BroadworksMaintenance

File: BroadworksMaintenance.mib (36236 bytes)

Imported modules

SNMPv2-TC SNMPv2-CONF SNMPv2-SMI

Imported symbols

DisplayString MODULE-COMPLIANCE OBJECT-GROUP
enterprises MODULE-IDENTITY NOTIFICATION-TYPE
OBJECT-TYPE Gauge32 Counter32
Integer32 Unsigned32

Defined Types

BwSubComponentEntry  
SEQUENCE    
  bwSubComponentIndex Unsigned32
  bwSubComponentName DisplayString
  bwSubComponentInfo DisplayString

BwSoftwareVersionEntry  
SEQUENCE    
  bwSoftwareVersionIndex Unsigned32
  bwSoftwareVersionName DisplayString
  bwSoftwareVersionInstallDate DisplayString
  bwSoftwareVersionStatus INTEGER

BwSoftwarePatchEntry  
SEQUENCE    
  bwSoftwarePatchIndex Unsigned32
  bwSoftwarePatchName DisplayString
  bwSoftwarePatchInstallDate DisplayString
  bwSoftwarePatchState INTEGER
  bwSoftwarePatchBundle DisplayString

BwSoftwareThirdPartyEntry  
SEQUENCE    
  bwSoftwareThirdPartyIndex Unsigned32
  bwSoftwareThirdPartyName DisplayString
  bwSoftwareThirdPartyVersion DisplayString
  bwSoftwareThirdPartyStatus INTEGER

BwSoftwarePatchHistoryEntry  
SEQUENCE    
  bwSoftwarePatchHistoryIndex Unsigned32
  bwSoftwarePatchHistPatchName DisplayString
  bwSoftwarePatchHistTimeStamp DisplayString
  bwSoftwarePatchHistNewState INTEGER

BwSoftwarePatchImpactedFileEntry  
SEQUENCE    
  bwSoftwarePatchImpactedFileIndex Unsigned32
  bwSoftwarePatchImpactedFilePatchName DisplayString
  bwSoftwarePatchImpactedFileFileName DisplayString

BwManagedObjectsEntry  
SEQUENCE    
  bwManagedObjectsIndex Unsigned32
  bwManagedObjectsName DisplayString
  bwManagedObjectsProtocol DisplayString
  bwManagedObjectsType DisplayString
  bwManagedObjectsAdminState INTEGER
  bwManagedObjectsOperationalState INTEGER

BwCounterThresholdEntry  
SEQUENCE    
  bwCounterThresholdIndex Unsigned32
  bwCounterThresholdDescription DisplayString
  bwCounterThresholdName DisplayString
  bwCounterThresholdInitialValue Integer32
  bwCounterThresholdOffsetValue Integer32
  bwCounterThresholdCurrentValue Gauge32
  bwCounterThresholdSeverity INTEGER
  bwCounterThresholdControl INTEGER

BwGaugeThresholdEntry  
SEQUENCE    
  bwGaugeThresholdIndex Unsigned32
  bwGaugeThresholdDescription DisplayString
  bwGaugeThresholdName DisplayString
  bwGaugeThresholdNotifyLow Integer32
  bwGaugeThresholdNotifyHigh Integer32
  bwGaugeThresholdSeverity INTEGER
  bwGaugeThresholdControl INTEGER

BwAlarmThresholdEntry  
SEQUENCE    
  bwAlarmThresholdIndex Unsigned32
  bwAlarmThresholdName DisplayString
  bwAlarmThresholdMaxNumTrapsPerTimePeriod Integer32
  bwAlarmThresholdTimePeriodInSeconds Integer32
  bwAlarmThresholdProblemTextVarNum1 Integer32
  bwAlarmThresholdProblemTextVarNum2 Integer32
  bwAlarmThresholdProblemTextVarNum3 Integer32
  bwAlarmThresholdProblemTextVarNum4 Integer32
  bwAlarmThresholdProblemTextVarNum5 Integer32
  bwAlarmThresholdMinimumSeverity INTEGER
  bwAlarmThresholdControl INTEGER

Defined Values

broadsoft 1.3.6.1.4.1.6431
This is the System Management Information structure for the Broadsoft enterprise.
MODULE-IDENTITY    

broadworks 1.3.6.1.4.1.6431.1
OBJECT IDENTIFIER    

common 1.3.6.1.4.1.6431.1.1
OBJECT IDENTIFIER    

managedObjects 1.3.6.1.4.1.6431.1.1.2
OBJECT IDENTIFIER    

thresholds 1.3.6.1.4.1.6431.1.1.3
OBJECT IDENTIFIER    

reservedModule 1.3.6.1.4.1.6431.1.1.10
OBJECT IDENTIFIER    

bwMtcMibConformance 1.3.6.1.4.1.6431.1.1.20
OBJECT IDENTIFIER    

moServerModule 1.3.6.1.4.1.6431.1.1.2.1
OBJECT IDENTIFIER    

moSoftwareVersionModule 1.3.6.1.4.1.6431.1.1.2.2
OBJECT IDENTIFIER    

moDeviceModule 1.3.6.1.4.1.6431.1.1.2.3
OBJECT IDENTIFIER    

thCounterModule 1.3.6.1.4.1.6431.1.1.3.1
OBJECT IDENTIFIER    

thGaugeModule 1.3.6.1.4.1.6431.1.1.3.2
OBJECT IDENTIFIER    

thAlarmModule 1.3.6.1.4.1.6431.1.1.3.3
OBJECT IDENTIFIER    

bwServerType 1.3.6.1.4.1.6431.1.1.2.1.1
Gives the broadworks server type: { Application Server | Network Server | Media Server | Relay Server }
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

bwRedundancyType 1.3.6.1.4.1.6431.1.1.2.1.2
Gives the broadworks server redundancy type: { Primary | Secondary | NotRedundant }
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER nonRedundant(0), primary(1), seconday(2)  

bwActiveSoftwareVersion 1.3.6.1.4.1.6431.1.1.2.1.3
Gives the version of the active software version. An operator can change the active software version by setting this field.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

bwAdminState 1.3.6.1.4.1.6431.1.1.2.1.4
Server admin state. 0- Lock, 1- Locking, 2- Unlock, 3- ShuttingDown, 4- Stopped, 5- Forced Lock
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER lock(0), locking(1), unlock(2), shuttingDown(3), stopped(4), forceLock(5)  

bwOperationalState 1.3.6.1.4.1.6431.1.1.2.1.5
Server operational state. 0- Enabled, 1- Disabled
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(0), disabled(1)  

bwResetServer 1.3.6.1.4.1.6431.1.1.2.1.6
Remotely reset the BroadWorks server. The reset action kicks in when the counter is set to 1.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER set(0), reset(1), hardReset(2), revertReset(3), hardRevertReset(4)  

bwSubComponentTable 1.3.6.1.4.1.6431.1.1.2.1.7
This table exposes some key BroadWorks server sub components. It may or may not be empty depending on the server
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    BwSubComponentEntry

bwTargetSoftwareVersion 1.3.6.1.4.1.6431.1.1.2.1.8
Gives the target software version. If the server is reset, the active server software version will be updated.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

bwRevertBackupLocation 1.3.6.1.4.1.6431.1.1.2.1.9
Gives the location of the backup file to use if using the revert option of the reset command.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

bwSubComponentEntry 1.3.6.1.4.1.6431.1.1.2.1.7.1
This row contains information about a software component in the system
Status: current Access: not-accessible
OBJECT-TYPE    
  BwSubComponentEntry  

bwSubComponentIndex 1.3.6.1.4.1.6431.1.1.2.1.7.1.1
This integer represents the a software component index in the system
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

bwSubComponentName 1.3.6.1.4.1.6431.1.1.2.1.7.1.2
The name of an exposed subcomponent
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

bwSubComponentInfo 1.3.6.1.4.1.6431.1.1.2.1.7.1.3
Displays status information about the component
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

bwUpdateSoftwareVersionTable 1.3.6.1.4.1.6431.1.1.2.2.1
This counter is used to reload the installed software table. To do so, just set this register to 1 (reload)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER idle(0), reload(1)  

bwSoftwareVersionTable 1.3.6.1.4.1.6431.1.1.2.2.2
This table has an entry per software version installed on the server
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    BwSoftwareVersionEntry

bwSoftwarePatchTable 1.3.6.1.4.1.6431.1.1.2.2.3
This table has an entry per service packs installed for each sofware versions
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    BwSoftwarePatchEntry

bwSoftwareThirdPartyTable 1.3.6.1.4.1.6431.1.1.2.2.4
This table has an entry for third party software version used by the BroadWorks server
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    BwSoftwareThirdPartyEntry

bwSoftwarePatchHistoryTable 1.3.6.1.4.1.6431.1.1.2.2.5
This table contains information about all operation performed on patches.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    BwSoftwarePatchHistoryEntry

bwSoftwarePatchImpactedFileTable 1.3.6.1.4.1.6431.1.1.2.2.6
This table contains information about files modified by the patches applied on the system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    BwSoftwarePatchImpactedFileEntry

bwSoftwareVersionEntry 1.3.6.1.4.1.6431.1.1.2.2.2.1
This row contains information on a particular braodworks software version installed on the server
Status: current Access: not-accessible
OBJECT-TYPE    
  BwSoftwareVersionEntry  

bwSoftwareVersionIndex 1.3.6.1.4.1.6431.1.1.2.2.2.1.1
This integer represents the a group index in the system
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

bwSoftwareVersionName 1.3.6.1.4.1.6431.1.1.2.2.2.1.2
The name of a software load installed on the server.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

bwSoftwareVersionInstallDate 1.3.6.1.4.1.6431.1.1.2.2.2.1.3
Installation date for this software version.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

bwSoftwareVersionStatus 1.3.6.1.4.1.6431.1.1.2.2.2.1.4
The status of a software version.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER installed(0), active(1)  

bwSoftwarePatchEntry 1.3.6.1.4.1.6431.1.1.2.2.3.1
This row contains information on a particular braodworks patch installed on the server
Status: current Access: not-accessible
OBJECT-TYPE    
  BwSoftwarePatchEntry  

bwSoftwarePatchIndex 1.3.6.1.4.1.6431.1.1.2.2.3.1.1
This integer an index of a patch installed in the system
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

bwSoftwarePatchVersionName 1.3.6.1.4.1.6431.1.1.2.2.3.1.2
The name of a software load for which this patch applies. This field was obsoleted in BroadWorks release 14.0.
Status: obsolete Access: read-only
OBJECT-TYPE    
  DisplayString  

bwSoftwarePatchName 1.3.6.1.4.1.6431.1.1.2.2.3.1.3
Patch name.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

bwSoftwarePatchType 1.3.6.1.4.1.6431.1.1.2.2.3.1.4
Patch type. This field was obsoleted in BroadWorks release 14.0.
Status: obsolete Access: read-only
OBJECT-TYPE    
  DisplayString  

bwSoftwarePatchInstallDate 1.3.6.1.4.1.6431.1.1.2.2.3.1.5
This field was obsoleted in BroadWorks release 14.0.
Status: obsolete Access: read-only
OBJECT-TYPE    
  DisplayString  

bwSoftwarePatchState 1.3.6.1.4.1.6431.1.1.2.2.3.1.6
The state of the patch.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER installed(0), active(1), installedPendingActive(2), activePendingInstalled(3), deleted(4), installedMissingDependencies(5)  

bwSoftwarePatchOperation 1.3.6.1.4.1.6431.1.1.2.2.3.1.7
This field was obsoleted in BroadWorks release 14.0.
Status: obsolete Access: read-write
OBJECT-TYPE    
  INTEGER none(0), apply(1), remove(2), delete(3)  

bwSoftwarePatchBundle 1.3.6.1.4.1.6431.1.1.2.2.3.1.8
Patch Bundle name of the patch.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

bwSoftwareThirdPartyEntry 1.3.6.1.4.1.6431.1.1.2.2.4.1
This row contains information on an installed 3rd party software version
Status: current Access: not-accessible
OBJECT-TYPE    
  BwSoftwareThirdPartyEntry  

bwSoftwareThirdPartyIndex 1.3.6.1.4.1.6431.1.1.2.2.4.1.1
This integer represents the a group index in the system
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

bwSoftwareThirdPartyName 1.3.6.1.4.1.6431.1.1.2.2.4.1.2
The name of a software load for which this service pack applies
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

bwSoftwareThirdPartyVersion 1.3.6.1.4.1.6431.1.1.2.2.4.1.3
A 3rd party software version id
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

bwSoftwareThirdPartyStatus 1.3.6.1.4.1.6431.1.1.2.2.4.1.4
The status of a 3rd party software version.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER installed(0), active(1)  

bwSoftwarePatchHistoryEntry 1.3.6.1.4.1.6431.1.1.2.2.5.1
Entry of the patch history table containing history of operations applied to patches.
Status: current Access: not-accessible
OBJECT-TYPE    
  BwSoftwarePatchHistoryEntry  

bwSoftwarePatchHistoryIndex 1.3.6.1.4.1.6431.1.1.2.2.5.1.1
This integer an index of a patch operation history.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

bwSoftwarePatchHistPatchName 1.3.6.1.4.1.6431.1.1.2.2.5.1.2
The name of the patch against which the operation was applied.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

bwSoftwarePatchHistTimeStamp 1.3.6.1.4.1.6431.1.1.2.2.5.1.3
The time stamp of the patch operation.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

bwSoftwarePatchHistNewState 1.3.6.1.4.1.6431.1.1.2.2.5.1.4
The new state of the patch.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER installed(0), active(1), installedPendingActive(2), activePendingInstalled(3), deleted(4), installedMissingDependencies(5)  

bwSoftwarePatchImpactedFileEntry 1.3.6.1.4.1.6431.1.1.2.2.6.1
Entry of the patch impacted file table containing information about files modified by patches.
Status: current Access: not-accessible
OBJECT-TYPE    
  BwSoftwarePatchImpactedFileEntry  

bwSoftwarePatchImpactedFileIndex 1.3.6.1.4.1.6431.1.1.2.2.6.1.1
This integer an index of an impacted file/patch name.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

bwSoftwarePatchImpactedFilePatchName 1.3.6.1.4.1.6431.1.1.2.2.6.1.2
The name of the patch.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

bwSoftwarePatchImpactedFileFileName 1.3.6.1.4.1.6431.1.1.2.2.6.1.3
The name of an impacted file.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

bwManagedObjectsTable 1.3.6.1.4.1.6431.1.1.2.3.1
Table of all sub-managed objects under BroadWorks control
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    BwManagedObjectsEntry

bwManagedObjectsEntry 1.3.6.1.4.1.6431.1.1.2.3.1.1
This row contains information on a particular sub-managed object
Status: current Access: not-accessible
OBJECT-TYPE    
  BwManagedObjectsEntry  

bwManagedObjectsIndex 1.3.6.1.4.1.6431.1.1.2.3.1.1.1
This integer represents the a managed object index in the system
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

bwManagedObjectsName 1.3.6.1.4.1.6431.1.1.2.3.1.1.2
The name of a managed object controlled by BroadWorks
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

bwManagedObjectsProtocol 1.3.6.1.4.1.6431.1.1.2.3.1.1.3
The protocol supported by a managed object controlled by BroadWorks
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

bwManagedObjectsType 1.3.6.1.4.1.6431.1.1.2.3.1.1.4
The type of a managed object controlled by BroadWorks
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

