ASCEND-MIBATMSIG-MIB

File: ASCEND-MIBATMSIG-MIB.mib (17033 bytes)

Imported modules

ASCEND-MIB RFC1155-SMI RFC-1212

Imported symbols

configuration IpAddress OBJECT-TYPE

Defined Types

DisplayString  
OCTET STRING    

MibatmIntfSigParamsEntry  
SEQUENCE    
  atmIntfSigParams-Shelf-o INTEGER
  atmIntfSigParams-Slot-o INTEGER
  atmIntfSigParams-Item-o INTEGER
  atmIntfSigParams-LogicalItem-o INTEGER
  atmIntfSigParams-Address-PhysicalAddress-Shelf INTEGER
  atmIntfSigParams-Address-PhysicalAddress-Slot INTEGER
  atmIntfSigParams-Address-PhysicalAddress-ItemNumber INTEGER
  atmIntfSigParams-Address-LogicalItem INTEGER
  atmIntfSigParams-Q2931Options-MaxRestart INTEGER
  atmIntfSigParams-Q2931Options-MaxStatenq INTEGER
  atmIntfSigParams-Q2931Options-T301Ms INTEGER
  atmIntfSigParams-Q2931Options-T303Ms INTEGER
  atmIntfSigParams-Q2931Options-T306Ms INTEGER
  atmIntfSigParams-Q2931Options-T308Ms INTEGER
  atmIntfSigParams-Q2931Options-T309Ms INTEGER
  atmIntfSigParams-Q2931Options-T310Ms INTEGER
  atmIntfSigParams-Q2931Options-T313Ms INTEGER
  atmIntfSigParams-Q2931Options-T316Ms INTEGER
  atmIntfSigParams-Q2931Options-T317Ms INTEGER
  atmIntfSigParams-Q2931Options-T322Ms INTEGER
  atmIntfSigParams-Q2931Options-T331Ms INTEGER
  atmIntfSigParams-Q2931Options-T333Ms INTEGER
  atmIntfSigParams-Q2931Options-T397Ms INTEGER
  atmIntfSigParams-Q2931Options-T398Ms INTEGER
  atmIntfSigParams-Q2931Options-T399Ms INTEGER
  atmIntfSigParams-Q2931Options-SaalRetryMs INTEGER
  atmIntfSigParams-Q2931Options-T303NumReties INTEGER
  atmIntfSigParams-Q2931Options-T308NumRetries INTEGER
  atmIntfSigParams-Q2931Options-T316NumRetries INTEGER
  atmIntfSigParams-Q2931Options-T322NumRetries INTEGER
  atmIntfSigParams-Q2931Options-T331NumRetries INTEGER
  atmIntfSigParams-Q2931Options-AssignVpiVci INTEGER
  atmIntfSigParams-QsaalOptions-WindowSize INTEGER
  atmIntfSigParams-QsaalOptions-MaxCc INTEGER
  atmIntfSigParams-QsaalOptions-MaxPd INTEGER
  atmIntfSigParams-QsaalOptions-MaxStat INTEGER
  atmIntfSigParams-QsaalOptions-TccMs INTEGER
  atmIntfSigParams-QsaalOptions-TpollMs INTEGER
  atmIntfSigParams-QsaalOptions-TkeepaliveMs INTEGER
  atmIntfSigParams-QsaalOptions-TnoresponseMs INTEGER
  atmIntfSigParams-QsaalOptions-TidleMs INTEGER
  atmIntfSigParams-QsaalOptions-PollAfterRetransmission INTEGER
  atmIntfSigParams-QsaalOptions-RepeatUstat INTEGER
  atmIntfSigParams-QsaalOptions-UstatRspToPoll INTEGER
  atmIntfSigParams-Action-o INTEGER

