DASAN-NOTIFICATION

File: DASAN-NOTIFICATION.mib (118531 bytes)

Imported modules

DASAN-DHCP-MIB DASAN-GEPON-MIB DASAN-SMI
DASAN-SWITCH-MIB DASAN-USER-MANAGEMENT-MIB SLE-FAULTMGMT-MIB
IF-MIB SNMPv2-MIB SNMPv2-SMI

Imported symbols

dsSubnetConfName dsPonOltIndex dsPonOnuIndex
dsPonOnuMacAddress dsPonTaggedLabel dsPonPortIndex
dsPonDirection dsPonState dsPonCount
dsPonQueueIndex dasanEvents dsFreeMem
dsSystemUpgradePath dsSystemUpgradeStorage dsPortModuleIndex
dsPortPortIndex dsPortInstallStatus dsTemperatureStatus
dsPowerIndex dsPowerstatus dsFanIndex
dsFanstatus dsUserMacAddress1 dsUserMacAddress2
dsUserMacAddress3 dsUserMacAddress4 dsSwitchAtNetAddress
dsSwitchAtMacAddress dsSwitchAtVID dsUserLoginName
dsUserLoginIpAddress sleY1731MegIndex sleY1731MEgRaspWestPortStatus
sleY1731MEgRaspEastPortStatus ifIndex sysDescr
sysUpTime NOTIFICATION-TYPE

Defined Values

portInstalled 1.3.6.1.4.1.6296.0.1
portI0nstalled trap send when portInstallStatus is enabled.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

portRemoved 1.3.6.1.4.1.6296.0.2
portInstalled trap send when portInstallStatus is disabled.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

powerOk 1.3.6.1.4.1.6296.0.3
Power status OK trap when powerStatus change from disable to enable.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

powerFail 1.3.6.1.4.1.6296.0.4
Power status fail trap when powerStatus change from enable to disable.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

fanOk 1.3.6.1.4.1.6296.0.5
Fan status OK trap when fanStatus change from disable to enable.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

fanFail 1.3.6.1.4.1.6296.0.6
Fan status fail trap when fanStatus change from enable to disable.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

powerInstalled 1.3.6.1.4.1.6296.0.7
Power Installed trap when power was installed.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

powerRemoved 1.3.6.1.4.1.6296.0.8
Power removed trap when power was removed.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

fanInstalled 1.3.6.1.4.1.6296.0.9
Fan Installed trap when fan was installed.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

fanRemoved 1.3.6.1.4.1.6296.0.10
Fan removed trap when fan was removed.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

bcastOver 1.3.6.1.4.1.6296.0.11
Broadcast packet over trap when Rx broadcast packet is over the given limit.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

cpuLoadOverThreshold 1.3.6.1.4.1.6296.0.12
The cpuLoadOverThreshold trap is sent when cpuLoad is over the given limit.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

cpuLoadFallThreshold 1.3.6.1.4.1.6296.0.13
The cpuLoadfallThreshold trap is sent when cpuLoad fall under the given limit.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

dhcpLeaseShortage 1.3.6.1.4.1.6296.0.14
DHCP User IP pool shortage when User's DHCPDISCOVER message arrive.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

portOverThreshold 1.3.6.1.4.1.6296.0.15
Port traffic over HighThreshold trap when port traffic is over the given limit.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

portFallThreshold 1.3.6.1.4.1.6296.0.16
Port traffic fall under HighThreshold trap when port traffic falls below the given limit.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

temperatureOverThreshold 1.3.6.1.4.1.6296.0.17
TemperatureOverThreshold Trap is sent when temperature is over the certain threshold.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

systemRestart 1.3.6.1.4.1.6296.0.18
SystemRestart Trap is sent when system is restarted by user. sleAutoResetBootReason is only used for auto-reset
Status: current Access: not-accessible
NOTIFICATION-TYPE    

mfgdBlocked 1.3.6.1.4.1.6296.0.19
mfgdblocked Trap is sent when a certain mac address is denied by mac-flood-guard mechanism.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

mfgdReleased 1.3.6.1.4.1.6296.0.20
mfgdReleased Trap is sent when a certain mac address is permitted again by mac-flood-guard mechanism.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ipConflict 1.3.6.1.4.1.6296.0.21
ipConflict Trap is sent when a certain IP address is shared among different users.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

dhcpIllegalEntry 1.3.6.1.4.1.6296.0.22
dhcpIllegalEntry trap is sent when illegal dhcp user is found.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

optionModuleInstalled 1.3.6.1.4.1.6296.0.23
optionModuleInstalled Trap is sent when option Module was installed.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

optionModuleRemoved 1.3.6.1.4.1.6296.0.24
optionModuleRemoved Trap is sent when option Module was removed.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

memoryOverThreshold 1.3.6.1.4.1.6296.0.25
MemoryOverThreshold trap is sent when used memory size is over the given limit and free memory size falls below the given limit.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

memoryFallThreshold 1.3.6.1.4.1.6296.0.26
MemoryFallThreshold trap is sent when free memory size is over the given limit.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

slotInstalled 1.3.6.1.4.1.6296.0.27
slotInstalledTrap Trap is sent when Board was installed.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

slotRemoved 1.3.6.1.4.1.6296.0.28
slotRemovedTrap Trap is sent when Board was removed.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

slotStateChange 1.3.6.1.4.1.6296.0.29
slotStateChangeTrap Trap is sent when Board State change.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

portCRCOverThreshold 1.3.6.1.4.1.6296.0.30
portCRCOverThreshold Trap is sent when the CRC count of port over threshold.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

portCRCFallThreshold 1.3.6.1.4.1.6296.0.31
portCRCOverThreshold Trap is sent when the CRC count of port fall threshold.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

temperatureHighOverThreshold 1.3.6.1.4.1.6296.0.32
The temperatureHighOverThreshold Trap is sent when temperature is over the high-threshold.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

temperatureHighFallThreshold 1.3.6.1.4.1.6296.0.33
The temperatureHighFallThreshold Trap is sent when temperature fall the high-threshold.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

temperatureLowOverThreshold 1.3.6.1.4.1.6296.0.34
The temperatureLowOverThreshold Trap is sent when 1st temperature is over the low-threshold.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

temperatureLowFallThreshold 1.3.6.1.4.1.6296.0.35
The temperatureLowFallThreshold Trap is sent when temperature fall under the low-threshold.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

userLogIn 1.3.6.1.4.1.6296.0.36
The user-login trap is sent when user login.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

userLogOut 1.3.6.1.4.1.6296.0.37
The user-logout trap is sent when user logout.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

restoreFactory 1.3.6.1.4.1.6296.0.38
The restoreFactory trap is sent when user initialize as factory defaults.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

cpuLoadHighOverThreshold 1.3.6.1.4.1.6296.0.39
The cpuloadHighOverThreshold Trap is sent when temperature is over the high-threshold.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

cpuLoadHighFallThreshold 1.3.6.1.4.1.6296.0.40
The cpuloadHighFallThreshold Trap is sent when temperature fall the high-threshold.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

cpuLoadLowOverThreshold 1.3.6.1.4.1.6296.0.41
The cpuloadLowOverThreshold Trap is sent when 1st temperature is over the low-threshold.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

cpuLoadLowFallThreshold 1.3.6.1.4.1.6296.0.42
The cpuloadLowFallThreshold Trap is sent when temperature fall under the low-threshold.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

dsSystemUpgradeChanged 1.3.6.1.4.1.6296.0.44
System NOS Upgrade status
Status: current Access: not-accessible
NOTIFICATION-TYPE    

interfaceOperDown 1.3.6.1.4.1.6296.0.45
This trap indicates the interface oper down.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

interfaceOperUp 1.3.6.1.4.1.6296.0.46
This trap indicates the interface poer up.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

macLearnOverMax 1.3.6.1.4.1.6296.0.47
This trap indicates the count of L2 mac is over the max.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

macLearnOverMaxCleared 1.3.6.1.4.1.6296.0.48
This trap indicates the count of L2 mac is over the max is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

interfaceMacLearnOverMax 1.3.6.1.4.1.6296.0.49
This trap indicates the count of interface's L2 mac is over the max.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

interfaceMacLearnOverMaxCleared 1.3.6.1.4.1.6296.0.50
This trap indicates the count of interface's L2 mac is over the max is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

adslAtucPerfLofsThresh 1.3.6.1.4.1.6296.0.51
Loss of Framing threshold reached(ATUC).
Status: current Access: not-accessible
NOTIFICATION-TYPE    

adslAtucPerfLossThresh 1.3.6.1.4.1.6296.0.52
Loss of signal threshold reached(ATUC).
Status: current Access: not-accessible
NOTIFICATION-TYPE    

adslAtucPerfLprsThresh 1.3.6.1.4.1.6296.0.53
Loss of power threshold reached (ATUC).
Status: current Access: not-accessible
NOTIFICATION-TYPE    

adslAtucPerfESsThresh 1.3.6.1.4.1.6296.0.54
Errored Seconds threshold reached (ATUC).
Status: current Access: not-accessible
NOTIFICATION-TYPE    

adslAtucRateChange 1.3.6.1.4.1.6296.0.55
Changed atuc rate.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

adslAtucPerfLolsThresh 1.3.6.1.4.1.6296.0.56
Loss of Link threshold reached (ATUC).
Status: current Access: not-accessible
NOTIFICATION-TYPE    

adslAturPerfLofsThresh 1.3.6.1.4.1.6296.0.61
Loss of Framing threshold reached(ATUR).
Status: current Access: not-accessible
NOTIFICATION-TYPE    

adslAturPerfLossThresh 1.3.6.1.4.1.6296.0.62
Loss of signal threshold reached(ATUR).
Status: current Access: not-accessible
NOTIFICATION-TYPE    

adslAturPerfLprsThresh 1.3.6.1.4.1.6296.0.63
Loss of power threshold reached (ATUR).
Status: current Access: not-accessible
NOTIFICATION-TYPE    

adslAturPerfESsThresh 1.3.6.1.4.1.6296.0.64
Errored Seconds threshold reached (ATUR).
Status: current Access: not-accessible
NOTIFICATION-TYPE    

vdslCPEChangeInfoTrap 1.3.6.1.4.1.6296.0.65
Trap is sent with CPE Serial No., Mac Address of CPE, after CPE serial change.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

vdslArulePacketDropTrap 1.3.6.1.4.1.6296.0.66
Packet Dropped by arule .
Status: current Access: not-accessible
NOTIFICATION-TYPE    

portMododuleInstall 1.3.6.1.4.1.6296.0.69
port module install
Status: current Access: not-accessible
NOTIFICATION-TYPE    

portMododuleRemove 1.3.6.1.4.1.6296.0.70
port module remove
Status: current Access: not-accessible
NOTIFICATION-TYPE    

cfgdBlocked 1.3.6.1.4.1.6296.0.71
Cfgdblocked Trap is sent when a certain port is blocked by cpu-flood-guard mechanism.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

cfgdReleased 1.3.6.1.4.1.6296.0.72
CfgdReleased Trap is sent when a certain port is non-blocked by cpu-flood-guard mechanism.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

cfgdOverThreshold 1.3.6.1.4.1.6296.0.73
CfgdReleased Trap is sent when a certain port is over threshold by cpu-flood-guard mechanism.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

cfgdUnderThreshold 1.3.6.1.4.1.6296.0.74
CfgdReleased Trap is sent when a certain port is under threshold by cpu-flood-guard mechanism.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfgdBlocked 1.3.6.1.4.1.6296.0.75
Sfgdblocked Trap is sent when a certain port is blocked by system-flood-guard mechanism.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfgdReleased 1.3.6.1.4.1.6296.0.76
SfgdReleased Trap is sent when a certain port is non-blocked by system-flood-guard mechanism.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfgdOverThreshold 1.3.6.1.4.1.6296.0.77
SfgdReleased Trap is sent when a certain port is over threshold by system-flood-guard mechanism.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfgdUnderThreshold 1.3.6.1.4.1.6296.0.78
SfgdReleased Trap is sent when a certain port is under threshold by system-flood-guard mechanism.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ppsControlBlocked 1.3.6.1.4.1.6296.0.79
PpsControlblocked Trap is sent when a certain port is blocked by PPS-Control mechanism.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ppsControlReleased 1.3.6.1.4.1.6296.0.80
PpsControlReleased Trap is sent when a certain port is non-blocked by PPS-Control mechanism.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ppsControlOverThreshold 1.3.6.1.4.1.6296.0.81
PpsControlReleased Trap is sent when a certain port is over threshold by PPS-Control mechanism.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ppsControlUnderThreshold 1.3.6.1.4.1.6296.0.82
PpsControlReleased Trap is sent when a certain port is under threshold by PPS-Control mechanism.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

nosRemoteUpgradeRequest 1.3.6.1.4.1.6296.0.83
This trap indicates that the system received nos-remote-upgrade command.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

nosRemoteUpgradeSuccess 1.3.6.1.4.1.6296.0.84
This trap indicates that the NOS succeeded to upgrade NOS.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

nosRemoteUpgradeFailAbort 1.3.6.1.4.1.6296.0.85
This trap indicates that the system failed to upgrade NOS by user interrupt
Status: current Access: not-accessible
NOTIFICATION-TYPE    

nosRemoteUpgradeFailHeaderError 1.3.6.1.4.1.6296.0.86
This trap indicates that the system failed to upgrade NOS, for NOS header-error.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

nosRemoteUpgradeFailDownloadError 1.3.6.1.4.1.6296.0.87
This trap indicates that the system failed to upgrade NOS, for NOS checksum-error
Status: current Access: not-accessible
NOTIFICATION-TYPE    

nosRemoteUpgradeFailFlashError 1.3.6.1.4.1.6296.0.88
This trap indicates that the system failed to upgrade NOS, for flash operation
Status: current Access: not-accessible
NOTIFICATION-TYPE    

nosRemoteUpgradeStart 1.3.6.1.4.1.6296.0.89
This trap indicates that the upgrade NOS process was started.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

systemDyingGasp 1.3.6.1.4.1.6296.0.90
This trap indicates that Dying-gasp for power fault.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

attackGuardBlock 1.3.6.1.4.1.6296.0.91
This trap indicates that some port is blocked by attack-guard.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

attackGuardUnBlock 1.3.6.1.4.1.6296.0.92
This trap indicates that some port is unblocked by attack-guard.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

fanPeriodicFault 1.3.6.1.4.1.6296.0.93
This trap indicates the fan status is fault in some period.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

remoteOamDyingGasp 1.3.6.1.4.1.6296.0.94
This trap indicates the remote oam entity is in dying-gasp .
Status: current Access: not-accessible
NOTIFICATION-TYPE    

remoteOamDyingGaspRestoration 1.3.6.1.4.1.6296.0.95
This trap indicates the remote oam entity is restored.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

arpInspectInvalid 1.3.6.1.4.1.6296.0.96
This trap indicates the ARP inspection is invalided.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

systemSwitchover 1.3.6.1.4.1.6296.0.97
This trap indicates the system is switchover.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

boardChangeState 1.3.6.1.4.1.6296.0.98
This trap indicates the board state is changed.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

redConfigurationMisMatch 1.3.6.1.4.1.6296.0.99
Configurations of Active and Standby SFU are different.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

clockModuleInstalled 1.3.6.1.4.1.6296.0.105
clockModuleInstalled trap send when sleClockModuleInstallStatus is installed.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

clockModuleRemoved 1.3.6.1.4.1.6296.0.106
clockModuleRemoved trap send when sleClockModuleInstallStatus is removed.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

clockModuleInitOk 1.3.6.1.4.1.6296.0.107
clockModuleInitOk trap send when sleClockModuleInitStatus is ok.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

