GUDEADS-PDU8110-MIB

File: GUDEADS-PDU8110-MIB.mib (6503 bytes)

Imported modules

SNMPv2-SMI SNMPv2-CONF

Imported symbols

enterprises MODULE-IDENTITY OBJECT-TYPE
NOTIFICATION-TYPE Integer32 Unsigned32
OBJECT-GROUP NOTIFICATION-GROUP

Defined Types

Enc2102PowerEntry  
SEQUENCE    
  pdu8110PowerIndex Integer32
  pdu8110ChanStatus Integer32
  pdu8110Current Unsigned32

Epc8TrapIPEntry  
SEQUENCE    
  pdu8110TrapIPIndex Integer32
  pdu8110TrapAddr OCTET STRING

Pdu8110SensorEntry  
SEQUENCE    
  pdu8110SensorIndex Integer32
  pdu8110TempSensor Integer32
  pdu8110HygroSensor Integer32

Defined Values

gudeads 1.3.6.1.4.1.28507
Tok_String
MODULE-IDENTITY    

pdu8110PowerIndex 1.3.6.1.4.1.28507.23.1.5.1.2.1.1
Index of Power Channel entries
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1  

pdu8110Current 1.3.6.1.4.1.28507.23.1.5.1.2.1.5
Actual Curent on Power Channel.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

pdu8110PowerTable 1.3.6.1.4.1.28507.23.1.5.1.2
All available Channel Interfaces.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Enc2102PowerEntry

pdu8110PowerEntry 1.3.6.1.4.1.28507.23.1.5.1.2.1
An entry containing management information applicable to a particular Power Channel.
Status: current Access: not-accessible
OBJECT-TYPE    
  Enc2102PowerEntry  

pdu8110PowerChan 1.3.6.1.4.1.28507.23.1.5.1
OBJECT IDENTIFIER    

pdu8110ChanStatus 1.3.6.1.4.1.28507.23.1.5.1.2.1.2
0 = data not active, 1 = data valid
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..1  

pdu8110ActivePowerChan 1.3.6.1.4.1.28507.23.1.5.1.1
Number of suppported Power Channels.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 1..2  

events 1.3.6.1.4.1.28507.23.0
OBJECT IDENTIFIER    

pdu8110TrapIPTable 1.3.6.1.4.1.28507.23.1.1.1.2
list of all Trap receiver
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Epc8TrapIPEntry

gadsPDU8110 1.3.6.1.4.1.28507.23
OBJECT IDENTIFIER    

pdu8110TrapIPEntry 1.3.6.1.4.1.28507.23.1.1.1.2.1
an entry containing management informations regarding the list of trap receivers
Status: current Access: not-accessible
OBJECT-TYPE    
  Epc8TrapIPEntry  

pdu8110TrapIPIndex 1.3.6.1.4.1.28507.23.1.1.1.2.1.1
A unique value, greater than zero, for each receiver slot.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..8  

pdu8110DeviceConfig 1.3.6.1.4.1.28507.23.1.2
OBJECT IDENTIFIER    

pdu8110ExtActors 1.3.6.1.4.1.28507.23.1.4
OBJECT IDENTIFIER    

pdu8110ExtSensors 1.3.6.1.4.1.28507.23.1.6
OBJECT IDENTIFIER    

pdu8110SensorTable 1.3.6.1.4.1.28507.23.1.6.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Pdu8110SensorEntry

pdu8110SensorEntry 1.3.6.1.4.1.28507.23.1.6.1.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  Pdu8110SensorEntry  

pdu8110SensorIndex 1.3.6.1.4.1.28507.23.1.6.1.1.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..2  

pdu8110TempSensor 1.3.6.1.4.1.28507.23.1.6.1.1.2
actual temperature, a value of -9999 indicates that data is not available
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

pdu8110HygroSensor 1.3.6.1.4.1.28507.23.1.6.1.1.3
actual humidity, a value of -9999 indicates that data is not available
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

pdu8110SNMPaccess 1.3.6.1.4.1.28507.23.1.1.1
OBJECT IDENTIFIER    

pdu8110TrapCtrl 1.3.6.1.4.1.28507.23.1.1.1.1
0 = off 1 = Ver. 1 2 = Ver. 2c
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..2  

pdu8110Objects 1.3.6.1.4.1.28507.23.1
OBJECT IDENTIFIER    

pdu8110CommonConfig 1.3.6.1.4.1.28507.23.1.1
OBJECT IDENTIFIER    

pdu8110IntActors 1.3.6.1.4.1.28507.23.1.3
OBJECT IDENTIFIER    

pdu8110TrapAddr 1.3.6.1.4.1.28507.23.1.1.1.2.1.2
DNS name or IP address specifying one Trap receiver slot. A port can optionally be specified: 'name:port' An empty string disables this slot.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..99)  

pdu8110IntSensors 1.3.6.1.4.1.28507.23.1.5
OBJECT IDENTIFIER    

pdu8110Conf 1.3.6.1.4.1.28507.23.2
OBJECT IDENTIFIER    

pdu8110Groups 1.3.6.1.4.1.28507.23.2.1
OBJECT IDENTIFIER    

pdu8110Compls 1.3.6.1.4.1.28507.23.2.2
OBJECT IDENTIFIER    

pdu8110TempEvtSen1 1.3.6.1.4.1.28507.23.0.1
temperature limits exceeded
Status: current Access: read-write
NOTIFICATION-TYPE    

pdu8110TempEvtSen2 1.3.6.1.4.1.28507.23.0.2
temperature limits exceeded
Status: current Access: read-write
NOTIFICATION-TYPE    

pdu8110HygroEvtSen1 1.3.6.1.4.1.28507.23.0.3
hygro limits exceeded
Status: current Access: read-write
NOTIFICATION-TYPE    

pdu8110HygroEvtSen2 1.3.6.1.4.1.28507.23.0.4
hygro limits exceeded
Status: current Access: read-write
NOTIFICATION-TYPE    

pdu8110BasicGroup 1.3.6.1.4.1.28507.23.2.1.1
Basic objects.
Status: current Access: read-write
OBJECT-GROUP    

pdu8110NotificationGroup 1.3.6.1.4.1.28507.23.2.1.2
Tok_String
Status: current Access: read-write
NOTIFICATION-GROUP