GDCUAS7022-MIB

File: GDCUAS7022-MIB.mib (69683 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB
GDCMACRO-MIB

Imported symbols

enterprises OBJECT-TYPE DisplayString
SCinstance

Defined Types

Uas7022VersionEntry  
SEQUENCE    
  uas7022VersionIndex SCinstance
  uas7022ActiveFirmwareRev DisplayString
  uas7022StoredFirmwareRev DisplayString
  uas7022StoredFirmwareStatus INTEGER
  uas7022SwitchActiveFirmware INTEGER
  uas7022DownloadingMode INTEGER

Uas7022MaintenanceEntry  
SEQUENCE    
  uas7022MaintenanceLineIndex SCinstance
  uas7022SoftReset INTEGER
  uas7022SysUpTime INTEGER
  uas7022DefaultInit INTEGER
  uas7022LedStatus OCTET STRING
  uas7022AlarmStatus OCTET STRING
  uas7022NearEndResetStats INTEGER
  uas7022FarEndResetStats INTEGER
  uas7022NearEndStatLastInit INTEGER
  uas7022FarEndStatLastInit INTEGER
  uas7022NearEndValidIntervals INTEGER
  uas7022FarEndValidIntervals INTEGER
  uas7022NIUaCircuitID DisplayString
  uas7022SystemTimingGenStatus INTEGER
  uas7022NIUbCircuitID DisplayString

Uas7022ConfigEntry  
SEQUENCE    
  uas7022ConfigIndex SCinstance
  uas7022RcvrRange INTEGER
  uas7022Framing INTEGER
  uas7022SysTimingGen INTEGER
  uas7022Highway INTEGER
  uas7022TransmitClockSource INTEGER
  uas7022FallbackClockSource INTEGER
  uas7022InterfaceType INTEGER
  uas7022FDLMode INTEGER
  uas7022TimeSlot16Content INTEGER
  uas7022Impedance INTEGER

Uas7022DiagEntry  
SEQUENCE    
  uas7022DiagIndex SCinstance
  uas7022DiagConfig INTEGER
  uas7022TestLimit INTEGER
  uas7022TestExecutionStatus INTEGER
  uas7022TestExceptions INTEGER

Uas7022NearEndCurrent15MinEntry  
SEQUENCE    
  uas7022NearEndCurrent15MinIndex SCinstance
  uas7022NearEndCurrent15MinStat OCTET STRING

Uas7022NearEndIntervalEntry  
SEQUENCE    
  uas7022NearEndIntervalIndex SCinstance
  uas7022NearEndIntervalNumber INTEGER
  uas7022NearEndIntervalStat OCTET STRING

Uas7022NearEndCurrent24HrEntry  
SEQUENCE    
  uas7022NearEndCurrent24HrIndex SCinstance
  uas7022NearEndCurrent24HrStat OCTET STRING

Uas7022NearEndRecent24HrEntry  
SEQUENCE    
  uas7022NearEndRecent24HrIndex SCinstance
  uas7022NearEndRecent24HrStat OCTET STRING

Uas7022NearEndUnavailableTimeRegEntry  
SEQUENCE    
  uas7022NearEndUnavailableTimeRegIndex SCinstance
  uas7022NearEndUnavailableTimeRegNumber INTEGER
  uas7022NearEndUnavailableTimeRegStart INTEGER
  uas7022NearEndUnavailableTimeRegStop INTEGER

Uas7022FarEndCurrent15MinEntry  
SEQUENCE    
  uas7022FarEndCurrent15MinIndex SCinstance
  uas7022FarEndCurrent15MinStat OCTET STRING

Uas7022FarEndIntervalEntry  
SEQUENCE    
  uas7022FarEndIntervalIndex SCinstance
  uas7022FarEndIntervalNumber INTEGER
  uas7022FarEndIntervalStat OCTET STRING

Uas7022FarEndCurrent24HrEntry  
SEQUENCE    
  uas7022FarEndCurrent24HrIndex SCinstance
  uas7022FarEndCurrent24HrStat OCTET STRING

Uas7022FarEndRecent24HrEntry  
SEQUENCE    
  uas7022FarEndRecent24HrIndex SCinstance
  uas7022FarEndRecent24HrStat OCTET STRING

Uas7022FarEndUnavailableTimeRegEntry  
SEQUENCE    
  uas7022FarEndUnavailableTimeRegIndex SCinstance
  uas7022FarEndUnavailableTimeRegNumber INTEGER
  uas7022FarEndUnavailableTimeRegStart INTEGER
  uas7022FarEndUnavailableTimeRegStop INTEGER

Uas7022NearEndAlarmConfigEntry  
SEQUENCE    
  uas7022NearEndAlarmConfigIndex SCinstance
  uas7022NearEndAlarmConfigIdentifier OBJECT IDENTIFIER
  uas7022NearEndAlarmCountWindow INTEGER
  uas7022NearEndAlarmCountThreshold INTEGER

Uas7022FarEndAlarmConfigEntry  
SEQUENCE    
  uas7022FarEndAlarmConfigIndex SCinstance
  uas7022FarEndAlarmConfigIdentifier OBJECT IDENTIFIER
  uas7022FarEndAlarmCountWindow INTEGER
  uas7022FarEndAlarmCountThreshold INTEGER

Uas7022LocalAlarmConfigEntry  
SEQUENCE    
  uas7022LocalAlarmConfigIndex SCinstance
  uas7022UASNE INTEGER
  uas7022SESNE INTEGER
  uas7022BBENE INTEGER
  uas7022ESNE INTEGER
  uas7022UASFE INTEGER
  uas7022SESFE INTEGER
  uas7022BBEFE INTEGER
  uas7022ESFE INTEGER
  uas7022LOS INTEGER
  uas7022LOF INTEGER
  uas7022AIS INTEGER
  uas7022TmgLoss INTEGER
  uas7022LCVs INTEGER
  uas7022NtwkRAI INTEGER

