GUDEADS-EPC24X-MIB

File: GUDEADS-EPC24X-MIB.mib (4338 bytes)

Imported modules

SNMPv2-SMI SNMPv2-CONF

Imported symbols

enterprises MODULE-IDENTITY OBJECT-TYPE
Counter32 Integer32 OBJECT-GROUP

Defined Types

Epc24portEntry  
SEQUENCE    
  epc24PortIndex Integer32
  epc24PortName OCTET STRING
  epc24PortState INTEGER
  epc24PortSwitchCount Counter32

Defined Values

gudeads 1.3.6.1.4.1.28507
Tok_String
MODULE-IDENTITY    

epc24Fuse1 1.3.6.1.4.1.28507.5.1.1.3
State of Fuse1 (1 = ok)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..1  

epc24Fuse2 1.3.6.1.4.1.28507.5.1.1.4
State of Fuse2 (1 = ok)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..1  

epc24Fuse3 1.3.6.1.4.1.28507.5.1.1.5
State of Fuse3 (1 = ok)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..1  

gadsEPC24 1.3.6.1.4.1.28507.5
OBJECT IDENTIFIER    

epc24Objects 1.3.6.1.4.1.28507.5.1
OBJECT IDENTIFIER    

epc24powerports 1.3.6.1.4.1.28507.5.1.1
OBJECT IDENTIFIER    

epc24portNumber 1.3.6.1.4.1.28507.5.1.1.1
The number of PowerPorts
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..24  

epc24portTable 1.3.6.1.4.1.28507.5.1.1.2
list of all EPC Powerports
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Epc24portEntry

epc24portEntry 1.3.6.1.4.1.28507.5.1.1.2.1
An entry containing management information applicable to a particular powerport.
Status: current Access: not-accessible
OBJECT-TYPE    
  Epc24portEntry  

epc24PortIndex 1.3.6.1.4.1.28507.5.1.1.2.1.1
A unique value, greater than zero, for each PowerPort.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..24  

epc24PortName 1.3.6.1.4.1.28507.5.1.1.2.1.2
A textual string containing name of a PowerPort.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..15)  

epc24PortState 1.3.6.1.4.1.28507.5.1.1.2.1.3
current state a PowerPort
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(0), on(1)  

epc24PortSwitchCount 1.3.6.1.4.1.28507.5.1.1.2.1.4
The total number of switch actions ocurred on a PowerPort. Does not count switch commands which will not switch the ralay state, so just real relay switches are displayed here.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

epc24Events 1.3.6.1.4.1.28507.5.2
OBJECT IDENTIFIER    

epc24Conf 1.3.6.1.4.1.28507.5.3
OBJECT IDENTIFIER    

epc24Groups 1.3.6.1.4.1.28507.5.3.1
OBJECT IDENTIFIER    

epc24Compls 1.3.6.1.4.1.28507.5.3.2
OBJECT IDENTIFIER    

epc24BasicGroup 1.3.6.1.4.1.28507.5.3.1.1
Basic objects.
Status: current Access: read-only
OBJECT-GROUP