CDM-570L
File:
CDM-570L.mib (12375 bytes)
Imported modules
Imported symbols
Defined Values
cdm570 |
1.3.6.1.4.1.6247.24 |
Module Identity for both CDM-570 L-Band and
IF-Band Satellite Modems. |
MODULE-IDENTITY |
|
|
|
cdm570LBUCOption |
1.3.6.1.4.1.6247.24.1.1.2.7 |
BUC option, where:
0 = None
1 = 100 watt
2 = 150 watt |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
none(0), buc100watt(1), buc150watt(2) |
|
cdm570LAlarmMaskBUC |
1.3.6.1.4.1.6247.24.1.2.7.9 |
BUC alarm mask, where:
0 = Unmasked
1 = Masked |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unmasked(0), masked(1) |
|
cdm570LAlarmMaskLNB |
1.3.6.1.4.1.6247.24.1.2.7.10 |
LNB alarm mask, where:
0 = Unmasked
1 = Masked |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unmasked(0), masked(1) |
|
cdm570LBUC |
1.3.6.1.4.1.6247.24.1.2.8.1 |
OBJECT IDENTIFIER |
|
|
|
cdm570LBUCDCPower |
1.3.6.1.4.1.6247.24.1.2.8.1.1 |
BUC power control, where:
0 = Disable BUC DC Power
1 = Enable BUC DC Power |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disable(0), enable(1) |
|
cdm570LBUCComms |
1.3.6.1.4.1.6247.24.1.2.8.1.2.1 |
Enables or disables communication, via the
FSK link, with an externally connected
Block Up Converted (BUC), where:
0 = Disabled
1 = Enabled |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disabled(0), enabled(1) |
|
cdm570LBUCAddress |
1.3.6.1.4.1.6247.24.1.2.8.1.2.2 |
Indicates the BUC address, between 1 and 15. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..15 |
|
cdm570LBUCRFOutput |
1.3.6.1.4.1.6247.24.1.2.8.1.2.3 |
Indicates BUC output enable, where:
0 = Off (output disabled)
1 = On (output enabled) |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
off(0), on(1) |
|
cdm570LBUC10MHzReference |
1.3.6.1.4.1.6247.24.1.2.8.1.3 |
Enables or disables the 10 MHz frequency
reference to the BUC, where:
0 = Disabled
1 = Enabled |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disabled(0), enabled(1) |
|
cdm570LBUCHighCurrentLimit |
1.3.6.1.4.1.6247.24.1.2.8.1.4.1 |
BUC high current limit, between 500 and 4000 mA. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
500..4000 |
|
cdm570LBUCLowCurrentLimit |
1.3.6.1.4.1.6247.24.1.2.8.1.4.2 |
BUC low current limit, between 0 and 3000 mA.
BUC low current limit must not exceed BUC high current limit. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..3000 |
|
cdm570LBUCLO |
1.3.6.1.4.1.6247.24.1.2.8.1.5 |
OBJECT IDENTIFIER |
|
|
|
cdm570LBUCLOFrequency |
1.3.6.1.4.1.6247.24.1.2.8.1.5.1 |
BUC transmit LO frequency in the range of 3000
to 65000 MHz.
Setting 0 disables this feature.
Terminal Frequency = BUC_LO +/- Tx_Frequency
(depending on LO mix). |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0 | 3000..65000 |
|
cdm570LBUCLOMix |
1.3.6.1.4.1.6247.24.1.2.8.1.5.2 |
BUC LO frequency mix, where:
0 = Low-side mix
1 = High-side mix |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
lowSideMix(0), highSideMix(1) |
|
cdm570LLNB |
1.3.6.1.4.1.6247.24.1.2.8.2 |
OBJECT IDENTIFIER |
|
|
|
cdm570LLNBDCPower |
1.3.6.1.4.1.6247.24.1.2.8.2.1 |
LNB power control, where:
0 = Off
1 = On, 13V LNB voltage
2 = On, 18V LNB voltage
3 = On, 24V LNB voltage |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
off(0), on13volts(1), on18volts(2), on24volts(3) |
|
cdm570LLNB10MHzReference |
1.3.6.1.4.1.6247.24.1.2.8.2.2 |
LNB 10MHz frequency reference, where:
0 = Disable LNB 10MHz reference
1 = Enable LNB 10MHz reference |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disable(0), enable(1) |
|
cdm570LLNBHighCurrentLimit |
1.3.6.1.4.1.6247.24.1.2.8.2.3.1 |
LNB upper alarm limit for current, between
50 and 600 mA. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
50..600 |
|
cdm570LLNBLowCurrentLimit |
1.3.6.1.4.1.6247.24.1.2.8.2.3.2 |
LNB lower alarm limit for current, between
10 and 400 mA. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
10..400 |
|
cdm570LLNBLO |
1.3.6.1.4.1.6247.24.1.2.8.2.4 |
OBJECT IDENTIFIER |
|
|
|
cdm570LLNBLOFrequency |
1.3.6.1.4.1.6247.24.1.2.8.2.4.1 |
LNB receieve LO frequency, in the range of
3000 to 65000 MHz.
Setting a 0 disables the feature.
Terminal Frequency = LNB_LO +/- Rx_Frequency
(depending on High/Low Mix) |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0 | 3000..65000 |
|
cdm570LLNBLOMix |
1.3.6.1.4.1.6247.24.1.2.8.2.4.2 |
LO frequency mix, where:
0 = Low-side mix
1 = High-side mix |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
lowSideMix(0), highSideMix(1) |
|
cdm570LODUAlarms |
1.3.6.1.4.1.6247.24.1.3.1.4 |
ODU Faults
Value Description of status parameter
0 No ODU faults
1 BUC PLL
3 BUC current
5 BUC voltage
7 LNB current
9 LNB voltage
11 BUC temperature
13 BUC checksum |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
noODUfaults(0), bucPLL(1), bucCurrent(3), bucVoltage(5), lnbCurrent(7), lnbVoltage(9), bucTemperature(11), bucChecksum(13) |
|
cdm570LBUCCurrent |
1.3.6.1.4.1.6247.24.1.3.6.1.1 |
Indicates the value of the BUC current,
between 0 and 9999 mA.
Units = mA. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..9999 |
|
cdm570LBUCVoltage |
1.3.6.1.4.1.6247.24.1.3.6.1.2 |
Indicates the value ofthe BUC voltage,
between 0 and 64 volts in 0.1 volts.
Units = 0.1 volts. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..640 |
|
cdm570LBUCTemperature |
1.3.6.1.4.1.6247.24.1.3.6.1.3 |
Indicates the BUC temperature in degrees Celsius.
If not available, response is -99.
Note: This query is only valid when FSK
and BUC power are turned On. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
-99..99 |
|
cdm570LBUCSoftwareVersion |
1.3.6.1.4.1.6247.24.1.3.6.1.4 |
Indicates the BUC software version,
between 1 and 15.
If not available, response is 0. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0 | 1..15 |
|
cdm570LBUCPLLAlarm |
1.3.6.1.4.1.6247.24.1.3.6.1.5 |
BUC PLL lock state, where:
0 = Locked
1 = Unlocked
9 = Unavailable |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
locked(0), unlocked(1), unavailable(9) |
|
cdm570LBUCPowerLevel |
1.3.6.1.4.1.6247.24.1.3.6.1.6 |
BUC output power level in 0.1 watts.
Units = 0.1 watts.
Returns 0 when FSK and BUC power are not enabled. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..999 |
|
cdm570LBUCTerminalTxFrequency |
1.3.6.1.4.1.6247.24.1.3.6.1.7 |
Terminal Tx Frequency = BUC_LO +/- Tx_Frequency
(depending on LO mix)
Units = 100 Hz
Resolution = 100 Hz
Returns 0 if BUC LO is zero. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..999999999 |
|
cdm570LLNBCurrent |
1.3.6.1.4.1.6247.24.1.3.6.2.1 |
Indicates the value of the LNB current,
between 0 and 999 mA. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..999 |
|
cdm570LLNBVoltage |
1.3.6.1.4.1.6247.24.1.3.6.2.2 |
Indicates the value of the LNB voltage,
between 0 and 30 volts.
Units = 0.1 volts
If not available, response is 0. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..300 |
|
cdm570LLNBTerminalRxFrequency |
1.3.6.1.4.1.6247.24.1.3.6.2.3 |
Terminal Rx frequency = LNB LO +/- Rx_Frequency
(depending on LO mix)
Units = 100 Hz
Resolution = 100 Hz
Returns 0 if LNB_LO is zero. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..999999999 |
|
cdm570LODUAlarm |
1.3.6.1.4.1.6247.24.2.0.4 |
CDM-570L BUC and LNB ODU Alarm Trap |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
cdm570LObjectsGroup |
1.3.6.1.4.1.6247.24.3.3.1 |
CDM-570L Objects Group. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
cdm570LNotificationsGroup |
1.3.6.1.4.1.6247.24.3.3.2 |
CDM-570L Notifications Group. |
Status: current |
Access: read-only |
NOTIFICATION-GROUP |
|
|
|
cdm570LCompliance |
1.3.6.1.4.1.6247.24.3.4.1 |
CDM-570L Compliance. |
Status: current |
Access: read-only |
MODULE-COMPLIANCE |
|
|
|