CIENA-CES-TIME-SYNC-MIB

File: CIENA-CES-TIME-SYNC-MIB.mib (37909 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC CIENA-SMI
CIENA-TC CIENA-GLOBAL-MIB CIENA-CES-MODULE-MIB

Imported symbols

Integer32 Unsigned32 MacAddress
OBJECT-TYPE MODULE-IDENTITY NOTIFICATION-TYPE
DisplayString TEXTUAL-CONVENTION cienaCesConfig
cienaCesNotifications CienaGlobalState cienaGlobalSeverity
cienaGlobalMacAddress cienaCesModuleSlotName

Defined Types

SsmStratumLevel  
International and North American SSM Values
TEXTUAL-CONVENTION    
  INTEGER unknown(1), prc(2), ssua(3), ssub(4), sec(5), dnu(6), prs(7), stu(8), st2(9), tnc(10), st3e(11), st3(12), smc(13), st4(14), dus(15), prov(16)  

SyncInterfaceProtocol  
Interface protocol of an input/output reference.
TEXTUAL-CONVENTION    
  INTEGER unknown(1), bits(2), synce(3), ptp(4), gps(5), tdm(6)  

SyncBITSSignalMode  
Station Clock BITS signal mode.
TEXTUAL-CONVENTION    
  INTEGER modeunknown(1), modet1(2), modee1(3), modej1(4), mode2048khz(5), mode64kcc(6), mode6312khz(7)  

SyncBITSSignalFormat  
Station Clock BITS signal format. Esf and sf are applied to t1 signal only where as ccs and cas are applied to e1 signal.
TEXTUAL-CONVENTION    
  INTEGER unknown(1), cas(2), cascrc(3), esf(4), fas(5), fascrc(6), sf(7), e1crc(8), e1nocrc(9)  

SyncBITSSignalEncoding  
Encoding method used on T1/E1 BITS signal.
TEXTUAL-CONVENTION    
  INTEGER unknown(1), b8zs(2), ami(3), hdb3(4)  

SyncRefOperationalStatus  
Operational status of an input/output reference.
TEXTUAL-CONVENTION    
  INTEGER unknown(1), active(2), selected(3), lossofsignal(4), lossofframe(5), alarmindicationsignal(6), hardwarefault(7), hardwarenotconfigured(8), qlbelowthreshold(9), rxtimeout(10), notauthenticated(11), loopbacktx(12), loopbackrx(13), linkflap(14), notready(15), signalfailure(16), warmup(17), qlnotconfigured(18), noconnectivity(19), unsupportedhardware(20), unusable(21)  

SyncTimingType  
The timing domain; frequency, phase or time of day.
TEXTUAL-CONVENTION    
  INTEGER unknown(1), frequency(2), phase(3), tod(4), phaseandtod(5)  

SyncPTPRatePps  
The PTP rate in pps.
TEXTUAL-CONVENTION    
  INTEGER unknown(1), rate1over16pps(2), rate1over8pps(3), rate1over4pps(4), rate1over2pps(5), rate1pps(6), rate2pps(7), rate4pps(8), rate8pps(9), rate16pps(10), rate32pps(11), rate64pps(12), rate128pps(13)  

SyncGPSFreqClock  
The frequency of the clock for a GPS input/output reference, set when the reference is configured with a clock mode of frequency.
TEXTUAL-CONVENTION    
  INTEGER unknown(1), clock10mhz(2), clock2048khz(3), clock1544khz(4)  

SyncPTPEncapType  
The PTP encapsulation type.
TEXTUAL-CONVENTION    
  INTEGER unknown(1), udpoveripv4(2), udpoveripv6(3), ieee802dot3(4)  

CienaCesSyncInputProtectionGroupEntry  
SEQUENCE    
  cienaCesInputPGEntityId Integer32
  cienaCesInputPGEntityName DisplayString
  cienaCesInputPGPreferredReference DisplayString
  cienaCesInputPGSelectedReference DisplayString
  cienaCesInputPGForcedReference DisplayString
  cienaCesInputPGThresholdQualityLevel SsmStratumLevel
  cienaCesInputPGState CienaGlobalState
  cienaCesInputPGStateDuration DisplayString
  cienaCesInputPGReferenceSwitchCount Unsigned32
  cienaCesInputPGOperationalStatus INTEGER
  cienaCesInputPGTimingType SyncTimingType
  cienaCesInputPGOperationalQualityLevel SsmStratumLevel

CienaCesSyncInputProtectionUnitEntry  
SEQUENCE    
  cienaCesInputPUEntityId Integer32
  cienaCesInputPUEntityName DisplayString
  cienaCesInputPUPGEntityName DisplayString
  cienaCesInputPUTimingInterfaceName DisplayString
  cienaCesInputPUTimingInterfaceProtocol SyncInterfaceProtocol
  cienaCesInputPUUserPriority Unsigned32
  cienaCesInputPUOperationalQL SsmStratumLevel
  cienaCesInputPUForcedQL SsmStratumLevel
  cienaCesInputPUReceivedQL SsmStratumLevel
  cienaCesInputPUSsmEnabled INTEGER
  cienaCesInputPUOperationalStatus SyncRefOperationalStatus
  cienaCesInputPUBITSSignalMode SyncBITSSignalMode
  cienaCesInputPUBITSSignalFormat SyncBITSSignalFormat
  cienaCesInputPUBITSSignalEncoding SyncBITSSignalEncoding
  cienaCesInputPUUserOverridePriority Unsigned32
  cienaCesInputPUPTPEncapType SyncPTPEncapType
  cienaCesInputPUGPSClockMode SyncTimingType
  cienaCesInputPUGPSFreqClock SyncGPSFreqClock
  cienaCesInputPUBITSSignalSsmLocation INTEGER

CienaCesSyncOutputEntry  
SEQUENCE    
  cienaCesOutputEntityId Integer32
  cienaCesOutputEntityName DisplayString
  cienaCesOutputTimingInterfaceName DisplayString
  cienaCesOutputTimingInterfaceProtocol SyncInterfaceProtocol
  cienaCesOutputOperationalQL SsmStratumLevel
  cienaCesOutputOperationalStatus SyncRefOperationalStatus
  cienaCesOutputBITSSignalMode SyncBITSSignalMode
  cienaCesOutputBITSSignalFormat SyncBITSSignalFormat
  cienaCesOutputBITSSignalEncoding SyncBITSSignalEncoding
  cienaCesOutputBITSSignalLineBuildout INTEGER
  cienaCesOutputBITSSignalSsmLocation INTEGER
  cienaCesOutputGPSClockMode SyncTimingType
  cienaCesOutputGPSFreqClock SyncGPSFreqClock
  cienaCesOutputPTPEncapType SyncPTPEncapType

Defined Values

cienaCesTimeSyncMIB 1.3.6.1.4.1.1271.2.1.28
This MIB module defines objects and associated notifications for the System Timing feature.
MODULE-IDENTITY    

cienaCesTimeSyncMIBObjects 1.3.6.1.4.1.1271.2.1.28.1
OBJECT IDENTIFIER    

cienaCesTimeSyncObjects 1.3.6.1.4.1.1271.2.1.28.1.1
OBJECT IDENTIFIER    

cienaCesTimeSyncMIBNotificationPrefix 1.3.6.1.4.1.1271.2.2.28
OBJECT IDENTIFIER    

cienaCesTimeSyncMIBNotifications 1.3.6.1.4.1.1271.2.2.28.0
OBJECT IDENTIFIER    

cienaCesSyncAdminState 1.3.6.1.4.1.1271.2.1.28.1.1.1
Globally enable/disable Sync
Status: current Access: read-only
OBJECT-TYPE    
  CienaGlobalState  

cienaCesSyncOptionType 1.3.6.1.4.1.1271.2.1.28.1.1.2
Indication of which set of SSM values being used. Option 1 is for International standard and Option 2 is for North American.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), option1(2), option2(3)  

cienaCesSyncRevertiveMode 1.3.6.1.4.1.1271.2.1.28.1.1.3
Revertive mode.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), revertive(2), nonrevertive(3)  

cienaCesSyncWaitToRestoreTimer 1.3.6.1.4.1.1271.2.1.28.1.1.4
User configured timer for a timing reference source to wait before transitioning from bad to good clock signal.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

cienaCesSyncHoldoverInterval 1.3.6.1.4.1.1271.2.1.28.1.1.10
User configured interval after which holdover quality level changes.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), indefinite(2), twentyfourhours(3)  

cienaCesSyncInputProtectionGroupTable 1.3.6.1.4.1.1271.2.1.28.1.1.5
A table of protection groups for input timing reference.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CienaCesSyncInputProtectionGroupEntry

cienaCesSyncInputProtectionGroupEntry 1.3.6.1.4.1.1271.2.1.28.1.1.5.1
An entry in this table represents information on a protection group for input timing reference
Status: current Access: not-accessible
OBJECT-TYPE    
  CienaCesSyncInputProtectionGroupEntry  

cienaCesInputPGEntityId 1.3.6.1.4.1.1271.2.1.28.1.1.5.1.1
The unique identifier of this input protection group.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1  

cienaCesInputPGEntityName 1.3.6.1.4.1.1271.2.1.28.1.1.5.1.2
The unique name of this input protection group.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..31)  

cienaCesInputPGPreferredReference 1.3.6.1.4.1.1271.2.1.28.1.1.5.1.3
Preferred timing reference source, configured by users.
Status: deprecated Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..31)  

cienaCesInputPGSelectedReference 1.3.6.1.4.1.1271.2.1.28.1.1.5.1.4
System selected timing reference source.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..31)  

cienaCesInputPGForcedReference 1.3.6.1.4.1.1271.2.1.28.1.1.5.1.5
System was forced to used this timing reference source.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..31)  

cienaCesInputPGThresholdQualityLevel 1.3.6.1.4.1.1271.2.1.28.1.1.5.1.6
Specified Quality Level threshold for a reference source being selected.
Status: current Access: read-only
OBJECT-TYPE    
  SsmStratumLevel  

cienaCesInputPGState 1.3.6.1.4.1.1271.2.1.28.1.1.5.1.7
Configured state of this protection group.
Status: deprecated Access: read-only
OBJECT-TYPE    
  CienaGlobalState  

cienaCesInputPGStateDuration 1.3.6.1.4.1.1271.2.1.28.1.1.5.1.8
Duration since the system entered current state.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..31)  

cienaCesInputPGReferenceSwitchCount 1.3.6.1.4.1.1271.2.1.28.1.1.5.1.9
The number of timing reference switching since the system stared up.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

cienaCesInputPGOperationalStatus 1.3.6.1.4.1.1271.2.1.28.1.1.5.1.10
Operational status of this protection group.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), freerun(2), holdover(3), locked(4), acquiringlock(5), holdoverexpired(6)  

cienaCesInputPGTimingType 1.3.6.1.4.1.1271.2.1.28.1.1.5.1.11
The timing domain (freq/phase/tod) that this protection group belongs to.
Status: current Access: read-only
OBJECT-TYPE    
  SyncTimingType  

cienaCesInputPGOperationalQualityLevel 1.3.6.1.4.1.1271.2.1.28.1.1.5.1.12
Operational Quality Level of the protection group.
Status: current Access: read-only
OBJECT-TYPE    
  SsmStratumLevel  

cienaCesSyncInputProtectionUnitTable 1.3.6.1.4.1.1271.2.1.28.1.1.6
A table of protection units for input timing reference.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CienaCesSyncInputProtectionUnitEntry

cienaCesSyncInputProtectionUnitEntry 1.3.6.1.4.1.1271.2.1.28.1.1.6.1
An entry in this table represents information on a protection unit for input timing reference.
Status: current Access: not-accessible
OBJECT-TYPE    
  CienaCesSyncInputProtectionUnitEntry  

cienaCesInputPUEntityId 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.1
The unique identifier of this input protection unit.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..48  

cienaCesInputPUEntityName 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.2
The unique name of this input protection unit.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..31)  

cienaCesInputPUPGEntityName 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.3
The identifier of the input protection group(s) which this input protection unit belongs to.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

cienaCesInputPUTimingInterfaceName 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.4
The interface name of this input protection unit.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..31)  

cienaCesInputPUTimingInterfaceProtocol 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.5
The interface protocol of this input protection unit.
Status: current Access: read-only
OBJECT-TYPE    
  SyncInterfaceProtocol  

cienaCesInputPUUserPriority 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.6
The user configured priority of this input protection unit.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

cienaCesInputPUOperationalQL 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.7
Operational clock quality level of this input protection unit.
Status: current Access: read-only
OBJECT-TYPE    
  SsmStratumLevel  

cienaCesInputPUForcedQL 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.8
User configured clock quality level that this input protection unit is forced to operate at.
Status: current Access: read-only
OBJECT-TYPE    
  SsmStratumLevel  

cienaCesInputPUReceivedQL 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.9
Actual received clock quality level of this input protection unit.
Status: current Access: read-only
OBJECT-TYPE    
  SsmStratumLevel  

cienaCesInputPUSsmEnabled 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.10
Enable/disable reading of actual received clock quality level for this input protection unit.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), disabled(2), enabled(3)  

cienaCesInputPUOperationalStatus 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.11
Operational status of this input protection unit.
Status: current Access: read-only
OBJECT-TYPE    
  SyncRefOperationalStatus  

cienaCesInputPUBITSSignalMode 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.12
BITS Signal Mode, set if BITS signal is used as a protection unit.
Status: current Access: read-only
OBJECT-TYPE    
  SyncBITSSignalMode  

cienaCesInputPUBITSSignalFormat 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.13
BITS Signal Format, set if BITS signal is used as a protection unit.
Status: current Access: read-only
OBJECT-TYPE    
  SyncBITSSignalFormat  

cienaCesInputPUBITSSignalEncoding 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.14
BITS Signal encoding, set if BITS signal is used as a protection unit.
Status: current Access: read-only
OBJECT-TYPE    
  SyncBITSSignalEncoding  

cienaCesInputPUUserOverridePriority 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.15
The user configured override-priority of this input protection unit.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

cienaCesInputPUPTPEncapType 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.16
PTP Encapsulation Type, set if a PTP input is used as a protection unit.
Status: current Access: read-only
OBJECT-TYPE    
  SyncPTPEncapType  

cienaCesInputPUGPSClockMode 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.17
GPS clock mode, set if a GPS input is used as a protection unit.
Status: current Access: read-only
OBJECT-TYPE    
  SyncTimingType  

cienaCesInputPUGPSFreqClock 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.18
GPS frequency clock, set if a GPS input is used as a protection unit and the cienaCesInputPUGPSClockMode is set to frequency.
Status: current Access: read-only
OBJECT-TYPE    
  SyncGPSFreqClock  

cienaCesInputPUBITSSignalSsmLocation 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.19
BITS Signal Ssm Location, set if BITS signal is used as an input reference.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), sa4(2), sa5(3), sa6(4), sa7(5), sa8(6)  

cienaCesSyncOutputTable 1.3.6.1.4.1.1271.2.1.28.1.1.7
A table of output timing references.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CienaCesSyncOutputEntry

cienaCesSyncOutputEntry 1.3.6.1.4.1.1271.2.1.28.1.1.7.1
An entry in this table represents information for an output timing reference.
Status: current Access: not-accessible
OBJECT-TYPE    
  CienaCesSyncOutputEntry  

