DELL-RAC-MIB

File: DELL-RAC-MIB.mib (161404 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC-1215
RFC1213-MIB

Imported symbols

enterprises TimeTicks OBJECT-TYPE
TRAP-TYPE DisplayString

Defined Types

DellString  
DisplayString Size(0..1023)    

DellRacType  
INTEGER other(1), unknown(2), dracIII(3), era(4), drac4(5), drac5(6), drac5MC(7), cmc(8), idrac(9), vrtxCMC(18), fx2CMC(19)    

DellStatus  
INTEGER other(1), unknown(2), ok(3), nonCritical(4), critical(5), nonRecoverable(6)    

DellPowerReading  
DisplayString Size(0..32)    

DellCMCPowerIndexRange  
INTEGER 1..1    

DellCMCPSUIndexRange  
INTEGER 1..6    

DellCMCPSUCapable  
INTEGER absent(1), none(2), basic(3)    

DellTemperatureReading  
INTEGER    

DellTimestamp  
DisplayString Size(26)    

DellCMCServerIndexRange  
INTEGER 1..32    

DellCMCServerCapable  
INTEGER absent(1), none(2), basic(3), off(4)    

DrsCMCPowerTableEntry  
SEQUENCE    
  drsChassisIndex DellCMCPowerIndexRange
  drsPotentialPower DellPowerReading
  drsIdlePower DellPowerReading
  drsMaxPowerSpecification DellPowerReading
  drsPowerSurplus DellPowerReading
  drsKWhCumulative DellPowerReading
  drsKWhCumulativeTime DellTimestamp
  drsWattsPeakUsage DellPowerReading
  drsWattsPeakTime DellTimestamp
  drsWattsMinUsage DellPowerReading
  drsWattsMinTime DellTimestamp
  drsWattsResetTime DellTimestamp
  drsWattsReading DellPowerReading
  drsAmpsReading DellPowerReading

DrsCMCPSUTableEntry  
SEQUENCE    
  drsPSUChassisIndex DellCMCPowerIndexRange
  drsPSUIndex DellCMCPSUIndexRange
  drsPSULocation DellString
  drsPSUMonitoringCapable DellCMCPSUCapable
  drsPSUVoltsReading DellPowerReading
  drsPSUAmpsReading DellPowerReading
  drsPSUWattsReading DellPowerReading

DrsCMCServerTableEntry  
SEQUENCE    
  drsServerIndex DellCMCServerIndexRange
  drsServerMonitoringCapable DellCMCServerCapable
  drsServerServiceTag DellString
  drsServerSlotName DellString
  drsServerSlotNumber DellString
  drsServerNodeID DellString

Defined Values

dell 1.3.6.1.4.1.674
OBJECT IDENTIFIER    

server3 1.3.6.1.4.1.674.10892
OBJECT IDENTIFIER    

drsOutofBandGroup 1.3.6.1.4.1.674.10892.2
OBJECT IDENTIFIER    

drsInformationGroup 1.3.6.1.4.1.674.10892.2.1
OBJECT IDENTIFIER    

drsProductInfoGroup 1.3.6.1.4.1.674.10892.2.1.1
OBJECT IDENTIFIER    

drsFirmwareGroup 1.3.6.1.4.1.674.10892.2.1.2
OBJECT IDENTIFIER    

drsStatusGroup 1.3.6.1.4.1.674.10892.2.2
OBJECT IDENTIFIER    

drsChassisStatusGroup 1.3.6.1.4.1.674.10892.2.3
OBJECT IDENTIFIER    

drsStatusNowGroup 1.3.6.1.4.1.674.10892.2.3.1
OBJECT IDENTIFIER    

drsStatusPrevGroup 1.3.6.1.4.1.674.10892.2.3.2
OBJECT IDENTIFIER    

drsStatusChangeGroup 1.3.6.1.4.1.674.10892.2.3.3
OBJECT IDENTIFIER    

drsChassisPowerGroup 1.3.6.1.4.1.674.10892.2.4
OBJECT IDENTIFIER    

drsChassisServerGroup 1.3.6.1.4.1.674.10892.2.5
OBJECT IDENTIFIER    

drsCMCAlertGroup 1.3.6.1.4.1.674.10892.2.20
OBJECT IDENTIFIER    

drsChassisAlertVariables 1.3.6.1.4.1.674.10892.2.20.10
OBJECT IDENTIFIER    

drsCMCAlert2Group 1.3.6.1.4.1.674.10892.2.21
OBJECT IDENTIFIER    

drsChassisAlert2Variables 1.3.6.1.4.1.674.10892.2.21.10
OBJECT IDENTIFIER    

drsAlertGroup 1.3.6.1.4.1.674.10892.2.5000
OBJECT IDENTIFIER    

drsAlertVariables 1.3.6.1.4.1.674.10892.2.5000.10
OBJECT IDENTIFIER    

drsProductName 1.3.6.1.4.1.674.10892.2.1.1.1
0001.0001.0001 This attribute defines the product name of a chassis management controller.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

