CISCO-CALL-TRACKER-MODEM-MIB

File: CISCO-CALL-TRACKER-MODEM-MIB.mib (53728 bytes)

Imported modules

SNMPv2-SMI SNMPv2-CONF SNMPv2-TC
CISCO-SMI CISCO-CALL-TRACKER-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Counter32
Gauge32 Integer32 Unsigned32
MODULE-COMPLIANCE OBJECT-GROUP DisplayString
TEXTUAL-CONVENTION ciscoMgmt cctActiveCallId
cctHistoryIndex

Defined Types

CctmModulation  
Represents possible modulation standards other - Modulation other than those identified bell103a - bell212a - v21 - v22 - v22bis - v32 - v32bis - vfc - v34 - v17 - v29 - v33 - k56flex - v23 - v32terbo - v34plus - v90 - v27ter - v110 -
TEXTUAL-CONVENTION    
  INTEGER other(1), bell103a(2), bell212a(3), v21(4), v22(5), v22bis(6), v32(7), v32bis(8), vfc(9), v34(10), v17(11), v29(12), v33(13), k56flex(14), v23(15), v32terbo(16), v34plus(17), v90(18), v27ter(19), v110(20)  

CctmECProtocol  
Represents possible error correction protocols normal - No EC present direct - mnp - lapmV42 - syncMode - asyncMode - No EC present, same as normal(1) ara1 - ARA 1.0 ara2 - ARA 2.0 other - EC protocol other than those identified
TEXTUAL-CONVENTION    
  INTEGER normal(1), direct(2), mnp(3), lapmV42(4), syncMode(5), asyncMode(6), ara1(7), ara2(8), other(9)  

CctmDataCompression  
Represents possible data compression protocols none - No Data Compression present v42bisTx - V.42bis in transmit direction only v42bisRx - V.42bis in receive direction only v42bisBoth - V.42bis in receive and transmit directions mnp5 - v44Tx - V.44 in transmit direction only v44Rx - V.44 in receive direction only v44Both - V.44 in receive and transmit directions
TEXTUAL-CONVENTION    
  INTEGER none(1), v42bisTx(2), v42bisRx(3), v42bisBoth(4), mnp5(5), v44Tx(6), v44Rx(7), v44Both(8)  

CctmActiveEntry  
SEQUENCE    
  cctmActiveProjectedMaxRxRate Unsigned32
  cctmActiveProjectedMaxTxRate Unsigned32
  cctmActiveRxRate Unsigned32
  cctmActiveTxRate Unsigned32
  cctmActiveAttemptedModulation CctmModulation
  cctmActiveInitialModulation CctmModulation
  cctmActiveModulation CctmModulation
  cctmActiveAttemptedECProtocol CctmECProtocol
  cctmActiveECProtocol CctmECProtocol
  cctmActiveSupportedDC BITS
  cctmActiveDataCompression CctmDataCompression
  cctmActiveRxHighWatermark Gauge32
  cctmActiveRxLowWatermark Gauge32
  cctmActiveTxHighWatermark Gauge32
  cctmActiveTxLowWatermark Gauge32
  cctmActiveLocalUpRateShifts Counter32
  cctmActiveLocalDownRateShifts Counter32
  cctmActiveRemoteUpRateShifts Counter32
  cctmActiveRemoteDownRateShifts Counter32
  cctmActiveRateShiftFailures Counter32
  cctmActiveLocalRetrains Counter32
  cctmActiveRemoteRetrains Counter32
  cctmActiveRetrainFailures Counter32
  cctmActiveRxLinkOctets Counter32
  cctmActiveTxLinkOctets Counter32
  cctmActiveRxECFrames Counter32
  cctmActiveTxECFrames Counter32
  cctmActiveRxECNAKs Counter32
  cctmActiveTxECNAKs Counter32
  cctmActiveRxECFramesBad Counter32
  cctmActiveECFramesResent Counter32
  cctmActiveECLinkTimeouts Counter32
  cctmActiveRxCharLost Counter32

CctmHistoryEntry  
SEQUENCE    
  cctmHistoryProjectedMaxRxRate Unsigned32
  cctmHistoryProjectedMaxTxRate Unsigned32
  cctmHistoryFinalRxRate Unsigned32
  cctmHistoryFinalTxRate Unsigned32
  cctmHistoryAttemptedModulation CctmModulation
  cctmHistoryInitialModulation CctmModulation
  cctmHistoryFinalModulation CctmModulation
  cctmHistoryAttemptedECProtocol CctmECProtocol
  cctmHistoryECProtocol CctmECProtocol
  cctmHistorySupportedDC BITS
  cctmHistoryDataCompression CctmDataCompression
  cctmHistoryRxHighWatermark Gauge32
  cctmHistoryRxLowWatermark Gauge32
  cctmHistoryTxHighWatermark Gauge32
  cctmHistoryTxLowWatermark Gauge32
  cctmHistoryLocalUpRateShifts Counter32
  cctmHistoryLocalDownRateShifts Counter32
  cctmHistoryRemoteUpRateShifts Counter32
  cctmHistoryRemoteDownRateShifts Counter32
  cctmHistoryRateShiftFailures Counter32
  cctmHistoryLocalRetrains Counter32
  cctmHistoryRemoteRetrains Counter32
  cctmHistoryRetrainFailures Counter32
  cctmHistoryRxLinkOctets Counter32
  cctmHistoryTxLinkOctets Counter32
  cctmHistoryRxECFrames Counter32
  cctmHistoryTxECFrames Counter32
  cctmHistoryRxECNAKs Counter32
  cctmHistoryTxECNAKs Counter32
  cctmHistoryRxECFramesBad Counter32
  cctmHistoryECFramesResent Counter32
  cctmHistoryECLinkTimeouts Counter32
  cctmHistoryRxCharLost Counter32
  cctmHistoryDisconnectReason Unsigned32
  cctmHistoryDisconnectReasonText DisplayString

CctmXHistoryEntry  
SEQUENCE    
  cctmXHistoryRxECInfoFrameSize Unsigned32
  cctmXHistoryTxECInfoFrameSize Unsigned32
  cctmXHistoryRxECWindowSize Unsigned32
  cctmXHistoryTxECWindowSize Unsigned32
  cctmXHistoryRxLevel Integer32
  cctmXHistoryTxLevel Integer32
  cctmXHistoryConstellation INTEGER
  cctmXHistoryV90Status INTEGER
  cctmXHistoryV90Failure INTEGER
  cctmXHistoryV90ClientId Unsigned32
  cctmXHistoryECWindowClosures Counter32

Defined Values

ciscoCallTrackerModemMIB 1.3.6.1.4.1.9.9.165
This MIB module provides modem call related data for tracking the progress and status of a call. This module extends tables defined in the MIB module ciscoCallTrackerMIB in CISCO-CALL-TRACKER-MIB.
MODULE-IDENTITY    

cctmMIBObjects 1.3.6.1.4.1.9.9.165.1
OBJECT IDENTIFIER    

cctmActive 1.3.6.1.4.1.9.9.165.1.1
OBJECT IDENTIFIER    

cctmHistory 1.3.6.1.4.1.9.9.165.1.2
OBJECT IDENTIFIER    

cctmActiveTable 1.3.6.1.4.1.9.9.165.1.1.1
This table contains entries for active calls in the system which utilize modem resources. It contains general modem session attributes and statistics at the modem link and modem protocol layers. The table extends the cctActiveTable, using the same index, cctActiveCallId. There are no entries for calls not requiring modem services.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CctmActiveEntry

cctmActiveEntry 1.3.6.1.4.1.9.9.165.1.1.1.1
The information regarding a single call. Entries are created and deleted in sync with the entries in cctActiveTable, if the call utilizes modem service.
Status: current Access: not-accessible
OBJECT-TYPE    
  CctmActiveEntry  

cctmActiveProjectedMaxRxRate 1.3.6.1.4.1.9.9.165.1.1.1.1.1
Maximum received rate local modem informs remote modem it will support based on initial negotiations. The remote modem will not attempt to transmit at rates greater than what the local modem will accept. The initial negotiated receive rate is in cctActiveRxRate.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

cctmActiveProjectedMaxTxRate 1.3.6.1.4.1.9.9.165.1.1.1.1.2
Maximum rate the remote modem indicates it can accept based on initial negotiations. The local modem will not attempt to transmit at rates above what the remote modem will accept. The initial negotiated transmit rate is in cctActiveTxRate.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

cctmActiveRxRate 1.3.6.1.4.1.9.9.165.1.1.1.1.3
Current receive data rate for this call. The value of this object will be the same as reported in cmRXRate from CISCO-MODEM-MGMT-MIB while the call is active.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

cctmActiveTxRate 1.3.6.1.4.1.9.9.165.1.1.1.1.4
Current transmit data rate for this call. The value of this object will be the same as reported in cmTXRate from CISCO-MODEM-MGMT-MIB while the call is active.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

cctmActiveAttemptedModulation 1.3.6.1.4.1.9.9.165.1.1.1.1.5
The initial modulation attempted when the modems began negotiation.
Status: current Access: read-only
OBJECT-TYPE    
  CctmModulation  

cctmActiveInitialModulation 1.3.6.1.4.1.9.9.165.1.1.1.1.6
The initial negotiated modulation.
Status: current Access: read-only
OBJECT-TYPE    
  CctmModulation  

cctmActiveModulation 1.3.6.1.4.1.9.9.165.1.1.1.1.7
The current modulation for this call. It is possible for retrains to result in the modulation being renogiated during a call. The value of this object will be the same as reported in cmModulationSchemeUsed from CISCO-MODEM-MGMT-MIB while the call is active.
Status: current Access: read-only
OBJECT-TYPE    
  CctmModulation  

cctmActiveAttemptedECProtocol 1.3.6.1.4.1.9.9.165.1.1.1.1.8
The initial modem error correction protocol attempted during call negotiation. The actual EC negotiated is in cctmActiveECProtocol.
Status: current Access: read-only
OBJECT-TYPE    
  CctmECProtocol  

cctmActiveECProtocol 1.3.6.1.4.1.9.9.165.1.1.1.1.9
The modem error correction protocol negotiated for this call. The value of this object will be the same as reported in cmProtocolUsed from CISCO-MODEM-MGMT-MIB while the call is active.
Status: current Access: read-only
OBJECT-TYPE    
  CctmECProtocol  

cctmActiveSupportedDC 1.3.6.1.4.1.9.9.165.1.1.1.1.10
The data compression protocols supported by the calling modem. This object is a bit map, with each bit representing a different call type as identified below. A 1-bit indicates the DC protocol is supported. A 0-bit indicates the DC protocol is not supported. Bit 0 - MNP5 Bit 1 - V.42bis in the receive direction Bit 2 - V.42bis in the transmit direction V.42bis may be separately available in Rx or Tx directions. If all bits are zero, no data compression is supported. The particular compression selected by the answering modem is reported in cctmActiveDataCompression.
Status: current Access: read-only
OBJECT-TYPE    
  BITS mnp5(0), v42bisRx(1), v42bisTx(2), v44Rx(3), v44Tx(4)  

cctmActiveDataCompression 1.3.6.1.4.1.9.9.165.1.1.1.1.11
The modem compression protocol selected for this call.
Status: current Access: read-only
OBJECT-TYPE    
  CctmDataCompression  

cctmActiveRxHighWatermark 1.3.6.1.4.1.9.9.165.1.1.1.1.12
The maximum receive data rate achieved during this call.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

cctmActiveRxLowWatermark 1.3.6.1.4.1.9.9.165.1.1.1.1.13
The minimum receive data rate during this call.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

cctmActiveTxHighWatermark 1.3.6.1.4.1.9.9.165.1.1.1.1.14
The maximum transmit data rate achieved during this call.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

cctmActiveTxLowWatermark 1.3.6.1.4.1.9.9.165.1.1.1.1.15
The minimum transmit data rate during this call.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

cctmActiveLocalUpRateShifts 1.3.6.1.4.1.9.9.165.1.1.1.1.16
The count of locally initiated rate shifts to increase the data rate which were successful.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cctmActiveLocalDownRateShifts 1.3.6.1.4.1.9.9.165.1.1.1.1.17
The count of locally initiated rate shifts to decrease the data rate which were successful.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cctmActiveRemoteUpRateShifts 1.3.6.1.4.1.9.9.165.1.1.1.1.18
The count of remotely initiated rate shifts to increase the data rate which were successful.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cctmActiveRemoteDownRateShifts 1.3.6.1.4.1.9.9.165.1.1.1.1.19
The count of remotely initiated rate shifts to decrease the data rate which were successful.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cctmActiveRateShiftFailures 1.3.6.1.4.1.9.9.165.1.1.1.1.20
The count of rate shift attempts which failed to complete. A failure to complete a rate renegotiation results in a retrain attempt.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cctmActiveLocalRetrains 1.3.6.1.4.1.9.9.165.1.1.1.1.21
The count of locally initiated retrains for the call. Includes successfully completed retrains and those which failed.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cctmActiveRemoteRetrains 1.3.6.1.4.1.9.9.165.1.1.1.1.22
The count of remotely initiated retrains for the call. Includes successfully completed retrains and those which failed.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cctmActiveRetrainFailures 1.3.6.1.4.1.9.9.165.1.1.1.1.23
The count of retrains which failed to complete. A failure to retrain results in another retrain attempt. The call will terminate if too many consecutive retrain failures occur. The consecutive retrain failure threshold is system specific.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cctmActiveRxLinkOctets 1.3.6.1.4.1.9.9.165.1.1.1.1.24
The total modem link level octets received during this call. If using Error Correction and Data Compression, this is the compressed data within the EC protocol frames.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cctmActiveTxLinkOctets 1.3.6.1.4.1.9.9.165.1.1.1.1.25
The total modem link level octets transmitted during this call. If using Error Correction and Data Compression, this is the compressed data within the EC protocol frames.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cctmActiveRxECFrames 1.3.6.1.4.1.9.9.165.1.1.1.1.26
The total number of error correction data frames received successfully. This does not include damaged frames or control frames.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cctmActiveTxECFrames 1.3.6.1.4.1.9.9.165.1.1.1.1.27
The total number of error correction data frames transmitted successfully. This does not include data frame resends or control frames.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cctmActiveRxECNAKs 1.3.6.1.4.1.9.9.165.1.1.1.1.28
The total number of EC protocol negative acknowledgements (NAK) received.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cctmActiveTxECNAKs 1.3.6.1.4.1.9.9.165.1.1.1.1.29
The total number of EC protocol negative acknowledgements (NAK) sent.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cctmActiveRxECFramesBad 1.3.6.1.4.1.9.9.165.1.1.1.1.30
The total error correction frames received during the call which were determined to be bad.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cctmActiveECFramesResent 1.3.6.1.4.1.9.9.165.1.1.1.1.31
The count of total retransmitted error correction data frames during the call.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cctmActiveECLinkTimeouts 1.3.6.1.4.1.9.9.165.1.1.1.1.32
This counter provides the number of EC link protocol timer expirations which have occurred during the call. This corresponds to the T401 timer for LAPM and MNP. These are distinct from normal 'keep alive' and 'window open' timeouts.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cctmActiveRxCharLost 1.3.6.1.4.1.9.9.165.1.1.1.1.33
The number of characters received by the modem but were dropped due to host buffer over run.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cctmHistoryTable 1.3.6.1.4.1.9.9.165.1.2.1
This table provides information on terminated modem calls. It contains general modem session attributes and statistics at the modem link and modem protocol layers. The table extends the cctHistoryTable, using the same index, cctHistoryIndex. There are no entries for calls not requiring modem services.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CctmHistoryEntry

cctmHistoryEntry 1.3.6.1.4.1.9.9.165.1.2.1.1
The information regarding a single terminated modem call. Entries are created and deleted in sync with the entries in cctHistoryTable, if the call utilized modem service.
Status: current Access: not-accessible
OBJECT-TYPE    
  CctmHistoryEntry  

cctmHistoryProjectedMaxRxRate 1.3.6.1.4.1.9.9.165.1.2.1.1.1
Maximum received rate local modem informs remote modem it will support based on initial negotiations. The remote modem will not attempt to transmit at rates greater than what the local modem will accept. The initial negotiated receive rate is in cctHistoryRxRate.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

cctmHistoryProjectedMaxTxRate 1.3.6.1.4.1.9.9.165.1.2.1.1.2
Maximum rate the remote modem indicates it can accept based on initial negotiations. The local modem will not attempt to transmit at rates above what the remote modem will accept. The initial negotiated transmit rate is in cctHistoryTxRate.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

cctmHistoryFinalRxRate 1.3.6.1.4.1.9.9.165.1.2.1.1.3
Final receive data rate for this call. The initial negotiated receive rate is in cctHistoryRxRate.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

cctmHistoryFinalTxRate 1.3.6.1.4.1.9.9.165.1.2.1.1.4
Final transmit data rate for this call. The initial negotiated transmit rate is in cctHistoryTxRate.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

cctmHistoryAttemptedModulation 1.3.6.1.4.1.9.9.165.1.2.1.1.5
The initial modulation attempted when the modems began negotiation.
Status: current Access: read-only
OBJECT-TYPE    
  CctmModulation  

cctmHistoryInitialModulation 1.3.6.1.4.1.9.9.165.1.2.1.1.6
The initial negotiated modulation.
Status: current Access: read-only
OBJECT-TYPE    
  CctmModulation  

cctmHistoryFinalModulation 1.3.6.1.4.1.9.9.165.1.2.1.1.7
The final modulation for this call. It is possible for retrains to result in the modulation being renogiated during a call.
Status: current Access: read-only
OBJECT-TYPE    
  CctmModulation  

cctmHistoryAttemptedECProtocol 1.3.6.1.4.1.9.9.165.1.2.1.1.8
The initial modem error correction protocol attempted during call negotiation. The actual EC negotiated is in cctmHistoryECProtocol.
Status: current Access: read-only
OBJECT-TYPE    
  CctmECProtocol  

cctmHistoryECProtocol 1.3.6.1.4.1.9.9.165.1.2.1.1.9
The modem error correction protocol negotiated for this call.
Status: current Access: read-only
OBJECT-TYPE    
  CctmECProtocol  

cctmHistorySupportedDC 1.3.6.1.4.1.9.9.165.1.2.1.1.10
The data compression protocols supported by the calling modem. This object is a bit map, with each bit representing a different call type as identified below. A 1-bit indicates the DC protocol is supported. A 0-bit indicates the DC protocol is not supported. Bit 0 - MNP5 Bit 1 - V.42bis in the receive direction Bit 2 - V.42bis in the transmit direction V.42bis may be separately available in Rx or Tx directions. If all bits are zero, no data compression is supported. The particular compression selected by the answering modem is reported in cctmHistoryDataCompression.
Status: current Access: read-only
OBJECT-TYPE    
  BITS mnp5(0), v42bisRx(1), v42bisTx(2), v44Rx(3), v44Tx(4)  

cctmHistoryDataCompression 1.3.6.1.4.1.9.9.165.1.2.1.1.11
The modem compression protocol selected for this call.
Status: current Access: read-only
OBJECT-TYPE    
  CctmDataCompression  

cctmHistoryRxHighWatermark 1.3.6.1.4.1.9.9.165.1.2.1.1.12
The maximum receive data rate achieved during this call.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

cctmHistoryRxLowWatermark 1.3.6.1.4.1.9.9.165.1.2.1.1.13
The minimum receive data rate during this call.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

cctmHistoryTxHighWatermark 1.3.6.1.4.1.9.9.165.1.2.1.1.14
The maximum transmit data rate achieved during this call.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

cctmHistoryTxLowWatermark 1.3.6.1.4.1.9.9.165.1.2.1.1.15
The minimum transmit data rate during this call.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

cctmHistoryLocalUpRateShifts 1.3.6.1.4.1.9.9.165.1.2.1.1.16
The count of locally initiated rate shifts to increase the data rate which were successful.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cctmHistoryLocalDownRateShifts 1.3.6.1.4.1.9.9.165.1.2.1.1.17
The count of locally initiated rate shifts to decrease the data rate which were successful.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cctmHistoryRemoteUpRateShifts 1.3.6.1.4.1.9.9.165.1.2.1.1.18
The count of remotely initiated rate shifts to increase the data rate which were successful.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cctmHistoryRemoteDownRateShifts 1.3.6.1.4.1.9.9.165.1.2.1.1.19
The count of remotely initiated rate shifts to decrease the data rate which were successful.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cctmHistoryRateShiftFailures 1.3.6.1.4.1.9.9.165.1.2.1.1.20
The count of rate shift attempts which failed to complete. A failure to complete a rate renegotiation results in a retrain attempt.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cctmHistoryLocalRetrains 1.3.6.1.4.1.9.9.165.1.2.1.1.21
The count of locally initiated retrains for the call. Includes successfully completed retrains and those which failed.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cctmHistoryRemoteRetrains 1.3.6.1.4.1.9.9.165.1.2.1.1.22
The count of remotely initiated retrains for the call. Includes successfully completed retrains and those which failed.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cctmHistoryRetrainFailures 1.3.6.1.4.1.9.9.165.1.2.1.1.23
The count of retrains which failed to complete. A failure to retrain results in another retrain attempt. The call will terminate if too many consecutive retrain failures occur. The consecutive retrain failure threshold is system specific.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cctmHistoryRxLinkOctets 1.3.6.1.4.1.9.9.165.1.2.1.1.24
The total modem link level octets received during this call. If using Error Correction and Data Compression, this is the compressed data within the EC protocol frames.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cctmHistoryTxLinkOctets 1.3.6.1.4.1.9.9.165.1.2.1.1.25
The total modem link level octets transmitted during this call. If using Error Correction and Data Compression, this is the compressed data within the EC protocol frames.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cctmHistoryRxECFrames 1.3.6.1.4.1.9.9.165.1.2.1.1.26
The total number of error correction data frames received successfully. This does not include damaged frames or control frames.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cctmHistoryTxECFrames 1.3.6.1.4.1.9.9.165.1.2.1.1.27
The total number of error correction data frames transmitted successfully. This does not include data frame resends or control frames.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cctmHistoryRxECNAKs 1.3.6.1.4.1.9.9.165.1.2.1.1.28
The total number of EC protocol negative acknowledgements (NAK) received.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cctmHistoryTxECNAKs 1.3.6.1.4.1.9.9.165.1.2.1.1.29
The total number of EC protocol negative acknowledgements (NAK) sent.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cctmHistoryRxECFramesBad 1.3.6.1.4.1.9.9.165.1.2.1.1.30
The total error correction frames received during the call which were determined to be bad.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cctmHistoryECFramesResent 1.3.6.1.4.1.9.9.165.1.2.1.1.31
The count of total retransmitted error correction data frames during the call.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cctmHistoryECLinkTimeouts 1.3.6.1.4.1.9.9.165.1.2.1.1.32
This counter provides the number of EC link protocol timer expirations which have occurred during the call. This corresponds to the T401 timer for LAPM and MNP. These are distinct from normal 'keep alive' and 'window open' timeouts.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cctmHistoryRxCharLost 1.3.6.1.4.1.9.9.165.1.2.1.1.33
The total number of characters received by the modem but were dropped due to host buffer over run.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cctmHistoryDisconnectReason 1.3.6.1.4.1.9.9.165.1.2.1.1.34
Code indicating the reason this call was terminated.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

cctmHistoryDisconnectReasonText 1.3.6.1.4.1.9.9.165.1.2.1.1.35
Text description of the disconnect reason indicated by cctHistoryDisconnectReason. Value is zero-length string if no text is available.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cctmXHistoryTable 1.3.6.1.4.1.9.9.165.1.2.2
This table provides additional, detailed information on terminated modem calls. It contains low level modem session attributes and statistics at the modem link and modem protocol layers. The table extends the cctHistoryTable, using the same index, cctHistoryIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CctmXHistoryEntry

cctmXHistoryEntry 1.3.6.1.4.1.9.9.165.1.2.2.1
The detailed information for a single terminated modem call. Entries are created and deleted in sync with the entries in cctHistoryTable, if the call utilized modem service.
Status: current Access: not-accessible
OBJECT-TYPE    
  CctmXHistoryEntry  

cctmXHistoryRxECInfoFrameSize 1.3.6.1.4.1.9.9.165.1.2.2.1.1
Negotiated maximum EC frame data payload size in the receive direction. LAPM distinguishes between Rx and Tx. MNP will have the the same information frame size for Rx and Tx, cctmHistoryTxECInfoFrameSize.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

cctmXHistoryTxECInfoFrameSize 1.3.6.1.4.1.9.9.165.1.2.2.1.2
Negotiated maximum EC frame data payload size in the transmit direction. LAPM distinguishes between Rx and Tx. MNP will have the the same information frame size for Tx and Rx, cctmHistoryRxECInfoFrameSize.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

cctmXHistoryRxECWindowSize 1.3.6.1.4.1.9.9.165.1.2.2.1.3
The EC protocol window size in units of frames in the receive direction. This is the maximum number of information frames sent from remote modem that may be outstanding without receiving any acknowledgement from the local modem. If the EC protocol is LAPM, the Rx and Tx windows are separately negotiated and may have different values. If MNP, both windows are negotiated together and have the same value for this object and cctHistoryTxECWindowSize.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

cctmXHistoryTxECWindowSize 1.3.6.1.4.1.9.9.165.1.2.2.1.4
The EC protocol window size in units of frames in the transmit direction. This is the maximum number of information frames sent from local modem that may be outstanding without receiving any acknowledgement from the remote modem. If the EC protocol is LAPM, the Rx and Tx windows are separately negotiated and may have different values. If MNP, both windows are negotiated together and have the same value for this object and cctHistoryRxECWindowSize.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

cctmXHistoryRxLevel 1.3.6.1.4.1.9.9.165.1.2.2.1.5
The final signal level in the receive direction for applicable modulations.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -128..0  

cctmXHistoryTxLevel 1.3.6.1.4.1.9.9.165.1.2.2.1.6
The final signal level in the transmit direction for applicable modulations.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -128..0  

cctmXHistoryConstellation 1.3.6.1.4.1.9.9.165.1.2.2.1.7
Connection constellation size.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER points4(1), points16(2)  

cctmXHistoryV90Status 1.3.6.1.4.1.9.9.165.1.2.2.1.8
This object indicates if V.90 modulation was attempted during initial modem negotiation. notAttempted(1) - Client modem did not attempt V.90 failure(2) - Client and server modems attempted V.90, but were not successful success(3) - Client and server modems successfully negotiated V.90 during call setup.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notAttempted(1), failure(2), success(3)  

cctmXHistoryV90Failure 1.3.6.1.4.1.9.9.165.1.2.2.1.9
This object provides an interpretation of why V.90 modulation was not achieved. noFailure(1) - V.90 was not attempted or it was successful. The value of cctmXHistoryV90Status will be notAttempted(1) or success(3) respectively. clientNonPCM(2) - Client selected a non-PCM connection due to PSTN properties. clientFallback(3) - Client was unable to sustain PCM due to PSTN properties and fellback to a non-PCM connection. serverV90Disabled(4) - Client attempted V.90 but server modem was configured to disable V.90.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noFailure(1), clientNonPCM(2), clientFallback(3), serverV90Disabled(4)  

cctmXHistoryV90ClientId 1.3.6.1.4.1.9.9.165.1.2.2.1.10
Client modem identification inferred from the V.90 DIL training and sign patterns.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..255  

cctmXHistoryECWindowClosures 1.3.6.1.4.1.9.9.165.1.2.2.1.11
The number of times the EC protocol window closed without receiving an ACK or NAK from the remote modem. A closure occurs when the maximum number of EC information frames have been sent without receiving any acknowledgement. The window size is provided in cctmHistoryRxECWindowSize.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cctmMIBNotificationPrefix 1.3.6.1.4.1.9.9.165.2
OBJECT IDENTIFIER    

cctmMIBNotifications 1.3.6.1.4.1.9.9.165.2.0
OBJECT IDENTIFIER    

cctmMIBConformance 1.3.6.1.4.1.9.9.165.3
OBJECT IDENTIFIER    

cctmMIBCompliances 1.3.6.1.4.1.9.9.165.3.1
OBJECT IDENTIFIER    

cctmMIBGroups 1.3.6.1.4.1.9.9.165.3.2
OBJECT IDENTIFIER    

cctmMIBCompliance 1.3.6.1.4.1.9.9.165.3.1.1
The compliance statement for entities which implement the CISCO CALL TRACKER MODEM MIB
Status: current Access: read-only
MODULE-COMPLIANCE    

cctmActiveGroup 1.3.6.1.4.1.9.9.165.3.2.2
A collection of objects providing the active call modem information.
Status: current Access: read-only
OBJECT-GROUP    

cctmHistoryGroup 1.3.6.1.4.1.9.9.165.3.2.3
A collection of objects providing the historical call modem information.
Status: current Access: read-only
OBJECT-GROUP    

cctmXHistoryGroup 1.3.6.1.4.1.9.9.165.3.2.4
A collection of objects providing the historical detailed call modem information.
Status: current Access: read-only
OBJECT-GROUP