ASCEND-MIBCLTMRSLT-MIB

File: ASCEND-MIBCLTMRSLT-MIB.mib (16437 bytes)

Imported modules

ASCEND-MIB RFC1155-SMI RFC-1212

Imported symbols

configuration IpAddress OBJECT-TYPE

Defined Types

DisplayString  
OCTET STRING    

MibcltmRsltEntry  
SEQUENCE    
  cltmRslt-Index-o INTEGER
  cltmRslt-CltmSlot INTEGER
  cltmRslt-TestResultTimeStamp INTEGER
  cltmRslt-TestResultSequence INTEGER
  cltmRslt-TestResultStatus INTEGER
  cltmRslt-DmmResult INTEGER
  cltmRslt-LoopResistance INTEGER
  cltmRslt-LoopResistanceLength1 INTEGER
  cltmRslt-LoopResistanceLength2 INTEGER
  cltmRslt-LoopResistanceLength3 INTEGER
  cltmRslt-CoilDetectionCoilCount INTEGER
  cltmRslt-ImpulseNoiseReadLowThreshold INTEGER
  cltmRslt-ImpulseNoiseReadMidThreshold INTEGER
  cltmRslt-ImpulseNoiseReadHighThreshold INTEGER
  cltmRslt-RcvToneFrequency INTEGER
  cltmRslt-RcvToneLevel INTEGER
  cltmRslt-TdrManualSampleCount INTEGER
  cltmRslt-TdrAutomaticFaultDistance INTEGER
  cltmRslt-HardwareRevision INTEGER
  cltmRslt-SofwareRevision INTEGER
  cltmRslt-DcDeltaResistanceTR INTEGER
  cltmRslt-DcDeltaResistanceTS INTEGER
  cltmRslt-DcDeltaResistanceRS INTEGER
  cltmRslt-DcDeltaVoltageTS INTEGER
  cltmRslt-DcDeltaVoltageRS INTEGER
  cltmRslt-CapEquivalentTR INTEGER
  cltmRslt-CapEquivalentTS INTEGER
  cltmRslt-CapEquivalentRS INTEGER
  cltmRslt-DmmAllTR INTEGER
  cltmRslt-DmmAllTS INTEGER
  cltmRslt-DmmAllRS INTEGER
  cltmRslt-Ringer INTEGER
  cltmRslt-AtuR INTEGER
  cltmRslt-BridgeTapNumber INTEGER
  cltmRslt-BridgeTapLength INTEGER
  cltmRslt-VoiceDetection INTEGER
  cltmRslt-FirstCoilLocation INTEGER
  cltmRslt-ShortLocation INTEGER
  cltmRslt-Action-o INTEGER

MibcltmRslt-BridgeTapTableEntry  
SEQUENCE    
  cltmRslt-BridgeTapTable-Index-o INTEGER
  cltmRslt-BridgeTapTable-Index1-o INTEGER
  cltmRslt-BridgeTapTable-Distance INTEGER
  cltmRslt-BridgeTapTable-Length INTEGER
  cltmRslt-BridgeTapTable-Confidence INTEGER

MibcltmRslt-TdrDistanceLevelEntry  
SEQUENCE    
  cltmRslt-TdrDistanceLevel-Index-o INTEGER
  cltmRslt-TdrDistanceLevel-Index1-o INTEGER
  cltmRslt-TdrDistanceLevel-Distance INTEGER
  cltmRslt-TdrDistanceLevel-Level INTEGER

MibcltmRslt-PsdFrequencyLevelEntry  
SEQUENCE    
  cltmRslt-PsdFrequencyLevel-Index-o INTEGER
  cltmRslt-PsdFrequencyLevel-Index1-o INTEGER
  cltmRslt-PsdFrequencyLevel-Frequency INTEGER
  cltmRslt-PsdFrequencyLevel-Level INTEGER

Defined Values

mibcltmRslt 1.3.6.1.4.1.529.23.68
OBJECT IDENTIFIER    

mibcltmRsltTable 1.3.6.1.4.1.529.23.68.1
A list of mibcltmRslt profile entries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MibcltmRsltEntry

mibcltmRsltEntry 1.3.6.1.4.1.529.23.68.1.1
A mibcltmRslt entry containing objects that maps to the parameters of mibcltmRslt profile.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MibcltmRsltEntry  

cltmRslt-Index-o 1.3.6.1.4.1.529.23.68.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-CltmSlot 1.3.6.1.4.1.529.23.68.1.1.2
Identify the CLTM slot within the system.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER anySlot(1), slot1(2), slot2(3), slot3(4), slot4(5), slot5(6), slot6(7), slot7(8), slot10(11), slot11(12), slot12(13), slot13(14), slot14(15), slot15(16), slot16(17)  

cltmRslt-TestResultTimeStamp 1.3.6.1.4.1.529.23.68.1.1.3
Value of the sysUpTime when the test result was obtained.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-TestResultSequence 1.3.6.1.4.1.529.23.68.1.1.4
Sequence of the last test result.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-TestResultStatus 1.3.6.1.4.1.529.23.68.1.1.5
This parameter indicates whether the test result is valid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notReady(1), notValid(2), overRange(3), valid(4)  

cltmRslt-DmmResult 1.3.6.1.4.1.529.23.68.1.1.6
DMM Measurement result. The units are Ohm for resistance, dc/av milli Volt for voltage and pico Farad for capacitance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-LoopResistance 1.3.6.1.4.1.529.23.68.1.1.7
Resistance in Kohm for Loop Resistance Test.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-LoopResistanceLength1 1.3.6.1.4.1.529.23.68.1.1.8
Length in feet of 22AWG or meter of 0.644mm for Loop Resistance Test.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-LoopResistanceLength2 1.3.6.1.4.1.529.23.68.1.1.9
Length in feet of 24AWG or meter of 0.511mm Loop Resistance Test.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-LoopResistanceLength3 1.3.6.1.4.1.529.23.68.1.1.10
Length in feet of 26AWG or meter of 0.405mm Loop Resistance Test.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-CoilDetectionCoilCount 1.3.6.1.4.1.529.23.68.1.1.11
Number of coil detected for Coil Detection Test.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-ImpulseNoiseReadLowThreshold 1.3.6.1.4.1.529.23.68.1.1.12
Impulse Read Counter over low Db threshold.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-ImpulseNoiseReadMidThreshold 1.3.6.1.4.1.529.23.68.1.1.13
Impulse Read Counter over mid Db threshold.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-ImpulseNoiseReadHighThreshold 1.3.6.1.4.1.529.23.68.1.1.14
Impulse Read Counter over high Db threshold.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-RcvToneFrequency 1.3.6.1.4.1.529.23.68.1.1.15
Receive Tone Frequency.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-RcvToneLevel 1.3.6.1.4.1.529.23.68.1.1.16
Receive Tone Level.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-TdrManualSampleCount 1.3.6.1.4.1.529.23.68.1.1.17
Number of detectde sample pairs via manual TDR test.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-TdrAutomaticFaultDistance 1.3.6.1.4.1.529.23.68.1.1.18
Distance of the detected fault via automatic TDR test.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-HardwareRevision 1.3.6.1.4.1.529.23.68.1.1.19
Hardware revision number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-SofwareRevision 1.3.6.1.4.1.529.23.68.1.1.20
Software revision number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-DcDeltaResistanceTR 1.3.6.1.4.1.529.23.68.1.1.21
dc delta resistance T-R.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-DcDeltaResistanceTS 1.3.6.1.4.1.529.23.68.1.1.22
dc delta resistance T-S.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-DcDeltaResistanceRS 1.3.6.1.4.1.529.23.68.1.1.23
dc delta resistance R-S.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-DcDeltaVoltageTS 1.3.6.1.4.1.529.23.68.1.1.24
dc delta voltage T-S.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-DcDeltaVoltageRS 1.3.6.1.4.1.529.23.68.1.1.25
dc delta voltage R-S.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-CapEquivalentTR 1.3.6.1.4.1.529.23.68.1.1.26
capacitance T-R.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-CapEquivalentTS 1.3.6.1.4.1.529.23.68.1.1.27
capacitance T-S.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-CapEquivalentRS 1.3.6.1.4.1.529.23.68.1.1.28
capacitance R-S.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-DmmAllTR 1.3.6.1.4.1.529.23.68.1.1.29
dmm all T-R.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-DmmAllTS 1.3.6.1.4.1.529.23.68.1.1.30
dmm all T-S.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-DmmAllRS 1.3.6.1.4.1.529.23.68.1.1.31
dmm all R-S.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-Ringer 1.3.6.1.4.1.529.23.68.1.1.32
detect ringer.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-AtuR 1.3.6.1.4.1.529.23.68.1.1.33
detect ATU-R.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-BridgeTapNumber 1.3.6.1.4.1.529.23.68.1.1.34
bridge-tap number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-BridgeTapLength 1.3.6.1.4.1.529.23.68.1.1.35
bridge-tap-loop-len.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-VoiceDetection 1.3.6.1.4.1.529.23.68.1.1.37
Voice Detection: 1: Voice signal not detected. 2: Voice signal detected. 3: Steady state - possible data traffic. 4: Interrupted tone detected - 60 or 120 IPM.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-FirstCoilLocation 1.3.6.1.4.1.529.23.68.1.1.38
First Coil Location in 0.01 feet or cm.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-ShortLocation 1.3.6.1.4.1.529.23.68.1.1.39
Short Location in 0.01 feet or cm.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-Action-o 1.3.6.1.4.1.529.23.68.1.1.36
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noAction(1), createProfile(2), deleteProfile(3)  