Defined Values

mibatmIntfSigParams 1.3.6.1.4.1.529.23.52
OBJECT IDENTIFIER    

mibatmIntfSigParamsTable 1.3.6.1.4.1.529.23.52.1
A list of mibatmIntfSigParams profile entries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MibatmIntfSigParamsEntry

mibatmIntfSigParamsEntry 1.3.6.1.4.1.529.23.52.1.1
A mibatmIntfSigParams entry containing objects that maps to the parameters of mibatmIntfSigParams profile.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MibatmIntfSigParamsEntry  

atmIntfSigParams-Shelf-o 1.3.6.1.4.1.529.23.52.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Slot-o 1.3.6.1.4.1.529.23.52.1.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Item-o 1.3.6.1.4.1.529.23.52.1.1.3
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-LogicalItem-o 1.3.6.1.4.1.529.23.52.1.1.4
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Address-PhysicalAddress-Shelf 1.3.6.1.4.1.529.23.52.1.1.5
The number of the shelf that the addressed physical device resides on.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER anyShelf(1), shelf1(2), shelf2(3), shelf3(4), shelf4(5), shelf5(6), shelf6(7), shelf7(8), shelf8(9), shelf9(10)  

atmIntfSigParams-Address-PhysicalAddress-Slot 1.3.6.1.4.1.529.23.52.1.1.6
The number of the slot that the addressed physical device resides on.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER anySlot(1), slot1(2), slot2(3), slot3(4), slot4(5), slot5(6), slot6(7), slot7(8), slot8(9), slot9(10), slot10(11), slot11(12), slot12(13), slot13(14), slot14(15), slot15(16), slot16(17), slot17(18), slot18(19), slot19(20), slot20(21), slot21(22), slot22(23), slot23(24), slot24(25), slot25(26), slot26(27), slot27(28), slot28(29), slot29(30), slot30(31), slot31(32), slot32(33), slot33(34), slot34(35), slot35(36), slot36(37), slot37(38), slot38(39), slot39(40), slot40(41), aLim(55), bLim(56), cLim(57), dLim(58), leftController(49), rightController(50), controller(42), firstControlModule(53), secondControlModule(54), trunkModule1(45), trunkModule2(46), controlModule(51), slotPrimary(59)  

atmIntfSigParams-Address-PhysicalAddress-ItemNumber 1.3.6.1.4.1.529.23.52.1.1.7
A number that specifies an addressable entity within the context of shelf and slot.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Address-LogicalItem 1.3.6.1.4.1.529.23.52.1.1.8
A number that specifies an addressable logical entity within the context of a physical address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-MaxRestart 1.3.6.1.4.1.529.23.52.1.1.9
Maximum number of unacknowledged tx RESTART.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-MaxStatenq 1.3.6.1.4.1.529.23.52.1.1.10
Maximum number of unacknowledged tx STATUS ENQ.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-T301Ms 1.3.6.1.4.1.529.23.52.1.1.11
Timer (in msec) for alerting supervision function. This timer is started on receipt of ALERT in Call received/delivered state and stopped when CONNECT is received.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-T303Ms 1.3.6.1.4.1.529.23.52.1.1.12
Timer (in msec) for a response after SETUP is sent. This timer is stopped when the CONNECT, CALL PROCEEDING, or RELEASE COMPLETE is received.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-T306Ms 1.3.6.1.4.1.529.23.52.1.1.13
Timer (in msec) for a RELEASE_COMPLETE to be received after a release has been sent.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-T308Ms 1.3.6.1.4.1.529.23.52.1.1.14
Timer (in msec) for a response after RELEASE is sent. This is a release indication timer. This timer is started when the RELEASE message is sent and normally is stopped when the RELEASE or RELEASE COMPLETE is received.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-T309Ms 1.3.6.1.4.1.529.23.52.1.1.15
Timer (in msec) for Q.SAAL to reconnect. After this time, calls are dropped. When set to 0, a default value based on an ATM signaling protocol will be used.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-T310Ms 1.3.6.1.4.1.529.23.52.1.1.16
Timer (in msec) for a response after SETUP is received. Also called the CALL PROCEEDING timer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-T313Ms 1.3.6.1.4.1.529.23.52.1.1.17
Timer (in msec) for a response after CONNECT is sent. Also called the connect request timer. It is started when the CONNECT is sent and stopped when the CONNECT ACKNOWLEDGE is recieved.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-T316Ms 1.3.6.1.4.1.529.23.52.1.1.18
Timer (in msec) for a response after RESTART is sent. Also called the restart request timer. It is started when the RESTART is sent and stopped when the RESTART ACKNOWLEDGE is recieved.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-T317Ms 1.3.6.1.4.1.529.23.52.1.1.19
Timer (in msec) for internal clearing of call references. This timer is started as a result of a restart and cleared when all the internal call references are cleared. Should be less than the the likely value of T316 of the peer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-T322Ms 1.3.6.1.4.1.529.23.52.1.1.20
Timer (in msec) for a response after STATUS ENQ is sent.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-T331Ms 1.3.6.1.4.1.529.23.52.1.1.21
Timer (in msec) for internal clearing of call references.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-T333Ms 1.3.6.1.4.1.529.23.52.1.1.22
Timer (in msec) for internal clearing of call references.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-T397Ms 1.3.6.1.4.1.529.23.52.1.1.23
Timer (in msec) for internal clearing of call references.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-T398Ms 1.3.6.1.4.1.529.23.52.1.1.24
Timer (in msec) for receipt of a response to a DROP PARTY that was sent.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-T399Ms 1.3.6.1.4.1.529.23.52.1.1.25
Timer (in msec) for receipt of a response to an ADD PARTY that was sent.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-SaalRetryMs 1.3.6.1.4.1.529.23.52.1.1.26
Timer value for retrying AAL_ESTABLISH messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-T303NumReties 1.3.6.1.4.1.529.23.52.1.1.27
Number of times SETUP could be resent in case of T303 timer expiry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-T308NumRetries 1.3.6.1.4.1.529.23.52.1.1.28
Number of times RELEASE could be sent in case of T308 timer expiry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-T316NumRetries 1.3.6.1.4.1.529.23.52.1.1.29
Number of times RESTART could be sent in case RESTART ACK is not received withinn T316 timer expiry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-T322NumRetries 1.3.6.1.4.1.529.23.52.1.1.30
Number of times STAT ENQ could be sent before a response is received within the T322 timer expiry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-T331NumRetries 1.3.6.1.4.1.529.23.52.1.1.31
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-AssignVpiVci 1.3.6.1.4.1.529.23.52.1.1.32
In the case of UNI4.0 and PNNI this parameter specifies who assigns the VPI/VCI. TRUE will allow the local stack and FALSE will let the partner stack to assign.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

atmIntfSigParams-QsaalOptions-WindowSize 1.3.6.1.4.1.529.23.52.1.1.33
Q.SAAL window size
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-QsaalOptions-MaxCc 1.3.6.1.4.1.529.23.52.1.1.34
Maximum number of control PDU (BGN, END, RESYNC) retransmissions.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-QsaalOptions-MaxPd 1.3.6.1.4.1.529.23.52.1.1.35
Maximum number of Sequenced data PDU's between poll.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-QsaalOptions-MaxStat 1.3.6.1.4.1.529.23.52.1.1.36
Maximum length of STAT PDU.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-QsaalOptions-TccMs 1.3.6.1.4.1.529.23.52.1.1.37
Retry time (in msec) for control PDU's(BGN, END, RESYNC).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-QsaalOptions-TpollMs 1.3.6.1.4.1.529.23.52.1.1.38
Poll sent (in msec) when active. When set to 0, a default value based on an ATM signaling protocol will be used.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-QsaalOptions-TkeepaliveMs 1.3.6.1.4.1.529.23.52.1.1.39
Poll sent (in msec) when in transient state. When set to 0, a default value based on an ATM signaling protocol will be used.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-QsaalOptions-TnoresponseMs 1.3.6.1.4.1.529.23.52.1.1.40
STAT received at least this period(in msec). When set to 0, a default value based on an ATM signaling protocol will be used.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-QsaalOptions-TidleMs 1.3.6.1.4.1.529.23.52.1.1.41
Poll sent (in msec) when idle -- UNI 3.1, only.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-QsaalOptions-PollAfterRetransmission 1.3.6.1.4.1.529.23.52.1.1.42
Specifies after retransmitting PDUs whether a POLL must be sent before sending any further PDUs.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

atmIntfSigParams-QsaalOptions-RepeatUstat 1.3.6.1.4.1.529.23.52.1.1.43
Specifies whether two USTAT messages should be sent each time it is required to be sent.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

atmIntfSigParams-QsaalOptions-UstatRspToPoll 1.3.6.1.4.1.529.23.52.1.1.44
Specifies whether a USTAT should be sent in response to a POLL indicating an out of sequence PDU.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

atmIntfSigParams-Action-o 1.3.6.1.4.1.529.23.52.1.1.45
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noAction(1), createProfile(2), deleteProfile(3)