clockModuleInitFail 1.3.6.1.4.1.6296.0.108
clockModuleInitFail trap send when sleClockModuleInitStatus is failure.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

interfaceAdminUp 1.3.6.1.4.1.6296.0.109
This trap indicates the interface admin up.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

interfaceAdminDown 1.3.6.1.4.1.6296.0.110
This trap indicates the interface admin down.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

powerMonEventDetected 1.3.6.1.4.1.6296.0.111
This trap indicates the power monitoring detects voltage change of slot.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ntpConnectionFail 1.3.6.1.4.1.6296.0.112
This trap indicates the ntp connection is lost.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

fanSpeedFallUnderThreshold 1.3.6.1.4.1.6296.0.113
This trap indicates the fan speed is under the threshold.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

fanSpeedRisingOverThreshold 1.3.6.1.4.1.6296.0.114
This trap indicates the fan speed is over the threshold.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

userLoginFail 1.3.6.1.4.1.6296.0.115
This trap indicates the user fail to login.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

bfdSessionStateChanged 1.3.6.1.4.1.6296.0.116
This trap indicates that BFD session state is changed.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

clockModuleOPModeChanged 1.3.6.1.4.1.6296.0.117
This trap indicate that slot Operation mode is changed.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

clockModuleRefrencesChanged 1.3.6.1.4.1.6296.0.118
This trap indicate that slot reference ntr is changed.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

portOperUp 1.3.6.1.4.1.6296.0.119
This trap indicate that port operation is up.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

portOperDown 1.3.6.1.4.1.6296.0.120
This trap indicate that port operation is down
Status: current Access: not-accessible
NOTIFICATION-TYPE    

portRxOverThreshold 1.3.6.1.4.1.6296.0.121
Port Rx traffic over HighThreshold trap when port traffic is over the given limit.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

portRxFallThreshold 1.3.6.1.4.1.6296.0.122
Port Rx traffic fall under HighThreshold trap when port traffic falls below the given limit.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

portTxOverThreshold 1.3.6.1.4.1.6296.0.123
Port Tx traffic over HighThreshold trap when port traffic is over the given limit.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

portTxFallThreshold 1.3.6.1.4.1.6296.0.124
Port Tx traffic fall under HighThreshold trap when port traffic falls below the given limit.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

clockModuleInSrcStatusChanged 1.3.6.1.4.1.6296.0.125
This trap indicate that module status is changed.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

clockModuleInSrcAISStatusChanged 1.3.6.1.4.1.6296.0.126
This trap indicate that AIS status is changed.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

clockModuleInSrcLoSStatusChaged 1.3.6.1.4.1.6296.0.127
This trap indicate that LOS status is changed.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

clockModuleInSrcLDSCStatus 1.3.6.1.4.1.6296.0.128
This trap indicate that LDSC status is changed.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

clockModuleInSrcNtrClockChanged 1.3.6.1.4.1.6296.0.129
This trap indicate that NTR is changed.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

reloadMateSFU 1.3.6.1.4.1.6296.0.130
This trap indicate that reload mate SFU.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

processDown 1.3.6.1.4.1.6296.0.131
This trap indicate that certain process is crashed and restarted.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

processTimeout 1.3.6.1.4.1.6296.0.132
This trap indicate that certain process is timeout.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sdcardInstalled 1.3.6.1.4.1.6296.0.133
This trap indicate that SD card is installed.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sdcardRemoved 1.3.6.1.4.1.6296.0.134
This trap indicate that SD card is removed.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

bootedNonDefaultOS 1.3.6.1.4.1.6296.0.141
This trap indicate that the system started with non-default OS.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

slotBootedNonDefaultOS 1.3.6.1.4.1.6296.0.142
This trap indicate that the IU card started with non-default OS.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

cpuPpsOverThreshold 1.3.6.1.4.1.6296.0.145
The PPS of cpu is over the threshold.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

cpuPpsUnderThreshold 1.3.6.1.4.1.6296.0.146
The PPS of cpu is under the threshold.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

redundantPacketDetected 1.3.6.1.4.1.6296.0.147
Redundant packets is detected.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

redundantPacketDetectedCleared 1.3.6.1.4.1.6296.0.148
Redundant packets detection is cleared.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponLinkFault 1.3.6.1.4.1.6296.0.151
ONU reports a Link Fault via the flag in the 802.3ah OAM header.No further information about the fault is available..
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponLos 1.3.6.1.4.1.6296.0.152
Loss of Signal is detected by the PHY device for OLT Network interface, and PON interfaces on the OLT and ONU.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponTransmitFail 1.3.6.1.4.1.6296.0.153
Transmitted output does not match input, as reported by EPON optics.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponTransmitDegrade 1.3.6.1.4.1.6296.0.154
Transmitted output has a high error level, but not so high as to cause - Failure. Optionallyreported by EPON optical module.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponQueueOverflow 1.3.6.1.4.1.6296.0.155
One of the queues for the link has dropped frames due to becoming full.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponMacLearningTableOverflow 1.3.6.1.4.1.6296.0.156
MAC address learning table is full, not in overwrite mode, and a new MAC address wasencountered.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponDuplicateMacRegistration 1.3.6.1.4.1.6296.0.157
MPCP register request received for MAC that is registered and in-service.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponReportTimeout 1.3.6.1.4.1.6296.0.158
ONU does not respond to grants from the OLT.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponGateTimeout 1.3.6.1.4.1.6296.0.159
Excessive interval between MPCP gates.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOAMKeepaliveTimeout 1.3.6.1.4.1.6296.0.160
OAM KeepaliveTimeout - OAM layer does not receive periodic messages from its peer.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponKeyExchangeFailure 1.3.6.1.4.1.6296.0.161
The link peer has failed to generate a new key message, or to switch to the new key, in the timeallotted by the key exchange timer for this link. Encryption remains in force using the old key, and the key exchange process continues.The alarm will clear when a new key is established.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponAutoNegotiation 1.3.6.1.4.1.6296.0.162
OLT Network port fails to auto-negotiate with the peer (if auto-negotiation feature is enabled).
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponLinkLoopback 1.3.6.1.4.1.6296.0.163
The link is currently in the loopback state.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponStandardDyingGasp 1.3.6.1.4.1.6296.0.164
ONU reports Dying Gasp via that bit in 802.3ah OAM header.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponPowerFail 1.3.6.1.4.1.6296.0.165
Power supply failure.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponTemperature 1.3.6.1.4.1.6296.0.166
Operating temperature range exceeded.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponAuthenticationInformationUnavailable 1.3.6.1.4.1.6296.0.167
ONU is configured to use external authentication device, and that device is not present.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOctetsTransferred 1.3.6.1.4.1.6296.0.171
Octets Transferred.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponTotalFramesTransferred 1.3.6.1.4.1.6296.0.172
Total frames transferred.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponUnicastFramesTransferred 1.3.6.1.4.1.6296.0.173
Unicast frames transferred.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponBroadcastFramesTransferred 1.3.6.1.4.1.6296.0.174
Broadcast frames transferred.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponMulticastFramesTransferred 1.3.6.1.4.1.6296.0.175
Multicast frames transferred.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponCRC32Errors 1.3.6.1.4.1.6296.0.176
CRC-32 Errors.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponUndersizeFrames 1.3.6.1.4.1.6296.0.177
Undersize Frames.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOversizeFrames 1.3.6.1.4.1.6296.0.178
Oversize Frames.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponCollisions 1.3.6.1.4.1.6296.0.179
Collisions.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

pon64OctetFrames 1.3.6.1.4.1.6296.0.180
64 Octet Frames.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

pon127OctetFrames 1.3.6.1.4.1.6296.0.181
65-127 Octet Frames.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

pon255OctetFrames 1.3.6.1.4.1.6296.0.182
128-255 Octet Frames.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

pon511OctetFrames 1.3.6.1.4.1.6296.0.183
256-511 Octet Frames.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

pon1023OctetFrames 1.3.6.1.4.1.6296.0.184
512-1023 Octet Frames.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

pon1518OctetFrames 1.3.6.1.4.1.6296.0.185
1024-1518 Octet Frames.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

pon1519OverOctetFrames 1.3.6.1.4.1.6296.0.186
1519+ Octet Frames.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponFramesDropped 1.3.6.1.4.1.6296.0.187
Frames dropped.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOctetsDropped 1.3.6.1.4.1.6296.0.188
Octets dropped.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOctetsDelayed 1.3.6.1.4.1.6296.0.189
Octets delayed.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOctetsGranted 1.3.6.1.4.1.6296.0.190
Octets granted.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOctetsGrantedButUnused 1.3.6.1.4.1.6296.0.191
Octets granted but unused.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponMaximumDelay 1.3.6.1.4.1.6296.0.192
Maximum Delay (units of 100usec).
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponCRC8Errors 1.3.6.1.4.1.6296.0.193
CRC-8 (preamble) Errors.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponLineCodeErrors 1.3.6.1.4.1.6296.0.194
Line code errors
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponPauseFrames 1.3.6.1.4.1.6296.0.195
Pause Frames
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponErroredFrameSeconds 1.3.6.1.4.1.6296.0.196
Errored Frame Seconds
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponErroredFramePeriod 1.3.6.1.4.1.6296.0.197
Errored Frame Period
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponErroredFrameSecondsSummary 1.3.6.1.4.1.6296.0.198
Errored Frame Seconds Summary
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuRegistered 1.3.6.1.4.1.6296.0.200
Registered Onu Informations
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuDeregistered 1.3.6.1.4.1.6296.0.201
Deregistered Onu Informations
Status: current Access: not-accessible
NOTIFICATION-TYPE    

swWatchdogDetectError 1.3.6.1.4.1.6296.0.202
S/W Watchdog Detect Error
Status: current Access: not-accessible
NOTIFICATION-TYPE    

swWatchdogClearError 1.3.6.1.4.1.6296.0.203
S/W Watchdog Clear Error
Status: current Access: not-accessible
NOTIFICATION-TYPE    

swWatchdogNormalState 1.3.6.1.4.1.6296.0.204
S/W Watchdog Normal State
Status: current Access: not-accessible
NOTIFICATION-TYPE    

swWatchdogAbnomalState 1.3.6.1.4.1.6296.0.205
S/W Watchdog Abnormal State
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuUpgradeCompleted 1.3.6.1.4.1.6296.0.206
Upgrade Completed Onu Informations
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltCableDown 1.3.6.1.4.1.6296.0.207
GPON Cable down event is detected.(This is not used for any product)
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuAutoToManual 1.3.6.1.4.1.6296.0.208
GPON Onu is auto-to-manual
Status: current Access: not-accessible
NOTIFICATION-TYPE    

slotActionEvent 1.3.6.1.4.1.6296.0.209
This trap indicates the slot action event
Status: current Access: not-accessible
NOTIFICATION-TYPE    

slotStateChanged 1.3.6.1.4.1.6296.0.210
This trap indicates the slot state is changed
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponNoAuthONU 1.3.6.1.4.1.6296.0.211
No autheticated ONU
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponDuplicateONU 1.3.6.1.4.1.6296.0.212
Duplicated ONU
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponDyingGasp 1.3.6.1.4.1.6296.0.213
Dying Gasp of GPON ONU
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponRogueOnu 1.3.6.1.4.1.6296.0.214
Found Rogue ONU.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuBatteryEvent 1.3.6.1.4.1.6296.0.215
Battery Event.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuBatteryEventCleared 1.3.6.1.4.1.6296.0.216
Battery Event is cleared.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuPortOperStatus 1.3.6.1.4.1.6296.0.217
This trap indicates state of ONU Port Operation.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponTransceiverChanged 1.3.6.1.4.1.6296.0.218
This trap indicates GPON transceiver changed.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltLosOn 1.3.6.1.4.1.6296.0.219
This trap indicates state of OLT Loss Of Signal (on).
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltLosOff 1.3.6.1.4.1.6296.0.220
This trap indicates state of OLT Loss Of Signal (off).
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltLosiOn 1.3.6.1.4.1.6296.0.221
This trap indicates state of OLT Loss Of Signal for ONUi (on).
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltLosiOff 1.3.6.1.4.1.6296.0.222
This trap indicates state of OLT Loss Of Signal for ONUi (off).
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponDyingGaspOn 1.3.6.1.4.1.6296.0.223
This trap indicates Dying Gasp of GPON ONU (on).
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponDyingGaspOff 1.3.6.1.4.1.6296.0.224
This trap indicates Dying Gasp of GPON ONU (off).
Status: current Access: not-accessible
NOTIFICATION-TYPE    

slotErrorLEDChanged 1.3.6.1.4.1.6296.0.225
This trap indicates slot error LED changed.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

nmsConnectionTypeChanged 1.3.6.1.4.1.6296.0.226
This trap indicates NMS connection type changed.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOntOSUpgradeStatus 1.3.6.1.4.1.6296.0.227
This trap indicates ONT OS upgrade status changes.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOntBLUpgradeStatus 1.3.6.1.4.1.6296.0.228
This trap indicates ONT BL upgrade status changes.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOntRxPowerLoss 1.3.6.1.4.1.6296.0.229
This trap indicates ONT port failed to detect Rx Power.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOntRxPowerDetected 1.3.6.1.4.1.6296.0.230
This trap indicates ONT port detected Rx Power.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuTemperatureHighOverThreshold 1.3.6.1.4.1.6296.0.231
This trap indicates the temperature of ONU is over high threshold.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuTemperatureHighFallThreshold 1.3.6.1.4.1.6296.0.232
This trap indicates the temperature of ONU falls under high threshold.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuTemperatureLowOverThreshold 1.3.6.1.4.1.6296.0.233
This trap indicates the temperature of ONU is over low threshold.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuTemperatureLowFallThreshold 1.3.6.1.4.1.6296.0.234
This trap indicates the temperature of ONU falls under low threshold.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuCpuOverThreshold 1.3.6.1.4.1.6296.0.235
This trap indicates the CPU-load of ONU is over threshold.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuCpuFallThreshold 1.3.6.1.4.1.6296.0.236
This trap indicates the CPU-load of ONU falls under threshold.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuMemoryOverThreshold 1.3.6.1.4.1.6296.0.237
This trap indicates the memory-utilization of ONU is over threshold.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuMemoryFallThreshold 1.3.6.1.4.1.6296.0.238
This trap indicates the memory-utilization of ONU falls under threshold.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuI2cFail 1.3.6.1.4.1.6296.0.239
This trap indicates that detect ONU's i2c fail.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuRxOpticPowerLowThreshAlarmOn 1.3.6.1.4.1.6296.0.240
RX optic low power alarm is detected
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuRxOpticPowerLowThreshAlarmOff 1.3.6.1.4.1.6296.0.241
RX optic low power alarm is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuRxOpticPowerHighThreshAlarmOn 1.3.6.1.4.1.6296.0.242
RX Optic over power alarm is detected
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuRxOpticPowerHighThreshAlarmOff 1.3.6.1.4.1.6296.0.243
RX Optic over power alarm is cleared.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltLOFIOn 1.3.6.1.4.1.6296.0.244
OLT LOFI alarm is detected
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltLOFIOff 1.3.6.1.4.1.6296.0.245
OLT LOFI alarm is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltDOWOn 1.3.6.1.4.1.6296.0.246
OLT DOW alarm is detected
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltDOWOff 1.3.6.1.4.1.6296.0.247
OLT DOW alarm is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltSFOn 1.3.6.1.4.1.6296.0.248
OLT SF alarm is detected
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltSFOff 1.3.6.1.4.1.6296.0.249
OLT SF alarm is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltSDOn 1.3.6.1.4.1.6296.0.250
OLT SD alarm is detected
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltSDOff 1.3.6.1.4.1.6296.0.251
OLT SD alarm is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltLCDGIOn 1.3.6.1.4.1.6296.0.252
OLT LCDGI alarm is detected
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltLCDGIOff 1.3.6.1.4.1.6296.0.253
OLT LCDGI alarm is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltRDOn 1.3.6.1.4.1.6296.0.254
OLT RD alarm is detected
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltRDOff 1.3.6.1.4.1.6296.0.255
OLT RD alarm is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltSUFOn 1.3.6.1.4.1.6296.0.256
OLT SUF alarm is detected
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltSUFOff 1.3.6.1.4.1.6296.0.257
OLT SUF alarm is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltLOAOn 1.3.6.1.4.1.6296.0.258
OLT LOA alarm is detected
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltLOAOff 1.3.6.1.4.1.6296.0.259
OLT LOA alarm is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltLOAMIOn 1.3.6.1.4.1.6296.0.260
OLT LOAMI alarm is detected
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltLOAMIOff 1.3.6.1.4.1.6296.0.261
OLT LOAMI alarm is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltMEMOn 1.3.6.1.4.1.6296.0.262
OLT MEM alarm is detected
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltMEMOff 1.3.6.1.4.1.6296.0.263
OLT MEM alarm is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltPEEOn 1.3.6.1.4.1.6296.0.264
OLT PEE alarm is detected
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltPEEOff 1.3.6.1.4.1.6296.0.265
OLT PEE alarm is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltPSTOn 1.3.6.1.4.1.6296.0.266
OLT PST alarm is detected
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltPSTOff 1.3.6.1.4.1.6296.0.267
OLT PST alarm is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltERROn 1.3.6.1.4.1.6296.0.268
OLT alarm error is detected
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltERROff 1.3.6.1.4.1.6296.0.269
OLT alarm error is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltREIOn 1.3.6.1.4.1.6296.0.270
OLT REI alarm is detected
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltREIOff 1.3.6.1.4.1.6296.0.271
OLT REI alarm is cleared.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponAntiSpoofingDupPortOn 1.3.6.1.4.1.6296.0.272
Anti spoofing duplication port alarm is detected
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponAntiSpoofingDupPortOff 1.3.6.1.4.1.6296.0.273
Anti spoofing duplication port alarm is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponRedundancySwitchOver 1.3.6.1.4.1.6296.0.274
Redundancy switch over
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponDuplicatedRangingResponse 1.3.6.1.4.1.6296.0.275
Duplicated ranging response detection.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuPortOpticModuleInstall 1.3.6.1.4.1.6296.0.276
ONU port optic module install detection.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuPortOpticModuleRemove 1.3.6.1.4.1.6296.0.277
ONU port optic module removal detection.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuOMCCProblemDetected 1.3.6.1.4.1.6296.0.278
ONU OMCC Problem is detected.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuOMCCProblemCleared 1.3.6.1.4.1.6296.0.279
ONU OMCC Problem is cleared.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltFixedTcontAlarmOn 1.3.6.1.4.1.6296.0.280
OLT fixed tcont alarm is detected
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltFixedTcontAlarmOff 1.3.6.1.4.1.6296.0.281
OLT fixed tcont alarm is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltDynamicTcontAlarmOn 1.3.6.1.4.1.6296.0.282
OLT dynamic tcont alarm is detected.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltDynamicTcontAlarmOff 1.3.6.1.4.1.6296.0.283
OLT dynamic tcont alarm is cleared.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltPortCountAlarmOn 1.3.6.1.4.1.6296.0.284
OLT port count alarm is detected.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltPortCountAlarmOff 1.3.6.1.4.1.6296.0.285
OLT port count alarm is cleared.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltCableDownAlarmOn 1.3.6.1.4.1.6296.0.286
GPON Cable down event is detected
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltCableDownAlarmOff 1.3.6.1.4.1.6296.0.287
GPON Cable down event is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltDeactiveMonitorAlarmOn 1.3.6.1.4.1.6296.0.288
GPON deactive monitor alarm is on
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltDeactiveMonitorAlarmOff 1.3.6.1.4.1.6296.0.289
GPON deactive monitor alarm is off
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltDFION 1.3.6.1.4.1.6296.0.290
GPON OLT DFI is on
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltDFIOFF 1.3.6.1.4.1.6296.0.291
GPON OLT DFI is off
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltTransceiverPortChanged 1.3.6.1.4.1.6296.0.294
GPON OLT Transceiver alarm is changed
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltRxOpticPowerHighThresOver 1.3.6.1.4.1.6296.0.295
GPON OLT power high threshold is over
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltRxOpticPowerHighThresOverCleared 1.3.6.1.4.1.6296.0.296
GPON OLT power high threshold over is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltRxOpticPowerLowThresUnder 1.3.6.1.4.1.6296.0.297
GPON OLT power low threshold is under
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOltRxOpticPowerLowThresUnderCleared 1.3.6.1.4.1.6296.0.298
GPON OLT power low threshold under is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

oamRapsEastPortStatusChanged 1.3.6.1.4.1.6296.0.301
The east port status changed
Status: current Access: not-accessible
NOTIFICATION-TYPE    

oamRapsWestPortStatusChanged 1.3.6.1.4.1.6296.0.302
The west port status changed
Status: current Access: not-accessible
NOTIFICATION-TYPE    

oamURNodePortStatusChanged 1.3.6.1.4.1.6296.0.303
OAM uplink redundancy node's port status changed
Status: current Access: not-accessible
NOTIFICATION-TYPE    

loopDetectBlocked 1.3.6.1.4.1.6296.0.320
This trap indicate the Port is blocked by loop-detect.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

loopDetectUnBlockedbyExpireTimer 1.3.6.1.4.1.6296.0.321
This trap indicate the Port is unblocked by loop-detect's expire timer.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

loopDetectUnBlockedbyLinkDown 1.3.6.1.4.1.6296.0.322
This trap indicate the Port is unblocked by loop-detect's link down.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

writeMemoryFailSeveralTimes 1.3.6.1.4.1.6296.0.341
This trap indicates the writing memory is failed 3 times
Status: current Access: not-accessible
NOTIFICATION-TYPE    

writeMemoryFailSeveralTimesCleared 1.3.6.1.4.1.6296.0.342
This trap indicates the writing memory is ok
Status: current Access: not-accessible
NOTIFICATION-TYPE    

emLogDefectCPUHighOver 1.3.6.1.4.1.6296.0.351
EM log about CPU load high over.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

emLogDefectCPUHighUnder 1.3.6.1.4.1.6296.0.352
EM log about CPU load high under.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

emLogTemperHighOver 1.3.6.1.4.1.6296.0.353
EM log about temperature high over.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

emLogTemperHighUnder 1.3.6.1.4.1.6296.0.354
EM log about temperature high under.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

emLogTemperLowUnder 1.3.6.1.4.1.6296.0.355
EM log about temperature low under (occured).
Status: current Access: not-accessible
NOTIFICATION-TYPE    

emLogTemperLowOver 1.3.6.1.4.1.6296.0.356
EM log about temperature low under (cleared).
Status: current Access: not-accessible
NOTIFICATION-TYPE    

emLogMemLowUnder 1.3.6.1.4.1.6296.0.358
EM log about memory low over (occured).
Status: current Access: not-accessible
NOTIFICATION-TYPE    

emLogMemLowOver 1.3.6.1.4.1.6296.0.357
EM log about memory low over (cleared).
Status: current Access: not-accessible
NOTIFICATION-TYPE    

emLogFanFail 1.3.6.1.4.1.6296.0.359
EM log about fan fail.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

emLogFanFailCleared 1.3.6.1.4.1.6296.0.360
EM log about fan fail cleared.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

emLogPhyCRCFail 1.3.6.1.4.1.6296.0.361
EM log about PHY CRC fail.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

emLogPhyCRCFailCleared 1.3.6.1.4.1.6296.0.362
EM log about PHY CRC fail cleared.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

emLogPhyDetectFail 1.3.6.1.4.1.6296.0.363
EM log about PHY detect fail.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

emLogPhyDetectFailCleared 1.3.6.1.4.1.6296.0.364
EM log about PHY detect fail cleared.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

emLogSFUMateInitFail 1.3.6.1.4.1.6296.0.365
EM log about SFU mate init fail
Status: current Access: not-accessible
NOTIFICATION-TYPE    

emLogSFUMateInitFailCleared 1.3.6.1.4.1.6296.0.366
EM log about SFU mate init fail cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

emLogDaemonHealthBad 1.3.6.1.4.1.6296.0.367
EM log about daemon health bad
Status: current Access: not-accessible
NOTIFICATION-TYPE    

emLogDaemonHealthBadCleared 1.3.6.1.4.1.6296.0.368
EM log about daemon health bad cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

emLogGPIURavenLinkDown 1.3.6.1.4.1.6296.0.369
EM log about GPIU raven link down
Status: current Access: not-accessible
NOTIFICATION-TYPE    

emLogGPIURavenLinkDownCleared 1.3.6.1.4.1.6296.0.370
EM log about GPIU raven link down cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

bootSequenceConfigFile 1.3.6.1.4.1.6296.0.371
Boot Sequence Config File failed
Status: current Access: not-accessible
NOTIFICATION-TYPE    

topologyChanged 1.3.6.1.4.1.6296.0.372
Topolgy changed
Status: current Access: not-accessible
NOTIFICATION-TYPE    

configLoadFail 1.3.6.1.4.1.6296.0.373
Config load failed
Status: current Access: not-accessible
NOTIFICATION-TYPE    

emlogFanRPMLow 1.3.6.1.4.1.6296.0.375
FAN RPM Low detected in EMLOG
Status: current Access: not-accessible
NOTIFICATION-TYPE    

emlogFanRPMLowCleared 1.3.6.1.4.1.6296.0.376
FAN RPM Low cleared in EMLOG
Status: current Access: not-accessible
NOTIFICATION-TYPE    

emlogNAKError 1.3.6.1.4.1.6296.0.377
NAK Error detected in EMLOG
Status: current Access: not-accessible
NOTIFICATION-TYPE    

emlogNAKErrorCleared 1.3.6.1.4.1.6296.0.378
NAK Error cleared in EMLOG
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuAniVoltageLowThreshAlarmOn 1.3.6.1.4.1.6296.0.381
Voltage low threshold alarm on
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuAniVoltageLowThreshAlarmOff 1.3.6.1.4.1.6296.0.382
Voltage low threshold alarm off
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuAniVoltageHighThreshAlarmOn 1.3.6.1.4.1.6296.0.383
Voltage high threshold alarm on
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuAniVoltageHighThreshAlarmOff 1.3.6.1.4.1.6296.0.384
Voltage high threshold alarm off
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuAniTemperatureLowThreshAlarmOn 1.3.6.1.4.1.6296.0.385
Temperature low threshold alarm on
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuAniTemperatureLowThreshAlarmOff 1.3.6.1.4.1.6296.0.386
Temperature high threshold alarm off
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuAniTemperatureHighThreshAlarmOn 1.3.6.1.4.1.6296.0.387
Temperature high threshold alarm on
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuAniTemperatureHighThreshAlarmOff 1.3.6.1.4.1.6296.0.388
Temperature high threshold alarm off
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuAniTxBiasLowThreshAlarmOn 1.3.6.1.4.1.6296.0.389
TX-bias low threshold alarm on
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuAniTxBiasLowThreshAlarmOff 1.3.6.1.4.1.6296.0.390
TX-bias low threshold alarm off
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuAniTxBiasHighThreshAlarmOn 1.3.6.1.4.1.6296.0.391
TX-bias high threshold alarm on
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuAniTxBiasHighThreshAlarmOff 1.3.6.1.4.1.6296.0.392
TX-bias high threshold alarm off
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuAniTxpowerLowThreshAlarmOn 1.3.6.1.4.1.6296.0.393
TX-power low threshold alarm on
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuAniTxpowerLowThreshAlarmOff 1.3.6.1.4.1.6296.0.394
TX-power low threshold alarm off
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuAniTxpowerHighThreshAlarmOn 1.3.6.1.4.1.6296.0.395
TX-power high threshold alarm on
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuAniTxpowerHighThreshAlarmOff 1.3.6.1.4.1.6296.0.396
TX-power high threshold alarm off
Status: current Access: not-accessible
NOTIFICATION-TYPE    

slotHealthStatusTimeout 1.3.6.1.4.1.6296.0.397
This trap indicates the slot health status time-out is occurred
Status: current Access: not-accessible
NOTIFICATION-TYPE    