bwManagedObjectsAdminState 1.3.6.1.4.1.6431.1.1.2.3.1.1.5
The administrative state of a managed object controlled by BroadWorks. 0- Lock, 1- locking, 2- Unlock
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER lock(0), locking(1), unlock(2)  

bwManagedObjectsOperationalState 1.3.6.1.4.1.6431.1.1.2.3.1.1.6
The operational state of a managed object controlled by BroadWorks. 0- Enabled, 1- Disabled
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(0), disabled(1)  

bwCounterThresholdTable 1.3.6.1.4.1.6431.1.1.3.1.1
Table of all the thresholds set against counters in the system
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    BwCounterThresholdEntry

bwCounterThresholdEntry 1.3.6.1.4.1.6431.1.1.3.1.1.1
This row contains information on a particular counter threshold
Status: current Access: not-accessible
OBJECT-TYPE    
  BwCounterThresholdEntry  

bwCounterThresholdIndex 1.3.6.1.4.1.6431.1.1.3.1.1.1.1
This integer represents the index of a counter threshold in the system
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

bwCounterThresholdDescription 1.3.6.1.4.1.6431.1.1.3.1.1.1.2
A description for this threshold.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

bwCounterThresholdName 1.3.6.1.4.1.6431.1.1.3.1.1.1.3
The name of a counter.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

bwCounterThresholdInitialValue 1.3.6.1.4.1.6431.1.1.3.1.1.1.4
The initial counter threshold value
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

bwCounterThresholdOffsetValue 1.3.6.1.4.1.6431.1.1.3.1.1.1.5
The offset to be added to the current threshold value once an alarm has been sent
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

bwCounterThresholdCurrentValue 1.3.6.1.4.1.6431.1.1.3.1.1.1.6
The threshold value at which the next alarm will be generated
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

bwCounterThresholdSeverity 1.3.6.1.4.1.6431.1.1.3.1.1.1.7
The severity of the alarm to be sent
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER informational(0), low(1), medium(2), high(3), critical(4)  

bwCounterThresholdControl 1.3.6.1.4.1.6431.1.1.3.1.1.1.8
This scalar controls the life cycle of the threshold. Setting this counter to create(3) using an unused index creates a row with the specified index. Setting it with an already used index has no effect. Setting this counter to delete(2) removes the entry.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER inactive(0), active(1), delete(2), create(3), invalid(4)  

bwGaugeThresholdTable 1.3.6.1.4.1.6431.1.1.3.2.1
Table of all the thresholds set against gauges in the system
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    BwGaugeThresholdEntry

bwGaugeThresholdEntry 1.3.6.1.4.1.6431.1.1.3.2.1.1
This row contains information on a particular gauge threshold
Status: current Access: not-accessible
OBJECT-TYPE    
  BwGaugeThresholdEntry  

bwGaugeThresholdIndex 1.3.6.1.4.1.6431.1.1.3.2.1.1.1
This integer represents the index of a gauge threshold in the system
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

bwGaugeThresholdDescription 1.3.6.1.4.1.6431.1.1.3.2.1.1.2
A description for this threshold.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

bwGaugeThresholdName 1.3.6.1.4.1.6431.1.1.3.2.1.1.3
The name of a gauge.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

bwGaugeThresholdNotifyLow 1.3.6.1.4.1.6431.1.1.3.2.1.1.4
The gauge value at which an alarm will be generated when the gauge value reaches or crosses the NotifyHigh level in a rising direction. Subsequent similar crossings of the NotifyHigh level will not generate an alarm until the gauge has reached or crossed the corresponding NotifyLow level.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

bwGaugeThresholdNotifyHigh 1.3.6.1.4.1.6431.1.1.3.2.1.1.5
The gauge value at which an alarm will be generated when the gauge value reaches or crosses the NotifyLow level in a falling direction. Subsequent similar crossings of the NotifyLow level will not generate an alarm until the gauge has reached or crossed the corresponding NotifyHigh level.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

