DOCS-TEST-MIB

File: DOCS-TEST-MIB.mib (6706 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Integer32
enterprises TEXTUAL-CONVENTION TruthValue
OBJECT-GROUP MODULE-COMPLIANCE

Defined Values

cableLabs 1.3.6.1.4.1.4491
OBJECT IDENTIFIER    

clabFunction 1.3.6.1.4.1.4491.1
OBJECT IDENTIFIER    

clabFuncMib2 1.3.6.1.4.1.4491.1.1
OBJECT IDENTIFIER    

clabFuncProprietary 1.3.6.1.4.1.4491.1.2
OBJECT IDENTIFIER    

clabProject 1.3.6.1.4.1.4491.2
OBJECT IDENTIFIER    

clabProjDocsis 1.3.6.1.4.1.4491.2.1
OBJECT IDENTIFIER    

clabProjPacketCable 1.3.6.1.4.1.4491.2.2
OBJECT IDENTIFIER    

clabProjOpenCable 1.3.6.1.4.1.4491.2.3
OBJECT IDENTIFIER    

clabProjCableHome 1.3.6.1.4.1.4491.2.4
OBJECT IDENTIFIER    

docsTestMIB 1.3.6.1.4.1.4491.2.1.12
This is the MIB Module supporting programmable test features for DOCSIS 2.0 compliant Cable Modems (CM) and Cable Modem Termination Systems (CMTS).
MODULE-IDENTITY    

docsTestMibObjects 1.3.6.1.4.1.4491.2.1.12.1
OBJECT IDENTIFIER    

docsTestBaseObjects 1.3.6.1.4.1.4491.2.1.12.1.1
OBJECT IDENTIFIER    

docsTestSetupObjects 1.3.6.1.4.1.4491.2.1.12.1.2
OBJECT IDENTIFIER    

docsTestCapability 1.3.6.1.4.1.4491.2.1.12.1.1.1
Indicates the ability of this device to support the programmable features identified by the TYPE field from the CM/CMTS TLV table in [17]. Each octet within this octet string represents eight tests. For example, the first octet represents tests one through eight (with the msb representing test one) as identified by the TYPE field.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

docsTestStatus 1.3.6.1.4.1.4491.2.1.12.1.1.2
Indicates the current operating status of tests initiated through the docsTestSetupObjects. The octet representation is identical to that used by docsTestCapability. A bit representation of one indicates that a test is currently active, while zero indicates the test is inactive or has completed.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

docsTestType 1.3.6.1.4.1.4491.2.1.12.1.2.1
Corresponds to the TYPE field from the CM/CMTS TLV Table in [17]. The default value of zero indicates no test has yet been initiated. A WrongValueError should be returned in response to a write request for a test not supported by the device. A read request will return the docsTestType value last successfully written, whether that test is active or inactive.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..1023  

docsTestData 1.3.6.1.4.1.4491.2.1.12.1.2.2
The OCTET STRING length and value correspond to the LENGTH and VALUE fields from the CM/CMTS TLV Table in [17]. A read request will return the docsTestData value last successfully written, whether that test is active or inactive.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

docsTestEnable 1.3.6.1.4.1.4491.2.1.12.1.2.3
Used to initiate or stop the tests setup through the docsTestType and docsTestData objects. A CommitFailedError should be returned in response to a TRUE Write request if the values in docsTestType and docsTestData are incompatible, or a test could not be initiated for any other reason.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

docsTestConformance 1.3.6.1.4.1.4491.2.1.12.2
OBJECT IDENTIFIER    

docsTestCompliances 1.3.6.1.4.1.4491.2.1.12.2.1
OBJECT IDENTIFIER    

docsTestGroups 1.3.6.1.4.1.4491.2.1.12.2.2
OBJECT IDENTIFIER    

docsTestBasicCompliance 1.3.6.1.4.1.4491.2.1.12.2.1.1
The compliance statement for devices that implement the DOCSIS compliant programmable test features.
Status: current Access: read-write
MODULE-COMPLIANCE    

docsTestGroup 1.3.6.1.4.1.4491.2.1.12.2.2.1
Group of objects implemented in both Cable Modems and Cable Modem Termination Systems.
Status: current Access: read-write
OBJECT-GROUP