ATM-SWITCHING-NODE-MIB

File: ATM-SWITCHING-NODE-MIB.mib (105021 bytes)

Imported modules

RFC1155-SMI SNMPv2-TC RFC-1212

Imported symbols

Counter Gauge IpAddress
DisplayString enterprises TimeTicks
DisplayString OBJECT-TYPE

Defined Types

DateAndTime  
OCTET STRING Size(8)    

RowStatus  
INTEGER active(1), notInService(2), notReady(3), createAndGo(4), createAndWait(5), destroy(6)    

IfIndex  
INTEGER 0..65535    

NetPrefix  
OCTET STRING Size(0..13)    

AtmAddress  
OCTET STRING Size(0..20)    

SwitchEntry  
SEQUENCE    
  switchSlotIndex INTEGER
  switchAdminState INTEGER
  switchOperState INTEGER

ModuleEntry  
SEQUENCE    
  moduleSlotIndex INTEGER
  moduleType INTEGER
  moduleDescription DisplayString
  moduleSerialNumber DisplayString
  moduleSoftwareVersion INTEGER
  moduleHardwareVersion INTEGER
  moduleAdminState INTEGER
  moduleOperState INTEGER
  moduleErrors Counter
  moduleMaxVpc INTEGER
  moduleUsedVpc INTEGER
  moduleMaxVcc INTEGER
  moduleUsedVcc INTEGER

PortEntry  
SEQUENCE    
  portSlotIndex INTEGER
  portIndex INTEGER
  portInterface IfIndex

InterfaceEntry  
SEQUENCE    
  interfaceIndex IfIndex
  interfaceSlot INTEGER
  interfacePort INTEGER
  interfaceConnector INTEGER
  interfaceAdminState INTEGER
  interfaceOperState INTEGER
  interfaceAtmAccess INTEGER
  interfaceMediaType INTEGER
  interfaceMediaSpeed INTEGER
  interfaceMediaErrors Counter
  interfaceSubSlot INTEGER
  interfaceClocking INTEGER
  interfaceScrambling INTEGER
  interfaceAvailableBandwidth INTEGER
  interfaceAllocatedBandwidth INTEGER

VcXConnectEntry  
SEQUENCE    
  vcXInIndex IfIndex
  vcXInVpi INTEGER
  vcXInVci INTEGER
  vcXOutIndex IfIndex
  vcXOutVpi INTEGER
  vcXOutVci INTEGER
  vcXType INTEGER
  vcXDirection INTEGER

VpXConnectEntry  
SEQUENCE    
  vpXInIndex IfIndex
  vpXInVpi INTEGER
  vpXOutIndex IfIndex
  vpXOutVpi INTEGER
  vpXType INTEGER
  vpXDirection INTEGER

NbrEntry  
SEQUENCE    
  localIndex IfIndex
  nbrIpAddress1 IpAddress
  nbrIpAddress2 IpAddress
  nbrAtmAddress AtmAddress
  nbrIndex IfIndex
  nbrDescriptor DisplayString
  nbrOid OBJECT IDENTIFIER
  nbrName DisplayString
  nbrLocation DisplayString
  trunkId INTEGER

AtmQ2931ConfEntry  
SEQUENCE    
  atmQ2931ConfIndex IfIndex
  atmQ2931SiVpi INTEGER
  atmQ2931SiVci INTEGER
  atmQ2931T303 INTEGER
  atmQ2931T308 INTEGER
  atmQ2931T309 INTEGER
  atmQ2931T310 INTEGER
  atmQ2931T316 INTEGER
  atmQ2931T317 INTEGER
  atmQ2931T322 INTEGER
  atmQ2931T398 INTEGER
  atmQ2931T399 INTEGER
  atmQ2931SetupRetry INTEGER
  atmQ2931ReleaseRetry INTEGER
  atmQ2931RestartRetry INTEGER
  atmQ2931StatusRetry INTEGER

AtmQ2931StatsEntry  
SEQUENCE    
  atmQ2931StatsIndex IfIndex
  atmQ2931StatsVpi INTEGER
  atmQ2931StatsVci INTEGER
  atmQ2931OutCallAttempts Counter
  atmQ2931OutCallInProgress Gauge
  atmQ2931OutCallFailures Counter
  atmQ2931InCallAttempts Counter
  atmQ2931InCallInProgess Gauge
  atmQ2931InCallFailures Counter

AtmSvcEntry  
SEQUENCE    
  atmSvcInterfaceIndex IfIndex
  atmSvcSiVpi INTEGER
  atmSvcSiVci INTEGER
  atmSvcCallReference INTEGER
  atmSvcEndPointReference INTEGER
  atmSvcCallingNumber AtmAddress
  atmSvcCalledNumber AtmAddress
  atmSvcClear INTEGER
  atmSvcCreationTime DateAndTime
  atmSvcVpi INTEGER
  atmSvcVci INTEGER

AtmSvcLogEntry  
SEQUENCE    
  atmSvcLogIndex INTEGER
  atmSvcLogInterfaceIndex IfIndex
  atmSvcLogCallingNumber AtmAddress
  atmSvcLogCalledNumber AtmAddress
  atmSvcLogCreationTime DateAndTime
  atmSvcLogTime DateAndTime
  atmSvcLogClearCause INTEGER
  atmSvcLogForwardQOS INTEGER
  atmSvcLogBackwardQOS INTEGER
  atmSvcLogForwardBW INTEGER
  atmSvcLogBackwardBW INTEGER

AtmSaalConfEntry  
SEQUENCE    
  atmSaalConfIndex IfIndex
  atmSaalConfSiVpi INTEGER
  atmSaalConfSiVci INTEGER
  atmSaalState INTEGER
  atmSaalTimerPoll INTEGER
  atmSaalTimerKeepAlive INTEGER
  atmSaalTimerNoResponse INTEGER
  atmSaalTimerCC INTEGER
  atmSaalTimerIdle INTEGER
  atmSaalMaxCC INTEGER
  atmSaalMaxPD INTEGER
  atmSaalMaxStat INTEGER

AtmSaalStatsEntry  
SEQUENCE    
  atmSaalStatsIndex IfIndex
  atmSaalStatsSiVpi INTEGER
  atmSaalStatsSiVci INTEGER
  atmSaalUnexpectPdus Counter
  atmSaalUnsuccessPdus Counter
  atmSaalFailedEstablishment Counter
  atmSaalSequenceGap Counter
  atmSaalGapNumbers Counter
  atmSaalOtherListErrors Counter
  atmSaalLackOfCredit Counter
  atmSaalCreditObtained Counter

AtmPvcEntry  
SEQUENCE    
  atmPvcIndex IfIndex
  atmPvcIdentifier INTEGER
  atmPvcRowStatus RowStatus
  atmPvcType INTEGER
  atmPvcEndPoint INTEGER
  atmPvcVpi INTEGER
  atmPvcVci INTEGER
  atmPvcBackwardQos INTEGER
  atmPvcForwardQos INTEGER
  atmPvcBackwardType INTEGER
  atmPvcForwardType INTEGER
  atmPvcBackwardParm1 INTEGER
  atmPvcForwardParm1 INTEGER

AtmPvcEpEntry  
SEQUENCE    
  atmPvcEpIndex IfIndex
  atmPvcEpIdentifier INTEGER
  atmPvcEpParty INTEGER
  atmPvcEpRowStatus RowStatus
  atmPvcEpStatusCause INTEGER
  atmPvcEpRemAddress NetPrefix
  atmPvcEpRemIndex IfIndex
  atmPvcEpRemVpi INTEGER
  atmPvcEpRemVci INTEGER
  atmPvcEpLastActive DateAndTime
  atmPvcEpQ2931Cause INTEGER
  atmPvcEpFailures Counter

Defined Values

ibm 1.3.6.1.4.1.2
OBJECT IDENTIFIER    

ibmProd 1.3.6.1.4.1.2.6
OBJECT IDENTIFIER    

atmSw 1.3.6.1.4.1.2.6.33
OBJECT IDENTIFIER    

node 1.3.6.1.4.1.2.6.33.1
OBJECT IDENTIFIER    

agents 1.3.6.1.4.1.2.6.33.2
OBJECT IDENTIFIER    

ibm8260 1.3.6.1.4.1.2.6.33.2.1
OBJECT IDENTIFIER    

gatwick 1.3.6.1.4.1.2.6.33.2.2
OBJECT IDENTIFIER    

admin 1.3.6.1.4.1.2.6.33.3
OBJECT IDENTIFIER    

testType 1.3.6.1.4.1.2.6.33.3.1
OBJECT IDENTIFIER    

internalLoopback 1.3.6.1.4.1.2.6.33.3.1.1
OBJECT IDENTIFIER    

externalLoopback 1.3.6.1.4.1.2.6.33.3.1.2
OBJECT IDENTIFIER    

base 1.3.6.1.4.1.2.6.33.1.1
OBJECT IDENTIFIER    

dateTime 1.3.6.1.4.1.2.6.33.1.1.1
The local date and time in the ATM agent.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DateAndTime  

lastChange 1.3.6.1.4.1.2.6.33.1.1.2
The date and time of the last major change detected: - date and time reset - agent IP address(es), subnet mask(s), default gateway changed - LAN Emulation or IP ARP server address(es) changed - system parameters (name, contact, location) changed - module Changed -- module added/removed -- administrative State changed (isolate/attached) - interface changed: -- administrative State changed (enabled/disabled) -- operational state changed This variable is updated in relation with the following traps: - hello trap - change trap - linkUp/linkDown traps.
Status: deprecated Access: read-only
OBJECT-TYPE    
  DateAndTime  

lock 1.3.6.1.4.1.2.6.33.1.1.3
The purpose of this variable is to protect the path between the hub and the network management station. When set to secure (1), it is not possible to: - disable a port: -- if the SNMP request was received on this port -- if a LAN Emulation or an IP ARP server is on this port - isolate a module: -- if the SNMP request was received on this port -- if a LAN Emulation or an IP ARP server is on this port When set to unlock (2), the parameters referenced above can be modified for a limited time (30 seconds). When set to disabled (3), no protection is provided. Trying to modify one of these parameters results in a genErr error code in the Get-Response and a trap is returned to the agent.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER secured(1), unlock(2), disabled(3)  

ipArpServerAtmAddress 1.3.6.1.4.1.2.6.33.1.1.4
The ATM address of the ARP server used when communicating with the switch agent using Classical IP over ATM (RFC 1577).
Status: mandatory Access: read-write
OBJECT-TYPE    
  AtmAddress  

systemState 1.3.6.1.4.1.2.6.33.1.1.6
The state of the ATM subsystem. Setting this variable to reset, causes a reset of all the ATM modules. When the active switch is in slots 9/10, switch-a is returned. When the active switch is in slots 11/12, switch-b is returned.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER reset(1), switch-a(2), switch-b(3)  

traps 1.3.6.1.4.1.2.6.33.1.2
OBJECT IDENTIFIER    

hello 1.3.6.1.4.1.2.6.33.1.2.1
When disabled, the hello trap is neither sent. When enabled, the hello trap can be sent by the agent when the appropriate trap condition is detected.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

physical 1.3.6.1.4.1.2.6.33.1.3
OBJECT IDENTIFIER    

switchTable 1.3.6.1.4.1.2.6.33.1.3.1
This table controls slot attachement to the ATM switch. An ATM module is operational only when inserted in a slot which is defined as attached to the switch.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SwitchEntry

switchEntry 1.3.6.1.4.1.2.6.33.1.3.1.1
Entries of switchTable. Each entry corresponds to a slot that is physically wired to the switch. These slots may be attached to or isolated from the ATM switch.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SwitchEntry  

switchSlotIndex 1.3.6.1.4.1.2.6.33.1.3.1.1.1
A slot number controlled by the switch.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..64  

switchAdminState 1.3.6.1.4.1.2.6.33.1.3.1.1.2
The desired state of the slot connection to the switch. When a slot is isolated from the switch, the switch traffic from this slot to the switch is disabled. As a result, if an ATM module is plugged in this slot, it will not be operational. When a slot is attached to the switch, the switch is ready to receive ATM traffic from this slot. As a result, if an ATM module is plugged in this slot, it can be used for ATM traffic.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER isolate(1), attach(2)  

switchOperState 1.3.6.1.4.1.2.6.33.1.3.1.1.3
The actual state of the slot connection to the switch. When the administrative state is set to ISOLATE, the operational state becomes ISOLATED. When the operational state is set to ATTACH, the operational state may become either ATTACHED or ISOLATED depending on the hardware current status of the slot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(1), attached(2)  

moduleTable 1.3.6.1.4.1.2.6.33.1.3.2
This table provides the list of ATM modules in the hub.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ModuleEntry

moduleEntry 1.3.6.1.4.1.2.6.33.1.3.2.1
Entries of moduleTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ModuleEntry  

moduleSlotIndex 1.3.6.1.4.1.2.6.33.1.3.2.1.1
The slot number for this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..64  

moduleType 1.3.6.1.4.1.2.6.33.1.3.2.1.2
The type of module attached to the ATM switch in this slot. The 'unknown' value is used when the ATM agent is unable to get information for this module (the module is isolated from the switch or is not operational).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), switch(2), atm-100-Mbps(3), atm-155-Mbps-2-ports-LAN(4)  

moduleDescription 1.3.6.1.4.1.2.6.33.1.3.2.1.3
A textual description of this module. This description is blank when no description is available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

moduleSerialNumber 1.3.6.1.4.1.2.6.33.1.3.2.1.4
The serial number for this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..13)  

moduleSoftwareVersion 1.3.6.1.4.1.2.6.33.1.3.2.1.5
The version and release number for this module firmware (microcode).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

moduleHardwareVersion 1.3.6.1.4.1.2.6.33.1.3.2.1.6
The Part Number (P/N) and Engineering Change (EC) level for this module and Plant Location.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

moduleAdminState 1.3.6.1.4.1.2.6.33.1.3.2.1.7
The administrative state of this module.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ready(1), reset(2)  

moduleOperState 1.3.6.1.4.1.2.6.33.1.3.2.1.8
The operational test of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), operational(2), not-operational(3)  

moduleErrors 1.3.6.1.4.1.2.6.33.1.3.2.1.9
The number of errors detected by this module on the traffic from the switch to this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

moduleMaxVpc 1.3.6.1.4.1.2.6.33.1.3.2.1.10
The maximum number of VPC supported by this module. The current number of VPC that can be used is the difference between moduleMaxVpc and moduleUsedVpc.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

moduleUsedVpc 1.3.6.1.4.1.2.6.33.1.3.2.1.11
The number of VPCs currently in use for this module. The current number of VPCs that can be used is the difference between moduleMaxVpc and moduleUsedVpc.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

moduleMaxVcc 1.3.6.1.4.1.2.6.33.1.3.2.1.12
The maximum number of VCCs supported by this module. The current number of VCCs that can be used is the difference between moduleMaxVcc and moduleUsedVcc.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

