DACS-MIB

File: DACS-MIB.mib (754813 bytes)

Imported modules

RFC1155-SMI RFC1213-MIB RFC-1212
RFC-1215

Imported symbols

Counter TimeTicks enterprises
Gauge NetworkAddress IpAddress
DisplayString OBJECT-TYPE TRAP-TYPE

Defined Types

MacAddress  
OCTET STRING Size(6)    

MngEntry  
SEQUENCE    
  mngID INTEGER
  mngIP IpAddress
  mngIPMask IpAddress
  mngTrapMask INTEGER

TrapEntry  
SEQUENCE    
  trapID INTEGER
  trapVal DisplayString
  trapTimeSinceOccurrence TimeTicks

PhysicalConnectorEntry  
SEQUENCE    
  portIdx INTEGER
  physicalConnector INTEGER
  portOptWaveLength INTEGER

PrtSpEntry  
SEQUENCE    
  prtSupervisoryIndex INTEGER
  prtSupervisoryRate INTEGER
  prtSupervisoryDataBits INTEGER
  prtSupervisoryParity INTEGER
  prtSupervisoryStopBits INTEGER
  prtSupervisoryUsage INTEGER
  prtSupervisoryInterface INTEGER
  prtSupervisoryCTS INTEGER
  prtSupervisoryDcdDelay INTEGER
  prtSupervisoryDSR INTEGER
  prtSupervisoryRoutProtocol INTEGER

PrtPerfEntry  
SEQUENCE    
  prtPerfIdx INTEGER
  prtPerfPeriodRef INTEGER
  prtPerfElapsedTime INTEGER
  prtPerfUAS INTEGER
  prtPerfES INTEGER
  prtPerfSES INTEGER
  prtPerfBBE INTEGER
  prtPerfBlocksPerSec INTEGER
  prtPerfTimeTag TimeTicks
  prtPerfSaveAndResetCmd INTEGER

PrtTestEntry  
SEQUENCE    
  prtTestIdx INTEGER
  prtTestCmdAndStatus INTEGER
  prtBertCounter INTEGER
  prtTestInitiator INTEGER

PrtParamEntry  
SEQUENCE    
  prtParamIdx INTEGER
  prtControlCnfg INTEGER

SystemPsEntry  
SEQUENCE    
  systemPsIndex1 INTEGER
  systemPsIndex2 INTEGER
  systemPsType INTEGER

AgnSAlrEntry  
SEQUENCE    
  agnSAlrIdx INTEGER
  agnSAlrCodeDescription DisplayString Size(0..255)
  agnSAlrCode INTEGER
  agnSAlrSeverity INTEGER
  agnSAlrState INTEGER
  agnSAlrCounter INTEGER
  agnSAlrMask INTEGER
  agnSAlrInvert INTEGER

AgnSErrListEntry  
SEQUENCE    
  agnSErrIdx INTEGER
  agnSErrDescription DisplayString Size(0..255)

AgnSCnfgEntry  
SEQUENCE    
  agnSEntryIdx INTEGER
  agnSEntryIsValid INTEGER

AgnCClkSrcEntry  
SEQUENCE    
  agnCClkCnfgIdx INTEGER
  agnCClkSrcIdx INTEGER
  agnCClkSrcMode INTEGER
  agnCClkSrcSlt INTEGER
  agnCClkSrcPrt INTEGER

AgnCnfgDataEntry  
SEQUENCE    
  agnCnfgIdx INTEGER
  agnCnfgDesc DisplayString
  agnCnfgUpdDate DisplayString
  agnCnfgUpdTime DisplayString
  agnCnfgUpdMnger IpAddress

AgnCnfgAlrEntry  
SEQUENCE    
  agnCnfgAlrCode INTEGER
  agnCnfgAlrSlot INTEGER
  agnCnfgAlrPort INTEGER
  agnCnfgAlrMask INTEGER
  agnCnfgAlrInvert INTEGER
  agnCnfgAlrFilter INTEGER
  agnCnfgAlrFilterSet INTEGER
  agnCnfgAlrFilterReset INTEGER

AgnCnfgAlrReportEntry  
SEQUENCE    
  agnCnfgAlrReportType INTEGER
  agnCnfgAlrStartReportOn INTEGER
  agnCnfgAlrStartReportOff INTEGER

AgnCmprEntry  
SEQUENCE    
  agnCmprTypIdx INTEGER
  agnCmprCnfgIdx INTEGER
  agnCmprVersion INTEGER
  agnCmprObj OCTET STRING

AgnDlciCmprEntry  
SEQUENCE    
  agnDlciCmprCnfgIdx INTEGER
  agnDlciCmprVersion INTEGER
  agnDlciCmprDlciIdx INTEGER
  agnDlciCmprObj OCTET STRING

AgnAlarmsCmprEntry  
SEQUENCE    
  agnAlarmsCmprVersion INTEGER
  agnAlarmsCmprAlarmIdx INTEGER
  agnAlarmsCmprObj OCTET STRING

AgnAlrBufCmprEntry  
SEQUENCE    
  agnAlrBufCmprVersion INTEGER
  agnAlrBufCmprAlarmIdx INTEGER
  agnAlrBufCmprObj OCTET STRING

AgnSCmprErrListEntry  
SEQUENCE    
  agnSCmprErrVersion INTEGER
  agnSCmprErrIdx INTEGER
  agnSCmprErrObj OCTET STRING

AgnTsCmprEntry  
SEQUENCE    
  agnTsCmprVerIdx INTEGER
  agnTsCmprCnfgIdx INTEGER
  agnTsCmprSlotIdx INTEGER
  agnTsCmprPortIdx INTEGER
  agnTsCmprPduIdx INTEGER
  agnTsCmprData OCTET STRING

AgnXCmprEntry  
SEQUENCE    
  agnXCmprTypIdx INTEGER
  agnXCmprVersion INTEGER
  agnXCmprIdx3 INTEGER
  agnXCmprIdx4 INTEGER
  agnXCmprIdx5 INTEGER
  agnXCmprIdx6 INTEGER
  agnXCmprIdx7 INTEGER
  agnXCmprObj OCTET STRING

AgnLinkMapEntry  
SEQUENCE    
  mapLinkId INTEGER
  mapLinkSltIdx INTEGER
  mapLinkPrtIdx INTEGER
  mapLinkStatus INTEGER

EthIfEntry  
SEQUENCE    
  ethIfIdx INTEGER
  ethMode INTEGER
  ethBridgingMode INTEGER

AlrBufEntry  
SEQUENCE    
  alrBufIdx INTEGER
  alrBufDescription DisplayString Size(0..255)

AgnCAgendaEntry  
SEQUENCE    
  agnCAgendaCnfgIdx INTEGER
  agnCAgendaDayIdx INTEGER
  agnCAgendaDayCategory INTEGER

AgnCFlipNetEventsEntry  
SEQUENCE    
  agnCFlipNetEventsCnfgIdx INTEGER
  agnCFlipNetEventIdx INTEGER
  agnCFlipNetEventActive INTEGER
  agnCFlipNetEventType INTEGER
  agnCFlipNetEventNo INTEGER
  agnCFlipNetEventSlot INTEGER
  agnCFlipNetEventPort INTEGER
  agnCFlipNetEventISD INTEGER
  agnCFlipNetEventOSD INTEGER
  agnCFlipNetEventDayType INTEGER
  agnCFlipNetEventStartTime DisplayString Size(5)
  agnCFlipNetEventEndTime DisplayString Size(5)

AgnCFlipEntry  
SEQUENCE    
  agnCFlipCnfgIdx INTEGER
  agnCFlipIdx INTEGER
  agnCFlipActive INTEGER
  agnCFlipLogicalExp DisplayString Size(1..20)
  agnCFlipDbNo INTEGER
  agnCFlipDiscardDe INTEGER

AgnListDecodingEntry  
SEQUENCE    
  agnListDecodingType INTEGER
  agnListDecodingCode INTEGER
  agnListDecodingDescription DisplayString Size(0..255)
  agnListDecodingDefState INTEGER
  agnListDecodingSeverity INTEGER
  agnListDecodingAcmRelaySlt INTEGER
  agnListDecodingAcmRelayPrt INTEGER

AgnDlciEntry  
SEQUENCE    
  agnDlciCnfgIdx INTEGER
  agnDlciLSltIdx INTEGER
  agnDlciLPrtIdx INTEGER
  agnDlciLIdx INTEGER
  agnDlciHSltIdx INTEGER
  agnDlciHPrtIdx INTEGER
  agnDlciHIdx INTEGER
  agnDlciTxBc INTEGER
  agnDlciTxBe INTEGER
  agnDlciRxBc INTEGER
  agnDlciRxBe INTEGER
  agnDlciPriority INTEGER
  agnDlciStatus INTEGER
  agnDlciSpoofing INTEGER
  agnDlciFunnelEnable INTEGER
  agnDlciRoutingProtocol INTEGER
  agnDlciRowStatus INTEGER

AgnVoiceSwConfEntry  
SEQUENCE    
  agnVoiceSwConfIdx INTEGER
  agnVoiceSwConfZoneId DisplayString
  agnVoiceSwConfNodeId DisplayString
  agnVoiceSwConfNoOfHops INTEGER

AgnVoiceSwConfRtEntry  
SEQUENCE    
  agnVoiceSwConfRtDbId INTEGER
  agnVoiceSwConfRtIdx INTEGER
  agnVoiceSwConfRtDigits DisplayString
  agnVoiceSwConfRtAction INTEGER
  agnVoiceSwConfRtData DisplayString
  agnVoiceSwConfRtSlot INTEGER
  agnVoiceSwConfRtPort INTEGER
  agnVoiceSwConfRtDlci INTEGER
  agnVoiceSwConfRtRowStatus INTEGER

AgnVoiceSwConfHGEntry  
SEQUENCE    
  agnVoiceSwConfHGdbIdx INTEGER
  agnVoiceSwConfHGIdx INTEGER
  agnVoiceSwConfHGConnect INTEGER
  agnVoiceSwConfHGExt INTEGER

AgnSigProfileEntry  
SEQUENCE    
  agnSigProfileCnfgIdx INTEGER
  agnSigProfileIdx INTEGER
  agnSigProfileRxTx INTEGER
  agnSigProfileABCD OCTET STRING

MdlSInstEntry  
SEQUENCE    
  mdlSInstSltIdx INTEGER
  mdlSInstCardType INTEGER
  mdlSHwVersion DisplayString Size(0..255)
  mdlSSwVersion DisplayString Size(0..255)
  mdlSAlrStatus INTEGER
  mdlSAlrStatusAll INTEGER
  mdlSMaskedAlrStat INTEGER
  mdlSMaskedAlrStatAll INTEGER
  mdlSTstStatusAll INTEGER
  mdlSClearAlrCmd INTEGER
  mdlSClearAllAlrCmd INTEGER

MdlSAlrEntry  
SEQUENCE    
  mdlSAlrSltIdx INTEGER
  mdlSAlrIdx INTEGER
  mdlSAlrCodeDescription DisplayString Size(0..255)
  mdlSAlrCode INTEGER
  mdlSAlrSeverity INTEGER
  mdlSAlrState INTEGER
  mdlSAlrCounter INTEGER
  mdlSAlrMask INTEGER
  mdlSAlrInvert INTEGER

MdlCPrgEntry  
SEQUENCE    
  mdlCCnfgIdx INTEGER
  mdlCSltIdx INTEGER
  mdlCPrgCardType INTEGER
  mdlCNoOfExternPrt INTEGER
  mdlCNoOfInternPrt INTEGER

MdlCmprEntry  
SEQUENCE    
  mdlCmprTypIdx INTEGER
  mdlCmprCnfgIdx INTEGER
  mdlCmprVersion INTEGER
  mdlCmprSltIdx INTEGER
  mdlCmprObj OCTET STRING

MdlAlarmsCmprEntry  
SEQUENCE    
  mdlAlarmsCmprVersion INTEGER
  mdlAlarmsCmprAlarmSlot INTEGER
  mdlAlarmsCmprAlarmIdx INTEGER
  mdlAlarmsCmprObj OCTET STRING

PrtSInstEntry  
SEQUENCE    
  prtSInstSltIdx INTEGER
  prtSInstPrtIdx INTEGER
  prtSInstPrtType INTEGER
  prtSInstIfIndex INTEGER
  prtSActiveStatus INTEGER
  prtSAlrStatus INTEGER
  prtSMaskedAlrStat INTEGER
  prtSClearAlrCmd INTEGER
  prtSTestMask INTEGER
  prtSTstCmd INTEGER
  prtSTstDuration INTEGER
  prtSBertClrCmd INTEGER
  prtSBertTstRslt INTEGER
  prtSInterfaceType DisplayString Size(0..255)
  prtSParamStatus OCTET STRING

PrtSAlrEntry  
SEQUENCE    
  prtSAlrSltIdx INTEGER
  prtSAlrPrtIdx INTEGER
  prtSAlrIdx INTEGER
  prtSAlrCodeDescription DisplayString Size(0..255)
  prtSAlrCode INTEGER
  prtSAlrSeverity INTEGER
  prtSAlrState INTEGER
  prtSAlrCounter INTEGER
  prtSAlrMask INTEGER
  prtSAlrInvert INTEGER

PrtFrStatisEntry  
SEQUENCE    
  prtFrStatisSltIdx INTEGER
  prtFrStatisPrtIdx INTEGER
  prtFrStatisInvIdx INTEGER
  prtFrTimeElapsed INTEGER
  prtFrRxTotalFrames Counter
  prtFrTxTotalFrames Counter
  prtFrRxTotalBytes Counter
  prtFrTxTotalBytes Counter
  prtFrRxMngFrames Counter
  prtFrTxMngFrames Counter
  prtFrRxDeFrames Counter
  prtFrTxDeFrames Counter
  prtFrRxDcrdCongDeFr Counter
  prtFrTxDcrdCongDeFr Counter
  prtFrRxDcrdCongAllFr Counter
  prtFrTxDcrdCongAllFr Counter
  prtFrRxFecn Counter
  prtFrTxFecn Counter
  prtFrRxBecn Counter
  prtFrTxBecn Counter
  prtFrRxBeViol Counter
  prtFrTxBeViol Counter
  prtFrRxBcViol Counter
  prtFrTxBcViol Counter

PrtCrStatisEntry  
SEQUENCE    
  prtCrStatisSltIdx INTEGER
  prtCrStatisPrtIdx INTEGER
  prtCrStatisInvIdx INTEGER
  prtCrTimeElapsed INTEGER
  prtCrRxTotalCells Counter
  prtCrTxTotalCells Counter
  prtCrRxDataCells Counter
  prtCrTxDataCells Counter

PrtDlciStatisEntry  
SEQUENCE    
  prtDlciSltIdx INTEGER
  prtDlciPrtIdx INTEGER
  prtDlciIdx INTEGER
  prtDlciRxDeFrames Counter
  prtDlciTxDeFrames Counter
  prtDlciRxDcrdCongDeFr Counter
  prtDlciTxDcrdCongDeFr Counter
  prtDlciRxDcrdCongAllFr Counter
  prtDlciTxDcrdCongAllFr Counter
  prtDlciTxFecn Counter
  prtDlciTxBecn Counter
  prtDlciRxBeViol Counter
  prtDlciTxBeViol Counter
  prtDlciRxBcViol Counter
  prtDlciTxBcViol Counter

PrtT1FdlMsgEntry  
SEQUENCE    
  prtT1FdlMsgSltIdx INTEGER
  prtT1FdlMsgPrtIdx INTEGER
  prtT1FdlMsgFdlTxRx INTEGER
  prtT1FdlMsg OCTET STRING

PrtExTsSplitEntry  
SEQUENCE    
  prtExTsCnfgIdx INTEGER
  prtExTsSltIdx INTEGER
  prtExTsPrtIdx INTEGER
  prtExTsIdx INTEGER
  prtExTsBit INTEGER
  prtExTsIConSlot INTEGER
  prtExTsIConPrt INTEGER

PrtAgendaBehaviourEntry  
SEQUENCE    
  prtAgendaBehaviourCnfgIdx INTEGER
  prtAgendaBehaviourSltIdx INTEGER
  prtAgendaBehaviourPrtIdx INTEGER
  prtAgendaBehaviourOnOff INTEGER

PrtCnfgAgendaEntry  
SEQUENCE    
  prtCnfgAgendaCnfgIdx INTEGER
  prtCnfgAgendaSltIdx INTEGER
  prtCnfgAgendaPrtIdx INTEGER
  prtCnfgAgendaDayIdx INTEGER
  prtCnfgAgendaSesId INTEGER
  prtCnfgAgendaFrom INTEGER
  prtCnfgAgendaTo INTEGER

PrtGenCnfgEntry  
SEQUENCE    
  prtGenCnfgIdx INTEGER
  prtGenCnfgSltIdx INTEGER
  prtGenCnfgPrtIdx INTEGER
  prtGenCnfgLinkToSlot INTEGER
  prtGenCnfgLinkToPort INTEGER
  prtGenCnfgPortId INTEGER

PrtCmprEntry  
SEQUENCE    
  prtCmprTypIdx INTEGER
  prtCmprCnfgIdx INTEGER
  prtCmprVersion INTEGER
  prtCmprSltIdx INTEGER
  prtCmprPrtIdx INTEGER
  prtCmprObj OCTET STRING

PrtDlciCmprEntry  
SEQUENCE    
  prtDlciCmprCnfgIdx INTEGER
  prtDlciCmprVersion INTEGER
  prtDlciCmprSltIdx INTEGER
  prtDlciCmprPrtIdx INTEGER
  prtDlciCmprDlciIdx INTEGER
  prtDlciCmprObj OCTET STRING

PrtAlarmsCmprEntry  
SEQUENCE    
  prtAlarmsCmprVersion INTEGER
  prtAlarmsCmprAlarmSlot INTEGER
  prtAlarmsCmprAlarmPort INTEGER
  prtAlarmsCmprAlarmIdx INTEGER
  prtAlarmsCmprObj OCTET STRING

PrtSExHsfStatEntry  
SEQUENCE    
  prtSExHsfSltIdx INTEGER
  prtSExHsfPrtIdx INTEGER
  prtSExHsfInterfaceTyp INTEGER
  prtSExHsfRts INTEGER

MdlPbxFramerCnfgEntry  
SEQUENCE    
  mdlPbxFraCnfgIdx INTEGER
  mdlPbxFraSltIdx INTEGER
  mdlPbxFraEnhEcho INTEGER
  mdlPbxFraTSGroupAss INTEGER
  mdlPbxFraSignalMode INTEGER
  mdlPbxFraSignalVector OCTET STRING
  mdlPbxFraSignalMask OCTET STRING
  mdlPbxFraFramerSlot INTEGER
  mdlPbxFraSignaling INTEGER

PrtExClCnfgEntry  
SEQUENCE    
  prtExClCnfgIdx INTEGER
  prtExClSltIdx INTEGER
  prtExClPrtIdx INTEGER
  prtExClUsage INTEGER
  prtExClRate INTEGER
  prtExClDataBits INTEGER
  prtExClParity INTEGER
  prtExClStopBits INTEGER
  prtExClRoutingProtocol INTEGER

PrtExPh1MlCnfgEntry  
SEQUENCE    
  prtExPh1MlCnfgIdx INTEGER
  prtExPh1MlSltIdx INTEGER
  prtExPh1MlPrtIdx INTEGER
  prtExPh1MlConnect INTEGER
  prtExPh1MlLineType INTEGER
  prtExPh1MlLineCode INTEGER
  prtExPh1MlLineLen INTEGER
  prtExPh1MlRestoreTime INTEGER
  prtExPh1MlTxGain INTEGER
  prtExPh1MlRxSensitivity INTEGER
  prtExPh1MlIdleCode INTEGER
  prtExPh1MlTdmTrunk INTEGER
  prtExPh1MlClkMode INTEGER
  prtExPh1MlMfClkSrcSlt INTEGER
  prtExPh1MlMfClkSrcPrt INTEGER
  prtExPh1MlFdlType INTEGER
  prtExPh1MlInbandMng INTEGER
  prtExPh1MlInbandMngRate INTEGER
  prtExPh1MlRedundType INTEGER
  prtExPh1MlRedundSlot INTEGER
  prtExPh1MlRedundPort INTEGER
  prtExPh1MlRedundRecTime INTEGER
  prtExPh1MlInbandMngRoutProt INTEGER
  prtExPh1MlIfType INTEGER

PrtExPh1MlTsEntry  
SEQUENCE    
  prtExPh1MlTsCnfgIdx INTEGER
  prtExPh1MlTsSltIdx INTEGER
  prtExPh1MlTsPrtIdx INTEGER
  prtExPh1MlTsIdx INTEGER
  prtExPh1MlTsIConSlot INTEGER
  prtExPh1MlTsIConPrt INTEGER
  prtExPh1MlTsIConTs INTEGER
  prtExPh1MlTsExt OBJECT IDENTIFIER

PrtInPh1MlCnfgEntry  
SEQUENCE    
  prtInPh1MlCnfgIdx INTEGER
  prtInPh1MlSltType INTEGER
  prtInPh1MlPrtIdx INTEGER
  prtInPh1MlConnect INTEGER
  prtInPh1MlRate INTEGER
  prtInPh1MlProtocol INTEGER
  prtInPh1MlConnectionTyp INTEGER
  prtInPh1MlCongResponse INTEGER
  prtInPh1MlCongLevel INTEGER
  prtInPh1MlTc INTEGER
  prtInPh1MlFlowControl INTEGER
  prtInPh1MlSegment INTEGER
  prtInPh1MlFrMngProt INTEGER
  prtInPh1MlEnqPeriod INTEGER
  prtInPh1MlFullRptPeriod INTEGER
  prtInPh1MlFrWindowSize INTEGER
  prtInPh1MlErrorsThreshold INTEGER
  prtInPh1MlMaxIdleTime INTEGER
  prtInPh1MlBearerCh INTEGER
  prtInPh1MlAssociatedExCh INTEGER
  prtInPh1MlAssociatedExCh INTEGER
  prtInPh1MlClockEncoding INTEGER
  prtInPh1MlMinSeparators INTEGER
  prtInPh1MlCcittCrc INTEGER
  prtInPh1MlFrameSeparator INTEGER

PrtInPh1MlDlciEntry  
SEQUENCE    
  prtInPh1MlDlciCnfgIdx INTEGER
  prtInPh1MlDlciSltIdx INTEGER
  prtInPh1MlDlciPrtIdx INTEGER
  prtInPh1MlDlciIdx INTEGER
  prtInPh1MlDlciValid INTEGER
  prtInPh1MlDlciIConSlt INTEGER
  prtInPh1MlDlciIConPrt INTEGER
  prtInPh1MlDlciIConDlci INTEGER
  prtInPh1MlDlciTxBc INTEGER
  prtInPh1MlDlciTxBe INTEGER
  prtInPh1MlDlciRxBc INTEGER
  prtInPh1MlDlciRxBe INTEGER
  prtInPh1MlDlciPriority INTEGER
  prtInPh1MlDlciStatus INTEGER

PrtPhMlCnfgEntry  
SEQUENCE    
  prtPhMlCnfgIdx INTEGER
  prtPhMlSltIdx INTEGER
  prtPhMlPrtIdx INTEGER
  prtPhMlConnect INTEGER
  prtPhMlRate INTEGER
  prtPhMlCAS INTEGER
  prtPhMlClockMode INTEGER
  prtPhMlSatBuffer INTEGER
  prtPhMlDialProcess INTEGER
  prtPhMlSyncRestore INTEGER
  prtPhMlBus INTEGER
  prtPhMlMfSyncSlot INTEGER

PrtLogicalCnfgEntry  
SEQUENCE    
  prtLogicalCnfgIdx INTEGER
  prtLogicalSltIdx INTEGER
  prtLogicalPrtIdx INTEGER
  prtLogicalConnect INTEGER
  prtLogicalFunction INTEGER
  prtLogicalRowStatus INTEGER

LinkSelectorCnfgEntry  
SEQUENCE    
  linkSelectorCnfgIdx INTEGER
  linkSelectorSltIdx INTEGER
  linkSelectorPrtIdx INTEGER
  linkSelectorMaxIdleTime INTEGER
  linkSelectorMode INTEGER
  linkSelectorRevert INTEGER
  linkSelectorMinBUSession INTEGER

LinkSelectorPLinkEntry  
SEQUENCE    
  pLinkCnfgIdx INTEGER
  pLinkSltIdx INTEGER
  pLinkPrtIdx INTEGER
  pLinkIdx INTEGER
  pLinkSlotNu INTEGER
  pLinkPortNu INTEGER
  pLinkPrioNu INTEGER
  pLinkVRate INTEGER

PrtExPhPlCnfgEntry  
SEQUENCE    
  prtExPhPlCnfgIdx INTEGER
  prtExPhPlSltIdx INTEGER
  prtExPhPlPrtIdx INTEGER
  prtExPhPlConnect INTEGER
  prtExPhPlHRate INTEGER
  prtExPhPlLRate INTEGER
  prtExPhPlProtocol INTEGER
  prtExPhPlConnectionTyp INTEGER
  prtExPhPlClkMode INTEGER
  prtExPhPlDceClkSrc INTEGER
  prtExPhPlCongResponse INTEGER
  prtExPhPlCongLevel INTEGER
  prtExPhPlTc INTEGER
  prtExPhPlFlowControl INTEGER
  prtExPhPlDcdRts INTEGER
  prtExPhPlDcdRtsControlPath INTEGER
  prtExPhPlDataBits INTEGER
  prtExPhPlParity INTEGER
  prtExPhPlStopBits INTEGER
  prtExPhPlLXon INTEGER
  prtExPhPlLXoff INTEGER
  prtExPhPlFrMngProt INTEGER
  prtExPhPlEnqPeriod INTEGER
  prtExPhPlFullRptPeriod INTEGER
  prtExPhPlFrWindowSize INTEGER
  prtExPhPlErrorsThreshold INTEGER
  prtExPhPlPvcCreateMsg INTEGER
  prtExPhPlCllmMsg INTEGER
  prtExPhPlProtDelayLevel INTEGER
  prtExPhPlClockEncoding INTEGER
  prtExPhPlMinSeparators INTEGER
  prtExPhPlCcittCrc INTEGER
  prtExPhPlFrameSeparator INTEGER

PrtExPhPlDlciEntry  
SEQUENCE    
  prtExPhPlDlciCnfgIdx INTEGER
  prtExPhPlDlciSltIdx INTEGER
  prtExPhPlDlciPrtIdx INTEGER
  prtExPhPlDlciIdx INTEGER
  prtExPhPlDlciValid INTEGER
  prtExPhPlDlciIConSlt INTEGER
  prtExPhPlDlciIConPrt INTEGER
  prtExPhPlDlciIConDlci INTEGER
  prtExPhPlDlciTxBc INTEGER
  prtExPhPlDlciTxBe INTEGER
  prtExPhPlDlciRxBc INTEGER
  prtExPhPlDlciRxBe INTEGER
  prtExPhPlDlciPriority INTEGER
  prtExPhPlDlciStatus INTEGER

PrtExPhPlModemEntry  
SEQUENCE    
  prtExPhPlModemCnfgIdx INTEGER
  prtExPhPlModemSltIdx INTEGER
  prtExPhPlModemPrtIdx INTEGER
  prtExPhPlModemStatus INTEGER
  prtExPhPlModemActivate INTEGER
  prtExPhPlModemMaxIdleTime INTEGER
  prtExPhPlModemTimeBtwnCalls INTEGER
  prtExPhPlModemCallDelay INTEGER

PrtExLs2CnfgEntry  
SEQUENCE    
  prtExLs2CnfgIdx INTEGER
  prtExLs2SltIdx INTEGER
  prtExLs2PrtIdx INTEGER
  prtExLs2Connect INTEGER
  prtExLs2Rate INTEGER
  prtExLs2ClkMode INTEGER
  prtExLs2Cts INTEGER
  prtExLs2Dcd INTEGER
  prtExLs2EnvIdx INTEGER

PrtInLs2CnfgEntry  
SEQUENCE    
  prtInLs2CnfgIdx INTEGER
  prtInLs2SltIdx INTEGER
  prtInLs2PrtIdx INTEGER
  prtInLs2Connect INTEGER
  prtInLs2Group INTEGER
  prtInLs2Member INTEGER
  prtInLs2LinkTo INTEGER
  prtInLs2EnvAssign INTEGER

PrtVc2CnfgEntry  
SEQUENCE    
  prtVc2CnfgIdx INTEGER
  prtVc2SltIdx INTEGER
  prtVc2PrtIdx INTEGER
  prtExVc2Connect INTEGER
  prtExVc2TransGain INTEGER
  prtExVc2ReceiveGain INTEGER
  prtExVc2Wire INTEGER
  prtExVc2CodingLaw INTEGER
  prtExVc2Sig INTEGER
  prtExVc2Oos INTEGER
  prtExVc2LinkTo INTEGER
  prtExVc2OperMode INTEGER
  prtExVc2SigProfile INTEGER
  prtExVc2CallEnable INTEGER
  prtExVc2R2Delay INTEGER
  prtExVc2CasStd INTEGER
  prtExVc2EchoCanceler INTEGER
  prtExVc2IfType INTEGER
  prtExVc2Encoding INTEGER
  prtExVc2TxBitCode OCTET STRING
  prtExVc2RxBitOutput OCTET STRING
  prtExVc2MeterRate INTEGER
  prtExVc2IfSignaling INTEGER
  prtExVc2SeizeAck INTEGER
  prtExVc2EandMType INTEGER

PrtHsfCnfgEntry  
SEQUENCE    
  prtHsfCnfgIdx INTEGER
  prtHsfSltIdx INTEGER
  prtHsfPrtIdx INTEGER
  prtExHsfConnect INTEGER
  prtExHsfRate INTEGER
  prtExHsfClkMode INTEGER
  prtExHsfCts INTEGER
  prtExHsfFifoSize INTEGER
  prtExHsfLinkTo INTEGER
  prtExHsfOperMode INTEGER
  prtExHsfInbandLoopback INTEGER
  prtExHsfClkPolarity INTEGER

PrtExHs4CnfgEntry  
SEQUENCE    
  prtExHs4CnfgIdx INTEGER
  prtExHs4SltIdx INTEGER
  prtExHs4PrtIdx INTEGER
  prtExHs4Connect INTEGER
  prtExHs4LineType INTEGER
  prtExHs4LineCode INTEGER
  prtExHs4LineLen INTEGER
  prtExHs4RestoreT INTEGER
  prtExHs4OosSig INTEGER
  prtExHs4OosCode INTEGER
  prtExHs4IdleCode INTEGER
  prtExHs4MfClkSrcSlt INTEGER
  prtExHs4MfClkSrcPrt INTEGER

PrtExHs4TsEntry  
SEQUENCE    
  prtExHs4TsCnfgIdx INTEGER
  prtExHs4TsSltIdx INTEGER
  prtExHs4TsPrtIdx INTEGER
  prtExHs4TsIdx INTEGER
  prtExHs4TsIConSlot INTEGER
  prtExHs4TsIConPrt INTEGER
  prtExHs4TsIConTs INTEGER

PrtExHsiCnfgEntry  
SEQUENCE    
  prtExHsiCnfgIdx INTEGER
  prtExHsiSltIdx INTEGER
  prtExHsiPrtIdx INTEGER
  prtExHsiConnect INTEGER
  prtExHsiRate INTEGER
  prtExHsiLinkTo INTEGER
  prtExHsiInterface INTEGER
  prtExHsiActType INTEGER

PrtInHsiCnfgEntry  
SEQUENCE    
  prtInHsiCnfgIdx INTEGER
  prtInHsiSltIdx INTEGER
  prtInHsiPrtIdx INTEGER
  prtInHsiConnect INTEGER
  prtInHsiRate INTEGER
  prtInHsiConcentratedTo INTEGER

PrtExHsrCnfgEntry  
SEQUENCE    
  prtExHsrCnfgIdx INTEGER
  prtExHsrSltIdx INTEGER
  prtExHsrPrtIdx INTEGER
  prtExHsrConnect INTEGER
  prtExHsrProtocol INTEGER
  prtExHsrRate INTEGER
  prtExHsrDataBits INTEGER
  prtExHsrParity INTEGER
  prtExHsrStopBits INTEGER
  prtExHsrCts INTEGER
  prtExHsrClkMode INTEGER
  prtExHsrLinkTo INTEGER
  prtExHsrDcdDsr INTEGER
  prtExHsrOperMode INTEGER
  prtExHsrRtsDtr INTEGER
  prtExHsrLlbEnable INTEGER
  prtExHsrRlbEnable INTEGER
  prtExHsrRateAdapt INTEGER

PrtExMbeCnfgEntry  
SEQUENCE    
  prtExMbeCnfgIdx INTEGER
  prtExMbeSltIdx INTEGER
  prtExMbePrtIdx INTEGER
  prtExMbeLan INTEGER

PrtInMbeCnfgEntry  
SEQUENCE    
  prtInMbeCnfgIdx INTEGER
  prtInMbeSltIdx INTEGER
  prtInMbePrtIdx INTEGER
  prtInMbeConnect INTEGER
  prtInMbeRate INTEGER
  prtInMbeLinkTo INTEGER

PrtExTreCnfgEntry  
SEQUENCE    
  prtExTreCnfgIdx INTEGER
  prtExTreSltIdx INTEGER
  prtExTrePrtIdx INTEGER
  prtExTreLan INTEGER
  prtExTreLanRate INTEGER

PrtInTreCnfgEntry  
SEQUENCE    
  prtInTreCnfgIdx INTEGER
  prtInTreSltIdx INTEGER
  prtInTrePrtIdx INTEGER
  prtInTreConnect INTEGER
  prtInTreRate INTEGER
  prtInTreLinkTo INTEGER

PrtExPVc4CnfgEntry  
SEQUENCE    
  prtExPVc4CnfgIdx INTEGER
  prtExPVc4SltIdx INTEGER
  prtExPVc4PrtIdx INTEGER
  prtExPVc4PrtType INTEGER
  prtExPVc4Connect INTEGER
  prtExPVc4IfType INTEGER
  prtExPVc4TxGain INTEGER
  prtExPVc4RxGain INTEGER
  prtExPVc4MaxRate INTEGER
  prtExPVc4Tc INTEGER
  prtExPVc4Oos INTEGER
  prtExPVc4EchoCanceler INTEGER
  prtExPVc4VarDelay INTEGER
  prtExPVc4CongLevel INTEGER
  prtExPVc4Wire INTEGER
  prtExPVc4ExtensionType INTEGER
  prtExPVc4ExtensionNumber DisplayString
  prtExPVc4OutPulsing INTEGER
  prtExPVc4HuntGroupMb INTEGER
  prtExPVc4HuntGroupIdx INTEGER
  prtExPVc4AutoFaxMode INTEGER
  prtExPVc4FaxRate INTEGER
  prtExPVc4SeizeAck INTEGER
  prtExPVc4SignalingProtocol INTEGER
  prtExPVc4DelayStart INTEGER
  prtExPVc4WinkMinDuration INTEGER
  prtExPVc4WinkMaxDuration INTEGER

PrtExPVc4DlciEntry  
SEQUENCE    
  prtExPVc4DlciCnfgIdx INTEGER
  prtExPVc4DlciSltIdx INTEGER
  prtExPVc4DlciPrtIdx INTEGER
  prtExPVc4DlciValid INTEGER
  prtExPVc4DlciIConSlt INTEGER
  prtExPVc4DlciIConPrt INTEGER
  prtExPVc4DlciIConDlci INTEGER
  prtExPVc4DlciTxBc INTEGER
  prtExPVc4DlciTxBe INTEGER
  prtExPVc4DlciRxBc INTEGER
  prtExPVc4DlciRxBe INTEGER
  prtExPVc4DlciPriority INTEGER
  prtExPVc4DlciStatus INTEGER

PrtExLs6CnfgEntry  
SEQUENCE    
  prtExLs6CnfgIdx INTEGER
  prtExLs6SltIdx INTEGER
  prtExLs6PrtIdx INTEGER
  prtExLs6Connect INTEGER
  prtExLs6Protocol INTEGER
  prtExLs6Rate INTEGER
  prtExLs6ClkMode INTEGER
  prtExLs6CtrlSignal INTEGER
  prtExLs6DataBits INTEGER
  prtExLs6Cts INTEGER
  prtExLs6LinkToInternal INTEGER

PrtExLs6VCnfgEntry  
SEQUENCE    
  prtExLs6VCnfgIdx INTEGER
  prtExLs6VSltIdx INTEGER
  prtExLs6VPrtIdx INTEGER
  prtExLs6VConnect INTEGER
  prtExLs6VRate INTEGER
  prtExLs6VEchoCanceler INTEGER
  prtExLs6VIfType INTEGER
  prtExLs6VTxGain INTEGER
  prtExLs6VRxGain INTEGER
  prtExLs6VOos INTEGER

PrtInLs6CnfgEntry  
SEQUENCE    
  prtInLs6CnfgIdx INTEGER
  prtInLs6SltIdx INTEGER
  prtInLs6PrtIdx INTEGER
  prtInLs6Connect INTEGER
  prtInLs6TandemMode INTEGER
  prtInLs6Rate INTEGER
  prtInLs6RemoteType INTEGER
  prtInLs6LinkTo INTEGER

PrtExVc3CnfgEntry  
SEQUENCE    
  prtExVc3CnfgIdx INTEGER
  prtExVc3SltIdx INTEGER
  prtExVc3PrtIdx INTEGER
  prtExVc3Connect INTEGER
  prtExVc3TransGain INTEGER
  prtExVc3ReceiveGain INTEGER
  prtExVc3Wire INTEGER
  prtExVc3Rate INTEGER
  prtExVc3EchoCanceler INTEGER

PrtInVc3CnfgEntry  
SEQUENCE    
  prtInVc3CnfgIdx INTEGER
  prtInVc3SltIdx INTEGER
  prtInVc3PrtIdx INTEGER
  prtInVc3Connect INTEGER
  prtInVc3Rate INTEGER
  prtInVc3Oos INTEGER
  prtInVc3LinkTo INTEGER

PrtExVcPbxCnfgEntry  
SEQUENCE    
  prtExVcPbxCnfgIdx INTEGER
  prtExVcPbxSltIdx INTEGER
  prtExVcPbxPrtIdx INTEGER
  prtExVcPbxConnect INTEGER
  prtExVcPbxGroup INTEGER
  prtExVcPbxTransparent INTEGER
  prtExVcPbxTransSignalTs INTEGER
  prtExVcPbxFrame INTEGER
  prtExVcPbxRestoreTime INTEGER
  prtExVcPbxLineCode INTEGER
  prtExVcPbxLineLength INTEGER
  prtExVcPbxLinkTo INTEGER
  prtExVcPbxSignalOper INTEGER
  prtExVcPbxIdleCode INTEGER

PrtIn1p6VcPbxCnfgEntry  
SEQUENCE    
  prtIn1p6VcPbxCnfgIdx INTEGER
  prtIn1p6VcPbxSltIdx INTEGER
  prtIn1p6VcPbxPrtIdx INTEGER
  prtIn1p6VcPbxConnect INTEGER
  prtIn1p6VcPbxRate INTEGER
  prtIn1p6VcPbxEchoCanceler INTEGER
  prtIn1p6VcPbxPabxTs INTEGER

PrtIn7p8VcPbxCnfgEntry  
SEQUENCE    
  prtIn7p8VcPbxCnfgIdx INTEGER
  prtIn7p8VcPbxSltIdx INTEGER
  prtIn7p8VcPbxPrtIdx INTEGER
  prtIn7p8VcPbxConnect INTEGER
  prtIn7p8VcPbxMode INTEGER
  prtIn7p8VcPbxRate INTEGER
  prtIn7p8VcPbxSignalMode INTEGER
  prtIn7p8VcPbxOos INTEGER
  prtIn7p8VcPbxLinkTo INTEGER

PrtExVcPbxTsEntry  
SEQUENCE    
  prtExVcPbxTsCnfgIdx INTEGER
  prtExVcPbxTsSltIdx INTEGER
  prtExVcPbxTsPrtIdx INTEGER
  prtExVcPbxTsIdx INTEGER
  prtExVcPbxTsMode INTEGER
  prtExVcPbxTsIConSlot INTEGER
  prtExVcPbxTsIConPrt INTEGER

PrtIsdnCnfgEntry  
SEQUENCE    
  prtIsdnCnfgIdx INTEGER
  prtIsdnSltIdx INTEGER
  prtIsdnPrtIdx INTEGER
  prtIsdnConnect INTEGER
  prtIsdnSignalingProtocol INTEGER
  prtIsdnBasicRateLineTopology INTEGER
  prtIsdnMode INTEGER
  prtIsdnFilter INTEGER
  prtIsdnSimultaneousCall INTEGER
  prtIsdnNumOfAbstractTerm INTEGER
  prtIsdnSwitchMode INTEGER

PrtIsdnEndpointEntry  
SEQUENCE    
  prtIsdnEndpointCnfgIdx INTEGER
  prtIsdnEndpointSltIdx INTEGER
  prtIsdnEndpointPrtIdx INTEGER
  prtIsdnEndpointIdx INTEGER
  prtIsdnEndpointTeiType INTEGER
  prtIsdnEndpointTeiValue INTEGER
  prtIsdnEndpointSpid DisplayString
  prtIsdnEndpointBearerCh INTEGER
  prtIsdnEndpointRowStatus INTEGER

PrtIsdnDirectoryEntry  
SEQUENCE    
  prtIsdnDirectoryCnfgIdx INTEGER
  prtIsdnDirectorySltIdx INTEGER
  prtIsdnDirectoryPrtIdx INTEGER
  prtIsdnDirectoryLocalAddr DisplayString
  prtIsdnDirectoryLocalSubAddr DisplayString
  prtIsdnDirectoryRemoteAddr DisplayString
  prtIsdnDirectoryRemoteSubAddr DisplayString
  prtIsdnDirectoryPrtNu INTEGER
  prtIsdnDirectoryTeiId INTEGER
  prtIsdnDirectoryRowStatus INTEGER
  prtIsdnDirectoryLocalAddr2 DisplayString
  prtIsdnDirectoryLocalSubAddr2 DisplayString
  prtIsdnDirectoryRemoteAddr2 DisplayString
  prtIsdnDirectoryRemoteSubAddr2 DisplayString

PrtFrPlusCnfgEntry  
SEQUENCE    
  prtFrPlusCnfgIdx INTEGER
  prtFrPlusSltIdx INTEGER
  prtFrPlusPrtIdx INTEGER
  prtFrPlusNotSegmentedPriorities OCTET STRING

PrtMl4CnfgEntry  
SEQUENCE    
  prtMl4CnfgIdx INTEGER
  prtMl4SltIdx INTEGER
  prtMl4PrtIdx INTEGER
  prtMl4SigProfile INTEGER
  prtMl4CGA INTEGER
  prtMl4Oos INTEGER
  prtMl4VoiceOos OCTET STRING
  prtMl4DataOos OCTET STRING
  prtMl4Service INTEGER

PrtAcmCnfgEntry  
SEQUENCE    
  prtAcmCnfgIdx INTEGER
  prtAcmSltIdx INTEGER
  prtAcmPrtIdx INTEGER
  prtAcmConnect INTEGER
  prtAcmActiveState INTEGER
  prtAcmAlrString DisplayString

AgnTsEntry  
SEQUENCE    
  agnTsCnfgIdx INTEGER
  agnTsSltIdx INTEGER
  agnTsPrtIdx INTEGER
  agnTsIdx INTEGER
  agnTsBitIdx INTEGER
  agnTsConSltIdx INTEGER
  agnTsConPrtIdx INTEGER
  agnTsConIdx INTEGER
  agnTsType INTEGER
  agnTsRowStatus INTEGER
  agnTsDirection INTEGER

SysDclEntry  
SEQUENCE    
  sysDclCnfgIdx INTEGER
  sysDclRedundancy INTEGER
  sysDclActiveCl INTEGER
  sysDclFlipDelay INTEGER

SysDclCopyDbEntry  
SEQUENCE    
  sysDclCopyDbIdx INTEGER
  sysDclCopyDbCmd INTEGER

SysSErrListEntry  
SEQUENCE    
  sysSErrType INTEGER
  sysSErrIdx INTEGER
  sysSErrDescription DisplayString Size(0..255)

SysSRdnFlipEntry  
SEQUENCE    
  sysSRdnFlipIdx INTEGER
  sysSRdnFlipSlot INTEGER
  sysSRdnFlipPort INTEGER
  sysSRdnFlipCause DisplayString
  sysSRdnFlipDate DisplayString
  sysSRdnFlipTime DisplayString

SysSAlrEntry  
SEQUENCE    
  sysSAlrIdx INTEGER
  sysSAlrCode INTEGER
  sysSAlrState INTEGER
  sysSAlarmMask INTEGER
  sysSAlarmInvert INTEGER

SysBufferAlrEntry  
SEQUENCE    
  sysBufferAlrIdx INTEGER
  sysBufferAlrCode INTEGER
  sysBufferAlrState INTEGER
  sysBufferAlrSlot INTEGER
  sysBufferAlrPort INTEGER
  sysBufferAlrDate DisplayString
  sysBufferAlrTime DisplayString

SysCClkSrcEntry  
SEQUENCE    
  sysCClkCnfgIdx INTEGER
  sysCClkSrcIdx INTEGER
  sysCClkSrcMode INTEGER
  sysCClkSrcPrt INTEGER
  sysCClkStationFreq INTEGER

SysCnfgEntry  
SEQUENCE    
  sysCnfgIdx INTEGER
  sysCMatrixMode INTEGER
  sysCIsdnFormat INTEGER
  sysCRoutingOnEth INTEGER

SysCRdnEntry  
SEQUENCE    
  sysCRdnCnfgIdx INTEGER
  sysCRdnPrimeSlot INTEGER
  sysCRdnPrimePort INTEGER
  sysCRdnSecSlot INTEGER
  sysCRdnSecPort INTEGER
  sysCRdnMode INTEGER
  sysCRdnRecMode INTEGER
  sysCRdnRecTime INTEGER
  sysCRdnHwSwFlip INTEGER
  sysCRdnRowStatus INTEGER
  sysCRdnOnline INTEGER

SysDbaseFlipEntry  
SEQUENCE    
  sysDbaseFlipIdx INTEGER
  sysDbaseFlipTime DisplayString
  sysDbaseFlipActivation INTEGER

MdlSEntry  
SEQUENCE    
  mdlSSltIdx INTEGER
  mdlSCardType INTEGER
  mdlSHwVer DisplayString Size(0..255)
  mdlSSwVer DisplayString Size(0..255)
  mdlSAlarmStatus INTEGER
  mdlSAlarmStatusAll INTEGER
  mdlSTestStatus INTEGER
  mdlSHwStatus INTEGER
  mdlSActivity INTEGER
  mdlSAlrClearCmd INTEGER
  mdlSAlrClearAllCmd INTEGER
  mdlSAlrMaskAll INTEGER
  mdlSCmd INTEGER

MdlCEntry  
SEQUENCE    
  mdlCConfigIdx INTEGER
  mdlCSlotIdx INTEGER
  mdlCProgCardType INTEGER
  mdlCNoOfExtPrt INTEGER
  mdlCNoOfIntPrt INTEGER

MdlAlrEntry  
SEQUENCE    
  mdlAlrSltIdx INTEGER
  mdlAlrIdx INTEGER
  mdlAlrCode INTEGER
  mdlAlrState INTEGER
  mdlAlarmMask INTEGER
  mdlAlarmInvert INTEGER

MdlAlrMaskEntry  
SEQUENCE    
  mdlAlrMaskSltIdx INTEGER
  mdlAlrMask OCTET STRING

MdlClEntry  
SEQUENCE    
  mdlClIdx INTEGER
  mdlClSwchStatus INTEGER
  mdlClLastFlipDate DisplayString
  mdlClLastFlipTime DisplayString
  mdlClLastFlipCause DisplayString

MdlPsEntry  
SEQUENCE    
  mdlPsIdx INTEGER
  mdlPsStatus INTEGER
  mdlPsTestResult INTEGER

PrtGenEntry  
SEQUENCE    
  prtGenPrtIdx INTEGER
  prtGenSlt INTEGER
  prtGenExtInt INTEGER
  prtGenIfIndex INTEGER
  prtGenActiveStatus INTEGER
  prtGenAlrStatus INTEGER
  prtGenTestStatus INTEGER
  prtGenTestMask INTEGER
  prtGenTestCmd INTEGER
  prtGenTestRunning INTEGER
  prtGenType INTEGER
  prtGenInterfaceType DisplayString Size(0..255)
  prtGenAlrClearCmd INTEGER
  prtGenAlrMaskAll INTEGER
  prtGenParamStatus OCTET STRING

PrtGenTestDurationEntry  
SEQUENCE    
  prtGenTestPrtIdx INTEGER
  prtGenTestIdx INTEGER
  prtGenTestDuration INTEGER

PrtGenTsEntry  
SEQUENCE    
  prtGenTsCnfgIdx INTEGER
  prtGenTsPrtIdx INTEGER
  prtGenTsIdx INTEGER
  prtGenTsType INTEGER
  prtGenTsIConPrt INTEGER
  prtGenTsIConTs INTEGER

PrtSAlarmEntry  
SEQUENCE    
  prtSAlarmPrtIdx INTEGER
  prtSAlarmIdx INTEGER
  prtSAlarmCode INTEGER
  prtSAlarmState INTEGER
  prtSAlarmMask INTEGER
  prtSAlarmInvert INTEGER

PrtAlrMaskEntry  
SEQUENCE    
  prtAlrMaskPrtIdx INTEGER
  prtAlrMask OCTET STRING

PrtBertEntry  
SEQUENCE    
  prtBertPrtIdx INTEGER
  prtBertPattern INTEGER
  prtBertInjectRate INTEGER
  prtBertInjectErrRateCmd INTEGER
  prtBertInjectSingleErrCmd INTEGER
  prtBertRunTime INTEGER
  prtBertESs INTEGER
  prtBertSyncLoss INTEGER
  prtBertErrorBits INTEGER
  prtBertClearCounters INTEGER
  prtBertSyncStatus INTEGER
  prtBertTs OCTET STRING

PrtMonEntry  
SEQUENCE    
  prtMonCnfgIdx INTEGER
  prtMonitoringIdx INTEGER
  prtMonitoringEnable INTEGER
  prtMonitoringTSs OCTET STRING
  prtMonitoredPort INTEGER
  prtMonitoredTSs OCTET STRING

PrtCfgParamEntry  
SEQUENCE    
  prtCfgParamCnfgIdx INTEGER
  prtCfgParamIdx INTEGER
  prtCfgParamSlt INTEGER
  prtCfgParamOperatedMl INTEGER
  prtCfgParamMlAtoMlBPrio INTEGER
  prtCfgParamMlBtoMlAPrio INTEGER
  prtCfgParamInbandLoopDetection INTEGER

PrtT1E1StatEntry  
SEQUENCE    
  prtT1E1SPrtIdx INTEGER
  prtT1E1SSlt INTEGER
  prtT1E1OosCount Gauge
  prtT1E1BpvLastMin Gauge
  prtT1E1BpvMax Gauge

PrtT1E1CnfgEntry  
SEQUENCE    
  prtT1E1CnfgIdx INTEGER
  prtT1E1PrtIdx INTEGER
  prtT1E1Slt INTEGER
  prtT1E1LineType INTEGER
  prtT1E1LineCode INTEGER
  prtT1E1SignalMode INTEGER
  prtT1E1Fdl INTEGER
  prtT1E1FdlMode INTEGER
  prtT1E1Sync INTEGER
  prtT1E1CGA INTEGER
  prtT1E1IdleCode OCTET STRING
  prtT1E1OosSignal INTEGER
  prtT1E1VoiceOos OCTET STRING
  prtT1E1DataOos OCTET STRING
  prtT1E1LineLengthMask INTEGER
  prtT1E1TxGainMask INTEGER
  prtT1E1InbandMng INTEGER
  prtT1E1InbandMngRate INTEGER
  prtT1E1DedicatedTs INTEGER
  prtT1E1InbandMngRoutProt INTEGER
  prtT1E1LinkMode INTEGER
  prtT1E1Multiplier INTEGER
  prtT1E1RxGain INTEGER
  prtT1E1RAI INTEGER
  prtT1E1LineMode INTEGER
  prtT1E1TS0SaBits OCTET STRING

PrtT1E1FdlMsgEntry  
SEQUENCE    
  prtT1E1FdlMsgPrtIdx INTEGER
  prtT1E1FdlMsgFdlType INTEGER
  prtT1E1FdlMsgSlt INTEGER
  prtT1E1FdlMsg OCTET STRING

PrtHSParamEntry  
SEQUENCE    
  prtHSCnfgIdx INTEGER
  prtHSPrtIdx INTEGER
  prtHSSlt INTEGER
  prtHSRate INTEGER
  prtHSFifoSize INTEGER
  prtHSClkMode INTEGER
  prtHSCTS INTEGER
  prtHSRtsState INTEGER

PrtHSBertEntry  
SEQUENCE    
  prtHSBertPrtIdx INTEGER
  prtHSBertSlt INTEGER
  prtHSBertCountClr INTEGER
  prtHSBertTestResult INTEGER

PrtSpCnfgEntry  
SEQUENCE    
  prtSpCnfgIdx INTEGER
  prtSpPrtIdx INTEGER
  prtSpUsage INTEGER
  prtSpRate INTEGER
  prtSpDataBits INTEGER
  prtSpParity INTEGER
  prtSpCallOutMode INTEGER
  prtSpInterface INTEGER
  prtSpCTS INTEGER
  prtSpDcdDelay INTEGER
  prtSpDsr INTEGER
  prtSpNoOfRetries INTEGER
  prtSpWaitForConnect INTEGER
  prtSpDialMode INTEGER
  prtSpAltNumMode INTEGER
  prtSpPrimaryNum DisplayString
  prtSpAltNum DisplayString
  prtSpRoutProtocol INTEGER
  prtSpCmd OCTET STRING
  prtSpActCallOut INTEGER
  prtSpAlrRelayMode INTEGER

PrtDimCnfgEntry  
SEQUENCE    
  prtDimCnfgIdx INTEGER
  prtDimIdx INTEGER
  prtDimTxMode INTEGER
  prtDimPolarity INTEGER
  prtDimClkMode INTEGER
  prtDimMaxDelay INTEGER
  prtDimMng INTEGER

PrtDimDestEntry  
SEQUENCE    
  prtDestCnfgIdx INTEGER
  prtDestDimIdx INTEGER
  prtDestIdx INTEGER
  prtDest INTEGER
  prtDestConnect INTEGER

PrtICnfgEntry  
SEQUENCE    
  prtICnfgIdx INTEGER
  prtIIdx INTEGER
  prtIRate INTEGER
  prtIConnect INTEGER

PrtHdslEntry  
SEQUENCE    
  prtHdslIdx INTEGER
  prtHdslMode INTEGER
  prtHdslRptrType INTEGER

PrtT3E3CnfgEntry  
SEQUENCE    
  prtT3E3CnfgIdx INTEGER
  prtT3E3PrtIdx INTEGER
  prtT3E3Slt INTEGER
  prtT3E3LineLength INTEGER
  prtT3E3InbandMng INTEGER

CmprEntry  
SEQUENCE    
  cmprTypeIdx INTEGER
  cmprCnfgIdx INTEGER
  cmprVersion INTEGER
  cmprSltIdx INTEGER
  cmprPrtIdx INTEGER
  cmprObj OCTET STRING

MapLinkEntry  
SEQUENCE    
  mapLinkIdx INTEGER
  mapLinkSlotIdx INTEGER
  mapLinkPortIdx INTEGER
  mapLinkState INTEGER

AlrGenEntry  
SEQUENCE    
  alrGenCode INTEGER
  alrGenDescription DisplayString Size(0..255)
  alrGenLevel INTEGER
  alrGenSlotType INTEGER
  alrGenSeverity INTEGER
  alrGenDebounce INTEGER

Defined Values

rad 1.3.6.1.4.1.164
OBJECT IDENTIFIER    

radTokenRing 1.3.6.1.4.1.164.1
OBJECT IDENTIFIER    

radFddi 1.3.6.1.4.1.164.2
OBJECT IDENTIFIER    

radWan 1.3.6.1.4.1.164.3
OBJECT IDENTIFIER    

radBridges 1.3.6.1.4.1.164.4
OBJECT IDENTIFIER    

radConverters 1.3.6.1.4.1.164.5
OBJECT IDENTIFIER    

radGen 1.3.6.1.4.1.164.6
OBJECT IDENTIFIER    

radStkHub 1.3.6.1.4.1.164.7
OBJECT IDENTIFIER    

systems 1.3.6.1.4.1.164.6.1
OBJECT IDENTIFIER    

radSysTR 1.3.6.1.4.1.164.6.1.1
OBJECT IDENTIFIER    

radRADring 1.3.6.1.4.1.164.6.1.1.1
OBJECT IDENTIFIER    

radTMA 1.3.6.1.4.1.164.6.1.1.2
OBJECT IDENTIFIER    

radRingMonitor 1.3.6.1.4.1.164.6.1.1.3
OBJECT IDENTIFIER    

radSysFddi 1.3.6.1.4.1.164.6.1.2
OBJECT IDENTIFIER    

radFDX100 1.3.6.1.4.1.164.6.1.2.1
OBJECT IDENTIFIER    

radSysWan 1.3.6.1.4.1.164.6.1.3
OBJECT IDENTIFIER    

radMP2100 1.3.6.1.4.1.164.6.1.3.1
OBJECT IDENTIFIER    

radMP2104 1.3.6.1.4.1.164.6.1.3.2
OBJECT IDENTIFIER    

radMP2100B 1.3.6.1.4.1.164.6.1.3.3
OBJECT IDENTIFIER    

radMP2100F 1.3.6.1.4.1.164.6.1.3.4
OBJECT IDENTIFIER    

radMP2100H 1.3.6.1.4.1.164.6.1.3.5
OBJECT IDENTIFIER    

radMP2104H 1.3.6.1.4.1.164.6.1.3.6
OBJECT IDENTIFIER    

radMP2200B 1.3.6.1.4.1.164.6.1.3.7
OBJECT IDENTIFIER    

radMP2200F 1.3.6.1.4.1.164.6.1.3.8
OBJECT IDENTIFIER    

radMX3000 1.3.6.1.4.1.164.6.1.3.9
OBJECT IDENTIFIER    

radMX3004 1.3.6.1.4.1.164.6.1.3.10
OBJECT IDENTIFIER    

radMX30 1.3.6.1.4.1.164.6.1.3.11
OBJECT IDENTIFIER    

radMX300 1.3.6.1.4.1.164.6.1.3.12
OBJECT IDENTIFIER    

radVOIP 1.3.6.1.4.1.164.6.1.3.13
OBJECT IDENTIFIER    

radKM2100 1.3.6.1.4.1.164.6.1.3.15
OBJECT IDENTIFIER    

radKM2104 1.3.6.1.4.1.164.6.1.3.16
OBJECT IDENTIFIER    

radDXC30 1.3.6.1.4.1.164.6.1.3.20
OBJECT IDENTIFIER    

radDXC10A 1.3.6.1.4.1.164.6.1.3.21
OBJECT IDENTIFIER    

radDXC8R 1.3.6.1.4.1.164.6.1.3.22
OBJECT IDENTIFIER    

radDXC30E 1.3.6.1.4.1.164.6.1.3.23
OBJECT IDENTIFIER    

radFcdT1 1.3.6.1.4.1.164.6.1.3.30
OBJECT IDENTIFIER    

radFcdE1 1.3.6.1.4.1.164.6.1.3.31
OBJECT IDENTIFIER    

radFcdE1I 1.3.6.1.4.1.164.6.1.3.32
OBJECT IDENTIFIER    

radFcdT1M 1.3.6.1.4.1.164.6.1.3.33
OBJECT IDENTIFIER    

radFcdE1M 1.3.6.1.4.1.164.6.1.3.34
OBJECT IDENTIFIER    

radFcdIP 1.3.6.1.4.1.164.6.1.3.35
OBJECT IDENTIFIER    

radFcdT1A 1.3.6.1.4.1.164.6.1.3.36
OBJECT IDENTIFIER    

radFcdE1A 1.3.6.1.4.1.164.6.1.3.37
OBJECT IDENTIFIER    

radFcdW 1.3.6.1.4.1.164.6.1.3.38
OBJECT IDENTIFIER    

radHtuE1Sa 1.3.6.1.4.1.164.6.1.3.40
OBJECT IDENTIFIER    

radHtuE1 1.3.6.1.4.1.164.6.1.3.41
OBJECT IDENTIFIER    

radHtu2Sa 1.3.6.1.4.1.164.6.1.3.42
OBJECT IDENTIFIER    

radHtu2 1.3.6.1.4.1.164.6.1.3.43
OBJECT IDENTIFIER    

radAsmi450R768Sa 1.3.6.1.4.1.164.6.1.3.44
OBJECT IDENTIFIER    

radAsmi450R768 1.3.6.1.4.1.164.6.1.3.45
OBJECT IDENTIFIER    

radAsmi450R1152Sa 1.3.6.1.4.1.164.6.1.3.46
OBJECT IDENTIFIER    

radAsmi450R1152 1.3.6.1.4.1.164.6.1.3.47
OBJECT IDENTIFIER    

radLrs12F 1.3.6.1.4.1.164.6.1.3.48
OBJECT IDENTIFIER    

radLrs12B 1.3.6.1.4.1.164.6.1.3.49
OBJECT IDENTIFIER    

radHcdE1Sa 1.3.6.1.4.1.164.6.1.3.51
OBJECT IDENTIFIER    

radHcdE1 1.3.6.1.4.1.164.6.1.3.52
OBJECT IDENTIFIER    

radHtuT1Sa 1.3.6.1.4.1.164.6.1.3.53
OBJECT IDENTIFIER    

radHtuT1 1.3.6.1.4.1.164.6.1.3.54
OBJECT IDENTIFIER    

radOptimux4E1 1.3.6.1.4.1.164.6.1.3.55
OBJECT IDENTIFIER    

radOptimux4T1 1.3.6.1.4.1.164.6.1.3.56
OBJECT IDENTIFIER    

radOptimuxXLE1 1.3.6.1.4.1.164.6.1.3.57
OBJECT IDENTIFIER    

radOptimuxXLT1 1.3.6.1.4.1.164.6.1.3.58
OBJECT IDENTIFIER    

radOptimuxXL16E1 1.3.6.1.4.1.164.6.1.3.59
OBJECT IDENTIFIER    

radImx64 1.3.6.1.4.1.164.6.1.3.60
OBJECT IDENTIFIER    

radImx6L 1.3.6.1.4.1.164.6.1.3.61
OBJECT IDENTIFIER    

radImx2 1.3.6.1.4.1.164.6.1.3.62
OBJECT IDENTIFIER    

radImx4T1 1.3.6.1.4.1.164.6.1.3.63
OBJECT IDENTIFIER    

radImx4E1 1.3.6.1.4.1.164.6.1.3.64
OBJECT IDENTIFIER    

radImx2T1E1 1.3.6.1.4.1.164.6.1.3.65
OBJECT IDENTIFIER    

radHtuE1SaV2 1.3.6.1.4.1.164.6.1.3.70
OBJECT IDENTIFIER    

radHtuE1V2 1.3.6.1.4.1.164.6.1.3.71
OBJECT IDENTIFIER    

radFomiE3 1.3.6.1.4.1.164.6.1.3.72
OBJECT IDENTIFIER    

radFomiT3 1.3.6.1.4.1.164.6.1.3.73
OBJECT IDENTIFIER    

radOpt4E1C 1.3.6.1.4.1.164.6.1.3.74
OBJECT IDENTIFIER    

radOpt4T1C 1.3.6.1.4.1.164.6.1.3.75
OBJECT IDENTIFIER    

radPrbiE3 1.3.6.1.4.1.164.6.1.3.76
OBJECT IDENTIFIER    

radPrbiT3 1.3.6.1.4.1.164.6.1.3.77
OBJECT IDENTIFIER    

radHcd4Sa 1.3.6.1.4.1.164.6.1.3.78
OBJECT IDENTIFIER    

radFRmon 1.3.6.1.4.1.164.6.1.3.80
OBJECT IDENTIFIER    

radSysBRG 1.3.6.1.4.1.164.6.1.4
OBJECT IDENTIFIER    

radTRE1 1.3.6.1.4.1.164.6.1.4.1
OBJECT IDENTIFIER    

radTRE1D 1.3.6.1.4.1.164.6.1.4.2
OBJECT IDENTIFIER    

radTRE8 1.3.6.1.4.1.164.6.1.4.3
OBJECT IDENTIFIER    

radTRE8D 1.3.6.1.4.1.164.6.1.4.4
OBJECT IDENTIFIER    

radMBE1 1.3.6.1.4.1.164.6.1.4.5
OBJECT IDENTIFIER    

radMBE1D 1.3.6.1.4.1.164.6.1.4.6
OBJECT IDENTIFIER    

radMBE8 1.3.6.1.4.1.164.6.1.4.7
OBJECT IDENTIFIER    

radMBE8D 1.3.6.1.4.1.164.6.1.4.8
OBJECT IDENTIFIER    

radMLBT 1.3.6.1.4.1.164.6.1.4.9
OBJECT IDENTIFIER    

radFEB4DAS 1.3.6.1.4.1.164.6.1.4.10
OBJECT IDENTIFIER    

radTrimBrg10 1.3.6.1.4.1.164.6.1.4.11
OBJECT IDENTIFIER    

radTrimBrg16 1.3.6.1.4.1.164.6.1.4.12
OBJECT IDENTIFIER    

radRRTRE8 1.3.6.1.4.1.164.6.1.4.13
OBJECT IDENTIFIER    

radRRTRE8D 1.3.6.1.4.1.164.6.1.4.14
OBJECT IDENTIFIER    

radRRMLBT 1.3.6.1.4.1.164.6.1.4.15
OBJECT IDENTIFIER    

radRRMLBTF 1.3.6.1.4.1.164.6.1.4.16
OBJECT IDENTIFIER    

radRRTRE1D 1.3.6.1.4.1.164.6.1.4.17
OBJECT IDENTIFIER    

radTRERAS 1.3.6.1.4.1.164.6.1.4.18
OBJECT IDENTIFIER    

radTRERASa 1.3.6.1.4.1.164.6.1.4.19
OBJECT IDENTIFIER    

radMBERAS 1.3.6.1.4.1.164.6.1.4.20
OBJECT IDENTIFIER    

radMBERASa 1.3.6.1.4.1.164.6.1.4.21
OBJECT IDENTIFIER    

radFEB4FDX 1.3.6.1.4.1.164.6.1.4.22
OBJECT IDENTIFIER    

radFEB4SAS 1.3.6.1.4.1.164.6.1.4.23
OBJECT IDENTIFIER    

radRRFTBDAS 1.3.6.1.4.1.164.6.1.4.24
OBJECT IDENTIFIER    

radRRFTBSAS 1.3.6.1.4.1.164.6.1.4.25
OBJECT IDENTIFIER    

radFTBDAS 1.3.6.1.4.1.164.6.1.4.26
OBJECT IDENTIFIER    

radFTBSAS 1.3.6.1.4.1.164.6.1.4.27
OBJECT IDENTIFIER    

radFastWay100 1.3.6.1.4.1.164.6.1.4.28
OBJECT IDENTIFIER    

radSysCnvrtr 1.3.6.1.4.1.164.6.1.5
OBJECT IDENTIFIER    

radSTC1 1.3.6.1.4.1.164.6.1.5.1
OBJECT IDENTIFIER    

radSTC2 1.3.6.1.4.1.164.6.1.5.3
OBJECT IDENTIFIER    

radSTC1UDP 1.3.6.1.4.1.164.6.1.5.4
OBJECT IDENTIFIER    

radSTC2UDP 1.3.6.1.4.1.164.6.1.5.6
OBJECT IDENTIFIER    

radFTC1 1.3.6.1.4.1.164.6.1.5.10
OBJECT IDENTIFIER    

radFTC2 1.3.6.1.4.1.164.6.1.5.12
OBJECT IDENTIFIER    

radFTC1UDP 1.3.6.1.4.1.164.6.1.5.13
OBJECT IDENTIFIER    

radFTC2UDP 1.3.6.1.4.1.164.6.1.5.15
OBJECT IDENTIFIER    

radSEC1 1.3.6.1.4.1.164.6.1.5.20
OBJECT IDENTIFIER    

radSEC2 1.3.6.1.4.1.164.6.1.5.22
OBJECT IDENTIFIER    

radSEC1UDP 1.3.6.1.4.1.164.6.1.5.23
OBJECT IDENTIFIER    

radSEC2UDP 1.3.6.1.4.1.164.6.1.5.25
OBJECT IDENTIFIER    

radFEC1 1.3.6.1.4.1.164.6.1.5.30
OBJECT IDENTIFIER    

radFEC2 1.3.6.1.4.1.164.6.1.5.32
OBJECT IDENTIFIER    

radFEC1UDP 1.3.6.1.4.1.164.6.1.5.33
OBJECT IDENTIFIER    

radFEC2UDP 1.3.6.1.4.1.164.6.1.5.35
OBJECT IDENTIFIER    

radSysStkHub 1.3.6.1.4.1.164.6.1.7
OBJECT IDENTIFIER    

radRBHE 1.3.6.1.4.1.164.6.1.7.1
OBJECT IDENTIFIER    

radRBHT 1.3.6.1.4.1.164.6.1.7.2
OBJECT IDENTIFIER    

radETS4fddiDAS 1.3.6.1.4.1.164.6.1.7.3
OBJECT IDENTIFIER    

radETS4fddiSAS 1.3.6.1.4.1.164.6.1.7.4
OBJECT IDENTIFIER    

radSAHEMX 1.3.6.1.4.1.164.6.1.7.5
OBJECT IDENTIFIER    

radSAHTM 1.3.6.1.4.1.164.6.1.7.6
OBJECT IDENTIFIER    

radETS4 1.3.6.1.4.1.164.6.1.7.7
OBJECT IDENTIFIER    

radSAHEMU 1.3.6.1.4.1.164.6.1.7.8
OBJECT IDENTIFIER    

unknown 1.3.6.1.4.1.164.6.1.7.9
OBJECT IDENTIFIER    

radSAH16Eint 1.3.6.1.4.1.164.6.1.7.10
OBJECT IDENTIFIER    

radSAH16Tint 1.3.6.1.4.1.164.6.1.7.11
OBJECT IDENTIFIER    

radSAH16Eext 1.3.6.1.4.1.164.6.1.7.12
OBJECT IDENTIFIER    

radSAH16Text 1.3.6.1.4.1.164.6.1.7.13
OBJECT IDENTIFIER    

radSysPS 1.3.6.1.4.1.164.6.1.8
OBJECT IDENTIFIER    

radSPS2 1.3.6.1.4.1.164.6.1.8.1
OBJECT IDENTIFIER    

radSPS3 1.3.6.1.4.1.164.6.1.8.2
OBJECT IDENTIFIER    

radSPS6 1.3.6.1.4.1.164.6.1.8.3
OBJECT IDENTIFIER    

radSPS9 1.3.6.1.4.1.164.6.1.8.4
OBJECT IDENTIFIER    

radSPS12 1.3.6.1.4.1.164.6.1.8.5
OBJECT IDENTIFIER    

radAPD2 1.3.6.1.4.1.164.6.1.8.6
OBJECT IDENTIFIER    

radAPD8 1.3.6.1.4.1.164.6.1.8.7
OBJECT IDENTIFIER    

radAPS8 1.3.6.1.4.1.164.6.1.8.8
OBJECT IDENTIFIER    

radAPS16 1.3.6.1.4.1.164.6.1.8.9
OBJECT IDENTIFIER    

radAPS24 1.3.6.1.4.1.164.6.1.8.10
OBJECT IDENTIFIER    

radSPS3S 1.3.6.1.4.1.164.6.1.8.11
OBJECT IDENTIFIER    

radFPS8 1.3.6.1.4.1.164.6.1.8.12
OBJECT IDENTIFIER    

radFPS12 1.3.6.1.4.1.164.6.1.8.13
OBJECT IDENTIFIER    

radSPS3ScSL 1.3.6.1.4.1.164.6.1.8.14
OBJECT IDENTIFIER    

radSPS3Sc2S 1.3.6.1.4.1.164.6.1.8.15
OBJECT IDENTIFIER    

radFPS8c 1.3.6.1.4.1.164.6.1.8.16
OBJECT IDENTIFIER    

radFPS4 1.3.6.1.4.1.164.6.1.8.17
OBJECT IDENTIFIER    

radSysEth 1.3.6.1.4.1.164.6.1.9
OBJECT IDENTIFIER    

radEP8T 1.3.6.1.4.1.164.6.1.9.1
OBJECT IDENTIFIER    

radEP4TAUI 1.3.6.1.4.1.164.6.1.9.2
OBJECT IDENTIFIER    

radEP4T2FL 1.3.6.1.4.1.164.6.1.9.3
OBJECT IDENTIFIER    

radEP4TFL 1.3.6.1.4.1.164.6.1.9.4
OBJECT IDENTIFIER    

radEP4FL 1.3.6.1.4.1.164.6.1.9.5
OBJECT IDENTIFIER    

radEPR8T 1.3.6.1.4.1.164.6.1.9.7
OBJECT IDENTIFIER    

radEPR4TAUI 1.3.6.1.4.1.164.6.1.9.8
OBJECT IDENTIFIER    

radEPR4T2FL 1.3.6.1.4.1.164.6.1.9.9
OBJECT IDENTIFIER    

radEPR4TFL 1.3.6.1.4.1.164.6.1.9.10
OBJECT IDENTIFIER    

radEPR4FL 1.3.6.1.4.1.164.6.1.9.11
OBJECT IDENTIFIER    

radSysRtr 1.3.6.1.4.1.164.6.1.11
OBJECT IDENTIFIER    

radRTED 1.3.6.1.4.1.164.6.1.11.1
OBJECT IDENTIFIER    

radRTEM 1.3.6.1.4.1.164.6.1.11.2
OBJECT IDENTIFIER    

radRTEC 1.3.6.1.4.1.164.6.1.11.3
OBJECT IDENTIFIER    

radWebRanger 1.3.6.1.4.1.164.6.1.11.4
OBJECT IDENTIFIER    

radTinyRouter 1.3.6.1.4.1.164.6.1.11.5
OBJECT IDENTIFIER    

radSysAtm 1.3.6.1.4.1.164.6.1.12
OBJECT IDENTIFIER    

radStarSwitch 1.3.6.1.4.1.164.6.1.12.1
OBJECT IDENTIFIER    

radStarSwitchATM25 1.3.6.1.4.1.164.6.1.12.1.1
OBJECT IDENTIFIER    

radStarSwitchATM25L 1.3.6.1.4.1.164.6.1.12.1.2
OBJECT IDENTIFIER    

radStarSwitchATM155 1.3.6.1.4.1.164.6.1.12.1.3
OBJECT IDENTIFIER    

radAtmCsuDsu 1.3.6.1.4.1.164.6.1.12.2
OBJECT IDENTIFIER    

radAmcdE1 1.3.6.1.4.1.164.6.1.12.2.1
OBJECT IDENTIFIER    

radAmcdT1 1.3.6.1.4.1.164.6.1.12.2.2
OBJECT IDENTIFIER    

radAce20E 1.3.6.1.4.1.164.6.1.12.2.3
OBJECT IDENTIFIER    

radAce20T 1.3.6.1.4.1.164.6.1.12.2.4
OBJECT IDENTIFIER    

radAce2005 1.3.6.1.4.1.164.6.1.12.2.5
OBJECT IDENTIFIER    

radAce2002 1.3.6.1.4.1.164.6.1.12.2.6
OBJECT IDENTIFIER    

radAce2E 1.3.6.1.4.1.164.6.1.12.2.8
OBJECT IDENTIFIER    

radAce2T 1.3.6.1.4.1.164.6.1.12.2.9
OBJECT IDENTIFIER    

radAce 1.3.6.1.4.1.164.6.1.12.3
OBJECT IDENTIFIER    

radAce101 1.3.6.1.4.1.164.6.1.12.3.1
OBJECT IDENTIFIER    

radAce102 1.3.6.1.4.1.164.6.1.12.3.2
OBJECT IDENTIFIER    

agnt 1.3.6.1.4.1.164.6.2
OBJECT IDENTIFIER    

agnHwVersion 1.3.6.1.4.1.164.6.2.1
ASCII string for description and display of the agent hardware version, as it is known by the agent software.The user can update the version upon request when he changes components in the agent's module
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

agnTrapMask 1.3.6.1.4.1.164.6.2.2
The value of this attribute determines the type of traps the agent should mask and not send to the management console. The value is differently determined for different products. There are mainly two methods: - an integer number, specifying the traps' severity. - a sum of 2**n, where n is a bit assigned to a certain masked trap group. User should consult the product specification, to find out the method employed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

agnTrapValue 1.3.6.1.4.1.164.6.2.3
The value of the trap decoded in internal RAD format. Full description is given in the Trap definition file
Status: deprecated Access: read-only
OBJECT-TYPE    
  OCTET STRING  

agnChangeCnt 1.3.6.1.4.1.164.6.2.4
The number of changes in system configuration that were reported to the manager since last cold start
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

agnSpecific 1.3.6.1.4.1.164.6.2.5
Object identifier of entity containing additional information regarding this instance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

agnConfigMsg 1.3.6.1.4.1.164.6.2.6
Full configuration message coded in internal RAD application format. This entry describes agent's configuration. For MP-2200 R3, this object describes agent's support of the V5.1 feature: 1 octet ; bit 0 (LSB). '1' - V5.1 feature is supported '0' - V5.1 feature is not supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

mngTrapIpTable 1.3.6.1.4.1.164.6.2.7
This table indicates the destination address of the traps. Internally it will be limited to ten addresses.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MngEntry

mngEntry 1.3.6.1.4.1.164.6.2.7.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MngEntry  

mngID 1.3.6.1.4.1.164.6.2.7.1.1
This value indicates an index of a specific IP address
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mngIP 1.3.6.1.4.1.164.6.2.7.1.2
This value indicates the destination address of the traps. IP 0.0.0.0 removes the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

mngIPMask 1.3.6.1.4.1.164.6.2.7.1.3
This value indicates the mask of the destination addresses of the traps.
Status: deprecated Access: read-write
OBJECT-TYPE    
  IpAddress  

mngTrapMask 1.3.6.1.4.1.164.6.2.7.1.4
The value of this attribute determines the type of traps the agent should mask and not send to this NMS. The value is differently determined for different products. There are mainly two methods: - an integer number, specifying the traps' severity. - a sum of 2**n, where n is a bit assigned to a certain masked trap group. User should consult the product specification, to find out the method employed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

agnIndication 1.3.6.1.4.1.164.6.2.8
Attribute describing the state of the entity the agent is responsible for. In case of a modular entity, the value of this attribute will be according to the component which is in the worst state. The order of severity (from top to bottom) is: faulty (critical)-> major-> minor-> warning-> event-> normal (off).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER faulty(1), warning(2), normal(3), minor(4), major(5), event(6)  

agnMonitorModeCmd 1.3.6.1.4.1.164.6.2.9
Setting this attribute to ON, will enforce the agent to change its mode of operation to Monitor Mode
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3)  

agnLed 1.3.6.1.4.1.164.6.2.10
This entry specifies the LEDs status of the agent module . Each led will be represented by 4 bits where the first 2 bits (left) will specify the status : (00=NA, 01=OFF, 10=ON, 11=BLINK), and the next two bits (right) will specify the color : (00=GREEN, 01=RED, 10=YELLOW, 11=ORANGE)
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

trapTable 1.3.6.1.4.1.164.6.2.11
This table includes the last few traps generated by the agent, for future retrieval. The table has a limited capacity. If traps are not retrieved in proper time, they will be over-written by new traps
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TrapEntry

trapEntry 1.3.6.1.4.1.164.6.2.11.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  TrapEntry  

trapID 1.3.6.1.4.1.164.6.2.11.1.1
This value indicates an index of a specific trap
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trapVal 1.3.6.1.4.1.164.6.2.11.1.2
This value is the actual ASCII description of the trap.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

trapTimeSinceOccurrence 1.3.6.1.4.1.164.6.2.11.1.3
This value indicates the amount of time passed since the occurrence of the event that trigger this trap.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

fileTransfer 1.3.6.1.4.1.164.6.2.12
OBJECT IDENTIFIER    

fileServerIP 1.3.6.1.4.1.164.6.2.12.1
The IP address of the server from which the file is loaded
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

fileName 1.3.6.1.4.1.164.6.2.12.2
The name of the file to be loaded. For protection, read returns NULL.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

fileTransCmd 1.3.6.1.4.1.164.6.2.12.3
The command to be executed on fileName at fileServerIP.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER swDwnLoad(1), configDwnLoad(2), configUpLoad(3), coProcDwnLoad(4), stateUpLoad(5), dwnLoadUserFile(6), upLoadUserFile(7), noOp(255)  

tftpRetryTimeOut 1.3.6.1.4.1.164.6.2.12.4
General Retransmission time-out value (seconds)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

tftpTotalTimeOut 1.3.6.1.4.1.164.6.2.12.5
Total Retransmission time-out value (seconds)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

tftpStatus 1.3.6.1.4.1.164.6.2.12.6
Status of tftp session. When a session ended with success, the tftpStatus should be endedOk(6). Before restarting a tftp session, the NMS should set the tftpStatus to noOp(2). That's the reason of ACCESS read-write to this field.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noOp(2), connecting(3), transferringData(4), endedTimeOut(5), endedOk(6), error(7)  

tftpError 1.3.6.1.4.1.164.6.2.12.7
The MSB represents the standard error code. The LSB represents the private error code. 0x0000 is No Error 0x0100 is File Not Found 0x0400 is Illegal TFTP operation 0x0500 is Unknown transfer ID 0x0001 is Server Overflow 0x0002 is No empty UDP port 0x0003 is No empty connection 0x0004 is Illegal File Mode 0x0007 is Illegal PDU size
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(2)  

fileTransferToSubSystems 1.3.6.1.4.1.164.6.2.12.8
This object represents the sub-systems the fileTransCmd refers to. It should be used when a system is divided to sub-systems and each sub-system (or part of them) can have a different SW/Configuration. Each bit of this object will represent one of the sub-systems. Bit='1' - APPLY to respective sub-system Bit='0' - DO NOT APPLY to respective sub-system For the meaning of each bit, see product's specification. User will select the sub-systems envolved by filling-in the bits that represent these sub-systems. In this case, the file represented by 'fileName' will include several parts, each representing one of the sub-systems. The agent will refer only to the part/s indicated by this object. 0 Octet Strings = not applicable DEFVAL = 0h for the products that support this object.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

fileNameWithinProduct 1.3.6.1.4.1.164.6.2.12.9
The file name used by the product within the product file system.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

systemReset 1.3.6.1.4.1.164.6.2.13
Reset action to be performed on the system.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3), resetConfig(4)  

systemTiming 1.3.6.1.4.1.164.6.2.14
OBJECT IDENTIFIER    

systemDate 1.3.6.1.4.1.164.6.2.14.1
System date.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

systemTime 1.3.6.1.4.1.164.6.2.14.2
System time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

systemPort 1.3.6.1.4.1.164.6.2.15
OBJECT IDENTIFIER    

physicalConnectorTable 1.3.6.1.4.1.164.6.2.15.1
This table includes the connector type of ports or interfaces.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PhysicalConnectorEntry

physicalConnectorEntry 1.3.6.1.4.1.164.6.2.15.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PhysicalConnectorEntry  

portIdx 1.3.6.1.4.1.164.6.2.15.1.1.1
This object is an index of the specific port or interface. For a port, the index will be as agreed between agent and application. For an interface, ifIndex may be used.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

physicalConnector 1.3.6.1.4.1.164.6.2.15.1.1.2
The connector of the port/interface. other - none of the specified connectors none - no connector.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), v35(2), rs530(3), x21(4), bnc(5), utp(6), aui(7), rs422(8), crossUtp(9), rj45(10), v24(11), g703(12), termBlock3AndRj45(13), terminalBlock3(14), terminalBlock5(15), terminalBlock7(16), db25(17), db15(18), rj45ethernet(19), termBlock5AndRj45(20), db9(21), g703E1(22), g703E1-LTU(23), sc(24), st(25), stl(26), fc(27), tb5w(28), termBlock6AndRj45(29), ethBnc(30), scsi26(31), eth4381(32), twoBnc(33), scsi50(34), twoMiniBnc(35), sf1(36), terminalBlock4(37), sf2(38), v36(40), block4W(41), none(255)  

portOptWaveLength 1.3.6.1.4.1.164.6.2.15.1.1.3
Wave Length of an Optical interface/port in [nm] and specification if Laser or not. notApplicable - for non-optical ports.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), nm850(2), nm1300(3), nm1300Laser(4), nm1550Laser(5)  

prtSupervisory 1.3.6.1.4.1.164.6.2.15.2
OBJECT IDENTIFIER    

prtSpTable 1.3.6.1.4.1.164.6.2.15.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtSpEntry

prtSpEntry 1.3.6.1.4.1.164.6.2.15.2.1.1
Supervisory port parameter table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtSpEntry  

prtSupervisoryIndex 1.3.6.1.4.1.164.6.2.15.2.1.1.1
The SP port index. The LS byte of the integer is the port index 1..255. The MS byte is different than 0 only if the port belongs to a module. In that case it is the module number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtSupervisoryRate 1.3.6.1.4.1.164.6.2.15.2.1.1.2
This attribute indicates the operation rate (speed) of the port. auto - automatic rate selection, by the agent.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), s300bps(2), s1200bps(3), s2400bps(4), s4800bps(5), s9600bps(6), s19200bps(7), s38400bps(8), s57600bps(9), s115200bps(10)  

prtSupervisoryDataBits 1.3.6.1.4.1.164.6.2.15.2.1.1.3
This attribute indicates the number of data bits in an async frame
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dataBits7(1), dataBits8(2)  

prtSupervisoryParity 1.3.6.1.4.1.164.6.2.15.2.1.1.4
This attribute indicates the parity mode in an async frame
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), odd(2), even(3)  

prtSupervisoryStopBits 1.3.6.1.4.1.164.6.2.15.2.1.1.5
This attribute indicates the parity mode in an async frame.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), stopBits1(2), stopBits1dot5(3), stopBits2(4)  

prtSupervisoryUsage 1.3.6.1.4.1.164.6.2.15.2.1.1.6
This attribute indicates the usage of the SP port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), noUse(2), terminal(3), nmsSlip(4), nmsPpp(5), muxSlip(6), muxPpp(7), dialOut(8)  

prtSupervisoryInterface 1.3.6.1.4.1.164.6.2.15.2.1.1.7
This attribute indicates the supervisory port interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), dce(2), dte(3)  

prtSupervisoryCTS 1.3.6.1.4.1.164.6.2.15.2.1.1.8
CTS line state.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), on(2), rts(3), dteWait(4), dteIgnore(5)  

prtSupervisoryDcdDelay 1.3.6.1.4.1.164.6.2.15.2.1.1.9
DCD delay in msec.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), d0(2), d10(3), d50(4), d100(5), d200(6), d300(7)  

prtSupervisoryDSR 1.3.6.1.4.1.164.6.2.15.2.1.1.10
DSR line state.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), on(2), dtr(3)  

prtSupervisoryRoutProtocol 1.3.6.1.4.1.164.6.2.15.2.1.1.11
This attribute indicates the routing protocol of the port. notApplicable - for DP.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), proprietary(3), rip2(4)  

prtPerformance 1.3.6.1.4.1.164.6.2.15.3
OBJECT IDENTIFIER    

prtPerfTable 1.3.6.1.4.1.164.6.2.15.3.1
This table includes G.826 ports or interfaces.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtPerfEntry

prtPerfEntry 1.3.6.1.4.1.164.6.2.15.3.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtPerfEntry  

prtPerfIdx 1.3.6.1.4.1.164.6.2.15.3.1.1.1
This object is an index of the specific port or interface. For a port, the index will be as agreed between agent and application. For an interface, ifIndex may be used.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtPerfPeriodRef 1.3.6.1.4.1.164.6.2.15.3.1.1.2
This object is an index that specifies which period of time, the next 5 objects refer to. currentPeriod - the period since last prtPerfSaveAndResetCmd received or since Start-up (if no prtPerfSaveAndResetCmd was received since Start-up) until now. lastPeriod - the period between last two commands of prtPerfSaveAndResetCmd. - If only one command occured since Start-up: the period between Start-up and last command. - If no command occured since Start-up: this period will not actually exist. In this case, he following 5 objects will be 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER currentPeriod(1), lastPeriod(2)  

prtPerfElapsedTime 1.3.6.1.4.1.164.6.2.15.3.1.1.3
Elapsed Time in seconds. - for prtPerfPeriodRef=currentPeriod: The period since last prtPerfSaveAndResetCmd received or since Start-up (if no prtPerfSaveAndResetCmd was received since Start-up) until now. - for prtPerfPeriodRef=lastPeriod: The value of prtPerfElapsedTime when last prtPerfSaveAndResetCmd was received.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtPerfUAS 1.3.6.1.4.1.164.6.2.15.3.1.1.4
Number of Unavailable Seconds for the reference period (prtPerfPeriodRef).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtPerfES 1.3.6.1.4.1.164.6.2.15.3.1.1.5
Number of Errored Seconds for the reference period (prtPerfPeriodRef).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtPerfSES 1.3.6.1.4.1.164.6.2.15.3.1.1.6
Number of Severely Errored Seconds for the reference period (prtPerfPeriodRef).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtPerfBBE 1.3.6.1.4.1.164.6.2.15.3.1.1.7
Number of Background Block (or Frame) Errors for the reference period (prtPerfPeriodRef).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtPerfBlocksPerSec 1.3.6.1.4.1.164.6.2.15.3.1.1.8
Blocks per second (or frames per second) of the port/interface indicated by portIdx. This object is constant for a certain port/interface. It is not affected by the prtPerfPeriodRef index.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtPerfTimeTag 1.3.6.1.4.1.164.6.2.15.3.1.1.9
Time Tag of Last Period: sysUpTime when last prtPerfSaveAndResetCmd was executed. This object is applicable only for prtPerfPeriodRef=lastPeriod. For prtPerfPeriodRef=currentPeriod, the value will always be 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

prtPerfSaveAndResetCmd 1.3.6.1.4.1.164.6.2.15.3.1.1.10
A command per port/interface, to Save data of Current Period in Last Period data-set and start a new counting period for Current Period. This object is applicable only for prtPerfPeriodRef=currentPeriod. Setting this object to on(3) for prtPerfPeriodRef=last, will cause the agent to return: Bad Value response. When setting validly this object to on(3), agent will perform the required command and will reset automatically the value of this object to off(2). Setting this object to off(2), will do nothing.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtTest 1.3.6.1.4.1.164.6.2.15.4
OBJECT IDENTIFIER    

prtTestTable 1.3.6.1.4.1.164.6.2.15.4.1
This table includes test data for ports or interfaces.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtTestEntry

prtTestEntry 1.3.6.1.4.1.164.6.2.15.4.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtTestEntry  

prtTestIdx 1.3.6.1.4.1.164.6.2.15.4.1.1.1
This object is an index of the specific port or interface. For a port, the index will be as agreed between agent and application. For an interface, ifIndex may be used.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtTestCmdAndStatus 1.3.6.1.4.1.164.6.2.15.4.1.1.2
Setting this object to a value as detailed furter on (except 0) will initiate a test on the specific port. The test/s requested will be set according to the respective bit. The value of this object will be a sum of (2**n), where n is the Bit: TEST BIT VALUE ----------- --- ------ reserved 0 1 PayloadLoop=RLB 1 (=Remote Loopback) 2 LineLoop=DIG 2 (=Digital) 4 OtherLoop 3 8 InwardLoop=LLB 4 (=Local Loopback) 16 BERT 5 32 LC 6 64 e.g : If the requested value is 20 -> 010100 -> Bits 2 & 4 are set -> the requested tests are : LineLoopback=DIG InwardLoopback=LLB Not all tests combinations are valid. For valid test combination, see each product's specification. The terminology and order of tests (except BERT) is according to the one used for Test Status of DS1 and DS3 standards. Setting this object to stop (value=0 ; all bits are 0), will stop all the user requested tests running on the selected port. When no test is running on the port, the Get value (test status) will be 0. PayloadLoop=RLB The received signal at this interface is looped through the device. Typically the received signal is looped back for retransmission after it has passed through the device's framing function. LineLoop=DIG The received signal at this interface does not go through the device (minimum penetration) but is looped back out. OtherLoop Loopbacks that are not defined here. InwardLoop=LLB The sent signal at this interface is looped back through the device. LC This loop is applicable only for HSSI interface, towards the router .
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

prtBertCounter 1.3.6.1.4.1.164.6.2.15.4.1.1.3
This object indicates the number of BERT errors encountered during the BERT operation. It is valid only when BERT (Bit Error Rate Test) is active on the specific port. The Counter starts from zero (0) anytime BERT is initiated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtTestInitiator 1.3.6.1.4.1.164.6.2.15.4.1.1.4
This object indicates who initiated this port's test/s.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), user(2), remoteUnit(3), dteRouter(4)  

prtParam 1.3.6.1.4.1.164.6.2.15.5
OBJECT IDENTIFIER    

prtParamTable 1.3.6.1.4.1.164.6.2.15.5.1
This table includes the connector type of ports or interfaces.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtParamEntry

prtParamEntry 1.3.6.1.4.1.164.6.2.15.5.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtParamEntry  

prtParamIdx 1.3.6.1.4.1.164.6.2.15.5.1.1.1
This object is an index of the specific port or interface. For a port, the index will be as agreed between agent and application. For an interface, ifIndex may be used.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtControlCnfg 1.3.6.1.4.1.164.6.2.15.5.1.1.2
This object may be used for port RW general parameter/s. For detailed meaning, see product's spec. Supported by: PRBi-E3/T3.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

systemResetAllStatsCmd 1.3.6.1.4.1.164.6.2.16
Reset statistics of all ports and connections of the device.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

systemClearTablesCmd 1.3.6.1.4.1.164.6.2.17
tempCnfgTables - Set *RowStatus = destroy for all entries of some tables having *RowStatus object, for temporary configuration only! (255). For the relevant tables, see product's specification. This object should be used by WAN product applications before performing the Update operation, in order to clear old entries of these tables. off - agent will automatically change to this value, after performing the command.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(2), tempCnfgTables(3)  

systemParameter 1.3.6.1.4.1.164.6.2.18
This parameter can be used for different purposes: - TELNET session time-out in seconds. - Ace20: when trying to create row in a table that already has row with the same values, if set of values has to be uniqe in table, this attribute is set to the index of the existing row.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

agnGlobalAlarmMask 1.3.6.1.4.1.164.6.2.19
The value of this attribute determines the alarm traps the agent should mask and not send to the managers. Each bit from a certain octet represents a certain alarm.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

alarmSeverity 1.3.6.1.4.1.164.6.2.20
This object specifies the severity of the alarms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER event(3), minor(4), major(5), warning(6), critical(7)  

alarmState 1.3.6.1.4.1.164.6.2.21
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

agnTestStatus 1.3.6.1.4.1.164.6.2.22
Indicates the current test status (for all levels: system, card, port). This attribute will be set to: on(3): when there is at least one test in progress on the system/card/port off(2): when there is NO test in progress on the system/card/port
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

systemSaveAndResetAllStatsCmd 1.3.6.1.4.1.164.6.2.23
on - a command to Save data of Current Period in Last Period data-set and start a new counting period for Current Period. off - agent will automatically change to this value, after performing the command.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

systemDefaultGateway 1.3.6.1.4.1.164.6.2.24
Default Gateway's IP Address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

systemPsTable 1.3.6.1.4.1.164.6.2.25
This table describes the PS types of a device. Usage of this table is specified in the device's NMS SRS
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SystemPsEntry

systemPsEntry 1.3.6.1.4.1.164.6.2.25.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SystemPsEntry  

systemPsIndex1 1.3.6.1.4.1.164.6.2.25.1.1
First Index. In HUBs: 1 = PS-A slot 2 = PS-B slot. In SA units: 1 = PS1 2 = PS2 Default = 1
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

systemPsIndex2 1.3.6.1.4.1.164.6.2.25.1.2
Second Index. In HUBs: 1 always. In SA units: 1 = Local 2 = Remote Default = 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

systemPsType 1.3.6.1.4.1.164.6.2.25.1.3
The type of PS, for a stand-alone product. acDc - AC with rj45 DC.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), ac(2), dc(3), acDc(4)  

tftpStatusChangeTrap 1
This trap is sent whenever the status of tftp changed.
TRAP-TYPE    

agnStatusChangeTrap 2
This trap is sent whenever the state of the entity the agent is responsible for changed. TDM devices will send agnTestStatus variable to indicate the current test status.
TRAP-TYPE    

prtStatusChangeTrap 3
This trap is sent whenever the state of a port changed. Attached, will be parameter/s that indicate the new port status. The attached variables will be specified in the specifications of the products supporting this trap.
TRAP-TYPE    

wanGen 1.3.6.1.4.1.164.3.1
OBJECT IDENTIFIER    

muxHub 1.3.6.1.4.1.164.3.2
OBJECT IDENTIFIER    

chasWanGen 1.3.6.1.4.1.164.3.1.1
OBJECT IDENTIFIER    

agnWanGen 1.3.6.1.4.1.164.3.1.2
OBJECT IDENTIFIER    

mdlWanGen 1.3.6.1.4.1.164.3.1.3
OBJECT IDENTIFIER    

prtWanGen 1.3.6.1.4.1.164.3.1.4
OBJECT IDENTIFIER    

mapWanGen 1.3.6.1.4.1.164.3.1.5
OBJECT IDENTIFIER    

diverseIfWanGen 1.3.6.1.4.1.164.3.1.6
OBJECT IDENTIFIER    

statAgnGen 1.3.6.1.4.1.164.3.1.2.1
OBJECT IDENTIFIER    

cnfgAgnGen 1.3.6.1.4.1.164.3.1.2.2
OBJECT IDENTIFIER    

cmprAgnGen 1.3.6.1.4.1.164.3.1.2.3
OBJECT IDENTIFIER    

alrBuffGen 1.3.6.1.4.1.164.3.1.2.4
OBJECT IDENTIFIER    

agnFlipDb 1.3.6.1.4.1.164.3.1.2.5
OBJECT IDENTIFIER    

agnSa 1.3.6.1.4.1.164.3.1.2.6
OBJECT IDENTIFIER    

agnListDecoding 1.3.6.1.4.1.164.3.1.2.7
OBJECT IDENTIFIER    

agnSystemDlci 1.3.6.1.4.1.164.3.1.2.8
OBJECT IDENTIFIER    

agnVoiceSwitching 1.3.6.1.4.1.164.3.1.2.9
OBJECT IDENTIFIER    

agnSigProfile 1.3.6.1.4.1.164.3.1.2.10
OBJECT IDENTIFIER    

agnSystemTs 1.3.6.1.4.1.164.3.1.2.11
OBJECT IDENTIFIER    

statMdlGen 1.3.6.1.4.1.164.3.1.3.1
OBJECT IDENTIFIER    

cnfgMdlGen 1.3.6.1.4.1.164.3.1.3.2
OBJECT IDENTIFIER    

cmprMdlGen 1.3.6.1.4.1.164.3.1.3.3
OBJECT IDENTIFIER    

statPrtGen 1.3.6.1.4.1.164.3.1.4.1
OBJECT IDENTIFIER    

cnfgPrtGen 1.3.6.1.4.1.164.3.1.4.2
OBJECT IDENTIFIER    

cmprPrtGen 1.3.6.1.4.1.164.3.1.4.3
OBJECT IDENTIFIER    

agnMux 1.3.6.1.4.1.164.3.2.1
OBJECT IDENTIFIER    

mdlMux 1.3.6.1.4.1.164.3.2.2
OBJECT IDENTIFIER    

prtMux 1.3.6.1.4.1.164.3.2.3
OBJECT IDENTIFIER    

statPrtMux 1.3.6.1.4.1.164.3.2.3.1
OBJECT IDENTIFIER    

cnfgPrtMux 1.3.6.1.4.1.164.3.2.3.2
OBJECT IDENTIFIER    

prtClCnfg 1.3.6.1.4.1.164.3.2.3.2.1
OBJECT IDENTIFIER    

prtPh1MlCnfg 1.3.6.1.4.1.164.3.2.3.2.2
OBJECT IDENTIFIER    

prtPhPlCnfg 1.3.6.1.4.1.164.3.2.3.2.3
OBJECT IDENTIFIER    

prtLs2Cnfg 1.3.6.1.4.1.164.3.2.3.2.4
OBJECT IDENTIFIER    

prtHs4Cnfg 1.3.6.1.4.1.164.3.2.3.2.7
OBJECT IDENTIFIER    

prtHsiCnfg 1.3.6.1.4.1.164.3.2.3.2.8
OBJECT IDENTIFIER    

prtPVc4Cnfg 1.3.6.1.4.1.164.3.2.3.2.9
OBJECT IDENTIFIER    

prtHsrCnfg 1.3.6.1.4.1.164.3.2.3.2.10
OBJECT IDENTIFIER    

prtMbeCnfg 1.3.6.1.4.1.164.3.2.3.2.11
OBJECT IDENTIFIER    

prtTreCnfg 1.3.6.1.4.1.164.3.2.3.2.12
OBJECT IDENTIFIER    

prtLs6Cnfg 1.3.6.1.4.1.164.3.2.3.2.13
OBJECT IDENTIFIER    

prtVc3Cnfg 1.3.6.1.4.1.164.3.2.3.2.14
OBJECT IDENTIFIER    

prtVcPbxCnfg 1.3.6.1.4.1.164.3.2.3.2.15
OBJECT IDENTIFIER    

prtIsdnCnfg 1.3.6.1.4.1.164.3.2.3.2.16
OBJECT IDENTIFIER    

prtLogicalCnfg 1.3.6.1.4.1.164.3.2.3.2.17
OBJECT IDENTIFIER    

prtFrPlusCnfg 1.3.6.1.4.1.164.3.2.3.2.18
OBJECT IDENTIFIER    

prtMl4Cnfg 1.3.6.1.4.1.164.3.2.3.2.19
OBJECT IDENTIFIER    

prtAcmCnfg 1.3.6.1.4.1.164.3.2.3.2.20
OBJECT IDENTIFIER    

chasVersion 1.3.6.1.4.1.164.3.1.1.1
An ASCII string for description and display of the agent chassis version.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

chasTotalNoOfSlt 1.3.6.1.4.1.164.3.1.1.2
This entry indicates the number of physical slots in the chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chasTotalNoOfIoSlt 1.3.6.1.4.1.164.3.1.1.3
This entry indicates the total number of physical IO slots in the chassis, (not all slots hardware should be occupied and active) .
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chasTotalNoOfPsSlt 1.3.6.1.4.1.164.3.1.1.4
This entry indicates the number of physical Power Supply slots in the chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chasTotalNoOfClSlt 1.3.6.1.4.1.164.3.1.1.5
This entry indicates the number of physical Common Logic slots in the chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnSDateFormat 1.3.6.1.4.1.164.3.1.2.1.1
This entry indicates the date and time format used for the agnSDateAndTimeCmd and for the alarm history report. MP-2100H, MP-2100 r1-r4 and MAXcess products do not support the 'yyyyMMDD' format.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ddMMYYYY(1), mmDDYYYY(2), yyyyDDMM(3), yyyyMMDD(4)  

agnSDateCmd 1.3.6.1.4.1.164.3.1.2.1.2
This entry indicates the current date as it is known by the agent using its own real-time clock. The format would be as specified by the agnSDateFormat. This parameter can be set for time synchronization between the NMS and the Agent.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..255)  

agnSTimeCmd 1.3.6.1.4.1.164.3.1.2.1.3
This entry indicates the current time as it is known by the agent using its own real-time clock. This parameter can be set for time synchronization between the NMS and the Agent.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..255)  

agnSActiveCnfg 1.3.6.1.4.1.164.3.1.2.1.4
This entry specifies the unique identifier of the configuration, that is currently active and running.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnSEditCnfg 1.3.6.1.4.1.164.3.1.2.1.5
This entry indicates the unique identifier of the configuration that is currently loaded into the tmp working space for manipulation and update operations. Value of 255 means no config. is under editing process.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnSLastCnfgFlipTime 1.3.6.1.4.1.164.3.1.2.1.6
This entry indicates the Date & Time of the last flip to the current configuration at the agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

agnSLastCnfgFlipCause 1.3.6.1.4.1.164.3.1.2.1.7
This entry describes the flip's cause.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

agnSEditBy 1.3.6.1.4.1.164.3.1.2.1.8
This entry indicates which MMI application is working on the edited config. The editing phase starts at the first modify operation and ends after an update(load) operation.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), snmp(2), terCon1(3), terCon2(4), terInbandCon1(5), terInbandCon2(6), lcd(7)  

agnSClkSrc 1.3.6.1.4.1.164.3.1.2.1.9
This entry indicates the source of the system clock.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER master(1), fallback(2), internal(3)  

agnSAlrStatus 1.3.6.1.4.1.164.3.1.2.1.10
Indicates the alarm state in the agent level, i.e. lower level (card/port) alarms not included. critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(2), event(3), minor(4), major(5), warning(6), critical(7)  

agnSAlrStatusAll 1.3.6.1.4.1.164.3.1.2.1.11
Indicates the alarm state of the entire agent, i.e. including card and port alarms status. critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(2), event(3), minor(4), major(5), warning(6), critical(7)  

agnSMaskedAlrStat 1.3.6.1.4.1.164.3.1.2.1.12
Indicates the alarm state in the agent level,[ i.e. lower level (card/port) alarms not included] including Masked alarms. critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(2), event(3), minor(4), major(5), warning(6), critical(7)  

agnSMaskedAlrStatAll 1.3.6.1.4.1.164.3.1.2.1.13
Indicates the alarm state of the entire agent, i.e. including card and port alarms status,including Masked alarms. critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(2), event(3), minor(4), major(5), warning(6), critical(7)  

agnSTstStatAll 1.3.6.1.4.1.164.3.1.2.1.14
on(3) - when there is at least one test in progress in one of the agent cards, otherwise the value will be off(2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

agnSAlrTable 1.3.6.1.4.1.164.3.1.2.1.15
List of agent related alarms and indications for alarms at system level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnSAlrEntry

agnSAlrEntry 1.3.6.1.4.1.164.3.1.2.1.15.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AgnSAlrEntry  

agnSAlrIdx 1.3.6.1.4.1.164.3.1.2.1.15.1.1
A unique number to identify an entry in the alarm status table of the agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnSAlrCodeDescription 1.3.6.1.4.1.164.3.1.2.1.15.1.2
This attribute is a full text description of the alarm . The alarm description includes the following information: alarm code, alarm text, alarm severity, Masked or Inverted flag and counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

agnSAlrCode 1.3.6.1.4.1.164.3.1.2.1.15.1.3
A code identifying the alarm of an entry in the alarm status table at system level.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnSAlrSeverity 1.3.6.1.4.1.164.3.1.2.1.15.1.4
The severity of the alarm.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER event(3), minor(4), major(5), warning(6), critical(7)  

agnSAlrState 1.3.6.1.4.1.164.3.1.2.1.15.1.5
State of the alarm.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

agnSAlrCounter 1.3.6.1.4.1.164.3.1.2.1.15.1.6
A counter - how many times the alarm occured since last clear operation. ON and OFF Alarm will be counted separately.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnSAlrMask 1.3.6.1.4.1.164.3.1.2.1.15.1.7
Alarm mask : on/off.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

agnSAlrInvert 1.3.6.1.4.1.164.3.1.2.1.15.1.8
Alarm invert : on/off.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

agnSClearAlrCmd 1.3.6.1.4.1.164.3.1.2.1.16
Setting this attribute to ON, enforce a clear operation on all the agent(general) events. General alarms are alarms which are not specific to a card or port. The clear operation will not be applied for masked/inverted alarms.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

agnSClearAllAlrCmd 1.3.6.1.4.1.164.3.1.2.1.17
Setting this attribute to ON, enforce a clear operation on all MUX alarm events at the levels of agent, slots and ports. The clear operation will not be applied for masked/inverted alarms.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

agnSSanityCheckStatus 1.3.6.1.4.1.164.3.1.2.1.18
Upon completion of the Sanity check process on the TmpCnfg this attribute will be set to: FAIL(2) - when there is at least one error encountered and possibly some warnings. WARNING(3) - when there are only warnings. otherwise, the value will be OK(4). The value will be UNKNOWN(1) if changes were made in the TmpCnfg following the last Sanity check.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), fail(2), warning(3), ok(4)  

agnSNoOfSanityCheckErr 1.3.6.1.4.1.164.3.1.2.1.19
This entry indicates the number of errors/warnings discovered by the last SanityCheck process.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnSErrListTable 1.3.6.1.4.1.164.3.1.2.1.20
List of errors and warnings found during Sanity Check process.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnSErrListEntry

agnSErrListEntry 1.3.6.1.4.1.164.3.1.2.1.20.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AgnSErrListEntry  

agnSErrIdx 1.3.6.1.4.1.164.3.1.2.1.20.1.1
Unique number to identify an entry in the error list table. The maximum entry value cannot exceed the value of 'agnSNoOfSanityCheckErr'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnSErrDescription 1.3.6.1.4.1.164.3.1.2.1.20.1.2
This attribute is a full text description of the sanity check error including error code, slot and port numbers related to the code .
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

agnSMaxNoOfCnfg 1.3.6.1.4.1.164.3.1.2.1.21
Maximum number of configurations that can be defined and stored in the MUX. If the mux has a large capacity, the maximum will be limited to 254.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnSCnfgTable 1.3.6.1.4.1.164.3.1.2.1.22
This table contains an entry per configuration. It indicates if the configuration is valid.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnSCnfgEntry

agnSCnfgEntry 1.3.6.1.4.1.164.3.1.2.1.22.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AgnSCnfgEntry  

agnSEntryIdx 1.3.6.1.4.1.164.3.1.2.1.22.1.1
Unique number to identify an entry in the configuration table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnSEntryIsValid 1.3.6.1.4.1.164.3.1.2.1.22.1.2
This attribute indicates whether the specific configuration is valid in the MUX . Value of NO indicates: no such configuration in the MUX.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

agnCSanityCheckCmd 1.3.6.1.4.1.164.3.1.2.2.1
Setting this attribute to on(3) will initiate the process of Sanity check on the TmpCnfg. Upon completion the value will automatically be changed to off(2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

agnCSaveCnfgIdxCmd 1.3.6.1.4.1.164.3.1.2.2.2
This attribute specifies the Id of the target RealCnfg to which the TmpCnfg should be transferred. Upon set command the MUX will initiate the Sanity-Check process first. If successful, the actual transfer will be performed. If warnings are detected, the user will have to perform the command again to confirm the operation. Setting this object a second time to the same value without performing any change in the database, will cause the result: agnSSanityCheckStatus = unknown
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..100  

agnCLoadCnfgIdxCmd 1.3.6.1.4.1.164.3.1.2.2.3
This attribute specifies the Id of the source Cnfg to be loaded into the TmpCnfg. Upon set operation the actual transfer will be initiated. The operation is valid only on Valid configurations (agnSEntryIsValid)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..100  

agnCClkSrcTable 1.3.6.1.4.1.164.3.1.2.2.4
All the entries of this table are identical (have the same value) for all the configurations (1..100) except the TmpCnfg. The write operation into the Table Objects is valid only for the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnCClkSrcEntry

agnCClkSrcEntry 1.3.6.1.4.1.164.3.1.2.2.4.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AgnCClkSrcEntry  

agnCClkCnfgIdx 1.3.6.1.4.1.164.3.1.2.2.4.1.1
This attribute indicates the Idx of the Cnfg(1..100) being accessed and Idx 255 relates to the TmpCnfg.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

agnCClkSrcIdx 1.3.6.1.4.1.164.3.1.2.2.4.1.2
An index to the table. There are only two entries to this table. Index 1 points to the Master clock parameters and Index 2 points to the Fallback clock parameters
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

agnCClkSrcMode 1.3.6.1.4.1.164.3.1.2.2.4.1.3
The source of the nodal timing.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER internal(1), rxClk(2)  

agnCClkSrcSlt 1.3.6.1.4.1.164.3.1.2.2.4.1.4
This entry is valid only when we are working in rxClk mode. For an invalid entry, the return value will be '7fff'h.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

agnCClkSrcPrt 1.3.6.1.4.1.164.3.1.2.2.4.1.5
This entry is valid only when we are working in rxClk mode. For an invalid entry, the return value will be '7fff'h.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), exPrt9(9), exPrt10(10), exPrt11(11), exPrt12(12), notApplicable(100)  

agnCDeleteCnfgIdxCmd 1.3.6.1.4.1.164.3.1.2.2.5
Setting this attribute will delete the requested DB from the NVRAM .
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..100  

agnCDefaultCnfgIdxCmd 1.3.6.1.4.1.164.3.1.2.2.6
Setting this attribute will define the desired working configuration when no conditions of the Flip DB Table are fulfilled and no Net GO command was issued. This command will be accepted only if the Configuration number exists (agnSEntryIsValid=yes).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..100  

agnCnfgDataTable 1.3.6.1.4.1.164.3.1.2.2.7
This table contains data about the agent configurations. The table will support only data about valid configurations of the agent.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnCnfgDataEntry

agnCnfgDataEntry 1.3.6.1.4.1.164.3.1.2.2.7.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AgnCnfgDataEntry  

agnCnfgIdx 1.3.6.1.4.1.164.3.1.2.2.7.1.1
This object indicates the Idx of the agent' Cnfg the following objects refer. 255=Temporary Cnfg (Set is done only to this configuration).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

agnCnfgDesc 1.3.6.1.4.1.164.3.1.2.2.7.1.2
This object is a description of the Configuration, entered by user, to enhance Cnfg recognition.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..30)  

agnCnfgUpdDate 1.3.6.1.4.1.164.3.1.2.2.7.1.3
This object indicates the date when last update of this configuration was performed, as it is known by the agent using its own real-time clock. The format would be as specified by the agnSDateFormat. When update is performed, the agent should save the date.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

agnCnfgUpdTime 1.3.6.1.4.1.164.3.1.2.2.7.1.4
This object indicates the time when last update of this configuration was performed, as it is known by the agent using its own real-time clock. When update is performed, the agent should save the time.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

agnCnfgUpdMnger 1.3.6.1.4.1.164.3.1.2.2.7.1.5
This object indicates the IP Address of the Manager who performed the last update of this configuration. When update is performed, the agent should save the IP Address of the Manager who commanded the update. That will enable a manager to know if he performed the last update, or another manager did.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

agnCnfgAlarm 1.3.6.1.4.1.164.3.1.2.2.8
OBJECT IDENTIFIER    

agnCnfgAlrFilterWindow 1.3.6.1.4.1.164.3.1.2.2.8.1
Window of time, in minutes. During this Window, the alarms filter is performed. Same Window for all agent alarms that need filtering. Upon end of the Window, the state of the alarm is updated and a new Window starts. If no alarm needs filtering, this object's value will not be used.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..30  

agnCnfgAlrTable 1.3.6.1.4.1.164.3.1.2.2.8.2
This table enables the user to set attributes to each alarm. Setting for a non-existing entry agnCnfgAlrMask, agnCnfgAlrInvert or agnCnfgAlrFilter to 'yes'(or yesAndSave for Mask) will add this new entry to the table. Setting for an existing entry agnCnfgAlrMask/ agnCnfgAlrInvert/agnCnfgAlrFilter (one or more) to 'no' (noAndSave for Mask) so that ALL these objects' values are 'no' , will delete this entry from the table. For agnCnfgAlrMask, only if [(last saved value=noAndSave) AND (new value is 'no' or 'noAndSave')] the object's value is considered 'no' for deleting the entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnCnfgAlrEntry

agnCnfgAlrEntry 1.3.6.1.4.1.164.3.1.2.2.8.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AgnCnfgAlrEntry  

agnCnfgAlrCode 1.3.6.1.4.1.164.3.1.2.2.8.2.1.1
The alarm code. The following attributes refer this code.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnCnfgAlrSlot 1.3.6.1.4.1.164.3.1.2.2.8.2.1.2
The alarm slot. The following attributes apply for the alarm code and slot selected. all = the attributes apply to all slots. notApplicable = the selected alarm is for system level.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER psA(1), psB(2), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), all(200), notApplicable(255)  

agnCnfgAlrPort 1.3.6.1.4.1.164.3.1.2.2.8.2.1.3
The alarm port. The following attributes apply for the alarm code,slot and port selected. 200 = all = the attributes apply to all ports of the selected slot. When selected Slot is 'all', only 'all' or 'notApplicable' are valid Port selections. notApplicable = the selected alarm is for system or card level. =255 for MP =100 for DXC - For MP, valid cards' ports are: exPrt1(1)..exPrt12(12) inPrt1(101)..inPrt48 (148) - For DXC, the port index will include the Slot, as for all DXC tables: [(IO Slot+10)&n] ; n=odd for external ports n=even for internal ports.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnCnfgAlrMask 1.3.6.1.4.1.164.3.1.2.2.8.2.1.4
An attribute defining the desired Mask state of an alarm . no - unmask (this command is not saved in agent's common database) noAndSave - unmask ; this command is saved in agent's common database yes - mask (this command is not saved in agent's common database) yesAndSave - mask ; this command is saved in agent's common database. Commands that are not saved, will be lost upon power-up or selected card removal.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), noAndSave(2), yes(3), yesAndSave(4)  

agnCnfgAlrInvert 1.3.6.1.4.1.164.3.1.2.2.8.2.1.5
An attribute defining the desired Invert state of an alarm . no - not inverted. yes - inverted. For MP, it is not applicable for alarms that are currently OFF.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

