G6-HARDWARE-MIB

File: G6-HARDWARE-MIB.mib (36014 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC MICROSENS-G6-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Integer32
Unsigned32 Counter32 enterprises
NOTIFICATION-TYPE DisplayString MacAddress
g6

Defined Types

CableTestConfigEntry  
SEQUENCE    
  cableTestConfigPortIndex INTEGER
  cableTestConfigEnableAutoCableTest INTEGER
  cableTestConfigEventGeneration INTEGER
  cableTestConfigStartTestNow DisplayString

IoSignalConfigEntry  
SEQUENCE    
  ioSignalConfigIndex INTEGER
  ioSignalConfigSignalMode INTEGER
  ioSignalConfigInput1Mode INTEGER
  ioSignalConfigInput1Name DisplayString
  ioSignalConfigInput2Mode INTEGER
  ioSignalConfigInput2Name DisplayString
  ioSignalConfigOutput1Trigger INTEGER
  ioSignalConfigOutput1Name DisplayString
  ioSignalConfigOutput2Trigger INTEGER
  ioSignalConfigOutput2Name DisplayString

ModuleInfoEntry  
SEQUENCE    
  moduleInfoIndex INTEGER
  moduleInfoUnitType INTEGER
  moduleInfoArticleNumber DisplayString
  moduleInfoSerialNumber DisplayString
  moduleInfoHardwareVersion DisplayString
  moduleInfoProjectNumber DisplayString
  moduleInfoOccupiedSlots DisplayString
  moduleInfoDescription DisplayString

SlotInfoEntry  
SEQUENCE    
  slotInfoIndex INTEGER
  slotInfoBoardType INTEGER
  slotInfoBoardId Unsigned32
  slotInfoVersionBits Integer32

PortInfoEntry  
SEQUENCE    
  portInfoPortIndex INTEGER
  portInfoSystemSlot Integer32
  portInfoSwitchPort Integer32
  portInfoUserSlot Integer32
  portInfoUserPort Integer32
  portInfoSnmpPort Integer32
  portInfoSnmpInstance Integer32
  portInfoHardwarePort Integer32
  portInfoInterfaceType INTEGER
  portInfoProperties BITS

PortLedsEntry  
SEQUENCE    
  portLedsPortIndex INTEGER
  portLedsEthernetColor INTEGER
  portLedsEthernetBlinking INTEGER
  portLedsPoeColor INTEGER
  portLedsPoeBlinking INTEGER

DeviceLedsEntry  
SEQUENCE    
  deviceLedsIndex INTEGER
  deviceLedsSystem1Color INTEGER
  deviceLedsSystem1Blinking INTEGER
  deviceLedsSystem2Color INTEGER
  deviceLedsSystem2Blinking INTEGER
  deviceLedsPowerOn1Color INTEGER
  deviceLedsPowerOn1Blinking INTEGER
  deviceLedsPowerOn2Color INTEGER
  deviceLedsPowerOn2Blinking INTEGER
  deviceLedsRing1Color INTEGER
  deviceLedsRing1Blinking INTEGER
  deviceLedsRing2Color INTEGER
  deviceLedsRing2Blinking INTEGER
  deviceLedsSignalIn1Color INTEGER
  deviceLedsSignalIn1Blinking INTEGER
  deviceLedsSignalIn2Color INTEGER
  deviceLedsSignalIn2Blinking INTEGER
  deviceLedsSignalOut1Color INTEGER
  deviceLedsSignalOut1Blinking INTEGER
  deviceLedsSignalOut2Color INTEGER
  deviceLedsSignalOut2Blinking INTEGER

CableTestStatusEntry  
SEQUENCE    
  cableTestStatusPortIndex INTEGER
  cableTestStatusUpdateTimeStamp DisplayString
  cableTestStatusPair0State INTEGER
  cableTestStatusPair0DistanceToFault Integer32
  cableTestStatusPair1State INTEGER
  cableTestStatusPair1DistanceToFault Integer32
  cableTestStatusPair2State INTEGER
  cableTestStatusPair2DistanceToFault Integer32
  cableTestStatusPair3State INTEGER
  cableTestStatusPair3DistanceToFault Integer32
  cableTestStatusCableStatus INTEGER

IoSignalStatusEntry  
SEQUENCE    
  ioSignalStatusIndex INTEGER
  ioSignalStatusInput1AlarmActive INTEGER
  ioSignalStatusInput2AlarmActive INTEGER
  ioSignalStatusOutput1RelayActive INTEGER
  ioSignalStatusOutput2RelayActive INTEGER

TcamStatusEntry  
SEQUENCE    
  tcamStatusIndex INTEGER
  tcamStatusControlFile DisplayString
  tcamStatusDescription DisplayString

Defined Values

device 1.3.6.1.4.1.3181.10.6.1
Microsens private MIB for Generation 6 Ethernet Switches
MODULE-IDENTITY    

hardware 1.3.6.1.4.1.3181.10.6.1.31
OBJECT IDENTIFIER    

hardwareLedTest 1.3.6.1.4.1.3181.10.6.1.31.1
Runs a leds test whereby all LED light up in all possible colors for checking their function. The tests terminates within a few seconds.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

hardwareLedMode 1.3.6.1.4.1.3181.10.6.1.31.2
The LED display can be configured to be less intrusive.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER dynamic(0), static(1), quiet(2), dark(3), lightshow(4)  

hardwarePowerSupply1Monitored 1.3.6.1.4.1.3181.10.6.1.31.3
When disabled a missing power supply 1 will not turn the associated led red on failure. Do this when single power supply 2 operation is used or when the device is powered soley by PoE. This feature only applies to industrial switches.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

hardwarePowerSupply2Monitored 1.3.6.1.4.1.3181.10.6.1.31.4
When disabled a missing power supply 2 will not turn the associated led red on failure. Do this when single power supply 1 operation is used or when the device is powered soley by PoE. This feature only applies to industrial switches.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

hardwareFactoryResetButton 1.3.6.1.4.1.3181.10.6.1.31.5
When disabled the factory button will trigger the factory reset function when pressed for a long time. The IP discover function upon a short button click is not affected.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

cableTestConfigTable 1.3.6.1.4.1.3181.10.6.1.31.6
The cable tester allows for detection of copper cable faults and can even detect where the fault is located.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CableTestConfigEntry

cableTestConfigEntry 1.3.6.1.4.1.3181.10.6.1.31.6.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  CableTestConfigEntry  

cableTestConfigPortIndex 1.3.6.1.4.1.3181.10.6.1.31.6.1.1
Automatically generated
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..24  

cableTestConfigEnableAutoCableTest 1.3.6.1.4.1.3181.10.6.1.31.6.1.2
When enabled a cable test is performed each time the link goes down. The test is only performed for copper ports or dual media ports in copper mode.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

cableTestConfigEventGeneration 1.3.6.1.4.1.3181.10.6.1.31.6.1.3
When the cable termination status changes an event can be raised.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), anyChange(1), cableUnplugged(2)  

cableTestConfigStartTestNow 1.3.6.1.4.1.3181.10.6.1.31.6.1.4
May be used to manually start a cable test. ATTENTION: If the port is in link up status it will be forced to link down first. This will disrupt the current data traffic. Therefore, type start_test_now = CONFIRM.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

ioSignalConfigTable 1.3.6.1.4.1.3181.10.6.1.31.7
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IoSignalConfigEntry

ioSignalConfigEntry 1.3.6.1.4.1.3181.10.6.1.31.7.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  IoSignalConfigEntry  

ioSignalConfigIndex 1.3.6.1.4.1.3181.10.6.1.31.7.1.1
Automatically generated
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0  

ioSignalConfigSignalMode 1.3.6.1.4.1.3181.10.6.1.31.7.1.2
Permit setting of io signal LEDs and relays to static or blink blink mode for increased visualization.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER static(0), ledBlink(1), relayBlink(2)  

ioSignalConfigInput1Mode 1.3.6.1.4.1.3181.10.6.1.31.7.1.3
When this function is activated the external alarm input 1 is monitored. Note: alarm inputs are not available in all product versions.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), alarmWhenHigh(1), alarmWhenLow(2)  

ioSignalConfigInput1Name 1.3.6.1.4.1.3181.10.6.1.31.7.1.4
A customer specific name can be specified for input 1. This name will appear in the associated event messages.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

ioSignalConfigInput2Mode 1.3.6.1.4.1.3181.10.6.1.31.7.1.5
When this function is activated the external alarm input 2 is monitored. Note: alarm inputs are not available in all product versions.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), alarmWhenHigh(1), alarmWhenLow(2)  

ioSignalConfigInput2Name 1.3.6.1.4.1.3181.10.6.1.31.7.1.6
A customer specific name can be specified for input 2. This name will appear in the associated event messages.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

ioSignalConfigOutput1Trigger 1.3.6.1.4.1.3181.10.6.1.31.7.1.7
Defines on which condition the alarm relay 1 is activated. Note: alarm relays are not available in all product versions.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), whileRunning(1), redundancyFail(2), highTemp(3), off(4), on(5)  

ioSignalConfigOutput1Name 1.3.6.1.4.1.3181.10.6.1.31.7.1.8
A customer specific name can be specified for alarm output 1. This name will appear in the associated event messages.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

ioSignalConfigOutput2Trigger 1.3.6.1.4.1.3181.10.6.1.31.7.1.9
Defines on which condition the alarm relay 2 is activated. Note: alarm relays are not available in all product versions.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), whileRunning(1), redundancyFail(2), highTemp(3), off(4), on(5)  

ioSignalConfigOutput2Name 1.3.6.1.4.1.3181.10.6.1.31.7.1.10
A customer specific name can be specified for alarm output 2. This name will appear in the associated event messages.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

hardwarePowerSupply1Status 1.3.6.1.4.1.3181.10.6.1.31.100
Displays state of primary supply or only supply for single supply systems.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ok(0), overload(1), inputLow(2), fuseFail(3), notApplicable(4), unmanaged(5), notInstalled(6)  

hardwarePowerSupply2Status 1.3.6.1.4.1.3181.10.6.1.31.101
Displays state of secondary supply if available.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ok(0), overload(1), inputLow(2), fuseFail(3), notApplicable(4), unmanaged(5), notInstalled(6)  

hardwareRunningOnPoe 1.3.6.1.4.1.3181.10.6.1.31.102
When set the unit currently operates on the PD input via PoE.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER false(0), true(1)  

hardwareFanStatus 1.3.6.1.4.1.3181.10.6.1.31.103
Displays state of cooling fan. Indicates UNUSED in fanless devices.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unused(0), ok(1), degraded(2), fail(3), missing(4)  

hardwareSdCardStatus 1.3.6.1.4.1.3181.10.6.1.31.104
Current status of SD-card.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER empty(0), inserted(1), writeProtected(2), writing(3)  

hardwareNumOfPorts 1.3.6.1.4.1.3181.10.6.1.31.105
Total number of Ethernet ports this hardware offers.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..255  

hardwareMaskOfExistingPorts 1.3.6.1.4.1.3181.10.6.1.31.106
Set bit for each port that physically exisiting and could be in use.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

hardwareMaskOfSfpPorts 1.3.6.1.4.1.3181.10.6.1.31.107
Marks which ports support SFPs.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

hardwareMaskOfPoePorts 1.3.6.1.4.1.3181.10.6.1.31.108
Marks which ports support PoE output.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

moduleInfoTable 1.3.6.1.4.1.3181.10.6.1.31.109
This section indicates which modules are inserted in the optional extension slots.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ModuleInfoEntry

moduleInfoEntry 1.3.6.1.4.1.3181.10.6.1.31.109.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  ModuleInfoEntry  

moduleInfoIndex 1.3.6.1.4.1.3181.10.6.1.31.109.1.1
Automatically generated
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..3  

moduleInfoUnitType 1.3.6.1.4.1.3181.10.6.1.31.109.1.2
Identfies the general type of module.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notPresent(0), baseUnit(1), extension(2)  

moduleInfoArticleNumber 1.3.6.1.4.1.3181.10.6.1.31.109.1.3
The article number of the module in this slot.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

moduleInfoSerialNumber 1.3.6.1.4.1.3181.10.6.1.31.109.1.4
The serial number of the module in this slot.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

moduleInfoHardwareVersion 1.3.6.1.4.1.3181.10.6.1.31.109.1.5
This device hardware revision number.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

moduleInfoProjectNumber 1.3.6.1.4.1.3181.10.6.1.31.109.1.6
MICROSENS project number.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

moduleInfoOccupiedSlots 1.3.6.1.4.1.3181.10.6.1.31.109.1.7
Lists all slots contained in this module.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

moduleInfoDescription 1.3.6.1.4.1.3181.10.6.1.31.109.1.8
Feature summary of the module.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

slotInfoTable 1.3.6.1.4.1.3181.10.6.1.31.110
This section indicates which modules are inserted in the optional extension slots.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SlotInfoEntry

slotInfoEntry 1.3.6.1.4.1.3181.10.6.1.31.110.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SlotInfoEntry  

slotInfoIndex 1.3.6.1.4.1.3181.10.6.1.31.110.1.1
Automatically generated
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..7  

