CTTRAPLOG-MIB
File:
CTTRAPLOG-MIB.mib (17219 bytes)
Imported modules
Imported symbols
Defined Types
ConfigTableEntry |
|
SEQUENCE |
|
|
|
|
slotInChassis |
INTEGER |
|
|
numEntriesLoggeds |
Counter |
|
|
numEntriesRequested |
INTEGER |
|
|
numEntriesAllocated |
INTEGER |
|
|
lastLoggedEntryLogId |
INTEGER |
|
|
logCommand |
INTEGER |
|
|
wrap |
INTEGER |
|
TrapLogEntry |
|
SEQUENCE |
|
|
|
|
logId |
INTEGER |
|
|
nvmpId |
INTEGER |
|
|
trapLogAcknowledged |
INTEGER |
|
|
trapLogVarBind |
OCTET STRING |
|
|
trapLogDescription |
DisplayString |
|
|
timeLogged |
TimeTicks |
|
|
filterId |
INTEGER |
|
|
slotChassis |
INTEGER |
|
|
trapOID |
OBJECT IDENTIFIER |
|
|
z80Time |
TimeTicks |
|
FilterEntry |
|
SEQUENCE |
|
|
|
|
filterLogId |
INTEGER |
|
|
filterNvmpId |
INTEGER |
|
|
filterTrapLogAcknowledged |
INTEGER |
|
|
filterTrapLogVarBind |
OCTET STRING |
|
|
filterTrapLogDescription |
DisplayString |
|
|
filterTimeLogged |
TimeTicks |
|
|
filterFilterId |
INTEGER |
|
|
filterSlotInChassis |
INTEGER |
|
|
filterTrapOID |
OBJECT IDENTIFIER |
|
|
filterZ80Time |
TimeTicks |
|
Defined Values
totalNumberOfEntries |
1.3.6.1.4.1.52.4.1.44.1 |
Total number of logged entries for this chassis. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
configTableEntry |
1.3.6.1.4.1.52.4.1.44.2.1 |
Each entry allows a user to configure the alarm table
for a specific slot. Objects such as Current Entry,
MaxEntries Allowed, and an Enable/Disable switch are
available. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
ConfigTableEntry |
|
|
slotInChassis |
1.3.6.1.4.1.52.4.1.44.2.1.1 |
Each Slot can be separately configured. This is the
slot number for the configuration entry. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
numEntriesLoggeds |
1.3.6.1.4.1.52.4.1.44.2.1.2 |
This is the total number of entries looged for this
slot. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
numEntriesRequested |
1.3.6.1.4.1.52.4.1.44.2.1.3 |
Maximum number of entries to store before wrapping
the log on this slot. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
numEntriesAllocated |
1.3.6.1.4.1.52.4.1.44.2.1.4 |
This is the number of entries allocated to log alarms
on this slot. It will always be less than or equal
to the requested number of entries. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
lastLoggedEntryLogId |
1.3.6.1.4.1.52.4.1.44.2.1.5 |
This is the log id of the last entry logged for this
slot. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
logCommand |
1.3.6.1.4.1.52.4.1.44.2.1.6 |
Allows the user to send the log the commands
specified in the enumeration. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
clearLog(1) |
|
wrap |
1.3.6.1.4.1.52.4.1.44.2.1.7 |
This is whether or not this configuration has
wrapped or not. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
trapLogTable |
1.3.6.1.4.1.52.4.1.44.3 |
Tok_String |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
TrapLogEntry |
|
trapLogEntry |
1.3.6.1.4.1.52.4.1.44.3.1 |
Each alarm entry is generated from one of the
following sources; (1) a module in one of the main
chassis slots, (2) the EM, (3) or a power supply. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
TrapLogEntry |
|
|
logId |
1.3.6.1.4.1.52.4.1.44.3.1.1 |
Each slot has a maximium number of log entries that it
can support. Each entry is assigned a monotonically
increasing sequence number. When the maximum number
of entries for a slot is reached, the log wraps. Each
new entry will replace the oldest entry for that slot. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
nvmpId |
1.3.6.1.4.1.52.4.1.44.3.1.2 |
This contains the nvmp id of the trap that occurred. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
trapLogAcknowledged |
1.3.6.1.4.1.52.4.1.44.3.1.3 |
This field is set to 2 if a trap as been acknowledged
from the EM. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
trapLogVarBind |
1.3.6.1.4.1.52.4.1.44.3.1.4 |
This is an ASN.1 encoded string representing the pairs
of OID/value items supplied in the original SNMP or
NVMP trap. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..1500) |
|
trapLogDescription |
1.3.6.1.4.1.52.4.1.44.3.1.5 |
This is an internally defined string used to describe
an alarm. Its primary use is for display on the EMs
LCD. A default value will be used for the old trap
calls. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
timeLogged |
1.3.6.1.4.1.52.4.1.44.3.1.6 |
The time the entry was logged. This will be date and
time if possible. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TimeTicks |
|
|
filterId |
1.3.6.1.4.1.52.4.1.44.3.1.7 |
This will be used to filter certain alarms. The
criteria is TBD. An example of classification:
informational - requires no intervention. warning -
Does not require immediate intervention. e.g. static
risk severe - Requires immediate intervention. e.g.
power overload. fatal - Requires attention and
module may take corrective action such as reboot. e.g.
Unrecoverable software or hardware error. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
informational(1), warning(2), severe(3), fatal(4), existing(5) |
|
slotChassis |
1.3.6.1.4.1.52.4.1.44.3.1.8 |
Slot of this trap log. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
trapOID |
1.3.6.1.4.1.52.4.1.44.3.1.9 |
This OID combines the General Trap code, Specific
Trap code, and the sys object id into one OID. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OBJECT IDENTIFIER |
|
|
z80Time |
1.3.6.1.4.1.52.4.1.44.3.1.10 |
This is the time that the Z80 has been up for the
board that sent this trap. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TimeTicks |
|
|
filterTable |
1.3.6.1.4.1.52.4.1.44.4 |
Tok_String |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
FilterEntry |
|
filterEntry |
1.3.6.1.4.1.52.4.1.44.4.1 |
Each filter entry is generated from one of the
following sources; (1) a module in one of the main
chassis slots, (2) the EM, (3) or a power supply. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
FilterEntry |
|
|
filterLogId |
1.3.6.1.4.1.52.4.1.44.4.1.1 |
Each slot has a maximum number of log entries that it
can support. Each entry is assigned a monotonically
increasing sequence number. When the maximum number of
entries for a slot is reached, the log wraps. Each new
entry willreplace the oldest entry for that slot. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
filterNvmpId |
1.3.6.1.4.1.52.4.1.44.4.1.2 |
This contains the nvmp id of the trap that was
generated. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
filterTrapLogAcknowledged |
1.3.6.1.4.1.52.4.1.44.4.1.3 |
This field is non-zero if a trap has been acknowleged
from the EM. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
filterTrapLogVarBind |
1.3.6.1.4.1.52.4.1.44.4.1.4 |
This is an ASN.1 encoded string representing the pairs
of OID/value items supplied in the original SNMP or
NVMP trap. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..1500) |
|
filterTrapLogDescription |
1.3.6.1.4.1.52.4.1.44.4.1.5 |
This is an internally defined string used to
describe an alarm. It's primary use is for display
on the EMs LCD. A default value will be used for
the old trap calls. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
filterTimeLogged |
1.3.6.1.4.1.52.4.1.44.4.1.6 |
The time the entry was logged. This will be date
and time if possible. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TimeTicks |
|
|
filterFilterId |
1.3.6.1.4.1.52.4.1.44.4.1.7 |
This will be used tofilter certain alarms. The
criteria is TBD. An example of classification:
informational-requires no intervention. warning -
Does not require immediate intervention. e.g.
statis risk severe - Requires immediate
intervention. e.g. power overload. fatal -
Requires attention and module may take
corrective action such as reboot. e.g. Unrecoverale
software or hardware error. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
informational(1), warning(2), severe(3), fatal(4), existing(5) |
|
filterSlotInChassis |
1.3.6.1.4.1.52.4.1.44.4.1.8 |
Slot of this filter entry. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
filterTrapOID |
1.3.6.1.4.1.52.4.1.44.4.1.9 |
This OID combines the General Trap code, Specific
Trap code, and the sys object id into one OID. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OBJECT IDENTIFIER |
|
|
filterZ80Time |
1.3.6.1.4.1.52.4.1.44.4.1.10 |
The number of time ticks that have passed since
this boards Z80 processor has been up. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TimeTicks |
|
|
trapLoggerAgent |
1.3.6.1.4.1.52.4.1.44.5 |
Reflects the operational status of the traplogger agent |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disabled(1), enabled(2), standby(3), elected(4) |
|