moduleUsedVcc 1.3.6.1.4.1.2.6.33.1.3.2.1.13
The number of VCC currently in use for this module. The current number of VCC that can be used is the difference between moduleMaxVcc and moduleUsedVcc.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

portTable 1.3.6.1.4.1.2.6.33.1.3.3
This table provides the list of ports attached to the ATM switch (ATM ports). These ports belong to ATM modules inserted in slots that are attached to the ATM switch.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PortEntry

portEntry 1.3.6.1.4.1.2.6.33.1.3.3.1
Entries of portTable. Each entry corresponds to a port that belongs to an ATM module. This module must be inserted in a slot that is attached to the ATM switch.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PortEntry  

portSlotIndex 1.3.6.1.4.1.2.6.33.1.3.3.1.1
The slot number of this port's module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..64  

portIndex 1.3.6.1.4.1.2.6.33.1.3.3.1.2
The port number for this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..64  

portInterface 1.3.6.1.4.1.2.6.33.1.3.3.1.3
The interface number of this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IfIndex  

interfaceTable 1.3.6.1.4.1.2.6.33.1.3.4
For each ATM port, this table maps the MIB-II interface index for this port with its physical slot and port numbers.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    InterfaceEntry

interfaceEntry 1.3.6.1.4.1.2.6.33.1.3.4.1
Entries of the interfaceTable. Each entry corresponds to a port that belongs to an ATM module. This module must be inserted in a slot that is attached to the ATM switch.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  InterfaceEntry  

interfaceIndex 1.3.6.1.4.1.2.6.33.1.3.4.1.1
The interface number of the port represented by this entry. This is the same number as the index used to represent this interface in the MIB-II interface table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IfIndex  

interfaceSlot 1.3.6.1.4.1.2.6.33.1.3.4.1.2
The slot number of this ATM port's module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..64  

interfacePort 1.3.6.1.4.1.2.6.33.1.3.4.1.3
The port number of this ATM port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..64  

interfaceConnector 1.3.6.1.4.1.2.6.33.1.3.4.1.4
Whether this port is an internal port (on the backplane) or an external connector.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), internal(2), mic(3), sc-Duplex(4), monomode(5), db-9(6), rj45(7)  

interfaceAdminState 1.3.6.1.4.1.2.6.33.1.3.4.1.5
The administrative state for this port. When set to disabled, no ATM traffic can pass on this port; all connections (SVC and PVC) are cleared. When set to wrap-reply, this interface is wrapped so that all the traffic received from the attached line is sent back on this line. If the interface state is not changed, it will automatically go back to the disabled state after one minute.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), wrap-reply(3)  

interfaceOperState 1.3.6.1.4.1.2.6.33.1.3.4.1.6
The operational state for this port: - unknown: the status of this port is unknown (this can be the result of a module in error) - disabled-nosignal: no activity is detected at the physical layer while the port is enabled - disabled-idle:: activity from the remote device attached to this port has been detected by the physical layer. The port is disabled. - failing: an internal hard error has been detected on this port while the port is enabled - no signal: no activity is detected at the physical layer while the port is enabled - idle: activity from the remote device attached to this port has been detected by the physical layer. The port is enabled. - in-service: the remote device successfully acknowledges ILMI polling requests and SVC registration - pvcOnly: the remote device succesfully acknowledges ILMI polling requests but it rejects the ATM prefix registration. Only PVCs are supported. - misConfigured: an SSI to UNI or an SSI to NNI configuration has been detected - wrongNetworkPrefix: the switches on each end of an SSI link have incompatible network prefixes (the 12 first bytes have different values) - wrongNodeNumber: the switches on each end of an SSI link have the same ATM node Numbers. - failing-line: the port is enabled and a invalid signal is detected on the line - disabled-failing: the port is disabled and an anomaly is detected, either internal or external. - wrap-no-signal: the port is internally wrapped so that all the traffic received on the attached line is returned unchanged on the line. No activity is detected at the physical layer. - wrap-idle: the port is internally wrapped so that all the traffic received on the attached line is returned unchanged on the line and a valid signal is detected on the line. - wrap-failing-internal: an internal failure has been detected when the port has been turned into the wrap-reply state. The actual state of the port is undefined. - wrap-failing-line: the port is internally wrapped so that all the traffic received on the attached line is returned unchanged on the line and an invalid signal is detected on the line. When disabled, the port may be in only one of the following states: - unknown, disabled-failing, disabled-nosignal or disabled-idle.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), disabled-nosignal(2), disabled-idle(3), no-signal(4), idle(5), in-service(6), pvcOnly(7), failing-internal(8), misConfigured(9), wrongNetworkPrefix(10), wrongNodeNumber(11), disabled-failing(12), failing-line(13), wrap-no-signal(14), wrap-idle(15), wrap-failing-internal(16), wrap-failing-line(17)  

interfaceAtmAccess 1.3.6.1.4.1.2.6.33.1.3.4.1.7
The type of ATM access offered on this port: - UNI: User Network Interface - SSI: Switch-to-Switch interface - NNI: Network-to-Network interface
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), uni(2), ssi(3), nni(4)  

interfaceMediaType 1.3.6.1.4.1.2.6.33.1.3.4.1.8
The type of cable attached to this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), monomode-fiber(2), multimode-fiber(3), twistedPair(4), utp(5), stp(6)  

interfaceMediaSpeed 1.3.6.1.4.1.2.6.33.1.3.4.1.9
The speed of this interface, in bits per second.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

interfaceMediaErrors 1.3.6.1.4.1.2.6.33.1.3.4.1.10
The number of physical layer errors detected on this media such as violation errors and length errors.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

interfaceSubSlot 1.3.6.1.4.1.2.6.33.1.3.4.1.11
When set to 0, this interface (and its physical connector) is directly located on the module identified by the slot number. When set to a non-zero value, this number identifies a feature card of the module that is used by this interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

interfaceClocking 1.3.6.1.4.1.2.6.33.1.3.4.1.12
The source of the bit clock used for data transmission. When set to external, the source is the clock received from the line.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER internal(1), external(2)  

interfaceScrambling 1.3.6.1.4.1.2.6.33.1.3.4.1.13
Whether data scrambling is used when transmitting on this line. Scrambling may be applied at the cell level, at the frame level or at cell and frame level.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), cell(2), frame(3), cell-and-frame(4)  

interfaceAvailableBandwidth 1.3.6.1.4.1.2.6.33.1.3.4.1.14
For a UNI or a NNI port: the current bandwidth available for the reserved bandwidth connections on this port. For a SSI port: the current bandwidth available on this port. It is in bits per second.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

interfaceAllocatedBandwidth 1.3.6.1.4.1.2.6.33.1.3.4.1.15
For a UNI or a NNI port: the bandwidth, in bits per second, currently used by the reserved bandwidth connections on this port. For a SSI port: the bandwidth, in bits per second, currently reserved on this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

switchStats 1.3.6.1.4.1.2.6.33.1.3.5
OBJECT IDENTIFIER    

switchMonitoring 1.3.6.1.4.1.2.6.33.1.3.5.1
When on, the switch throughput is monitored. When off, the switch thoughput is not monitored. Note that the monitoring decreases the system overall performances.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2)  

switchAggregateOutCells 1.3.6.1.4.1.2.6.33.1.3.5.2
The total number of cells transmitted from the switch. Note that this value is the aggregate throughput of all the ports on several minutes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

receiveTopList 1.3.6.1.4.1.2.6.33.1.3.5.3
The ifindexes of the five most receiving interfaces. The first ifindex given is the one corresponding to the interface which has received the more cells during the last polling interval. All ifIndexes are separated by a blank character. If there are less than 5 interfaces receiving data, there are less than 5 ifindexes listed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

transmitTopList 1.3.6.1.4.1.2.6.33.1.3.5.4
The ifindexes of the five most transmitting interfaces. The first ifindex given is the one corresponding to the interface which has sent the more cells during the last polling interval. All ifIndexes are separated by a blank character. If there are less than 5 interfaces transmitting data, there are less than 5 ifindexes listed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

connections 1.3.6.1.4.1.2.6.33.1.4
OBJECT IDENTIFIER    

vcXConnectTable 1.3.6.1.4.1.2.6.33.1.4.1
This table contains the cross-connections set-up in the switch for all existing VCL-based PVCs and SVCs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VcXConnectEntry

vcXConnectEntry 1.3.6.1.4.1.2.6.33.1.4.1.1
Entries of vcXConnectTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VcXConnectEntry  

vcXInIndex 1.3.6.1.4.1.2.6.33.1.4.1.1.1
The interface number for this ATM port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IfIndex  

vcXInVpi 1.3.6.1.4.1.2.6.33.1.4.1.1.2
The VPI value for this connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

vcXInVci 1.3.6.1.4.1.2.6.33.1.4.1.1.3
The VCI value for this connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

vcXOutIndex 1.3.6.1.4.1.2.6.33.1.4.1.1.4
The interface number for this ATM port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IfIndex  

vcXOutVpi 1.3.6.1.4.1.2.6.33.1.4.1.1.5
The VPI value for this connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

vcXOutVci 1.3.6.1.4.1.2.6.33.1.4.1.1.6
The VCI value for this connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

vcXType 1.3.6.1.4.1.2.6.33.1.4.1.1.7
Whether this cross-connection is part of a unicast or a multicast connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unicast(1), multicast(2)  

vcXDirection 1.3.6.1.4.1.2.6.33.1.4.1.1.8
Whether this entry identifies this cross-connection in the upstream or downstream flow, as seen from the root. Downstream means that the connection was set up from the in parameters (interface, VPI, VCI) to the out parameters (interface, VPI, VCI). In particular, for a multicast SVC, this means that the call initiator (the root in this case) is on the interface side labeled vcXInIndex. Upstream means that the connection was set up from the out parameters (interface, VPI, VCI) to the in parameters (interface, VPI, VCI). As a result, any cross-connection is modeled in this table as two entries, depending on whether it is seen in the up or down stream.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER upstream(1), downstream(2)  

vpXConnectTable 1.3.6.1.4.1.2.6.33.1.4.2
This table contains the cross-connections set-up in the switch for all existing VPL-based PVCs and SVCs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VpXConnectEntry

vpXConnectEntry 1.3.6.1.4.1.2.6.33.1.4.2.1
Entries of vpXConnectTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  VpXConnectEntry  

vpXInIndex 1.3.6.1.4.1.2.6.33.1.4.2.1.1
The interface number for this ATM port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IfIndex  

vpXInVpi 1.3.6.1.4.1.2.6.33.1.4.2.1.2
The VPI value for this connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

vpXOutIndex 1.3.6.1.4.1.2.6.33.1.4.2.1.3
The interface number for this ATM port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IfIndex  

vpXOutVpi 1.3.6.1.4.1.2.6.33.1.4.2.1.4
The VPI value for this connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

vpXType 1.3.6.1.4.1.2.6.33.1.4.2.1.5
Whether this cross-connection is part of a unicast or a multicast connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unicast(1), multicast(2)  

vpXDirection 1.3.6.1.4.1.2.6.33.1.4.2.1.6
Whether this entry identifies this cross-connection in the upstream or downstream flow, as seen from the root. Downstream means that the connection was set up from the in parameters (interface, VPI) to the out parameters (interface, VPI). Upstream means that the connection was set up from the out parameters (interface, VPI) to the in parameters (interface, VPI). As a result, any cross-connection is modeled in this table as two entries, depending on whether it is seen in the up or down stream.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER upstream(1), downstream(2)  

neighbor 1.3.6.1.4.1.2.6.33.1.5
OBJECT IDENTIFIER    

nbrTable 1.3.6.1.4.1.2.6.33.1.5.1
This table contains basic characteristics on adjacent ATM devices attached to this switch.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NbrEntry

nbrEntry 1.3.6.1.4.1.2.6.33.1.5.1.1
Entries of neighborTable. Each entry corresponds to a port that belongs to an ATM module. This module must be inserted in a slot that is attached to the ATM switch.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NbrEntry  

localIndex 1.3.6.1.4.1.2.6.33.1.5.1.1.1
The interface number for the port represented by this entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IfIndex  

nbrIpAddress1 1.3.6.1.4.1.2.6.33.1.5.1.1.2
One of the IP addresses of the ATM SNMP agent of the node attached to the port/slot defined by this entry. When not available, 0.0.0.0 is returned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

nbrIpAddress2 1.3.6.1.4.1.2.6.33.1.5.1.1.3
One of the IP addresses of the ATM SNMP agent of the node attached to the port/slot defined by this entry. When not available, 0.0.0.0 is returned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

nbrAtmAddress 1.3.6.1.4.1.2.6.33.1.5.1.1.4
The ATM identification of the node attached to the port/slot defined by this entry. When not available, a null string is returned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  AtmAddress  

nbrIndex 1.3.6.1.4.1.2.6.33.1.5.1.1.5
The interface number of the adjacent node to which the connection defined by this entry is attending. When not available, 0 is returned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IfIndex  

nbrDescriptor 1.3.6.1.4.1.2.6.33.1.5.1.1.6
The value of the MIB-II sysDescr as reported by the device attached to this port. When not available, a null string is returned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

nbrOid 1.3.6.1.4.1.2.6.33.1.5.1.1.7
The value of the MIB-II sysOID as reported by the device attached to this port. When not available, a null string is returned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

nbrName 1.3.6.1.4.1.2.6.33.1.5.1.1.8
The value of the MIB-II sysName as reported by the device attached to this port. When not available, a null string is returned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

nbrLocation 1.3.6.1.4.1.2.6.33.1.5.1.1.9
The value of the MIB-II sysLocation as reported by the device attached to this port. When not available, a null string is returned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

trunkId 1.3.6.1.4.1.2.6.33.1.5.1.1.10
The internal identifier for this trunk. Set to 0 if not a trunk.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

tftp 1.3.6.1.4.1.2.6.33.1.6
OBJECT IDENTIFIER    

transferControl 1.3.6.1.4.1.2.6.33.1.6.1
A file transfer is initiated through a start command.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ready(1), download(2), upload(3)  

transferDate 1.3.6.1.4.1.2.6.33.1.6.2
The date and time of the last transfer.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DateAndTime  

serverIpAddress 1.3.6.1.4.1.2.6.33.1.6.3
The IP address of the server used for file transfer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

fileName 1.3.6.1.4.1.2.6.33.1.6.4
The name of the file to transfer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..128)  

fileType 1.3.6.1.4.1.2.6.33.1.6.5
The type of file to transfer. Boot and operational codes can only be dowlnoaded. Logs, traces and dumps can only be uploaded.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), bootCode(2), operationalCode(3), errorLog(4), systemTrace(5), trsTrace(6), trsDump(8)  

fileTarget 1.3.6.1.4.1.2.6.33.1.6.6
The module target to which the transfer applies. When set to 0, the transfer applies to the agent itself.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

