AV-AURA-SESSION-MANAGER-THIRDPARTY-MIB

File: AV-AURA-SESSION-MANAGER-THIRDPARTY-MIB.mib (9703 bytes)

Imported modules

SNMPv2-SMI INET-ADDRESS-MIB SNMPv2-CONF
SNMP-FRAMEWORK-MIB SNMPv2-TC

Imported symbols

MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
enterprises InetAddressIPv6 MODULE-COMPLIANCE
OBJECT-GROUP SnmpAdminString DateAndTime

Defined Values

avaya 1.3.6.1.4.1.6889
OBJECT IDENTIFIER    

products 1.3.6.1.4.1.6889.1
OBJECT IDENTIFIER    

mibs 1.3.6.1.4.1.6889.2
OBJECT IDENTIFIER    

avAuraSessMgrProd 1.3.6.1.4.1.6889.1.36
OBJECT IDENTIFIER    

avAuraSessMgrMibs 1.3.6.1.4.1.6889.2.36
This MIB module is for exposing Avaya Aura Session Manager inventory information via SNMP GET.
MODULE-IDENTITY    

avAuraSessMgrMibNotifications 1.3.6.1.4.1.6889.2.36.0
OBJECT IDENTIFIER    

avAuraSessMgrMibObjects 1.3.6.1.4.1.6889.2.36.1
OBJECT IDENTIFIER    

avAuraSessMgrMibConformance 1.3.6.1.4.1.6889.2.36.2
OBJECT IDENTIFIER    

avSessMgrTPBR4 1.3.6.1.4.1.6889.2.36.0.521
Postgres connection failure(Minor)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR5 1.3.6.1.4.1.6889.2.36.0.523
Postgres Integrity/Proctocol Violation(Minor)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR6 1.3.6.1.4.1.6889.2.36.0.525
Postgres invalid transaction failure(Minor)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR7 1.3.6.1.4.1.6889.2.36.0.527
Postgres insufficient resource failure(Minor)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR8 1.3.6.1.4.1.6889.2.36.0.529
Postgres resource issues failure(Minor)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR9 1.3.6.1.4.1.6889.2.36.0.5211
Postgres IO/Internal errors(Minor)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR10 1.3.6.1.4.1.6889.2.36.0.5213
Postgres connection/indexing issues(Minor)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR30 1.3.6.1.4.1.6889.2.36.0.531
Event 2057 Virtual disk degraded(Major)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR31 1.3.6.1.4.1.6889.2.36.0.533
Event 2048 Device failed(Major)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR32 1.3.6.1.4.1.6889.2.36.0.535
Event 2056/2076 Virtual disk failed(Major)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR33 1.3.6.1.4.1.6889.2.36.0.537
Event 2080/2083 Physical disk failed(Major)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR34 1.3.6.1.4.1.6889.2.36.0.539
Event 2107 Smart configuration change(Major)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR35 1.3.6.1.4.1.6889.2.36.0.5311
Event 2163 Rebuild completed with errors(Major)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR36 1.3.6.1.4.1.6889.2.36.0.5313
Event 2270/2272/2273 Disk media errors(Major)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR37 1.3.6.1.4.1.6889.2.36.0.5315
EventID 2282 Hot spare SMART polling failed(Major)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR38 1.3.6.1.4.1.6889.2.36.0.5317
EventID 2307 Bad block table is full. Unable to log block(Major)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR39 1.3.6.1.4.1.6889.2.36.0.5319
Event2347/2348/2349 Physical disk rebuild failures(Major)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR40 1.3.6.1.4.1.6889.2.36.0.5321
EventID 2350 There was an unrecoverable disk media error during the rebuild(Major)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR45 1.3.6.1.4.1.6889.2.36.0.5323
EventID 1354 Power supply detected a failure Sensor location PS [1 or 2](Major)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR50 1.3.6.1.4.1.6889.2.36.0.5325
EventIDs 2102/2103 Temperature reading errors(Major)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR60 1.3.6.1.4.1.6889.2.36.0.5327
EventID 2169 The controller battery needs to be replaced(Major)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR70 1.3.6.1.4.1.6889.2.36.0.5329
EventID 2268 Storage Management has lost communication with the controller(Major)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR80 1.3.6.1.4.1.6889.2.36.0.5331
EventID 2289/2299 Multi-bit ECC error / Bad Phy(Major)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR90 1.3.6.1.4.1.6889.2.36.0.5333
Event 2320/2321 DIMM Single-bit ECC error.(Major)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR100 1.3.6.1.4.1.6889.2.36.0.5335
EventID 2340 The BGI completed with uncorrectable errors(Major)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR200 1.3.6.1.4.1.6889.2.36.0.541
Power Supply sensor Power Unit - Redundancy Lost(Major)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR201 1.3.6.1.4.1.6889.2.36.0.543
Power Supply sensor Power Supply [1 or 2] - (Power Supply AC lost | Failure detected) Asserted(Major)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR210 1.3.6.1.4.1.6889.2.36.0.545
Drive Slot sensor Drive [0 or 1] - Drive Present Deasserted(Major)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR211 1.3.6.1.4.1.6889.2.36.0.547
Drive Slot sensor Drive [0 or 1] - In (Critical | Failed) Array Asserted(Major)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR212 1.3.6.1.4.1.6889.2.36.0.549
Drive Slot sensor Drive [0 or 1] - Rebuild Aborted Asserted(Major)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR213 1.3.6.1.4.1.6889.2.36.0.5411
Drive Slot sensor Drive [0 or 1] - Predictive Failure Asserted(Major)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR214 1.3.6.1.4.1.6889.2.36.0.5413
Drive Slot sensor Drive [0 or 1] - Drive Fault Asserted(Major)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR220 1.3.6.1.4.1.6889.2.36.0.5415
Ambient Temp Upper Critical going high(Major)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR230 1.3.6.1.4.1.6889.2.36.0.5417
Planar (3.3,5,12)V Upper Critical going high(Major)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR231 1.3.6.1.4.1.6889.2.36.0.5419
Planar (3.3,5,12)V Lower Critical going low(Major)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR232 1.3.6.1.4.1.6889.2.36.0.5421
Planar VBAT Lower Critical going low(Major)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR240 1.3.6.1.4.1.6889.2.36.0.5423
Fan Tach Lower Critical going low(Major)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR300 1.3.6.1.4.1.6889.2.36.0.551
Power Supply/Fan/Overheating alarms(Major)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR301 1.3.6.1.4.1.6889.2.36.0.553
HP hard drive alarms(Major)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR302 1.3.6.1.4.1.6889.2.36.0.555
HP RAID alarms(Major)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR303 1.3.6.1.4.1.6889.2.36.0.557
HP Memory alarms(Major)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR304 1.3.6.1.4.1.6889.2.36.0.559
RAID Battery alarms(Major)
Status: current Access: read-only
NOTIFICATION-TYPE    

avSessMgrTPBR305 1.3.6.1.4.1.6889.2.36.0.561
RAID Controller alarms(Major)
Status: current Access: read-only
NOTIFICATION-TYPE