agnCnfgAlrFilter 1.3.6.1.4.1.164.3.1.2.2.8.2.1.6
An attribute defining if Filter is desired for the alarm . no - no filter. yes - filter activate. This filter is activated within a window of time defined by agnCnfgAlrFilterWindow. Its purpose is to avoid frequent changes of an alarm between ON/OFF states.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

agnCnfgAlrFilterSet 1.3.6.1.4.1.164.3.1.2.2.8.2.1.7
This is a top threshold causing the alarm that passes it, to be declared Set (ON) at the end of the respective window of time. - For alarms defined by default as state alarms (minor,major) this value will be in [%]. - For alarms defined by default as events, this value will be an integer meaning how many times this event should appear at least, during the window in order to be considered ON. The maximum valuewill be 255. This value should be greater than the one of agnCnfgAlrFilterReset. Agents that do not support Alarms Filter, will return 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

agnCnfgAlrFilterReset 1.3.6.1.4.1.164.3.1.2.2.8.2.1.8
This is a bottom threshold causing the alarm that does not pass it, to be declared Reset (ON) at the end of the respective window of time. - For alarms defined by default as state alarms (minor,major) this value will be in [%]. - For alarms defined by default as events, this value will be an integer meaning how many times this event should appear at most, during the window, in order to be considered OFF. This value should be less than the one of agnCnfgAlrFilterSet. Agents that do not support Alarms Filter, will return 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

agnCnfgAlrReportTable 1.3.6.1.4.1.164.3.1.2.2.8.3
This table enables the user to configure the desired Alarm Reports according to alarms severity.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnCnfgAlrReportEntry

agnCnfgAlrReportEntry 1.3.6.1.4.1.164.3.1.2.2.8.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AgnCnfgAlrReportEntry  

agnCnfgAlrReportType 1.3.6.1.4.1.164.3.1.2.2.8.3.1.1
The alarm report type. trap - traps will be sent only for alarms having the selected On/Off severity or higher. buffer - only alarms having the selected On/Off severity and higher, will be reported to the buffer. relay - relay contact will be activated only for alarms having the selected On severity or higher. For products having 2 relays, this is the Minor Relay. alrLedOn/alrLedBlink - user should select a higher severity (ReportOn) for alrLedBlink than for alrLedOn (Blinking Led means a more severe alarm than steady ON Led). alrLedOn - MTCL-1 Alarm Led will be ON only when agnSAlrStatusAll equals the selected severity or higher, but lower severity than that selected for 'alrLedBlink'. For products having 2 LEDs, this is the Minor LED. alrLedBlink - MTCL-1 Alarm Led will Blink only when agnSAlrStatusAll equals the selected severity or higher. For products having 2 LEDs, this is the Major LED. relay2 - relay 2 contact will be activated only for alarms having the selected On severity or higher. This is the Major Relay.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER trap(1), buffer(2), relay(3), alrLedOn(4), alrLedBlink(5), relay2(6)  

agnCnfgAlrStartReportOn 1.3.6.1.4.1.164.3.1.2.2.8.3.1.2
This object specifies the severity from which alarms will be reported. Alarms having this severity or higher, will be reported. This object specifies the report severity only for alarms that turn to ON state. noReport - no Report at all (for any severity).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noReport(2), event(3), minor(4), major(5), warning(6), critical(7)  

agnCnfgAlrStartReportOff 1.3.6.1.4.1.164.3.1.2.2.8.3.1.3
This object specifies the severity from which alarms will be reported. Alarms having this severity or higher, will be reported. This object specifies the report severity only for alarms that turn to OFF state. notApplicable - for 'relay','alrLedOn','alrLedBlink', 'relay2' report types, in MP. noReport - no Report at all (for any severity).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), noReport(2), event(3), minor(4), major(5), warning(6), critical(7)  

agnCOffsetCmd 1.3.6.1.4.1.164.3.1.2.2.9
An object defining special user request. notApplicable - is RO value for products that do not support this object. normal - nothing special u1 - user 1 - for all Voice cards, the DISPLAYED Tx and Rx Levels will have the following Offsets: - 2 Wires port: Tx Level: the base value (for 0dBm) = 0 Rx Level: the base value (for 0dBm) = -2 - 4 Wires port: Tx Level: the base value (for 0dBm) = -16 Rx Level: the base value (for 0dBm) = 7 The MIB and application DB will use the values without Offset.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), normal(2), u1(3)  

agnCmprTable 1.3.6.1.4.1.164.3.1.2.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnCmprEntry

agnCmprEntry 1.3.6.1.4.1.164.3.1.2.3.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AgnCmprEntry  

agnCmprTypIdx 1.3.6.1.4.1.164.3.1.2.3.1.1.1
This attribute indicates the Type of the Compressed being referred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnCmprCnfgIdx 1.3.6.1.4.1.164.3.1.2.3.1.1.2
This attribute indicates the configuration to which the Compressed information is related.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnCmprVersion 1.3.6.1.4.1.164.3.1.2.3.1.1.3
This attribute indicates the version of the internal format of the Compressed data
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnCmprObj 1.3.6.1.4.1.164.3.1.2.3.1.1.4
This attribute is the compressed information itself.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

agnDlciCmprTable 1.3.6.1.4.1.164.3.1.2.3.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnDlciCmprEntry

agnDlciCmprEntry 1.3.6.1.4.1.164.3.1.2.3.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AgnDlciCmprEntry  

agnDlciCmprCnfgIdx 1.3.6.1.4.1.164.3.1.2.3.2.1.1
This attribute indicates the configuration to which the Compressed information is related.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnDlciCmprVersion 1.3.6.1.4.1.164.3.1.2.3.2.1.2
This attribute indicates the version of the internal format of the Compressed data
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnDlciCmprDlciIdx 1.3.6.1.4.1.164.3.1.2.3.2.1.3
This attribute indicates a unique identifier of the Dlci, the compressed information relates to. The values are between 16 - 991.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnDlciCmprObj 1.3.6.1.4.1.164.3.1.2.3.2.1.4
This attribute is the compressed information itself.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

agnAlarmsCmprTable 1.3.6.1.4.1.164.3.1.2.3.3
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnAlarmsCmprEntry

agnAlarmsCmprEntry 1.3.6.1.4.1.164.3.1.2.3.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AgnAlarmsCmprEntry  

agnAlarmsCmprVersion 1.3.6.1.4.1.164.3.1.2.3.3.1.1
This attribute indicates the version of the internal format of the Compressed data
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnAlarmsCmprAlarmIdx 1.3.6.1.4.1.164.3.1.2.3.3.1.2
A unique number to identify an entry in the alarm status table of the agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnAlarmsCmprObj 1.3.6.1.4.1.164.3.1.2.3.3.1.3
This attribute is the compressed information itself.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

agnAlrBufCmprTable 1.3.6.1.4.1.164.3.1.2.3.4
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnAlrBufCmprEntry

agnAlrBufCmprEntry 1.3.6.1.4.1.164.3.1.2.3.4.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AgnAlrBufCmprEntry  

agnAlrBufCmprVersion 1.3.6.1.4.1.164.3.1.2.3.4.1.1
This attribute indicates the version of the internal format of the Compressed data
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnAlrBufCmprAlarmIdx 1.3.6.1.4.1.164.3.1.2.3.4.1.2
A unique number to identify an entry in the history alarms buffer of the agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnAlrBufCmprObj 1.3.6.1.4.1.164.3.1.2.3.4.1.3
This attribute is the compressed information itself.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

agnSCmprErrListTable 1.3.6.1.4.1.164.3.1.2.3.5
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnSCmprErrListEntry

agnSCmprErrListEntry 1.3.6.1.4.1.164.3.1.2.3.5.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AgnSCmprErrListEntry  

agnSCmprErrVersion 1.3.6.1.4.1.164.3.1.2.3.5.1.1
The version of the compressed data
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnSCmprErrIdx 1.3.6.1.4.1.164.3.1.2.3.5.1.2
Unique number to identify an entry in the errors list table. The maximum entry value cannot exceed the value of 'agnSNoOfSanityCheckErr'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnSCmprErrObj 1.3.6.1.4.1.164.3.1.2.3.5.1.3
This attribute is a full text description of the error, including: error code, slot and port numbers related to the code .
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

agnTsCmprTable 1.3.6.1.4.1.164.3.1.2.3.6
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnTsCmprEntry

agnTsCmprEntry 1.3.6.1.4.1.164.3.1.2.3.6.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AgnTsCmprEntry  

agnTsCmprVerIdx 1.3.6.1.4.1.164.3.1.2.3.6.1.1
This object indicates the version of the internal format of the Compressed data.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnTsCmprCnfgIdx 1.3.6.1.4.1.164.3.1.2.3.6.1.2
This object indicates the configuration to which the Compressed information is related. 255=temporary configuration. Set can be performed only to the temporary configuration.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnTsCmprSlotIdx 1.3.6.1.4.1.164.3.1.2.3.6.1.3
This object indicates the Slot to which the Compressed information is related. For MP-2100: IO-1..IO-12 = (5).. (16) For DXC-30 : IO-1..IO-15 = (5).. (19).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnTsCmprPortIdx 1.3.6.1.4.1.164.3.1.2.3.6.1.4
This object indicates the Port within the Slot, to which the Compressed information is related. For Port Index see each product's spec.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnTsCmprPduIdx 1.3.6.1.4.1.164.3.1.2.3.6.1.5
This object indicates the PDU index within the same port. That provides for the case when one PDU is not sufficient for all TS Assignment data of the same port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnTsCmprData 1.3.6.1.4.1.164.3.1.2.3.6.1.6
This object is the compressed information itself. It provides information about all TSs of a port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

agnXCmprTable 1.3.6.1.4.1.164.3.1.2.3.7
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnXCmprEntry

agnXCmprEntry 1.3.6.1.4.1.164.3.1.2.3.7.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AgnXCmprEntry  

agnXCmprTypIdx 1.3.6.1.4.1.164.3.1.2.3.7.1.1
This attribute indicates the Type of the Compressed being referred. One of the types is V5.1 Variant data.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnXCmprVersion 1.3.6.1.4.1.164.3.1.2.3.7.1.2
This attribute indicates the version of the internal format of the Compressed data.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnXCmprIdx3 1.3.6.1.4.1.164.3.1.2.3.7.1.3
3rd index - can be used for any purpose according to the agnXCmprTypIdx. Example: for V5.1 Variant, this attribute indicates the configuration to which the Compressed information is related. 255=temporary configuration. Set can be performed only to the temporary configuration.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnXCmprIdx4 1.3.6.1.4.1.164.3.1.2.3.7.1.4
4th index - can be used for any purpose according to the agnXCmprTypIdx. Example: for V5.1 Variant,this attribute indicates a unique number of the slot position where the card is inserted. Valid values: psA(1),psB(2),clA(3),clB(4),io1(5)..io12(16); notApplicable=255.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnXCmprIdx5 1.3.6.1.4.1.164.3.1.2.3.7.1.5
5th index - can be used for any purpose according to the agnXCmprTypIdx. Example: for V5.1 Variant,this attribute indicates a unique identifier of the port the compressed information relates to. Valid values: exPrt1 (1) .. exPrt12 (12) , inPrt1 (101) .. inPrt48 (148).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnXCmprIdx6 1.3.6.1.4.1.164.3.1.2.3.7.1.6
6th index - can be used for any purpose according to the agnXCmprTypIdx. Example: for V5.1 Variant,this attribute indicates the Variant index. Valid values are: 0..127, 255 (= temp cnfg).Set can be performed only to the temporary configuration.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnXCmprIdx7 1.3.6.1.4.1.164.3.1.2.3.7.1.7
7th index - can be used for any purpose according to the agnXCmprTypIdx. Example: for V5.1 Variant,this attribute is not needed. Therefore, its value will be always 255=notApplicable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnXCmprObj 1.3.6.1.4.1.164.3.1.2.3.7.1.8
This attribute is the compressed information itself.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

agnLinkMapTable 1.3.6.1.4.1.164.3.1.5.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnLinkMapEntry

agnLinkMapEntry 1.3.6.1.4.1.164.3.1.5.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AgnLinkMapEntry  

mapLinkId 1.3.6.1.4.1.164.3.1.5.1.1.1
A unique identifier of the link
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mapLinkSltIdx 1.3.6.1.4.1.164.3.1.5.1.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries clA(3), io6(10)..io12(16) are not valid.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noConnect(2), clA(3), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

mapLinkPrtIdx 1.3.6.1.4.1.164.3.1.5.1.1.3
This attribute indicates a unique port number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), exPrt9(9), exPrt10(10), exPrt11(11), exPrt12(12), noConnect(100), inPrt1(101), inPrt2(102), inPrt3(103), inPrt4(104), inPrt5(105), inPrt6(106), inPrt7(107), inPrt8(108), inPrt9(109), inPrt10(110), inPrt11(111), inPrt12(112)  

mapLinkStatus 1.3.6.1.4.1.164.3.1.5.1.1.4
This attribute indicates the status of the link between the two muxes
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), down(2), up(3)  

ethIf 1.3.6.1.4.1.164.3.1.6.1
OBJECT IDENTIFIER    

ethIfTable 1.3.6.1.4.1.164.3.1.6.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EthIfEntry

ethIfEntry 1.3.6.1.4.1.164.3.1.6.1.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  EthIfEntry  

ethIfIdx 1.3.6.1.4.1.164.3.1.6.1.1.1.1
A unique index of the ethernet interface/port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ethMode 1.3.6.1.4.1.164.3.1.6.1.1.1.2
This object indicates the Ethernet mode of operation.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER halfDuplex(1), fullDuplex(2)  

ethBridgingMode 1.3.6.1.4.1.164.3.1.6.1.1.1.3
This object indicates the bridging mode of the Ethernet interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER filtered(1), transparent(2)  

alrBufTable 1.3.6.1.4.1.164.3.1.2.4.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AlrBufEntry

alrBufEntry 1.3.6.1.4.1.164.3.1.2.4.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AlrBufEntry  

alrBufIdx 1.3.6.1.4.1.164.3.1.2.4.1.1.1
This attribute indicates a unique number to identify this entry
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

alrBufDescription 1.3.6.1.4.1.164.3.1.2.4.1.1.2
This entry is a unique text description of the alarm in the buffer. The alarm description includes the following information: alarm code, slot id, card type, channel id , alarm text, alarm status, masked flag and event counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

agnCAgendaTable 1.3.6.1.4.1.164.3.1.2.5.1
This table devides the week days into categories needed for DB flip consideration.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnCAgendaEntry

agnCAgendaEntry 1.3.6.1.4.1.164.3.1.2.5.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AgnCAgendaEntry  

agnCAgendaCnfgIdx 1.3.6.1.4.1.164.3.1.2.5.1.1.1
Active or Temporary Agenda Table. Both configurations can be read but only the Temporary can be written to.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER active(1), temporary(255)  

agnCAgendaDayIdx 1.3.6.1.4.1.164.3.1.2.5.1.1.2
Day of week
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER sunday(1), monday(2), tuesday(3), wednesday(4), thursday(5), friday(6), saturday(7)  

agnCAgendaDayCategory 1.3.6.1.4.1.164.3.1.2.5.1.1.3
The Category of the Day
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER fullWorkday(1), partialWorkday(2), weekend(3)  

agnCFlipNetEventsTable 1.3.6.1.4.1.164.3.1.2.5.2
This table holds the Net Events the MUX should trace
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnCFlipNetEventsEntry

agnCFlipNetEventsEntry 1.3.6.1.4.1.164.3.1.2.5.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AgnCFlipNetEventsEntry  

agnCFlipNetEventsCnfgIdx 1.3.6.1.4.1.164.3.1.2.5.2.1.1
Active or Temporary Net Events Table. Both configurations can be read but only the Temporary can be written to.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER active(1), temporary(255)  

agnCFlipNetEventIdx 1.3.6.1.4.1.164.3.1.2.5.2.1.2
Entry within the table
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..10  

agnCFlipNetEventActive 1.3.6.1.4.1.164.3.1.2.5.2.1.3
Indicates if the entry is valid. In order to Add/Modify parameters of an entry, this object should be set to Yes. In order to delete an entry, this object should be Set to No.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

agnCFlipNetEventType 1.3.6.1.4.1.164.3.1.2.5.2.1.4
The Net Event type
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER time(1), linkDown(2), congestion(3)  

agnCFlipNetEventNo 1.3.6.1.4.1.164.3.1.2.5.2.1.5
The Net Event No. (Bit Index)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..512  

agnCFlipNetEventSlot 1.3.6.1.4.1.164.3.1.2.5.2.1.6
The slot to which the net event relates . Not applicable for time event
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

agnCFlipNetEventPort 1.3.6.1.4.1.164.3.1.2.5.2.1.7
The port within the relevant slot
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), exPrt9(9), exPrt10(10), exPrt11(11), exPrt12(12), notApplicable(100), inPrt1(101), inPrt2(102), inPrt3(103), inPrt4(104), inPrt5(105), inPrt6(106), inPrt7(107), inPrt8(108)  

agnCFlipNetEventISD 1.3.6.1.4.1.164.3.1.2.5.2.1.8
The time in seconds since the Net Event was reported as ON until it is considered as ON. Not relevant for time events.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..999  

agnCFlipNetEventOSD 1.3.6.1.4.1.164.3.1.2.5.2.1.9
The time in seconds since the net event was reported as OFF until it is considered as OFF. Not relevant for time events.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..999  

agnCFlipNetEventDayType 1.3.6.1.4.1.164.3.1.2.5.2.1.10
The time event relates to all days defined in this category in the agnCAgendaTable. Applicable only for time event
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), fullWorkday(2), partialWorkday(3), weekend(4)  

agnCFlipNetEventStartTime 1.3.6.1.4.1.164.3.1.2.5.2.1.11
The time event will be activated at this time. The format is hh:mm.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(5)  

agnCFlipNetEventEndTime 1.3.6.1.4.1.164.3.1.2.5.2.1.12
The time event will be deactivated at this time. The format is hh:mm.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(5)  

agnCFlipTable 1.3.6.1.4.1.164.3.1.2.5.3
The DB Flip Decisions Table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnCFlipEntry

agnCFlipEntry 1.3.6.1.4.1.164.3.1.2.5.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AgnCFlipEntry  

agnCFlipCnfgIdx 1.3.6.1.4.1.164.3.1.2.5.3.1.1
Active or Temporary Flip Decisions Table. Both configurations can be read but only the Temporary can be written to.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER active(1), temporary(255)  

agnCFlipIdx 1.3.6.1.4.1.164.3.1.2.5.3.1.2
Entry number within the table
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..10  

agnCFlipActive 1.3.6.1.4.1.164.3.1.2.5.3.1.3
Indicates if the entry is valid. In order to Add/Modify parameters of an entry this object should be Set to Yes. In order to delete an entry, this object should be Set to No.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

agnCFlipLogicalExp 1.3.6.1.4.1.164.3.1.2.5.3.1.4
A logical expression composed of events numbers (which were configured in the 'AgnCFlipNetEvantsTable') and logical operators ('|', '&', '!', '(', ')') between them. e.g - (1 & !2) | (121 & 230)
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..20)  

agnCFlipDbNo 1.3.6.1.4.1.164.3.1.2.5.3.1.5
The ID of the required DB
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..10  

agnCFlipDiscardDe 1.3.6.1.4.1.164.3.1.2.5.3.1.6
Indicates whether the Mux should start discarding all DE. (MP3000 Only).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

agnFlipDbControls 1.3.6.1.4.1.164.3.1.2.5.4
OBJECT IDENTIFIER    

agnCFlipDbSanityCheckCmd 1.3.6.1.4.1.164.3.1.2.5.4.1
Setting this attribute to on(3) will initiate the process of Sanity check on the Temp Flip Db and automatically be changed to off(2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

agnCSaveFlipDbCmd 1.3.6.1.4.1.164.3.1.2.5.4.2
Setting this attribute to on(3) will initiate the process of Sanity check on the Temp Flip Db and if it is OK, it will save the Flip Db in the NVRAM, activating the new Flip DB . If check detects errors, the save will not be performed. Afterwards, the object's value will change automatically to off(2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

agnCSaveNetCnfgIdxCmd 1.3.6.1.4.1.164.3.1.2.5.4.3
This attribute specifies the Id of the target NVRAM Cnfg to which the TmpCnfg should be transferred. Upon set command the MUX will initiate the Sanity-Check process first. If successful, the actual transfer will be performed. If warnings are detected, the user will have to perform the command again to confirm the operation. Setting this object a second time to the same value without performing any change in the database, will cause the result: agnSSanityCheckStatus = unknown. This attribute doesn't cause actual Flip.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..10  

agnCSaveNetFlipDbCmd 1.3.6.1.4.1.164.3.1.2.5.4.4
Setting this attribute to on(3) will save the Temp Flip DB Into the NVRAM without actual flip.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

agnCNetGoCmd 1.3.6.1.4.1.164.3.1.2.5.4.5
Setting this attribute to On will broadcast a 'GO' command to the network. When a Mux receives a 'GO' command it issues a delay for 'agnCNetDelay' seconds and then activates the DB which was pre-defined by one of the commands : 'agnCSaveNetCnfgIdxCmd' or 'agnCSaveNetFlipDbCmd'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

agnCNetDelay 1.3.6.1.4.1.164.3.1.2.5.4.6
This attribute determines the period of time in seconds that takes for a message to be transferred over all the network. After a 'GO' command the MUX issues a delay of 'agnCNetDelay' before activating the appropriate DB. The delay will be applied only after performing agnCSaveFlipDbCmd.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..999  

agnCNetEventsBcast 1.3.6.1.4.1.164.3.1.2.5.4.7
This object determines if the Net Events will be Broadcasted to other Muxes of the Net or not. disabled - Net Events will NOT be Broadcasted enabled - Net Events will be Broadcasted. Default=disabled. The value will be applied only after performing agnCSaveFlipDbCmd.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(2), enabled(3)  

agnCNetEventsBcastInterval 1.3.6.1.4.1.164.3.1.2.5.4.8
When agnCNetEventsBcast is enabled, this object determines the interval of time in seconds, between two consecutive Net Events transferred over the network. Default=40 sec. The interval will be applied only after performing agnCSaveFlipDbCmd.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..60  

agnSaSwchStatus 1.3.6.1.4.1.164.3.1.2.6.1
This object indicates the status of the switches on the stand-alone unit. Each switch is represented by a bit. The status is a sum of 2**n, according to the bits: bit 0 NMS (LSB) bit 1 Terminal '1' = forces the DCE to be terminal with Rate=9600bps, Data bits=8, Stop bits=1 bit 2 Xray bit 3 SW-Load '1' = when SW is loaded bit 4 DBS Default of all bits=0 When the status of these switches is unknown, the value of this object is 255.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnListDecodingTable 1.3.6.1.4.1.164.3.1.2.7.1
A decoding table . For each type of list, a description is given for each existing code.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnListDecodingEntry

agnListDecodingEntry 1.3.6.1.4.1.164.3.1.2.7.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AgnListDecodingEntry  

agnListDecodingType 1.3.6.1.4.1.164.3.1.2.7.1.1.1
The type of list the decoding data refers to. alr - Alarms list sanity - Sanity Check Error list.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER alr(1), sanity(2)  

agnListDecodingCode 1.3.6.1.4.1.164.3.1.2.7.1.1.2
The specific code for which decoding is needed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnListDecodingDescription 1.3.6.1.4.1.164.3.1.2.7.1.1.3
The description fitting the specific code and type of list required.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

agnListDecodingDefState 1.3.6.1.4.1.164.3.1.2.7.1.1.4
This object is applicable only for agnListDecodingType=alr. It reports the default state/severity of each alarm. User can change the severity of the alarms defined by this default via the agnListDecodingSeverity object.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), event(3), minor(4), major(5)  

agnListDecodingSeverity 1.3.6.1.4.1.164.3.1.2.7.1.1.5
This object is applicable only for agnListDecodingType=alr. It enables the user to select a severity for each alarm. The severity is set per alarm code (same for all slots/ports using this code). event - can be set only for an alarm that is defined by default as 'event'. User can change the severity of the alarms defined by default as minor or major. The severity of an event may be set to another severity, but the change will actually happen only if the event threshold is active and passed the Set/ON condition. An event alarm that passed the threshold and changed its severity, will return automatically to event severity when meeting its Reset/OFF condition.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), event(3), minor(4), major(5), warning(6), critical(7)  

agnListDecodingAcmRelaySlt 1.3.6.1.4.1.164.3.1.2.7.1.1.6
This object indicates the ACM slot, desired for outbound relay (report) for the selected alarm. In the ?004 Unit the entries io6(10)..io12(16) are not valid. none - when agnListDecodingType=alr AND the selected alarm should not be reported by an ACM card. notApplicable - when agnListDecodingType=sanity OR when [agnListDecodingType=alr and there is no ACM card installed in the Mux].
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

agnListDecodingAcmRelayPrt 1.3.6.1.4.1.164.3.1.2.7.1.1.7
This object indicates the ACM port within the slot, desired for outbound relay (report) for the selected alarm. notApplicable - when agnListDecodingType=sanity OR when agnListDecodingAcmRelaySlt=notApplicable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), notApplicable(255)  

agnDlciTable 1.3.6.1.4.1.164.3.1.2.8.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnDlciEntry

agnDlciEntry 1.3.6.1.4.1.164.3.1.2.8.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AgnDlciEntry  

agnDlciCnfgIdx 1.3.6.1.4.1.164.3.1.2.8.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

agnDlciLSltIdx 1.3.6.1.4.1.164.3.1.2.8.1.1.2
This attribute indicates a unique slot position where the card is inserted. vs=Voice Switching In the ?004 Unit the entries io6(10)..io16) are not valid. For ISDN BRI ports of MX300/30 units: io1(5) = isdn1(5) and io2(6) = isdn2(6) LSlotIdx is defined according one of the following possiblities: 1. LSlotIdx is < HSlotIdx. 2. LSlotIdx is = HSlotIdx and LPrtIdx is < HPrtIdx. 3. LSlotIdx is = HSlotIdx and LPrtIdx is = HPrtIdx but LIdx is < HIdx.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER cl(3), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), vs(254), notApplicable(255)  

agnDlciLPrtIdx 1.3.6.1.4.1.164.3.1.2.8.1.1.3
This attribute indicates a unique external or internal port number, including linkSelector or encapsulator. 100=noConnect (for voice switching) LPrtIdx is defined according one of the following possiblities: 1. LSlotIdx is < HSlotIdx. 2. LSlotIdx is = HSlotIdx and LPrtIdx is < HPrtIdx. 3. LSlotIdx is = HSlotIdx and LPrtIdx is = HPrtIdx but LIdx is < HIdx.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnDlciLIdx 1.3.6.1.4.1.164.3.1.2.8.1.1.4
This attribute indicates a unique index for each possible used dlci(16..991). 0=notApplicable (for voice switching) LIdx is defined according one of the following possiblities: 1. LSlotIdx is < HSlotIdx. 2. LSlotIdx is = HSlotIdx and LPrtIdx is < HPrtIdx. 3. LSlotIdx is = HSlotIdx and LPrtIdx is = HPrtIdx but LIdx is < HIdx.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..991  

agnDlciHSltIdx 1.3.6.1.4.1.164.3.1.2.8.1.1.5
This attribute indicates a unique slot position In the Mux (Agent) where the dlci is routed to. For ISDN BRI ports of MX300/30 units: io1(5) = isdn1(5) and io2(6) = isdn2(6) In the ?004 Unit the entries io6(10)..io16) are not valid
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER cl(3), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

agnDlciHPrtIdx 1.3.6.1.4.1.164.3.1.2.8.1.1.6
This attribute indicates a unique port id which the dlci is routed to.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnDlciHIdx 1.3.6.1.4.1.164.3.1.2.8.1.1.7
This attribute indicates a unique internal connection dlci number which the src dlci is routed to.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..991  

agnDlciTxBc 1.3.6.1.4.1.164.3.1.2.8.1.1.8
This attribute indicates a unique Tx committed bandwidth on the user transmit line or at the port receive line.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER full(1), zero(2), txBc5100bps(3), txBc6400bps(4), txBc8300bps(5), txBc9600bps(6), txBc14400bps(7), txBc19200bps(8), txBc28800bps(9), txBc32000bps(10), txBc38400bps(11), txBc48000bps(12), txBc56000bps(13), txBc57600bps(14), txBc64Kbps(15), txBc128Kbps(16), txBc192Kbps(17), txBc256Kbps(18), txBc320Kbps(19), txBc384Kbps(20), txBc448Kbps(21), txBc512Kbps(22), txBc768Kbps(23), txBc896Kbps(24), txBc1024Kbps(25), txBc1152Kbps(26), txBc1280Kbps(27), txBc1344Kbps(28), txBc1472Kbps(29), txBc1600Kbps(30), txBc1728Kbps(31), txBc1856Kbps(32), txBc1920Kbps(33), txBc1984Kbps(34), txBc2048Kbps(35), txBc16000bps(36), txBc112Kbps(37), txBc168Kbps(38), txBc224Kbps(39), txBc336Kbps(40), txBc672Kbps(41), txBc1536Kbps(42), txBc1792Kbps(43)  

agnDlciTxBe 1.3.6.1.4.1.164.3.1.2.8.1.1.9
This attribute indicates a unique Tx excess bandwidth on the user transmit line or at the port receive line.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER full(1), zero(2), txBe5100bps(3), txBe6400bps(4), txBe8300bps(5), txBe9600bps(6), txBe14400bps(7), txBe19200bps(8), txBe28800bps(9), txBe32000bps(10), txBe38400bps(11), txBe48000bps(12), txBe56000bps(13), txBe57600bps(14), txBe64Kbps(15), txBe128Kbps(16), txBe192Kbps(17), txBe256Kbps(18), txBe320Kbps(19), txBe384Kbps(20), txBe448Kbps(21), txBe512Kbps(22), txBe768Kbps(23), txBe896Kbps(24), txBe1024Kbps(25), txBe1152Kbps(26), txBe1280Kbps(27), txBe1344Kbps(28), txBe1472Kbps(29), txBe1600Kbps(30), txBe1728Kbps(31), txBe1856Kbps(32), txBe1920Kbps(33), txBe1984Kbps(34), txBe2048Kbps(35), txBe16000bps(36), txBe112Kbps(37), txBe168Kbps(38), txBe224Kbps(39), txBe336Kbps(40), txBe672Kbps(41), txBe1536Kbps(42), txBe1792Kbps(43)  

agnDlciRxBc 1.3.6.1.4.1.164.3.1.2.8.1.1.10
This attribute indicates a unique Rx committed bandwidth on the user receive line or at the port transmit line.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER full(1), zero(2), rxBc5100bps(3), rxBc6400bps(4), rxBc8300bps(5), rxBc9600bps(6), rxBc14400bps(7), rxBc19200bps(8), rxBc28800bps(9), rxBc32000bps(10), rxBc38400bps(11), rxBc48000bps(12), rxBc56000bps(13), rxBc57600bps(14), rxBc64Kbps(15), rxBc128Kbps(16), rxBc192Kbps(17), rxBc256Kbps(18), rxBc320Kbps(19), rxBc384Kbps(20), rxBc448Kbps(21), rxBc512Kbps(22), rxBc768Kbps(23), rxBc896Kbps(24), rxBc1024Kbps(25), rxBc1152Kbps(26), rxBc1280Kbps(27), rxBc1344Kbps(28), rxBc1472Kbps(29), rxBc1600Kbps(30), rxBc1728Kbps(31), rxBc1856Kbps(32), rxBc1920Kbps(33), rxBc1984Kbps(34), rxBc2048Kbps(35), rxBc16000bps(36), rxBc112Kbps(37), rxBc168Kbps(38), rxBc224Kbps(39), rxBc336Kbps(40), rxBc672Kbps(41), rxBc1536Kbps(42), rxBc1792Kbps(43)  

agnDlciRxBe 1.3.6.1.4.1.164.3.1.2.8.1.1.11
This attribute indicates a unique Rx excess bandwidth on the user receive line or at the port transmit line.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER full(1), zero(2), rxBe5100bps(3), rxBe6400bps(4), rxBe8300bps(5), rxBe9600bps(6), rxBe14400bps(7), rxBe19200bps(8), rxBe28800bps(9), rxBe32000bps(10), rxBe38400bps(11), rxBe48000bps(12), rxBe56000bps(13), rxBe57600bps(14), rxBe64Kbps(15), rxBe128Kbps(16), rxBe192Kbps(17), rxBe256Kbps(18), rxBe320Kbps(19), rxBe384Kbps(20), rxBe448Kbps(21), rxBe512Kbps(22), rxBe768Kbps(23), rxBe896Kbps(24), rxBe1024Kbps(25), rxBe1152Kbps(26), rxBe1280Kbps(27), rxBe1344Kbps(28), rxBe1472Kbps(29), rxBe1600Kbps(30), rxBe1728Kbps(31), rxBe1856Kbps(32), rxBe1920Kbps(33), rxBe1984Kbps(34), rxBe2048Kbps(35), rxBe16000bps(36), rxBe112Kbps(37), rxBe168Kbps(38), rxBe224Kbps(39), rxBe336Kbps(40), rxBe672Kbps(41), rxBe1536Kbps(42), rxBe1792Kbps(43)  

agnDlciPriority 1.3.6.1.4.1.164.3.1.2.8.1.1.12
This attribute indicates a unique priority of the pcv. 1 is the lowest priority and 7 is the highest priority.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..8  

agnDlciStatus 1.3.6.1.4.1.164.3.1.2.8.1.1.13
This attribute indicates the status of the pvc. The status is disconnected(1) when one of the sides is programmed as not connected
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disconnected(1), connected(2)  

agnDlciSpoofing 1.3.6.1.4.1.164.3.1.2.8.1.1.14
This object refers to sending of RIP messages: - yes : RIP messages will be sent ONLY if there is a change in the Net. - no : RIP messages will be always sent. This object is relevant only when one side of the DLCI is a CL-NMS interface. Default=no.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

agnDlciFunnelEnable 1.3.6.1.4.1.164.3.1.2.8.1.1.15
This object selects Funnel activation enable/disable: - disabled: Funnel operation disabled. The agnDlciTxBe and agnDlciTxBc values are not used for funneling. - enabled : Funnel operation enabled. The agnDlciTxBe and agnDlciTxBc values are used for funneling calculations. This object is relevant only for an encapsulating DLCI. In case of a Link Selector DLCI, the agnDlciTxBe and agnDlciTxBc values are used for bandwidth of Link Selector. Default=disabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(2), enabled(3)  

agnDlciRoutingProtocol 1.3.6.1.4.1.164.3.1.2.8.1.1.16
This object is relevant only when one side of the DLCI is a CL-NMS interface. It defines which Routing Protocol will be used for management via CL-NMS port. notApplicable will be used for all slots but CL. rip is a proprietary rip protocol. Default=rip.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), rip(2), rip2(3), none(4)  

agnDlciRowStatus 1.3.6.1.4.1.164.3.1.2.8.1.1.17
This attribute allows to create/delete a row in this table. For creating a row, the NMS should set agnRowStatus.255.id2.id3.id4.id5.id6.id7 = active(1). For destroying a row, the NMS should set: agnRowStatus.255.id2.id3.id4.id5.id6.id7 = destroy(6). Only rows with status active(1) are relevant.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER active(1), destroy(6)  

agnVoiceSwConfTable 1.3.6.1.4.1.164.3.1.2.9.1
MXcess Configuration for Voice Switching.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnVoiceSwConfEntry

agnVoiceSwConfEntry 1.3.6.1.4.1.164.3.1.2.9.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AgnVoiceSwConfEntry  

agnVoiceSwConfIdx 1.3.6.1.4.1.164.3.1.2.9.1.1.1
Active or Temporary Table. Both configurations can be read but only the Temporary can be written to.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER active(1), temporary(255)  

agnVoiceSwConfZoneId 1.3.6.1.4.1.164.3.1.2.9.1.1.2
1 or 2 digits, (0-9)(1-9).
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..2)  

agnVoiceSwConfNodeId 1.3.6.1.4.1.164.3.1.2.9.1.1.3
1, 2 or 3 digits, (1-9),(0-9),(0-9).
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..3)  

agnVoiceSwConfNoOfHops 1.3.6.1.4.1.164.3.1.2.9.1.1.4
Number of hops the frame will go through the net before deciding to discard the frame (like time-to-live in IP). 0 = notApplicable Default=20 .
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..20  

agnVoiceSwConfRtTable 1.3.6.1.4.1.164.3.1.2.9.2
Routing Table for Voice Switching.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnVoiceSwConfRtEntry

agnVoiceSwConfRtEntry 1.3.6.1.4.1.164.3.1.2.9.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AgnVoiceSwConfRtEntry  

agnVoiceSwConfRtDbId 1.3.6.1.4.1.164.3.1.2.9.2.1.1
Active or Temporary Table. Both configurations can be read but only the Temporary can be written to.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER active(1), temporary(255)  

agnVoiceSwConfRtIdx 1.3.6.1.4.1.164.3.1.2.9.2.1.2
The Index of the row.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnVoiceSwConfRtDigits 1.3.6.1.4.1.164.3.1.2.9.2.1.3
Serie of digits or keyword 'ELSE'..
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..7)  

agnVoiceSwConfRtAction 1.3.6.1.4.1.164.3.1.2.9.2.1.4
Action that the system should perform for this digits: agnVoiceSwConfRtDigits.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), zone(2), node(3), shortDialing(4), in(5), hgr(6), del(7), rep(8)  

agnVoiceSwConfRtData 1.3.6.1.4.1.164.3.1.2.9.2.1.5
This field is relevant for actions hgr(6), del(7) and rep(8).
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..7)  

agnVoiceSwConfRtSlot 1.3.6.1.4.1.164.3.1.2.9.2.1.6
Routing Slot- Relevant for actions zone(2) and node(3).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noConnect(2), cl(3), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

agnVoiceSwConfRtPort 1.3.6.1.4.1.164.3.1.2.9.2.1.7
Routing Port- Relevant for actions zone(2) and node(3). 100=noConnect (for non-routing case).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

agnVoiceSwConfRtDlci 1.3.6.1.4.1.164.3.1.2.9.2.1.8
Routing DLCI- Relevant for actions zone(2) and node(3). Valid values: 0=notApplicable (for non-routing case). 1, 16..991
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

agnVoiceSwConfRtRowStatus 1.3.6.1.4.1.164.3.1.2.9.2.1.9
Status of the row for creating/deleting entries in the table.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER active(1), notInService(2), notReady(3), createAndGo(4), createAndWait(5), destroy(6)  

agnVoiceSwConfHGTable 1.3.6.1.4.1.164.3.1.2.9.5
Table of Hunt Groups.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnVoiceSwConfHGEntry

agnVoiceSwConfHGEntry 1.3.6.1.4.1.164.3.1.2.9.5.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AgnVoiceSwConfHGEntry  

agnVoiceSwConfHGdbIdx 1.3.6.1.4.1.164.3.1.2.9.5.1.1
Active or Temporary Table. Both configurations can be read but only the Temporary can be written to.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER active(1), temporary(255)  

agnVoiceSwConfHGIdx 1.3.6.1.4.1.164.3.1.2.9.5.1.2
There may be up to 10 Hunt Groups per MXcess. That's the index of the hunt group relevant to this row.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..10  

agnVoiceSwConfHGConnect 1.3.6.1.4.1.164.3.1.2.9.5.1.3
This attribute indicates whether the hunt group should be considered in any of the mux algorithms.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

agnVoiceSwConfHGExt 1.3.6.1.4.1.164.3.1.2.9.5.1.4
This is the extension number of the hunt group. 0 is for not valid. The allowed range is 10 - 99.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..99  

agnSigProfileTable 1.3.6.1.4.1.164.3.1.2.10.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnSigProfileEntry

agnSigProfileEntry 1.3.6.1.4.1.164.3.1.2.10.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AgnSigProfileEntry  

agnSigProfileCnfgIdx 1.3.6.1.4.1.164.3.1.2.10.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. The write operation is valid only to the TmpCnfg.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

agnSigProfileIdx 1.3.6.1.4.1.164.3.1.2.10.1.1.2
This attribute indicates the Signaling Profile (1..5).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..5  

agnSigProfileRxTx 1.3.6.1.4.1.164.3.1.2.10.1.1.3
This attribute indicates if the following objects refer to: Rx or Tx translation. Rx : ML->IO Tx : IO->ML .
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER rx(1), tx(2)  

agnSigProfileABCD 1.3.6.1.4.1.164.3.1.2.10.1.1.4
This object represents 6 parameters, by 3 Octets : Busy Code-MSB nibble, - applicable only for Rx translation Idle Code- nibble, - applicable only for Rx translation D Bit Code- nibble, C Bit Code- nibble, B Bit Code- nibble, A Bit Code-LSB nibble. Each of Busy and Idle Code nibble will have the valid values: 0000 .. FFFF. Each of A,B,C,D Bit Code nibble represents: 0 hex = 0000 = 0 1 hex = 0001 = 1 2 hex = 0010 = A bit 3 hex = 0011 = B bit 4 hex = 0100 = C bit 5 hex = 0101 = D bit 6 hex = 0110 = A bit inverse 7 hex = 0111 = B bit inverse 8 hex = 1000 = C bit inverse 9 hex = 1001 = D bit inverse A-F hex - not used (invalid values)
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

mdlSInstTable 1.3.6.1.4.1.164.3.1.3.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MdlSInstEntry

mdlSInstEntry 1.3.6.1.4.1.164.3.1.3.1.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MdlSInstEntry  

mdlSInstSltIdx 1.3.6.1.4.1.164.3.1.3.1.1.1.1
A unique number to identify a slot position in the mux. In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io(16) are not valid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER psA(1), psB(2), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

mdlSInstCardType 1.3.6.1.4.1.164.3.1.3.1.1.1.2
This attribute indicates the type of card installed in the specific slot position. Only PS cards are possible in the PS slots. Only CL cards are possible in the CL slots. Only IO cards are possible in the IO slots.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), empty(2), acm(9), ps60W(10), ps100W(11), cl1(20), clEth(21), cl2(22), cl2Eth(23), cl3(24), cl3Eth(25), mPh1(31), mPh3(32), mPh1T1DSU(33), mPh1T1CSU(34), mPh1E1DSU(35), mPh1E1LTU(36), mPl6(60), mPl3(61), mPv4(72), vf3EandM(80), vf3Fxs(81), vf3Fxo(82), vfPbx(83), vfPbxT1(84), vfPbxE1(85), mtMlF2T1(88), mtMlF2E1(89), mtMlT1Fiber(90), mtMlE1Fiber(91), mtMlT1FiberFb(92), mtMlE1FiberFb(93), mtmlHE1(94), mtmlH1E1(95), mtmlHSE1(96), ml20(97), mtMl4T1(98), mtMl4E1(99), mtMl1T1DSU(100), mtMl1T1CSU(101), mtMl1E1DSU(102), mtMl1E1LTU(103), mtMl1T1DSUfb(104), mtMl1T1CSUfb(105), mtMl1E1DSUfb(106), mtMl1E1LTUfb(107), mtMl2T1(108), mtMl2E1(109), ls2CcittX50(110), ls2CcittX58(111), ls2ATandTSdm(112), ls2ACcittX50(113), ls2ACcittX58(114), ls2AATandTSdm(115), ls2A2Ts(116), ls2M(117), hs2(120), hs3(121), hsq(122), hs703(123), hsQM(124), hsqN(125), hs6(126), hs12(127), hs4T1(130), hs4E1(131), hs4(132), vc2EandM(140), vc2Fxs1Plar(141), vc2Fxo1(142), vc2Fxs2(143), vc2Fxo2(144), vc2Fxs3(145), vc2Fxo3(146), vc26EandM(147), mtvc2(148), vc2R2Fxs(149), hsu(150), mbeA(151), mbeB(152), mbeU(153), tre(154), hsuI(155), hsr(156), hss(157), hsu1(158), ls12(159), ls6(160), ls6V1EandM(161), ls6V1Fxo(162), ls6V1Fxs(163), ls6V2EandM(164), ls6V2Fxo(165), ls6V2Fxs(166), ls6VfEandM(167), ls6VfFxo(168), ls6VfFxs(169), vc3EandM(170), vc3Fxo(171), vc3Fxs(172), vcPbx(173), vcPbxT1(174), vcPbxE1(175), vc6EandM(176), vc6Fxo(177), vc6Fxs(178), vcq(179), mhs1V36(181), mhs1V35(182), mhs1G703(183), mhs1DDS(184), mhs3(185), mhs1X21(186), mhs1V24(187), mhs4(188), mhsE1Hs(189), mhsT1Hs(190), mhsHyE1Hs(191), mhsHyT1Hs(192), mlfHybE1Hs(193), mlfHybT1Hs(194), mhs2e1(195), mhs2t1(196), mhsHy2e1(197), mhsHy2t1(198), mlfHybE12(199), mls6(200), mls3(201), mlfHybT12(204), mvc4(210), mvc4PbxE1(211), mvc4PbxT1Dsu(212), mvc4PbxT1Csu(213), mvc4PbxE1Slave(214), mvc4PbxT1Slave(215), mhsS(220), mhsU(221), mhsPriE1(222), mhsPriT1(223), vc12EandM(230), vc12Fxo(231), vc12Fxs(232), vc6aEandM(233), vc6aFxo(234), vc6aFxs(235), vc6AgFxo(236), vc6AgFxs(237), hsu12(240), hsu6(241), hss12(242), hss6(243), mvg1Lan(253), mvg2Lan(254)  

mdlSHwVersion 1.3.6.1.4.1.164.3.1.3.1.1.1.3
This attribute indicates the Hardware version of the installed card in the specific slot position.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

mdlSSwVersion 1.3.6.1.4.1.164.3.1.3.1.1.1.4
This attribute indicates the Software version of the installed card in the specific slot position.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

mdlSAlrStatus 1.3.6.1.4.1.164.3.1.3.1.1.1.5
Indicates the alarm state at module level, i.e. lower level (port alarms) status is not included. This attribute will be set to: critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(2), event(3), minor(4), major(5), warning(6), critical(7)  

mdlSAlrStatusAll 1.3.6.1.4.1.164.3.1.3.1.1.1.6
Indicates the alarm state in the module-all level, i.e. lower level (port alarms) included. This attribute will be set to: critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(2), event(3), minor(4), major(5), warning(6), critical(7)  

mdlSMaskedAlrStat 1.3.6.1.4.1.164.3.1.3.1.1.1.7
Indicates the alarm state at module level, [i.e. lower level (port alarms) status is not included],including Masked alarms. This attribute will be set to: critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(2), event(3), minor(4), major(5), warning(6), critical(7)  

mdlSMaskedAlrStatAll 1.3.6.1.4.1.164.3.1.3.1.1.1.8
Indicates the alarm state in the module-all level, i.e. lower level (port alarms) included, including Masked alarms. This attribute will be set to: critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(2), event(3), minor(4), major(5), warning(6), critical(7)  

mdlSTstStatusAll 1.3.6.1.4.1.164.3.1.3.1.1.1.9
This attribute will be set to on(3) when there is at least one test in progress on a channel of the card, otherwise the value will be off(2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlSClearAlrCmd 1.3.6.1.4.1.164.3.1.3.1.1.1.10
Setting this command to ON, enforces a clear of all the alarms in the given slot, excluding alarms of port level. The clear operation will not be applied for masked/inverted alarms.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlSClearAllAlrCmd 1.3.6.1.4.1.164.3.1.3.1.1.1.11
Setting this command to ON, enforces a clear of all the alarms in the given slot, including all its ports alarms. The clear operation will not be applied for masked/inverted alarms.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlSAlrTable 1.3.6.1.4.1.164.3.1.3.1.2
The list of card agent alarms ; includes also an alarm indicating existence of alarms on its ports if there are any.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MdlSAlrEntry

mdlSAlrEntry 1.3.6.1.4.1.164.3.1.3.1.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MdlSAlrEntry  

mdlSAlrIdx 1.3.6.1.4.1.164.3.1.3.1.2.1.1
A unique number to identify an entry in the alarm status table. Users should use the get next function to read this table because the indexes are not consecutive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mdlSAlrSltIdx 1.3.6.1.4.1.164.3.1.3.1.2.1.2
This attribute indicates the desired slot position. In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io12(16) are not valid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER psA(1), psB(2), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

mdlSAlrCodeDescription 1.3.6.1.4.1.164.3.1.3.1.2.1.3
This attribute is a full text description of the alarm . The alarm description includes the following information: alarm code, alarm text, alarm severity, Masked or Inverted flag and counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

mdlSAlrCode 1.3.6.1.4.1.164.3.1.3.1.2.1.4
A code identifying the alarm of an entry in the alarm status table at card level.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mdlSAlrSeverity 1.3.6.1.4.1.164.3.1.3.1.2.1.5
The severity of the alarm.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER event(3), minor(4), major(5), warning(6), critical(7)  

mdlSAlrState 1.3.6.1.4.1.164.3.1.3.1.2.1.6
State of the alarm.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlSAlrCounter 1.3.6.1.4.1.164.3.1.3.1.2.1.7
A counter - how many times the alarm occured since last clear operation. ON and OFF Alarm will be counted separately.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mdlSAlrMask 1.3.6.1.4.1.164.3.1.3.1.2.1.8
Alarm mask : on/off.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlSAlrInvert 1.3.6.1.4.1.164.3.1.3.1.2.1.9
Alarm invert : on/off.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlCPrgTable 1.3.6.1.4.1.164.3.1.3.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MdlCPrgEntry

mdlCPrgEntry 1.3.6.1.4.1.164.3.1.3.2.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MdlCPrgEntry  

mdlCCnfgIdx 1.3.6.1.4.1.164.3.1.3.2.1.1.1
This attribute indicates the Idx of the Cnfg(1..100) being referred. Value 255 specifies the TmpCnfg
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

mdlCSltIdx 1.3.6.1.4.1.164.3.1.3.2.1.1.2
This attribute indicates a unique number of the slot position where the card is inserted. In the ?004 Unit the entries psB(2),clB(4),io6(10)..io(16) are not valid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER psA(1), psB(2), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

mdlCPrgCardType 1.3.6.1.4.1.164.3.1.3.2.1.1.3
This attribute indicates the type of card assigned to the specific slot in the common configuration. This object is identical in all the configurations (1..100). Only the TmpCnf(255) may have different value. The write operation is valid only to the TmpCnfg entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), empty(2), acm(9), ps48x60W(10), ps48x100W(11), ps110x60W(12), ps110x100W(13), ps220x60W(14), ps220x100W(15), ps180W(16), cl1(20), clEth(21), cl2(22), cl2Eth(23), cl3(24), cl3Eth(25), mPh1(31), mPh3(32), mPh1T1DSU(33), mPh1T1CSU(34), mPh1E1DSU(35), mPh1E1LTU(36), mPl6(60), vf3EandM(80), vf3Fxs(81), vf3Fxo(82), vfPbx(83), vfPbxT1(84), vfPbxE1(85), mtMlF2T1(88), mtMlF2E1(89), mtMlT1Fiber(90), mtMlE1Fiber(91), mtMlT1FiberFb(92), mtMlE1FiberFb(93), mtmlHE1(94), mtmlH1E1(95), mtmlHSE1(96), ml20(97), mtMl4T1(98), mtMl4E1(99), mtMl1T1DSU(100), mtMl1T1CSU(101), mtMl1E1DSU(102), mtMl1E1LTU(103), mtMl1T1DSUfb(104), mtMl1T1CSUfb(105), mtMl1E1DSUfb(106), mtMl1E1LTUfb(107), mtMl2T1(108), mtMl2E1(109), ls2CcittX50(110), ls2CcittX58(111), ls2ATandTSdm(112), ls2ACcittX50(113), ls2ACcittX58(114), ls2AATandTSdm(115), ls2A2Ts(116), ls2M(117), hs2(120), hs3(121), hsq(122), hs703(123), hsQM(124), hsqN(125), hs6(126), hs12(127), hs4T1(130), hs4E1(131), vc2EandM(140), vc2Fxs1Plar(141), vc2Fxo1(142), vc2Fxs2(143), vc2Fxo2(144), vc2Fxs3(145), vc2Fxo3(146), vc26EandM(147), mtvc2(148), vc2R2Fxs(149), hsu(150), mbeA(151), mbeB(152), mbeU(153), tre(154), hsuI(155), hsr(156), hss(157), hsu1(158), ls12(159), ls6(160), ls6V1EandM(161), ls6V1Fxo(162), ls6V1Fxs(163), ls6V2EandM(164), ls6V2Fxo(165), ls6V2Fxs(166), ls6VfEandM(167), ls6VfFxo(168), ls6VfFxs(169), vc3EandM(170), vc3Fxo(171), vc3Fxs(172), vcPbx(173), vcPbxT1(174), vcPbxE1(175), vc6EandM(176), vc6Fxo(177), vc6Fxs(178), vcq(179), mhs1V36(181), mhs1V35(182), mhs1G703(183), mhs1DDS(184), mhs3(185), mhs1X21(186), mhs1V24(187), mhs4(188), mhsE1Hs(189), mhsT1Hs(190), mhsHyE1Hs(191), mhsHyT1Hs(192), mlfHybE1Hs(193), mlfHybT1Hs(194), mhs2e1(195), mhs2t1(196), mhsHy2e1(197), mhsHy2t1(198), mlfHybE12(199), mls6(200), mls3(201), mlfHybT12(204), mvc4(210), mvc4PbxE1(211), mvc4PbxT1Dsu(212), mvc4PbxT1Csu(213), mvc4PbxE1Slave(214), mvc4PbxT1Slave(215), mhsS(220), mhsU(221), mhsPriE1(222), mhsPriT1(223), vc12EandM(230), vc12Fxo(231), vc12Fxs(232), vc6aEandM(233), vc6aFxo(234), vc6aFxs(235), vc6AgFxo(236), vc6AgFxs(237), hsu12(240), hsu6(241), hss12(242), hss6(243), mvg1Lan(253), mvg2Lan(254)  

mdlCNoOfExternPrt 1.3.6.1.4.1.164.3.1.3.2.1.1.4
Number of external ports in the programmed card of the specific slot position
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mdlCNoOfInternPrt 1.3.6.1.4.1.164.3.1.3.2.1.1.5
Number of internal ports in the programmed card of the specific slot position.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mdlCmprTable 1.3.6.1.4.1.164.3.1.3.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MdlCmprEntry

mdlCmprEntry 1.3.6.1.4.1.164.3.1.3.3.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MdlCmprEntry  

mdlCmprTypIdx 1.3.6.1.4.1.164.3.1.3.3.1.1.1
This attribute indicates the Type of the Compressed being referred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mdlCmprCnfgIdx 1.3.6.1.4.1.164.3.1.3.3.1.1.2
This attribute indicates the configuration to which the Compressed information is related.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mdlCmprVersion 1.3.6.1.4.1.164.3.1.3.3.1.1.3
This attribute indicates the version of the internal format of the Compressed data
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mdlCmprSltIdx 1.3.6.1.4.1.164.3.1.3.3.1.1.4
This attribute indicates a unique number of the slot position where the card is inserted. In the ?004 Unit the entries psB(2),clB(4),io6(10)..io(16) are not valid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER psA(1), psB(2), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

mdlCmprObj 1.3.6.1.4.1.164.3.1.3.3.1.1.5
This attribute is the compressed information itself.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

mdlAlarmsCmprTable 1.3.6.1.4.1.164.3.1.3.3.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MdlAlarmsCmprEntry

mdlAlarmsCmprEntry 1.3.6.1.4.1.164.3.1.3.3.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MdlAlarmsCmprEntry  

mdlAlarmsCmprVersion 1.3.6.1.4.1.164.3.1.3.3.2.1.1
This attribute indicates the version of the internal format of the Compressed data
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mdlAlarmsCmprAlarmSlot 1.3.6.1.4.1.164.3.1.3.3.2.1.2
This attribute indicates the desired slot position. In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io(16) are not valid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mdlAlarmsCmprAlarmIdx 1.3.6.1.4.1.164.3.1.3.3.2.1.3
A unique number to identify an entry in the alarm status table of the agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mdlAlarmsCmprObj 1.3.6.1.4.1.164.3.1.3.3.2.1.4
This attribute is the compressed information itself.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

prtSInstTable 1.3.6.1.4.1.164.3.1.4.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtSInstEntry

prtSInstEntry 1.3.6.1.4.1.164.3.1.4.1.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtSInstEntry  

prtSInstSltIdx 1.3.6.1.4.1.164.3.1.4.1.1.1.1
This attribute indicates a unique number to identify the slot where the card is inserted. In the ?004 Unit the entries io6(10)..io(16) are not valid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtSInstPrtIdx 1.3.6.1.4.1.164.3.1.4.1.1.1.2
This attribute indicates a unique number to identify a port in a specific card. The valid ports depend on the installed card: the valid external ports (interfaces) are (1..mdlCNoOfExternPrt) if any, and the valid internal ports are (101..100+mdlCNoOfInternPrt) if any. Generally: exPrt1 (1) .. exPrt12 (12), inPrt14 (114) .. inPrt48 (148)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtSInstPrtType 1.3.6.1.4.1.164.3.1.4.1.1.1.3
This attribute describes the type of the designated port. In MX 3000 only external & internal options are used. All the other options are only for MX 30/300 which need special handling. In order to support interface types in MX 3000, return an ascii string for prtSInterfaceType in this table or support the general RAD value of physicalConnector. External port - is a port with a physical connector. Internal port - might be of two types: a) A composite port which collects a few external ports data into a common bandwidth (usually routed through DS1 link) b) A port which gets only part of the external ports (usually a few DS0's) The following types are used when all ports are external/ internal and the connector/interface type is necessary (for example, stand-alone units): High Speed port types Low Speed port types Voice port types, CL port types.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER external(2), internal(3), highSpeedV35(4), highSpeedV24(5), highSpeedV36(6), highSpeedX21(7), highSpeedG703(8), highSpeedDDS(9), lowSpeed(10), voice(11), cl(12), isdns(13), isdnu(14), ethernet(15), voiceS0(16)  

prtSInstIfIndex 1.3.6.1.4.1.164.3.1.4.1.1.1.4
This attribute indicates the unique interface number assigned to the port. The specific interface of this attribute is the same as the interface identified by the value of ifindex in MIB-II.If there is no interface for the specific prtIdx the value will be '7fffffff'h.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtSActiveStatus 1.3.6.1.4.1.164.3.1.4.1.1.1.5
This attribute describes the activity status of the port. unknown(1) indicates that the information is not supported. notUsed(2) indicates that the ch is not connected according to the active config. offLine(3) indicates that the ch is down (not working) because of any problem. onLine(4) indicates that the ch is up (working) offLineRedundancy(5) indicates that the ch is down, because it is redundant port. onLineRedundancy(6) indicates that the ch is up, and it is the active link
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), notUsed(2), offLine(3), onLine(4), offLineRedundancy(5), onLineRedundancy(6)  

prtSAlrStatus 1.3.6.1.4.1.164.3.1.4.1.1.1.6
Indicates the alarm state in the port(ch) agent level. This attribute will be set to: critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(2), event(3), minor(4), major(5), warning(6), critical(7)  

prtSMaskedAlrStat 1.3.6.1.4.1.164.3.1.4.1.1.1.7
Indicates the alarm state in the port(ch) agent level, including Masked alarms. This attribute will be set to: critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(2), event(3), minor(4), major(5), warning(6), critical(7)  

prtSClearAlrCmd 1.3.6.1.4.1.164.3.1.4.1.1.1.8
Setting this attribute to on(3) enforces a clear operation of the alarm status events in the given port. The clear operation will not be applied for masked/inverted alarms.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtSTestMask 1.3.6.1.4.1.164.3.1.4.1.1.1.9
This is a mask which indicates which tests from the 'prtSTstCmd' list are allowed for the requested port. If a specific test is allowed, its respective bit will be SET in the mask : TEST BIT ----------- --- local-loop 1 remote-loop 2 loc-and-rem-main-loops 3 remote-analog-loop 4 remote-digital-loop 5 rem-loop-on-ext-unit 6 bert 7 tone-injection 8 dlci local-loop 9 all dlci local-loop 10 dlci remote-loop 11 all dlci remote-loop 12 bert-and-rem-loop-on-rem-unit 13 rem-loop-on-rem-unit 14 block 15 backward-tone-inject 16 llb 17 rlb 18 ft1Enable 21 lbbd 22 --for 2B+D lb1 23 --for B1 lb2 24 --for B2 e.g : If the return value is 3 -> 0000000000000011 -> Bits 1 & 2 are set -> the allowed tests are : local-loop remote-loop
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtSTstCmd 1.3.6.1.4.1.164.3.1.4.1.1.1.10
Setting this attribute to any of the above values will initiate a test on the specific port if the operation is legal. If the operation is not legal, the mux will ignore the operation. If a test time out is needed, the test will be set with a default timeout of 2 minutes until the user will set the parameter 'prtSTstDuration' to the required time out. If no time out is needed , the test will be set with infinite timeout until the user will set the parameter 'prtSTstDuration' to the required time out.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), localLoop(2), remoteLoop(3), locAndRemMainLoops(4), remoteAnalogLoop(5), remoteDigitalLoop(6), remLoopOnExtUnit(7), bert(8), toneInjection(9), dlciLocalLoop(10), allDlciLocalLoop(11), dlciRemoteLoop(12), allDlciRemoteLoop(13), extInitLocalLoop(14), bertAndRemLoopOnRemUnit(15), remLoopOnRemUnit(16), block(17), backwardToneInject(18), llb(19), rlb(20), ft1Enable(21), lbbd(22), lb1(23), lb2(24)  

prtSTstDuration 1.3.6.1.4.1.164.3.1.4.1.1.1.11
This attribute indicates the maximum duration of executing a test on the specific port. This entry applies to all the test operations. The resolution will be a minute, and the maximum duration is limited to 30 minutes . A zero value specifies no time limitation. When the test isn't active, the agent initiates this object to 2 when the duration is needed and to 0 if its not required. The user should set this parameter after setting the 'prtSTstCmd' parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

prtSBertClrCmd 1.3.6.1.4.1.164.3.1.4.1.1.1.12
Setting this attribute initiates bert count clear operation. It is valid only when bert test is active on the specific port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtSBertTstRslt 1.3.6.1.4.1.164.3.1.4.1.1.1.13
This attribute indicates the number of Bit Error Rate indicated during the BERT operation. It is valid only when bert test is active on the specific port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtSInterfaceType 1.3.6.1.4.1.164.3.1.4.1.1.1.14
This attribute indicates a unique HW interface type of the selected port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

prtSParamStatus 1.3.6.1.4.1.164.3.1.4.1.1.1.15
This object indicates Status of parameters specific to the selected port. - For a port that has no special status or is supported by prtSExHsfStatTable - 1 Octet: 00hex - For VC-6, VC-12, VC-12/6 external ports - 1 Octet : Bit 7 (MSB)..Bit 2 = 0 (NA) Bit 1: Tx Signaling '1'=On ; '0'=Off Bit 0 (LSB): Rx Signaling '1'=On ; '0'=Off - For VC-6A and VC-6AG external ports - 1 Octet : Bit 7 (MSB)..Bit 3 = 0 (NA) Bit 2: ADPCM module '1' =Exist ; '0' =Not Exist Bit 1: Tx Signaling '1'=On ; '0'=Off Bit 0 (LSB): Rx Signaling '1'=On ; '0'=Off - For VC-2/R2(FXS) external ports - 1 Octet : Bit - 7 6 5 4 3 2 1 0 |_| |_________| Call Call State Direction Bit 7 (MSB) and Bit 6 : Call Direction 00 - Incoming 01 - Outgoing Bit 5..Bit 0: Call State 000000 - Idle 000001 - Seized 000010 - Both-Way Conflict 000011 - Seizure Ack 000100 - Answered 000101 - Clear Backward 000110 - Clear Forward 000111 - Blocked 001000 - Fault 001001 - Fault 3 001010 - Fault 4 001011 - Fault 5 001100 - Fault 6 001101 - Fault 7 - For ML-20 external port - 3 Octets : - 1 MS Octet will represent the Real Rate used: Bit - 7 6 5 4 3 2 1 0 |___| |_______| spare Rate Valid values: 0..31, meaning 0..31x64Kbps Invalid values: 32..255. - 2 LS Octets will represent the Status of 7 Control Signals: Signal - --- CTS DSR DCD RJ TM DTR RTS Bit - 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Octet - 2 3 (LS) '---' will always have the value 00 Rest of the Signals (2 bits each) can have the following values: 00=NA ; 01=unused ; 10=Off ; 11=On - For ML-H/E1, ML-H/1/E1, ML-H/S/E1 internal port - 1 Octet Bit - 7 6 5 4 3 2 1 0 |___________| spare Mode of Operation Mode of Operation: '1'=Central ; '0'=Remote - For ACM external port - 1 Octet Bit - 7 6 5 4 3 2 1 0 |_________| spare Alarm State Alarm State: according to bits 1,0: 00=NA ; 01=unused ; 10=Off ; 11=On - For HS-U/1 external port - 1 Octet Bit 7 6 5 4 3 2 1 0 LSB |________| |__| |__| spare modem sync modem: 00 = unknown sync: 00 = not sync 01 = ASMi-31 01 = sync 10 = other 10 = reserved 11 = reserved 11 = reserved
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

prtSAlrTable 1.3.6.1.4.1.164.3.1.4.1.2
The list of port agent alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtSAlrEntry

prtSAlrEntry 1.3.6.1.4.1.164.3.1.4.1.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtSAlrEntry  

prtSAlrIdx 1.3.6.1.4.1.164.3.1.4.1.2.1.1
A unique number to identify an entry in the alarm status table. Users should use the get next function to read this table because the indexes are not consecutive
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtSAlrSltIdx 1.3.6.1.4.1.164.3.1.4.1.2.1.2
This attribute indicates a unique identifier of the slot where the card is inserted. In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io12(16) are not valid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER psA(1), psB(2), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtSAlrPrtIdx 1.3.6.1.4.1.164.3.1.4.1.2.1.3
This attribute indicates a unique identifier of the port the alarm applies to. All the values are valid. No alarms exist for a port which does not physically exist. Valid values: exPrt1 (1) .. exPrt12 (12) , inPrt1 (101) .. inPrt48 (148).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtSAlrCodeDescription 1.3.6.1.4.1.164.3.1.4.1.2.1.4
This attribute is a full text description of the alarm. The alarm description includes the following information: alarm code, alarm text, alarm severity, Masked or Inverted flag and counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

prtSAlrCode 1.3.6.1.4.1.164.3.1.4.1.2.1.5
A code identifying the alarm of an entry in the alarm status table at port level.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtSAlrSeverity 1.3.6.1.4.1.164.3.1.4.1.2.1.6
The severity of the alarm.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER event(3), minor(4), major(5), warning(6), critical(7)  

prtSAlrState 1.3.6.1.4.1.164.3.1.4.1.2.1.7
State of the alarm.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtSAlrCounter 1.3.6.1.4.1.164.3.1.4.1.2.1.8
A counter - how many times the alarm occured since last clear operation. ON and OFF Alarm will be counted separately.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtSAlrMask 1.3.6.1.4.1.164.3.1.4.1.2.1.9
Alarm mask : on/off.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtSAlrInvert 1.3.6.1.4.1.164.3.1.4.1.2.1.10
Alarm invert : on/off.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

statisPrtGen 1.3.6.1.4.1.164.3.1.4.1.3
OBJECT IDENTIFIER    

prtFrStatis 1.3.6.1.4.1.164.3.1.4.1.3.1
OBJECT IDENTIFIER    

prtCrStatis 1.3.6.1.4.1.164.3.1.4.1.3.2
OBJECT IDENTIFIER    

prtDlciStatis 1.3.6.1.4.1.164.3.1.4.1.3.3
OBJECT IDENTIFIER    

prtT1Statis 1.3.6.1.4.1.164.3.1.4.1.3.4
OBJECT IDENTIFIER    

prtFrStatisTable 1.3.6.1.4.1.164.3.1.4.1.3.1.1
This table is applicable only for an active port running an FR protocol .
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtFrStatisEntry

prtFrStatisEntry 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtFrStatisEntry  

prtFrStatisSltIdx 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.1
This attribute indicates a unique slot position where the module is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid. For stand-alone units this index will be notApplicable (255).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtFrStatisPrtIdx 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.2
This attribute indicates a unique port number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6)  

prtFrStatisInvIdx 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.3
The Interval of 15 min. for which the following statistics counters are applicable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER currentInv(1), last(2)  

prtFrTimeElapsed 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.4
The number of seconds that have elapsed since the beginning of the current error-measurement interval. This object is applicable mainly for the current interval. For other interval: - if data is available: value will be 899. - if data is not available: value will be 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..899  

prtFrRxTotalFrames 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.5
The total number of frames received by this port during the selected interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

prtFrTxTotalFrames 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.6
The total number of frames sent by this port during the selected interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

prtFrRxTotalBytes 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.7
The total number of bytes received by this port during the selected interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

prtFrTxTotalBytes 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.8
The total number of bytes sent by this port during the selected interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

prtFrRxMngFrames 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.9
The management number of frames received by this port during the selected interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

prtFrTxMngFrames 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.10
The management number of frames sent by this port during the selected interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

prtFrRxDeFrames 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.11
The number of De frames received by this port during the selected interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

prtFrTxDeFrames 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.12
The number of De frames sent by this port during the selected interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

prtFrRxDcrdCongDeFr 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.13
The number of De frames discarded due to congestion, received by this port during the selected interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

prtFrTxDcrdCongDeFr 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.14
The number of De frames discarded due to congestion, sent by this port during the selected interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

prtFrRxDcrdCongAllFr 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.15
All the frames discarded due to congestion, received by this port during the selected interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

prtFrTxDcrdCongAllFr 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.16
All the frames discarded due to congestion, sent by this port during the selected interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

prtFrRxFecn 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.17
Number of frames received by this port during the selected interval, indicating forward congestion.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

prtFrTxFecn 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.18
Number of frames sent by this port during the selected interval, indicating forward congestion.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

prtFrRxBecn 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.19
Number of frames received by this port during the selected interval, indicating backward congestion.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

prtFrTxBecn 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.20
Number of frames sent by this port during the selected interval, indicating backward congestion.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

prtFrRxBeViol 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.21
Number of data frames received by this port during the selected interval, exceeding the Burst Excess value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

prtFrTxBeViol 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.22
Number of data frames sent by this port during the selected interval, exceeding the Burst Excess value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

prtFrRxBcViol 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.23
Number of data frames received by this port during the selected interval, exceeding the Burst Committed value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

prtFrTxBcViol 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.24
Number of data frames sent by this port during the selected interval, exceeding the Burst Committed value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

prtCrStatisTable 1.3.6.1.4.1.164.3.1.4.1.3.2.1
This table is applicable only for an active port running a CR protocol .
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtCrStatisEntry

prtCrStatisEntry 1.3.6.1.4.1.164.3.1.4.1.3.2.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtCrStatisEntry  

prtCrStatisSltIdx 1.3.6.1.4.1.164.3.1.4.1.3.2.1.1.1
This attribute indicates a unique slot position where the module is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid. For stand-alone units this index will be notApplicable (255).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtCrStatisPrtIdx 1.3.6.1.4.1.164.3.1.4.1.3.2.1.1.2
This attribute indicates a unique port number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6)  

prtCrStatisInvIdx 1.3.6.1.4.1.164.3.1.4.1.3.2.1.1.3
The Interval of 15 min. for which the following statistics counters are applicable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER currentInv(1), last(2)  

prtCrTimeElapsed 1.3.6.1.4.1.164.3.1.4.1.3.2.1.1.4
The number of seconds that have elapsed since the beginning of the current error-measurement interval. This object is applicable mainly for the current interval. For other interval: - if data is available: value will be 899. - if data is not available: value will be 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..899  

prtCrRxTotalCells 1.3.6.1.4.1.164.3.1.4.1.3.2.1.1.5
The total number of cells received by this port during the selected interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

prtCrTxTotalCells 1.3.6.1.4.1.164.3.1.4.1.3.2.1.1.6
The total number of cells sent by this port during the selected interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

prtCrRxDataCells 1.3.6.1.4.1.164.3.1.4.1.3.2.1.1.7
The number of Data Cells received by this port during the selected interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

prtCrTxDataCells 1.3.6.1.4.1.164.3.1.4.1.3.2.1.1.8
The number of Data Cells sent by this port during the selected interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

prtDlciStatisTable 1.3.6.1.4.1.164.3.1.4.1.3.3.1
This table is applicable only for an active port running an FR, FR+ or CR protocol, with valid DLCIs .
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtDlciStatisEntry

prtDlciStatisEntry 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtDlciStatisEntry  

prtDlciSltIdx 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.1
This attribute indicates a unique slot position where the module is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid. For stand-alone units this index will be notApplicable (255).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtDlciPrtIdx 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.2
This attribute indicates a unique port number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6)  

prtDlciIdx 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.3
This attribute indicates a unique DLCI index for each valid DLCI (16..991).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..991  

prtDlciRxDeFrames 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.4
The number of De frames received by this DLCI.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

prtDlciTxDeFrames 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.5
The number of De frames sent by this DLCI.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

prtDlciRxDcrdCongDeFr 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.6
The number of De frames discarded due to congestion, received by this DLCI.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

prtDlciTxDcrdCongDeFr 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.7
The number of De frames discarded due to congestion, sent by this DLCI.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

prtDlciRxDcrdCongAllFr 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.8
All the frames discarded due to congestion, received by this DLCI.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

prtDlciTxDcrdCongAllFr 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.9
All the frames discarded due to congestion, sent by this DLCI.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

prtDlciTxFecn 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.10
Number of frames sent by this DLCI, indicating forward congestion.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

prtDlciTxBecn 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.11
Number of frames sent by this DLCI, indicating backward congestion.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

prtDlciRxBeViol 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.12
Number of data frames received by this DLCI, exceeding the Burst Excess value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

prtDlciTxBeViol 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.13
Number of data frames sent by this DLCI, exceeding the Burst Excess value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

prtDlciRxBcViol 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.14
Number of data frames received by this DLCI, exceeding the Burst Committed value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

prtDlciTxBcViol 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.15
Number of data frames sent by this DLCI, exceeding the Burst Committed value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

prtT1FdlMsgTable 1.3.6.1.4.1.164.3.1.4.1.3.4.1
This table is applicable for a T1 interface with 'esf' LineType .
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtT1FdlMsgEntry

prtT1FdlMsgEntry 1.3.6.1.4.1.164.3.1.4.1.3.4.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtT1FdlMsgEntry  

prtT1FdlMsgSltIdx 1.3.6.1.4.1.164.3.1.4.1.3.4.1.1.1
This attribute indicates a unique slot position where the module is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtT1FdlMsgPrtIdx 1.3.6.1.4.1.164.3.1.4.1.3.4.1.1.2
This attribute indicates a unique port number. MTML-1/T1 modules have just one external interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1)  

prtT1FdlMsgFdlTxRx 1.3.6.1.4.1.164.3.1.4.1.3.4.1.1.3
The Fdl tx/rx reference of the Fdl message.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER tx(1), rx(2)  

prtT1FdlMsg 1.3.6.1.4.1.164.3.1.4.1.3.4.1.1.4
FDL message.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

prtExTsSplitTable 1.3.6.1.4.1.164.3.1.4.2.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExTsSplitEntry

prtExTsSplitEntry 1.3.6.1.4.1.164.3.1.4.2.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtExTsSplitEntry  

prtExTsCnfgIdx 1.3.6.1.4.1.164.3.1.4.2.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtExTsSltIdx 1.3.6.1.4.1.164.3.1.4.2.1.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid. notApplicable - for stand-alone units.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExTsPrtIdx 1.3.6.1.4.1.164.3.1.4.2.1.1.3
This attribute indicates a unique port number. Most ML cards have only one external interface. inPrt1 - for MTML-H/E1 cards. For other products' index see their specification.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtExTsIdx 1.3.6.1.4.1.164.3.1.4.2.1.1.4
This attribute indicates a unique time slot position. The valid time slots are: 1..24 for T1 Card and 1..31 for E1 interface. In G732S-E1 lines, time slot 16 is not valid for data, it is dedicated to multiframe synchronization bits and voice signaling.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtExTsBit 1.3.6.1.4.1.164.3.1.4.2.1.1.5
This attribute indicates a unique Bit within the time slot. The valid Bits are: 1..8.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..8  

prtExTsIConSlot 1.3.6.1.4.1.164.3.1.4.2.1.1.6
This attribute indicates whether the specified time slot is connected/routed internally in the Agent and to which card it is connected. In the ?004 Unit the entries io6(10)..io12(16) are not valid. notApplicable - for stand-alone units.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noConnect(2), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExTsIConPrt 1.3.6.1.4.1.164.3.1.4.2.1.1.7
This attribute indicates the internally (In Mux) connected/routed port. For other products' index see their specification.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

prtCnfgAgenda 1.3.6.1.4.1.164.3.1.4.2.2
OBJECT IDENTIFIER    

prtAgendaBehaviourTable 1.3.6.1.4.1.164.3.1.4.2.2.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtAgendaBehaviourEntry

prtAgendaBehaviourEntry 1.3.6.1.4.1.164.3.1.4.2.2.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtAgendaBehaviourEntry  

prtAgendaBehaviourCnfgIdx 1.3.6.1.4.1.164.3.1.4.2.2.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtAgendaBehaviourSltIdx 1.3.6.1.4.1.164.3.1.4.2.2.1.1.2
This parameter should be: - slot number for MX3000 - 255 = N/A for MX300/30.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtAgendaBehaviourPrtIdx 1.3.6.1.4.1.164.3.1.4.2.2.1.1.3
This parameter should be: - port number for MX300/30 - 100 = N/A for MX3000.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtAgendaBehaviourOnOff 1.3.6.1.4.1.164.3.1.4.2.2.1.1.4
Setting this command to on(3) enables the agenda function at module (3000) or port (300/30) level.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3)  

prtCnfgAgendaTable 1.3.6.1.4.1.164.3.1.4.2.2.2
This table allows the user to schedule the time a session is active per week basis.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtCnfgAgendaEntry

prtCnfgAgendaEntry 1.3.6.1.4.1.164.3.1.4.2.2.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtCnfgAgendaEntry  

prtCnfgAgendaCnfgIdx 1.3.6.1.4.1.164.3.1.4.2.2.2.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtCnfgAgendaSltIdx 1.3.6.1.4.1.164.3.1.4.2.2.2.1.2
This attribute is equal to: -slot number for MX3000 -255 = N/A for MX300/30
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtCnfgAgendaPrtIdx 1.3.6.1.4.1.164.3.1.4.2.2.2.1.3
This attribute is equal to: -port number for MX300/30 -100 = N/A for MX3000
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtCnfgAgendaDayIdx 1.3.6.1.4.1.164.3.1.4.2.2.2.1.4
This attribute for which day of the week this row applies.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER monday(1), tuesday(2), wednesday(3), thursday(4), friday(5), saturday(6), sunday(7)  

prtCnfgAgendaSesId 1.3.6.1.4.1.164.3.1.4.2.2.2.1.5
The user may define 4 different active intervals per day.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

prtCnfgAgendaFrom 1.3.6.1.4.1.164.3.1.4.2.2.2.1.6
Start from time interval in seconds.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..86400  

prtCnfgAgendaTo 1.3.6.1.4.1.164.3.1.4.2.2.2.1.7
To time interval in seconds.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..86400  

prtGenCnfgTable 1.3.6.1.4.1.164.3.1.4.2.3
This table allows the user to configure general port parameters.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtGenCnfgEntry

prtGenCnfgEntry 1.3.6.1.4.1.164.3.1.4.2.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtGenCnfgEntry  

prtGenCnfgIdx 1.3.6.1.4.1.164.3.1.4.2.3.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. The write operation is valid only to the TmpCnfg.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtGenCnfgSltIdx 1.3.6.1.4.1.164.3.1.4.2.3.1.2
This attribute indicates a unique slot position where the card is inserted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtGenCnfgPrtIdx 1.3.6.1.4.1.164.3.1.4.2.3.1.3
This attribute indicates a unique external or internal port number. For MP: exPrt1 (1) .. exPrt12 (12) , notApplicable(100), inPrt1 (101) .. inPrt48 (148)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtGenCnfgLinkToSlot 1.3.6.1.4.1.164.3.1.4.2.3.1.4
This attribute indicates the slot of the ML card to which the IO port is mapped.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtGenCnfgLinkToPort 1.3.6.1.4.1.164.3.1.4.2.3.1.5
This attribute indicates the port in the prtGenCnfgLinkToSlot of the ML card to which the IO port is mapped. For MP: exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , inPrt1 (101) notApplicable (255)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

prtGenCnfgPortId 1.3.6.1.4.1.164.3.1.4.2.3.1.6
IO Port Id for V5.1 use. This object is applicable only for part of the PSTN and ISDN IO ports. Generally, 0 is a valid value. Nevertheless, for ports that do not support this object, the value will be: notApplicable= 0
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..16777215  

prtCmprTable 1.3.6.1.4.1.164.3.1.4.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtCmprEntry

prtCmprEntry 1.3.6.1.4.1.164.3.1.4.3.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtCmprEntry  

prtCmprTypIdx 1.3.6.1.4.1.164.3.1.4.3.1.1.1
This attribute indicates the Type of the Compressed being referred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtCmprCnfgIdx 1.3.6.1.4.1.164.3.1.4.3.1.1.2
This attribute indicates the configuration to which the Compressed information is related.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtCmprVersion 1.3.6.1.4.1.164.3.1.4.3.1.1.3
This attribute indicates the version of the internal format of the Compressed data
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtCmprSltIdx 1.3.6.1.4.1.164.3.1.4.3.1.1.4
This attribute indicates a unique number of the slot position where the card is inserted. In the ?004 Unit the entries psB(2),clB(4),io6(10)..io(16) are not valid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER psA(1), psB(2), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtCmprPrtIdx 1.3.6.1.4.1.164.3.1.4.3.1.1.5
This attribute indicates a unique identifier of the port the compressed information relates to. Valid values: exPrt1 (1) .. exPrt12 (12) , inPrt1 (101) .. inPrt48 (148).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtCmprObj 1.3.6.1.4.1.164.3.1.4.3.1.1.6
This attribute is the compressed information itself.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

prtDlciCmprTable 1.3.6.1.4.1.164.3.1.4.3.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtDlciCmprEntry

prtDlciCmprEntry 1.3.6.1.4.1.164.3.1.4.3.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtDlciCmprEntry  

prtDlciCmprCnfgIdx 1.3.6.1.4.1.164.3.1.4.3.2.1.1
This attribute indicates the configuration to which the Compressed information is related.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtDlciCmprVersion 1.3.6.1.4.1.164.3.1.4.3.2.1.2
This attribute indicates the version of the internal format of the Compressed data
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtDlciCmprSltIdx 1.3.6.1.4.1.164.3.1.4.3.2.1.3
This attribute indicates a unique number of the slot position where the module is inserted. In the ?004 Unit the entries psB(2),clB(4),io6(10)..io(16) are not valid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtDlciCmprPrtIdx 1.3.6.1.4.1.164.3.1.4.3.2.1.4
This attribute indicates a unique identifier of the port the compressed information relates to. All the values are valid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), exPrt9(9), exPrt10(10), inPrt1(101), inPrt2(102), inPrt3(103), inPrt4(104), inPrt5(105), inPrt6(106), inPrt7(107), inPrt8(108), inPrt9(109), inPrt10(110), inPrt11(111), inPrt12(112)  

prtDlciCmprDlciIdx 1.3.6.1.4.1.164.3.1.4.3.2.1.5
This attribute indicates a unique identifier of the Dlci the compressed information relates to. The values are between 16 - 991.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtDlciCmprObj 1.3.6.1.4.1.164.3.1.4.3.2.1.6
This attribute is the compressed information itself.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

prtAlarmsCmprTable 1.3.6.1.4.1.164.3.1.4.3.3
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtAlarmsCmprEntry

prtAlarmsCmprEntry 1.3.6.1.4.1.164.3.1.4.3.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtAlarmsCmprEntry  

prtAlarmsCmprVersion 1.3.6.1.4.1.164.3.1.4.3.3.1.1
This attribute indicates the version of the internal format of the Compressed data
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtAlarmsCmprAlarmSlot 1.3.6.1.4.1.164.3.1.4.3.3.1.2
This attribute indicates the desired slot position. In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io(16) are not valid. For Stand-alone units, notApplicable(255) will appear.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtAlarmsCmprAlarmPort 1.3.6.1.4.1.164.3.1.4.3.3.1.3
This attribute indicates a unique identifier of the port the alarm applies to. All the values are valid. No alarms exist for a non-physical port
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtAlarmsCmprAlarmIdx 1.3.6.1.4.1.164.3.1.4.3.3.1.4
A unique number to identify an entry in the alarm status table of the agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtAlarmsCmprObj 1.3.6.1.4.1.164.3.1.4.3.3.1.5
This attribute is the compressed information itself.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

prtSExHsfStatTable 1.3.6.1.4.1.164.3.2.3.1.6
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtSExHsfStatEntry

prtSExHsfStatEntry 1.3.6.1.4.1.164.3.2.3.1.6.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtSExHsfStatEntry  

prtSExHsfSltIdx 1.3.6.1.4.1.164.3.2.3.1.6.1.1
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtSExHsfPrtIdx 1.3.6.1.4.1.164.3.2.3.1.6.1.2
This attribute indicates a unique port number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), exPrt9(9), exPrt10(10), exPrt11(11), exPrt12(12)  

prtSExHsfInterfaceTyp 1.3.6.1.4.1.164.3.2.3.1.6.1.3
This attribute indicates a unique interface type of a selected port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), v35(2), rs422(3)  

prtSExHsfRts 1.3.6.1.4.1.164.3.2.3.1.6.1.4
This attribute indicates a unique RTS control signal state.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), notActive(2), active(3)  

cnfgMdlMux 1.3.6.1.4.1.164.3.2.2.1
OBJECT IDENTIFIER    

mdlPbxFramerCnfg 1.3.6.1.4.1.164.3.2.2.1.1
OBJECT IDENTIFIER    

mdlPbxFramerCnfgTable 1.3.6.1.4.1.164.3.2.2.1.1.1
This table contains parameters relevant to a module belonging to a digital voice system, except mdlPbxFraEnhEcho which is relevant also for analog cards.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MdlPbxFramerCnfgEntry

mdlPbxFramerCnfgEntry 1.3.6.1.4.1.164.3.2.2.1.1.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MdlPbxFramerCnfgEntry  

mdlPbxFraCnfgIdx 1.3.6.1.4.1.164.3.2.2.1.1.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mdlPbxFraSltIdx 1.3.6.1.4.1.164.3.2.2.1.1.1.1.2
The slot relevant to this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

mdlPbxFraEnhEcho 1.3.6.1.4.1.164.3.2.2.1.1.1.1.3
Refers to external ports of an analogue module and to the internal ports of the other mvc4 types of modules. ms16(3) means that the four voice ports have enhanced echo of 16ms. ms32(4) means that the two first ports have enhanced echo of 32 ms while the last two ports have no enhanced echo.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), ms16(3), ms32(4)  

mdlPbxFraTSGroupAss 1.3.6.1.4.1.164.3.2.2.1.1.1.1.4
In case of T1 modules: group1=(1,2,3,4), ...., group6=(21,22,23,24) while in case of E1 modules: - If prtExPh1MlLineType=g732sE1 or g732sE1CRC: group1=(1,2,3,4),..,group4=(13,14,15,17), group5=(18,19,20,21),...,group7=(26,27,28,29) group8=(30,31). - If prtExPh1MlLineType=g732nE1 or g732nE1CRC: group1=(1,2,3,4),..,group4=(13,14,15,16), group5=(17,18,19,20),...,group7=(25,26,27,28) group8=(29,30,31).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER group1(1), group2(2), group3(3), group4(4), group5(5), group6(6), group7(7), group8(8), notApplicable(255)  

mdlPbxFraSignalMode 1.3.6.1.4.1.164.3.2.2.1.1.1.1.5
Refers to the signaling mode of the Framer module. tieTrunk(2), tieInvert(3), casTrans(4) are standard coding of the signaling protocol. casTrans(4) is Channel Associated Signaling (the signaling is within the channels time slot). ccsTrans(6) is Common Channel Signaling (the signaling is not within the channels time slot). userDefined(5) allows the user to define the signaling protocol he wants. In this case, the next two MIB fields are relevant.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), tieTrunk(2), tieInvert(3), casTrans(4), userDefined(5), ccsTrans(6)  

mdlPbxFraSignalVector 1.3.6.1.4.1.164.3.2.2.1.1.1.1.6
In the case of mdlPbxFraSignalMode = userDefined(5), this field defines the A,B,C Bits. D bit is supplied for future versions. Bit 1 = Bit A ON Hook - Local Bit 2 = Bit B ON Hook - Local Bit 3 = Bit C ON Hook - Local Bit 4 = Bit D ON Hook - Local Bit 5 = Bit A OFF Hook - Local Bit 6 = Bit B OFF Hook - Local Bit 7 = Bit C OFF Hook - Local Bit 8 = Bit D OFF Hook - Local Bit 9 = Bit A ON Hook - Remote Bit 10 = Bit B ON Hook - Remote Bit 11 = Bit C ON Hook - Remote Bit 12 = Bit D ON Hook - Remote Bit 13 = Bit A OFF Hook - Remote Bit 14 = Bit B OFF Hook - Remote Bit 15 = Bit C OFF Hook - Remote Bit 16 = Bit D OFF Hook - Remote In conjunction with the Mask, mdlPbxFraSignalMask, it is possible to compute the signal mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

mdlPbxFraSignalMask 1.3.6.1.4.1.164.3.2.2.1.1.1.1.7
In the case of mdlPbxFraSignalMode = userDefined(5), this field defines the 'don't care' A,B,C Bits. D bit is supplied for future versions. Bit 1 = Bit A ON Hook - Local Bit 2 = Bit B ON Hook - Local Bit 3 = Bit C ON Hook - Local Bit 4 = Bit D ON Hook - Local Bit 5 = Bit A OFF Hook - Local Bit 6 = Bit B OFF Hook - Local Bit 7 = Bit C OFF Hook - Local Bit 8 = Bit D OFF Hook - Local Bit 9 = Bit A ON Hook - Remote Bit 10 = Bit B ON Hook - Remote Bit 11 = Bit C ON Hook - Remote Bit 12 = Bit D ON Hook - Remote Bit 13 = Bit A OFF Hook - Remote Bit 14 = Bit B OFF Hook - Remote Bit 15 = Bit C OFF Hook - Remote Bit 16 = Bit D OFF Hook - Remote.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

mdlPbxFraFramerSlot 1.3.6.1.4.1.164.3.2.2.1.1.1.1.8
Slot where is sitting the Framer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

mdlPbxFraSignaling 1.3.6.1.4.1.164.3.2.2.1.1.1.1.9
Signaling - describes the way the signaling ABCD bits pass from the local extension to the remote extension and vice-versa. endToEnd = the signaling ABCD bits pass without change from local to remote extension. localTermination = the signaling ABCD bits received from the local extension are translated to different ON Hook/OFF Hook bit values and then passed to remote extension. This is relevant when the Local and Remote ON Hook/OFF Hook values are different.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), endToEnd(2), localTermination(3)  

prtExClCnfgTable 1.3.6.1.4.1.164.3.2.3.2.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExClCnfgEntry

prtExClCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.1.1.1
All the entries at this table are identical (have the same value) for all the configurations (1..100) except the TmpCnfg. The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtExClCnfgEntry  

prtExClCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.1.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtExClSltIdx 1.3.6.1.4.1.164.3.2.3.2.1.1.1.2
This attribute indicates a unique slot position where the card is inserted. Because the second Cl is only for redundancy, all the parameters are identical in the two modules, i.e. change of any parameter in one module will change automatically the value of the other module.. In the ?004 Unit the entry clB(4) is not valid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER clA(3), clB(4), notApplicable(255)  

prtExClPrtIdx 1.3.6.1.4.1.164.3.2.3.2.1.1.1.3
This attribute indicates a unique port number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2)  

prtExClUsage 1.3.6.1.4.1.164.3.2.3.2.1.1.1.4
This attribute indicates what is the usage of the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), noUse(2), nmsSlip(3), nmsPpp(4), muxSlip(5), muxPpp(6), terminal(7)  

prtExClRate 1.3.6.1.4.1.164.3.2.3.2.1.1.1.5
This attribute indicates the operation rate of the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER r300Bps(1), r1200Bps(2), r2400Bps(3), r4800Bps(4), r9600Bps(5), r19200Bps(6), r38400Bps(7), r57600Bps(8), r115200Bps(9)  

prtExClDataBits 1.3.6.1.4.1.164.3.2.3.2.1.1.1.6
This attribute indicates the number of data bits in async frame
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER dataBits7Bits(1), dataBits8Bits(2)  

prtExClParity 1.3.6.1.4.1.164.3.2.3.2.1.1.1.7
This attribute indicates if the parity operation mode in async frame
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER odd(1), even(2), none(3)  

prtExClStopBits 1.3.6.1.4.1.164.3.2.3.2.1.1.1.8
This attribute indicates the minimum number of stop bits in the tx async frame
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER stopBits1Bit(1), stopBits1dot5Bits(2), stopBits2Bits(3)  

prtExClRoutingProtocol 1.3.6.1.4.1.164.3.2.3.2.1.1.1.9
This attribute indicates the routing protocol of the port. When prtExClUsage is nmsSlip or nmsPpp - all values are applicable . Else - only 'none' is applicable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), rip2(2)  

prtExPh1MlCnfgTable 1.3.6.1.4.1.164.3.2.3.2.2.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExPh1MlCnfgEntry

prtExPh1MlCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.2.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtExPh1MlCnfgEntry  

prtExPh1MlCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.2.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtExPh1MlSltIdx 1.3.6.1.4.1.164.3.2.3.2.2.1.1.2
This attribute indicates a unique slot position where the module is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExPh1MlPrtIdx 1.3.6.1.4.1.164.3.2.3.2.2.1.1.3
This attribute indicates a unique port number. MTML-1/E1 and MTML-1/T1 cards have only one external interface. inPrt1 - for MTML-H/E1 cards. exPrt2..exPrt4 - for MTML-4 cards and others.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), inPrt1(101)  

prtExPh1MlConnect 1.3.6.1.4.1.164.3.2.3.2.2.1.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms. It also affects all the card considerations because it may indicate that the module has only one physical interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExPh1MlLineType 1.3.6.1.4.1.164.3.2.3.2.2.1.1.5
This attribute is the line type parameter for T1/E1 interface. The user should select only the parameters which are relevant to the specific card: T1 line code parameters for the MPH.1/T1 E1 line code parameters for the MPH.1/E1. This parameter has the same values as dsx1LineType in T1/E1 MIB (RFC-1406). The parameters in dsx1LineType are: other (1) esfT1 dsx1ESF (2) sfT1 dsx1D4 (3) g732nE1 dsx1E1 (4) g732nE1CRC dsx1E1-CRC (5) g732sE1 dsx1E1-MF (6) g732sE1CRC dsx1E1-MF-CRC (7)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER esfT1(2), sfT1(3), g732nE1(4), g732nE1CRC(5), g732sE1(6), g732sE1CRC(7)  

prtExPh1MlLineCode 1.3.6.1.4.1.164.3.2.3.2.2.1.1.6
This attribute is the line code parameter used for T1/E1 interface. The user should select only the parameters which are relevant to the specific card: T1 line code parameters for MPH.1/T1 E1 line code parameters for MPH.1/E1. This parameter has the same values as dsx1LineCoding in T1/E1 MIB (RFC-1406). The parameters in dsx1LineCoding are: dsx1JBZS (1) dsx1B8ZS (2) dsx1HDB3 (3) dsx1ZBTSI (4) dsx1AMI (5) other (6)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER b7T1(1), b8zsT1(2), transT1(3), hdb3E1(4), notApplicable(255)  

prtExPh1MlLineLen 1.3.6.1.4.1.164.3.2.3.2.2.1.1.7
This attribute is the line length parameter used only for T1/DSU interfaces. lenXXXpXXXft = len-XXX-XXXft.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), len0p133ft(2), len134p266ft(3), len267p399ft(4), len400p533ft(5), len534p655ft(6), lenFcc68(7), notApplicable(255)  

prtExPh1MlRestoreTime 1.3.6.1.4.1.164.3.2.3.2.2.1.1.8
The time passing from the disappearance of the loss of synchronization condition (red alarm) to the restoration of normal service. The options 1secFast(2) and 10sec62411(3) for E1 interfaces are proprietary implementation of the T1 standard to the E1 interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER restoreT1secFast(2), restoreT10sec62411(3), ccittE1(4)  

prtExPh1MlTxGain 1.3.6.1.4.1.164.3.2.3.2.2.1.1.9
This attribute is the tx gain parameter used only for T1/CSU interfaces.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), txGain0db(2), txGain7dot5db(3), txGain15db(4), txGain22dot5db(5)  

prtExPh1MlRxSensitivity 1.3.6.1.4.1.164.3.2.3.2.2.1.1.10
This attribute is the rx line sensitivity parameter. low26dBm, high36dBm - applicable for T1-CSU shortHaul, longHaul - applicable for MTML-4 cards.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), low26dBm(2), high36dBm(3), shortHaul(4), longHaul(5)  

prtExPh1MlIdleCode 1.3.6.1.4.1.164.3.2.3.2.2.1.1.11
Determines the code for transmission in empty time slots. Type value(00-FFH), Excluding 0H,8H,10H,12H,21H,24H,42H,49H, 84H,92H
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

prtExPh1MlTdmTrunk 1.3.6.1.4.1.164.3.2.3.2.2.1.1.12
This attribute indicates whether the port is used to transfer TDM cards data and through which Bus.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER linkA(1), linkB(2), none(3), notApplicable(255)  

prtExPh1MlClkMode 1.3.6.1.4.1.164.3.2.3.2.2.1.1.13
Defines the clock operation mode of the T1/E1 interface. Ports that are connected to the TDM Buses must be in nodalTiming(3) clock mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER internalLocal(1), loopBackLocal(2), nodalTiming(3)  

prtExPh1MlMfClkSrcSlt 1.3.6.1.4.1.164.3.2.3.2.2.1.1.14
This attribute indicates whether the port Tx multiframe is synchronized with Rx multiframe of another port and the slot position of that port. This operation is required in order to bypass signaling of PCM voice channels. Its value is always local(2) when the port isn't connected to any TDM bus. When it's value is local(2) there is no meaning to 'prtExPh1MlMfClkSrcPrt' parameter. In the ?004 Unit the entries io6(10)..io16) are not valid
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), local(2), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExPh1MlMfClkSrcPrt 1.3.6.1.4.1.164.3.2.3.2.2.1.1.15
A unique number to identify a port position in the mux. It has no effect when the prtExPh1MlMfClkSrcSlt selected is Local. inPrt1 - for MTML-H/E1 cards.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), inPrt1(101), notApplicable(255)  

prtExPh1MlFdlType 1.3.6.1.4.1.164.3.2.3.2.2.1.1.16
A unique number to identify the side of the FDL operation. Normal: 'response' for the user side and 'command' for the PTT side. Applicable only when working with ESF-T1 link
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), response(2), command(3)  

prtExPh1MlInbandMng 1.3.6.1.4.1.164.3.2.3.2.2.1.1.17
A unique number to identify an Inband management over the link.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(2), fdlOrTs0(3), dedicatedTs(4), dedicatedPpp(5), dedicatedFr(6), notApplicable(255)  

prtExPh1MlInbandMngRate 1.3.6.1.4.1.164.3.2.3.2.2.1.1.18
A unique number to identify the rate of the Inband management. E1 port - it is not applicable when prtExPh1MlInbandMng selected is off. T1 port - it is not applicable when prtExPh1MlInbandMng selected is off OR fdlOrTs0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), r4k(2), r8k(3), r12k(4), r16k(5), r32k(6), r64k(7), r20k(8)  

prtExPh1MlRedundType 1.3.6.1.4.1.164.3.2.3.2.2.1.1.19
This object determines the ML redundancy type: none - no ML redundacy dualCableAIS - each ML card is connected by a separate dualCableParallelTx cable to the other MUX (two cables connect two MUXes). There are two types of dual redundancy. yCable - Y cable is connected to both ML cards (one cable connects two MUXes). Default=none When only one ML card exists, the type can be only 'none'. The value should be the same for both ML slots.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), dualCableAIS(2), yCable(3), dualCableParallelTx(4)  

prtExPh1MlRedundSlot 1.3.6.1.4.1.164.3.2.3.2.2.1.1.20
This object indicates the slot containing the redundacy ML card, coupled with the current ML (prtExPh1MlSltIdx). When prtExPh1MlRedundType=none (no ML redundancy) this object will be 'notApplicable'. In the ?004 Unit the entries io6(10)..io12(16) are not valid When value is not 'none', it should be mutual to the redundant ML slot.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExPh1MlRedundPort 1.3.6.1.4.1.164.3.2.3.2.2.1.1.21
This object indicates the redundacy ML port, coupled with the current ML port (prtExPh1MlPrtIdx). When prtExPh1MlRedundType=none (no ML redundancy) this object will be 'notApplicable'. When value is not 'none', it should be mutual to the redundant ML port. inPrt1 - for MTML-H/E1 cards. exPrt2..exPrt4 - for MTML-4 cards.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), inPrt1(101), notApplicable(255)  

prtExPh1MlRedundRecTime 1.3.6.1.4.1.164.3.2.3.2.2.1.1.22
Redundancy Recovery Time (sec). After switching the ML card to the current (prtExPh1MlSltIdx), the next ML switch can be performed only after a minimum time, indicated by this object.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..99  

prtExPh1MlInbandMngRoutProt 1.3.6.1.4.1.164.3.2.3.2.2.1.1.23
This attribute indicates the Inband Mng routing protocol of the port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), rip2(2), proprietary(3)  

prtExPh1MlIfType 1.3.6.1.4.1.164.3.2.3.2.2.1.1.24
Interface type of the port. For T1 - csu, dsu are the valid values For E1 - dsu, ltu are the valid values.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), csu(2), dsu(3), ltu(4)  

prtExPh1MlTsTable 1.3.6.1.4.1.164.3.2.3.2.2.2
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExPh1MlTsEntry

prtExPh1MlTsEntry 1.3.6.1.4.1.164.3.2.3.2.2.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtExPh1MlTsEntry  

prtExPh1MlTsCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.2.2.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtExPh1MlTsSltIdx 1.3.6.1.4.1.164.3.2.3.2.2.2.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExPh1MlTsPrtIdx 1.3.6.1.4.1.164.3.2.3.2.2.2.1.3
This attribute indicates a unique port number. MPH.1/E1 and MPH.1/T1 cards have only one external interface. exPrt2 - for ME1-2, MT1-2 and mhsPri cards. exPrt3, exPrt4 - for mhsPri cards. inPrt1 - for MTML-H/E1 cards.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), inPrt1(101)  

prtExPh1MlTsIdx 1.3.6.1.4.1.164.3.2.3.2.2.2.1.4
This attribute indicates a unique time slot position. The valid time slots are 1..24 for T1 Card and 1..31 for E1 interface. In G732S-E1 lines time slot 16 is not valid for data, it is dedicated for multiframe synchronization bits and voice signaling.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtExPh1MlTsIConSlot 1.3.6.1.4.1.164.3.2.3.2.2.2.1.5
This attribute indicates whether the specified time slot is connected/routed internally in the Agent and to which card it is connected. In the ?004 Unit the entries io6(10)..io16) are not valid. split - will be used when the Src TS is connected to more than one slot OR more than one port (each needing less than a whole TS).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noConnect(2), split(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExPh1MlTsIConPrt 1.3.6.1.4.1.164.3.2.3.2.2.2.1.6
This attribute indicates the internally (In Mux) connected/routed port. For MP, the values will be: { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) , exPrt7 (7) , exPrt8 (8) , exPrt9 (9) , exPrt10 (10) , exPrt11 (11) , exPrt12 (12) , noConnect (100), inPrt1 (101) , inPrt2 (102) , inPrt3 (103) , inPrt4 (104) , inPrt5 (105) , inPrt6 (106) , inPrt7 (107) , inPrt8 (108) , inPrt9 (109) , inPrt10 (110) , inPrt11 (111) , inPrt12 (112) }
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

prtExPh1MlTsIConTs 1.3.6.1.4.1.164.3.2.3.2.2.2.1.7
This attribute indicates a unique time slot position. The valid time slots are 1..24 for T1 Card and 1..31 for E1 interface. In G732S-E1 lines time slot 16 is not valid for data, it is dedicated to multiframe synchronization and voice signaling.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

prtExPh1MlTsExt 1.3.6.1.4.1.164.3.2.3.2.2.2.1.8
A pointer to an extension of this table: prtExTsSplitTable. - If prtExPh1MlTsIConSlot='split', its value should be set to the OBJECT IDENTIFIER of the prtExTsSplitTable, with its relevant CnfgIdx, SltIdx, PrtIdx, TsIdx and 1st TsBit. - If prtExPh1MlTsIConSlot is not 'split', its value should be set to the OBJECT IDENTIFIER { 0 0 }.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

prtInPh1MlCnfgTable 1.3.6.1.4.1.164.3.2.3.2.2.3
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtInPh1MlCnfgEntry

prtInPh1MlCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.2.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtInPh1MlCnfgEntry  

prtInPh1MlCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.2.3.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtInPh1MlSltType 1.3.6.1.4.1.164.3.2.3.2.2.3.1.2
This attribute indicates a unique slot position where the card is inserted. For ISDN BRI port of MX300/30: io1(5) = isdn1(5) and io2(6) = isdn2(6) In the ?004 Unit the entries io6(10)..io12(16) are not valid
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtInPh1MlPrtIdx 1.3.6.1.4.1.164.3.2.3.2.2.3.1.3
This attribute indicates a unique port number. MPH.1/E1 and MPH.1/T1 cards have three internal interfaces. MX3000 modules may have up to 50 internal ports.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtInPh1MlConnect 1.3.6.1.4.1.164.3.2.3.2.2.3.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtInPh1MlRate 1.3.6.1.4.1.164.3.2.3.2.2.3.1.5
This attribute indicates the port speed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER r1x56eq56Kbps(1), r1x64eq64Kbps(2), r2x56eq112Kbps(3), r2x64eq128Kbps(4), r3x56eq168Kbps(5), r3x64eq192Kbps(6), r4x56eq224Kbps(7), r4x64eq256Kbps(8), r5x56eq280Kbps(9), r5x64eq320Kbps(10), r6x56eq336Kbps(11), r6x64eq384Kbps(12), r7x56eq392Kbps(13), r7x64eq448Kbps(14), r8x56eq448Kbps(15), r8x64eq512Kbps(16), r9x56eq504Kbps(17), r9x64eq576Kbps(18), r10x56eq560Kbps(19), r10x64eq640Kbps(20), r11x56eq616Kbps(21), r11x64eq704Kbps(22), r12x56eq672Kbps(23), r12x64eq768Kbps(24), r13x56eq728Kbps(25), r13x64eq832Kbps(26), r14x56eq784Kbps(27), r14x64eq896Kbps(28), r15x56eq840Kbps(29), r15x64eq960Kbps(30), r16x56eq896Kbps(31), r16x64eq1024Kbps(32), r17x56eq952Kbps(33), r17x64eq1088Kbps(34), r18x56eq1008Kbps(35), r18x64eq1152Kbps(36), r19x56eq1064Kbps(37), r19x64eq1216Kbps(38), r20x56eq1120Kbps(39), r20x64eq1280Kbps(40), r21x56eq1176Kbps(41), r21x64eq1344Kbps(42), r22x56eq1232Kbps(43), r22x64eq1408Kbps(44), r23x56eq1288Kbps(45), r23x64eq1472Kbps(46), r24x56eq1344Kbps(47), r24x64eq1536Kbps(48), r25x56eq1400Kbps(49), r25x64eq1600Kbps(50), r26x56eq1456Kbps(51), r26x64eq1664Kbps(52), r27x56eq1512Kbps(53), r27x64eq1728Kbps(54), r28x56eq1568Kbps(55), r28x64eq1792Kbps(56), r29x56eq1624Kbps(57), r29x64eq1856Kbps(58), r30x56eq1680Kbps(59), r30x64eq1920Kbps(60), r31x56eq1736Kbps(61), r31x64eq1984Kbps(62), noRate(100)  

prtInPh1MlProtocol 1.3.6.1.4.1.164.3.2.3.2.2.3.1.6
This attribute indicates the applied protocol.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER fr(1), frPlus(2), pCellRelay(3), hdlcSdlc(4), transparentHdlc(5)  

prtInPh1MlConnectionTyp 1.3.6.1.4.1.164.3.2.3.2.2.3.1.7
This attribute indicates the link connection type. It is required for three reasons: FR/CR Inband management operation (LMI,CLMM...). CIR check. NMS network management. SameNetManaged - indicates network internal line. SameNetNotMana - indicates network internal line, but the remote mux is not managed by the nms. User - User to Network Interface. OtherNet - Network To Network Interfce. PubNet - Access Mux To PubNet Interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER sameNetManaged(1), sameNetNotMana(2), user(3), otherNet(4), pubNet(5), notApplicable(255)  

prtInPh1MlCongResponse 1.3.6.1.4.1.164.3.2.3.2.2.3.1.8
This attribute indicates how to handle the congestion indication to/from the mux internal connection side (for example transmit/receive becn to/from the network). no - do nothing FlowControl - translate the congestion indication between the port and the internal connection port according to the definition of the prtInPh1MlFlowControl parameters. The operation is done in both directions.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), flowControl(3)  

prtInPh1MlCongLevel 1.3.6.1.4.1.164.3.2.3.2.2.3.1.9
This attribute indicates the level of delayed data in precents of the total available dynamic memory, for which the port will start to operate . The resolution of the parameter is 5 percent. Valid values: 10..70, 255. 255=notApplicable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

prtInPh1MlTc 1.3.6.1.4.1.164.3.2.3.2.2.3.1.10
This attribute indicates the Tc parameter which is the time period of the sliding window in which the Bc/Be are tested. The value of this parameter is identical for all the ports in the specific card. 255=notApplicable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER tc1sec(1), tc2sec(2), tc3sec(3), tc4sec(4), notApplicable(255)  

prtInPh1MlFlowControl 1.3.6.1.4.1.164.3.2.3.2.2.3.1.11
This attribute indicates the required flow control betweeen the port and the remote equipment.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(2), fecnBecn(3)  

prtInPh1MlSegment 1.3.6.1.4.1.164.3.2.3.2.2.3.1.12
This object is the Segmentation in Bytes. In protocol FR+, ISDN internals, MX 30/300 the segmentation is: 50 (2) ,158 (3) ,266 (4) ,376 (5), 484 (6) In MX 3000/4: For protocol FR+ (internal ISDN ports of MHS.S, MHS.U, MHS.E1, MHS.T1 cards) segmentation values are: 236 (7),472 (8), 708 (9), 944 (10) ,1180 (11)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), s36Byte(2), s150Byte(3), s264Byte(4), s378Byte(5), s492Byte(6), s236Byte(7), s472Byte(8), s708Byte(9), s944Byte(10), s1180Byte(11)  

prtInPh1MlFrMngProt 1.3.6.1.4.1.164.3.2.3.2.2.3.1.13
This object indicates the Frame-Relay management protocol. ansiT1 = ANSI T1.617 Annex D (this is the default value). This parameter is applicable only for FR and FR+ protocols. When prtInPh1MlConnectionTyp = sameNetManaged, this object will be RO (internally determined).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), lmi(3), ansiT1(4), annexA(5)  

prtInPh1MlEnqPeriod 1.3.6.1.4.1.164.3.2.3.2.2.3.1.14
This object is the Status Enquiry Period, in seconds. It determines the frequency of the Status Enquiry message as sent by the FR user side. At the FR network side, it determines the timeout for this message reception. Default = 4 seconds. This parameter is applicable only for FR and FR+ protocols AND only when prtInPh1MlFrMngProt is NOT (notApplicable or none). 0=notApplicable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..30  

prtInPh1MlFullRptPeriod 1.3.6.1.4.1.164.3.2.3.2.2.3.1.15
This object is the Full Report Frequency. It determines the number of the Status Enquiry messages sent by the FR user side, before a Full Report Request is sent. The units are : Status Enquiry messages (periods). Valid values: 1 .. 255. 255 = infinite (never sent). This parameter is applicable only for FR and FR+ protocols AND only when prtInPh1MlFrMngProt is NOT (notApplicable or none). 0=notApplicable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

prtInPh1MlFrWindowSize 1.3.6.1.4.1.164.3.2.3.2.2.3.1.16
This object is the FR Window Size. It determines the number of samplings in the sliding window that counts the errors. This parameter is applicable only for FR and FR+ protocols AND only when prtInPh1MlFrMngProt is NOT (notApplicable or none). 0=notApplicable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..10  

prtInPh1MlErrorsThreshold 1.3.6.1.4.1.164.3.2.3.2.2.3.1.17
This object is the Max Errors. It determines the number of Status Enquiry Errors that occured within the FR sliding window, before this port is considered DOWN (threshold). This parameter is applicable only for FR and FR+ protocols AND only when prtInPh1MlFrMngProt is NOT (notApplicable or none). 0=notApplicable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..10  

prtInPh1MlMaxIdleTime 1.3.6.1.4.1.164.3.2.3.2.2.3.1.18
Move to higher prioritized connected link after this period of seconds of silence on the current link. 0=Never. Never move to higher prioritized connected link. UNIT is seconds. Valid values are: 0, 1, 2, 3, 4, 5, 10, 20, 30, 40, 50, 60, 120, 180, 240, 300, 360, 420, 480, 540, 600, 900, 1200, 1500, 1800. Attempt to Set an invalid value will result in getting the default value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1800  

prtInPh1MlBearerCh 1.3.6.1.4.1.164.3.2.3.2.2.3.1.19
Defines which B (bearer) channels are used for transferring ISDN data. Default value is: none (255). anyChannel (2) is skipped because it is not in use here.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), channelB1(3), channelB2(4), chB1andchB2(5), none(255)  

prtInPh1MlAssociatedExCh 1.3.6.1.4.1.164.3.2.3.2.2.3.1.20
This object indicates the external port associated to this internal port. At present, it is used by the Hybrid (mp2100h), MHS-4 cards which can have up to 64 dynamic internal ports associated with External ports. For ISDN cards, the value will be: notApplicable (255). The associated external of an ISDN internal port is represented by the MIB object: prtIsdnDirectoryPrtNu.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), notApplicable(255)  

prtInPh1MlClockEncoding 1.3.6.1.4.1.164.3.2.3.2.2.3.1.21
This object is the Encoding type of the Line. This parameter is applicable only for FR and FR+ protocols.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), nrz(2), nrzI(3), fm0(4), manchester(5), diffManchester(6)  

prtInPh1MlMinSeparators 1.3.6.1.4.1.164.3.2.3.2.2.3.1.22
Minimum number of bytes separating between two adjacent frames (HDLC item). 0 = notApplicable
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..16  

prtInPh1MlCcittCrc 1.3.6.1.4.1.164.3.2.3.2.2.3.1.23
This object indicates how many Bits are used for CRC (HDLC item).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), crc16(2), crc32(3)  

prtInPh1MlFrameSeparator 1.3.6.1.4.1.164.3.2.3.2.2.3.1.24
This object indicates what should be transferred on the line when there are no frames to pass (HDLC item). idles: mean that FF will pass on the line flags: mean that 7E will pass on the line.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), idles(2), flags(3)  

prtInPh1MlDlciTable 1.3.6.1.4.1.164.3.2.3.2.2.4
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtInPh1MlDlciEntry

prtInPh1MlDlciEntry 1.3.6.1.4.1.164.3.2.3.2.2.4.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtInPh1MlDlciEntry  

prtInPh1MlDlciCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.2.4.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtInPh1MlDlciSltIdx 1.3.6.1.4.1.164.3.2.3.2.2.4.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtInPh1MlDlciPrtIdx 1.3.6.1.4.1.164.3.2.3.2.2.4.1.3
This attribute indicates a unique internal port number. MPH.1/E1 and MPH.1/T1 cards have three internal ports.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER inPrt1(101), inPrt2(102), inPrt3(103)  

prtInPh1MlDlciIdx 1.3.6.1.4.1.164.3.2.3.2.2.4.1.4
This attribute indicates a unique index for each possible used dlci(16..991). When the protocol is not Multiplexing protocol, then its type is 'user' and the only valid index is 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..991  

prtInPh1MlDlciValid 1.3.6.1.4.1.164.3.2.3.2.2.4.1.5
This attribute indicates whether the attributes in this entry are valid or not. The user can add/delete pvc (dlci to dlci connection) by modifing this object
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtInPh1MlDlciIConSlt 1.3.6.1.4.1.164.3.2.3.2.2.4.1.6
This attribute indicates a unique slot position In the Mux (Agent) where the dlci is routed to. In the ?004 Unit the entries io6(10)..io16) are not valid
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noConnect(2), cl(3), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtInPh1MlDlciIConPrt 1.3.6.1.4.1.164.3.2.3.2.2.4.1.7
This attribute indicates a unique port id which the dlci is routed to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), exPrt9(9), exPrt10(10), clNMS(99), noConnect(100), inPrt1(101), inPrt2(102), inPrt3(103), inPrt4(104), inPrt5(105), inPrt6(106), inPrt7(107), inPrt8(108), inPrt9(109), inPrt10(110), inPrt11(111), inPrt12(112)  

prtInPh1MlDlciIConDlci 1.3.6.1.4.1.164.3.2.3.2.2.4.1.8
This attribute indicates a unique internal connection dlci number which the src dlci is routed to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..991  

prtInPh1MlDlciTxBc 1.3.6.1.4.1.164.3.2.3.2.2.4.1.9
This attribute indicates a unique Tx committed bandwidth on the user transmit line or at the port receive line.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER full(1), zero(2), txBc9600bps(3), txBc14200bps(4), txBc19200bps(5), txBc28800bps(6), txBc32000bps(7), txBc38400bps(8), txBc48000bps(9), txBc56000bps(10), txBc57600bps(11), txBc64Kbps(12), txBc128Kbps(13), txBc192Kbps(14), txBc256Kbps(15), txBc320Kbps(16), txBc384Kbps(17), txBc448Kbps(18), txBc512Kbps(19), txBc768Kbps(20), txBc1024Kbps(21)  

prtInPh1MlDlciTxBe 1.3.6.1.4.1.164.3.2.3.2.2.4.1.10
This attribute indicates a unique Tx excess bandwidth on the user transmit line or at the port receive line.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER full(1), zero(2), txBe9600bps(3), txBe14200bps(4), txBe19200bps(5), txBe28800bps(6), txBe32000bps(7), txBe38400bps(8), txBe48000bps(9), txBe56000bps(10), txBe57600bps(11), txBe64Kbps(12), txBe128Kbps(13), txBe192Kbps(14), txBe256Kbps(15), txBe320Kbps(16), txBe384Kbps(17), txBe448Kbps(18), txBe512Kbps(19), txBe768Kbps(20), txBe1024Kbps(21)  

prtInPh1MlDlciRxBc 1.3.6.1.4.1.164.3.2.3.2.2.4.1.11
This attribute indicates a unique Rx committed bandwidth on the user receive line or at the port transmit line.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER full(1), zero(2), rxBc9600bps(3), rxBc14200bps(4), rxBc19200bps(5), rxBc28800bps(6), rxBc32000bps(7), rxBc38400bps(8), rxBc48000bps(9), rxBc56000bps(10), rxBc57600bps(11), rxBc64Kbps(12), rxBc128Kbps(13), rxBc192Kbps(14), rxBc256Kbps(15), rxBc320Kbps(16), rxBc384Kbps(17), rxBc448Kbps(18), rxBc512Kbps(19), rxBc768Kbps(20), rxBc1024Kbps(21)  

prtInPh1MlDlciRxBe 1.3.6.1.4.1.164.3.2.3.2.2.4.1.12
This attribute indicates a unique Rx excess bandwidth on the user receive line or at the port transmit line.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER full(1), zero(2), rxBe9600bps(3), rxBe14200bps(4), rxBe19200bps(5), rxBe28800bps(6), rxBe32000bps(7), rxBe38400bps(8), rxBe48000bps(9), rxBe56000bps(10), rxBe57600bps(11), rxBe64Kbps(12), rxBe128Kbps(13), rxBe192Kbps(14), rxBe256Kbps(15), rxBe320Kbps(16), rxBe384Kbps(17), rxBe448Kbps(18), rxBe512Kbps(19), rxBe768Kbps(20), rxBe1024Kbps(21)  

prtInPh1MlDlciPriority 1.3.6.1.4.1.164.3.2.3.2.2.4.1.13
This attribute indicates a unique priority of the pcv. 1 is the lowest priority and 8 is the highest priority.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..8  

prtInPh1MlDlciStatus 1.3.6.1.4.1.164.3.2.3.2.2.4.1.14
This attribute indicates the status of the pvc. The status is disconnected(1) when one of the sides is programmed as not connected
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disconnected(1), connected(2)  

prtPhMlCnfgTable 1.3.6.1.4.1.164.3.2.3.2.2.5
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtPhMlCnfgEntry

prtPhMlCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.2.5.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtPhMlCnfgEntry  

prtPhMlCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.2.5.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtPhMlSltIdx 1.3.6.1.4.1.164.3.2.3.2.2.5.1.2
This attribute indicates a unique slot position where the module is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtPhMlPrtIdx 1.3.6.1.4.1.164.3.2.3.2.2.5.1.3
This attribute indicates a unique port number. ML-20 cards have just one external interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1)  

prtPhMlConnect 1.3.6.1.4.1.164.3.2.3.2.2.5.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtPhMlRate 1.3.6.1.4.1.164.3.2.3.2.2.5.1.5
This attribute indicates the port speed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER r2x64eq128Kbps(4), r3x64eq192Kbps(6), r4x64eq256Kbps(8), r5x64eq320Kbps(10), r6x64eq384Kbps(12), r7x64eq448Kbps(14), r8x64eq512Kbps(16), r9x64eq576Kbps(18), r10x64eq640Kbps(20), r11x64eq704Kbps(22), r12x64eq768Kbps(24), r13x64eq832Kbps(26), r14x64eq896Kbps(28), r15x64eq960Kbps(30), r16x64eq1024Kbps(32), r17x64eq1088Kbps(34), r18x64eq1152Kbps(36), r19x64eq1216Kbps(38), r20x64eq1280Kbps(40), r21x64eq1344Kbps(42), r22x64eq1408Kbps(44), r23x64eq1472Kbps(46), r24x64eq1536Kbps(48), r25x64eq1600Kbps(50), r26x64eq1664Kbps(52), r27x64eq1728Kbps(54), r28x64eq1792Kbps(56), r29x64eq1856Kbps(58), r30x64eq1920Kbps(60), r31x64eq1984Kbps(62)  

prtPhMlCAS 1.3.6.1.4.1.164.3.2.3.2.2.5.1.6
This attribute indicates whether Channel Associated Signaling (CAS) is used.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtPhMlClockMode 1.3.6.1.4.1.164.3.2.3.2.2.5.1.7
Clock mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dce(2), ext-dce(3), dte(4)  

prtPhMlSatBuffer 1.3.6.1.4.1.164.3.2.3.2.2.5.1.8
Satellite Buffer (+/- 256).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtPhMlDialProcess 1.3.6.1.4.1.164.3.2.3.2.2.5.1.9
Dial Process.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), callIn(3), callOut(4)  

prtPhMlSyncRestore 1.3.6.1.4.1.164.3.2.3.2.2.5.1.10
Sync Restoration time, in seconds. notApplicable=0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..10  

prtPhMlBus 1.3.6.1.4.1.164.3.2.3.2.2.5.1.11
The TDM BUS this port is linked to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), busA(2), busB(3)  

prtPhMlMfSyncSlot 1.3.6.1.4.1.164.3.2.3.2.2.5.1.12
This attribute indicates whether the sync is synchronized according to a certain card and the slot of this card. This operation is required in order to bypass signaling of PCM voice channels. In the ?004 Unit the entries io6(10)..io12(16) are not valid
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(2), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtLogicalCnfgTable 1.3.6.1.4.1.164.3.2.3.2.17.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtLogicalCnfgEntry

prtLogicalCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.17.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtLogicalCnfgEntry  

prtLogicalCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.17.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtLogicalSltIdx 1.3.6.1.4.1.164.3.2.3.2.17.1.1.2
Slot Index. For ISDN BRI Ports of MX300/30, io1(5) = isdn1(5) and io2(6) = isdn2(6).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtLogicalPrtIdx 1.3.6.1.4.1.164.3.2.3.2.17.1.1.3
This attribute indicates a unique port number. This port number should be an internal port number: inPrt1(101)->inPrt50(150), linkSel1(200)->linkSel50(250), encaps1(300)-> encaps50(350), huntGr1(101) -> huntGr10(110).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtLogicalConnect 1.3.6.1.4.1.164.3.2.3.2.17.1.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtLogicalFunction 1.3.6.1.4.1.164.3.2.3.2.17.1.1.5
This parameter defines the function of the relevant channel.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), linkSelector(2), encapsulator(3), huntGroup(4)  

prtLogicalRowStatus 1.3.6.1.4.1.164.3.2.3.2.17.1.1.6
This parameter allows the NMS to create/delete logical ports.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER active(1), destroy(6)  

linkSelectorCnfgTable 1.3.6.1.4.1.164.3.2.3.2.17.2
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LinkSelectorCnfgEntry

linkSelectorCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.17.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  LinkSelectorCnfgEntry  

linkSelectorCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.17.2.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

linkSelectorSltIdx 1.3.6.1.4.1.164.3.2.3.2.17.2.1.2
Slot Index
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

linkSelectorPrtIdx 1.3.6.1.4.1.164.3.2.3.2.17.2.1.3
This attribute indicates a unique port number. This port number should be internal port number: higher or equal to linkSeL1(201).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

linkSelectorMaxIdleTime 1.3.6.1.4.1.164.3.2.3.2.17.2.1.4
Move to higher prioritized connected link after this period of seconds of silence on the current link. 0=move immediately to higher prioritized connected link. UNIT is seconds.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

linkSelectorMode 1.3.6.1.4.1.164.3.2.3.2.17.2.1.5
If the link selector is in mode: backup(2)=then the link with the lower priority will be used in case of failure of the higher priority link, bod(3)=bandwidth on demand or dynamic bandwidth allocation means that links with lower priority will be used whenever additional bandwidth is required.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), backup(2), bod(3)  

linkSelectorRevert 1.3.6.1.4.1.164.3.2.3.2.17.2.1.6
If the link selector is in mode backup: auto(2)=return automatically to Main link when it is OK. manual(3)=stays connected to backup link.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), auto(2), manual(3)  

linkSelectorMinBUSession 1.3.6.1.4.1.164.3.2.3.2.17.2.1.7
Minimum duration of a backup session before returning to Main Link. Relevant in Backup Mode and when Revert is auto(2). Value 255 is for NEVER which means never return to Main Link. UNIT is minutes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

linkSelectorPLinkTable 1.3.6.1.4.1.164.3.2.3.2.17.3
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LinkSelectorPLinkEntry

linkSelectorPLinkEntry 1.3.6.1.4.1.164.3.2.3.2.17.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  LinkSelectorPLinkEntry  

pLinkCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.17.3.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

pLinkSltIdx 1.3.6.1.4.1.164.3.2.3.2.17.3.1.2
Slot Index
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

pLinkPrtIdx 1.3.6.1.4.1.164.3.2.3.2.17.3.1.3
This attribute indicates a unique port number. This port number should be the link selector number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 200..250  

pLinkIdx 1.3.6.1.4.1.164.3.2.3.2.17.3.1.4
This index is the row number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..8  

pLinkSlotNu 1.3.6.1.4.1.164.3.2.3.2.17.3.1.5
The slot of the prioritized link. For ISDN BRI ports of MX300/30, io1(5) = isdn1(5) and io2(6) = isdn2(6).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noConnect(2), cl(3), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

pLinkPortNu 1.3.6.1.4.1.164.3.2.3.2.17.3.1.6
The port of the prioritized link. Value 100 is for noConnect.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

pLinkPrioNu 1.3.6.1.4.1.164.3.2.3.2.17.3.1.7
The priority of the prioritized link. MIN=1...., MAX=8.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..8  

pLinkVRate 1.3.6.1.4.1.164.3.2.3.2.17.3.1.8
The rate to use with this link.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER r1x56eq56Kbps(1), r1x64eq64Kbps(2), r2x56eq112Kbps(3), r2x64eq128Kbps(4), r3x56eq168Kbps(5), r3x64eq192Kbps(6), r4x56eq224Kbps(7), r4x64eq256Kbps(8), r5x56eq280Kbps(9), r5x64eq320Kbps(10), r6x56eq336Kbps(11), r6x64eq384Kbps(12), r7x56eq392Kbps(13), r7x64eq448Kbps(14), r8x56eq448Kbps(15), r8x64eq512Kbps(16), r9x56eq504Kbps(17), r9x64eq576Kbps(18), r10x56eq560Kbps(19), r10x64eq640Kbps(20), r11x56eq616Kbps(21), r11x64eq704Kbps(22), r12x56eq672Kbps(23), r12x64eq768Kbps(24), r13x56eq728Kbps(25), r13x64eq832Kbps(26), r14x56eq784Kbps(27), r14x64eq896Kbps(28), r15x56eq840Kbps(29), r15x64eq960Kbps(30), r16x56eq896Kbps(31), r16x64eq1024Kbps(32), r17x56eq952Kbps(33), r17x64eq1088Kbps(34), r18x56eq1008Kbps(35), r18x64eq1152Kbps(36), r19x56eq1064Kbps(37), r19x64eq1216Kbps(38), r20x56eq1120Kbps(39), r20x64eq1280Kbps(40), r21x56eq1176Kbps(41), r21x64eq1344Kbps(42), r22x56eq1232Kbps(43), r22x64eq1408Kbps(44), r23x56eq1288Kbps(45), r23x64eq1472Kbps(46), r24x56eq1344Kbps(47), r24x64eq1536Kbps(48), r25x56eq1400Kbps(49), r25x64eq1600Kbps(50), r26x56eq1456Kbps(51), r26x64eq1664Kbps(52), r27x56eq1512Kbps(53), r27x64eq1728Kbps(54), r28x56eq1568Kbps(55), r28x64eq1792Kbps(56), r29x56eq1624Kbps(57), r29x64eq1856Kbps(58), r30x56eq1680Kbps(59), r30x64eq1920Kbps(60), r31x56eq1736Kbps(61), r31x64eq1984Kbps(62), noRate(100)  

prtExPhPlCnfgTable 1.3.6.1.4.1.164.3.2.3.2.3.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExPhPlCnfgEntry

prtExPhPlCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.3.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtExPhPlCnfgEntry  

prtExPhPlCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.3.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtExPhPlSltIdx 1.3.6.1.4.1.164.3.2.3.2.3.1.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExPhPlPrtIdx 1.3.6.1.4.1.164.3.2.3.2.3.1.1.3
This attribute indicates a unique port number. In case of PH.1 card, only exPrt(1) is valid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6)  

prtExPhPlConnect 1.3.6.1.4.1.164.3.2.3.2.3.1.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExPhPlHRate 1.3.6.1.4.1.164.3.2.3.2.3.1.1.5
This attribute indicates the port speed for HIGH speed cards. The card has limitations about the maximum sigma channel speeds and about the possible rates for each clock mode . N - The rate is valid for DCE and EXT-DCE Nodal clock mode. L - The rate is valid for DCE and EXT-DCE Local clock mode. E - The rate is valid for DTE External clock mode. 'r9d6KbpsNLE' means rate of 9.6 Kbps ('d'=dot). Note: Some rate attributes have been changed. As the MIB was already released with the old attributes, the names of the options were not changed. The new names + attributes are in a comment. Example: r2048KbpsE (63), -- r2048KbpsNLE
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), r32KbpsNLE(2), r48KbpsNLE(3), r56KbpsNLE(4), r64KbpsNLE(5), r112KbpsNLE(6), r128KbpsNLE(7), r168KbpsNLE(8), r192KbpsNLE(9), r224KbpsNLE(10), r256KbpsNLE(11), r280KbpsE(12), r320KbpsE(13), r336KbpsNLE(14), r384KbpsNLE(15), r392KbpsE(16), r448KbpsNLE(17), r504KbpsLE(18), r512KbpsE(19), r560KbpsE(20), r576KbpsLE(21), r616KbpsE(22), r640KbpsE(23), r672KbpsNLE(24), r704KbpsE(25), r728KbpsE(26), r768KbpsNLE(27), r784KbpsE(28), r832KbpsE(29), r840KbpsE(30), r896KbpsNLE(31), r952KbpsE(32), r960KbpsE(33), r1008KbpsLE(34), r1024KbpsE(35), r1064KbpsE(36), r1088KbpsE(37), r1120KbpsE(38), r1152KbpsLE(39), r1176KbpsE(40), r1216KbpsE(41), r1232KbpsE(42), r1280KbpsE(43), r1288KbpsE(44), r1344KbpsNLE(45), r1400KbpsE(46), r1408KbpsE(47), r1456KbpsE(48), r1472KbpsE(49), r1512KbpsE(50), r1536KbpsE(51), r1568KbpsE(52), r1600KbpsE(53), r1624KbpsE(54), r1664KbpsE(55), r1680KbpsE(56), r1728KbpsE(57), r1736KbpsE(58), r1792KbpsNLE(59), r1856KbpsE(60), r1920KbpsE(61), r1984KbpsE(62), r2048KbpsE(63), r9d6KbpsNLE(65), r14d4KbpsNLE(66), r16KbpsNLE(67), r19d2KbpsNLE(68), r28d8KbpsNLE(69), r38d4KbpsNLE(70), r57d6KbpsNLE(71), r115d2KbpsNLE(72), r24000bps(73)  

prtExPhPlLRate 1.3.6.1.4.1.164.3.2.3.2.3.1.1.6
This attribute indicates the port speed for LOW speed cards. The card has limitations about the possible rates for each clock mode. N - The rate is valid for DCE and EXT-DCE Nodal clock mode. L - The rate is valid for DCE and EXT-DCE Local clock mode. E - The rate is valid for DTE External clock mode. Note: Some rate attributes have been changed. As the MIB was already released with the old attributes, the names of the options were not changed. The new names + attributes are in a comment. Example: r57600bpsLE (16), -- r57600bpsNLE
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), r300bpsNLE(2), r600bpsNLE(3), r800bpsNLE(4), r1200bpsNLE(5), r2400bpsNLE(6), r4800bpsNLE(7), r9600bpsNLE(8), r14400bpsLE(9), r19200bpsNLE(10), r28800bpsLE(11), r32000bpsNLE(12), r38400bpsNLE(13), r48000bpsNLE(14), r56000bpsNLE(15), r57600bpsLE(16), r64000bpsNLE(17), r112000bps(18), r115200bps(19), r16000bpsNLE(20), r100bpsNLE(21), r128000bps(22), r24000bps(23)  

prtExPhPlProtocol 1.3.6.1.4.1.164.3.2.3.2.3.1.1.7
This object indicates the applied protocol.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER fr(1), frPlus(2), pCellRelay(3), hdlcSdlc(4), transparentHdlc(5), async(6), asyncReliable(7), activePPP(8), slip(9), pppAgent(10), slipAgent(11), transparent(12), sna(13)  

prtExPhPlConnectionTyp 1.3.6.1.4.1.164.3.2.3.2.3.1.1.8
This attribute indicates the link connection type. It is required for three reasons: FR/CR Inband management opration (LMI,CLMM...). CIR check. NMS network management. SameNetManaged - indicates network internal line. SameNetMotMana - indicates network internal line, but the remote mux is not managed by the NMS. User - User to Network Interface. OtherNet - Network To Network Interface. PubNet - Access Mux To PubNet Interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER sameNetManaged(1), sameNetNotMana(2), user(3), otherNet(4), pubNet(5), notApplicable(255)  

prtExPhPlClkMode 1.3.6.1.4.1.164.3.2.3.2.3.1.1.9
Clock mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dce(1), extDce(2), dte(3), int(4), lbt(5)  

prtExPhPlDceClkSrc 1.3.6.1.4.1.164.3.2.3.2.3.1.1.10
This attribute indicates the source of the clock when working in dce or ext-dce clock mode. notApplicable(1) - is applied for dte(3) and lbt(5) clock modes. When clock mode is dte, the clock source is always external, therefore this object's value is notApplicable. local(2) and nodalTiming(3) - are valid in dce(1), extDce(2) or int(4) clock modes. The recommended clock source is local(2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), local(2), nodalTiming(3)  

prtExPhPlCongResponse 1.3.6.1.4.1.164.3.2.3.2.3.1.1.11
This attribute indicates how to handle the congestion indication to/from the mux internal connection side (for example transmit/received becn to/from the network). no - do nothing flowControl - translates the congestion indication between the port and the internal connection port according to the definition of the prtInPh1MlFlowControl parameters. The operation is done on both directions. toFlowControl- translates the backward congestion indication received from the internal connection port (normally the network side) to flow control and do nothing in the other direction.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), flowControl(3), toFlowControl(4)  

prtExPhPlCongLevel 1.3.6.1.4.1.164.3.2.3.2.3.1.1.12
This attribute indicates the level of delayed data in precents of total available dynamic memory, for which the port will start to operate as congested. The resolution of the parameter is 5 percent.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..70  

prtExPhPlTc 1.3.6.1.4.1.164.3.2.3.2.3.1.1.13
This attribute indicates the Tc parameter which is the time period of the sliding window in which the Bc/Be are tested. The value of this parameter is identical for all the ports of a specific card .
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER tc1sec(1), tc2sec(2), tc3sec(3), tc4sec(4), notApplicable(255)  

prtExPhPlFlowControl 1.3.6.1.4.1.164.3.2.3.2.3.1.1.14
This attribute indicates the required flow control betweeen the port and the remote equipment. fecnBecn - is valid only for FR, FR+ and CR protocols. xonXoff,dtrCts - are valid only for Async protocols. speedReduction - is valid only for DLC protocol when the Clock Mode is DCE and the Clock Source is Local.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(2), fecnBecn(3), xonXoff(4), dtrCts(5), speedReduction(6)  

prtExPhPlDcdRts 1.3.6.1.4.1.164.3.2.3.2.3.1.1.15
Protocol may require end to end connect indication over the network. End to end link connection establishment over the FR network will be indicated to the user by using DCD or RTS control signals, depending on the clock mode: DCE or DTE respectively. The options are : - On : DCD(DCE)/RTS(DTE) will be constantly ON no matter if the End to End connection is established or not. - End to End: The DCD(DCE)/RTS(DTE) will be according to the status of the End to End connection.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), on(2), endToEnd(3)  

prtExPhPlDcdRtsControlPath 1.3.6.1.4.1.164.3.2.3.2.3.1.1.16
Protocol may require end to end connect indication over the network. This parameter defines whether to take the user connection status (RTS(DCE)/DCD(DTE)) and forward it to the network side. - on : Transmit active connection to the network regardless the RTS/DCD control lines status. - off: Transmit active connection to the network according to the status of the RTS/DCD pin.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3)  

prtExPhPlDataBits 1.3.6.1.4.1.164.3.2.3.2.3.1.1.17
This attribute indicates the number of data bits in async frame. It is relevant only for Async protocols.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), dataBits7Bits(2), dataBits8Bits(3)  

prtExPhPlParity 1.3.6.1.4.1.164.3.2.3.2.3.1.1.18
This attribute indicates the parity operation mode in async frame. It is relevant only for Async protocols.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), odd(2), even(3), none(4)  

prtExPhPlStopBits 1.3.6.1.4.1.164.3.2.3.2.3.1.1.19
This attribute indicates the minimum number of stop bits in the tx async frame. It is relevant only for Async protocols.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), sb1Bit(2), sb1dot5Bits(3), sb2Bits(4)  

prtExPhPlLXon 1.3.6.1.4.1.164.3.2.3.2.3.1.1.20
This attribute indicates the character used as X-On to notify receive enable. This parameter is valid only for async protocols. Valid values: 0..255. The value 256 indicates that it's not applicable
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

prtExPhPlLXoff 1.3.6.1.4.1.164.3.2.3.2.3.1.1.21
This attribute indicates the character used as X-Off to notify receive disable. This parameter is valid only for async protocols. Valid values: 0..255. The value 256 indicates that it's not applicable
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

prtExPhPlFrMngProt 1.3.6.1.4.1.164.3.2.3.2.3.1.1.22
This object indicates the Frame-Relay management protocol. ansiT1 = ANSI T1.617 Annex D (this is the default value). This parameter is applicable only for FR and FR+ protocols. When prtExPhPlConnectionTyp = sameNetManaged, this object will be RO (internally determined).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), lmi(3), ansiT1(4), annexA(5)  

prtExPhPlEnqPeriod 1.3.6.1.4.1.164.3.2.3.2.3.1.1.23
This object is the Status Enquiry Period, in seconds. It determines the frequency of the Status Enquiry message as sent by the FR user side. At the FR network side, it determines the timeout for this message reception. Default = 4 seconds. This parameter is applicable only for FR and FR+ protocols AND only when prtExPhPlFrMngProt is NOT (notApplicable or none).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..30  

prtExPhPlFullRptPeriod 1.3.6.1.4.1.164.3.2.3.2.3.1.1.24
This object is the Full Report Frequency. It determines the number of the Status Enquiry messages sent by the FR user side, before a Full Report Request is sent. The units are : Status Enquiry messages (periods). Valid values: 1 .. 255. 255 = infinite. This parameter is applicable only for FR and FR+ protocols AND only when prtExPhPlFrMngProt is NOT (notApplicable or none).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

prtExPhPlFrWindowSize 1.3.6.1.4.1.164.3.2.3.2.3.1.1.25
This object is the FR Window Size. It determines the number of samplings in the sliding window that counts the errors. This parameter is applicable only for FR and FR+ protocols AND only when prtExPhPlFrMngProt is NOT (notApplicable or none).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..10  

prtExPhPlErrorsThreshold 1.3.6.1.4.1.164.3.2.3.2.3.1.1.26
This object is the Max Errors. It determines the number of Status Enquiry Errors that occured within the FR sliding window, before this port is considered DOWN (threshold). This parameter is applicable only for FR and FR+ protocols AND only when prtExPhPlFrMngProt is NOT (notApplicable or none).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..10  

prtExPhPlPvcCreateMsg 1.3.6.1.4.1.164.3.2.3.2.3.1.1.27
This object is Update Message (if required or not). It determines whether a message of a New PVC Creation is requested or not (yes/no). Default = no. This parameter is applicable only for FR and FR+ protocols AND only when prtExPhPlFrMngProt is NOT (notApplicable or none).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtExPhPlCllmMsg 1.3.6.1.4.1.164.3.2.3.2.3.1.1.28
This object is CLLM Message (if required or not). It determines whether to send (or not) a congestion message when the port is Rx congested. Default = no. This parameter is applicable only for FR and FR+ protocols AND only when prtExPhPlFrMngProt is NOT (notApplicable or none).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtExPhPlProtDelayLevel 1.3.6.1.4.1.164.3.2.3.2.3.1.1.29
This object is the Segmentation in Bytes. In some cases, the enumerated values will mean other segmentation values than specified: Product: MX-3000 MX-3000 MX-300/MX-30 Protocol: FR+ Transparent FR+ ----------------------------------------------------- level 1 50 Bytes 44 Bytes 50 Bytes level 2 158 Bytes 155 Bytes 158 Bytes level 3 266 Bytes 266 Bytes 266 Bytes level 4 376 Bytes 377 Bytes 376 Bytes level 5 484 Bytes 488 Bytes 484 Bytes Defval=level 1 value This parameter is applicable only for FR+ and transparent protocols.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), s36Byte(2), s150Byte(3), s264Byte(4), s378Byte(5), s492Byte(6)  

prtExPhPlClockEncoding 1.3.6.1.4.1.164.3.2.3.2.3.1.1.30
This object is the Encoding type of the Line. This parameter is applicable only for FR and FR+ protocols.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), nrz(2), nrzI(3), fm0(4), manchester(5), diffManchester(6)  

prtExPhPlMinSeparators 1.3.6.1.4.1.164.3.2.3.2.3.1.1.31
Minimum number of bytes separating between two adjacent frames (HDLC item). 0 = notApplicable
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..16  

prtExPhPlCcittCrc 1.3.6.1.4.1.164.3.2.3.2.3.1.1.32
This object indicates how many Bits are used for CRC (HDLC item).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), crc16(2), crc32(3)  

prtExPhPlFrameSeparator 1.3.6.1.4.1.164.3.2.3.2.3.1.1.33
This object indicates what should be transferred on the line when there are no frames to pass (HDLC item). idles: mean that FF will pass on the line flags: mean that 7E will pass on the line.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), idles(2), flags(3)  

prtExPhPlDlciTable 1.3.6.1.4.1.164.3.2.3.2.3.2
The write operation into the Table Objects is valid only at the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExPhPlDlciEntry

prtExPhPlDlciEntry 1.3.6.1.4.1.164.3.2.3.2.3.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtExPhPlDlciEntry  

prtExPhPlDlciCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.3.2.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtExPhPlDlciSltIdx 1.3.6.1.4.1.164.3.2.3.2.3.2.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExPhPlDlciPrtIdx 1.3.6.1.4.1.164.3.2.3.2.3.2.1.3
This attribute indicates a unique internal port number. PH.1/E1 and PH.1/T1 cards have three internal ports. Stand-alone units may have six such ports.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6)  

prtExPhPlDlciIdx 1.3.6.1.4.1.164.3.2.3.2.3.2.1.4
This attribute indicates a unique index for each possible used dlci(16..991). When the protocol is not Multiplexing protocol, its type is 'user' and the only valid index is 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..991  

prtExPhPlDlciValid 1.3.6.1.4.1.164.3.2.3.2.3.2.1.5
This attribute indicates whether the attributes in this entry are valid or not. The user can add/delete pvc (dlci to dlci connection) by modifing this object
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExPhPlDlciIConSlt 1.3.6.1.4.1.164.3.2.3.2.3.2.1.6
This attribute indicates a unique slot position In the Mux (Agent) where the dlci is routed to. cl - will represent any of the CL slots. This value can be selected for multiple DLCIs of the product. In the ?004 Unit the entries io6(10)..io16) are not valid
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noConnect(2), cl(3), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExPhPlDlciIConPrt 1.3.6.1.4.1.164.3.2.3.2.3.2.1.7
This attribute indicates a unique port id which the dlci is routed to. clNMS - will be used for NMS SNMP messages. It can be any port of the CL card. This value will be selectable only if prtExPhPlDlciIConSlt='cl' or 'notApplicable'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), exPrt9(9), exPrt10(10), clNMS(99), noConnect(100), inPrt1(101), inPrt2(102), inPrt3(103), inPrt4(104), inPrt5(105), inPrt6(106), inPrt7(107), inPrt8(108), inPrt9(109), inPrt10(110)  

prtExPhPlDlciIConDlci 1.3.6.1.4.1.164.3.2.3.2.3.2.1.8
This attribute indicates a unique internal connection dlci number, the dlci is routed to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..991  

prtExPhPlDlciTxBc 1.3.6.1.4.1.164.3.2.3.2.3.2.1.9
This attribute indicates a unique Tx committed bandwidth on the user transmit line (or at the port receive line).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER full(1), zero(2), txBc9600bps(3), txBc14400bps(4), txBc19200bps(5), txBc28800bps(6), txBc32000bps(7), txBc38400bps(8), txBc48000bps(9), txBc56000bps(10), txBc57600bps(11), txBc64Kbps(12), txBc128Kbps(13), txBc192Kbps(14), txBc256Kbps(15), txBc320Kbps(16), txBc384Kbps(17), txBc448Kbps(18), txBc512Kbps(19), txBc768Kbps(20), txBc1024Kbps(21), txBc16000bps(25), txBc112Kbps(26)  

prtExPhPlDlciTxBe 1.3.6.1.4.1.164.3.2.3.2.3.2.1.10
This attribute indicates a unique Tx excess bandwidth on the user transmit line (or at the port receive line).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER full(1), zero(2), txBe9600bps(3), txBe14400bps(4), txBe19200bps(5), txBe28800bps(6), txBe32000bps(7), txBe38400bps(8), txBe48000bps(9), txBe56000bps(10), txBe57600bps(11), txBe64Kbps(12), txBe128Kbps(13), txBe192Kbps(14), txBe256Kbps(15), txBe320Kbps(16), txBe384Kbps(17), txBe448Kbps(18), txBe512Kbps(19), txBe768Kbps(20), txBe1024Kbps(21), txBc16000bps(25), txBc112Kbps(26)  

prtExPhPlDlciRxBc 1.3.6.1.4.1.164.3.2.3.2.3.2.1.11
This attribute indicates a unique Rx committed bandwidth on the user receive line (or at the port transmit line).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER full(1), zero(2), rxBc9600bps(3), rxBc14400bps(4), rxBc19200bps(5), rxBc28800bps(6), rxBc32000bps(7), rxBc38400bps(8), rxBc48000bps(9), rxBc56000bps(10), rxBc57600bps(11), rxBc64Kbps(12), rxBc128Kbps(13), rxBc192Kbps(14), rxBc256Kbps(15), rxBc320Kbps(16), rxBc384Kbps(17), rxBc448Kbps(18), rxBc512Kbps(19), rxBc768Kbps(20), rxBc1024Kbps(21), rxBc16000bps(25), rxBc112Kbps(26)  

prtExPhPlDlciRxBe 1.3.6.1.4.1.164.3.2.3.2.3.2.1.12
This attribute indicates a unique Rx excess bandwidth on the user receive line (or at the port transmit line).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER full(1), zero(2), rxBe9600bps(3), rxBe14400bps(4), rxBe19200bps(5), rxBe28800bps(6), rxBe32000bps(7), rxBe38400bps(8), rxBe48000bps(9), rxBe56000bps(10), rxBe57600bps(11), rxBe64Kbps(12), rxBe128Kbps(13), rxBe192Kbps(14), rxBe256Kbps(15), rxBe320Kbps(16), rxBe384Kbps(17), rxBe448Kbps(18), rxBe512Kbps(19), rxBe768Kbps(20), rxBe1024Kbps(21), rxBc16000bps(25), rxBc112Kbps(26)  

prtExPhPlDlciPriority 1.3.6.1.4.1.164.3.2.3.2.3.2.1.13
This attribute indicates a unique priority of the pcv. 1 is the lowest priority and 8 is the highest priority.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..8  

prtExPhPlDlciStatus 1.3.6.1.4.1.164.3.2.3.2.3.2.1.14
This attribute indicates the status of the pvc. The status is disconnected(1) when one of the sides is programmed as not connected
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disconnected(1), connected(2)  

prtExPhPlModemTable 1.3.6.1.4.1.164.3.2.3.2.3.3
External Modem Parameters. The write operation into the Table Objects is valid only for the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExPhPlModemEntry

prtExPhPlModemEntry 1.3.6.1.4.1.164.3.2.3.2.3.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtExPhPlModemEntry  

prtExPhPlModemCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.3.3.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtExPhPlModemSltIdx 1.3.6.1.4.1.164.3.2.3.2.3.3.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExPhPlModemPrtIdx 1.3.6.1.4.1.164.3.2.3.2.3.3.1.3
This attribute indicates a unique port number. In case of PH.1 card, only exPrt(1) is valid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6)  

prtExPhPlModemStatus 1.3.6.1.4.1.164.3.2.3.2.3.3.1.4
This object indicates whether a Dial Up Modem is enabled on this port. Default: disable
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

prtExPhPlModemActivate 1.3.6.1.4.1.164.3.2.3.2.3.3.1.5
This object indicates whether the Dial Up Modem is activated when the first frame is received or it is always activated. Default: onFirstFrame
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER onFirstFrame(2), always(3), notApplicable(255)  

prtExPhPlModemMaxIdleTime 1.3.6.1.4.1.164.3.2.3.2.3.3.1.6
Max Time allowed in Seconds without any traffic before the line is disconnected. Legal Values are: 1 sec, 2 sec .. 5 sec, 10 sec, 20 sec.. 1 min, 2 min .. 10 min, 15 min, 20 min, 25 min, 30 min. 65535 sec. means that this parameter is not applicable. Default: 1 sec.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

prtExPhPlModemTimeBtwnCalls 1.3.6.1.4.1.164.3.2.3.2.3.3.1.7
Minimum Time in Seconds which is required after a call was disconnected. In this time no other call will be initiated from this Modem port even if there were frames transmitted to this port. This time is required for some Modems which have initializations that take a few seconds. Legal Values are: 0 sec. - 30 sec., 1-5 min. 65535 sec. means that this parameter is not applicable. Default: 0 sec
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

prtExPhPlModemCallDelay 1.3.6.1.4.1.164.3.2.3.2.3.3.1.8
Time in Seconds that the device will wait before dialing to the remote device. This feature is mostly used when there is a backup modem to the main link and the main link is down. In this case it is important to prevent the 2 devices from dialing through the backup modems to each other at the same time. It is advised to configure one side with a small call delay and the other side with a large call delay. Legal Values are: 0 - 30, 60, 120, 180, 240, 300, 600, 900, 1200, 1500, 1800 . 65535 sec. means that this parameter is not applicable. Default: 0 sec
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

prtExLs2CnfgTable 1.3.6.1.4.1.164.3.2.3.2.4.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExLs2CnfgEntry

prtExLs2CnfgEntry 1.3.6.1.4.1.164.3.2.3.2.4.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtExLs2CnfgEntry  

prtExLs2CnfgIdx 1.3.6.1.4.1.164.3.2.3.2.4.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtExLs2SltIdx 1.3.6.1.4.1.164.3.2.3.2.4.1.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExLs2PrtIdx 1.3.6.1.4.1.164.3.2.3.2.4.1.1.3
This attribute indicates a unique port index. For the Ls2/X.58 exPrt(7)..exPrt(10) are not valid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), exPrt9(9), exPrt10(10)  

prtExLs2Connect 1.3.6.1.4.1.164.3.2.3.2.4.1.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExLs2Rate 1.3.6.1.4.1.164.3.2.3.2.4.1.1.5
Port rates.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER r2400bps(2), r4800bps(3), r9600bps(4), r19200bps(5)  

prtExLs2ClkMode 1.3.6.1.4.1.164.3.2.3.2.4.1.1.6
This attribute indicates a unique port operation clock mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dce(1), ext-dce(2), dte(3)  

prtExLs2Cts 1.3.6.1.4.1.164.3.2.3.2.4.1.1.7
CTS.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(2), rts-min(3), rts-max(4)  

prtExLs2Dcd 1.3.6.1.4.1.164.3.2.3.2.4.1.1.8
DCD.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(2), card-sync(3)  

prtExLs2EnvIdx 1.3.6.1.4.1.164.3.2.3.2.4.1.1.9
Envelope Index. When prtInLs2EnvAssign=auto, the value is 0 (not applicable).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..24  

prtInLs2CnfgTable 1.3.6.1.4.1.164.3.2.3.2.4.2
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtInLs2CnfgEntry

prtInLs2CnfgEntry 1.3.6.1.4.1.164.3.2.3.2.4.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtInLs2CnfgEntry  

prtInLs2CnfgIdx 1.3.6.1.4.1.164.3.2.3.2.4.2.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtInLs2SltIdx 1.3.6.1.4.1.164.3.2.3.2.4.2.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtInLs2PrtIdx 1.3.6.1.4.1.164.3.2.3.2.4.2.1.3
This attribute indicates a unique internal port index.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER inPrt1(101), inPrt2(102)  

prtInLs2Connect 1.3.6.1.4.1.164.3.2.3.2.4.2.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms. It also affects all the module considerations because the module has only one Internal interface which is the composite channel.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtInLs2Group 1.3.6.1.4.1.164.3.2.3.2.4.2.1.5
This attribute indicates the group number of the port. LS-2 internal ports with the same group number share the same Time slot of the main link
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..12  

prtInLs2Member 1.3.6.1.4.1.164.3.2.3.2.4.2.1.6
This attribute indicates the group member id of the port. This parameter is for the automatic envelope assignment algorithm.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..4  

prtInLs2LinkTo 1.3.6.1.4.1.164.3.2.3.2.4.2.1.7
It indicates the slot of the main link card to which the LS2 card is mapped. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
Status: deprecated Access: read-write
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtInLs2EnvAssign 1.3.6.1.4.1.164.3.2.3.2.4.2.1.8
Envelope assignment type.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER auto(2), manual(3)  

prtVc2CnfgTable 1.3.6.1.4.1.164.3.2.3.2.5
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtVc2CnfgEntry

prtVc2CnfgEntry 1.3.6.1.4.1.164.3.2.3.2.5.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtVc2CnfgEntry  

prtVc2CnfgIdx 1.3.6.1.4.1.164.3.2.3.2.5.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtVc2SltIdx 1.3.6.1.4.1.164.3.2.3.2.5.1.2
This attribute indicates a unique slot position where the card is inserted. For Stand Alone products like WR: notApplicable (255)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtVc2PrtIdx 1.3.6.1.4.1.164.3.2.3.2.5.1.3
A unique identifier of the port, within the card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), exPrt9(9), exPrt10(10), exPrt11(11), exPrt12(12)  

prtExVc2Connect 1.3.6.1.4.1.164.3.2.3.2.5.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExVc2TransGain 1.3.6.1.4.1.164.3.2.3.2.5.1.5
Transmit gain in dBm. For ports of VC-6A and VC-6AG cards, the units will be 0.1dBm because valid values can be in 0.5dBm steps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

prtExVc2ReceiveGain 1.3.6.1.4.1.164.3.2.3.2.5.1.6
Receive gain in dBm. For ports of VC-6A and VC-6AG cards, the units will be 0.1dBm because valid values can be in 0.5dBm steps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

prtExVc2Wire 1.3.6.1.4.1.164.3.2.3.2.5.1.7
This object is equal for all the ports in the specific card because of HW limitations. For FXO & FXS this parameter is not applicable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER w2wire(1), w4wire(2), notApplicable(255)  

prtExVc2CodingLaw 1.3.6.1.4.1.164.3.2.3.2.5.1.8
This attribute indicates the Method/Law for decoding/encoding the voice information. aLaw(1) is the standard Law for E1 links. uLaw(2) is the standard Law for T1 links. This object is equal for all the ports in the specific module because of HW limitations
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER aLAW(1), uLAW(2)  

prtExVc2Sig 1.3.6.1.4.1.164.3.2.3.2.5.1.9
This attribute indicates the method for decoding/encoding the signaling information(on/off hook). noSignaling (1) - not using signaling (only voice). robbedBitMultiFrame(2) - is the standard method for T1 links and proprietary method for E1 links. chAssociatedE1 (3) - is valid only for E1 G.732S links. robbedBitFrame (4) - is proprietary method implimenting 7 bit for the voice and 1 bit dedicated for signaling. This object is equal for all the ports in the specific module because of HW limitations.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noSignaling(1), robbedBitMultiFrame(2), chAssociatedE1(3), robbedBitFrame(4)  

prtExVc2Oos 1.3.6.1.4.1.164.3.2.3.2.5.1.10
This object is equal for all the ports in the specific card because of HW limitations
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER forcedIdle(1), forcedBusy(2), busyIdle(3), idleBusy(4), notApplicable(5)  

prtExVc2LinkTo 1.3.6.1.4.1.164.3.2.3.2.5.1.11
This attribute indicates the slot of the ML card to which the VC card is mapped. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
Status: deprecated Access: read-write
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExVc2OperMode 1.3.6.1.4.1.164.3.2.3.2.5.1.12
This object indicates the operation mode of the port. normal = bi-directional (Tx/Rx) unidirectRx = unidirectional Rx. broadcast = Tx upon request.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(2), unidirectRx(3), broadcast(4)  

prtExVc2SigProfile 1.3.6.1.4.1.164.3.2.3.2.5.1.13
This object indicates the Signaling Profile of the port. notApplicable - for VC-2 family and when prtExVc2Sig=noSignaling(1) p1 = profile 1 p2 = profile 2 p3 = profile 3 p4 = profile 4
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), manual(2), p1(3), p2(4), p3Fxo3S3(5), reversePolarity(6), meteringPulse(7), p4(8)  

prtExVc2CallEnable 1.3.6.1.4.1.164.3.2.3.2.5.1.14
This object indicates the Enabled Call direction. notApplicable - for all cards except VC-2/R2. both - incoming + outgoing.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), incoming(2), outgoing(3), both(4)  

prtExVc2R2Delay 1.3.6.1.4.1.164.3.2.3.2.5.1.15
This object indicates the R2 Delay. notApplicable - for all cards except VC-2/R2.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), terrestrial(2), satellite(3)  

prtExVc2CasStd 1.3.6.1.4.1.164.3.2.3.2.5.1.16
This object indicates the CAS (Channel Associated Signaling) Standard. notApplicable - for all cards except VC-2/R2.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), r2Q422(2), specialA(3), specialB(4), specialC(5), specialD(6), specialE(7), specialF(8), specialG(9)  

prtExVc2EchoCanceler 1.3.6.1.4.1.164.3.2.3.2.5.1.17
Echo canceler activation. notApplicable - for VC-2 and VC-6 cards.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3)  

prtExVc2IfType 1.3.6.1.4.1.164.3.2.3.2.5.1.18
Interface Type.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), w2Em(2), w4Em(3), fxo(4), fxs(5)  

prtExVc2Encoding 1.3.6.1.4.1.164.3.2.3.2.5.1.19
Voice Encoding Mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), pcm(2), adpcm(3)  

prtExVc2TxBitCode 1.3.6.1.4.1.164.3.2.3.2.5.1.20
- - - For MP & FCD - - - This object represents 4 parameters, by 2 Octets : Tx D Bit Code-MSB nibble, Tx C Bit Code- nibble, Tx B Bit Code- nibble, Tx A Bit Code-LSB nibble. Each nibble: 0 hex = 0000 = Not Applicable 1 hex = 0001 = M lead 2 hex = 0010 = M lead inverse 3 hex = 0011 = Reverse Polarity 4 hex = 0100 = Metering Pulse 5 hex = 0101 = Forced 1 6 hex = 0110 = Forced 0 7-F hex - not used (invalid values) This object will be RO if prtExVc2SigProfile is NOT manual. - - - For WR II - - - This object represents the following 4 parameters by 2 Octets: 1. On/Off hook signaling transmission mode from the FXS towards the T1/E1 (MSB nibble 1). 2. Default signaling bits that are not in use (nibble 2). 3. Ring Detection signaling transmission mode from the FXO towards the T1/E1(nibble 3). 4. M (Mouth) Signaling transmission mode from the E&M towards the T1/E1(LSB nibble 4). Each nibble: --------------------------------------------------------------------------------------- Value On/Off Hook Default sig. Ring Detect. M (Mouth) --------------------------------------------------------------------------------------- 0 hex = 0000 Not Applicable Not Applicable. Not Applicable Not Applicable 1 hex = 0001 Tx A bit Values 1-3 are Tx A bit Tx A bit 2 hex = 0010 Tx A bit inverse for On/Off Hook Tx A bit inv. Tx A bit inv. 3 hex = 0011 Tx B bit A,B,A Inv,B Inv. Tx B bit Tx B bit 4 hex = 0100 Tx B bit inverse Values 4-7 are Tx B bit inv. Tx B bit inv. 5 hex = 0101 not Used-invalid for On/Off Hook not Used-invalid not Used-invalid 6 hex = 0110 not Used-invalid A, A Inverse. not Used-invalid not Used-invalid 7 hex = 0111 not Used-invalid not Used-invalid not Used-invalid 8 hex = 1000 not Used-invalid Values 8-11 are not Used-invalid not Used-invalid 9 hex = 1001 not Used-invalid for On/Off Hook not Used-invalid not Used-invalid A hex = 1010 not used-invalid B, B Inverse. not Used-invalid not Used-invalid B hex = 1011 not used-invalid The Bits order: not Used-invalid not Used-invalid C-F hex not used-invalid ABCD not Used-invalid not Used-invalid Default value: 11 11
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

prtExVc2RxBitOutput 1.3.6.1.4.1.164.3.2.3.2.5.1.21
- - - For MP & FCD - - - This object represents 3 parameters by 2 Octets: Spare -MSB nibble, always=0 hex E Lead Output - nibble, Reverse Polarity Output- nibble, Metering Pulse Output -LSB nibble. Each nibble: 0 hex = 0000 = Not Applicable 1 hex = 0001 = Rx A bit 2 hex = 0010 = Rx A bit inverse 3 hex = 0011 = Rx B bit 4 hex = 0100 = Rx B bit inverse 5 hex = 0101 = Rx C bit 6 hex = 0110 = Rx C bit inverse 7 hex = 0111 = Rx D bit 8 hex = 1000 = Rx D bit inverse 9 hex = 1001 = none A-F hex - not used (invalid values) This object will be RO if prtExVc2SigProfile is NOT manual. - - - For WR II - - - This object represents the following 2 parameters in 1 Octet: 1. On/Off hook signaling receive mode from the T1/E1 into the FXS/FXO (MSB nibble 1). 2. E (Ear) Signaling receive mode from the T1/E1 into the E&M (LSB nibble 2). Each nibble: --------------------------------------------------------------------------------------- Value On/Off Hook E (Ear) --------------------------------------------------------------------------------------- 0 hex = 0000 Not Applicable Not Applicable 1 hex = 0001 Rx A bit Rx A bit 2 hex = 0010 Rx A bit inverse Rx A bit inverse 3 hex = 0011 Rx B bit Rx B bit 4 hex = 0100 Rx B bit inverse Rx B bit inverse 5-F hex not used-invalid not Used-invalid Default value: 11
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

prtExVc2MeterRate 1.3.6.1.4.1.164.3.2.3.2.5.1.22
This entry is applicable only for VC-6A/FXO and VC-6A/FXS. Meter Rate means rate of Call Meter in Public Phones, in KHz units. Must be the same for all card's ports.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), r16Khz(2), r12Khz(3)  

prtExVc2IfSignaling 1.3.6.1.4.1.164.3.2.3.2.5.1.23
This entry is applicable only for VC-6A and VC-6AG cards. Interface Analog Signaling. Must be the same for all card's ports. loopStart - for the usual trunk/phone types. groundStart - for trunks that need Ground signaling (applicable for VC-6AG cards.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), loopStart(2), groundStart(3)  

prtExVc2SeizeAck 1.3.6.1.4.1.164.3.2.3.2.5.1.24
This parameter shows whether the device will acknowledge a seize signal (On/Off Hook). When the value is set to yes(3) & the device receives an on/off hook signal it will transmit back an on/off hook signal. When the value is set to no(2) & the device receives an on/off hook signal it will NOT transmit back an on/off hook signal. Default value for WR FXO: no(2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtExVc2EandMType 1.3.6.1.4.1.164.3.2.3.2.5.1.25
This is the signaling type on the E&M analog side. The analog signaling includes voltage, no. of pins and other parameters.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), type1(2), type2(3), type3(4), type5(5)  

prtHsfCnfgTable 1.3.6.1.4.1.164.3.2.3.2.6
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtHsfCnfgEntry

prtHsfCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.6.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtHsfCnfgEntry  

prtHsfCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.6.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relate to the TmpCnfg.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtHsfSltIdx 1.3.6.1.4.1.164.3.2.3.2.6.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtHsfPrtIdx 1.3.6.1.4.1.164.3.2.3.2.6.1.3
This attribute indicates a unique external port index. Hs2 has only two ports (exPrt1,exPrt2). Hs3 has three ports (exPrt1,exPrt2,exPrt3). Hsq and hsqN has four ports. Hs6 has six external ports. Hs12 has twelve external ports.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), exPrt9(9), exPrt10(10), exPrt11(11), exPrt12(12)  

prtExHsfConnect 1.3.6.1.4.1.164.3.2.3.2.6.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExHsfRate 1.3.6.1.4.1.164.3.2.3.2.6.1.5
This attribute indicates the port speed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER r1x56eq56Kbps(1), r1x64eq64Kbps(2), r2x56eq112Kbps(3), r2x64eq128Kbps(4), r3x56eq168Kbps(5), r3x64eq192Kbps(6), r4x56eq224Kbps(7), r4x64eq256Kbps(8), r5x56eq280Kbps(9), r5x64eq320Kbps(10), r6x56eq336Kbps(11), r6x64eq384Kbps(12), r7x56eq392Kbps(13), r7x64eq448Kbps(14), r8x56eq448Kbps(15), r8x64eq512Kbps(16), r9x56eq504Kbps(17), r9x64eq576Kbps(18), r10x56eq560Kbps(19), r10x64eq640Kbps(20), r11x56eq616Kbps(21), r11x64eq704Kbps(22), r12x56eq672Kbps(23), r12x64eq768Kbps(24), r13x56eq728Kbps(25), r13x64eq832Kbps(26), r14x56eq784Kbps(27), r14x64eq896Kbps(28), r15x56eq840Kbps(29), r15x64eq960Kbps(30), r16x56eq896Kbps(31), r16x64eq1024Kbps(32), r17x56eq952Kbps(33), r17x64eq1088Kbps(34), r18x56eq1008Kbps(35), r18x64eq1152Kbps(36), r19x56eq1064Kbps(37), r19x64eq1216Kbps(38), r20x56eq1120Kbps(39), r20x64eq1280Kbps(40), r21x56eq1176Kbps(41), r21x64eq1344Kbps(42), r22x56eq1232Kbps(43), r22x64eq1408Kbps(44), r23x56eq1288Kbps(45), r23x64eq1472Kbps(46), r24x56eq1344Kbps(47), r24x64eq1536Kbps(48), r25x56eq1400Kbps(49), r25x64eq1600Kbps(50), r26x56eq1456Kbps(51), r26x64eq1664Kbps(52), r27x56eq1512Kbps(53), r27x64eq1728Kbps(54), r28x56eq1568Kbps(55), r28x64eq1792Kbps(56), r29x56eq1624Kbps(57), r29x64eq1856Kbps(58), r30x56eq1680Kbps(59), r30x64eq1920Kbps(60), r31x56eq1736Kbps(61), r31x64eq1984Kbps(62), r32Kbps(63)  

prtExHsfClkMode 1.3.6.1.4.1.164.3.2.3.2.6.1.6
This attribute indicates a unique port operation clock mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dce(1), ext-dce(2), dte(3), none(4)  

prtExHsfCts 1.3.6.1.4.1.164.3.2.3.2.6.1.7
This attribute indicates a unique CTS control line operation mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), on(2), rts(3)  

prtExHsfFifoSize 1.3.6.1.4.1.164.3.2.3.2.6.1.8
Size in bits.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER auto(2), s16bits(3), s30bits(4), s52bits(5), s72bits(6)  

prtExHsfLinkTo 1.3.6.1.4.1.164.3.2.3.2.6.1.9
This attribute indicates a slot of Main Link module, that the port is linked to. This object is the same for all the ports in the specific card because of HW limitations. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
Status: deprecated Access: read-write
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExHsfOperMode 1.3.6.1.4.1.164.3.2.3.2.6.1.10
This object indicates the operation mode of the port. normal = bi-directional (Tx/Rx) unidirectRx = unidirectional Rx. broadcast = Tx upon request.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(2), unidirectRx(3), broadcast(4)  

prtExHsfInbandLoopback 1.3.6.1.4.1.164.3.2.3.2.6.1.11
This object indicates if Inband Loopback from the Network should be enabled or disabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), ft1Enabled(3)  

prtExHsfClkPolarity 1.3.6.1.4.1.164.3.2.3.2.6.1.12
This object indicates the clock polarity. For FCD-M this object will be applicable only for the fixed HS port (the fixed port on the device).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), normal(2), invert(3)  

prtExHs4CnfgTable 1.3.6.1.4.1.164.3.2.3.2.7.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExHs4CnfgEntry

prtExHs4CnfgEntry 1.3.6.1.4.1.164.3.2.3.2.7.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtExHs4CnfgEntry  

prtExHs4CnfgIdx 1.3.6.1.4.1.164.3.2.3.2.7.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtExHs4SltIdx 1.3.6.1.4.1.164.3.2.3.2.7.1.1.2
This attribute indicates a unique slot position where the card is inserted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExHs4PrtIdx 1.3.6.1.4.1.164.3.2.3.2.7.1.1.3
A unique identifier of the port, within the card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1)  

prtExHs4Connect 1.3.6.1.4.1.164.3.2.3.2.7.1.1.4
This attribute indicates whether the port should be considered in any of the mux algorithm. It also affects all the module considerations because the card has only one external (physical) interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExHs4LineType 1.3.6.1.4.1.164.3.2.3.2.7.1.1.5
This attribute is the line type parameter for T1/E1 interface. The user should select only the parameters relevant to the specific card: T1 line code parameters for the HS-4/1 and E1 line code parameters for the HS-4/2. This parameter has the same values as dsx1LineType in T1/E1 MIB (RFC-1406). The parameters in dsx1LineType are: other (1) dsx1ESF (2) dsx1D4 (3) dsx1E1 (4) dsx1E1-CRC (5) dsx1E1-MF (6) dsx1E1-MF-CRC (7)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER esfT1(2), sfT1(3), g732nE1(4), g732nE1CRC(5), g732sE1(6), g732sE1CRC(7)  

prtExHs4LineCode 1.3.6.1.4.1.164.3.2.3.2.7.1.1.6
This attribute is the line code parameter used for T1/E1 interface. The user should select only the parameters relevant to the specific card: T1 line code parameters for the MPH.1/T1 and E1 line code parameters for the MPH.1/E1. This parameter has the same values as dsx1LineCoding in T1/E1 MIB (RFC-1406). The parameters in dsx1LineCoding are: dsx1JBZS (1) dsx1B8ZS (2) dsx1HDB3 (3) dsx1ZBTSI (4) dsx1AMI (5) other (6)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER b7T1(1), b8zsT1(2), hdb3E1(4)  

prtExHs4LineLen 1.3.6.1.4.1.164.3.2.3.2.7.1.1.7
This attribute is the line length parameter used only for T1 interfaces. len399p533ft=len-399-533ft
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), len0p133ft(2), len134p266ft(3), len267p399ft(4), len400p533ft(5), len534p655ft(6), fcc68(7)  

prtExHs4RestoreT 1.3.6.1.4.1.164.3.2.3.2.7.1.1.8
Time passing from the disappearance of the loss of synchronization condition (red alarm), to the restoration of normal service.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER restoreT1secFast(2), restoreT10sec62411(3), ccittE1(4)  

prtExHs4OosSig 1.3.6.1.4.1.164.3.2.3.2.7.1.1.9
Out of Service signal type.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notsupported(2), forcedIdle(3), forcedBusy(4), busyIdle(5), idleBusy(6)  

prtExHs4OosCode 1.3.6.1.4.1.164.3.2.3.2.7.1.1.10
OOS Code
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notsupported(2), oosCode00H(3), oosCode1aH(4), oosCode54H(5), oosCode7eH(6), oosCode7fH(7), oosCode98H(8), oosCode9eH(9), oosCoded5H(10), oosCodee4H(11), oosCodeffH(12)  

prtExHs4IdleCode 1.3.6.1.4.1.164.3.2.3.2.7.1.1.11
Type value(00 - FF HEX), excluding 0H,8H,10H,12H,21H,24H, 42H,49H,84H,92H
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

prtExHs4MfClkSrcSlt 1.3.6.1.4.1.164.3.2.3.2.7.1.1.12
This attribute indicates whether the port Tx is multiframe synchronized with Rx multiframe of another port and the slot position of that port. This opration is required in order to bypass signaling of PCM voice channels. When its value is Local(2) there is no meaning to 'prtExHs4MfClkSrcPrt' parameter. In the ?004 Unit the entries io6(10)..io16) are not valid
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER local(2), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExHs4MfClkSrcPrt 1.3.6.1.4.1.164.3.2.3.2.7.1.1.13
A unique number to identify a port position in the mux if the MultiFrame clock source is valid (YES). inPrt1 - for MTML-H/E1 cards.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), inPrt1(101)  

prtExHs4TsCnfgTable 1.3.6.1.4.1.164.3.2.3.2.7.2
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExHs4TsEntry

prtExHs4TsEntry 1.3.6.1.4.1.164.3.2.3.2.7.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtExHs4TsEntry  

prtExHs4TsCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.7.2.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtExHs4TsSltIdx 1.3.6.1.4.1.164.3.2.3.2.7.2.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExHs4TsPrtIdx 1.3.6.1.4.1.164.3.2.3.2.7.2.1.3
This attribute indicates a unique port number. Hs4/T1 and Hs4/T1 cards have only one external interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1)  

prtExHs4TsIdx 1.3.6.1.4.1.164.3.2.3.2.7.2.1.4
This attribute indicates a unique time slot position. The valid time slots are: 1..24 for T1 Card and 1..31 for E1 interface. In G732S-E1 lines, time slot 16 is not valid for data, it is dedicated to multiframe synchronization bits and voice signaling.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtExHs4TsIConSlot 1.3.6.1.4.1.164.3.2.3.2.7.2.1.5
This attribute indicates whether the specified time slot is connected/routed internally in the Agent and to which card it is connected. In the ?004 Unit the entries io6(10)..io16) are not valid. split - will be used when the Src TS is connected to more than one slot OR more than one port (each needing less than a whole TS).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noConnect(2), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), split(100)  

prtExHs4TsIConPrt 1.3.6.1.4.1.164.3.2.3.2.7.2.1.6
This attribute indicates the internally (In Mux) connected/routed port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), exPrt9(9), exPrt10(10), exPrt11(11), exPrt12(12), noConnect(100)  

prtExHs4TsIConTs 1.3.6.1.4.1.164.3.2.3.2.7.2.1.7
This attribute indicates a unique time slot position. The valid time slots are: 1..24 for T1 Module and 1..31 for E1 interface. In G732S-E1 lines time slot 16 is not valid for data, it is dedicated for multiframe synchronization bits and voice signaling.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

prtExHsiCnfgTable 1.3.6.1.4.1.164.3.2.3.2.8.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExHsiCnfgEntry

prtExHsiCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.8.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtExHsiCnfgEntry  

prtExHsiCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.8.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtExHsiSltIdx 1.3.6.1.4.1.164.3.2.3.2.8.1.1.2
This attribute indicates a unique slot position where the card is inserted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExHsiPrtIdx 1.3.6.1.4.1.164.3.2.3.2.8.1.1.3
A unique prt identifier within the card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), exPrt9(9), exPrt10(10), exPrt11(11), exPrt12(12)  

prtExHsiConnect 1.3.6.1.4.1.164.3.2.3.2.8.1.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms. v51 - this port is connected to a V5.1 interface. All rest of the values will be 'notApplicable' in this case. V5.1 MIB will be used instead.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3), v51(4)  

prtExHsiRate 1.3.6.1.4.1.164.3.2.3.2.8.1.1.5
This attribute indicates the port speed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER r600bps(2), r1200bps(3), r2400bps(4), r4800bps(5), r9600bps(6), r19200bps(7), r38400bps(8), r48kbps(9), r56kbps(10), r64kbps(11), r128kbps(12), notApplicable(255)  

prtExHsiLinkTo 1.3.6.1.4.1.164.3.2.3.2.8.1.1.6
It indicates the slot of the main link card to which the HS-? card is mapped. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
Status: deprecated Access: read-write
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExHsiInterface 1.3.6.1.4.1.164.3.2.3.2.8.1.1.7
It indicates the interface type: lt = line termination nt = network termination te = terminal equipment. lt1 - for ASMi-31 connection (not ISDN) For HS-U/I and HS-U/1 only 'lt' and 'nt' are applicable. For HS-S , only 'te' and 'nt' are applicable. For HS-U, this object is not applicable. For HS-U6, HS-U12, are applicable: 'lt'=lt-i,'nt'=nt-i, lt1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER lt(1), nt(2), te(3), lt1(4), notApplicable(255)  

prtExHsiActType 1.3.6.1.4.1.164.3.2.3.2.8.1.1.8
It indicates the Activation Type. Activation Type is the Synchronization type towards the PBX. It is applicable only when prtExHsiInterface=nt. notApplicable - for cards that do not support this object, or when prtExHsiInterface is NOT nt.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), type1(2), type2(3), type3(4)  

prtInHsiCnfgTable 1.3.6.1.4.1.164.3.2.3.2.8.2
The write operation into the Table Objects is valid only to the TmpCnfg entry. This table is not applicable for HS-U card type.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtInHsiCnfgEntry

prtInHsiCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.8.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtInHsiCnfgEntry  

prtInHsiCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.8.2.1.1
This object indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtInHsiSltIdx 1.3.6.1.4.1.164.3.2.3.2.8.2.1.2
This object indicates a unique slot position where the card is inserted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtInHsiPrtIdx 1.3.6.1.4.1.164.3.2.3.2.8.2.1.3
A unique port identifier within the card. Valid values: inPrt1 (101) .. inPrt48 (148).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtInHsiConnect 1.3.6.1.4.1.164.3.2.3.2.8.2.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtInHsiRate 1.3.6.1.4.1.164.3.2.3.2.8.2.1.5
This object indicates the port speed. For HS-U/I and HS-S ports: 2 bit - up to 9600bps 4 bit - 19200bps 8 bit - 38400bps .. 64kbps. concentrated - this D channel goes to a Concentration channel, that represents many channels that this value was selected for them. The Concentrated channel is an Internal D Channel of the same card. This value is applicable only for D channels, except Concentration channel itself. --for HS-S and HS-U/I cards the Concentration channel will always be: internal-13 --for HS-S12, HS-S6, HS-U12, HS-U6, the Concentration channel is selected via the prtInHsiConcentratedTo object.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER r600bps(2), r1200bps(3), r2400bps(4), r4800bps(5), r9600bps(6), r19200bps(7), r38400bps(8), r48kbps(9), r56kbps(10), r64kbps(11), r128kbps(12), concentrated(13), notApplicable(255)  

prtInHsiConcentratedTo 1.3.6.1.4.1.164.3.2.3.2.8.2.1.6
The Concentration D Channel of the prtInHsiPrtIdx port. The port always belongs to the same card as prtInHsiPrtIdx port. This object is applicable only when prtInHsiRate=concentrated. Valid values: - notApplicable: 255 - for HS-S12, HS-U12 cards: inPrt37 (137) .. inPrt48 (148).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

prtExHsrCnfgTable 1.3.6.1.4.1.164.3.2.3.2.10.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExHsrCnfgEntry

prtExHsrCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.10.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtExHsrCnfgEntry  

prtExHsrCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.10.1.1.1
This object indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtExHsrSltIdx 1.3.6.1.4.1.164.3.2.3.2.10.1.1.2
This object indicates a unique slot position where the card is inserted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExHsrPrtIdx 1.3.6.1.4.1.164.3.2.3.2.10.1.1.3
A unique prt identifier within the card. Valid values: - For HS-R cards: exPrt1 (1) .. exPrt4 (4) - For HS-U/1 cards: inPrt1 (101) .. inPrt4 (104) - For HS-S12, HS-S6, HS-U12, HS-U6 cards: exPrt1 (1) .. exPrt12 (12). This MIB table is used only for LT-1 interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtExHsrConnect 1.3.6.1.4.1.164.3.2.3.2.10.1.1.4
This object indicates whether the port should be considered in any of the mux algorithms.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExHsrProtocol 1.3.6.1.4.1.164.3.2.3.2.10.1.1.5
This object indicates the protocol.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER sync(2), async(3)  

prtExHsrRate 1.3.6.1.4.1.164.3.2.3.2.10.1.1.6
This object indicates the port speed. The 16,32,48,56,64 and 128 kbps rates are applicable only for Sync protocol. The 57.6 and 115.2 kbps rates are applicable only for Async protocol.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER r600bps(2), r1200bps(3), r2400bps(4), r4800bps(5), r9600bps(6), r19200bps(7), r38400bps(8), r48kbps(9), r56kbps(10), r64kbps(11), r16000bps(12), r32000bps(13), r57600bps(14), r115200bps(15), r128000bps(16)  

prtExHsrDataBits 1.3.6.1.4.1.164.3.2.3.2.10.1.1.7
Data Bits. This object is applicable for Async protocol only.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER d5bits(1), d6bits(2), d7bits(3), d8bits(4), notApplicable(255)  

prtExHsrParity 1.3.6.1.4.1.164.3.2.3.2.10.1.1.8
- For HS-R card, this object indicates if the parity bit is needed or not. Therefore, the 'no' and 'yes; values are applicable. - For HS-S12, HS-U12, the parity type is selected: no, odd, even. This object is applicable for Async protocol only.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3), odd(4), even(5), notApplicable(255)  

prtExHsrStopBits 1.3.6.1.4.1.164.3.2.3.2.10.1.1.9
This object indicates the minimum number of stop bits in the tx async frame. This object is applicable for Async protocol only.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER stopBits1Bit(1), stopBits2Bits(2), notApplicable(255)  

prtExHsrCts 1.3.6.1.4.1.164.3.2.3.2.10.1.1.10
CTS. This object is applicable for Async protocol only.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(2), rts(3), notApplicable(255)  

prtExHsrClkMode 1.3.6.1.4.1.164.3.2.3.2.10.1.1.11
Clock mode. This object is applicable for Sync protocol only.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dce(1), extDce(2), notApplicable(255)  

prtExHsrLinkTo 1.3.6.1.4.1.164.3.2.3.2.10.1.1.12
It indicates the slot of the main link card to which the HS-R card is mapped. notApplicable - for HS-U/1 internal ports. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
Status: deprecated Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExHsrDcdDsr 1.3.6.1.4.1.164.3.2.3.2.10.1.1.13
DCD & DSR.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), local(2), endToEnd(3)  

prtExHsrOperMode 1.3.6.1.4.1.164.3.2.3.2.10.1.1.14
This object indicates the operation mode of the port. normal = bi-directional (Tx/Rx) unidirectRx = unidirectional Rx. broadcast = Tx upon request.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(2), unidirectRx(3), broadcast(4)  

prtExHsrRtsDtr 1.3.6.1.4.1.164.3.2.3.2.10.1.1.15
RTS & DTR.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), local(2), endToEnd(3)  

prtExHsrLlbEnable 1.3.6.1.4.1.164.3.2.3.2.10.1.1.16
Enable/Disable LLB.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

prtExHsrRlbEnable 1.3.6.1.4.1.164.3.2.3.2.10.1.1.17
Enable/Disable RLB.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

prtExHsrRateAdapt 1.3.6.1.4.1.164.3.2.3.2.10.1.1.18
Rate Adaptation - takes a low rate and adapts it to 64Kbps. This object specifies the means this adaptation is done by.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), proprietary(2), v110(3)  

prtExMbeCnfgTable 1.3.6.1.4.1.164.3.2.3.2.11.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExMbeCnfgEntry

prtExMbeCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.11.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtExMbeCnfgEntry  

prtExMbeCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.11.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtExMbeSltIdx 1.3.6.1.4.1.164.3.2.3.2.11.1.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExMbePrtIdx 1.3.6.1.4.1.164.3.2.3.2.11.1.1.3
A unique port identifier within the card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1)  

prtExMbeLan 1.3.6.1.4.1.164.3.2.3.2.11.1.1.4
This attribute indicates whether the MBE port is operated as main or remote bridge.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER remote(1), main(2)  

prtInMbeCnfgTable 1.3.6.1.4.1.164.3.2.3.2.11.2
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtInMbeCnfgEntry

prtInMbeCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.11.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtInMbeCnfgEntry  

prtInMbeCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.11.2.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtInMbeSltIdx 1.3.6.1.4.1.164.3.2.3.2.11.2.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtInMbePrtIdx 1.3.6.1.4.1.164.3.2.3.2.11.2.1.3
A unique port identifier within the card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER inPrt1(101)  

prtInMbeConnect 1.3.6.1.4.1.164.3.2.3.2.11.2.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtInMbeRate 1.3.6.1.4.1.164.3.2.3.2.11.2.1.5
This attribute indicates the port speed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER r1x64eq64Kbps(1), r2x64eq128Kbps(2), r3x64eq192Kbps(3), r4x64eq256Kbps(4), r5x64eq320Kbps(5), r6x64eq384Kbps(6), r7x64eq448Kbps(7), r8x64eq512Kbps(8), r9x64eq576Kbps(9), r10x64eq640Kbps(10), r11x64eq704Kbps(11), r12x64eq768Kbps(12), r13x64eq832Kbps(13), r14x64eq896Kbps(14), r15x64eq960Kbps(15), r16x64eq1024Kbps(16), r17x64eq1088Kbps(17), r18x64eq1152Kbps(18), r19x64eq1216Kbps(19), r20x64eq1280Kbps(20), r21x64eq1344Kbps(21), r22x64eq1408Kbps(22), r23x64eq1472Kbps(23), r24x64eq1536Kbps(24)  

prtInMbeLinkTo 1.3.6.1.4.1.164.3.2.3.2.11.2.1.6
It indicates the slot of the main link card to which the MBE card is mapped. In the ?004 Unit the entries io6(10)..io16) are not valid. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
Status: deprecated Access: read-write
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExTreCnfgTable 1.3.6.1.4.1.164.3.2.3.2.12.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExTreCnfgEntry

prtExTreCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.12.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtExTreCnfgEntry  

prtExTreCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.12.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtExTreSltIdx 1.3.6.1.4.1.164.3.2.3.2.12.1.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExTrePrtIdx 1.3.6.1.4.1.164.3.2.3.2.12.1.1.3
A unique port identifier within the card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1)  

prtExTreLan 1.3.6.1.4.1.164.3.2.3.2.12.1.1.4
This attribute indicates whether the TRE port is operated as main or remote bridge. Default=remote.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER remote(1), main(2)  

prtExTreLanRate 1.3.6.1.4.1.164.3.2.3.2.12.1.1.5
This attribute indicates the Rate of the TRE port in Mbit/sec. Default-r4M.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER r4M(1), r16M(2)  

prtInTreCnfgTable 1.3.6.1.4.1.164.3.2.3.2.12.2
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtInTreCnfgEntry

prtInTreCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.12.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtInTreCnfgEntry  

prtInTreCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.12.2.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtInTreSltIdx 1.3.6.1.4.1.164.3.2.3.2.12.2.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtInTrePrtIdx 1.3.6.1.4.1.164.3.2.3.2.12.2.1.3
A unique port identifier within the card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER inPrt1(101)  

prtInTreConnect 1.3.6.1.4.1.164.3.2.3.2.12.2.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtInTreRate 1.3.6.1.4.1.164.3.2.3.2.12.2.1.5
This attribute indicates the port speed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER r1x56eq56Kbps(1), r1x64eq64Kbps(2), r2x56eq112Kbps(3), r2x64eq128Kbps(4), r3x56eq168Kbps(5), r3x64eq192Kbps(6), r4x56eq224Kbps(7), r4x64eq256Kbps(8), r5x56eq280Kbps(9), r5x64eq320Kbps(10), r6x56eq336Kbps(11), r6x64eq384Kbps(12), r7x56eq392Kbps(13), r7x64eq448Kbps(14), r8x56eq448Kbps(15), r8x64eq512Kbps(16), r9x56eq504Kbps(17)  

prtInTreLinkTo 1.3.6.1.4.1.164.3.2.3.2.12.2.1.6
It indicates the slot of the main link card to which the MBE card is mapped. In the ?004 Unit the entries io6(10)..io16) are not valid. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
Status: deprecated Access: read-write
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExPVc4CnfgTable 1.3.6.1.4.1.164.3.2.3.2.9.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExPVc4CnfgEntry

prtExPVc4CnfgEntry 1.3.6.1.4.1.164.3.2.3.2.9.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtExPVc4CnfgEntry  

prtExPVc4CnfgIdx 1.3.6.1.4.1.164.3.2.3.2.9.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtExPVc4SltIdx 1.3.6.1.4.1.164.3.2.3.2.9.1.1.2
This attribute indicates a unique slot position where the card is inserted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExPVc4PrtIdx 1.3.6.1.4.1.164.3.2.3.2.9.1.1.3
This object indicates the port number in the selected card (slot).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), inPrt1(101), inPrt2(102), inPrt3(103), inPrt4(104)  

prtExPVc4PrtType 1.3.6.1.4.1.164.3.2.3.2.9.1.1.4
This object indicates the type of the selected port. In Mx 30/300: s0 is for Voice over ISDN.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER eAndM(1), fxo(2), fxs(3), internal(4), s0(5)  

prtExPVc4Connect 1.3.6.1.4.1.164.3.2.3.2.9.1.1.5
This attribute indicates whether the port should be considered in any of the mux algorithms.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExPVc4IfType 1.3.6.1.4.1.164.3.2.3.2.9.1.1.6
This attribute indicates the interface type of the port. eAndM4wires and eAndM2wires - are valid only for E&M port type eAndM4wires - means 2/4 wires fxoGnd and fxoLoop - are valid only for FXO port type fxsGnd and fxsLoop - are valid only for FXS port type e1Framer, e1Slave, t1Framer, t1Slave - are applicable for the mvc4Pbx cards only.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), eAndM4wires(2), eAndM2wires(3), fxoGnd(4), fxoLoop(5), fxsGnd(6), fxsLoop(7), e1Framer(8), e1Slave(9), t1Framer(10), t1Slave(11)  

prtExPVc4TxGain 1.3.6.1.4.1.164.3.2.3.2.9.1.1.7
Transmission gain in dBm.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

prtExPVc4RxGain 1.3.6.1.4.1.164.3.2.3.2.9.1.1.8
Reception gain in dBm.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

prtExPVc4MaxRate 1.3.6.1.4.1.164.3.2.3.2.9.1.1.9
Voice rate.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notConnected(1), r4800bps(2), r7200bps(3), r9600bps(4)  

prtExPVc4Tc 1.3.6.1.4.1.164.3.2.3.2.9.1.1.10
Time interval for CIR control, in seconds. The value will be the same for all cards' ports.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER t1sec(1), t2sec(2), t3sec(3), t4sec(4)  

prtExPVc4Oos 1.3.6.1.4.1.164.3.2.3.2.9.1.1.11
Handling type, when connection is lost.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notSupported(2), forcedIdle(3), forcedBusy(4), busyIdle(5), idleBusy(6)  

prtExPVc4EchoCanceler 1.3.6.1.4.1.164.3.2.3.2.9.1.1.12
Echo canceler activation.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtExPVc4VarDelay 1.3.6.1.4.1.164.3.2.3.2.9.1.1.13
Maximum variant delay of the FR network, in msec.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..300  

prtExPVc4CongLevel 1.3.6.1.4.1.164.3.2.3.2.9.1.1.14
This object indicates the level of delayed data in precents of total available dynamic memory, for which the port will start to operate as congested. The resolution of the parameter is 5%.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..70  

prtExPVc4Wire 1.3.6.1.4.1.164.3.2.3.2.9.1.1.15
This object indicates the wiring of the E&M port. It is applicable only for E&M card type.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER w2wire(1), w4wire(2), notApplicable(255)  

prtExPVc4ExtensionType 1.3.6.1.4.1.164.3.2.3.2.9.1.1.16
This object indicates the type of extension relevant to this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), forceConnect(2), voiceSwitching(3)  

prtExPVc4ExtensionNumber 1.3.6.1.4.1.164.3.2.3.2.9.1.1.17
This is the extension number of this port. This field is relevant only when the extension type is voice switching and is read only if the port is member of a hunt group.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(2)  

prtExPVc4OutPulsing 1.3.6.1.4.1.164.3.2.3.2.9.1.1.18
This field indicates whether to outpulse the received digits. It is notApplicable(1) when the extension type is forceConnect(2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtExPVc4HuntGroupMb 1.3.6.1.4.1.164.3.2.3.2.9.1.1.19
This object indicates if this port belongs to an hunt group.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtExPVc4HuntGroupIdx 1.3.6.1.4.1.164.3.2.3.2.9.1.1.20
If it belongs to an hunt group, this fields indicates the index of the relevant hunt group. 0 = notApplicable
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..10  

prtExPVc4AutoFaxMode 1.3.6.1.4.1.164.3.2.3.2.9.1.1.21
This object indicates if the system will switch automatically to FAX mode when detecting FAX activity. Default=Yes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtExPVc4FaxRate 1.3.6.1.4.1.164.3.2.3.2.9.1.1.22
FAX initial rate. Default=9600 bps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notConnected(1), r4800bps(2), r7200bps(3), r9600bps(4)  

prtExPVc4SeizeAck 1.3.6.1.4.1.164.3.2.3.2.9.1.1.23
This parameter shows whether the device will acknowledge a seize signal (On/Off Hook). When the value is set to yes(3) & the device receives an on/off hook signal it will transmit back an on/off hook signal. When the value is set to no(2) & the device receives an on/off hook signal it will NOT transmit back an on/off hook signal. Example: If Seize Ack Parameter = YES, when the MVC.4 receives a seize signal (Off Hook) from the PBX it will send an Off Hook to the PBX. The Seize Parameter is relevant for all the following cards: MVC-4 MVC-4/E1-Framer MVC-4/T1-DSU-Framer MVC-4/T1-CSU-Framer MVC-4/E1-SLAVE MVC-4/T1-SLAVE Default values: Analog FXS - No (value can't be changed). Analog FXO - Yes (value can't be changed). Analog E&M - No (values NO/YES). Digital E1/T1 Framer & Slave - No.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExPVc4SignalingProtocol 1.3.6.1.4.1.164.3.2.3.2.9.1.1.24
The signaling protocol that will be used between the PABX & the voice port. Delay Start Protocol: the line is seized by sending an Off hook signal and after a delay, if the called party is available (On hook) DTMF (Dual Tone Multi Frequency) digits are sent towards the called party. Immediate Start Protocol: the line is seized by sending an Off Hook signal and immediately DTMF digits are sent towards the called party. Wink start protocol: the line is seized by sending an Off Hook signal and then the called party sends a short Off Hook wink signal. Now the calling party starts sending DTMF digits.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER delayStart(2), immediateStart(3), winkStart(4)  

prtExPVc4DelayStart 1.3.6.1.4.1.164.3.2.3.2.9.1.1.25
This parameter is used only for Delay Protocol. This is the time that the calling party will wait after sending an Off hook signal and before sending DTMF digits to the called party. The delay values are 100..4000 msec in intervals of 100 msec.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

prtExPVc4WinkMinDuration 1.3.6.1.4.1.164.3.2.3.2.9.1.1.26
This parameter is used only for Wink Protocol. Min Duration of the Wink Signal (off hook duration from the called party). Legal values: 40..400 msec in intervals of 10 msec.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

prtExPVc4WinkMaxDuration 1.3.6.1.4.1.164.3.2.3.2.9.1.1.27
This parameter is used only for Wink Protocol. Max Duration of the Wink Signal (off hook duration from the called party). Legal values: 40..400 msec in intervals of 10 msec.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

prtExPVc4DlciTable 1.3.6.1.4.1.164.3.2.3.2.9.2
The write operation into the Table Objects is valid only at the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExPVc4DlciEntry

prtExPVc4DlciEntry 1.3.6.1.4.1.164.3.2.3.2.9.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtExPVc4DlciEntry  

prtExPVc4DlciCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.9.2.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtExPVc4DlciSltIdx 1.3.6.1.4.1.164.3.2.3.2.9.2.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExPVc4DlciPrtIdx 1.3.6.1.4.1.164.3.2.3.2.9.2.1.3
This attribute indicates a unique internal port number. VC4 cards have four external ports.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4)  

prtExPVc4DlciValid 1.3.6.1.4.1.164.3.2.3.2.9.2.1.4
This attribute indicates whether the attributes in this entry are valid or not. The user can add/delete pvc (dlci to dlci connection) by modifing this object
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExPVc4DlciIConSlt 1.3.6.1.4.1.164.3.2.3.2.9.2.1.5
This attribute indicates a unique slot position In the Mux (Agent) where the dlci is routed to. In the ?004 Unit the entries io6(10)..io16) are not valid
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noConnect(2), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExPVc4DlciIConPrt 1.3.6.1.4.1.164.3.2.3.2.9.2.1.6
This attribute indicates a unique port id which the dlci is routed to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), exPrt9(9), exPrt10(10), noConnect(100), inPrt1(101), inPrt2(102), inPrt3(103), inPrt4(104), inPrt5(105), inPrt6(106), inPrt7(107), inPrt8(108), inPrt9(109), inPrt10(110), inPrt11(111), inPrt12(112)  

prtExPVc4DlciIConDlci 1.3.6.1.4.1.164.3.2.3.2.9.2.1.7
This attribute indicates a unique internal connection dlci number, the dlci is routed to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..991  

prtExPVc4DlciTxBc 1.3.6.1.4.1.164.3.2.3.2.9.2.1.8
This attribute indicates a unique Tx committed bandwidth on the user transmit line (or at the port receive line).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER full(1), zero(2), txBc9600bps(3), txBc14400bps(4), txBc19200bps(5), txBc28800bps(6), txBc32000bps(7), txBc38400bps(8), txBc48000bps(9), txBc56000bps(10), txBc57600bps(11), txBc64Kbps(12), txBc128Kbps(13), txBc192Kbps(14), txBc256Kbps(15), txBc320Kbps(16), txBc384Kbps(17), txBc448Kbps(18), txBc512Kbps(19), txBc768Kbps(20), txBc1024Kbps(21), txBc16000bps(25), txBc112Kbps(26)  

prtExPVc4DlciTxBe 1.3.6.1.4.1.164.3.2.3.2.9.2.1.9
This attribute indicates a unique Tx excess bandwidth on the user transmit line (or at the port receive line).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER full(1), zero(2), txBe9600bps(3), txBe14400bps(4), txBe19200bps(5), txBe28800bps(6), txBe32000bps(7), txBe38400bps(8), txBe48000bps(9), txBe56000bps(10), txBe57600bps(11), txBe64Kbps(12), txBe128Kbps(13), txBe192Kbps(14), txBe256Kbps(15), txBe320Kbps(16), txBe384Kbps(17), txBe448Kbps(18), txBe512Kbps(19), txBe768Kbps(20), txBe1024Kbps(21), txBc16000bps(25), txBc112Kbps(26)  

prtExPVc4DlciRxBc 1.3.6.1.4.1.164.3.2.3.2.9.2.1.10
This attribute indicates a unique Rx committed bandwidth on the user receive line (or at the port transmit line).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER full(1), zero(2), rxBc9600bps(3), rxBc14400bps(4), rxBc19200bps(5), rxBc28800bps(6), rxBc32000bps(7), rxBc38400bps(8), rxBc48000bps(9), rxBc56000bps(10), rxBc57600bps(11), rxBc64Kbps(12), rxBc128Kbps(13), rxBc192Kbps(14), rxBc256Kbps(15), rxBc320Kbps(16), rxBc384Kbps(17), rxBc448Kbps(18), rxBc512Kbps(19), rxBc768Kbps(20), rxBc1024Kbps(21), rxBc16000bps(25), rxBc112Kbps(26)  

prtExPVc4DlciRxBe 1.3.6.1.4.1.164.3.2.3.2.9.2.1.11
This attribute indicates a unique Rx excess bandwidth on the user receive line (or at the port transmit line).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER full(1), zero(2), rxBe9600bps(3), rxBe14400bps(4), rxBe19200bps(5), rxBe28800bps(6), rxBe32000bps(7), rxBe38400bps(8), rxBe48000bps(9), rxBe56000bps(10), rxBe57600bps(11), rxBe64Kbps(12), rxBe128Kbps(13), rxBe192Kbps(14), rxBe256Kbps(15), rxBe320Kbps(16), rxBe384Kbps(17), rxBe448Kbps(18), rxBe512Kbps(19), rxBe768Kbps(20), rxBe1024Kbps(21), rxBc16000bps(25), rxBc112Kbps(26)  

prtExPVc4DlciPriority 1.3.6.1.4.1.164.3.2.3.2.9.2.1.12
This attribute indicates a unique priority of the pvc. 6 is the lowest priority and 8 is the highest priority.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 6..8  

prtExPVc4DlciStatus 1.3.6.1.4.1.164.3.2.3.2.9.2.1.13
This attribute indicates the status of the pvc. The status is disconnected(1) when one of the sides is programmed as not connected
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disconnected(1), connected(2)  

prtExLs6CnfgTable 1.3.6.1.4.1.164.3.2.3.2.13.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExLs6CnfgEntry

prtExLs6CnfgEntry 1.3.6.1.4.1.164.3.2.3.2.13.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtExLs6CnfgEntry  

prtExLs6CnfgIdx 1.3.6.1.4.1.164.3.2.3.2.13.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtExLs6SltIdx 1.3.6.1.4.1.164.3.2.3.2.13.1.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExLs6PrtIdx 1.3.6.1.4.1.164.3.2.3.2.13.1.1.3
This attribute indicates a unique port index.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), exPrt9(9), exPrt10(10), exPrt11(11), exPrt12(12)  

prtExLs6Connect 1.3.6.1.4.1.164.3.2.3.2.13.1.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExLs6Protocol 1.3.6.1.4.1.164.3.2.3.2.13.1.1.5
This attribute indicates the protocol. async - can be selected only for ports 1-2.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER sync(2), async(3)  

prtExLs6Rate 1.3.6.1.4.1.164.3.2.3.2.13.1.1.6
Port rates in bps. g1 - contains the values : (2)-(6),(9),(12),(16) g2 - contains the values : (7),(10),(14),(19) g3 - contains the values : (8),(11),(13),(15),(17),(18),(20); it is not applicable when using Async protocol. Rates of pair ports (1-2, 3-4, 5-6) must be from the same group.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER r300bps(2), r600bps(3), r1200bps(4), r2400bps(5), r4800bps(6), r7200bps(7), r8000bps(8), r9600bps(9), r14400bps(10), r16000bps(11), r19200bps(12), r24000bps(13), r28800bps(14), r32000bps(15), r38400bps(16), r48000bps(17), r56000bps(18), r57600bps(19), r64000bps(20)  

prtExLs6ClkMode 1.3.6.1.4.1.164.3.2.3.2.13.1.1.7
This attribute indicates a unique port operation clock mode. It is applicable for Sync protocol only .
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dce(1), extDce(2), dte1(3), notApplicable(255)  

prtExLs6CtrlSignal 1.3.6.1.4.1.164.3.2.3.2.13.1.1.8
Control Signal.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER local(2), rts(3), dtrAndRts(4)  

prtExLs6DataBits 1.3.6.1.4.1.164.3.2.3.2.13.1.1.9
Data Bits. This object is applicable for Async protocol only.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER d6bits(1), d7bits(2), d8bits(3), d9bits(4), notApplicable(255)  

prtExLs6Cts 1.3.6.1.4.1.164.3.2.3.2.13.1.1.10
This object indicates the CTS control line operation mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), on(2), rts(3)  

prtExLs6LinkToInternal 1.3.6.1.4.1.164.3.2.3.2.13.1.1.11
This object indicates which internal port of the card, the external port is linked to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER inPrt1(101), inPrt2(102), notApplicable(255)  

prtExLs6VCnfgTable 1.3.6.1.4.1.164.3.2.3.2.13.2
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExLs6VCnfgEntry

prtExLs6VCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.13.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtExLs6VCnfgEntry  

prtExLs6VCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.13.2.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtExLs6VSltIdx 1.3.6.1.4.1.164.3.2.3.2.13.2.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExLs6VPrtIdx 1.3.6.1.4.1.164.3.2.3.2.13.2.1.3
A unique identifier of the port, within the card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER exPrt7(7), exPrt8(8)  

prtExLs6VConnect 1.3.6.1.4.1.164.3.2.3.2.13.2.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExLs6VRate 1.3.6.1.4.1.164.3.2.3.2.13.2.1.5
Rate (bps) used for FAX transmission and Voice coding.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER r6400bps(2), r7200bps(3), r8000bps(4), r9600bps(5), r16000bps(6), r24000bps(7), r32000bps(8), r64000bps(9)  

prtExLs6VEchoCanceler 1.3.6.1.4.1.164.3.2.3.2.13.2.1.6
Echo canceler activation.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtExLs6VIfType 1.3.6.1.4.1.164.3.2.3.2.13.2.1.7
This attribute indicates the interface type of the port. w4wire - is applicable only for E&M port type.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER w2wire(1), w4wire(2)  

prtExLs6VTxGain 1.3.6.1.4.1.164.3.2.3.2.13.2.1.8
Transmit gain in dBm. E&M - values range: -17 .. 8 FXO - values range: -16 .. 4 FXS - values range: -13 .. 8
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

prtExLs6VRxGain 1.3.6.1.4.1.164.3.2.3.2.13.2.1.9
Receive gain in dBm. E&M - values range: -17 .. 2 FXO - values range: -17 .. -1 FXS - values range: -17 .. 2
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

prtExLs6VOos 1.3.6.1.4.1.164.3.2.3.2.13.2.1.10
Out of Service signaling mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER forcedIdle(1), forcedBusy(2), busyIdle(3), idleBusy(4)  

prtInLs6CnfgTable 1.3.6.1.4.1.164.3.2.3.2.13.3
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtInLs6CnfgEntry

prtInLs6CnfgEntry 1.3.6.1.4.1.164.3.2.3.2.13.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtInLs6CnfgEntry  

prtInLs6CnfgIdx 1.3.6.1.4.1.164.3.2.3.2.13.3.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtInLs6SltIdx 1.3.6.1.4.1.164.3.2.3.2.13.3.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtInLs6PrtIdx 1.3.6.1.4.1.164.3.2.3.2.13.3.1.3
This attribute indicates a unique internal port index.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER inPrt1(101), inPrt2(102)  

prtInLs6Connect 1.3.6.1.4.1.164.3.2.3.2.13.3.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms. It also affects all the module considerations because the module has only one Internal interface which is the composite channel.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtInLs6TandemMode 1.3.6.1.4.1.164.3.2.3.2.13.3.1.5
This object indicates the Tandem Mode. tandemSlave - is valid only for an LS-6 card having on the (current slot-1) an LS-6 card with 'tandemMaster' mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noTandem(1), tandemMaster(2), tandemSlave(3)  

prtInLs6Rate 1.3.6.1.4.1.164.3.2.3.2.13.3.1.6
Main Rate in Kbps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER r32Kbps(1), r56Kbps(2), r64Kpbs(3), r128Kbps(4), r256Kbps(5), r384Kbps(6), r192Kbps(7), r512Kbps(8), r768Kbps(9)  

prtInLs6RemoteType 1.3.6.1.4.1.164.3.2.3.2.13.3.1.7
Remote Type. notApplicable - when prtInLs6TandemMode=tandemSlave
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ls6(1), km2kSlave(2), km2kStandalone(3), notApplicable(255)  

prtInLs6LinkTo 1.3.6.1.4.1.164.3.2.3.2.13.3.1.8
It indicates the slot of the main link card to which the Ls6 card is mapped. In the ?004 Unit the entries io6(10)..io12(16) are not valid. notApplicable - when prtInLs6TandemMode=tandemSlave. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
Status: deprecated Access: read-write
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExVc3CnfgTable 1.3.6.1.4.1.164.3.2.3.2.14.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExVc3CnfgEntry

prtExVc3CnfgEntry 1.3.6.1.4.1.164.3.2.3.2.14.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtExVc3CnfgEntry  

prtExVc3CnfgIdx 1.3.6.1.4.1.164.3.2.3.2.14.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtExVc3SltIdx 1.3.6.1.4.1.164.3.2.3.2.14.1.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExVc3PrtIdx 1.3.6.1.4.1.164.3.2.3.2.14.1.1.3
A unique identifier of the port, within the card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3)  

prtExVc3Connect 1.3.6.1.4.1.164.3.2.3.2.14.1.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExVc3TransGain 1.3.6.1.4.1.164.3.2.3.2.14.1.1.5
Transmit gain in dBm.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

prtExVc3ReceiveGain 1.3.6.1.4.1.164.3.2.3.2.14.1.1.6
Receive gain in dBm.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

prtExVc3Wire 1.3.6.1.4.1.164.3.2.3.2.14.1.1.7
This object is equal for all the ports in the specific card because of HW limitations
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER w2wire(1), w4wire(2)  

prtExVc3Rate 1.3.6.1.4.1.164.3.2.3.2.14.1.1.8
Rate in bps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER r9600bps(1), r4800bps(2)  

prtExVc3EchoCanceler 1.3.6.1.4.1.164.3.2.3.2.14.1.1.9
Echo canceler activation. The value will be the same for all the card's external ports.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtInVc3CnfgTable 1.3.6.1.4.1.164.3.2.3.2.14.2
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtInVc3CnfgEntry

prtInVc3CnfgEntry 1.3.6.1.4.1.164.3.2.3.2.14.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtInVc3CnfgEntry  

prtInVc3CnfgIdx 1.3.6.1.4.1.164.3.2.3.2.14.2.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtInVc3SltIdx 1.3.6.1.4.1.164.3.2.3.2.14.2.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtInVc3PrtIdx 1.3.6.1.4.1.164.3.2.3.2.14.2.1.3
A unique identifier of the port, within the card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER inPrt1(101)  

prtInVc3Connect 1.3.6.1.4.1.164.3.2.3.2.14.2.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtInVc3Rate 1.3.6.1.4.1.164.3.2.3.2.14.2.1.5
Rate in bps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER r32000bps(1), r16000bps(2)  

prtInVc3Oos 1.3.6.1.4.1.164.3.2.3.2.14.2.1.6
This object is equal for all the ports in the specific card because of HW limitations
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER forcedIdle(1), forcedBusy(2), busyIdle(3), idleBusy(4)  

prtInVc3LinkTo 1.3.6.1.4.1.164.3.2.3.2.14.2.1.7
This attribute indicates the slot of the ML card to which the VC card is mapped. In the ?004 Unit the entries io6(10)..io12(16) are not valid. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
Status: deprecated Access: read-write
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExVcPbxCnfgTable 1.3.6.1.4.1.164.3.2.3.2.15.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExVcPbxCnfgEntry

prtExVcPbxCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.15.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtExVcPbxCnfgEntry  

prtExVcPbxCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.15.1.1.1
This object indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtExVcPbxSltIdx 1.3.6.1.4.1.164.3.2.3.2.15.1.1.2
This object indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExVcPbxPrtIdx 1.3.6.1.4.1.164.3.2.3.2.15.1.1.3
A unique identifier of the port, within the card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1)  

prtExVcPbxConnect 1.3.6.1.4.1.164.3.2.3.2.15.1.1.4
This object indicates whether the port should be considered in any of the mux algorithms.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExVcPbxGroup 1.3.6.1.4.1.164.3.2.3.2.15.1.1.5
The group object links together several VC-PBX cards, concerning compression of the same input T1/E1 link time-slots. When ports of different slots have the same group, they are linked. When ports have a different group, they are not linked. For VC-PBX/T1 and E1 cards, this object is - their own IO Slot. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExVcPbxTransparent 1.3.6.1.4.1.164.3.2.3.2.15.1.1.6
This object indicates whether the Transparent transfer of Time-Slots is required or not. Time-Slots transferred by Transparent, will not be compressed. no - applicable only for VC-PBX/T1 and VC-PBX/E1 cards yes - applicable only for VC-PBX/T1 and VC-PBX/E1 cards notApplicable - only for VC-PBX cards.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3), notApplicable(255)  

prtExVcPbxTransSignalTs 1.3.6.1.4.1.164.3.2.3.2.15.1.1.7
This object specifies the ML Time-Slot dedicated to the signaling of the PABX Transparent TSs. None = 255. When prtExVcPbxTransparent=no this object's value=None (255) When prtExVcPbxTransparent=notApplicable, this object's value=None (255). When prtExVcPbxTransparent=yes: - for VC-PBX/T1 ports, this object's valid values are 1..16 or None (255). - for VC-PBX/E1 ports, this object's value will be 16 or None (255).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

prtExVcPbxFrame 1.3.6.1.4.1.164.3.2.3.2.15.1.1.8
This object is the frame parameter for T1/E1 interface. The user should select only the parameters which are relevant to the specific card: T1 values for the VC-PBX/T1 card. E1 values for the VC-PBX/E1 card. notApplicable - for the VC-PBX card. This parameter has the same values as dsx1LineType in T1/E1 MIB (RFC-1406). The parameters in dsx1LineType are: other (1) esfT1 dsx1ESF (2) sfT1 dsx1D4 (3) g732nE1 dsx1E1 (4) g732nE1CRC dsx1E1-CRC (5) g732sE1 dsx1E1-MF (6) g732sE1CRC dsx1E1-MF-CRC (7)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER esfT1(2), sfT1(3), g732nE1(4), g732nE1CRC(5), g732sE1(6), g732sE1CRC(7), notApplicable(255)  

prtExVcPbxRestoreTime 1.3.6.1.4.1.164.3.2.3.2.15.1.1.9
The time passing from the disappearance of the loss of synchronization condition (red alarm) to the restoration of normal service. The options 1secFast(2) and 10sec62411(3) for E1 interfaces are proprietary implementation of the T1 standard to the E1 interface. ccittE1 - is applicable only for VC-PBX/E1 card notApplicable - is applicable for VC-PBX card
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER restoreT1secFast(2), restoreT10sec62411(3), ccittE1(4), notApplicable(255)  

prtExVcPbxLineCode 1.3.6.1.4.1.164.3.2.3.2.15.1.1.10
This object is the line code parameter used for T1/E1 interface. The user should select only the parameters which are relevant to the specific card: T1 line code parameters for VC-PBX/T1 E1 line code parameters for VC-PBX/E1 notApplicable - for VC-PBX This parameter has the same values as dsx1LineCoding in T1/E1 MIB (RFC-1406). The parameters in dsx1LineCoding are: dsx1JBZS (1) dsx1B8ZS (2) dsx1HDB3 (3) dsx1ZBTSI (4) dsx1AMI (5) other (6)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER b7zsT1(1), b8zsT1(2), transT1(3), hdb3E1(4), notApplicable(255)  

prtExVcPbxLineLength 1.3.6.1.4.1.164.3.2.3.2.15.1.1.11
This object is the line length parameter. It is applicable only for the VC-PBX/T1 card. notApplicable - for the VC-PBX and VC-PBX/E1 card. lenXXXpXXXft = len-XXX-XXXft.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), len0p133ft(2), len134p266ft(3), len267p399ft(4), len400p533ft(5), len534p655ft(6), notApplicable(255)  

prtExVcPbxLinkTo 1.3.6.1.4.1.164.3.2.3.2.15.1.1.12
This object indicates the slot of the ML card to which the VC-PBX/T1, VC-PBX/E1 card Transparent TSs are mapped. notApplicable - for VC-PBX card AND for VC-PBX/T1, VC-PBX/E1 cards, when prtExVcPbxTransparent=no . In the ?004 Unit the entries io6(10)..io12(16) are not valid. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
Status: deprecated Access: read-write
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExVcPbxSignalOper 1.3.6.1.4.1.164.3.2.3.2.15.1.1.13
This object indicates the Signaling Operation of the VC-PBX/T1, VC-PBX/E1 external port. notApplicable - for VC-PBX card normal - all 4 signaling bits are transferred. bEqA - copy the A bit into the B bit. Applicable only for VC-PBX/T1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), normal(2), bEqA(3), inverseA(4)  

prtExVcPbxIdleCode 1.3.6.1.4.1.164.3.2.3.2.15.1.1.14
Determines the code for transmission in empty time slots. notApplicable - for VC-PBX card .
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), hff(2), he4(3), hd5(4), h9e(5), h98(6), h7f(7), h7e(8), h54(9), h1a(10)  

prtIn1p6VcPbxCnfgTable 1.3.6.1.4.1.164.3.2.3.2.15.2
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtIn1p6VcPbxCnfgEntry

prtIn1p6VcPbxCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.15.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtIn1p6VcPbxCnfgEntry  

prtIn1p6VcPbxCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.15.2.1.1
This object indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtIn1p6VcPbxSltIdx 1.3.6.1.4.1.164.3.2.3.2.15.2.1.2
This object indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtIn1p6VcPbxPrtIdx 1.3.6.1.4.1.164.3.2.3.2.15.2.1.3
A unique identifier of the port, within the card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER inPrt1(101), inPrt2(102), inPrt3(103), inPrt4(104), inPrt5(105), inPrt6(106)  

prtIn1p6VcPbxConnect 1.3.6.1.4.1.164.3.2.3.2.15.2.1.4
This object indicates whether the port should be considered in any of the mux algorithms.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtIn1p6VcPbxRate 1.3.6.1.4.1.164.3.2.3.2.15.2.1.5
This object indicates the port Rate. For Normal mode (prtIn7p8VcPbxMode=normal), only part of the values are valid (constant rate). For Server mode (prtIn7p8VcPbxMode=server), all values are applicable (user can select the desired compression rate).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER r4800bps(1), r6400bps(2), r7200bps(3), r8000bps(4), r9600bps(5), r12800bps(6)  

prtIn1p6VcPbxEchoCanceler 1.3.6.1.4.1.164.3.2.3.2.15.2.1.6
Echo canceler activation.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtIn1p6VcPbxPabxTs 1.3.6.1.4.1.164.3.2.3.2.15.2.1.7
This object defines the PABX Time-Slot assigned to this internal port. For a T1 link, the valid values are: 1 .. 24. For an E1 link, the valid values are: 1 .. 31. This object is NOT applicable when prtIn1p6VcPbxConnect=no. This object is applicable for all cards of VC-PBX family. Default=the internal port index (1..6).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..31  

prtIn7p8VcPbxCnfgTable 1.3.6.1.4.1.164.3.2.3.2.15.3
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtIn7p8VcPbxCnfgEntry

prtIn7p8VcPbxCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.15.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtIn7p8VcPbxCnfgEntry  

prtIn7p8VcPbxCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.15.3.1.1
This object indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtIn7p8VcPbxSltIdx 1.3.6.1.4.1.164.3.2.3.2.15.3.1.2
This object indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtIn7p8VcPbxPrtIdx 1.3.6.1.4.1.164.3.2.3.2.15.3.1.3
A unique identifier of the port, within the card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER inPrt7(107), inPrt8(108)  

prtIn7p8VcPbxConnect 1.3.6.1.4.1.164.3.2.3.2.15.3.1.4
This object indicates whether the port should be considered in any of the mux algorithms.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtIn7p8VcPbxMode 1.3.6.1.4.1.164.3.2.3.2.15.3.1.5
This object indicates the working mode of the port: - normal - the compressed voice will be sent to an MTML card inside the Mux. - server - the compressed voice will be sent to the Digital Voice connector, as a service to an outside user.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), server(2)  

prtIn7p8VcPbxRate 1.3.6.1.4.1.164.3.2.3.2.15.3.1.6
This object indicates the port Main Rate. For Server mode (prtIn7p8VcPbxMode=server), the value will be notApplicable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER r32Kbps(1), r16Kbps(2), notApplicable(255)  

prtIn7p8VcPbxSignalMode 1.3.6.1.4.1.164.3.2.3.2.15.3.1.7
This object indicates the Signal Mode. For Server mode (prtIn7p8VcPbxMode=server), the only valid values are: - none - aBit
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), aBit(2), abcBit(3), abcdBit(4)  

prtIn7p8VcPbxOos 1.3.6.1.4.1.164.3.2.3.2.15.3.1.8
Out of service Signaling mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER forcedIdle(1), forcedBusy(2)  

prtIn7p8VcPbxLinkTo 1.3.6.1.4.1.164.3.2.3.2.15.3.1.9
This object indicates the slot of the ML card to which the VC card is mapped. In the ?004 Unit the entries io6(10)..io12(16) are not valid. For Server mode (prtIn7p8VcPbxMode=server), this object is not applicable. Both ports, 7 and 8 should be linked to the same Slot. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
Status: deprecated Access: read-write
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExVcPbxTsTable 1.3.6.1.4.1.164.3.2.3.2.15.4
The write operation into the table objects is valid only to the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExVcPbxTsEntry

prtExVcPbxTsEntry 1.3.6.1.4.1.164.3.2.3.2.15.4.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtExVcPbxTsEntry  

prtExVcPbxTsCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.15.4.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtExVcPbxTsSltIdx 1.3.6.1.4.1.164.3.2.3.2.15.4.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExVcPbxTsPrtIdx 1.3.6.1.4.1.164.3.2.3.2.15.4.1.3
This attribute indicates a unique port number. VCPBX/E1 and VCPBX/T1 cards have only one external interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1)  

prtExVcPbxTsIdx 1.3.6.1.4.1.164.3.2.3.2.15.4.1.4
This attribute indicates a unique PABX time slot position. The valid time slots are 1..24 for VC-PBX/T1 and 1..31 for VC-PBX/E1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtExVcPbxTsMode 1.3.6.1.4.1.164.3.2.3.2.15.4.1.5
This attribute indicates the usage, process and way of the specific PABX TS towards its destination: unused - the TS is not used (no processing, no destination). compressed - the TS is used, sent for compression to an internal port 1..6 of either the same card or a VC-PBX card of the same group. transparent - the TS is used, no processing, it is sent directly to the ML card the VC-PBX/T1,(E1) is linked to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unused(1), compressed(2), transparent(3)  

prtExVcPbxTsIConSlot 1.3.6.1.4.1.164.3.2.3.2.15.4.1.6
The object's io1..io12 values are applicable only when prtExVcPbxTsMode=compressed. Otherwise, its value should be noConnect. This object indicates whether the specified compressed time slot is connected/routed internally in the Agent and to which card it is connected. The valid selectable slots are either the current one, (prtExVcPbxTsSltIdx), or a slot containing a VC-PBX card. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noConnect(2), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExVcPbxTsIConPrt 1.3.6.1.4.1.164.3.2.3.2.15.4.1.7
This attribute indicates the internal VC-PBX port to which this PABX TS is connected for compression. noConnect - when prtExVcPbxTsIConSlot=noConnect.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noConnect(100), inPrt1(101), inPrt2(102), inPrt3(103), inPrt4(104), inPrt5(105), inPrt6(106)  

prtIsdnCnfgTable 1.3.6.1.4.1.164.3.2.3.2.16.1
The write operation into the table objects is valid only to the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtIsdnCnfgEntry

prtIsdnCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.16.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtIsdnCnfgEntry  

prtIsdnCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.16.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtIsdnSltIdx 1.3.6.1.4.1.164.3.2.3.2.16.1.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid For KM2100/4 Valid entries are 'kmxMlA ' or 'kmxMlB'
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), kmxMlA(103), kmxMlB(104), notApplicable(255)  

prtIsdnPrtIdx 1.3.6.1.4.1.164.3.2.3.2.16.1.1.3
This attribute indicates a unique port number. For MAXcess the values will be: exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), For KM-2100 the port index is calculated as follows: 100*Slot+Ch
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtIsdnConnect 1.3.6.1.4.1.164.3.2.3.2.16.1.1.4
This attribute indicates if the port is connected.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtIsdnSignalingProtocol 1.3.6.1.4.1.164.3.2.3.2.16.1.1.5
This attribute fixes which signaling protocol is used at this port (D-Channel). It is equivalent to isdnSignalingProtocol in the isdn MIB.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), etsi(3), ess5(6), dms100(7), ni1(9), ni2(10), ins64(17), ins1500(18), notApplicable(255)  

prtIsdnBasicRateLineTopology 1.3.6.1.4.1.164.3.2.3.2.16.1.1.6
This attribute is relevant for ISDN BRI only. It is equivalent to isdnBasicRateLineTopology in the isdn MIB.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER pointToPoint(1), pointToMultipoint(2), notApplicable(255)  

prtIsdnMode 1.3.6.1.4.1.164.3.2.3.2.16.1.1.7
This attribute allows the user to configure the port as leased(2) in case of connection to a TDM network.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dialup(1), leased(2), syncLeased(3), notApplicable(255)  

prtIsdnFilter 1.3.6.1.4.1.164.3.2.3.2.16.1.1.8
This attribute allows the user to configure the port: answerAll(2): accept all incoming calls, rejectAll(3): reject all incoming calls, selective(4): accept or reject according directory table.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), answerAll(2), rejectAll(3), selective(4)  

prtIsdnSimultaneousCall 1.3.6.1.4.1.164.3.2.3.2.16.1.1.9
In case of simultaneous call (local,remote and remote,local): accept(2): accept the incoming call, reject(3): reject the incoming call.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), accept(2), reject(3)  

prtIsdnNumOfAbstractTerm 1.3.6.1.4.1.164.3.2.3.2.16.1.1.10
An object for KM2100/4 agents. 255=Not Applicable When ISDN Standard = ETSI or NTT (European) the value should be 255 (NotApplicable) else If ML speed is 64Kbps value should be 1. If ML speed is 128Kbps value can be either 1 or 2 (user selection).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

prtIsdnSwitchMode 1.3.6.1.4.1.164.3.2.3.2.16.1.1.11
For KM2100. auto - The call is initiated automatically by one of the IO cards connected to KML.10(ISDN card) having ISDN Switch Mode. manual - The call is initiated by the user manually, for KML.10 having ISDN Switch Mode (via mdlSCmd). connect- The call is initiated 'immediately', for KML.10 having ISDN Switch Mode. 'immediately'- means: immediately after power-up (when product performed Reset) OR, since this value appears in the active configuration. In this case, the call can be disconnected only by power-off of the product or by changing this object to another value (or actual Remove of the KML.10 relevant card). notApplicable - For other card types.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), auto(2), manual(3), connect(4)  

prtIsdnEndpointTable 1.3.6.1.4.1.164.3.2.3.2.16.2
The write operation into the table objects is valid only to the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtIsdnEndpointEntry

prtIsdnEndpointEntry 1.3.6.1.4.1.164.3.2.3.2.16.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtIsdnEndpointEntry  

prtIsdnEndpointCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.16.2.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtIsdnEndpointSltIdx 1.3.6.1.4.1.164.3.2.3.2.16.2.1.2
This attribute indicates a unique slot position where the card is inserted. In ?004 Unit the entries io6(10)..io12(16) are not valid For KM2100/4 Valid entries are 'kmxMlA ' or 'kmxMlB'
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), kmxMlA(103), kmxMlB(104), notApplicable(255)  

prtIsdnEndpointPrtIdx 1.3.6.1.4.1.164.3.2.3.2.16.2.1.3
This attribute indicates a unique port number. For MAXcess the values will be: exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), For KM-2100 the port index is calculated as follows: 100*Slot+Ch
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtIsdnEndpointIdx 1.3.6.1.4.1.164.3.2.3.2.16.2.1.4
Since more than one endpoint may be defined per isdn entity, this field is a simple index. It corresponds to isdnEndpointIdx in the isdn MIB.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER atei1(1), atei2(2)  

prtIsdnEndpointTeiType 1.3.6.1.4.1.164.3.2.3.2.16.2.1.5
The type of TEI (Terminal Endpoint Identifier) used for this Terminal Endpoint. In case of dynamic(1), the TEI value is selected by the switch. In case of static(2), a valid TEI value has to be entered in the isdnEndpointTeiValue object. interface type as well as the Terminal Endpoint type. static(2). On Basic Rate interfaces the default value is dynamic(1) for isdn(63) Terminal Endpoints. It corresponds to isdnEndpointTeiType in the isdn MIB.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dynamic(1), static(2), notApplicable(255)  

prtIsdnEndpointTeiValue 1.3.6.1.4.1.164.3.2.3.2.16.2.1.6
When the TEI Type is static, the value of the TEI should be between 0 and 63. Else, it is not selectable by user. 255 = notApplicable. It corresponds to isdnEndpointTeiValue in the isdn MIB
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

prtIsdnEndpointSpid 1.3.6.1.4.1.164.3.2.3.2.16.2.1.7
The Service profile IDentifier (SPID) information for this Terminal Endpoint. It is is composed of 9-20 numeric characters. It corresponds to isdnEndpointSpid in the isdn MIB.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

prtIsdnEndpointBearerCh 1.3.6.1.4.1.164.3.2.3.2.16.2.1.8
This is the selected dialing channel. anyChannel - the system selects the dialing channel.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), anyChannel(2), channelB1(3), channelB2(4)  

prtIsdnEndpointRowStatus 1.3.6.1.4.1.164.3.2.3.2.16.2.1.9
This field indicates whether to consider this endpoint or not.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER active(1), destroy(6)  

prtIsdnDirectoryTable 1.3.6.1.4.1.164.3.2.3.2.16.3
The write operation into the table objects is valid only to the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtIsdnDirectoryEntry

prtIsdnDirectoryEntry 1.3.6.1.4.1.164.3.2.3.2.16.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtIsdnDirectoryEntry  

prtIsdnDirectoryCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.16.3.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtIsdnDirectorySltIdx 1.3.6.1.4.1.164.3.2.3.2.16.3.1.2
This attribute indicates a unique slot position where the card is inserted. For MX300/30 ports: io1(5) = isdn1(5) and io2(6) = isdn2(6). In ?004 Unit the entries io6(10)..io12(16) are not valid For KM2100/4 Valid entries are 'kmxMlA ' or 'kmxMlB'
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), kmxMlA(103), kmxMlB(104)  

prtIsdnDirectoryPrtIdx 1.3.6.1.4.1.164.3.2.3.2.16.3.1.3
For MAXcess this is the internal port number: 101, 102,.... For KM-2100 the port index is calculated as follows: 100*Slot+Ch
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtIsdnDirectoryLocalAddr 1.3.6.1.4.1.164.3.2.3.2.16.3.1.4
This is the local address associated with this entry. - For MX: Size=17 , Default=0 (17 characters) - For KM: Size=20, Default=blank (20 characters)
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(17..20)  

prtIsdnDirectoryLocalSubAddr 1.3.6.1.4.1.164.3.2.3.2.16.3.1.5
This is the local subaddress associated with this entry. - For MX: Size=6 , Default=0 (6 characters) - For KM: Size=4 , Default=blank (4 characters)
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(4..6)  

prtIsdnDirectoryRemoteAddr 1.3.6.1.4.1.164.3.2.3.2.16.3.1.6
This is the remote address associated with this entry. - For MX: Size=17 , Default=0 (17 characters) - For KM: Size=20, Default=blank (20 characters)
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(17..20)  

prtIsdnDirectoryRemoteSubAddr 1.3.6.1.4.1.164.3.2.3.2.16.3.1.7
This is the remote subaddress associated with this entry. - For MX: Size=6 , Default=0 (6 characters) - For KM: Size=4 , Default=blank (4 characters)
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(4..6)  

prtIsdnDirectoryPrtNu 1.3.6.1.4.1.164.3.2.3.2.16.3.1.8
This is the external port number connected to this entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

prtIsdnDirectoryTeiId 1.3.6.1.4.1.164.3.2.3.2.16.3.1.9
This is the abstract terminal id if relevant, connected to this entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

prtIsdnDirectoryRowStatus 1.3.6.1.4.1.164.3.2.3.2.16.3.1.10
This is the status for the row. It allows to know whether to consider this row or not.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER active(1), destroy(6)  

prtIsdnDirectoryLocalAddr2 1.3.6.1.4.1.164.3.2.3.2.16.3.1.11
This is the second local address associated with this entry. - For MX: Size=17 , Default=0 (17 characters) - For KM: Size=20, Default=blank (20 characters)
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(17..20)  

prtIsdnDirectoryLocalSubAddr2 1.3.6.1.4.1.164.3.2.3.2.16.3.1.12
This is the second local subaddress associated with this entry. - For MX: Size=6 , Default=0 (6 characters) - For KM: Size=4 , Default=blank (4 characters)
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(4..6)  

prtIsdnDirectoryRemoteAddr2 1.3.6.1.4.1.164.3.2.3.2.16.3.1.13
This is the second remote address associated with this entry. - For MX: Size=17 , Default=0 (17 characters) - For KM: Size=20, Default=blank(20 characters)
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(17..20)  

prtIsdnDirectoryRemoteSubAddr2 1.3.6.1.4.1.164.3.2.3.2.16.3.1.14
This is the second remote subaddress associated with this entry. - For MX: Size=6 , Default=0 (6 characters) - For KM: Size=4 , Default=blank (4 characters)
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(4..6)  

prtFrPlusCnfgTable 1.3.6.1.4.1.164.3.2.3.2.18.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtFrPlusCnfgEntry

prtFrPlusCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.18.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtFrPlusCnfgEntry  

prtFrPlusCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.18.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtFrPlusSltIdx 1.3.6.1.4.1.164.3.2.3.2.18.1.1.2
Slot Index. For ISDN BRI Ports of MX300/30, io1(5) = isdn1(5) and io2(6) = isdn2(6).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtFrPlusPrtIdx 1.3.6.1.4.1.164.3.2.3.2.18.1.1.3
This attribute indicates a unique port number. This port number should be: - for ISDN cards: inPrt1(101)->inPrt50(150) - for MHS1 card : exPrt1(1) - for MHS3, MLS3 cards: exPrt1(1)->exPrt3(3) - for MLS6 cards: exPrt1(1)->exPrt6(6).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtFrPlusNotSegmentedPriorities 1.3.6.1.4.1.164.3.2.3.2.18.1.1.4
This parameter is relevant only for FR+ protocol and asks the MXcess NOT to segment data with specified priorities: from LSB: bit 1 is for priority 1, bit 2 is for priority 2, .... till bit 7 for priority 7. - a priority selected to be segmented : its bit will be '0' - a priority not to be segmented : its bit will be '1' Default is 00000000; i.e, segment all priorities.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

prtMl4CnfgTable 1.3.6.1.4.1.164.3.2.3.2.19.1
This is an extension table for MTML-4 card parameters.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtMl4CnfgEntry

prtMl4CnfgEntry 1.3.6.1.4.1.164.3.2.3.2.19.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtMl4CnfgEntry  

prtMl4CnfgIdx 1.3.6.1.4.1.164.3.2.3.2.19.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. The write operation is valid only to the TmpCnfg.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtMl4SltIdx 1.3.6.1.4.1.164.3.2.3.2.19.1.1.2
This attribute indicates a unique slot position where the module is inserted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtMl4PrtIdx 1.3.6.1.4.1.164.3.2.3.2.19.1.1.3
This attribute indicates a unique port number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4)  

prtMl4SigProfile 1.3.6.1.4.1.164.3.2.3.2.19.1.1.4
This object indicates the Signaling Profile of the port. none - when the Frame is G732N (no MF). p1 = profile 1 p2 = profile 2 p3 = profile 3 p4 = profile 4 p5 = profile 5
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), p1(3), p2(4), p3(5), p4(6), p5(7)  

prtMl4CGA 1.3.6.1.4.1.164.3.2.3.2.19.1.1.5
This object selects the method used to signal the CGA state to the other end, through the main link. 'none' - non-transparent mode. When one of the links (main) will be in Out Of Service state, both 'Data/Voice Oos' and 'Oos' will be transmitted to the other end. 'trans' - when one of the links (main) will be in Out Of Service state, 'Data/Voice Oos' will be transmitted to the other end. 'full' - fully-transparent mode. When one of the links (main) will be in Out Of Service state, neither 'Data/Voice Oos' nor 'Oos' will be transmitted to the other end.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), trans(2), full(3)  

prtMl4Oos 1.3.6.1.4.1.164.3.2.3.2.19.1.1.6
'idle' = '0' = on-hook, idle state 'busy' = '1' = off-hook, busy state 'forcedIdle' = SP = both A and B signaling bits are forced to '0' during out-of-service periods. 'forcedBusy' = MK = both A and B signaling bits are forced to '1' during out-of-service periods. 'busyIdle' = MK_SP = A and B bits are forced to '1' for 2.5 seconds; then they are switched to '0' until out-of-service condition disappears. 'idleBusy' = SP_MK = A and B bits are forced to '0' for 2.5 seconds; then they are switched to '1' until out-of-service condition disappears. - for T1: '0'=0 ; '1'=1 - for E1: '0'=1 ; '1'=0
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notSupported(2), forcedIdle(3), forcedBusy(4), busyIdle(5), idleBusy(6)  

prtMl4VoiceOos 1.3.6.1.4.1.164.3.2.3.2.19.1.1.7
Voice Out-Of-Service code. Valid range: (0 - FF HEX). For agents that do not support this feature, the value will always be 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..4)  

prtMl4DataOos 1.3.6.1.4.1.164.3.2.3.2.19.1.1.8
Data Out-Of-Service code. Valid range: (0 - FF HEX). For agents that do not support this feature, the value will always be 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..4)  

prtMl4Service 1.3.6.1.4.1.164.3.2.3.2.19.1.1.9
Link Service. leasedLine - usual TDM interface. v51 - V5.1 interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), leasedLine(2), v51(3)  

prtAcmCnfgTable 1.3.6.1.4.1.164.3.2.3.2.20.1
This is a table for ACM port parameters.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtAcmCnfgEntry

prtAcmCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.20.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtAcmCnfgEntry  

prtAcmCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.20.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. The write operation is valid only to the TmpCnfg.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtAcmSltIdx 1.3.6.1.4.1.164.3.2.3.2.20.1.1.2
This attribute indicates a unique slot position where the module is inserted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtAcmPrtIdx 1.3.6.1.4.1.164.3.2.3.2.20.1.1.3
This attribute indicates a unique port number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), exPrt9(9), exPrt10(10), exPrt11(11), exPrt12(12)  

prtAcmConnect 1.3.6.1.4.1.164.3.2.3.2.20.1.1.4
This attribute indicates whether the port should be connected or not. Only a connected port can perform activity.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtAcmActiveState 1.3.6.1.4.1.164.3.2.3.2.20.1.1.5
This attribute indicates the Electric Active State of the port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER low(2), high(3)  

prtAcmAlrString 1.3.6.1.4.1.164.3.2.3.2.20.1.1.6
Alarm string selected by user for the Inbound ports. This object is applicable only for the Inbound Ports: ext-5..ext-12. For the Outbound Ports (ext-1..ext-4), the size of this string will be 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..35)  

alarmsTrap 1
This trap is sent whenever alarm occurs in the agent.
TRAP-TYPE    

sanityTrap 2
This trap is sent after a data base update. It returns the sanity result status and the configuration no. checked. If the result is of Flip DB Sanity Check, the configuration no. sent will be 0. If the result is of Variant Sanity Check, the configuration no. sent will be 100.
TRAP-TYPE    

cnfgFlipTrap 3
This trap is sent upon change of the active Configuration DB. Attached, is the new active Configuration no.
TRAP-TYPE    

flipDbChangeTrap 4
This trap is sent upon change of the active Flip tables (Flip DB).
TRAP-TYPE    

statusChangedTrap 5
This trap is sent upon any change of the LEDs status.
TRAP-TYPE    

agnTsTable 1.3.6.1.4.1.164.3.1.2.11.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnTsEntry

agnTsEntry 1.3.6.1.4.1.164.3.1.2.11.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AgnTsEntry  

agnTsCnfgIdx 1.3.6.1.4.1.164.3.1.2.11.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

agnTsSltIdx 1.3.6.1.4.1.164.3.1.2.11.1.1.2
This attribute indicates a unique slot position where the card is inserted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), notApplicable(255)  

agnTsPrtIdx 1.3.6.1.4.1.164.3.1.2.11.1.1.3
This attribute indicates a unique external or internal port number. For MP: exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) , exPrt7 (7) , exPrt8 (8) , exPrt9 (9) , exPrt10 (10) , exPrt11 (11) , exPrt12 (12) , inPrt1 (101) , inPrt2 (102) , inPrt3 (103) , inPrt4 (104) , inPrt5 (105) , inPrt6 (106) , inPrt7 (107) , inPrt8 (108) , inPrt9 (109) , inPrt10 (110) , inPrt11 (111) , inPrt12 (112)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnTsIdx 1.3.6.1.4.1.164.3.1.2.11.1.1.4
This attribute indicates a unique index for TS (Time-Slot). - for T1 ports - 1..24, Fbit(25) - for E1 ports - 1..31 - for HDSL ports - 1..32 ; 32 will represent TS0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..32  

agnTsBitIdx 1.3.6.1.4.1.164.3.1.2.11.1.1.5
This attribute indicates a unique index for the Bit of each TS (Time-Slot). 1..8 - Bit 1.. Bit 8 255 - notApplicable This object is applicable only in Split Time-Slot cases.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnTsConSltIdx 1.3.6.1.4.1.164.3.1.2.11.1.1.6
This attribute indicates a unique slot position In the Mux where the TS is routed to.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), notApplicable(255)  

agnTsConPrtIdx 1.3.6.1.4.1.164.3.1.2.11.1.1.7
This attribute indicates a unique port id the TS is routed to. notApplicable - when agnTsType=mng or spare For MP: exPrt1 (1) .. exPrt12 (12) , notApplicable(100), inPrt1 (101) .. inPrt48 (148).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

agnTsConIdx 1.3.6.1.4.1.164.3.1.2.11.1.1.8
This attribute indicates a unique TS number the Src TS is routed to. Valid values: - for T1 ports - 1..24, Fbit(25) - for E1 ports - 1..31 - for HDSL ports - 1..32 ; 32 will represent TS0. - notApplicable - 255 (for ports that don't have TSs).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

agnTsType 1.3.6.1.4.1.164.3.1.2.11.1.1.9
Time-Slot Type - regarding its connection and media type. voice, data, vcMP - connected and the media is specified. mng - management. This TS is Dedicated to Management (not disconnected, but not connected to another port). spare - applicable for ML-20 only. These TSs should be reserved for future connection, though at the moment are not connected.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), voice(2), data(3), vcMP(4), mng(6), spare(7)  

agnTsRowStatus 1.3.6.1.4.1.164.3.1.2.11.1.1.10
This attribute allows to create/delete a row in this table. For creating a row, the NMS should set agnTsRowStatus.255.id2.id3.id4.id5.id6.id7.id8 = active(1). For destroying a row, the NMS should set: agnTsRowStatus.255.id2.id3.id4.id5.id6.id7.id8 = destroy(6). Only rows with status active(1) are relevant.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER active(1), destroy(6)  

agnTsDirection 1.3.6.1.4.1.164.3.1.2.11.1.1.11
Direction of the connection. This parameter is especially important when in MP a ML is connected to an IO port that has no TSs, so it doesn't appear in the TS Assignment for the first 5 indexes. notApplicable - for products that do not support this object or for certain TS Types (for example: mng, spare) rx - the ML only Receives from the IO Port (the ML will appear in the first 5 indexes). tx - the ML only Transmits to the IO Port (the ML will appear in the first 5 indexes). Nothing is received back. both - the ML Receives and Transmits to the IO Port (the ML will appear in the first 5 indexes). bcastSrc - the ML is a Broadcast-Bidirectional Source. It Transmits to one or several IO Ports (including the one that appears in the last 3 indexes) and sometimes receives. The Port that responds is dynamic (it can be another each time). The ML will appear in the first 5 indexes. bcastDst - the ML is a Broadcast-Bidirectional Destination. Therefore, it Receives and sometimes Transmits. The ML will appear in the first 5 indexes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), rx(2), tx(3), both(4), bcastSrc(5), bcastDst(6)  

dacsMux 1.3.6.1.4.1.164.3.3
OBJECT IDENTIFIER    

systemDacsMux 1.3.6.1.4.1.164.3.3.1
OBJECT IDENTIFIER    

mdlDacsMux 1.3.6.1.4.1.164.3.3.2
OBJECT IDENTIFIER    

prtDacsMux 1.3.6.1.4.1.164.3.3.3
OBJECT IDENTIFIER    

genDacsMux 1.3.6.1.4.1.164.3.3.4
OBJECT IDENTIFIER    

sysSa 1.3.6.1.4.1.164.3.3.1.1
OBJECT IDENTIFIER    

sysHub 1.3.6.1.4.1.164.3.3.1.2
OBJECT IDENTIFIER    

sysStatus 1.3.6.1.4.1.164.3.3.1.3
OBJECT IDENTIFIER    

sysCurrentAlr 1.3.6.1.4.1.164.3.3.1.4
OBJECT IDENTIFIER    

sysBufferAlr 1.3.6.1.4.1.164.3.3.1.5
OBJECT IDENTIFIER    

sysConfig 1.3.6.1.4.1.164.3.3.1.6
OBJECT IDENTIFIER    

sysDbase 1.3.6.1.4.1.164.3.3.1.7
OBJECT IDENTIFIER    

sysSaSwchStatus 1.3.6.1.4.1.164.3.3.1.1.1
This object indicates the status of the switches on the SA unit. Each switch is represented by a bit. The status is a sum of 2**n, according to the bits. For SMODs products see modem's specification. For DXC product see the following: There are 4 switches: bit 0 SP-PAR (LSB) '1' - Default parameters bit 1 PSWRD '1' - Password=default '0' - Password=user selected bit 2 DB-INIT '1' - DB initiated with default '0' - DB initiated with NVRAM contents bit 3 PC-SP (MSB) '1' - Management by terminal only '0' - Management by NMS Example: If SP-PAR and PSWRD bits are set ('1'), the value will be 3 (2**1 + 2**0). When the status of the switches is unknown, the value of this object will be 255.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sysSaSwRevision 1.3.6.1.4.1.164.3.3.1.1.2
This object indicates the Software revision of the system.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

sysSaHwVersion 1.3.6.1.4.1.164.3.3.1.1.3
This object indicates the Hardware version of the system.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

sysSaPorts 1.3.6.1.4.1.164.3.3.1.1.4
This object indicates the ports that are present in the system. Each possible port is represented by a bit. The value of this object is a sum of 2**n, n=number of bits. '1' - means that the port exists '0' - means that the port does not exist For detailed bit assignment, see product's spec. Bit 0 = LSB When this object is not relevant, the value will be 0. In some cases, this object may represent ports configuration of the system AND its far-end unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sysSaReadSwch 1.3.6.1.4.1.164.3.3.1.1.5
This object indicates wether the configuration will be read from the DIP switches on the SA (stand alone) unit. Each switch is represented by a bit. If the bit is 1: the configuration will be read from the HW switch position. If the bit is 0: the configuration will be read from the SW user configuration. The DIP switches are different in each of the RAD devices. In the Tiny Router (starting from the LSB) the following switches exist: Bit 0: WAN Loop Bit 1: LAN Full Duplex (When LAN AUI connector, it is SQE) Bit 2: PPP (When WAN 4 Wire connector, it is LONG) Bit 3: IP Learn
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sysChas 1.3.6.1.4.1.164.3.3.1.2.1
OBJECT IDENTIFIER    

chassTotalNoOfSlt 1.3.6.1.4.1.164.3.3.1.2.1.1
This object indicates the number of physical slots in the Hub chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chassTotalNoOfIoSlt 1.3.6.1.4.1.164.3.3.1.2.1.2
This object indicates the total number of physical IO slots in the chassis, (not all slots must be occupied and active).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chassTotalNoOfPsSlt 1.3.6.1.4.1.164.3.3.1.2.1.3
This object indicates the number of physical Power Supply slots in the chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chassTotalNoOfClSlt 1.3.6.1.4.1.164.3.3.1.2.1.4
This object indicates the number of physical Common Logic slots in the chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chassTotalNoOfMlSlt 1.3.6.1.4.1.164.3.3.1.2.1.5
This object indicates the number of physical Main Link slots in the chassis (Kmux).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sysDcl 1.3.6.1.4.1.164.3.3.1.2.2
OBJECT IDENTIFIER    

sysDclTable 1.3.6.1.4.1.164.3.3.1.2.2.1
All the entries of this table are identical (have the same value) for all the configurations (1..255) except the TmpCnfg. The write operation into the Table Objects is valid only for the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SysDclEntry

sysDclEntry 1.3.6.1.4.1.164.3.3.1.2.2.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SysDclEntry  

sysDclCnfgIdx 1.3.6.1.4.1.164.3.3.1.2.2.1.1.1
This object indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg. This object is identical for all the configurations (1..255). Only the TmpCnf(255) might have a different value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

sysDclRedundancy 1.3.6.1.4.1.164.3.3.1.2.2.1.1.2
DCL redundancy desired state.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

sysDclActiveCl 1.3.6.1.4.1.164.3.3.1.2.2.1.1.3
Active desired DCL. When 'auto' is selected, the system automatically selects the active DCL.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), dclA(2), dclB(3)  

sysDclFlipDelay 1.3.6.1.4.1.164.3.3.1.2.2.1.1.4
If one DCL flip occured and a second one should be performed, the time from the previous flip is checked. If the time is shorter than the delay specified here (in minutes), the system should delay the flip operation until time reaches the specified delay.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER t1min(1), t2min(2), t3min(3), t4min(4)  

sysDclOnline 1.3.6.1.4.1.164.3.3.1.2.2.2
The active Dcl card of the agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER dclA(1), dclB(2)  

sysDclCopyDbTable 1.3.6.1.4.1.164.3.3.1.2.2.3
This table enables to copy a cofiguration from the Offline Dcl to the Online Dcl.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SysDclCopyDbEntry

sysDclCopyDbEntry 1.3.6.1.4.1.164.3.3.1.2.2.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SysDclCopyDbEntry  

sysDclCopyDbIdx 1.3.6.1.4.1.164.3.3.1.2.2.3.1.1
This object indicates the Idx of the Cnfg(1..255) being accessed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

sysDclCopyDbCmd 1.3.6.1.4.1.164.3.3.1.2.2.3.1.2
When this command is sent to the agent, on(3), the Database specified (Db Idx), will be copied from the Offline Dcl to the Online Dcl. Afterwards the value of this object will automatically change to off(2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

sysSDateFormat 1.3.6.1.4.1.164.3.3.1.3.1
This object indicates the date and time format used for the sysSDateAndTimeCmd and for the alarm buffer report. KM-2100 V1 and FCD-T1/E1 do not support the 'yyyyMMDD' format.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ddMMYYYY(1), mmDDYYYY(2), yyyyMMDD(4)  

sysSDateCmd 1.3.6.1.4.1.164.3.3.1.3.2
This object indicates the current date as it is known by the agent using its own real-time clock. The format would be as specified by the sysSDateFormat. This parameter can be set for time synchronization between the NMS and the Agent. * For KM-2100 V1 and FCD-T1/E1 - the string should contain '/' signs between day, month and year. Example: 12/08/1998. * For DXC and rest of the products - the string should contain '-' signs between day, month and year. Example: 12-08-1998. The day value will be in the range: 1..31. The month value will be in the range: 1..12. The year value will be in the range: 1996..2050 for products supporting the '-' format.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..255)  

sysSTimeCmd 1.3.6.1.4.1.164.3.3.1.3.3
This object indicates the current time as it is known by the agent using its own real-time clock. This parameter can be set for time synchronization between the NMS and the Agent. The string should contain ':' signs between hour, minute and second. Example: 11:05:58.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..255)  

sysSActiveCnfg 1.3.6.1.4.1.164.3.3.1.3.4
This object specifies the configuration number, that is currently active and running.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sysSEditCnfg 1.3.6.1.4.1.164.3.3.1.3.5
This object indicates the unique configuration number that is currently loaded into the tmp working space for manipulation and update operations. Value of 255 means no config. is under editing process.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sysSEditBy 1.3.6.1.4.1.164.3.3.1.3.6
This entry indicates which MMI application is working on the edited config. The editing phase starts at the first modify operation and ends after a load operation.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), snmp(2), terCon1(3), terCon2(4), terInbandCon1(5), terInbandCon2(6), lcd(7)  

sysSClkSrc 1.3.6.1.4.1.164.3.3.1.3.7
This entry indicates the source of the system clock.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER master(1), fallback(2), internal(3), ml(4)  

sysSAlrStatus 1.3.6.1.4.1.164.3.3.1.3.8
Indicates the current alarm state only for system level. This object will be set to: - major (3): when there is at least one active (ON) major alarm . - minor (4): when there is no active major alarm, but there is at least one active minor alarm. - off(2): when there is no active (ON) major or minor alarms (since last clear operation).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(2), major(3), minor(4)  

sysSAlrStatusAll 1.3.6.1.4.1.164.3.3.1.3.9
Indicates the current alarm state including all levels: system, card, port. This object will be set to: - major (3): when there is at least one active (ON) major alarm . - minor (4): when there is no active major alarm, but there is at least one active minor alarm. - off(2): when there is no active (ON) major or minor alarms (since last clear operation).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(2), major(3), minor(4)  

sysSTestStatus 1.3.6.1.4.1.164.3.3.1.3.10
Indicates the current test status (for all levels: system, card, port). This attribute will be set to: - on(3): when there is at least one test in progress on the system/card/port otherwise the value will be off(2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

sysSSanityCheckStatus 1.3.6.1.4.1.164.3.3.1.3.11
Upon completion of the Sanity Check process on the TmpCnfg this object will be set to: - fail(2): when there is at least one error (which is not just a warning) encountered otherwise, - warning(3): when there are only warnings otherwise, - ok(4). The value should be unknown(1), if the TmpCnfg was changed after the last Sanity check.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), fail(2), warning(3), ok(4)  

sysSNoOfSanityCheckErr 1.3.6.1.4.1.164.3.3.1.3.12
This object indicates the number of errors/warnings discovered by the last Sanity Check process.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sysSErrListTable 1.3.6.1.4.1.164.3.3.1.3.13
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SysSErrListEntry

sysSErrListEntry 1.3.6.1.4.1.164.3.3.1.3.13.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SysSErrListEntry  

sysSErrType 1.3.6.1.4.1.164.3.3.1.3.13.1.1
The errors are recorded in the agent, in two separate lists, according to their type: error or warning.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER error(1), warning(2)  

sysSErrIdx 1.3.6.1.4.1.164.3.3.1.3.13.1.2
Unique index number to identify an entry in the error or warning list . The maximum value cannot exceed the value of 'sysSNoOfSanityCheckErr' (actually, the sum of the Errors list max. index and the Warning list max. index should equal the value of'sysSNoOfSanityCheckErr').
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sysSErrDescription 1.3.6.1.4.1.164.3.3.1.3.13.1.3
This object is a full text description of the sanity check error including error code, IO slot and port numbers related to the code .
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

sysSMaxNoOfCnfg 1.3.6.1.4.1.164.3.3.1.3.14
Maximum number of configurations that can be defined and stored in the DACS agent. If the DACS agent has a large capacity, the maximum will be limited to 254.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sysSSelfTestResult 1.3.6.1.4.1.164.3.3.1.3.15
The test is performed by the active Common Logic card. The result will be a sum of 2**n according to the following bit convention: For DXC: bit 0 Database 1 Checksum Error (LSB) bit 1 Database 2 Checksum Error bit 2 I/O Expander Error bit 3 Counter Error bit 4 Matrix DPR Error bit 5 PS-A 5 Volt Error bit 6 PS-A 12 Volt Error bit 7 PS-B 5 Volt Error bit 8 PS-B 12 Volt Error bit 9 EPROM Failure For FCD: bit 0 I/O Expander Error (LSB) bit 1 Counter Error bit 2 EPROM Failure bit 3 Illegal Sys Config bit 4 SFIFO bit 5 EPIC Failure (ISDN) When a bit is ('1'), the error exists. When NO ERROR is encountered, this object's value will be 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sysSRelayState 1.3.6.1.4.1.164.3.3.1.3.16
Indicates the current state of the alarm relay. notApplicable - for agents that do not support this object.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3)  

sysSInvertedAlr 1.3.6.1.4.1.164.3.3.1.3.17
Indicates if there is any Inverted alarm at any level of the system (sys, card, port). notApplicable - for agents that do not support this object.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

sysSRdnFlipTable 1.3.6.1.4.1.164.3.3.1.3.18
This table includes all the Flip events due to I/O Redundancy since last Clear command of this table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SysSRdnFlipEntry

sysSRdnFlipEntry 1.3.6.1.4.1.164.3.3.1.3.18.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SysSRdnFlipEntry  

sysSRdnFlipIdx 1.3.6.1.4.1.164.3.3.1.3.18.1.1
Unique index number to identify an entry in the Redundancy Flip list.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sysSRdnFlipSlot 1.3.6.1.4.1.164.3.3.1.3.18.1.2
The slot number from which Flip was performed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), notApplicable(255)  

sysSRdnFlipPort 1.3.6.1.4.1.164.3.3.1.3.18.1.3
The port number from which Flip was performed. For DXC: For external ports the convention used will be: - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . For internal ports the convention used will be: - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . For MP: For external ports, the value will be as that of the port in the card. Example: external-3 -> 3 external-4 -> 4 For internal ports, the value will be 100 + the port in the card. Example: internal-1 -> 101 internal-4 -> 104 100=notApplicable (when Redundancy is at card level).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sysSRdnFlipCause 1.3.6.1.4.1.164.3.3.1.3.18.1.4
The last cause that caused the Flip from the Slot (Port) of sysSRdnSlot, sysSRdnPort.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sysSRdnFlipDate 1.3.6.1.4.1.164.3.3.1.3.18.1.5
Flip event Date. The format will be the one selected by user for sysSDateFormat.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sysSRdnFlipTime 1.3.6.1.4.1.164.3.3.1.3.18.1.6
Flip event Time. The format will be hh:mm:ss.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sysSRdnFlipTableClearCmd 1.3.6.1.4.1.164.3.3.1.3.19
This command, when Set to 'on', clears the Redundancy Flip table (sysSRdnFlipTable). After clear is performed, the agent will turn the value to 'off' automatically.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

sysSRdnFlipCmd 1.3.6.1.4.1.164.3.3.1.3.20
This object enables the user to send a command to the Agent, to Flip from a current Online IO card to its Redundant card. The value sent will be an Object Identifier of an entry in the sysCRdnTable. This entry defines the Redundant couple of Slots on which the Flip is applied. Setting this object, will cause the Agent to Flip from current Online card to its Redundant card. This manual flip command is applicable only for entries having Redundancy Mode=Y Cable. Agent will send the value 0 for Get.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OBJECT IDENTIFIER  

sysSAlrTable 1.3.6.1.4.1.164.3.3.1.4.1
List of system level current existing alarms .
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SysSAlrEntry

sysSAlrEntry 1.3.6.1.4.1.164.3.3.1.4.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SysSAlrEntry  

sysSAlrIdx 1.3.6.1.4.1.164.3.3.1.4.1.1.1
An index number of the current system alarms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sysSAlrCode 1.3.6.1.4.1.164.3.3.1.4.1.1.2
This object indicates a code related to a specific alarm description. The list of codes and their related descriptions will be sent to NMS request (for display purpose) by alrGenTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sysSAlrState 1.3.6.1.4.1.164.3.3.1.4.1.1.3
This object indicates the alarm state.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER minor(4), major(5)  

sysSAlarmMask 1.3.6.1.4.1.164.3.3.1.4.1.1.4
Alarm Mask is : on/off.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

sysSAlarmInvert 1.3.6.1.4.1.164.3.3.1.4.1.1.5
Alarm Invert is : on/off.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

sysSAlrClearCmd 1.3.6.1.4.1.164.3.3.1.4.2
Setting this attribute to ON, will enforce a clear operation on the system level alarms . Upon completion, the value will automatically change to off(2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

sysSAlrClearAllCmd 1.3.6.1.4.1.164.3.3.1.4.3
Setting this attribute to ON, will enforce a clear operation on all levels alarms . Upon completion, the value will automatically change to off(2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

sysSAlrMaskAll 1.3.6.1.4.1.164.3.3.1.4.4
on(3) - will cause masking of all the system level alarms. These alarms will not be sent to NMS and will not be taken into account for Alarms Status. off(2) - will unmask all system level alarms except those masked via the sysSAlrMask.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

sysSAlrMask 1.3.6.1.4.1.164.3.3.1.4.5
This object is a mask that indicates which system level alarms are masked. The masked alarms (their bit is set to '1') are neither sent to the manager, nor taken into account for alarm status and LEDs. Bit no. = Alarm code The bits that do not belong to the system level will be 0. This object is applicable only when sysSAlrMaskAll=off (otherwise all system alarms are masked). Example: When Alarms having the codes 6 and 11 are masked, the value of this object will be 840 (hex).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

sysSAlrDataUpdateCmd 1.3.6.1.4.1.164.3.3.1.4.6
on(3) - will cause Update of the Alarms Severity, Attributes and Report tables. off(2) - Upon completion, the value will automatically change to off(2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

sysBufferAlrTable 1.3.6.1.4.1.164.3.3.1.5.1
List of current existing alarms (of all levels).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SysBufferAlrEntry

sysBufferAlrEntry 1.3.6.1.4.1.164.3.3.1.5.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SysBufferAlrEntry  

sysBufferAlrIdx 1.3.6.1.4.1.164.3.3.1.5.1.1.1
An index number of the current alarms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sysBufferAlrCode 1.3.6.1.4.1.164.3.3.1.5.1.1.2
This object indicates a code related to a specific alarm description. The list of codes and thir related descriptions will be known by the NMS (for display purpose) and will appear in the unit's user manual.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sysBufferAlrState 1.3.6.1.4.1.164.3.3.1.5.1.1.3
This object indicates the alarm type. minor/major - indicates appearance of the problem and the type. event - indicates occurence of an event. off - indicates disappearance of a minor/major type alarm.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(2), minor(4), major(5)  

sysBufferAlrSlot 1.3.6.1.4.1.164.3.3.1.5.1.1.4
The slot number this alarm refers to. When the alarm refers to a system function OR the DACS agent is a stand-alone unit, the value will be 'notApplicable(255)'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER psA(1), psB(2), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), kmxPsA(101), kmxPsB(102), kmxMlA(103), kmxMlB(104), kmxCl(105), kmxOpt(106), kmxIO1(107), kmxIO2(108), kmxIO3(109), kmxIO4(110), kmxIO5(111), kmxIO6(112), kmxIO7(113), kmxIO8(114), kmxIO9(115), kmxIO10(116), kmxIO11(117), kmxIO12(118), notApplicable(255)  

sysBufferAlrPort 1.3.6.1.4.1.164.3.3.1.5.1.1.5
The port number this alarm refers to. If the port number is irrelevant to this alarm (if it is a system/card level alarm) the value will be 9999.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sysBufferAlrDate 1.3.6.1.4.1.164.3.3.1.5.1.1.6
The date when the alarm occured. The format will be according to sysSDateFormat.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

sysBufferAlrTime 1.3.6.1.4.1.164.3.3.1.5.1.1.7
The time when the alarm occured.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

sysBufferAlrClearCmd 1.3.6.1.4.1.164.3.3.1.5.2
Setting this attribute to ON, will enforce a clear operation on the Alarms Buffer. Upon completion, the value will automatically change to off(2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

sysCClkSrcTable 1.3.6.1.4.1.164.3.3.1.6.1
All the entries of this table are identical (have the same value) for all the configurations (1..255) except the TmpCnfg. The write operation into the Table Objects is valid only for the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SysCClkSrcEntry

sysCClkSrcEntry 1.3.6.1.4.1.164.3.3.1.6.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SysCClkSrcEntry  

sysCClkCnfgIdx 1.3.6.1.4.1.164.3.3.1.6.1.1.1
This attribute indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

sysCClkSrcIdx 1.3.6.1.4.1.164.3.3.1.6.1.1.2
An index in the table. There are only two entries in the table. master - refers Master clock parameters fallback - refers Fallback clock parameters
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER master(1), fallback(2)  

sysCClkSrcMode 1.3.6.1.4.1.164.3.3.1.6.1.1.3
This entry indicates the source the nodal timing is locked to. none - is an invalid option for Master clock. internal - is an invalid option for Fallback clock . station - is an invalid option for a stand-alone unit. lbt - loop-back timing notApplicable - for ML source of Kmux or ML Timing combinations when Master/Fallback clock are not applicable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), internal(2), rxClk(3), station(4), lbt(5), notApplicable(255)  

sysCClkSrcPrt 1.3.6.1.4.1.164.3.3.1.6.1.1.4
This entry is valid only when working in rxClk mode. For invalid entry the return value will be 9999. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. * The SP ports will be numbered as follows: - SP port 1 : 1 - SP port 2 : 2 For external ports the convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . For internal ports the convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . For Kmux, the port will be according to : Slot*100+Ch.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sysCClkStationFreq 1.3.6.1.4.1.164.3.3.1.6.1.1.5
This entry indicates the frequency of the station clock when the source is 'station'. The value will be applicable only when the sysCClkSrcMode is 'station'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), f1544Khz(2), f2048Khz(3)  

sysCnfgTable 1.3.6.1.4.1.164.3.3.1.6.2
All the entries of this table are identical (have the same value) for all the configurations (1..255) except the TmpCnfg. The write operation into the Table Objects is valid only for the TmpCnfg entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SysCnfgEntry

sysCnfgEntry 1.3.6.1.4.1.164.3.3.1.6.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SysCnfgEntry  

sysCnfgIdx 1.3.6.1.4.1.164.3.3.1.6.2.1.1
This attribute indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

sysCMatrixMode 1.3.6.1.4.1.164.3.3.1.6.2.1.2
Indicates the TS Matrix Mode: bidirectional - TS Assignment Matrix is symmetric. unidirectional - TS Assignment Matrix can be asymmetric. notApplicable - for agents that do not support this feature.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), bidirectional(2), unidirectional(3)  

sysCIsdnFormat 1.3.6.1.4.1.164.3.3.1.6.2.1.3
ISDN format. This parameter controls the operation mode of the ISDN ports. te - ISDN timing is derived from the signal received from the equipment it is connected to. nt - timing of the transmit path is locked to the nodal timing source. notApplicable - for agents that do not support this feature.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), te(2), nt(3)  

sysCRoutingOnEth 1.3.6.1.4.1.164.3.3.1.6.2.1.4
Mng Routing Protocol on the online CL Ethernet port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), proprietary(3), rip2(4)  

sysCRdnTable 1.3.6.1.4.1.164.3.3.1.6.3
Configuration of all Redundant I/O cards and ports. The write operation into the table objects is valid only for the TmpCnfg. A Slot/Port that have no Redundancy, will not exist in this table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SysCRdnEntry

sysCRdnEntry 1.3.6.1.4.1.164.3.3.1.6.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SysCRdnEntry  

sysCRdnCnfgIdx 1.3.6.1.4.1.164.3.3.1.6.3.1.1
This object indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sysCRdnPrimeSlot 1.3.6.1.4.1.164.3.3.1.6.3.1.2
The slot number of the Primary card of Redundancy. The Primary card should be the card that user wishes to be the online card (usually the more important one). For some Redundancy modes the importance of the redundant cards/ports is the same.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), notApplicable(255)  

sysCRdnPrimePort 1.3.6.1.4.1.164.3.3.1.6.3.1.3
The port number. For DXC: For external ports the convention used will be: - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . For internal ports the convention used will be: - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . For MP: For external ports, the value will be as that of the port in the card. Example: external-3 -> 3 external-4 -> 4 For internal ports, the value will be 100 + the port in the card. Example: internal-1 -> 101 internal-4 -> 104 100=notApplicable (when Redundancy is at card level).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sysCRdnSecSlot 1.3.6.1.4.1.164.3.3.1.6.3.1.4
The slot number of the Secondary card of Redundancy matching the Primary slot.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), notApplicable(255)  

sysCRdnSecPort 1.3.6.1.4.1.164.3.3.1.6.3.1.5
The port number. For DXC: For external ports the convention used will be: - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . For internal ports the convention used will be: - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . For MP: For external ports, the value will be as that of the port in the card. Example: external-3 -> 3 external-4 -> 4 For internal ports, the value will be 100 + the port in the card. Example: internal-1 -> 101 internal-4 -> 104 100=notApplicable (when Redundancy is at card level).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sysCRdnMode 1.3.6.1.4.1.164.3.3.1.6.3.1.6
Redundancy Mode. DXC supports: yCable(3), singleSlotProtection(6) and dualCableParallelTx(4) MP supports: dualCableAIS(2), yCable(3), dualCableParallelTx(4) and backup(5). backup - will be used when a port is backup of more than one port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dualCableAIS(2), yCable(3), dualCableParallelTx(4), backup(5), singleSlotProtection(6)  

sysCRdnRecMode 1.3.6.1.4.1.164.3.3.1.6.3.1.7
Recovery Mode. This object determines if after recovery of the failed card/port it will become on-line again or not: auto - automatic . In this case, the failed card/port will become on-line again after recovery, automatically. manual - In this case, the failed card/port will not become on-line again after recovery.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER auto(2), manual(3)  

sysCRdnRecTime 1.3.6.1.4.1.164.3.3.1.6.3.1.8
Redundancy Recovery Time (sec). After switching to the current online card, the next switch can be performed only after a minimum time, indicated by this object. This object is applicable only when sysCRdnRecMode=auto.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..99  

sysCRdnHwSwFlip 1.3.6.1.4.1.164.3.3.1.6.3.1.9
HW or SW decision for Redundancy Flip. This object is applicable only for sysCRdnMode=singleSlotProtection. HW - decision is by I/O card SW - decision is by CL SW.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), hw(2), sw(3)  

sysCRdnRowStatus 1.3.6.1.4.1.164.3.3.1.6.3.1.10
This parameter allows NMS to create/delete entries of this table.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER active(1), destroy(6)  

sysCRdnOnline 1.3.6.1.4.1.164.3.3.1.6.3.1.11
Status - who is the Online (current) Redundancy Slot/Port. This object shows only the Online Slot/Port regarding the Redundancy. mdlSActivity or prtGenActiveStatus of the same Slot/Port may be Offline.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), primary(2), secondary(3)  

sysDbaseSanityCheckCmd 1.3.6.1.4.1.164.3.3.1.7.1
Setting this attribute to on(3) will initiate the process of Sanity check on the TmpCnfg. Upon completion, the value will automatically change to off(2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

sysDbaseDownloadCnfgIdxCmd 1.3.6.1.4.1.164.3.3.1.7.2
This attribute specifies the Id of the target RealCnfg to which the TmpCnfg should be transferred. Upon set command, the DACS agent will initiate the Sanity-Check process. If successful, the actual transfer will be performed. If there will be errors, the user will have to perform the command again after errors correction. The operation is valid only on configuration numbers that do not exceed sysSMaxNoOfCnfg.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

sysDbaseUploadCnfgIdxCmd 1.3.6.1.4.1.164.3.3.1.7.3
This attribute specifies the Id of the source Cnfg to be loaded into the TmpCnfg. Upon set operation the actual transfer will be initiated. The operation is valid only on configuration numbers that do not exceed sysSMaxNoOfCnfg.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

sysDbaseFlipTable 1.3.6.1.4.1.164.3.3.1.7.4
Dbase Flip time and activation for every configuration.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SysDbaseFlipEntry

sysDbaseFlipEntry 1.3.6.1.4.1.164.3.3.1.7.4.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SysDbaseFlipEntry  

sysDbaseFlipIdx 1.3.6.1.4.1.164.3.3.1.7.4.1.1
This attribute indicates the Idx of the Cnfg being the target Configuration.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

sysDbaseFlipTime 1.3.6.1.4.1.164.3.3.1.7.4.1.2
This attribute indicates the time (HH:MM) when this data base will start being used by the Tmp config.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..255)  

sysDbaseFlipActivation 1.3.6.1.4.1.164.3.3.1.7.4.1.3
This attribute indicates if the Dbase flip will be activated at the time specified for this configuration (enable) or not (disable). No more than one flip should be enabled for the same time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

mdlGen 1.3.6.1.4.1.164.3.3.2.1
OBJECT IDENTIFIER    

mdlCl 1.3.6.1.4.1.164.3.3.2.2
OBJECT IDENTIFIER    

mdlPs 1.3.6.1.4.1.164.3.3.2.3
OBJECT IDENTIFIER    

mdlSTable 1.3.6.1.4.1.164.3.3.2.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MdlSEntry

mdlSEntry 1.3.6.1.4.1.164.3.3.2.1.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MdlSEntry  

mdlSSltIdx 1.3.6.1.4.1.164.3.3.2.1.1.1.1
A unique number to identify a slot position in the DACS. The Kilomux should use enumerated values starting with kmx.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER psA(1), psB(2), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), kmxPsA(101), kmxPsB(102), kmxMlA(103), kmxMlB(104), kmxCl(105), kmxOpt(106), kmxIO1(107), kmxIO2(108), kmxIO3(109), kmxIO4(110), kmxIO5(111), kmxIO6(112), kmxIO7(113), kmxIO8(114), kmxIO9(115), kmxIO10(116), kmxIO11(117), kmxIO12(118)  

mdlSCardType 1.3.6.1.4.1.164.3.3.2.1.1.1.2
This attribute indicates the type of the card installed in the specific slot position. Only PS's are possible in the PS slots. Only CL's are possible in the CL slots. Only IO modules are possible in the IO slots. Kmux card type start with the letter k.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), empty(2), psAC(10), psDC(11), dCl(20), kCl(21), dcl2(22), dcl2Eth(23), kClEth(24), dT1DSU(30), dT1CSU(31), dE1DSU(32), dE1LTU(33), dE1aDSU(34), dE1aLTU(35), dT1F(36), dE1F(37), dE1Hdsl(40), dT1Hdsl(41), dE1HdslS(42), dT1HdslS(43), kML1(50), kML2(51), kML3(52), kML4(53), kML5(54), kML6(55), kML7(56), kML8(57), kML10(59), kMLF(60), kML10New(61), kLS1(70), kLS1New(71), kLS2(72), kTRE(80), kMBE(81), kMBENew(82), kai(90), kdi(91), kdiCH(92), dHS2(100), kHS1(110), kHS2(111), kHSU1(112), kHSU2(113), kHS703(114), kVC1EM(130), kVC1FXO(131), kVC1FXS(132), kVC1MEM(133), kVC1MFXO(134), kVC1MFXS(135), kVC1MFXSW(136), kVC2EM(137), kVC2FXO(138), kVC2FXS(139), kVC2s1EM(140), kVC2s1FXO(141), kVC2s1FXS(142), kVC3EM(143), kVC3FXO(144), kVC3FXS(145), kVC3S0(146), kVF1EM(170), kVF1FXO(171), kVF1FXS(172), kVF3EM(173), kVF3FXO(174), kVF3FXS(175), kVF4EM(176), kVF4FXO(177), kVF4FXS(178), kVF4FXSW(179), kVF4S0(180), kVF5PbxE1(181), kVF5E1PbxSlave(182), kVF5PbxT1(183), kVF5T1PbxSlave(184), kVF5PbxE1New(185), kVF5E1PbxSlaveNew(186), kVF5PbxT1New(187), kVF5T1PbxSlaveNew(188), kVF4FXO3(189), kVF4FXS3(190), kVF4NS0(191), kVF6E1s16(192), kVF6E1s31(193), kVF6T1s12(194), kVF6T1s24(195), kVF8EM(196), kVF8FXO(197), kVF8FXS(198), dimV35(201), dimRS422(202), dimRS530(203), dimHssi(204), dimX21(205), dim10BaseT(206), dimE1(207), dt3(210), dt3f(211), de3(212), de3f(213)  

mdlSHwVer 1.3.6.1.4.1.164.3.3.2.1.1.1.3
This attribute indicates the Hardware version of the card installed in the specific slot position.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

mdlSSwVer 1.3.6.1.4.1.164.3.3.2.1.1.1.4
This attribute indicates the Software version of the card installed in the specific slot position.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

mdlSAlarmStatus 1.3.6.1.4.1.164.3.3.2.1.1.1.5
Indicates the current alarm state only for card level. This object will be set to: - major (3): when there is at least one active (ON) major alarm . - minor (4): when there is no active major alarm, but there is at least one active minor alarm. - off(2): when there is no active (ON) major or minor alarms (since last clear operation).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(2), major(3), minor(4)  

mdlSAlarmStatusAll 1.3.6.1.4.1.164.3.3.2.1.1.1.6
Indicates the current card alarm state including the lower level: card, port. This object will be set to: - major (3): when there is at least one active (ON) major alarm . - minor (4): when there is no active major alarm, but there is at least one active minor alarm. - off(2): when there is no active (ON) major or minor alarms (since last clear operation).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(2), major(3), minor(4)  

mdlSTestStatus 1.3.6.1.4.1.164.3.3.2.1.1.1.7
This attribute will be on(3) when there is at least one test running on a port of the module; otherwise the value will be off(2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlSHwStatus 1.3.6.1.4.1.164.3.3.2.1.1.1.8
This attribute will be fail(2) when a HW FAIL exists on this module (discovered by periodic self test); otherwise the value will be ok(3).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER fail(2), ok(3)  

mdlSActivity 1.3.6.1.4.1.164.3.3.2.1.1.1.9
notApplicable - when the slot is empty (no module) offline(1) - when the module is not active (redundant) online (2) - when the module is active .
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), offline(2), online(3)  

mdlSAlrClearCmd 1.3.6.1.4.1.164.3.3.2.1.1.1.10
Setting this attribute to ON, will enforce a clear operation on the card level alarms . Upon completion, the value will automatically change to off(2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlSAlrClearAllCmd 1.3.6.1.4.1.164.3.3.2.1.1.1.11
Setting this attribute to ON, will enforce a clear operation on card and port level alarms . Upon completion, the value will automatically change to off(2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlSAlrMaskAll 1.3.6.1.4.1.164.3.3.2.1.1.1.12
on(3) - will cause masking of all the card level alarms. These alarms will not be sent to NMS and will not be taken into account for Alarms Status. off(2) - will unmask all card level alarms except those masked via the mdlAlrMaskTable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlSCmd 1.3.6.1.4.1.164.3.3.2.1.1.1.13
General object for any special command at card level. 0=NotApplicable, for cards that don't support this object. For KML.10(ISDN) card of KM-2100, the object will indicate Manual Call Command in Switch mode. It is applicable only when for KML.10, prtIsdnSwitchMode=manual. KML.10 valid values: '1' = noOp, will be used by agents that does not support this feature or object '2' = off, Set call command mode to disconnect state. Disconnects the call. '3' = on, Set call command mode to connect state. Connects the call.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mdlCTable 1.3.6.1.4.1.164.3.3.2.1.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MdlCEntry

mdlCEntry 1.3.6.1.4.1.164.3.3.2.1.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MdlCEntry  

mdlCConfigIdx 1.3.6.1.4.1.164.3.3.2.1.2.1.1
This object indicates the Configuration number (1..255) referred. Value of 255 specifies the TmpCnfg (Scratch).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

mdlCSlotIdx 1.3.6.1.4.1.164.3.3.2.1.2.1.2
This object indicates a unique number of the slot position in which the module is inserted. The Kilomux should use enumerated values starting with kmx.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER psA(1), psB(2), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), kmxPsA(101), kmxPsB(102), kmxMlA(103), kmxMlB(104), kmxCl(105), kmxOpt(106), kmxIO1(107), kmxIO2(108), kmxIO3(109), kmxIO4(110), kmxIO5(111), kmxIO6(112), kmxIO7(113), kmxIO8(114), kmxIO9(115), kmxIO10(116), kmxIO11(117), kmxIO12(118)  

mdlCProgCardType 1.3.6.1.4.1.164.3.3.2.1.2.1.3
This object indicates the card type assigned to the specific slot in the common configuration. This object is identical for all the configurations (1..255). Only the TmpCnf(255) might have a different value. The write operation is valid only for the TmpCnfg entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), empty(2), psAC(10), psDC(11), dCl(20), kCl(21), dcl2(22), dcl2Eth(23), kClEth(24), dT1DSU(30), dT1CSU(31), dE1DSU(32), dE1LTU(33), dE1aDSU(34), dE1aLTU(35), dT1F(36), dE1F(37), dE1Hdsl(40), dT1Hdsl(41), dE1HdslS(42), dT1HdslS(43), kML1(50), kML2(51), kML3(52), kML4(53), kML5(54), kML6(55), kML7(56), kML8(57), kML10(59), kMLF(60), kML10New(61), kLS1(70), kLS1New(71), kLS2(72), kTRE(80), kMBE(81), kMBENew(82), kai(90), kdi(91), kdiCH(92), dHS2(100), kHS1(110), kHS2(111), kHSU1(112), kHSU2(113), kHS703(114), kVC1EM(130), kVC1FXO(131), kVC1FXS(132), kVC1MEM(133), kVC1MFXO(134), kVC1MFXS(135), kVC1MFXSW(136), kVC2EM(137), kVC2FXO(138), kVC2FXS(139), kVC2s1EM(140), kVC2s1FXO(141), kVC2s1FXS(142), kVC3EM(143), kVC3FXO(144), kVC3FXS(145), kVC3S0(146), kVF1EM(170), kVF1FXO(171), kVF1FXS(172), kVF3EM(173), kVF3FXO(174), kVF3FXS(175), kVF4EM(176), kVF4FXO(177), kVF4FXS(178), kVF4FXSW(179), kVF4S0(180), kVF5PbxE1(181), kVF5E1PbxSlave(182), kVF5PbxT1(183), kVF5T1PbxSlave(184), kVF5PbxE1New(185), kVF5E1PbxSlaveNew(186), kVF5PbxT1New(187), kVF5T1PbxSlaveNew(188), kVF4FXO3(189), kVF4FXS3(190), kVF4NS0(191), kVF6E1s16(192), kVF6E1s31(193), kVF6T1s12(194), kVF6T1s24(195), kVF8EM(196), kVF8FXO(197), kVF8FXS(198), dimV35(201), dimRS422(202), dimRS530(203), dimHssi(204), dimX21(205), dim10BaseT(206), dimE1(207), dt3(210), dt3f(211), de3(212), de3f(213)  

mdlCNoOfExtPrt 1.3.6.1.4.1.164.3.3.2.1.2.1.4
Number of external ports in the programmed module of the specific slot position
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mdlCNoOfIntPrt 1.3.6.1.4.1.164.3.3.2.1.2.1.5
Number of internal ports in the programmed module of the specific slot position.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mdlAlr 1.3.6.1.4.1.164.3.3.2.1.3
OBJECT IDENTIFIER    

mdlAlrTable 1.3.6.1.4.1.164.3.3.2.1.3.1
The list of card alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MdlAlrEntry

mdlAlrEntry 1.3.6.1.4.1.164.3.3.2.1.3.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MdlAlrEntry  

mdlAlrIdx 1.3.6.1.4.1.164.3.3.2.1.3.1.1.1
A unique number to identify an entry in the alarm status table. Users should use the get next function to read this table because the indexes are not consecutive
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mdlAlrSltIdx 1.3.6.1.4.1.164.3.3.2.1.3.1.1.2
This attribute indicates the desired slot position. The Kilomux should use enumerated values starting with kmx.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER psA(1), psB(2), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), kmxPsA(101), kmxPsB(102), kmxMlA(103), kmxMlB(104), kmxCl(105), kmxOpt(106), kmxIO1(107), kmxIO2(108), kmxIO3(109), kmxIO4(110), kmxIO5(111), kmxIO6(112), kmxIO7(113), kmxIO8(114), kmxIO9(115), kmxIO10(116), kmxIO11(117), kmxIO12(118)  

mdlAlrCode 1.3.6.1.4.1.164.3.3.2.1.3.1.1.3
This object indicates a code related to a specific alarm description. The list of codes and their related descriptions will be sent to NMS request (for display purpose) by alrGenTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mdlAlrState 1.3.6.1.4.1.164.3.3.2.1.3.1.1.4
This object indicates the card alarm state.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER minor(4), major(5)  

mdlAlarmMask 1.3.6.1.4.1.164.3.3.2.1.3.1.1.5
Alarm Mask is : on/off.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlAlarmInvert 1.3.6.1.4.1.164.3.3.2.1.3.1.1.6
Alarm Invert is : on/off.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlAlrMaskTable 1.3.6.1.4.1.164.3.3.2.1.3.2
The list of card masked alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MdlAlrMaskEntry

mdlAlrMaskEntry 1.3.6.1.4.1.164.3.3.2.1.3.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MdlAlrMaskEntry  

mdlAlrMaskSltIdx 1.3.6.1.4.1.164.3.3.2.1.3.2.1.1
This attribute indicates the desired slot position. The Kilomux should use enumerated values starting with kmx.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER psA(1), psB(2), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), kmxPsA(101), kmxPsB(102), kmxMlA(103), kmxMlB(104), kmxCl(105), kmxOpt(106), kmxIO1(107), kmxIO2(108), kmxIO3(109), kmxIO4(110), kmxIO5(111), kmxIO6(112), kmxIO7(113), kmxIO8(114), kmxIO9(115), kmxIO10(116), kmxIO11(117), kmxIO12(118)  

mdlAlrMask 1.3.6.1.4.1.164.3.3.2.1.3.2.1.2
This object is a mask that indicates which card level alarms are masked. The masked alarms (their bit is set to '1') are neither sent to the manager, nor taken into account for alarm status and LEDs. Bit no. = Alarm code The bits that do not belong to the card level will be 0. This object is applicable only when mdlSAlrMaskAll=off (otherwise all card alarms are masked). Example: When Alarm having the code 8 is masked, the value of this object will be 100 (hex).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8..10)  

mdlClTable 1.3.6.1.4.1.164.3.3.2.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MdlClEntry

mdlClEntry 1.3.6.1.4.1.164.3.3.2.2.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MdlClEntry  

mdlClIdx 1.3.6.1.4.1.164.3.3.2.2.1.1.1
This object indicates the Cl slot referred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER clA(3), clB(4)  

mdlClSwchStatus 1.3.6.1.4.1.164.3.3.2.2.1.1.2
This object indicates the status of the switches on the referred DCL card. Each switch is represented by a bit. The status is a sum of 2**n, according to the bits. There are 4 switches: bit 0 SP-PAR (LSB) '1' - Default parameters bit 1 PSWRD '1' - Password=default '0' - Password=user selected bit 2 DB-INIT '1' - DB initiated with default '0' - DB initiated with NVRAM contents bit 3 PC-SP (MSB) '1' - Management by terminal only '0' - Management by NMS Example: If SP-PAR and PSWRD bits are set ('1'), the value will be 3 (2**1 + 2**0). When the status of the switches is unknown, the value of this object will be 255.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mdlClLastFlipDate 1.3.6.1.4.1.164.3.3.2.2.1.1.3
Date when last flip occured. The format would be as specified by the sysSDateFormat.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

mdlClLastFlipTime 1.3.6.1.4.1.164.3.3.2.2.1.1.4
Time when last flip occured.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

mdlClLastFlipCause 1.3.6.1.4.1.164.3.3.2.2.1.1.5
The cause of last flip.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

mdlPsTable 1.3.6.1.4.1.164.3.3.2.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MdlPsEntry

mdlPsEntry 1.3.6.1.4.1.164.3.3.2.3.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MdlPsEntry  

mdlPsIdx 1.3.6.1.4.1.164.3.3.2.3.1.1.1
This object indicates the PS card referred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER psA(1), psB(2)  

mdlPsStatus 1.3.6.1.4.1.164.3.3.2.3.1.1.2
This object indicates the status of the PS card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notActive(1), active(2)  

mdlPsTestResult 1.3.6.1.4.1.164.3.3.2.3.1.1.3
This object indicates the result of the PS card test. ok (1) - the test passed successfully. f12V (2) - 12V FAIL was detected f5V (3) - 5V FAIL was detected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), f12V(2), f5V(3)  

prtGen 1.3.6.1.4.1.164.3.3.3.1
OBJECT IDENTIFIER    

prtT1E1 1.3.6.1.4.1.164.3.3.3.2
OBJECT IDENTIFIER    

prtHS 1.3.6.1.4.1.164.3.3.3.3
OBJECT IDENTIFIER    

prtSP 1.3.6.1.4.1.164.3.3.3.4
OBJECT IDENTIFIER    

prtDim 1.3.6.1.4.1.164.3.3.3.5
OBJECT IDENTIFIER    

prtI 1.3.6.1.4.1.164.3.3.3.6
OBJECT IDENTIFIER    

prtHdsl 1.3.6.1.4.1.164.3.3.3.7
OBJECT IDENTIFIER    

prtT3E3 1.3.6.1.4.1.164.3.3.3.8
OBJECT IDENTIFIER    

prtGenParamTable 1.3.6.1.4.1.164.3.3.3.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtGenEntry

prtGenEntry 1.3.6.1.4.1.164.3.3.3.1.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtGenEntry  

prtGenPrtIdx 1.3.6.1.4.1.164.3.3.3.1.1.1.1
This attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside/external, inside/internal. In the Kilomux, the port index is calculated as follows: 100*Slot+Ch. The external Ch numbers are 1..10, and the internal Ch numbers are 11..20. In the DXC : - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 .
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtGenSlt 1.3.6.1.4.1.164.3.3.3.1.1.1.2
This attribute indicates a unique number to identify the slot where the card is inserted in. When the unit is stand-alone, this object is not applicable and 255 will be used. The Kilomux should use the enumerated starting with kmx.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), kmxMlA(103), kmxMlB(104), kmxCl(105), kmxOpt(106), kmxIO1(107), kmxIO2(108), kmxIO3(109), kmxIO4(110), kmxIO5(111), kmxIO6(112), kmxIO7(113), kmxIO8(114), kmxIO9(115), kmxIO10(116), kmxIO11(117), kmxIO12(118), standAlone(255)  

prtGenExtInt 1.3.6.1.4.1.164.3.3.3.1.1.1.3
This attribute describes the type of the designated port. Exteral port is a port with a physical connector. Internal port might be of two types, one is a composite port which collects data of a few external ports into a common bandwidth (usually routed trough DS1 link); the other type is internal ports which get only part of external port data (usually a few DS0's). In the Kilomux-2100, the internal(3) value is used for composite channels or sub-channels of an ISDN Ch.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER external(2), internal(3)  

prtGenIfIndex 1.3.6.1.4.1.164.3.3.3.1.1.1.4
This attribute indicates the unique interface number assigned to the port. The specific interface of this attribute is the same as the interface identified by the value of ifindex in MIB-II.If there is no interface for the specific prtIdx, the value will be '7fffffff'h.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtGenActiveStatus 1.3.6.1.4.1.164.3.3.3.1.1.1.5
This attribute describes the activity status of the port. unknown(1) indicates that the information is not supported. notUsed(2) indicates that the port is not connected according to the active config. offLine(3) indicates that the port is down (not working) due to any problem. onLine (4) indicates that the port is up (working) offLineRedundancy(5) indicates that the port is down because it is a redundant port. onLineRedundancy (6) indicates that this is a redundant port which is up and works as the active link.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), notUsed(2), offLine(3), onLine(4), offLineRedundancy(5), onLineRedundancy(6)  

prtGenAlrStatus 1.3.6.1.4.1.164.3.3.3.1.1.1.6
Indicates the alarm state at port (ch) agent level. This object will be set to: - major (3): when there is at least one active (ON) major alarm . - minor (4): when there is no active major alarm, but there is at least one active minor alarm. - off(2): when there is no active (ON) major or minor alarms (since last clear operation).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(2), major(3), minor(4)  

prtGenTestStatus 1.3.6.1.4.1.164.3.3.3.1.1.1.7
This attribute will be on(3) when there is at least one test in progress (running) on the port; otherwise the value will be off(2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtGenTestMask 1.3.6.1.4.1.164.3.3.3.1.1.1.8
This is a mask which indicates which tests from the 'prtGenTestCmd' list are allowed for the selected port. If a specific test is allowed, its respective bit will be SET in the mask : TEST BIT ----------- --- localLoop 1 remoteLoop 2 bert 3 plb 4 inband 5 prbs 8 loop2-v54 (RLB) 9 loop3-v54 (LLB) 10 Tone injection 13 Tx-plb 14 Tx-llb 15 DTE loop (HSSI) 16 HDSL-Tx-Inband 20 HDSL-Rx-Inband 21 Monitor 22 (test port) User Line Loopback 23 e.g : If the return value is 3 -> 0000000000000011 -> Bits 1 & 2 are set -> the allowed tests are : local-loop remote-loop
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtGenTestCmd 1.3.6.1.4.1.164.3.3.3.1.1.1.9
Setting this object to a value as detailed furter on (except 0) will initiate a test on the specific port, if the operation is allowed (according to TestMask). If the operation is not allowed, the mux will ignore the operation. The test/s requested will be set according to the respective bit: TEST BIT ----------- --- localLoop 1 remoteLoop 2 bert 3 plb 4 inband 5 prbs 8 loop2-v54 (RLB) 9 loop3-v54 (LLB) 10 Tone injection 13 Tx-plb 14 Tx-llb 15 DTE loop (HSSI) 16 HDSL-Tx-Inband 20 HDSL-Rx-Inband 21 Monitor 22 (test port) User Line Loopback 23 e.g : If the requested value is 3 -> 0000000000000011 -> Bits 1 & 2 are set -> the requested tests are : local-loop remote-loop Setting this object to stop (value=0 ; all bits are 0), will stop all the user requested tests running on the selected port; it will NOT stop the tests initiated by the system.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

prtGenTestRunning 1.3.6.1.4.1.164.3.3.3.1.1.1.10
This object indicates which tests are running currently on the selected port (initiated by user and/or by the system). If a specific test is currently running on the port, its respective bit will be SET: TEST BIT ----------- --- localLoop 1 remoteLoop 2 bert 3 plb 4 llb 5 txInband 6 rxInband 7 prbs 8 loop2-v54 (RLB) 9 loop3-v54 (LLB) 10 DDS DSU loop 11 DDS CSU loop 12 Tone injection 13 Tx-plb 14 Tx-llb 15 DTE loop (HSSI) 16 Local DTE loop (HSSI)17 Local Line loop (HSSI)18 Remote Line loop (HSSI)19 HDSL-Tx-Inband 20 HDSL-Rx-Inband 21 Monitor 22 (test port) User Line Loopback 23 Network Line Loopback 24 e.g : If the return value is 3 -> 0000000000000011 -> Bits 1 & 2 are set -> the running tests are : local-loop remote-loop llb (Bit 5) - can be initiated by system only!
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtGenType 1.3.6.1.4.1.164.3.3.3.1.1.1.11
This object describes the type of the selected port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), t1(2), e1(3), hs(4), t1Csu(5), t1Dsu(6), e1Ltu(7), e1Dsu(8), hdsl(9), sp(10), t1F(11), e1F(12), dim(13), isdn(14), t3(15), e3(16), t3f(17), e3f(18), other(255)  

prtGenInterfaceType 1.3.6.1.4.1.164.3.3.3.1.1.1.12
This attribute indicates a unique HW interface type of the selected port. Examples: - for T1 cards: DSU, CSU - for E1 cards: DSU, LTU - for HS cards: v35, rs422, x21 etc...
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

prtGenAlrClearCmd 1.3.6.1.4.1.164.3.3.3.1.1.1.13
Setting this attribute to ON, will enforce a clear operation on the port level alarms . Upon completion, the value will automatically change to off(2). noOp - will be used by agents that do not support this feature or object.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noOp(1), off(2), on(3)  

prtGenAlrMaskAll 1.3.6.1.4.1.164.3.3.3.1.1.1.14
on(3) - will mask all the alarms of the selected port off(2)- will unmask all alarms of the selected port except the ones selected by the prtAlrMaskTable. noOp - will be used by agents that do not support this feature or object.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noOp(1), off(2), on(3)  

prtGenParamStatus 1.3.6.1.4.1.164.3.3.3.1.1.1.15
This object indicates Status of parameters specific to the selected port. - For a port that has no special status or is supported by prtSExHsfStatTable - 1 Octet: 00hex - For HS cards - 1 octet: Bit 7 (MSB)..Bit 2 = 0 (NA) Bit 0 and 1 indicates RTS control signal state: Bit 1: '1'=active ; '0'=notActive Bit 0 (LSB): '1'=unknown ; '0'=NA - For VC-6, VC-12, VC-12/6 external ports - 1 Octet : Bit 7 (MSB)..Bit 2 = 0 (NA) Bit 1: Tx Signaling '1'=On ; '0'=Off Bit 0 (LSB): Rx Signaling '1'=On ; '0'=Off - For VC-2/R2(FXS) external ports - 1 Octet : Bit - 7 6 5 4 3 2 1 0 |_| |_________| Call Call State Direction Bit 7 (MSB) and Bit 6 : Call Direction 00 - Incoming 01 - Outgoing Bit 5..Bit 0: Call State 000000 - Idle 000001 - Seized 000010 - Both-Way Conflict 000011 - Seizure Ack 000100 - Answered 000101 - Clear Backward 000110 - Clear Forward 000111 - Blocked 001000 - Fault 001001 - Fault 3 001010 - Fault 4 001011 - Fault 5 001100 - Fault 6 001101 - Fault 7 - For ML-20 external port - 3 Octets : - 1 MS Octet will represent the Real Rate used: Bit - 7 6 5 4 3 2 1 0 |___| |_______| spare Rate Valid values: 0..31, meaning 0..31x64Kbps Invalid values: 32..255. - 2 LS Octets will represent the Status of 7 Control Signals: Signal - --- CTS DSR DCD RJ TM DTR RTS Bit - 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Octet - 2 3 (LS) '---' will always have the value 00 Rest of the Signals (2 bits each) can have the following values: 00=NA ; 01=Unused ; 10=Off ; 11=On - For ML-H/E1, ML-H/1/E1, ML-H/S/E1 internal port - 1 Octet Bit - 7 6 5 4 3 2 1 0 |___________| spare Mode of Operation Mode of Operation: '1'=Central ; '0'=Remote - For KM2100, KVF.5 cards - indicates the status of A and B signaling for each internal channel. 1 Octet: Bit - 7 6 5 4 3 2 1 0 |_____| |_| |_| spare B A Bit 0 (LSB) and Bit 1 : A status Bit 2 and Bit 3 : B status 00 - Off 01 - On 11 - Unknown - For FCD-W, NETWORK and USER ports - 1 Octet Status of Control Signals: '1'=On ; '0'=Off or when not applicable Bit - 7 6 5 4 3 2 1 0 Bit 7 (MSB) - Signal Loss (applicable only for G.703 interface) Bit 6 - CONTROL (applicable only for X.21 interface) Bit 5 - INDICATION (applicable only for X.21 interface) Bit 4 - DSR (applicable only for V.35 interface) Bit 3 - RTS (applicable only for V.35 interface) Bit 2 - CTS (applicable only for V.35 interface) Bit 1 - DTR (applicable only for V.35 interface) Bit 0 - DCD (applicable only for V.35 interface)
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

prtGenTestDurationTable 1.3.6.1.4.1.164.3.3.3.1.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtGenTestDurationEntry

prtGenTestDurationEntry 1.3.6.1.4.1.164.3.3.3.1.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtGenTestDurationEntry  

prtGenTestPrtIdx 1.3.6.1.4.1.164.3.3.3.1.2.1.1
This attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside/external, inside/internal. In the Kilomux, the port index is calculated as follows: 100*Slot+Ch. The external Ch numbers are 1..10, and the internal Ch numbers are 11..20. In the DXC : - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 .
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtGenTestIdx 1.3.6.1.4.1.164.3.3.3.1.2.1.2
This attribute indicates the test, the duration refers.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER localLoop(1), remoteLoop(2), bert(3), plb(4), rlb(5), llb(6), toneInjection(7), txInband(8), rxInband(9)  

prtGenTestDuration 1.3.6.1.4.1.164.3.3.3.1.2.1.3
This attribute indicates the maximum duration of executing a test on the specific port. This entry applies to the specified test . The resolution will be a minute, and the maximum duration is limited to 30 minutes . A zero value specifies no time limitation. When the test isn't active the agent initiates this object to 2 min. when the duration is needed and to 0 if it's not required.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

prtGenTsTable 1.3.6.1.4.1.164.3.3.3.1.3
The write operation into the Table's Objects is valid only for the TmpCnfg entry (Scratch).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtGenTsEntry

prtGenTsEntry 1.3.6.1.4.1.164.3.3.3.1.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtGenTsEntry  

prtGenTsCnfgIdx 1.3.6.1.4.1.164.3.3.3.1.3.1.1
This attribute indicates the Idx of the Cnfg(1..255) being accessed. Idx of 255 relates to the TmpCnfg.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtGenTsPrtIdx 1.3.6.1.4.1.164.3.3.3.1.3.1.2
This attribute indicates a unique port number. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. In the DXC : - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 .
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtGenTsIdx 1.3.6.1.4.1.164.3.3.3.1.3.1.3
This attribute indicates a unique time slot position. The valid time slots are 1..25 for T1 Card (25=Fbit) 0..31 for E1 or HS Card . In G732S-E1 lines time slot 16 is not valid for data, it is dedicated for multiframe synchronization bits and voice signaling.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtGenTsType 1.3.6.1.4.1.164.3.3.3.1.3.1.4
The type of Timeslot. If the source or destination port is an HS port,'TS Type' must be 'data'. nc - means that this TimeSlot is not connected. voice, data, vcMP - also mean that this TS is connected. mng - means that this TS is dedicated to Management (not connected to another port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), voice(2), data(3), vcMP(4), nc(5), mng(6)  

prtGenTsIConPrt 1.3.6.1.4.1.164.3.3.3.1.3.1.5
This attribute indicates the internally (In Mux) connected port. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. * The outside ports will be the T1/E1 cards ports. The convention used will be (for DXC): - first two digits will be: (IO slot number+10) for a stand-alone unit, the IO slot will be considered 1. - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside ports will be for example, the HS cards ports. The convention used will be (for DXC): - first two digits will be: (IO slot number+10) for a stand-alone unit, the IO slot will be considered 1. - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . * noConnection - will be indicated as 10 for DXC and FCD-E1/T1. - will be indicated as 100 for FCD-E1/I and SMODs. * Split TS (same TS is Split to several ports) - 11. All HS port's timeslots must have the same destination port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

prtGenTsIConTs 1.3.6.1.4.1.164.3.3.3.1.3.1.6
This attribute indicates a unique time slot position. The valid time slots are 1..25 for T1 Card (25=Fbit) 0..31 for E1 (or HS) Card. In G732S-E1 lines time slot 16 is not valid for data, it is dedicated for multiframe synchronization bits and voice signaling. * For DXC: All HS port's timeslots must start with Timeslot no.1
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

prtAlr 1.3.6.1.4.1.164.3.3.3.1.4
OBJECT IDENTIFIER    

prtSAlarmTable 1.3.6.1.4.1.164.3.3.3.1.4.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtSAlarmEntry

prtSAlarmEntry 1.3.6.1.4.1.164.3.3.3.1.4.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtSAlarmEntry  

prtSAlarmIdx 1.3.6.1.4.1.164.3.3.3.1.4.1.1.1
A unique number to identify an entry in the alarm status table. Users should use the get next function to read this table because the indexes are not consecutive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtSAlarmPrtIdx 1.3.6.1.4.1.164.3.3.3.1.4.1.1.2
This attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside/external, inside/internal. In the Kilomux, the port index is calculated as follows: 100*Slot+Ch. The external Ch numbers are 1..10, and the internal Ch numbers are 11..20. In the DXC : - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 .
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtSAlarmCode 1.3.6.1.4.1.164.3.3.3.1.4.1.1.3
This object indicates a code related to a specific alarm description. The list of codes and their related descriptions will be sent to NMS request (for display purpose) by alrGenTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtSAlarmState 1.3.6.1.4.1.164.3.3.3.1.4.1.1.4
This object indicates the port alarm state.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER minor(4), major(5)  

prtSAlarmMask 1.3.6.1.4.1.164.3.3.3.1.4.1.1.5
Alarm Mask is : on/off.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtSAlarmInvert 1.3.6.1.4.1.164.3.3.3.1.4.1.1.6
Alarm Invert is : on/off.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtAlrMaskTable 1.3.6.1.4.1.164.3.3.3.1.4.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtAlrMaskEntry

prtAlrMaskEntry 1.3.6.1.4.1.164.3.3.3.1.4.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtAlrMaskEntry  

prtAlrMaskPrtIdx 1.3.6.1.4.1.164.3.3.3.1.4.2.1.1
This attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside/external, inside/internal. In the Kilomux, the port index is calculated as follows: 100*Slot+Ch. The external Ch numbers are 1..10, and the internal Ch numbers are 11..20. In the DXC : - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 .
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtAlrMask 1.3.6.1.4.1.164.3.3.3.1.4.2.1.2
This object is a mask that indicates which port level alarms are masked. The masked alarms (their bit is set to '1') are neither sent to the manager, nor taken into account for alarm status and LEDs. Bit no. = Alarm code The bits that do not belong to the port level will be 0. This object is applicable only when prtGenAlrMaskAll=off (otherwise all port alarms are masked). Example: When Alarms having the codes 31 and 40 are masked, the value of this object will be 10080000000 (hex).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

prtBertTable 1.3.6.1.4.1.164.3.3.3.1.5
This table includes the BERT parameters, counters and commands. The configurable parameters: - prtBertPattern - prtBertInjectRate - prtBertTs are not Set per configuration (same for all Configurations) but start being applied by the Agent only upon successful Update/Download operation. Therefore, Set will enter the values to the Temporary Configuration of the agent, while Get will get the values of the Active Configuration.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtBertEntry

prtBertEntry 1.3.6.1.4.1.164.3.3.3.1.5.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtBertEntry  

prtBertPrtIdx 1.3.6.1.4.1.164.3.3.3.1.5.1.1
This attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside/external, inside/internal. In the Kilomux, the port index is calculated as follows: 100*Slot+Ch. The external Ch numbers are 1..10, and the internal Ch numbers are 11..20. In the DXC : - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . In the MP : - first two digits will be: (IO slot number+10) - last one/two digits will be according to the external port number within the card: exPrt1 -> 1 exPrt2 -> 3 exPrt3 -> 5 exPrt4 -> 7 .
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtBertPattern 1.3.6.1.4.1.164.3.3.3.1.5.1.2
This object indicates the pattern of the BERT. p2Exxm1 = 2Exx-1. pxx = pattern xx. This object is the same for all configurations. notApplicable - when this object is not supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER p2E3m1(1), p2E4m1(2), p2E5m1(3), p2E6m1(4), p2E7m1(5), p511(6), p2E10m1(7), p2047(8), p2E15m1(9), p2E17m1(10), p2E18m1(11), p2E20m1(12), qrss(13), p2E21m1(14), p2E22m1(15), p2E23m1(16), p2E25m1(17), p2E28m1(18), p2E29m1(19), p2E31m1(20), p2E32m1(21), rj011(22), p63(23), p1M7S(24), p1S7M(25), alternate(26), mark(27), space(28), notApplicable(255)  

prtBertInjectRate 1.3.6.1.4.1.164.3.3.3.1.5.1.3
This object indicates the error rate injection of the BERT. r10Emx = 10E-x This object is the same for all configurations. single - single error injection. notApplicable - when this object is not supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noError(1), r10Em1(2), r10Em2(3), r10Em3(4), r10Em4(5), r10Em5(6), r10Em6(7), r10Em7(8), single(9), notApplicable(255)  

prtBertInjectErrRateCmd 1.3.6.1.4.1.164.3.3.3.1.5.1.4
This object controls activation/deactivation of the Error Rate Injection during BERT.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtBertInjectSingleErrCmd 1.3.6.1.4.1.164.3.3.3.1.5.1.5
This object enables to initiate a Single Error Injection during BERT (on). Upon completion, the value will automatically change to off(2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtBertRunTime 1.3.6.1.4.1.164.3.3.3.1.5.1.6
This object indicates how much time (seconds) passed since BERT started to run.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtBertESs 1.3.6.1.4.1.164.3.3.3.1.5.1.7
How many Errored Seconds were detected since BERT started to run. Counter for Kmux and MP.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtBertSyncLoss 1.3.6.1.4.1.164.3.3.3.1.5.1.8
How many times Sync Loss was detected since BERT started to run. For some products: number of seconds in which Sync Loss occured since BERT started to run. See product specification.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtBertErrorBits 1.3.6.1.4.1.164.3.3.3.1.5.1.9
How many Error Bits were detected since BERT started to run.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtBertClearCounters 1.3.6.1.4.1.164.3.3.3.1.5.1.10
Setting this object to ON, will enforce a clear operation of some BERT Counters. Upon completion, the value will automatically change to off(2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtBertSyncStatus 1.3.6.1.4.1.164.3.3.3.1.5.1.11
Sync Status while BERT runs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), syncLoss(2), sync(3)  

prtBertTs 1.3.6.1.4.1.164.3.3.3.1.5.1.12
This object indicates on which TSs of the selected port, BERT should be applied. Each Bit of the Octet represents a TS: 31 ......0 MSB LSB Bit 0 will not be used. If the bit value is '1' - BERT should be applied on this TS. For a T1 port, the valid raised bits ('1') are: 1..25. For an E1 port, the valid raised bits ('1') are: 1..31. Agents that do not support this feature will send SIZE 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..4)  

prtMonTable 1.3.6.1.4.1.164.3.3.3.1.6
The write operation into the Table's Objects is valid only for the TmpCnfg entry (Scratch).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtMonEntry

prtMonEntry 1.3.6.1.4.1.164.3.3.3.1.6.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtMonEntry  

prtMonCnfgIdx 1.3.6.1.4.1.164.3.3.3.1.6.1.1
This object indicates the Idx of the Cnfg(1..255) being accessed. Idx of 255 relates to the TmpCnfg.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtMonitoringIdx 1.3.6.1.4.1.164.3.3.3.1.6.1.2
This object indicates the Monitoring Port Index. The valid port number depends on the IO slot no., the installed card type and the port type: external, internal. * The external ports will according to the convention (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The internal ports will be according to the convention (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 .
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtMonitoringEnable 1.3.6.1.4.1.164.3.3.3.1.6.1.3
This object indicates if the prtMonitoringIdx is configured as a monitoring port or not. disabled = the port is NOT configured to monitor. Setting this object to this value will cause reset (to 0) of the prtMonitoringTSs and prtMonitoredTSs objects. enabled = the port IS configured to monitor.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

prtMonitoringTSs 1.3.6.1.4.1.164.3.3.3.1.6.1.4
This object indicates which TSs of the Monitoring port, the test equipment should monitor. Each Bit of the Octet represents a TS: 31 ......0 MSB LSB Bit 0 will not be used. If the bit value is '1' - this TS should be monitored. For a T1 port, the valid raised bits ('1') are: 1..24. For an E1 port, the valid raised bits ('1') are: 1..31. Default: all bits='0' Agents that do not support this feature will send SIZE 0. This object can be Set as described only if prtMonitoringEnable=enabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..4)  

prtMonitoredPort 1.3.6.1.4.1.164.3.3.3.1.6.1.5
This object indicates the MONITORED Port Index that the Monitoring port monitors. The valid port number depends on the IO slot no., the installed card type and the port type: external, internal. * The external ports will according to the convention (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The internal ports will be according to the convention (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . * 100 - no port monitored
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

prtMonitoredTSs 1.3.6.1.4.1.164.3.3.3.1.6.1.6
This object indicates which TSs of the Monitored port, should be monitored. Each Bit of the Octet represents a TS: 31 ......0 MSB LSB Bit 0 will not be used. If the bit value is '1' - this TS should be monitored. For a T1 port, the valid raised bits ('1') are: 1..24. For an E1 port, the valid raised bits ('1') are: 1..31. Default: all bits='0' Agents that do not support this feature will send SIZE 0. This object can be Set as described only if prtMonitoringEnable=enabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..4)  

prtCfgParam 1.3.6.1.4.1.164.3.3.3.1.7
OBJECT IDENTIFIER    

prtCfgParamTable 1.3.6.1.4.1.164.3.3.3.1.7.1
The write operation into the Table Objects is valid only to the TmpCnfg entry. Parameters for the channels of the KMUX Cards: KMBE/New, KVF.6 family.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtCfgParamEntry

prtCfgParamEntry 1.3.6.1.4.1.164.3.3.3.1.7.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtCfgParamEntry  

prtCfgParamCnfgIdx 1.3.6.1.4.1.164.3.3.3.1.7.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtCfgParamIdx 1.3.6.1.4.1.164.3.3.3.1.7.1.1.2
A unique identifier of the port (within the card when applicable). - For KM-2100: Slot*100+Ch external ports: Ch=1..10 internal ports (sub-channels): Ch=11..20. - For FCD-T1/E1: SUB=113, CH1=122, CH2=124.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtCfgParamSlt 1.3.6.1.4.1.164.3.3.3.1.7.1.1.3
This attribute indicates a unique number to identify the slot where the card is inserted in. In the 2104 Unit the entries kmxIO5(111)..kmxIO12(118) are not valid. notApplicable(255) - for products that do not have Slots.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER kmxIO1(107), kmxIO2(108), kmxIO3(109), kmxIO4(110), kmxIO5(111), kmxIO6(112), kmxIO7(113), kmxIO8(114), kmxIO9(115), kmxIO10(116), kmxIO11(117), kmxIO12(118), notApplicable(255)  

prtCfgParamOperatedMl 1.3.6.1.4.1.164.3.3.3.1.7.1.1.4
The main link for this channel. The field is relevant only for ML modes of Dual, Priority Bumping and Switched Backup.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), kmxMlA(103), kmxMlB(104)  

prtCfgParamMlAtoMlBPrio 1.3.6.1.4.1.164.3.3.3.1.7.1.1.5
ML-A to ML-B Priority. The field is relevant only for ML modes of Priority Bumping and Switched Backup.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), low(2), high(3)  

prtCfgParamMlBtoMlAPrio 1.3.6.1.4.1.164.3.3.3.1.7.1.1.6
ML-B to ML-A Priority. The field is relevant only for ML modes of Priority Bumping.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), low(2), high(3)  

prtCfgParamInbandLoopDetection 1.3.6.1.4.1.164.3.3.3.1.7.1.1.7
Inband Loop Detection. The field is relevant for the following FCD-T1/E1 ports: SUB, CH1, CH2.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

prtT1E1StatTable 1.3.6.1.4.1.164.3.3.3.2.1
T1/E1 port statistics table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtT1E1StatEntry

prtT1E1StatEntry 1.3.6.1.4.1.164.3.3.3.2.1.1
An entry in the T1/E1 port statistics table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtT1E1StatEntry  

prtT1E1SPrtIdx 1.3.6.1.4.1.164.3.3.3.2.1.1.1
This attribute indicates a unique port number. The same numbering as for prtGenPrtIdx. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside. * The outside ports will be the T1/E1 cards ports. The convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 .
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtT1E1SSlt 1.3.6.1.4.1.164.3.3.3.2.1.1.2
This attribute indicates a unique number to identify the slot where the card is inserted in. When the unit is stand-alone, this object is not applicable and 255 will be used.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), standAlone(255)  

prtT1E1OosCount 1.3.6.1.4.1.164.3.3.3.2.1.1.3
This object is applicable only for an E1 active port. It provides the number of red alarm events since the last count clearing.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

prtT1E1BpvLastMin 1.3.6.1.4.1.164.3.3.3.2.1.1.4
This object is applicable only for an E1 active port. It provides the number of BPV (BiPolar Violation) events detected during the last minute.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

prtT1E1BpvMax 1.3.6.1.4.1.164.3.3.3.2.1.1.5
This object is applicable only for an E1 active port. It provides the maximal number of BPV (BiPolar Violation) events (per minute), detected during the worst minute.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

prtT1E1CnfgTable 1.3.6.1.4.1.164.3.3.3.2.2
T1/E1 port configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtT1E1CnfgEntry

prtT1E1CnfgEntry 1.3.6.1.4.1.164.3.3.3.2.2.1
An entry in the T1/E1 port configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtT1E1CnfgEntry  

prtT1E1CnfgIdx 1.3.6.1.4.1.164.3.3.3.2.2.1.1
This attribute indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtT1E1PrtIdx 1.3.6.1.4.1.164.3.3.3.2.2.1.2
This attribute indicates a unique port number. The same numbering as for prtGenPrtIdx. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside. In the DXC : - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . In the Kilomux, the port index is calculated as follows: 100*Slot+Ch. The external Ch numbers are 1..10, and the internal Ch numbers are 11..20.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtT1E1Slt 1.3.6.1.4.1.164.3.3.3.2.2.1.3
This attribute indicates a unique number to identify the slot where the card is inserted in. When the unit is stand-alone, this object is not applicable and 255 will be used.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), kmxMlA(103), kmxMlB(104), kmxOpt(106), kmxIO1(107), kmxIO2(108), kmxIO3(109), kmxIO4(110), kmxIO5(111), kmxIO6(112), kmxIO7(113), kmxIO8(114), kmxIO9(115), kmxIO10(116), kmxIO11(117), kmxIO12(118), standAlone(255)  

prtT1E1LineType 1.3.6.1.4.1.164.3.3.3.2.2.1.4
This variable indicates the variety of T1/E1 Line implementing this circuit. The type of circuit affects the number of bits per second that the circuit can reasonably carry, as well as the interpretation of the usage and error statistics. The values, in sequence, describe: TITLE: SPECIFICATION: esf Extended SuperFrame DS1 d4 AT&T D4 format DS1 - SF e1 CCITT Recommendation G.704 (Table 4a) - G732N e1Crc CCITT Recommendation G.704 (Table 4b) - G732N with CRC e1MF G.704 (Table 4a) with TS16 multiframing enabled - G732S e1CrcMF G.704 (Table 4b) with TS16 multiframing enabled - G732S with CRC unframed T1 - applicable values: (1),(2),(3),(8) E1 - applicable values: (1),(4),(5),(6),(7),(8)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), esf(2), d4(3), e1(4), e1Crc(5), e1MF(6), e1CrcMF(7), unframed(8)  

prtT1E1LineCode 1.3.6.1.4.1.164.3.3.3.2.2.1.5
This variable describes the variety of Zero Code Suppression used on the link, which in turn affects a number of its characteristics. jbzs=b7zs refers the Jammed Bit Zero Suppres- sion, in which the AT&T specification of at least one pulse every 8 bit periods is literal- ly implemented by forcing a pulse in bit 8 of each channel. Thus, only seven bits per chan- nel, or 1.344 Mbps, is available for data (used for T1). b8zs refers to the use of a specified pattern of normal bits and bipolar violations which are used to replace a sequence of eight zero bits (used for T1). ANSI Clear Channels may use zbtsi, or Zero Byte Time Slot Interchange. E1 links, with or without CRC, use hdb3 or ami (= TRAN). amI (=TRAN) refers to a mode wherein no zero code suppression is present and the line encoding does not solve the problem directly. In this application, the higher layer must provide data which meets or exceeds the pulse density re- quirements, such as inverting HDLC data.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER jbzs(1), b8zs(2), hdb3(3), zbtsi(4), ami(5), other(6)  

prtT1E1SignalMode 1.3.6.1.4.1.164.3.3.3.2.2.1.6
'none' indicates that no bits are reserved for signaling on this channel. 'robbedBit' indicates that T1 Robbed Bit Signaling is in use. 'bitOriented' indicates that E1 Channel Associated Signaling (CAS) is in use. 'messageOriented' indicates that Common Channel Signaling (CCS) is in use either on channel 16 of an E1 link or channel 24 of a T1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), robbedBit(2), bitOriented(3), messageOriented(4)  

prtT1E1Fdl 1.3.6.1.4.1.164.3.3.3.2.2.1.7
This bitmap describes the use of the facili- ties data link, and is the sum of the capabili- ties: 'other' indicates that a protocol other than one following is used. 'ansi-T1-403' refers to the FDL exchange recommended by ANSI. 'att-54016' refers to ESF FDL exchanges. 'fdl-none' indicates that the device does not use the FDL. 'transFdl' indicates transition between two ports of the same card.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), ansi-T1-403(2), att-54016(4), fdl-none(8), transFdl(16)  

prtT1E1FdlMode 1.3.6.1.4.1.164.3.3.3.2.2.1.8
Fdl Mode of the T1 selected port. notApplicable - will be used for an E1 port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), user(2), carrier(3), notApplicable(255)  

prtT1E1Sync 1.3.6.1.4.1.164.3.3.3.2.2.1.9
This object enables returning to normal operation, after the end of a main/sub link red alarm event, in reduced time. 'tr62411' - complies with AT&T TR-62411 (after 10 seconds). Applicable for both T1 and E1 interfaces. 'ccitt' - complies with CCITT standard. Applicable only for E1 interfaces. 'fast' - after 1 second.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), tr62411(2), ccitt(3), fast(4)  

prtT1E1CGA 1.3.6.1.4.1.164.3.3.3.2.2.1.10
This object selects the method used to signal the CGA state to the other end, through the main/sub link. 'none' - non-transparent mode. When one of the links (main/sub) will be in Out Of Service state, both 'Data/Voice Oos' and 'Oos Signal' will be transmitted to the other end. 'trans' - when one of the links (main/sub) will be in Out Of Service state, 'Data/Voice Oos' will be transmitted to the other end. 'full' - fully-transparent mode. When one of the links (main/sub) will be in Out Of Service state, neither 'Data/Voice Oos' nor 'Oos Signal' will be transmitted to the other end.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), trans(2), full(3)  

prtT1E1IdleCode 1.3.6.1.4.1.164.3.3.3.2.2.1.11
This object selects the code transmitted to fill idle (unused) time slots in the main link frame. Valid range: (0 - FF HEX) .
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..4)  

prtT1E1OosSignal 1.3.6.1.4.1.164.3.3.3.2.2.1.12
'idle' = '0' = on-hook, idle state 'busy' = '1' = off-hook, busy state 'forcedIdle' = SP = both A and B signaling bits are forced to '0' during out-of-service periods. 'forcedBusy' = MK = both A and B signaling bits are forced to '1' during out-of-service periods. 'busyIdle' = MK_SP = A and B bits are forced to '1' for 2.5 seconds; then they are switched to '0' until out-of-service condition disappears. 'idleBusy' = SP_MK = A and B bits are forced to '0' for 2.5 seconds; then they are switched to '1' until out-of-service condition disappears. - for T1: '0'=0 ; '1'=1 - for E1: '0'=1 ; '1'=0
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notsupported(2), forcedIdle(3), forcedBusy(4), busyIdle(5), idleBusy(6)  

prtT1E1VoiceOos 1.3.6.1.4.1.164.3.3.3.2.2.1.13
Voice Out-Of-Service code. Valid range: (0 - FF HEX). For agents that do not support this feature, the value will always be 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..4)  

prtT1E1DataOos 1.3.6.1.4.1.164.3.3.3.2.2.1.14
Data Out-Of-Service code. Valid range: (0 - FF HEX). For agents that do not support this feature, the value will always be 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..4)  

prtT1E1LineLengthMask 1.3.6.1.4.1.164.3.3.3.2.2.1.15
This attribute is the line length mask parameter used only for T1/DSU interfaces. len400p533ft=length range: 400ft to 533ft 'fcc68' - provides compliance with the FCC 68.308 Option A output pulse mask.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), len0p133ft(2), len134p266ft(3), len267p399ft(4), len400p533ft(5), len534p655ft(6), fcc68(7)  

prtT1E1TxGainMask 1.3.6.1.4.1.164.3.3.3.2.2.1.16
This attribute is the tx gain mask parameter (dB), used only for T1/CSU interfaces.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), txGain0db(2), txGain7dot5db(3), txGain15db(4), txGain22dot5db(5)  

prtT1E1InbandMng 1.3.6.1.4.1.164.3.3.3.2.2.1.17
A unique number to identify an Inband management over the link. internal - supported by KM-2100 only. It means that the management is internal to the frame. It takes part of the ML Frame bits (instead of data).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(2), fdlOrTs0(3), dedicatedTs(4), dedicatedPpp(5), dedicatedFr(6), internal(7)  

prtT1E1InbandMngRate 1.3.6.1.4.1.164.3.3.3.2.2.1.18
A unique number to identify the rate of the Inband management. It is required only for E1 links and is applicable only when prtExT1E1InbandMng selected is FdlOrTs0 or dedicatedTs.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), r4k(2), r8k(3), r12k(4), r16k(5), r32k(6), r64k(7), r20k(8)  

prtT1E1DedicatedTs 1.3.6.1.4.1.164.3.3.3.2.2.1.19
A unique number to identify Dedicated TS of the T1/E1 port. It is applicable only when prtExT1E1InbandMng selected is dedicatedTs. 1..24 - Dedicated TS of T1 1..31 - Dedicated TS of E1 255 - notApplicable (for agents that do not support this feature) Other values are invalid.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

prtT1E1InbandMngRoutProt 1.3.6.1.4.1.164.3.3.3.2.2.1.20
Inband Mng Routing Protocol of the port. When prtT1E1InbandMng is 'dedicatedPpp'-'proprietary' and 'rip2' are applicable. For other values - only 'proprietary' is applicable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), proprietary(3), rip2(4)  

prtT1E1LinkMode 1.3.6.1.4.1.164.3.3.3.2.2.1.21
regular - TSs are connected by user via TS Assignment only transparent - when a port with this Link Mode is connected to an internal T1/E1 port of a T3/E3 card, TS0, TS16 and Fbit are transparently transferred to the E3/T3 stream.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), regular(2), transparent(3)  

prtT1E1Multiplier 1.3.6.1.4.1.164.3.3.3.2.2.1.22
The data rate of each TS. The multiplier values can be 56 kbps or 64 kbps. For T1 only.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), br56(2), br64(3)  

prtT1E1RxGain 1.3.6.1.4.1.164.3.3.3.2.2.1.23
This attribute is the rx volume (dB).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), rxGain12dB(2), rxGain30dB(3), rxGain36dB(4), shortHaul(5), longHaul(6)  

prtT1E1RAI 1.3.6.1.4.1.164.3.3.3.2.2.1.24
Remote Alarm Signal
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3)  

prtT1E1LineMode 1.3.6.1.4.1.164.3.3.3.2.2.1.25
Interface type of the port. For T1 - csu, dsu are the valid values For E1 - dsu, ltu are the valid values
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), csu(2), dsu(3), ltu(4)  

prtT1E1TS0SaBits 1.3.6.1.4.1.164.3.3.3.2.2.1.26
This object is applicable only for E1 ports. For T1, string size will be 0. For E1, it enables user to select the use of TS0 Sa Bits 4..8, by 3 octets: The order (in hexa display): free Sa-Bit-4 Sa-Bit-5 Sa-Bit-6 Sa-Bit-7 Sa-Bit-8 |___________| |________________| |________________| MSByte LSByte Each Sa Bit will be represented by a nibble, having the following meaning: 0000 = zero 0001 = one 0010 = management 0011 = transparent the rest are reserved for future use.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

prtT1E1FdlMsgTable 1.3.6.1.4.1.164.3.3.3.2.3
This table is applicable for a T1 interface with 'esf' LineType or E1 interface, when CRC is enabled (LineType).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtT1E1FdlMsgEntry

prtT1E1FdlMsgEntry 1.3.6.1.4.1.164.3.3.3.2.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtT1E1FdlMsgEntry  

prtT1E1FdlMsgPrtIdx 1.3.6.1.4.1.164.3.3.3.2.3.1.1
This attribute indicates a unique port number. The same numbering as for prtGenPrtIdx. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside. * The outside ports will be the T1/E1 cards ports. The convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 .
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtT1E1FdlMsgFdlType 1.3.6.1.4.1.164.3.3.3.2.3.1.2
The Fdl type reference of the Fdl message.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER send(1), receive(2)  

prtT1E1FdlMsgSlt 1.3.6.1.4.1.164.3.3.3.2.3.1.3
This attribute indicates a unique number to identify the slot where the card is inserted in. When the unit is stand-alone, this object is not applicable and 255 will be used.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), standAlone(255)  

prtT1E1FdlMsg 1.3.6.1.4.1.164.3.3.3.2.3.1.4
FDL message.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

prtHSParamTable 1.3.6.1.4.1.164.3.3.3.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtHSParamEntry

prtHSParamEntry 1.3.6.1.4.1.164.3.3.3.3.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtHSParamEntry  

prtHSCnfgIdx 1.3.6.1.4.1.164.3.3.3.3.1.1.1
This attribute indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtHSPrtIdx 1.3.6.1.4.1.164.3.3.3.3.1.1.2
This attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. * The inside ports will be the HS cards ports. The convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 .
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtHSSlt 1.3.6.1.4.1.164.3.3.3.3.1.1.3
This attribute indicates a unique number to identify the slot where the card is inserted in. When the unit is stand-alone, this object is not applicable and 255 will be used.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), standAlone(255)  

prtHSRate 1.3.6.1.4.1.164.3.3.3.3.1.1.4
This object indicates the port rate (speed).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER r0x56eq0Kbps(1), r1x56eq56Kbps(2), r2x56eq112Kbps(3), r3x56eq168Kbps(4), r4x56eq224Kbps(5), r5x56eq280Kbps(6), r6x56eq336Kbps(7), r7x56eq392Kbps(8), r8x56eq448Kbps(9), r9x56eq504Kbps(10), r10x56eq560Kbps(11), r11x56eq616Kbps(12), r12x56eq672Kbps(13), r13x56eq728Kbps(14), r14x56eq784Kbps(15), r15x56eq840Kbps(16), r16x56eq896Kbps(17), r17x56eq952Kbps(18), r18x56eq1008Kbps(19), r19x56eq1064Kbps(20), r20x56eq1120Kbps(21), r21x56eq1176Kbps(22), r22x56eq1232Kbps(23), r23x56eq1288Kbps(24), r24x56eq1344Kbps(25), r25x56eq1400Kbps(26), r26x56eq1456Kbps(27), r27x56eq1512Kbps(28), r28x56eq1568Kbps(29), r29x56eq1624Kbps(30), r30x56eq1680Kbps(31), r31x56eq1736Kbps(32), r0x64eq0Kbps(33), r1x64eq64Kbps(34), r2x64eq128Kbps(35), r3x64eq192Kbps(36), r4x64eq256Kbps(37), r5x64eq320Kbps(38), r6x64eq384Kbps(39), r7x64eq448Kbps(40), r8x64eq512Kbps(41), r9x64eq576Kbps(42), r10x64eq640Kbps(43), r11x64eq704Kbps(44), r12x64eq768Kbps(45), r13x64eq832Kbps(46), r14x64eq896Kbps(47), r15x64eq960Kbps(48), r16x64eq1024Kbps(49), r17x64eq1088Kbps(50), r18x64eq1152Kbps(51), r19x64eq1216Kbps(52), r20x64eq1280Kbps(53), r21x64eq1344Kbps(54), r22x64eq1408Kbps(55), r23x64eq1472Kbps(56), r24x64eq1536Kbps(57), r25x64eq1600Kbps(58), r26x64eq1664Kbps(59), r27x64eq1728Kbps(60), r28x64eq1792Kbps(61), r29x64eq1856Kbps(62), r30x64eq1920Kbps(63), r31x64eq1984Kbps(64), r32x64eq2048Kbps(65), r32x56eq1792Kbps(66)  

prtHSFifoSize 1.3.6.1.4.1.164.3.3.3.3.1.1.5
This object selects the size of the user data channel buffer FIFO used in the DTE2 mode. In the other modes, buffer size is automatically set by the DACS agent. Buffer FIFO size in bits, corresponds to FIFO lengths of +/-16, +/-30, +/-52, +/-72 bits.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), b32bit(2), b60bit(3), b104bit(4), b144bit(5), notApplicable(255)  

prtHSClkMode 1.3.6.1.4.1.164.3.3.3.3.1.1.6
Clock Mode of the user data channel. dce - DACS operates as a DCE and provides transmit and receive clocks to the synchronous user DTE. dte1- DACS supplies the receive clock to the user equipment and accepts the user transmit clock. dte2- DACS requires transmit and receive clocks from the user equipment.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dce(1), dte1(2), dte2(3), notApplicable(255)  

prtHSCTS 1.3.6.1.4.1.164.3.3.3.3.1.1.7
Selection of CTS line state in the user data channel. on - CTS continuously ON. rts - CTS line follows the RTS line.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), rts(2)  

prtHSRtsState 1.3.6.1.4.1.164.3.3.3.3.1.1.8
RTS state of the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3), notApplicable(255)  

prtHSBertTable 1.3.6.1.4.1.164.3.3.3.3.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtHSBertEntry

prtHSBertEntry 1.3.6.1.4.1.164.3.3.3.3.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtHSBertEntry  

prtHSBertPrtIdx 1.3.6.1.4.1.164.3.3.3.3.2.1.1
This attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. * The inside ports will be the HS cards ports. The convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 .
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtHSBertSlt 1.3.6.1.4.1.164.3.3.3.3.2.1.2
This attribute indicates a unique number to identify the slot where the card is inserted in. When the unit is stand-alone, this object is not applicable and 255 will be used.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), standAlone(255)  

prtHSBertCountClr 1.3.6.1.4.1.164.3.3.3.3.2.1.3
Setting this object (to on) initiate bert counter clear operation. Valid only when bert test is active on the specific port. (Every time a new bert test starts, the counter is automatically cleared; this command enables clearing the counter while the test is running).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtHSBertTestResult 1.3.6.1.4.1.164.3.3.3.3.2.1.4
This object indicates the number of Bit Error Rate indicated during the BERT test. Active only when bert test is running on the selected port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtSpCnfgTable 1.3.6.1.4.1.164.3.3.3.4.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtSpCnfgEntry

prtSpCnfgEntry 1.3.6.1.4.1.164.3.3.3.4.1.1
All the entries at this table are identical(have the same value) at all the configurations(1..255) except at the TmpCnfg. - For products supporting more than one configuration, the write operation into the Table Objects is valid only at the TmpCnfg entry. - For products that do not support configurations, the write operation into the Table Objects will be to prtSpCnfgIdx=1.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtSpCnfgEntry  

prtSpCnfgIdx 1.3.6.1.4.1.164.3.3.3.4.1.1.1
This attribute indicates the Idx of the Cnfg(1..255) being accessed. Idx of 255 relates to the TmpCnfg.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtSpPrtIdx 1.3.6.1.4.1.164.3.3.3.4.1.1.2
This attribute indicates a unique port number of the SPor DP port. For DXC, it is the port in the active DCL card: - SP = 1 - NP ; DP = 2 For Kilomux, the port index is calculated as follows: 100*Slot+Ch. For FCD, PRBi, the SP port index=1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtSpUsage 1.3.6.1.4.1.164.3.3.3.4.1.1.3
This attribute indicates what is the usage of the port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), noUse(2), nmsSlip(3), nmsPpp(4), muxSlip(5), muxPpp(6), terminal(7), dialOut(8)  

prtSpRate 1.3.6.1.4.1.164.3.3.3.4.1.1.4
This attribute indicates the operation rate (speed) of the port. auto - automatic rate selection, by the agent.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), s300bps(2), s1200bps(3), s2400bps(4), s4800bps(5), s9600bps(6), s19200bps(7), s38400bps(8), s57600bps(9), s115200bps(10)  

prtSpDataBits 1.3.6.1.4.1.164.3.3.3.4.1.1.5
This attribute indicates the number of data bits in async frame
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dataBits7(1), dataBits8(2)  

prtSpParity 1.3.6.1.4.1.164.3.3.3.4.1.1.6
This attribute indicates the parity mode in async frame
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), odd(2), even(3)  

prtSpCallOutMode 1.3.6.1.4.1.164.3.3.3.4.1.1.7
This attribute indicates the call-out mode. For DXC - this object is applicable only for the DP port (2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), all(3), major(4)  

prtSpInterface 1.3.6.1.4.1.164.3.3.3.4.1.1.8
This attribute indicates the supervisory port interface. dce - the DACS appears as a DCE for the port. dte - the DACS operates as a DTE, for connection via modem, for the port. Port 2 - when DP, will be always dte(2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dce(1), dte(2)  

prtSpCTS 1.3.6.1.4.1.164.3.3.3.4.1.1.9
CTS line state. This object is applicable only for port (1) = SP
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), on(2), rts(3)  

prtSpDcdDelay 1.3.6.1.4.1.164.3.3.3.4.1.1.10
DCD delay in msec. d10 = delay of 10msec. This object is applicable only for port (1) = SP
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), d0(2), d10(3), d50(4), d100(5), d200(6), d300(7)  

prtSpDsr 1.3.6.1.4.1.164.3.3.3.4.1.1.11
DSR line state. This object is applicable only for port (1) = SP
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), on(2), dtr(3)  

prtSpNoOfRetries 1.3.6.1.4.1.164.3.3.3.4.1.1.12
For DXC - this object is applicable only for port (2) = DP. The number of dialing retries requested. Default = 0
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..8  

prtSpWaitForConnect 1.3.6.1.4.1.164.3.3.3.4.1.1.13
For DXC - this object is applicable only for port (2) = DP. Waiting time for connect, in seconds. Default = 30 sec.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), t30sec(2), t45sec(3), t60sec(4)  

prtSpDialMode 1.3.6.1.4.1.164.3.3.3.4.1.1.14
For DXC - this object is applicable only for port (2) = DP. Dialing mode. Default=tone
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), tone(2), pulse(3)  

prtSpAltNumMode 1.3.6.1.4.1.164.3.3.3.4.1.1.15
For DXC - this object is applicable only for port (2) = DP. It determines wether to use the alternate number or not. Default = no.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtSpPrimaryNum 1.3.6.1.4.1.164.3.3.3.4.1.1.16
For DXC - this object is applicable only for port (2) = DP. It is the Primary dialing number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..20)  

prtSpAltNum 1.3.6.1.4.1.164.3.3.3.4.1.1.17
For DXC - this object is applicable only for port (2) = DP. It is the Alternate dialing number. This number is applicable only if prtSpAltNumMode is 'yes'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..20)  

prtSpRoutProtocol 1.3.6.1.4.1.164.3.3.3.4.1.1.18
This attribute indicates the routing protocol of the port. notApplicable - for DP.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), proprietary(3), rip2(4)  

prtSpCmd 1.3.6.1.4.1.164.3.3.3.4.1.1.19
SP Command. For LRS this parameter will be used for a Modem Command. Upon NMS's Get operation for devices that this parameter is notApplicable, agent will send NULL string.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(20)  

prtSpActCallOut 1.3.6.1.4.1.164.3.3.3.4.1.1.20
This object indicates when to Activate Call-Out. It is used by FCD-T1/E1. always - to activate call-out always. linkFail - to activate call-out only when Link of Inband Management fails.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), always(2), linkFail(3)  

prtSpAlrRelayMode 1.3.6.1.4.1.164.3.3.3.4.1.1.21
This attribute indicates the Alarm Relay Mode. notApplicable - for DP.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), normal(2), invert(3)  

prtDimCnfgTable 1.3.6.1.4.1.164.3.3.3.5.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtDimCnfgEntry

prtDimCnfgEntry 1.3.6.1.4.1.164.3.3.3.5.1.1
The write operation into the Table Objects is valid only for the TmpCnfg entry (prtDimCnfgIdx=255).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtDimCnfgEntry  

prtDimCnfgIdx 1.3.6.1.4.1.164.3.3.3.5.1.1.1
This attribute indicates the Idx of the Cnfg(1..255) being accessed. Idx of 255 relates to the TmpCnfg.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtDimIdx 1.3.6.1.4.1.164.3.3.3.5.1.1.2
This attribute indicates a unique port number of the DIM card. The convention used for DXC: (IO slot number+10)*10 + 1 Example: port1 of IO slot 11 will be: 211 .
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtDimTxMode 1.3.6.1.4.1.164.3.3.3.5.1.1.3
Tx mode. regularTx - the links are connected to a similar outfit on the other side. In this mode, if a link fails, the transmitted bandwidth is decreased accordingly. broadcast - the links are connected to MORE than one similar outfit on the other side. In this mode, if a link fails, the transmitted bandwidth is not affected
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER regularTx(2), broadcast(3)  

prtDimPolarity 1.3.6.1.4.1.164.3.3.3.5.1.1.4
Polarity.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normalClk(2), inverted(3)  

prtDimClkMode 1.3.6.1.4.1.164.3.3.3.5.1.1.5
Clock Mode. smooth - a clock that is not 'pulsed'(has no 'gaps'). In this mode the DXC does NOT receive back the clock signal. extSmooth - same as 'smooth' but in this mode, the DXC receives back the clock signal.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER extDce(2), dce(3), smooth(4), extSmooth(5)  

prtDimMaxDelay 1.3.6.1.4.1.164.3.3.3.5.1.1.6
Max Delay permitted between the links, in msec.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER t16msec(2), t64msec(3)  

prtDimMng 1.3.6.1.4.1.164.3.3.3.5.1.1.7
Use of DIM port for management. disabled - no management on DIM ts1 - 1 bit of TS1 is used for management.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(2), ts1(3)  

prtDimDestTable 1.3.6.1.4.1.164.3.3.3.5.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtDimDestEntry

prtDimDestEntry 1.3.6.1.4.1.164.3.3.3.5.2.1
The write operation is valid only for the TmpCnfg entry (prtDimDestCnfgIdx=255).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtDimDestEntry  

prtDestCnfgIdx 1.3.6.1.4.1.164.3.3.3.5.2.1.1
This attribute indicates the Idx of the Cnfg(1..255) being accessed. Idx of 255 relates to the TmpCnfg.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtDestDimIdx 1.3.6.1.4.1.164.3.3.3.5.2.1.2
This attribute indicates a unique port number of the DIM card. The convention used for DXC: (IO slot number+10)*10 + 1 Example: port1 of IO slot 11 will be: 211 .
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtDestIdx 1.3.6.1.4.1.164.3.3.3.5.2.1.3
This attribute indicates a destination number of the DIM card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..8  

prtDest 1.3.6.1.4.1.164.3.3.3.5.2.1.4
Destination port,(of a T1/E1 port), that is connected to the DIM card, for the specified Destination number. 0 = No destination port. Else: For external ports: (IO Slot+10)*10 + 1 for port 1 (IO Slot+10)*10 + 3 for port 2 Example: port2 of IO slot 12 will be: 223 . For internal ports : (IO Slot+10)*10 + 2 for port 1 (IO Slot+10)*10 + 4 for port 2 (IO Slot+10)*10 + 6 for port 3 (IO Slot+10)*10 + 8 for port 4, etc...
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

prtDestConnect 1.3.6.1.4.1.164.3.3.3.5.2.1.5
Connection Status of the specified destination number. For a specified destination port, it depends both on the status of the port and on the status of the far-end port. Since this is a RO object, same value will be received for all configurations.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtICnfgTable 1.3.6.1.4.1.164.3.3.3.6.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtICnfgEntry

prtICnfgEntry 1.3.6.1.4.1.164.3.3.3.6.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtICnfgEntry  

prtICnfgIdx 1.3.6.1.4.1.164.3.3.3.6.1.1.1
This attribute indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtIIdx 1.3.6.1.4.1.164.3.3.3.6.1.1.2
This attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. * The ISDN B1, B2, D channels will be inside ports. For port index, see product specification.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtIRate 1.3.6.1.4.1.164.3.3.3.6.1.1.3
This object indicates the port rate in bits. Each TS contains 8 bits. Thus, 1 bit is equivalent to 8Kbps rate.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), nc(2), r2bit(3), r4bit(4), r8bit(5)  

prtIConnect 1.3.6.1.4.1.164.3.3.3.6.1.1.4
D channel connection. no - disconnected yes - connected.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtHdslTable 1.3.6.1.4.1.164.3.3.3.7.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtHdslEntry

prtHdslEntry 1.3.6.1.4.1.164.3.3.3.7.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtHdslEntry  

prtHdslIdx 1.3.6.1.4.1.164.3.3.3.7.1.1.1
This attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside. * The HDSL ports will be external. For port index, see product specification.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtHdslMode 1.3.6.1.4.1.164.3.3.3.7.1.1.2
This object indicates the HDSL mode.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), central(2), remote(3)  

prtHdslRptrType 1.3.6.1.4.1.164.3.3.3.7.1.1.3
The Repeater between Near and Far modem. none - no repeater exists between the modems hrpt - HRPT repeater exists between the modems.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), hrpt(3)  

prtT3E3CnfgTable 1.3.6.1.4.1.164.3.3.3.8.1
T3/E3 port configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtT3E3CnfgEntry

prtT3E3CnfgEntry 1.3.6.1.4.1.164.3.3.3.8.1.1
An entry in the T3/E3 port configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PrtT3E3CnfgEntry  

prtT3E3CnfgIdx 1.3.6.1.4.1.164.3.3.3.8.1.1.1
This attribute indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config. Write operations can be performed only on the Temp Config.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

prtT3E3PrtIdx 1.3.6.1.4.1.164.3.3.3.8.1.1.2
This attribute indicates a unique port number. The same numbering as for prtGenPrtIdx. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside. * The external ports convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 .
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prtT3E3Slt 1.3.6.1.4.1.164.3.3.3.8.1.1.3
This attribute indicates a unique number to identify the slot where the card is inserted in. When the unit is stand-alone, this object is not applicable and 255 will be used.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), standAlone(255)  

prtT3E3LineLength 1.3.6.1.4.1.164.3.3.3.8.1.1.4
This object is the length of the ds3 line in feet. It provides information for line build out circuitry if it exists and can use this object to adjust the line build out. len0p450ft = 0 - 450 feet len451p900ft = 451 - 900 feet.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), len0p450ft(2), len451p900ft(3)  

prtT3E3InbandMng 1.3.6.1.4.1.164.3.3.3.8.1.1.5
A unique number to identify the Frame Type over the link.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), cBit(3), cBitTxRxMng(4), cBitTx(5), cBitTxMng(6), m13(7)  

cmprTable 1.3.6.1.4.1.164.3.3.4.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CmprEntry

cmprEntry 1.3.6.1.4.1.164.3.3.4.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CmprEntry  

cmprTypeIdx 1.3.6.1.4.1.164.3.3.4.1.1.1
This object indicates the Type of the Compressed data referred (which table, which level, etc). The type is a code according to a convention between agent and NMS.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cmprCnfgIdx 1.3.6.1.4.1.164.3.3.4.1.1.2
This object indicates the configuration number the Compressed information relates to.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cmprVersion 1.3.6.1.4.1.164.3.3.4.1.1.3
This object indicates the version of the internal format of the Compressed data (the version of the convention used).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cmprSltIdx 1.3.6.1.4.1.164.3.3.4.1.1.4
This attribute indicates a unique number of the slot position where the card is inserted. When the unit is stand-alone or this object is not applicable, 255 will be used.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER psA(1), psB(2), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), notApplicable(255)  

cmprPrtIdx 1.3.6.1.4.1.164.3.3.4.1.1.5
This object indicates a unique identifier of the port, the compressed information relates to. For DXC - according to the order in the card of cmprSltIdx: - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . For FCD: see product's specification. If the port number is irrelevant to this parameter (if it is a system/card level alarm) the value will be 9999.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cmprObj 1.3.6.1.4.1.164.3.3.4.1.1.6
This object is the compressed information itself, according to a predefined format, both agent and NMS agreed about.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

mapLinkTable 1.3.6.1.4.1.164.3.3.4.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MapLinkEntry

mapLinkEntry 1.3.6.1.4.1.164.3.3.4.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MapLinkEntry  

mapLinkIdx 1.3.6.1.4.1.164.3.3.4.2.1.1
A unique identifier of the link
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mapLinkSlotIdx 1.3.6.1.4.1.164.3.3.4.2.1.2
This attribute indicates a unique slot position where the module is inserted.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), standAlone(255)  

mapLinkPortIdx 1.3.6.1.4.1.164.3.3.4.2.1.3
This attribute indicates a unique port number. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. In the DXC : - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 .
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mapLinkState 1.3.6.1.4.1.164.3.3.4.2.1.4
This attribute indicates the status of the link between the two muxes
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), down(2), up(3)  

alrGenTable 1.3.6.1.4.1.164.3.3.4.3
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AlrGenEntry

alrGenEntry 1.3.6.1.4.1.164.3.3.4.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AlrGenEntry  

alrGenCode 1.3.6.1.4.1.164.3.3.4.3.1.1
This object is a unique code number, identifying a certain alarm.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

alrGenDescription 1.3.6.1.4.1.164.3.3.4.3.1.2
This entry is a unique text description, of the alarm corresponding to the specified code.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

alrGenLevel 1.3.6.1.4.1.164.3.3.4.3.1.3
Alarm level.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), system(2), card(3), port(4)  

alrGenSlotType 1.3.6.1.4.1.164.3.3.4.3.1.4
Slot type that the alarm is relevant to. clAndIo - an alarm that is relevant for both CL and IO slots.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), ps(2), cl(3), io(4), clAndIo(5)  

alrGenSeverity 1.3.6.1.4.1.164.3.3.4.3.1.5
This object enables the user to select a severity for each alarm. The severity is set per alarm code (same for all slots/ports using this code).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), minor(4), major(5)  

alrGenDebounce 1.3.6.1.4.1.164.3.3.4.3.1.6
Debounce time for each alarm code, in seconds. The meaning is, that an alarm will be 'declared' as ON (or OFF), only after it was actually ON/OFF the Debouncing time selected by user. 0 = default debounce selection (each alarm has a default value). 1 = minimum value of seconds for debounce. 255 = mask = the alarm will Never be reported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

sanityCheckTrap 1
This trap is sent after a data base download attempt. It returns the sanity result status and the configuration no.checked.
TRAP-TYPE    

dacsMuxAlarmsTrap 2
This trap is sent when an alarm occurs.
TRAP-TYPE    

mdlConnectTrap 3
This trap is sent when a card is removed.
TRAP-TYPE    

sysAlrStatusTrap 4
This trap is sent upon any change in the value of any of the variables.
TRAP-TYPE    

sysStatusChangedTrap 5
This trap is sent when Leds status is changed.
TRAP-TYPE    

cnfgUpdateTrap 6
This trap is sent upon change of the active Configuration DB.
TRAP-TYPE