FspR7-SPEQ-MIB

File: FspR7-SPEQ-MIB.mib (28680 bytes)

Imported modules

SNMPv2-TC SNMPv2-CONF SNMPv2-SMI
SNMP-FRAMEWORK-MIB ADVA-MIB FspR7-MIB

Imported symbols

DisplayString TestAndIncr TimeStamp
RowStatus DateAndTime TruthValue
TEXTUAL-CONVENTION MODULE-COMPLIANCE NOTIFICATION-GROUP
OBJECT-GROUP Counter32 MODULE-IDENTITY
NOTIFICATION-TYPE OBJECT-TYPE OBJECT-IDENTITY
TimeTicks mib-2 snmpModules
enterprises Unsigned32 Integer32
IpAddress SnmpAdminString fspR7
EntityClass EntityIndex TrapAlarmSeverity
ServiceImpairment neEventLogTimeStamp neEventLogIdentityTranslation
FspR7AdminState FspR7AdminStateCaps FspR7EntitySecondaryStates
FspR7Integer32Caps FspR7OperState

Defined Types

FspR7SpeqConfig  
Auto Span Equalization Configuration
TEXTUAL-CONVENTION    
  INTEGER undefined(0), none(1), disable(2), enableGainAdopt(3), enableNoGainAdopt(4)  

FspR7SpeqDisableEnable  
SPEQ Dynamic Compensation for span optical power variations.
TEXTUAL-CONVENTION    
  INTEGER undefined(0), enable(1), disable(2)  

FspR7SpeqFarEndConfig  
Indicating Far-End Auto Span Equalization Configuration.
TEXTUAL-CONVENTION    
  INTEGER undefined(0), unknown(1), enable(2), disable(3)  

FspR7SpeqOperate  
When Per-Channel Power (PPC) changes without an SPEQ trigger condition; users could use this command to invoke SPEQ Gain recalculation/setting on the associated EDFA. (SPEQ Gain recalculation shall inherit the current value of the GainCal.) This user operated action could be service effecting. Therefore, users must be warned when operating this command; only upon user acceptance, software shall proceed with the new Gain recalculation and setting.
TEXTUAL-CONVENTION    
  INTEGER undefined(0), rls(1), opr(2)  

FspR7SpeqOperateCaps  
When Per-Channel Power (PPC) changes without an SPEQ trigger condition; users could use this command to invoke SPEQ Gain recalculation/setting on the associated EDFA. (SPEQ Gain recalculation shall inherit the current value of the GainCal.) This user operated action could be service effecting. Therefore, users must be warned when operating this command; only upon user acceptance, software shall proceed with the new Gain recalculation and setting.
TEXTUAL-CONVENTION    
  BITS capUndefined(0), capRls(1), capOpr(2)  

FspR7SpeqQualify  
Determines if the qualified EDFA has been configured as Per-Amp, Booster-Amp, Line-Amp. Qualification process requires valid fiber-map.
TEXTUAL-CONVENTION    
  INTEGER undefined(0), preAmp(1), boosterAmp(2), lineAmp(3)  

FspR7SpeqOptLineService  
This parameter provides optical channel service types that are being transported to/from an optical line. See related generic group or YP for the specific usage and/or explanation.
TEXTUAL-CONVENTION    
  INTEGER undefined(0), addDrop(1), passThrough(2), hybrid(3)  

FspR7SpeqPpcLimit  
Per-channel optical power limit value for supporting the maximum channel operation of a given optical link. PPC-LIMIT for an optical link with the 40 or the 80 max channel operations would be 4dBm or 1dBm respectively. Example: assuming a user has installed an EFDA with Output Power of 20 interfacing an optical link with the max channel operation/capacity of 40. Therefore, PPC-LIMIT (the optimum power per-channel setting) for this link is 4dBm (PT=10log(n)+PPC; where PT=Total Output Power of the EDFA=20dB, n=max channel operation=40, PPC=PPC-LIMIT).
TEXTUAL-CONVENTION    
  INTEGER undefined(0), four(1), one(2), seven(3)  

FspR7SpeqStatus  
Auto Span Equalization Status
TEXTUAL-CONVENTION    
  INTEGER undefined(0), none(1), inProgress(2), lockedOut(3)  

FspR7SpeqStandingConditionTypes  
Tok_String
TEXTUAL-CONVENTION    
  INTEGER undefined(0), oosDisabledSpeq(120000), oosMaintenanceSpeq(120002), messageLossSpeq(120004), oscFiberMissingSpeq(120005), optLowSpeq(120006), ppcOutOfRangeSpeq(120007), gainTooHighSpeq(120008), gainTooLowSpeq(120009), gainAdoptFailedSpeq(120010)  

SpeqEntityEntry  
SEQUENCE    
  speqEntityIndex EntityIndex
  speqEntityContainedIn EntityIndex
  speqEntityClassInstanceNumber Integer32
  speqEntityIndexAid SnmpAdminString

SpeqContainsEntry  
SEQUENCE    
  speqContainsIndex EntityIndex

SpeqConfigEntry  
SEQUENCE    
  speqConfigAdmin FspR7AdminState
  speqConfigOpticalSetpoint Integer32
  speqConfigPerChannelPower Integer32
  speqConfigGainCal Integer32
  speqConfigOperate FspR7SpeqOperate

SpeqConfigCapEntry  
SEQUENCE    
  speqConfigCapAdmin FspR7AdminStateCaps
  speqConfigCapOpticalSetpoint FspR7Integer32Caps
  speqConfigCapPerChannelPower FspR7Integer32Caps
  speqConfigCapGainCal FspR7Integer32Caps

SpeqStatusEntry  
SEQUENCE    
  speqStatusOper FspR7OperState
  speqStatusSecondaryStates FspR7EntitySecondaryStates
  speqStatusQualify FspR7SpeqQualify
  speqStatusOpticalLineAid EntityIndex
  speqStatusOscAid EntityIndex
  speqStatusOpticalLineServiceType FspR7SpeqOptLineService
  speqStatusPerChannelPowerLimit FspR7SpeqPpcLimit
  speqStatusCalculatedGain Unsigned32
  speqStatusStatus FspR7SpeqStatus
  speqStatusFarEndConfig FspR7SpeqFarEndConfig
  speqStatusFarEndStatus FspR7SpeqStatus
  speqStatusFarEndPpc Integer32
  speqStatusFarEndOpt Integer32
  speqStatusFarEndOpr Integer32
  speqStatusNearEndOpt Integer32
  speqStatusNearEndOpr Integer32

SpeqConditionSeverityEntry  
SEQUENCE    
  speqConditionSeverityType FspR7SpeqStandingConditionTypes
  speqConditionSeverityValue TrapAlarmSeverity

SpeqCurrentConditionEntry  
SEQUENCE    
  speqCurrentConditionType FspR7SpeqStandingConditionTypes
  speqCurrentConditionSeverity TrapAlarmSeverity
  speqCurrentConditionAffect ServiceImpairment
  speqCurrentConditionTimeStamp DateAndTime

Defined Values

speqMIB 1.3.6.1.4.1.2544.1.11.4
The Auto SPAN Equalization MIB.
MODULE-IDENTITY    

speqEntityMIB 1.3.6.1.4.1.2544.1.11.4.10
OBJECT IDENTIFIER    

speqConfigurationMIB 1.3.6.1.4.1.2544.1.11.4.12
OBJECT IDENTIFIER    

speqStatusMIB 1.3.6.1.4.1.2544.1.11.4.13
OBJECT IDENTIFIER    

speqAlarms 1.3.6.1.4.1.2544.1.11.4.14
OBJECT IDENTIFIER    

speqTraps 1.3.6.1.4.1.2544.1.11.4.14.1
OBJECT IDENTIFIER    

speqTrapsPrefix 1.3.6.1.4.1.2544.1.11.4.14.1.0
OBJECT IDENTIFIER    

speqConditions 1.3.6.1.4.1.2544.1.11.4.14.2
OBJECT IDENTIFIER    

speqEntityTable 1.3.6.1.4.1.2544.1.11.4.10.1
Table for SPEQ existing addresses. Entities in this table are either provisioned or not. Containers are always present in the table as long as their supporting entity is provisioned.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SpeqEntityEntry

speqEntityEntry 1.3.6.1.4.1.2544.1.11.4.10.1.1
Entry for SPEQ existing addresses.
Status: current Access: not-accessible
OBJECT-TYPE    
  SpeqEntityEntry  

speqEntityIndex 1.3.6.1.4.1.2544.1.11.4.10.1.1.1
Existing adress index
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  EntityIndex  

