GC-MIB

File: GC-MIB.mib (15713 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC RBT-MIB

Imported symbols

OBJECT-TYPE MODULE-IDENTITY NOTIFICATION-TYPE
Unsigned32 TimeTicks IpAddress
Counter64 DateAndTime products

Defined Types

ProcEntry  
SEQUENCE    
  procIndex Unsigned32
  procName OCTET STRING
  procStatus OCTET STRING
  procNumFailures Unsigned32

CPUIndivUtilEntry  
SEQUENCE    
  cpuIndivIndex Unsigned32
  cpuIndivId Unsigned32
  cpuIndivIdleTime Unsigned32
  cpuIndivSystemTime Unsigned32
  cpuIndivUserTime Unsigned32

Defined Values

gc 1.3.6.1.4.1.17163.1.100
Riverbed Technology SteelFusion Core MIB
MODULE-IDENTITY    

system 1.3.6.1.4.1.17163.1.100.1
OBJECT IDENTIFIER    

status 1.3.6.1.4.1.17163.1.100.2
OBJECT IDENTIFIER    

config 1.3.6.1.4.1.17163.1.100.3
OBJECT IDENTIFIER    

alarms 1.3.6.1.4.1.17163.1.100.4
OBJECT IDENTIFIER    

statistics 1.3.6.1.4.1.17163.1.100.5
OBJECT IDENTIFIER    

model 1.3.6.1.4.1.17163.1.100.1.1
Appliance model
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

serialNumber 1.3.6.1.4.1.17163.1.100.1.2
Appliance serial number
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

systemVersion 1.3.6.1.4.1.17163.1.100.1.3
System software version string
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

systemClock 1.3.6.1.4.1.17163.1.100.2.1
System clock time
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

health 1.3.6.1.4.1.17163.1.100.2.2
Current health
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

systemHealth 1.3.6.1.4.1.17163.1.100.2.3
Current health of the system. This variable is identical to health except that it is of integer datatype
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER healthy(10000), degraded(30000), critical(50000)  

systemTemperature 1.3.6.1.4.1.17163.1.100.2.4
The temperature of the system (C)
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

procTable 1.3.6.1.4.1.17163.1.100.2.11
List of managed processes
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ProcEntry

procEntry 1.3.6.1.4.1.17163.1.100.2.11.1
Entry for one process
Status: current Access: not-accessible
OBJECT-TYPE    
  ProcEntry  

procIndex 1.3.6.1.4.1.17163.1.100.2.11.1.1
Synthetic numeric unique ID of process
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

procName 1.3.6.1.4.1.17163.1.100.2.11.1.2
Unique name of process
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

procStatus 1.3.6.1.4.1.17163.1.100.2.11.1.3
Current state of process
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

procNumFailures 1.3.6.1.4.1.17163.1.100.2.11.1.4
Number of times process has crashed or exited unexpectedly
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

activeConfig 1.3.6.1.4.1.17163.1.100.3.1
Current active configuration
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

alarmsPrefix 1.3.6.1.4.1.17163.1.100.4.0
OBJECT IDENTIFIER    

procCrash 1.3.6.1.4.1.17163.1.100.4.0.1
A procCrash trap signifies that a process managed by PM has crashed and left a core file. The variable sent with the notification indicates which process crashed.
Status: current Access: read-only
NOTIFICATION-TYPE    

procExit 1.3.6.1.4.1.17163.1.100.4.0.2
A procExit trap signifies that a process managed by PM has exited unexpectedly, but not left a core file. The variable sent with the notification indicates which process exited.
Status: current Access: read-only
NOTIFICATION-TYPE    

configChange 1.3.6.1.4.1.17163.1.100.4.0.3
A change has been made to the system's configuration
Status: current Access: read-only
NOTIFICATION-TYPE    

cpuUtil 1.3.6.1.4.1.17163.1.100.4.0.4
The average CPU utilization in the past minute has gone above the acceptable threshold
Status: current Access: read-only
NOTIFICATION-TYPE    

pagingActivity 1.3.6.1.4.1.17163.1.100.4.0.5
The system has been paging excessively (thrashing)
Status: current Access: read-only
NOTIFICATION-TYPE    

linkError 1.3.6.1.4.1.17163.1.100.4.0.6
An interface on the appliance has lost its link
Status: current Access: read-only
NOTIFICATION-TYPE    

powerSupplyError 1.3.6.1.4.1.17163.1.100.4.0.7
A power supply on the appliance has failed
Status: current Access: read-only
NOTIFICATION-TYPE    

fanError 1.3.6.1.4.1.17163.1.100.4.0.8
A fan has failed on this appliance
Status: current Access: read-only
NOTIFICATION-TYPE    

memoryError 1.3.6.1.4.1.17163.1.100.4.0.9
A memory error has been detected on the appliance
Status: current Access: read-only
NOTIFICATION-TYPE    

ipmi 1.3.6.1.4.1.17163.1.100.4.0.10
An IPMI event has been detected on the appliance. Please check the details in the alarm report on the web UI
Status: current Access: read-only
NOTIFICATION-TYPE    

localFSFull 1.3.6.1.4.1.17163.1.100.4.0.11
The appliance local filesystem is full.
Status: current Access: read-only
NOTIFICATION-TYPE    

temperatureCritical 1.3.6.1.4.1.17163.1.100.4.0.12
The system temperature has reached a critical stage
Status: current Access: read-only
NOTIFICATION-TYPE    

temperatureWarning 1.3.6.1.4.1.17163.1.100.4.0.13
The system temperature has exceeded the threshold
Status: current Access: read-only
NOTIFICATION-TYPE    

scheduledJobError 1.3.6.1.4.1.17163.1.100.4.0.14
A scheduled job has failed during execution
Status: current Access: read-only
NOTIFICATION-TYPE    

confModeEnter 1.3.6.1.4.1.17163.1.100.4.0.15
A user has entered configuration mode
Status: current Access: read-only
NOTIFICATION-TYPE    

confModeExit 1.3.6.1.4.1.17163.1.100.4.0.16
A user has exited configuration mode
Status: current Access: read-only
NOTIFICATION-TYPE    

secureVaultLocked 1.3.6.1.4.1.17163.1.100.4.0.17
Secure vault is locked. The secure datastore cannot be used.
Status: current Access: read-only
NOTIFICATION-TYPE    

procRestart 1.3.6.1.4.1.17163.1.100.4.0.18
A procRestart trap signifies that a process managed by PM has restarted. The variable sent with the notification indicates which process restarted.
Status: current Access: read-only
NOTIFICATION-TYPE    

testTrap 1.3.6.1.4.1.17163.1.100.4.0.19
This is a test trap.
Status: current Access: read-only
NOTIFICATION-TYPE    

edgeError 1.3.6.1.4.1.17163.1.100.4.0.10500
Edge module encountered error.
Status: current Access: read-only
NOTIFICATION-TYPE    

highAvailabilityError 1.3.6.1.4.1.17163.1.100.4.0.10501
High Availability module encountered error.
Status: current Access: read-only
NOTIFICATION-TYPE    

lunError 1.3.6.1.4.1.17163.1.100.4.0.10502
Lun module encountered error.
Status: current Access: read-only
NOTIFICATION-TYPE    

iscsiError 1.3.6.1.4.1.17163.1.100.4.0.10503
iSCSI module encountered error.
Status: current Access: read-only
NOTIFICATION-TYPE    

snapshotError 1.3.6.1.4.1.17163.1.100.4.0.10505
Snapshot module encountered error.
Status: current Access: read-only
NOTIFICATION-TYPE    

applianceUnlicensedError 1.3.6.1.4.1.17163.1.100.4.0.10506
Appliance license expired/invalid.
Status: current Access: read-only
NOTIFICATION-TYPE    

modelUnlicensedError 1.3.6.1.4.1.17163.1.100.4.0.10507
Model license expired/invalid.
Status: current Access: read-only
NOTIFICATION-TYPE    

blkdiskError 1.3.6.1.4.1.17163.1.100.4.0.10508
Block-disk module encountered error.
Status: current Access: read-only
NOTIFICATION-TYPE    

backupIntegrationError 1.3.6.1.4.1.17163.1.100.4.0.10509
Backup-Integration module encountered error.
Status: current Access: read-only
NOTIFICATION-TYPE    

otherHardwareError 1.3.6.1.4.1.17163.1.100.4.0.10510
Hardware Error detected.
Status: current Access: read-only
NOTIFICATION-TYPE    

cpuUtilClear 1.3.6.1.4.1.17163.1.100.4.0.1004
The average CPU utilization has fallen back within the acceptable threshold
Status: current Access: read-only
NOTIFICATION-TYPE    

pagingActivityClear 1.3.6.1.4.1.17163.1.100.4.0.1005
The system has stopped paging excessively (thrashing)
Status: current Access: read-only
NOTIFICATION-TYPE    

linkErrorClear 1.3.6.1.4.1.17163.1.100.4.0.1006
An interface on the appliance has regained its link
Status: current Access: read-only
NOTIFICATION-TYPE    

powerSupplyErrorClear 1.3.6.1.4.1.17163.1.100.4.0.1007
All power supplies are now functioning normally
Status: current Access: read-only
NOTIFICATION-TYPE    

fanErrorClear 1.3.6.1.4.1.17163.1.100.4.0.1008
All system fans are now functioning normally
Status: current Access: read-only
NOTIFICATION-TYPE    

memoryErrorClear 1.3.6.1.4.1.17163.1.100.4.0.1009
A memory error has been rectified on the appliance
Status: current Access: read-only
NOTIFICATION-TYPE    

ipmiClear 1.3.6.1.4.1.17163.1.100.4.0.1010
An IPMI event has been rectified on the appliance
Status: current Access: read-only
NOTIFICATION-TYPE    

localFSFullClear 1.3.6.1.4.1.17163.1.100.4.0.1011
The appliance local filesystem usage is below threshold.
Status: current Access: read-only
NOTIFICATION-TYPE    

temperatureNonCritical 1.3.6.1.4.1.17163.1.100.4.0.1012
The system temperature is no longer in a critical stage
Status: current Access: read-only
NOTIFICATION-TYPE    

temperatureNormal 1.3.6.1.4.1.17163.1.100.4.0.1013
The system temperature is back within the threshold
Status: current Access: read-only
NOTIFICATION-TYPE    

secureVaultUnlocked 1.3.6.1.4.1.17163.1.100.4.0.1017
Secure vault is unlocked. The secure data store can be used now.
Status: current Access: read-only
NOTIFICATION-TYPE    

edgeClear 1.3.6.1.4.1.17163.1.100.4.0.11500
Edge module error cleared.
Status: current Access: read-only
NOTIFICATION-TYPE    

highAvailabilityClear 1.3.6.1.4.1.17163.1.100.4.0.11501
High Availability module error cleared.
Status: current Access: read-only
NOTIFICATION-TYPE    

lunClear 1.3.6.1.4.1.17163.1.100.4.0.11502
Lun module error cleared.
Status: current Access: read-only
NOTIFICATION-TYPE    

iscsiClear 1.3.6.1.4.1.17163.1.100.4.0.11503
iSCSI module error cleared.
Status: current Access: read-only
NOTIFICATION-TYPE    

snapshotClear 1.3.6.1.4.1.17163.1.100.4.0.11505
Snapshot module error cleared.
Status: current Access: read-only
NOTIFICATION-TYPE    

applianceUnlicensedClear 1.3.6.1.4.1.17163.1.100.4.0.11506
Appliance license active.
Status: current Access: read-only
NOTIFICATION-TYPE    

modelUnlicensedClear 1.3.6.1.4.1.17163.1.100.4.0.11507
Model license active.
Status: current Access: read-only
NOTIFICATION-TYPE    

blkdiskClear 1.3.6.1.4.1.17163.1.100.4.0.11508
Block-disk module error cleared.
Status: current Access: read-only
NOTIFICATION-TYPE    

backupIntegrationClear 1.3.6.1.4.1.17163.1.100.4.0.11509
Backup-Integration module error cleared.
Status: current Access: read-only
NOTIFICATION-TYPE    

otherHardwareClear 1.3.6.1.4.1.17163.1.100.4.0.11510
Hardware error cleared.
Status: current Access: read-only
NOTIFICATION-TYPE    

cpuLoad 1.3.6.1.4.1.17163.1.100.5.1
OBJECT IDENTIFIER    

cpuLoad1 1.3.6.1.4.1.17163.1.100.5.1.1
One-minute CPU load in hundreths
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

cpuLoad5 1.3.6.1.4.1.17163.1.100.5.1.2
One-minute CPU load in hundreths
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

cpuLoad15 1.3.6.1.4.1.17163.1.100.5.1.3
Fifteen-minute CPU load in hundreths
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

cpuUtil1 1.3.6.1.4.1.17163.1.100.5.1.4
Percentage CPU utilization, aggregated across all CPUs, rolling average over the past minute
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

cpuIndivUtilTable 1.3.6.1.4.1.17163.1.100.5.1.5
Details about the individual CPU utilization
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CPUIndivUtilEntry

cpuIndivUtilEntry 1.3.6.1.4.1.17163.1.100.5.1.5.1
Entry for one cpu
Status: current Access: not-accessible
OBJECT-TYPE    
  CPUIndivUtilEntry  

cpuIndivIndex 1.3.6.1.4.1.17163.1.100.5.1.5.1.1
A synthetic number numbering the cpus
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

cpuIndivId 1.3.6.1.4.1.17163.1.100.5.1.5.1.2
Name of the cpu, also serves as the Index for the table
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

cpuIndivIdleTime 1.3.6.1.4.1.17163.1.100.5.1.5.1.3
Idle time for this CPU
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

cpuIndivSystemTime 1.3.6.1.4.1.17163.1.100.5.1.5.1.4
System time for this CPU
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

cpuIndivUserTime 1.3.6.1.4.1.17163.1.100.5.1.5.1.5
User time for this CPU
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32