mibcltmRslt-BridgeTapTableTable 1.3.6.1.4.1.529.23.68.2
A list of mibcltmRslt__bridge_tap_table profile entries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MibcltmRslt-BridgeTapTableEntry

mibcltmRslt-BridgeTapTableEntry 1.3.6.1.4.1.529.23.68.2.1
A mibcltmRslt__bridge_tap_table entry containing objects that maps to the parameters of mibcltmRslt__bridge_tap_table profile.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MibcltmRslt-BridgeTapTableEntry  

cltmRslt-BridgeTapTable-Index-o 1.3.6.1.4.1.529.23.68.2.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-BridgeTapTable-Index1-o 1.3.6.1.4.1.529.23.68.2.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-BridgeTapTable-Distance 1.3.6.1.4.1.529.23.68.2.1.3
Bridge-Tap Distance in Feet or Meter
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-BridgeTapTable-Length 1.3.6.1.4.1.529.23.68.2.1.4
Bridge-Tap length(in Feet or Meter)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-BridgeTapTable-Confidence 1.3.6.1.4.1.529.23.68.2.1.5
confidence Level in percentage(33 or 55)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mibcltmRslt-TdrDistanceLevelTable 1.3.6.1.4.1.529.23.68.3
A list of mibcltmRslt__tdr_distance_level profile entries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MibcltmRslt-TdrDistanceLevelEntry

mibcltmRslt-TdrDistanceLevelEntry 1.3.6.1.4.1.529.23.68.3.1
A mibcltmRslt__tdr_distance_level entry containing objects that maps to the parameters of mibcltmRslt__tdr_distance_level profile.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MibcltmRslt-TdrDistanceLevelEntry  

cltmRslt-TdrDistanceLevel-Index-o 1.3.6.1.4.1.529.23.68.3.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-TdrDistanceLevel-Index1-o 1.3.6.1.4.1.529.23.68.3.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-TdrDistanceLevel-Distance 1.3.6.1.4.1.529.23.68.3.1.3
Distance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-TdrDistanceLevel-Level 1.3.6.1.4.1.529.23.68.3.1.4
Level.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mibcltmRslt-PsdFrequencyLevelTable 1.3.6.1.4.1.529.23.68.4
A list of mibcltmRslt__psd_frequency_level profile entries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MibcltmRslt-PsdFrequencyLevelEntry

mibcltmRslt-PsdFrequencyLevelEntry 1.3.6.1.4.1.529.23.68.4.1
A mibcltmRslt__psd_frequency_level entry containing objects that maps to the parameters of mibcltmRslt__psd_frequency_level profile.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MibcltmRslt-PsdFrequencyLevelEntry  

cltmRslt-PsdFrequencyLevel-Index-o 1.3.6.1.4.1.529.23.68.4.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-PsdFrequencyLevel-Index1-o 1.3.6.1.4.1.529.23.68.4.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-PsdFrequencyLevel-Frequency 1.3.6.1.4.1.529.23.68.4.1.3
Test frequency.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmRslt-PsdFrequencyLevel-Level 1.3.6.1.4.1.529.23.68.4.1.4
Db Level.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER