Defined Types

FsPortDefEntry  
SEQUENCE    
  fsPortDefLogPortNo INTEGER
  fsPortDefPhyBoardNo INTEGER
  fsPortDefPhyPortNo INTEGER
  fsPortDefProtocol INTEGER
  fsPortDefStatus INTEGER

FsPortDialupConfigEntry  
SEQUENCE    
  fsPortDialupLogPortNo INTEGER
  fsPortDialupDialMode INTEGER
  fsPortDialupPrimaryPhe DisplayString
  fsPortDialupSecondPhe DisplayString
  fsPortDialupRedialTimer INTEGER
  fsPortDialupNumRedial INTEGER
  fsPortDialupDialPortPri INTEGER
  fsPortDialupTollSaver INTEGER
  fsPortDialupTollSaverTimeout INTEGER
  fsPortDialupMaxNumSucCalls INTEGER
  fsPortDialupLocalTel INTEGER
  fsPortDialISDNDataRate INTEGER
  fsPortDialStatus INTEGER

FsFrameRelayDefEntry  
SEQUENCE    
  fsFrameRelayPortNo INTEGER
  fsFrameRelaySpeed INTEGER
  fsFrameRelayProtocol INTEGER
  fsFrameRelayN1 INTEGER
  fsFrameRelayN2 INTEGER
  fsFrameRelayN3 INTEGER
  fsFrameRelayT1 INTEGER
  fsFrameRelayT2 INTEGER
  fsFrameRelayPriEnable INTEGER
  fsFrameRelayPriHiToMed INTEGER
  fsFrameRelayPriMedToLow INTEGER
  fsFrameRelayStatus INTEGER

FsFrameRelayPriDlciEntry  
SEQUENCE    
  fsFRPriPortNo INTEGER
  fsFRPriIndex INTEGER
  fsFRPriDlciNum INTEGER
  fsFRPriDlciCIR INTEGER
  fsFRPriDlciBc INTEGER
  fsFRPriDlciBe INTEGER
  fsFRPriStatus INTEGER

FsAsyncEncapDefEntry  
SEQUENCE    
  fsAsyncEncapPortNo INTEGER
  fsAsyncEncapSpeed INTEGER
  fsAsyncEncapDataBits INTEGER
  fsAsyncEncapParity INTEGER
  fsAsyncEncapStopBits INTEGER
  fsAsyncEncapPri INTEGER
  fsAsyncEncapDestinationPort INTEGER
  fsAsyncEncapBreakLength INTEGER
  fsAsyncEncapGptName DisplayString
  fsAsyncEncapStatus INTEGER

FsBitSyncEncapDefEntry  
SEQUENCE    
  fsBitSyncEncapPortNo INTEGER
  fsBitSyncEncapSpeed INTEGER
  fsBitSyncEncapFormat INTEGER
  fsBitSyncEncapSwitchedDcd INTEGER
  fsBitSyncEncapIdleMark INTEGER
  fsBitSyncEncapPri INTEGER
  fsBitSyncEncapGptName DisplayString
  fsBitSyncEncapStatus INTEGER

FsSlipDefEntry  
SEQUENCE    
  fsSlipPortNo INTEGER
  fsSlipSpeed INTEGER
  fsSlipStatus INTEGER

FsAsyncBurosEmulateDefEntry  
SEQUENCE    
  fsAsyncBurosEmulatePortNo INTEGER
  fsAsyncBurosEmulateSpeed INTEGER
  fsAsyncBurosEmulateType INTEGER
  fsAsyncBurosEmulateResTimeout INTEGER
  fsAsyncBurosEmulateCtsDelay INTEGER
  fsAsyncBurosEmulateStatus INTEGER

FsAsyncBurosEntry  
SEQUENCE    
  fsAsyncBurosPortNo INTEGER
  fsAsyncBurosIndex INTEGER
  fsAsyncBurosLocalLogicalId INTEGER
  fsAsyncBurosLocalDeviceAddr DisplayString
  fsAsyncBurosLocalGroupAddr DisplayString
  fsAsyncBurosRemoteIPaddr IpAddress
  fsAsyncBurosRemoteLogicalId INTEGER
  fsAsyncBurosStatus INTEGER

FsSyncBurosEmulateDefEntry  
SEQUENCE    
  fsSyncBurosEmulatePortNo INTEGER
  fsSyncBurosEmulateSpeed INTEGER
  fsSyncBurosEmulateType INTEGER
  fsSyncBurosEmulateResTimeout INTEGER
  fsSyncBurosEmulateCtsDelay INTEGER
  fsSyncBurosEmulateStatus INTEGER

FsSyncBurosEntry  
SEQUENCE    
  fsSyncBurosPortNo INTEGER
  fsSyncBurosIndex INTEGER
  fsSyncBurosLocalLogicalId INTEGER
  fsSyncBurosLocalDeviceAddr DisplayString
  fsSyncBurosLocalGroupAddr DisplayString
  fsSyncBurosRemoteIPaddr IpAddress
  fsSyncBurosRemoteLogicalId INTEGER
  fsSyncBurosStatus INTEGER

FsSdlcRouteDefEntry  
SEQUENCE    
  fsSdlcRoutePortNo INTEGER
  fsSdlcRouteSpeed INTEGER
  fsSdlcRouteFormat INTEGER
  fsSdlcRouteSwitchedDcd INTEGER
  fsSdlcRouteIdleMark INTEGER
  fsSdlcRouteStatus INTEGER

FsSdlcRouteConEntry  
SEQUENCE    
  fsSdlcRouteConPortNo INTEGER
  fsSdlcRouteConIndex INTEGER
  fsSdlcRouteConAddr DisplayString
  fsSdlcRouteGptName DisplayString
  fsSdlcRouteConPri INTEGER
  fsSdlcRouteConStatus INTEGER

FsByteSyncEncapDefEntry  
SEQUENCE    
  fsByteSyncEncapPortNo INTEGER
  fsByteSyncEncapSpeed INTEGER
  fsByteSyncEncapPri INTEGER
  fsByteSyncEncapDestinationPort INTEGER
  fsByteSyncEncapCode INTEGER
  fsByteSyncEncapGptName DisplayString
  fsByteSyncEncapStatus INTEGER

FsTelnetTermDefEntry  
SEQUENCE    
  fsTelnetTermPortNo INTEGER
  fsTelnetTermSpeed INTEGER
  fsTelnetTermDataBits INTEGER
  fsTelnetTermParity INTEGER
  fsTelnetTermStopBits INTEGER
  fsTelnetTermFlowControl INTEGER
  fsTelnetTermFCType INTEGER
  fsTelnetTermConnectionType INTEGER
  fsTelnetTermAnswerMode INTEGER
  fsTelnetTermDataMode INTEGER
  fsTelnetTermNullMode INTEGER
  fsTelnetTermQuietMode INTEGER
  fsTelnetTermLocalEcho INTEGER
  fsTelnetTermRemoteEcho INTEGER
  fsTelnetTermForceDTR INTEGER
  fsTelnetTermForceDCD INTEGER
  fsTelnetTermForceDSR INTEGER
  fsTelnetTermLocalTCP INTEGER
  fsTelnetTermRemoteTCP INTEGER
  fsTelnetTermRemoteIP IpAddress
  fsTelnetTermXpadLogPort INTEGER
  fsTelnetTermStatus INTEGER

FsALCDefEntry  
SEQUENCE    
  fsALCPortNo INTEGER
  fsALCSpeed INTEGER
  fsALCPollTime INTEGER
  fsALCTimeOut INTEGER
  fsALCControllerIA DisplayString
  fsALCControllerIPAddr IpAddress
  fsALCRemoteHostIPAddr IpAddress
  fsALCESDIPAddr IpAddress
  fsALCStatus INTEGER

FsSDLC2DefEntry  
SEQUENCE    
  fsSDLC2PortNo INTEGER
  fsSDLC2Speed INTEGER
  fsSDLC2PollType INTEGER
  fsSDLC2DataFmt INTEGER
  fsSDLC2IdleMark INTEGER
  fsSDLC2DCD INTEGER
  fsSDLC2UserBuffHigh INTEGER
  fsSDLC2UserBuffLow INTEGER
  fsSDLC2Status INTEGER

FsSDLC2StnEntry  
SEQUENCE    
  fsSDLC2StnPortNo INTEGER
  fsSDLC2StnIndex INTEGER
  fsSDLC2StnAddr DisplayString
  fsSDLC2DuplexMode INTEGER
  fsSDLC2StnRWindow INTEGER
  fsSDLC2StnXWindow INTEGER
  fsSDLC2InactTimer INTEGER
  fsSDLC2AckTimer INTEGER
  fsSDLC2MaxRetries INTEGER
  fsSDLC2StnStatus INTEGER

FsX25NEWL1DefEntry  
SEQUENCE    
  fsX25NEWL1PortNo INTEGER
  fsX25NEWL1Speed INTEGER
  fsX25NEWL1GptName DisplayString
  fsX25NEWL1Status INTEGER

FsX25NEWL2DefEntry  
SEQUENCE    
  fsX25NEWL2PortNo INTEGER
  fsX25NEWL2Mode INTEGER
  fsX25NEWL2LinkActivator INTEGER
  fsX25NEWL2T1AckTimer INTEGER
  fsX25NEWL2T2ResTimer INTEGER
  fsX25NEWL2T3DisconnectTimer INTEGER
  fsX25NEWL2N2RetryCount INTEGER
  fsX25NEWL2Sequence INTEGER
  fsX25NEWL2RxKWindowSize INTEGER
  fsX25NEWL2TxKWindowSize INTEGER
  fsX25NEWL2Status INTEGER

FsX25NEWL3DefEntry  
SEQUENCE    
  fsX25NEWL3PortNo INTEGER
  fsX25NEWL3Mode INTEGER
  fsX25NEWL3TxPacketSize INTEGER
  fsX25NEWL3RxPacketSize INTEGER
  fsX25NEWL3Sequencing INTEGER
  fsX25NEWL3TxWindowSize INTEGER
  fsX25NEWL3RxWindowSize INTEGER
  fsX25NEWL3RestartTimer INTEGER
  fsX25NEWL3CallTimer INTEGER
  fsX25NEWL3ResetTimer INTEGER
  fsX25NEWL3ClearTimer INTEGER
  fsX25NEWL3InputCallFacOpt INTEGER
  fsX25NEWL3OutputCallFacOpt INTEGER
  fsX25NEWL3HPVC INTEGER
  fsX25NEWL3LSVC INTEGER
  fsX25NEWL3HSVC INTEGER
  fsX25NEWL3MaxActiveVC INTEGER
  fsX25NEWL3Status INTEGER

FsXPADDefEntry  
SEQUENCE    
  fsXPADPortNo INTEGER
  fsXPADX3Speed INTEGER
  fsXPADDataBits INTEGER
  fsXPADStopBits INTEGER
  fsXPADFlowControl INTEGER
  fsXPADFlowConType INTEGER
  fsXPADSubAddr DisplayString
  fsXPADAllowMnemonics INTEGER
  fsXPADIdleVCTmr INTEGER
  fsXPADX3ProfileSelect INTEGER
  fsXPADTelLogPort INTEGER
  fsXPADStatus INTEGER

FsXPADProfile1Entry  
SEQUENCE    
  fsXPADPro1PortNo INTEGER
  fsXPADX3RecallChar INTEGER
  fsXPADX3EchoEnable INTEGER
  fsXPADX3DataFwdChar INTEGER
  fsXPADX3IdleTmr INTEGER
  fsXPADX3ANCDevCtrl INTEGER
  fsXPADX3PSSCtrl INTEGER
  fsXPADX3ActOnBreak INTEGER
  fsXPADX3DiscardOutput INTEGER
  fsXPADX3CRPadding INTEGER
  fsXPADX3LineFolding INTEGER
  fsXPADPro1Status INTEGER