drsProductShortName 1.3.6.1.4.1.674.10892.2.1.1.2
0001.0001.0002 This attribute defines the short product name of a chassis management controller.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

drsProductDescription 1.3.6.1.4.1.674.10892.2.1.1.3
0001.0001.0003 This attribute defines the product description of a chassis management controller.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

drsProductManufacturer 1.3.6.1.4.1.674.10892.2.1.1.4
0001.0001.0004 This attribute defines the product manufacturer of a chassis management controller.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

drsProductVersion 1.3.6.1.4.1.674.10892.2.1.1.5
0001.0001.0005 This attribute defines the product version of a chassis management controller.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

drsChassisServiceTag 1.3.6.1.4.1.674.10892.2.1.1.6
0001.0001.0007 This attribute defines the Service Tag of the chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

drsProductURL 1.3.6.1.4.1.674.10892.2.1.1.7
0001.0001.0006 This attribute defines the out-of-band UI URL of a chassis management controller.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

drsProductChassisAssetTag 1.3.6.1.4.1.674.10892.2.1.1.8
0001.0001.0008 This attribute defines the Asset Tag of the chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

drsProductChassisLocation 1.3.6.1.4.1.674.10892.2.1.1.9
0001.0001.0009 This attribute defines the location of the chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

drsProductChassisName 1.3.6.1.4.1.674.10892.2.1.1.10
0001.0001.0010 This attribute defines the name of the chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

drsSystemServiceTag 1.3.6.1.4.1.674.10892.2.1.1.11
0001.0001.0011 This attribute defines the service tag of a system.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

drsProductSystemAssetTag 1.3.6.1.4.1.674.10892.2.1.1.12
0001.0001.0012 This attribute defines the asset tag of a system.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

drsProductSystemSlot 1.3.6.1.4.1.674.10892.2.1.1.13
0001.0001.0013 This attribute defines the slot number of a CMC.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

drsProductType 1.3.6.1.4.1.674.10892.2.1.1.14
0001.0001.0014 This attribute defines type of a remote access card
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellRacType  

drsProductChassisDataCenter 1.3.6.1.4.1.674.10892.2.1.1.15
0001.0001.0015 This attribute defines the Data Center locator of the chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

drsProductChassisAisle 1.3.6.1.4.1.674.10892.2.1.1.16
0001.0001.0016 This attribute defines the Aisle locator of the chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

drsProductChassisRack 1.3.6.1.4.1.674.10892.2.1.1.17
0001.0001.0017 This attribute defines the Rack locator of the chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

drsProductChassisRackSlot 1.3.6.1.4.1.674.10892.2.1.1.18
0001.0001.0018 This attribute defines the Rack Slot locator of the chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

drsProductChassisModel 1.3.6.1.4.1.674.10892.2.1.1.19
0001.0001.0019 This attribute defines the Model of the chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

drsProductChassisExpressServiceCode 1.3.6.1.4.1.674.10892.2.1.1.20
0001.0001.0020 This attribute defines the Express Service Code of the chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

drsProductChassisSystemID 1.3.6.1.4.1.674.10892.2.1.1.21
0001.0001.0021 This attribute defines the System ID of the chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

drsProductChassisSize 1.3.6.1.4.1.674.10892.2.1.1.22
0001.0001.0022 This attribute defines the size of the chassis in rack units (U). A U is a standard unit of measure for the height of a rack or rack-mountable component.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

drsFirmwareVersion 1.3.6.1.4.1.674.10892.2.1.2.1
0001.0002.0001 This attribute defines the firmware version of chassis management controller 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

drsiKVMFirmwareVersion 1.3.6.1.4.1.674.10892.2.1.2.2
0001.0002.0002 This attribute defines the firmware version of the iKVM.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

drsFirmwareVersion2 1.3.6.1.4.1.674.10892.2.1.2.3
0001.0002.0003 This attribute defines the firmware version of chassis management controller 2.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

drsGlobalSystemStatus 1.3.6.1.4.1.674.10892.2.2.1
0002.0001.0001 This attribute defines the overall chassis status being monitored by the chassis management card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellStatus  

drsGlobalCurrStatus 1.3.6.1.4.1.674.10892.2.3.1.1
0003.0001.0001 This attribute defines the overall chassis status being monitored by the chassis management card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellStatus  

drsIOMCurrStatus 1.3.6.1.4.1.674.10892.2.3.1.2
0003.0001.0002 This attribute defines the IOM subsystem status being monitored by the chassis management card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellStatus  

drsKVMCurrStatus 1.3.6.1.4.1.674.10892.2.3.1.3
0003.0001.0003 This attribute defines the iKVM subsystem health status being monitored by the chassis management card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellStatus  

drsRedCurrStatus 1.3.6.1.4.1.674.10892.2.3.1.4
0003.0001.0004 This attribute defines the Redundancy status being monitored by the chassis management card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellStatus  

drsPowerCurrStatus 1.3.6.1.4.1.674.10892.2.3.1.5
0003.0001.0005 This attribute defines the power subsystem health status being monitored by the chassis management card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellStatus  

drsFanCurrStatus 1.3.6.1.4.1.674.10892.2.3.1.6
0003.0001.0006 This attribute defines the Fan subsystem health status being monitored by the chassis management card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellStatus  

drsBladeCurrStatus 1.3.6.1.4.1.674.10892.2.3.1.7
0003.0001.0007 This attribute defines the Blade subsystem health status being monitored by the chassis management card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellStatus  

drsTempCurrStatus 1.3.6.1.4.1.674.10892.2.3.1.8
0003.0001.0008 This attribute defines the Temp Sensor subsystem health status being monitored by the chassis management card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellStatus  

drsCMCCurrStatus 1.3.6.1.4.1.674.10892.2.3.1.9
0003.0001.0009 This attribute defines the CMC health status being monitored by the chassis management card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellStatus  

drsChassisFrontPanelAmbientTemperature 1.3.6.1.4.1.674.10892.2.3.1.10
0003.0001.0010 This attribute defines the ambient temperature reading (in degrees Celsius) for the chassis front panel controller.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellTemperatureReading  

drsCMCAmbientTemperature 1.3.6.1.4.1.674.10892.2.3.1.11
0003.0001.0011 This attribute defines the ambient temperature reading (in degrees Celsius) for the chassis management card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellTemperatureReading  

drsCMCProcessorTemperature 1.3.6.1.4.1.674.10892.2.3.1.12
0003.0001.0012 This attribute defines the temperature reading (in degrees Celsius) for the chassis management card processor.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellTemperatureReading  

drsGlobalPrevStatus 1.3.6.1.4.1.674.10892.2.3.2.1
0003.0002.0001 This attribute defines the previous chassis status recorded by the chassis management card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellStatus  

drsIOMPrevStatus 1.3.6.1.4.1.674.10892.2.3.2.2
0003.0002.0002 This attribute defines the previous IOM subsystem status recorded by the chassis management card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellStatus  

drsKVMPrevStatus 1.3.6.1.4.1.674.10892.2.3.2.3
0003.0002.0003 This attribute defines the previous iKVM subsystem health status recorded by the chassis management card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellStatus  

drsRedPrevStatus 1.3.6.1.4.1.674.10892.2.3.2.4
0003.0002.0004 This attribute defines the previous Redundancy status recorded by the chassis management card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellStatus  

drsPowerPrevStatus 1.3.6.1.4.1.674.10892.2.3.2.5
0003.0002.0005 This attribute defines the previous power subsystem health status recorded by the chassis management card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellStatus  

drsFanPrevStatus 1.3.6.1.4.1.674.10892.2.3.2.6
0003.0002.0006 This attribute defines the previous Fan health status being monitored by the chassis management card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellStatus  

drsBladePrevStatus 1.3.6.1.4.1.674.10892.2.3.2.7
0003.0002.0007 This attribute defines the previous Blade subsystem health status recorded by the chassis management card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellStatus  

drsTempPrevStatus 1.3.6.1.4.1.674.10892.2.3.2.8
0003.0001.0008 This attribute defines the Temp Sensor health status being monitored by the chassis management card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellStatus  

drsCMCPrevStatus 1.3.6.1.4.1.674.10892.2.3.2.9
0003.0001.0009 This attribute defines the CMC health status being monitored by the chassis management card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellStatus  

drsGlobalChangeTime 1.3.6.1.4.1.674.10892.2.3.3.1
0003.0003.0001 This attribute defines the timestamp of the most recent global status change.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

drsIOMChangeTime 1.3.6.1.4.1.674.10892.2.3.3.2
0003.0003.0002 This attribute defines the timestamp of the most recent IOM status change.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

drsKVMChangeTime 1.3.6.1.4.1.674.10892.2.3.3.3
0003.0003.0003 This attribute defines the timestamp of the most recent iKVM status change.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

drsRedChangeTime 1.3.6.1.4.1.674.10892.2.3.3.4
0003.0003.0004 This attribute defines the timestamp of the most recent Redundancy status change.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

drsPowerChangeTime 1.3.6.1.4.1.674.10892.2.3.3.5
0003.0003.0005 This attribute defines the timestamp of the most recent power health status change.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

drsFanChangeTime 1.3.6.1.4.1.674.10892.2.3.3.6
0003.0003.0006 This attribute defines the timestamp of the most recent Fan health status change.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

drsBladeChangeTime 1.3.6.1.4.1.674.10892.2.3.3.7
0003.0003.0007 This attribute defines the timestamp of the most recent Blade health status change.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

drsTempChangeTime 1.3.6.1.4.1.674.10892.2.3.3.8
0003.0003.0008 This attribute defines the timestamp of the most recent Temp Sensor health status change.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

drsCMCChangeTime 1.3.6.1.4.1.674.10892.2.3.3.9
0003.0003.0009 This attribute defines the timestamp of the most recent CMC health status change.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

drsCMCPowerTable 1.3.6.1.4.1.674.10892.2.4.1
0004.0001 This object defines the CMC power table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DrsCMCPowerTableEntry

drsCMCPowerTableEntry 1.3.6.1.4.1.674.10892.2.4.1.1
0004.0001.0001 This object defines the CMC power table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DrsCMCPowerTableEntry  

drsCMCPSUTable 1.3.6.1.4.1.674.10892.2.4.2
0004.0002 This object defines the CMC PSU table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DrsCMCPSUTableEntry

drsCMCPSUTableEntry 1.3.6.1.4.1.674.10892.2.4.2.1
0004.0002.0001 This object defines the CMC PSU table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DrsCMCPSUTableEntry  

drsChassisIndex 1.3.6.1.4.1.674.10892.2.4.1.1.1
0004.0001.0001.0001 This attribute defines the index (one-based) of the associated chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellCMCPowerIndexRange  

drsPotentialPower 1.3.6.1.4.1.674.10892.2.4.1.1.2
0004.0001.0001.0002 This attribute defines the power (in Watts) required by the chassis infrastructure, plus the sum of the maximum power requirements for all currently powered-on servers.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellPowerReading  

drsIdlePower 1.3.6.1.4.1.674.10892.2.4.1.1.3
0004.0001.0001.0003 This attribute defines the power (in Watts) required by the chassis infrastructure, plus the sum of the minimum power requirements for all currently powered-on servers.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellPowerReading  

drsMaxPowerSpecification 1.3.6.1.4.1.674.10892.2.4.1.1.4
0004.0001.0001.0004 This attribute defines the power limit (in Watts) at which server throttling will take place.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellPowerReading  

drsPowerSurplus 1.3.6.1.4.1.674.10892.2.4.1.1.5
0004.0001.0001.0005 This attribute defines the power surplus (in Watts) remaining above the drsPotentialPower reading.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellPowerReading  

drsKWhCumulative 1.3.6.1.4.1.674.10892.2.4.1.1.6
0004.0001.0001.0006 This attribute defines the cumulative chassis power usage (in KWh) since last reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellPowerReading  

drsKWhCumulativeTime 1.3.6.1.4.1.674.10892.2.4.1.1.7
0004.0001.0001.0007 This attribute defines the timestamp of the most recent chassis power accumulator reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellTimestamp  

drsWattsPeakUsage 1.3.6.1.4.1.674.10892.2.4.1.1.8
0004.0001.0001.0008 This attribute defines the chassis peak power usage (in Watts) since last reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellPowerReading  

drsWattsPeakTime 1.3.6.1.4.1.674.10892.2.4.1.1.9
0004.0001.0001.0009 This attribute defines the timestamp of the most recent chassis peak power usage.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellTimestamp  

drsWattsMinUsage 1.3.6.1.4.1.674.10892.2.4.1.1.10
0004.0001.0001.0010 This attribute defines the chassis mimimum power usage (in Watts) since last reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellPowerReading  

drsWattsMinTime 1.3.6.1.4.1.674.10892.2.4.1.1.11
0004.0001.0001.0011 This attribute defines the timestamp of the most recent chassis minimum power usage.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellTimestamp  