cienaCesOutputEntityId 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.1
The unique identifier of this output reference entity.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..48  

cienaCesOutputEntityName 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.2
The unique name of this output reference entity.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..31)  

cienaCesOutputTimingInterfaceName 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.3
The interface name of this output reference.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..31)  

cienaCesOutputTimingInterfaceProtocol 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.4
The interface protocol of this output reference.
Status: current Access: read-only
OBJECT-TYPE    
  SyncInterfaceProtocol  

cienaCesOutputOperationalQL 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.5
Operational clock quality level of this output reference.
Status: current Access: read-only
OBJECT-TYPE    
  SsmStratumLevel  

cienaCesOutputOperationalStatus 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.6
Operational status of this output reference.
Status: current Access: read-only
OBJECT-TYPE    
  SyncRefOperationalStatus  

cienaCesOutputBITSSignalMode 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.7
BITS Signal Mode, set if BITS signal is used as an output reference.
Status: current Access: read-only
OBJECT-TYPE    
  SyncBITSSignalMode  

cienaCesOutputBITSSignalFormat 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.8
BITS Signal Format, set if BITS signal is used as an output reference.
Status: current Access: read-only
OBJECT-TYPE    
  SyncBITSSignalFormat  

cienaCesOutputBITSSignalEncoding 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.9
BITS Signal encoding, set if BITS signal is used as an output reference.
Status: current Access: read-only
OBJECT-TYPE    
  SyncBITSSignalEncoding  

cienaCesOutputBITSSignalLineBuildout 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.10
BITS Signal Line Buildout, set if BITS signal is used as an output reference.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), lbo133(2), lbo266(3), lbo399(4), lbo533(5), lbo655(6)  

cienaCesOutputBITSSignalSsmLocation 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.11
BITS Signal Ssm Location, set if BITS signal is used as an output reference.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), sa4(2), sa5(3), sa6(4), sa7(5), sa8(6)  

cienaCesOutputGPSClockMode 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.12
GPS clock mode, set if a GPS signal is used as an output reference.
Status: current Access: read-only
OBJECT-TYPE    
  SyncTimingType  

cienaCesOutputGPSFreqClock 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.13
GPS frequency clock, set if a GPS signal is used as an output reference and the cienaCesOutputGPSClockMode is set to frequency.
Status: current Access: read-only
OBJECT-TYPE    
  SyncGPSFreqClock  

cienaCesOutputPTPEncapType 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.14
PTP Encapsulation Type, set if a PTP output is used as an output reference.
Status: current Access: read-only
OBJECT-TYPE    
  SyncPTPEncapType  

cienaCesSyncPTPConfig 1.3.6.1.4.1.1271.2.1.28.1.1.8
OBJECT IDENTIFIER    

cienaCesSyncPTPGlobalConfig 1.3.6.1.4.1.1271.2.1.28.1.1.8.1
OBJECT IDENTIFIER    

cienaCesSyncPTPInputConfig 1.3.6.1.4.1.1271.2.1.28.1.1.8.2
OBJECT IDENTIFIER    

cienaCesSyncPTPOutputConfig 1.3.6.1.4.1.1271.2.1.28.1.1.8.3
OBJECT IDENTIFIER    

cienaCesSyncPTPAddrMode 1.3.6.1.4.1.1271.2.1.28.1.1.8.1.1
PTP Address Mode.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), unicast(2), multicast(3)  

cienaCesSyncPTPTagPriority 1.3.6.1.4.1.1271.2.1.28.1.1.8.1.2
PTP tag priority
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

cienaCesSyncPTPProtocolVersion 1.3.6.1.4.1.1271.2.1.28.1.1.8.1.3
PTP Protocol Version.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), v2(2)  

cienaCesSyncPTPProfileVersion 1.3.6.1.4.1.1271.2.1.28.1.1.8.1.4
PTP Profile Version.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), version1dot0(2)  

cienaCesSyncPTPProfileIdentifier 1.3.6.1.4.1.1271.2.1.28.1.1.8.1.5
PTP profile identifier address.
Status: current Access: read-only
OBJECT-TYPE    
  MacAddress  

cienaCesSyncPTPDomainNumber 1.3.6.1.4.1.1271.2.1.28.1.1.8.1.6
PTP domain number.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

cienaCesSyncPTPClockType 1.3.6.1.4.1.1271.2.1.28.1.1.8.1.7
PTP Clock Type.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), ocslave(2), bc(3)  

cienaCesSyncPTPClockID 1.3.6.1.4.1.1271.2.1.28.1.1.8.1.8
PTP clock identifier.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..31)  

cienaCesSyncPTPDscp 1.3.6.1.4.1.1271.2.1.28.1.1.8.1.9
PTP DSCP.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

cienaCesSyncPTPInputUnicastReqDuration 1.3.6.1.4.1.1271.2.1.28.1.1.8.2.1
PTP input unicast request duration in seconds.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

cienaCesSyncPTPInputAnnounceRxLossNum 1.3.6.1.4.1.1271.2.1.28.1.1.8.2.2
PTP input announce Rx loss num (announce intervals).
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

cienaCesSyncPTPInputAnnounceTxRateReq 1.3.6.1.4.1.1271.2.1.28.1.1.8.2.3
PTP input announce Tx rate request (pps).
Status: current Access: read-only
OBJECT-TYPE    
  SyncPTPRatePps  

cienaCesSyncPTPInputSyncTxRateReq 1.3.6.1.4.1.1271.2.1.28.1.1.8.2.4
PTP input sync Tx rate request (pps).
Status: current Access: read-only
OBJECT-TYPE    
  SyncPTPRatePps  

cienaCesSyncPTPInputDelayReqTxRate 1.3.6.1.4.1.1271.2.1.28.1.1.8.2.5
PTP input delay request Tx rate (pps).
Status: current Access: read-only
OBJECT-TYPE    
  SyncPTPRatePps  

cienaCesSyncPTPOutputMaxSlaveSessions 1.3.6.1.4.1.1271.2.1.28.1.1.8.3.1
Maximum number of allowed PTP slave sessions for PTP outputs.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

cienaCesSyncPTPOutputTimestampMode 1.3.6.1.4.1.1271.2.1.28.1.1.8.3.2
PTP timestamp mode.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), onestep(2), twostep(3)  

cienaCesSyncGPSConfig 1.3.6.1.4.1.1271.2.1.28.1.1.9
OBJECT IDENTIFIER    

cienaCesSyncGPSOutputConfig 1.3.6.1.4.1.1271.2.1.28.1.1.9.1
OBJECT IDENTIFIER    

cienaCesSyncGPSOutput1ppsPulseWidth 1.3.6.1.4.1.1271.2.1.28.1.1.9.1.1
The 1pps pulse width, in microseconds, for GPS output references (applicable to phase).
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

cienaCesSyncModuleSlotClockStatus 1.3.6.1.4.1.1271.2.1.28.1.1.11
Lock status of module slot.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  INTEGER unknown(1), lossoflock(2), lockedtoprimaryctx(3), lockedtosecondaryctx(4)  

cienaCesSyncInputPUStateChangeNotification 1.3.6.1.4.1.1271.2.2.28.0.1
Sent when a configured timing reference transitions states.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

cienaCesSyncInputProtectionGroupStateChangeNotification 1.3.6.1.4.1.1271.2.2.28.0.2
Sent when a configured protection-group transitions states.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

cienaCesSyncModuleSlotClockStateChangeNotification 1.3.6.1.4.1.1271.2.2.28.0.3
Sent when a slot other than the primary CTX experiences a timing state change. Only applicable in SAOS 8.x.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE