AVICI-SONET-MIB
File:
AVICI-SONET-MIB.mib (54389 bytes)
Imported modules
Imported symbols
Defined Types
AviciSonetMediumEntry |
|
SEQUENCE |
|
|
|
|
aviciSonetMediumFramingType |
INTEGER |
|
|
aviciSonetMediumLoopbackMode |
INTEGER |
|
|
aviciSonetMediumClockSource |
INTEGER |
|
AviciSonetSectionEntry |
|
SEQUENCE |
|
|
|
|
aviciSonetTxSectionJ0 |
DisplayString |
|
|
aviciSonetSectionThresholdES |
Unsigned32 |
|
|
aviciSonetSectionThresholdSES |
Unsigned32 |
|
|
aviciSonetSectionThresholdSEFS |
Unsigned32 |
|
|
aviciSonetSectionThresholdCV |
Unsigned32 |
|
|
aviciSonetSectionEventEnable |
Integer32 |
|
|
aviciSonetSectionEventStatus |
Integer32 |
|
|
aviciSonetSectionEventIndex |
Integer32 |
|
|
aviciSonetSectionCurrentFailures |
Integer32 |
|
|
aviciSonetRxSectionJ0 |
DisplayString |
|
AviciSonetLineEntry |
|
SEQUENCE |
|
|
|
|
aviciSonetLineS1 |
Integer32 |
|
|
aviciSonetLineAPS |
Integer32 |
|
|
aviciSonetLineThresholdES |
Unsigned32 |
|
|
aviciSonetLineThresholdSES |
Unsigned32 |
|
|
aviciSonetLineThresholdCV |
Unsigned32 |
|
|
aviciSonetLineThresholdUAS |
Unsigned32 |
|
|
aviciSonetLineEventEnable |
Integer32 |
|
|
aviciSonetLineEventStatus |
Integer32 |
|
|
aviciSonetLineEventIndex |
Integer32 |
|
|
aviciSonetLineCurrentFailures |
Integer32 |
|
AviciSonetFarEndLineEntry |
|
SEQUENCE |
|
|
|
|
aviciSonetFarEndLineThresholdES |
Unsigned32 |
|
|
aviciSonetFarEndLineThresholdSES |
Unsigned32 |
|
|
aviciSonetFarEndLineThresholdCV |
Unsigned32 |
|
|
aviciSonetFarEndLineThresholdUAS |
Unsigned32 |
|
|
aviciSonetFarEndLineEventEnable |
Integer32 |
|
|
aviciSonetFarEndLineEventStatus |
Integer32 |
|
|
aviciSonetFarEndLineEventIndex |
Integer32 |
|
AviciSonetPathEntry |
|
SEQUENCE |
|
|
|
|
aviciSonetPathC2 |
Integer32 |
|
|
aviciSonetPathTxTrace |
DisplayString |
|
|
aviciSonetPathRxTrace |
DisplayString |
|
|
aviciSonetPathThresholdES |
Unsigned32 |
|
|
aviciSonetPathThresholdSES |
Unsigned32 |
|
|
aviciSonetPathThresholdCV |
Unsigned32 |
|
|
aviciSonetPathThresholdUAS |
Unsigned32 |
|
|
aviciSonetPathEventEnable |
Integer32 |
|
|
aviciSonetPathEventStatus |
Integer32 |
|
|
aviciSonetPathEventIndex |
Integer32 |
|
|
aviciSonetPathCurrentFailures |
Integer32 |
|
AviciSonetFarEndPathEntry |
|
SEQUENCE |
|
|
|
|
aviciSonetFarEndPathThresholdES |
Unsigned32 |
|
|
aviciSonetFarEndPathThresholdSES |
Unsigned32 |
|
|
aviciSonetFarEndPathThresholdCV |
Unsigned32 |
|
|
aviciSonetFarEndPathThresholdUAS |
Unsigned32 |
|
|
aviciSonetFarEndPathEventEnable |
Integer32 |
|
|
aviciSonetFarEndPathEventStatus |
Integer32 |
|
|
aviciSonetFarEndPathEventIndex |
Integer32 |
|
Defined Values
aviciSonetMediumEntry |
1.3.6.1.4.1.2474.1.3.1.1.1 |
An entry in the Avici SONET/SDH medium table. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
AviciSonetMediumEntry |
|
|
aviciSonetMediumFramingType |
1.3.6.1.4.1.2474.1.3.1.1.1.1 |
This variable specifies the type of framing used by the interface. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
sonet(1), sdh(2) |
|
aviciSonetMediumLoopbackMode |
1.3.6.1.4.1.2474.1.3.1.1.1.2 |
This variable specifies whether the interface is in a loopback mode
of operation. Furthermore, if the interface is in a loopback mode of
operation, then this variable specifies the type of loopback being
applied to the interface. A line loopback is an externally applied
loopback. For example, the SONET/SDH MUX can provide a loopback for the
interface. This type of loopback is a line loopback. An internal
loopback is an internally applied loopback. Typically the interface's
PHY controller provides an interface's internal loopback. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
none(1), line(2), internal(3) |
|
aviciSonetMediumClockSource |
1.3.6.1.4.1.2474.1.3.1.1.1.3 |
This variable specifies the origin of the clock being used by the