Defined Values

gdc 1.3.6.1.4.1.498
OBJECT IDENTIFIER    

dsx1 1.3.6.1.4.1.498.6
OBJECT IDENTIFIER    

uas7022 1.3.6.1.4.1.498.6.13
OBJECT IDENTIFIER    

uas7022Version 1.3.6.1.4.1.498.6.13.1
OBJECT IDENTIFIER    

uas7022Maintenance 1.3.6.1.4.1.498.6.13.2
OBJECT IDENTIFIER    

uas7022Configuration 1.3.6.1.4.1.498.6.13.3
OBJECT IDENTIFIER    

uas7022Diagnostics 1.3.6.1.4.1.498.6.13.4
OBJECT IDENTIFIER    

uas7022Performance 1.3.6.1.4.1.498.6.13.5
OBJECT IDENTIFIER    

uas7022Alarms 1.3.6.1.4.1.498.6.13.6
OBJECT IDENTIFIER    

uas7022AlarmConfig 1.3.6.1.4.1.498.6.13.7
OBJECT IDENTIFIER    

uas7022MIBversion 1.3.6.1.4.1.498.6.13.1.1
Identifies the version of the MIB. The format of the version is x.yzT, where 'x' identifies the major revision number, 'y' identifies the minor revision number, 'z' identifies the typographical revision, and T identifies the test revision. Acceptable values for the individual revision components are as follows: x: 1 - 9 y: 0 - 9 z: 0 - 9 T: A - Z Upon formal release, no designation for the test revision will be present.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(5)  

uas7022VersionTable 1.3.6.1.4.1.498.6.13.1.2
The 7022 version table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Uas7022VersionEntry

uas7022VersionEntry 1.3.6.1.4.1.498.6.13.1.2.1
An entry in the GDC uas7022 Version Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Uas7022VersionEntry  

uas7022VersionIndex 1.3.6.1.4.1.498.6.13.1.2.1.1
Integer value which uniquely identifies the UAS7022 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (00)
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

uas7022ActiveFirmwareRev 1.3.6.1.4.1.498.6.13.1.2.1.2
The version number of the firmware currently executing. The format is MM.NN.BB where: MM: Major Revision (0-99) NN: Minor Revision (0-99) BB: Bug Fix Revision (0-99) Valid [i]nterface = 0
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(8)  

uas7022StoredFirmwareRev 1.3.6.1.4.1.498.6.13.1.2.1.3
The version number of the firmware stored (in a compressed format) but not currently executing. MM: Major Revision (0-99) NN: Minor Revision (0-99) BB: Bug Fix Revision (0-99) Valid [i]nterface = 0
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(8)  

uas7022StoredFirmwareStatus 1.3.6.1.4.1.498.6.13.1.2.1.4
This object represents the state of the Non-Active or Stored firmware: statBlank(1) Factory Default statDownLoading(2) In process of downloading firmware statOK(3) Zipped version checksum succesful (OK to switch) (can set uas7022SwitchActiveFirmware to switchActive(2)) statCheckSumBad(4) Failed checksum after download statUnZipping(5) In process of uncompressing into active area statBadUnZip(6) Failed last uncompress statDownloadAborted(7) Download aborted by user Valid [i]nterface = 0
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER statBlank(1), statDownLoading(2), statOK(3), statCheckSumBad(4), statUnZipping(5), statBadUnZip(6), statDownloadAborted(7)  

uas7022SwitchActiveFirmware 1.3.6.1.4.1.498.6.13.1.2.1.5
This object is used to switch the active executing firmware from the version in uas7022ActiveFirmwareRev to the version in uas7022StoredFirmwareRev. When a switchActive(2) is set (write only) the element will: 1) reboot 2) uncompress stored code into active area 3) perform checksum on active area 4) Set uas7022StoredStatus object to indicate results 5) If succesfull: update uas7022ActiveFirmwareRev and uas7022StoredFirmwareRev and begin executing If failed: replace active area with previous revision The switchNorm(1) enumeration will always be read. Setting switchActive(2) when the uas7022StoredFirmwareStatus is not statOK(3) will result in an error. Valid [i]nterface = 0
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER switchNorm(1), switchActive(2)  

uas7022DownloadingMode 1.3.6.1.4.1.498.6.13.1.2.1.6
This object is used to configure the download mode: disableAll(1) Prevents any firmware downloading to UAS7022 enableAndWait(2) Allows downloading zipped code to be stored only! enableAndSwitch(3) Allows downloading and then unzips and begins executing the new code Valid [i]nterface = 0
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disableAll(1), enableAndWait(2), enableAndSwitch(3)  

uas7022MaintenanceTable 1.3.6.1.4.1.498.6.13.2.1
The uas7022 maintenance table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Uas7022MaintenanceEntry

uas7022MaintenanceEntry 1.3.6.1.4.1.498.6.13.2.1.1
An entry in the 7022 Maintenance Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Uas7022MaintenanceEntry  

uas7022MaintenanceLineIndex 1.3.6.1.4.1.498.6.13.2.1.1.1
Integer value which uniquely identifies the UAS7022 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (00-02)
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

uas7022SoftReset 1.3.6.1.4.1.498.6.13.2.1.1.2
Supports the action of soft resetting the unit. When this object is set to reset(2), then the unit performs a soft reset, whose meaning is specific to the type of unit being managed. The value of norm(1) will be returned when the reset is complete. The value of norm(1) can not be set by management. Valid [i]nterface = 0
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER norm(1), reset(2)  

uas7022SysUpTime 1.3.6.1.4.1.498.6.13.2.1.1.3
This variable is used to report the elapsed system tick time for conversion to real time at the controller and is not related to the sysUpTime referenced in MIB-II. Upon power-up of the unit, the elapsed time is cleared. The elapsed time counter rolls over upon reaching the maximum count. Valid [i]nterface = 0
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

uas7022DefaultInit 1.3.6.1.4.1.498.6.13.2.1.1.4
This is used to allow the NonVolatile Configuration to be set to a factory default state. When this value is set to factoryDefault(1) the unit will perform a reset to make the default configuration take affect. The value of normal(2) will be returned when the initialization is complete. The value of normal(2) can not be set by management. Valid [i]nterface = 0
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), factoryDefault(2)  

uas7022LedStatus 1.3.6.1.4.1.498.6.13.2.1.1.5
Returns a bitwise snapshot of the front panel LED state. Octet 1 bit 7 - not used bit 6 - future use bit 5 - INSV bit 4 - RSP bit 3 - TMG bit 2 - TM bit 1 - ALM bit 0 - future use Octet 2 bit 7 - not used bit 6 - future use bit 5 - NIUA AIS bit 4 - NIUA LCV bit 3 - NIUA LOS bit 2 - NIUA OOF bit 1 - future use bit 0 - future use Octet 3 bit 7 - not used bit 6 - ST- future use bit 5 - NIUB AIS bit 4 - NIUB LCV bit 3 - NIUB LOS bit 2 - NIUB OOF bit 1 - future use bit 0 - future use Valid [i]nterface = 0
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(3)  

uas7022AlarmStatus 1.3.6.1.4.1.498.6.13.2.1.1.6
Returns a bit-wise Status of alarms Octet 1 bit 7 - not used bit 6 - NIUA_LOS bit 5 - NIUA_LOF bit 4 - NIUA_AIS bit 3 - NIUA_LCV bit 2 - NIUA TIMING LOSS bit 1 - NIUA_NE_ES bit 0 - NIUA_NE_BBE Octet 2 bit 7 - not used bit 6 - NIUA_NE_SES bit 5 - NIUA_NE_UAS bit 4 - NIUA_FE_ES bit 3 - NIUA_FE_BBE bit 2 - NIUA_FE_SES bit 1 - NIUA_FE_UAS bit 0 - NIUA_RAI Octet 3 bit 7 - not used bit 6 - NIUB_LOS bit 5 - NIUB_LOF bit 4 - NIUB_AIS bit 3 - NIUB_LCV bit 2 - NIUB TIMING LOSS bit 1 - NIUB_NE_ES bit 0 - NIUB_NE_BBE Octet 4 bit 7 - not used bit 6 - NIUB_NE_SES bit 5 - NIUB_NE_UAS bit 4 - NIUB_FE_ES bit 3 - NIUB_FE_BBE bit 2 - NIUB_FE_SES bit 1 - NIUB_FE_UAS bit 0 - NIUB_RAI Octet 5 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - future use bit 1 - future use bit 0 - Power-up Alarm Valid [i]nterface = 0
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(5)  

uas7022NearEndResetStats 1.3.6.1.4.1.498.6.13.2.1.1.7
Supports the action of soft resetting the uas7022NearEndValidIntervals object. When this object is set to reset(2), then the unit will reset the uas7022NearEndValidIntervals object to zero. The value of norm(1) can not be set by management. Valid [i]nterface = 1-2
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER norm(1), reset(2)  

uas7022FarEndResetStats 1.3.6.1.4.1.498.6.13.2.1.1.8
Supports the action of soft resetting the uas7022FarEndValidIntervals object. When this object is set to reset(2), then the unit will reset the uas7022FarEndValidIntervals object to zero. The value of norm(1) can not be set by management. Valid [i]nterface = 1-2
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER norm(1), reset(2)  

uas7022NearEndStatLastInit 1.3.6.1.4.1.498.6.13.2.1.1.9
Number of seconds from midnight Dec 31, 1969 up until uas7022NearEndValidIntervals was last initialized to zero Valid [i]nterface = 1-2
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

uas7022FarEndStatLastInit 1.3.6.1.4.1.498.6.13.2.1.1.10
Number of seconds from midnight Dec 31, 1969 up until uas7022FarEndValidIntervals was last initialized to zero Valid [i]nterface = 1-2
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

uas7022NearEndValidIntervals 1.3.6.1.4.1.498.6.13.2.1.1.11
The number of previous intervals for which valid data was collected. The value will be 16 unless the interface was brought on-line within the last 4 hours, in which case the value will be the number of complete 15 minute intervals the since interface has been online. Valid [i]nterface = 1-2
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

uas7022FarEndValidIntervals 1.3.6.1.4.1.498.6.13.2.1.1.12
The number of previous intervals for which valid data was collected. The value will be 16 unless the interface was brought on-line within the last 4 hours, in which case the value will be the number of complete 15 minute intervals the since interface has been online. Valid [i]nterface = 1-2
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

uas7022NIUaCircuitID 1.3.6.1.4.1.498.6.13.2.1.1.13
This variable is used for general purpose storage. Valid [i]nterface = 1
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(16)  

uas7022SystemTimingGenStatus 1.3.6.1.4.1.498.6.13.2.1.1.14
Indicates if the units configured for primary or secondary system clock are actually supplying clock and if it is the 8hkz, 4mhz, or both. Valid [i]nterface = 1-2
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), clk8khz(2), clk4mhz(3), clk8khzand4mhz(4)  

uas7022NIUbCircuitID 1.3.6.1.4.1.498.6.13.2.1.1.15
This variable is used for general purpose storage. Valid [i]nterface = 2
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(16)  

uas7022ConfigTable 1.3.6.1.4.1.498.6.13.3.1
The Configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Uas7022ConfigEntry

uas7022ConfigEntry 1.3.6.1.4.1.498.6.13.3.1.1
The Configuration table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Uas7022ConfigEntry  

uas7022ConfigIndex 1.3.6.1.4.1.498.6.13.3.1.1.1
Integer value which uniquely identifies the UAS7022 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (01-02)
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

uas7022RcvrRange 1.3.6.1.4.1.498.6.13.3.1.1.2
Sets the receiver range to short (6dB) or long (36dB) Valid [i]nterface = 1-2
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER short(1), long(2)  

uas7022Framing 1.3.6.1.4.1.498.6.13.3.1.1.3
Set the framing for the interface. Abbreviations are as follows: CCS - common-channel signaling CAS - channel-associated signaling Default is CAS If uas7022Framing is CAS then TimeSlot 16 contains idle code. If uas7022Framing is CCS then TimeSlot 16 contains either marks or user data. See uas7022TimeSlot16Content. Valid [i]nterface = 1-2
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER cCSwithoutCRC4(1), cASwithoutCRC4(2), cCSwithCRC4(3), cASwithCRC4(4)  

uas7022SysTimingGen 1.3.6.1.4.1.498.6.13.3.1.1.4
Selects if the unit provides system timing. none(1) - does not provide Timing Generator primary(2) - unit is primary Timing Generator for the shelf. secondary(3) - unit is secondary Timing Generator for the shelf. Only 1 unit in the shelf can the primary or secondary timing generator. All other must be none. Valid [i]nterface = 1-2
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), primary(2), secondary(3)  

uas7022Highway 1.3.6.1.4.1.498.6.13.3.1.1.5
Defines the highway allocation. No two NIU interfaces in the shelf can be assigned to the same highway. Valid [i]nterface = 1-2
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notAssigned(1), highway1(2), highway2(3), highway3(4), highway4(5), highway5(6), highway6(7), highway7(8), highway8(9)  

uas7022TransmitClockSource 1.3.6.1.4.1.498.6.13.3.1.1.6
Sets the transmit clock source. Valid [i]nterface = 1-2
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER system(1), recovered(2), internal(3)  

uas7022FallbackClockSource 1.3.6.1.4.1.498.6.13.3.1.1.7
Identifies the fallback transmit clock source. Valid [i]nterface = 1-2
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER system(1), recovered(2), internal(3)  

uas7022InterfaceType 1.3.6.1.4.1.498.6.13.3.1.1.8
Sets the interface type. Valid [i]nterface = 1-2
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER network(1), unassigned(2)  

uas7022FDLMode 1.3.6.1.4.1.498.6.13.3.1.1.9
Sets the interface type. Valid [i]nterface = 1-2
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), active(2), inactive(3)  

uas7022TimeSlot16Content 1.3.6.1.4.1.498.6.13.3.1.1.10
Selects the content for TimeSlot 16. Valid [i]nterface = 1-2
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER idle(1), marks(2), data(3)  

uas7022Impedance 1.3.6.1.4.1.498.6.13.3.1.1.11
Selects the impedance. Valid [i]nterface = 1-2
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER impedance120Ohm(1), impedance75Ohm(2)  

uas7022DiagTable 1.3.6.1.4.1.498.6.13.4.1
The Diagnostics table. Information in the entries of this table support diagnostics testing via loopbacks.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Uas7022DiagEntry

uas7022DiagEntry 1.3.6.1.4.1.498.6.13.4.1.1
The Diagnostics table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Uas7022DiagEntry  

uas7022DiagIndex 1.3.6.1.4.1.498.6.13.4.1.1.1
Integer value which uniquely identifies the UAS7022 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (01-02)
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

uas7022DiagConfig 1.3.6.1.4.1.498.6.13.4.1.1.2
Selects the test to run. noLoop(1) ends the test. Valid [i]nterface = 1-2
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noLoop(1), lineLoopback(2), payloadLoopback(3)  

uas7022TestLimit 1.3.6.1.4.1.498.6.13.4.1.1.3
Selects the duration to run a diagnostic test. The value noLimit(3) signifies that the test should run indefinitely until explicitly terminated. Default value: testTime10Mins(1) Valid [i]nterface = 1-2
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER testTime10Mins(1), testTime20Mins(2), noLimit(3)  

uas7022TestExecutionStatus 1.3.6.1.4.1.498.6.13.4.1.1.4
This variable reports the status of a test. notInTest(1) indicates a test is not running. testInProgress(2) indicates that a test is currently running. testCompleted(4) indicates that a test has run and is completed. testCompletedNotInTest(5) indicates that a test has completed and it is no longer in test. Valid [i]nterface = 1-2
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notInTest(1), testInProgress(2), testCompleted(4), testCompletedNotInTest(5)  

uas7022TestExceptions 1.3.6.1.4.1.498.6.13.4.1.1.5
Indicates exceptions that have occurred that may affect interpretation of the test results. The value of this object is a sum. This sum initially take the value zero. Then, for each exception, the value associated with the exception is added to the sum. The exception values are: value exception 1 a timed test was preempted so the result cannot be viewed in relation to the test duration 2 the results overflowed so the result cannot be viewed as an absolute value 4 the test was performed while synchronization could not be performed so the result may not be accurate. Valid [i]nterface = 1-2
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..7  

uas7022NearEndCurrent15MinTable 1.3.6.1.4.1.498.6.13.5.1
The uas7022 Near End Current table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Uas7022NearEndCurrent15MinEntry

uas7022NearEndCurrent15MinEntry 1.3.6.1.4.1.498.6.13.5.1.1
An entry in the uas7022 Near End Current table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Uas7022NearEndCurrent15MinEntry  

uas7022NearEndCurrent15MinIndex 1.3.6.1.4.1.498.6.13.5.1.1.1
Integer value which uniquely identifies the UAS7022 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (01-02)
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

uas7022NearEndCurrent15MinStat 1.3.6.1.4.1.498.6.13.5.1.1.2
Returns a bitwise snapshot of the current 15Min statistics. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 2^9 ES . 1.0 2^7 2.7 f/u 2.6 2^6 . 2.0 2^0 3.7 f/u 3.6 f/u 3.5 f/u 3.4 f/u 3.3 f/u 3.2 2^9 SES . 3.0 2^7 4.7 f/u 4.6 2^6 SES . 4.0 2^0 5.7 f/u 5.6 f/u 5.5 f/u 5.4 f/u 5.3 f/u 5.2 Counter Overflow (>65535) BBE 5.1 2^15 5.0 2^14 6.7 f/u 6.6 2^13 BBE . 6.0 2^7 7.7 f/u 7.6 2^6 BBE . 7.0 2^0 8.7 f/u 8.6 f/u 8.5 f/u 8.4 f/u 8.3 f/u 8.2 2^9 UAS . 8.0 2^7 9.7 f/u 9.6 2^6 UAS . 9.0 2^0 10.7 f/u 10.6 f/u 10.5 f/u 10.4 f/u 10.3 f/u 10.2 Counter Overflow (>65535) LCV 10.1 2^15 10.0 2^14 11.7 f/u 11.6 2^13 LCV . 11.0 2^7 12.7 f/u 12.6 2^6 LCV . 12.0 2^0 Valid [i]nterface = 1-2
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(12)  

uas7022NearEndIntervalTable 1.3.6.1.4.1.498.6.13.5.2
The uas7022 Near End Interval table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Uas7022NearEndIntervalEntry

uas7022NearEndIntervalEntry 1.3.6.1.4.1.498.6.13.5.2.1
An entry in the Near End Interval table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Uas7022NearEndIntervalEntry  

uas7022NearEndIntervalIndex 1.3.6.1.4.1.498.6.13.5.2.1.1
Integer value which uniquely identifies the UAS7022 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (01-02)
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

uas7022NearEndIntervalNumber 1.3.6.1.4.1.498.6.13.5.2.1.2
The number of Errored Seconds encountered by an E1 interface in one of the previous 16, individual 15 minute, intervals.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..16  