slotInfoBoardType 1.3.6.1.4.1.3181.10.6.1.31.110.1.2
General type of board function
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notPresent(0), undefined(1), power(2), cpu(3), port(4), io(5)  

slotInfoBoardId 1.3.6.1.4.1.3181.10.6.1.31.110.1.3
This identifies the board type for internal operation.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

slotInfoVersionBits 1.3.6.1.4.1.3181.10.6.1.31.110.1.4
Version bits from hardware or backplane.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..255  

portInfoTable 1.3.6.1.4.1.3181.10.6.1.31.111
Used to map physical to logical port ids.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PortInfoEntry

portInfoEntry 1.3.6.1.4.1.3181.10.6.1.31.111.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  PortInfoEntry  

portInfoPortIndex 1.3.6.1.4.1.3181.10.6.1.31.111.1.1
Automatically generated
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..24  

portInfoSystemSlot 1.3.6.1.4.1.3181.10.6.1.31.111.1.2
Describes on which system slot this port index is located.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..255  

portInfoSwitchPort 1.3.6.1.4.1.3181.10.6.1.31.111.1.3
Describes on which switch port this port index is located.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..255  

portInfoUserSlot 1.3.6.1.4.1.3181.10.6.1.31.111.1.4
Slot number as seen by customer.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..255  

portInfoUserPort 1.3.6.1.4.1.3181.10.6.1.31.111.1.5
Port number as seen by customer.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..255  

portInfoSnmpPort 1.3.6.1.4.1.3181.10.6.1.31.111.1.6
Slot and port representation as used in SNMP. Formula is Slot*100 + Port.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..65535  

portInfoSnmpInstance 1.3.6.1.4.1.3181.10.6.1.31.111.1.7
Port instance counting from 0 to number of ports
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..255  

portInfoHardwarePort 1.3.6.1.4.1.3181.10.6.1.31.111.1.8
Port number as used internally. Ports may not be in sequential order.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..255  

portInfoInterfaceType 1.3.6.1.4.1.3181.10.6.1.31.111.1.9
Identifies port as copper or optical. Also used for snmp ifType definition
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER copper(0), optical(1), dualMedia(2)  

portInfoProperties 1.3.6.1.4.1.3181.10.6.1.31.111.1.10
Describes which functions the port can support.
Status: current Access: read-only
OBJECT-TYPE    
  BITS internal(0), ms10Mb(1), ms100Mb(2), ms1000Mb(3), rj45(4), sfp(5), ms1x9(6), poe(7), poePlus(8), pd(9), dualMedia(10), linkPort(11), csfp(12)  

portLedsTable 1.3.6.1.4.1.3181.10.6.1.31.112
This section indicates the state of all port related LEDs.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PortLedsEntry

portLedsEntry 1.3.6.1.4.1.3181.10.6.1.31.112.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  PortLedsEntry  

portLedsPortIndex 1.3.6.1.4.1.3181.10.6.1.31.112.1.1
Automatically generated
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..31  

portLedsEthernetColor 1.3.6.1.4.1.3181.10.6.1.31.112.1.2
Ethernet Link LED.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), blue(1), green(2), red(3), orange(4), cyan(5), magenta(6), white(7), noLed(8)  

portLedsEthernetBlinking 1.3.6.1.4.1.3181.10.6.1.31.112.1.3
Ethernet Link LED.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER false(0), true(1)  

portLedsPoeColor 1.3.6.1.4.1.3181.10.6.1.31.112.1.4
Power over Ethernet LED. For optical ports this indicates signal detect status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), blue(1), green(2), red(3), orange(4), cyan(5), magenta(6), white(7), noLed(8)  

portLedsPoeBlinking 1.3.6.1.4.1.3181.10.6.1.31.112.1.5
Power over Ethernet LED. For optical ports this indicates signal detect status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER false(0), true(1)  

deviceLedsTable 1.3.6.1.4.1.3181.10.6.1.31.113
This section indicates the state of all LEDs which are not port related. Please note: Not every unit offers all LEDs.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DeviceLedsEntry

deviceLedsEntry 1.3.6.1.4.1.3181.10.6.1.31.113.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  DeviceLedsEntry  

deviceLedsIndex 1.3.6.1.4.1.3181.10.6.1.31.113.1.1
Automatically generated
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0  

deviceLedsSystem1Color 1.3.6.1.4.1.3181.10.6.1.31.113.1.2
This status corresponds to 'sys' LED on some devices.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), blue(1), green(2), red(3), orange(4), cyan(5), magenta(6), white(7), noLed(8)  

deviceLedsSystem1Blinking 1.3.6.1.4.1.3181.10.6.1.31.113.1.3
This status corresponds to 'sys' LED on some devices.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER false(0), true(1)  

deviceLedsSystem2Color 1.3.6.1.4.1.3181.10.6.1.31.113.1.4
Displays external management activity.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), blue(1), green(2), red(3), orange(4), cyan(5), magenta(6), white(7), noLed(8)  

deviceLedsSystem2Blinking 1.3.6.1.4.1.3181.10.6.1.31.113.1.5
Displays external management activity.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER false(0), true(1)  

deviceLedsPowerOn1Color 1.3.6.1.4.1.3181.10.6.1.31.113.1.6
This status corresponds to 'on' LED on some devices.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), blue(1), green(2), red(3), orange(4), cyan(5), magenta(6), white(7), noLed(8)  

deviceLedsPowerOn1Blinking 1.3.6.1.4.1.3181.10.6.1.31.113.1.7
This status corresponds to 'on' LED on some devices.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER false(0), true(1)  

deviceLedsPowerOn2Color 1.3.6.1.4.1.3181.10.6.1.31.113.1.8
Alternative power input LED.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), blue(1), green(2), red(3), orange(4), cyan(5), magenta(6), white(7), noLed(8)  

deviceLedsPowerOn2Blinking 1.3.6.1.4.1.3181.10.6.1.31.113.1.9
Alternative power input LED.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER false(0), true(1)  

deviceLedsRing1Color 1.3.6.1.4.1.3181.10.6.1.31.113.1.10
This LED is used when ring protection is enabled.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), blue(1), green(2), red(3), orange(4), cyan(5), magenta(6), white(7), noLed(8)  

deviceLedsRing1Blinking 1.3.6.1.4.1.3181.10.6.1.31.113.1.11
This LED is used when ring protection is enabled.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER false(0), true(1)  

deviceLedsRing2Color 1.3.6.1.4.1.3181.10.6.1.31.113.1.12
This LED is used when ring protection is enabled.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), blue(1), green(2), red(3), orange(4), cyan(5), magenta(6), white(7), noLed(8)  

deviceLedsRing2Blinking 1.3.6.1.4.1.3181.10.6.1.31.113.1.13
This LED is used when ring protection is enabled.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER false(0), true(1)  

deviceLedsSignalIn1Color 1.3.6.1.4.1.3181.10.6.1.31.113.1.14
Indicates status of alarm input 1.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), blue(1), green(2), red(3), orange(4), cyan(5), magenta(6), white(7), noLed(8)  

deviceLedsSignalIn1Blinking 1.3.6.1.4.1.3181.10.6.1.31.113.1.15
Indicates status of alarm input 1.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER false(0), true(1)  

deviceLedsSignalIn2Color 1.3.6.1.4.1.3181.10.6.1.31.113.1.16
Indicates status of alarm input 2.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), blue(1), green(2), red(3), orange(4), cyan(5), magenta(6), white(7), noLed(8)  

deviceLedsSignalIn2Blinking 1.3.6.1.4.1.3181.10.6.1.31.113.1.17
Indicates status of alarm input 2.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER false(0), true(1)  

deviceLedsSignalOut1Color 1.3.6.1.4.1.3181.10.6.1.31.113.1.18
Indicates status of alarm relay output 1.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), blue(1), green(2), red(3), orange(4), cyan(5), magenta(6), white(7), noLed(8)  

deviceLedsSignalOut1Blinking 1.3.6.1.4.1.3181.10.6.1.31.113.1.19
Indicates status of alarm relay output 1.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER false(0), true(1)  

deviceLedsSignalOut2Color 1.3.6.1.4.1.3181.10.6.1.31.113.1.20
Indicates status of alarm relay output 2.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), blue(1), green(2), red(3), orange(4), cyan(5), magenta(6), white(7), noLed(8)  

deviceLedsSignalOut2Blinking 1.3.6.1.4.1.3181.10.6.1.31.113.1.21
Indicates status of alarm relay output 2.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER false(0), true(1)  

cableTestStatusTable 1.3.6.1.4.1.3181.10.6.1.31.114
This table display the result of the last cable test. Values are only available for copper ports while a link is down and if the cable test function is enabled.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CableTestStatusEntry

cableTestStatusEntry 1.3.6.1.4.1.3181.10.6.1.31.114.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  CableTestStatusEntry  

cableTestStatusPortIndex 1.3.6.1.4.1.3181.10.6.1.31.114.1.1
Automatically generated
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..24  

cableTestStatusUpdateTimeStamp 1.3.6.1.4.1.3181.10.6.1.31.114.1.2
Indicates the time when this record was last updated.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

cableTestStatusPair0State 1.3.6.1.4.1.3181.10.6.1.31.114.1.3
Indicates line termination test results for wire pair 0 (Pins 1/2)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notAvailable(0), pairOk(1), pairOpen(2), samePairShort(3), crossPairShort(4)  

cableTestStatusPair0DistanceToFault 1.3.6.1.4.1.3181.10.6.1.31.114.1.4
Distance to fault on wire pair 0 in centimeters. Indicates 0 when no fault is detected or the function is unused.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..65535  

cableTestStatusPair1State 1.3.6.1.4.1.3181.10.6.1.31.114.1.5
Indicates line termination test results for wire pair 1 (Pins 3/6)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notAvailable(0), pairOk(1), pairOpen(2), samePairShort(3), crossPairShort(4)  

cableTestStatusPair1DistanceToFault 1.3.6.1.4.1.3181.10.6.1.31.114.1.6
Distance to fault on wire pair 1 in centimeters. Indicates 0 when no fault is detected or the function is unused.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..65535  

cableTestStatusPair2State 1.3.6.1.4.1.3181.10.6.1.31.114.1.7
Indicates line termination test results for wire pair 2 (Pins 4/5)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notAvailable(0), pairOk(1), pairOpen(2), samePairShort(3), crossPairShort(4)  

cableTestStatusPair2DistanceToFault 1.3.6.1.4.1.3181.10.6.1.31.114.1.8
Distance to fault on wire pair 2 in centimeters. Indicates 0 when no fault is detected or the function is unused.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..65535  

cableTestStatusPair3State 1.3.6.1.4.1.3181.10.6.1.31.114.1.9
Indicates line termination test results for wire pair 3 (Pins 7/8)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notAvailable(0), pairOk(1), pairOpen(2), samePairShort(3), crossPairShort(4)  

cableTestStatusPair3DistanceToFault 1.3.6.1.4.1.3181.10.6.1.31.114.1.10
Distance to fault on wire pair 3 in centimeters. Indicates 0 when no fault is detected or the function is unused.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..65535  

cableTestStatusCableStatus 1.3.6.1.4.1.3181.10.6.1.31.114.1.11
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notAvailable(0), pluggedIn(1), open(2)  

ioSignalStatusTable 1.3.6.1.4.1.3181.10.6.1.31.115
This section is only used for devices which offer external signal inputs and outputs.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IoSignalStatusEntry

ioSignalStatusEntry 1.3.6.1.4.1.3181.10.6.1.31.115.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  IoSignalStatusEntry  

ioSignalStatusIndex 1.3.6.1.4.1.3181.10.6.1.31.115.1.1
Automatically generated
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0  

ioSignalStatusInput1AlarmActive 1.3.6.1.4.1.3181.10.6.1.31.115.1.2
Indicates true when the input 1 is logically active.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER false(0), true(1)  

ioSignalStatusInput2AlarmActive 1.3.6.1.4.1.3181.10.6.1.31.115.1.3
Indicates true when the input 2 is logically active.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER false(0), true(1)  

ioSignalStatusOutput1RelayActive 1.3.6.1.4.1.3181.10.6.1.31.115.1.4
Indicates true when the output 1 relay is activated.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER false(0), true(1)  

ioSignalStatusOutput2RelayActive 1.3.6.1.4.1.3181.10.6.1.31.115.1.5
Indicates true when the output 2 relay is activated.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER false(0), true(1)  

tcamStatusTable 1.3.6.1.4.1.3181.10.6.1.31.116
This section is only used for devices which offer external signal inputs and outputs.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TcamStatusEntry

tcamStatusEntry 1.3.6.1.4.1.3181.10.6.1.31.116.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  TcamStatusEntry  

tcamStatusIndex 1.3.6.1.4.1.3181.10.6.1.31.116.1.1
Automatically generated
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..255  

tcamStatusControlFile 1.3.6.1.4.1.3181.10.6.1.31.116.1.2
Reflects the name of the control file associated with this tcam entry.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

tcamStatusDescription 1.3.6.1.4.1.3181.10.6.1.31.116.1.3
Descriptive text what explains what this tcam entry will do.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString