FECLIENT827x-MIB

File: FECLIENT827x-MIB.mib (17739 bytes)

Imported modules

SNMPv2-SMI RFC-1212 RFC-1215
PROTEON-MIB RFC1213-MIB RFC1155-SMI

Imported symbols

Counter32 Integer32 IpAddress
OBJECT-TYPE TRAP-TYPE proElsSubSysEventMsg
ifIndex enterprises

Defined Types

Fe827xPCIAdapEntry  
SEQUENCE    
  fe827xPCIAdapSlotNum Integer32
  fe827xPCIAdapType INTEGER
  fe827xPCIAdapConfigType INTEGER
  fe827xPCIAdapATMMediaType INTEGER
  fe827xPCIAdapOperStatus INTEGER
  fe827xPCIAdapDiagStatus INTEGER
  fe827xPCIAdapNetworkStatus INTEGER
  fe827xPCIAdapFaultStatus INTEGER

Fe827xStatEntry  
SEQUENCE    
  fe827xStatQueueNum Integer32
  fe827xStatFramesSent Counter32
  fe827xStatFramesReceived Counter32

Fe827xDomainIfEntry  
SEQUENCE    
  fe827xSwitchDomainNum Integer32

Defined Values

ibmMSSClientMIB 1.3.6.1.4.1.2.6.118.4
OBJECT IDENTIFIER    

ibm 1.3.6.1.4.1.2
OBJECT IDENTIFIER    

ibmProd 1.3.6.1.4.1.2.6
OBJECT IDENTIFIER    

nwaysMSS 1.3.6.1.4.1.2.6.118
OBJECT IDENTIFIER    

fe827xNotificationGroup 1.3.6.1.4.1.2.6.118.4.0
OBJECT IDENTIFIER    

fe827xMIBObjectGroup 1.3.6.1.4.1.2.6.118.4.1
OBJECT IDENTIFIER    

fe827xMIBConformanceGroup 1.3.6.1.4.1.2.6.118.4.2
OBJECT IDENTIFIER    

fe827xProdGroup 1.3.6.1.4.1.2.6.118.4.1.1
OBJECT IDENTIFIER    

fe827xPCIAdapterGroup 1.3.6.1.4.1.2.6.118.4.1.2
OBJECT IDENTIFIER    

fe827xStatGroup 1.3.6.1.4.1.2.6.118.4.1.3
OBJECT IDENTIFIER    

fe827xSwitchGroup 1.3.6.1.4.1.2.6.118.4.1.4
OBJECT IDENTIFIER    

feMIBGroups 1.3.6.1.4.1.2.6.118.4.2.1
OBJECT IDENTIFIER    

feMIBCompliances 1.3.6.1.4.1.2.6.118.4.2.2
OBJECT IDENTIFIER    

fe827xResetFlag 1.3.6.1.4.1.2.6.118.4.1.1.1
The flag that controls the reset process in this blade. This variable shall assume a value of noreset(1) in the absence of a request for a reset from the management application. This variable shall assume a value of reboot(2) if the management application requests that this blade execute a complete hardware reboot which reloads the code load from storage.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noreset(1), reboot(2)  

fe827xDRAMInstalled 1.3.6.1.4.1.2.6.118.4.1.1.2
The total amount of dynamic RAM installed on this blade. The amount is in units of megabytes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Integer32  

fe827xCacheInstalled 1.3.6.1.4.1.2.6.118.4.1.1.3
The total amount of Cache memory installed on this blade. The amount is in units of Kbytes. This value is obtained from the card version level. Version 1 cards will have 256 Kbytes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Integer32  

fe827xFlashInstalled 1.3.6.1.4.1.2.6.118.4.1.1.4
The total amount of Flash memory installed on this blade. The amount is in units of Mbytes. This value is obtained from the Generic Status Register.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Integer32  

fe827xSRAMInstalled 1.3.6.1.4.1.2.6.118.4.1.1.5
The total amount of SRAM installed on this blade. The amount is in units of Mbytes. This value is obtained indirectly by reading MIMIC adapter version in the UFIC adapter ID register. Version 1 will have 1 Mbytes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Integer32  

fe827xNotifyStatus 1.3.6.1.4.1.2.6.118.4.1.1.6
The status of the trap reporting service in this MSS Client or MSS Domain Client variable shall assume a value of enabled(1) if this MSS Client or MSS Domain Client is permitted to send traps. This variable shall assume a value of disabled(2) if this MSS Client or MSS Domain Client is prohibited from sending traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

fe827xSwitchIPAddr 1.3.6.1.4.1.2.6.118.4.1.1.7
This is the IP address of the switch that the MSS Client or MSS Domain Client is plugged into.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fe827xSwitchSlotNum 1.3.6.1.4.1.2.6.118.4.1.1.8
This is the slot number of the switch that the MSS Client or MSS Domain Client is plugged into.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Integer32  

fe827xSwitchPortNum 1.3.6.1.4.1.2.6.118.4.1.1.9
This is the switch port number that the MSS Client or MSS Domain Client is associated with.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Integer32  

fe827xPCINumSlot 1.3.6.1.4.1.2.6.118.4.1.2.1
The number of PCI adapter slots available for this blade. At present this would assume a value 1, since there can be only one PCI adapter for the MSS Client. This value is zero for the MSS Domain Client since it does not support PCI adapters.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Integer32  

fe827xPCIAdapTable 1.3.6.1.4.1.2.6.118.4.1.2.2
A table of PCI adapters entries. The number of entries is given by the value of fe827xPCINumSlot. At present only one PCI adapter is supported by the MSS Client.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Fe827xPCIAdapEntry

fe827xPCIAdapEntry 1.3.6.1.4.1.2.6.118.4.1.2.2.1
A PCI adapter entry containing objects to describe the operational aspects of the PCI adapter on this blade.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Fe827xPCIAdapEntry  

fe827xPCIAdapSlotNum 1.3.6.1.4.1.2.6.118.4.1.2.2.1.1
The relative slot location at which the adapter is attached to this blade. At present slot is numbered as 1. This variable serves as the index for the 827xPCIAdapTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Integer32  

fe827xPCIAdapType 1.3.6.1.4.1.2.6.118.4.1.2.2.1.2
The type of PCI adapter that is inserted into this slot. This variable shall assume a value of unknown(1) if the fe827xPCIAdapConfigType is notConfigured(1) or if the fe827xPCIAdapConfigType is atm(2) and the fe827xPCIAdapOperStatus has a value of unknown(1), notConfigured(2), notPresent(3), unavailable(4), does-not_apply(5) or missConfigured (10). The variable shall assume a value of atm(2) if the fe827xPCIAdapConfigType has a value of atm(2) and the fe827xPCIAdapOperStatus has a value of enabled-pending(6), enabled(7), disabled-pending(8) or disabled(9).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), atm(2)  

fe827xPCIAdapConfigType 1.3.6.1.4.1.2.6.118.4.1.2.2.1.3
The router configuration type for this slot. The variable shall assume a value of notConfigured(1) if no configuration exist for this slot. The variable shall assume a value of atm(2) if the slot is configured for an ATM adapter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notConfigured(1), atm(2)  

fe827xPCIAdapATMMediaType 1.3.6.1.4.1.2.6.118.4.1.2.2.1.4
The type of fiber used by the ATM short PCI cards. The values for the media type could be Gemini or Multi-Mode Fiber mmf(2) and Meercat or Single Mode Fiber smf(3).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), smf(2), mmf(3)  

fe827xPCIAdapOperStatus 1.3.6.1.4.1.2.6.118.4.1.2.2.1.5
The operational status of this PCI adapter for the balde. The variable shall assume a value of unknown(1) if the adapter inserted in the slot cannot be recognized. The variable shall assume a value of notConfigured(2) if the adapter inserted in the slot is recognized but no router configuration exists. The variable shall assume a value of notPresent(3) if the adapter is not inserted in the slot but the router configuration exists. The variable shall assume a value of unavailable(4) if adapter inserted in the slot can not be used nor made ready to be used; for example, a hardware error. The variable shall assume a value of doesNotApply(5) if this adapter does not contain an operational state. The variable shall assume a value of enablePending(6) if commands have been issued to enable the adapter but have not been completed. The variable shall assume a value of enabled(7) if commands have been successfully issued to enable the adapter. The variable shall assume a value of disablePending(8) if commands have been issued to disable the adapter but have not been completed. The variable shall assume a value of disabled(9) if commands have been successfully issued to disable the adapter. The variable shall assume a value of missConfigured(10) if the adapter is inserted in the slot but the router configuration is of a different type. This object would also drive the Unit LED's.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), notConfigured(2), notPresent(3), unavailable(4), doesNotApply(5), enablePending(6), enabled(7), disablePending(8), disabled(9), missConfigured(10)  

fe827xPCIAdapDiagStatus 1.3.6.1.4.1.2.6.118.4.1.2.2.1.6
The diagnostic status of this PCI adapter for the blade. The variable shall assume a value of auto(1) if commands have been issued by the system to determine the status of the adapter; for example, at initialization. The variable shall assume a value of inactive(2) if the adapter is not currently running any diagnostics. The variable shall assume a value of idle(3) if the adapter is in the disabled operational state ready to run the diagnostics. The variable shall assume a value of active(4) if commands have been issued by the user to run the diagnostics.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER auto(1), inactive(2), idle(3), active(4)  

fe827xPCIAdapNetworkStatus 1.3.6.1.4.1.2.6.118.4.1.2.2.1.7
The network status of this PCI adapter in this blade The variable shall assume a value of up(1) if the adapter is connected to the network. The variable shall assume a value of down(3) if the adapter can not verify a network connection. The variable shall assume a value of testing(4) if the adapter is running tests for the network connection. The variable shall assume a value of unknown(1) if network status can not be determined. The variable shall assume a value of doesNotApply(5) if the adapter does not contain a network state.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), up(2), down(3), testing(4), doesNotApply(5)  

fe827xPCIAdapFaultStatus 1.3.6.1.4.1.2.6.118.4.1.2.2.1.8
The fault status of this PCI adapter in this blade. The variable shall assume a value of noFault(2) if no fault that is associated with this adapter has been detected. The variable shall assume a value of isolated(3) if this fault that can be isolated on the adapter itself. The variable shall assume a value of nonIsolated(4) if the fault can not isolated on the adapter or in the network. The variable shall assume a value of unknown(1) if the fault status has not been determined; for example, at initialization. This object would drive the port LED's also. status noFault(2) indicates LED green other values indicate port LED yellow.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), noFault(2), isolated(3), nonIsolated(4)  

fe827xStatTable 1.3.6.1.4.1.2.6.118.4.1.3.1
A table of the statistics for each queue on the MSS Client or MSS Domain Client.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Fe827xStatEntry

fe827xStatEntry 1.3.6.1.4.1.2.6.118.4.1.3.1.1
A statistic entry containing objects to describe the aspects of the queue's on the MSS Client or MSS Domain Client.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Fe827xStatEntry  

fe827xStatQueueNum 1.3.6.1.4.1.2.6.118.4.1.3.1.1.1
The queue number on the Forwarding Engine. This variable serves as the index for the fe827xStatTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Integer32  

fe827xStatFramesSent 1.3.6.1.4.1.2.6.118.4.1.3.1.1.2
A count of frames sent on the queue.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

fe827xStatFramesReceived 1.3.6.1.4.1.2.6.118.4.1.3.1.1.3
A count of frames received on the queue.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

fe827xDomainIfTable 1.3.6.1.4.1.2.6.118.4.1.4.1
A table for mapping MSS Client or MSS Domain Client interface numbers to Switch Domain numbers.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Fe827xDomainIfEntry

fe827xDomainIfEntry 1.3.6.1.4.1.2.6.118.4.1.4.1.1
Each entry maps a single MSS Client or MSS Domain Client interface number to a single Switch Domain numbers.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Fe827xDomainIfEntry  

fe827xSwitchDomainNum 1.3.6.1.4.1.2.6.118.4.1.4.1.1.1
Switches Domain Number associated with this MSS Client or MSS Domain Client Interface Number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Integer32  

fe827xPCIAdapStatusChg 1
The trap announces a change in the status of the PCI adapter. It shall be sent if the value of either fe827xPCIAdapOperType, fe827xPCIAdapDiagStatus, fe827xPCIAdapNetworkStatus, or fe827xPCIAdapFaultStatus changes and fe827xNotifyStatus has a value of enabled(1).
TRAP-TYPE    

feGroup 1.3.6.1.4.1.2.6.118.4.2.1.1
OBJECT IDENTIFIER    

feMIBCompliance 1.3.6.1.4.1.2.6.118.4.2.2.1
OBJECT IDENTIFIER