CTRON-SSR-TRAP-MIB
File:
CTRON-SSR-TRAP-MIB.mib (11919 bytes)
Imported modules
Imported symbols
Defined Values
ssrTrapsMIB |
1.3.6.1.4.1.52.2501.1.300 |
This module describes the traps specific to the Smart Switch Router. |
MODULE-IDENTITY |
|
|
|
envPowerSupplyFailed |
1.3.6.1.4.1.52.2501.10.2.1 |
A power supply on the sending device has failed. The
sysHwPowerSupply object identifies the failed supply. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
envPowerSupplyRecovered |
1.3.6.1.4.1.52.2501.10.2.2 |
A power supply on the sending device has recovered
after failure. The sysHwPowerSupply object identifies
the recovered supply. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
envFanFailed |
1.3.6.1.4.1.52.2501.10.2.3 |
A Fan tray on the sending device has failed. The
sysHwFan object identifies the failed fan tray. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
envFanRecovered |
1.3.6.1.4.1.52.2501.10.2.4 |
A Fan tray on the sending device has recovered
after failure. The sysHwFan object identifies
the recovered Fan tray. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
envTempExceeded |
1.3.6.1.4.1.52.2501.10.2.5 |
A temperature inside the chassis on the sending device has exceeded
normal operating temperature. The sysHwTemperature object
identifies the current status. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
envTempNormal |
1.3.6.1.4.1.52.2501.10.2.6 |
A temperature inside the chassis on the sending device has returned
to normal operating temperature. The sysHwTemperature
object identifies the current status. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
envHotSwapIn |
1.3.6.1.4.1.52.2501.10.2.7 |
A module has been inserted into the chassis.
sysHwModuleSlotNumber identifies the slot the module was inserted into. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
envHotSwapOut |
1.3.6.1.4.1.52.2501.10.2.8 |
A module has been turned off or removed from the chassis.
sysHwModuleSlotNumber identifies the slot the module was removed from. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
envBackupControlModuleOnline |
1.3.6.1.4.1.52.2501.10.2.9 |
A backup control module that was in standby mode has taken over
for a failed primary control module. Poll sysHwControlModuleBackupState
for current state of backup control module. sysHwModuleSlotNumber is the index
into the sysHwModuleTable for the now active control module. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
envBackupControlModuleFailure |
1.3.6.1.4.1.52.2501.10.2.10 |
A backup control module that was in standby mode has changed to
inactive or notInstalled. Poll sysHwControlModuleBackupState
for current state of backup control module. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
envLineModuleFailure |
1.3.6.1.4.1.52.2501.10.2.11 |
A line card module which was in the online state changed to the
offline state indicating an error condition. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
envCPUThresholdExceeded |
1.3.6.1.4.1.52.2501.10.2.12 |
The CPU utilization has exceeded the value of capCPUMaxThreshold
after having been below the value of capCPUMinThreshold. Once
this trap has occurred it will not occurred again until the
utilization has dropped below capCPUMinThreshold. Poll
capCPUMinThreshold and capCPUMaxThreshold to determine the
configured threshold settings. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
polAclDenied |
1.3.6.1.4.1.52.2501.10.3.0.1 |
The polAclDenied trap indicates that a message was
dropped because of a 'deny' ACL. The polAclName and polAclItem
identify the entry in the polAclTable. The ifIndex value identifies
the interface on which the deny ACL was applied. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
ssrTrapsComplianceV10 |
1.3.6.1.4.1.52.2501.1.300.2.2.1.1 |
The compliance statement for the CTRON-SSR-TRAPS-MIB. |
Status: obsolete |
Access: read-write |
MODULE-COMPLIANCE |
|
|
|
ssrTrapsComplianceV20 |
1.3.6.1.4.1.52.2501.1.300.2.2.2.1 |
The compliance statement for the CTRON-SSR-TRAPS-MIB. |
Status: deprecated |
Access: read-write |
MODULE-COMPLIANCE |
|
|
|
ssrTrapsComplianceV30 |
1.3.6.1.4.1.52.2501.1.300.2.2.3.1 |
The compliance statement for the CTRON-SSR-TRAPS-MIB. |
Status: deprecated |
Access: read-write |
MODULE-COMPLIANCE |
|
|
|
ssrTrapsComplianceV40 |
1.3.6.1.4.1.52.2501.1.300.2.2.4.1 |
The compliance statement for the CTRON-SSR-TRAPS-MIB. |
Status: current |
Access: read-write |
MODULE-COMPLIANCE |
|
|
|
ssrTrapsComplianceV50 |
1.3.6.1.4.1.52.2501.1.300.2.2.5.1 |
The compliance statement for the CTRON-SSR-TRAPS-MIB. |
Status: current |
Access: read-write |
MODULE-COMPLIANCE |
|
|
|
ssrTrapsConfGroupV10 |
1.3.6.1.4.1.52.2501.1.300.2.2.1 |
A set of managed objects that make up version 1.0 of the SSR Trap MIB. |
Status: obsolete |
Access: read-write |
NOTIFICATION-GROUP |
|
|
|
ssrTrapsConfGroupV20 |
1.3.6.1.4.1.52.2501.1.300.2.2.2 |
A set of managed objects that make up version 2.0 of the SSR Trap MIB. |
Status: deprecated |
Access: read-write |
NOTIFICATION-GROUP |
|
|
|
ssrTrapsConfGroupV30 |
1.3.6.1.4.1.52.2501.1.300.2.2.3 |
A set of managed objects that make up version 3.0 of the SSR Trap MIB. |
Status: deprecated |
Access: read-write |
NOTIFICATION-GROUP |
|
|
|
ssrTrapsConfGroupV40 |
1.3.6.1.4.1.52.2501.1.300.2.2.4 |
A set of managed objects that make up version 4.0 of the SSR Trap MIB. |
Status: deprecated |
Access: read-write |
NOTIFICATION-GROUP |
|
|
|
ssrTrapsConfGroupV50 |
1.3.6.1.4.1.52.2501.1.300.2.2.5 |
A set of managed objects that make up version 5.0 of the SSR Trap MIB. |
Status: current |
Access: read-write |
NOTIFICATION-GROUP |
|
|
|