Baytech-MIB-403-1

File: Baytech-MIB-403-1.mib (82562 bytes)

Imported modules

RFC1155-SMI RFC1213-MIB RFC-1212
RFC-1215

Imported symbols

enterprises IpAddress Gauge
TimeTicks DisplayString OBJECT-TYPE
TRAP-TYPE

Defined Types

SDSNetworkConfigSNMPTrapReceiverEntry  
SEQUENCE    
  trapIndex INTEGER
  receiverAddress IpAddress

SDSModulesRPCEntry  
SEQUENCE    
  sBTAModulesRPCIndex INTEGER
  sBTAModulesRPCName DisplayString
  sBTAModulesRPCFirmwareVersion DisplayString
  sBTAModulesRPCCurrent INTEGER
  sBTAModulesRPCMaxCurrent INTEGER
  sBTAModulesRPCVoltage INTEGER
  sBTAModulesRPCPower INTEGER
  sBTAModulesRPCTemperature INTEGER
  sBTAModulesRPCRebootTimeout INTEGER
  sBTAModulesRPCAllOutletsCmd INTEGER
  sBTAModulesRPCAllOutletsStatus DisplayString
  sBTAModulesRPCCurrentAlarmThreshold INTEGER
  sBTAModulesRPCOverVoltageThreshold INTEGER
  sBTAModulesRPCUnderVoltageThreshold INTEGER
  sBTAModulesRPCNumberOfOutlets INTEGER
  sBTAModulesRPCCircuitBreaker INTEGER
  sBTAModulesRPCOverTempThreshold INTEGER
  sBTAModulesRPCUnitVA INTEGER
  sBTAModulesRPCNumberOfBreakers INTEGER
  sBTAModulesRPCLowCurrentThreshold INTEGER
  sBTAModulesRPCVoltageSource INTEGER
  sBTAModulesRPCSourceSwitchCount INTEGER
  sBTAModulesRPCNumberOfSensors INTEGER
  sBTAModulesRPCType DisplayString

SDSModulesRPCOutletEntry  
SEQUENCE    
  sBTAModulesRPCOutletModuleIndex INTEGER
  sBTAModulesRPCOutletIndex INTEGER
  sBTAModulesRPCOutletState INTEGER
  sBTAModulesRPCOutletName DisplayString

SDSModulesRPCCurrentGroupsCurrentEntry  
SEQUENCE    
  groupCurrentIndex INTEGER
  groupCurrent INTEGER
  rpcGroup DisplayString
  warningThreshold INTEGER
  emergencyThreshold INTEGER

SDSModulesRPCBreakersEntry  
SEQUENCE    
  sBTAModulesRPCBreakersModulesIndex INTEGER
  sBTAModulesRPCBreakersBreakersIndex INTEGER
  sBTAModulesRPCBreakersCircuitBreaker INTEGER
  sBTAModulesRPCBreakersCurrent INTEGER
  sBTAModulesRPCBreakersMaxCurrent INTEGER
  sBTAModulesRPCBreakersVoltage INTEGER
  sBTAModulesRPCBreakersPower INTEGER
  sBTAModulesRPCBreakersVA INTEGER
  sBTAModulesRPCBreakersCurrentAlarmThreshold INTEGER

SDSControlUserEntry  
SEQUENCE    
  sBTAControlUserIndex INTEGER
  sBTAControlUserName DisplayString
  sBTAControlUserAddress IpAddress
  sBTAControlUserConnection INTEGER
  sBTAControlUserConnModule INTEGER
  sBTAControlUserConnPort INTEGER
  sBTAControlUserTerminateUser INTEGER

SDSModulesRPCModPortEntry  
SEQUENCE    
  sRPCModuleIndex INTEGER
  sRPCPortIndex INTEGER
  sRPCType DisplayString
  sRPCName DisplayString
  sRPCFirmwareVersion DisplayString
  sRPCCurrent INTEGER
  sRPCMaxCurrent INTEGER
  sRPCVoltage INTEGER
  sRPCPower INTEGER
  sRPCTemperature INTEGER
  sRPCRebootTimeout INTEGER
  sRPCAllOutletsCmd INTEGER
  sRPCAllOutletsStatus DisplayString
  sRPCCurrentAlarmThreshold INTEGER
  sRPCOverVoltageThreshold INTEGER
  sRPCUnderVoltageThreshold INTEGER
  sRPCNumberOfOutlets INTEGER
  sRPCCircuitBreaker INTEGER
  sRPCOverTempThreshold INTEGER
  sRPCUnitVA INTEGER
  sRPCNumberOfBreakers INTEGER
  sRPCLowCurrentThreshold INTEGER
  sRPCVoltageSource INTEGER
  sRPCSourceSwitchCount INTEGER
  sRPCNumberOfSensors INTEGER

SDSModulesRPCModPortOutletEntry  
SEQUENCE    
  sRPCOutletModuleIndex INTEGER
  sRPCOutletPortIndex INTEGER
  sRPCOutletIndex INTEGER
  sRPCOutletState INTEGER
  sRPCOutletName DisplayString

SRPCModPortBreakersEntry  
SEQUENCE    
  sRPCBreakersModIndex INTEGER
  sRPCBreakersPortIndex INTEGER
  sRPCBreakersBreakersIndex INTEGER
  sRPCBreakersCircuitBreaker INTEGER
  sRPCBreakersCurrent INTEGER
  sRPCBreakersMaxCurrent INTEGER
  sRPCBreakersVoltage INTEGER
  sRPCBreakersPower INTEGER
  sRPCBreakersVA INTEGER
  sRPCBreakersCurrentAlarmThreshold INTEGER

SRPCOutletGroupEntry  
SEQUENCE    
  sRPCOutletGroupIndex INTEGER
  sRPCOutletGroupName DisplayString
  sRPCOutletGroupOutlets DisplayString
  sRPCOutletGroupCmd INTEGER

SDSModulesEnvironmentalObjectsEntry  
SEQUENCE    
  sBTAModulesEnvironmentalModulesIndex INTEGER
  sBTAModulesEnvironmentalSensorsIndex INTEGER
  sBTAModulesEnvironmentalType INTEGER
  sBTAModulesEnvironmentalName DisplayString
  sBTAModulesEnvironmentalMeasurement INTEGER
  sBTAModulesEnvironmentalHiThreshold INTEGER
  sBTAModulesEnvironmentalLoThreshold INTEGER
  sBTAModulesEnvironmentalMax INTEGER
  sBTAModulesEnvironmentalMin INTEGER
  sBTAModulesEnvironmentalHiThresholdEn INTEGER
  sBTAModulesEnvironmentalLoThresholdEn INTEGER
  sBTAModulesEnvironmentalStateTrapEn INTEGER

SRPCEnvironmentalObjectsEntry  
SEQUENCE    
  sRPCEnvironmentalModuleIndex INTEGER
  sRPCEnvironmentalPortIndex INTEGER
  sRPCEnvironmentalSensorsIndex INTEGER
  sRPCEnvironmentalType INTEGER
  sRPCEnvironmentalName DisplayString
  sRPCEnvironmentalMeasurement INTEGER
  sRPCEnvironmentalHiThreshold INTEGER
  sRPCEnvironmentalLoThreshold INTEGER
  sRPCEnvironmentalMax INTEGER
  sRPCEnvironmentalMin INTEGER
  sRPCEnvironmentalHiThresholdEn INTEGER
  sRPCEnvironmentalLoThresholdEn INTEGER
  sRPCEnvironmentalStateTrapEn INTEGER

Defined Values

baytech 1.3.6.1.4.1.4779
OBJECT IDENTIFIER    

btadevices 1.3.6.1.4.1.4779.1
OBJECT IDENTIFIER    

mtrapargs 1.3.6.1.4.1.4779.3
OBJECT IDENTIFIER    

sBTAIdent 1.3.6.1.4.1.4779.1.1
OBJECT IDENTIFIER    

sBTANetworkConfig 1.3.6.1.4.1.4779.1.2
OBJECT IDENTIFIER    

sBTAModules 1.3.6.1.4.1.4779.1.3
OBJECT IDENTIFIER    

sBTAControl 1.3.6.1.4.1.4779.1.4
OBJECT IDENTIFIER    

sBTAFileTransfer 1.3.6.1.4.1.4779.1.5
OBJECT IDENTIFIER    

sBTAEnvironmental 1.3.6.1.4.1.4779.1.6
OBJECT IDENTIFIER    

sBTAIdentFirmwareRev 1.3.6.1.4.1.4779.1.1.1
An 8 byte ID string identifying the DS72 firmware revision. This value is set at the factory.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sBTAIdentSerialNumber 1.3.6.1.4.1.4779.1.1.2
A number identifying the serial number of the DS72. This value is set at the factory.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sBTAIdentUnitName 1.3.6.1.4.1.4779.1.1.3
A 64-character string identifying the name (UnitID) of the DS72. This value is set at the factory to a default of DS72.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(64)  

sBTANetworkConfigBootpEnable 1.3.6.1.4.1.4779.1.2.1
Enables/disables bootp. Bootp will not take effect until the unit is reseted.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

sBTANetworkConfigDHCPEnable 1.3.6.1.4.1.4779.1.2.2
Enables/disables DHCP. DHCP will not take effect until the unit is reseted.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

sBTANetworkConfigSSHEnable 1.3.6.1.4.1.4779.1.2.3
Enables/disables SSH logins. Disable/enable SSH will take effect after the unit is reseted.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

sBTANetworkConfigTelnetEnable 1.3.6.1.4.1.4779.1.2.4
Enables/disables telnet.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

sBTANetworkConfigActivityTimeout 1.3.6.1.4.1.4779.1.2.5
A value from 0 to 120. 0 disables activity timeouts. Value represents minutes of non-activity before telnet / SSH sessions are automatically logged out. Default is 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sBTANetworkConfigDirectConnEnable 1.3.6.1.4.1.4779.1.2.6
Enables/disables direct port connection upon login.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

sBTANetworkConfigSNMP 1.3.6.1.4.1.4779.1.2.8
OBJECT IDENTIFIER    

sBTANetworkConfigRadius 1.3.6.1.4.1.4779.1.2.9
OBJECT IDENTIFIER    

sBTANetworkConfigWEB 1.3.6.1.4.1.4779.1.2.10
OBJECT IDENTIFIER    

sBTANetworkConfigSNMPReadOnlyCommunity 1.3.6.1.4.1.4779.1.2.8.1
The community name to use for read only access. Maximum len 16 bytes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

sBTANetworkConfigSNMPReadWriteCommunity 1.3.6.1.4.1.4779.1.2.8.2
The community name to use for read-write access. Maximum len 16 bytes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

sBTANetworkConfigSNMPNumTrapReceivers 1.3.6.1.4.1.4779.1.2.8.3
The maximum number of managers to send traps to. Currently 4.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sBTANetworkConfigSNMPTrapReceiverTable 1.3.6.1.4.1.4779.1.2.8.4
A list of managers to send traps to. The number of entries is given by the value of sBTANetworkConfigSNMPNumTrapReceivers. Maximum number of Trap Receivers is four.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SDSNetworkConfigSNMPTrapReceiverEntry

sBTANetworkConfigSNMPTrapReceiverEntry 1.3.6.1.4.1.4779.1.2.8.4.1
Table of managers to send traps to.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SDSNetworkConfigSNMPTrapReceiverEntry  

trapIndex 1.3.6.1.4.1.4779.1.2.8.4.1.1
The index to a trap receiver entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

receiverAddress 1.3.6.1.4.1.4779.1.2.8.4.1.2
The IP address of the manager to send traps to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

sBTANetworkConfigRadiusEnable 1.3.6.1.4.1.4779.1.2.9.1
Enables / disables RADIUS telnet logins.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

sBTANetworkConfigRadiusPrimaryServer 1.3.6.1.4.1.4779.1.2.9.2
Ip address of the primary RADIUS server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

sBTANetworkConfigRadiusSecondaryServer 1.3.6.1.4.1.4779.1.2.9.3
Ip address of the back-up RADIUS server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

sBTANetworkConfigRadiusLocalLogin 1.3.6.1.4.1.4779.1.2.9.4
Enables / disables the use of local (usernames stored in the DS72) logins in the case that both the primary and secondary RADIUS server are not available.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

sBTANetworkConfigWebEnable 1.3.6.1.4.1.4779.1.2.10.1
Enables WEB.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

sBTANetworkConfigWebSecureEnable 1.3.6.1.4.1.4779.1.2.10.2
Enables WEB Security.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

sBTANetworkConfigWebLoginEnable 1.3.6.1.4.1.4779.1.2.10.3
Enables WEB Login.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

sBTANetworkConfigWebActivityTimeout 1.3.6.1.4.1.4779.1.2.10.4
A value from 0 to 120. 0 disables WEB activity timeouts. Value represents minutes of non-activity before WEB sessions are automatically logged out. Default is 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sBTAModulesNumberOfModules 1.3.6.1.4.1.4779.1.3.1
Number of modules installed into the DS unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sBTAModulesModulesInstalled 1.3.6.1.4.1.4779.1.3.2
A character string listing the modules installed seperated by commas. Each module is identifed by a two digit number indicating the slot. For example 02,03,04,06 means modules 2,3,4 and 6 are installed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sBTAModulesResetModulesCmd 1.3.6.1.4.1.4779.1.3.3
This command is no longer supported.
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER  

sBTAModulesNumberOfIntelligentModules 1.3.6.1.4.1.4779.1.3.4
The number of Intelligent Modules installed in the DS Unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPC 1.3.6.1.4.1.4779.1.3.5
OBJECT IDENTIFIER    

sBTAModulesSerial 1.3.6.1.4.1.4779.1.3.6
OBJECT IDENTIFIER    

sBTAModulesModem 1.3.6.1.4.1.4779.1.3.7
OBJECT IDENTIFIER    

sBTAModulesNumberOfRPCModules 1.3.6.1.4.1.4779.1.3.5.1
The number of DS30 Modules installed in the DS Unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCTable 1.3.6.1.4.1.4779.1.3.5.2
Allows for control of individual outlets and individual RPC modules.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SDSModulesRPCEntry

sBTAModulesRPCEntry 1.3.6.1.4.1.4779.1.3.5.2.1
The RPCs to control and get status on.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SDSModulesRPCEntry  

sBTAModulesRPCIndex 1.3.6.1.4.1.4779.1.3.5.2.1.1
The index into the RPC table. Indexes for rpcs attached to ds74 modules are calculate with the following formula: ((module - 2) * 4) + port. For example module 3 port 1 = index 5.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCName 1.3.6.1.4.1.4779.1.3.5.2.1.2
The name (unit id) of the rpc.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

sBTAModulesRPCFirmwareVersion 1.3.6.1.4.1.4779.1.3.5.2.1.3
The firware version of the rpc.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sBTAModulesRPCCurrent 1.3.6.1.4.1.4779.1.3.5.2.1.4
The current reading for the power strip. If current measurement is not installed this value will always read 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCMaxCurrent 1.3.6.1.4.1.4779.1.3.5.2.1.5
The maximum detected current reading for the power strip. If current measurement is not installed this value will always read 0. Setting this value to 0 will clear the maximum current detected.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCVoltage 1.3.6.1.4.1.4779.1.3.5.2.1.6
The voltage reading for the power strip. If voltage measurement is not installed this value will always read 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCPower 1.3.6.1.4.1.4779.1.3.5.2.1.7
The power reading for the power strip. If power measurement is not installed this value will always read 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCTemperature 1.3.6.1.4.1.4779.1.3.5.2.1.8
The temperature reading for the power strip. Readings are in degrees C. If temperature measurement is not installed this value will always read 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCRebootTimeout 1.3.6.1.4.1.4779.1.3.5.2.1.9
The length of off time for automatic reboot sequences. Currently a read-only value set to the fixed reboot timeout.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCAllOutletsCmd 1.3.6.1.4.1.4779.1.3.5.2.1.10
Turns all outlets on, off or reboot. 0 = off 1 = on 2 = reboot A get will return unknown (6).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(0), on(1), reboot(2), lockon(3), lockoff(4), unlock(5), unknown(6)  

sBTAModulesRPCAllOutletsStatus 1.3.6.1.4.1.4779.1.3.5.2.1.11
Reports status of outlets in a comma deliminated string. 0 = off 1 = on 2 = reboot 3 = locked on 4 = locked off
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sBTAModulesRPCCurrentAlarmThreshold 1.3.6.1.4.1.4779.1.3.5.2.1.12
The current alarm threshold level *10. A value of 105 will set the level to 10.5.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCOverVoltageThreshold 1.3.6.1.4.1.4779.1.3.5.2.1.13
The over voltage alarm threshold level *10. A value of 105 will set the level to 10.5.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCUnderVoltageThreshold 1.3.6.1.4.1.4779.1.3.5.2.1.14
The under voltage alarm threshold level *10. A value of 105 will set the level to 10.5.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCNumberOfOutlets 1.3.6.1.4.1.4779.1.3.5.2.1.15
Number of outlets for this RPC. This will be the size of outlet table for this RPC index.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCCircuitBreaker 1.3.6.1.4.1.4779.1.3.5.2.1.16
Status of circuit breaker in power strip. 0=off 1=on.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(0), on(1)  

sBTAModulesRPCOverTempThreshold 1.3.6.1.4.1.4779.1.3.5.2.1.17
The over temperature alarm threshold level *10. A value of 505 will set the level to 50.5.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCUnitVA 1.3.6.1.4.1.4779.1.3.5.2.1.18
Total Volt-Amps for this RPC.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCNumberOfBreakers 1.3.6.1.4.1.4779.1.3.5.2.1.19
Number of breakers for this RPC.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCLowCurrentThreshold 1.3.6.1.4.1.4779.1.3.5.2.1.20
Low current threshold for this RPC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCVoltageSource 1.3.6.1.4.1.4779.1.3.5.2.1.21
Voltage source for this RPC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCSourceSwitchCount 1.3.6.1.4.1.4779.1.3.5.2.1.22
Count of Voltage Source Switches for this RPC.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCNumberOfSensors 1.3.6.1.4.1.4779.1.3.5.2.1.23
Number of environmental sensors for this RPC.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCType 1.3.6.1.4.1.4779.1.3.5.2.1.24
The type of RPC installed at the indexed location.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sBTAModulesRPCOutletTable 1.3.6.1.4.1.4779.1.3.5.3
Allows for control of individual outlets. The number of entries is contained in the sBTAModulesRPCOutletTableSize OID.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SDSModulesRPCOutletEntry

sBTAModulesRPCOutletEntry 1.3.6.1.4.1.4779.1.3.5.3.1
The outlets to control and get status on.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SDSModulesRPCOutletEntry  

sBTAModulesRPCOutletModuleIndex 1.3.6.1.4.1.4779.1.3.5.3.1.1
The index to the outlet entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCOutletIndex 1.3.6.1.4.1.4779.1.3.5.3.1.2
The index to the outlet entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCOutletState 1.3.6.1.4.1.4779.1.3.5.3.1.3
Getting this variable will return the state of the outlet. Valid return states are unknown, on, off, lockon, lockoff. 0 = off 1 = on 2 = reboot 3 = lockon (outlet is on and no changes are allowed) 4 = lockoff (outlet is off and no changes are allowed) 5 = unlock.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(0), on(1), reboot(2), lockon(3), lockoff(4), unlock(5), unknown(6)  

sBTAModulesRPCOutletName 1.3.6.1.4.1.4779.1.3.5.3.1.4
The name of the outlet. Maximum size is 16 characters.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

sBTAModulesRPCGroupCmd 1.3.6.1.4.1.4779.1.3.5.4
A character string listing the outlets that need to be controlled, turned off, or turn on as a group. Command is the first character followed by a space. Valid commads are 0=off,1=on, or 2=reboot. A list follows the command in the format module.outlet. For example 2 2.1,2.12,3.1 will reboot module 2 outlet 2&12 module 3 outlet 1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

sBTAModulesRPCCurrentGroupsCurrentTable 1.3.6.1.4.1.4779.1.3.5.8
A list of total current for RPCs in each current group
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SDSModulesRPCCurrentGroupsCurrentEntry

sBTAModulesRPCCurrentGroupsCurrentEntry 1.3.6.1.4.1.4779.1.3.5.8.1
Table of total current measurement by group
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SDSModulesRPCCurrentGroupsCurrentEntry  

groupCurrentIndex 1.3.6.1.4.1.4779.1.3.5.8.1.1
The index to a group total current.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

groupCurrent 1.3.6.1.4.1.4779.1.3.5.8.1.2
Current total for all RPCs in group.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rpcGroup 1.3.6.1.4.1.4779.1.3.5.8.1.3
A character string listing the RPCs, by port index, that will be included in a measurement of total current. For each group, a sum will be periodically computed of currents of all listed RPCs, which will be compared to warning and emergency thresholds, generating appropriate traps as required by transit of a threshold. A maximum of 8 RPCs may be monitored within a group. The RPC must be connected and operating and the corresponding DS74 serial port must be configured for an RPC-SNMP device type to be allowed group membership.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

warningThreshold 1.3.6.1.4.1.4779.1.3.5.8.1.4
The current level, in tenths of an amp, that will cause a Current Level Warning trap to be sent if the total current for the associated group if exceeded. Conversely, a Current Level Warning Clear trap will be sent whent the total group current falls below the threshold.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

emergencyThreshold 1.3.6.1.4.1.4779.1.3.5.8.1.5
The current level, in tenths of an amp, that will cause a Current Level Emergency trap to be sent if the total current for the associated group if exceeded. Conversely, a Current Level Emergeny Clear trap will be sent whent the total group current falls below the threshold.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCBreakersTable 1.3.6.1.4.1.4779.1.3.5.9
Allows monitoring of individual outlet strips on RPCs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SDSModulesRPCBreakersEntry

sBTAModulesRPCBreakersEntry 1.3.6.1.4.1.4779.1.3.5.9.1
Status organization by breaker.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SDSModulesRPCBreakersEntry  

sBTAModulesRPCBreakersModulesIndex 1.3.6.1.4.1.4779.1.3.5.9.1.1
The index into the RPC table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCBreakersBreakersIndex 1.3.6.1.4.1.4779.1.3.5.9.1.2
The index into the RPC breaker table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCBreakersCircuitBreaker 1.3.6.1.4.1.4779.1.3.5.9.1.3
Status of circuit breaker in power strip. 0=off 1=on.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(0), on(1)  

sBTAModulesRPCBreakersCurrent 1.3.6.1.4.1.4779.1.3.5.9.1.4
The detected current reading for the power strip. If current measurement is not installed this value will always read 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCBreakersMaxCurrent 1.3.6.1.4.1.4779.1.3.5.9.1.5
The maximum detected current reading for the power strip. If current measurement is not installed this value will always read 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCBreakersVoltage 1.3.6.1.4.1.4779.1.3.5.9.1.6
The voltage reading for the power strip. If voltage measurement is not installed this value will always read 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCBreakersPower 1.3.6.1.4.1.4779.1.3.5.9.1.7
The power reading for the power strip. If voltage measurement is not installed this value will always read 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCBreakersVA 1.3.6.1.4.1.4779.1.3.5.9.1.8
The volt-amps reading for the power strip. If voltage measurement is not installed this value will always read 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCBreakersCurrentAlarmThreshold 1.3.6.1.4.1.4779.1.3.5.9.1.9
The current alarm threshold level *10. A value of 105 will set the level to 10.5.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sBTAControlResetUnit 1.3.6.1.4.1.4779.1.4.1
Setting this value to 1 will cause the unit to reset. A get of this OID will return 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noreset(0), reset(1)  

sBTAControlResetModules 1.3.6.1.4.1.4779.1.4.2
Setting this value to 1 will cause the unit to reset modules simular to the telnet RM command. A get of this OID will return 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noreset(0), reset(1)  

sBTAControlNumOfLoggedUsers 1.3.6.1.4.1.4779.1.4.3
Number of users logged in via telnet or SSH.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sBTAControlUserTable 1.3.6.1.4.1.4779.1.4.4
A list of users and user information. The number of entries is contained in the sBTAControlNumOfLoggedUsers OID.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SDSControlUserEntry

sBTAControlUserEntry 1.3.6.1.4.1.4779.1.4.4.1
The users to get status on.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SDSControlUserEntry  

sBTAControlUserIndex 1.3.6.1.4.1.4779.1.4.4.1.1
The index to the user entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sBTAControlUserName 1.3.6.1.4.1.4779.1.4.4.1.2
The username of the user.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sBTAControlUserAddress 1.3.6.1.4.1.4779.1.4.4.1.3
The IP address of the user.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

sBTAControlUserConnection 1.3.6.1.4.1.4779.1.4.4.1.4
Type of connection. If unknown, user is logging out or the connection is invalid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER serialport(0), telnet(1), ssh(2), unknown(4)  

sBTAControlUserConnModule 1.3.6.1.4.1.4779.1.4.4.1.5
If the user is connected to a module, this value will report the module number connected to. If the value is 0 the user is not connected to a module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sBTAControlUserConnPort 1.3.6.1.4.1.4779.1.4.4.1.6
The port number with in a module that the user is connected to. This usually only applies to connections to DS74 serial modules. Intelligent modules connections are always made on port 1. If value is 0 the user is not connected to a module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sBTAControlUserTerminateUser 1.3.6.1.4.1.4779.1.4.4.1.7
Settings this OID to anything but 0 will terminate (log out) the user. A get of this OID will return 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER terminate(1)  

sBTAFileTransferEnableUpgradeFTPFileTransfer 1.3.6.1.4.1.4779.1.5.1
Setting this OID to enableUpgradeFileTransferDownloadViaFTP (1) will start the FTP server and place the DS72 in upgrade mode. An FTP connection may then be established for the purpose of transmitting a firmware upgrade file.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enableUpgradeFileTransferDownloadViaFTP(1)  

mtrapargsInteger 1.3.6.1.4.1.4779.3.1
This OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. A get of this OID will return 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mtrapargsIpAddress 1.3.6.1.4.1.4779.3.2
This OID allows bayteh traps to be sent with an IP address argument that may not be defined in the baytech MIB. A get of this OID will return 0.0.0.0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

mtrapargsString 1.3.6.1.4.1.4779.3.3
This OID allows baytech traps to be sent with an octet string argument that may not be defined in the baytech MIB. A get of this OID will return a NULL string.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

mtrapargsGauge 1.3.6.1.4.1.4779.3.4
This OID allows baytech traps to be sent with a Gauge argument that may not be defined in the baytech MIB. A get of this OID will return 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

mtrapargsTimeTicks 1.3.6.1.4.1.4779.3.5
This OID allows baytech traps to be sent with a TimeTicks argument that may not be defined in the baytech MIB. A get of this OID will return 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

sBTAModuleIndex 1.3.6.1.4.1.4779.3.6
This OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. This is an index to a specific DS module. Value will equal the slot of the module. A get of this OID will return 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sBTAOutletIndex 1.3.6.1.4.1.4779.3.7
This OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. This is an index to a specific outlet in a DS module. Value is 1 to number of outlets controlled by the ds module. 0 represents all outlets. A get of this OID will return 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sBTAPortIndex 1.3.6.1.4.1.4779.3.8
This OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. This is an index to a specific outlet in a DS module. Value is 1 to number of outlets controlled by the ds module. 0 represents all outlets. A get of this OID will return 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sBTAVoltageSource 1.3.6.1.4.1.4779.3.9
This OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. This is the number associated with the voltage source in an RPC. Value is 1 or 2, depending on which voltage source is powering the RPC. A get of this OID will return 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sBTASourceSwitchCount 1.3.6.1.4.1.4779.3.10
This OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. This is the number associated with the number of voltage source transitions in an RPC. Value is 0 to 255, an 8-bit w/rollover count of number of times voltage source has been switched from one source to another. A get of this OID will return 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sBTASensorIndex 1.3.6.1.4.1.4779.3.11
This OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. This is an index to a specific sensor in a DS module. Value is 1 to number of sensors controlled by the ds module. A get of this OID will return 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sBTABreakerIndex 1.3.6.1.4.1.4779.3.12
This is an object which is sent along with a trap to designate a breaker number pertinent to a particular trap. This value will range from 1 to the total number of breakers inside the particular RPC. A get of this OID will return 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCModPortTable 1.3.6.1.4.1.4779.1.3.5.5
Allows for control of individual outlets and individual RPC modules. The number of entries is contained in the sBTAModulesNumberOfRPCModules OID.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SDSModulesRPCModPortEntry

sBTAModulesRPCModPortEntry 1.3.6.1.4.1.4779.1.3.5.5.1
The RPCs to control and get status on.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SDSModulesRPCModPortEntry  

sRPCModuleIndex 1.3.6.1.4.1.4779.1.3.5.5.1.1
The module number index into the RPC table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sRPCPortIndex 1.3.6.1.4.1.4779.1.3.5.5.1.2
The port number index into the RPC table. In the case of ds30 modules this number is always 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sRPCType 1.3.6.1.4.1.4779.1.3.5.5.1.3
Type of RPC at the module, port index.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sRPCName 1.3.6.1.4.1.4779.1.3.5.5.1.4
The name (unit id) of the rpc module.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

sRPCFirmwareVersion 1.3.6.1.4.1.4779.1.3.5.5.1.5
The firware version of the rpc module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sRPCCurrent 1.3.6.1.4.1.4779.1.3.5.5.1.6
The current reading for the power strip. If current measurement is not installed this value will always read 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sRPCMaxCurrent 1.3.6.1.4.1.4779.1.3.5.5.1.7
The maximum detected current reading for the power strip. If current measurement is not installed this value will always read 0. Setting this value to 0 will clear the maximum current detected.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sRPCVoltage 1.3.6.1.4.1.4779.1.3.5.5.1.8
The voltage reading for the power strip. If voltage measurement is not installed this value will always read 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sRPCPower 1.3.6.1.4.1.4779.1.3.5.5.1.9
The power reading for the power strip. If power measurement is not installed this value will always read 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sRPCTemperature 1.3.6.1.4.1.4779.1.3.5.5.1.10
The temperature reading for the power strip. Readings are in degrees C. If temperature measurement is not installed this value will always read 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sRPCRebootTimeout 1.3.6.1.4.1.4779.1.3.5.5.1.11
The length of off time for automatic reboot sequences. Currently a read-only value set to the fixed reboot timeout.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sRPCAllOutletsCmd 1.3.6.1.4.1.4779.1.3.5.5.1.12
Turns all outlets on, off or reboot. 0 = off 1 = on 2 = reboot 3 = lockon (will lock outlets to on state) 4 = lockoff (will lock outlets to off state) 5 = unlock (will unlock all outlets) A get will return unknown (6).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(0), on(1), reboot(2), lockon(3), lockoff(4), unlock(5), unknown(6)  

sRPCAllOutletsStatus 1.3.6.1.4.1.4779.1.3.5.5.1.13
Reports status of outlets in a comma deliminated string. 0 = off 1 = on 2 = reboot 3 = locked on 4 = locked off
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sRPCCurrentAlarmThreshold 1.3.6.1.4.1.4779.1.3.5.5.1.14
The current alarm threshold level *10. A value of 105 will set the level to 10.5.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sRPCOverVoltageThreshold 1.3.6.1.4.1.4779.1.3.5.5.1.15
The over voltage alarm threshold level *10. A value of 105 will set the level to 10.5.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sRPCUnderVoltageThreshold 1.3.6.1.4.1.4779.1.3.5.5.1.16
The under voltage alarm threshold level *10. A value of 105 will set the level to 10.5.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sRPCNumberOfOutlets 1.3.6.1.4.1.4779.1.3.5.5.1.17
Number of outlets for this RPC. This will be the size of outlet table for this RPC index.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sRPCCircuitBreaker 1.3.6.1.4.1.4779.1.3.5.5.1.18
Status of circuit breaker in power strip. 0=off 1=on.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(0), on(1)  

sRPCOverTempThreshold 1.3.6.1.4.1.4779.1.3.5.5.1.19
The over temperature alarm threshold level *10. A value of 505 will set the level to 50.5.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sRPCUnitVA 1.3.6.1.4.1.4779.1.3.5.5.1.20
Number of outlets for this RPC. This will be the size of outlet table for this RPC index.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sRPCNumberOfBreakers 1.3.6.1.4.1.4779.1.3.5.5.1.21
Number of breakers for this RPC.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sRPCLowCurrentThreshold 1.3.6.1.4.1.4779.1.3.5.5.1.22
Low current threshold for this RPC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sRPCVoltageSource 1.3.6.1.4.1.4779.1.3.5.5.1.23
Voltage source for this RPC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sRPCSourceSwitchCount 1.3.6.1.4.1.4779.1.3.5.5.1.24
Voltage source switch count for this RPC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sRPCNumberOfSensors 1.3.6.1.4.1.4779.1.3.5.5.1.25
Number of sensors for this RPC.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCModPortOutletTable 1.3.6.1.4.1.4779.1.3.5.6
Allows for control of individual outlets. The number of entries is contained in the sBTAModulesRPCOutletTableSize OID.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SDSModulesRPCModPortOutletEntry

sBTAModulesRPCModPortOutletEntry 1.3.6.1.4.1.4779.1.3.5.6.1
The outlets to control and get status on.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SDSModulesRPCModPortOutletEntry  

sRPCOutletModuleIndex 1.3.6.1.4.1.4779.1.3.5.6.1.1
The module index to the outlet entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sRPCOutletPortIndex 1.3.6.1.4.1.4779.1.3.5.6.1.2
The port index to the outlet entry. In the case of ds30s this number is always 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sRPCOutletIndex 1.3.6.1.4.1.4779.1.3.5.6.1.3
The outlet index to the outlet entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sRPCOutletState 1.3.6.1.4.1.4779.1.3.5.6.1.4
Getting this variable will return the state of the outlet. Valid return states are unknown, on, off, lockon, lockoff. 0 = off 1 = on 2 = reboot 3 = lockon (outlet is on and no changes are allowed) 4 = lockoff (outlet is off and no changes are allowed) 5 = unlock.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(0), on(1), reboot(2), lockon(3), lockoff(4), unlock(5), unknown(6)  

sRPCOutletName 1.3.6.1.4.1.4779.1.3.5.6.1.5
The name of the outlet. Maximum size is 16 characters.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

sBTAModulesRPCModPortGroupCmd 1.3.6.1.4.1.4779.1.3.5.7
A character string listing the outlets that need to be rebooted, turned off, or turn on as a group. Command is the first character followed by a space. Valid commads are 0=off,1=on, or 2=reboot. A list follows the command in the format module.port.outlet. For example 2 2.1.1,2.1.12,3.4.1 will reboot module 2 port 1 outlet 2&12 module 3 port 4 outlet 1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

sRPCModPortBreakersTable 1.3.6.1.4.1.4779.1.3.5.10
Allows monitoring of individual outlet strips on RPCs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SRPCModPortBreakersEntry

sRPCModPortBreakersEntry 1.3.6.1.4.1.4779.1.3.5.10.1
Status organization by breaker.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SRPCModPortBreakersEntry  

sRPCBreakersModIndex 1.3.6.1.4.1.4779.1.3.5.10.1.1
The module index into the RPC breaker table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sRPCBreakersPortIndex 1.3.6.1.4.1.4779.1.3.5.10.1.2
The port index into the RPC breaker table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sRPCBreakersBreakersIndex 1.3.6.1.4.1.4779.1.3.5.10.1.3
The breaker index into the RPC breaker table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sRPCBreakersCircuitBreaker 1.3.6.1.4.1.4779.1.3.5.10.1.4
Status of circuit breaker in power strip. 0=off 1=on.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(0), on(1)  

sRPCBreakersCurrent 1.3.6.1.4.1.4779.1.3.5.10.1.5
The detected current reading for the power strip. If current measurement is not installed this value will always read 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sRPCBreakersMaxCurrent 1.3.6.1.4.1.4779.1.3.5.10.1.6
The maximum detected current reading for the power strip. If current measurement is not installed this value will always read 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sRPCBreakersVoltage 1.3.6.1.4.1.4779.1.3.5.10.1.7
The voltage reading for the power strip. If voltage measurement is not installed this value will always read 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sRPCBreakersPower 1.3.6.1.4.1.4779.1.3.5.10.1.8
The power reading for the power strip. If voltage measurement is not installed this value will always read 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sRPCBreakersVA 1.3.6.1.4.1.4779.1.3.5.10.1.9
The volt-amps reading for the power strip. If voltage measurement is not installed this value will always read 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sRPCBreakersCurrentAlarmThreshold 1.3.6.1.4.1.4779.1.3.5.10.1.10
The current alarm threshold level x10. A value of 105 will set the level to 10.5.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sRPCOutletGroupTable 1.3.6.1.4.1.4779.1.3.5.11
Allows control of outlets via a group of up to four outlets.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SRPCOutletGroupEntry

sRPCOutletGroupEntry 1.3.6.1.4.1.4779.1.3.5.11.1
Organized by group number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SRPCOutletGroupEntry  

sRPCOutletGroupIndex 1.3.6.1.4.1.4779.1.3.5.11.1.1
The index into the outlet group table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sRPCOutletGroupName 1.3.6.1.4.1.4779.1.3.5.11.1.2
The name of the outlet group.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

sRPCOutletGroupOutlets 1.3.6.1.4.1.4779.1.3.5.11.1.3
The list of outlets in the outlet group. Format is mod.port.outlet,mod.port.outlet up to 4 outlets.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

sRPCOutletGroupCmd 1.3.6.1.4.1.4779.1.3.5.11.1.4
Command for outlet group. Same rules as rpc commands.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(0), on(1), reboot(2), lockon(3), lockoff(4), unlock(5), unknown(6)  

sBTAModulesEnvironmentalObjectsTable 1.3.6.1.4.1.4779.1.6.1
Allows monitoring of individual outlet strips on RPCs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SDSModulesEnvironmentalObjectsEntry

sBTAModulesEnvironmentalObjectsEntry 1.3.6.1.4.1.4779.1.6.1.1
Status organization by sensor.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SDSModulesEnvironmentalObjectsEntry  

sBTAModulesEnvironmentalModulesIndex 1.3.6.1.4.1.4779.1.6.1.1.1
Module Index for Environemntal table
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sBTAModulesEnvironmentalSensorsIndex 1.3.6.1.4.1.4779.1.6.1.1.2
Sensor Index for Environemntal table
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sBTAModulesEnvironmentalType 1.3.6.1.4.1.4779.1.6.1.1.3
Environmental Object Type.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sBTAModulesEnvironmentalName 1.3.6.1.4.1.4779.1.6.1.1.4
The name for the environmental object.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

sBTAModulesEnvironmentalMeasurement 1.3.6.1.4.1.4779.1.6.1.1.5
The measurement or state for the object.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sBTAModulesEnvironmentalHiThreshold 1.3.6.1.4.1.4779.1.6.1.1.6
Hi threshold for object.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sBTAModulesEnvironmentalLoThreshold 1.3.6.1.4.1.4779.1.6.1.1.7
Lo threshold for object.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sBTAModulesEnvironmentalMax 1.3.6.1.4.1.4779.1.6.1.1.8
Max value recorded for object since last reset.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sBTAModulesEnvironmentalMin 1.3.6.1.4.1.4779.1.6.1.1.9
Min value recorded for object since last reset.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sBTAModulesEnvironmentalHiThresholdEn 1.3.6.1.4.1.4779.1.6.1.1.10
Hi threshold enable for object.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sBTAModulesEnvironmentalLoThresholdEn 1.3.6.1.4.1.4779.1.6.1.1.11
Lo threshold enable for object.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sBTAModulesEnvironmentalStateTrapEn 1.3.6.1.4.1.4779.1.6.1.1.12
Trap enable for environmental sensors with contacts.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sRPCEnvironmentalObjectsTable 1.3.6.1.4.1.4779.1.6.2
Allows monitoring of individual outlet strips on RPCs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SRPCEnvironmentalObjectsEntry

sRPCEnvironmentalObjectsEntry 1.3.6.1.4.1.4779.1.6.2.1
Status organization by sensor.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SRPCEnvironmentalObjectsEntry  

sRPCEnvironmentalModuleIndex 1.3.6.1.4.1.4779.1.6.2.1.1
Module Index for Environemntal table
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sRPCEnvironmentalPortIndex 1.3.6.1.4.1.4779.1.6.2.1.2
Port Index for Environemntal table
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sRPCEnvironmentalSensorsIndex 1.3.6.1.4.1.4779.1.6.2.1.3
Sensor Index for Environemntal table
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sRPCEnvironmentalType 1.3.6.1.4.1.4779.1.6.2.1.4
Environmental Object Type.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sRPCEnvironmentalName 1.3.6.1.4.1.4779.1.6.2.1.5
The name for the environmental object.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

sRPCEnvironmentalMeasurement 1.3.6.1.4.1.4779.1.6.2.1.6
The measurement or state for the object.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sRPCEnvironmentalHiThreshold 1.3.6.1.4.1.4779.1.6.2.1.7
Hi threshold for object.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sRPCEnvironmentalLoThreshold 1.3.6.1.4.1.4779.1.6.2.1.8
Lo threshold for object.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sRPCEnvironmentalMax 1.3.6.1.4.1.4779.1.6.2.1.9
Max value recorded for object since last reset.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sRPCEnvironmentalMin 1.3.6.1.4.1.4779.1.6.2.1.10
Min value recorded for object since last reset.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sRPCEnvironmentalHiThresholdEn 1.3.6.1.4.1.4779.1.6.2.1.11
Hi threshold enable for object.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sRPCEnvironmentalLoThresholdEn 1.3.6.1.4.1.4779.1.6.2.1.12
Lo threshold enable for object.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sRPCEnvironmentalStateTrapEn 1.3.6.1.4.1.4779.1.6.2.1.13
Trap enable for environmental sensors with contacts.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sBTAEnvironmentalAllTemperatureSensorsHiThreshold 1.3.6.1.4.1.4779.1.6.3
Hi Threshold for all temperature sensors.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sBTAEnvironmentalAllTemperatureSensorsLoThreshold 1.3.6.1.4.1.4779.1.6.4
Lo Threshold for all temperature sensors.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sBTAEnvironmentalAllTemperatureSensorsHiThresholdTrapEnable 1.3.6.1.4.1.4779.1.6.5
Hi Threshold trap enable for all temperature sensors.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sBTAEnvironmentalAllTemperatureSensorsLoThresholdTrapEnable 1.3.6.1.4.1.4779.1.6.6
Lo Threshold trap enable for all temperature sensors.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sBTAEnvironmentalAllSensorsStateTrapEnable 1.3.6.1.4.1.4779.1.6.7
State change environmental sensor (ex: contact) trap enable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sBTAEnvironmentalAllHumiditySensorsHiThreshold 1.3.6.1.4.1.4779.1.6.8
Hi Threshold for all humidity sensors.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sBTAEnvironmentalAllHumiditySensorsLoThreshold 1.3.6.1.4.1.4779.1.6.9
Lo Threshold for all humidity sensors.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sBTAEnvironmentalAllHumiditySensorsHiThresholdTrapEnable 1.3.6.1.4.1.4779.1.6.10
Hi Threshold trap enable for all humidity sensors.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sBTAEnvironmentalAllHumiditySensorsLoThresholdTrapEnable 1.3.6.1.4.1.4779.1.6.11
Lo Threshold trap enable for all humidity sensors.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sBTAEnvironmentalAllAirflowSensorsHiThreshold 1.3.6.1.4.1.4779.1.6.12
Hi Threshold for all airflow sensors.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sBTAEnvironmentalAllAirflowSensorsLoThreshold 1.3.6.1.4.1.4779.1.6.13
Lo Threshold for all airflow sensors.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sBTAEnvironmentalAllAirflowSensorsHiThresholdTrapEnable 1.3.6.1.4.1.4779.1.6.14
Hi Threshold trap enable for all airflow sensors.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sBTAEnvironmentalAllAirflowSensorsLoThresholdTrapEnable 1.3.6.1.4.1.4779.1.6.15
Lo Threshold trap enable for all airflow sensors.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

communicationLost 1
SEVERE: Communication to the unit has been lost. Steps to reestablish communication are in progress. Argument is timeTicks when communication was lost.
TRAP-TYPE    

communicationEstablished 2
INFORMATION: Communication with the unit has been established. Argument is timeTicks when communication was established.
TRAP-TYPE    

outletOn 3
WARNING: The specified RPC outlet has turned on. If sBTAOutletIndex equals zero, then all outlets have turned on.
TRAP-TYPE    

outletOff 4
WARNING: The specified RPC outlet has turned off. If sBTAOutletIndex equals zero, then all outlets have turned off.
TRAP-TYPE    

outletReboot 5
WARNING: The specified RPC outlet has rebooted. If sBTAOutletIndex equals zero, then all outlets have rebooted.
TRAP-TYPE    

outletLocked 6
WARNING: The specified RPC outlet has been locked. If sBTAOutletIndex equals zero, then all outlets have been locked.
TRAP-TYPE    

outletUnlocked 7
WARNING: The specified RPC outlet has been unlocked. If sBTAOutletIndex equals zero, then all outlets have been unlocked.
TRAP-TYPE    

configChangeSNMP 8
WARNING: The SNMP configuration has been changed.
TRAP-TYPE    

configChangeOutlet 9
WARNING: The specified outlet has changed configuration.
TRAP-TYPE    

accessViolationConsole 10
WARNING: Someone has attempted to login via the console with the incorrect password.
TRAP-TYPE    

accessViolationNetwork 11
WARNING: Someone has attempted to login via the network with the incorrect password.
TRAP-TYPE    

userPasswordChange 12
WARNING: The password for the specified user has been changed.
TRAP-TYPE    

userAdded 13
WARNING: The specified user has been added.
TRAP-TYPE    

userLoggedIn 14
INFORMATIONAL: The specified user has logged in.
TRAP-TYPE    

temperatureThresholdViolation 15
WARNING: A temperature threshold has been violated. The argument is the rpc index.
TRAP-TYPE    

temperatureThresholdViolationCleared 16
INFORMATIONAL: A temperature threshold violated has been cleared. The argument is the rpc index.
TRAP-TYPE    

currentThresholdViolation 17
WARNING: The preset current threshold has been violated. The argument is the rpc index.
TRAP-TYPE    

currentThresholdViolationCleared 18
INFORMATIONAL: A current threshold violation has been cleared. The argument is the rpc index.
TRAP-TYPE    

resetModulesEvent 19
WARNING: A reset modules (RM) command has been executed.
TRAP-TYPE    

resetModulesComplete 20
WARNING: A reset modules (RM) command has been completed.
TRAP-TYPE    

errorExecutingSNMPCommand 21
WARNING: unable to execute SNMP command. String contains reason and command.
TRAP-TYPE    

fileTransferComplete 22
INFORMATIONAL: file transfer to unit complete.
TRAP-TYPE    

userTerminated 23
WARNING: user terminated. Argument specifies user.
TRAP-TYPE    

voltageOverThresholdViolation 24
WARNING: Over voltage. Argument specifies rpc.
TRAP-TYPE    

voltageOverThresholdViolationCleared 25
INFORMATIONAL: Over voltage cleared. Argument specifies rpc.
TRAP-TYPE    

voltageUnderThresholdViolation 26
WARNING: Under voltage. Argument specifies rpc.
TRAP-TYPE    

voltageUnderThresholdViolationCleared 27
INFORMATIONAL: Under voltage cleared. Argument specifies rpc.
TRAP-TYPE    

circuitBreakerAlarm 28
WARNING: Circuit breaker is blown. Argument specifies rpc.
TRAP-TYPE    

rpcFailureAlarm 29
WARNING: Unable to communicate to an RPC. Argument specifies port number of RPC.
TRAP-TYPE    

userDeleted 30
INFORMATIONAL: The specified user has logged in.
TRAP-TYPE    

warningThresholdViolation 31
TRAP-TYPE    

warningThresholdViolationClear 32
TRAP-TYPE    

emergencyThresholdViolation 33
TRAP-TYPE    

emergencyThresholdViolationClear 34
TRAP-TYPE    

circuitBreakerAlarmClearTrap 35
Circuit breaker has been reset. Argument specifies rpc.
TRAP-TYPE    

currentUnderThresholdViolation 36
WARNING: Low current. Argument specifies rpc.
TRAP-TYPE    

currentUnderThresholdViolationCleared 37
INFORMATIONAL: Low current cleared. Argument specifies rpc.
TRAP-TYPE    

voltageSourceChangeAlarm 38
WARNING: RPC voltage source has changed. Arguments specify modules index, current voltage source, and count of number of times source has been switched.
TRAP-TYPE    

sensorTempThreshHiAlarmTrap 39
WARNING: Hi threshold exceeded. Arguments specify module, sensor number
TRAP-TYPE    

sensorTempThreshHiAlarmClearedTrap 40
WARNING: Hi threshold alarm cleared. Arguments specify module, sensor number
TRAP-TYPE    

sensorTempThreshLoAlarmTrap 41
WARNING: Lo threshold alarm cleared. Arguments specify module, sensor number
TRAP-TYPE    

sensorTempThreshLoAlarmClearedTrap 42
WARNING: Lo threshold alarm cleared. Arguments specify module, sensor number
TRAP-TYPE    

sensorStateChangeTrap 43
WARNING: Sensor state (contact, detector, etc) has changed. Arguments specify module, sensor number
TRAP-TYPE    

configChangeSensor 44
WARNING: The specified environmental sensor has changed configuration.
TRAP-TYPE    

sensorTypeChange 45
WARNING: The specified environmental sensor is now a different type.
TRAP-TYPE