DL-NEW-DSX1-MIB

File: DL-NEW-DSX1-MIB.mib (102174 bytes)

Imported modules

RFC1155-SMI RFC1213-MIB RFC-1212
RFC-1215

Imported symbols

enterprises IpAddress Counter
Gauge DisplayString OBJECT-TYPE
TRAP-TYPE

Defined Types

MacAddress  
OCTET STRING Size(6)    

Boolean  
INTEGER true(1), false(2)    

PortId  
INTEGER mainNet(1), aux(2), otherNet(3), reserved1(4), reserved2(5), reserved3(6), ethPort(7), commPort(8), int-clock(9), ext-clock(10), data1(11), data2(12), data3(13), data4(14), data5(15), data6(16), data7(17), data8(18), data9(19), data10(20), data11(21), data12(22), data13(23), data14(24), data15(25), data16(26), data17(27), data18(28), data19(29), data20(30), data21(31), data22(32), data23(33), data24(34), data25(35), data26(36), data27(37), data28(38), data29(39), data30(40), data31(41), data32(42), noPort(43)    

AlarmType  
INTEGER lostSignal(1), lostSync(2), detectedYellow(3), detectedAIS(4), detectedExternalAlarm(5), exceededBpvThreshold(6), exceededOofThreshold(7), exceededCrcThreshold(8), remoteAlarmBitSet(9), detectedPSfailure(10), detectedCntlCardMissing(11), lostDlcFdlLink(12), exceededIbCrcThreshold(13), lostDlcInbandLink(14), lmiSpoofing(15)    

TestType  
INTEGER noTest(1), selfTest(2), netLoopback(3), payloadLoopback(4), dteLoopback(5), loopUpRemote(6), loopDownRemote(7), sendQrwPattern(8), send1in8Pattern(9), send1in1Pattern(10), send1in3Pattern(11), send1in5Pattern(12), send2in3Pattern(14), send4in5Pattern(15), send3in24Pattern(16), sendAllOnePattern(17), sendAllZeroPattern(18), sendUser1Pattern(19), sendUser2Pattern(20), sendSmartJackSet(21), sendSmartJackReset(22), sendAPatternError(23), dteNetLoopback(24), reserved1(25), reserved2(26), reserved3(27), reserved4(28), reserved5(29), reserved6(30), lampTest(31)    

LoopCodeType  
INTEGER standard(1), alternate(2), v54(3), reserved1(4), reserved2(5), reserved3(6), disable(7)    

DlcDsx1TrapEnableEntry  
SEQUENCE    
  dlcDsx1TrapPortId PortId
  dlcDsx1BpvThresholdTrap INTEGER
  dlcDsx1OofThresholdTrap INTEGER
  dlcDsx1CrcThresholdTrap INTEGER
  dlcDsx1LossOfSignalTrapEnable Boolean
  dlcDsx1LossOfSyncTrapEnable Boolean
  dlcDsx1ReceiveAIStrapEnable Boolean
  dlcDsx1ReceiveYellowAlarmTrapEnable Boolean
  dlcDsx1ReceiveRemoteAlarmTrapEnable Boolean
  dlcDsx1PSfailureTrapEnable Boolean
  dlcDsx1CntlCrdMissingTrapEnable Boolean
  dlcDsx1FdlLinkTrapEnable Boolean
  dlcDsx1IbCrcThresholdTrap INTEGER
  dlcDsx1InbandLinkTrapEnable Boolean

DlcDataDteLossTrapEnableEntry  
SEQUENCE    
  dlcDataLossPortId PortId
  dlcDataLossEnable Boolean

DlcDsx1ConfigEntry  
SEQUENCE    
  dlcDsx1ConfigPortId PortId
  dlcDsx1Framing INTEGER
  dlcDsx1LineCode INTEGER
  dlcDsx1LineMatching INTEGER
  dlcDsx1DacsMode Boolean
  dlcDsx1UseDlcFdlProtocol Boolean
  dlcDsx1UseAnsiProtocol Boolean
  dlcDsx1Bit7Stuffing Boolean
  dlcDsx1InBandBit INTEGER

DlcDataDteConfigEntry  
SEQUENCE    
  dlcDataConfigPortId PortId
  dlcDataConfigEncoding INTEGER
  dlcDataConfigLoss INTEGER
  dlcDataConfigMode INTEGER
  dlcDataConfigFormat INTEGER
  dlcDataConfigTransmitTiming INTEGER

DlcMuxConfigEntry  
SEQUENCE    
  dlcMuxConfigBusId INTEGER
  dlcMuxConfigSlotNumber INTEGER
  dlcMuxConfigPortId PortId

UnitStatusItem  
INTEGER normal(1), noClock(2), testInProgress(4), sendKeepAlive(8), sendYellowAlarm(16), reserved1(32), reserved2(64), reserved3(128), reserved4(256), reserved5(512)    

PortStatusItem  
INTEGER normal(1), lossOfSignal(2), lossOfSync(3), yellowAlarmDetected(4), blueAlarmDetected(5), setCodeReceived(6), resetCodeReceived(7), excessiveErrorRate(8), localTest(9), eBitReceived(10), reserved1(11), reserved2(12), reserved3(13), reserved4(14)    

DlcPortStatusEntry  
SEQUENCE    
  dlcPortStatusId PortId
  dlcPortStatus PortStatusItem
  dlcPortStatusNetRxBwUtilization Gauge
  dlcPortStatusNetTxBwUtilization Gauge

DlcAlarmEntry  
SEQUENCE    
  dlcAlarmPort PortId
  dlcAlarmType AlarmType

DlcUserArchiveValidEntry  
SEQUENCE    
  dlcValidPortId PortId
  dlcValidIntervals INTEGER

DlcUserLifetimeEntry  
SEQUENCE    
  dlcLifetimePortId PortId
  dlcLifetimeES Gauge
  dlcLifetimeUAS Gauge
  dlcLifetimeCrcErrors Gauge
  dlcLifetimeBpvErrors Gauge
  dlcLifetimeOofErrors Gauge
  dlcLifetimeIbCrcErrors Gauge

DlcUserCurrentEntry  
SEQUENCE    
  dlcCurrentPortId PortId
  dlcCurrentES Counter
  dlcCurrentUAS Counter
  dlcCurrentCrcErrors Counter
  dlcCurrentBpvErrors Counter
  dlcCurrentOofErrors Counter
  dlcCurrentTimeElapsed INTEGER
  dlcCurrentIbCrcErrors Counter

DlcUserArchiveEntry  
SEQUENCE    
  dlcArchivePortId PortId
  dlcArchiveInterval INTEGER
  dlcArchiveES Counter
  dlcArchiveUAS Counter
  dlcArchiveCrcErrors Counter
  dlcArchiveBpvErrors Counter
  dlcArchiveOofErrors Counter
  dlcArchiveIbCrcErrors Counter
  dlcArchiveNetRxBwUtilization Gauge
  dlcArchiveNetRxPackets Counter
  dlcArchiveNetTxBwUtilization Gauge
  dlcArchiveNetTxPackets Counter

DlcUnitTestEntry  
SEQUENCE    
  dlcUnitTestPortId PortId
  dlcUnitTestType TestType
  dlcUnitTestPatternStatus INTEGER
  dlcUnitTestPatternErrors Gauge
  dlcLinkTestSentPackets Gauge
  dlcLinkTestReceivedPackets Gauge
  dlcLinkTestErroredPackets Gauge
  dlcLinkTestMissingPackets Gauge
  dlcLinkTestAverageRoundTrip Gauge
  dlcLinkTestMaximumRoundTrip Gauge

FramedUnframed  
INTEGER framed(1), unframed(2)    

RemoteCommunicationsMode  
INTEGER none(1), digital-link(2), att-TR54016(3), ansi-T1-403(4)    

DlcDelayMonitorConfigEntry  
SEQUENCE    
  dlcDelayMonitorConfigIndex INTEGER
  dlcDelayMonitorState INTEGER
  dlcDelayMonitorTargetAddress IpAddress
  dlcDelayMonitorDlci INTEGER
  dlcDelayMonitorPort INTEGER
  dlcDelayMonitorInterval INTEGER
  dlcDelayMonitorPacketSize INTEGER
  dlcDelayMonitorPattern INTEGER

DlcDelayMonitorStatusEntry  
SEQUENCE    
  dlcDelayMonitorStatusIndex INTEGER
  dlcDelayMonitorSentPackets Gauge
  dlcDelayMonitorReceivedPackets Gauge
  dlcDelayMonitorErroredPackets Gauge
  dlcDelayMonitorMissingPackets Gauge
  dlcDelayMonitorAverageRoundTrip Gauge
  dlcDelayMonitorMaximumRoundTrip Gauge

DlcDLCItableEntry  
SEQUENCE    
  dlcDLCInumber INTEGER
  dlcDTECIR INTEGER
  dlcNETCIR INTEGER
  dlcDLCIstatus INTEGER

DlcUtilTableEntry  
SEQUENCE    
  dlcUtilDLCINumber INTEGER
  dlcUtilEncodedValue OCTET STRING
  dlcUtilTimestamp Counter
  dlcUtilLessThan20 Counter
  dlcUtil20-40 Counter
  dlcUtil40-60 Counter
  dlcUtil60-80 Counter
  dlcUtil80-100 Counter
  dlcUtilMoreThan100 Counter

Defined Values


dl-new-t1 1.3.6.1.4.1.300.200
OBJECT IDENTIFIER    

dlcUnitHwConfig 1.3.6.1.4.1.300.200.1
OBJECT IDENTIFIER    

dlcUnitModelType 1.3.6.1.4.1.300.200.1.1
The unit model type.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER vxEncore(1), dl100Encore(2), dl1200(3), dl2400(4), dl600(5), dl600Encore(6), ensembleEncore(7), soloEncore(8), soloE1Encore(9), ensembleE1Encore(10), soloT1CSU(11), ensembleT1CSU(12), soloSelectT1Module(13), soloSelectE1Module(14), soloSelectT1(15), soloSelectE1(16), dl4200T1(17), dl4200E1(18), dl5440T1(19), dl5440E1(20)  

dlcUnitHwRev 1.3.6.1.4.1.300.200.1.2
The ASCII code of the hardware revision number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..4)  

dlcUnitHwOptions 1.3.6.1.4.1.300.200.1.3
A bit map, reported as the sum of all the values that correspond to installed options: realTimeClock ( 1) netPortT1 ( 2) netPortE1 ( 4) auxPortT1 ( 8) auxPortE1 ( 16) otherNetT1 ( 32) otherNetE1 ( 64) reserved1 (128) reserved2 (256) reserved3 (512) `netPortT1' and `netPortE1' are mutually exclusive and one of the two will always be TRUE. `auxPortT1' and `auxPortE1' are mutually exclusive; if both are FALSE, there is no AUX port present. `otherNetT1' and `otherNetE1' are mutually exclusive; if both are FALSE, there is no CSU port present.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1023  

dlcUnitSwRev 1.3.6.1.4.1.300.200.1.4
The ASCII code of the software revision number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..4)  

dlcUnitDataPorts 1.3.6.1.4.1.300.200.1.5
The number of data ports installed on the unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..32  

dlcUnitRam 1.3.6.1.4.1.300.200.1.6
The amount of usable ram in the unit, in KBytes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dlcUnitRom 1.3.6.1.4.1.300.200.1.7
The amount of usable rom in the unit, in KBytes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dlcUnitFlash 1.3.6.1.4.1.300.200.1.8
The amount of FLASH ROM in the unit, in KBytes. If dlcUnitFlash is 0, the Downloadable Code option is not installed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dlcUnitSlotNum 1.3.6.1.4.1.300.200.1.9
The slot number the unit is in. If it's a stand alone unit, this object will return 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

dlcUnitMibRev 1.3.6.1.4.1.300.200.1.10
The ASCII code of the MIB revision number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..4)  

dlcUnitFeatures 1.3.6.1.4.1.300.200.1.11
Feature configuration for Solo Select. The value returned is a bit mask of which feature key is on/capable when the corresponding bit is 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER inband(1), ipm32(2), ipm96(4), rmon2(8), sla(16), dni(32), dte2(64), reserved4(128), reserved5(256), reserved6(512), reserved7(1024), reserved8(2048)  

dlcUnitConfig 1.3.6.1.4.1.300.200.2
OBJECT IDENTIFIER    

dlcUnitId 1.3.6.1.4.1.300.200.2.1
A name that uniquely and globally identifies the unit. The Unit ID must consist of (upper-case) letters 'A'..'Z' and digits '0'..'9'. The first character of the Unit ID may not be a digit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..6)  

dlcUnitProtectMode 1.3.6.1.4.1.300.200.2.2
When true, the unit configuration can not be changed from the front panel nor can tests be initiated or terminated from the front panel.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Boolean  

dlcUnitYellowEnable 1.3.6.1.4.1.300.200.2.3
When false, yellow alarm conditions are ignored when received from a Dsx1 port, and the unit will never transmit a Yellow Alarm signal on a Dsx1 port. This applies to all ports: mainNet, aux, otherNet.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Boolean  

dlcUnitNetPassFdl 1.3.6.1.4.1.300.200.2.4
Indicates which Dsx1 DTE port's FDL is connected to the `mainNet' FDL when this unit has no traffic of its own. Meaninigful values are `aux', `otherNet', and `noPort'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  PortId  

dlcUnitMainClockSource 1.3.6.1.4.1.300.200.2.5
This is the primary transmit timing source.
Status: mandatory Access: read-write
OBJECT-TYPE    
  PortId  

dlcUnitAltClockSource 1.3.6.1.4.1.300.200.2.6
This is the alternate transmit timing source. It is used when the primary source is not available.
Status: mandatory Access: read-write
OBJECT-TYPE    
  PortId  

dlcUnitExtClockRate 1.3.6.1.4.1.300.200.2.7
The signal arriving at the BNC connector on the back of the unit, in units of KHz. Must be a multiple of 56 or 64 KHz (n*56 or n*64) or 1544. For T1 units, the largest acceptable value is 1544. For E1 units, the value can go up to 2048. For Solo CSU products, the value is fixed at 1544 and cannot be changed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 56..2048  

dlcUnitFullBandwidthLoopCode 1.3.6.1.4.1.300.200.2.8
Determines the loop codes we transmit for the Full Bandwidth Loop Up Remote and Loop Down Remote tests and the code we respond to when it's received on the NET port. For the fullBandwidthLoopCode, `v54' is an invalid value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  LoopCodeType  

dlcUnitFractionalLoopCode 1.3.6.1.4.1.300.200.2.9
Determines the loop codes we transmit for the Fractional Loop Up Remote and Loop Down Remote tests and the code we respond to when it's received on fractional bandwidth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  LoopCodeType  

dlcUnitTestLength 1.3.6.1.4.1.300.200.2.10
Determines the time interval after which tests are automatically terminated. Valid values are 0, 1, 15 and 60. 0 stands for unlimited, 1 for 1 minute, 15 for 15 minutes and 60 for 60 minutes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

dlcUnitUserPattern1 1.3.6.1.4.1.300.200.2.11
This is a sequence of the characters '0' and '1' that represents the first of two user patterns. The first character represents the first bit in the sequence.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..24)  

dlcUnitUserPattern2 1.3.6.1.4.1.300.200.2.12
This is a sequence of the characters '0' and '1' that represents the second of two user patterns. The first character represents the first bit in the sequence.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..24)  

dlcUnitBlockAllAlarms 1.3.6.1.4.1.300.200.2.13
When dlcUnitBlockAllAlarms is TRUE, the unit will never send any traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Boolean  

dlcUnitDsx1TrapEnableTable 1.3.6.1.4.1.300.200.2.14
A list of traps that are related to a Dsx1 port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DlcDsx1TrapEnableEntry

dlcDsx1TrapEnableEntry 1.3.6.1.4.1.300.200.2.14.1
An entry in the Dsx1 Trap Enable table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DlcDsx1TrapEnableEntry  

dlcDsx1TrapPortId 1.3.6.1.4.1.300.200.2.14.1.1
Uniquely identifies this port. Valid values are `mainNet', `aux', `otherNet'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PortId  

dlcDsx1BpvThresholdTrap 1.3.6.1.4.1.300.200.2.14.1.2
Defines Bipolar Violation Error Rate threshold in units of BPV errors per minute. When this threshold is exceeded, the unit will send a trap to the SNMP manager. The threshold is of the form M x 10 ^ -E where M is a mantissa and E the exponent. Both are single digit values. M and E are represented in this value as one number: (M) x 10 + (E). For example, the threshold 7x10^-3 BPVs/min is encoded as the integer 73. A value of 0 disables the trap altogether. Valid values for dlcDsx1BpvThresholdTrap are: 13 23 33 43 53 63 14 24 34 44 54 64 74 84 94 15 25 35 45 55 65 75 85 95 16 26 36 46 56 66 76 86 96 17 27 37 47 57 67 77 87 97 28 38 48 58 68 78 88 98 or, from 6E-3 to 2E-8. N.B. The BPV Threshold Alarm exists only for the mainNet and otherNet Port IDs, so setting the Threshold for the aux PortId will always fail. The BPV Threshold is always reported as 0 for the aux PortId.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..99  

dlcDsx1OofThresholdTrap 1.3.6.1.4.1.300.200.2.14.1.3
Defines the Out Of Frame Error Rate threshold in units of OOF errors per minute. The threshold is encoded the same as dlcDsx1BpvThresholdTrap. A value of 0 disables the trap altogether. Valid values for dlcDsx1OofThresholdTap are: 12 22 22 42 52 62 72 13 23 33 43 53 63 73 83 93 14 24 34 44 54 64 74 84 94 15 25 35 45 55 65 75 85 95 36 46 56 66 76 86 96 or, from 7E-2 to 3E-6. N.B. The OOF Threshold Alarm exists only for the mainNet and otherNet Port IDs, so setting the Threshold for the aux PortId will always fail. The OOF Threshold is always reported as 0 for the aux PortId.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..99  

dlcDsx1CrcThresholdTrap 1.3.6.1.4.1.300.200.2.14.1.4
Defines the CRC-6 Error Rate threshold in units of CRC errors per minute. The threshold is encoded the same as dlcDsx1BpvThresholdTrap. A value of 0 disables the trap altogether. Valid values for dlcDsx1CrcThresholdTrap are: 10 11 21 31 41 51 61 71 81 91 12 22 32 42 52 62 72 82 92 13 23 33 43 53 63 73 83 93 14 24 34 44 54 64 74 84 94 55 65 75 85 95 or, from 1E0 to 5E-5. N.B. The CRC Threshold Alarm exists only for the mainNet and otherNet Port IDs, so setting the Threshold for the aux PortId will always fail. The CRC Threshold is always reported as 0 for the aux PortId.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..99  

dlcDsx1LossOfSignalTrapEnable 1.3.6.1.4.1.300.200.2.14.1.5
Enables or disables a trap upon loss of network signal (LOS) on a Dsx1 port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Boolean  

dlcDsx1LossOfSyncTrapEnable 1.3.6.1.4.1.300.200.2.14.1.6
Enables or disables a trap upon loss of network framing (LOF) on a Dsx1 port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Boolean  

dlcDsx1ReceiveAIStrapEnable 1.3.6.1.4.1.300.200.2.14.1.7
Enables or disables a trap upon detection of AIS (Blue Alarm Signal) on a Dsx1 port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Boolean  

dlcDsx1ReceiveYellowAlarmTrapEnable 1.3.6.1.4.1.300.200.2.14.1.8
Enables or disables a trap upon detection of Yellow Alarm Signal on a Dsx1 port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Boolean  

dlcDsx1ReceiveRemoteAlarmTrapEnable 1.3.6.1.4.1.300.200.2.14.1.9
Enables or disables a trap upon detection of Remote Alarm Indicator on an E1 Dsx1 port. For T1 units, this object's value will always be read as 0 and set operations will succeed, but the value will not be changed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Boolean  

dlcDsx1PSfailureTrapEnable 1.3.6.1.4.1.300.200.2.14.1.10
Enables or disables a trap upon a power supply failure. This object doesn't really belong in the dlcDsx1TrapEnableTable. It is specific to units that are installed in a shelf. When accessing this object, the index (portId) is ignored.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Boolean  

dlcDsx1CntlCrdMissingTrapEnable 1.3.6.1.4.1.300.200.2.14.1.11
Enables or disables a trap upon detection of a missing controller card. This object doesn't really belong in the dlcDsx1TrapEnableTable. It is specific to units that are installed in a shelf. When accessing this object, the index (portId) is ignored.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Boolean  

dlcDsx1FdlLinkTrapEnable 1.3.6.1.4.1.300.200.2.14.1.12
Enables or disables a trap upon detection of the remote unit is not responding to DLC FDL messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Boolean  

dlcDsx1IbCrcThresholdTrap 1.3.6.1.4.1.300.200.2.14.1.13
Defines the In-Band CRC Error Rate threshold in units of CRC errors per minute. The threshold is encoded the same as dlcDsx1BpvThresholdTrap. A value of 0 disables the trap altogether. For the Eclipse, valid values of dlcDsx1IbCrcThresholdTrap range from 47 to 91. N.B. The CRC Threshold Alarm exists only for the mainNet port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..99  

dlcDsx1InbandLinkTrapEnable 1.3.6.1.4.1.300.200.2.14.1.14
Enables or disables a trap upon detection of the inband link.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Boolean  

dlcUnitDataDteLossTrapEnableTable 1.3.6.1.4.1.300.200.2.15
Enables or disables a trap upon the loss of signal on a Data DTE port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DlcDataDteLossTrapEnableEntry

dlcDataDteLossTrapEnableEntry 1.3.6.1.4.1.300.200.2.15.1
An entry in the Data DTE Loss Trap Enable table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DlcDataDteLossTrapEnableEntry  

dlcDataLossPortId 1.3.6.1.4.1.300.200.2.15.1.1
Uniquely identifies this port. Valid values are `data1' through `data32'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PortId  

dlcDataLossEnable 1.3.6.1.4.1.300.200.2.15.1.2
Says whether to enable this trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Boolean  

dlcUnitExternalAlarmInputTrapEnable 1.3.6.1.4.1.300.200.2.16
Enables or disables a trap upon detection of an alarm condition on the External Alarm Input.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Boolean  

dlcUnitExternalAlarmInputContacts 1.3.6.1.4.1.300.200.2.17
When set to normallyOpen, an alarm is declared when the contacts close ... and vice-versa.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normallyOpen(1), normallyClosed(2)  

dlcUnitExternalAlarmInputMessage 1.3.6.1.4.1.300.200.2.18
A character string that describes what's going on when an alarm on the External Alarm Input is detected.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..20)  

dlcUnitExternalAlarmOutputContacts 1.3.6.1.4.1.300.200.2.19
When set to normallyOpen, the contacts close when any enabled alarm occurs and vice-versa. Pushing any button on the units Front Panel will cause the alarm contacts to open again until another alarm is recognized.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normallyOpen(1), normallyClosed(2)  

dlcUnitExternalAlarmOutputTrapEnable 1.3.6.1.4.1.300.200.2.20
Enables or disables the external alarm output contacts.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Boolean  

dlcUnitDsx1ConfigTable 1.3.6.1.4.1.300.200.2.21
A table of configuration items for a Dsx1 port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DlcDsx1ConfigEntry

dlcDsx1ConfigEntry 1.3.6.1.4.1.300.200.2.21.1
An entry in the Dsx1 configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DlcDsx1ConfigEntry  

dlcDsx1ConfigPortId 1.3.6.1.4.1.300.200.2.21.1.1
Uniquely identifies this port. Valid values are `mainNet', `aux', `otherNet'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PortId  

dlcDsx1Framing 1.3.6.1.4.1.300.200.2.21.1.2
Dsx1 framing type: T1 --> D4 or ESF; E1 --> CRC4 or not. Unstructured is E1 only, when in this mode, the E1 line acts like a 2048 Bps pipe with no framing information.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER esfFraming(1), d4Framing(2), crc4Enabled(3), crc4Disabled(4), unstructured(5)  

dlcDsx1LineCode 1.3.6.1.4.1.300.200.2.21.1.3
Dsx1 line code type, AMI or B8ZS. E1 lines are always HDB3.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER b8zsCode(1), amiCode(2), hdb3Code(3)  

dlcDsx1LineMatching 1.3.6.1.4.1.300.200.2.21.1.4
Dsx1 line build out or equalization: For a T1 NET port, LBO is 0, -7.5 or -15dB. For a T1 AUX port, EQ is 0..533 feet. For any E1 port, impedance is 75 or 120 Ohms.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER buildOut0(1), buildOut7p5(2), buildOut15(3), length0(4), length133(5), length266(6), length399(7), length533(8), ohms75(9), ohms120(10)  

dlcDsx1DacsMode 1.3.6.1.4.1.300.200.2.21.1.5
True if DACS mode is in effect for this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Boolean  

dlcDsx1UseDlcFdlProtocol 1.3.6.1.4.1.300.200.2.21.1.6
True when DLC FDL protocol is enabled over this port's FDL.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Boolean  

dlcDsx1UseAnsiProtocol 1.3.6.1.4.1.300.200.2.21.1.7
True if ANSI Dsx1.403 is enabled over the FDL.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Boolean  

dlcDsx1Bit7Stuffing 1.3.6.1.4.1.300.200.2.21.1.8
When true, bit 7 stuffing is turned on for a T1 Aux port to provide pulse density protection. Valid only on a T1 AUX port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Boolean  

dlcDsx1InBandBit 1.3.6.1.4.1.300.200.2.21.1.9
Specifies which bit in Timeslot 1 of an E1 link is used to pass message traffic. Not implemented for T1 ports.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..8  

dlcUnitDataDteConfigTable 1.3.6.1.4.1.300.200.2.22
The data DTE configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DlcDataDteConfigEntry

dlcDataDteConfigEntry 1.3.6.1.4.1.300.200.2.22.1
An entry in the data DTE configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DlcDataDteConfigEntry  

dlcDataConfigPortId 1.3.6.1.4.1.300.200.2.22.1.1
Uniquely identifies this port. Valid values are `data1' through `data32'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PortId  

dlcDataConfigEncoding 1.3.6.1.4.1.300.200.2.22.1.2
Data DTE encoding type.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), hdlc(2), deferred(3), forced(4)  

dlcDataConfigLoss 1.3.6.1.4.1.300.200.2.22.1.3
The criterion to declare a Loss of Data DTE.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER never(1), rtsLoss(2), dtrLoss(3), dataDependentLoss(4)  

dlcDataConfigMode 1.3.6.1.4.1.300.200.2.22.1.4
In dteMode the unit is the DTE and the external equipment the DCE.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dteMode(1), dceMode(2)  

dlcDataConfigFormat 1.3.6.1.4.1.300.200.2.22.1.5
Selects V.35 or RS449 format.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER v35(1), rs449(2)  

dlcDataConfigTransmitTiming 1.3.6.1.4.1.300.200.2.22.1.6
Selects the Data DTE tramsmit timing source. Can be SCTE, SCT or inverted SCT.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER scte(1), sct(2), sctInverted(3)  

dlcUnitMuxConfigTable 1.3.6.1.4.1.300.200.2.23
This is the timeslot map configuration.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DlcMuxConfigEntry

dlcMuxConfigEntry 1.3.6.1.4.1.300.200.2.23.1
An entry in the timeslot map.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DlcMuxConfigEntry  

dlcMuxConfigBusId 1.3.6.1.4.1.300.200.2.23.1.1
Identifies which muxBus this timeslot is on.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER primary(1), secondary(2)  

dlcMuxConfigSlotNumber 1.3.6.1.4.1.300.200.2.23.1.2
Uniquely identifies this timeslot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..31  

dlcMuxConfigPortId 1.3.6.1.4.1.300.200.2.23.1.3
Says which DTE port receives data from the indicated muxBus during this timeslot.
Status: mandatory Access: read-write
OBJECT-TYPE    
  PortId  

dlcUnitSnmpConfig 1.3.6.1.4.1.300.200.2.24
OBJECT IDENTIFIER    

dlcSnmpUnitIpAddr 1.3.6.1.4.1.300.200.2.24.1
Specifies the IP address that is assigned to this unit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

dlcSnmpUnitNetMask 1.3.6.1.4.1.300.200.2.24.2
Specifies the net mask that this unit uses.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

dlcSnmpTrapAddr1 1.3.6.1.4.1.300.200.2.24.3
Specifies the IP address of the management station to which this unit sends traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

dlcSnmpTrapAddr2 1.3.6.1.4.1.300.200.2.24.4
Specifies the IP address of the management station to which this unit sends traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

dlcSnmpTrapAddr3 1.3.6.1.4.1.300.200.2.24.5
Specifies the IP address of the management station to which this unit sends traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

dlcSnmpTrapDlci1 1.3.6.1.4.1.300.200.2.24.6
Specifies the first of three DLCI value to which this unit sends TRAP PDUs.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

dlcSnmpTrapDlci2 1.3.6.1.4.1.300.200.2.24.7
Specifies the second of three DLCI value to which this unit sends TRAP PDUs.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

dlcSnmpTrapDlci3 1.3.6.1.4.1.300.200.2.24.8
Specifies the third of three DLCI value to which this unit sends TRAP PDUs.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

dlcSnmpTrapDirection1 1.3.6.1.4.1.300.200.2.24.9
Specifies the first of three Port to which this unit sends TRAP PDUs.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER commDirection(1), netDirection(2), dteDirection(3), fdlDirection(4), ethDirection(5)  

dlcSnmpTrapDirection2 1.3.6.1.4.1.300.200.2.24.10
Specifies the second of three Port to which this unit sends TRAP PDUs.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER commDirection(1), netDirection(2), dteDirection(3), fdlDirection(4), ethDirection(5)  

dlcSnmpTrapDirection3 1.3.6.1.4.1.300.200.2.24.11
Specifies the third of three Port to which this unit sends TRAP PDUs.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER commDirection(1), netDirection(2), dteDirection(3), fdlDirection(4), ethDirection(5)  

dlcSnmpTrapDirection 1.3.6.1.4.1.300.200.2.24.12
Specifies where this unit sends TRAP PDUs.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER commDirection(1), ibcDirection(2)  

dlcSnmpEthernetConfiguration 1.3.6.1.4.1.300.200.2.24.13
OBJECT IDENTIFIER    

dlcEthernetIpAddr 1.3.6.1.4.1.300.200.2.24.13.1
Specifies the IP address of Ethernet port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

dlcEthernetIpMask 1.3.6.1.4.1.300.200.2.24.13.2
Specifies the subnet mask of Ethernet port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

dlcEthernetGatewayAddr 1.3.6.1.4.1.300.200.2.24.13.3
Specifies the gateway address of Ethernet port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

dlcEthernetMacAddr 1.3.6.1.4.1.300.200.2.24.13.4
The MAC address of the Ethernet port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  MacAddress  

dlcUnitConfigTime 1.3.6.1.4.1.300.200.2.25
OBJECT IDENTIFIER    

dlcUnitTimeYear 1.3.6.1.4.1.300.200.2.25.1
The unit's notion of the current year.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1992..2037  

dlcUnitTimeMonth 1.3.6.1.4.1.300.200.2.25.2
The unit's notion of the current month.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..12  

dlcUnitTimeDay 1.3.6.1.4.1.300.200.2.25.3
The unit's notion of the current day.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..31  

dlcUnitTimeHour 1.3.6.1.4.1.300.200.2.25.4
The the unit's notion of the current hour.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..23  

dlcUnitTimeMinute 1.3.6.1.4.1.300.200.2.25.5
The the unit's notion of the current minute.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..59  

dlcUnitTimeSecond 1.3.6.1.4.1.300.200.2.25.6
The the unit's notion of the current second.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..59  

dlcUnitSerialNum 1.3.6.1.4.1.300.200.2.26
An ID that uniquely and globally identifies the unit. A Serial Number must consist of printable ASCII characters 0x20 ..0x7E.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..20)  

dlcUnitModemConfig 1.3.6.1.4.1.300.200.2.27
OBJECT IDENTIFIER    

dlcModemPhoneNum1 1.3.6.1.4.1.300.200.2.27.1
The first phone number to dial when the unit needs to set up a modem connection.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..20)  

dlcModemPhoneNum2 1.3.6.1.4.1.300.200.2.27.2
The second phone number to try if the phone number failed in setting up a modem connection.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..20)  

dlcModemInitString1 1.3.6.1.4.1.300.200.2.27.3
In setting up a modem connection, the first group of commands used to initialize the modem.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..20)  

dlcModemInitString2 1.3.6.1.4.1.300.200.2.27.4
In setting up a modem connection, the second group of commands used to initialize the modem. There is a delay between sending the first and second groups of initialzation commands.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..60)  

dlcUnitInbandMode 1.3.6.1.4.1.300.200.2.28
The type of traffic expected on the link for inband management and IPM.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noInband(1), frameRelay(2), ciscoHdlc(3)  

dlcUnitStatus 1.3.6.1.4.1.300.200.3
OBJECT IDENTIFIER    

dlcUnitCurrentStatus 1.3.6.1.4.1.300.200.3.1
What's going on in this unit?
Status: mandatory Access: read-only
OBJECT-TYPE    
  UnitStatusItem  

dlcUnitErrorFreeSeconds 1.3.6.1.4.1.300.200.3.2
Represents the percent of error free seconds over the last 24 hours. The number is multiplied by 10 and rounded to the nearest integer. For example, 94.2% is encoded as 942.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dlcUnitLastSelfTestResult 1.3.6.1.4.1.300.200.3.3
The result of the last self test. unitLastSelfTest is a bitmap ... the sum of: 0 Selftest passed 1 ROM checksum failure 2 RAM test failure 4 EEPROM CRC failure 8 DTE test failure 16 Pattern loss during test 32 FLASH checksum failure 64 reserved 128 reserved 256 reserved 512 reserved A result of 0 means no errors occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1023  

dlcUnitPortStatusTable 1.3.6.1.4.1.300.200.3.4
A table of all port-related status
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DlcPortStatusEntry

dlcPortStatusEntry 1.3.6.1.4.1.300.200.3.4.1
An entry in the port status table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DlcPortStatusEntry  

dlcPortStatusId 1.3.6.1.4.1.300.200.3.4.1.1
Identifies which port (NET, AUX, Data DTE, or whatever) this status entry is describing.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PortId  

dlcPortStatus 1.3.6.1.4.1.300.200.3.4.1.2
Gives the actual status value for to this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PortStatusItem  

dlcPortStatusNetRxBwUtilization 1.3.6.1.4.1.300.200.3.4.1.3
Represents the percent of net receive bandwidth utilization over the last 60 seconds. The number is multiplied by 10 and rounded to the nearest integer. For example, 94.2% is encoded as 942.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dlcPortStatusNetTxBwUtilization 1.3.6.1.4.1.300.200.3.4.1.4
Represents the percent of net receive bandwidth utilization over the last 60 seconds. The number is multiplied by 10 and rounded to the nearest integer. For example, 94.2% is encoded as 942.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dlcUnitAlarmTable 1.3.6.1.4.1.300.200.3.5
A table of all currently-raised alarms
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DlcAlarmEntry

dlcAlarmEntry 1.3.6.1.4.1.300.200.3.5.1
An entry in the alarm table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DlcAlarmEntry  

dlcAlarmPort 1.3.6.1.4.1.300.200.3.5.1.1
Identifies which port (NET, AUX, Data DTE, or whatever) this alarm relates to.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PortId  

dlcAlarmType 1.3.6.1.4.1.300.200.3.5.1.2
Identifies an alarm that's currently outstanding against this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  AlarmType  

dlcUnitErrorSecondsRatio 1.3.6.1.4.1.300.200.3.6
Represents the percent of error seconds over the last 24 hours. The number is multiplied by 10 and rounded to the nearest integer. For example, 94.2% is encoded as 942.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dlcUnitSeverelyErroredSecondsRatio 1.3.6.1.4.1.300.200.3.7
Represents the percent of severely errored seconds over the last 24 hours. The number is multiplied by 10 and rounded to the nearest integer. For example, 94.2% is encoded as 942.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dlcUnitBackgroundBlockErrorRatio 1.3.6.1.4.1.300.200.3.8
Represents the percent of background block errors over the last 24 hours. The number is multiplied by 10 and rounded to the nearest integer. For example, 94.2% is encoded as 942.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dlcUnitUserArchive 1.3.6.1.4.1.300.200.4
OBJECT IDENTIFIER    

dlcUnitUserArchiveValidTable 1.3.6.1.4.1.300.200.4.1
A table of all port-related status
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DlcUserArchiveValidEntry

dlcUserArchiveValidEntry 1.3.6.1.4.1.300.200.4.1.1
An entry in the user archive valid-intervals table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DlcUserArchiveValidEntry  

dlcValidPortId 1.3.6.1.4.1.300.200.4.1.1.1
Identifies which port (`net' or `otherNet') this entry is describing.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PortId  

dlcValidIntervals 1.3.6.1.4.1.300.200.4.1.1.2
The number of valid intervals in the user's error register database for this port. Writing a 0 to this variable will clear the entire archive for this port. Writing any other value is a no-op.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..96  

dlcUnitUserLifetimeTable 1.3.6.1.4.1.300.200.4.2
A table of the lifetime error counts, per-port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DlcUserLifetimeEntry

dlcUserLifetimeEntry 1.3.6.1.4.1.300.200.4.2.1
An entry in the user archive lifetime-totals table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DlcUserLifetimeEntry  

dlcLifetimePortId 1.3.6.1.4.1.300.200.4.2.1.1
Identifies which port (`net' or `otherNet') this entry relates to.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PortId  

dlcLifetimeES 1.3.6.1.4.1.300.200.4.2.1.2
An ongoing count of Errored Seconds detected on this network port. Can be read and written (to zero).
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

dlcLifetimeUAS 1.3.6.1.4.1.300.200.4.2.1.3
An ongoing count of Unavailable Seconds detected on this network port. Can be read and written (to zero).
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

dlcLifetimeCrcErrors 1.3.6.1.4.1.300.200.4.2.1.4
An ongoing count of the CRC errors detected on this network port. Can be read and written (to zero).
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

dlcLifetimeBpvErrors 1.3.6.1.4.1.300.200.4.2.1.5
An ongoing count of the Code Violation errors detected on this network port. Can be read and written (to zero).
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

dlcLifetimeOofErrors 1.3.6.1.4.1.300.200.4.2.1.6
For an ESF T1 port, an ongoing count of Out-Of-Frame errors. For a D4 T1 port, an ongoing count of Framing Errors. Available only for the network port. Can be read and written (to zero).
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

dlcLifetimeIbCrcErrors 1.3.6.1.4.1.300.200.4.2.1.7
An ongoing count of the FCS errors detected on this network port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

dlcUnitUserCurrentTable 1.3.6.1.4.1.300.200.4.3
A table of all the current interval error counts, per-port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DlcUserCurrentEntry

dlcUserCurrentEntry 1.3.6.1.4.1.300.200.4.3.1
An entry in the user archive current interval table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DlcUserCurrentEntry  

dlcCurrentPortId 1.3.6.1.4.1.300.200.4.3.1.1
Identifies which port (`net' or `otherNet') this entry relates to.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PortId  

dlcCurrentES 1.3.6.1.4.1.300.200.4.3.1.2
Errored seconds in the interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

dlcCurrentUAS 1.3.6.1.4.1.300.200.4.3.1.3
Unavailable seconds in the interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

dlcCurrentCrcErrors 1.3.6.1.4.1.300.200.4.3.1.4
CRC Errors in the interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

dlcCurrentBpvErrors 1.3.6.1.4.1.300.200.4.3.1.5
Code Violation Errors in the interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

dlcCurrentOofErrors 1.3.6.1.4.1.300.200.4.3.1.6
OOF or Framing Errors in the interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

dlcCurrentTimeElapsed 1.3.6.1.4.1.300.200.4.3.1.7
The number of seconds that have elapsed since the beginning of the current error-measurement period. Available only for the network port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..899  

dlcCurrentIbCrcErrors 1.3.6.1.4.1.300.200.4.3.1.8
FCS Errors in the interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

dlcUnitUserArchiveTable 1.3.6.1.4.1.300.200.4.4
A table of all the archive intervals' error counts, per-port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DlcUserArchiveEntry

dlcUserArchiveEntry 1.3.6.1.4.1.300.200.4.4.1
An entry in the user archive table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DlcUserArchiveEntry  

dlcArchivePortId 1.3.6.1.4.1.300.200.4.4.1.1
Identifies which port (`net' or `otherNet') this entry relates to.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PortId  

dlcArchiveInterval 1.3.6.1.4.1.300.200.4.4.1.2
Identifies which interval this secondaryArchiveEntry describes. 1 indicates the most-recent interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..96  

dlcArchiveES 1.3.6.1.4.1.300.200.4.4.1.3
Errored seconds in the interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

dlcArchiveUAS 1.3.6.1.4.1.300.200.4.4.1.4
Unavailable seconds in the interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

dlcArchiveCrcErrors 1.3.6.1.4.1.300.200.4.4.1.5
CRC Errors in the interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

dlcArchiveBpvErrors 1.3.6.1.4.1.300.200.4.4.1.6
Code Violation Errors in the interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

dlcArchiveOofErrors 1.3.6.1.4.1.300.200.4.4.1.7
OOF or Framing Errors in the interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

dlcArchiveIbCrcErrors 1.3.6.1.4.1.300.200.4.4.1.8
FCS Errors in the interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

dlcArchiveNetRxBwUtilization 1.3.6.1.4.1.300.200.4.4.1.9
Net Rx Bandwidth Utilization in the interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dlcArchiveNetRxPackets 1.3.6.1.4.1.300.200.4.4.1.10
Net Rx Packets in the interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

dlcArchiveNetTxBwUtilization 1.3.6.1.4.1.300.200.4.4.1.11
Net Tx Bandwidth Utilization in the interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dlcArchiveNetTxPackets 1.3.6.1.4.1.300.200.4.4.1.12
Net Tx Packets in the interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

dlcUnitTest 1.3.6.1.4.1.300.200.5
OBJECT IDENTIFIER    

dlcUnitTestTable 1.3.6.1.4.1.300.200.5.1
A table containing all currently active tests. The initial release of the product's firmware does not include multiple tests. However, a later version will allow a number of tests to be active at a time. This MIB object structure allows any number of tests to be running at any time. Upon receiving a SET request, the unit compares this table with the list of currently active tests and terminates or initiates any tests as required. However, this does not apply to Link Based Test. dlcUnitConfigLinkTest group contains objects to configure and start Link Based Test. This table only contains the statistics for Link Based Test.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DlcUnitTestEntry

dlcUnitTestEntry 1.3.6.1.4.1.300.200.5.1.1
An entry in the network configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DlcUnitTestEntry  

dlcUnitTestPortId 1.3.6.1.4.1.300.200.5.1.1.1
Identifies a port that a test might be running on. By convention, Self Test and all full-bandwidth tests (loopbacks, patterns, etc.) are assigned to the netPort. For E1 unit, if it is in unstructured mode, only full-bandwidth tests can be performed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PortId  

dlcUnitTestType 1.3.6.1.4.1.300.200.5.1.1.2
Says what test is running on this port. Note that the following test nomenclature is equivalent: SNMP Terminal UI Front Panel 1in8 1:7 1:7 3in24 3:24 3.24 1in1 1:1 1:1 AllOne All 1 1's AllZero All 0 0's 1in3 1:2 1:2 1in5 1:4 1:4 The SNMP test identifiers use the names on the left. The terminal User Interface uses the names in the middle column, and the unit's front panel uses the names in the right column.
Status: mandatory Access: read-write
OBJECT-TYPE    
  TestType  

dlcUnitTestPatternStatus 1.3.6.1.4.1.300.200.5.1.1.3
The current state of the Pattern Test module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER search(1), locked(2), overflow(3), off(4), lockedAfterLoss(5)  

dlcUnitTestPatternErrors 1.3.6.1.4.1.300.200.5.1.1.4
An ongoing count of errors detected by the Pattern Generator/Detector. Can be read and written (to zero).
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

dlcLinkTestSentPackets 1.3.6.1.4.1.300.200.5.1.1.5
Number of sent packets for the currently running link based test.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dlcLinkTestReceivedPackets 1.3.6.1.4.1.300.200.5.1.1.6
Number of good received packets for the currently running link based test.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dlcLinkTestErroredPackets 1.3.6.1.4.1.300.200.5.1.1.7
Number of errored received packets for the currently running link based test.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dlcLinkTestMissingPackets 1.3.6.1.4.1.300.200.5.1.1.8
Number of missing packets for the currently running link based test.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dlcLinkTestAverageRoundTrip 1.3.6.1.4.1.300.200.5.1.1.9
Average round trip time in milli seconds for the currently running link based test.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dlcLinkTestMaximumRoundTrip 1.3.6.1.4.1.300.200.5.1.1.10
Maximum round trip time in milli seconds for the currently running link based test.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dlcUnitDialOutTimeInterval 1.3.6.1.4.1.300.200.2.29
A time interval for the dialout. The value should be between 0 and 255.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

dlcAlarmSignal 1.3.6.1.4.1.300.200.2.30
Framed/unframed aux alarm signal option
Status: mandatory Access: read-write
OBJECT-TYPE    
  FramedUnframed  

dlcUnitIdleCode 1.3.6.1.4.1.300.200.2.31
Idle Code that is send on unassigned time slots
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

dlcRemoteCommunicationsMode 1.3.6.1.4.1.300.200.2.32
Framed/unframed aux alarm signal option
Status: mandatory Access: read-write
OBJECT-TYPE    
  RemoteCommunicationsMode  

dlcUnitConfigLinkTest 1.3.6.1.4.1.300.200.2.33
OBJECT IDENTIFIER    

dlcLinkTestState 1.3.6.1.4.1.300.200.2.33.1
Specifies the status configuration of link based test. Only setable to values disabled(1) and enabled(2) to end and start the test respectively. Values running(3) and idle(4) are returned for status of the test.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2), running(3), idle(4)  

dlcLinkTestAddress 1.3.6.1.4.1.300.200.2.33.2
Specifies the address for the next link based test to run.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

dlcLinkTestDlci 1.3.6.1.4.1.300.200.2.33.3
Specifies the frame relay DLCI for the next link based test to run. This value is used when the unit is in frameRelay InbandMode only and if the next link based test is not done on the commPort.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1023  

dlcLinkTestPort 1.3.6.1.4.1.300.200.2.33.4
Specifies which port to run the next link based test.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER comm(1), net(2), dte(3), eth(4)  

dlcLinkTestLength 1.3.6.1.4.1.300.200.2.33.5
Specifies the time length of the next test to run in minutes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

dlcLinkTestInterval 1.3.6.1.4.1.300.200.2.33.6
Specifies the repetition interval in seconds between packets for the next link based test.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..3600  

dlcLinkTestPacketSize 1.3.6.1.4.1.300.200.2.33.7
Specifies the packet size for the next link based test.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1500  

dlcLinkTestPattern 1.3.6.1.4.1.300.200.2.33.8
Specifies the test pattern for the next link based test.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ping511(1), ping2047(2), ping1-0(3), ping-all-1(4), ping-all-0(5)  

dlcUnitInbandConfig 1.3.6.1.4.1.300.200.2.34
When true (== 2), inband management is enabled.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Boolean  

dlcUnitInbandTrafficType 1.3.6.1.4.1.300.200.2.35
The type of traffic expected on the link for inband management and IPM.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER frameRelay(1), ciscoHdlc(2)  

dlcUnitPerformanceMonitoring 1.3.6.1.4.1.300.200.2.36
When true (== 2), the integrated performance monitoring (IPM) is enabled
Status: mandatory Access: read-write
OBJECT-TYPE    
  Boolean  

dlcUnitPvcAutoDiscovery 1.3.6.1.4.1.300.200.2.37
When true (== 2), automatic discovery of DLCIs is enabled
Status: mandatory Access: read-write
OBJECT-TYPE    
  Boolean  

dlcUnitDelayMonitorConfig 1.3.6.1.4.1.300.200.2.38
OBJECT IDENTIFIER    

dlcDelayMonitorConfigTable 1.3.6.1.4.1.300.200.2.38.1
Table of Delay Monitor test configuration.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DlcDelayMonitorConfigEntry

dlcDelayMonitorConfigEntry 1.3.6.1.4.1.300.200.2.38.1.1
An entry in the network configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DlcDelayMonitorConfigEntry  

dlcDelayMonitorConfigIndex 1.3.6.1.4.1.300.200.2.38.1.1.1
Uniquely identifies which delay monitor test in the configuration table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

dlcDelayMonitorState 1.3.6.1.4.1.300.200.2.38.1.1.2
Specifies the status configuration of this delay monitor. Only setable to values disabled(1) and enabled(2) to end and start the test respectively. Values running(3) and idle(4) are returned for status of the test.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2), running(3), idle(4)  

dlcDelayMonitorTargetAddress 1.3.6.1.4.1.300.200.2.38.1.1.3
Specifies the address for the next delay monitor to run.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

dlcDelayMonitorDlci 1.3.6.1.4.1.300.200.2.38.1.1.4
Specifies the frame relay DLCI for the next delay monitor to run. This value is used when the unit is in frameRelay InbandMode only and if the next delay monitor is not done on the commPort.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1023  

dlcDelayMonitorPort 1.3.6.1.4.1.300.200.2.38.1.1.5
Specifies which port to run the next delay monitor.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER comm(1), net(2), dte(3), eth(4)  

dlcDelayMonitorInterval 1.3.6.1.4.1.300.200.2.38.1.1.6
Specifies the repetition interval in seconds between packets for the next delay monitor to run.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..3600  

dlcDelayMonitorPacketSize 1.3.6.1.4.1.300.200.2.38.1.1.7
Specifies the packet size for the next delay monitor.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1500  

dlcDelayMonitorPattern 1.3.6.1.4.1.300.200.2.38.1.1.8
Specifies the test pattern for the next delay monitor.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ping511(1), ping2047(2), ping1-0(3), ping-all-1(4), ping-all-0(5)  

dlcUnitDelayMonitorStatus 1.3.6.1.4.1.300.200.6
OBJECT IDENTIFIER    

dlcDelayMonitorStatusTable 1.3.6.1.4.1.300.200.6.1
Table of Delay Monitor status.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DlcDelayMonitorStatusEntry

dlcDelayMonitorStatusEntry 1.3.6.1.4.1.300.200.6.1.1
An entry in the network configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DlcDelayMonitorStatusEntry  

dlcDelayMonitorStatusIndex 1.3.6.1.4.1.300.200.6.1.1.1
Uniquely identifies which Delay Monitor test in the configuration table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

dlcDelayMonitorSentPackets 1.3.6.1.4.1.300.200.6.1.1.2
Number of sent packets for the currently running delay monitor test.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dlcDelayMonitorReceivedPackets 1.3.6.1.4.1.300.200.6.1.1.3
Number of good received packets for the currently running delay monitor test.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dlcDelayMonitorErroredPackets 1.3.6.1.4.1.300.200.6.1.1.4
Number of errored received packets for the currently running delay monitor test.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dlcDelayMonitorMissingPackets 1.3.6.1.4.1.300.200.6.1.1.5
Number of missing packets for the currently running delay monitor test.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dlcDelayMonitorAverageRoundTrip 1.3.6.1.4.1.300.200.6.1.1.6
Average round trip time in milli seconds for the currently running delay monitor test.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dlcDelayMonitorMaximumRoundTrip 1.3.6.1.4.1.300.200.6.1.1.7
Maximum round trip time in milli seconds for the currently running delay monitor test.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dlcDLCItable 1.3.6.1.4.1.300.200.2.39
Table for current DLCI
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DlcDLCItableEntry

dlcDLCItableEntry 1.3.6.1.4.1.300.200.2.39.1
An entry for a DLCI
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DlcDLCItableEntry  

dlcDLCInumber 1.3.6.1.4.1.300.200.2.39.1.1
Identifies DLCI number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..1023  

dlcDTECIR 1.3.6.1.4.1.300.200.2.39.1.2
This DLCI's DTE Confirmed Information Rate (CIR)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dlcNETCIR 1.3.6.1.4.1.300.200.2.39.1.3
This DLCI's NET Confirmed Information Rate (CIR)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dlcDLCIstatus 1.3.6.1.4.1.300.200.2.39.1.4
This object represents status of the entry. When read, it will return status 'active' or 'inactive' representing the status of the row. When written, this object is used to add or delete entry. Setting to 'enabled' will add a new entry, setting to 'disabled' will delete the entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), active(3), inactive(4)  

dlcUtilizationTable 1.3.6.1.4.1.300.200.7
Table for lifetime Utilization statistics.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DlcUtilTableEntry

dlcUtilTableEntry 1.3.6.1.4.1.300.200.7.1
An entry for the utilization table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DlcUtilTableEntry  

dlcUtilDLCINumber 1.3.6.1.4.1.300.200.7.1.1
Identifies the DLCI number of the utilization statistics of this entry/row.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dlcUtilEncodedValue 1.3.6.1.4.1.300.200.7.1.2
This object represents the value of the whole row of the table. The intent of object is to increase the efficiency of retrieving the table. For each object value in this table, which are all of Counter type, it will be represented with 4 bytes of data.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

dlcUtilTimestamp 1.3.6.1.4.1.300.200.7.1.3
Identifies timestamp when this entry is last updated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

dlcUtilLessThan20 1.3.6.1.4.1.300.200.7.1.4
The number of times utilization is less than 20% of Committed Information Rate (CIR).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

dlcUtil20-40 1.3.6.1.4.1.300.200.7.1.5
The number of times utilization is between 20% and 40% of Committed Information Rate (CIR).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

dlcUtil40-60 1.3.6.1.4.1.300.200.7.1.6
The number of times utilization is between 40% and 60% of Committed Information Rate (CIR).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

dlcUtil60-80 1.3.6.1.4.1.300.200.7.1.7
The number of times utilization is between 60% and 80% of Committed Information Rate (CIR).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

dlcUtil80-100 1.3.6.1.4.1.300.200.7.1.8
The number of times utilization is between 80% and 100% of Committed Information Rate (CIR).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

dlcUtilMoreThan100 1.3.6.1.4.1.300.200.7.1.9
The number of times utilization is more than 100% of Committed Information Rate (CIR).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

dlcLMIConditioningGroup 1.3.6.1.4.1.300.200.2.41
OBJECT IDENTIFIER    

dlcLMIConfiguration 1.3.6.1.4.1.300.200.2.41.1
OBJECT IDENTIFIER    

dlcLMIEnable 1.3.6.1.4.1.300.200.2.41.1.1
This object specifies whether to enable or disable LMI Conditioning.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

dlcMaintenanceDLCI 1.3.6.1.4.1.300.200.2.41.1.2
This objects specifies the status of the LMI Spoofing.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 16..991  

dlcManagementDLCI 1.3.6.1.4.1.300.200.2.41.1.3
This objects specifies the number of management DLCI between 16 and 991 inclusive. Must not be the same as maintenance DLCI. Default is 989.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 16..991  

dlcManagementDLCIEnable 1.3.6.1.4.1.300.200.2.41.1.4
This object specifies whether to enable or disable Management DLCI.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

dlcSpoofingProtocolType 1.3.6.1.4.1.300.200.2.41.1.5
This objects configures which LMI message type to 'spoof', in the event that spoofing is activated. The possible choices are FRF 1.0 (Frame Relay Forum's early LMI adaptation), Annex A (ITU Q.933, annex A), and Annex D (ANSI T1.617, annex D). Default is Annex D.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER frf1-0(1), annex-d(2), annex-a(3)  

dlcDTESpoofingEnable 1.3.6.1.4.1.300.200.2.41.1.6
If the value of this object is 'enabled', LMI spoofing to the DTE port is done automatically.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

dlcNetSpoofingEnable 1.3.6.1.4.1.300.200.2.41.1.7
If the value of this object is 'enabled', LMI spoofing to the Network port is done automatically.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

dlcLinkIntegrityVerificationPollingTimer 1.3.6.1.4.1.300.200.2.41.1.8
This object is the interval in seconds between Link Integrity Verification Messages. This is known as T391 in the standards. Possible values are 5 to 30 seconds in increments of 5. Default is 10 seconds.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 5..30  

dlcFullStatusPollingCounter 1.3.6.1.4.1.300.200.2.41.1.9
This value corresponds to N391 in the ITU and ANSI standards. It is the number of polling cycles of the type before the unit generates the full status request. Possible values are 1 to 255. Default is 10.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

dlcLMIErrorEvent 1.3.6.1.4.1.300.200.2.41.1.10
This object configures the parameter which sets the number of errors that can occur on the LMI link in LMI Error Monitored Events before reporting an interface down. Applies to the DTE and Network ports. This is used in the same manner as the N392 parameter (N2) in the standards. Possible values are 1 to 10. Default is 1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..10  

dlcLMIErrorMonitorEvent 1.3.6.1.4.1.300.200.2.41.1.11
This object configures parameter which sets the number of events that are used with the LMI Error Event to define the error ratio that is used to report when the LMI link is down. Applies to the DTE and Network ports. This value is used in the same manner as the N393 parameter (N3) in the standards.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..10  

dlcLMIErrorFreeEvent 1.3.6.1.4.1.300.200.2.41.1.12
This object configures the parameter which sets the number of error-free messages that must be received in LMI Error Free Monitored Events prior to declaring an interface is up. Applies to the DTE and Network ports. For network spoofing, this is the number of error-free events that will cause the DSU to believe the network is back up and runnig, and the DSU will stop spoofing. This is used in the same manner as the N392 parameter (N2) in the standards. Possible values are 1 to 10. Default is 1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..10  

dlcLMIErrorFreeMonitorEvent 1.3.6.1.4.1.300.200.2.41.1.13
This object configures parameter which sets the number of events that are used with the LMI Error Free Event to define the error ratio that is used to report that the LMI link is up. Applies to the DTE and Network ports. This is used in the same manner as the N393 parameter (N3) in the standards.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..10  

dlcDTEResponseTimer 1.3.6.1.4.1.300.200.2.41.1.14
This object configures the parameter which sets the number of seconds between the sending of a status enquiry message and the receipt of a response. Applies to the DTE port. This value is similar in nature to the T392 (T2) parameter in the standards. Possible values are 5 to 30 in increments of 5. Default is 15.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 5..30  

dlcLMIUnitLocation 1.3.6.1.4.1.300.200.2.41.1.15
This object configures where the unit is located so that LMI spoofing could be done properly. If 'cpe' is selected, it means the unit is located in Customer Premise. If 'co' is selected, the unit is in Central Office.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER cpe(1), co(2)  

dlcLMIStatus 1.3.6.1.4.1.300.200.2.41.2
OBJECT IDENTIFIER    

dlcSpoofingStatus 1.3.6.1.4.1.300.200.2.41.2.1
This object configures automatic LMI spoofing to the router. 'True' means LMI spoofing will occur automatically, 'False' means it's disabled.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), dte-spoofing(2), net-spoofing(3), dte-and-net-spoofing(4)  

dlcDTEInterfaceLMIStatus 1.3.6.1.4.1.300.200.2.41.2.2
This object indicates the LMI status of DTE interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), lmi-up(2), lmi-down(3)  

dlcNetInterfaceLMIStatus 1.3.6.1.4.1.300.200.2.41.2.3
This object indicates the LMI status of Net interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), lmi-up(2), lmi-down(3)  

dlcInbandDtePort 1.3.6.1.4.1.300.200.2.42
This object configures which DTE port has inband management.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER data1(1), data2(2)  

startTest 1
Sent upon the initiation of a new test condition.
TRAP-TYPE    

endTest 2
Sent upon the termination of a test condition.
TRAP-TYPE    

startAlarm 3
Indicates the beginning of a new alarm condition.
TRAP-TYPE    

endAlarm 4
Indicates the end of an alarm condition.
TRAP-TYPE    

manualConfigChange 5
Generated when the configuration was changed manually on the unit.
TRAP-TYPE