ASCEND-MIBSS7NMI-MIB

File: ASCEND-MIBSS7NMI-MIB.mib (15718 bytes)

Imported modules

ASCEND-MIB RFC1155-SMI RFC-1212

Imported symbols

configuration IpAddress OBJECT-TYPE

Defined Types

DisplayString  
OCTET STRING    

MibsS7ProfileEntry  
SEQUENCE    
  sS7Profile-Index-o INTEGER
  sS7Profile-Enabled INTEGER
  sS7Profile-ControlProtocol INTEGER
  sS7Profile-PrimaryIpAddress IpAddress
  sS7Profile-PrimaryTcpPort INTEGER
  sS7Profile-SecondaryIpAddress IpAddress
  sS7Profile-SecondaryTcpPort INTEGER
  sS7Profile-BayId DisplayString
  sS7Profile-SystemType DisplayString
  sS7Profile-TransportOptions-Type INTEGER
  sS7Profile-TransportOptions-DeviceId INTEGER
  sS7Profile-TransportOptions-T1Duration INTEGER
  sS7Profile-TransportOptions-T2Duration INTEGER
  sS7Profile-TransportOptions-T3Duration INTEGER
  sS7Profile-TransportOptions-WindowSize INTEGER
  sS7Profile-TransportOptions-AckThreshold INTEGER
  sS7Profile-TransportOptions-HeartBeat INTEGER
  sS7Profile-TransportOptions-Tos-Active INTEGER
  sS7Profile-TransportOptions-Tos-Precedence INTEGER
  sS7Profile-TransportOptions-Tos-TypeOfService INTEGER
  sS7Profile-TransportOptions-Tos-ApplyTo INTEGER
  sS7Profile-TransportOptions-Tos-MarkingType INTEGER
  sS7Profile-TransportOptions-Tos-Dscp DisplayString
  sS7Profile-UseSystemIpAddressAsSource INTEGER
  sS7Profile-IpdcSourceAdddress IpAddress
  sS7Profile-Vrouter DisplayString
  sS7Profile-CongestionControl-CongestionControlType INTEGER
  sS7Profile-CongestionControl-Cl1Level INTEGER
  sS7Profile-CongestionControl-Cl1Action INTEGER
  sS7Profile-CongestionControl-Cl2Level INTEGER
  sS7Profile-CongestionControl-Cl2Action INTEGER
  sS7Profile-SignalingHeartbeat-Enabled INTEGER
  sS7Profile-SignalingHeartbeat-Interval INTEGER
  sS7Profile-ResilienceOptions-Type INTEGER
  sS7Profile-ResilienceOptions-Duration INTEGER
  sS7Profile-PriTunnelingOptions-Enabled INTEGER
  sS7Profile-PriTunnelingOptions-Duration INTEGER
  sS7Profile-Action-o INTEGER

MibpRITunlStatProfileEntry  
SEQUENCE    
  pRITunlStatProfile-Index-o INTEGER
  pRITunlStatProfile-Action-o INTEGER

Defined Values

mibsS7Profile 1.23.121
OBJECT IDENTIFIER    

mibpRITunlStatProfile 1.23.158
OBJECT IDENTIFIER    

mibsS7ProfileTable 1.23.121.1
A list of mibsS7Profile profile entries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MibsS7ProfileEntry

mibsS7ProfileEntry 1.23.121.1.1
A mibsS7Profile entry containing objects that maps to the parameters of mibsS7Profile profile.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MibsS7ProfileEntry  

sS7Profile-Index-o 1.23.121.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sS7Profile-Enabled 1.23.121.1.1.2
When set to 'no', interface to the SS7 gateway is disabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

sS7Profile-ControlProtocol 1.23.121.1.1.3
Control protocol between the access server and the signaling gateway.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER asgcp(1), ipdc0X(2), q931Plus(3)  

sS7Profile-PrimaryIpAddress 1.23.121.1.1.4
IP address of the primary SS7 gateway.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

sS7Profile-PrimaryTcpPort 1.23.121.1.1.5
TCP port on primary SS7 gateway.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sS7Profile-SecondaryIpAddress 1.23.121.1.1.6
IP address of the secondary SS7 gateway.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

sS7Profile-SecondaryTcpPort 1.23.121.1.1.7
TCP port on the secondary SS7 gateway.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sS7Profile-BayId 1.23.121.1.1.8
Bay ID defines the bay this device belongs to. Used for registration purposes only. The content of this field is reported to the gateway during the device registration process.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

sS7Profile-SystemType 1.23.121.1.1.9
Model ID and/or type of equipment. Used for device registration only. Must be listed in the database on the Gateway.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

sS7Profile-TransportOptions-Type 1.23.121.1.1.10
The type of transport layer that is to be used
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ascend(1), tcpEncaps2(2)  

