GUDEADS-PDU8110-MIB
File:
GUDEADS-PDU8110-MIB.mib (6503 bytes)
Imported modules
Imported symbols
Defined Types
Enc2102PowerEntry |
|
SEQUENCE |
|
|
|
|
pdu8110PowerIndex |
Integer32 |
|
|
pdu8110ChanStatus |
Integer32 |
|
|
pdu8110Current |
Unsigned32 |
|
Epc8TrapIPEntry |
|
SEQUENCE |
|
|
|
|
pdu8110TrapIPIndex |
Integer32 |
|
|
pdu8110TrapAddr |
OCTET STRING |
|
Pdu8110SensorEntry |
|
SEQUENCE |
|
|
|
|
pdu8110SensorIndex |
Integer32 |
|
|
pdu8110TempSensor |
Integer32 |
|
|
pdu8110HygroSensor |
Integer32 |
|
Defined Values
gudeads |
1.3.6.1.4.1.28507 |
Tok_String |
MODULE-IDENTITY |
|
|
|
pdu8110PowerIndex |
1.3.6.1.4.1.28507.23.1.5.1.2.1.1 |
Index of Power Channel entries |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1 |
|
pdu8110Current |
1.3.6.1.4.1.28507.23.1.5.1.2.1.5 |
Actual Curent on Power Channel. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
pdu8110PowerEntry |
1.3.6.1.4.1.28507.23.1.5.1.2.1 |
An entry containing management information
applicable to a particular Power Channel. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Enc2102PowerEntry |
|
|
pdu8110ChanStatus |
1.3.6.1.4.1.28507.23.1.5.1.2.1.2 |
0 = data not active, 1 = data valid |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..1 |
|
events |
1.3.6.1.4.1.28507.23.0 |
OBJECT IDENTIFIER |
|
|
|
pdu8110TrapIPEntry |
1.3.6.1.4.1.28507.23.1.1.1.2.1 |
an entry containing management
informations regarding the list of trap
receivers |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Epc8TrapIPEntry |
|
|
pdu8110TrapIPIndex |
1.3.6.1.4.1.28507.23.1.1.1.2.1.1 |
A unique value, greater than zero, for each receiver slot. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1..8 |
|
pdu8110SensorEntry |
1.3.6.1.4.1.28507.23.1.6.1.1 |
Tok_String |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Pdu8110SensorEntry |
|
|
pdu8110TempSensor |
1.3.6.1.4.1.28507.23.1.6.1.1.2 |
actual temperature, a value of -9999 indicates
that data is not available |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
pdu8110HygroSensor |
1.3.6.1.4.1.28507.23.1.6.1.1.3 |
actual humidity, a value of -9999 indicates
that data is not available |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
pdu8110TrapCtrl |
1.3.6.1.4.1.28507.23.1.1.1.1 |
0 = off
1 = Ver. 1
2 = Ver. 2c |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..2 |
|
pdu8110TrapAddr |
1.3.6.1.4.1.28507.23.1.1.1.2.1.2 |
DNS name or IP address specifying one Trap receiver slot.
A port can optionally be specified: 'name:port' An empty
string disables this slot. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..99) |
|
pdu8110TempEvtSen1 |
1.3.6.1.4.1.28507.23.0.1 |
temperature limits exceeded |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
pdu8110TempEvtSen2 |
1.3.6.1.4.1.28507.23.0.2 |
temperature limits exceeded |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
pdu8110HygroEvtSen1 |
1.3.6.1.4.1.28507.23.0.3 |
hygro limits exceeded |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
pdu8110HygroEvtSen2 |
1.3.6.1.4.1.28507.23.0.4 |
hygro limits exceeded |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
pdu8110BasicGroup |
1.3.6.1.4.1.28507.23.2.1.1 |
Basic objects. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|