transferResult 1.3.6.1.4.1.2.6.33.1.6.7
The result of the latest file transfer. When one of the TFTP variables is modified, this variable is reset to not-initialized.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER not-initialized(1), transfer-successful(2), upload-in-progress(3), download-in-progress(4), generic-error(5), no-response-from-host(6), connection-lost(7), file-not-found(8), file-empty(9), file-too-big(10), access-rights-violation(11), invalid-file-header(12), checksum-error(13), transfer-error(14), hardware-error(15)  

service 1.3.6.1.4.1.2.6.33.1.7
OBJECT IDENTIFIER    

traces 1.3.6.1.4.1.2.6.33.1.7.1
OBJECT IDENTIFIER    

sysTrace 1.3.6.1.4.1.2.6.33.1.7.1.1
When on, the hub general trace facility is started. Messages are stored in the hub in a file that can be retrieved through TFTP. When off, the general trace facility is stopped and messages are no longer logged.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2)  

trsTrace 1.3.6.1.4.1.2.6.33.1.7.1.2
When on, the Topology and Routing Selection trace is started. Messages are stored in the hub in a file that can be retrieved through TFTP. When off, the control point trace facility is stopped and messages are no longer logged.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2)  

dumps 1.3.6.1.4.1.2.6.33.1.7.2
OBJECT IDENTIFIER    

trsDump 1.3.6.1.4.1.2.6.33.1.7.2.2
When start is selected, a dump of the Topology and Route Services component is taken. The dump is stored in the hub in a file that can be retrieved through TFTP.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ready(1), start(2)  

swap 1.3.6.1.4.1.2.6.33.1.7.3
OBJECT IDENTIFIER    

swapControl 1.3.6.1.4.1.2.6.33.1.7.3.1
When swap is selected, the backup microcode image is checked and, if valid, activated. The previously active microcode image becomes the backup image. The atm subsystem is reset.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ready(1), swap(2)  

swapResult 1.3.6.1.4.1.2.6.33.1.7.3.2
The result of the latest microcode swap. When an operational code image is downloaded or when the system is reset, swapControl becomes not-initialized.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER not-initialized(1), swap-successful(2), swap-in-progress(3), checksum-error(4)  

atmSvc 1.3.6.1.4.1.2.6.33.1.9
OBJECT IDENTIFIER    

atmQ2931 1.3.6.1.4.1.2.6.33.1.9.1
OBJECT IDENTIFIER    

atmQ2931ConfTable 1.3.6.1.4.1.2.6.33.1.9.1.1
This table contains basic information on the Q2931 protocol for each signalling link defined per port. Usually, there is only one signalling channel per interface and thus one Q2931 protocol definition entry per interface.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmQ2931ConfEntry

atmQ2931ConfEntry 1.3.6.1.4.1.2.6.33.1.9.1.1.1
Entries of atmQ2931ConfTable. Each entry corresponds to a pair of ATM interface, signalling channel. A signalling channel is uniquely defined on each interface by the VPI and VCI values allocated to it.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AtmQ2931ConfEntry  

atmQ2931ConfIndex 1.3.6.1.4.1.2.6.33.1.9.1.1.1.1
The ifIndex value of the ATM interface which, with the signalling channel defined by its Vpi/Vci values, uniquely identifies this entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IfIndex  

atmQ2931SiVpi 1.3.6.1.4.1.2.6.33.1.9.1.1.1.2
The Vpi value which, with the Vci value specified in atmQ2931SiVci, defines the signalling channel for this entry. Usually, there is one signalling channel per interface defined by Vpi=0,Vci=5.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmQ2931SiVci 1.3.6.1.4.1.2.6.33.1.9.1.1.1.3
The Vci value which, with the Vpi value specified in atmQ2931SiVpi, defines the signalling channel for this entry. Usually, there is one signalling channel per interface defined by Vpi=0,Vci=5.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmQ2931T303 1.3.6.1.4.1.2.6.33.1.9.1.1.1.4
T303 timer as defined in the ATM UNI Specification.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmQ2931T308 1.3.6.1.4.1.2.6.33.1.9.1.1.1.5
T308 timer as defined in the ATM UNI Specification.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmQ2931T309 1.3.6.1.4.1.2.6.33.1.9.1.1.1.6
T309 timer as defined in the ATM UNI Specification.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmQ2931T310 1.3.6.1.4.1.2.6.33.1.9.1.1.1.7
T310 timer as defined in the ATM UNI Specification.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmQ2931T316 1.3.6.1.4.1.2.6.33.1.9.1.1.1.8
T316 timer as defined in the ATM UNI Specification.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmQ2931T317 1.3.6.1.4.1.2.6.33.1.9.1.1.1.9
T317 timer as defined in the ATM UNI Specification.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmQ2931T322 1.3.6.1.4.1.2.6.33.1.9.1.1.1.10
T322 timer as defined in the ATM UNI Specification.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmQ2931T398 1.3.6.1.4.1.2.6.33.1.9.1.1.1.11
T398 timer as defined in the ATM UNI Specification.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmQ2931T399 1.3.6.1.4.1.2.6.33.1.9.1.1.1.12
T399 timer as defined in the ATM UNI Specification.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmQ2931SetupRetry 1.3.6.1.4.1.2.6.33.1.9.1.1.1.13
Number of set-up retries as defined in the ATM UNI Specification.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmQ2931ReleaseRetry 1.3.6.1.4.1.2.6.33.1.9.1.1.1.14
Number of release retries as defined in the ATM UNI Specification.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmQ2931RestartRetry 1.3.6.1.4.1.2.6.33.1.9.1.1.1.15
Number of restart retries as defined in the ATM UNI Specification.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmQ2931StatusRetry 1.3.6.1.4.1.2.6.33.1.9.1.1.1.16
Number of status retries as defined in the ATM UNI Specification.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmQ2931StatsTable 1.3.6.1.4.1.2.6.33.1.9.1.2
This table contains statistics for the Q2931 protocol.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmQ2931StatsEntry

atmQ2931StatsEntry 1.3.6.1.4.1.2.6.33.1.9.1.2.1
Entries of atmQ2931ConfTable. Each entry corresponds to a pair of ATM interface, signalling channel. A signalling channel is uniquely defined on each interface by the VPI and VCI values allocated to it.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AtmQ2931StatsEntry  

atmQ2931StatsIndex 1.3.6.1.4.1.2.6.33.1.9.1.2.1.1
The ifIndex value of the ATM interface which, with the signalling channel defined by its Vpi/Vci values, uniquely identifies this entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IfIndex  

atmQ2931StatsVpi 1.3.6.1.4.1.2.6.33.1.9.1.2.1.2
The Vpi value which, with the Vci value specified in atmQ2931StatsVci, defines the signalling channel for this entry. Usually, there is one signalling channel per interface defined by Vpi=0,Vci=5.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmQ2931StatsVci 1.3.6.1.4.1.2.6.33.1.9.1.2.1.3
The Vci value which, with the Vpi value specified in atmQ2931StatsVpi, defines the signalling channel for this entry. Usually, there is one signalling channel per interface defined by Vpi=0,Vci=5.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmQ2931OutCallAttempts 1.3.6.1.4.1.2.6.33.1.9.1.2.1.4
This is the number of outgoing call attempts on this interface, including accepted as well as rejected calls.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

atmQ2931OutCallInProgess 1.3.6.1.4.1.2.6.33.1.9.1.2.1.5
This is the current number of outgoing calls in progress on this interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

atmQ2931OutCallFailures 1.3.6.1.4.1.2.6.33.1.9.1.2.1.6
This is the number of outgoing calls that were cleared for a reason other than a DTE or operator initiated action.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

atmQ2931InCallAttempts 1.3.6.1.4.1.2.6.33.1.9.1.2.1.7
This is the number of incoming call attempts on this interface, including accepted as well as rejected calls.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

atmQ2931InCallInProgress 1.3.6.1.4.1.2.6.33.1.9.1.2.1.8
This is the current number of incoming calls in progress on this interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

atmQ2931InCallFailures 1.3.6.1.4.1.2.6.33.1.9.1.2.1.9
This is the number of calls that were rejected by the receiver.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

atmSvcTable 1.3.6.1.4.1.2.6.33.1.9.1.3
This table contains basic information for each active Switched Virtual Connection (SVC).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmSvcEntry

atmSvcEntry 1.3.6.1.4.1.2.6.33.1.9.1.3.1
Entries of atmSvcTable. Each entry uniquely defines two end-points of an SVC. In the case of a multicast SVC, each entry is defined by the association of the root and one party.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AtmSvcEntry  

atmSvcInterfaceIndex 1.3.6.1.4.1.2.6.33.1.9.1.3.1.1
The ifIndex value of the ATM interface used by this SVC.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IfIndex  

atmSvcSiVpi 1.3.6.1.4.1.2.6.33.1.9.1.3.1.2
The Vpi value which, with the Vci value specified in atmQ2931SiVci, defines the signalling channel for this entry. Usually, there is one signalling channel per interface defined by Vpi=0,Vci=5.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmSvcSiVci 1.3.6.1.4.1.2.6.33.1.9.1.3.1.3
The Vci value which, with the Vpi value specified in atmQ2931SiVpi, defines the signalling channel for this entry. Usually, there is one signalling channel per interface defined by Vpi=0,Vci=5.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmSvcCallReference 1.3.6.1.4.1.2.6.33.1.9.1.3.1.4
The Q2931 call reference value used for this SVC.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..8388607  

atmSvcEndPointReference 1.3.6.1.4.1.2.6.33.1.9.1.3.1.5
One of the Q2931 end point reference values used by this SVC. In a unicast SVC, there is only one entry for this SVC in the table. In a multicast SVC, there is one entry per party.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..16383  

atmSvcCallingNumber 1.3.6.1.4.1.2.6.33.1.9.1.3.1.6
The calling number carried in the calling party number information element of the call set-up message.
Status: mandatory Access: read-only
OBJECT-TYPE    
  AtmAddress  

atmSvcCalledNumber 1.3.6.1.4.1.2.6.33.1.9.1.3.1.7
The called number carried in the called party number information element of the call set-up message.
Status: mandatory Access: read-only
OBJECT-TYPE    
  AtmAddress  

atmSvcClear 1.3.6.1.4.1.2.6.33.1.9.1.3.1.8
This variable allows a network manager to clear this SVC. When this SVC is cleared (either by the manager using this variable or by one of the parties), the entry is deleted from this table and another entry is created in the atmSvcClearTable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER active(1), clear(2)  

atmSvcCreationTime 1.3.6.1.4.1.2.6.33.1.9.1.3.1.9
The date and time this call was placed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DateAndTime  

atmSvcVpi 1.3.6.1.4.1.2.6.33.1.9.1.3.1.10
The VPI value used by this SVC for this interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

atmSvcVci 1.3.6.1.4.1.2.6.33.1.9.1.3.1.11
The VCI value used by this SVC for this interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

atmSvcLogSize 1.3.6.1.4.1.2.6.33.1.9.1.4
The maximum number of entries supported by this local SNMP agent. When this value is exceeded, the entries are wrapped.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmSvcLogLevel 1.3.6.1.4.1.2.6.33.1.9.1.5
The maximum number of entries that can be written in the atmSvcLogTable before a trap is generated. When this number is reached, an svcLogOverflow trap is generated. When set to 0, no trap is generated.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

atmSvcLogTable 1.3.6.1.4.1.2.6.33.1.9.1.6
This table contains a list of the latest Switched Virtual Connection (SVC) that were completed on this ATM node. An SVC is completed when it has been torn down at the originator's request (normal completion) or by the network operator (forced tear down), or when it has been rejected or cleared by the network (exceptional condition).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmSvcLogEntry

atmSvcLogEntry 1.3.6.1.4.1.2.6.33.1.9.1.6.1
Entries of atmSvcLogTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AtmSvcLogEntry  

atmSvcLogIndex 1.3.6.1.4.1.2.6.33.1.9.1.6.1.1
An identification value for this entry, assigned by the local SNMP agent. This value is assigned for each new SVC call or add-party request. This index is allocated in a decreasing order, so that a get-next request on the table allows to retrieve the latest calls first.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmSvcLogInterfaceIndex 1.3.6.1.4.1.2.6.33.1.9.1.6.1.2
The ifIndex value of the ATM interface used by this SVC.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IfIndex  

atmSvcLogCallingNumber 1.3.6.1.4.1.2.6.33.1.9.1.6.1.3
The calling number carried in the calling party number information element of the call set-up message.
Status: mandatory Access: read-only
OBJECT-TYPE    
  AtmAddress  

atmSvcLogCalledNumber 1.3.6.1.4.1.2.6.33.1.9.1.6.1.4
The called number carried in the called party number information element of the call set-up message.
Status: mandatory Access: read-only
OBJECT-TYPE    
  AtmAddress  

atmSvcLogCreationTime 1.3.6.1.4.1.2.6.33.1.9.1.6.1.5
The date and time this call was placed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DateAndTime  

atmSvcLogTime 1.3.6.1.4.1.2.6.33.1.9.1.6.1.6
The date and time this call was cleared.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DateAndTime  

atmSvcLogClearCause 1.3.6.1.4.1.2.6.33.1.9.1.6.1.7
The cause of the clearing of this SVC.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmSvcLogForwardQOS 1.3.6.1.4.1.2.6.33.1.9.1.6.1.8
The forward Quality Of Service requested for this call.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unspecified(0), class-A(1), class-B(2), class-C(3), class-D(4)  

atmSvcLogBackwardQOS 1.3.6.1.4.1.2.6.33.1.9.1.6.1.9
The backward Quality Of Service requested for this call.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unspecified(0), class-A(1), class-B(2), class-C(3), class-D(4)  

atmSvcLogForwardBW 1.3.6.1.4.1.2.6.33.1.9.1.6.1.10
The forward bandwidth requested for this call.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmSvcLogBackwardBW 1.3.6.1.4.1.2.6.33.1.9.1.6.1.11
The backward bandwidth requested for this call.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmSaal 1.3.6.1.4.1.2.6.33.1.9.2
OBJECT IDENTIFIER    

atmSaalConfTable 1.3.6.1.4.1.2.6.33.1.9.2.1
This table contains basic information on the SAAL protocol for each signalling link defined per port. Usually, there is only one signalling channel per interface and thus one SAAL protocol definition entry per interface.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmSaalConfEntry

atmSaalConfEntry 1.3.6.1.4.1.2.6.33.1.9.2.1.1
Entries of atmSaalConfTable. Each entry corresponds to a pair of ATM interface, signalling channel. A signalling channel is uniquely defined on each interface by the VPI and VCI values allocated to it.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AtmSaalConfEntry  

atmSaalConfIndex 1.3.6.1.4.1.2.6.33.1.9.2.1.1.1
The ifIndex value of the ATM interface which, with the signalling channel defined by its Vpi/Vci values, uniquely identifies this entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IfIndex  