drsWattsResetTime 1.3.6.1.4.1.674.10892.2.4.1.1.12
0004.0001.0001.0012 This attribute defines the timestamp of the most recent reset of the chassis min/peak Watts readings.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellTimestamp  

drsWattsReading 1.3.6.1.4.1.674.10892.2.4.1.1.13
0004.0001.0001.0013 This attribute defines the instantaneous chassis power usage (in Watts).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellPowerReading  

drsAmpsReading 1.3.6.1.4.1.674.10892.2.4.1.1.14
0004.0001.0001.0014 This attribute defines the instantaneous chassis current usage (in Watts).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellPowerReading  

drsPSUChassisIndex 1.3.6.1.4.1.674.10892.2.4.2.1.1
0004.0002.0001.0001 This attribute defines the index (one-based) of the associated chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellCMCPowerIndexRange  

drsPSUIndex 1.3.6.1.4.1.674.10892.2.4.2.1.2
0004.0002.0001.0002 This attribute defines the index (one-based) of the associated CMC PSU.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellCMCPSUIndexRange  

drsPSULocation 1.3.6.1.4.1.674.10892.2.4.2.1.3
0004.0002.0001.0003 This attribute defines the location of the CMC PSU.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

drsPSUMonitoringCapable 1.3.6.1.4.1.674.10892.2.4.2.1.4
0004.0002.0001.0004 This attribute defines the PSU Monitoring capabilities, or the absence of a PSU in this location.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellCMCPSUCapable  

drsPSUVoltsReading 1.3.6.1.4.1.674.10892.2.4.2.1.5
0004.0002.0001.0005 This attribute defines the instantaneous PSU Voltage reading.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellPowerReading  

drsPSUAmpsReading 1.3.6.1.4.1.674.10892.2.4.2.1.6
0004.0002.0001.0006 This attribute defines the instantaneous PSU Current reading.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellPowerReading  

drsPSUWattsReading 1.3.6.1.4.1.674.10892.2.4.2.1.7
0004.0002.0001.0007 This attribute defines the instantaneous PSU Wattage reading.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellPowerReading  

drsCMCServerTable 1.3.6.1.4.1.674.10892.2.5.1
0005.0001 This object defines the CMC server table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DrsCMCServerTableEntry

drsCMCServerTableEntry 1.3.6.1.4.1.674.10892.2.5.1.1
0005.0001.0001 This object defines the CMC server table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DrsCMCServerTableEntry  

drsServerIndex 1.3.6.1.4.1.674.10892.2.5.1.1.1
0005.0001.0001.0001 This attribute defines the index (one-based) of the associated CMC server.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellCMCServerIndexRange  

drsServerMonitoringCapable 1.3.6.1.4.1.674.10892.2.5.1.1.2
0005.0001.0001.0002 This attribute defines the server monitoring capabilities, or the absence of a server in this location.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellCMCServerCapable  

drsServerServiceTag 1.3.6.1.4.1.674.10892.2.5.1.1.3
0005.0001.0001.0003 This attribute defines the Service Tag of the CMC server.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

drsServerSlotName 1.3.6.1.4.1.674.10892.2.5.1.1.4
0005.0001.0001.0004 This attribute defines the Slot Name of the CMC server.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

drsServerSlotNumber 1.3.6.1.4.1.674.10892.2.5.1.1.5
0005.0001.0001.0005 This attribute defines the Chassis Slot Number of the CMC server.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

drsServerNodeID 1.3.6.1.4.1.674.10892.2.5.1.1.6
0005.0001.0001.0006 This attribute defines the Node ID of the CMC server. The Node ID provides a unique identifier for the server.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

drsCASubSystem 1.3.6.1.4.1.674.10892.2.20.10.1
0020.0010.0001 This attribute defines the Sub-System Name of the CMC Alert
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

drsCASSCurrStatus 1.3.6.1.4.1.674.10892.2.20.10.2
0020.0010.0002 This attribute defines the Current Status of the Alerting Sub-System
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellStatus  

drsCASSPrevStatus 1.3.6.1.4.1.674.10892.2.20.10.3
0020.0010.0003 This attribute defines the Previous Status of the Alerting Sub-System
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellStatus  

drsCASSChangeTime 1.3.6.1.4.1.674.10892.2.20.10.4
0020.0010.0004 This attribute defines the Timestamp of Most Recent Change of the Alerting Sub-System
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

drsCAMessage 1.3.6.1.4.1.674.10892.2.20.10.5
0020.0010.0005 This attribute defines the CSSD message of the CMC Alert
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

alertCMCTestTrap 2000
The CMC has generated a test trap
TRAP-TYPE    

alertCMCNormalTrap 2002
The CMC reported a return-to-normal or informational event.
TRAP-TYPE    

alertCMCWarningTrap 2003
The CMC reported a warning event.
TRAP-TYPE    

alertCMCCriticalTrap 2004
The CMC reported a critical event.
TRAP-TYPE    

alertCMCNonRecoverableTrap 2005
The CMC reported a catastrophic event.
TRAP-TYPE    

drsCA2MessageID 1.3.6.1.4.1.674.10892.2.21.10.1
Message ID of the alert.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

drsCA2Message 1.3.6.1.4.1.674.10892.2.21.10.2
Message describing the alert.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

drsCA2MessageArgs 1.3.6.1.4.1.674.10892.2.21.10.3
Concatenated set of strings representing any message arguments that were used to construct the alert message. Each message argument string is enclosed in double quotes, and there is a comma after the ending double quote of each message argument string, except the last one. Any double quotes found within a message argument string were preprocessed and changed to single quotes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

drsCA2AlertStatus 1.3.6.1.4.1.674.10892.2.21.10.4
Status of the alert.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellStatus  

drsCA2FQDD 1.3.6.1.4.1.674.10892.2.21.10.5
Fully qualified device descriptor of device causing the alert.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..512)  

alert2AmperageProbeNormal 2179
Current sensor reading is within range.
TRAP-TYPE    

alert2AmperageProbeWarning 2178
Current sensor has detected a warning value.
TRAP-TYPE    

alert2AmperageProbeFailure 2177
Current sensor has detected a failure value.
TRAP-TYPE    

alert2BatteryNormal 2227
Battery state has returned to normal; or battery presence had been detected.
TRAP-TYPE    

alert2BatteryWarning 2226
Battery is low.
TRAP-TYPE    

alert2BatteryFailure 2225
Battery has failed or battery is absent.
TRAP-TYPE    

alert2CableFailure 2393
Cable failure.
TRAP-TYPE    

alert2CMCWarning 2546
Chassis Management Controller detected a warning.
TRAP-TYPE    

alert2CMCFailure 2545
Chassis Management Controller detected an error.
TRAP-TYPE    

alert2FanInformation 2155
Fan information.
TRAP-TYPE    

alert2FanWarning 2154
Fan warning.
TRAP-TYPE    

alert2FanFailure 2153
Fan failure.
TRAP-TYPE    

alert2HardwareConfigurationInformation 2331
Hardware configuration information.
TRAP-TYPE    

alert2HardwareConfigurationWarning 2330
Hardware configuration warning.
TRAP-TYPE    

alert2HardwareConfigurationFailure 2329
Hardware configuration failure or critical event.
TRAP-TYPE    

alert2IOVirtualizationInformation 2555
IO Virtualization information.
TRAP-TYPE    

alert2IOVirtualizationWarning 2554
IO Virtualization warning.
TRAP-TYPE    

alert2IOVirtualizationFailure 2553
IO Virtualization failure or critical event.
TRAP-TYPE    

alert2LinkStatusInformation 2251
Link status information.
TRAP-TYPE    

alert2LinkStatusWarning 2250
Link status warning.
TRAP-TYPE    

alert2LinkStatusFailure 2249
Link status failure or critical event.
TRAP-TYPE    

alert2PCIDeviceInformation 2419
PCI device information.
TRAP-TYPE    

alert2PCIDeviceWarning 2418
PCI device warning.
TRAP-TYPE    

alert2PCIDeviceFailure 2417
PCI device failure or critical event.
TRAP-TYPE    

alert2PowerSupplyNormal 2187
Power supply has returned to normal.
TRAP-TYPE    

alert2PowerSupplyWarning 2186
Power supply has detected a warning.
TRAP-TYPE    

alert2PowerSupplyFailure 2185
Power supply has detected a failure.
TRAP-TYPE    

alert2PowerSupplyAbsent 2465
Power supply is absent.
TRAP-TYPE    

alert2PowerUsageInformation 2275
Power usage information.
TRAP-TYPE    

alert2PowerUsageWarning 2274
Power usage warning.
TRAP-TYPE    

alert2RedundancyInformation 2475
Redundancy information.
TRAP-TYPE    

alert2RedundancyDegraded 2474
Redundancy is degraded.
TRAP-TYPE    

alert2RedundancyLost 2473
Redundancy is lost.
TRAP-TYPE    

alert2SecurityInformation 2387
Security information.
TRAP-TYPE    

alert2SecurityWarning 2386
Security warning.
TRAP-TYPE    

alert2SecurityFailure 2385
Security failure or critical event.
TRAP-TYPE    

alert2SystemEventLogInformation 2379
System Event Log information.
TRAP-TYPE    

alert2SystemEventLogWarning 2378
System Event Log warning.
TRAP-TYPE    

alert2SystemEventLogFailure 2377
System Event Log failure or critical event.
TRAP-TYPE    

alert2SoftwareConfigurationInformation 2339
Software configuration information.
TRAP-TYPE    

alert2SoftwareConfigurationWarning 2338
Software configuration warning.
TRAP-TYPE    

alert2TemperatureProbeNormal 2163
Temperature sensor value is within range.
TRAP-TYPE    

alert2TemperatureProbeWarning 2162
Temperature sensor has detected a warning value.
TRAP-TYPE    

alert2TemperatureProbeFailure 2161
Temperature sensor has detected a failure value.
TRAP-TYPE    

alert2VoltageProbeNormal 2171
Voltage sensor reading is within range.
TRAP-TYPE    

alert2VoltageProbeWarning 2170
Voltage sensor has detected a warning value.
TRAP-TYPE    

alert2VoltageProbeFailure 2169
Voltage sensor has detected a failure value.
TRAP-TYPE    

alert2StorageBatteryInformation 4275
Storage Battery information.
TRAP-TYPE    

alert2StorageBatteryWarning 4274
Storage Battery warning.
TRAP-TYPE    

alert2StorageBatteryFailure 4273
Storage Battery failure.
TRAP-TYPE    

alert2StorageControllerInformation 4331
Storage Controller information.
TRAP-TYPE    

alert2StorageControllerWarning 4330
Storage Controller warning.
TRAP-TYPE    

alert2StorageControllerFailure 4329
Storage Controller failure.
TRAP-TYPE    

alert2StorageEnclosureInformation 4339
Storage Enclosure information.
TRAP-TYPE    

alert2StorageEnclosureWarning 4338
Storage Enclosure warning.
TRAP-TYPE    

alert2StorageEnclosureFailure 4337
Storage Enclosure failure.
TRAP-TYPE    

alert2StorageFanInformation 4203
Storage Fan information.
TRAP-TYPE    

alert2StorageFanWarning 4202
Storage Fan warning.
TRAP-TYPE    

alert2StorageFanFailure 4201
Storage Fan failure.
TRAP-TYPE    

alert2StoragePhysicalDiskInformation 4347
Storage Physical disk information.
TRAP-TYPE    

alert2StoragePhysicalDiskWarning 4346
Storage Physical disk warning.
TRAP-TYPE    

alert2StoragePhysicalDiskFailure 4345
Storage Physical disk failure.
TRAP-TYPE    

alert2StoragePowerSupplyInformation 4235
Storage Power supply information.
TRAP-TYPE    

alert2StoragePowerSupplyWarning 4234
Storage Power supply warning.
TRAP-TYPE    

alert2StoragePowerSupplyFailure 4233
Storage Power supply failure.
TRAP-TYPE    

alert2StorageManagementInformation 4179
Storage Management information. There is no global status change associated with this trap.
TRAP-TYPE    

alert2StorageManagementWarning 4178
Storage Management has detected a device independent warning condition. There is no global status change associated with this trap.
TRAP-TYPE    

alert2StorageManagementFailure 4177
Storage Management has detected a device independent error condition. There is no global status change associated with this trap.
TRAP-TYPE    

alert2StorageTemperatureProbeInformation 4211
Storage Temperature probe information.
TRAP-TYPE    

alert2StorageTemperatureProbeWarning 4210
Storage Temperature probe warning.
TRAP-TYPE    

alert2StorageTemperatureProbeFailure 4209
Storage Temperature probe failure.
TRAP-TYPE    

alert2StorageVirtualDiskInformation 4355
Storage Virtual disk information.
TRAP-TYPE    

alert2StorageVirtualDiskWarning 4354
Storage Virtual disk warning.
TRAP-TYPE    

alert2StorageVirtualDiskFailure 4353
Storage Virtual disk failure.
TRAP-TYPE    

alert2CMCAuditInformation 8691
Chassis Management Controller audit information.
TRAP-TYPE    

alert2CMCAuditWarning 8690
Chassis Management Controller audit warning.
TRAP-TYPE    

alert2CMCAuditFailure 8689
Chassis Management Controller audit failure or critical event.
TRAP-TYPE    

alert2IOVirtualizationAuditWarning 8698
IO Virtualization audit warning.
TRAP-TYPE    

alert2LicenseInformation 8515
License information.
TRAP-TYPE    

alert2LicenseWarning 8514
License warning.
TRAP-TYPE    

alert2LicenseFailure 8513
License failure.
TRAP-TYPE    

alert2PCIDeviceAuditWarning 8562
PCI device audit warning.
TRAP-TYPE    

alert2PowerSupplyAuditWarning 8330
Power Supply audit warning.
TRAP-TYPE    

alert2PowerSupplyAuditFailure 8329
Power Supply audit failure or critical event.
TRAP-TYPE    

alert2PowerUsageAuditWarning 8418
Power usage audit warning.
TRAP-TYPE    

alert2PowerUsageAuditFailure 8417
Power usage audit failure or critical event.
TRAP-TYPE    

alert2SoftwareChangeAuditFailure 8361
Software change audit failure or critical event.
TRAP-TYPE    

alert2IOVConfigurationInformation 10747
IO Virtualization configuration information.
TRAP-TYPE    

alert2IOVConfigurationWarning 10746
IO Virtualization configuration warning.
TRAP-TYPE    

alert2PCIDeviceConfigurationInformation 10611
PCI device configuration information.
TRAP-TYPE    

alert2CMCTestTrap 10395
Test trap generated by CMC in response to a user request.
TRAP-TYPE    

drsAlertSystem 1.3.6.1.4.1.674.10892.2.5000.10.1
5000.0010.0001 Name of the system generating the alert.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..255)  

drsAlertTableIndexOID 1.3.6.1.4.1.674.10892.2.5000.10.2
5000.0010.0002 0.0
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

drsAlertMessage 1.3.6.1.4.1.674.10892.2.5000.10.3
5000.0010.0003 Message describing the alert.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..1024)  

drsAlertCurrentStatus 1.3.6.1.4.1.674.10892.2.5000.10.4
5000.0010.0004 Current status of object causing the alert.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellStatus  

drsAlertPreviousStatus 1.3.6.1.4.1.674.10892.2.5000.10.5
5000.0010.0005 Previous status of object causing the alert.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellStatus  

drsAlertData 1.3.6.1.4.1.674.10892.2.5000.10.6
5000.0010.0006 Alert data.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..1024)  

alertDrscTestTrapEvent 1001
The RAC generated a test trap event in response to a user request.
TRAP-TYPE    

alertDrscAuthError 1002
The RAC Authentication Failures during a time period have Exceeded a Threshold.
TRAP-TYPE    

alertDrscLostESM 1003
The RAC cannot communicate with the baseboard management controller (ESM).
TRAP-TYPE    

alertDrscFoundESM 1004
The RAC is communicating normally with the baseboard management controller (ESM).
TRAP-TYPE    

alertDrscPowerOff 1005
The RAC has detected a System power state change to powered-off.
TRAP-TYPE    

alertDrscPowerOn 1006
The RAC has detected a system power state change to powered-on.
TRAP-TYPE    

alertDrscWatchdogExpired 1007
The RAC has detected that the system watchdog has expired indicating a system hang.
TRAP-TYPE    

alertDrscBattLow 1008
The RAC Battery charge is below 25% indicating that the battery may only be able to power the DRSC for 8-10 minutes.
TRAP-TYPE    

alertDrscTempNormal 1009
The RAC Temperature probe has retured to a normal value.
TRAP-TYPE    

alertDrscTempWarning 1010
The RAC Temperature probe has detected a Warning value.
TRAP-TYPE    

alertDrscTempCritical 1011
The RAC Temperature probe has detected a failure (or critical) value.
TRAP-TYPE    

alertDrscVoltNormal 1012
The RAC voltage has returned to a normal value.
TRAP-TYPE    

alertDrscVoltWarning 1013
The RAC voltage probe has detected a warning value.
TRAP-TYPE    

alertDrscVoltCritical 1014
The RAC voltage probe has detected a failure (or critical) value.
TRAP-TYPE    

alertDrscSELWarning 1015
The RAC has detected a new event in the System Event Log with Severity: Warning.
TRAP-TYPE    

alertDrscSELCritical 1016
The RAC has detected a new event in the System Event Log with Severity: Critical.
TRAP-TYPE    

alertDrscSEL80percentFull 1017
The RAC has detected that the System Event Log is 80% full.
TRAP-TYPE    

alertDrscSEL90percentFull 1018
The RAC has detected that the System Event Log is 90% full.
TRAP-TYPE    

alertDrscSEL100percentFull 1019
The RAC has detected that the System Event Log is 100% full.
TRAP-TYPE    

alertDrscSELNormal 1020
The RAC has detected a new event in the System Event Log with Severity: Normal.
TRAP-TYPE