EDB-snmp

File: EDB-snmp.mib (35216 bytes)

Imported modules

RFC-1215 SNMPv2-TC RFC1155-SMI
RFC1213-MIB RFC-1212

Imported symbols

TRAP-TYPE DisplayString mgmt
NetworkAddress IpAddress Counter
Gauge TimeTicks internet
PhysAddress OBJECT-TYPE

Defined Types

RTrapAddrEntry  
SEQUENCE    
  rTrapAddrAddr IpAddress
  rTrapAddrComm OCTET STRING
  rTrapAddrVer INTEGER
  rTrapAddrType OCTET STRING
  rTrapAddrState INTEGER
  rTrapAddrFlag INTEGER
  rTrapAddrAge INTEGER

PTrapAddrEntry  
SEQUENCE    
  pTrapAddrAddr IpAddress
  pTrapAddrComm OCTET STRING
  pTrapAddrVer INTEGER
  pTrapAddrType OCTET STRING
  pTrapAddrState INTEGER

FmSlotEntry  
SEQUENCE    
  fmSlotIndex INTEGER
  fmSlotID INTEGER
  fmSlotDescr OCTET STRING
  fmSlotInfo OCTET STRING
  fmSlotStatus OCTET STRING
  fmSlotPrevStatus OCTET STRING
  fmSlotRLBSet INTEGER
  fmSlotRLBClear INTEGER
  fmSlotExpCode INTEGER
  fmSlotTrapMask INTEGER
  pfmSlotTrapMask INTEGER
  fmSlotIpAddr IpAddress

FmDiagFaultEntry  
SEQUENCE    
  fmDiagFaultIndex INTEGER
  fmDiagFaultReport OCTET STRING

Defined Values

private 1.3.6.1.4
OBJECT IDENTIFIER    

enterprises 1.3.6.1.4.1
OBJECT IDENTIFIER    

fibronics 1.3.6.1.4.1.22
OBJECT IDENTIFIER    

trap 1.3.6.1.4.1.22.3
OBJECT IDENTIFIER    

traprun 1.3.6.1.4.1.22.3.1
OBJECT IDENTIFIER    

traperm 1.3.6.1.4.1.22.3.2
OBJECT IDENTIFIER    

trapvar 1.3.6.1.4.1.22.3.3
OBJECT IDENTIFIER    

fm800 1.3.6.1.4.1.22.51
OBJECT IDENTIFIER    

fmsystem 1.3.6.1.4.1.22.51.1
OBJECT IDENTIFIER    

fmslot 1.3.6.1.4.1.22.51.2
OBJECT IDENTIFIER    

fmlu 1.3.6.1.4.1.22.51.3
OBJECT IDENTIFIER    

fmdiag 1.3.6.1.4.1.22.51.5
OBJECT IDENTIFIER    

fmsystemrun 1.3.6.1.4.1.22.51.1.1
OBJECT IDENTIFIER    

fmsystemperm 1.3.6.1.4.1.22.51.1.2
OBJECT IDENTIFIER    

rTrapAddrTbl 1.3.6.1.4.1.22.3.1.1
Table of managers to which traps must be sent. Up to 10 entries in table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RTrapAddrEntry

rTrapAddrEntry 1.3.6.1.4.1.22.3.1.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  RTrapAddrEntry  

rTrapAddrAddr 1.3.6.1.4.1.22.3.1.1.1.1
IP address of entity requesting event notification
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

rTrapAddrComm 1.3.6.1.4.1.22.3.1.1.1.2
Community name the receiving entity will expect. When reading the instance of this object the value has no meaning.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

rTrapAddrVer 1.3.6.1.4.1.22.3.1.1.1.3
Version number supported by destination node
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

rTrapAddrType 1.3.6.1.4.1.22.3.1.1.1.4
Type of event that should be reported to this address, bit 0 - authentication trap bit 1 - other SNMP traps bit 2 - Error Traps bit 3 - Diagnostic Traps bit 4 - Debug Traps bit 5 - Enterprise Traps other than fmDiagGenericTrap
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

rTrapAddrState 1.3.6.1.4.1.22.3.1.1.1.5
Determines status of this entry
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER active(1), inactive(2)  

rTrapAddrFlag 1.3.6.1.4.1.22.3.1.1.1.6
If the entry is fixed, it can not be deleted because of aging
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER fixed(0), removable(1)  

rTrapAddrAge 1.3.6.1.4.1.22.3.1.1.1.7
Aging time of the entry (in sec)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rTrapLearning 1.3.6.1.4.1.22.3.1.2
Learn the addresses of the managers automatically.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

rTrapAging 1.3.6.1.4.1.22.3.1.3
Time in sec. until we erase a trap entry
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

pTrapAddrTbl 1.3.6.1.4.1.22.3.2.1
Table of managers to which traps must be sent. Up to 10 entries in table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PTrapAddrEntry

pTrapAddrEntry 1.3.6.1.4.1.22.3.2.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PTrapAddrEntry  

pTrapAddrAddr 1.3.6.1.4.1.22.3.2.1.1.1
IP address of entity requesting event notification
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

pTrapAddrComm 1.3.6.1.4.1.22.3.2.1.1.2
Community name the receiving entity will expect. When reading the instance of this object the value has no meaning.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

pTrapAddrVer 1.3.6.1.4.1.22.3.2.1.1.3
Version number supported by destination node
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

pTrapAddrType 1.3.6.1.4.1.22.3.2.1.1.4
Type of event that should be reported to this address, bit 0 - authentication trap bit 1 - other SNMP traps bit 2 - Error Traps bit 3 - Diagnostic Traps bit 4 - Debug Traps bit 5 - all Enterprise Traps other than fmDiagGenericTrap
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

pTrapAddrState 1.3.6.1.4.1.22.3.2.1.1.5
Determines status of this entry
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER active(1), inactive(2)  

pTrapLearning 1.3.6.1.4.1.22.3.2.2
Learn the addresses of the managers automatically.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

pTrapAging 1.3.6.1.4.1.22.3.2.3
Time in sec. until we erase a trap entry
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

fmSystemPSAdmin 1.3.6.1.4.1.22.51.1.1.1
Changes power supply to primary or secondary. When reading the instance of this object the value has no meaning.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER primary-power(1), secondary-power(2)  

fmSystemPSOper 1.3.6.1.4.1.22.51.1.1.2
Which power supply active
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER primary-power(1), secondary-power(2)  

fmSystemPSCfg 1.3.6.1.4.1.22.51.1.1.3
Configuration of power supply
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER primary-power(1), secondary-power(2), primary-and-secondary-power(3)  

fmSystemReset 1.3.6.1.4.1.22.51.1.1.4
Resetting the CARD. When reading the instance of this object the value has no meaning. cold reset is performed with selftest , while warm start is performed without selftest
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER cold-reset(0), warm-reset(1), power-up(2), meaning-less-value(127)  

fmSystemSelfTestLevel 1.3.6.1.4.1.22.51.1.1.5
Type of self test to be executed upon cold-reset
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(0), partial(1), full(2), extended(3)  

fmSystemVersion 1.3.6.1.4.1.22.51.1.1.6
Version of the station. The version includes station type, hardware version and software version. The string can include CR and LF
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

fmSystemIpAddr 1.3.6.1.4.1.22.51.1.1.7
IP address of the agent
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmSystemIPNetMask 1.3.6.1.4.1.22.51.1.1.8
IP Network Mask
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmSystemIPDefGway 1.3.6.1.4.1.22.51.1.1.9
Default Gateway Address
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmSystemFileServer 1.3.6.1.4.1.22.51.1.1.10
IP address to which a TFTP for boot is sent.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

fmSystemBootFile 1.3.6.1.4.1.22.51.1.1.11
Path and file name that is sent as a TFTP request
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

fmSystemBootMode 1.3.6.1.4.1.22.51.1.1.12
Method for booting
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER internal-memory(1), bootp(2)  

fmSystemDownLoad 1.3.6.1.4.1.22.51.1.1.13
Downloading the EDB. When reading the instance of this object the value has no meaning.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER download(1), meaning-less-value(127)  

fmSystemSlipIpAddr 1.3.6.1.4.1.22.51.1.1.14
SLIP IP address. This is object is available only when slip interface exist
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmSystemSlipIPNetMask 1.3.6.1.4.1.22.51.1.1.15
SLIP IP Network Mask This is object is available only when slip interface exist
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmSystemSlipBaudRate 1.3.6.1.4.1.22.51.1.1.16
SLIP Baud rate This is object is available only when slip interface exist
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER baud1200(0), baud2400(1), baud4800(2), baud9600(3), baud19200(4), baud38400(5)  

fmSystemSlipParity 1.3.6.1.4.1.22.51.1.1.17
SLIP Parity This is object is available only when slip interface exist
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(0), odd(1), even(2)  

fmSystemSlipStopBits 1.3.6.1.4.1.22.51.1.1.18
SLIP Stop Bits This is object is available only when slip interface exist
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER one(0), two(1)  

pfmSystemIpAddr 1.3.6.1.4.1.22.51.1.2.7
IP address of the agent
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

pfmSystemIPNetMask 1.3.6.1.4.1.22.51.1.2.8
IP Network Mask
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

pfmSystemIPDefGway 1.3.6.1.4.1.22.51.1.2.9
Default Gateway Address
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

pfmSystemFileServer 1.3.6.1.4.1.22.51.1.2.10
IP address to which a TFTP for boot is sent.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

pfmSystemBootFile 1.3.6.1.4.1.22.51.1.2.11
Path and file name that is sent as a TFTP request
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

pfmSystemBootMode 1.3.6.1.4.1.22.51.1.2.12
Method for booting
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER internal-memory(1), bootp(2)  

pfmSystemReadCommunity 1.3.6.1.4.1.22.51.1.2.13
Community string for reading When reading the instance of this object the value has no meaning.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

pfmSystemWriteCommunity 1.3.6.1.4.1.22.51.1.2.14
Community string for writing When reading the instance of this object the value has no meaning.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

pfmSystemSlipIpAddr 1.3.6.1.4.1.22.51.1.2.15
SLIP IP address This is object is available only when slip interface exist
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

pfmSystemSlipIPNetMask 1.3.6.1.4.1.22.51.1.2.16
SLIP IP Network Mask This is object is available only when slip interface exist
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

pfmSystemSlipBaudRate 1.3.6.1.4.1.22.51.1.2.17
SLIP Baud rate This is object is available only when slip interface exist
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER baud1200(0), baud2400(1), baud4800(2), baud9600(3), baud19200(4), baud38400(5)  

pfmSystemSlipParity 1.3.6.1.4.1.22.51.1.2.18
SLIP Parity This is object is available only when slip interface exist
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(0), odd(1), even(2)  

pfmSystemSlipStopBits 1.3.6.1.4.1.22.51.1.2.19
SLIP Stop Bits This is object is available only when slip interface exist
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER one(0), two(1)  

fmSlotMasterClear 1.3.6.1.4.1.22.51.2.1
Upon writing, performs a master clear command on all the slots. When reading the instance of this object the value has no meaning.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

fmSlotTable 1.3.6.1.4.1.22.51.2.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmSlotEntry

fmSlotEntry 1.3.6.1.4.1.22.51.2.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmSlotEntry  

fmSlotIndex 1.3.6.1.4.1.22.51.2.2.1.1
Slot Number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fmSlotID 1.3.6.1.4.1.22.51.2.2.1.2
ID of the card in the slot
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unconfig(0), empty(1), cc832-10(2), cc832-12(3), cc832-20(4), cc832-31(5), cc832-32(6), cc832-41(7), cc832-42(8), cc832-44(9), cc832-46A(10), cc892-832(65537), lc322(65540), cc892-201(65544), cc892-202(65545), cc892-214(65548), cc892-321(65552), cc892-46B(65553), cc892-301(65560), cc892-303(65562), cc892-308(65563), cc892-233(65568), cc892-260(65576), cc892-427(65580), sw892-11X(65584), cc892-432(65588), cc892-420(65589), cc892-421(65591), cc892-422(65590), cc892-401(65592), cc892-240(65594), cc892-241(65595), cc892-211(65550), cc892-212(65551), lc303(65566), lc308(65567), lc312(65578), cc832-10-ID(65541), cc832-12-ID(65542), cc832-20-ID(65543), cc832-41-ID(65557), cc832-42-ID(65558), cc832-44-ID(65559), general-smartcard(131072), lc308-129(131073), lc303-129(131075), lc312-129(131077)  

fmSlotDescr 1.3.6.1.4.1.22.51.2.2.1.3
Ascii string. Description of the card
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

fmSlotInfo 1.3.6.1.4.1.22.51.2.2.1.4
User general info for the slot. Can be the use of that slot, its location etc...
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

fmSlotStatus 1.3.6.1.4.1.22.51.2.2.1.5
8 bytes. 60 status bits of the card. For more information about the meaning of the status, read the specific user manual of each card. The channel leds are encoded into 2 bytes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

fmSlotPrevStatus 1.3.6.1.4.1.22.51.2.2.1.6
8 bytes. Previous 60 status bits of the card. This object id is used mainly for traps (see Card Trap)
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

fmSlotRLBSet 1.3.6.1.4.1.22.51.2.2.1.7
Argument: 1 - 4. Perform a RLB set operation on the channel passed as argument. When reading the instance of this object the value has no meaning.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

fmSlotRLBClear 1.3.6.1.4.1.22.51.2.2.1.8
Argument: 1 - 4. Perform a RLB clear operation on the channel passed as argument. When reading the instance of this object the value has no meaning.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

fmSlotExpCode 1.3.6.1.4.1.22.51.2.2.1.9
Perform an expanded command on the slot. For expanded codes, see specific card user manual. When reading the instance of this object the value has no meaning. Extended command codes for NDS cards ------------------------------------ 1. CC892.303 (Ethernet) Code (Dec/Hex) Command ----------------------------------- 02/02 Detach Port 13 03/03 Attach Port 13 04/04 Detach Port 01 05/05 Attach Port 01 06/06 Detach Port 02 07/07 Attach Port 02 08/08 Detach Port 03 09/09 Attach Port 03 10/0A Detach Port 04 11/0B Attach Port 04 12/0C Detach Port 05 13/0D Attach Port 05 14/0E Detach Port 06 15/0F Attach Port 06 16/10 Detach Port 07 17/11 Attach Port 07 18/12 Detach Port 08 19/13 Attach Port 08 20/14 Detach Port 09 21/15 Attach Port 09 22/16 Detach Port 10 23/17 Attach Port 10 24/18 Detach Port 11 25/19 Attach Port 11 26/1A Detach Port 12 27/1B Attach Port 12 28/1C Detach All Ports 29/1D Attach All Ports 30/1E Reset Card 31/1F Link Select ====================================================== 2. CC892.308 (Ethernet) Code (Dec/Hex) Command ----------------------------------- 02/02 Detach Port 01 03/03 Attach Port 01 04/04 Detach Port 02 05/05 Attach Port 02 06/06 Detach Port 03 07/07 Attach Port 03 08/08 Detach Port 04 09/09 Attach Port 04 10/0A Detach Port 05 11/0B Attach Port 05 12/0C Detach Port 06 13/0D Attach Port 06 14/0E Detach Port 07 15/0F Attach Port 07 16/10 Detach Port 08 17/11 Attach Port 08 ... 28/1C Detach All Ports 29/1D Attach All Ports 30/1E Reset Card 31/1F Link Select ================================================ 3. CC892.322 (Token-ring) Module 323 ---------- Code (Dec/Hex) Command ----------------------------------- 02/02 Detach Port 01 03/03 Attach Port 01 04/04 Detach Port 02 05/05 Attach Port 02 06/06 Detach Port 03 07/07 Attach Port 03 08/08 Detach Port 04 09/09 Attach Port 04 10/0A Detach Port 05 11/0B Attach Port 05 12/0C Detach Port 06 13/0D Attach Port 06 18/12 Detach Port 07 19/13 Attach Port 07 20/14 Detach Port 08 21/15 Attach Port 08 22/16 Detach Port 19 23/17 Attach Port 19 24/18 Detach Port 10 25/19 Attach Port 10 26/1A Detach Port 11 27/1B Attach Port 11 28/1C Detach Port 12 29/1D Attach Port 12 30/1E Reset Card 34/22 Detach Port 13 35/23 Attach Port 13 36/24 Detach Port 14 37/25 Attach Port 14 38/26 Detach Port 15 39/27 Attach Port 15 40/28 Detach Port 16 41/29 Attach Port 16 42/2A Detach Port 17 43/2B Attach Port 17 44/2C Detach Port 18 45/2D Attach Port 18 50/32 Detach Port 19 51/33 Attach Port 19 52/34 Detach Port 20 53/35 Attach Port 20 54/36 Detach Port 21 55/37 Attach Port 21 56/38 Detach Port 22 57/39 Attach Port 22 58/3A Detach Port 23 59/3B Attach Port 23 60/3C Detach Port 24 61/3D Attach Port 24 77/4D Detach All Ports 79/4F Attach All Ports ======================================================== Module 325 ---------- 30/1E Reset Card 80/50 Detach Local Port 1 (channel 1) 81/51 Attach Local Port 1 (channel 1) 82/52 Detach Local Port 2 (channel 1) 83/53 Attach Local Port 2 (channel 1) 88/58 Detach Local Port 1 (channel 3) 89/59 Attach Local Port 1 (channel 3) 90/5A Detach Local Port 2 (channel 3) 91/5B Attach Local Port 2 (channel 3) 77/4D Detach All Ports 79/4F Attach All Ports 4. CC892.427 (Voice) Code (Dec/Hex) Command ----------------------------------- 04/04 Loopback OFF on Port 1 05/05 Loopback ON on Port 1 06/06 Loopback OFF on Port 2 07/07 Loopback ON on Port 2 08/08 Loopback OFF on Port 3 09/09 Loopback ON on Port 3 10/0A Loopback OFF on Port 4 11/0B Loopback ON on Port 4 12/0C Loopback OFF on Port 5 13/0D Loopback ON on Port 5 14/0E Loopback OFF on Port 6 15/0F Loopback ON on Port 6 16/10 Loopback OFF on Port 7 17/11 Loopback ON on Port 7 18/12 Loopback OFF on Port 8 19/13 Loopback ON on Port 8 20/14 Loopback OFF on Port 9 21/15 Loopback ON on Port 9 22/16 Loopback OFF on Port 10 23/17 Loopback ON on Port 10 24/18 Loopback OFF on Port 11 25/19 Loopback ON on Port 11 26/1A Loopback OFF on Port 12 27/1B Loopback ON on Port 12 28/1C Loopback OFF on Port 13 29/1D Loopback ON on Port 13 30/1E Loopback OFF on Port 14 31/1F Loopback ON on Port 14 32/20 Loopback OFF on Port 15 33/21 Loopback ON on Port 15 34/22 Loopback OFF on Port 16 35/23 Loopback ON on Port 16 37/25 Loopback ALL on Ports 1-8 39/27 Loopback ALL on Ports 9-16 40/28 Alternate Mode on Channel Module #1 41/29 Normal Mode on Channel Module #1 42/2A Alternate Mode on Channel Module #2 43/2B Normal Mode on Channel Module #2 45/2D Configuration Load Module #1 47/2F Configuration Load Module #2 ======================================================
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

fmSlotTrapMask 1.3.6.1.4.1.22.51.2.2.1.10
When the value is 1, no more traps from that slot are sent, until next reset. (temporary mask)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no-mask(0), mask(1)  

pfmSlotTrapMask 1.3.6.1.4.1.22.51.2.2.1.11
When the value is 1, no more traps for that slot will be sent, starting after next reset (permanent mask)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no-mask(0), mask(1)  

fmSlotIpAddr 1.3.6.1.4.1.22.51.2.2.1.12
IP address of a channel card. This is object is available only for channel cards which have their own IP addresses (e.g., LC303/129)
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmLUID 1.3.6.1.4.1.22.51.3.1
Logic unit ID
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unconfig(0), none(1), lu100(2), lu101(3), lu102(4), lu103(5), lu104(6), lu105(7), lu106(8), lu107(9), lu108(10)  

fmLUDescr 1.3.6.1.4.1.22.51.3.2
Ascii string. Description of the logic unit
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

fmLUStatus 1.3.6.1.4.1.22.51.3.3
One byte of LU status
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

fmLULinkSelect 1.3.6.1.4.1.22.51.3.4
Setup LU link.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER main-link(0), sec-link(1)  

fmLULoopBackSet 1.3.6.1.4.1.22.51.3.5
Upon writing, performs LLB command. When reading the instance of this object the value has no meaning.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

fmLULoopBackClr 1.3.6.1.4.1.22.51.3.6
Upon writing, clear LLB command. When reading the instance of this object the value has no meaning.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

fmLUTrapMask 1.3.6.1.4.1.22.51.3.7
When the value is 1, no more traps from the LU are sent, until next reset. (temporary mask)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no-mask(0), mask(1)  

pfmLUTrapMask 1.3.6.1.4.1.22.51.3.8
When the value is 1, no more traps for the LU will be sent, starting after next reset (permanent mask)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no-mask(0), mask(1)  

fmDiagConfig 1.3.6.1.4.1.22.51.5.1
Version of the station. The version includes station type, hardware version and software version. The string can include CR and LF
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

fmDiagTrapInfo 1.3.6.1.4.1.22.51.5.2
Used for generic traps. The first word is the trap code. The rest of the string is the extra information. Contains CR and LF char.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

fmDiagFaultTable 1.3.6.1.4.1.22.51.5.3
Table of fault reports from the agent
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmDiagFaultEntry

fmDiagFaultEntry 1.3.6.1.4.1.22.51.5.3.1
Tok_String
Status: optional Access: not-accessible
OBJECT-TYPE    
  FmDiagFaultEntry  

fmDiagFaultIndex 1.3.6.1.4.1.22.51.5.3.1.1
The fault index in the fault table
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

fmDiagFaultReport 1.3.6.1.4.1.22.51.5.3.1.2
Get the faults detected by the agent
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

fmDiagDebug 1.3.6.1.4.1.22.51.5.4
This object is for factory use only. Users must not write into this variable or improper operation can occur.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal-mode(0), debug-mode(1)  

fmPowerSupplyFail 1
This trap message is generated as soon as one of the power supply has failed
TRAP-TYPE    

fmPrimaryPowerSupplyOK 2
This trap is issued when primary power supply return to work
TRAP-TYPE    

fmSecondPowerSupplyOK 3
This trap is issued when second power supply return to work
TRAP-TYPE    

fmPowerSupplyChangeConfig 4
Issued when a change in the configuration of the power supply is done
TRAP-TYPE    

fmLUOutOfSync 7
Issued when the Logic unit goes out of synchronization
TRAP-TYPE    

fmLUReturnToSync 8
Issues as soon as the logic unit returns to synchronization
TRAP-TYPE    

fmLUPassToMain 9
Issues as soon as the logic unit pass to main link
TRAP-TYPE    

fmLUPassToSecond 10
Issues as soon as the logic unit pass to second link
TRAP-TYPE    

fmLUPrimaryLinkFail 11
When primary link of the logic unit fails this trap is issued
TRAP-TYPE    

fmLUPrimaryLinkOK 12
When primary link of the logic unit fails this trap is issued
TRAP-TYPE    

fmLUSecondLinkFail 13
When second link of the logic unit fails this trap is issued
TRAP-TYPE    

fmLUSecondLinkOK 14
When second link of the logic unit fails this trap is issued
TRAP-TYPE    

fmLULLBOn 15
When the logic unit enters LLB mode
TRAP-TYPE    

fmLULLBOff 16
When the logic unit exits LLB mode
TRAP-TYPE    

fmLUChangeConfig 20
Issues when a change in the LU configuration is done
TRAP-TYPE    

fmSlotTrap 25
Generated when a significant status has changed in a slot. By xoring the 2 statuses, the NMS can identify the cause of the trap.
TRAP-TYPE    

fmSlotChangeConfig 26
Issued when the system detects changes in its slots configuration
TRAP-TYPE    

fmDiagGenericTrap 30
Generic Trap information
TRAP-TYPE