speqEntityContainedIn 1.3.6.1.4.1.2544.1.11.4.10.1.1.2
Contained in
Status: current Access: read-only
OBJECT-TYPE    
  EntityIndex  

speqEntityClassInstanceNumber 1.3.6.1.4.1.2544.1.11.4.10.1.1.3
The class instance number of this entity within the module(card)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..2000 | -2147483648  

speqEntityIndexAid 1.3.6.1.4.1.2544.1.11.4.10.1.1.4
Name
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString  

speqContainsTable 1.3.6.1.4.1.2544.1.11.4.10.2
Table for all existing addresses. Gives the index of the subtending entity in the containment.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SpeqContainsEntry

speqContainsEntry 1.3.6.1.4.1.2544.1.11.4.10.2.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SpeqContainsEntry  

speqContainsIndex 1.3.6.1.4.1.2544.1.11.4.10.2.1.1
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  EntityIndex  

speqConfiguration 1.3.6.1.4.1.2544.1.11.4.12.1
Tok_String
Status: current Access: read-write
OBJECT-TYPE    
  FspR7SpeqConfig  

speqDynamicComp 1.3.6.1.4.1.2544.1.11.4.12.2
Tok_String
Status: current Access: read-write
OBJECT-TYPE    
  FspR7SpeqDisableEnable  

speqConfigTable 1.3.6.1.4.1.2544.1.11.4.12.10
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SpeqConfigEntry

speqConfigEntry 1.3.6.1.4.1.2544.1.11.4.12.10.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SpeqConfigEntry  

speqConfigAdmin 1.3.6.1.4.1.2544.1.11.4.12.10.1.1
Tok_String
Status: current Access: read-write
OBJECT-TYPE    
  FspR7AdminState  

speqConfigOpticalSetpoint 1.3.6.1.4.1.2544.1.11.4.12.10.1.2
Tok_String
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -250..50 | -2147483648  

speqConfigPerChannelPower 1.3.6.1.4.1.2544.1.11.4.12.10.1.3
Tok_String
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -20..80 | -2147483648  

speqConfigGainCal 1.3.6.1.4.1.2544.1.11.4.12.10.1.4
Tok_String
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -50..50 | -2147483648  

speqConfigOperate 1.3.6.1.4.1.2544.1.11.4.12.10.1.5
Tok_String
Status: current Access: read-write
OBJECT-TYPE    
  FspR7SpeqOperate  

speqConfigCapTable 1.3.6.1.4.1.2544.1.11.4.12.11
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SpeqConfigCapEntry

speqConfigCapEntry 1.3.6.1.4.1.2544.1.11.4.12.11.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SpeqConfigCapEntry  

speqConfigCapAdmin 1.3.6.1.4.1.2544.1.11.4.12.11.1.1
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  FspR7AdminStateCaps  

speqConfigCapOpticalSetpoint 1.3.6.1.4.1.2544.1.11.4.12.11.1.2
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  FspR7Integer32Caps  

speqConfigCapPerChannelPower 1.3.6.1.4.1.2544.1.11.4.12.11.1.3
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  FspR7Integer32Caps  

speqConfigCapGainCal 1.3.6.1.4.1.2544.1.11.4.12.11.1.4
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  FspR7Integer32Caps  

speqStatusTable 1.3.6.1.4.1.2544.1.11.4.13.10
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SpeqStatusEntry

speqStatusEntry 1.3.6.1.4.1.2544.1.11.4.13.10.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SpeqStatusEntry  

speqStatusOper 1.3.6.1.4.1.2544.1.11.4.13.10.1.1
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  FspR7OperState  

speqStatusSecondaryStates 1.3.6.1.4.1.2544.1.11.4.13.10.1.2
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  FspR7EntitySecondaryStates  

speqStatusQualify 1.3.6.1.4.1.2544.1.11.4.13.10.1.3
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  FspR7SpeqQualify  

speqStatusOpticalLineAid 1.3.6.1.4.1.2544.1.11.4.13.10.1.4
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  EntityIndex  

speqStatusOscAid 1.3.6.1.4.1.2544.1.11.4.13.10.1.5
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  EntityIndex  

speqStatusOpticalLineServiceType 1.3.6.1.4.1.2544.1.11.4.13.10.1.6
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  FspR7SpeqOptLineService  

speqStatusPerChannelPowerLimit 1.3.6.1.4.1.2544.1.11.4.13.10.1.7
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  FspR7SpeqPpcLimit  

speqStatusCalculatedGain 1.3.6.1.4.1.2544.1.11.4.13.10.1.8
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

speqStatusStatus 1.3.6.1.4.1.2544.1.11.4.13.10.1.9
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  FspR7SpeqStatus  

speqStatusFarEndConfig 1.3.6.1.4.1.2544.1.11.4.13.10.1.10
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  FspR7SpeqFarEndConfig  

speqStatusFarEndStatus 1.3.6.1.4.1.2544.1.11.4.13.10.1.11
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  FspR7SpeqStatus  

speqStatusFarEndPpc 1.3.6.1.4.1.2544.1.11.4.13.10.1.12
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

speqStatusFarEndOpt 1.3.6.1.4.1.2544.1.11.4.13.10.1.13
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

speqStatusFarEndOpr 1.3.6.1.4.1.2544.1.11.4.13.10.1.14
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

speqStatusNearEndOpt 1.3.6.1.4.1.2544.1.11.4.13.10.1.15
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

speqStatusNearEndOpr 1.3.6.1.4.1.2544.1.11.4.13.10.1.16
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

alarmOosDisabledSpeq 1.3.6.1.4.1.2544.1.11.4.14.1.0.120000
Non-Specific Disablement of Management Access
Status: current Access: read-only
NOTIFICATION-TYPE    

alarmOosMaintenanceSpeq 1.3.6.1.4.1.2544.1.11.4.14.1.0.120002
Alarms are logged but not notified, service affecting changes and operations are permitted
Status: current Access: read-only
NOTIFICATION-TYPE    

alarmMessageLossSpeq 1.3.6.1.4.1.2544.1.11.4.14.1.0.120004
SPEQ Message Loss
Status: current Access: read-only
NOTIFICATION-TYPE    

alarmOscFiberMissingSpeq 1.3.6.1.4.1.2544.1.11.4.14.1.0.120005
SPEQ not functioning, OSC Fiber(s) missing
Status: current Access: read-only
NOTIFICATION-TYPE    

alarmOptLowSpeq 1.3.6.1.4.1.2544.1.11.4.14.1.0.120006
Alarm is raised at SPEQ Booster-amp, when the OPT is less than the provisioned PPC by 2dBm.
Status: current Access: read-only
NOTIFICATION-TYPE    

alarmPpcOutOfRangeSpeq 1.3.6.1.4.1.2544.1.11.4.14.1.0.120007
Adopted PPC exceeded the PPC range
Status: current Access: read-only
NOTIFICATION-TYPE    

alarmGainTooHighSpeq 1.3.6.1.4.1.2544.1.11.4.14.1.0.120008
Auto Span Equalization Gain Out-of-Range, High - SPEQ calculated gain value is greater than the gain setting range of an EDFA type.
Status: current Access: read-only
NOTIFICATION-TYPE    

alarmGainTooLowSpeq 1.3.6.1.4.1.2544.1.11.4.14.1.0.120009
Auto Span Equalization Gain Out-of-Range, Low - SPEQ calculated gain value is lower than the gain setting range of an EDFA type.
Status: current Access: read-only
NOTIFICATION-TYPE    

alarmGainAdoptFailedSpeq 1.3.6.1.4.1.2544.1.11.4.14.1.0.120010
Alarm is raised when SPEQ Gain Adoption process fails.
Status: current Access: read-only
NOTIFICATION-TYPE    

speqCreation 1.3.6.1.4.1.2544.1.11.4.14.1.0.124001
This trap is sent every time an entity is created. No containers or other sub-entities in the chassis are reported created by this trap, the NMS must read these data.
Status: current Access: read-only
NOTIFICATION-TYPE    

speqDeletion 1.3.6.1.4.1.2544.1.11.4.14.1.0.124002
This trap is sent every time an entity is deleted. The sub-entities (containers, modules, etc.) are not reported deleted.
Status: current Access: read-only
NOTIFICATION-TYPE    

speqStateChange 1.3.6.1.4.1.2544.1.11.4.14.1.0.124003
This trap is sent when an entity state is changed.
Status: current Access: read-only
NOTIFICATION-TYPE    

speqObjectChange 1.3.6.1.4.1.2544.1.11.4.14.1.0.124004
This trap is sent when some object is changed.
Status: current Access: read-only
NOTIFICATION-TYPE    

transientGainAutoAdjustSpeq 1.3.6.1.4.1.2544.1.11.4.14.1.0.126000
Span Equalization Gain auto adjustment is triggered by monitoring LOS clear condition.
Status: current Access: read-only
NOTIFICATION-TYPE    

transientGainNoAdjustSpeq 1.3.6.1.4.1.2544.1.11.4.14.1.0.126001
Span Equalization Gain Not Adjusted.
Status: current Access: read-only
NOTIFICATION-TYPE    

transientGainAdjustFailedSpeq 1.3.6.1.4.1.2544.1.11.4.14.1.0.126002
Span Equalization Gain Adjustment Failed.
Status: current Access: read-only
NOTIFICATION-TYPE    

transientWaitSpeq 1.3.6.1.4.1.2544.1.11.4.14.1.0.126003
Auto Span Equalization is in progress; SPEQ-Server is busy, user must wait then request Span Equalization.
Status: current Access: read-only
NOTIFICATION-TYPE    

transientDenySpeq 1.3.6.1.4.1.2544.1.11.4.14.1.0.126004
Span Equalization request denied; operation could not be performed by the SPEQ-Server
Status: current Access: read-only
NOTIFICATION-TYPE    

transientPpcAdoptSpeq 1.3.6.1.4.1.2544.1.11.4.14.1.0.126005
PPC is auto calculated based on the adopted Gain for Brown-Field installations.
Status: current Access: read-only
NOTIFICATION-TYPE    

transientPpcLimitExceededSpeq 1.3.6.1.4.1.2544.1.11.4.14.1.0.126006
Provisioned per-channel power level exceeded the allowable limit
Status: current Access: read-only
NOTIFICATION-TYPE    

transientGainDynamicAdjustSpeq 1.3.6.1.4.1.2544.1.11.4.14.1.0.126007
Span Equalization Gain auto adjustment is triggered by dynamic optical power drift at Rx of the associated EDFA.
Status: current Access: read-only
NOTIFICATION-TYPE    

speqConditionSeverityTable 1.3.6.1.4.1.2544.1.11.4.14.2.1
This table contains a severity value for each defined standing condition reported by an entity in the NE.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SpeqConditionSeverityEntry

speqConditionSeverityEntry 1.3.6.1.4.1.2544.1.11.4.14.2.1.1
Each entry in the table represents the severity assigned to a condition.'
Status: current Access: not-accessible
OBJECT-TYPE    
  SpeqConditionSeverityEntry  

speqConditionSeverityType 1.3.6.1.4.1.2544.1.11.4.14.2.1.1.1
This object identifies the type of alarm.
Status: current Access: not-accessible
OBJECT-TYPE    
  FspR7SpeqStandingConditionTypes  

speqConditionSeverityValue 1.3.6.1.4.1.2544.1.11.4.14.2.1.1.2
This object identifies the severity assigned to this alarm.
Status: current Access: read-write
OBJECT-TYPE    
  TrapAlarmSeverity  

speqCurrentConditionTable 1.3.6.1.4.1.2544.1.11.4.14.2.2
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SpeqCurrentConditionEntry

speqCurrentConditionEntry 1.3.6.1.4.1.2544.1.11.4.14.2.2.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SpeqCurrentConditionEntry  

speqCurrentConditionType 1.3.6.1.4.1.2544.1.11.4.14.2.2.1.1
List of all interface conditions
Status: current Access: not-accessible
OBJECT-TYPE    
  FspR7SpeqStandingConditionTypes  

speqCurrentConditionSeverity 1.3.6.1.4.1.2544.1.11.4.14.2.2.1.2
This object identifies the current severity of alarm.
Status: current Access: read-only
OBJECT-TYPE    
  TrapAlarmSeverity  

speqCurrentConditionAffect 1.3.6.1.4.1.2544.1.11.4.14.2.2.1.3
This object indicates the service impairment affect of the alarm.
Status: current Access: read-only
OBJECT-TYPE    
  ServiceImpairment  

speqCurrentConditionTimeStamp 1.3.6.1.4.1.2544.1.11.4.14.2.2.1.4
Timestamp
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime