CISCO-CIRCUIT-INTERFACE-MIB

File: CISCO-CIRCUIT-INTERFACE-MIB.mib (5760 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
SNMP-FRAMEWORK-MIB IF-MIB CISCO-SMI

Imported symbols

MODULE-IDENTITY OBJECT-TYPE RowStatus
MODULE-COMPLIANCE OBJECT-GROUP SnmpAdminString
ifIndex ciscoMgmt

Defined Types

CciDescriptionEntry  
SEQUENCE    
  cciDescr SnmpAdminString
  cciStatus RowStatus

Defined Values

ciscoCircuitInterfaceMIB 1.3.6.1.4.1.9.9.160
The MIB module to configure the circuit description for an interface. The circuit description can be used to describe and identify circuits on interfaces like ATM, frame-relay etc.
MODULE-IDENTITY    

ciscoCircuitInterfaceMIBObjects 1.3.6.1.4.1.9.9.160.1
OBJECT IDENTIFIER    

cciDescription 1.3.6.1.4.1.9.9.160.1.1
OBJECT IDENTIFIER    

cciDescriptionTable 1.3.6.1.4.1.9.9.160.1.1.1
This table contains a circuit description to identify circuit based interfaces like ATM, Frame-Relay etc. The circuit description could be used for example, to correlate performance statistics associated with the corresponding interfaces.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CciDescriptionEntry

cciDescriptionEntry 1.3.6.1.4.1.9.9.160.1.1.1.1
Each cciDescriptionEntry contains the circuit description for a particular circuit based interface. The entry is identified by the ifIndex which would typically correspond to circuit based interfaces. Interfaces with ifType equal to atm(37), frameRelay(32) frameRelayService(44) are some examples. Entries can only be created by management station action. Entries can be deleted by setting the cciStatus object to destroy(6). The agent will delete any cciEntry if the corresponding ifEntry is deleted. Entries are not maintained in any kind of NV-storage, and will not be recreated by the agent after a reboot.
Status: current Access: not-accessible
OBJECT-TYPE    
  CciDescriptionEntry  

cciDescr 1.3.6.1.4.1.9.9.160.1.1.1.1.1
The circuit description of the interface. It has no default value.
Status: current Access: read-create
OBJECT-TYPE    
  SnmpAdminString Size(0..255)  

cciStatus 1.3.6.1.4.1.9.9.160.1.1.1.1.2
The row status object, but with restricted values. Only two values are allowed for this object: createAndGo(4) and destroy(6). The row is created by specifying the value for cciDescr and setting this object to createAndGo(4). If the row creation is succesfull, the cciStatus would be active(1). In the active(1) state, the cciDescr can be modifed. The row is deleted by setting this object to destroy(6).
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

ciscoCircuitInterfaceMIBConformance 1.3.6.1.4.1.9.9.160.3
OBJECT IDENTIFIER    

ciscoCircuitInterfaceMIBCompliances 1.3.6.1.4.1.9.9.160.3.1
OBJECT IDENTIFIER    

ciscoCircuitInterfaceMIBGroups 1.3.6.1.4.1.9.9.160.3.2
OBJECT IDENTIFIER    

ciscoCircuitInterfaceMIBCompliance 1.3.6.1.4.1.9.9.160.3.1.1
The compliance statement for Cisco agents which implement the Cisco Circuit Interface MIB.
Status: current Access: read-create
MODULE-COMPLIANCE    

ciscoCircuitInterfaceGroup 1.3.6.1.4.1.9.9.160.3.2.1
The Cisco Circuit Interface MIB objects.
Status: current Access: read-create
OBJECT-GROUP