atmSaalConfSiVpi 1.3.6.1.4.1.2.6.33.1.9.2.1.1.2
The Vpi value which, with the Vci value specified in atmSaalConfSiVci, defines the signalling channel for this entry. Usually, there is one signalling channel per interface defined by Vpi=0,Vci=5.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmSaalConfSiVci 1.3.6.1.4.1.2.6.33.1.9.2.1.1.3
The Vci value which, with the Vpi value specified in atmSaalConfSiVpi, defines the signalling channel for this entry. Usually, there is one signalling channel per interface defined by Vpi=0,Vci=5.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmSaalState 1.3.6.1.4.1.2.6.33.1.9.2.1.1.4
The state of the SAAL for this interface as defined in the Q.2110 Specification, Chapter 7.3.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmSaalTimerPoll 1.3.6.1.4.1.2.6.33.1.9.2.1.1.5
Timer_POLL as defined in the Q.2110 Specification. This timer is running in the active phase to assure that the peer receiver is polled often enough to return its status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmSaalTimerKeepAlive 1.3.6.1.4.1.2.6.33.1.9.2.1.1.6
Timer_KEEP-ALIVE as defined in the Q.2110 Specification. This timer is started when entering the transient phase.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmSaalTimerNoResponse 1.3.6.1.4.1.2.6.33.1.9.2.1.1.7
Timer_NO-RESPONSE as defined in the Q.2110 Specification. This timer indicates the maximum time interval during which at least one STAT PDU needs to be received.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmSaalTimerCC 1.3.6.1.4.1.2.6.33.1.9.2.1.1.8
Timer_CC as defined in the Q.2110 Specification. Transmission of PDUs is protected by this timer during establishment and release of a connection and during resynchronization or recovery.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmSaalTimerIdle 1.3.6.1.4.1.2.6.33.1.9.2.1.1.9
Timer_IDLE as defined in the Q.2110 Specification. This timer is started upon receipt of a STAT PDU when entering the idle phase (no POLL PDUs sent).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmSaalMaxCC 1.3.6.1.4.1.2.6.33.1.9.2.1.1.10
MaxCC as defined in the Q.2110 Specification. This is the maximum value for the state variable VT(CC), corresponding to the maximum number of transmissions of a BGN, END, ER or RS PDU.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmSaalMaxPD 1.3.6.1.4.1.2.6.33.1.9.2.1.1.11
MaxPD as defined in the Q.2110 Specification. This is the maximum iacceptable value for the state variable VT(PD) before sending a POLL PDU and resetting VT(PD) to zero. This parameter is an upper limit for counter VT(PD) that sends a POLL PDU after every (MaxPD) SD PDUs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmSaalMaxStat 1.3.6.1.4.1.2.6.33.1.9.2.1.1.12
MaxSTAT as defined in the Q.2110 Specification. This is the maximum number of list elements placed in a STAT PDU.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmSaalStatsTable 1.3.6.1.4.1.2.6.33.1.9.2.2
This table contains statistics for the SAAL protocol, for outgoing calls only.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmSaalStatsEntry

atmSaalStatsEntry 1.3.6.1.4.1.2.6.33.1.9.2.2.1
Entries of atmSaalConfTable. Each entry corresponds to a pair of ATM interface, signalling channel. A signalling channel is uniquely defined on each interface by the VPI and VCI values allocated to it.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AtmSaalStatsEntry  

atmSaalStatsIndex 1.3.6.1.4.1.2.6.33.1.9.2.2.1.1
The ifIndex value of the ATM interface which, with the signalling channel defined by its Vpi/Vci values, uniquely identifies this entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IfIndex  

atmSaalStatsSiVpi 1.3.6.1.4.1.2.6.33.1.9.2.2.1.2
The Vpi value which, with the Vci value specified in atmSaalStatsSiVci, defines the signalling channel for this entry. Usually, there is one signalling channel per interface defined by Vpi=0,Vci=5.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmSaalStatsSiVci 1.3.6.1.4.1.2.6.33.1.9.2.2.1.3
The Vci value which, with the Vpi value specified in atmSaalStatsSiVpi, defines the signalling channel for this entry. Usually, there is one signalling channel per interface defined by Vpi=0,Vci=5.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmSaalUnexpectPdus 1.3.6.1.4.1.2.6.33.1.9.2.2.1.4
Error conditions A to M, as defined in the Q.2110 Specification. This is the number of received unsolicited or or inappropriate PDUs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

atmSaalUnsuccessPdus 1.3.6.1.4.1.2.6.33.1.9.2.2.1.5
Error condition O as defined in the Q.2110 Specification. This is the number of failing retries.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

atmSaalFailedEstablishment 1.3.6.1.4.1.2.6.33.1.9.2.2.1.6
Error condition P as defined in the Q.2110 Specification. This is the number of failing polls.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

atmSaalSequenceGap 1.3.6.1.4.1.2.6.33.1.9.2.2.1.7
The number of times sequence gaps were detected by the peer entity.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

atmSaalGapNumbers 1.3.6.1.4.1.2.6.33.1.9.2.2.1.8
The number of times frames were re-transmitted due to sequence gaps detected by the peer entity.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

atmSaalOtherListErrors 1.3.6.1.4.1.2.6.33.1.9.2.2.1.9
Error conditions Q to V as defined in the Q.2110 Specification.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

atmSaalLackOfCredit 1.3.6.1.4.1.2.6.33.1.9.2.2.1.10
Error condition W as defined in the Q.2110 Specification. This is the number of times that transmission was not permitted by the peer entity due to a lack of credit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

atmSaalCreditObtained 1.3.6.1.4.1.2.6.33.1.9.2.2.1.11
Error condition X as defined in the Q.2110 Specification. This is the number of times that credit was obtained from the peer entity to allow transmission.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

atmPvc 1.3.6.1.4.1.2.6.33.1.10
OBJECT IDENTIFIER    

atmPvcHandler 1.3.6.1.4.1.2.6.33.1.10.1
The status of the PVC handler in the switch. When no more memory is available, the creation of new PVCs is rejected with a generic Error sense code.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ready(1), out-of-memory(2)  

atmPvcTable 1.3.6.1.4.1.2.6.33.1.10.2
This table lists all PVCs defined per interface. There is only one entry in this table per PVC (point-to-point or point-to-multipoint PVC).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmPvcEntry

atmPvcEntry 1.3.6.1.4.1.2.6.33.1.10.2.1
Entries of atmPvcTable. Policing parameters are those requested when creating the PVC. The actual values used by the network to satisfy these requirements may slightly differ. These values are attached to virtual links and are available in virtual link tables, such as the RFC-1695 VPL/VCL tables.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AtmPvcEntry  

atmPvcIndex 1.3.6.1.4.1.2.6.33.1.10.2.1.1
The ifIndex value of the ATM interface used by this PVC.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IfIndex  

atmPvcIdentifier 1.3.6.1.4.1.2.6.33.1.10.2.1.2
A value used to uniquely identify this PVC on this interface. To create a new PVC on a given interface, an unused PVC identifier must be found.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmPvcRowStatus 1.3.6.1.4.1.2.6.33.1.10.2.1.3
States values: active: the PVC is operational notInService: the PVC is failing notReady: values are missing to be able to activate this PVC Actions: active: this requests to re-start a failing PVC (which status was notInService) destroy: this requests to delete a PVC createAndWait: this requests to create a PVC To create a new PVC, this variable must be set to createAndWait with an index where: - atmPvcIndex is the number of the interface from where the PVC is created - atmPvcIdentifier is an unused PVC identifier for this interface To activate a PVC, this variable must be set to active. Default values are provided for all attributes except for the atmPvcEpRemIndex. If this attribute is not set, the PVC will remain in the notReady state. To delete a point-to-point PVC, this variable must be set to destroy.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER active(1), notInService(2), notReady(3), createAndWait(5), destroy(6)  

atmPvcType 1.3.6.1.4.1.2.6.33.1.10.2.1.4
A unicast PVC is defined between two endpoints, using either a VP or a VC connection.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER point2pointVP(1), point2pointVC(2)  

atmPvcEndPoint 1.3.6.1.4.1.2.6.33.1.10.2.1.5
The end-point where the PVC is created is identified as the primary or root end-point. the other end-point is the identified as the secondary or leaf end-point.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER primaryRoot(1), secondaryLeaf(2)  

atmPvcVpi 1.3.6.1.4.1.2.6.33.1.10.2.1.6
The VPI value assigned to this PVC at the origin. A value of 65536 means that no value has been specified by the operator. If no value has been specified, the VPI value is then automatically allocated by the agent when activating the PVC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65536  

atmPvcVci 1.3.6.1.4.1.2.6.33.1.10.2.1.7
The VCI value assigned to this PVC at the origin. For VP-type PVC, this value is not applicable and is set to 0. A value of 65536 means that no value has been specified by the operator. If no value has been specified, the VCI value is then automatically allocated by the agent when activating the PVC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65536  

atmPvcBackwardQos 1.3.6.1.4.1.2.6.33.1.10.2.1.8
The QOS requested for this PVC to the originator.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unspecified(0), class-A(1)  

atmPvcForwardQos 1.3.6.1.4.1.2.6.33.1.10.2.1.9
The QOS requested for this PVC from the originator.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unspecified(0), class-A(1)  

atmPvcBackwardType 1.3.6.1.4.1.2.6.33.1.10.2.1.10
The first parameter used to define the policy requested for this PVC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OBJECT IDENTIFIER  

atmPvcForwardType 1.3.6.1.4.1.2.6.33.1.10.2.1.11
The type of policy requested for this PVC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OBJECT IDENTIFIER  

atmPvcBackwardParm1 1.3.6.1.4.1.2.6.33.1.10.2.1.12
The fourth parameter used to define the policy requested for this PVC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

atmPvcForwardParm1 1.3.6.1.4.1.2.6.33.1.10.2.1.13
The third parameter used to define the policy requested for this PVC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

atmPvcEpTable 1.3.6.1.4.1.2.6.33.1.10.3
This table lists the characteristics of the remote end-points of defined PVCs. There is one entry for each PVC defined in the atmPvcTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmPvcEpEntry

atmPvcEpEntry 1.3.6.1.4.1.2.6.33.1.10.3.1
Entries of atmPvcEpTable. One entry is automatically created by the agent when a PVC is created in the PVC Table. No additional entry can be created in this table if the PVC is defined as point-to-point in the PVC table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AtmPvcEpEntry  

atmPvcEpIndex 1.3.6.1.4.1.2.6.33.1.10.3.1.1
The ifIndex value of the ATM interface used by this PVC.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IfIndex  

atmPvcEpIdentifier 1.3.6.1.4.1.2.6.33.1.10.3.1.2
A value used to uniquely identify this PVC on this interface. This is the same identifier as the one used in the atmPvcTable to identify the PVC that this end-point belongs to.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmPvcEpParty 1.3.6.1.4.1.2.6.33.1.10.3.1.3
A value used to uniquely identify a remote end-point of a PVC, when associated with an interface index and a PVC identifier. For a point-to-point PVC, this value is always set to 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmPvcEpRowStatus 1.3.6.1.4.1.2.6.33.1.10.3.1.4
States values: active: the PVC is operational notInService: the PVC is failing notReady: values are missing to be able to activate this PVC Actions: active: this requests to re-start a failing unicast PVC (status was notInService) destroy: this requests to delete a unicast PVC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER active(1), notInService(2), notReady(3), destroy(6)  

atmPvcEpStatusCause 1.3.6.1.4.1.2.6.33.1.10.3.1.5
A detailed cause for the current PVC status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noCause(1), underModification(2), missingParameters(3), invalidParameters(4), uncompatibleParameters(5), internalFailure(6), pvcFailure(7), unavailableResource(8), remoteBusy(9), retrying(10)  

atmPvcEpRemAddress 1.3.6.1.4.1.2.6.33.1.10.3.1.6
The ATM address of the remote ATM switch where the PVC ends. If none is specified, the ATM address of the target switch (local) is used and the PVC is confined to the target switch (local switch).
Status: mandatory Access: read-write
OBJECT-TYPE    
  NetPrefix  

atmPvcEpRemIndex 1.3.6.1.4.1.2.6.33.1.10.3.1.7
The ifindex value used at the remote end to identify the interface where the PVC ends. This entry will remain in the notReady state until this attribute is set (and the atmPvcRowStatus is set to active).
Status: mandatory Access: read-write
OBJECT-TYPE    
  IfIndex  

atmPvcEpRemVpi 1.3.6.1.4.1.2.6.33.1.10.3.1.8
The VPI value assigned to this PVC at the destination (remote end). If left at 65536 (default value), one value is automatically allocated by the agent.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65536  

atmPvcEpRemVci 1.3.6.1.4.1.2.6.33.1.10.3.1.9
The VCI value assigned to this PVC at the destination. For VP-type PVC, this value is not applicable and is set to 0. If left at 65536 (default value), one value is automatically allocated by the agent (for VC only).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65536  

atmPvcEpLastActive 1.3.6.1.4.1.2.6.33.1.10.3.1.10
The date and time of the latest PVC activation.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DateAndTime  

atmPvcEpQ2931Cause 1.3.6.1.4.1.2.6.33.1.10.3.1.11
The cause of the failure as defined by Q2931.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

atmPvcEpFailures 1.3.6.1.4.1.2.6.33.1.10.3.1.12
The number of times this PVC failed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

hello 1
A hello trap is sent: - when the system re-initializes: it is sent every minutes until an SNMP request is received or until 255 minutes have passed. - when one of the following parameters is changed: -- agent IP address(es) -- agent subnet mask(s) -- ATM address of the IP ARP server -- IP address of the default gateway The value of ifPhysAddress is the ATM address of the hub. The hello trap may be disabled.
TRAP-TYPE    

lock 2
A lock trap is sent when a set request is rejected because it is suspected that this may cause to break the link between the agent and the manager. This may occur when: - isolating a slot - disabling a port if the request is received through this specific port/module/slot.
TRAP-TYPE    

change 3
A change trap is sent when one of the following MIB variables or group of variables is changed: - Date and Time reset - System Parameters (name, contact, location) changed - Interface changed: -- Administrative State (enabled/disabled) - Module changed: -- Administrative State (isolate/attach) When one of this variable is changed, the lastChange MIB object is also updated with the current date and time. When the Date and Time or the System Parameters changed, the interface number of the hub virtual interface is returned. This trap may be disabled.
TRAP-TYPE    

pvcFailure 4
A PVC failure trap is sent when a PVC becomes inoperational.
TRAP-TYPE    

callLoggingOverflow 6
A callLoggingOverflow trap is sent when the call logging table is about to wrap.
TRAP-TYPE    

moduleInstalled 7
An ATM module has been detected in the hub.
TRAP-TYPE    

moduleRemoved 8
An ATM module is no longer detected in the hub.
TRAP-TYPE