bwGaugeThresholdSeverity 1.3.6.1.4.1.6431.1.1.3.2.1.1.6
The severity of the alarm to be sent
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER informational(0), low(1), medium(2), high(3), critical(4)  

bwGaugeThresholdControl 1.3.6.1.4.1.6431.1.1.3.2.1.1.7
This scalar controls the life cycle of the threshold. Setting this gauge to delete(2) removes the entry.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER inactive(0), active(1), delete(2), create(3), invalid(4)  

bwAlarmThresholdTable 1.3.6.1.4.1.6431.1.1.3.3.1
Table of all the thresholds set against alarms in the system
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    BwAlarmThresholdEntry

bwAlarmThresholdEntry 1.3.6.1.4.1.6431.1.1.3.3.1.1
This row contains information on a particular alarm threshold
Status: current Access: not-accessible
OBJECT-TYPE    
  BwAlarmThresholdEntry  

bwAlarmThresholdIndex 1.3.6.1.4.1.6431.1.1.3.3.1.1.1
This integer represents the index of an alarm threshold in the system
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

bwAlarmThresholdName 1.3.6.1.4.1.6431.1.1.3.3.1.1.2
The name of an alarm or DEFAULT if the threshold applies to all alarms in the system
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

bwAlarmThresholdMaxNumTrapsPerTimePeriod 1.3.6.1.4.1.6431.1.1.3.3.1.1.3
The maximum number of traps that the system outputs per sliding time period. If set to 0 (zero), the alarm is suppressed and the system does not output any trap for this alarm filter.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

bwAlarmThresholdTimePeriodInSeconds 1.3.6.1.4.1.6431.1.1.3.3.1.1.4
The time period used for threshold calculation, in seconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

bwAlarmThresholdProblemTextVarNum1 1.3.6.1.4.1.6431.1.1.3.3.1.1.5
To further refine a threshold, specify the position number of the variable data within the alarm problem text (1, 2, 3, etc.) that together with the alarm name, define the actual threshold. For example, if the alarm has five problem text variables: 1-deviceName, 2-deviceAddress, 3-devicePort, 4-errorType, 5-errorCode, and if the alarm threshold is to limit the number of traps for a given deviceName, devicePort, and errorType, then bwAlarmThresholdProblemTextVarNum1 should be set to 1, bwAlarmThresholdProblemTextVarNum2 should be set to 3, and bwAlarmThresholdProblemTextVarNum3 should be set to 4. To ignore filtering based on problem text variables, set to 0 (zero).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

bwAlarmThresholdProblemTextVarNum2 1.3.6.1.4.1.6431.1.1.3.3.1.1.6
To further refine a threshold, specify the position number of the variable data within the alarm problem text (1, 2, 3, etc.) that together with the alarm name, define the actual threshold. For example, if the alarm has five problem text variables: 1-deviceName, 2-deviceAddress, 3-devicePort, 4-errorType, 5-errorCode, and if the alarm threshold is to limit the number of traps for a given deviceName, devicePort, and errorType, then bwAlarmThresholdProblemTextVarNum1 should be set to 1, bwAlarmThresholdProblemTextVarNum2 should be set to 3, and bwAlarmThresholdProblemTextVarNum3 should be set to 4. To ignore filtering based on problem text variables, set to 0 (zero).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

bwAlarmThresholdProblemTextVarNum3 1.3.6.1.4.1.6431.1.1.3.3.1.1.7
To further refine a threshold, specify the position number of the variable data within the alarm problem text (1, 2, 3, etc.) that together with the alarm name, define the actual threshold. For example, if the alarm has five problem text variables: 1-deviceName, 2-deviceAddress, 3-devicePort, 4-errorType, 5-errorCode, and if the alarm threshold is to limit the number of traps for a given deviceName, devicePort, and errorType, then bwAlarmThresholdProblemTextVarNum1 should be set to 1, bwAlarmThresholdProblemTextVarNum2 should be set to 3, and bwAlarmThresholdProblemTextVarNum3 should be set to 4. To ignore filtering based on problem text variables, set to 0 (zero).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

bwAlarmThresholdProblemTextVarNum4 1.3.6.1.4.1.6431.1.1.3.3.1.1.8
To further refine a threshold, specify the position number of the variable data within the alarm problem text (1, 2, 3, etc.) that together with the alarm name, define the actual threshold. For example, if the alarm has five problem text variables: 1-deviceName, 2-deviceAddress, 3-devicePort, 4-errorType, 5-errorCode, and if the alarm threshold is to limit the number of traps for a given deviceName, devicePort, and errorType, then bwAlarmThresholdProblemTextVarNum1 should be set to 1, bwAlarmThresholdProblemTextVarNum2 should be set to 3, and bwAlarmThresholdProblemTextVarNum3 should be set to 4. To ignore filtering based on problem text variables, set to 0 (zero).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

bwAlarmThresholdProblemTextVarNum5 1.3.6.1.4.1.6431.1.1.3.3.1.1.9
To further refine a threshold, specify the position number of the variable data within the alarm problem text (1, 2, 3, etc.) that together with the alarm name, define the actual threshold. For example, if the alarm has five problem text variables: 1-deviceName, 2-deviceAddress, 3-devicePort, 4-errorType, 5-errorCode, and if the alarm threshold is to limit the number of traps for a given deviceName, devicePort, and errorType, then bwAlarmThresholdProblemTextVarNum1 should be set to 1, bwAlarmThresholdProblemTextVarNum2 should be set to 3, and bwAlarmThresholdProblemTextVarNum3 should be set to 4. To ignore filtering based on problem text variables, set to 0 (zero).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

bwAlarmThresholdMinimumSeverity 1.3.6.1.4.1.6431.1.1.3.3.1.1.10
This is the minimum alarm severity under which alarms start to be discarded.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER informational(0), low(1), medium(2), high(3), critical(4)  

bwAlarmThresholdControl 1.3.6.1.4.1.6431.1.1.3.3.1.1.11
This scalar controls the life cycle of the threshold. Setting this threshold to create(3) using an unused index creates a row with the specified index. Setting it with an already used index has no effect. Setting this threshold to delete(2) removes the entry.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER inactive(0), active(1), delete(2), create(3), invalid(4)  

bwReservedScalar 1.3.6.1.4.1.6431.1.1.10.1
This is a reserved counter
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notUsed(0)  

bwMtcMibGroups 1.3.6.1.4.1.6431.1.1.20.1
OBJECT IDENTIFIER    

bwMtcMibCompliancy 1.3.6.1.4.1.6431.1.1.20.2
OBJECT IDENTIFIER    

bwMoServerGroup 1.3.6.1.4.1.6431.1.1.20.1.1
This group defines managed object server attributes.
Status: current Access: read-only
OBJECT-GROUP    

bwMoSoftwareVersionsGroup 1.3.6.1.4.1.6431.1.1.20.1.2
This group defines the software version attributes for the managed object.
Status: current Access: read-only
OBJECT-GROUP    

bwMoDeviceGroup 1.3.6.1.4.1.6431.1.1.20.1.3
This group defines the counters used to manage the access or network devices monitored by this managed object.
Status: current Access: read-only
OBJECT-GROUP    

bwMoThresholdsGroup 1.3.6.1.4.1.6431.1.1.20.1.4
This group defines the threshold control for this managed object.
Status: current Access: read-only
OBJECT-GROUP    

bwMoReserveGroup 1.3.6.1.4.1.6431.1.1.20.1.10
MIB reserved section.
Status: current Access: read-only
OBJECT-GROUP    

bwMoBasicCompliance 1.3.6.1.4.1.6431.1.1.20.2.1
BroadWorks Common managed object MIB compliance
Status: current Access: read-only
MODULE-COMPLIANCE