interface's PHY controller. If the interface is using the line as its
clock source, then it derives the clock from the inbound signal. If the
interface is using the interface as its clock source, then it derives
the clock internally. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
line(1), interface(2) |
|
aviciSonetSectionEntry |
1.3.6.1.4.1.2474.1.3.1.2.1 |
An entry in the Avici SONET/SDH section table. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
AviciSonetSectionEntry |
|
|
aviciSonetTxSectionJ0 |
1.3.6.1.4.1.2474.1.3.1.2.1.1 |
This variable specifies the value to which the section entity sets the
J0 byte of the SONET/SDH section overhead for all outbound frames. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..16) |
|
aviciSonetSectionThresholdES |
1.3.6.1.4.1.2474.1.3.1.2.1.2 |
This variable specifies a threshold for the number of Errored Seconds
encountered by the SONET/SDH section entity in the current fifteen
minute interval. If the value of sonetSectionCurrentESs becomes greater
than or equal to this value in the current fifteen minute interval, then
a single aviciSonetSectionEvent notification will be generated. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
1..900 |
|
aviciSonetSectionThresholdSES |
1.3.6.1.4.1.2474.1.3.1.2.1.3 |
This variable specifies a threshold for the number of Severely Errored
Seconds encountered by the SONET/SDH section entity in the current
fifteen minute interval. If the value of sonetSectionCurrentSESs becomes
greater than or equal to this value in the current fifteen minute interval,
then a single aviciSonetSectionEvent notification will be generated. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
1..900 |
|
aviciSonetSectionThresholdSEFS |
1.3.6.1.4.1.2474.1.3.1.2.1.4 |
This variable specifies a threshold for the number of Severely Errored
Framing Seconds encountered by the SONET/SDH section entity in the current
fifteen minute interval. If the value of sonetSectionCurrentSEFSs becomes
greater than or equal to this value in the current fifteen minute
interval, then a single aviciSonetSectionEvent notification will be
generated. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
1..900 |
|
aviciSonetSectionThresholdCV |
1.3.6.1.4.1.2474.1.3.1.2.1.5 |
This variable specifies a threshold for the number of Coding Violations
encountered by the SONET/SDH section entity in the current fifteen minute
interval. If the value of sonetSectionCurrentCVs becomes greater
than or equal to this value in the current fifteen minute interval, then
a single aviciSonetSectionEvent notification will be generated. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
1..4294967295 |
|
aviciSonetSectionEventEnable |
1.3.6.1.4.1.2474.1.3.1.2.1.6 |
This variable specifies the type of events that will be generated for
this corresponding SONET/SDH section entity. The value represents a
vector of bits, each controlling a unique event:
- Bit 0 Rising threshold alarm, sonetSectionCurrentESs.
- Bit 1 Rising threshold alarm, sonetSectionCurrentSESs.
- Bit 2 Rising threshold alarm, sonetSectionCurrentSEFSs.
- Bit 3 Rising threshold alarm, sonetSectionCurrentCVs.
- Bit 4 Reserved.
- Bit 5 LOS failure indication.
- Bit 6 LOS failure cleared.
- Bit 7 LOF failure indication.
- Bit 8 LOF failure cleared.
|
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..511 |
|
aviciSonetSectionEventStatus |
1.3.6.1.4.1.2474.1.3.1.2.1.7 |
This variable specifies which events have occurred in the current 15
minute interval. The value represents a vector of bits, each specifying
a unique event:
- Bit 0 Rising threshold alarm, sonetSectionCurrentESs.
- Bit 1 Rising threshold alarm, sonetSectionCurrentSESs.
- Bit 2 Rising threshold alarm, sonetSectionCurrentSEFSs.
- Bit 3 Rising threshold alarm, sonetSectionCurrentCVs.
- Bit 4 Reserved.
- Bit 5 LOS failure indication.
- Bit 6 LOS failure cleared.
- Bit 7 LOF failure indication.
- Bit 8 LOF failure cleared.
|
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..511 |
|
aviciSonetSectionEventIndex |
1.3.6.1.4.1.2474.1.3.1.2.1.8 |
The index of the eventEntry that is used when one of the following
events concerning the section entity has occurred:
- The value sonetSectionCurrentESs has crossed the threshold
specified by aviciSonetSectionThresholdES.
- The value sonetSectionCurrentSESs has crossed the threshold
specified by aviciSonetSectionThresholdSES.
- The value sonetSectionCurrentSEFSs has crossed the threshold
specified by aviciSonetSectionThresholdSEFS.
- The value sonetSectionCurrentCVs has crossed the threshold
specified by aviciSonetSectionThresholdCV.
- The SONET/SDH section entity has experienced a loss of signal
(LOS) failure.
- The SONET/SDH section entity has cleared the LOS failure
condition.
- The SONET/SDH section entity has experienced a loss of frame
(LOF) failure.
- The SONET/SDH section entity has cleared the LOF failure
condition.
The eventEntry identified by a particular value of this index is the
same as identified by the same value of the eventindex object. If
there is no corresponding entry in the eventTable, then no association
exists. In particular, if this value is zero, no associated event will
be generated, as zero is not a valid event index. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..65535 |
|
aviciSonetSectionCurrentFailures |
1.3.6.1.4.1.2474.1.3.1.2.1.9 |
This variable specifies which failures have occurred. A value of zero
means no failures have occurred. The value represents a vector of bits,
each specifying a unique failure:
- Bit 0 No Failure
- Bit 1 LOS failure.
- Bit 2 LOF failure indication.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..511 |
|
aviciSonetRxSectionJ0 |
1.3.6.1.4.1.2474.1.3.1.2.1.10 |
This variable specifies the value to which the section entity sets the
J0 byte of the SONET/SDH section overhead for the last frame received
by this interface. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..16) |
|
aviciSonetLineEntry |
1.3.6.1.4.1.2474.1.3.1.3.1 |
An entry in the Avici SONET/SDH line table. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
AviciSonetLineEntry |
|
|
aviciSonetLineS1 |
1.3.6.1.4.1.2474.1.3.1.3.1.1 |
This variable specifies the value to which the line entity sets the
S1 byte of the SONET/SDH line overhead for all outbound frames. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..255 |
|
aviciSonetLineAPS |
1.3.6.1.4.1.2474.1.3.1.3.1.2 |
This variable specifies the value to which the line entity sets the
K1 and K2 bytes of the SONET/SDH line overhead for all outbound frames. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..65535 |
|
aviciSonetLineThresholdES |
1.3.6.1.4.1.2474.1.3.1.3.1.3 |
This variable specifies a threshold for the number of Errored Seconds
encountered by the SONET/SDH line entity in the current fifteen minute
interval. If the value of sonetLineCurrentESs becomes greater
than or equal to this value in the current fifteen minute interval, then
a single aviciSonetLineEvent notification will be generated. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
1..900 |
|
aviciSonetLineThresholdSES |
1.3.6.1.4.1.2474.1.3.1.3.1.4 |
This variable specifies a threshold for the number of Severely Errored
Seconds encountered by the SONET/SDH line entity in the current fifteen
minute interval. If the value of sonetLineCurrentSESs becomes greater
than or equal to this value in the current fifteen minute interval, then
a single aviciSonetLineEvent notification will be generated. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
1..900 |
|
aviciSonetLineThresholdCV |
1.3.6.1.4.1.2474.1.3.1.3.1.5 |
This variable specifies a threshold for the number of Coding Violations
encountered by the SONET/SDH line entity in the current fifteen minute
interval. If the value of sonetLineCurrentCVs becomes greater
than or equal to this value in the current fifteen minute interval, then
a single aviciSonetLineEvent notification will be generated. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
1..4294967295 |
|
aviciSonetLineThresholdUAS |
1.3.6.1.4.1.2474.1.3.1.3.1.6 |
This variable specifies a threshold for the number of Unavailable
Seconds encountered by a SONET/SDH line entity in the current fifteen
minute interval. If the value of sonetLineCurrentUASs becomes greater
than or equal to this value in the current fifteen minute interval, then
a single aviciSonetLineEvent notification will be generated. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
1..900 |
|
aviciSonetLineEventEnable |
1.3.6.1.4.1.2474.1.3.1.3.1.7 |
This variable specifies the type of events that will be generated for
this corresponding SONET/SDH line entity. The value represents a
vector of bits, each controlling a unique event:
- Bit 0 Rising threshold alarm, sonetSectionCurrentESs.
- Bit 1 Rising threshold alarm, sonetSectionCurrentSESs.
- Bit 2 Reserved.
- Bit 3 Rising threshold alarm, sonetSectionCurrentCVs.
- Bit 4 Rising threshold alarm, sonetSectionCurrentUASs.
- Bit 5 AIS failure indication.
- Bit 6 AIS failure cleared.
- Bit 7 RFI indication.
- Bit 8 RFI cleared.
|
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..511 |
|
aviciSonetLineEventStatus |
1.3.6.1.4.1.2474.1.3.1.3.1.8 |
This variable specifies which events have occurred in the current 15
minute interval. The value represents a vector of bits, each specifying
a unique event:
- Bit 0 Rising threshold alarm, sonetLineCurrentESs.
- Bit 1 Rising threshold alarm, sonetLineCurrentSESs.
- Bit 2 Reserved.
- Bit 3 Rising threshold alarm, sonetLineCurrentCVs.
- Bit 4 Rising threshold alarm, sonetLineCurrentUASs.
- Bit 5 AIS failure indication.
- Bit 6 AIS failure cleared.
- Bit 7 RFI indication.
- Bit 8 RFI cleared.
|
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..511 |
|
aviciSonetLineEventIndex |
1.3.6.1.4.1.2474.1.3.1.3.1.9 |
The index of the eventEntry that is used when one of the following
events concerning the line entity has occurred:
- The value sonetLineCurrentESs has crossed the threshold
specified by aviciSonetLineThresholdES.
- The value sonetLineCurrentSESs has crossed the threshold
specified by aviciSonetLineThresholdSES.
- The value sonetLineCurrentCVs has crossed the threshold
specified by aviciSonetLineThresholdCV.
- The value sonetLineCurrentUASs has crossed the threshold
specified by aviciSonetLineThresholdUAS.
- The SONET/SDH line entity has experienced an alarm indication
signal (AIS) failure.
- The SONET/SDH line entity has cleared the AIS failure condition.
- The SONET/SDH line entity has experienced a remote failure
indication (RFI).
- The SONET/SDH line entity has cleared the RFI condition.
The eventEntry identified by a particular value of this index is the
same as identified by the same value of the eventindex object. If
there is no corresponding entry in the eventTable, then no association
exists. In particular, if this value is zero, no associated event will
be generated, as zero is not a valid event index. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..65535 |
|
aviciSonetLineCurrentFailures |
1.3.6.1.4.1.2474.1.3.1.3.1.10 |
This variable specifies which failures have occurred. A value of zero
means no failures have occurred. The value represents a vector of bits,
each specifying a unique failure:
- Bit 0 No Failures
- Bit 1 AIS failure indication.
- Bit 2 RFI indication.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..511 |
|
aviciSonetFarEndLineEntry |
1.3.6.1.4.1.2474.1.3.1.4.1 |
An entry in the Avici SONET/SDH far end line table. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
AviciSonetFarEndLineEntry |
|
|
aviciSonetFarEndLineThresholdES |
1.3.6.1.4.1.2474.1.3.1.4.1.1 |
This variable specifies a threshold for the number of Far End Errored
Seconds encountered by the SONET/SDH line entity in the current fifteen
minute interval. If the value of sonetFarEndLineCurrentESs becomes
greater than or equal to this value in the current fifteen minute
interval, then a single aviciSonetFarEndLineEvent notification will
be generated. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
1..900 |
|
aviciSonetFarEndLineThresholdSES |
1.3.6.1.4.1.2474.1.3.1.4.1.2 |
This variable specifies a threshold for the number of Far End Severely
Errored Seconds encountered by the SONET/SDH line entity in the current
fifteen minute interval. If the value of sonetFarEndLineCurrentSESs
becomes greater than or equal to this value in the current fifteen minute
interval, then a single aviciSonetFarEndLineEvent notification will
be generated. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
1..900 |
|
aviciSonetFarEndLineThresholdCV |
1.3.6.1.4.1.2474.1.3.1.4.1.3 |
This variable specifies a threshold for the number of Far End Coding
Violations encountered by the SONET/SDH line entity in the current
fifteen minute interval. If the value of sonetFarEndLineCurrentCVs
becomes greater than or equal to this value in the current fifteen
minute interval, then a single aviciSonetFarEndLineEvent notification
will be generated. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
1..4294967295 |
|
aviciSonetFarEndLineThresholdUAS |
1.3.6.1.4.1.2474.1.3.1.4.1.4 |
This variable specifies a threshold for the number of Far End
Unavailable Seconds encountered by a SONET/SDH line entity in the
current fifteen minute interval. If the value of
sonetFarEndLineCurrentUASs becomes greater than or equal to this
value in the current fifteen minute interval, then a single
aviciSonetFarEndLineEvent notification will be generated. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
1..900 |
|
aviciSonetFarEndLineEventEnable |
1.3.6.1.4.1.2474.1.3.1.4.1.5 |
This variable specifies the type of events that will be generated for
this corresponding SONET/SDH far-end line entity. The value represents
a vector of bits, each controlling a unique event:
- Bit 0 Rising threshold alarm, sonetSectionCurrentESs.
- Bit 1 Rising threshold alarm, sonetSectionCurrentSESs.
- Bit 2 Reserved.
- Bit 3 Rising threshold alarm, sonetSectionCurrentCVs.
- Bit 4 Rising threshold alarm, sonetSectionCurrentUASs.
|
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..32 |
|
aviciSonetFarEndLineEventStatus |
1.3.6.1.4.1.2474.1.3.1.4.1.6 |
This variable specifies which events have occurred in the current 15
minute interval. The value represents a vector of bits, each specifying
a unique event:
- Bit 0 Rising threshold alarm, sonetFarEndLineCurrentESs.
- Bit 1 Rising threshold alarm, sonetFarEndLineCurrentSESs.
- Bit 2 Reserved.
- Bit 3 Rising threshold alarm, sonetFarEndLineCurrentCVs.
- Bit 4 Rising threshold alarm, sonetFarEndLineCurrentUASs.
|
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..32 |
|
aviciSonetFarEndLineEventIndex |
1.3.6.1.4.1.2474.1.3.1.4.1.7 |
The index of the eventEntry that is used when one of the following
events concerning the far-end line entity has occurred:
- The value sonetFarEndLineCurrentESs has crossed the threshold
specified by aviciSonetFarEndLineThresholdES.
- The value sonetFarEndLineCurrentSESs has crossed the threshold
specified by aviciSonetFarEndLineThresholdSES.
- The value sonetFarEndLineCurrentCVs has crossed the threshold
specified by aviciSonetFarEndLineThresholdCV.
- The value sonetFarEndLineCurrentUASs has crossed the threshold
specified by aviciSonetFarEndLineThresholdUAS.
The eventEntry identified by a particular value of this index is the
same as identified by the same value of the eventindex object. If
there is no corresponding entry in the eventTable, then no association
exists. In particular, if this value is zero, no associated event will
be generated, as zero is not a valid event index. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..65535 |
|
aviciSonetPathEntry |
1.3.6.1.4.1.2474.1.3.1.5.1 |
An entry in the Avici SONET/SDH path table. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
AviciSonetPathEntry |
|
|
aviciSonetPathC2 |
1.3.6.1.4.1.2474.1.3.1.5.1.1 |
This variable specifies the value to which the path entity sets the
C2 byte of the SONET/SDH path overhead for all outbound frames. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..255 |
|
aviciSonetPathTxTrace |
1.3.6.1.4.1.2474.1.3.1.5.1.2 |
This variable specifies the value to which the path entity sets the
trace field of the SONET/SDH path overhead for all outbound frames. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(64) |
|
aviciSonetPathRxTrace |
1.3.6.1.4.1.2474.1.3.1.5.1.3 |
This variable specifies the value of the trace field of the SONET/SDH
path overhead for the last frame received by this interface. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(64) |
|
aviciSonetPathThresholdES |
1.3.6.1.4.1.2474.1.3.1.5.1.4 |
This variable specifies a threshold for the number of Errored Seconds
encountered by the SONET/SDH path entity in the current fifteen minute
interval. If the value of sonetPathCurrentESs becomes greater
than or equal to this value in the current fifteen minute interval, then
a single aviciSonetPathEvent notification will be generated. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
1..900 |
|
aviciSonetPathThresholdSES |
1.3.6.1.4.1.2474.1.3.1.5.1.5 |
This variable specifies a threshold for the number of Severely Errored
Seconds encountered by the SONET/SDH path entity in the current fifteen
minute interval. If the value of sonetPathCurrentSESs becomes greater
than or equal to this value in the current fifteen minute interval, then
a single aviciSonetPathEvent notification will be generated. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
1..900 |
|
aviciSonetPathThresholdCV |
1.3.6.1.4.1.2474.1.3.1.5.1.6 |
This variable specifies a threshold for the number of Coding Violations
encountered by the SONET/SDH path entity in the current fifteen minute
interval. If the value of sonetPathCurrentCVs becomes greater
than or equal to this value in the current fifteen minute interval, then
a single aviciSonetPathEvent notification will be generated. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
1..4294967295 |
|
aviciSonetPathThresholdUAS |
1.3.6.1.4.1.2474.1.3.1.5.1.7 |
This variable specifies a threshold for the number of Unavailable
Seconds encountered by a SONET/SDH path entity in the current fifteen
minute interval. If the value of sonetPathCurrentUASs becomes greater
than or equal to this value in the current fifteen minute interval, then
a single aviciSonetPathEvent notification will be generated. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
1..900 |
|
aviciSonetPathEventEnable |
1.3.6.1.4.1.2474.1.3.1.5.1.8 |
This variable specifies the type of events that will be generated for
this corresponding SONET/SDH path entity. The value represents a
vector of bits, each controlling a unique event:
- Bit 0 Rising threshold alarm, sonetSectionCurrentESs.
- Bit 1 Rising threshold alarm, sonetSectionCurrentSESs.
- Bit 2 Reserved.
- Bit 3 Rising threshold alarm, sonetSectionCurrentCVs.
- Bit 4 Rising threshold alarm, sonetSectionCurrentUASs.
- Bit 5 LOP failure indication.
- Bit 6 LOP failure cleared.
- Bit 7 AIS failure indication.
- Bit 8 AIS failure cleared.
- Bit 9 RFI indication.
- Bit 10 RFI cleared.
- Bit 11 UNEQ failure indication.
- Bit 12 UNEQ failure cleared.
- Bit 13 PLM failure indication.
- Bit 14 PLM failure cleared.
|
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..32767 |
|
aviciSonetPathEventStatus |
1.3.6.1.4.1.2474.1.3.1.5.1.9 |
This variable specifies which events have occurred in the current 15
minute interval. The value represents a vector of bits, each specifying
a unique event:
- Bit 0 Rising threshold alarm, sonetPathCurrentESs.
- Bit 1 Rising threshold alarm, sonetPathCurrentSESs.
- Bit 2 Reserved.
- Bit 3 Rising threshold alarm, sonetPathCurrentCVs.
- Bit 4 Rising threshold alarm, sonetPathCurrentUASs.
- Bit 5 LOP failure indication.
- Bit 6 LOP failure cleared.
- Bit 7 AIS failure indication.
- Bit 8 AIS failure cleared.
- Bit 9 RFI indication.
- Bit 10 RFI cleared.
- Bit 11 UNEQ failure indication.
- Bit 12 UNEQ failure cleared.
- Bit 13 PLM failure indication.
- Bit 14 PLM failure cleared.
|
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..32767 |
|
aviciSonetPathEventIndex |
1.3.6.1.4.1.2474.1.3.1.5.1.10 |
The index of the eventEntry that is used when one of the following
events concerning the path entity has occurred:
- The value sonetPathCurrentESs has crossed the threshold
specified by aviciSonetPathThresholdES.
- The value sonetPathCurrentSESs has crossed the threshold
specified by aviciSonetPathThresholdSES.
- The value sonetPathCurrentCVs has crossed the threshold
specified by aviciSonetPathThresholdCV.
- The value sonetPathCurrentUASs has crossed the threshold
specified by aviciSonetPathThresholdUAS.
- The SONET/SDH path entity has experienced a loss of pointer
(LOP) failure.
- The SONET/SDH path entity has cleared the LOP failure condition.
- The SONET/SDH path entity has experienced an alarm indication signal
(AIS) failure.
- The SONET/SDH path entity has cleared the AIS failure condition.
- The SONET/SDH path entity has experienced a remote defect indication
(RFI).
- The SONET/SDH path entity has cleared the RFI condition.
- The SONET/SDH path entity has experienced an unequipped failure
(UNEQ) failure.
- The SONET/SDH path entity has cleared the UNEQ failure condition.
- The SONET/SDH path entity has experienced a path label mismatch
(PLM) failure.
- The SONET/SDH path entity has cleared the PLM failure condition.
The eventEntry identified by a particular value of this index is the
same as identified by the same value of the eventindex object. If
there is no corresponding entry in the eventTable, then no association
exists. In particular, if this value is zero, no associated event will
be generated, as zero is not a valid event index. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..65535 |
|
aviciSonetPathCurrentFailures |
1.3.6.1.4.1.2474.1.3.1.5.1.11 |
This variable specifies which failures have occurred. A value of zero
means no failures have occurred. The value represents a vector of bits,
each specifying a unique failure:
- Bit 0 No Failures
- Bit 1 LOP failure indication.
- Bit 2 AIS failure indication.
- Bit 3 RFI indication.
- Bit 4 UNEQ failure indication.
- Bit 5 PLM failure indication.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..511 |
|
aviciSonetFarEndPathEntry |
1.3.6.1.4.1.2474.1.3.1.6.1 |
An entry in the Avici SONET/SDH far end path table. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
AviciSonetFarEndPathEntry |
|
|
aviciSonetFarEndPathThresholdES |
1.3.6.1.4.1.2474.1.3.1.6.1.1 |
This variable specifies a threshold for the number of Far End Errored
Seconds encountered by the SONET/SDH path entity in the current 15 minute
interval. If the value of sonetFarEndPathCurrentESs becomes greater
than or equal to this value in the current fifteen minute interval, then
a single aviciSonetFarEndPathEvent notification will be generated. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
1..900 |
|
aviciSonetFarEndPathThresholdSES |
1.3.6.1.4.1.2474.1.3.1.6.1.2 |
This variable specifies a threshold for the number of Far End Severely
Errored Seconds encountered by the SONET/SDH path entity in the current
fifteen minute interval. If the value of sonetFarEndPathCurrentSESs
becomes greater than or equal to this value in the current fifteen minute
interval, then a single aviciSonetFarEndPathEvent notification will be
generated. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
1..900 |
|
aviciSonetFarEndPathThresholdCV |
1.3.6.1.4.1.2474.1.3.1.6.1.3 |
This variable specifies a threshold for the number of Far End Coding
Violations encountered by the SONET/SDH path entity in the current
fifteen minute interval. If the value of sonetFarEndPathCurrentCVs
becomes greater than or equal to this value in the current fifteen
minute interval, then a single aviciSonetFarEndPathEvent notification
will be generated. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
1..4294967295 |
|
aviciSonetFarEndPathThresholdUAS |
1.3.6.1.4.1.2474.1.3.1.6.1.4 |
This variable specifies a threshold for the number of Far End
Unavailable Seconds encountered by a SONET/SDH path entity in the
current fifteen minute interval. If the value of
sonetFarEndPathCurrentUASs becomes greater than or equal to this
value in the current fifteen minute interval, then a single
aviciSonetFarEndPathEvent notification will be generated. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
1..900 |
|
aviciSonetFarEndPathEventEnable |
1.3.6.1.4.1.2474.1.3.1.6.1.5 |
This variable specifies the type of events that will be generated for
this corresponding SONET/SDH far-end path entity. The value represents a
vector of bits, each controlling a unique event:
- Bit 0 Rising threshold alarm, sonetSectionCurrentESs.
- Bit 1 Rising threshold alarm, sonetSectionCurrentSESs.
- Bit 2 Reserved.
- Bit 3 Rising threshold alarm, sonetSectionCurrentCVs.
- Bit 4 Rising threshold alarm, sonetSectionCurrentUASs.
|
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..32 |
|
aviciSonetFarEndPathEventStatus |
1.3.6.1.4.1.2474.1.3.1.6.1.6 |
This variable specifies which events have occurred in the current 15
minute interval. The value represents a vector of bits, each specifying
a unique event:
- Bit 0 Rising threshold alarm, sonetFarEndPathCurrentESs.
- Bit 1 Rising threshold alarm, sonetFarEndPathCurrentSESs.
- Bit 2 Reserved.
- Bit 3 Rising threshold alarm, sonetFarEndPathCurrentCVs.
- Bit 4 Rising threshold alarm, sonetFarEndPathCurrentUASs.
|
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..32 |
|
aviciSonetFarEndPathEventIndex |
1.3.6.1.4.1.2474.1.3.1.6.1.7 |
The index of the eventEntry that is used when one of the following
events concerning the far-end path entity has occurred:
- The value sonetPathCurrentESs has crossed the threshold
specified by aviciSonetPathThresholdES.
- The value sonetPathCurrentSESs has crossed the threshold
specified by aviciSonetPathThresholdSES.
- The value sonetPathCurrentCVs has crossed the threshold
specified by aviciSonetPathThresholdCV.
- The value sonetPathCurrentUASs has crossed the threshold
specified by aviciSonetPathThresholdUAS.
The eventEntry identified by a particular value of this index is the
same as identified by the same value of the eventindex object. If
there is no corresponding entry in the eventTable, then no association
exists. In particular, if this value is zero, no associated event will
be generated, as zero is not a valid event index. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..65535 |
|
aviciSonetSectionEvent |
1.3.6.1.4.1.2474.1.3.2.0.1 |
An interfaces generates this notification when one of the
following events occur:
1) One of the performance counters maintained by the section entity
associated with a SONET/SDH interface has crossed an established
threshold.
2) The section entity associated with a SONET/SDH interface
experiences a failure.
3) The section entity associated with a SONET/SDH interface
clears a failure condition.
The interface only generates a notification for one of these events
if the corresponding enable bit is set to one in the instance of
aviciSonetSectionEventEnable associated with the interface. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
aviciSonetLineEvent |
1.3.6.1.4.1.2474.1.3.2.0.2 |
An interfaces generates this notification when one of the
following events occur:
1) One of the performance counters maintained by the line entity
associated with a SONET/SDH interface has crossed an established
threshold.
2) The line entity associated with a SONET/SDH interface
experiences a failure.
3) The line entity associated with a SONET/SDH interface
clears a failure condition.
The interface only generates a notification for one of these events
if the corresponding enable bit is set to one in the instance of
aviciSonetLineEventEnable associated with the interface. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
aviciSonetFarEndLineEvent |
1.3.6.1.4.1.2474.1.3.2.0.3 |
An interfaces generates this notification when one of the
following events occur:
1) One of the performance counters maintained by the far-end line
entity associated with a SONET/SDH interface has crossed an
established threshold.
2) The far-end line entity associated with a SONET/SDH interface
experiences a failure.
3) The far-end line entity associated with a SONET/SDH interface
clears a failure condition.
The interface only generates a notification for one of these events
if the corresponding enable bit is set to one in the instance of
aviciSonetFarEndLineEventEnable associated with the interface. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
aviciSonetPathEvent |
1.3.6.1.4.1.2474.1.3.2.0.4 |
An interfaces generates this notification when one of the
following events occur:
1) One of the performance counters maintained by the path entity
associated with a SONET/SDH interface has crossed an established
threshold.
2) The path entity associated with a SONET/SDH interface
experiences a failure.
3) The path entity associated with a SONET/SDH interface
clears a failure condition.
The interface only generates a notification for one of these events
if the corresponding enable bit is set to one in the instance of
aviciSonetPathEventEnable associated with the interface. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
aviciSonetFarEndPathEvent |
1.3.6.1.4.1.2474.1.3.2.0.5 |
An interfaces generates this notification when one of the
following events occur:
1) One of the performance counters maintained by the far-end path
entity associated with a SONET/SDH interface has crossed an
established threshold.
2) The far-end path entity associated with a SONET/SDH interface
experiences a failure.
3) The far-end path entity associated with a SONET/SDH interface
clears a failure condition.
The interface only generates a notification for one of these events
if the corresponding enable bit is set to one in the instance of
aviciSonetFarEndPathEventEnable associated with the interface. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
aviciSonetMIBCompliance |
1.3.6.1.4.1.2474.1.3.3.1.1 |
The compliance statement for aviciSonet. |
Status: current |
Access: read-create |
MODULE-COMPLIANCE |
|
|
|
aviciSonetGroup |
1.3.6.1.4.1.2474.1.3.3.2.1 |
Objects for the SONET layer. |
Status: current |
Access: read-create |
OBJECT-GROUP |
|
|
|
aviciSonetPathGroup |
1.3.6.1.4.1.2474.1.3.3.2.2 |
Objects for the SONET Path layer. |
Status: current |
Access: read-create |
OBJECT-GROUP |
|
|
|
aviciSonetNotificationGroup |
1.3.6.1.4.1.2474.1.3.3.2.3 |
Notifications for SONET events. |
Status: current |
Access: read-create |
NOTIFICATION-GROUP |
|
|
|