sS7Profile-TransportOptions-DeviceId 1.23.121.1.1.11
A code that uniquely identifies this device to the Gateway. If multiple remote access servers are configured to use the same signaling gateway, every one of those servers must be assigned an identifier that is unique within the group.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sS7Profile-TransportOptions-T1Duration 1.23.121.1.1.12
Value of the ACK delay timer in milliseconds. This timer specifies the maximum delay for an acknowledgement when an I-frame is received. Default value is 1000 (1 second). The value must be less than T2 on the peer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sS7Profile-TransportOptions-T2Duration 1.23.121.1.1.13
Value of the transmission timeout timer in milliseconds. This timer specifies how long this endpoint should wait for an acknowledgement. Default value is 3000 (3 seconds). The value must be greater than T1 on the peer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sS7Profile-TransportOptions-T3Duration 1.23.121.1.1.14
Value of the persistent error timer in milliseconds. This timer specifies the maximum duration of attempts to re-establish a link before the transport layer flushes the data queues and sends an error indication up. Default value is 30000 (30 seconds).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sS7Profile-TransportOptions-WindowSize 1.23.121.1.1.15
Maximum number of sequentially numbered data packets that can be sent while pending acknowledgement at any given time. Default value is 7.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sS7Profile-TransportOptions-AckThreshold 1.23.121.1.1.16
The threshold for triggering an acknowledgement while receiving data packets. As soon as the specified number of packets is received, an ACK is sent back regardless of the value of T1 timer. The value of this parameter may not be greater than the window size. Default value is 6.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sS7Profile-TransportOptions-HeartBeat 1.23.121.1.1.17
When set to 'no', layer 2 heartbeat mechanism is not enabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

sS7Profile-TransportOptions-Tos-Active 1.23.121.1.1.34
Activate type of service for this connection.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

sS7Profile-TransportOptions-Tos-Precedence 1.23.121.1.1.35
Tag the precedence bits (priority bits) in the TOS octet of IP datagram header with this value when match occurs.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER n-000(1), n-001(33), n-010(65), n-011(97), n-100(129), n-101(161), n-110(193), n-111(225)  

sS7Profile-TransportOptions-Tos-TypeOfService 1.23.121.1.1.36
Tag the type of service field in the TOS octet of IP datagram header with this value when match occurs.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), cost(3), reliability(5), throughput(9), latency(17)  

sS7Profile-TransportOptions-Tos-ApplyTo 1.23.121.1.1.37
Define how the type-of-service applies to data flow for this connection.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER incoming(1025), outgoing(2049), both(3073)  

sS7Profile-TransportOptions-Tos-MarkingType 1.23.121.1.1.38
Select type of packet marking.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER precedenceTos(1), dscp(2)  

sS7Profile-TransportOptions-Tos-Dscp 1.23.121.1.1.39
DSCP tag to be used in marking of the packets (if marking-type = dscp).
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

sS7Profile-UseSystemIpAddressAsSource 1.23.121.1.1.18
When set to 'yes', use configured System IP Address as source ip address. When set to 'no', use IP Address of outgoing interface as source ip address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

sS7Profile-IpdcSourceAdddress 1.23.121.1.1.32
IP address to be used on the private network
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

sS7Profile-Vrouter 1.23.121.1.1.33
Specifies the virtual router to be used.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

sS7Profile-CongestionControl-CongestionControlType 1.23.121.1.1.19
Type of the congestion control algorithm to use.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), l3QueueDepth(2)  

sS7Profile-CongestionControl-Cl1Level 1.23.121.1.1.20
The level at which 'congestion level 1' indication will be issued. The value is interpreted according to the configured congestion control 'type'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sS7Profile-CongestionControl-Cl1Action 1.23.121.1.1.21
Action taken when congestion level 1 (defined by the value of cl1-level) is reached.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ignore(1), sendInfoToMgc(2)  

sS7Profile-CongestionControl-Cl2Level 1.23.121.1.1.22
The level at which 'congestion level 2' indication will be issued. The value is interpreted according to the configured congestion control 'type'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sS7Profile-CongestionControl-Cl2Action 1.23.121.1.1.23
Action taken when congestion level 2 (defined by the value of cl2-level) is reached.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ignore(1), sendInfoToMgc(2), rejectNewCall(3)  

sS7Profile-SignalingHeartbeat-Enabled 1.23.121.1.1.24
When set to yes, TNT will generate signaling heartbeat to MGC based on the interval configured in signaling-heartbeat interval.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

sS7Profile-SignalingHeartbeat-Interval 1.23.121.1.1.25
The time interval in seconds for layer 3 heartbeat messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sS7Profile-ResilienceOptions-Type 1.23.121.1.1.27
The type of resilience action required when line state changes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER releaseAll(1), maintainActive(2), timedRelease(3)  

sS7Profile-ResilienceOptions-Duration 1.23.121.1.1.28
The duration in milli seconds for which calls should be maintained when line state changes. Valid only if the type is configured as timed-release.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sS7Profile-PriTunnelingOptions-Enabled 1.23.121.1.1.29
When set to yes, we will synchronize the d-channel status with the IPDC signaling link state.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

sS7Profile-PriTunnelingOptions-Duration 1.23.121.1.1.30
The duration in milliseconds after which bringing down D-channel of tunneled-pri-signaling lines will be initiated.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sS7Profile-Action-o 1.23.121.1.1.26
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noAction(1), createProfile(2), deleteProfile(3)  

mibpRITunlStatProfileTable 1.23.158.1
A list of mibpRITunlStatProfile profile entries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MibpRITunlStatProfileEntry

mibpRITunlStatProfileEntry 1.23.158.1.1
A mibpRITunlStatProfile entry containing objects that maps to the parameters of mibpRITunlStatProfile profile.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MibpRITunlStatProfileEntry  

pRITunlStatProfile-Index-o 1.23.158.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

pRITunlStatProfile-Action-o 1.23.158.1.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noAction(1), createProfile(2), deleteProfile(3)