uas7022NearEndIntervalStat 1.3.6.1.4.1.498.6.13.5.2.1.3
Returns a bitwise map of the interface in one of the previous 16, individual 15 minute, intervals. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 2^9 ES . 1.0 2^7 2.7 f/u 2.6 2^6 . 2.0 2^0 3.7 f/u 3.6 f/u 3.5 f/u 3.4 f/u 3.3 f/u 3.2 2^9 SES . 3.0 2^7 4.7 f/u 4.6 2^6 SES . 4.0 2^0 5.7 f/u 5.6 f/u 5.5 f/u 5.4 f/u 5.3 f/u 5.2 Counter Overflow (>65535) BBE 5.1 2^15 5.0 2^14 6.7 f/u 6.6 2^13 BBE . 6.0 2^7 7.7 f/u 7.6 2^6 BBE . 7.0 2^0 8.7 f/u 8.6 f/u 8.5 f/u 8.4 f/u 8.3 f/u 8.2 2^9 UAS . 8.0 2^7 9.7 f/u 9.6 2^6 UAS . 9.0 2^0 10.7 f/u 10.6 f/u 10.5 f/u 10.4 f/u 10.3 f/u 10.2 Counter Overflow (>65535) LCV 10.1 2^15 10.0 2^14 11.7 f/u 11.6 2^13 LCV . 11.0 2^7 12.7 f/u 12.6 2^6 LCV . 12.0 2^0 Valid [i]nterface = 1-2
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(12)  

uas7022NearEndCurrent24HrTable 1.3.6.1.4.1.498.6.13.5.3
The Near End Current 24 Hr table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Uas7022NearEndCurrent24HrEntry

uas7022NearEndCurrent24HrEntry 1.3.6.1.4.1.498.6.13.5.3.1
An entry in the Near End Current 24 hr table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Uas7022NearEndCurrent24HrEntry  

uas7022NearEndCurrent24HrIndex 1.3.6.1.4.1.498.6.13.5.3.1.1
Integer value which uniquely identifies the UAS7022 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (01-02)
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

uas7022NearEndCurrent24HrStat 1.3.6.1.4.1.498.6.13.5.3.1.2
Returns a bitwise map of the current 24 hour table 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 1: Counter Overflow (>65535) ES 1.1 2^15 1.0 2^14 2.7 f/u 2.6 2^13 ES . 2.0 2^7 3.7 f/u 3.6 2^6 ES . 3.0 2^0 4.7 f/u 4.6 f/u 4.5 f/u 4.4 f/u 4.3 f/u 4.2 1: Counter Overflow (>65535) SES 4.1 2^15 4.0 2^14 5.7 f/u 5.6 2^13 SES . 5.0 2^7 6.7 f/u 6.6 2^6 SES . 6.0 2^0 7.7 f/u 7.6 f/u 7.5 f/u 7.4 f/u 7.3 f/u 7.2 1: Counter Overflow (>65535) BBE 7.1 2^15 7.0 2^14 8.7 f/u 8.6 2^13 BBE . 8.0 2^7 9.7 f/u 9.6 2^6 BBE . 9.0 2^0 10.7 f/u 10.6 f/u 10.5 f/u 10.4 f/u 10.3 f/u 10.2 1: Counter Overflow (>65535) UAS 10.1 2^15 10.0 2^14 11.7 f/u 11.6 2^13 UAS . 11.0 2^7 12.7 f/u 12.6 2^6 UAS . 12.0 2^0 13.7 f/u 13.6 f/u 13.5 f/u 13.4 f/u 13.3 f/u 13.2 1: Counter Overflow (>65535) LCV 13.1 2^15 13.0 2^14 14.7 f/u 14.6 2^13 LCV . 14.0 2^7 15.7 f/u 15.6 2^6 LCV . 15.0 2^0 Valid [i]nterface = 1-2
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(15)  

uas7022NearEndRecent24HrTable 1.3.6.1.4.1.498.6.13.5.4
The Near End Recent 24Hr table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Uas7022NearEndRecent24HrEntry

uas7022NearEndRecent24HrEntry 1.3.6.1.4.1.498.6.13.5.4.1
An entry in the E1 Total table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Uas7022NearEndRecent24HrEntry  

uas7022NearEndRecent24HrIndex 1.3.6.1.4.1.498.6.13.5.4.1.1
Integer value which uniquely identifies the UAS7022 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (01-02)
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

uas7022NearEndRecent24HrStat 1.3.6.1.4.1.498.6.13.5.4.1.2
Returns a bitwise map of the current 24 hour table 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 1: Counter Overflow (>65535) ES 1.1 2^15 1.0 2^14 2.7 f/u 2.6 2^13 ES . 2.0 2^7 3.7 f/u 3.6 2^6 ES . 3.0 2^0 4.7 f/u 4.6 f/u 4.5 f/u 4.4 f/u 4.3 f/u 4.2 1: Counter Overflow (>65535) SES 4.1 2^15 4.0 2^14 5.7 f/u 5.6 2^13 SES . 5.0 2^7 6.7 f/u 6.6 2^6 SES . 6.0 2^0 7.7 f/u 7.6 f/u 7.5 f/u 7.4 f/u 7.3 f/u 7.2 1: Counter Overflow (>65535) BBE 7.1 2^15 7.0 2^14 8.7 f/u 8.6 2^13 BBE . 8.0 2^7 9.7 f/u 9.6 2^6 BBE . 9.0 2^0 10.7 f/u 10.6 f/u 10.5 f/u 10.4 f/u 10.3 f/u 10.2 1: Counter Overflow (>65535) UAS 10.1 2^15 10.0 2^14 11.7 f/u 11.6 2^13 UAS . 11.0 2^7 12.7 f/u 12.6 2^6 UAS . 12.0 2^0 13.7 f/u 13.6 f/u 13.5 f/u 13.4 f/u 13.3 f/u 13.2 1: Counter Overflow (>65535) LCV 13.1 2^15 13.0 2^14 14.7 f/u 14.6 2^13 LCV . 14.0 2^7 15.7 f/u 15.6 2^6 LCV . 15.0 2^0 Valid [i]nterface = 1-2
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(15)  

uas7022NearEndUnavailableTimeRegTable 1.3.6.1.4.1.498.6.13.5.9
The uas7022 Near End Unavailable Time Register table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Uas7022NearEndUnavailableTimeRegEntry

uas7022NearEndUnavailableTimeRegEntry 1.3.6.1.4.1.498.6.13.5.9.1
An entry in the Near End Unavailable Time Register table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Uas7022NearEndUnavailableTimeRegEntry  

uas7022NearEndUnavailableTimeRegIndex 1.3.6.1.4.1.498.6.13.5.9.1.1
Integer value which uniquely identifies the UAS7022 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (01-02)
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

uas7022NearEndUnavailableTimeRegNumber 1.3.6.1.4.1.498.6.13.5.9.1.2
A number between 1 and 6, where the number is the number of the NearEndUnavailable Time Register. Valid [i]nterface = 1-2
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..6  

uas7022NearEndUnavailableTimeRegStart 1.3.6.1.4.1.498.6.13.5.9.1.3
Start time of one of the NearEndUnavailable Time Registers. Valid [i]nterface = 1-2
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

uas7022NearEndUnavailableTimeRegStop 1.3.6.1.4.1.498.6.13.5.9.1.4
Stop time of one of the NearEndUnavailable Time Registers. Valid [i]nterface = 1-2
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

uas7022FarEndCurrent15MinTable 1.3.6.1.4.1.498.6.13.5.5
The uas7022 Far End Current 15 minute table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Uas7022FarEndCurrent15MinEntry

uas7022FarEndCurrent15MinEntry 1.3.6.1.4.1.498.6.13.5.5.1
An entry in the uas7022 Far End Current 15 Minute table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Uas7022FarEndCurrent15MinEntry  

uas7022FarEndCurrent15MinIndex 1.3.6.1.4.1.498.6.13.5.5.1.1
Integer value which uniquely identifies the UAS7022 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (01-02)
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

uas7022FarEndCurrent15MinStat 1.3.6.1.4.1.498.6.13.5.5.1.2
Returns a bitwise map of the far end interface in one of the previous 16, individual 15 minute, intervals. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 2^9 ES . 1.0 2^7 2.7 f/u 2.6 2^6 . 2.0 2^0 3.7 f/u 3.6 f/u 3.5 f/u 3.4 f/u 3.3 f/u 3.2 2^9 SES . 3.0 2^7 4.7 f/u 4.6 2^6 SES . 4.0 2^0 5.7 f/u 5.6 f/u 5.5 f/u 5.4 f/u 5.3 f/u 5.2 Counter Overflow (>65535) BBE 5.1 2^15 5.0 2^14 6.7 f/u 6.6 2^13 BBE . 6.0 2^7 7.7 f/u 7.6 2^6 BBE . 7.0 2^0 8.7 f/u 8.6 f/u 8.5 f/u 8.4 f/u 8.3 f/u 8.2 2^9 UAS . 8.0 2^7 9.7 f/u 9.6 2^6 UAS . 9.0 2^0 Valid [i]nterface = 1-2
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(9)  

uas7022FarEndIntervalTable 1.3.6.1.4.1.498.6.13.5.6
The uas7022 FarEnd Interval table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Uas7022FarEndIntervalEntry

uas7022FarEndIntervalEntry 1.3.6.1.4.1.498.6.13.5.6.1
An entry in the Interval table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Uas7022FarEndIntervalEntry  

uas7022FarEndIntervalIndex 1.3.6.1.4.1.498.6.13.5.6.1.1
Integer value which uniquely identifies the UAS7022 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (01-02)
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

uas7022FarEndIntervalNumber 1.3.6.1.4.1.498.6.13.5.6.1.2
A number between 1 and 16, where 1 is the most recently completed 15 minute interval and 16 is the least recently completed 15 minutes interval (assuming that all 16 intervals are valid).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..16  

uas7022FarEndIntervalStat 1.3.6.1.4.1.498.6.13.5.6.1.3
Returns a bitwise map of statistics for the far end interface in the current 15 minute interval. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 2^9 ES . 1.0 2^7 2.7 f/u 2.6 2^6 . 2.0 2^0 3.7 f/u 3.6 f/u 3.5 f/u 3.4 f/u 3.3 f/u 3.2 2^9 SES . 3.0 2^7 4.7 f/u 4.6 2^6 SES . 4.0 2^0 5.7 f/u 5.6 f/u 5.5 f/u 5.4 f/u 5.3 f/u 5.2 Counter Overflow (>65535) BBE 5.1 2^15 5.0 2^14 6.7 f/u 6.6 2^13 BBE . 6.0 2^7 7.7 f/u 7.6 2^6 BBE . 7.0 2^0 8.7 f/u 8.6 f/u 8.5 f/u 8.4 f/u 8.3 f/u 8.2 2^9 UAS . 8.0 2^7 9.7 f/u 9.6 2^6 UAS . 9.0 2^0 Valid [i]nterface = 1-2
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(9)  

uas7022FarEndCurrent24HrTable 1.3.6.1.4.1.498.6.13.5.7
The Far End Current 24 Hour table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Uas7022FarEndCurrent24HrEntry

uas7022FarEndCurrent24HrEntry 1.3.6.1.4.1.498.6.13.5.7.1
An entry in the Far End Current 24 Hr table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Uas7022FarEndCurrent24HrEntry  

uas7022FarEndCurrent24HrIndex 1.3.6.1.4.1.498.6.13.5.7.1.1
Integer value which uniquely identifies the UAS7022 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (01-02)
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

uas7022FarEndCurrent24HrStat 1.3.6.1.4.1.498.6.13.5.7.1.2
Returns a bitwise map of statistics for the interface in the current 24 hour interval. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 1: Counter Overflow (>65535) ES 1.1 2^15 1.0 2^14 2.7 f/u 2.6 2^13 ES . 2.0 2^7 3.7 f/u 3.6 2^6 ES . 3.0 2^0 4.7 f/u 4.6 f/u 4.5 f/u 4.4 f/u 4.3 f/u 4.2 1: Counter Overflow (>65535) SES 4.1 2^15 4.0 2^14 5.7 f/u 5.6 2^13 SES . 5.0 2^7 6.7 f/u 6.6 2^6 SES . 6.0 2^0 7.7 f/u 7.6 f/u 7.5 f/u 7.4 f/u 7.3 f/u 7.2 1: Counter Overflow (>65535) BBE 7.1 2^15 7.0 2^14 8.7 f/u 8.6 2^13 BBE . 8.0 2^7 9.7 f/u 9.6 2^6 BBE . 9.0 2^0 10.7 f/u 10.6 f/u 10.5 f/u 10.4 f/u 10.3 f/u 10.2 1: Counter Overflow (>65535) UAS 10.1 2^15 10.0 2^14 11.7 f/u 11.6 2^13 UAS . 11.0 2^7 12.7 f/u 12.6 2^6 UAS . 12.0 2^0 Valid [i]nterface = 1-2
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(12)  

uas7022FarEndRecent24HrTable 1.3.6.1.4.1.498.6.13.5.8
The Far End Recent 24 Hour table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Uas7022FarEndRecent24HrEntry

uas7022FarEndRecent24HrEntry 1.3.6.1.4.1.498.6.13.5.8.1
An entry in the Far End Recent 24 Hr table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Uas7022FarEndRecent24HrEntry  

uas7022FarEndRecent24HrIndex 1.3.6.1.4.1.498.6.13.5.8.1.1
Integer value which uniquely identifies the UAS7022 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (01-02)
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

uas7022FarEndRecent24HrStat 1.3.6.1.4.1.498.6.13.5.8.1.2
Returns a bitwise map of statistics for the interface in the Recent 24 hour interval. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 1: Counter Overflow (>65535) ES 1.1 2^15 1.0 2^14 2.7 f/u 2.6 2^13 ES . 2.0 2^7 3.7 f/u 3.6 2^6 ES . 3.0 2^0 4.7 f/u 4.6 f/u 4.5 f/u 4.4 f/u 4.3 f/u 4.2 1: Counter Overflow (>65535) SES 4.1 2^15 4.0 2^14 5.7 f/u 5.6 2^13 SES . 5.0 2^7 6.7 f/u 6.6 2^6 SES . 6.0 2^0 7.7 f/u 7.6 f/u 7.5 f/u 7.4 f/u 7.3 f/u 7.2 1: Counter Overflow (>65535) BBE 7.1 2^15 7.0 2^14 8.7 f/u 8.6 2^13 BBE . 8.0 2^7 9.7 f/u 9.6 2^6 BBE . 9.0 2^0 10.7 f/u 10.6 f/u 10.5 f/u 10.4 f/u 10.3 f/u 10.2 1: Counter Overflow (>65535) UAS 10.1 2^15 10.0 2^14 11.7 f/u 11.6 2^13 UAS . 11.0 2^7 12.7 f/u 12.6 2^6 UAS . 12.0 2^0 Valid [i]nterface = 1-2
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(12)  

uas7022FarEndUnavailableTimeRegTable 1.3.6.1.4.1.498.6.13.5.10
The uas7022 Far End Unavailable Time Register table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Uas7022FarEndUnavailableTimeRegEntry

uas7022FarEndUnavailableTimeRegEntry 1.3.6.1.4.1.498.6.13.5.10.1
An entry in the Far End Unavailable Time Register table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Uas7022FarEndUnavailableTimeRegEntry  

uas7022FarEndUnavailableTimeRegIndex 1.3.6.1.4.1.498.6.13.5.10.1.1
Integer value which uniquely identifies the UAS7022 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (01-02)
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

uas7022FarEndUnavailableTimeRegNumber 1.3.6.1.4.1.498.6.13.5.10.1.2
A number between 1 and 6, where the number is the number of the Unavailable Time Register. Valid [i]nterface = 1-2
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..6  

uas7022FarEndUnavailableTimeRegStart 1.3.6.1.4.1.498.6.13.5.10.1.3
Start time of one of the Unavailable Time Registers. Valid [i]nterface = 1-2
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

uas7022FarEndUnavailableTimeRegStop 1.3.6.1.4.1.498.6.13.5.10.1.4
Stop time of one of the Unavailable Time Registers. Valid [i]nterface = 1-2
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

uas7022NoResponseAlm 1.3.6.1.4.1.498.6.13.6.1
OBJECT IDENTIFIER    

uas7022DiagRxErrAlm 1.3.6.1.4.1.498.6.13.6.2
OBJECT IDENTIFIER    

uas7022PowerUpAlm 1.3.6.1.4.1.498.6.13.6.3
OBJECT IDENTIFIER    

uas7022TimingLoss 1.3.6.1.4.1.498.6.13.6.4
OBJECT IDENTIFIER    

uas7022LCV 1.3.6.1.4.1.498.6.13.6.5
OBJECT IDENTIFIER    

uas7022LossOfSignal 1.3.6.1.4.1.498.6.13.6.6
OBJECT IDENTIFIER    

uas7022LossOfFrame 1.3.6.1.4.1.498.6.13.6.7
OBJECT IDENTIFIER    

uas7022AlarmIndSignal 1.3.6.1.4.1.498.6.13.6.8
OBJECT IDENTIFIER    

uas7022NEES 1.3.6.1.4.1.498.6.13.6.9
OBJECT IDENTIFIER    

uas7022NEBBE 1.3.6.1.4.1.498.6.13.6.10
OBJECT IDENTIFIER    

uas7022NESES 1.3.6.1.4.1.498.6.13.6.11
OBJECT IDENTIFIER    

uas7022NEUAS 1.3.6.1.4.1.498.6.13.6.12
OBJECT IDENTIFIER    

uas7022FEES 1.3.6.1.4.1.498.6.13.6.13
OBJECT IDENTIFIER    

uas7022FEBBE 1.3.6.1.4.1.498.6.13.6.14
OBJECT IDENTIFIER    

uas7022FESES 1.3.6.1.4.1.498.6.13.6.15
OBJECT IDENTIFIER    

uas7022FEUAS 1.3.6.1.4.1.498.6.13.6.16
OBJECT IDENTIFIER    

uas7022RAI 1.3.6.1.4.1.498.6.13.6.17
OBJECT IDENTIFIER    

uas7022NearEndAlarmConfigTable 1.3.6.1.4.1.498.6.13.7.1
The uas7022NearEndAlarmConfigTable contains entries that configure alarm reporting. The structure of the table is such that alarm configuration is supported on a unit and interface basis, and then on an alarm type basis within the interface.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Uas7022NearEndAlarmConfigEntry

uas7022NearEndAlarmConfigEntry 1.3.6.1.4.1.498.6.13.7.1.1
An entry in the Near End Alarm Configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Uas7022NearEndAlarmConfigEntry  

uas7022NearEndAlarmConfigIndex 1.3.6.1.4.1.498.6.13.7.1.1.1
Integer value which uniquely identifies the UAS7022 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (01-02)
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

uas7022NearEndAlarmConfigIdentifier 1.3.6.1.4.1.498.6.13.7.1.1.2
format: iso.org.dod.internet.private.enterprises.gdc. dsx1.uas7022.uas7022Alarms.ALM example: 1.3.6.1.4.1.498.6.13.6.ALM where ALM = 1 for uas7022NoResponse alarm, 2 for uas7022DiagRxErr alarm, etc., as specified in the Alarm Definitions above.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

uas7022NearEndAlarmCountWindow 1.3.6.1.4.1.498.6.13.7.1.1.3
This variable sets/reads the alarm window. This window is used with the alarm threshold to determine how long the alarm should be active before reporting. Default: disabled(1)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), last1sec(2), last10sec(3), last30sec(4), last1min(5), last15min(6), last1hr(7), last24hr(8), infinite(9)  

uas7022NearEndAlarmCountThreshold 1.3.6.1.4.1.498.6.13.7.1.1.4
This function sets/reads the alarm threshold criteria. This threshold is used along with the the alarm window to determine the number of instances in a given time frame for an alarm to occur before the alarm is considered active. Default: thresGT1(1)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER thresGT1(1), thresGT3(2), thresGT10(3), thresGT100(4), thresGT1000(5), thresGT10000(6)  

uas7022FarEndAlarmConfigTable 1.3.6.1.4.1.498.6.13.7.2
The uas7022FarEndAlarmConfigTable contains entries that configure alarm reporting. The structure of the table is such that alarm configuration is supported on a unit and interface basis, and then on an alarm type basis within the interface.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Uas7022FarEndAlarmConfigEntry

uas7022FarEndAlarmConfigEntry 1.3.6.1.4.1.498.6.13.7.2.1
An entry in the Far End Alarm Configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Uas7022FarEndAlarmConfigEntry  

uas7022FarEndAlarmConfigIndex 1.3.6.1.4.1.498.6.13.7.2.1.1
Integer value which uniquely identifies the UAS7022 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (01-02)
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

uas7022FarEndAlarmConfigIdentifier 1.3.6.1.4.1.498.6.13.7.2.1.2
format: iso.org.dod.internet.private.enterprises.gdc. dsx1.uas7022.uas7022Alarms.ALM example: 1.3.6.1.4.1.498.6.13.6.ALM where ALM = 1 for uas7022NoResponse alarm, 2 for uas7022DiagRxErr alarm, etc., as specified in the Alarm Definitions above.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

uas7022FarEndAlarmCountWindow 1.3.6.1.4.1.498.6.13.7.2.1.3
This variable sets/reads the alarm window. This window is used with the alarm threshold to determine how long the alarm should be active before reporting. Default: disabled(1)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), last1sec(2), last10sec(3), last30sec(4), last1min(5), last15min(6), last1hr(7), last24hr(8), infinite(9)  

uas7022FarEndAlarmCountThreshold 1.3.6.1.4.1.498.6.13.7.2.1.4
This function sets/reads the alarm threshold criteria. This threshold is used along with the the alarm window to determine the number of instances in a given time frame for an alarm to occur before the alarm is considered active. Default: thresGT1(1)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER thresGT1(1), thresGT3(2), thresGT10(3), thresGT100(4), thresGT1000(5), thresGT10000(6)  

uas7022LocalAlarmConfigTable 1.3.6.1.4.1.498.6.13.7.3
The uas7022LocalAlarmConfigTable contains entries that configure alarm reporting to the alarm card.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Uas7022LocalAlarmConfigEntry

uas7022LocalAlarmConfigEntry 1.3.6.1.4.1.498.6.13.7.3.1
An entry in the Local Alarm Configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Uas7022LocalAlarmConfigEntry  

uas7022LocalAlarmConfigIndex 1.3.6.1.4.1.498.6.13.7.3.1.1
Integer value which uniquely identifies the UAS7022 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (01-02)
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

uas7022UASNE 1.3.6.1.4.1.498.6.13.7.3.1.2
Disables or enables the alarm on the Major buss or Minor buss. Valid [i]nterface = 1-2
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

uas7022SESNE 1.3.6.1.4.1.498.6.13.7.3.1.3
Disables or enables the alarm on the Major buss or Minor buss. Valid [i]nterface = 1-2
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

uas7022BBENE 1.3.6.1.4.1.498.6.13.7.3.1.4
Disables or enables the alarm on the Major buss or Minor buss. Valid [i]nterface = 1-2
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

uas7022ESNE 1.3.6.1.4.1.498.6.13.7.3.1.5
Disables or enables the alarm on the Major buss or Minor buss. Valid [i]nterface = 1-2
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

uas7022UASFE 1.3.6.1.4.1.498.6.13.7.3.1.6
Disables or enables the alarm on the Major buss or Minor buss. Valid [i]nterface = 1-2
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

uas7022SESFE 1.3.6.1.4.1.498.6.13.7.3.1.7
Disables or enables the alarm on the Major buss or Minor buss. Valid [i]nterface = 1-2
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

uas7022BBEFE 1.3.6.1.4.1.498.6.13.7.3.1.8
Disables or enables the alarm on the Major buss or Minor buss. Valid [i]nterface = 1-2
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

uas7022ESFE 1.3.6.1.4.1.498.6.13.7.3.1.9
Disables or enables the alarm on the Major buss or Minor buss. Valid [i]nterface = 1-2
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

uas7022LOS 1.3.6.1.4.1.498.6.13.7.3.1.10
Disables or enables the alarm on the Major buss or Minor buss. Valid [i]nterface = 1-2
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

uas7022LOF 1.3.6.1.4.1.498.6.13.7.3.1.11
Disables or enables the alarm on the Major buss or Minor buss. Valid [i]nterface = 1-2
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

uas7022AIS 1.3.6.1.4.1.498.6.13.7.3.1.12
Disables or enables the alarm on the Major buss or Minor buss. Valid [i]nterface = 1-2
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

uas7022TmgLoss 1.3.6.1.4.1.498.6.13.7.3.1.13
Disables or enables the alarm on the Major buss or Minor buss. Valid [i]nterface = 1-2
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

uas7022LCVs 1.3.6.1.4.1.498.6.13.7.3.1.14
Disables or enables the alarm on the Major buss or Minor buss. Valid [i]nterface = 1-2
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

uas7022NtwkRAI 1.3.6.1.4.1.498.6.13.7.3.1.15
Disables or enables the alarm on the Major buss or Minor buss. Valid [i]nterface = 1-2
Status: mandatory Access: read-write
OBJECT-TYPE    