FRAMEVISIONFPING-MIB

File: FRAMEVISIONFPING-MIB.mib (11597 bytes)

Imported modules

RFC1155-SMI RFC-1212

Imported symbols

enterprises IpAddress Counter
TimeTicks OBJECT-TYPE

Defined Types

FribDLCI  
INTEGER 0..2147483646    

Counter32  
Counter    

FpingAutoCfgEntry  
SEQUENCE    
  fpingAutoCfgIfIndex INTEGER
  fpingAutoCfgLastChange TimeTicks
  fpingAutoCfgGen INTEGER
  fpingAutoCfgThresh INTEGER
  fpingAutoCfgReset INTEGER

FpingAutoEntry  
SEQUENCE    
  fpingAutoIfIndex INTEGER
  fpingAutoDLCI FribDLCI
  fpingAutoDelayMin INTEGER
  fpingAutoDelayMax INTEGER
  fpingAutoDelayAvg INTEGER
  fpingAutoLost Counter32
  fpingAutoTotal Counter32
  fpingAutoThreshExceeded Counter32
  fpingAutoRmtDLCI FribDLCI
  fpingAutoRmtIpaddr IpAddress
  fpingAutoTotalPktsLocalTx Counter32
  fpingAutoTotalPktsLocalRx Counter32
  fpingAutoTotalPktsRmtTx Counter32
  fpingAutoTotalPktsRmtRx Counter32
  fpingAutoStatus INTEGER
  fpingAutoFailedEvents Counter32

FpingManualEntry  
SEQUENCE    
  fpingManualIfIndex INTEGER
  fpingManualDLCI FribDLCI
  fpingManualAction INTEGER
  fpingManualState INTEGER
  fpingManualFreq INTEGER
  fpingManualLen INTEGER
  fpingManualCur INTEGER
  fpingManualMin INTEGER
  fpingManualMax INTEGER
  fpingManualAvg INTEGER
  fpingManualLost INTEGER
  fpingManualTotal INTEGER
  fpingManualRmtDLCI FribDLCI
  fpingManualRmtIpaddr IpAddress

Defined Values

framevisionfping 1.3.6.1.4.1.181.100.2
OBJECT IDENTIFIER    

fpingMib 1.3.6.1.4.1.181.100.2.1
OBJECT IDENTIFIER    

fpingAuto 1.3.6.1.4.1.181.100.2.2
OBJECT IDENTIFIER    

fpingManual 1.3.6.1.4.1.181.100.2.3
OBJECT IDENTIFIER    

fpingMibVersion 1.3.6.1.4.1.181.100.2.1.1
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER version1(1)  

fpingMibLastChange 1.3.6.1.4.1.181.100.2.1.2
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

fpingAutoCfgTable 1.3.6.1.4.1.181.100.2.2.1
.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FpingAutoCfgEntry

fpingAutoCfgEntry 1.3.6.1.4.1.181.100.2.2.1.1
.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FpingAutoCfgEntry  

fpingAutoCfgIfIndex 1.3.6.1.4.1.181.100.2.2.1.1.1
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fpingAutoCfgLastChange 1.3.6.1.4.1.181.100.2.2.1.1.2
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

fpingAutoCfgGen 1.3.6.1.4.1.181.100.2.2.1.1.3
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

fpingAutoCfgThresh 1.3.6.1.4.1.181.100.2.2.1.1.4
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

fpingAutoCfgReset 1.3.6.1.4.1.181.100.2.2.1.1.5
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER fpingResetIdle(1), fpingResetStart(2)  

fpingAutoDuration 1.3.6.1.4.1.181.100.2.2.2
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

fpingAutoClearData 1.3.6.1.4.1.181.100.2.2.3
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER clearDataIdle(1), clearDataStart(2)  

fpingAutoTable 1.3.6.1.4.1.181.100.2.2.4
.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FpingAutoEntry

fpingAutoEntry 1.3.6.1.4.1.181.100.2.2.4.1
.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FpingAutoEntry  

fpingAutoIfIndex 1.3.6.1.4.1.181.100.2.2.4.1.1
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fpingAutoDLCI 1.3.6.1.4.1.181.100.2.2.4.1.2
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  FribDLCI  

fpingAutoDelayMin 1.3.6.1.4.1.181.100.2.2.4.1.3
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fpingAutoDelayMax 1.3.6.1.4.1.181.100.2.2.4.1.4
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fpingAutoDelayAvg 1.3.6.1.4.1.181.100.2.2.4.1.5
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fpingAutoLost 1.3.6.1.4.1.181.100.2.2.4.1.6
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

fpingAutoTotal 1.3.6.1.4.1.181.100.2.2.4.1.7
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

fpingAutoThreshExceeded 1.3.6.1.4.1.181.100.2.2.4.1.8
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

fpingAutoRmtDLCI 1.3.6.1.4.1.181.100.2.2.4.1.9
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  FribDLCI  

fpingAutoRmtIpaddr 1.3.6.1.4.1.181.100.2.2.4.1.10
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fpingAutoTotalPktsLocalTx 1.3.6.1.4.1.181.100.2.2.4.1.11
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

fpingAutoTotalPktsLocalRx 1.3.6.1.4.1.181.100.2.2.4.1.12
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

fpingAutoTotalPktsRmtTx 1.3.6.1.4.1.181.100.2.2.4.1.13
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

fpingAutoTotalPktsRmtRx 1.3.6.1.4.1.181.100.2.2.4.1.14
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

fpingAutoStatus 1.3.6.1.4.1.181.100.2.2.4.1.15
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER fpingDisabled(1), lastFpingSucceeded(2), lastFpingFailed(3), notMonitoringFping(4), waitingToStartFping(5)  

fpingAutoFailedEvents 1.3.6.1.4.1.181.100.2.2.4.1.16
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

fpingManualTable 1.3.6.1.4.1.181.100.2.3.1
.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FpingManualEntry

fpingManualEntry 1.3.6.1.4.1.181.100.2.3.1.1
.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FpingManualEntry  

fpingManualIfIndex 1.3.6.1.4.1.181.100.2.3.1.1.1
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fpingManualDLCI 1.3.6.1.4.1.181.100.2.3.1.1.2
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  FribDLCI  

fpingManualAction 1.3.6.1.4.1.181.100.2.3.1.1.3
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER fpingManualActionStart(1), fpingManualActionStop(2)  

fpingManualState 1.3.6.1.4.1.181.100.2.3.1.1.4
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER fpingManualStateIdle(1), fpingManualStateOtherStart(2), fpingManualStarteRunning(3)  

fpingManualFreq 1.3.6.1.4.1.181.100.2.3.1.1.5
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

fpingManualLen 1.3.6.1.4.1.181.100.2.3.1.1.6
.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

fpingManualCur 1.3.6.1.4.1.181.100.2.3.1.1.7
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fpingManualMin 1.3.6.1.4.1.181.100.2.3.1.1.8
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fpingManualMax 1.3.6.1.4.1.181.100.2.3.1.1.9
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fpingManualAvg 1.3.6.1.4.1.181.100.2.3.1.1.10
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fpingManualLost 1.3.6.1.4.1.181.100.2.3.1.1.11
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fpingManualTotal 1.3.6.1.4.1.181.100.2.3.1.1.12
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fpingManualRmtDLCI 1.3.6.1.4.1.181.100.2.3.1.1.13
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  FribDLCI  

fpingManualRmtIpaddr 1.3.6.1.4.1.181.100.2.3.1.1.14
.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress