AVICI-BAY-MIB
File:
AVICI-BAY-MIB.mib (44319 bytes)
Imported modules
Imported symbols
Defined Types
AviciBayEntry |
|
SEQUENCE |
|
|
|
|
aviciBayIndex |
AviciBayType |
|
|
aviciBayCriticalLed |
AviciLedValue |
|
|
aviciBayMajorLed |
AviciLedValue |
|
|
aviciBayMinorLed |
AviciLedValue |
|
|
aviciBayAlarmCutOff |
INTEGER |
|
|
aviciBayModTempCriticalThreshold |
Integer32 |
|
|
aviciBayModTempMajorThreshold |
Integer32 |
|
|
aviciBayModTempMinorThreshold |
Integer32 |
|
|
aviciBayTempCriticalThreshold |
Integer32 |
|
|
aviciBayTempMajorThreshold |
Integer32 |
|
|
aviciBayTempMinorThreshold |
Integer32 |
|
AviciBayControllerEntry |
|
SEQUENCE |
|
|
|
|
aviciBayControllerIndex |
INTEGER |
|
|
aviciBayControllerOperStatus |
INTEGER |
|
|
aviciBayControllerAdminStatus |
INTEGER |
|
|
aviciBayControllerPartNumber |
AviciPartNumberType |
|
|
aviciBayControllerSerialNumber |
AviciSerialNumberType |
|
|
aviciBayControllerRevision |
AviciRevisionType |
|
|
aviciBayControllerSoftwareVersion |
DisplayString |
|
|
aviciBayControllerFirmwareVersion |
DisplayString |
|
|
aviciBayControllerProductId |
AviciProductIdType |
|
|
aviciBayControllerProductSerialNumber |
AviciSerialNumberType |
|
|
aviciBayControllerProductRevision |
AviciRevisionType |
|
|
aviciBayControllerDescr |
DisplayString |
|
AviciBayVoltageEntry |
|
SEQUENCE |
|
|
|
|
aviciBayVoltageIndex |
INTEGER |
|
|
aviciBayVoltageType |
AviciVoltageType |
|
|
aviciBayVoltage |
Integer32 |
|
|
aviciBayVoltageStatus |
INTEGER |
|
|
aviciBayVoltageDescr |
DisplayString |
|
AviciBayFanEntry |
|
SEQUENCE |
|
|
|
|
aviciBayFanIndex |
INTEGER |
|
|
aviciBayFanAdminStatus |
INTEGER |
|
|
aviciBayFanOperStatus |
INTEGER |
|
|
aviciBayFanSpeed |
Integer32 |
|
|
aviciBayFanCurrTemp |
Integer32 |
|
|
aviciBayFanMaxTemp |
Gauge32 |
|
|
aviciBayFanLedStatus |
AviciLedValue |
|
|
aviciBayFanCurrFailures |
Integer32 |
|
|
aviciBayFanDescr |
DisplayString |
|
AviciBaySlotEntry |
|
SEQUENCE |
|
|
|
|
aviciSlotIndex |
AviciSlotType |
|
|
aviciBaySlotStatus |
INTEGER |
|
|
aviciBaySlotRxOctets |
Counter32 |
|
|
aviciBaySlotRxMessages |
Counter32 |
|
|
aviciBaySlotRxDiscards |
Counter32 |
|
|
aviciBaySlotRxProtoErrs |
Counter32 |
|
|
aviciBaySlotRxIOErrs |
Counter32 |
|
|
aviciBaySlotRxTimeouts |
Counter32 |
|
|
aviciBaySlotTxOctets |
Counter32 |
|
|
aviciBaySlotTxMessages |
Counter32 |
|
|
aviciBaySlotTxDiscards |
Counter32 |
|
|
aviciBaySlotTxProtoErrs |
Counter32 |
|
|
aviciBaySlotTxIOErrs |
Counter32 |
|
|
aviciBaySlotTxTimeouts |
Counter32 |
|
AviciBayBreakerEntry |
|
SEQUENCE |
|
|
|
|
aviciBayBreakerIndex |
Integer32 |
|
|
aviciBayBreakerType |
AviciHighAvailabilityType |
|
|
aviciBayBreakerStatus |
INTEGER |
|
|
aviciBayBreakerDescr |
DisplayString |
|
AviciBayCoAlarmEntry |
|
SEQUENCE |
|
|
|
|
aviciBayCoAlarmIndex |
INTEGER |
1..65535 |
|
aviciBayCoAlarmType |
INTEGER |
|
|
aviciBayCoAlarmDescr |
DisplayString |
|
|
aviciBayCoAlarmTime |
TimeTicks |
|
|
aviciBayCoAlarmUnitNum |
Integer32 |
|
|
aviciBayCoAlarmUnitType |
AviciUnitType |
|
Defined Values
aviciBayMIB |
1.3.6.1.4.1.2474.1.4 |
The MIB module for an Avici Bay. |
MODULE-IDENTITY |
|
|
|
aviciBayTable |
1.3.6.1.4.1.2474.1.4.1.1 |
This table contains parameters and state variables for
each Avici bay. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
AviciBayEntry |
|
aviciBayEntry |
1.3.6.1.4.1.2474.1.4.1.1.1 |
An entry containing management information for
each bay. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
AviciBayEntry |
|
|
aviciBayIndex |
1.3.6.1.4.1.2474.1.4.1.1.1.1 |
The index number of the bay entry. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
AviciBayType |
|
|
aviciBayAlarmCutOff |
1.3.6.1.4.1.2474.1.4.1.1.1.5 |
Central office alarms are triggered by a hardware condition.
A write can only use the value off. This turns off the
Central Office audible alarms. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
on(1), off(2) |
|
aviciBayModTempMajorThreshold |
1.3.6.1.4.1.2474.1.4.1.1.1.7 |
The module temperature in degrees C above which a major
alarm will be triggered. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
aviciBayModTempMinorThreshold |
1.3.6.1.4.1.2474.1.4.1.1.1.8 |
The module temperature in degrees C above which a minor
alarm will be triggered. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
aviciBayTempCriticalThreshold |
1.3.6.1.4.1.2474.1.4.1.1.1.9 |
The incoming ambient air temperature in degrees C above which
a critical alarm will be triggered. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
aviciBayTempMajorThreshold |
1.3.6.1.4.1.2474.1.4.1.1.1.10 |
The incoming ambient air temperature in degrees C above which
a major alarm will be triggered. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
aviciBayTempMinorThreshold |
1.3.6.1.4.1.2474.1.4.1.1.1.11 |
The incoming ambient air temperature in degrees C above which
a minor alarm will be triggered. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
aviciBayControllerEntry |
1.3.6.1.4.1.2474.1.4.1.2.1 |
A list of status and parameter values for
each bay. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
AviciBayControllerEntry |
|
|
aviciBayControllerIndex |
1.3.6.1.4.1.2474.1.4.1.2.1.1 |
The index number of the bay controller entry. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..2 |
|
aviciBayControllerOperStatus |
1.3.6.1.4.1.2474.1.4.1.2.1.2 |
The current operational status of the
bay controller. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
down(1), passive(2), active(3), failed(4) |
|
aviciBayControllerAdminStatus |
1.3.6.1.4.1.2474.1.4.1.2.1.3 |
The current admin status of the bay controller. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
reboot(1), passive(2), active(3), diagnostic(4) |
|
aviciBayVoltageTable |
1.3.6.1.4.1.2474.1.4.1.3 |
This table contains parameters and state variables for
voltage lines and rails. Each bay contains eight voltage
rails used for backplane communication. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
AviciBayVoltageEntry |
|
aviciBayVoltageEntry |
1.3.6.1.4.1.2474.1.4.1.3.1 |
A list of status and parameter values for
voltage lines and rails. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
AviciBayVoltageEntry |
|
|
aviciBayVoltageIndex |
1.3.6.1.4.1.2474.1.4.1.3.1.1 |
The index number of the voltage entry. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..18 |
|
aviciBayVoltage |
1.3.6.1.4.1.2474.1.4.1.3.1.3 |
The current actual logical voltage of the
line. The logical voltage is the mapped value
reported by the AD7870 ADC for the line. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
aviciBayVoltageStatus |
1.3.6.1.4.1.2474.1.4.1.3.1.4 |
The current state of the voltage device. If no failure has
occurred, the value of this object is inSpec. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
inSpec(1), outSpec(2) |
|
aviciBayFanTable |
1.3.6.1.4.1.2474.1.4.1.4 |
This table contains parameters and state variables
for blowers. There are up to 4 fans in a shelf
installed at the bottom of each bay. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
AviciBayFanEntry |
|
aviciBayFanEntry |
1.3.6.1.4.1.2474.1.4.1.4.1 |
A list of status and parameter values for a
fan controller. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
AviciBayFanEntry |
|
|
aviciBayFanIndex |
1.3.6.1.4.1.2474.1.4.1.4.1.1 |
The index number of the fan entry. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..4 |
|
aviciBayFanAdminStatus |
1.3.6.1.4.1.2474.1.4.1.4.1.2 |
The current administrative status of the fan. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
offline(1), autonomous(2), controlled(3) |
|
aviciBayFanOperStatus |
1.3.6.1.4.1.2474.1.4.1.4.1.3 |
The current operational status of the fan. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
offline(1), autonomous(2), controlled(3), failed(4) |
|
aviciBayFanSpeed |
1.3.6.1.4.1.2474.1.4.1.4.1.4 |
The current speed of the fan in RPM. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..2700 |
|
aviciBayFanCurrTemp |
1.3.6.1.4.1.2474.1.4.1.4.1.5 |
The current room temp at the fan in degrees C. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
aviciBayFanMaxTemp |
1.3.6.1.4.1.2474.1.4.1.4.1.6 |
The maximum temperature at the fan since
the bay controller booted in degrees C. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
aviciBayFanLedStatus |
1.3.6.1.4.1.2474.1.4.1.4.1.7 |
The current status of the fan's LED.
off -- Fan normal
red -- Fan failure
green -- Fan in autonomous mode (self-controlled) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
AviciLedValue |
|
|
aviciBayFanCurrFailures |
1.3.6.1.4.1.2474.1.4.1.4.1.8 |
This variable specifies this fan object's current failures.
A value of 0 means there are no current failures for this fan object. The value
represents a vector of bits, each specifying a type of fan failure:
- Bit 0 Communication failure
- Bit 1 General failure (fan jammed, etc.)
- Bit 2 Filter blocked
- Bit 3 Bad or absent internal thermistor
- Bit 4 Bad or absent external thermistor
- Bit 5 Fan temperature above minor threshold but less than major
- Bit 6 Fan temperature above major threshold but less than critical threshold
- Bit 7 Fan temperature above critical threshold
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..511 |
|
aviciBayFanDescr |
1.3.6.1.4.1.2474.1.4.1.4.1.9 |
A description of this fan object. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..255) |
|
aviciBaySlotTable |
1.3.6.1.4.1.2474.1.4.1.5 |
This table contains parameters and state variables
for the slots. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
AviciBaySlotEntry |
|
aviciBaySlotEntry |
1.3.6.1.4.1.2474.1.4.1.5.1 |
A list of status and parameter values
for each module in a TSR bay. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
AviciBaySlotEntry |
|
|
aviciSlotIndex |
1.3.6.1.4.1.2474.1.4.1.5.1.1 |
The index number of the slot entry. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
AviciSlotType |
|
|
aviciBaySlotStatus |
1.3.6.1.4.1.2474.1.4.1.5.1.2 |
The current state of the slot. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
empty(1), occupied(2), identified(3) |
|
aviciBaySlotRxOctets |
1.3.6.1.4.1.2474.1.4.1.5.1.3 |
The total number of slot octets received. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
aviciBaySlotRxDiscards |
1.3.6.1.4.1.2474.1.4.1.5.1.5 |
The total number of slot received messages
discarded for any reason. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
aviciBaySlotRxProtoErrs |
1.3.6.1.4.1.2474.1.4.1.5.1.6 |
The number of slot received messages
discarded due to protocol error. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
aviciBaySlotRxIOErrs |
1.3.6.1.4.1.2474.1.4.1.5.1.7 |
The number of slot received messages
discarded due to I/O error. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
aviciBaySlotRxTimeouts |
1.3.6.1.4.1.2474.1.4.1.5.1.8 |
The number of slot received messages
discarded due to module timeout error. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
aviciBaySlotTxDiscards |
1.3.6.1.4.1.2474.1.4.1.5.1.11 |
The total number of slot send messages
aborted for any reason. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
aviciBaySlotTxProtoErrs |
1.3.6.1.4.1.2474.1.4.1.5.1.12 |
The number of slot send messages
aborted due to protocol error. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
aviciBaySlotTxIOErrs |
1.3.6.1.4.1.2474.1.4.1.5.1.13 |
The number of slot send messages
aborted due to I/O error. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
aviciBaySlotTxTimeouts |
1.3.6.1.4.1.2474.1.4.1.5.1.14 |
The number of slot send messages
aborted due to module timeout error. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
aviciBayBreakerTable |
1.3.6.1.4.1.2474.1.4.1.6 |
This table contains parameters and state variables for
the 48-volt breakers at the top of the TSR chassis. There
are 4 mains and 4 backups, one pair for each of the 4
shelves. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
AviciBayBreakerEntry |
|
aviciBayBreakerEntry |
1.3.6.1.4.1.2474.1.4.1.6.1 |
The state and type of each breaker. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
AviciBayBreakerEntry |
|
|
aviciBayBreakerStatus |
1.3.6.1.4.1.2474.1.4.1.6.1.3 |
The current state of the breaker. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(1), open(2), closed(3) |
|
aviciBayCoActiveAlarmCount |
1.3.6.1.4.1.2474.1.4.1.7.1 |
The number of current events causing central office alarms in
this Avici bay. If there are no such current events, this
object contains the value 0 |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
aviciBayCoAlarmLastChange |
1.3.6.1.4.1.2474.1.4.1.7.2 |
The value of sysUpTime at the time the aviciBayCoAlarmTable
changed. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TimeTicks |
|
|
aviciBayCoAlarmEntry |
1.3.6.1.4.1.2474.1.4.1.8.1 |
A description of each active central office alarm. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
AviciBayCoAlarmEntry |
|
|
aviciBayCoAlarmIndex |
1.3.6.1.4.1.2474.1.4.1.8.1.1 |
The index of this central office alarm on this bay. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..65535 |
|
aviciBayCoAlarmType |
1.3.6.1.4.1.2474.1.4.1.8.1.2 |
The severity level of this central office alarm. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
critical(1), major(2), minor(3) |
|
aviciBayCoAlarmDescr |
1.3.6.1.4.1.2474.1.4.1.8.1.3 |
A description of the event that caused this central office
alarm. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..255) |
|
aviciBayCoAlarmTime |
1.3.6.1.4.1.2474.1.4.1.8.1.4 |
The time this event occurred in hundreths of a second since the
last time the system was rebooted. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TimeTicks |
|
|
aviciBayCoAlarmUnitNum |
1.3.6.1.4.1.2474.1.4.1.8.1.5 |
The identification number of the failing component. If there is
more than one failing component of the same unit type in a bay,
then the identification number is the bay number. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
aviciBayCoAlarmUnitType |
1.3.6.1.4.1.2474.1.4.1.8.1.6 |
The type of the failing component. If there is more than one
failing component of the same unit type in a bay, for example,
a fan, then this value is multipleFailures. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
AviciUnitType |
|
|
aviciBayControllerColdStart |
1.3.6.1.4.1.2474.1.4.3.0.1 |
The aviciBayControllerColdStart notification signifies that
the bay controller has powered-up. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
aviciBayControllerWarmStart |
1.3.6.1.4.1.2474.1.4.3.0.2 |
The aviciBayControllerWarmStart notification signifies that the
bay controller has been restarted. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
aviciBayControllerDown |
1.3.6.1.4.1.2474.1.4.3.0.3 |
The aviciBayControllerDown notification signifies that a
server is no longer communicating with the bay controller after
having established communication. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
aviciBayVoltageNotification |
1.3.6.1.4.1.2474.1.4.2.0.1 |
A Voltage notification is sent when a change is detected in the 5
volt backplane communication rails. These backplane
communication rails are used by the bay controller to
communicate with the occupant of a given slot. There are 8
rails, each servicing the slots in one half of a shelf in the
bay (aviciBayVoltageIndex == rail):
Rail Slots
==============
1 1 - 5
2 6 - 10
3 11 - 15
4 16 - 20
5 21 - 25
6 26 - 30
7 31 - 35
8 36 - 40
If the voltage is out of specification, the communication path
will not function. When a given backplane communication channel
is not functioning, modules serviced by this rail cannot be
discovered (if a module is inserted) and will not be authorized
to boot (if an existing module reboots). The current voltage is
reported in the aviciBayVoltage object. A human readable
description of the event triggering this notification is
included in the aviciSysTrapDescr object. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
aviciBayFanNotification |
1.3.6.1.4.1.2474.1.4.2.0.2 |
A Fan notification is sent when the specified fan detects a
fault or clears a fault. The current ambient air temperature
entering the fan is reported in the aviciBayFanCurrTemp object.
All existing fan faults are reported in the
aviciBayFanCurrFailures object as a bitmap. If no failures
exist, this object contains a 0. A human readable description
of the event triggering this notification is included in the
aviciSysTrapDescr object.
Communication Failure: This failure indicates that the cooling
module has been removed or the cooling module firmware is no
longer communicating with the bay controller. If a
communication failure occurs, the fans will run in autonomous
mode until communication with the bay controller is
reestablished. Once communication is established, the failure
is cleared.
General Failure: This failure indicates that the cooling module
firmware is able to communicate with the bay controller and is
reporting a broken fan. This could mean that the fan is burned
out, jammed, or the firmware is unable to sense fan speed due to
tachometer failure. When the problem is corrected, the failure
is cleared.
Filter Blocked: This failure indicates that the fan detected
that the filter is blocked. When the obstruction is removed
from the filter or the clogged air filter is replaced, this
failure will clear.
Bad or absent internal thermistor: This failure indicates that
the fan internal thermistor is missing or is not functioning.
If the thermister is not functioning, the fan cannot sense the
incoming ambient air temperature. The ambient temperature is
used to control fan speed in autonomous mode and when there are
no modules reporting their current temperature.
Bad or absent external thermistor: This failure indicates that
the fan external thermistor is expected to be installed and is
not functioning.
Minor temperature threshold: This failure indicates that the
incoming ambient air temperature is above the minor threshold
temperature, but below the major threshold temperature. Either
the cooling system in the building has failed, or it has
insufficient cooling capacity for the equipment in the room.
A rapid rise in temperature usually indicates cooling system
failure whereas a slow rise usually indicates insufficient
cooling capacity. When the temperature drops below the minor
threshold, this failure will clear.
Major temperature threshold: This failure indicates that the
incoming ambient air temperature is above the major threshold
temperature, but below the critical threshold temperature.
Either the cooling system in the building has failed, or it has
insufficient cooling capacity for the equipment in the room.
A rapid rise in temperature usually indicates cooling system
failure whereas a slow rise usually indicates insufficient
cooling capacity. When the temperature drops below the major
threshold, this failure will clear.
Critical temperature threshold: This failure indicates that the
incoming ambient air temperature is above the critical threshold
temperature. Either the cooling system in the building has
failed, or it has insufficient cooling capacity for the
equipment in the room. A rapid rise in temperature usually
indicates cooling system failure whereas a slow rise usually
indicates insufficient cooling capacity. When the temperature
drops below the critical threshold, this failure will clear. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
aviciBayBreakerNotification |
1.3.6.1.4.1.2474.1.4.2.0.3 |
A Breaker notification is sent when the specified breaker has
tripped or been manually reset. The breaker may have tripped
due to a short circuit, excessive current being drawn, or by
an excessively high incoming voltage. This failure is cleared
when the breaker is manually reset. If the breaker is manually
opened, no trap will be sent. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
aviciBayMultiFanFailures |
1.3.6.1.4.1.2474.1.4.2.0.4 |
Two or more fans have failed in this bay. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
aviciBayMIBCompliance |
1.3.6.1.4.1.2474.1.4.4.1.1 |
The compliance statement for the aviciBay. |
Status: current |
Access: read-only |
MODULE-COMPLIANCE |
|
|
|
aviciBayGroup |
1.3.6.1.4.1.2474.1.4.4.2.1 |
Objects for the bay. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
aviciBayControllerGroup |
1.3.6.1.4.1.2474.1.4.4.2.2 |
Objects for the bayController. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
aviciBayCentralOfficeGroup |
1.3.6.1.4.1.2474.1.4.4.2.3 |
Objects for the central office. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
aviciBayNotificationGroup |
1.3.6.1.4.1.2474.1.4.4.2.4 |
Notifications for the bay. |
Status: current |
Access: read-only |
NOTIFICATION-GROUP |
|
|
|