slotHealthStatusTimeoutCleared 1.3.6.1.4.1.6296.0.398
This trap indicates the slot health status time-out trap is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfpDMIDiagTemperOverHighAlarm 1.3.6.1.4.1.6296.0.401
This trap indicates the temperature of sfp is over the high threshold.(Alarm)
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfpDMIDiagTemperUnderHighAlarm 1.3.6.1.4.1.6296.0.402
This trap indicates the temperature of sfp is under the high threshold.(Alarm)
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfpDMIDiagTemperUnderLowAlarm 1.3.6.1.4.1.6296.0.403
This trap indicates the temperature of sfp is under the low threshold.(Alarm)
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfpDMIDiagTemperOverLowAlarm 1.3.6.1.4.1.6296.0.404
This trap indicates the temperature of sfp is over the low threshold.(Alarm)
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfpDMIDiagTemperOverHighWarn 1.3.6.1.4.1.6296.0.405
This trap indicates the temperature of sfp is over the high threshold.(Warn)
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfpDMIDiagTemperUnderHighWarn 1.3.6.1.4.1.6296.0.406
This trap indicates the temperature of sfp is under the high threshold.(Warn)
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfpDMIDiagTemperUnderLowWarn 1.3.6.1.4.1.6296.0.407
This trap indicates the temperature of sfp is under the low threshold.(Warn)
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfpDMIDiagTemperOverLowWarn 1.3.6.1.4.1.6296.0.408
This trap indicates the temperature of sfp is over the low threshold.(Warn)
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfpDMIDiagVoltageOverHighAlarm 1.3.6.1.4.1.6296.0.409
This trap indicates the voltage of sfp is over the high threshold.(Alarm)
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfpDMIDiagVoltageUnderHighAlarm 1.3.6.1.4.1.6296.0.410
This trap indicates the voltage of sfp is under the high threshold.(Alarm)
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfpDMIDiagVoltageUnderLowAlarm 1.3.6.1.4.1.6296.0.411
This trap indicates the voltage of sfp is under the low threshold.(Alarm)
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfpDMIDiagVoltageOverLowAlarm 1.3.6.1.4.1.6296.0.412
This trap indicates the voltage of sfp is over the low threshold.(Alarm)
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfpDMIDiagVoltageOverHighWarn 1.3.6.1.4.1.6296.0.413
This trap indicates the voltage of sfp is over the high threshold.(Warn)
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfpDMIDiagVoltageUnderHighWarn 1.3.6.1.4.1.6296.0.414
This trap indicates the voltage of sfp is under the high threshold.(Warn)
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfpDMIDiagVoltageUnderLowWarn 1.3.6.1.4.1.6296.0.415
This trap indicates the voltage of sfp is under the low threshold.(Warn)
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfpDMIDiagVoltageOverLowWarn 1.3.6.1.4.1.6296.0.416
This trap indicates the voltage of sfp is over the low threshold.(Warn)
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfpDMIDiagTxBiasOverHighAlarm 1.3.6.1.4.1.6296.0.417
This trap indicates the TxBias of sfp is over the high threshold.(Alarm)
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfpDMIDiagTxBiasUnderHighAlarm 1.3.6.1.4.1.6296.0.418
This trap indicates the TxBias of sfp is under the high threshold.(Alarm)
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfpDMIDiagTxBiasUnderLowAlarm 1.3.6.1.4.1.6296.0.419
This trap indicates the TxBias of sfp is under the low threshold.(Alarm)
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfpDMIDiagTxBiasOverLowAlarm 1.3.6.1.4.1.6296.0.420
This trap indicates the TxBias of sfp is over the low threshold.(Alarm)
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfpDMIDiagTxBiasOverHighWarn 1.3.6.1.4.1.6296.0.421
This trap indicates the TxBias of sfp is over the high threshold.(Warn)
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfpDMIDiagTxBiasUnderHighWarn 1.3.6.1.4.1.6296.0.422
This trap indicates the TxBias of sfp is under the high threshold.(Warn)
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfpDMIDiagTxBiasUnderLowWarn 1.3.6.1.4.1.6296.0.423
This trap indicates the TxBias of sfp is under the low threshold.(Warn)
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfpDMIDiagTxBiasOverLowWarn 1.3.6.1.4.1.6296.0.424
This trap indicates the TxBias of sfp is over the low threshold.(Warn)
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfpDMIDiagTxPowerOverHighAlarm 1.3.6.1.4.1.6296.0.425
This trap indicates the TxPower of sfp is over the high threshold.(Alarm)
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfpDMIDiagTxPowerUnderHighAlarm 1.3.6.1.4.1.6296.0.426
This trap indicates the TxPower of sfp is under the high threshold.(Alarm)
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfpDMIDiagTxPowerUnderLowAlarm 1.3.6.1.4.1.6296.0.427
This trap indicates the TxPower of sfp is under the low threshold.(Alarm)
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfpDMIDiagTxPowerOverLowAlarm 1.3.6.1.4.1.6296.0.428
This trap indicates the TxPower of sfp is over the low threshold.(Alarm)
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfpDMIDiagTxPowerOverHighWarn 1.3.6.1.4.1.6296.0.429
This trap indicates the TxPower of sfp is over the high threshold.(Warn)
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfpDMIDiagTxPowerUnderHighWarn 1.3.6.1.4.1.6296.0.430
This trap indicates the TxPower of sfp is under the high threshold.(Warn)
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfpDMIDiagTxPowerUnderLowWarn 1.3.6.1.4.1.6296.0.431
This trap indicates the TxPower of sfp is under the low threshold.(Warn)
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfpDMIDiagTxPowerOverLowWarn 1.3.6.1.4.1.6296.0.432
This trap indicates the TxPower of sfp is over the low threshold.(Warn)
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfpDMIDiagRxPowerOverHighAlarm 1.3.6.1.4.1.6296.0.433
This trap indicates the RxPower of sfp is over the high threshold.(Alarm)
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfpDMIDiagRxPowerUnderHighAlarm 1.3.6.1.4.1.6296.0.434
This trap indicates the RxPower of sfp is under the high threshold.(Alarm)
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfpDMIDiagRxPowerUnderLowAlarm 1.3.6.1.4.1.6296.0.435
This trap indicates the RxPower of sfp is under the low threshold.(Alarm)
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfpDMIDiagRxPowerOverLowAlarm 1.3.6.1.4.1.6296.0.436
This trap indicates the RxPower of sfp is over the low threshold.(Alarm)
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfpDMIDiagRxPowerOverHighWarn 1.3.6.1.4.1.6296.0.437
This trap indicates the RxPower of sfp is over the high threshold.(Warn)
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfpDMIDiagRxPowerUnderHighWarn 1.3.6.1.4.1.6296.0.438
This trap indicates the RxPower of sfp is under the high threshold.(Warn)
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfpDMIDiagRxPowerUnderLowWarn 1.3.6.1.4.1.6296.0.439
This trap indicates the RxPower of sfp is under the low threshold.(Warn)
Status: current Access: not-accessible
NOTIFICATION-TYPE    

sfpDMIDiagRxPowerOverLowWarn 1.3.6.1.4.1.6296.0.440
This trap indicates the RxPower of sfp is over the low threshold.(Warn)
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuOnuServiceOpModeAlarm 1.3.6.1.4.1.6296.0.441
GPON ONU service operational mode alarm.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuOnuServiceOpModeAlarmOff 1.3.6.1.4.1.6296.0.442
GPON ONU service operational mode cleared alarm.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

systemTemperPowerCutOff 1.3.6.1.4.1.6296.0.443
This trap indicates the system temperature power cut off
Status: current Access: not-accessible
NOTIFICATION-TYPE    

systemTemperPowerCutoffCleared 1.3.6.1.4.1.6296.0.444
This trap indicates the system temperature power cut off trap is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

slotTemperPowerCutOff 1.3.6.1.4.1.6296.0.445
This trap indicates the slot temperature power cut off
Status: current Access: not-accessible
NOTIFICATION-TYPE    

slotTemperPowerCutOffCleared 1.3.6.1.4.1.6296.0.446
This trap indicates the slot temperature power cut off is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

gponOnuAuthErrorReasonUpdated 1.3.6.1.4.1.6296.0.461
This trap indicates GPON ONU authentication error reason is updated
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponRegErr 1.3.6.1.4.1.6296.0.501
This trap indicates the pon registration is not ok
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponBadEncryptionKey 1.3.6.1.4.1.6296.0.502
This trap indicates the pon encryption key is bad
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponLloidMismatch 1.3.6.1.4.1.6296.0.503
This trap indicates the pon LLOID is mismatched
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponTooManyOnu 1.3.6.1.4.1.6296.0.504
This trap indicates the pon has too many of ONU
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponDyingGasp 1.3.6.1.4.1.6296.0.505
This trap indicates the pon dying GASP
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponRegister 1.3.6.1.4.1.6296.0.506
This trap indicates the pon is registered
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponDeregister 1.3.6.1.4.1.6296.0.507
This trap indicates the pon is deregistered
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponLastOnuDeregister 1.3.6.1.4.1.6296.0.508
This trap indicates the last ONU is deregistered
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponCableDown 1.3.6.1.4.1.6296.0.509
This trap indicates the pon cable is down
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponCableDownRecover 1.3.6.1.4.1.6296.0.510
This trap indicates the pon cable down is recovered
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponFirstRegistration 1.3.6.1.4.1.6296.0.511
This trap indicates the first pon registration
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOntLinkUp 1.3.6.1.4.1.6296.0.512
This trap indicates the ont link up
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOltOnuDown 1.3.6.1.4.1.6296.0.513
This trap indicates the Onu down
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponHealthCheckErr 1.3.6.1.4.1.6296.0.514
This trap indicates the pon health check error
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponRegisterModeChange 1.3.6.1.4.1.6296.0.515
This trap indicates the pon register mode is changed
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOpticSignalErr 1.3.6.1.4.1.6296.0.516
This trap indicates the pon optic signal error
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOpticSignalErrRecover 1.3.6.1.4.1.6296.0.517
This trap indicates the pon optic signal error is recovered
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOverVolSigErr 1.3.6.1.4.1.6296.0.518
This trap indicates the pon over volatage signal error
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOverVolSigErrRecover 1.3.6.1.4.1.6296.0.519
This trap indicates the pon over volatage signal error is recovered
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuRssiInfoErr 1.3.6.1.4.1.6296.0.520
This trap indicates the Onu RSSI information error
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuRssiInfoErrCleared 1.3.6.1.4.1.6296.0.521
This trap indicates the Onu RSSI information error is cleard
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuCrcUpAlarmErr 1.3.6.1.4.1.6296.0.522
This trap indicates the ONU CRC up alarm error
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuCrcUpAlarmErrCleared 1.3.6.1.4.1.6296.0.523
This trap indicates the ONU CRC up alarm error is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuCrcDownAlarmErr 1.3.6.1.4.1.6296.0.524
This trap indicates the ONU CRC down alarm error
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuCrcDownAlarmErrCleared 1.3.6.1.4.1.6296.0.525
This trap indicates the ONU CRC down alarm error is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuTooFrequentlyRegErr 1.3.6.1.4.1.6296.0.526
This trap indicates the ONU is registered too frequently.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuTooFrequentlyRegErrCleared 1.3.6.1.4.1.6296.0.527
This trap indicates the ONU registration frequently error is cleared.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuOpticPowerAlarmErr 1.3.6.1.4.1.6296.0.528
This trap indicates the pon ONU optic power alarm error
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuOpticPowerAlarmErrCleared 1.3.6.1.4.1.6296.0.529
This trap indicates the pon ONU optic power alarm error is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuDcVoltageAlarmErr 1.3.6.1.4.1.6296.0.530
This trap indicates the pon ONU DC voltage alarm error
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuDcVoltageAlarmErrCleared 1.3.6.1.4.1.6296.0.531
This trap indicates the pon ONU DC voltage alarm error is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuLoopingAlarmErr 1.3.6.1.4.1.6296.0.532
This trap indicates the pon ONU looping alarm error
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuLoopingAlarmErrCleared 1.3.6.1.4.1.6296.0.533
This trap indicates the pon ONU looping alarm error is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponDetectRogueOnu 1.3.6.1.4.1.6296.0.534
This trap indicates the Rogue ONU detection.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponDetectRogueOnuCleared 1.3.6.1.4.1.6296.0.535
This trap indicates the Rogue ONU detection is cleared.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponDetectRogueOnuPowerOff 1.3.6.1.4.1.6296.0.536
This trap indicates the Rogue ONU power off is detected.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponDetectRogueOnuDeregisterSuccess 1.3.6.1.4.1.6296.0.537
This trap indicates the Rogue ONU deregister success is detected
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponDectectRogueOnuFoundFailed 1.3.6.1.4.1.6296.0.538
This trap indicates the Rogue ONU found fail is detected.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponDectectRogueOnuTurn 1.3.6.1.4.1.6296.0.539
This trap indicates the Rogue ONU turn is detected.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOltStandbyRxpowerOverHigh 1.3.6.1.4.1.6296.0.540
This trap indicates the Olt standby RX power is over high threshold
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOltStandbyRxpowerUnderLow 1.3.6.1.4.1.6296.0.541
This trap indicates the Olt standby RX power is under low threshold
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOltRedundancyPortDown 1.3.6.1.4.1.6296.0.542
This trap indicates the Olt redundancy port is down
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOltRedundancyRxpower 1.3.6.1.4.1.6296.0.543
This trap indicates the Olt redundancy RXpower
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuBcastStormLlidUpErr 1.3.6.1.4.1.6296.0.544
This trap indicates the broadcast storm llid up error
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuBcastStormLlidUpErrCleared 1.3.6.1.4.1.6296.0.545
This trap indicates the broadcast storm llid up error is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuBcastStormLlidDownErr 1.3.6.1.4.1.6296.0.546
This trap indicates the broadcast storm llid down error
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuBcastStormLlidDownErrCleared 1.3.6.1.4.1.6296.0.547
This trap indicates the broadcast storm llid down error is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuBcastStormUniUpErr 1.3.6.1.4.1.6296.0.548
This trap indicates the broadcast storm UNI up error
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuBcastStormUniUpErrCleared 1.3.6.1.4.1.6296.0.549
This trap indicates the broadcast storm Uni up error is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuReset 1.3.6.1.4.1.6296.0.550
This trap indicates Pon ONU reset
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuLifLcErrAlarmErr 1.3.6.1.4.1.6296.0.551
This trap indicates Pon ONU LIF Error
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuLifLcErrAlarmErrCleared 1.3.6.1.4.1.6296.0.552
This trap indicates Pon ONU LIF Error is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOltResetPonMac 1.3.6.1.4.1.6296.0.561
This trap indicates Pon OLT MAC reset
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOltRedSwitchover 1.3.6.1.4.1.6296.0.581
This trap indicates the OLT redundancy switchover
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOltRedGroupCreated 1.3.6.1.4.1.6296.0.582
This trap indicates the OLT redundancy group is created
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOltRedGroupDeleted 1.3.6.1.4.1.6296.0.583
This trap indicates the OLT redundancy group is deleted
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOltRedTriggerChanged 1.3.6.1.4.1.6296.0.584
This trap indicates the OLT redundancy trigger is changed
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOltRedDbResyncChanged 1.3.6.1.4.1.6296.0.585
This trap indicates the OLT redundancy DB resync is changed
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOltRedDbSyncChecked 1.3.6.1.4.1.6296.0.586
This trap indicates the OLT redundancy DB sync is checked
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuRssiWarn 1.3.6.1.4.1.6296.0.601
This trap indicates the ONU RSSI warning
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuRssiWarnCleared 1.3.6.1.4.1.6296.0.602
This trap indicates the ONU RSSI warning is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuRssiAlarm 1.3.6.1.4.1.6296.0.603
This trap indicates the ONU RSSI alarm
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuRssiAlarmCleared 1.3.6.1.4.1.6296.0.604
This trap indicates the ONU RSSI alarm is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuRxpowerWarn 1.3.6.1.4.1.6296.0.605
This trap indicates the ONU RX-power warning
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuRxpowerWarnCleared 1.3.6.1.4.1.6296.0.606
This trap indicates the ONU RX-power warning is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuRxpowerAlarm 1.3.6.1.4.1.6296.0.607
This trap indicates the ONU RX-power alarm
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuRxpowerAlarmCleared 1.3.6.1.4.1.6296.0.608
This trap indicates the ONU RX-power alarm is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponMacTableOverFlow 1.3.6.1.4.1.6296.0.609
This trap indicates the Mac table is over Max entry.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponMacTableOverFlowCleared 1.3.6.1.4.1.6296.0.610
This trap indicates the Mac over max entry is cleared.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

fiberLengthChangedWarningAlarm 1.3.6.1.4.1.6296.0.611
This trap indicates the fiber length is changed
Status: current Access: not-accessible
NOTIFICATION-TYPE    

fiberLengthChangedWarningAlarmCleared 1.3.6.1.4.1.6296.0.612
This trap indicates the fiber length trap is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuFrameReplicationAlarm 1.3.6.1.4.1.6296.0.613
This trap indicates the frame is replicated.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuFrameReplicationAlarmCleared 1.3.6.1.4.1.6296.0.614
This trap indicates the frame is replicated.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuRxpowerWarnOverHigh 1.3.6.1.4.1.6296.0.615
This trap indicates the ONU RX-power high over warning
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuRxpowerWarnOverHighCleared 1.3.6.1.4.1.6296.0.616
This trap indicates the ONU RX-power high over warning is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuRxpowerWarnUnderLow 1.3.6.1.4.1.6296.0.617
This trap indicates the ONU RX-power low under warning
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuRxpowerWarnUnderLowCleared 1.3.6.1.4.1.6296.0.618
This trap indicates the ONU RX-power low under warning is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuRxpowerAlarmOverHigh 1.3.6.1.4.1.6296.0.619
This trap indicates the ONU RX-power high over alarm
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuRxpowerAlarmOverHighCleared 1.3.6.1.4.1.6296.0.620
This trap indicates the ONU RX-power high over alarm is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuRxpowerAlarmUnderLow 1.3.6.1.4.1.6296.0.621
This trap indicates the ONU RX-power low under alarm
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuRxpowerAlarmUnderLowCleared 1.3.6.1.4.1.6296.0.622
This trap indicates the ONU RX-power low under alarm is cleared
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuUniLinkDown 1.3.6.1.4.1.6296.0.623
This trap indicates the Onu Uni link is down.
Status: current Access: not-accessible
NOTIFICATION-TYPE    

ponOnuUniLinkUp 1.3.6.1.4.1.6296.0.624
This trap indicates the Onu Uni link is up.
Status: current Access: not-accessible
NOTIFICATION-TYPE