CISCOSB-STACK-MIB

File: CISCOSB-STACK-MIB.mib (9458 bytes)

Imported modules

BRIDGE-MIB CISCOSB-MIB SNMPv2-SMI
SNMPv2-TC

Imported symbols

MacAddress switch001 OBJECT-TYPE
MODULE-IDENTITY TruthValue TEXTUAL-CONVENTION

Defined Types

StackMode  
INTEGER standalone(1), native(2), basic-hybrid(3), advanced-hybrid(4), advanced-hybrid-XG(5)    

PortsPair  
INTEGER pair-s1s2(1), pair-s3s4(2), pair-s1s25G(3), pair-s1s2Xg(4), pair-lionXg(5)    

HybridStackPortSpeed  
INTEGER port-speed-1G(1), port-speed-5G(2), port-speed-10G(3), port-speed-auto(4), port-speed-down(5)    

HybridStackDeviceMode  
INTEGER mode-L2(1), mode-L3(2)    

RlStackActiveUnitIdEntry  
SEQUENCE    
  rlStackCurrentUnitId INTEGER
  rlStackActiveUnitIdAfterReset INTEGER

RlStackHybridEntry  
SEQUENCE    
  rlStackHybridUnitId INTEGER
  rlStackHybridStackMode StackMode
  rlStackHybridPortsPair PortsPair
  rlStackHybridPortNo1speed HybridStackPortSpeed
  rlStackHybridPortNo2speed HybridStackPortSpeed
  rlStackHybridUnitIdAfterReset INTEGER
  rlStackHybridStackModeAfterReset StackMode
  rlStackHybridPortsPairAfterReset PortsPair
  rlStackHybridPortNo1speedAfterReset HybridStackPortSpeed
  rlStackHybridPortNo2speedAfterReset HybridStackPortSpeed
  rlStackHybridDeleteStartupAfterReset TruthValue
  rlStackHybridDeviceModeAfterReset HybridStackDeviceMode
  rlStackHybridXgPortNo1Num INTEGER
  rlStackHybridXgPortNo1NumAfterReset INTEGER
  rlStackHybridXgPortNo2Num INTEGER
  rlStackHybridXgPortNo2NumAfterReset INTEGER

Defined Values

rlStack 1.3.6.1.4.1.9.6.1.101.107
The private MIB module definition for stack.
MODULE-IDENTITY    

rlStackActiveUnitIdTable 1.3.6.1.4.1.9.6.1.101.107.1
The table listing the active unit id of the requested unit.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RlStackActiveUnitIdEntry

rlStackActiveUnitIdEntry 1.3.6.1.4.1.9.6.1.101.107.1.1
An entry in the rlStackActiveUnitIdTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  RlStackActiveUnitIdEntry  

rlStackCurrentUnitId 1.3.6.1.4.1.9.6.1.101.107.1.1.1
The unit number device, which is the active unit id
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER  

rlStackActiveUnitIdAfterReset 1.3.6.1.4.1.9.6.1.101.107.1.1.2
Indicates the unit id that will be after reset.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

rlStackUnitModeAfterReset 1.3.6.1.4.1.9.6.1.101.107.2
set unit type that will be after reset, standalone or stack.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER standalone(1), stack(2)  

rlStackUnitMode 1.3.6.1.4.1.9.6.1.101.107.3
show unit type standalone or stack.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER standalone(1), stack(2)  

rlStackUnitMacAddressAfterReset 1.3.6.1.4.1.9.6.1.101.107.4
The MAC address used by this bridge after rest.
Status: current Access: read-write
OBJECT-TYPE    
  MacAddress  

rlStackHybridTable 1.3.6.1.4.1.9.6.1.101.107.5
The table listing information required for hybrid stack.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RlStackHybridEntry

rlStackHybridEntry 1.3.6.1.4.1.9.6.1.101.107.5.1
An entry in the rlStackActiveUnitIdTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  RlStackHybridEntry  

rlStackHybridUnitId 1.3.6.1.4.1.9.6.1.101.107.5.1.1
The unit number device, which is the active unit id
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..8  

rlStackHybridStackMode 1.3.6.1.4.1.9.6.1.101.107.5.1.2
Indicates the unit stack mode.
Status: current Access: read-only
OBJECT-TYPE    
  StackMode  

rlStackHybridPortsPair 1.3.6.1.4.1.9.6.1.101.107.5.1.3
Indicates the PortsPair.
Status: current Access: read-only
OBJECT-TYPE    
  PortsPair  

rlStackHybridPortNo1speed 1.3.6.1.4.1.9.6.1.101.107.5.1.4
Indicates the rlStackHybridPortNo1speed.
Status: current Access: read-only
OBJECT-TYPE    
  HybridStackPortSpeed  

rlStackHybridPortNo2speed 1.3.6.1.4.1.9.6.1.101.107.5.1.5
Indicates the rlStackHybridPortNo2speed.
Status: current Access: read-only
OBJECT-TYPE    
  HybridStackPortSpeed  

rlStackHybridUnitIdAfterReset 1.3.6.1.4.1.9.6.1.101.107.5.1.6
Indicates the unit id that will be after reset.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..8  

rlStackHybridStackModeAfterReset 1.3.6.1.4.1.9.6.1.101.107.5.1.7
Indicates the unit stack mode that will be after reset.
Status: current Access: read-write
OBJECT-TYPE    
  StackMode  

rlStackHybridPortsPairAfterReset 1.3.6.1.4.1.9.6.1.101.107.5.1.8
Indicates the PortsPair that will be after reset.
Status: current Access: read-write
OBJECT-TYPE    
  PortsPair  

rlStackHybridPortNo1speedAfterReset 1.3.6.1.4.1.9.6.1.101.107.5.1.9
Indicates the HybridStackPortSpeed that will be after reset.
Status: current Access: read-write
OBJECT-TYPE    
  HybridStackPortSpeed  

rlStackHybridPortNo2speedAfterReset 1.3.6.1.4.1.9.6.1.101.107.5.1.10
Indicates the HybridStackPortSpeed that will be after reset.
Status: current Access: read-write
OBJECT-TYPE    
  HybridStackPortSpeed  

rlStackHybridDeleteStartupAfterReset 1.3.6.1.4.1.9.6.1.101.107.5.1.11
Indicates whether the startup configuration is deleted after reset.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

rlStackHybridDeviceModeAfterReset 1.3.6.1.4.1.9.6.1.101.107.5.1.12
Indicates Device mode (Layer2 or Layer3) after reset.
Status: current Access: read-write
OBJECT-TYPE    
  HybridStackDeviceMode  

rlStackHybridXgPortNo1Num 1.3.6.1.4.1.9.6.1.101.107.5.1.13
Indicates the 1st stack cascade active port number.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..16  

rlStackHybridXgPortNo1NumAfterReset 1.3.6.1.4.1.9.6.1.101.107.5.1.14
Indicates the 1st stack cascade port number that will be after reset.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..16  

rlStackHybridXgPortNo2Num 1.3.6.1.4.1.9.6.1.101.107.5.1.15
Indicates the 2nd stack cascade active port number.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..16  

rlStackHybridXgPortNo2NumAfterReset 1.3.6.1.4.1.9.6.1.101.107.5.1.16
Indicates the 2nd stack cascade port number that will be after reset.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..16