CIE1000-ALARM-MIB

File: CIE1000-ALARM-MIB.mib (11160 bytes)

Imported modules

SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
CISCO-IE1000-MIB CIE1000-TC

Imported symbols

NOTIFICATION-GROUP MODULE-COMPLIANCE OBJECT-GROUP
NOTIFICATION-TYPE MODULE-IDENTITY OBJECT-TYPE
TEXTUAL-CONVENTION cie1000SwitchMgmt CIE1000DisplayString
CIE1000RowEditorState TruthValue

Defined Types

CIE1000AlarmConfigEntry  
SEQUENCE    
  cie1000AlarmConfigAlarmName CIE1000DisplayString
  cie1000AlarmConfigExpression CIE1000DisplayString
  cie1000AlarmConfigAction CIE1000RowEditorState

CIE1000AlarmStatusEntry  
SEQUENCE    
  cie1000AlarmStatusAlarmName CIE1000DisplayString
  cie1000AlarmStatusSuppressed TruthValue
  cie1000AlarmStatusActive TruthValue
  cie1000AlarmStatusExposedActive TruthValue

CIE1000AlarmControlEntry  
SEQUENCE    
  cie1000AlarmControlAlarmName CIE1000DisplayString
  cie1000AlarmControlSuppress TruthValue

Defined Values

cie1000AlarmMib 1.3.6.1.4.1.9.9.832.1.136
This is a private mib for alarms
MODULE-IDENTITY    

cie1000AlarmMibObjects 1.3.6.1.4.1.9.9.832.1.136.1
OBJECT IDENTIFIER    

cie1000AlarmConfig 1.3.6.1.4.1.9.9.832.1.136.1.2
OBJECT IDENTIFIER    

cie1000AlarmConfigTable 1.3.6.1.4.1.9.9.832.1.136.1.2.1
The table is the list of configured alarms. The index is the name of the alarm
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CIE1000AlarmConfigEntry

cie1000AlarmConfigEntry 1.3.6.1.4.1.9.9.832.1.136.1.2.1.1
An index is a dotted name e.g. alarm.port.status
Status: current Access: not-accessible
OBJECT-TYPE    
  CIE1000AlarmConfigEntry  

cie1000AlarmConfigAlarmName 1.3.6.1.4.1.9.9.832.1.136.1.2.1.1.1
The name of the alarm
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  CIE1000DisplayString Size(0..99)  

cie1000AlarmConfigExpression 1.3.6.1.4.1.9.9.832.1.136.1.2.1.1.2
The expression defining the alarm.
Status: current Access: read-write
OBJECT-TYPE    
  CIE1000DisplayString Size(0..1023)  

cie1000AlarmConfigAction 1.3.6.1.4.1.9.9.832.1.136.1.2.1.1.100
Action
Status: current Access: read-write
OBJECT-TYPE    
  CIE1000RowEditorState  

cie1000AlarmConfigTableRowEditor 1.3.6.1.4.1.9.9.832.1.136.1.2.2
OBJECT IDENTIFIER    

cie1000AlarmConfigTableRowEditorAlarmName 1.3.6.1.4.1.9.9.832.1.136.1.2.2.1
The name of the alarm
Status: current Access: read-write
OBJECT-TYPE    
  CIE1000DisplayString Size(0..99)  

cie1000AlarmConfigTableRowEditorExpression 1.3.6.1.4.1.9.9.832.1.136.1.2.2.2
The expression defining the alarm.
Status: current Access: read-write
OBJECT-TYPE    
  CIE1000DisplayString Size(0..1023)  

cie1000AlarmConfigTableRowEditorAction 1.3.6.1.4.1.9.9.832.1.136.1.2.2.100
Action
Status: current Access: read-write
OBJECT-TYPE    
  CIE1000RowEditorState  

cie1000AlarmStatus 1.3.6.1.4.1.9.9.832.1.136.1.3
OBJECT IDENTIFIER    

cie1000AlarmStatusTable 1.3.6.1.4.1.9.9.832.1.136.1.3.1
The table is the list of alarm nodes. The index is the name of the alarm node
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CIE1000AlarmStatusEntry

cie1000AlarmStatusEntry 1.3.6.1.4.1.9.9.832.1.136.1.3.1.1
An index is a dotted name e.g. alarm.port.status
Status: current Access: not-accessible
OBJECT-TYPE    
  CIE1000AlarmStatusEntry  

cie1000AlarmStatusAlarmName 1.3.6.1.4.1.9.9.832.1.136.1.3.1.1.1
The name of the alarm
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  CIE1000DisplayString Size(0..99)  

