DLINK-EQUIPMENT-MIB

File: DLINK-EQUIPMENT-MIB.mib (11783 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC DLINK-ID-REC-MIB

Imported symbols

NOTIFICATION-TYPE MODULE-IDENTITY OBJECT-TYPE
DateAndTime TruthValue DisplayString
AgentNotifyLevel dlink-common-mgmt

Defined Types

MacAddress  
OCTET STRING Size(6)    

SwPowerEntry  
SEQUENCE    
  swPowerUnitIndex INTEGER
  swPowerID INTEGER
  swPowerStatus INTEGER

SwUnitMgmtEntry  
SEQUENCE    
  swUnitMgmtId INTEGER
  swUnitMgmtMacAddr MacAddress
  swUnitMgmtStartPort INTEGER
  swUnitMgmtPortRange INTEGER
  swUnitMgmtFrontPanelLedStatus OCTET STRING
  swUnitMgmtCtrlMode INTEGER
  swUnitMgmtCurrentMode INTEGER
  swUnitMgmtVersion DisplayString
  swUnitMgmtModuleName DisplayString

Defined Values

swDlinkEquipmentMIB 1.3.6.1.4.1.171.12.11
DLink equipments MIB .
MODULE-IDENTITY    

swDlinkEquipmentMib 1.3.6.1.4.1.171.12.11.1
OBJECT IDENTIFIER    

swDlinkEquipmentNotify 1.3.6.1.4.1.171.12.11.2
OBJECT IDENTIFIER    

swDlinkEquipmentCapacity 1.3.6.1.4.1.171.12.11.1.1
Indicates the equipment capacity supported in the system .
Status: current Access: read-only
OBJECT-TYPE    
  BITS fanCapable(0), redundantPowerCapable(1), tempteratureDetection(2), stackingCapable(3), chassisCapable(4)  

swPowerTable 1.3.6.1.4.1.171.12.11.1.6
A list of temperature.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SwPowerEntry

swPowerEntry 1.3.6.1.4.1.171.12.11.1.6.1
A entry of Power information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SwPowerEntry  

swPowerUnitIndex 1.3.6.1.4.1.171.12.11.1.6.1.1
Indicates ID of the unit in the System
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

swPowerID 1.3.6.1.4.1.171.12.11.1.6.1.2
Indicates ID of the power 1 : main power 2 : redundant power .
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

swPowerStatus 1.3.6.1.4.1.171.12.11.1.6.1.3
Indicates status of the power
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER other(0), lowVoltage(1), overCurrent(2), working(3), fail(4), connect(5), disconnect(6)  

swUnitMgmt 1.3.6.1.4.1.171.12.11.1.9
OBJECT IDENTIFIER    

swUnitStackingVersion 1.3.6.1.4.1.171.12.11.1.9.1
This object indicates the version of this stacking system .
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

swUnitMaxSupportedUnits 1.3.6.1.4.1.171.12.11.1.9.2
Maximum number of units are supported in the system.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

swUnitNumOfUnit 1.3.6.1.4.1.171.12.11.1.9.3
The current number of units.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

swUnitMgmtTable 1.3.6.1.4.1.171.12.11.1.9.4
This table contains the unit information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SwUnitMgmtEntry

swUnitMgmtEntry 1.3.6.1.4.1.171.12.11.1.9.4.1
A list of management information for each unit in the system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SwUnitMgmtEntry  

swUnitMgmtId 1.3.6.1.4.1.171.12.11.1.9.4.1.1
This object indicates the specific entry in the stacking/chassis table.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..15  

swUnitMgmtMacAddr 1.3.6.1.4.1.171.12.11.1.9.4.1.2
The Mac address of this unit.
Status: current Access: read-only
OBJECT-TYPE    
  MacAddress  

swUnitMgmtStartPort 1.3.6.1.4.1.171.12.11.1.9.4.1.3
This object indicates the start port of this unit.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

swUnitMgmtPortRange 1.3.6.1.4.1.171.12.11.1.9.4.1.4
This object indicates the total ports of this unit.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

swUnitMgmtFrontPanelLedStatus 1.3.6.1.4.1.171.12.11.1.9.4.1.5
This object is a set of system LED indications. The first three octets is defined as system LED. The first LED is power LED. The second LED is console LED. The third LED is RPS (Redundancy Power Supply) LED. The other octets following the second octets are the logical port LED (following dot1dBasePort ordering). One byte is presented to one port and this byte is presentd to the Link/Activity LED. Link/Activity LED : The most significant bit is used for blink/solid: 8 = The LED blinks. The second significant bit is used for link status: 1 = link fail. 2 = link pass. The four remaining bits are currently unused and must be 0.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..255)  

swUnitMgmtCtrlMode 1.3.6.1.4.1.171.12.11.1.9.4.1.6
This object indicates the stack mode that user configed for this unit. The object only can be configed when the device is stand alone. other(1) - this entry is currently in use but the conditions under which it will remain so are different from each of the following values. auto(2) - the system will auto assign this stack role of this unit to be stand-alone(3), master(4), or slave(5). stand-alone(3) - the unit is forced to stand alone. master(4) - the unit is forced to master. If this unit is seleted to be master, it can modify the configuration of the stacking system. slave(5) - the unit is forced to slave. If this unit is seleted to be slave, it only can view the configuration of the stacking system.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER other(1), auto(2), stand-alone(3), master(4), slave(5)  

swUnitMgmtCurrentMode 1.3.6.1.4.1.171.12.11.1.9.4.1.7
The current stack role of this unit.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER other(1), auto(2), stand-alone(3), master(4), slave(5)  

swUnitMgmtVersion 1.3.6.1.4.1.171.12.11.1.9.4.1.8
This object indicates the version of this stacking unit.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..32)  

swUnitMgmtModuleName 1.3.6.1.4.1.171.12.11.1.9.4.1.9
A textual string containing module name of the stacking unit.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..32)  

swEquipmentNotification 1.3.6.1.4.1.171.12.11.2.2
OBJECT IDENTIFIER    

swEquipPowerNotification 1.3.6.1.4.1.171.12.11.2.2.2
OBJECT IDENTIFIER    

swEquipPowerNotifyPerfix 1.3.6.1.4.1.171.12.11.2.2.2.0
OBJECT IDENTIFIER    

swPowerFailure 1.3.6.1.4.1.171.12.11.2.2.2.0.2
Power Failure notification.
Status: current Access: read-only
NOTIFICATION-TYPE    

swPowerRecover 1.3.6.1.4.1.171.12.11.2.2.2.0.3
Power Recover notification.
Status: current Access: read-only
NOTIFICATION-TYPE    

swNotificationBindings 1.3.6.1.4.1.171.12.11.2.3
OBJECT IDENTIFIER