CISCO-VISM-SVC-MIB

File: CISCO-VISM-SVC-MIB.mib (17813 bytes)

Imported modules

SNMPv2-SMI SNMPv2-CONF BASIS-MIB
CISCOWAN-SMI

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Integer32
Counter32 MODULE-COMPLIANCE OBJECT-GROUP
voice ciscoWan

Defined Values

ciscoVismSvcMIB 1.3.6.1.4.1.351.150.90
The MIB module containing SVC information for VISM service module.
MODULE-IDENTITY    

vismSvcGrp 1.3.6.1.4.1.351.110.5.5.10
OBJECT IDENTIFIER    

vismSvcCnfGroups 1.3.6.1.4.1.351.110.5.5.19
OBJECT IDENTIFIER    

vismSvcAtmQosGrp 1.3.6.1.4.1.351.110.5.5.19.1
OBJECT IDENTIFIER    

vismSvcTrfScalingGrp 1.3.6.1.4.1.351.110.5.5.19.2
OBJECT IDENTIFIER    

vismSvcAal2CidGrp 1.3.6.1.4.1.351.110.5.5.19.3
OBJECT IDENTIFIER    

vismSvcTxSetups 1.3.6.1.4.1.351.110.5.5.10.1
This is the number of Setup messages sent to the PXM(Processor Switch Module) from the VISM since VISM reset.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

vismSvcRxSetups 1.3.6.1.4.1.351.110.5.5.10.2
This is the number of Setup messages received by the VISM from the PXM since VISM reset.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

vismSvcTxCallProcs 1.3.6.1.4.1.351.110.5.5.10.3
This is the number of Call proceeding messages sent to the PXM from the VISM since VISM reset.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

vismSvcRxCallProcs 1.3.6.1.4.1.351.110.5.5.10.4
This is the number of Call proceeding messages received by the VISM from the PXM since VISM reset.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

vismSvcTxConns 1.3.6.1.4.1.351.110.5.5.10.5
This is the number of Connect messages sent to the PXM from the VISM since VISM reset.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

vismSvcTxConnAcks 1.3.6.1.4.1.351.110.5.5.10.6
This is the number of Connect ack messages sent to the PXM from the VISM since VISM reset.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

vismSvcRxConns 1.3.6.1.4.1.351.110.5.5.10.7
This is the number of Connect messages received by the VISM from the PXM since VISM reset.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

vismSvcRxConnAcks 1.3.6.1.4.1.351.110.5.5.10.8
This is the number of Connect ack messages received by the VISM from the PXM since VISM reset.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

vismSvcTxReleases 1.3.6.1.4.1.351.110.5.5.10.9
This is the number of Release messages sent to the PXM from the VISM since VISM reset.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

vismSvcTxReleaseCompls 1.3.6.1.4.1.351.110.5.5.10.10
This is the number of Release complete messages sent to the PXM from the VISM since VISM reset.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

vismSvcRxReleases 1.3.6.1.4.1.351.110.5.5.10.11
This is the number of Release messages received by the VISM from the PXM since VISM reset.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

vismSvcRxReleaseCompls 1.3.6.1.4.1.351.110.5.5.10.12
This is the number of Release complete messages received by the VISM from the PXM since VISM reset.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

vismSvcTxRestarts 1.3.6.1.4.1.351.110.5.5.10.13
This is the number of Restart messages sent to the PXM from the VISM since VISM reset.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

vismSvcTxRestartAcks 1.3.6.1.4.1.351.110.5.5.10.14
This is the number of Restart ack messages sent to the PXM from the VISM since VISM reset.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

vismSvcRxRestarts 1.3.6.1.4.1.351.110.5.5.10.15
This is the number of Restart messages received by the VISM from the PXM since VISM reset.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

vismSvcRxRestartAcks 1.3.6.1.4.1.351.110.5.5.10.16
This is the number of Restart ack messages received by the VISM from the PXM since VISM reset.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

vismSvcTxResyncStrts 1.3.6.1.4.1.351.110.5.5.10.17
This is the number of Resync start messages sent to the PXM from the VISM since VISM reset.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

vismSvcTxResyncStrtAcks 1.3.6.1.4.1.351.110.5.5.10.18
This is the number of Resync start ack messages sent to the PXM from the VISM since VISM reset.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

vismSvcRxResyncStrts 1.3.6.1.4.1.351.110.5.5.10.19
This is the number of Resync start messages received by the VISM from the PXM since VISM reset.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

vismSvcRxResyncStrtAcks 1.3.6.1.4.1.351.110.5.5.10.20
This is the number of Resync start ack messages received by the VISM from the PXM since VISM reset.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

vismSvcTxResyncEnds 1.3.6.1.4.1.351.110.5.5.10.21
This is the number of Resync end messages sent to the PXM from the VISM since VISM reset.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

vismSvcTxResyncEndAcks 1.3.6.1.4.1.351.110.5.5.10.22
This is the number of Resync end ack messages sent to the PXM from the VISM since VISM reset.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

vismSvcRxResyncEnds 1.3.6.1.4.1.351.110.5.5.10.23
This is the number of Resync end messages received by the VISM from the PXM since VISM reset.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

vismSvcRxResyncEndAcks 1.3.6.1.4.1.351.110.5.5.10.24
This is the number of Resync end ack messages received by the VISM from the PXM since VISM reset.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

vismSvcTxBulkResyncs 1.3.6.1.4.1.351.110.5.5.10.25
This is the number of Bulk resync messages sent to the PXM from the VISM since VISM reset.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

vismSvcRxBulkResyncs 1.3.6.1.4.1.351.110.5.5.10.26
This is the number of Bulk resync messages received by the VISM from the PXM since VISM reset.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

vismSvcCallProcExpiries 1.3.6.1.4.1.351.110.5.5.10.27
This object indicates the number of times the call proceeding timer expired before a connect message is received.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

vismSvcReleasExpiries 1.3.6.1.4.1.351.110.5.5.10.28
This object indicates the number of times the release timer expired before a release complete message is received.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

vismSvcConnExpiries 1.3.6.1.4.1.351.110.5.5.10.29
This object indicates the number of times the connect timer expired before a connection message is received.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

vismSvcConnAckExpiries 1.3.6.1.4.1.351.110.5.5.10.30
This object indicates the number of times the connect ack timer expires before a connect ack message is received.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

vismSvcRestartExpiries 1.3.6.1.4.1.351.110.5.5.10.31
This object indicate the number of times the restart timer expires before a Restart Response message is received.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

vismSvcResyncExpiries 1.3.6.1.4.1.351.110.5.5.10.32
This object indicate the number of times the Resync timer expired a Resync End Indication message is received.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

vismSvcAtmQosCdv 1.3.6.1.4.1.351.110.5.5.19.1.1
End-to-end cell delay variation used in voice SVC establishment. It is used to guarantee the quality of the route selected for a voice SVC. It is applicable to both AAL1 and AAL2 SVC connection establishment. The value specified to this object is in 'micro-seconds'. This value is sent in voice SVC setup messages in extended quality of services information element as the objective value.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 500..20000  

vismSvcAtmQosCtd 1.3.6.1.4.1.351.110.5.5.19.1.2
End-to-end maximum cell transfer delay used in voice SVC establishment. It is used to guarantee the quality of the route selected for a voice SVC. It is applicable to both AAL1 and AAL2 SVC connection establishment. The value specified to this object is in 'micro-seconds'. This value is sent in voice SVC setup messages in end-to-end transit delay information element as the objective value.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 20000..150000  

vismSvcAtmQosClr 1.3.6.1.4.1.351.110.5.5.19.1.3
Maximum Cell Loss Ratio used in voice SVC establishment. It is used to guarantee the quality of the route selected for a voice SVC. It is applicable to both AAL1 and AAL2 SVC connection establishment. This value is sent in voice SVC setup messages in extended quality of services information element as maximum cell loss ratio value.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 4..8  

vismSvcTrfScalingFactor 1.3.6.1.4.1.351.110.5.5.19.2.1
Traffic scaling Factor used to compute factored bandwidth which is used in ATM signaling to establish voice SVC. When this value is less than 100 it can be referred as a `discount factor' and when more than 100 referred as an `excess factor' It is applicable only to VBR SVC connection establishment. The traffic scaling is not applicable to AAL2 SVC calls that require G.711 and clear channel codecs
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 50..200  

vismSvcAal2CidNumber 1.3.6.1.4.1.351.110.5.5.19.3.1
The default AAL2 Channel IDentification (CID) number used for AAL2 SVC connections.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 8..255  

ciscoVismSvcMIBConformance 1.3.6.1.4.1.351.150.90.2
OBJECT IDENTIFIER    

ciscoVismSvcMIBGroups 1.3.6.1.4.1.351.150.90.2.1
OBJECT IDENTIFIER    

ciscoVismSvcMIBCompliances 1.3.6.1.4.1.351.150.90.2.2
OBJECT IDENTIFIER    

ciscoVismSvcCompliance 1.3.6.1.4.1.351.150.90.2.2.1
The compliance statement for objects related to VISM SVC module.
Status: current Access: read-write
MODULE-COMPLIANCE    

ciscoVismSvcCounterGroup 1.3.6.1.4.1.351.150.90.2.1.1
The collection of objects which are used to represent VISM SVC counters.
Status: current Access: read-write
OBJECT-GROUP    

ciscoVismSvcAtmQosGroup 1.3.6.1.4.1.351.150.90.2.1.2
The collection of objects which are used to represent VISM SVC Signaling and QOS parameters.
Status: current Access: read-write
OBJECT-GROUP    

ciscoVismSvcTrfScalingGrp 1.3.6.1.4.1.351.150.90.2.1.3
This object is are used to represent VISM scaling factor to SVC Signaling traffic parameter.
Status: current Access: read-write
OBJECT-GROUP    

ciscoVismSvcAal2CidGrp 1.3.6.1.4.1.351.150.90.2.1.4
This object is used to represent VISM SVC AAL2 Cid.
Status: current Access: read-write
OBJECT-GROUP