FsXPADProfile2Entry  
SEQUENCE    
  fsXPADPro2PortNo INTEGER
  fsXPADX3FlowCtrl INTEGER
  fsXPADX3LFAfterCR INTEGER
  fsXPADX3LFPadding INTEGER
  fsXPADX3Editing INTEGER
  fsXPADX3CharDelChar INTEGER
  fsXPADX3LineDelChar INTEGER
  fsXPADX3LineDisplayChar INTEGER
  fsXPADX3EditingPSS INTEGER
  fsXPADX3EchoMask INTEGER
  fsXPADX3Parity INTEGER
  fsXPADX3PageWait INTEGER
  fsXPADPro2Status INTEGER

FsPPPNewDefEntry  
SEQUENCE    
  fsPPPNewPortNo INTEGER
  fsPPPNewType INTEGER
  fsPPPNewSpeed INTEGER
  fsPPPNewLQM INTEGER
  fsPPPNewLQMPert INTEGER
  fsPPPNewLQMTimer INTEGER
  fsPPPNewIPXNetNumber DisplayString
  fsPPPNewNodeNumber DisplayString
  fsPPPNewSapMode INTEGER
  fsPPPNewLCPMRU INTEGER
  fsPPPNewAddrNegoSel INTEGER
  fsPPPNewAddrNego IpAddress
  fsPPPNewLocalUserName DisplayString
  fsPPPNewLocalPasswd DisplayString
  fsPPPNewAuthProtocol INTEGER
  fsPPPNewStatus INTEGER

FsPPPNewRemoteUserEntry  
SEQUENCE    
  fsPPPRemotePortNo INTEGER
  fsPPPRemoteIndex INTEGER
  fsPPPRemoteName DisplayString
  fsPPPRemotePasswd DisplayString
  fsPPPRemoteStatus INTEGER

FsPPPMLinkDefEntry  
SEQUENCE    
  fsPPPMLinkPortNo INTEGER
  fsPPPMLinkIPXNetNumber DisplayString
  fsPPPMLinkNodeNumber DisplayString
  fsPPPMLinkSapMode INTEGER
  fsPPPMLinkMRRU INTEGER
  fsPPPMLinkMPHeader INTEGER
  fsPPPMLinkAddrNegoSel INTEGER
  fsPPPMLinkAddrNego IpAddress
  fsPPPMLinkLocalUserName DisplayString
  fsPPPMLinkLocalPasswd DisplayString
  fsPPPMLinkAuthProtocol INTEGER
  fsPPPMLinkStatus INTEGER

FsPPPMLinkMemberEntry  
SEQUENCE    
  fsPPPMemberPortNo INTEGER
  fsPPPMemberIndex INTEGER
  fsPPPMemberPort INTEGER
  fsPPPMemberStatus INTEGER

FsPPPMLinkRemoteUserEntry  
SEQUENCE    
  fsPPPMLRemotePortNo INTEGER
  fsPPPMLRemoteIndex INTEGER
  fsPPPMLRemoteName DisplayString
  fsPPPMLRemotePasswd DisplayString
  fsPPPMLRemoteStatus INTEGER

FsInterDefEntry  
SEQUENCE    
  fsInterfacePortNo INTEGER
  fsInterfaceType INTEGER
  fsInterfaceDesc DisplayString

FsPortE1DefEntry  
SEQUENCE    
  fsPortE1PortNo INTEGER
  fsPortE1DsuFrameFormat INTEGER
  fsPortE1DsuCRC INTEGER
  fsPortE1LineBuildout INTEGER
  fsPortE1DsuClock INTEGER
  fsPortE1DsuTimeSlots DisplayString
  fsPortE1DsuDataType INTEGER
  fsPortE1DsuDisFrame INTEGER
  fsPortE1DsuAISTrans INTEGER
  fsPortE1DsuLineLoop INTEGER
  fsPortE1ChannelMode INTEGER
  fsPortE1Channel64KRate DisplayString
  fsPortE1Channel56KRate DisplayString
  fsPortE1Channel48KRate DisplayString
  fsPortE1ConfigStatus INTEGER

FsPortT1DefEntry  
SEQUENCE    
  fsPortT1PortNo INTEGER
  fsPortT1DsuFrameFormat INTEGER
  fsPortT1DsuLineCode INTEGER
  fsPortT1DsuBitStuffing INTEGER
  fsPortT1DsuLineBuildOut INTEGER
  fsPortT1DsuGSTACKLineBuildOut INTEGER
  fsPortT1DsuClock INTEGER
  fsPortT1DsuLineLoopBack INTEGER
  fsPortT1DsuLocAnalog INTEGER
  fsPortT1DsuLocDigital INTEGER
  fsPortT1DsuRemAnalog INTEGER
  fsPortT1DsuRemDigital INTEGER
  fsPortT1DsuTimeSlotDataRate INTEGER
  fsPortT1DsuTimeSlots DisplayString
  fsPortT1DsuTimeSlotDataType INTEGER
  fsPortT1DsuYellowAlarm INTEGER
  fsPortT1ChannelMode INTEGER
  fsPortT1Channel64KRate DisplayString
  fsPortT1Channel56KRate DisplayString
  fsPortT1Channel48KRate DisplayString
  fsPortT1ConfigStatus INTEGER

FsPortSerialDefEntry  
SEQUENCE    
  fsPortSerialPortNo INTEGER
  fsPortSerialDteDceMode INTEGER
  fsPortSerialConfigStatus INTEGER

FsPortDT1E1ConfigEntry  
SEQUENCE    
  fsPortDT1E1ConfigPortNo INTEGER
  fsPortDT1E1ConfigPort1LineBuildout INTEGER
  fsPortDT1E1ConfigPort2LineBuildout INTEGER
  fsPortDT1E1ConfigPort1Clock INTEGER
  fsPortDT1E1ConfigPort2Clock INTEGER
  fsPortDT1E1ConfigPort1TimeSlot DisplayString
  fsPortDT1E1ConfigPort2TimeSlot DisplayString
  fsPortDT1E1ConfigPortType INTEGER
  fsPortDT1E1ConfigChannelMode INTEGER
  fsPortDT1E1ConfigChannel64KRate DisplayString
  fsPortDT1E1ConfigChannel56KRate DisplayString
  fsPortDT1E1ConfigChannel48KRate DisplayString
  fsPortDT1E1ConfigTimingRef INTEGER
  fsPortDT1E1ConfigTDMClockRate INTEGER
  fsPortDT1E1ConfigStatus INTEGER
  fsPortDT1E1ConfigPort1IdleABCDBits DisplayString
  fsPortDT1E1ConfigPort2IdleABCDBits DisplayString
  fsPortDT1E1ConfigPort1SeizeABCDBits DisplayString
  fsPortDT1E1ConfigPort2SeizeABCDBits DisplayString

FsPortDT1E1CrossConnEntry  
SEQUENCE    
  fsPortDT1E1CrossConnPortNo INTEGER
  fsPortDT1E1CrossConnSys-Port1 DisplayString
  fsPortDT1E1CrossConnSys-Port2 DisplayString
  fsPortDT1E1CrossConnPort1-Sys DisplayString
  fsPortDT1E1CrossConnPort1-Port2 DisplayString
  fsPortDT1E1CrossConnPort2-Sys DisplayString
  fsPortDT1E1CrossConnPort2-Port1 DisplayString
  fsPortDT1E1CrossConnStatus INTEGER

Defined Values

fsPortDefinition 2.1.10.1
OBJECT IDENTIFIER    

fsFrameRelay 2.1.10.2
OBJECT IDENTIFIER    

fsAsyncEncapsulation 2.1.10.3
OBJECT IDENTIFIER    

fsBitSyncEncapsulation 2.1.10.4
OBJECT IDENTIFIER    

fsSLIP 2.1.10.7
OBJECT IDENTIFIER    

fsAsyncBurosEmulation 2.1.10.9
OBJECT IDENTIFIER    

fsSyncBurosEmulation 2.1.10.10
OBJECT IDENTIFIER    

fsSdlcRoute 2.1.10.11
OBJECT IDENTIFIER    

fsByteSyncEncapsulation 2.1.10.12
OBJECT IDENTIFIER    

fsTelnetTerminal 2.1.10.13
OBJECT IDENTIFIER    

fsALC 2.1.10.16
OBJECT IDENTIFIER    

fsSDLC2 2.1.10.20
OBJECT IDENTIFIER    

fsX25NEW 2.1.10.21
OBJECT IDENTIFIER    

fsXPAD 2.1.10.22
OBJECT IDENTIFIER    

fsPPPNew 2.1.10.23
OBJECT IDENTIFIER    


fsEtherNet 2.1.10.25
OBJECT IDENTIFIER    

fsTokenRing 2.1.10.26
OBJECT IDENTIFIER    

fsInterfaceDefinition 2.1.11.1
OBJECT IDENTIFIER    

fsInterfaceE1 2.1.11.2
OBJECT IDENTIFIER    

fsInterfaceT1 2.1.11.3
OBJECT IDENTIFIER    

fsInterfaceVoice 2.1.11.4
OBJECT IDENTIFIER    

fsInterfaceSerial 2.1.11.5
OBJECT IDENTIFIER    

fsInterfaceSDSL 2.1.11.6
OBJECT IDENTIFIER    

fsInterfaceDT1E1 2.1.11.7
OBJECT IDENTIFIER    

fsPortDefTable 2.1.10.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FsPortDefEntry

fsPortDefEntry 2.1.10.1.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FsPortDefEntry  

fsPortDefLogPortNo 2.1.10.1.1.1.1
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER portN(1), port1(2), port2(3), port3(4), port4(5), portE(6), port10(10), port11(11), port12(12), port13(13), port14(14), port15(15), port16(16), port17(17), port18(18), port19(19), port20(20), port21(21), port22(22), port23(23), port24(24), port25(25), port26(26), port27(27), port28(28), port29(29)  

fsPortDefPhyBoardNo 2.1.10.1.1.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER master(0), board1(1), board2(2), board3(3), board4(4), board5(5), board6(6), board7(7), board8(8), board9(9), board10(10), board11(11), board12(12), board13(13), board14(14), undefined(100)  

fsPortDefPhyPortNo 2.1.10.1.1.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER portS(0), portN(1), port1(2), port2(3), port3(4), port4(5), portE(6), undefined(100)  

fsPortDefProtocol 2.1.10.1.1.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER undefined(0), frameRelay(2), asyncEncapsu(3), bitSyncEncapsu(4), slip(5), asyncBurEmulation(11), syncBurEmulation(12), sdlcRouting(16), byteSyncEncapsu(20), etherNet(21), telnetTerminal(24), alc(25), token(26), sdlc2(32), x25New(33), xPad(34), pPPNew(39), mLP(42)  

fsPortDefStatus 2.1.10.1.1.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER view(1), modify(2)  

fsPortDialupConfigTable 2.1.10.1.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FsPortDialupConfigEntry

fsPortDialupConfigEntry 2.1.10.1.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FsPortDefEntry  

fsPortDialupLogPortNo 2.1.10.1.2.1.1
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER portN(1), port1(2), port2(3), port3(4), port4(5), port10(10), port11(11), port12(12), port13(13), port14(14), port15(15), port16(16), port17(17), port18(18), port19(19), port20(20), port21(21), port22(22), port23(23), port24(24), port25(25), port26(26), port27(27), port28(28), port29(29)  

fsPortDialupDialMode 2.1.10.1.2.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dIALOUT(1), aNSWER(2), iNVALID(100)  

fsPortDialupPrimaryPhe 2.1.10.1.2.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(16)  

fsPortDialupSecondPhe 2.1.10.1.2.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(16)  

fsPortDialupRedialTimer 2.1.10.1.2.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..180  

fsPortDialupNumRedial 2.1.10.1.2.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..99  

fsPortDialupDialPortPri 2.1.10.1.2.1.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER lOW(1), mEDIUM(2), hIGH(3)  

fsPortDialupTollSaver 2.1.10.1.2.1.8
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER eNABLED(1), dISABLED(2)  

fsPortDialupTollSaverTimeout 2.1.10.1.2.1.9
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..600  

fsPortDialupMaxNumSucCalls 2.1.10.1.2.1.10
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..25  

fsPortDialupLocalTel 2.1.10.1.2.1.11
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER local-Tel-1(1), local-Tel-2(2), invalid(3)  

fsPortDialISDNDataRate 2.1.10.1.2.1.12
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER rate-56K(1), rate-64K(2), invalid(3)  

fsPortDialStatus 2.1.10.1.2.1.13
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER view(1), modify(2)  

fsFrameRelayDefTable 2.1.10.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FsFrameRelayDefEntry

fsFrameRelayDefEntry 2.1.10.2.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FsFrameRelayDefEntry  

fsFrameRelayPortNo 2.1.10.2.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER portN(1), port1(2), port2(3), port3(4), port4(5), port10(10), port11(11), port12(12), port13(13), port14(14), port15(15), port16(16), port17(17), port18(18), port19(19), port20(20), port21(21), port22(22), port23(23), port24(24), port25(25), port26(26), port27(27), port28(28), port29(29)  

fsFrameRelaySpeed 2.1.10.2.1.1.2
The sync speed the FRAD will provide/accept clock to/from the network
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER external(0), baud002400(1), baud004800(2), baud009600(3), baud019200(4), baud038400(5), baud048000(6), baud056000(7), baud064000(8), baud096000(9), baud128000(10), baud192000(11), baud256000(12), baud384000(13), baud512000(14), baud768000(15), baud102400(16), baud204800(17)  

fsFrameRelayProtocol 2.1.10.2.1.1.3
Select the type of Frame Relay management protocol to use on the port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER lmiNet(0), lmiUser(1), annexdNet(2), annexdUser(3), annexaNet(4), annexaUser(5), adaptMgmtUser(6), adaptMgmtNet(7), none(8)  

fsFrameRelayN1 2.1.10.2.1.1.4
The STATUS_ENQUIRY message typically is a request for the Sequence Number Exchange Only (report type= 00000001). Every N1 polling intervals the user device requests a Full Status Message (report type= 00000000).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

fsFrameRelayN2 2.1.10.2.1.1.5
Value N2 is the number of error events that must be detected in the last N3 events in order for the link to be considered down.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..10  

fsFrameRelayN3 2.1.10.2.1.1.6
Value N3 is the number of events in which N2 errors must be detected for the link to be considered down. It is also the number of events that must occur with no N2 errors in order for the link to be considered back up.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..10  

fsFrameRelayT1 2.1.10.2.1.1.7
T1 is the length of the time spent waiting for a STATUS message after sending STATUS_ENQUIRY (user devices).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 5..30  

fsFrameRelayT2 2.1.10.2.1.1.8
T2 is the time the network will spend waiting for a STATUS_ENQUIRY from user devices.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 5..30  

fsFrameRelayPriEnable 2.1.10.2.1.1.9
Enable priority queuing for the port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

fsFrameRelayPriHiToMed 2.1.10.2.1.1.10
This is the ratio of number of bytes sent for High priority data to Medium priority data.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER by1to1(0), by2to1(1), by4to1(2), by8to1(3), by16to1(4), by32to1(5), by64to1(6)  

fsFrameRelayPriMedToLow 2.1.10.2.1.1.11
This is the ratio of number of bytes sent for Medium priority data to Low priority data.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER by1to1(0), by2to1(1), by4to1(2), by8to1(3), by16to1(4), by32to1(5), by64to1(6)  

fsFrameRelayStatus 2.1.10.2.1.1.12
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER view(1), modify(2)  

fsFrameRelayPriDlciTable 2.1.10.2.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FsFrameRelayPriDlciEntry

fsFrameRelayPriDlciEntry 2.1.10.2.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FsFrameRelayPriDlciEntry  

fsFRPriPortNo 2.1.10.2.2.1.1
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER portN(1), port1(2), port2(3), port3(4), port4(5), port10(10), port11(11), port12(12), port13(13), port14(14), port15(15), port16(16), port17(17), port18(18), port19(19), port20(20), port21(21), port22(22), port23(23), port24(24), port25(25), port26(26), port27(27), port28(28), port29(29)  

fsFRPriIndex 2.1.10.2.2.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

fsFRPriDlciNum 2.1.10.2.2.1.3
This is the DLCI to use for the data.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

fsFRPriDlciCIR 2.1.10.2.2.1.4
This is the CIR for the DLCI.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

fsFRPriDlciBc 2.1.10.2.2.1.5
This is the committed burst rate for the PVC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

fsFRPriDlciBe 2.1.10.2.2.1.6
This is the excess burst rate to use for the PVC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

fsFRPriStatus 2.1.10.2.2.1.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER view(1), add(2), delete(3), modify(4)  

fsAsyncEncapDefTable 2.1.10.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FsAsyncEncapDefEntry

fsAsyncEncapDefEntry 2.1.10.3.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FsAsyncEncapDefEntry  

fsAsyncEncapPortNo 2.1.10.3.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER portN(1), port1(2), port2(3), port3(4), port4(5), port10(10), port11(11), port12(12), port13(13), port14(14), port15(15), port16(16), port17(17), port18(18), port19(19), port20(20), port21(21), port22(22), port23(23), port24(24), port25(25), port26(26), port27(27), port28(28), port29(29)  

fsAsyncEncapSpeed 2.1.10.3.1.1.2
The async speed of the user's equipment
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER baud001200(1), baud002400(2), baud004800(3), baud009600(4), baud019200(5), baud038400(6), baud048000(7), baud057600(8), baud115200(9)  

fsAsyncEncapDataBits 2.1.10.3.1.1.3
The number of bits in the data bytes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER sevenBits(7), eightBits(8)  

fsAsyncEncapParity 2.1.10.3.1.1.4
The type of parity used for the data.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER oddParity(0), evenParity(1), markParity(2), spaceParity(3), noParity(4)  

fsAsyncEncapStopBits 2.1.10.3.1.1.5
The number of stop bits to use for the data.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER oneBit(1), twoBits(2)  

fsAsyncEncapPri 2.1.10.3.1.1.6
The priority setting for the data (immediate, high, medium, low).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER immediate(0), high(1), medium(2), low(3)  

fsAsyncEncapDestinationPort 2.1.10.3.1.1.7
The destination port of the remote FRAD.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER portNet-port16(1), port1(2), port2(3), port3(4), port4(5), port5(6), port6(7), port7(8), port8(9), port9(10), port10(11), port11(12), port12(13), port13(14), port14(15), port15(16)  

fsAsyncEncapBreakLength 2.1.10.3.1.1.8
Set the length of a break character.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER length-200ms(1), length-400ms(2), length-600ms(3), length-800ms(4), length-1000ms(5)  

fsAsyncEncapGptName 2.1.10.3.1.1.9
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(11)  

fsAsyncEncapStatus 2.1.10.3.1.1.10
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER view(1), modify(2)  

fsBitSyncEncapDefTable 2.1.10.4.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FsBitSyncEncapDefEntry

fsBitSyncEncapDefEntry 2.1.10.4.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FsBitSyncEncapDefEntry  

fsBitSyncEncapPortNo 2.1.10.4.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER portN(1), port1(2), port2(3), port3(4), port4(5), port10(10), port11(11), port12(12), port13(13), port14(14), port15(15), port16(16), port17(17), port18(18), port19(19), port20(20), port21(21), port22(22), port23(23), port24(24), port25(25), port26(26), port27(27), port28(28), port29(29)  

fsBitSyncEncapSpeed 2.1.10.4.1.1.2
The sync speed the FRAD will provide/accept clock to/from the user's equipment
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER external(0), baud002400(1), baud004800(2), baud009600(3), baud019200(4), baud038400(5), baud048000(6), baud056000(7), baud064000(8), baud096000(9), baud128000(10), baud192000(11), baud256000(12), baud384000(13), baud512000(14), baud768000(15), baud1024000(16)  

fsBitSyncEncapFormat 2.1.10.4.1.1.3
The format of the HDLC frame (NRZ, NRZI).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER nrz(1), nrzi(2)  

fsBitSyncEncapSwitchedDcd 2.1.10.4.1.1.4
Switched DCD is usually used for AS400 users in order to simulate the functionality of a multipoint network.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER switched(1), forced(2)  

fsBitSyncEncapIdleMark 2.1.10.4.1.1.5
SDLC device use different filler characters in between actual data packets. Select either 'mark' or flag (7E).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER mark(1), flag(2)  

fsBitSyncEncapPri 2.1.10.4.1.1.6
Priority setting for the data (immediate, high, medium, low).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER immediate(0), high(1), medium(2), low(3)  

fsBitSyncEncapGptName 2.1.10.4.1.1.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(11)  

fsBitSyncEncapStatus 2.1.10.4.1.1.8
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER view(1), modify(2)  

fsSlipDefTable 2.1.10.7.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FsSlipDefEntry

fsSlipDefEntry 2.1.10.7.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FsSlipDefEntry  

fsSlipPortNo 2.1.10.7.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER portN(1), port1(2), port2(3), port3(4), port4(5), port10(10), port11(11), port12(12), port13(13), port14(14), port15(15), port16(16), port17(17), port18(18), port19(19), port20(20), port21(21), port22(22), port23(23), port24(24), port25(25), port26(26), port27(27), port28(28), port29(29)  

fsSlipSpeed 2.1.10.7.1.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER baud001200(1), baud002400(2), baud004800(3), baud009600(4), baud019200(5), baud038400(6), baud048000(7), baud057600(8), baud115200(9)  

fsSlipStatus 2.1.10.7.1.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER view(1), modify(2)  

fsAsyncBurosEmulateDefTable 2.1.10.9.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FsAsyncBurosEmulateDefEntry

fsAsyncBurosEmulateDefEntry 2.1.10.9.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FsAsyncBurosEmulateDefEntry  

fsAsyncBurosEmulatePortNo 2.1.10.9.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER portN(1), port1(2), port2(3), port3(4), port4(5), port10(10), port11(11), port12(12), port13(13), port14(14), port15(15), port16(16), port17(17), port18(18), port19(19), port20(20), port21(21), port22(22), port23(23), port24(24), port25(25), port26(26), port27(27), port28(28), port29(29)  

fsAsyncBurosEmulateSpeed 2.1.10.9.1.1.2
The sync speed the FRAD will provide/accept clock to/from the user's equipment
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER baud001200(1), baud002400(2), baud004800(3), baud009600(4), baud019200(5), baud038400(6), baud048000(7), baud057600(8), baud115200(9)  

fsAsyncBurosEmulateType 2.1.10.9.1.1.3
The Asynchronous Burroughs parameters allows you to set the Polling Emulation Type. The FRAD port must be configured as either Host or Terminal, depending on which device is connected to the port. If the FRAD port you are configuring is connected to a Host, type '1'. If it is connected to a Terminal, type '2'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER hostEnd(1), terminalEnd(2)  

fsAsyncBurosEmulateResTimeout 2.1.10.9.1.1.4
Asynchronous Burroughs parameters allows you to set the Terminal Timer. The default is three seconds. This timer needs to be set only if you selected Terminal as the Polling Emulation Type.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

fsAsyncBurosEmulateCtsDelay 2.1.10.9.1.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

fsAsyncBurosEmulateStatus 2.1.10.9.1.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER view(1), modify(2)  

fsAsyncBurosTable 2.1.10.9.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FsAsyncBurosEntry

fsAsyncBurosEntry 2.1.10.9.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FsAsyncBurosEntry  

fsAsyncBurosPortNo 2.1.10.9.2.1.1
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER portN(1), port1(2), port2(3), port3(4), port4(5), port10(10), port11(11), port12(12), port13(13), port14(14), port15(15), port16(16), port17(17), port18(18), port19(19), port20(20), port21(21), port22(22), port23(23), port24(24), port25(25), port26(26), port27(27), port28(28), port29(29)  

fsAsyncBurosIndex 2.1.10.9.2.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fsAsyncBurosLocalLogicalId 2.1.10.9.2.1.3
The FRAD transfers data between logical units. This means that the FRAD doesn't deal with real controllers but maps real controllers to artificial logical units. This is done so that the FRAD can, for example, map a real control unit that has address C1 onto a controller that is known to the host as D2. In this way point-to-point terminals at one end of the network can be made to appear as a multi-dropped line to the host. The Local Logical ID number is the unique identifying number in the FRAD that is then mapped through this table to a real controller.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..99  

fsAsyncBurosLocalDeviceAddr 2.1.10.9.2.1.4
This is the address of either a physical controller to be polled if the FRAD port is configured for terminal or a controller for which the FRAD will answer if the FRAD port is configured for Host.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..4)  

fsAsyncBurosLocalGroupAddr 2.1.10.9.2.1.5
Controllers (terminals) in Burroughs Poll/Select can be referred to by a group address. When a group address is used in a poll, any terminal in that group is permitted to respond.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..4)  

fsAsyncBurosRemoteIPaddr 2.1.10.9.2.1.6
This is the IP address of the device that will receive messages sent from this FRAD port. Every FRAD has an IP address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

fsAsyncBurosRemoteLogicalId 2.1.10.9.2.1.7
- This is the logical ID of the remote device which will receive messages sent from this FRAD port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..99  

fsAsyncBurosStatus 2.1.10.9.2.1.8
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER view(1), add(2), delete(3), modify(4)  

fsSyncBurosEmulateDefTable 2.1.10.10.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FsSyncBurosEmulateDefEntry

fsSyncBurosEmulateDefEntry 2.1.10.10.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FsSyncBurosEmulateDefEntry  

fsSyncBurosEmulatePortNo 2.1.10.10.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER portN(1), port1(2), port2(3), port3(4), port4(5), port10(10), port11(11), port12(12), port13(13), port14(14), port15(15), port16(16), port17(17), port18(18), port19(19), port20(20), port21(21), port22(22), port23(23), port24(24), port25(25), port26(26), port27(27), port28(28), port29(29)  

fsSyncBurosEmulateSpeed 2.1.10.10.1.1.2
The sync speed the FRAD will provide/accept clock to/from the user's equipment
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER external(0), baud002400(1), baud004800(2), baud009600(3), baud019200(4), baud038400(5), baud048000(6), baud056000(7), baud064000(8), baud096000(9), baud128000(10), baud192000(11), baud256000(12), baud384000(13), baud512000(14), baud768000(15), baud1024000(16)  

fsSyncBurosEmulateType 2.1.10.10.1.1.3
If the FRAD port you are configuring is connected to a Host, type '1'. If it is connected to a Terminal, type '2'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER hostEnd(1), terminalEnd(2)  

fsSyncBurosEmulateResTimeout 2.1.10.10.1.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

fsSyncBurosEmulateCtsDelay 2.1.10.10.1.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

fsSyncBurosEmulateStatus 2.1.10.10.1.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER view(1), modify(2)  

fsSyncBurosTable 2.1.10.10.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FsSyncBurosEntry

fsSyncBurosEntry 2.1.10.10.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FsSyncBurosEntry  

fsSyncBurosPortNo 2.1.10.10.2.1.1
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER portN(1), port1(2), port2(3), port3(4), port4(5), port10(10), port11(11), port12(12), port13(13), port14(14), port15(15), port16(16), port17(17), port18(18), port19(19), port20(20), port21(21), port22(22), port23(23), port24(24), port25(25), port26(26), port27(27), port28(28), port29(29)  

fsSyncBurosIndex 2.1.10.10.2.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fsSyncBurosLocalLogicalId 2.1.10.10.2.1.3
The FRAD transfers data between logical units. This means that the FRAD doesn't deal with real controllers but maps real controllers to artificial logical units. This is done so that the FRAD can, for example, map a real control unit at a site that may have an address of C1 onto a controller that is known to the host as D2. In this way point-to-point terminals at one end of the network can be made to appear as a multi-dropped line to the host. The Local Logical ID number is the unique identifying number in the FRAD that is then mapped through this table to a real controller.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..99  

fsSyncBurosLocalDeviceAddr 2.1.10.10.2.1.4
This is the address of either a physical controller to be polled if the FRAD port is configured for terminal or a controller for which the FRAD will answer if the FRAD port is configured for Host.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..4)  

fsSyncBurosLocalGroupAddr 2.1.10.10.2.1.5
If you have selected 'Host' for the Polling Emulation Type, the Local Logical ID option will reappear. You can either add more addresses or press to exit. If you exit, you will see a list of the addresses which have been entered and be given the option to add, modify or delete.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..4)  

fsSyncBurosRemoteIPaddr 2.1.10.10.2.1.6
This is the IP address of the device that will receive messages sent from this FRAD port. Every FRAD has an IP address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

fsSyncBurosRemoteLogicalId 2.1.10.10.2.1.7
- This is the logical ID of the remote device which will receive messages sent from this FRAD port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..99  

fsSyncBurosStatus 2.1.10.10.2.1.8
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER view(1), add(2), delete(3), modify(4)  

fsSdlcRouteDefTable 2.1.10.11.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FsSdlcRouteDefEntry

fsSdlcRouteDefEntry 2.1.10.11.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FsSdlcRouteDefEntry  

fsSdlcRoutePortNo 2.1.10.11.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER portN(1), port1(2), port2(3), port3(4), port4(5), port10(10), port11(11), port12(12), port13(13), port14(14), port15(15), port16(16), port17(17), port18(18), port19(19), port20(20), port21(21), port22(22), port23(23), port24(24), port25(25), port26(26), port27(27), port28(28), port29(29)  

fsSdlcRouteSpeed 2.1.10.11.1.1.2
The sync speed the FRAD will provide/accept clock to/from the user's equipment
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER external(0), baud002400(1), baud004800(2), baud009600(3), baud019200(4), baud038400(5), baud048000(6), baud056000(7), baud064000(8), baud096000(9), baud128000(10), baud192000(11), baud256000(12), baud384000(13), baud512000(14), baud768000(15), baud1024000(16)  

fsSdlcRouteFormat 2.1.10.11.1.1.3
The SDLC Routing parameters allows you to set the Data Format. There are two data formats: Non-Return-to-Zero (NRZ) and Non-Return-to-Zero Inverted (NRZI). Check your equipment specifications to determine which you are using
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER nrz(1), nrzi(2)  

fsSdlcRouteSwitchedDcd 2.1.10.11.1.1.4
The SDLC Routing Parameters menu allows you to determine when DCD will be active. It is only effective on ports set up as DCE interfaces. If DCD is set to Switched, DCD will only be active during data transmission from the FRAD. If set to Forced, DCD will remain active at all times. The default for this parameter is Forced. (Prior to implementation of this option, a DCE port would raise DCD and keep it active at all times.)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER switched(1), forced(2)  

fsSdlcRouteIdleMark 2.1.10.11.1.1.5
Idle Character on the SDLC Routing Parameters menu allows you to select transmission of Mark characters between frames, except after frames whose Poll/Final (P/F) bit is clear (off). Normally, an HDLC protocol transmits HDLC Flag (0x7e with no zero insertion) characters between frames. If Idle Character is set to Flag, the FRAD will continue to issue HDLC Flag characters in the idle state. If Idle Character is set to Mark, the FRAD will send solid Mark characters (all binary ones) in the idle state. The exception is that any frame which does not have the P/F flag of the command byte set (bit 0x10 of the second byte of the frame) will be followed by HDLC Flag characters. (This exception was explicitly designed for compatibility with IBM AS400s. However, it does reflect the actual state of an HDLC line over half-duplex modems.) The default for this parameter is Flag.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER mark(1), flag(2)  

fsSdlcRouteStatus 2.1.10.11.1.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER view(1), modify(2)  

fsSdlcRouteConTable 2.1.10.11.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FsSdlcRouteConEntry

fsSdlcRouteConEntry 2.1.10.11.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FsSdlcRouteConEntry  

fsSdlcRouteConPortNo 2.1.10.11.2.1.1
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER portN(1), port1(2), port2(3), port3(4), port4(5), port10(10), port11(11), port12(12), port13(13), port14(14), port15(15), port16(16), port17(17), port18(18), port19(19), port20(20), port21(21), port22(22), port23(23), port24(24), port25(25), port26(26), port27(27), port28(28), port29(29)  

fsSdlcRouteConIndex 2.1.10.11.2.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fsSdlcRouteConAddr 2.1.10.11.2.1.3
Type the SDLC controller address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..2)  

fsSdlcRouteGptName 2.1.10.11.2.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..12)  

fsSdlcRouteConPri 2.1.10.11.2.1.5
Enter the priority level of the data.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER immediate(0), high(1), medium(2), low(3)  

fsSdlcRouteConStatus 2.1.10.11.2.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER view(1), add(2), delete(3), modify(4)  

fsByteSyncEncapDefTable 2.1.10.12.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FsByteSyncEncapDefEntry

fsByteSyncEncapDefEntry 2.1.10.12.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FsByteSyncEncapDefEntry  

fsByteSyncEncapPortNo 2.1.10.12.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER portN(1), port1(2), port2(3), port3(4), port4(5), port10(10), port11(11), port12(12), port13(13), port14(14), port15(15), port16(16), port17(17), port18(18), port19(19), port20(20), port21(21), port22(22), port23(23), port24(24), port25(25), port26(26), port27(27), port28(28), port29(29)  

fsByteSyncEncapSpeed 2.1.10.12.1.1.2
The sync speed the FRAD will provide/accept clock to/from the user's equipment
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER external(0), baud002400(1), baud004800(2), baud009600(3), baud019200(4), baud038400(5), baud048000(6), baud056000(7), baud064000(8), baud096000(9), baud128000(10), baud192000(11), baud256000(12), baud384000(13), baud512000(14), baud768000(15), baud1024000(16)  

fsByteSyncEncapPri 2.1.10.12.1.1.3
Select the data's priority level.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER immediate(0), high(1), medium(2), low(3)  

fsByteSyncEncapDestinationPort 2.1.10.12.1.1.4
Select the destination port of the remote FRAD.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER portNet-port16(1), port1(2), port2(3), port3(4), port4(5), port5(6), port6(7), port7(8), port8(9), port9(10), port10(11), port11(12), port12(13), port13(14), port14(15), port15(16)  

fsByteSyncEncapCode 2.1.10.12.1.1.5
Select the code set to use.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ascii(1), ebcdic(2)  

fsByteSyncEncapGptName 2.1.10.12.1.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(11)  

fsByteSyncEncapStatus 2.1.10.12.1.1.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER view(1), modify(2)  

fsTelnetTermDefTable 2.1.10.13.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FsTelnetTermDefEntry

fsTelnetTermDefEntry 2.1.10.13.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FsTelnetTermDefEntry  

fsTelnetTermPortNo 2.1.10.13.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER portN(1), port1(2), port2(3), port3(4), port4(5), port10(10), port11(11), port12(12), port13(13), port14(14), port15(15), port16(16), port17(17), port18(18), port19(19), port20(20), port21(21), port22(22), port23(23), port24(24), port25(25), port26(26), port27(27), port28(28), port29(29)  

fsTelnetTermSpeed 2.1.10.13.1.1.2
The async speed of the user's equipment
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER baud001200(1), baud002400(2), baud004800(3), baud009600(4), baud019200(5), baud038400(6), baud048000(7), baud057600(8), baud115200(9)  

fsTelnetTermDataBits 2.1.10.13.1.1.3
Select the number of data bits.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER sevenBits(7), eightBits(8)  

fsTelnetTermParity 2.1.10.13.1.1.4
Select the parity to be used.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER oddParity(1), evenParity(2), markParity(3), spaceParity(4), noParity(5)  

fsTelnetTermStopBits 2.1.10.13.1.1.5
Select the number of stop bits.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER oneBit(1), twoBits(2)  

fsTelnetTermFlowControl 2.1.10.13.1.1.6
Flow control can be enabled for transmit only, receive only or both directions for either of the two Flow Control Types.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), txOnly(2), rxOnly(3), on(4)  

fsTelnetTermFCType 2.1.10.13.1.1.7
Select the type of flow control. Both RTS/CTS hardware flow control and XON/XOFF software flow control are supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER rtsCts(1), xonXoff(2)  

fsTelnetTermConnectionType 2.1.10.13.1.1.8
This parameter determines how the Telnet Client terminal will initiate a connection with the Telnet Server. You can select Manual connection or DTR Dial. In the manual mode, you manually enter an IP Address to connect to a Telnet Server by using the Telnet Terminal Commands Menu (see Section 5.16.19) on the local terminal. This menu can also be used to PING a remote Server. Pressing 'X' will end the Telnet session. It can also be terminated from the remote end. In the DTR dial mode, Telnet Terminal will initiate a Telnet connection to a remote Telnet Server immediately after the port's DTR is enabled. The remote TCP port and remote IP address configured in the Telnet Terminal Parameters menu will be used to make the connection. The connection is closed when DTR is off. Note that DTR can be forced on as described above.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER manual(1), dtrDial(2)  

fsTelnetTermAnswerMode 2.1.10.13.1.1.9
This parameter allows you to set the port to act as a Telnet Server by turning on the Answer Mode. The port will then respond to Telnet Clients attempting to make a connection. If the Answer Mode is off, the port will not answer Telnet calls.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fsTelnetTermDataMode 2.1.10.13.1.1.10
This parameter allows you to set the Data Mode. There are two modes: normal and binary. The Normal data mode uses 'Control X' as an escape character. It allows parameter handshaking after connection. The binary data mode is in accordance with RFC 856. When in Binary Data mode, the only available method for dropping a connection is to drop the DTR control signal on either end of the connection. (Note that dropping DTR drops the connection in Normal mode as well.) The default for this parameter is Normal.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), binary(2)  

fsTelnetTermNullMode 2.1.10.13.1.1.11
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), disable(2)  

fsTelnetTermQuietMode 2.1.10.13.1.1.12
When the Telnet Module Connection Type is configured as 'Manual' and there is no active Telnet session on a given port, the Telnet Command menu will be displayed on the associated terminal. Quiet Mode allows you to disable this display. This capability is useful if a host machine or computer connected to the Telnet port does not tolerate the menu characters being received from the Telnet port. The default for this option is Off.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2)  

fsTelnetTermLocalEcho 2.1.10.13.1.1.13
Local Echo is a straight forward mechanism for displaying data which can be configured in the FRAD by an On, Off or Auto selection. The Local Echo option has three possible settings. If it is enabled, the FRAD will always echo characters received from the terminal back to the terminal. If Local Echo is disabled, the FRAD will not echo received characters back to the terminal. When Local Echo is set to Auto, the FRAD will echo characters back to the local terminal only if the remote echo option has not been successfully negotiated between the local and remote Telnet modules (the FRAD is performing the Store and Forward option).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), enable(2), disable(3)  

fsTelnetTermRemoteEcho 2.1.10.13.1.1.14
There are three settings for this option- Enabled: The FRAD will not attempt to negotiate the Telnet echo option and will refuse to implement it even if the remote Telnet module requests it to do so. The FRAD will always store data from the local terminal until a is received or the buffer is filled, then forwards it to the host. Disabled: The FRAD will attempt to negotiate the Telnet echo option and will implement it if requested by the remote Telnet module. The FRAD will forward all received data immediately to the host even if the remote Telnet module refused the negotiation. Auto: The FRAD will attempt to negotiate the Telnet echo option and will implement it if requested. If the negotiation fails, the FRAD will store and forward data. If the negotiation succeeds, the FRAD will forward all data received from the local terminal immediately.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), enable(2), disable(3)  

fsTelnetTermForceDTR 2.1.10.13.1.1.15
This option allows you to force DTR to be On. Forcing a DTR signal is useful if the terminal equipment connected to the FRAD port fails to supply DTR. This will also prevent a Telnet session from being disconnected if DTR is dropped.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

fsTelnetTermForceDCD 2.1.10.13.1.1.16
This option allows you to force DCD to be On. The Telnet module raises and lowers this control signal to indicate the connection status of its Telnet session. Forcing the signal On is useful if the varying DCD signal has a negative effect on the operation of the attached terminal.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

fsTelnetTermForceDSR 2.1.10.13.1.1.17
This option allows you to force DSR to be On. The Telnet module raises and lowers this control signal to indicate the connection status of its Telnet session. Forcing the signal On is useful if the varying DSR signal has a negative effect on the operation of the attached terminal.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

fsTelnetTermLocalTCP 2.1.10.13.1.1.18
This option allows you to enter the Local TCP Port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

fsTelnetTermRemoteTCP 2.1.10.13.1.1.19
This option allows you to enter the Remote TCP Port number. If you are using the DTR Dial or Continuous Connection Types, the number entered here will be used to establish a Telnet session. If you are using the Manual Connection Type, you do not need to enter this number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

fsTelnetTermRemoteIP 2.1.10.13.1.1.20
Enter the IP address of the remote device.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

fsTelnetTermXpadLogPort 2.1.10.13.1.1.21
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

fsTelnetTermStatus 2.1.10.13.1.1.22
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER view(1), modify(2)  

fsALCDefTable 2.1.10.16.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FsALCDefEntry

fsALCDefEntry 2.1.10.16.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FsALCDefEntry  

fsALCPortNo 2.1.10.16.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER portN(1), port1(2), port2(3), port3(4), port4(5), port10(10), port11(11), port12(12), port13(13), port14(14), port15(15), port16(16), port17(17), port18(18), port19(19), port20(20), port21(21), port22(22), port23(23), port24(24), port25(25), port26(26), port27(27), port28(28), port29(29)  

fsALCSpeed 2.1.10.16.1.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER baud001200(1), baud002400(2), baud004800(3), baud009600(4), baud019200(5), baud038400(6), baud048000(7), baud057600(8), baud115200(9)  

fsALCPollTime 2.1.10.16.1.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..5000  

fsALCTimeOut 2.1.10.16.1.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..5000  

fsALCControllerIA 2.1.10.16.1.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..8)  

fsALCControllerIPAddr 2.1.10.16.1.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

fsALCRemoteHostIPAddr 2.1.10.16.1.1.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

fsALCESDIPAddr 2.1.10.16.1.1.8
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

fsALCStatus 2.1.10.16.1.1.9
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER view(1), modify(2)  

fsSDLC2DefTable 2.1.10.20.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FsSDLC2DefEntry

fsSDLC2DefEntry 2.1.10.20.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FsSDLC2DefEntry  

fsSDLC2PortNo 2.1.10.20.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER portN(1), port1(2), port2(3), port3(4), port4(5), port10(10), port11(11), port12(12), port13(13), port14(14), port15(15), port16(16), port17(17), port18(18), port19(19), port20(20), port21(21), port22(22), port23(23), port24(24), port25(25), port26(26), port27(27), port28(28), port29(29)  

fsSDLC2Speed 2.1.10.20.1.1.2
The sync speed the FRAD will provide/accept clock to/from the user's equipment
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER external(1), baud002400(2), baud004800(3), baud009600(4), baud019200(5), baud038400(6), baud048000(7), baud056000(8), baud064000(9), baud096000(10), baud128000(11), baud192000(12), baud256000(13), baud384000(14), baud512000(15), baud768000(16), baud1024000(17)  

fsSDLC2PollType 2.1.10.20.1.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER term-end(1), host-end(2)  

fsSDLC2DataFmt 2.1.10.20.1.1.4
Data Format for the port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER nrz(1), nrzi(2)  

fsSDLC2IdleMark 2.1.10.20.1.1.5
Idle/Mark for the port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER mark(1), flag(2)  

fsSDLC2DCD 2.1.10.20.1.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER switched(1), forced(2)  

fsSDLC2UserBuffHigh 2.1.10.20.1.1.7
High-water mark for user buffers.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 16..31  

fsSDLC2UserBuffLow 2.1.10.20.1.1.8
High-water mark for user buffers.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..15  

fsSDLC2Status 2.1.10.20.1.1.9
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER view(1), modify(2)  

fsSDLC2StnTable 2.1.10.20.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FsSDLC2StnEntry

fsSDLC2StnEntry 2.1.10.20.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FsSDLC2StnEntry  

fsSDLC2StnPortNo 2.1.10.20.2.1.1
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER portN(1), port1(2), port2(3), port3(4), port4(5), port10(10), port11(11), port12(12), port13(13), port14(14), port15(15), port16(16), port17(17), port18(18), port19(19), port20(20), port21(21), port22(22), port23(23), port24(24), port25(25), port26(26), port27(27), port28(28), port29(29)  

fsSDLC2StnIndex 2.1.10.20.2.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fsSDLC2StnAddr 2.1.10.20.2.1.3
This value is the poll address of the secondary link station for this SDLC link. It uniquely identifies the SDLC link station within a single SDLC port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(2)  

fsSDLC2DuplexMode 2.1.10.20.2.1.4
This object controls the transmit-receive capabilities for this SDLC link station.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER twa(1), tws(2)  

fsSDLC2StnRWindow 2.1.10.20.2.1.5
This object controls the maximum number of unacknowledged I-frames which an SDLC link station may receive. This should range from 1 to 7.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..7  

fsSDLC2StnXWindow 2.1.10.20.2.1.6
This object controls the maximum number of consecutive unacknowledged I-frames which an SDLC link station shall send without an acknowledgement. This shall range from 1 to 7.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..7  

fsSDLC2InactTimer 2.1.10.20.2.1.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..60  

fsSDLC2AckTimer 2.1.10.20.2.1.8
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..60  

fsSDLC2MaxRetries 2.1.10.20.2.1.9
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..60  

fsSDLC2StnStatus 2.1.10.20.2.1.10
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER view(1), add(2), delete(3), modify(4)  

fsX25NEWL1DefTable 2.1.10.21.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FsX25NEWL1DefEntry

fsX25NEWL1DefEntry 2.1.10.21.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FsX25NEWL1DefEntry  

fsX25NEWL1PortNo 2.1.10.21.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER portN(1), port1(2), port2(3), port3(4), port4(5), port10(10), port11(11), port12(12), port13(13), port14(14), port15(15), port16(16), port17(17), port18(18), port19(19), port20(20), port21(21), port22(22), port23(23), port24(24), port25(25), port26(26), port27(27), port28(28), port29(29)  

fsX25NEWL1Speed 2.1.10.21.1.1.2
The sync speed the FRAD will provide/accept clock to/from the user's equipment
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER external(0), baud002400(1), baud004800(2), baud009600(3), baud019200(4), baud038400(5), baud048000(6), baud056000(7), baud064000(8), baud096000(9), baud128000(10), baud192000(11), baud256000(12), baud384000(13), baud512000(14), baud768000(15), baud1024000(16)  

fsX25NEWL1GptName 2.1.10.21.1.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(11)  

fsX25NEWL1Status 2.1.10.21.1.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER view(1), modify(2)  

fsX25NEWL2DefTable 2.1.10.21.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FsX25NEWL2DefEntry

fsX25NEWL2DefEntry 2.1.10.21.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FsX25NEWL2DefEntry  

fsX25NEWL2PortNo 2.1.10.21.2.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER portN(1), port1(2), port2(3), port3(4), port4(5), port10(10), port11(11), port12(12), port13(13), port14(14), port15(15), port16(16), port17(17), port18(18), port19(19), port20(20), port21(21), port22(22), port23(23), port24(24), port25(25), port26(26), port27(27), port28(28), port29(29)  

fsX25NEWL2Mode 2.1.10.21.2.1.2
The LAPB Mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dte(1), dce(2)  

fsX25NEWL2LinkActivator 2.1.10.21.2.1.3
This identifies which node, DTE or DCE, will activate the link.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dte(1), dce(2)  

fsX25NEWL2T1AckTimer 2.1.10.21.2.1.4
The T1 timer for this interface. It specifies the maximum time to wait for acknowledgment of a PDU. This timer is in seconds. The default value is 3.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..10  

fsX25NEWL2T2ResTimer 2.1.10.21.2.1.5
The default T2 timer for this interface. This specifies the maximum time to wait before sending an acknowledgment for a sequenced PDU. A value of zero means there will be no delay in acknowledgement generation. This value is entered in seconds. The default value is 1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..20  

fsX25NEWL2T3DisconnectTimer 2.1.10.21.2.1.6
The T3 timer for this interface. This specifies the time to wait before considering the link disconnected. A value of zero indicates the link will be considered disconnected upon completion of the frame exchange to disconnect the link. This value is expressed in seconds. The default value is 60.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..180  

fsX25NEWL2N2RetryCount 2.1.10.21.2.1.7
The default N2 retry counter for this interface. This specifies the number of times a PDU will be resent after the T1 timer expires without an acknowledgement for the PDU. The default value is 20. The valid values range from 0 to 65535.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..30  

fsX25NEWL2Sequence 2.1.10.21.2.1.8
LAPB Sequencing.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER module-8(1), module-128(2)  

fsX25NEWL2RxKWindowSize 2.1.10.21.2.1.9
The default receive window size for this Interface. This is the maximum number of unacknowledged sequenced PDUs that may be outstanding from this DTE at any one time. The default value is 7. The valid values range from 1 to 127.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..127  

fsX25NEWL2TxKWindowSize 2.1.10.21.2.1.10
The default transmit window size for this Interface. PDUs that may be outstanding from this DTE at any one time. The default value is 7. The valid values range from 1 to 127.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..127  

fsX25NEWL2Status 2.1.10.21.2.1.11
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER view(1), modify(2)  

fsX25NEWL3DefTable 2.1.10.21.3
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FsX25NEWL3DefEntry

fsX25NEWL3DefEntry 2.1.10.21.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FsX25NEWL3DefEntry  

fsX25NEWL3PortNo 2.1.10.21.3.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER portN(1), port1(2), port2(3), port3(4), port4(5), port10(10), port11(11), port12(12), port13(13), port14(14), port15(15), port16(16), port17(17), port18(18), port19(19), port20(20), port21(21), port22(22), port23(23), port24(24), port25(25), port26(26), port27(27), port28(28), port29(29)  

fsX25NEWL3Mode 2.1.10.21.3.1.2
Identifies DCE/DTE mode in which the interface operates.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dte(1), dce(2)  

fsX25NEWL3TxPacketSize 2.1.10.21.3.1.3
The transmit packet size in octets for a circuit. If this parameter is changed and if there are any active VCs, the port will be reinitialized (PVCs will be reset and SVCs will be cleared). The default value is 128.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 128..4096  

fsX25NEWL3RxPacketSize 2.1.10.21.3.1.4
The receive packet size in octets for a circuit. If this parameter is changed and if there are any active VCs, the port will be reinitialized (PVCs will be reset and SVCs will be cleared). The default value is 128.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 128..4096  

fsX25NEWL3Sequencing 2.1.10.21.3.1.5
The modulus of the packet sequence number space. The default value is 'modulo8'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER module-8(1), module-128(2)  

fsX25NEWL3TxWindowSize 2.1.10.21.3.1.6
The receive packet size in octets for a circuit. If this parameter is changed and if there are any active VCs, the port will be reinitialized (PVCs will be reset and SVCs will be cleared). The default value is 7. The valid values range from 1 to 127.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..127  

fsX25NEWL3RxWindowSize 2.1.10.21.3.1.7
The receive window size for a circuit. If this parameter is changed and if there are any active VCs, the particular port will be reinitialized (PVCs will be reset and SVCs will be cleared). The default value is 7. The valid values range from 1 to 127.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..127  

fsX25NEWL3RestartTimer 2.1.10.21.3.1.8
The T20 restart timer in seconds. The default value is 180. The valid values range from 10 to 600.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..600  

fsX25NEWL3CallTimer 2.1.10.21.3.1.9
The T21 Call timer in seconds. The default value is 200. The valid values range from 10 to 600.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..600  

fsX25NEWL3ResetTimer 2.1.10.21.3.1.10
The T22 Reset timer in seconds. The default value is 180. The valid values range from 10 to 600.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..600  

fsX25NEWL3ClearTimer 2.1.10.21.3.1.11
The T23 Clear timer in seconds. The default value is 180. The valid values range from 10 to 600.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..600  

fsX25NEWL3InputCallFacOpt 2.1.10.21.3.1.12
This field controls the manner in which this port will respond when presented with any input Call Packet containing faciliities that are not actively supported by the system. Regardless of the value of this object, the system will always clear calls containing Flow Control Parameter Negotiation facilities and will handle Reverse Charging facilities as configured by the operator. The value of this object will have no effect on system-generated call processing; any facility present in calls received by multiprotocol switching applications will always be ignored. If this object is set to 'pass-facilities-through', which is the default, unsupported facilities will be passed unchanged through the system. If this object is set to 'remove-facilities', unsupported facilities will be stripped from the packet before it is passed on through the system. If this object is set to 'clear-call', calls using unsupported facilities will be cleared by the system with the Invalid Facility Clear Cause and Diagnostic Code combination.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER pass-facilities-through(1), remove-facilities(2), clear-call(3)  

fsX25NEWL3OutputCallFacOpt 2.1.10.21.3.1.13
This field controls the manner in which this port will respond when presented with any output Call Packet containing faciliities that are not actively supported by the system. Regardless of the value of this object, the system will always clear calls containing Flow Control Parameter Negotiation facilities and will handle Reverse Charging facilities as configured by the operator. The value of this object will have no effect on system-generated call processing; any facility present in calls received by multiprotocol switching applications will always be ignored. If this object is set to 'pass-facilities-through', which is the default, unsupported facilities will be passed unchanged through the system. If this object is set to 'remove-facilities', unsupported facilities will be stripped from the packet before it is passed on through the system. If this object is set to 'clear-call', calls using unsupported facilities will be cleared by the system with the Invalid Facility Clear Cause and Diagnostic Code combination.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER pass-facilities-through(1), remove-facilities(2), clear-call(3)  

fsX25NEWL3HPVC 2.1.10.21.3.1.14
Lowest Incoming channel. The default value is 0. The valid values range from 0 to 4095.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

fsX25NEWL3LSVC 2.1.10.21.3.1.15
Highest Incoming channel. A value of zero indicates no channels in this range. The default value is 0. The valid values range from 0 to 4095.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

fsX25NEWL3HSVC 2.1.10.21.3.1.16
Lowest Two-way channel. The default value is 1. The valid values range from 1 to 4095.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..4095  

fsX25NEWL3MaxActiveVC 2.1.10.21.3.1.17
Maximum Active VCs at a time. The default value is 20. The valid values range from 0 to 100.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

fsX25NEWL3Status 2.1.10.21.3.1.18
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER view(1), modify(2)  

fsXPADDefTable 2.1.10.22.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FsXPADDefEntry

fsXPADDefEntry 2.1.10.22.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FsXPADDefEntry  

fsXPADPortNo 2.1.10.22.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER portN(1), port1(2), port2(3), port3(4), port4(5), port10(10), port11(11), port12(12), port13(13), port14(14), port15(15), port16(16), port17(17), port18(18), port19(19), port20(20), port21(21), port22(22), port23(23), port24(24), port25(25), port26(26), port27(27), port28(28), port29(29)  

fsXPADX3Speed 2.1.10.22.1.1.2
This object specifies the baudrate at which the PAD operates the link between the PAD and the TTY. Note that this object may only be read.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER baud001200(1), baud002400(2), baud004800(3), baud009600(4), baud019200(5), baud038400(6), baud048000(7), baud057600(8), baud115200(9)  

fsXPADDataBits 2.1.10.22.1.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER seven-bits(7), eight-bits(8)  

fsXPADStopBits 2.1.10.22.1.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER one-bit(1), two-bits(2)  

fsXPADFlowControl 2.1.10.22.1.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), tX-Only(2), rX-Only(3), on(4)  

fsXPADFlowConType 2.1.10.22.1.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER rTS-CTS(1), xON-XOFF(2)  

fsXPADSubAddr 2.1.10.22.1.1.7
Sub Address .
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(15)  

fsXPADAllowMnemonics 2.1.10.22.1.1.8
This boolean object specifies whether or not the use of Mnemonics is permissible at the PAD port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER not-allowed(1), allowed(2)  

fsXPADIdleVCTmr 2.1.10.22.1.1.9
This object specifies the maximum duration in minutes for which an SVC on the PAD port may be allowed to remain idle. A value of zero indicates the VC may be allowed to remain idle forever. This timer is in seconds. The default value is 180.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..600  

fsXPADX3ProfileSelect 2.1.10.22.1.1.10
This is an index into the padX3ProfileTable the entries within which are to be the default X.3 paramaters for the PAD port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER simple(1), transparent(2), user-Configured(3)  

fsXPADTelLogPort 2.1.10.22.1.1.11
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER n-a(0), portN(1), port1(2), port2(3), port3(4), port4(5), port10(10), port11(11), port12(12), port13(13), port14(14), port15(15), port16(16), port17(17), port18(18), port19(19), port20(20), port21(21), port22(22), port23(23), port24(24), port25(25), port26(26), port27(27), port28(28), port29(29)  

fsXPADStatus 2.1.10.22.1.1.12
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER view(1), modify(2)  

fsXPADProfile1DefTable 2.1.10.22.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FsXPADProfile1Entry

fsXPADProfile1Entry 2.1.10.22.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FsXPADProfile1Entry  

fsXPADPro1PortNo 2.1.10.22.2.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER portN(1), port1(2), port2(3), port3(4), port4(5), port10(10), port11(11), port12(12), port13(13), port14(14), port15(15), port16(16), port17(17), port18(18), port19(19), port20(20), port21(21), port22(22), port23(23), port24(24), port25(25), port26(26), port27(27), port28(28), port29(29)  

fsXPADX3RecallChar 2.1.10.22.2.1.2
This object specifies the value of the PAD Recall character which allows the TTY to initiate an escape from the 'data transfer' state or the 'connection in progress' state to send 'PAD Command signals'. This object may take one of the following values: - 0 Not possible - 1 Character DLE - 32 to 126 The graphic character corresponding to the value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..126  

fsXPADX3EchoEnable 2.1.10.22.2.1.3
This object specifies whether the character received from the TTY is transmitted back (apart from being interpreted by the PAD).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

fsXPADX3DataFwdChar 2.1.10.22.2.1.4
This object defines the sets of character(s) received from the TTY that are to recognised by the PAD as an indication to complete the assembly and forward a 'complete packet sequence' as defined in <>.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(0), all-AlphaNumeric-Chars(1), cr(2), all-Unprintable-Chars(126), all-Chars(127)  

fsXPADX3IdleTmr 2.1.10.22.2.1.5
This object defines the duration of an interval between successive characters received from the TTY, which, when exceeded, will cause the PAD to terminate the assembly of a packet and forward the same. This timer is in 20th of a second. The default value is 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

fsXPADX3ANCDevCtrl 2.1.10.22.2.1.6
This object allows for flow control between the PAD and the TTY. If this is set to 'dxfer', flow control is enabled only in the 'data transfer' state. The other permissible values are self-explanatory.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), dxfer(2), always(3)  

fsXPADX3PSSCtrl 2.1.10.22.2.1.7
This object specifies whether or not and in what format PAD Service signals are transmitted.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(0), ss-Other-than-PADPrompt(1), all-SS(5)  

fsXPADX3ActOnBreak 2.1.10.22.2.1.8
This object determines the action to be initiated by the PAD upon receipt of a break signal from the TTY.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), rst(2), esc(3)  

fsXPADX3DiscardOutput 2.1.10.22.2.1.9
This object provides for the PAD to discard the content of user sequences in packets upon request rather than disassembling and transmitting these to the TTY.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

fsXPADX3CRPadding 2.1.10.22.2.1.10
This object provides for the automatic insertion by the PAD of padding characters in the character stream transmitted to the TTY after the occurence of a 'carriage return`.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

fsXPADX3LineFolding 2.1.10.22.2.1.11
This object provides for the automatic insertion by the PAD of appropriate format effectors in the character stream transmitted to the TTY. In other words, this object specifies the maxmimum number of graphic characters that may be present in a line.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

fsXPADPro1Status 2.1.10.22.2.1.12
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER view(1), modify(2)  

fsXPADProfile2DefTable 2.1.10.22.3
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FsXPADProfile2Entry

fsXPADProfile2Entry 2.1.10.22.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FsXPADProfile2Entry  

fsXPADPro2PortNo 2.1.10.22.3.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER portN(1), port1(2), port2(3), port3(4), port4(5), port10(10), port11(11), port12(12), port13(13), port14(14), port15(15), port16(16), port17(17), port18(18), port19(19), port20(20), port21(21), port22(22), port23(23), port24(24), port25(25), port26(26), port27(27), port28(28), port29(29)  

fsXPADX3FlowCtrl 2.1.10.22.3.1.2
This object determines whether or not flow control is enabled between the TTY and the PAD.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

fsXPADX3LFAfterCR 2.1.10.22.3.1.3
This object provides for the automatic insertion by the PAD of a linefeed (LF) character in the character stream to or from the TTY after the occurence of each carriage return (CR) character. This is applicable only in the 'data transfer' state.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..7  

fsXPADX3LFPadding 2.1.10.22.3.1.4
This object provides for the automatic insertion by the PAD of padding character(s) in the character stream transmitted to the TTY after the occurence of an LF character. This is applicable only in the 'data transfer' state.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

fsXPADX3Editing 2.1.10.22.3.1.5
This object specifies whether or not the character delete, line delete and the line display editing capabilities are enabled in the 'data transfer' state.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

fsXPADX3CharDelChar 2.1.10.22.3.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..127  

fsXPADX3LineDelChar 2.1.10.22.3.1.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..127  

fsXPADX3LineDisplayChar 2.1.10.22.3.1.8
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..127  

fsXPADX3EditingPSS 2.1.10.22.3.1.9
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..126  

fsXPADX3EchoMask 2.1.10.22.3.1.10
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no-Echo-Mask(0), no-Echo-of-CR(1), no-Echo-of-LF(2), no-Echo-of-VT-HT-FF(4), no-Echo-of-BEL-BS(8), no-Echo-of-ESC-ENQ(16), no-Echo-of-ACK-NAK-STX-SOH-EOT-ETB-ETX(32), no-Echo-of-CharDel-LineDel-LineDispChar(64), no-Echo-of-NonGraphicChars(128)  

fsXPADX3Parity 2.1.10.22.3.1.11
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noParityChecking-or-Generation(0), parityChecking-and-Generation(3)  

fsXPADX3PageWait 2.1.10.22.3.1.12
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

fsXPADPro2Status 2.1.10.22.3.1.13
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER view(1), modify(2)  

fsPPPNewDefTable 2.1.10.23.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FsPPPNewDefEntry

fsPPPNewDefEntry 2.1.10.23.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FsPPPNewDefEntry  

fsPPPNewPortNo 2.1.10.23.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER portN(1), port1(2), port2(3), port3(4), port4(5), port10(10), port11(11), port12(12), port13(13), port14(14), port15(15), port16(16), port17(17), port18(18), port19(19), port20(20), port21(21), port22(22), port23(23), port24(24), port25(25), port26(26), port27(27), port28(28), port29(29)  

fsPPPNewType 2.1.10.23.1.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER sYNC(40), aSYNC(41)  

fsPPPNewSpeed 2.1.10.23.1.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER baud001200(1), baud002400(2), baud004800(3), baud009600(4), baud019200(5), baud038400(6), baud048000(7), baud056000(8), baud064000(9), baud096000(10), baud128000(11), baud192000(12), baud256000(13), baud384000(14), baud512000(15), baud768000(16), baud1024000(17), baud057600(18), baud115200(19)  

fsPPPNewLQM 2.1.10.23.1.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2)  

fsPPPNewLQMPert 2.1.10.23.1.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

fsPPPNewLQMTimer 2.1.10.23.1.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..300  

fsPPPNewIPXNetNumber 2.1.10.23.1.1.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..8)  

fsPPPNewNodeNumber 2.1.10.23.1.1.8
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..12)  

fsPPPNewSapMode 2.1.10.23.1.1.9
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(0), send(1), listen(2), off(3)  

fsPPPNewLCPMRU 2.1.10.23.1.1.10
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

fsPPPNewAddrNegoSel 2.1.10.23.1.1.11
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dynamically(1), negotiate(2), do-Not-Negotiate(3)  

fsPPPNewAddrNego 2.1.10.23.1.1.12
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

fsPPPNewLocalUserName 2.1.10.23.1.1.13
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

fsPPPNewLocalPasswd 2.1.10.23.1.1.14
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

fsPPPNewAuthProtocol 2.1.10.23.1.1.15
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER cHAP(1), pAP(2), cHAP-PAP(3), pAP-CHAP(4), nONE(5)  

fsPPPNewStatus 2.1.10.23.1.1.16
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER view(1), modify(2)  

fsPPPNewRemoteUserTable 2.1.10.23.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FsPPPNewRemoteUserEntry

fsPPPNewRemoteUserEntry 2.1.10.23.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FsPPPNewRemoteUserEntry  

fsPPPRemotePortNo 2.1.10.23.2.1.1
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER portN(1), port1(2), port2(3), port3(4), port4(5), port10(10), port11(11), port12(12), port13(13), port14(14), port15(15), port16(16), port17(17), port18(18), port19(19), port20(20), port21(21), port22(22), port23(23), port24(24), port25(25), port26(26), port27(27), port28(28), port29(29)  

fsPPPRemoteIndex 2.1.10.23.2.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

fsPPPRemoteName 2.1.10.23.2.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

fsPPPRemotePasswd 2.1.10.23.2.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

fsPPPRemoteStatus 2.1.10.23.2.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER view(1), add(2), delete(3), modify(4)  

fsPPPMLinkDefTable 2.1.10.24.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FsPPPMLinkDefEntry

fsPPPMLinkDefEntry 2.1.10.24.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FsPPPMLinkDefEntry  

fsPPPMLinkPortNo 2.1.10.24.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER portN(1), port1(2), port2(3), port3(4), port4(5), port10(10), port11(11), port12(12), port13(13), port14(14), port15(15), port16(16), port17(17), port18(18), port19(19), port20(20), port21(21), port22(22), port23(23), port24(24), port25(25), port26(26), port27(27), port28(28), port29(29)  

fsPPPMLinkIPXNetNumber 2.1.10.24.1.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..8)  

fsPPPMLinkNodeNumber 2.1.10.24.1.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..12)  

fsPPPMLinkSapMode 2.1.10.24.1.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(0), send(1), listen(2), off(3)  

fsPPPMLinkMRRU 2.1.10.24.1.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

fsPPPMLinkMPHeader 2.1.10.24.1.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER must(1), not-must(2)  

fsPPPMLinkAddrNegoSel 2.1.10.24.1.1.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dynamically(1), negotiate(2), do-Not-Negotiate(3)  

fsPPPMLinkAddrNego 2.1.10.24.1.1.8
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

fsPPPMLinkLocalUserName 2.1.10.24.1.1.9
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

fsPPPMLinkLocalPasswd 2.1.10.24.1.1.10
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

fsPPPMLinkAuthProtocol 2.1.10.24.1.1.11
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER cHAP(1), pAP(2), cHAP-PAP(3), pAP-CHAP(4), nONE(5)  

fsPPPMLinkStatus 2.1.10.24.1.1.12
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER view(1), modify(2)  

fsPPPMLinkMemberTable 2.1.10.24.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FsPPPMLinkMemberEntry

fsPPPMLinkMemberEntry 2.1.10.24.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FsPPPMLinkMemberEntry  

fsPPPMemberPortNo 2.1.10.24.2.1.1
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER portN(1), port1(2), port2(3), port3(4), port4(5), port10(10), port11(11), port12(12), port13(13), port14(14), port15(15), port16(16), port17(17), port18(18), port19(19), port20(20), port21(21), port22(22), port23(23), port24(24), port25(25), port26(26), port27(27), port28(28), port29(29)  

fsPPPMemberIndex 2.1.10.24.2.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

fsPPPMemberPort 2.1.10.24.2.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER portN(1), port1(2), port2(3), port3(4), port4(5), port10(10), port11(11), port12(12), port13(13), port14(14), port15(15), port16(16), port17(17), port18(18), port19(19), port20(20), port21(21), port22(22), port23(23), port24(24), port25(25), port26(26), port27(27), port28(28), port29(29)  

fsPPPMemberStatus 2.1.10.24.2.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER view(1), add(2), delete(3), modify(4)  

fsPPPMLinkRemoteUserTable 2.1.10.24.3
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FsPPPMLinkRemoteUserEntry

fsPPPMLinkRemoteUserEntry 2.1.10.24.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FsPPPMLinkRemoteUserEntry  

fsPPPMLRemotePortNo 2.1.10.24.3.1.1
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER portN(1), port1(2), port2(3), port3(4), port4(5), port10(10), port11(11), port12(12), port13(13), port14(14), port15(15), port16(16), port17(17), port18(18), port19(19), port20(20), port21(21), port22(22), port23(23), port24(24), port25(25), port26(26), port27(27), port28(28), port29(29)  

fsPPPMLRemoteIndex 2.1.10.24.3.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

fsPPPMLRemoteName 2.1.10.24.3.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

fsPPPMLRemotePasswd 2.1.10.24.3.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

fsPPPMLRemoteStatus 2.1.10.24.3.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER view(1), add(2), delete(3), modify(4)  

fsPortEtherDefinition 2.1.10.25.1
OBJECT IDENTIFIER    

fsPortEtherIPXEncaps 2.1.10.25.1.1
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER iEEE802-3(1), iEEE802-2(2), iEEE802-2SNAP(3), ether(4)  

fsPortEtherNetNumber 2.1.10.25.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..8)  

fsPortEtherSmartARP 2.1.10.25.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

fsPortEtherSapMode 2.1.10.25.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(0), send(1), listen(2), off(3)  

fsPortTokenDefinition 2.1.10.26.1
OBJECT IDENTIFIER    

fsPortTokenSpeed 2.1.10.26.1.1
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER mpbs-4(1), mpbs-16(2), unknown(3)  

fsPortTokenEarlyRelease 2.1.10.26.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

fsPortTokenIPXNetNum 2.1.10.26.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..8)  

fsPortTokenIPXEncapsu 2.1.10.26.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER iEEE802-2Encap(1), iEEE802-2-SNAPEncap(2), invalid(3)  

fsPortTokenSmartARP 2.1.10.26.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

fsPortTokenSapMode 2.1.10.26.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(0), send(1), listen(2), off(3)  

fsInterDefTable 2.1.11.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FsInterDefEntry

fsInterDefEntry 2.1.11.1.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FsInterDefEntry  

fsInterfacePortNo 2.1.11.1.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER sup-Voice(1), portN(2), port1(3), port2(4), port3(5), port4(6)  

fsInterfaceType 2.1.11.1.1.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER sUP(1), e1(2), t1(3), vOICE(4), sERIAL(5), cSU-DSU(6), dT1E1(7), uNDEFINED(200)  

fsInterfaceDesc 2.1.11.1.1.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

fsPortE1DefTable 2.1.11.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FsPortE1DefEntry

fsPortE1DefEntry 2.1.11.2.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FsPortE1DefEntry  

fsPortE1PortNo 2.1.11.2.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER vOICE(1), portN(2), port1(3), port2(4), port3(5), port4(6)  

fsPortE1DsuFrameFormat 2.1.11.2.1.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER framed(1), unframed(2), na(222)  

fsPortE1DsuCRC 2.1.11.2.1.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2), na(222)  

fsPortE1LineBuildout 2.1.11.2.1.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ft0-110(1), ft110-220(2), ft220-330(3), ft330-440(4), ft440-550(5), ft550-660(6), g703-75(7), g703-120(8), na(222)  

fsPortE1DsuClock 2.1.11.2.1.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER line(1), internal(2), na(222)  

fsPortE1DsuTimeSlots 2.1.11.2.1.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(24)  

fsPortE1DsuDataType 2.1.11.2.1.1.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), invert(2), na(222)  

fsPortE1DsuDisFrame 2.1.11.2.1.1.8
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2), na(222)  

fsPortE1DsuAISTrans 2.1.11.2.1.1.9
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2), na(222)  

fsPortE1DsuLineLoop 2.1.11.2.1.1.10
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER activateLoopBack(1), removeLoopBack(2), na(222)  

fsPortE1ChannelMode 2.1.11.2.1.1.11
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER channelized(1), unchannelized(2), na(222)  

fsPortE1Channel64KRate 2.1.11.2.1.1.12
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(24)  

fsPortE1Channel56KRate 2.1.11.2.1.1.13
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(24)  

fsPortE1Channel48KRate 2.1.11.2.1.1.14
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(24)  

fsPortE1ConfigStatus 2.1.11.2.1.1.15
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER view(1), modify(2)  

fsPortT1DefTable 2.1.11.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FsPortT1DefEntry

fsPortT1DefEntry 2.1.11.3.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FsPortT1DefEntry  

fsPortT1PortNo 2.1.11.3.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER vOICE(1), portN(2), port1(3), port2(4), port3(5), port4(6)  

fsPortT1DsuFrameFormat 2.1.11.3.1.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER d4(1), eSF(2), unframed(3), na(222)  

fsPortT1DsuLineCode 2.1.11.3.1.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER aMI(1), b8ZS(2), na(222)  

fsPortT1DsuBitStuffing 2.1.11.3.1.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2), na(222)  

fsPortT1DsuLineBuildOut 2.1.11.3.1.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER db-0(1), db-Seven-and-half(2), db-15(3), db-TwentyTwo-and-half(4), ft-133(5), ft-266(6), ft-399(7), ft-533(8), ft-655(9), na(222)  

fsPortT1DsuGSTACKLineBuildOut 2.1.11.3.1.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ft0-110(1), ft110-220(2), ft220-330(3), ft330-440(4), ft440-550(5), ft550-660(6), ft-greater-600(7), square(8), na(222)  

fsPortT1DsuClock 2.1.11.3.1.1.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER line(1), internal(2), na(222)  

fsPortT1DsuLineLoopBack 2.1.11.3.1.1.8
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2), na(222)  

fsPortT1DsuLocAnalog 2.1.11.3.1.1.9
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER up(1), down(2), na(222)  

fsPortT1DsuLocDigital 2.1.11.3.1.1.10
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER up(1), down(2), na(222)  

fsPortT1DsuRemAnalog 2.1.11.3.1.1.11
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER up(1), down(2), na(222)  

fsPortT1DsuRemDigital 2.1.11.3.1.1.12
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER up(1), down(2), na(222)  

fsPortT1DsuTimeSlotDataRate 2.1.11.3.1.1.13
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER k48(1), k56(2), k64(3), na(222)  

fsPortT1DsuTimeSlots 2.1.11.3.1.1.14
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(24)  

fsPortT1DsuTimeSlotDataType 2.1.11.3.1.1.15
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), invert(2), na(222)  

fsPortT1DsuYellowAlarm 2.1.11.3.1.1.16
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2), na(222)  

fsPortT1ChannelMode 2.1.11.3.1.1.17
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER channelized(1), unchannelized(2), na(222)  

fsPortT1Channel64KRate 2.1.11.3.1.1.18
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(24)  

fsPortT1Channel56KRate 2.1.11.3.1.1.19
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(24)  

fsPortT1Channel48KRate 2.1.11.3.1.1.20
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(24)  

fsPortT1ConfigStatus 2.1.11.3.1.1.21
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER view(1), modify(2)  

fsPortVoiceE1LineBuildOut 2.1.11.4.1
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ft0-110(1), ft110-220(2), ft220-330(3), ft330-440(4), ft440-550(5), ft550-660(6), g703-75(7), g703-120(8), na(222)  

fsPortVoiceE1Clock 2.1.11.4.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER line(1), internal(2), na(222)  

fsPortVoiceE1SeizeABCD 2.1.11.4.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

fsPortVoiceE1IdleABCD 2.1.11.4.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

fsPortVoiceT1FrameFormat 2.1.11.4.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER d4(1), eSF(2), unframed(3), na(222)  

fsPortVoiceT1LineCode 2.1.11.4.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER aMI(1), b8ZS(2), na(222)  

fsPortVoiceT1LineBuildOut 2.1.11.4.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ft0-110(1), ft110-220(2), ft220-330(3), ft330-440(4), ft440-550(5), ft550-660(6), ft-greater-600(7), square(8), na(222)  

fsPortVoiceT1Clock 2.1.11.4.8
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER line(1), internal(2), na(222)  

fsPortVoiceT1SeizeABCD 2.1.11.4.9
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

fsPortVoiceT1IdleABCD 2.1.11.4.10
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

fsPortVoiceTeleSignal 2.1.11.4.11
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER switch-CAS(1), switch-CCS(2), trans-CAS(3), trans-CCS(4), na(222)  

fsPortVoiceEMType 2.1.11.4.12
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER type-1(1), type-2(2), type-5(3), na(222)  

fsPortVoiceEMWire 2.1.11.4.13
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER invalid(1), two-wire(2), four-wire(3), na(222)  

fsPortSerialDefTable 2.1.11.5.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FsPortSerialDefEntry

fsPortSerialDefEntry 2.1.11.5.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FsPortSerialDefEntry  

fsPortSerialPortNo 2.1.11.5.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER vOICE(1), portN(2), port1(3), port2(4), port3(5), port4(6)  

fsPortSerialDteDceMode 2.1.11.5.1.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dTE(1), dCE(2), na(222)  

fsPortSerialConfigStatus 2.1.11.5.1.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER view(1), modify(2)  

fsPortSDSLTerminalType 2.1.11.6.1
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER central(1), remote(2), undefined(3), na(222)  

fsPortSDSLDataRate 2.1.11.6.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER r144kbps(1), r192kbps(2), r256kbps(3), r384kbps(4), r512kbps(5), r768kbps(6), r784kbps(7), r1168kbps(8), r1536kbps(9), r2048kbps(10), r2320kbps(11), undefined(12), na(222)  

fsPortSDSLAnalogAGC 2.1.11.6.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no-AGC(1), level-2(2), level-4(3), level-6(4), undefined(5), na(222)  

fsPortSDSLSeqSource 2.1.11.6.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER external(1), internal(2), undefined(3), na(222)  

fsPortSDSLTranScrambler 2.1.11.6.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2), undefined(3), na(222)  

fsPortSDSLRecDeScrambler 2.1.11.6.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2), undefined(3), na(222)  

fsPortSDSLEchoCanceller 2.1.11.6.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2), undefined(3), na(222)  

fsPortSDSLRemoteBitpump 2.1.11.6.8
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER conexent(1), non-Conexent(2), undefined(3), na(222)  

fsPortSDSLTestModes 2.1.11.6.9
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER external-Analog-Loopback(1), digital-Near-End-Loopback(2), digital-Far-End-Loopback(3), tx-Isolated-plus-3-Level-Pulse(4), tx-Isolated-plus-1-Level-Pulse(5), tx-Isolated-1-Level-Pulse(6), tx-Isolated-3-Level-Pulse(7), tx-4-Level-Scrambled-Data(8), tx-2-Level-Scrambled-Data(9), set-Nominal-VCXO-Frequency(10), set-Minimum-VCXO-Frequency(11), set-Maximum-VCXO-Frequency(12), internal-Analog-Loopback(13), isolated-Analog-Loopback(14), echo-Return-Loss-Enhancement(15), analog-AGC-Test(16), tx-Alternating-plus-3-3-Symbols(17), tx-Alternating-plus-1-1-Symbols(18), exit-Test-Mode(19), disabled(20), undefined(22), na(222)  

fsPortDT1E1ConfigTable 2.1.11.7.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FsPortDT1E1ConfigEntry

fsPortDT1E1ConfigEntry 2.1.11.7.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FsPortDT1E1ConfigEntry  

fsPortDT1E1ConfigPortNo 2.1.11.7.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER vOICE(1), portN(2), port1(3), port2(4), port3(5), port4(6)  

fsPortDT1E1ConfigPort1LineBuildout 2.1.11.7.1.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER lH-0dot0-Db(1), lH-7dot5-Db(2), lH-15dot0-Db(3), lH-22dot5-Db(4), lH-0-110ft(5), lH-110-220ft(6), lH-220-330ft(7), lH-330-440ft(8), lH-440-550ft(9), lH-550-660ft(10), g703-120(11), g703-75(12), na(222)  

fsPortDT1E1ConfigPort2LineBuildout 2.1.11.7.1.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER lH-0dot0-Db(1), lH-7dot5-Db(2), lH-15dot0-Db(3), lH-22dot5-Db(4), lH-0-110ft(5), lH-110-220ft(6), lH-220-330ft(7), lH-330-440ft(8), lH-440-550ft(9), lH-550-660ft(10), g703-120(11), g703-75(12), na(222)  

fsPortDT1E1ConfigPort1Clock 2.1.11.7.1.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER line(1), internal(2), na(222)  

fsPortDT1E1ConfigPort2Clock 2.1.11.7.1.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER line(1), internal(2), na(222)  

fsPortDT1E1ConfigPort1TimeSlot 2.1.11.7.1.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(24)  

fsPortDT1E1ConfigPort2TimeSlot 2.1.11.7.1.1.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(24)  

fsPortDT1E1ConfigPortType 2.1.11.7.1.1.8
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER e1(1), t1(2), na(222)  

fsPortDT1E1ConfigChannelMode 2.1.11.7.1.1.9
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER channelized(1), unchannelized(2), na(222)  

fsPortDT1E1ConfigChannel64KRate 2.1.11.7.1.1.10
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(24)  

fsPortDT1E1ConfigChannel56KRate 2.1.11.7.1.1.11
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(24)  

fsPortDT1E1ConfigChannel48KRate 2.1.11.7.1.1.12
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(24)  

fsPortDT1E1ConfigTimingRef 2.1.11.7.1.1.13
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER port1(1), port2(2), smm(3), na(222)  

fsPortDT1E1ConfigTDMClockRate 2.1.11.7.1.1.14
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER mHZ4(1), mHZ2(2), na(222)  

fsPortDT1E1ConfigStatus 2.1.11.7.1.1.15
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER view(1), modify(2)  

fsPortDT1E1ConfigPort1IdleABCDBits 2.1.11.7.1.1.16
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

fsPortDT1E1ConfigPort2IdleABCDBits 2.1.11.7.1.1.17
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

fsPortDT1E1ConfigPort1SeizeABCDBits 2.1.11.7.1.1.18
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

fsPortDT1E1ConfigPort2SeizeABCDBits 2.1.11.7.1.1.19
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

fsPortDT1E1CrossConnTable 2.1.11.7.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FsPortDT1E1CrossConnEntry

fsPortDT1E1CrossConnEntry 2.1.11.7.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FsPortDT1E1CrossConnEntry  

fsPortDT1E1CrossConnPortNo 2.1.11.7.2.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER vOICE(1), portN(2), port1(3), port2(4), port3(5), port4(6)  

fsPortDT1E1CrossConnSys-Port1 2.1.11.7.2.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(24)  

fsPortDT1E1CrossConnSys-Port2 2.1.11.7.2.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(24)  

fsPortDT1E1CrossConnPort1-Sys 2.1.11.7.2.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(24)  

fsPortDT1E1CrossConnPort1-Port2 2.1.11.7.2.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(24)  

fsPortDT1E1CrossConnPort2-Sys 2.1.11.7.2.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(24)  

fsPortDT1E1CrossConnPort2-Port1 2.1.11.7.2.1.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(24)  

fsPortDT1E1CrossConnStatus 2.1.11.7.2.1.8
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER view(1), modify(2)