DOCS-TEST-MIB
File:
DOCS-TEST-MIB.mib (6706 bytes)
Imported modules
Imported symbols
Defined Values
docsTestMIB |
1.3.6.1.4.1.4491.2.1.12 |
This is the MIB Module supporting programmable test features
for DOCSIS 2.0 compliant Cable Modems (CM) and Cable Modem
Termination Systems (CMTS). |
MODULE-IDENTITY |
|
|
|
docsTestCapability |
1.3.6.1.4.1.4491.2.1.12.1.1.1 |
Indicates the ability of this device to support the
programmable features identified by the TYPE field from
the CM/CMTS TLV table in [17].
Each octet within this octet string represents eight tests.
For example, the first octet represents tests one through eight
(with the msb representing test one) as identified by the TYPE
field. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
docsTestStatus |
1.3.6.1.4.1.4491.2.1.12.1.1.2 |
Indicates the current operating status of tests initiated
through the docsTestSetupObjects. The octet representation is
identical to that used by docsTestCapability. A bit representation
of one indicates that a test is currently active, while zero
indicates the test is inactive or has completed. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
docsTestType |
1.3.6.1.4.1.4491.2.1.12.1.2.1 |
Corresponds to the TYPE field from the CM/CMTS TLV Table
in [17]. The default value of zero indicates
no test has yet been initiated.
A WrongValueError should be returned in response to a write
request for a test not supported by the device. A read request
will return the docsTestType value last successfully written,
whether that test is active or inactive. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..1023 |
|
docsTestData |
1.3.6.1.4.1.4491.2.1.12.1.2.2 |
The OCTET STRING length and value correspond to the
LENGTH and VALUE fields from the CM/CMTS TLV
Table in [17]. A read request will return the
docsTestData value last successfully written, whether that test
is active or inactive. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
docsTestEnable |
1.3.6.1.4.1.4491.2.1.12.1.2.3 |
Used to initiate or stop the tests setup through the docsTestType
and docsTestData objects.
A CommitFailedError should be returned in response to a TRUE
Write request if the values in docsTestType and docsTestData are
incompatible, or a test could not be initiated for any other
reason. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
docsTestBasicCompliance |
1.3.6.1.4.1.4491.2.1.12.2.1.1 |
The compliance statement for devices that implement
the DOCSIS compliant programmable test features. |
Status: current |
Access: read-write |
MODULE-COMPLIANCE |
|
|
|
docsTestGroup |
1.3.6.1.4.1.4491.2.1.12.2.2.1 |
Group of objects implemented in both Cable Modems and
Cable Modem Termination Systems. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|