ELS100-S24TX2M-MIB

File: ELS100-S24TX2M-MIB.mib (24325 bytes)

Imported modules

RFC1155-SMI SNMPv2-SMI SNMPv2-TC

Imported symbols

internet MODULE-IDENTITY OBJECT-TYPE
Integer32 IpAddress DisplayString

Defined Types

SwitchInfoEntry  
SEQUENCE    
  swUnitIndex Integer32
  swMainBoardHwVer DisplayString
  swMainBoardFwVer DisplayString
  swAgentBoardHwVer DisplayString
  swAgentBoardFwVer DisplayString
  swAgentBoardPOSTCodeVer DisplayString
  swPortNumber Integer32
  swPowerStatus INTEGER
  swExpansionSlot1 INTEGER
  swExpansionSlot2 INTEGER
  swRoleInSystem INTEGER

SwitchOIDEntry  
SEQUENCE    
  switchOIDIndex INTEGER
  switchOIDValue OBJECT IDENTIFIER

SwitchPortMgtEntry  
SEQUENCE    
  swPortMgtIndex Integer32
  swPortMgtPortType INTEGER
  swPortMgtSpeedDpxAdmin INTEGER
  swPortMgtSpeedDpxInUse INTEGER
  swPortMgtFlowCtrlAdmin INTEGER
  swPortMgtFlowCtrlInUse INTEGER

Defined Values

tpELS100S24TX2M 1.3.6.1.4.1.52.3.9.1.10.7
The MIB module for ELS100-S24TX2M.
MODULE-IDENTITY    

switchInfo 1.3.6.1.4.1.52.3.9.1.10.7.1
OBJECT IDENTIFIER    

switchPortMgt 1.3.6.1.4.1.52.3.9.1.10.7.2
OBJECT IDENTIFIER    

systemSTAMgt 1.3.6.1.4.1.52.3.9.1.10.7.3
OBJECT IDENTIFIER    

tftpDownloadMgt 1.3.6.1.4.1.52.3.9.1.10.7.4
OBJECT IDENTIFIER    

restartMgt 1.3.6.1.4.1.52.3.9.1.10.7.5
OBJECT IDENTIFIER    

portMirrorMgt 1.3.6.1.4.1.52.3.9.1.10.7.6
OBJECT IDENTIFIER    

igmpMgt 1.3.6.1.4.1.52.3.9.1.10.7.7
OBJECT IDENTIFIER    

switchNumber 1.3.6.1.4.1.52.3.9.1.10.7.1.1
The total number of switches present on this system.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

switchInfoTable 1.3.6.1.4.1.52.3.9.1.10.7.1.2
Table of descriptive and status information about switches in this system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SwitchInfoEntry

switchInfoEntry 1.3.6.1.4.1.52.3.9.1.10.7.1.2.1
An entry in the table, containing information about a single switch in this system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SwitchInfoEntry  

swUnitIndex 1.3.6.1.4.1.52.3.9.1.10.7.1.2.1.1
This object identifies the switch within the system for which this entry contains information. This value can never be greater than switchNumber.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

swMainBoardHwVer 1.3.6.1.4.1.52.3.9.1.10.7.1.2.1.2
Hardware version of the main board.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..20)  

swMainBoardFwVer 1.3.6.1.4.1.52.3.9.1.10.7.1.2.1.3
Firmware version of the main board.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..20)  

swAgentBoardHwVer 1.3.6.1.4.1.52.3.9.1.10.7.1.2.1.4
Hardware version of the agent board.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..20)  

swAgentBoardFwVer 1.3.6.1.4.1.52.3.9.1.10.7.1.2.1.5
Firmware version of the agent board.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..20)  

swAgentBoardPOSTCodeVer 1.3.6.1.4.1.52.3.9.1.10.7.1.2.1.6
POST code version of the agent board.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..20)  

swPortNumber 1.3.6.1.4.1.52.3.9.1.10.7.1.2.1.7
The total port number of this switch (including expansion slot).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

swPowerStatus 1.3.6.1.4.1.52.3.9.1.10.7.1.2.1.8
Indicates the switch using internalPower(1), redundantPower(2) or both(3)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER internalPower(1), redundantPower(2), internalAndRedundantPower(3)  

swExpansionSlot1 1.3.6.1.4.1.52.3.9.1.10.7.1.2.1.9
Type of expansion module in this switch slot 1.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER hundredBaseFX2Port(1), thousandBaseSX(2), stackingModule4GB(3), hundredBaseFX1Port(4), thousandBaseLX(5), thousandBaseT(6), thousandBaseGBIC(7), stackingModule2GB(8), other(9), notPresent(10)  

swExpansionSlot2 1.3.6.1.4.1.52.3.9.1.10.7.1.2.1.10
Type of expansion module in this switch slot 2.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER hundredBaseFX2Port(1), thousandBaseSX(2), stackingModule4GB(3), hundredBaseFX1Port(4), thousandBaseLX(5), thousandBaseT(6), thousandBaseGBIC(7), stackingModule2GB(8), other(9), notPresent(10)  

swRoleInSystem 1.3.6.1.4.1.52.3.9.1.10.7.1.2.1.11
Indicates the switch is master(1), backupMaster(2) or slave(3) in this system.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER master(1), backupMaster(2), slave(3)  

switchOIDTable 1.3.6.1.4.1.52.3.9.1.10.7.1.3
Table of System Object Identifiers for switches in this system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SwitchOIDEntry

switchOIDEntry 1.3.6.1.4.1.52.3.9.1.10.7.1.3.1
An entry in the table, containing System Object Identifier for a single switch in this system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SwitchOIDEntry  

switchOIDIndex 1.3.6.1.4.1.52.3.9.1.10.7.1.3.1.1
This object identifies the switch within the system for which this entry contains information. This value can never be greater than switchNumber. Index value 1 always represents the Master in a stacked configuration and the only device in a standalone configuration. Subsequent indices are sequential with the lowest number representing the Slave nearest the Master and so on.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..65535  

switchOIDValue 1.3.6.1.4.1.52.3.9.1.10.7.1.3.1.2
This object contains the System Object Identifier that uniquely identifies the type of switch.
Status: current Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

switchPortMgtTable 1.3.6.1.4.1.52.3.9.1.10.7.2.1
Table of descriptive and status information about configuration of each switch ports (including expansion slot) in this system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SwitchPortMgtEntry

switchPortMgtEntry 1.3.6.1.4.1.52.3.9.1.10.7.2.1.1
An entry in the table, containing information about configuration in one switch port of the switch.
Status: current Access: not-accessible
OBJECT-TYPE    
  SwitchPortMgtEntry  

swPortMgtIndex 1.3.6.1.4.1.52.3.9.1.10.7.2.1.1.1
This object identifies the port within the switch for which this entry contains information.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

swPortMgtPortType 1.3.6.1.4.1.52.3.9.1.10.7.2.1.1.2
Indicates the port type is tenBaseT/hundredBaseTX(1), hundredBaseFX(2) or thousandBaseSX(3).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER hundredBaseTX(1), hundredBaseFX(2), thousandBaseSX(3)  

swPortMgtSpeedDpxAdmin 1.3.6.1.4.1.52.3.9.1.10.7.2.1.1.3
Set the port speed and duplex mode as follows: halfDuplex10(1) - 10Mbps and half duplex mode fullDuplex10(2) - 10Mbps and full duplex mode halfDuplex100(3) - 100Mbps and half duplex mode fullDuplex100(4) - 100Mbps and full duplex mode halfDuplex1000(5) - 1000Mbps and half duplex mode fullDuplex1000(6) - 1000Mbps and full duplex mode autoNegotiation(7) - let the switch to negotiate with the other end of connection. hundredBaseTX port can be set as halfDuplex10(1) fullDuplex10(2) halfDuplex100(3) fullDuplex100(4) autoNegotiation(7) hundredBaseFX port can be set as halfDuplex100(3) fullDuplex100(4) thousandBaseSX port can be set as halfDuplex1000(5) fullDuplex1000(6) autoNegotiation(7) The actual operating speed and duplex of the port is given by swPortMgtSpeedDpxInUse.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER halfDuplex10(1), fullDuplex10(2), halfDuplex100(3), fullDuplex100(4), halfDuplex1000(5), fullDuplex1000(6), autoNegotiation(7)  

swPortMgtSpeedDpxInUse 1.3.6.1.4.1.52.3.9.1.10.7.2.1.1.4
The operating speed and duplex mode of the switched port.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER halfDuplex10(1), fullDuplex10(2), halfDuplex100(3), fullDuplex100(4), halfDuplex1000(5), fullDuplex1000(6)  

swPortMgtFlowCtrlAdmin 1.3.6.1.4.1.52.3.9.1.10.7.2.1.1.5
(1) Flow control mechanism is enabled. If the port type is hundredBaseTX or thousandBaseSX: When the port is operating in halfDuplex mode, the port uses backPressure flow control mechanism. When the port is operating in fullDuplex mode, the port uses IEEE 802.3x flow control mechanism. If the port type is hundredBaseFX: When the port is operating in halfDuplex mode, the port uses backPressure flow control mechanism. When the port is operating in fullDuplex mode, Flow control mechanism will not function. (2) Flow control mechanism is disabled. (3) Flow control mechanism is backPressure. When the port is in fullDuplex mode this flow control mechanism will not function. (4) Flow control mechanism is IEEE 802.3x flow control. When the port is in halfDuplex mode this flow control mechanism will not function. hundredBaseTX and thousandBaseSX port can be set as: enabled(1), disabled(2), backPressure(3), dot3xFlowControl(4). hundredBaseFX port can be set as: enabled(1), disabled(2), backPressure(3). The actual flow control mechanism is used given by swPortMgtFlowCtrlInUse.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), backPressure(3), dot3xFlowControl(4)  

swPortMgtFlowCtrlInUse 1.3.6.1.4.1.52.3.9.1.10.7.2.1.1.6
(1) BackPressure flow control mechanism is used. (2) IEEE 802.3 flow control mechanism is used. (3) Flow control mechanism is disabled.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER backPressure(1), dot3xFlowControl(2), none(3)  

systemSTAStatus 1.3.6.1.4.1.52.3.9.1.10.7.3.1
Global spanning tree status. (1) Spanning tree protocol is enabled. (2) Spanning tree protocol is disabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

tftpDownloadServerIP 1.3.6.1.4.1.52.3.9.1.10.7.4.1
The IP address of a TFTP server from which a firmware image can be downloaded.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

tftpDownloadAgentBoardFwFileName 1.3.6.1.4.1.52.3.9.1.10.7.4.2
Tok_String
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..80)  

tftpDownloadAgentBoardFwDownloadNode 1.3.6.1.4.1.52.3.9.1.10.7.4.3
Indicates whether a newly upgraded firmware version should write to flash. When this object is temporary(2), following a successful upgrade the system will switch to run the new firmware but will not upgrade the new firmware to flash. That means after a power cycle, system will run the firmware residing the flash. When this object is permanent(1), following a successful firmware upgrade, the flash will be upgraded and the system will automatically switch to run the new firmware.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER permanent(1), temporary(2)  

tftpDownloadStatus 1.3.6.1.4.1.52.3.9.1.10.7.4.4
Setting this object to active(1) trigger the TFTP download action. Setting this object to notActive(2) has no effect. The system always returns the value notActive(2) when this object is read.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER active(1), notActive(2)  

restartOptionPOST 1.3.6.1.4.1.52.3.9.1.10.7.5.1
Setting this object as enabled. The system will do POST when it restart
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

restartOptionReloadFactoryDefault 1.3.6.1.4.1.52.3.9.1.10.7.5.2
Setting this object as enabled. The system will do factory reset when it restart
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

restartOptionKeepIpSetting 1.3.6.1.4.1.52.3.9.1.10.7.5.3
Setting this object as enabled. The system will keep IP setting when it do factory reset.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

restartOptionKeepUserAuthentication 1.3.6.1.4.1.52.3.9.1.10.7.5.4
Setting this object as enabled. The system will keep user authentication setting when it do factory reset.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

restartAction 1.3.6.1.4.1.52.3.9.1.10.7.5.5
Setting this object to active(1) trigger the system restart. Setting this object to notActive(2) has no effect. The system always returns the value notActive(2) when this object is read.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER active(1), notActive(2)  

portMirrorStatus 1.3.6.1.4.1.52.3.9.1.10.7.6.1
Port mirroring function status. (1) mirroring function is enabled. (2) mirroring function is disabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

portMirrorSnifferPort 1.3.6.1.4.1.52.3.9.1.10.7.6.2
Linear port number of sniffer port to which all frames to/from mirrored ports are sent. Frames are only mirrored if the portMirrorStatus object is set to enabled(1).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

portMirrorMirroredPort 1.3.6.1.4.1.52.3.9.1.10.7.6.3
Linear port number of mirrored port. The traffic of mirrored port will be 'copied' to sniffer port.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

igmpStatus 1.3.6.1.4.1.52.3.9.1.10.7.7.1
Parameter to enable or disable IGMP snooping on the device. When enabled, the device will examine IGMP packets and set up filters for IGMP ports. The default is enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

igmpQueryCount 1.3.6.1.4.1.52.3.9.1.10.7.7.2
Maximum number of queries that have not been heard on the system before the system starts taking action to solicit reports(default is 5).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 2..16  

igmpReportDelay 1.3.6.1.4.1.52.3.9.1.10.7.7.3
Timeout value(mins) between IGMP reports received on a port for an IP Multicast Address that can pass before the system sends an IGMP Query out the port and removes it from the list(default is 5 minutes).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 3..10