cie1000AlarmStatusSuppressed 1.3.6.1.4.1.9.9.832.1.136.1.3.1.1.2
Indicates whether the alarm subtree is suppressed. When a subtree is suppressed, the status does not contribute to the state of the superior alarm tree.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

cie1000AlarmStatusActive 1.3.6.1.4.1.9.9.832.1.136.1.3.1.1.3
Indicates whether the alarm is active
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

cie1000AlarmStatusExposedActive 1.3.6.1.4.1.9.9.832.1.136.1.3.1.1.4
The exposed alarm status.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

cie1000AlarmControl 1.3.6.1.4.1.9.9.832.1.136.1.4
OBJECT IDENTIFIER    

cie1000AlarmControlTable 1.3.6.1.4.1.9.9.832.1.136.1.4.1
The table is the list of alarm nodes. The index is the name of the alarm node
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CIE1000AlarmControlEntry

cie1000AlarmControlEntry 1.3.6.1.4.1.9.9.832.1.136.1.4.1.1
An index is a dotted name e.g. alarm.port.status
Status: current Access: not-accessible
OBJECT-TYPE    
  CIE1000AlarmControlEntry  

cie1000AlarmControlAlarmName 1.3.6.1.4.1.9.9.832.1.136.1.4.1.1.1
The name of the alarm
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  CIE1000DisplayString Size(0..99)  

cie1000AlarmControlSuppress 1.3.6.1.4.1.9.9.832.1.136.1.4.1.1.2
Indicates whether to suppress the alarm subtree. When a subtree is suppressed, the status does not contribute to the state of the superior alarm tree.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

cie1000AlarmTrap 1.3.6.1.4.1.9.9.832.1.136.1.6
OBJECT IDENTIFIER    

cie1000AlarmTrapStatusAdd 1.3.6.1.4.1.9.9.832.1.136.1.6.1
This trap signals that a row has been added. The index(es) and value(s) of the row is included in the trap.
Status: current Access: read-write
NOTIFICATION-TYPE    

cie1000AlarmTrapStatusMod 1.3.6.1.4.1.9.9.832.1.136.1.6.2
This trap signals that one or more of the objects included in the trap has been updated.
Status: current Access: read-write
NOTIFICATION-TYPE    

cie1000AlarmTrapStatusDel 1.3.6.1.4.1.9.9.832.1.136.1.6.3
This trap signals that a row has been deleted. The index(es) of the row is included in the trap.
Status: current Access: read-write
NOTIFICATION-TYPE    

cie1000AlarmMibConformance 1.3.6.1.4.1.9.9.832.1.136.2
OBJECT IDENTIFIER    

cie1000AlarmMibCompliances 1.3.6.1.4.1.9.9.832.1.136.2.1
OBJECT IDENTIFIER    

cie1000AlarmMibGroups 1.3.6.1.4.1.9.9.832.1.136.2.2
OBJECT IDENTIFIER    

cie1000AlarmConfigTableInfoGroup 1.3.6.1.4.1.9.9.832.1.136.2.2.1
A collection of objects.
Status: current Access: read-write
OBJECT-GROUP    

cie1000AlarmConfigTableRowEditorInfoGroup 1.3.6.1.4.1.9.9.832.1.136.2.2.2
A collection of objects.
Status: current Access: read-write
OBJECT-GROUP    

cie1000AlarmStatusInfoGroup 1.3.6.1.4.1.9.9.832.1.136.2.2.3
A collection of objects.
Status: current Access: read-write
OBJECT-GROUP    

cie1000AlarmControlTableInfoGroup 1.3.6.1.4.1.9.9.832.1.136.2.2.4
A collection of objects.
Status: current Access: read-write
OBJECT-GROUP    

cie1000AlarmTrapStatusAddInfoGroup 1.3.6.1.4.1.9.9.832.1.136.2.2.5
Information group containing a trap.
Status: current Access: read-write
NOTIFICATION-GROUP    

cie1000AlarmTrapStatusModInfoGroup 1.3.6.1.4.1.9.9.832.1.136.2.2.6
Information group containing a trap.
Status: current Access: read-write
NOTIFICATION-GROUP    

cie1000AlarmTrapStatusDelInfoGroup 1.3.6.1.4.1.9.9.832.1.136.2.2.7
Information group containing a trap.
Status: current Access: read-write
NOTIFICATION-GROUP    

cie1000AlarmMibCompliance 1.3.6.1.4.1.9.9.832.1.136.2.1.1
The compliance statement for the implementation.
Status: current Access: read-write
MODULE-COMPLIANCE