ETHERNET-MIB

File: ETHERNET-MIB.mib (9009 bytes)

Imported modules

SNMPv2-SMI SNMPv2-CONF SNMPv2-TC
ExaltComm ExaltComProducts

Imported symbols

MODULE-IDENTITY OBJECT-TYPE OBJECT-IDENTITY
Gauge32 Integer32 OBJECT-GROUP
DisplayString TEXTUAL-CONVENTION AlarmLevelT
EnableStatusT EthernetMgmtTypeT interface
locEthAlarms remEthAlarms

Defined Types

EthernetFunctionT  
The ethernet port function status
TEXTUAL-CONVENTION    
  INTEGER traffic(0), mgmt(1), trafficmgmt(2)  

EthernetModeT  
The Ethernet port operation modes
TEXTUAL-CONVENTION    
  INTEGER full1000(0), half1000(1), full100(2), half100(3), full10(4), half10(5), auto(6)  

EthRateLimitTypeT  
The ethernet rate limit type in KBPS (or) MBPS.
TEXTUAL-CONVENTION    
  INTEGER kbps(0), mbps(1)  

EthRateLimitValueT  
The ethernet rate limit, if the rate limit is enabled, the value is applied on to the port. eg., rate in KBPS (64..1792, stepsize 64) rate in MBPS (2..100, stepsize 1) and (104..1000, stepsize 8)
TEXTUAL-CONVENTION    
  Integer32  

EthernetPortEntry  
SEQUENCE    
  function EthernetFunctionT
  mode EthernetModeT
  alarm EnableStatusT
  mute EnableStatusT
  dhcp EnableStatusT
  rateConfig EnableStatusT
  rateType EthRateLimitTypeT
  rateLimit EthRateLimitValueT

LocalEthAlarmsEntry  
SEQUENCE    
  locEthAlarm AlarmLevelT

RemoteEthAlarmsEntry  
SEQUENCE    
  remEthAlarm AlarmLevelT

Defined Values

ethernet 1.3.6.1.4.1.25651.1.2.3.2.1
Ethernet interfaces.
Status: current Access: read-only
OBJECT-IDENTITY    

ethernetNumChannels 1.3.6.1.4.1.25651.1.2.3.2.1.3
The maximum number of available ethernet channels.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethernetInterfaces 1.3.6.1.4.1.25651.1.2.3.2.1.4
Attributes for ethernet ports.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EthernetPortEntry

ethernetInterface 1.3.6.1.4.1.25651.1.2.3.2.1.4.1
An entry in the Ethernet table.
Status: current Access: not-accessible
OBJECT-TYPE    
  EthernetPortEntry  

function 1.3.6.1.4.1.25651.1.2.3.2.1.4.1.1
Ethernet port function.
Status: current Access: read-write
OBJECT-TYPE    
  EthernetFunctionT  

mode 1.3.6.1.4.1.25651.1.2.3.2.1.4.1.2
Ethernet mode .
Status: current Access: read-write
OBJECT-TYPE    
  EthernetModeT  

alarm 1.3.6.1.4.1.25651.1.2.3.2.1.4.1.3
Ethernet port alarm.
Status: current Access: read-write
OBJECT-TYPE    
  EnableStatusT  

mute 1.3.6.1.4.1.25651.1.2.3.2.1.4.1.4
Ethernet can be muted, when there is a system/ethernet alarm. When MHS is enabled, the ethernet mute is termed as 'Auto', setting a value as 2, when MHS disabled, the value is restored
Status: current Access: read-write
OBJECT-TYPE    
  EnableStatusT  

rateConfig 1.3.6.1.4.1.25651.1.2.3.2.1.4.1.5
Ethernet rate limit status, default is disabled
Status: current Access: read-write
OBJECT-TYPE    
  EnableStatusT  

rateType 1.3.6.1.4.1.25651.1.2.3.2.1.4.1.6
Ethernet rate limit type, default is KBPS
Status: current Access: read-write
OBJECT-TYPE    
  EthRateLimitTypeT  

rateLimit 1.3.6.1.4.1.25651.1.2.3.2.1.4.1.7
Ethernet rate limit type default is 64KBPS
Status: current Access: read-write
OBJECT-TYPE    
  EthRateLimitValueT  

dhcp 1.3.6.1.4.1.25651.1.2.3.2.1.4.1.8
DHCP (Enable/Disable) on port.
Status: current Access: read-write
OBJECT-TYPE    
  EnableStatusT  

ethernetLearning 1.3.6.1.4.1.25651.1.2.3.2.1.5
Etherner Learning (Enable/Disable) on the switch
Status: current Access: read-write
OBJECT-TYPE    
  EnableStatusT  

ethernetMgmt 1.3.6.1.4.1.25651.1.2.3.2.1.6
Etherner Management Type (Inband/Out-of-Band/Port-to-Port/Legacy) for the switch
Status: current Access: read-write
OBJECT-TYPE    
  EthernetMgmtTypeT  

ethernetFlowControl 1.3.6.1.4.1.25651.1.2.3.2.1.7
Etherner Flow Control (Disable/Enable) on the switch
Status: current Access: read-write
OBJECT-TYPE    
  EnableStatusT  

commitEthernetSettings 1.3.6.1.4.1.25651.1.2.3.2.1.1000
The Commit ethernet command.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(4..200)  

locETHAlarms 1.3.6.1.4.1.25651.1.2.4.2.3.2.1
The Local Ethernet Interface Alarms.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LocalEthAlarmsEntry

locEthAlarmsEntry 1.3.6.1.4.1.25651.1.2.4.2.3.2.1.1
Ethernet Alarms table Entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  LocalEthAlarmsEntry  

locEthAlarm 1.3.6.1.4.1.25651.1.2.4.2.3.2.1.1.1
The Alarms state for the Local Ethernet Channel.
Status: current Access: read-only
OBJECT-TYPE    
  AlarmLevelT  

remETHAlarms 1.3.6.1.4.1.25651.1.2.4.2.4.2.1
The Local Ethernet Interface Alarms.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RemoteEthAlarmsEntry

remEthAlarmsEntry 1.3.6.1.4.1.25651.1.2.4.2.4.2.1.1
Ethernet Alarms table Entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  RemoteEthAlarmsEntry  

remEthAlarm 1.3.6.1.4.1.25651.1.2.4.2.4.2.1.1.1
The Alarms state for the Remote Ethernet Channel.
Status: current Access: read-only
OBJECT-TYPE    
  AlarmLevelT