BCS-IDENT-MIB

File: BCS-IDENT-MIB.mib (35095 bytes)

Imported modules

SNMPv2-TC SNMPv2-SMI

Imported symbols

DisplayString OBJECT-TYPE MODULE-IDENTITY

Defined Types

EntryStatus  
INTEGER valid(1), createRequest(2), underCreation(3), invalid(4)    

IdentIfExtensionEntry  
SEQUENCE    
  identIfExtensionIndex INTEGER
  identIfSerialNumber DisplayString
  identIfHardwareVersion DisplayString
  identIfHardwareFeatures DisplayString
  identIfInventoryCode DisplayString
  identIfFirmwareVersion1 DisplayString
  identIfFirmwareVersion2 DisplayString
  identIfFirmwareVersion3 DisplayString
  identIfFirmwareVersion4 DisplayString
  identIfSlotId INTEGER
  identIfCommand INTEGER
  identIfAdministrativeState INTEGER
  identIfOperationalState INTEGER
  identIfAlarmStatus INTEGER
  identIfAvailabilityStatus INTEGER
  identIfSpecific OBJECT IDENTIFIER
  identIfEntryStatus EntryStatus

Defined Values

gi 1.3.6.1.4.1.1166
The SMIv2 MIB module for the MOTOROLA BCS common ident objects. The MIB Tree for this is shown below.
MODULE-IDENTITY    

giproducts 1.3.6.1.4.1.1166.1
OBJECT IDENTIFIER    

acc4000d 1.3.6.1.4.1.1166.1.1
OBJECT IDENTIFIER    

anicd 1.3.6.1.4.1.1166.1.2
OBJECT IDENTIFIER    

item1000 1.3.6.1.4.1.1166.1.4
OBJECT IDENTIFIER    

irt1000 1.3.6.1.4.1.1166.1.5
OBJECT IDENTIFIER    

nc1500 1.3.6.1.4.1.1166.1.6
OBJECT IDENTIFIER    

om1000 1.3.6.1.4.1.1166.1.7
OBJECT IDENTIFIER    

im1000 1.3.6.1.4.1.1166.1.8
OBJECT IDENTIFIER    

mps 1.3.6.1.4.1.1166.1.9
OBJECT IDENTIFIER    

rpd1000 1.3.6.1.4.1.1166.1.10
OBJECT IDENTIFIER    

acpStatus 1.3.6.1.4.1.1166.1.11
OBJECT IDENTIFIER    

heartbeat 1.3.6.1.4.1.1166.1.12
OBJECT IDENTIFIER    

entitlementKey 1.3.6.1.4.1.1166.1.13
OBJECT IDENTIFIER    

arpd 1.3.6.1.4.1.1166.1.14
OBJECT IDENTIFIER    

svom 1.3.6.1.4.1.1166.1.15
OBJECT IDENTIFIER    

svm 1.3.6.1.4.1.1166.1.16
OBJECT IDENTIFIER    

erm 1.3.6.1.4.1.1166.1.17
OBJECT IDENTIFIER    

surfBbnh 1.3.6.1.4.1.1166.1.18
OBJECT IDENTIFIER    

sb2100 1.3.6.1.4.1.1166.1.19
OBJECT IDENTIFIER    

sb2100D 1.3.6.1.4.1.1166.1.20
OBJECT IDENTIFIER    

sb2000 1.3.6.1.4.1.1166.1.21
OBJECT IDENTIFIER    

saDANIS 1.3.6.1.4.1.1166.1.30
OBJECT IDENTIFIER    

apex 1.3.6.1.4.1.1166.1.31
OBJECT IDENTIFIER    

rem 1.3.6.1.4.1.1166.1.32
OBJECT IDENTIFIER    

mpe 1.3.6.1.4.1.1166.1.33
OBJECT IDENTIFIER    

spe 1.3.6.1.4.1.1166.1.34
OBJECT IDENTIFIER    

ne2000 1.3.6.1.4.1.1166.1.35
OBJECT IDENTIFIER    

apex1500 1.3.6.1.4.1.1166.1.36
OBJECT IDENTIFIER    

agb 1.3.6.1.4.1.1166.1.37
OBJECT IDENTIFIER    

ne2500 1.3.6.1.4.1.1166.1.38
OBJECT IDENTIFIER    

hdd2000 1.3.6.1.4.1.1166.1.40
OBJECT IDENTIFIER    

merlin 1.3.6.1.4.1.1166.1.50
OBJECT IDENTIFIER    

rsr 1.3.6.1.4.1.1166.1.60
OBJECT IDENTIFIER    

gsrm 1.3.6.1.4.1.1166.1.61
OBJECT IDENTIFIER    

gom 1.3.6.1.4.1.1166.1.62
OBJECT IDENTIFIER    

b3 1.3.6.1.4.1.1166.1.63
OBJECT IDENTIFIER    

adm 1.3.6.1.4.1.1166.1.64
OBJECT IDENTIFIER    

sem 1.3.6.1.4.1.1166.1.70
OBJECT IDENTIFIER    

ecmg 1.3.6.1.4.1.1166.1.71
OBJECT IDENTIFIER    

bsiAdapter 1.3.6.1.4.1.1166.1.72
OBJECT IDENTIFIER    

oles 1.3.6.1.4.1.1166.1.73
OBJECT IDENTIFIER    

ne 1.3.6.1.4.1.1166.1.74
OBJECT IDENTIFIER    

tmxCommTrap 1.3.6.1.4.1.1166.1.75
OBJECT IDENTIFIER    

drmenginekskdc 1.3.6.1.4.1.1166.1.76
OBJECT IDENTIFIER    

drmenginerte 1.3.6.1.4.1.1166.1.77
OBJECT IDENTIFIER    

drmengineecmg 1.3.6.1.4.1.1166.1.78
OBJECT IDENTIFIER    

drmengineskgpkg 1.3.6.1.4.1.1166.1.79
OBJECT IDENTIFIER    

tmx 1.3.6.1.4.1.1166.1.80
OBJECT IDENTIFIER    

prs 1.3.6.1.4.1.1166.1.81
OBJECT IDENTIFIER    

se2000 1.3.6.1.4.1.1166.1.82
OBJECT IDENTIFIER    

dem 1.3.6.1.4.1.1166.1.83
OBJECT IDENTIFIER    

ncs 1.3.6.1.4.1.1166.1.84
OBJECT IDENTIFIER    

ucs 1.3.6.1.4.1.1166.1.85
OBJECT IDENTIFIER    

lmm 1.3.6.1.4.1.1166.1.86
OBJECT IDENTIFIER    

se4000 1.3.6.1.4.1.1166.1.87
OBJECT IDENTIFIER    

rc 1.3.6.1.4.1.1166.1.88
OBJECT IDENTIFIER    

netSentry 1.3.6.1.4.1.1166.1.99
OBJECT IDENTIFIER    

sdm 1.3.6.1.4.1.1166.1.100
OBJECT IDENTIFIER    

hfcEms 1.3.6.1.4.1.1166.1.101
OBJECT IDENTIFIER    

bnc 1.3.6.1.4.1.1166.1.102
OBJECT IDENTIFIER    

drmenginecm 1.3.6.1.4.1.1166.1.103
OBJECT IDENTIFIER    

stdc 1.3.6.1.4.1.1166.1.104
OBJECT IDENTIFIER    

tview 1.3.6.1.4.1.1166.1.105
OBJECT IDENTIFIER    

ponOa 1.3.6.1.4.1.1166.1.150
OBJECT IDENTIFIER    

mwtea200 1.3.6.1.4.1.1166.1.151
OBJECT IDENTIFIER    

bti 1.3.6.1.4.1.1166.1.200
OBJECT IDENTIFIER    

rfModMIB 1.3.6.1.4.1.1166.1.201
OBJECT IDENTIFIER    

btiIntMIB 1.3.6.1.4.1.1166.1.202
OBJECT IDENTIFIER    

sg4000 1.3.6.1.4.1.1166.1.203
OBJECT IDENTIFIER    

ponEm870 1.3.6.1.4.1.1166.1.210
OBJECT IDENTIFIER    

rpa 1.3.6.1.4.1.1166.1.250
OBJECT IDENTIFIER    

rpc 1.3.6.1.4.1.1166.1.251
OBJECT IDENTIFIER    

dct5000 1.3.6.1.4.1.1166.1.300
OBJECT IDENTIFIER    

dct5100 1.3.6.1.4.1.1166.1.301
OBJECT IDENTIFIER    

dct5200 1.3.6.1.4.1.1166.1.302
OBJECT IDENTIFIER    

edfaMIB 1.3.6.1.4.1.1166.1.311
OBJECT IDENTIFIER    

corvusMIB 1.3.6.1.4.1.1166.1.312
OBJECT IDENTIFIER    

oa600 1.3.6.1.4.1.1166.1.313
OBJECT IDENTIFIER    

dsr350f 1.3.6.1.4.1.1166.1.321
OBJECT IDENTIFIER    

radd6000 1.3.6.1.4.1.1166.1.400
OBJECT IDENTIFIER    

cs1000 1.3.6.1.4.1.1166.1.401
OBJECT IDENTIFIER    

kls 1.3.6.1.4.1.1166.1.402
OBJECT IDENTIFIER    

dac6000 1.3.6.1.4.1.1166.1.403
OBJECT IDENTIFIER    

sdi 1.3.6.1.4.1.1166.1.404
OBJECT IDENTIFIER    

cpms 1.3.6.1.4.1.1166.1.405
OBJECT IDENTIFIER    

ap 1.3.6.1.4.1.1166.1.406
OBJECT IDENTIFIER    

ps 1.3.6.1.4.1.1166.1.407
OBJECT IDENTIFIER    

cableCard 1.3.6.1.4.1.1166.1.350
OBJECT IDENTIFIER    

motoIPNSprodID 1.3.6.1.4.1.1166.1.450
OBJECT IDENTIFIER    

ird4500x 1.3.6.1.4.1.1166.1.610
OBJECT IDENTIFIER    

ird4520x 1.3.6.1.4.1.1166.1.620
OBJECT IDENTIFIER    

giproxies 1.3.6.1.4.1.1166.3
OBJECT IDENTIFIER    

gicommon 1.3.6.1.4.1.1166.4
OBJECT IDENTIFIER    

identity 1.3.6.1.4.1.1166.4.1
OBJECT IDENTIFIER    

state 1.3.6.1.4.1.1166.4.2
OBJECT IDENTIFIER    

traps 1.3.6.1.4.1.1166.4.3
OBJECT IDENTIFIER    

logs 1.3.6.1.4.1.1166.4.4
OBJECT IDENTIFIER    

motproxies 1.3.6.1.4.1.1166.6
OBJECT IDENTIFIER    

bcs 1.3.6.1.4.1.1166.7
OBJECT IDENTIFIER    

bcsIdent 1.3.6.1.4.1.1166.7.1
OBJECT IDENTIFIER    

bcsLogs 1.3.6.1.4.1.1166.7.4
OBJECT IDENTIFIER    

bcsSimulcryptScs 1.3.6.1.4.1.1166.7.7
OBJECT IDENTIFIER    

bcsSimulcryptMux 1.3.6.1.4.1.1166.7.8
OBJECT IDENTIFIER    

bcsSimulcrypt 1.3.6.1.4.1.1166.7.9
OBJECT IDENTIFIER    

bcsDatabase 1.3.6.1.4.1.1166.7.11
OBJECT IDENTIFIER    

bcsRedundancy 1.3.6.1.4.1.1166.7.12
OBJECT IDENTIFIER    

bcsMsgGeneration 1.3.6.1.4.1.1166.7.21
OBJECT IDENTIFIER    

mea 1.3.6.1.4.1.1166.8
OBJECT IDENTIFIER    

addressablecontrol 1.3.6.1.4.1.1166.9
OBJECT IDENTIFIER    

acCommon 1.3.6.1.4.1.1166.9.1
OBJECT IDENTIFIER    

acSecurity 1.3.6.1.4.1.1166.9.2
OBJECT IDENTIFIER    

acServices 1.3.6.1.4.1.1166.9.3
OBJECT IDENTIFIER    

acBsi 1.3.6.1.4.1.1166.9.4
OBJECT IDENTIFIER    

acOperations 1.3.6.1.4.1.1166.9.5
OBJECT IDENTIFIER    

acTopology 1.3.6.1.4.1.1166.9.6
OBJECT IDENTIFIER    

chsInternal 1.3.6.1.4.1.1166.10
OBJECT IDENTIFIER    

emLogin 1.3.6.1.4.1.1166.10.1
OBJECT IDENTIFIER    

radiusClient 1.3.6.1.4.1.1166.10.2
OBJECT IDENTIFIER    

identSerialNumber 1.3.6.1.4.1.1166.7.1.1
This contains the serial number of the unit. There is no specification of the internal format of the serial number. The serial number is entered into either permanent or non- volatile memory of the unit at the time of manufacture. Note - the unit itself supplies the serial number.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

identChassisNumber 1.3.6.1.4.1.1166.7.1.2
This contains the chassis number of the unit. This is applicable only to a limited number of products, currently, only the ITEM-1000. For products for which this is not applicable, this will be a null object. There is no specification of the internal format of the chassis number. The means by which any product determines its chassis number is to be determined by each individual product.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

identIfIndex 1.3.6.1.4.1.1166.7.1.3
This contains the IfIndex of the OAM&P port.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

identHardwareVersion 1.3.6.1.4.1.1166.7.1.4
This contains a display string that defines the hardware version of this particular unit. There is no specification of the internal format of the hardware version. The hardware version is entered into the either permanent or non-volatile memory of the unit at the time of manufacture.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

identHardwareFeatures 1.3.6.1.4.1.1166.7.1.5
This contains a display string that defines the features of this particular unit. There is no specification of the internal format of the hardware features. The hardware features is entered into the either permanent or non-volatile memory of the unit at the time of manufacture.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

identInventoryCode 1.3.6.1.4.1.1166.7.1.6
This contains a display string that defines the inventory code for this unit. Once an inventory code has been set, it should be kept in non-volatile memory. The unit should only allow this object to be set when it is in the 'configuration' mode. There is no specification of the internal format of the inventory Code.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

identSoftwareVersion 1.3.6.1.4.1.1166.7.1.7
This contains a display string that defines the current version of the software for this unit. The format of the software version is a fully qualified directory name. This value is received by a unit as within a BOOTP response from the BOOTP server. It is available to the network manager for applications that track the installed software. Once the software version has been set, it should be kept in non-volatile memory.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

identLocationArea 1.3.6.1.4.1.1166.7.1.8
This is different from the MIB II sysLocation variable as it contains only the location area and does not describe the precise location. This contains a display string that defines the area in which the unit is installed. Location is defined by a set of three objects: 'Area', 'Rack', and 'Shelf'. These location objects cannot be determined by the unit itself, but can only be determined by the network manager. It is available to the unit for display on a front panel. Display of the location on the front panel is useful in validating the configuration established by the network manager. The unit should only allow this object to be set when it is in the 'configuration' mode. Once the Location Area has been set, it should be kept in non-volatile memory.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

identLocationRack 1.3.6.1.4.1.1166.7.1.9
This contains a display string that defines the rack in which the unit is installed. Location is defined by a set of three objects: 'Area', 'Rack', and 'Shelf'. These location objects cannot be determined by the unit itself, but can only be determined by the network manager. It is available to the unit for display on a front panel. Display of the location on the front panel is useful in validating the configuration established by the network manager. The unit should only allow this object to be set when it is in the 'configuration' mode. Once the Location Area has been set, it should be kept in non-volatile memory.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

identLocationShelf 1.3.6.1.4.1.1166.7.1.10
This contains a display string that defines the shelf in which the unit is installed. Location is defined by a set of three objects: 'Area', 'Rack', and 'Shelf'. These location objects cannot be determined by the unit itself, but can only be determined by the network manager. It is available to the unit for display on a front panel. Display of the location on the front panel is useful in validating the configuration established by the network manager. The unit should only allow this object to be set when it is in the 'configuration' mode. Once the Location Area has been set, it should be kept in non-volatile memory.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

identMIBVersion 1.3.6.1.4.1.1166.7.1.11
The version number of this MIB.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

identAgentVersion 1.3.6.1.4.1.1166.7.1.12
The version number of the Agent.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

identCommand 1.3.6.1.4.1.1166.7.1.13
This is the command to be executed by the resource managed by the agent. The value unspecified is always returned on SNMP Get/GetNext while the resource is running. If the restart(1) command is given, currentlyRestarting(2) is returned while the resource is preparing to restart (reboot).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER restart(1), currentlyRestarting(2), unspecified(3), purgeAndRestart(4), currentlyPurgingAndRestarting(5), purgeNvramAndRestart(6), currentlyPurgingNvramAndRestarting(7)  

identIfExtensionTable 1.3.6.1.4.1.1166.7.1.14
This table contains extensions to the MIB II ifTable which contains the definitions of all interfaces. An ifTable entry may be a board or just a port on a board. Any ifTable entry can have an extension in the identIfExtensionTable. The corrsponding entry in that table will have the identIfIndex = ifIndex. Within the ifTable the presence of such an entry is indicated by setting the variable ifSpecific to the OBJECT IDENTIFIER value of identIfExtensionTable. Otherwise iFSpecific is set to {0 0}. The ifType - other - is used for all board types not envisoned by MIB II.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IdentIfExtensionEntry

identIfExtensionEntry 1.3.6.1.4.1.1166.7.1.14.1
An entry (conceptual row) in the Board Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  IdentIfExtensionEntry  

identIfExtensionIndex 1.3.6.1.4.1.1166.7.1.14.1.1
Same value as ifIndex of MIB II for the same board.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

identIfSerialNumber 1.3.6.1.4.1.1166.7.1.14.1.2
This contains the serial number of the board. There is no specification of the internal format of the serial number. The serial number is entered into either permanent or non-volatile memory of the unit at the time of manufacture. Note - the unit itself supplies the serial number.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

identIfHardwareVersion 1.3.6.1.4.1.1166.7.1.14.1.3
This contains a display string that defines the version of this particular board. There is no specification of the internal format of the hardware version. The hardware version is entered into the either permanent or non-volatile memory of the unit at the time of manufacture.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

identIfHardwareFeatures 1.3.6.1.4.1.1166.7.1.14.1.4
This contains a display string that defines the features of this particular board. There is no specification of the internal format of the hardware features. The hardware features is entered into the either permanent or non-volatile memory of the unit at the time of manufacture.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

identIfInventoryCode 1.3.6.1.4.1.1166.7.1.14.1.5
This contains a display string that defines the inventory code for this board. This is an optional value; if there is no inventory code, The unit will respond with a null string. Once an inventory code has been set, it should be kept in non-volatile memory. The unit should only allow this object to be set when it is in the 'configuration' mode. There is no specification of the internal format of the inventory Code.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

identIfFirmwareVersion1 1.3.6.1.4.1.1166.7.1.14.1.6
Within a product, there may be several identifiers of such firmware, boot proms, kernel versions, flash versions, etc. This field (and the 3 that follow) are used to hold the identification of these items. These values must be entered into the board at the time of manufacturing. Unused fields are reported as null values. These fields are available to the network manager for applications that keep track of the firmware related identification. There is no specification of the internal format of firmware version identifiers.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

identIfFirmwareVersion2 1.3.6.1.4.1.1166.7.1.14.1.7
Firmware related identification field # 2.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

identIfFirmwareVersion3 1.3.6.1.4.1.1166.7.1.14.1.8
Firmware related identification field # 3.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

identIfFirmwareVersion4 1.3.6.1.4.1.1166.7.1.14.1.9
Firmware related identification field # 4
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

identIfSlotId 1.3.6.1.4.1.1166.7.1.14.1.10
This variable identifies the board slot.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..2147483647  

identIfCommand 1.3.6.1.4.1.1166.7.1.14.1.11
This is the command to be executed by the resource managed by the agent. The value unspecified(10 is always returned on SNMP Get/GetNext while the other values are set by the manager and executed by the resource.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unspecified(1), reset(2), restart(3), halt(4)  

identIfAdministrativeState 1.3.6.1.4.1.1166.7.1.14.1.12
The current Adminsitrative state of the interface as defined in ISO/IEC 10164-2.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER locked(1), unlocked(2), shuttingDown(3)  

identIfOperationalState 1.3.6.1.4.1.1166.7.1.14.1.13
The current Operational state of the interface as defined in ISO/IEC 10164-2
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

identIfAlarmStatus 1.3.6.1.4.1.1166.7.1.14.1.14
This object defines the Alarm status of the interface as defined in ISO/IEC 10164-2 and state-machine
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER underRepair(1), critical(2), major(3), minor(4), alarmOutstanding(5), idle(6)  

identIfAvailabilityStatus 1.3.6.1.4.1.1166.7.1.14.1.15
This object controls the Availability status of the interface as defined in ISO/IEC 10164-2 and state-machine
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER inTest(1), failed(2), powerOff(3), offLine(4), offDuty(5), dependency(6), degraded(7), notInstalled(8), logFull(9), available(10)  

identIfSpecific 1.3.6.1.4.1.1166.7.1.14.1.16
The object identifier of a board type specific extension to the ifTable if necessary. Otherwise, identIfSpecific is set to {0 0}.
Status: current Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

identIfEntryStatus 1.3.6.1.4.1.1166.7.1.14.1.17
This object is used to create, delete or modify a row in this table. To create a a new network element, this object is initially set to 'createRequest'. After completion of the configuration of the new entry, the manager must set the appropriate instance of this object to the value valid(1) or aborts, setting this object to invalid(4). This object must not be set to 'active' unless the following columnar objects exist in this row: identIfExtensionIndex identIfSerialNumber identIfHardwareVersion identIfInventoryCode identIfFirmwareVersion1 identIfSpecific To delete an existing entry in this table, the manager must set the appropriate instance of this object to the value invalid(4). Creation of an instance of this object has the effect of creating the supplemental object instances to complete the conceptual row. An existing instance of this entry cannot be created. If circumstances occur which cause an entry to become invalid, the agent modifies the value of the appropriate instance of this object to invalid(4). Whenever, the value of this object for a particular entry becomes invalid(4), the conceptual row for that instance may be removed from the table at any time, either immediately or subsequently.
Status: current Access: read-write
OBJECT-TYPE    
  EntryStatus  

identUnitModel 1.3.6.1.4.1.1166.7.1.15
This contains the model of the product. For example, the ITEM-1000 would contain 'ITEM1000'.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString