkMgmntEntry  
SEQUENCE    
  xconnIdEndA INTEGER
  xconnSlotIdEndA INTEGER
  xconnPortIdEndA INTEGER
  xconnIdEndB INTEGER
  xconnSlotIdEndB INTEGER
  xconnPortIdEndB INTEGER
  xlinkMgmntCmd EnableOperation

CdrMngmtTrnkGrpEntry  
SEQUENCE    
  cdrTrnkGrpId INTEGER
  cdrTrnkGrpdirection CdrFlag
  cdrTrnkGrpMgmntCmd EnableOperation

ModemStatusEntry  
SEQUENCE    
  faultModemTrnkId INTEGER
  faultModemChnlId INTEGER
  faultModemRepnum INTEGER
  faultModemReset ModemResetStatus

LrnEntry  
SEQUENCE    
  lrnNum DisplayString
  lrnRowStatus LrnRowStatus

SwitchDSPCfgEntry  
SEQUENCE    
  switchDSPXconnId INTEGER
  switchDSPSlotId INTEGER
  switchDSPCardType DSPCardType
  switchDSPCfgRowStatus RowStatus
  switchDSPCfgOpStatus OpStatus

SwitchFeatureTGCfgEntry  
SEQUENCE    
  switchFeatureTGId INTEGER
  switchFeatureTGName NameString
  switchFeatureTGType TrnkGrpType
  switchFeatureTGFeatureEC TGFeature
  switchFeatureTGFeatureCOMPRESS TGFeature
  switchFeatureTGFeatureSS TGFeature
  switchFeatureTGFeatureCNIS TGFeature

Ss7LnkTraceEntry  
SEQUENCE    
  ss7LnkId INTEGER
  ss7LnkLog LogType
  ss7LnkEnable EnableTrace

Ss7RouteTraceEntry  
SEQUENCE    
  ss7RouteDpc INTEGER
  ss7RouteLog LogType
  ss7RouteEnable EnableTrace

IsdntrunkTraceEntry  
SEQUENCE    
  isdnTrnkId INTEGER
  isdnTrunkLog LogType
  isdnTrunkEnable EnableTrace

AuditISDNTrnkCfgEntry  
SEQUENCE    
  auditTrnkId INTEGER
  auditISDNTrnk AuditOperation

AuditDPCCfgEntry  
SEQUENCE    
  auditPointCode INTEGER
  auditPointCodeType AuditType
  auditDPC AuditOperation

SwitchActiveAlarmEntry  
SEQUENCE    
  switchAlarmMsgId INTEGER
  switchAlarmInstNo INTEGER
  switchAlarmTime DisplayString
  switchAlarmType EventType
  switchAlarmMainEvent AlarmEvent
  switchAlarmSubEvent AlarmSubEvent
  switchAlarmId INTEGER
  switchAlarmSeverity AlarmSeverity
  switchAlarmDesc DisplayString
  switchAlarmAck ActiveAlarmAckStatus
  switchAlarmRepeatTime INTEGER

Defined Values

armillaire 1.3.6.1.4.1.4618
OBJECT IDENTIFIER    

products 1.3.6.1.4.1.4618.1
OBJECT IDENTIFIER    

services 1.3.6.1.4.1.4618.2
OBJECT IDENTIFIER    

armillaire2000 1.3.6.1.4.1.4618.1.2
OBJECT IDENTIFIER    

switchInfo 1.3.6.1.4.1.4618.1.2.1
OBJECT IDENTIFIER    

switchConfig 1.3.6.1.4.1.4618.1.2.2
OBJECT IDENTIFIER    

switchMeas 1.3.6.1.4.1.4618.1.2.3
OBJECT IDENTIFIER    

switchCdr 1.3.6.1.4.1.4618.1.2.4
OBJECT IDENTIFIER    

switchFeature 1.3.6.1.4.1.4618.1.2.5
OBJECT IDENTIFIER    

switchMaintenance 1.3.6.1.4.1.4618.1.2.6
OBJECT IDENTIFIER    

switchTrap 1.3.6.1.4.1.4618.1.2.7
OBJECT IDENTIFIER    

switchGenInfoGrp 1.3.6.1.4.1.4618.1.2.1.1
OBJECT IDENTIFIER    

switchPcInfo 1.3.6.1.4.1.4618.1.2.1.2
OBJECT IDENTIFIER    

switchUsrInfo 1.3.6.1.4.1.4618.1.2.1.3
OBJECT IDENTIFIER    

switchVersionGrp 1.3.6.1.4.1.4618.1.2.1.4
OBJECT IDENTIFIER    

ss7 1.3.6.1.4.1.4618.1.2.2.1
OBJECT IDENTIFIER    

isdn 1.3.6.1.4.1.4618.1.2.2.2
OBJECT IDENTIFIER    

trnkGrp 1.3.6.1.4.1.4618.1.2.2.3
OBJECT IDENTIFIER    

rt 1.3.6.1.4.1.4618.1.2.2.4
OBJECT IDENTIFIER    

xconnect 1.3.6.1.4.1.4618.1.2.2.5
OBJECT IDENTIFIER    

enableGroup 1.3.6.1.4.1.4618.1.2.2.6
OBJECT IDENTIFIER    

measFile 1.3.6.1.4.1.4618.1.2.3.1
OBJECT IDENTIFIER    

measSwitch 1.3.6.1.4.1.4618.1.2.3.2
OBJECT IDENTIFIER    

measTrnkGrp 1.3.6.1.4.1.4618.1.2.3.3
OBJECT IDENTIFIER    

measLnk 1.3.6.1.4.1.4618.1.2.3.4
OBJECT IDENTIFIER    

modemFaultDetection 1.3.6.1.4.1.4618.1.2.5.1
OBJECT IDENTIFIER    

lnp 1.3.6.1.4.1.4618.1.2.5.2
OBJECT IDENTIFIER    

switchDSP 1.3.6.1.4.1.4618.1.2.5.3
OBJECT IDENTIFIER    

switchTGFeature 1.3.6.1.4.1.4618.1.2.5.4
OBJECT IDENTIFIER    

ft 1.3.6.1.4.1.4618.1.2.6.1
OBJECT IDENTIFIER    

log 1.3.6.1.4.1.4618.1.2.6.2
OBJECT IDENTIFIER    

trace 1.3.6.1.4.1.4618.1.2.6.3
OBJECT IDENTIFIER    

processStatus 1.3.6.1.4.1.4618.1.2.6.4
OBJECT IDENTIFIER    

ethernetConnStatusInfo 1.3.6.1.4.1.4618.1.2.6.5
OBJECT IDENTIFIER    

audit 1.3.6.1.4.1.4618.1.2.6.6
OBJECT IDENTIFIER    

trapObjects 1.3.6.1.4.1.4618.1.2.7.1
OBJECT IDENTIFIER    

alarmGrp 1.3.6.1.4.1.4618.1.2.7.2
OBJECT IDENTIFIER    

ftSwitchOverInfo 1.3.6.1.4.1.4618.1.2.6.1.1
OBJECT IDENTIFIER    

logFileInfo 7.1
OBJECT IDENTIFIER    

logFileGenEnable 7.2
OBJECT IDENTIFIER    

logFileAttribute 7.3
OBJECT IDENTIFIER    

auditInfo 1.1
OBJECT IDENTIFIER    

ss7LnkTrace 1.3.6.1.4.1.4618.1.2.6.3.1
OBJECT IDENTIFIER    

ss7RouteTrace 1.3.6.1.4.1.4618.1.2.6.3.2
OBJECT IDENTIFIER    

isdnTrnkTrace 1.3.6.1.4.1.4618.1.2.6.3.3
OBJECT IDENTIFIER    

processStatusInfo 1.3.6.1.4.1.4618.1.2.6.4.1
OBJECT IDENTIFIER    

ss7Sig 34.1
OBJECT IDENTIFIER    

ss7Br 34.2
OBJECT IDENTIFIER    

mtp2 34.3
OBJECT IDENTIFIER    

mtp3 34.4
OBJECT IDENTIFIER    

isup 34.5
OBJECT IDENTIFIER    

ss7Route 34.6
OBJECT IDENTIFIER    

mtp3GenTmrCfgGroup 34.4.1
OBJECT IDENTIFIER    

switchName 1.3.6.1.4.1.4618.1.2.1.1.1
The switch Name. Can be any combination of alphanumeric characters. Spaces are not allowed and cannot exceed 24 characters
Status: mandatory Access: read-write
OBJECT-TYPE    
  NameString  

switchDescr 1.3.6.1.4.1.4618.1.2.1.1.2
Description of the Switch. Can be any combination of alphanumeric characters. Spaces are allowed and cannot exceed 255 characters.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..255)  

switchLocation 1.3.6.1.4.1.4618.1.2.1.1.3
Location of the Switch. Can be any combination of alphanumeric characters. Spaces are allowed and cannot exceed 255 characters.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..255)  

switchContact 1.3.6.1.4.1.4618.1.2.1.1.4
Contact information about the Switch. Can be any combination of alphanumeric characters. Spaces are allowed and cannot exceed 24 characters.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..24)  

switchIPAddr 1.3.6.1.4.1.4618.1.2.1.1.5
Switch IP address. In xxx.xxx.xxx.xxx format.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

switchUpTime 1.3.6.1.4.1.4618.1.2.1.1.6
The Time (in Seconds) since last restart of the Switch
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

switchVersion 1.3.6.1.4.1.4618.1.2.1.1.7
The version of current Switch
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..24)  

switchVerDescr 1.3.6.1.4.1.4618.1.2.1.1.8
The description of switch version
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..255)  

systemDescr 1.3.6.1.4.1.4618.1.2.1.1.9
The description of the System
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..255)  

switchType 1.3.6.1.4.1.4618.1.2.1.1.10
The Switch Type : (National/International)
Status: mandatory Access: read-only
OBJECT-TYPE    
  SwitchType  

switchNameStatus 1.3.6.1.4.1.4618.1.2.1.1.11
Current Status (configurational Status) of this Switch Name. To Configure this Link, the only option is 'CREATEANDWAIT' To Delete this Link, the only option is 'DESTROY' For the GET Operation, the possible options are 1) active 2) notinservice 3) no
Status: mandatory Access: read-write
OBJECT-TYPE    
  RowStatus  

switchPcInfoTable 1.3.6.1.4.1.4618.1.2.1.2.1
Switch Point code Information Table.The index of this table is switchPc (Integer).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SwitchPcEntry

switchPcEntry 1.3.6.1.4.1.4618.1.2.1.2.1.1
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SwitchPcEntry  

switchPc 1.3.6.1.4.1.4618.1.2.1.2.1.1.1
Point Code for the switch (the Integer Value). The Point Code should be converted into its Integer equivalent. For Example: 0-1-1 is converted as 257 (for ANSI) 0-1-2 is converted as 10 (for ITU)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..16777215  

switchPcMode 1.3.6.1.4.1.4618.1.2.1.2.1.1.2
Point Code type (ANSI/ITU)
Status: mandatory Access: read-write
OBJECT-TYPE    
  Standard  

switchPcStatus 1.3.6.1.4.1.4618.1.2.1.2.1.1.3
Current Status (configurational Status) of this Switch Point Code. To Configure this Link, the only option is 'CREATEANDWAIT' To Delete this Link, the only option is 'DESTROY' For the 'GET' Operation, the possible options are 1) active 2) notinservic
Status: mandatory Access: read-write
OBJECT-TYPE    
  RowStatus  

switchUserCfgTable 1.3.6.1.4.1.4618.1.2.1.3.1
This Table is to maintain the User information and providing Validation Checks for Authorised users for Configuration.The index of this table is switchUserId (Integer). CURRENTLY NOT APPLICABLE
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SwitchUserCfgEntry

switchUserCfgEntry 1.3.6.1.4.1.4618.1.2.1.3.1.1
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. CURRENTLY NOT APPLICABLE
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SwitchUserCfgEntry  

switchUserId 1.3.6.1.4.1.4618.1.2.1.3.1.1.1
The Id of the Switch User. The user can only 'SET' User Id. If user tries to 'GET' the user Id, incorrect value would be displayed. This Feature is CURRENTLY NOT APPLICABLE
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

switchUserName 1.3.6.1.4.1.4618.1.2.1.3.1.1.2
The NAME of the Switch User. The user can only 'SET' User NAME. If user tries to 'GET' the user Id, incorrect value would be displayed. This Feature is CURRENTLY NOT APPLICABLE
Status: mandatory Access: read-write
OBJECT-TYPE    
  NameString  

switchUserPassword 1.3.6.1.4.1.4618.1.2.1.3.1.1.3
The PASSWORD of the Switch User. This is in an encrypted format. This is not visible to user.The user can only set password . This Feature is CURRENTLY NOT APPLICABLE
Status: mandatory Access: read-write
OBJECT-TYPE    
  NameString  

switchUserPriority 1.3.6.1.4.1.4618.1.2.1.3.1.1.4
The PRIORITY of the Switch User. User Priority by default is ADMINISTRATOR. This Feature is CURRENTLY NOT APPLICABLE
Status: mandatory Access: read-write
OBJECT-TYPE    
  UserLoginPriority  

switchUserStatus 1.3.6.1.4.1.4618.1.2.1.3.1.1.5
Checks whether user is a valid user. Only the user with administrative privilege can login. This Feature is CURRENTLY NOT APPLICABLE
Status: mandatory Access: read-write
OBJECT-TYPE    
  UserLoginStatus  

switchVerLM 1.3.6.1.4.1.4618.1.2.1.4.1
Switch's Process LM Version number
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

switchVerMTP2 1.3.6.1.4.1.4618.1.2.1.4.2
Switch's Process MPT2 Version number
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

switchVerICC 1.3.6.1.4.1.4618.1.2.1.4.3
Switch's Process ICC Version number
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

switchVerSIG 1.3.6.1.4.1.4618.1.2.1.4.4
Switch's Process SIG Version number
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

switchVerISDN 1.3.6.1.4.1.4618.1.2.1.4.5
Switch's Process ISDN Version number
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

switchVerSPHR 1.3.6.1.4.1.4618.1.2.1.4.6
Switch's Process SPHR Version number
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

ss7LinkCfgTable 34.1.1
SS7 Link Table. Information about the SS7 Link(s) in MSSC are provided in this table. The index of this table is ss7LinkName (String)
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ss7LinkCfgEntry

ss7LinkCfgEntry 34.1.1.1
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ss7LinkCfgEntry  

ss7LinkName 34.1.1.1.1
Link name. Can be any combination of alphanumeric characters. Spaces are not allowed and cannot exceed 15 characters.
Status: mandatory Access: read-write
OBJECT-TYPE    
  NameString  

ss7LinkId 34.1.1.1.2
User assigned Link id. Can be any integer 1-65535.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7LinkTrunkId 34.1.1.1.3
User assigned Trunk id.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7LinkChannel 34.1.1.1.4
User assigned channel.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7LinkSlc 34.1.1.1.5
Link Selection Code. Can be any integer 0-15.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

ss7LinkSpeed 34.1.1.1.6
SS7 Link Speed: Possible Values are: 56k or 64k. Default Value is 64K
Status: mandatory Access: read-only
OBJECT-TYPE    
  LinkType  

ss7LinkMode 34.1.1.1.7
Link Mode(ANSI/ITU)
Status: mandatory Access: read-write
OBJECT-TYPE    
  Standard  

ss7LinkRowStatus 34.1.1.1.8
Current Status (configurational Status) of this Link. To Configure this Link, the only option is 'CREATEANDWAIT' To Delete this Link, the only option is 'DESTROY' For the 'GET' Operation, the possible options are 1) active 2) notinservice 3) notread
Status: mandatory Access: read-write
OBJECT-TYPE    
  RowStatus  

ss7LinkOpStatus 34.1.1.1.9
Current Status (Operational Status) of this SS7 Link. 'SET' Operation is NOT APPLICABLE. For the 'GET' Operation, the possible options are 1) active 2) down 3) inhibit
Status: mandatory Access: read-only
OBJECT-TYPE    
  LinkOpStatus  

ss7AtmLinkCfgTable 34.1.2
SS7 Atm Link Table. Information about the Atm Link(s) in MSSC are provided in this table. This table has two indices. The indices are ss7AtmVpi and ss7AtmVci (both Integer).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ss7AtmLinkCfgEntry

ss7AtmLinkCfgEntry 34.1.2.1
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ss7AtmLinkCfgEntry  

ss7AtmVpi 34.1.2.1.1
Atmlink Virtual Path Identifier.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7AtmVci 34.1.2.1.2
Atmlink Virtual Channel Identifier.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7AtmLnkId 34.1.2.1.3
Atmlink Id.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7AtmXconnectId 34.1.2.1.4
Xconnect Id.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7AtmSlotId 34.1.2.1.5
Slot Id.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7AtmPortId 34.1.2.1.6
Port Id.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7AtmChnlId 34.1.2.1.7
Channel Id.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7AtmTrnkId 34.1.2.1.8
Atm Trunk Id.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7AtmPhyType 34.1.2.1.9
SS7 ATM Physical interface type. The value of this object could be 1) T1 (interface - t1) 2) E1 (interface - e1).
Status: mandatory Access: read-write
OBJECT-TYPE    
  AtmIfType  

ss7AtmLinkRowStatus 34.1.2.1.10
Current ATM Status (configurational Status) of this Link. To Configure this Link, the only option is 'CREATEANDWAIT' To Delete this Link, the only option is 'DESTROY' For the 'GET' Operation, the possible options are 1) active 2) notinservice 3) not
Status: mandatory Access: read-write
OBJECT-TYPE    
  RowStatus  

ss7AtmLinkOpStatus 34.1.2.1.11
Current Status (Operational Status) of this SS7 Atm Link. 'SET' Operation is NOT APPLICABLE. For the 'GET' Operation, the possible options are 1) active 2) down 3) inhibit
Status: mandatory Access: read-only
OBJECT-TYPE    
  LinkOpStatus  

ss7LinksetCfgTable 34.1.3
SS7 Linkset Table. Information about the Linkset(s) in MSSC are provided in this table. This table has the index ss7LinksetLinkId (Integer).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ss7LinksetCfgEntry

ss7LinksetCfgEntry 34.1.3.1
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ss7LinksetCfgEntry  

ss7LinksetLinkId 34.1.3.1.1
Link id. Can be any integer 1-65535.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7LinksetId 34.1.3.1.2
Linkset id. Can be any integer 1-128.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..128  

ss7LinksetName 34.1.3.1.3
Linkset name. Can be any combination of alphanumeric characters. Spaces are not allowed and cannot exceed 15 characters.
Status: mandatory Access: read-write
OBJECT-TYPE    
  NameString  

ss7LinksetAdjDpc 34.1.3.1.4
Adjacent Point Code for this Linkset (the Integer value). The Point Code should be converted into its Integer equivalent. For Example: 0-1-1 is converted as 257 (for ANSI) 0-1-2 is converted as 10 (for ITU)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..16777215  

ss7LinksetMode 34.1.3.1.5
Linkset Type(ANSI/ITU)
Status: mandatory Access: read-write
OBJECT-TYPE    
  Standard  

ss7LinksetRowStatus 34.1.3.1.6
Current Status (configurational Status) of this Link. To Configure this Link, the only option is 'CREATEANDWAIT' To Delete this Link, the only option is 'DESTROY' For the 'GET' Operation, the possible options are 1) active 2) notinservice 3) notread
Status: mandatory Access: read-write
OBJECT-TYPE    
  RowStatus  

ss7LinksetOpStatus 34.1.3.1.7
Current Status (Operational Status) of this Link Set. 'SET' Operation is NOT APPLICABLE. For the 'GET' Operation, the possible options are 1) active 2) deactive
Status: mandatory Access: read-only
OBJECT-TYPE    
  LinkSetOpStatus  

ss7LinksetMgmtTable 34.1.4
SS7 Linkset Management Table. The Management Commands for Linkset in MSSC are provided in this table. This table has the index linksetId (Integer).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ss7LinksetMgmtEntry

ss7LinksetMgmtEntry 34.1.4.1
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ss7LinksetMgmtEntry  

linksetId 34.1.4.1.1
SS7 Linkset Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

linksetLevel 34.1.4.1.2
This option deactivates the linkset at level 1 or level 2. Level 2 is for layer 2 only. The option available are: 1) Level 1 (level-1) [Default] 2) Level 2 (level-2)
Status: mandatory Access: read-write
OBJECT-TYPE    
  Level  

linksetMgmntCmd 34.1.4.1.3
Management Command for Activing/DeActiving call on this linkset. The possible options are : 1) Active 2) Deactive 3) Noaction [default]
Status: mandatory Access: read-write
OBJECT-TYPE    
  LinkSetControlStatus  

ss7LinkMgmntTable 34.1.5
SS7 Link Management Table. The Management Commands for Link(s) in MSSC are provided in this table. This table has the index linkName (String).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ss7LinkMgmntEntry

ss7LinkMgmntEntry 34.1.5.1
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ss7LinkMgmntEntry  

linkName 34.1.5.1.1
SS7 Link Name
Status: mandatory Access: read-only
OBJECT-TYPE    
  NameString  

linkMgmntCmd 34.1.5.1.2
Management Command for Inhibiting/UnInhibiting link. The possible options are : 1) Inhibit 2) UnInhibit 3) Noaction [default]
Status: mandatory Access: read-write
OBJECT-TYPE    
  LinkControlStatus  

trunkGrpCfgTable 1.3.6.1.4.1.4618.1.2.2.3.1
SS7/ISDN Trunk Group Table. The Information about Trunk Groups in MSSC are provided in this table. This table has the index trunkGrpId (Integer).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TrunkGrpCfgEntry

trunkGrpCfgEntry 1.3.6.1.4.1.4618.1.2.2.3.1.1
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  TrunkGrpCfgEntry  

trunkGrpId 1.3.6.1.4.1.4618.1.2.2.3.1.1.1
Denotes Id for this trunk group. Range for Id is 1-65535.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

trunkGrpName 1.3.6.1.4.1.4618.1.2.2.3.1.1.2
Denotes Name of this trunk group. The Name is a string of length 8. The first two characters of Name have to be alphabhets. The next 6 charecters are numeric. An example a valid Trunk Group Name is ab123456. NOTE: This format needs to be strictly foll
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..8)  

trunkGrpCarrierId 1.3.6.1.4.1.4618.1.2.2.3.1.1.3
Denotes Carrier id for this trunk group. The Carrier id Field is an integer of length 4. An example for Carried Id is: 1234 NOTE: The format for sertting the Carrier Id needs to strictly followed. Failure to follow this format will result in unsucces
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

trunkGrpType 1.3.6.1.4.1.4618.1.2.2.3.1.1.4
Denotes Trunk group type. Possible values for Trunk group are: 1. ss7 2. isdn
Status: mandatory Access: read-write
OBJECT-TYPE    
  TrnkGrpType  

trunkGrpRoffName 1.3.6.1.4.1.4618.1.2.2.3.1.1.5
Denotes Remote Office Name: NOTE: Value for this object is NOT Valid if TrunkGrpType is ISDN. Only Valid For SS7 TrunkGroup. If trunkGrpType is ISDN and the USER sets the value for Remote Office Name, then this Remote Office Name will be ignored when
Status: mandatory Access: read-write
OBJECT-TYPE    
  NameString  

trunkGrpRoffType 1.3.6.1.4.1.4618.1.2.2.3.1.1.6
Denotes Remote Office Type: NOTE: Value for this object is NOT Valid if TrunkGrpType is ISDN. Remote Office Type is only Valid For SS7 TrunkGroup.If trunkGrpType is ISDN and the USER sets the value for Remote Office Type, then this value is ignored w
Status: mandatory Access: read-write
OBJECT-TYPE    
  RoffType  

trunkGrpCdrFlag 1.3.6.1.4.1.4618.1.2.2.3.1.1.7
Denotes Cdr Flag : Possible values are: 0) noCdr -> default (No CDR file is required) 1) IC -> for Incoming calls 2) OG -> for Outgoing calls 3) BI -> for both the Incoming and outgoing calls
Status: mandatory Access: read-write
OBJECT-TYPE    
  CdrFlag  

trunkGrpNoOfTrunks 1.3.6.1.4.1.4618.1.2.2.3.1.1.8
Denotes the Number Of Trunks that are contained in this trunk Group
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

trunkGrpVoicePcm 1.3.6.1.4.1.4618.1.2.2.3.1.1.9
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  VoicePcm  

trunkGrpRowStatus 1.3.6.1.4.1.4618.1.2.2.3.1.1.10
Current Status (configurational Status) of this Trunk Group. To Configure this Link, the only option is 'CREATEANDWAIT' To Delete this Link, the only option is 'DESTROY' For the 'GET' Operation, the possible options are 1) active 2) notinservice 3)
Status: mandatory Access: read-write
OBJECT-TYPE    
  RowStatus  

trunkGrpOpStatus 1.3.6.1.4.1.4618.1.2.2.3.1.1.11
Current Status (Operational Status) of this Trunk Group. 'SET' Operation is NOT APPLICABLE. For the 'GET' Operation, the possible options are 1) active 2) down
Status: mandatory Access: read-only
OBJECT-TYPE    
  OpStatus  

ss7TrunkCfgTable 7.1
ISDN Trunk Table. The Information about ISDN Trunk(s) in MSSC are provided in this table. This table has the index ss7TrunkId (Integer).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ss7TrunkCfgEntry

ss7TrunkCfgEntry 7.1.1
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ss7TrunkCfgEntry  

ss7TrunkId 7.1.1.1
Id for the trunk. Can be any integer 1-65535.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7TrunkName 7.1.1.2
Name for the trunk. Can be any combination of alphanumeric characters. Spaces are not allowed and cannot exceed 15 characters.
Status: mandatory Access: read-write
OBJECT-TYPE    
  NameString  

ss7TrunkGrpId 7.1.1.3
Id of the trunk group to which the trunk belongs. Can be any integer 1-65535.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7TrunkXconnectId 7.1.1.4
Xconnect id
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7TrunkSlotId 7.1.1.5
Slot id
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7TrunkPortId 7.1.1.6
Port id
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7TrunkOpc 7.1.1.7
Originating point code (the Integer value). The Point Code should be converted into its Integer equivalent. For Example: 0-1-1 is converted as 257 (for ANSI) 0-1-2 is converted as 10 (for ITU)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..16777215  

ss7TrunkDpc 7.1.1.8
Destination point code ( the Integer Value). The Point Code should be converted into its Integer equivalent. For Example: 0-1-1 is converted as 257 (for ANSI) 0-1-2 is converted as 10 (for ITU)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..16777215  

ss7TrunkPhyType 7.1.1.9
Physical Interface Type possible options are 1) T1 (interface-t1) 2) T3 (interface-t3) 3) Unchannelized T3 (interface-ut3) 4) OC3 (interface-oc3) 5) Unchannelized T3 with compression (interface-ut3cp) 6) OC3 with compression (interface-oc3cp) 7) E
Status: mandatory Access: read-write
OBJECT-TYPE    
  IfType  

ss7TrunkMode 7.1.1.10
Trunk mode - ANSI/ITU
Status: mandatory Access: read-write
OBJECT-TYPE    
  Standard  

ss7TrunkE1MultiFrame 7.1.1.11
E1 multiFrame Type possible options are 1) CAS(1) 2) CCS(2)
Status: mandatory Access: read-write
OBJECT-TYPE    
  E1MultiFrame  

ss7TrunkE1CRC4 7.1.1.12
E1 Cyclic Redundancy Code, possible options are 1) enabled(1) 2) disable(2)
Status: mandatory Access: read-write
OBJECT-TYPE    
  E1CRC4  

ss7TrunkE1TransClk 7.1.1.13
E1 Transmit Clock Source, possible options are 1) loopTiming(1) 2) localTiming(2)
Status: mandatory Access: read-write
OBJECT-TYPE    
  TransClkSrc  

ss7TrunkDS1LineType 7.1.1.14
DS1 Line Type possible options are 1) esF(1) 2) d4(2)
Status: mandatory Access: read-write
OBJECT-TYPE    
  DS1LineType  

ss7TrunkDS1LineCoding 7.1.1.15
DS1 Line Coding, possible options are 1) b8zs(1) 2) ami(2)
Status: mandatory Access: read-write
OBJECT-TYPE    
  DS1LineCoding  

ss7TrunkDS1TransClkSrc 7.1.1.16
DS1 Transmit Clock Source, possible options are 1) loopTiming(1) 2) localTiming(2)
Status: mandatory Access: read-write
OBJECT-TYPE    
  TransClkSrc  

ss7TrunkDS1LBO 7.1.1.17
DS1 Line Build Out, possible options are 1) upTo133Feet(1) 2) upTo266Feet(2) 3) upTo399Feet(3) 4) upTo533Feet(4) 5) upTo655Feet(5) 6) negative7_5Db(6) 7) negative15Db(7) 8) negative22_5Db(8)
Status: mandatory Access: read-write
OBJECT-TYPE    
  DS1LBO  

ss7TrunkDS3LineType 7.1.1.18
DS3 Line Type possible options are 1) cbitParity(1) 2) clearChannel(2)
Status: mandatory Access: read-write
OBJECT-TYPE    
  DS3LineType  

ss7TrunkDS3TransClkSrc 7.1.1.19
DS3 Transmit Clock Source, possible options are 1) loopTiming(1) 2) localTiming(2)
Status: mandatory Access: read-write
OBJECT-TYPE    
  TransClkSrc  

ss7TrunkDS3LBO 7.1.1.20
DS3 Line Build Out possible options are 1) short(1) 2) long(2)
Status: mandatory Access: read-write
OBJECT-TYPE    
  DS3LBO  

ss7TrunkDS3DS1LineType 7.1.1.21
DS3DS1 Line Type possible options are 1) esF(1) 2) d4(2)
Status: mandatory Access: read-write
OBJECT-TYPE    
  DS1LineType  

ss7TrunkDS3DS1TransClkSrc 7.1.1.22
DS3DS1ansmit Clock Source, possible options are 1) loopTiming(1) 2) localTiming(2)
Status: mandatory Access: read-write
OBJECT-TYPE    
  TransClkSrc  

ss7TrunkOC3TransClkSrc 7.1.1.23
OC3 Transmit Clock Source, possible options are 1) loopTiming(1) 2) localTiming(2)
Status: mandatory Access: read-write
OBJECT-TYPE    
  TransClkSrc  

ss7TrunkUNCHE3TransClkSrc 7.1.1.24
UNCHANNELIZED E3 Transmit Clock Source, possible options are 1) loopTiming(1) 2) localTiming(2)
Status: mandatory Access: read-write
OBJECT-TYPE    
  TransClkSrc  

ss7TrunkDS3ATMLineType 7.1.1.25
DS3-ATM Line Type possible options are 1) cbitParity(1) 2) clearChannel(2)
Status: mandatory Access: read-write
OBJECT-TYPE    
  DS3LineType  

ss7TrunkDS3ATMCellMap 7.1.1.26
DS3-ATM Cell Mapping, possible options are 1) plcp(1) 2) directMapping(2)
Status: mandatory Access: read-write
OBJECT-TYPE    
  DS3ATMCellMap  

ss7TrunkDS3ATMTransClkSrc 7.1.1.27
DS3-ATM transmit Clock Source, possible options are 1) loopTiming(1) 2) localTiming(2)
Status: mandatory Access: read-write
OBJECT-TYPE    
  TransClkSrc  

ss7TrunkDS3ATMLBO 7.1.1.28
DS3-ATM Line Build Out possible options are 1) short(1) 2) long(2)
Status: mandatory Access: read-write
OBJECT-TYPE    
  DS3LBO  

ss7TrunkRowStatus 7.1.1.29
Current Status (configurational Status) of this SS7 Trunk. To Configure this Link, the only option is 'CREATEANDWAIT' To Delete this Link, the only option is 'DESTROY' For the 'GET' Operation, the possible options are 1) active 2) notinservice 3) no
Status: mandatory Access: read-write
OBJECT-TYPE    
  RowStatus  

ss7TrunkOpStatus 7.1.1.30
Current Status (Operational Status) of this SS7 Trunk. 'SET' Operation is NOT APPLICABLE. For the 'GET' Operation, the possible options are 1) active 2) down
Status: mandatory Access: read-only
OBJECT-TYPE    
  OpStatus  

ss7CktCfgTable 7.2
SS7 Circuit Table. The Information about SS7 Circuit(s) in MSSC are provided in this table. This table has two indices: ss7CktTrunkId and ss7CktChnlId (both Integer).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ss7CktCfgEntry

ss7CktCfgEntry 7.2.1
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ss7CktCfgEntry  

ss7CktTrunkId 7.2.1.1
User Assigned Trunk id.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7CktChnlId 7.2.1.2
User Assigned Channel id
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7CktId 7.2.1.3
Circuit id. The Id assingned to each of the circuits for a particular Trunk.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

ss7CktDpc 7.2.1.4
Destination Point Code (The Integer Value). The Point Code should be converted into its Integer equivalent. For Example: 0-1-1 is converted as 257 (for ANSI) 0-1-2 is converted as 10 (for ITU)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..16777215  

ss7CktCic 7.2.1.5
Circuit identifier code. Can be any integer from 1) 1-4095 for ITU 2) 1-16383 for ANSI
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..16383  

ss7CktDir 7.2.1.6
Traffic direction: Possible options are : 1) IN 2) OUT 3) BOTH
Status: mandatory Access: read-write
OBJECT-TYPE    
  Direction  

ss7CktPriority 7.2.1.7
Traffic priority
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7CktT3 7.2.1.8
T3 timer. Default Value is 0 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..120  

ss7CktT12 7.2.1.9
T12 timer - blocking sent. Default Value is 40 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 4000..60000  

ss7CktT13 7.2.1.10
T13 timer - initial blocking sent. Default Value is 600 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 60..900  

ss7CktT14 7.2.1.11
T14 timer - unblocking sent. Default Value is 40 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 4000..60000  

ss7CktT15 7.2.1.12
T15 timer - initial unblocking sent. Default Value is 600 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 60..900  

ss7CktT16 7.2.1.13
T16 timer - reset sent. Default Value is 40 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 4000..60000  

ss7CktT17 7.2.1.14
T17 timer - initial reset sent. Default Value is 600 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 60..900  

ss7CktTVal 7.2.1.15
TVal timer - initial reset sent. Default Value is 100 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10000  

ss7CktRowStatus 7.2.1.16
Current Status (configurational Status) of this SS7 Circuit. To Configure this circuit, the only option is 'CREATEANDWAIT'. To Delete this circuit, the only option is 'DESTROY'. To Modify any of the Circuit Timers, the only option is 'MODIFYTIMER'. Fo
Status: mandatory Access: read-write
OBJECT-TYPE    
  CktRowStatus  

ss7CktOpStatus 7.2.1.17
Current Status (Operational Status) of this SS7 Circuit. 'SET' Operation is NOT APPLICABLE. For the 'GET' Operation, the possible options are 1) active 2) down 3) block
Status: mandatory Access: read-only
OBJECT-TYPE    
  CktOpStatus  

ss7CICTimerTable 7.3
SS7 Circuit CIC Timer Table. The Information about SS7 Circuit(s) Timers in MSSC are provided in this table.User can Modify any Timer(s) in this table. This table has two indices: ss7CktTmrDpc and ss7CktTmrCic (both Integer).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ss7CicTmrEntry

ss7CicTmrEntry 7.3.1
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ss7CicTmrEntry  

ss7CktTmrDpc 7.3.1.1
Destination Point Code (The Integer Value). The Point Code should be converted into its Integer equivalent. For Example: 0-1-1 is converted as 257 (for ANSI) 0-1-2 is converted as 10 (for ITU)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..16777215  

ss7CktTmrCic 7.3.1.2
Circuit identifier code. Can be any integer 1-65535.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7CktTmrT3 7.3.1.3
T3 timer. Default Value is 0 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7CktTmrT12 7.3.1.4
T12 timer - blocking sent. Default Value is 40 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7CktTmrT13 7.3.1.5
T13 timer - initial blocking sent. Default Value is 600 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7CktTmrT14 7.3.1.6
T14 timer - unblocking sent. Default Value is 40 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7CktTmrT15 7.3.1.7
T15 timer - initial unblocking sent. Default Value is 600 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7CktTmrT16 7.3.1.8
T16 timer - reset sent. Default Value is 40 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7CktTmrT17 7.3.1.9
T17 timer - initial reset sent. Default Value is 600 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7CktTmrTVal 7.3.1.10
TVal timer - initial reset sent. Default Value is 100 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7CktTmrRowStatus 7.3.1.11
This is a command to MODIFY a Timer. A 'GET' operation on this object will display the default value [no action]. The possible option for 'SET' operation is: 1)modify
Status: mandatory Access: read-write
OBJECT-TYPE    
  ModifyTmrStatus  

ss7BCktCfgTable 7.4
SS7 B-Circuit Table. The Information about SS7 B-Circuit(s) in MSSC are provided in this table.This table has two indices: ss7BCktVpi and ss7BCktVci (both Integer).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ss7BCktCfgEntry

ss7BCktCfgEntry 7.4.1
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ss7BCktCfgEntry  

ss7BCktVpi 7.4.1.1
Broadband Virtual Path Indentifier. Can be any integer 1-65535.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7BCktVci 7.4.1.2
Broadband Virtual Channel Identifier. Can be any integer 1-65535.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7BCktTrunkId 7.4.1.3
Trunk id.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7BCktDpc 7.4.1.4
Broadband Circuit Destination Point Code (The Integer Value). The Point Code should be converted into its Integer equivalent. For Example: 0-1-1 is converted as 257 (for ANSI) 0-1-2 is converted as 10 (for ITU)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..16777215  

ss7BCktCic 7.4.1.5
Circuit identifier code. Can be any integer from : 1) 1-16383 for ANSI 2) 1-4095 for ITU
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..16383  

ss7BCktDir 7.4.1.6
Denotes Traffic direction. Possible Values are: 1) in 2) out 3) both
Status: mandatory Access: read-write
OBJECT-TYPE    
  Direction  

ss7BCktPriority 7.4.1.7
Traffic priority
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7BCktT3 7.4.1.8
T3 timer. Default Value is 0 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7BCktT12 7.4.1.9
T12 timer - blocking sent. Default Value is 40 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7BCktT13 7.4.1.10
T13 timer - initial blocking sent. Default Value is 600 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7BCktT14 7.4.1.11
T14 timer - unblocking sent. Default Value is 40 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7BCktT15 7.4.1.12
T15 timer - initial unblocking sent. Default Value is 600 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7BCktT16 7.4.1.13
T16 timer - reset sent. Default Value is 40 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7BCktT17 7.4.1.14
T17 timer - initial reset sent. Default Value is 600 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7BCktTVal 7.4.1.15
TVal timer - initial reset sent. Default Value is 100 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7BCktRowStatus 7.4.1.16
Current Status (configurational Status) of this SS7 B-Circuit. To Configure this circuit, the only option is 'CREATEANDWAIT'. To Modify any of the timers the only option is 'MODIFYTIMER' . To Delete this circuit, the only option is 'DESTROY'. For the
Status: mandatory Access: read-write
OBJECT-TYPE    
  CktRowStatus  

ss7BCktOpStatus 7.4.1.17
Current Status (Operational Status) of this SS7 B-Circuit. 'SET' Operation is NOT APPLICABLE. For the 'GET' Operation, the possible options are 1) active 2) down 3) block
Status: mandatory Access: read-only
OBJECT-TYPE    
  CktOpStatus  

ss7CktMgmntGroup 7.5
OBJECT IDENTIFIER    

ss7CktMgmntTable 7.5.1
SS7 Circuit Management Table. The Management Commands for SS7 Circuits(s) in MSSC are provided in this table. This table has two indices: ss7CktMgmntTrnkId and ss7CktMgmntChnlId (both Integer).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ss7CktMgmntEntry

ss7CktMgmntEntry 7.5.1.1
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ss7CktMgmntEntry  

ss7CktMgmntTrnkId 7.5.1.1.1
Trunk id.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ss7CktMgmntChnlId 7.5.1.1.2
Channel id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ss7CktMgmntRepNum 7.5.1.1.3
Repeat Number for this operation. This option will allow consecutive CIC to be reset
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7CktMgmntCmd 7.5.1.1.4
Management Command for Blocking/Unblocking any call setup on the specified channel. The option of repnum is provided to allow consecutive CIC to be blocked/unblocked The possible options are : 1) Block 2) UnBlock 3) Noaction [default]
Status: mandatory Access: read-write
OBJECT-TYPE    
  BlockOperation  

ss7CICMgmntTable 7.5.2
SS7 Circuit CIC Management Table. The Management Commands for SS7 Circuits(s) in MSSC are provided in this table. This table has two indices: ss7CktMgmtDPC and ss7CktMgmtCIC (both Integer).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ss7CICMgmntEntry

ss7CICMgmntEntry 7.5.2.1
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ss7CICMgmntEntry  

ss7CktMgmtDPC 7.5.2.1.1
Destination Point Code (The Integer Value). The Point Code should be converted into its Integer equivalent. For Example: 0-1-1 is converted as 257 (for ANSI) 0-1-2 is converted as 10 (for ITU)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ss7CktMgmtCIC 7.5.2.1.2
Circuit identifier code. Can be any integer from 1) 1-4095 for ITU 2) 1-16383 for ANSI
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ss7CktRepNum 7.5.2.1.3
Repeat Number for this operation. This option will allow consecutive CIC to be reset
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7CicRange 7.5.2.1.4
Range for this operation. This option will allow consecutive CIC to be reset
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7CICMgmntCmd 7.5.2.1.5
Management Command for Blocking/Unblocking any call setup on the specified channel. The option of repnum is provided to allow consecutive CIC to be blocked/unblocked The possible options are : 1) Block 2) UnBlock [default]
Status: mandatory Access: read-write
OBJECT-TYPE    
  CircuitControlStatus  

mtp2LinkTmrCfgTable 34.3.1
MTP2 Link Timer Table. The Information about MTP2 Link Timers in MSSC are provided in this table. User can Modify Timer(s) from this table. This table has one index: mtp2LinkId (Integer).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Mtp2LinkTmrCfgEntry

mtp2LinkTmrCfgEntry 34.3.1.1
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Mtp2LinkTmrCfgEntry  

mtp2LinkId 34.3.1.1.1
Link id. Can be any integer 1-65535.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

mtp2T1 34.3.1.1.2
t1 timer - for aligned ready condition GR-606-CORE, ISSUE 1, June 1994. Default Value is 13000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 13000..50000  

mtp2T2 34.3.1.1.3
t2 timer - Timer for out-of-alignment GR-606-CORE, ISSUE 1, June 1994. Default Value is 11500 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 5000..50000  

mtp2T3 34.3.1.1.4
t3 timer - Timer for aligned condition GR-606-CORE, ISSUE 1, June 1994. Default Value is 11500 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1000..15000  

mtp2T4n 34.3.1.1.5
t4n timer - Normal proving period GR-606-CORE, ISSUE 1, June 1994. Default Value is 2000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 2070..9500  

mtp2T4e 34.3.1.1.6
t4e timer - Emergency proving period GR-606-CORE, ISSUE 1, June 1994. Default Value is 500 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 400..600  

mtp2T5 34.3.1.1.7
t5 timer - Busy status transmission interval GR-606-CORE, ISSUE 1, June 1994. Default Value is 100 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 80..120  

mtp2T6 34.3.1.1.8
t6 timer - Supervision of remote congestion timer GR-606-CORE, ISSUE 1, June 1994. Default Value is 3000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 3000..6000  

mtp2T7 34.3.1.1.9
t7 timer - Excessive delay of ack GR-606-CORE, ISSUE 1, June 1994. Default Value is 500 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 500..2000  

mtp2RowStatus 34.3.1.1.10
Current Status (configurational Status) of this MTP2 Link Timer. To Modify any Timer for this link, the only option is 'MODIFYTIMER'. For the 'GET' Operation, the possible options are 1) active 2) notinservice 3) notready 4) modified 5) up 6) down
Status: mandatory Access: read-write
OBJECT-TYPE    
  TmrRowStatus  

mtp2OpStatus 34.3.1.1.11
Current Status (Operational Status) of this MTP2 Link Timer. 'SET' Operation is NOT APPLICABLE. For the 'GET' Operation, the possible options are 1) active 2) down
Status: mandatory Access: read-only
OBJECT-TYPE    
  OpStatus  

mtp3T15 34.4.1.1
T15 timer - Signal route set congestion test interval GR-606-CORE, ISSUE 1, June 1994. Default Value is 3000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 2000..3000  

mtp3T16 34.4.1.2
T16 timer - Transfer controlled update GR-606-CORE, ISSUE 1, June 1994. Default Value is 1400 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1400..2000  

mtp3T18 34.4.1.3
T18 timer - Timer for links to become available. Not Applicable to ANSI. Default Value is 1400 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

mtp3T19 34.4.1.4
T19 timer - Timer to receive all traffic restart. Not Applicable to ANSI. Default Value is 0
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 67000..69000  

mtp3T20 34.4.1.5
T20 timer - BroadCast traffic restart interval. Not Applicable to ANSI.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 59000..61000  

mtp3T21 34.4.1.6
T21 timer - Interval to restart traffic route through adjacent SP
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 63000..65000  

mtp3T26 34.4.1.7
T26 timer - Timer at restarting SP waiting to repeat TRW GR-606-CORE, ISSUE 1, June 1994. Default Value is 13500 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 12000..15000  

mtp3T30 34.4.1.8
T30 timer - Route Instance timer
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 30000..35000  

mtp3GenTmrRowStatus 34.4.1.9
This is a command to MODIFY a Timer. A 'GET' operation on this object will display the default value [no action]. The possible option for 'SET' operation is: 1)modify
Status: mandatory Access: read-write
OBJECT-TYPE    
  ModifyTmrStatus  

mtp3LinkCfgTable 34.4.2
MTP3 Link Timer Table. The Information about MTP3 Link Timers in MSSC are provided in this table. User can Modify Timer(s) from this table. This table has one index: mtp3LinkId (Integer).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Mtp3LinkCfgEntry

mtp3LinkCfgEntry 34.4.2.1
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Mtp3LinkCfgEntry  

mtp3LinkId 34.4.2.1.1
Link id GR-606-CORE, ISSUE 1, June 1994
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

mtp3T1 34.4.2.1.2
T1 timer - Transmission delay following changeover GR-606-CORE, ISSUE 1, June 1994. Default Value is 500 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 500..1200  

mtp3T2 34.4.2.1.3
T2 timer - changeover ack timer GR-606-CORE, ISSUE 1, June 1994. Default Value is 700 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 700..2000  

mtp3T3 34.4.2.1.4
T3 timer - Transmission delay following changeback GR-606-CORE, ISSUE 1, June 1994. Default Value is 500 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 500..1200  

mtp3T4 34.4.2.1.5
T4 timer - Changeback ack timer (first attempt) GR-606-CORE, ISSUE 1, June 1994. Default is 500 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 500..1200  

mtp3T5 34.4.2.1.6
T5 timer - Changeback ack timer (subsequent attempt) GR-606-CORE, ISSUE 1, June 1994. Default is 500 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 500..1200  

mtp3T6 34.4.2.1.7
T6 timer - Controlled rerouting transmission delay GR-606-CORE, ISSUE 1, June 1994. Default Value is 500 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 500..1200  

mtp3T7 34.4.2.1.8
T7 Timer - Link connection ack timer
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 500..1200  

mtp3T12 34.4.2.1.9
T12 timer - Uninhibit acknowledge timer GR-606-CORE, ISSUE 1, June 1994. Default Value is 1000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 800..1500  

mtp3T13 34.4.2.1.10
T13 timer - Forced uninhibit ack timer GR-606-CORE, ISSUE 1, June 1994. Default Value is 1000 milliSeconds.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 800..1500  

mtp3T14 34.4.2.1.11
T14 timer - Inhibit ack timer GR-606-CORE, ISSUE 1, June 1994. Default Value is 3000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 2000..3000  

mtp3T17 34.4.2.1.12
T17 timer - Timing to restart of initial alignment GR-606-CORE, ISSUE 1, June 1994. Default Value is 1000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 800..1500  

mtp3T22 34.4.2.1.13
T20 timer - Waiting to repeat local inhibit test. Default Value is 10000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 180..360  

mtp3T23 34.4.2.1.14
T21 timer - Waiting to repeat remote inhibit test. Default Value is 10000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 180..360  

mtp3T24 34.4.2.1.15
T24 timer - Stabilizing timer.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 5000..5000  

mtp3T31 34.4.2.1.16
T31 timer - Timer to detect a link in false link congestion. GR-606-CORE, ISSUE 1, June 1994. Default Value is 30000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..120  

mtp3T32 34.4.2.1.17
T32 timer - SLT timer
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 4..12  

mtp3T33 34.4.2.1.18
T33 timer - Timer to detect a link in false link congestion. GR-606-CORE, ISSUE 1, June 1994. Default Value is 30000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 60..600  

mtp3T34 34.4.2.1.19
T34 timer - Timer to detect a link in false link congestion. GR-606-CORE, ISSUE 1, June 1994. Default Value is 30000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 30..90  

mtp3T35 34.4.2.1.20
T35 timer - periodic signalling link test timer GR-606-CORE, ISSUE 1, June 1994. Default Value is 30000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..120  

mtp3T36 34.4.2.1.21
T36 timer - Probation timer for link oscillation. Not in bellcore. Default Value is 30000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 60..600  

mtp3T37 34.4.2.1.22
T37 timer - Suspension Timer for link oscillation. Not in bellcore. Default Value is 30000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 5..120  

mtp3TFLC 34.4.2.1.23
TFLC timer - Flow control request timer. Not in bellcore.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

mtp3TBND 34.4.2.1.24
TBND timer - Bind confirm wait timer. Not in bellcore.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

mtp3RowStatus 34.4.2.1.25
Current Status (configurational Status) of this MTP3 Link Timer. To Modify any Timer for this link, the only option is 'MODIFYTIMER'. For the 'GET' Operation, the possible options are 1) active 2) notinservice 3) notready 4) modified 5) up 6) down
Status: mandatory Access: read-write
OBJECT-TYPE    
  TmrRowStatus  

mtp3OpStatus 34.4.2.1.26
Current Status (Operational Status) of this MTP3 Link Timer. 'SET' Operation is NOT APPLICABLE. For the 'GET' Operation, the possible options are 1) active 2) down
Status: mandatory Access: read-only
OBJECT-TYPE    
  OpStatus  

isupTimerCfgTable 34.5.1
Isup Timer Table. The Information about ISUPTimers in MSSC are provided in this table. User can Modify Timer(s) from this table. This table has one index: isupTmrSS7Type (TimerType).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IsupTimerCfgEntry

isupTimerCfgEntry 34.5.1.1
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  IsupTimerCfgEntry  

isupTimerType 34.5.1.1.1
Index for this IsupTimer Table, is an enumerated data type ansi(1), itu(2)
Status: mandatory Access: read-write
OBJECT-TYPE    
  TimerType 1..2  

isupTmrT1 34.5.1.1.2
T1 timer - release sent, GR-246-CORE, Issue 2, December 1997. Default Value is 4000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 4000..60000  

isupTmrT2 34.5.1.1.3
T2 timer - suspend received, GR-246-CORE, Issue 2, December 1997. Default Value is 0 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..180  

isupTmrT5 34.5.1.1.4
T5 timer - initial release sent GR-246-CORE, Issue 2, December 1997. Default Value is 60000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 60..900  

isupTmrT6 34.5.1.1.5
T6 timer - suspend received GR-246-CORE, Issue 2, December 1997. Default Value is 10000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10000..32000  

isupTmrT7 34.5.1.1.6
T7 timer - latest address sent GR-246-CORE, Issue 2, December 1997. Default Value is 20000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 20000..30000  

isupTmrT8 34.5.1.1.7
T8 - timer initial address received GR-246-CORE, Issue 2, December 1997. Default Value is 10000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10000..15000  

isupTmrT9 34.5.1.1.8
T9 timer - latest address sent after ACM GR-246-CORE, Issue 2, December 1997. Default Value is 120000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 120..240  

isupTmrT18 34.5.1.1.9
T18 timer - group blocking sent GR-246-CORE, Issue 2, December 1997. Default Value is 4000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 4000..60000  

isupTmrT19 34.5.1.1.10
T19 timer - initial group blocking sent GR-246-CORE, Issue 2, December 1997. Default Value is 60000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 60..900  

isupTmrT20 34.5.1.1.11
T20 timer - group unblocking sent GR-246-CORE, Issue 2, December 1997. Default Value is 4000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 4000..60000  

isupTmrT21 34.5.1.1.12
T21 timer - initial group unblocking sent GR-246-CORE, Issue 2, December 1997. Default Value is 60000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 60..900  

isupTmrT22 34.5.1.1.13
T22 timer - group reset sent GR-246-CORE, Issue 2, December 1997. Default Value is 4000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 4000..60000  

isupTmrT23 34.5.1.1.14
T23 timer - initial group reset sent GR-246-CORE, Issue 2, December 1997. Default Value is 60000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 60..900  

isupTmrT27 34.5.1.1.15
T27 timer - waiting for continuity recheck GR-246-CORE, Issue 2, December 1997. Default Value is 200000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 18..24  

isupTmrT28 34.5.1.1.16
T28 timer - circuit group query sent GR-246-CORE, Issue 2, December 1997. Default Value is 10000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10000..10000  

isupTmrT31 34.5.1.1.17
T31 timer - call reference frozen period GR-246-CORE, Issue 2, December 1997. Default Value is 360000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 360  

isupTmrT33 34.5.1.1.18
T33 timer - INR sent GR-246-CORE, Issue 2, December 1997. Default Value is 12000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 12000..15000  

isupTmrT34 34.5.1.1.19
T34 timer - currently unknown. Default Value is 10000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10000..15000  

isupTmrT36 34.5.1.1.20
T36 timer - waiting for continuity after recheck, in bellcore it is T34 GR-246-CORE, Issue 2, December 1997. Default Value is 2000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 2000..4000  

isupTmrTCCR 34.5.1.1.21
tCCR timer - continuity recheck timer GR-246-CORE, Issue 2, December 1997. Default Value is 20000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 20000..24000  

isupTmrTEX 34.5.1.1.22
TEX timer - Exit to be sent, currently not applicable
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

isupTmrTCRM 34.5.1.1.23
TCRM timer - circuit reservation message sent. GR-246-CORE, Issue 2, December 1997. Default Value is 3000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 3000..4000  

isupTmrTCRA 34.5.1.1.24
TCRA timer - circuit reservation acknowledgement sent. GR-246-CORE, Issue 2, December 1997. Default Value is 20000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..20000  

isupTmrTCCRt 34.5.1.1.25
TCCRt timer - tCCR timer (o/g side). Default Value is 0 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2000  

isupTmrTECt 34.5.1.1.26
tECT timer - Explicit Call Transfer -wait for loop prvnt rsp. Default Value is 0 milliSeconds
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

isupTmrTGTCHG 34.5.1.1.27
Timer tGTCHG - Awaiting charging extended acknowledgement after having sent CHGE
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

isupTmrTGRES 34.5.1.1.28
TGRS timer - at receipt of circuit group reset message, treat subsequent circuit group reset messages new only on this timer expiration.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 5000..5000  

isupTmrTFGR 34.5.1.1.29
TFGR timer - first group received timer GR-246-CORE, Issue 2, December 1997
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 10000..120000  

isupTmrTRELRSP 34.5.1.1.30
Time tRELRSP - Awaiting for release response. Default Value is 0 milliSeconds
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

isupTmrTFNLRELRS 34.5.1.1.31
Time tFNLRELRSP - Awaiting for final release response. Default Value is 0 milliSeconds
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

isupTimerRowStatus 34.5.1.1.32
This is a command to MODIFY a Timer. A 'GET' operation on this object will display the default value [no action]. The possible option for 'SET' operation is: 1)modify
Status: mandatory Access: read-write
OBJECT-TYPE    
  ModifyTmrStatus  

ss7RtDpcTable 34.6.1
SS7 Route Dpc Table. The Information about Route(s) in MSSC are provided in this table. This table has one index: ss7RtDPC (Integer).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ss7RtDpcEntry

ss7RtDpcEntry 34.6.1.1
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ss7RtDpcEntry  

ss7RtDPC 34.6.1.1.1
The Route Destination Point Code (The Integer Value). The Point Code should be converted into its Integer equivalent. For Example: 0-1-1 is converted as 257 (for ANSI) 0-1-2 is converted as 10 (for ITU)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..16777215  

ss7RtCmbLinksetId 34.6.1.1.2
SS7 Linkset Id which is already configured so far. An incorrect Linkset Id will result a failure at the time of 'CREATION' of the Route table for the specified DPC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

ss7RtLoadShareType 34.6.1.1.3
Load Share type(ANSI/ITU)
Status: mandatory Access: read-write
OBJECT-TYPE    
  Standard  

ss7RtRowStatus 34.6.1.1.4
Current Status (configurational Status) of this SS7 Route. To Configure this Route, the only option is 'CREATEANDWAIT'. To Delete this Route, the only option is 'DESTROY'. For the 'GET' Operation, the possible options are 1) active 2) notinservice 3
Status: mandatory Access: read-write
OBJECT-TYPE    
  RowStatus  

ss7RtOpStatus 34.6.1.1.5
Current Status (Operational Status) of this SS7 Route. 'SET' Operation is NOT APPLICABLE. For the 'GET' Operation, the possible options are 1) active 2) down
Status: mandatory Access: read-only
OBJECT-TYPE    
  OpStatus  

isdnTmrCfgTable 17.1
ISDN Timer Table. The Information about ISDN Timers in MSSC are provided in this table. User can Modify Timer(s) from this table. This table has one index: isdnTnkId (Integer).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IsdnTmrCfgEntry

isdnTmrCfgEntry 17.1.1
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  IsdnTmrCfgEntry  

isdnTnkId 17.1.1.1
Trunk id.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

isdnTmrT301 17.1.1.2
T301 timer - alert received Recommandation Q.931, TABLE 9-1/Q931
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 180..420  

isdnTmrT302 17.1.1.3
T302 timer - SETUP ACK sent Receipt of INFO Recommandation Q.931, TABLE 9-1/Q931
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15000  

isdnTmrT303 17.1.1.4
T303 timer - setup sent Recommandation Q.931, TABLE 9-1/Q931. Default Value is 4000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1000..4000  

isdnTmrT304 17.1.1.5
T304 timer - setup ack received info sent alert Recommandation Q.931, TABLE 9-1/Q931. Default Value is 20000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..20000  

isdnTmrT305 17.1.1.6
T305 timer - disc w/ prog ind sent or disc sent Recommandation Q.931, TABLE 9-1/Q931. Default Value is 30000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 2000..60000  

isdnTmrT306 17.1.1.7
T306 timer - disc without prog ind sent Recommandation Q.931, TABLE 9-1/Q931. Default Value is 30000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 30..150  

isdnTmrT307 17.1.1.8
T307 timer - iusp ack sent Recommandation Q.931, TABLE 9-1/Q931. Default Value is 180000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..180  

isdnTmrT308 17.1.1.9
T308 timer - release sent Recommandation Q.931, TABLE 9-1/Q931. Default Value is 4000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 2000..10000  

isdnTmrT310 17.1.1.10
T310 timer - call proc received Recommandation Q.931, TABLE 9-1/Q931. Default Value is 10000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 3000..10000  

isdnTmrT311 17.1.1.11
T310 timer - call proc received, not in the network side
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

isdnTmrT312 17.1.1.12
T312 timer - setup sent on broadcast Recommandation Q.931, TABLE 9-1/Q931. Default Value is 6000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..6000  

isdnTmrT313 17.1.1.13
T313 timer - conn sent, not in BellCore network side
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

isdnTmrT316 17.1.1.14
T316 timer - restart sent interface Recommandation Q.931, TABLE 9-1/Q931. Default Value is 120000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..120  

isdnTmrT318 17.1.1.15
T318 timer - resume sent, not in bellcore network side
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

isdnTmrT319 17.1.1.16
T319 timer - suspend sent, not in Bellcore network side
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

isdnTmrT322 17.1.1.17
T322 timer - stat enq sent Recommandation Q.931, TABLE 9-1/Q931. Default Value is 4000 milliSeconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 2000..10000  

isdnTmrT316C 17.1.1.18
T316c Timer -Restart sent to individual channel
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 30..120  

isdnTmrT330 17.1.1.19
T330 Timer - Congestion with Upper
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

isdnTmrT331 17.1.1.20
T331 Timer - Congestion with lower
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

isdnTmrT332 17.1.1.21
T332 Timer - Service request sent
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

isdnTmrTRST 17.1.1.22
TRst Timer - Disconnect indication sent while restarting interface
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 30..600  

isdnTmrTREST 17.1.1.23
TREST Timer - Disconnect indication sent while NI2 restarting interface
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 30..600  

isdnTmrTANS 17.1.1.24
TAns Timer - Answer timer
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65553  

isdnTmrT396 17.1.1.25
T396 Timer - t303 expired
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

isdnTmrT397 17.1.1.26
T397 Timer - Information sent on permanent signal
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

isdnTrnkTmrRowStatus 17.1.1.27
Current Status (configurational Status) of this Isdn Trunk Timer. To Modify any Timer for this Trunk, the only option is 'MODIFYTIMER'. For the 'GET' Operation, the possible options are 1) active 2) notinservice 3) notready 4) modified 5) up 6) do
Status: mandatory Access: read-write
OBJECT-TYPE    
  TmrRowStatus  

isdnTrnkTmrOpStatus 17.1.1.28
Current Status (Operational Status) of this Isdn Timer. 'SET' Operation is NOT APPLICABLE. For the 'GET' Operation, the possible options are 1) active 2) down
Status: mandatory Access: read-only
OBJECT-TYPE    
  OpStatus  

isdnTrunkCfgTable 17.2
ISDN Trunk Table. Information about the ISDN Trunk(s) in MSSC are provided in this table. The index of this table is isdnTrunkId (Integer)
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IsdnTrunkCfgEntry

isdnTrunkCfgEntry 17.2.1
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  IsdnTrunkCfgEntry  

isdnTrunkId 17.2.1.1
Trunk id. Can be any integer 1-65535.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

isdnTrunkName 17.2.1.2
Trunk name. Can be any combinaton of alphanumeric characters. Spaces are not allowed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  NameString  

isdnTrunkGrpId 17.2.1.3
Trunk Group id to which the trunk belongs. Can be any integer 1-65535.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

isdnDchnlId 17.2.1.4
D-Channel Id
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

isdnTrunkType 17.2.1.5
Trunk Type (nfas/fas).
Status: mandatory Access: read-write
OBJECT-TYPE    
  IsdnType  

isdnXconnectId 17.2.1.6
Xconnect id
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

isdnSlotId 17.2.1.7
Slot id
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

isdnPortId 17.2.1.8
Port id
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

isdnDirection 17.2.1.9
Traffic direction. possible options are 1) in 2) out 3) both
Status: mandatory Access: read-write
OBJECT-TYPE    
  Direction  

isdnPriority 17.2.1.10
Traffic priority
Status: mandatory Access: read-write
OBJECT-TYPE    
  IsdnPriority  

isdnDurthreshold 17.2.1.11
Bad Call Duration Threshold
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

isdnCntthreshold 17.2.1.12
Bad Call Count Threshold
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

isdnPhyIntfType 17.2.1.13
Isdn Physical Interface Type possible options are 1) T1 (interface-t1) 2) T3 (interface-t3) 3) Unchannelized T3 (interface-ut3) 4) OC3 (interface-oc3) 5) Unchannelized T3 with compression (interface-ut3cp) 6) OC3 with compression (interface-oc3cp)
Status: mandatory Access: read-write
OBJECT-TYPE    
  IfType  

isdnDchnlTimeSlot 17.2.1.14
D-Channel Time slot
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

isdnE1MultiFrame 17.2.1.15
E1 multiFrame Type possible options are 1) CAS(1) 2) CCS(2)
Status: mandatory Access: read-write
OBJECT-TYPE    
  E1MultiFrame  

isdnE1CRC4 17.2.1.16
E1 Cyclic Redundancy Code, possible options are 1) enabled(1) 2) disable(2)
Status: mandatory Access: read-write
OBJECT-TYPE    
  E1CRC4  

isdnE1TransClk 17.2.1.17
E1 Transmit Clock Source, possible options are 1) loopTiming(1) 2) localTiming(2)
Status: mandatory Access: read-write
OBJECT-TYPE    
  TransClkSrc  

isdnDS1LineType 17.2.1.18
DS1 Line Type possible options are 1) esF(1) 2) d4(2)
Status: mandatory Access: read-write
OBJECT-TYPE    
  DS1LineType  

isdnDS1LineCoding 17.2.1.19
DS1 Line Coding, possible options are 1) b8zs(1) 2) ami(2)
Status: mandatory Access: read-write
OBJECT-TYPE    
  DS1LineCoding  

isdnDS1TransClkSrc 17.2.1.20
DS1 Transmit Clock Source, possible options are 1) loopTiming(1) 2) localTiming(2)
Status: mandatory Access: read-write
OBJECT-TYPE    
  TransClkSrc  

isdnDS1LBO 17.2.1.21
DS1 Line Build Out, possible options are 1) upTo133Feet(1) 2) upTo266Feet(2) 3) upTo399Feet(3) 4) upTo533Feet(4) 5) upTo655Feet(5) 6) negative7_5Db(6) 7) negative15Db(7) 8) negative22_5Db(8)
Status: mandatory Access: read-write
OBJECT-TYPE    
  DS1LBO  

isdnDS3LineType 17.2.1.22
DS3 Line Type possible options are 1) cbitParity(1) 2) clearChannel(2)
Status: mandatory Access: read-write
OBJECT-TYPE    
  DS3LineType  

isdnDS3TransClkSrc 17.2.1.23
DS3 Transmit Clock Source, possible options are 1) loopTiming(1) 2) localTiming(2)
Status: mandatory Access: read-write
OBJECT-TYPE    
  TransClkSrc  

isdnDS3LBO 17.2.1.24
DS3 Line Build Out possible options are 1) short(1) 2) long(2)
Status: mandatory Access: read-write
OBJECT-TYPE    
  DS3LBO  

isdnDS3DS1LineType 17.2.1.25
DS3DS1 Line Type possible options are 1) esF(1) 2) d4(2)
Status: mandatory Access: read-write
OBJECT-TYPE    
  DS1LineType  

isdnDS3DS1TransClkSrc 17.2.1.26
DS3DS1 Transmit Clock Source, possible options are 1) loopTiming(1) 2) localTiming(2)
Status: mandatory Access: read-write
OBJECT-TYPE    
  TransClkSrc  

isdnTrunkRowStatus 17.2.1.27
Current Status (configurational Status) of this ISDN TRUNK. To Configure this Link, the only option is 'CREATEANDWAIT' To Delete this Link, the only option is 'DESTROY' For the 'GET' Operation, the possible options are 1) active 2) notinservice 3) n
Status: mandatory Access: read-write
OBJECT-TYPE    
  RowStatus  

isdnTrunkOpStatus 17.2.1.28
Current Status (Operational Status) of this ISDN Trunk. 'SET' Operation is NOT APPLICABLE. For the 'GET' Operation, the possible options are 1) active 2) down 3) disable
Status: mandatory Access: read-only
OBJECT-TYPE    
  IsdnTrnkOpStatus  

isdnChnlStatusTable 17.3
ISDN Channel Status Table. Information about the DS0 Channel(s) Status in MSSC are provided in this table. The index of this table is isdnStatusTrunkId (Integer)
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IsdnChnlStatusCfgEntry

isdnChnlStatusCfgEntry 17.3.1
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  IsdnChnlStatusCfgEntry  

isdnStatusTrunkId 17.3.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

isdnStatusChnlId 17.3.1.2
Channel id.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

isdnStatusChnlState 17.3.1.3
Isdn Channel String.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TrunkState  

isdnStatusChnlAllocMeth 17.3.1.4
Isdn Channel AllocMeth.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

isdnStatusChnlSuConnId 17.3.1.5
Isdn Channel SuConnId.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

isdnMgmntGroup 17.4
OBJECT IDENTIFIER    

isdnTrnkMgmntTable 17.4.1
ISDN Trunk Management Table. The Management Commands for ISDN Trunk(s) in MSSC are provided in this table. This table has the index isdnTrnkMgmntId (Integer).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IsdnTrnkMgmntEntry

isdnTrnkMgmntEntry 17.4.1.1
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  IsdnTrnkMgmntEntry  

isdnTrnkMgmntId 17.4.1.1.1
Trunk id.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

isdnTrnkMgmntCmd 17.4.1.1.2
Management Command for Enabling/Disabling the specified trunk group. This command will make all the channels in this trunk available The possible options are : 1) Enable 2) Disable [default]
Status: mandatory Access: read-write
OBJECT-TYPE    
  IsdnTrnkMgtOperation  

isdnChnlMgmntTable 17.4.2
ISDN Trunk Channel Management Table. The Management Commands for ISDN Trunk(s) in MSSC are provided in this table. This table has the index isdnTrunkMgmntId (Integer).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IsdnChnlMgmntEntry

isdnChnlMgmntEntry 17.4.2.1
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  IsdnChnlMgmntEntry  

isdnTrunkMgmntId 17.4.2.1.1
Trunk id.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

isdnChnlMgmntId 17.4.2.1.2
Channel id.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

isdnChnlMgmntCmd 17.4.2.1.3
Management Command for Enabling/Disabling the specified Channel in the specified trunk. The possible options are : 1) Enable 2) Disable [default]
Status: mandatory Access: read-write
OBJECT-TYPE    
  IsdnChnlMgtOperation  

mfdMgmntTable 17.4.3
Modem Fault Management Table. The Management Commands for Modem(s) in MSSC are provided in this table. This table has the index isdnTnkMgmntId (Integer).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MfdMgmntEntry

mfdMgmntEntry 17.4.3.1
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MfdMgmntEntry  

isdnTnkMgmntId 17.4.3.1.1
Isdn Trunk id.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

isdnDurThreshold 17.4.3.1.2
Bad Call Duration Threshold. A value 0 means disable. If mfd is enabled the normal value for this field would be 3
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

isdnCntThreshold 17.4.3.1.3
Bad Call Count Threshold A value 0 means disable. If mfd is enabled the normal value for this field would be 3
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

mfdMgmntCmd 17.4.3.1.4
Management Command for Enabling/Disabling 'MODEM FAULT DETECTION' feature in MSSC. The possible options are : 1) Enable 2) Disable [default]
Status: mandatory Access: read-write
OBJECT-TYPE    
  EnableOperation  

routeTable 1.3.6.1.4.1.4618.1.2.2.4.1
Route Table. Information about the Route(s) in MSSC are provided in this table. The index of this table is routeId (Integer)
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RouteEntry

routeEntry 1.3.6.1.4.1.4618.1.2.2.4.1.1
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  RouteEntry  

routeId 1.3.6.1.4.1.4618.1.2.2.4.1.1.1
Route Group id. Can be any integer 1-65535.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

routeAddrType 1.3.6.1.4.1.4618.1.2.2.4.1.1.2
Call Control routing type The possible option are: 1) Call party number 2) Transit Network Selection
Status: mandatory Access: read-write
OBJECT-TYPE    
  AddrType  

routeAdrId 1.3.6.1.4.1.4618.1.2.2.4.1.1.3
Call Control route request nature of address. The possible options are: 1) National number 2) International number 3) Unknown
Status: mandatory Access: read-write
OBJECT-TYPE    
  AddrIdentifier  

routeAddr 1.3.6.1.4.1.4618.1.2.2.4.1.1.4
Call Control routing number
Status: mandatory Access: read-write
OBJECT-TYPE    
  AddrString  

routeNumPlan 1.3.6.1.4.1.4618.1.2.2.4.1.1.5
Call control route request numbering plan. The possible options are: 1) Number not present(nonumber) 2) ISDN numbering Plan(isdnnumplan) 3) Telephony numbering plan(telephonynumplan) 4) Private Numbering Plan(privatenumplan)
Status: mandatory Access: read-write
OBJECT-TYPE    
  NumPlan  

routeNumOfDigit 1.3.6.1.4.1.4618.1.2.2.4.1.1.6
Number of Digit in the route.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

routeRouteName 1.3.6.1.4.1.4618.1.2.2.4.1.1.7
Route Name. Can be any combination of alphanumeric characters. Spaces are not allowed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  NameString  

routeRouteType 1.3.6.1.4.1.4618.1.2.2.4.1.1.8
Route type: SS7/ISDN
Status: mandatory Access: read-write
OBJECT-TYPE    
  RouteType  

routeRowStatus 1.3.6.1.4.1.4618.1.2.2.4.1.1.9
Current Status (configurational Status) of this ROUTE. To Configure this Route, the only option is 'CREATEANDWAIT' To Delete this Route, the only option is 'DESTROY' For the 'GET' Operation, the possible options are 1) active 2) notinservice 3) notr
Status: mandatory Access: read-write
OBJECT-TYPE    
  RowStatus  

routeOpStatus 1.3.6.1.4.1.4618.1.2.2.4.1.1.10
Current Status (Operational Status) of this Route. 'SET' Operation is NOT APPLICABLE. For the 'GET' Operation, the possible options are 1) active 2) down
Status: mandatory Access: read-only
OBJECT-TYPE    
  OpStatus  

rtEntryIsdnCfgTable 1.3.6.1.4.1.4618.1.2.2.4.2
RtEntry Isdn Table. Information about the RtEntry(s) in MSSC are provided in this table.The Table has two indices: rtEntryIsdnGrpId and rtEntryIsdntrunkId (both Integer).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RtEntryIsdnCfgEntry

rtEntryIsdnCfgEntry 1.3.6.1.4.1.4618.1.2.2.4.2.1
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  RtEntryIsdnCfgEntry  

rtEntryIsdnGrpId 1.3.6.1.4.1.4618.1.2.2.4.2.1.1
Route ISDN group id. Can be any integer 1-65535.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

rtEntryIsdntrunkId 1.3.6.1.4.1.4618.1.2.2.4.2.1.2
Route ISDN Trunk id. Can be any integer 1-256.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..256  

rtEntryIsdnRouteName 1.3.6.1.4.1.4618.1.2.2.4.2.1.3
Route ISDN group name. Can be any combination of alphanumeric characters. Spaces are not allowed and cannot exceed 15 characters.
Status: mandatory Access: read-write
OBJECT-TYPE    
  NameString  

rtEntryIsdnRowStatus 1.3.6.1.4.1.4618.1.2.2.4.2.1.4
Current Status (configurational Status) of this ISDN ROUTE Entry. To Configure this Link, the only option is 'CREATEANDWAIT' To Delete this Link, the only option is 'DESTROY' For the 'GET' Operation, the possible options are 1) active 2) notinservice
Status: mandatory Access: read-write
OBJECT-TYPE    
  RowStatus  

rtEntryIsdnOpStatus 1.3.6.1.4.1.4618.1.2.2.4.2.1.5
Current Status (Operational Status) of this ISDN Route. 'SET' Operation is NOT APPLICABLE. For the 'GET' Operation, the possible options are 1) active 2) down
Status: mandatory Access: read-only
OBJECT-TYPE    
  OpStatus  

rtEntrySs7CfgTable 1.3.6.1.4.1.4618.1.2.2.4.3
RtEntry SS7 Table. Information about the RtEntry(s) in MSSC are provided in this table.The Table has two indices: rtEntrySs7GrpId and rtEntrySs7CmbLinksetId (both Integer).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RtEntrySs7CfgEntry

rtEntrySs7CfgEntry 1.3.6.1.4.1.4618.1.2.2.4.3.1
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  RtEntrySs7CfgEntry  

rtEntrySs7GrpId 1.3.6.1.4.1.4618.1.2.2.4.3.1.1
Route SS7 group id. Can be any integer 1-65535.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

rtEntrySs7CmbLinksetId 1.3.6.1.4.1.4618.1.2.2.4.3.1.2
SS7 Linkset Id which is already configured so far. An incorrect Linkset Id will result a failure at the time of 'CREATION' of the RtEntry ie, addition of the Destination Point Code into the specified Route will fail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

rtEntrySs7RouteName 1.3.6.1.4.1.4618.1.2.2.4.3.1.3
Route SS7 group name. Can be any combination of alphanumeric characters Spaces are not allowed and cannot exceed 15 characters.
Status: mandatory Access: read-write
OBJECT-TYPE    
  NameString  

rtEntrySs7Dpc 1.3.6.1.4.1.4618.1.2.2.4.3.1.4
Route SS7 Destination Point Code (The Integer Value). The Point Code should be converted into its Integer equivalent. For Example: 0-1-1 is converted as 257 (for ANSI) 0-1-2 is converted as 10 (for ITU)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..16777215  

rtEntrySs7Mode 1.3.6.1.4.1.4618.1.2.2.4.3.1.5
Route SS7 Type(ANSI/ITU)
Status: mandatory Access: read-write
OBJECT-TYPE    
  Standard  

rtEntrySs7RowStatus 1.3.6.1.4.1.4618.1.2.2.4.3.1.6
Current Status (configurational Status) of this SS7 Route Entry. To Configure this Link, the only option is 'CREATEANDWAIT' To Delete this Link, the only option is 'DESTROY' For the 'GET' Operation, the possible options are 1) active 2) notinservice
Status: mandatory Access: read-write
OBJECT-TYPE    
  RowStatus  

rtEntrySs7OpStatus 1.3.6.1.4.1.4618.1.2.2.4.3.1.7
Current Status (Operational Status) of this SS7 Route. 'SET' Operation is NOT APPLICABLE. For the 'GET' Operation, the possible options are 1) active 2) down
Status: mandatory Access: read-only
OBJECT-TYPE    
  OpStatus  

routeMgmntCmdGroup 1.3.6.1.4.1.4618.1.2.2.4.4
OBJECT IDENTIFIER    

digitStripMgmntTable 1.3.6.1.4.1.4618.1.2.2.4.4.1
Route Management Command Table. Commands for enabling or disabling digit stripping in MSSC's routing feature are applied here. The index for this table is rtName(String).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DigitStripMgmntEntry

digitStripMgmntEntry 1.3.6.1.4.1.4618.1.2.2.4.4.1.1
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DigitStripMgmntEntry  

rtName 1.3.6.1.4.1.4618.1.2.2.4.4.1.1.1
Route Name. Can be any combination of alphanumeric characters. Spaces are not allowed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  NameString  

rtAddrType 1.3.6.1.4.1.4618.1.2.2.4.4.1.1.2
Call Control route request nature of address. The possible options are: 1) National number 2) International number 3) Unknown
Status: mandatory Access: read-write
OBJECT-TYPE    
  AddrIdentifier  

rtNumOfDigit 1.3.6.1.4.1.4618.1.2.2.4.4.1.1.3
Number of Digit in the route.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

rtMgmntCmd 1.3.6.1.4.1.4618.1.2.2.4.4.1.1.4
Management Command for Enabling/Disabling Digit Strip for MSSC's Routing Feature. The possible options are : 1) Enable 2) Disable [default]
Status: mandatory Access: read-write
OBJECT-TYPE    
  EnableOperation  

isdnLoadBalanceMgmntTable 1.3.6.1.4.1.4618.1.2.2.4.4.2
Isdn Channel Load Balance Command Table. Turning this feature on will result in distributing all the incoming calls evenly in all the trunks for the specified route number. The index for this table is rteName(String).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IsdnLoadBalanceMgmntEntry

isdnLoadBalanceMgmntEntry 1.3.6.1.4.1.4618.1.2.2.4.4.2.1
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  IsdnLoadBalanceMgmntEntry  

rteName 1.3.6.1.4.1.4618.1.2.2.4.4.2.1.1
Route Name. Can be any combination of alphanumeric characters. Spaces are not allowed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  NameString  

ilbMgmntCmd 1.3.6.1.4.1.4618.1.2.2.4.4.2.1.2
Management Command for Enabling/Disabling the feature 'ISDN Channel LOAD BALANCE'. When this feature is turned on all the incoming calls are distributed evenly in all the trunks for the specified routing numbers. The possible options are : 1) Enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  EnableOperation  

enableSwitch 1.3.6.1.4.1.4618.1.2.2.6.1
This is POST-CONFIGURATION command to ENABLE the switch. The 'GET' operation will result in the default value (no) being returned. The possible options are: 1) yes 2) no (Default)
Status: mandatory Access: read-write
OBJECT-TYPE    
  EnableStatus  

enableSS7Route 1.3.6.1.4.1.4618.1.2.2.6.2
This is POST-CONFIGURATION command to ENABLE the SS7 Route. The 'GET' operation will result in the default value (no) being returned. The possible options are: 1) yes 2) no (Default)
Status: mandatory Access: read-write
OBJECT-TYPE    
  EnableStatus  

enableSS7Ckt 1.3.6.1.4.1.4618.1.2.2.6.3
This is POST-CONFIGURATION command to ENABLE the SS7 Circuit. This Command can only be applied to Enable the SS7 Circuit and COMMIT all the SS7 Circuit Configuration. The 'GET' operation will result in the default value (no) being returned. The possib
Status: mandatory Access: read-write
OBJECT-TYPE    
  EnableStatus  

enableIsdntrunk 1.3.6.1.4.1.4618.1.2.2.6.4
This is POST-CONFIGURATION command to ENABLE the ISDN Trunk. This Command can only be applied to Enable the ISDN Trunk. The 'GET' operation will result in the default value (no) being returned. The possible options are: 1) yes 2) no (Default)
Status: mandatory Access: read-write
OBJECT-TYPE    
  EnableStatus  

enableXconnect 1.3.6.1.4.1.4618.1.2.2.6.5
This is POST-CONFIGURATION command to ENABLE the Xconnect. The 'GET' operation will result in the default value (no) being returned. The possible options are: 1) yes 2) no (Default)
Status: mandatory Access: read-write
OBJECT-TYPE    
  EnableStatus  

enableRoute 1.3.6.1.4.1.4618.1.2.2.6.6
This is POST-CONFIGURATION command to ENABLE the ROUTE and COMMIT all the configuration set for MTP2. This Command can only be applied to Enable the XConnect. The 'GET' operation will result in the default value (no) being returned. The possible optio
Status: mandatory Access: read-write
OBJECT-TYPE    
  EnableStatus  

measFileInfo 1.3.6.1.4.1.4618.1.2.3.1.1
OBJECT IDENTIFIER    

measFileConfig 1.3.6.1.4.1.4618.1.2.3.1.2
OBJECT IDENTIFIER    

measFileEnableGrp 1.3.6.1.4.1.4618.1.2.3.1.3
OBJECT IDENTIFIER    

measFileAcknowledge 1.3.6.1.4.1.4618.1.2.3.1.1.1
Acknowledgement of the receiving of the specified Measurement file
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..255)  

measFileCfgMeasInterval 1.3.6.1.4.1.4618.1.2.3.1.2.1
Switch Config Measure Interval. The duration of the collection window (frequency of persisting collected measurements). Default: 15 minutes. Valid Values: 15, 30, 60 minutes. 0 for Disable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..60  

measFileCfgUsagescanInterval 1.3.6.1.4.1.4618.1.2.3.1.2.2
Switch Config Usage Scan Interval. The interval between scanning the trunk for usage counts. Default: 15 seconds Valid Values: 5 through 300 seconds.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 5..300  

measFileCfgPurgeDay 1.3.6.1.4.1.4618.1.2.3.1.2.3
File Config Purge Day. After The specified no of days the file in secondary directory are purged if Measurement File Auto Purge Flag is on.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..30  

measFileCfgPurgeFlag 1.3.6.1.4.1.4618.1.2.3.1.2.4
File Config Flag. This is an auto purge flag.
Status: mandatory Access: read-write
OBJECT-TYPE    
  MeasPurgeFlag  

measFileCfgPrimaryDir 1.3.6.1.4.1.4618.1.2.3.1.2.5
Measurement File Primary Dir. Measurement file is written in this directory
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

measFileCfgSecondaryDir 1.3.6.1.4.1.4618.1.2.3.1.2.6
Measurement File Secondary Dir. Measurement file is moved to this directory from Primary Directory after receving the acknowledgement.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

measFileEnablePRITraffic 1.3.6.1.4.1.4618.1.2.3.1.3.1
Measurement File PRI Traffic Enable Group. A mechanism for the user to enable collecting of PRI Traffic measurement data.
Status: mandatory Access: read-write
OBJECT-TYPE    
  MeasEnableStatus  

measFileEnableISUPTraffic 1.3.6.1.4.1.4618.1.2.3.1.3.2
Measurement File ISUP Traffic Enable Group. A mechanism for the user to enable collecting of ISUP Traffic measurement data.
Status: mandatory Access: read-write
OBJECT-TYPE    
  MeasEnableStatus  

measFileEnablePRIIneffectiveCall 1.3.6.1.4.1.4618.1.2.3.1.3.3
Measurement File Enable PRI Ineffective Call Group. A mechanism for the user to enable collecting of PRI Ineffective Call Group measurement data.
Status: mandatory Access: read-write
OBJECT-TYPE    
  MeasEnableStatus  

measFileEnableISUPIneffectiveCall 1.3.6.1.4.1.4618.1.2.3.1.3.4
Measurement File Enable PRI Ineffective Call Group. A mechanism for the user to enable collecting of ISUP Ineffective Call Group Traffic measurement data.
Status: mandatory Access: read-write
OBJECT-TYPE    
  MeasEnableStatus  

measFileEnableTrunkGrp 1.3.6.1.4.1.4618.1.2.3.1.3.5
Measurement File Enable Trunk Group. A mechanism for the user to enable collecting of Trunk Group Traffic measurement data.
Status: mandatory Access: read-write
OBJECT-TYPE    
  MeasEnableStatus  

measFileEnableSS7LinkTraffic 1.3.6.1.4.1.4618.1.2.3.1.3.6
Measurement File Enable SS7 Link Traffic Group. A mechanism for the user to enable collecting of SS7 Link Traffic measurement data.
Status: mandatory Access: read-write
OBJECT-TYPE    
  MeasEnableStatus  

measSwitchIsupGrp 1.3.6.1.4.1.4618.1.2.3.2.1
OBJECT IDENTIFIER    

measSwitchIsupFailCallGrp 1.3.6.1.4.1.4618.1.2.3.2.2
OBJECT IDENTIFIER    

measSwitchPriGrp 1.3.6.1.4.1.4618.1.2.3.2.3
OBJECT IDENTIFIER    

measSwitchPriFailCallGrp 1.3.6.1.4.1.4618.1.2.3.2.4
OBJECT IDENTIFIER    

measTrnkGrpTrafficTable 1.3.6.1.4.1.4618.1.2.3.3.1
Switch Measurement for Trunk Group traffic Table. Information about Trunk Group traffic measurement are provoded in this table. The index for this table is measTrnkGrpName(String).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MeasTrnkGrpTrafficEntry

measTrnkGrpTrafficEntry 1.3.6.1.4.1.4618.1.2.3.3.1.1
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MeasTrnkGrpTrafficEntry  

measTrnkGrpName 1.3.6.1.4.1.4618.1.2.3.3.1.1.1
Trunk Group Name. Can be any combination of alphanumeric characters. Spaces are not allowed and cannot exceed 15 characters.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

measTrnkGrpDataSuspect 1.3.6.1.4.1.4618.1.2.3.3.1.1.2
Trunk Group Data Suspect. Boolean value indicating if the measurement data set is suspect. Suspect data is that which may or may not be accurate and cannot be verified accurate due to some condition that occurred during the collection interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

measTrnkGrpincomingUsage 1.3.6.1.4.1.4618.1.2.3.3.1.1.3
Trunk Group Incoming Usage. The sum of the counts of the number of incoming trunks in the use.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

measTrnkGrpoutgoingUsage 1.3.6.1.4.1.4618.1.2.3.3.1.1.4
Trunk Group Outgoing Usage. The sum of the counts of the number of outgoing trunks in the use.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

measTrnkGrpISCicsChnls 1.3.6.1.4.1.4618.1.2.3.3.1.1.5
Trunk Group Inservice Cic/Channels. The sum of the counts of the number of Inservice circuits in case SS7 TrunkGroup or Inservice Channels in case of ISDN TRunkGroup.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

measTrnkGrpOOSCicsChnls 1.3.6.1.4.1.4618.1.2.3.3.1.1.6
Trunk Group OutOfservice Cic/Channels. The sum of the counts of the number of OutOfservice circuits in case SS7 TrunkGroup or OufOfservice Channels in case of ISDN TRunkGroup.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

measTrnkGrptotalUsage 1.3.6.1.4.1.4618.1.2.3.3.1.1.7
Trunk Group Total Usage. The sum of number of trunk in use by both incoming and outgoing traffic.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

measTrnkGrpmaintainanceUsage 1.3.6.1.4.1.4618.1.2.3.3.1.1.8
Trunk Group Maintenance Usage. The sum of number of trunk in use for any reason other than traffic.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

measLinkTrafficTable 1.3.6.1.4.1.4618.1.2.3.4.1
Switch Measurement per SS7 Link traffic Table. Information about traffic measurement per SS7 Link are provoded in this table. The index for this table is measLinkName(String).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MeasLinkTrafficEntry

measLinkTrafficEntry 1.3.6.1.4.1.4618.1.2.3.4.1.1
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MeasLinkTrafficEntry  

measLinkName 1.3.6.1.4.1.4618.1.2.3.4.1.1.1
SS7 Link name
Status: mandatory Access: read-only
OBJECT-TYPE    
  NameString  

measLinkDataSuspect 1.3.6.1.4.1.4618.1.2.3.4.1.1.2
Link Data Suspect. Boolean value indicating if the measurement data set is suspect. Suspect data is that which may or may not be accurate and cannot be verified accurate due to some condition that occurred during the collection interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

measLinkUnavailableDuration 1.3.6.1.4.1.4618.1.2.3.4.1.1.3
Link Unavailable Duration. The cumulative time (in sconds) that the link was unavailable during the associated time interval (CS)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

measLinkInServiceDuration 1.3.6.1.4.1.4618.1.2.3.4.1.1.4
Link In Service Duration. The cumulative time (in seconds) during which the link was in the in-service state. A link is said to be in- service when it is capable of transmitting MSUs. This measurement includes periods when no MSUs are available for tra
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

measLinkMSUsRetransmitted 1.3.6.1.4.1.4618.1.2.3.4.1.1.5
Link MSUs Retransmitted. The number of MSUs retransmitted via a particular link during the associated time period (CS)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

measLinkOctetsReceived 1.3.6.1.4.1.4618.1.2.3.4.1.1.6
Link Octers Received. The number of SIF and SIO octets received on the associate incoming link (CS)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

measLinkOctectsTransmitted 1.3.6.1.4.1.4618.1.2.3.4.1.1.7
Link Octets Transmitted. The number of SIF and SIO octets transmitted (including those retransmitted) on the associated incoming link (CS)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

measLinkLostMSUsBufferOverflow 1.3.6.1.4.1.4618.1.2.3.4.1.1.8
Link Lost MSUs Buffer Overflow. The number of MSUs lost because of transmission buffer overflow (CS)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

measLinkMSUsDiscarded 1.3.6.1.4.1.4618.1.2.3.4.1.1.9
Link MSUs Discarded. This measurement is a count of number of MSUs discarded.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

measSwitchIsupDataSuspect 1.3.6.1.4.1.4618.1.2.3.2.1.1
Switch Isup Data Suspect. Boolean value indicating if the measurement data set is suspect. Suspect data is that which may or may not be accurate and cannot be verified accurate due to a some condition that occurred during the collection interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

measSwitchIsupIncomingAnsiTrunkCallAttempts 1.3.6.1.4.1.4618.1.2.3.2.1.2
Switch Isup Incoming Ansi Trunk Call Attempts. The number of incoming ISUP-ANSI trunk call requests.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

measSwitchIsupIncomingAnsiTrunkCallAnswered 1.3.6.1.4.1.4618.1.2.3.2.1.3
Switch Isup Incoming Ansi Trunk Call Answered. The number of incoming ISUP-ANSI trunk calls answered.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

measSwitchIsupOutgoingAnsiTrunkCallAttempts 1.3.6.1.4.1.4618.1.2.3.2.1.4
Switch Isup Outgoing Ansi Trunk Call Attempts. The number of outgoing ISUP-ANSi trunk call requests.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

measSwitchIsupOutgoingAnsiTrunkCallAnswered 1.3.6.1.4.1.4618.1.2.3.2.1.5
Switch Isup Outgoing Ansi Trunk Call Answered. The number of outgoing ISUP-ANSI trunk calls answered.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

measSwitchIsupIncomingItutTrunkCallAttempts 1.3.6.1.4.1.4618.1.2.3.2.1.6
Switch Isup Incoming Itut Trunk Call Attempts. The number of incoming ISUP-ITUT trunk call requests.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

measSwitchIsupIncomingItutTrunkCallAnswered 1.3.6.1.4.1.4618.1.2.3.2.1.7
Switch Isup Incoming Itut Trunk Call Answered. The number of incoming ISUP-ITUT trunk calls answered.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

measSwitchIsupOutgoingItutTrunkCallAttempts 1.3.6.1.4.1.4618.1.2.3.2.1.8
Switch Isup Outgoing Itut Trunk Call Attempts. The number of outgoing ISUP-ITUT trunk call requests.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

measSwitchIsupOutgoingItutTrunkCallAnswered 1.3.6.1.4.1.4618.1.2.3.2.1.9
Switch Isup Outgoing Itut Trunk Call Answered. The number of outgoing ISUP-ITUT trunk calls answered.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

measSwitchIsupFailCallDataSuspect 1.3.6.1.4.1.4618.1.2.3.2.2.1
Switch Isup Fail Call Data Suspect. Boolean value indicating if the measurement data set is suspect. Suspect data is that which may or may not be accurate and cannot be verified accurate due to a some condition that occurred during the collection inte
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

measSwitchIsupFailCallAnsiMatchingLoss 1.3.6.1.4.1.4618.1.2.3.2.2.2
Switch Isup Fail Call Ansi Matching Loss. The number of calls ISUP-ANSI trunk calls that fail to find a linked cross-connect within XCMs on any stage of the call.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

measSwitchIsupFailCallAnsiNoCircuit 1.3.6.1.4.1.4618.1.2.3.2.2.3
Switch Isup Fail Call Ansi No Circuit. The number of ISUP-ANSI calls that cannot forwarded on a trunk because: * No idle PRI trunks available * No cross-connect available between XCMs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

measSwitchIsupFailCallAnsiCalledPartyLineBusy 1.3.6.1.4.1.4618.1.2.3.2.2.4
Switch Isup Fail Call Ansi Called Party Line Busy. The number of ISUP-ANSI calls that result in a called party busy indication returned to the caller.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

measSwitchIsupFailCallAnsiIneffectiveMachineAttempts 1.3.6.1.4.1.4618.1.2.3.2.2.5
Switch Isup Fail Call Ansi Ineffective Machine Attempts. The number of ISUP-ANSI call ineffective machine attempts that have not been associated with any of the following: * Matching loss * No circuit * Called party line busy.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

measSwitchIsupFailCallItutMatchingLoss 1.3.6.1.4.1.4618.1.2.3.2.2.6
Switch Isup Fail Call Itut Matching Loss. The number of calls ISUP-ITUT trunk calls that fail to find a linked cross-connect within XCMs on any stage of the call.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

measSwitchIsupFailCallItutNoCircuit 1.3.6.1.4.1.4618.1.2.3.2.2.7
Switch Isup Fail Call Itut No Circuit. The number of ISUP-ITUT calls that cannot be forwarded on a trunk because: * No idle PRI trunks available * No cross-connect available between XCMs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

measSwitchIsupFailCallItutCalledPartyLineBusy 1.3.6.1.4.1.4618.1.2.3.2.2.8
Switch Isup Fail Call Itut Called Party Line Busy. The number of ISUP-ITUT calls that result in a called party busy indication returned to the caller.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

measSwitchIsupFailCallItutIneffectiveMachineAttempts 1.3.6.1.4.1.4618.1.2.3.2.2.9
Switch Isup Fail Call Itut Ineffective Machine Attempts. The number of ISUP-ITUT call ineffective machine attempts that have not been associated with any of the following: * Matching loss * No circuit * Called party line busy.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

measSwitchPriDataSuspect 1.3.6.1.4.1.4618.1.2.3.2.3.1
Switch Primary Data Suspect. Boolean value indicating if the measurement data set is suspect. Suspect data is that which may or may not be accurate and cannot be verified accurate due to a some condition that occurred during the collection interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

measSwitchPriIncomingIsdnPRICallAttempts 1.3.6.1.4.1.4618.1.2.3.2.3.2
Switch PRI Incoming ISDN PRI Call Attempts. The number of Incoming ISDN trunk call requests.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

measSwitchPriIncomingIsdnPRICallAnswered 1.3.6.1.4.1.4618.1.2.3.2.3.3
Switch PRI Incoming ISDN PRI Call Answered. The number of Incoming ISDN trunk calls answered.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

measSwitchPriFailCallDataSuspect 1.3.6.1.4.1.4618.1.2.3.2.4.1
Switch ISDN PRI Fail Call Data Suspect. Boolean value indicating if the measurement data set is suspect. Suspect data is that which may or may not be accurate and cannot be verified accurate due to a some condition that occurred during the collection
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

measSwitchPriFailCallMatchingLoss 1.3.6.1.4.1.4618.1.2.3.2.4.2
Switch ISDN PRI Fail Call Matching Loss. The number of calls PRI trunk calls that fail to find a linked cross-connect within XCM on any stage of the call.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

measSwitchPriFailCallNoCircuit 1.3.6.1.4.1.4618.1.2.3.2.4.3
Switch ISDN PRI Fail Call No Circuit. The number of PRI calls that cannot be forwarded on a trunk because: * No idle PRI trunks available * No cross-connect available between XCMs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

measSwitchPriFailCallCalledPartyLineBusy 1.3.6.1.4.1.4618.1.2.3.2.4.4
Switch ISDN PRI Fail Call Called Party Line Busy. The number of PRI calls that result in a called party busy indication returned to the caller.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

measSwitchPriFailCallIneffectiveMachineAttempts 1.3.6.1.4.1.4618.1.2.3.2.4.5
Switch ISDN PRI Fail Call Ineffective Machine Attempts. The number of PRI call ineffective machine attempts that have not been associated with any of the following: * Matching loss * No circuit * Called party line busy.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

xconnectCfgTable 4.1
XConnext Table. Information about XConnect(s) in MSSC are provided in this table. The index for this table is xconnectId(Integer).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    XconnectCfgEntry

xconnectCfgEntry 4.1.1
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  XconnectCfgEntry  

xconnectId 4.1.1.1
Xconnect id. Can be any integer 1-65535.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

xconnectName 4.1.1.2
Xconnect name. Can be any combination of alphanumeric characters. Spaces are not allowed and cannot exceed 15 characters.
Status: mandatory Access: read-write
OBJECT-TYPE    
  NameString  

xconnectIPAddr 4.1.1.3
Xconnect IP address. Submit in xxx.xxx.xxx.xxx format.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

xconnectTCPPort 4.1.1.4
Xconnect TCP port. Can be any integer 1-65535.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

xconnectRowStatus 4.1.1.5
Current Status (configurational Status) of this XConnect. To Configure this Link, the only option is 'CREATEANDWAIT' To Delete this Link, the only option is 'DESTROY' For the 'GET' Operation, the possible options are 1) active 2) notinservice 3) not
Status: mandatory Access: read-write
OBJECT-TYPE    
  RowStatus  

xconnectOpStatus 4.1.1.6
Current Status (Operational Status) of this XConnect. 'SET' Operation is NOT APPLICABLE. For the 'GET' Operation, the possible options are 1) active 2) down
Status: mandatory Access: read-only
OBJECT-TYPE    
  OpStatus  

xlinkCfgTable 4.2
XLink Table. Information about XLink(s) in MSSC are provided in this table.This table has six indices: xconnectIdEndA, slotIdEndA, portIdEndA,xconnectIdEndB, xconnectIdEndB,slotIdEndB,portIdEndB (all Integers)
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    XlinkCfgEntry

xlinkCfgEntry 4.2.1
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  XlinkCfgEntry  

xconnectIdEndA 4.2.1.1
Xconnect id for one end. Can be any integer 1-65535.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

slotIdEndA 4.2.1.2
Slot Id of one end.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

portIdEndA 4.2.1.3
Port id of one end.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

xconnectIdEndB 4.2.1.4
Xconnect id for the other end. Can be any integer 1-65535.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

slotIdEndB 4.2.1.5
Slot Id of the other end.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

portIdEndB 4.2.1.6
Port id of the other end.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

xlinkConnectionType 4.2.1.7
Connection Type between the Xconnects The possible options are : 1) Unchannelised DS3 (ut3) 2) Channelised DS3 (t3)
Status: mandatory Access: read-write
OBJECT-TYPE    
  ConnectionType  

xlinkRowStatus 4.2.1.8
Current Status (configurational Status) of this XCONNECT Link. To Configure this Link, the only option is 'CREATEANDWAIT' To Delete this Link, the only option is 'DESTROY' For the 'GET' Operation, the possible options are 1) active 2) notinservice 3
Status: mandatory Access: read-write
OBJECT-TYPE    
  RowStatus  

xlinkOpStatus 4.2.1.9
Current Status (Operational Status) of this XConnect Link. 'SET' Operation is NOT APPLICABLE. For the 'GET' Operation, the possible options are 1) active 2) down
Status: mandatory Access: read-only
OBJECT-TYPE    
  OpStatus  

xlinkMgmntTable 4.3
XLink Management Table. This table has six indices: xconnectIdEndA, slotIdEndA, portIdEndA,xconnectIdEndB, xconnectIdEndB,slotIdEndB,portIdEndB (all Integers)
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    XlinkMgmntEntry

xlinkMgmntEntry 4.3.1
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  XlinkMgmntEntry  

xconnIdEndA 4.3.1.1
Xconnect id for one end. Can be any integer 1-65535.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

xconnSlotIdEndA 4.3.1.2
Slot Id of one end.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

xconnPortIdEndA 4.3.1.3
Port id of one end.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

xconnIdEndB 4.3.1.4
Xconnect id for the other end. Can be any integer 1-65535.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

xconnSlotIdEndB 4.3.1.5
Slot Id of the other end.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

xconnPortIdEndB 4.3.1.6
Port id of the other end.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

xlinkMgmntCmd 4.3.1.7
Management Command for Enabling/Disabling XLink The possible options are : 1) Enable 2) Disable [default]
Status: mandatory Access: read-write
OBJECT-TYPE    
  EnableOperation  

cdrConfig 1.3.6.1.4.1.4618.1.2.4.1
OBJECT IDENTIFIER    

cdrBafConfig 1.3.6.1.4.1.4618.1.2.4.2
OBJECT IDENTIFIER    

cdrFileConfig 1.3.6.1.4.1.4618.1.2.4.3
OBJECT IDENTIFIER    

cdrFileInfo 1.3.6.1.4.1.4618.1.2.4.4
OBJECT IDENTIFIER    

cdrMgmntCmdGroup 1.3.6.1.4.1.4618.1.2.4.5
OBJECT IDENTIFIER    

cdrLongDurCallGenTime 1.3.6.1.4.1.4618.1.2.4.1.1
The Time of the day that the syatem will generate the long duration call. CDR Format ( HHMM ) Valid time of the day from 0000 - 2359
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2359  

cdrAppendModule801 1.3.6.1.4.1.4618.1.2.4.2.1
Indicates if the Armillaire Proprietary Module 801 should be appended to those BAF Records. Text Format ( Not Case sensitive ) Valid values : yes, no
Status: mandatory Access: read-write
OBJECT-TYPE    
  Bool  

cdrSensorId 1.3.6.1.4.1.4618.1.2.4.2.2
AMA Sensor Id code of the switch. Valid values 000001-999998 for Set. If not configured then Default value is 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..999998  

cdrRecordingOfficeId 1.3.6.1.4.1.4618.1.2.4.2.3
AMA Record Id code of the switch. Valid values 000001-999998 For Set. If not configured then Default value is 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..999998  

cdrFileInterval 1.3.6.1.4.1.4618.1.2.4.3.1
How often the cdr file being generated. Valid values 1-86400 seconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..86400  

cdrFileRecLimit 1.3.6.1.4.1.4618.1.2.4.3.2
Maximum Nubler of BAF records in a CDR File. Valid values 1,677,215
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..86400  

cdrFileSourceId 1.3.6.1.4.1.4618.1.2.4.3.3
This Source Component id specifies the network element for receiving of cdr files according to AMADNS. This id will be part of first node of CDR filename. Valid values 01-4095 For Set. If not configured then Default value is 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..4095  

cdrFileDestinationType 1.3.6.1.4.1.4618.1.2.4.3.4
This Destination Component type specifies the network element for receiving of cdr files according to AMADNS. This type will be part of second node of CDR filename. Valid values 01-15 For Set. If not configured then Default value is 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..15  

cdrFileDestinationId 1.3.6.1.4.1.4618.1.2.4.3.5
This Destination Component Id specifies the network element for receiving of cdr files according to AMADNS. This type will be part of second node of CDR filename. Valid values 01-4095 for Set. If not configured then Default value is 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..4095  

cdrFileQuery 1.3.6.1.4.1.4618.1.2.4.4.1
Number of the desired CDR file. set file number to update the cdr file info.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

cdrFileName 1.3.6.1.4.1.4618.1.2.4.4.2
Name of the desired CDR file. Can be any combination of alphanumeric characters. Spaces are not allowed. Filename cannot exceed 24 characters.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..24)  

cdrFileStatus 1.3.6.1.4.1.4618.1.2.4.4.3
Status of the desired CDR file
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdrFileCreateDate 1.3.6.1.4.1.4618.1.2.4.4.4
Creation date of the desired CDR file FORMAT:2000/01/26
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..32)  

cdrFileCreateTime 1.3.6.1.4.1.4618.1.2.4.4.5
Creation time of the desired CDR file FORMAT: 20:12:23
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..32)  

cdrFileRecordNum 1.3.6.1.4.1.4618.1.2.4.4.6
Record number of the desired CDR file
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdrFileAcknowledge 1.3.6.1.4.1.4618.1.2.4.4.7
Acknowledgement of the CDR file. The input should be the File Name.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..255)  

cdrGenMgmntCmd 1.3.6.1.4.1.4618.1.2.4.5.1
This command is used to turn on the CDR generation for the entire switch.If switch CDR generation is enabled then CDR generation can be enabled/disabled on Trunk Group. The possible options are : 1) Enable 2) Disable [default]
Status: mandatory Access: read-write
OBJECT-TYPE    
  EnableOperation  

cdrMngmtTrnkGrpTable 1.3.6.1.4.1.4618.1.2.4.5.2
CDR Management Command for Trunk group Table. The index for this table is cdrTrnkGrpId (integer)
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CdrMngmtTrnkGrpEntry

cdrMngmtTrnkGrpEntry 1.3.6.1.4.1.4618.1.2.4.5.2.1
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CdrMngmtTrnkGrpEntry  

cdrTrnkGrpId 1.3.6.1.4.1.4618.1.2.4.5.2.1.1
The trunk Group Id.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

cdrTrnkGrpdirection 1.3.6.1.4.1.4618.1.2.4.5.2.1.2
The Direction
Status: mandatory Access: read-write
OBJECT-TYPE    
  CdrFlag  

cdrTrnkGrpMgmntCmd 1.3.6.1.4.1.4618.1.2.4.5.2.1.3
This command is used to turn on the CDR generation on the Trunk Group. The possible options are : 1) Enable 2) Disable [default]
Status: mandatory Access: read-write
OBJECT-TYPE    
  EnableOperation  

modemStatusTable 1.3.6.1.4.1.4618.1.2.5.1.1
Faulty Modem Detection Table. This Table provides information about all the potentially faulty modems in MSSC. This table has two indices: faultModemTrnkId and faultModemChnlId (both Integer)
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ModemStatusEntry

modemStatusEntry 1.3.6.1.4.1.4618.1.2.5.1.1.1
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ModemStatusEntry  

faultModemTrnkId 1.3.6.1.4.1.4618.1.2.5.1.1.1.1
The terminating Channel trunk Id.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

faultModemChnlId 1.3.6.1.4.1.4618.1.2.5.1.1.1.2
The terminating Channel Channel Id.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

faultModemRepnum 1.3.6.1.4.1.4618.1.2.5.1.1.1.3
Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

faultModemReset 1.3.6.1.4.1.4618.1.2.5.1.1.1.4
The Option for Reseting the terminating Channel. A 'GET' operation on this object will display the default value [no]. The possible option for 'SET' operation is 1) YES
Status: mandatory Access: read-write
OBJECT-TYPE    
  ModemResetStatus  

lrnTable 1.3.6.1.4.1.4618.1.2.5.2.1
Local Routing Number Table. This Table provides information about Local Routing number in MSSC. This table has the index lrnId (Integer)
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LrnEntry

lrnEntry 1.3.6.1.4.1.4618.1.2.5.2.1.1
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  LrnEntry  

lrnNum 1.3.6.1.4.1.4618.1.2.5.2.1.1.1
The Local Routing Number (LRN) Id.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..10)  

lrnRowStatus 1.3.6.1.4.1.4618.1.2.5.2.1.1.2
The Local Routing Number (LRN) Number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  LrnRowStatus  

switchDSPCfgTable 1.3.6.1.4.1.4618.1.2.5.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SwitchDSPCfgEntry

switchDSPCfgEntry 1.3.6.1.4.1.4618.1.2.5.3.1.1
DSP Configuration Table. This Table provides information about the DSP card(s) in MSSC. This table has two indices: switchDSPXconnId and switchDSPSlotId (both Integer)
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SwitchDSPCfgEntry  

switchDSPXconnId 1.3.6.1.4.1.4618.1.2.5.3.1.1.1
Xconnect Id for which DSP card is being configured
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

switchDSPSlotId 1.3.6.1.4.1.4618.1.2.5.3.1.1.2
The Slot id at which the DSP card is being configured.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

switchDSPCardType 1.3.6.1.4.1.4618.1.2.5.3.1.1.3
The card Type. The possible options are : 1) DSP2B 2) DSP2C
Status: mandatory Access: read-write
OBJECT-TYPE    
  DSPCardType  

switchDSPCfgRowStatus 1.3.6.1.4.1.4618.1.2.5.3.1.1.4
Current Status (configurational Status) of this Switch DSP. To Configure this Link, the only option is 'CREATEANDWAIT' To Delete this Link, the only option is 'DESTROY' For the 'GET' Operation, the possible options are 1) active 2) notinservice 3) n
Status: mandatory Access: read-write
OBJECT-TYPE    
  RowStatus  

switchDSPCfgOpStatus 1.3.6.1.4.1.4618.1.2.5.3.1.1.5
Current Status (Operational Status) of this Switch DSP. 'SET' Operation is NOT APPLICABLE. For the 'GET' Operation, the possible options are 1) active 2) down
Status: mandatory Access: read-only
OBJECT-TYPE    
  OpStatus  

switchFeatureTGCfgTable 1.3.6.1.4.1.4618.1.2.5.4.1
Trunk Group Feature Table. This Table provides information about the Trunk Group Feature(s) in MSSC. This table has one indices: switchFeatureTGId (Integer)
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SwitchFeatureTGCfgEntry

switchTGGrpCfgEntry 1.3.6.1.4.1.4618.1.2.5.4.1.1
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SwitchFeatureTGCfgEntry  

switchFeatureTGId 1.3.6.1.4.1.4618.1.2.5.4.1.1.1
Denotes Id for this trunk group.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

switchFeatureTGName 1.3.6.1.4.1.4618.1.2.5.4.1.1.2
Denotes Name of this trunk group. The Name is a string of length 8. The first two characters of Name have to be an alphabhet. The next 6 characters are numeric. An example of a valid Trunk Group Name is ab123456. NOTE: This format needs to strictly fo
Status: mandatory Access: read-only
OBJECT-TYPE    
  NameString  

switchFeatureTGType 1.3.6.1.4.1.4618.1.2.5.4.1.1.3
Denotes Trunk group type. Possible values for Trunk group are: 1. ss7 2. isdn
Status: mandatory Access: read-only
OBJECT-TYPE    
  TrnkGrpType  

switchFeatureTGFeatureEC 1.3.6.1.4.1.4618.1.2.5.4.1.1.4
Denotes Echo Cancellation feature. Possible Values are: 1. Enable 2. Disable NOTE: If TrunkGrpType is ISDN, then Enabling Echo Cancellation feature is an INVALID Operation. A 'GET' Operation at this object will ALWAYS result in the default value [di
Status: mandatory Access: read-write
OBJECT-TYPE    
  TGFeature  

switchFeatureTGFeatureCOMPRESS 1.3.6.1.4.1.4618.1.2.5.4.1.1.5
Denotes Compression feature. Possible Values are: 1. Enable 2. Disable NOTE: if TrunkGrpType is ISDN, then Enabling Compression feature, is an INVALID Operation. A 'GET' Operation at this object will ALWAYS result in the default value [disable] bein
Status: mandatory Access: read-write
OBJECT-TYPE    
  TGFeature  

switchFeatureTGFeatureSS 1.3.6.1.4.1.4618.1.2.5.4.1.1.6
Denotes Silent Supression feature. Possible Values are: 1. Enable 2. Disable NOTE: If TrunkGrpType is ISDN, the Enabling Silent Supression feature, is an INVALID Operation. A 'GET' Operation at this object will ALWAYS result in the default value [di
Status: mandatory Access: read-write
OBJECT-TYPE    
  TGFeature  

switchFeatureTGFeatureCNIS 1.3.6.1.4.1.4618.1.2.5.4.1.1.7
Denotes Caller Number Identitication Service (CNIS) feature. Possible Values are: 1. Enable 2. Disable NOTE: If TrunkGrpType is SS7, then Enabling Caller Number Identitication Service, is an INVALID Operation. A 'GET' Operation at this object will AL
Status: mandatory Access: read-write
OBJECT-TYPE    
  TGFeature  

switchOver 1.3.6.1.4.1.4618.1.2.6.1.1.1
FT Switch Over command. The possible options are 1) FT_SIG 2) FT_ICC 3) FT_ISDN 4) FT_SPHR 5) FT_LM Select any one and set that option.
Status: mandatory Access: read-write
OBJECT-TYPE    
  FTswitchOver  

logGenTime 7.1.1
Switch Log Generation Time. The Parameter Time-interval determines the period of generating new log files. When the time interval is reached, all the current open log files are closed and new log files are generated for future log. The unit for the ti
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..120  

logPurgeTime 7.1.2
Switch Log Deletion Time. The Parameter Time-interval determines the period of purging old log files. When the time interval is reached, all the log files older than this time-interval are deleted. The unit for the time-interval is 'minute'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..120  

enablelogGen 7.2.1
This option enables the log file Generation. 1) ALARM_LOG 2) AUDIT_LOG 3) MEAS_LOG 4) DIAG_LOG 5) SCRTY_LOG 6) EVENT_LOG 7) BILL_LOG 8) EMP_LOG 9) LOG_ALL Choose any one from drop down list...
Status: mandatory Access: read-write
OBJECT-TYPE    
  LogFileEnDis  

disableLogGen 7.2.2
This option disables the log file Generation. 1) ALARM_LOG 2) AUDIT_LOG 3) MEAS_LOG 4) DIAG_LOG 5) SCRTY_LOG 6) EVENT_LOG 7) BILL_LOG 8) EMP_LOG 9) LOG_ALL Choose any one from drop down list..
Status: mandatory Access: read-write
OBJECT-TYPE    
  LogFileEnDis  

logAttribute 7.3.1
Allows the user to inquire about the current LOG file attributes. The possible options are : 1) ALARM_LOG 2) AUDIT_LOG 3) MEAS_LOG 4) DIAG_LOG 5) SCRTY_LOG 6) EVENT_LOG 7) BILL_LOG 8) EMP_LOG Choose any one from drop down list..
Status: mandatory Access: read-write
OBJECT-TYPE    
  LogFileAttr  

logFileSize 7.3.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

logFileDuration 7.3.3
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

logFileStatus 7.3.4
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ss7LnkTraceTable 1.3.6.1.4.1.4618.1.2.6.3.1.1
This Table is specified for Applying Trace Function for any SS7 Link(s). The index of this table is ss7LnkId (integer)
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ss7LnkTraceEntry

ss7LnkTraceEntry 1.3.6.1.4.1.4618.1.2.6.3.1.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ss7LnkTraceEntry  

ss7LnkId 1.3.6.1.4.1.4618.1.2.6.3.1.1.1.1
The SS7 link Id on which the Trace Function is to be applied.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ss7LnkLog 1.3.6.1.4.1.4618.1.2.6.3.1.1.1.2
This option displays weather log Function is enabled for the specified SS7 Link.
Status: mandatory Access: read-only
OBJECT-TYPE    
  LogType  

ss7LnkEnable 1.3.6.1.4.1.4618.1.2.6.3.1.1.1.3
This option enables/disables the trace Function for the specified SS7 Link. The possible option are: 1) Enable 2) Disable [default]
Status: mandatory Access: read-write
OBJECT-TYPE    
  EnableTrace  

ss7RouteTraceTable 1.3.6.1.4.1.4618.1.2.6.3.2.1
This Table is specified for Applying Trace Function for any SS7 Route(s). The index of this table is ss7RouteDpc (Integer)
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ss7RouteTraceEntry

ss7RouteTraceEntry 1.3.6.1.4.1.4618.1.2.6.3.2.1.1
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ss7RouteTraceEntry  

ss7RouteDpc 1.3.6.1.4.1.4618.1.2.6.3.2.1.1.1
The SS7 Point code. The trace Function is to be applied on this route.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ss7RouteLog 1.3.6.1.4.1.4618.1.2.6.3.2.1.1.2
This option displays weather Log Function is enabled for the specified SS7 Route.
Status: mandatory Access: read-only
OBJECT-TYPE    
  LogType  

ss7RouteEnable 1.3.6.1.4.1.4618.1.2.6.3.2.1.1.3
This option enables/disables the trace Functions for the specified SS7 Route. The possible option are: 1) Enable 2) Disable [default]
Status: mandatory Access: read-write
OBJECT-TYPE    
  EnableTrace  

isdnTrunkTraceTable 1.3.6.1.4.1.4618.1.2.6.3.3.1
This Table is specified for Applying Trace Function for any ISDN Trunk(s). The index of this table is isdnTrnkId (Integer)
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IsdntrunkTraceEntry

isdnTrunkTraceEntry 1.3.6.1.4.1.4618.1.2.6.3.3.1.1
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  IsdntrunkTraceEntry  

isdnTrnkId 1.3.6.1.4.1.4618.1.2.6.3.3.1.1.1
The ISDN Trunk Id for which the Trace Function is to be applied.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

isdnTrunkLog 1.3.6.1.4.1.4618.1.2.6.3.3.1.1.2
This option displays weather log Function is enabled for the specified ISDN Trunk.
Status: mandatory Access: read-only
OBJECT-TYPE    
  LogType  

isdnTrunkEnable 1.3.6.1.4.1.4618.1.2.6.3.3.1.1.3
This option enables/disables the trace Functions for the specified ISDN Trunk. The possible option are: 1) Enable 2) Disable [default]
Status: mandatory Access: read-write
OBJECT-TYPE    
  EnableTrace  

auditISDNTrnkTable 1.1.1
Audit ISDN Trunk Table. This table has one index: auditTrnkId (Integer)
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AuditISDNTrnkCfgEntry

auditISDNTrnkCfgEntry 1.1.1.1
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AuditISDNTrnkCfgEntry  

auditTrnkId 1.1.1.1.1
The ISDN Trunk Id on which the audit operation is being applied.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

auditISDNTrnk 1.1.1.1.2
This Object is set to Apply Audit on this particular ISDN Trunk. The possible option for 'SET' is 1) audit A 'GET' Operation on this object would result the default value 'no action' being displayed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  AuditOperation  


auditDPCTable 1.1.3
The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AuditDPCCfgEntry

auditDPCCfgEntry 1.1.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AuditDPCCfgEntry  

auditPointCode 1.1.3.1.1
The Point Code on which the audit operation is being applied.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

auditPointCodeType 1.1.3.1.2
The Point Code Type. Ansi/Itu.
Status: mandatory Access: read-only
OBJECT-TYPE    
  AuditType  

auditDPC 1.1.3.1.3
This Object is set to Apply Audit on this particular DPC. The possible option for 'SET' is 1) audit A 'GET' Operation on this object would result the default value 'no action' being displayed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  AuditOperation  

auditPeriodGrp 1.1.4
OBJECT IDENTIFIER    

auditTimePeriod 1.1.4.1
The Audit Period for which the audit operation is being applied.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

auditPeriod 1.1.4.2
This Object is set to Apply Audit for this particular Period. The possible option for 'SET' is 1) audit A 'GET' Operation on this object would result the default value 'no action' being displayed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  AuditOperation  

statusLM1ProcId 1.3.6.1.4.1.4618.1.2.6.4.1.1
Indicates the current status of FT_LM: Process Id 512.
Status: mandatory Access: read-only
OBJECT-TYPE    
  ProcessStatus  

statusLM2ProcID 1.3.6.1.4.1.4618.1.2.6.4.1.2
Indicates the current status of FT_LM: Process Id 511.
Status: mandatory Access: read-only
OBJECT-TYPE    
  ProcessStatus  

statusICC1ProcId 1.3.6.1.4.1.4618.1.2.6.4.1.3
Indicates the current status of FT_ICC : Process Id 480.
Status: mandatory Access: read-only
OBJECT-TYPE    
  ProcessStatus  

statusICC2ProcId 1.3.6.1.4.1.4618.1.2.6.4.1.4
Indicates the current status of FT_ICC: Process Id 496.
Status: mandatory Access: read-only
OBJECT-TYPE    
  ProcessStatus  

statusISDN1ProcId 1.3.6.1.4.1.4618.1.2.6.4.1.5
Indicates the current status of FT_ISDN: Process Id 476.
Status: mandatory Access: read-only
OBJECT-TYPE    
  ProcessStatus  

statusISDN2ProcId 1.3.6.1.4.1.4618.1.2.6.4.1.6
Indicates the current status of FT_ISDN: Process Id 472.
Status: mandatory Access: read-only
OBJECT-TYPE    
  ProcessStatus  

statusSPHR1ProcId 1.3.6.1.4.1.4618.1.2.6.4.1.7
Indicates the current status of FT_SPHR: Process Id 448.
Status: mandatory Access: read-only
OBJECT-TYPE    
  ProcessStatus  

statusSPHR2ProcId 1.3.6.1.4.1.4618.1.2.6.4.1.8
Indicates the current status of FT_SPHR: Process Id 464.
Status: mandatory Access: read-only
OBJECT-TYPE    
  ProcessStatus  

statusSIG1ProcId 1.3.6.1.4.1.4618.1.2.6.4.1.9
Indicates the current status of FT_SIG: Process Id 384.
Status: mandatory Access: read-only
OBJECT-TYPE    
  ProcessStatus  

statusSIG2ProcId 1.3.6.1.4.1.4618.1.2.6.4.1.10
Indicates the current status of FT_SIG: Process Id 400.
Status: mandatory Access: read-only
OBJECT-TYPE    
  ProcessStatus  

statusMTP21ProcId 1.3.6.1.4.1.4618.1.2.6.4.1.11
Indicates the current status of Mtp2: Process Id 320.
Status: mandatory Access: read-only
OBJECT-TYPE    
  ProcessStatus  

statusMTP22ProcId 1.3.6.1.4.1.4618.1.2.6.4.1.12
Indicates the current status of Mtp2: Process Id 321.
Status: mandatory Access: read-only
OBJECT-TYPE    
  ProcessStatus  

statusMTP23ProcId 1.3.6.1.4.1.4618.1.2.6.4.1.13
Indicates the current status of Mtp2 : Process Id 322.
Status: mandatory Access: read-only
OBJECT-TYPE    
  ProcessStatus  

statusMTP24ProcId 1.3.6.1.4.1.4618.1.2.6.4.1.14
Indicates the current status of Mtp2: Process Id 323.
Status: mandatory Access: read-only
OBJECT-TYPE    
  ProcessStatus  

ethernetConnStatus 1.3.6.1.4.1.4618.1.2.6.5.1
Current Status of the Ethernet Connection to MSSC. 'SET' Operation is NOT APPLICABLE. For the 'GET' Operation, the possible options are 1) active 2) down
Status: mandatory Access: read-only
OBJECT-TYPE    
  EthernetConnStatus  

trapOpc 1.3.6.1.4.1.4618.1.2.7.1.1
Indicate the point code of the switch that send trap
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..16777215  

trapXconnectId 1.3.6.1.4.1.4618.1.2.7.1.2
Indicate the id of the xconnect that send trap
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trapLinkId 1.3.6.1.4.1.4618.1.2.7.1.3
Indicate the id of the link that abnormal situation
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trapSlotId 1.3.6.1.4.1.4618.1.2.7.1.4
Indicate the id of the slot that has abnormal situation
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trapPortId 1.3.6.1.4.1.4618.1.2.7.1.5
Indicate the id of the port that has abnormal situation
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trapTrunkId 1.3.6.1.4.1.4618.1.2.7.1.6
Indicate the id of the trunk that has abnormal situation
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trapInterfaceId 1.3.6.1.4.1.4618.1.2.7.1.7
Indicate the id of the interface that has abnormal situation
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trapChnlId 1.3.6.1.4.1.4618.1.2.7.1.8
Indicate the id of the channel that has abnormal situation
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trapDbId 1.3.6.1.4.1.4618.1.2.7.1.9
Indicate the id of the database that has abnormal situation
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trapLinkName 1.3.6.1.4.1.4618.1.2.7.1.10
Indicate the name of the link that has abnormal situation
Status: mandatory Access: read-only
OBJECT-TYPE    
  NameString  

trapSwitchName 1.3.6.1.4.1.4618.1.2.7.1.11
Indicate the name
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

trapCicvalue 1.3.6.1.4.1.4618.1.2.7.1.12
Indicate Circuit Identification Code value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trapCicrange 1.3.6.1.4.1.4618.1.2.7.1.13
Integer identifying the range ex. no. cics.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trapCause 1.3.6.1.4.1.4618.1.2.7.1.14
Cause indicates Causes for ISUP related alarms: BLOCKING UNBLOCKING INVALIDRNG GROUPBLOCKING GROUPUNBLOCKACK RESETCIRCUIT RESETRELCOMP GROUPRESETCIRCUIT GROUPRESETACK CIRCUITQUERYRESP VALIDATIONSUCCESS VALIDATIONFAILED VALIDATIONFAILEDWRONGCLLI OTHERS
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..33)  

trapDpc 1.3.6.1.4.1.4618.1.2.7.1.15
Indicate the point code of the switch
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..16777215  

trapCdrFileSeqNum 1.3.6.1.4.1.4618.1.2.7.1.16
Indicate the sequence number of the cdr file that has abnormal situation
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trapCdrFileName 1.3.6.1.4.1.4618.1.2.7.1.17
Indicates the CDR file name or file directory. Can be any combination of alphanumeric characters. Spaces are allowed and cannot exceed 255 characters.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..255)  

trapMeasErrCause 1.3.6.1.4.1.4618.1.2.7.1.18
Indicates the Measurement Files error operation cause
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trapMeasErrNum 1.3.6.1.4.1.4618.1.2.7.1.19
Indicates the Measurement Files error number of the operation
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trapRepeatNum 1.3.6.1.4.1.4618.1.2.7.1.20
Indicate the count that trap has occured
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trapSeverity 1.3.6.1.4.1.4618.1.2.7.1.21
Indicate the severity of the sent trap
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

trapProcessId 1.3.6.1.4.1.4618.1.2.7.1.22
Indicate the process id for that trap has occured
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trapBucketSize 1.3.6.1.4.1.4618.1.2.7.1.23
Indicate the process Bucket size for the Process for which the trap has occured
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trapNode1Id 1.3.6.1.4.1.4618.1.2.7.1.24
Indicates the src Xconnect Id which cause congestion
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trapNode2Id 1.3.6.1.4.1.4618.1.2.7.1.25
Indicates the dest Xconnect Id which cause congestion
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trapRoutename 1.3.6.1.4.1.4618.1.2.7.1.26
indicate the xoute name that is not found between the xlink
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

trapMeasFileName 1.3.6.1.4.1.4618.1.2.7.1.27
indicate the Measurement file name. Can be any combination of alphanumeric characters. Spaces are allowed and cannot exceed 64 characters.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..255)  

trapDirectory 1.3.6.1.4.1.4618.1.2.7.1.28
indicate the Cdr File Directory
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

trapProcessorId 1.3.6.1.4.1.4618.1.2.7.1.29
Indicates the Process Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trapLogFileName 1.3.6.1.4.1.4618.1.2.7.1.30
Indicate the Log file name. Can be any combination of alphanumeric characters. Spaces are allowed and cannot exceed 64 characters.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..255)  

trapLogErrcause 1.3.6.1.4.1.4618.1.2.7.1.31
Indicate the Log error operation cause
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..64)  

trapLogErrNo 1.3.6.1.4.1.4618.1.2.7.1.32
Indicate the log cdr error number of the operation
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trapPsuNo 1.3.6.1.4.1.4618.1.2.7.1.33
Indicate the Power supply number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trapIntId 1.3.6.1.4.1.4618.1.2.7.1.34
Indicate the Power supply number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trapIntfcId 1.3.6.1.4.1.4618.1.2.7.1.35
Indicate the Power supply number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trapLanId 1.3.6.1.4.1.4618.1.2.7.1.36
Indicate theLan ID
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  


trapSwitchId1 1.3.6.1.4.1.4618.1.2.7.1.38
Indicate the xconnect Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trapSwitchId2 1.3.6.1.4.1.4618.1.2.7.1.39
Indicate the xconnect Id
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trapProcInstNo 1.3.6.1.4.1.4618.1.2.7.1.40
Indicate the Process instance number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trapProcName 1.3.6.1.4.1.4618.1.2.7.1.41
Indicate the Process name that Failed
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..15)  

trapFanNo 1.3.6.1.4.1.4618.1.2.7.1.42
Indicate the Fan Number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trapUserName 1.3.6.1.4.1.4618.1.2.7.1.43
indicates the user login Name
Status: mandatory Access: read-only
OBJECT-TYPE    
  NameString  

trapBitMapStatus 1.3.6.1.4.1.4618.1.2.7.1.44
Indicates the Bit Map Status of the Cics that are blocked. This Status is only valid for GROUPBLOCKING (I.e range >1)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..33)  

alarmTraps 1.3.6.1.4.1.4618.1.2.7.2.1
OBJECT IDENTIFIER    

genswitchSnmpAgentReadyNotify 1
Info : SNMP Agent is up
TRAP-TYPE    

genConsoleLoginNotify 2
Info : A user has successfully logged in from console
TRAP-TYPE    

genConsoleLogoutNotify 3
Info : A user has successfully logged out from console
TRAP-TYPE    

genProcessBufOverflowNotify 4
Info : Process ran out of buffer
TRAP-TYPE    

genProcessBufOverflowRecoverNotify 5
Info : Process Recovered from Buffer Overflow
TRAP-TYPE    

genProcessHeapOverFlowNotify 6
Info : Process Heap OverFlow Detected
TRAP-TYPE    

genProcessHeapOverFlowRecoverNotify 7
Info : Recovered from Process Heap Overflow
TRAP-TYPE    

xconnectUpNotify 8
Info : switch has successfully brought up TCP/IP link between MSCG and AC 120 xconnect
TRAP-TYPE    

xconnectDnNotify 9
Info : switch has a failure on TCP/IP link between MSCG and AC120
TRAP-TYPE    

xconnectClkClearNotify 10
Info : Stratum Card is available
TRAP-TYPE    

xconnectClkFailNotify 11
Info : Stratum Card has either been removed or has failed
TRAP-TYPE    

xconnectBkplaneRefClkClearNotify 12
Info : Back Plane reference clock clear
TRAP-TYPE    

xconnectBkplaneRefClkFailNotify 13
Info : Back Plane reference clock fail
TRAP-TYPE    

xconnectInterfaceInServiceNotify 14
Info : Switch has successfully brought the specified interface to be in service
TRAP-TYPE    

xconnectInterfaceOutOfServiceNotify 15
Info : An interface card is out of service
TRAP-TYPE    

xconnectCardInsertionNotify 16
Info : A card is inserted in xconnect
TRAP-TYPE    

xconnectCardRemovalNotify 17
Info : A card is removed from xconnect
TRAP-TYPE    

xconnectIllegalCardTypeNotify 18
Info : Illegal Card Type
TRAP-TYPE    

xconnectIntfFarEndLOFNotify 19
Info : Interface Far end LOF
TRAP-TYPE    

xconnectIntfFarEndAISNotify 20
Info : Interface Far end AIS
TRAP-TYPE    

xconnectIntfNearEndLOFNotify 21
Info : Interface Near end LOF
TRAP-TYPE    

xconnectIntfNearEndLOSNotify 22
Info : Interface Near end LOS
TRAP-TYPE    

xconnectIntfCreateNotify 23
Info : Interface in AC120 has been created
TRAP-TYPE    

xconnectIntfDeleteNotify 24
Info : Interface in AC120 has been deleted
TRAP-TYPE    

xconnectXlinkAdjConClrNotify 25
Info : Xconnect Adjacent Congestion cleared
TRAP-TYPE    

xconnectXlinkAdjConNotify 26
Info : Xconnect Adjacent Congestion Notified
TRAP-TYPE    

xconnectXlinkRouteFailNotify 27
Info : Xpath not found between the Xlink
TRAP-TYPE    

xconnectPortUpNotify 28
Info : Port is Up
TRAP-TYPE    

xconnectCPUSwitchOverNotify 29
Info : XConnect CPU SwitchOver
TRAP-TYPE    

atmRAINotify 30
Info : ATM Remote Alarm Indication
TRAP-TYPE    

atmAISNotify 31
Info : ATM AIS
TRAP-TYPE    

atmLOFNotify 32
Info : ATM LOF
TRAP-TYPE    

atmLOSNotify 33
Info : ATM LOS
TRAP-TYPE    

mfdClearNotify 34
Info : A potential fault modem is cleared
TRAP-TYPE    

mfdDetectionNotify 35
Info : Faulty Modem: A Potential Faulty Modem has been Detected
TRAP-TYPE    

measFileReadyNotify 36
Info : Measurement file is ready for FTP
TRAP-TYPE    

measDiskOverCrtclThresholdNotify 37
Info : The partition that the measurement file resides on is over critical threshold.
TRAP-TYPE    

measFileMoveNotify 38
Info : Measurement file moved to secondary directory
TRAP-TYPE    

measFileMoveErrNotify 39
Info : Error in moving Measurement file to secondary directory
TRAP-TYPE    

measFileOpenErrNotify 40
Info : Measurement open file error
TRAP-TYPE    

measFileDeleteNotify 41
Info : Measurement file deleted
TRAP-TYPE    

measFileDeleteErrNotify 42
Info : Measurement delete file error
TRAP-TYPE    

cdrFileReadyNotify 43
Info :Cdr file is ready for Polling
TRAP-TYPE    

cdrDiskFullNotify 44
Info :CDR file disk usage reach critical threshold
TRAP-TYPE    

cdrFileOpenErrNotify 45
Info :CDR open file error
TRAP-TYPE    

cdrFileMoveErrNotify 46
Info : Error in moving CDR file from temp location to target CDR file location
TRAP-TYPE    

cdrDeleteErrNotify 47
Info : CDR file cannot be deleted
TRAP-TYPE    

cdrWriteHeaderErrNotify 48
Info :Error in writing CDR file header
TRAP-TYPE    

cdrWriteRecErrNotify 49
Info :Error in writing CDR record
TRAP-TYPE    

cdrErrFileLocErrNotify 50
Info: Invalid Cdr Directory
TRAP-TYPE    

cdrErrTempFileLocErrNotify 51
Info: Invalid Cdr Directory
TRAP-TYPE    

cdrFileSysErrNotify 52
Info: Cdr File System Operation error.
TRAP-TYPE    

cdrFileCloseErrNotify 53
Info: Error in closing CDR file
TRAP-TYPE    

cdrFileDelete5DaysNotify 54
Info: cdr files created within past 5 days are deleted
TRAP-TYPE    

ss7LinkUpNotify 55
Info : switch has successfully brought up ss7 mtp3 link
TRAP-TYPE    

ss7LinkDnNotify 56
Info : switch has a failure on ss7 mtp3 link
TRAP-TYPE    

ss7Mtp2LinkUpNotify 57
Info : switch has successfully brought up ss7 mtp2 link
TRAP-TYPE    

ss7Mtp2LinkDnNotify 58
Info : switch has a failure on ss7 mtp2 link
TRAP-TYPE    

ss7LinkEnterCongestionNotify 59
Info : the specified link has entered a congestion situation
TRAP-TYPE    

ss7LinkExitCongestionNotify 60
Info : the ss7 link has exited the congestion situation
TRAP-TYPE    

ss7InvalidSLCNotify 61
Info : Mtp3 invalid SLC configured.
TRAP-TYPE    

ss7ConcernedDpcPauseNotify 62
Info : Concerned DPC pause
TRAP-TYPE    

ss7ConcernedDpcResumeNotify 63
Info : Concerned DPC resume
TRAP-TYPE    

ss7ConcernedDpcRemUnAvailNotify 64
Info : Concerned DPC remote user unavailable
TRAP-TYPE    

ss7LinkRemInhNotify 65
Info : Link Inhibited Remotely
TRAP-TYPE    

ss7LinkRemUnInhNotify 66
Info : Link UnInhibited Remotely
TRAP-TYPE    

ss7LinkLocInhNotify 67
Info : Link Inhibited Locally
TRAP-TYPE    

ss7LinkLocUnInhNotify 68
Info : Link UnInhibited Locally
TRAP-TYPE    

ss7LinkLOPBlkNotify 69
Info : Local Processor Recovered causing link unblocked
TRAP-TYPE    

ss7LinkLPRNotify 70
Info : Local Processor Recovered causing link unblocked
TRAP-TYPE    

ss7LinkRPONotify 71
Info :LSSU/SIPO Received
TRAP-TYPE    

ss7LinkRPRNotify 72
Info :LSSU/SIPO stopped and FISU/MSU recived
TRAP-TYPE    

ss7IsupCicLocNotify 73
Info : ISUP Circuits are blocked/unblocked locally
TRAP-TYPE    

ss7IsupCicRemNotify 74
Info : ISUP Circuits are blocked/unblocked remotely
TRAP-TYPE    

ss7IsupCongLvl1Notify 75
Info : Route to DPC is encountering Level 1 Congestion
TRAP-TYPE    

ss7IsupCongLvl2Notify 76
Info : Route to DPC is encountering Level 2 Congestion
TRAP-TYPE    

isdnDChnlUpNotify 77
Info : An ISDN D-channel is Up
TRAP-TYPE    

isdnDChnlDnNotify 78
Info : An ISDN D-channel is down
TRAP-TYPE    

logFileReadyNotify 79
Info : Logger file is ready
TRAP-TYPE    

logDiskFull60PercentNotify 80
Info : Log Files occupy 60% of disk quota
TRAP-TYPE    

logDiskFull70PercentNotify 81
Info : Log Files occupy 70% of disk quota
TRAP-TYPE    

logDiskFull80PercentNotify 82
Info : Log Files occupy 80% of disk quota
TRAP-TYPE    

logErrFileOpenNotify 83
Info : Log file open error
TRAP-TYPE    

logErrFileCloseNotify 84
Info : Log file close error
TRAP-TYPE    

logErrFileDeleteNotify 85
Info : Log file cannot be deleted
TRAP-TYPE    

logErrFileWriteNotify 86
Info : Log manager cannot write to log file
TRAP-TYPE    

msscPriDedicatedLinkUpNotify 87
Info : Dedicated link between the 2 Netra machine is UP
TRAP-TYPE    

msscPriDedicatedLinkDownNotify 88
Info : Dedicated link between the 2 Netra machine is down
TRAP-TYPE    

msscSecDedicatedLinkUpNotify 89
Info : Dedicated link between the 2 Netra machine is UP
TRAP-TYPE    

msscSecDedicatedLinkDownNotify 90
Info :Dedicated link between the 2 Netra machine is down
TRAP-TYPE    

msscPriPsuUpNotify 91
Info : Primary hosts power supply up
TRAP-TYPE    

msscPriPsuDownNotify 92
Info : Primary hosts power supply down
TRAP-TYPE    

msscBakPsuUpNotify 93
Info : Backup hosts power supply up
TRAP-TYPE    

msscBakPsuDownNotify 94
Info : Backup hosts power supply down
TRAP-TYPE    

msscPriLanPhyIntfUpNotify 95
Info : Primary Physical LAN Interface Up
TRAP-TYPE    

msscPriLanPhyIntfDownNotify 96
Info : Primary Physical LAN Interface Down
TRAP-TYPE    

msscSecLanPhyIntfUpNotify 97
Info : Secondary physical LAN Interface Up
TRAP-TYPE    

msscSecLanPhyIntfDownNotify 98
Info : Secondary Physical LAN Interface Down
TRAP-TYPE    

msscPriHostFanUpNotify 99
Info : Primary Fan Up
TRAP-TYPE    

msscPriHostFanDownNotify 100
Info : Primary Fan Down
TRAP-TYPE    

msscBckHostFanUpNotify 101
Info : Backup Fan Up
TRAP-TYPE    

msscBckHostFanDownNotify 102
Info : Backup Fan Down
TRAP-TYPE    

hubPriIntfUpNotify 103
Info : Primary Interface Up
TRAP-TYPE    

hubPriIntfDownNotify 104
Info : Primary Interface down
TRAP-TYPE    

hubSecIntfUpNotify 105
Info : Secondary Interface Up
TRAP-TYPE    

hubSecIntfDownNotify 106
Info : Secondary Interface Down
TRAP-TYPE    

ftProcessAbnormalTerminationNotify 107
Info : Process abnormal termination
TRAP-TYPE    

ftProcessRestartConfigSucceededNotify 108
Info : Process abnormal termination
TRAP-TYPE    

ftProcessRestartConfigFailedNotify 109
Info : Process abnormal termination
TRAP-TYPE    

ftMsscFtmupNotify 110
Info : Process abnormal termination
TRAP-TYPE    

ftControlSwitchOverSucceededNotify 111
Info : Control SwitchOver Successful
TRAP-TYPE    

ftControlSwitchOverFailedNotify 112
Info : Control SwitchOver Failure
TRAP-TYPE    

ftForcedSwitchOverSucceededNotify 113
Info : Forced SwitchOver Successful
TRAP-TYPE    

ftForcedSwitchOverFailedNotify 114
Info : Forced SwitchOver Failure
TRAP-TYPE    

ftProcessRestartDisableNotify 115
Tok_String
TRAP-TYPE    

updateDBAuditOpStatNotify 116
Info : Updated the Database for Audited Related Operational Status
TRAP-TYPE    

isupIccAuditNotify 117
ISUP ICC Audit Notify
TRAP-TYPE    

cdrDiskFullMinorNotify 118
CDR Disk Usage reached Minor Threshold
TRAP-TYPE    

cdrDiskFullMajorNotify 119
CDR Disk Usage reached Major Threshold
TRAP-TYPE    

cdrErrMoveCdrNackNotify 120
Invalid CDR file Non-Ack Directory
TRAP-TYPE    

cdrFileMoveCdrNackNotify 121
CDR file moved to Non-Ack Directory
TRAP-TYPE    

ss7CktValidationNotify 122
Validation of Circuits
TRAP-TYPE    

switchActiveAlarmTable 1.3.6.1.4.1.4618.1.2.7.2.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SwitchActiveAlarmEntry

switchActiveAlarmEntry 1.3.6.1.4.1.4618.1.2.7.2.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SwitchActiveAlarmEntry  

switchAlarmMsgId 1.3.6.1.4.1.4618.1.2.7.2.2.1.1
Alarm Message Id. Can be any integer from 1-65535.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

switchAlarmInstNo 1.3.6.1.4.1.4618.1.2.7.2.2.1.2
Instance number related to alarm. Can be any integer from 1-65535.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

switchAlarmTime 1.3.6.1.4.1.4618.1.2.7.2.2.1.3
Date and time when the alarma was generated
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

switchAlarmType 1.3.6.1.4.1.4618.1.2.7.2.2.1.4
This specifies the event group is alarm. Default :ALARM
Status: mandatory Access: read-only
OBJECT-TYPE    
  EventType  

switchAlarmMainEvent 1.3.6.1.4.1.4618.1.2.7.2.2.1.5
This specifies the main event event group of alarm
Status: mandatory Access: read-only
OBJECT-TYPE    
  AlarmEvent  

switchAlarmSubEvent 1.3.6.1.4.1.4618.1.2.7.2.2.1.6
This specifies the main event event group of alarm
Status: mandatory Access: read-only
OBJECT-TYPE    
  AlarmSubEvent  

switchAlarmId 1.3.6.1.4.1.4618.1.2.7.2.2.1.7
This specifies the alarm that was sent
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

switchAlarmSeverity 1.3.6.1.4.1.4618.1.2.7.2.2.1.8
This field defines the severity of alarms of alarm. Alarms can od : Major,Minor,Critical and Informational
Status: mandatory Access: read-only
OBJECT-TYPE    
  AlarmSeverity  

switchAlarmDesc 1.3.6.1.4.1.4618.1.2.7.2.2.1.9
This description related to Generated alarm
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

switchAlarmAck 1.3.6.1.4.1.4618.1.2.7.2.2.1.10
This field is to acknowelge the alarms manually
Status: mandatory Access: read-write
OBJECT-TYPE    
  ActiveAlarmAckStatus  

switchAlarmRepeatTime 1.3.6.1.4.1.4618.1.2.7.2.2.1.11
Alarm Repeat Time in minutes: After the set time all alarms in the active alarm table will be displayed to the user again
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..60