H3C-HPEOC-MIB
File:
H3C-HPEOC-MIB.mib (15027 bytes)
Imported modules
Imported symbols
Defined Types
H3cHPEOCCltVlanManEntry |
|
SEQUENCE |
|
|
|
|
h3cHPEOCCltEthPortType |
INTEGER |
|
H3cHPEOCCltSysManEntry |
|
SEQUENCE |
|
|
|
|
h3cHPEOCCltDescr |
DisplayString |
|
|
h3cHPEOCCltFwVersion |
DisplayString |
|
H3cHPEOCCnuSysManEntry |
|
SEQUENCE |
|
|
|
|
h3cHPEOCCnuBcastControl |
TruthValue |
|
|
h3cHPEOCCnuAnonymStatus |
TruthValue |
|
|
h3cHPEOCCnuMacLimit |
Unsigned32 |
|
H3cHPEOCCableInfoEntry |
|
SEQUENCE |
|
|
|
|
h3cHPEOCFECErrors |
Counter64 |
|
|
h3cHPEOCAvgBitsPerCarrier |
Unsigned32 |
|
|
h3cHPEOCAvgSNRPerCarrier |
Integer32 |
|
|
h3cHPEOCAvgInPBCRCErrors |
Unsigned32 |
|
|
h3cHPEOCInTotalPkts |
Counter64 |
|
|
h3cHPEOCAvgOutPower |
Integer32 |
|
|
h3cHPEOCAvgOutPBCRCErrors |
Unsigned32 |
|
|
h3cHPEOCOutTotalPkts |
Counter64 |
|
H3cHPEOCBitPerSymbolEntry |
|
SEQUENCE |
|
|
|
|
h3cHPEOCBitPerSymbolIndex |
Unsigned32 |
|
|
h3cHPEOCBitPerSymbol |
OCTET STRING |
|
Defined Values
h3cHPEOC |
1.3.6.1.4.1.2011.10.2.84 |
The objects in this MIB module are used to manage and
display current configuration of Ethernet Over Cable
Network (EOC) which based on HomePlug(HP) AV Specification.
|
MODULE-IDENTITY |
|
|
|
h3cHPEOCCltVlanType |
1.3.6.1.4.1.2011.10.2.84.1.1 |
Control EOC CLT's VLAN type,
ieee8021q : 802.1q VLAN mode,
portbased : portbased VLAN mode.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
ieee8021q(1), portbased(2) |
|
h3cHPEOCCltVlanManEntry |
1.3.6.1.4.1.2011.10.2.84.1.2.1 |
The entry of the table h3cHPEOCCltVlanManTable.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
H3cHPEOCCltVlanManEntry |
|
|
h3cHPEOCCltEthPortType |
1.3.6.1.4.1.2011.10.2.84.1.2.1.1 |
Control CLT ethernet ports' type,
normal : port which used for normal translation,
debug : port which used for debug.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
normal(1), debug(2) |
|
h3cHPEOCCltSysManEntry |
1.3.6.1.4.1.2011.10.2.84.1.3.1 |
The entry of the table h3cHPEOCCltSysManTable.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
H3cHPEOCCltSysManEntry |
|
|
h3cHPEOCCltDescr |
1.3.6.1.4.1.2011.10.2.84.1.3.1.1 |
Set the description of CLT.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..126) |
|
h3cHPEOCCltFwVersion |
1.3.6.1.4.1.2011.10.2.84.1.3.1.2 |
EOC firmware version. If the object length is
zero, it means the version is unknown.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
h3cHPEOCCnuSysManEntry |
1.3.6.1.4.1.2011.10.2.84.1.4.1 |
The entry of the table h3cHPEOCCnuSysManTable.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
H3cHPEOCCnuSysManEntry |
|
|
h3cHPEOCCnuBcastControl |
1.3.6.1.4.1.2011.10.2.84.1.4.1.1 |
Broadcast storm suppression status.
true(1) - Broadcast storm suppression enable.
false(2) - Broadcast storm suppression disable.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
h3cHPEOCCnuAnonymStatus |
1.3.6.1.4.1.2011.10.2.84.1.4.1.2 |
Anonymity status.
true(1) - the user which uses the CNU is anonymous.
false(2) - the user which uses the CNU has an account.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
h3cHPEOCCnuMacLimit |
1.3.6.1.4.1.2011.10.2.84.1.4.1.3 |
Configure the max number of MAC address entries which can access
through the CNU, it ranges from 1 to 8.
Otherwise,
If configure 0, the CNU won't limit the MAC address entry.
If configure 0xFF, it means no MAC address entry can access the CNU.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
h3cHPEOCCltAutoUpgrade |
1.3.6.1.4.1.2011.10.2.84.1.5 |
Auto upgrade Status.
true(1) - The firmware of the CNU will be auto changed by CLT.
false(2)- The firmware of the CNU will not be auto changed.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
h3cHPEOCCltAutoUpgradeType |
1.3.6.1.4.1.2011.10.2.84.1.10 |
Type of auto upgrade status.
It depends on h3cHPEOCCltAutoUpgrade status.
flash - The CLT auto upgrade the firmware inside its flash
to the CNUs.
ftp - First download the firmware from FTP server to the CLT,
then the CLT auto upgrade the firmware to the CNUs.
tftp - First download the firmware from TFTP server to the CLT,
then the CLT auto upgrade the firmware to the CNUs.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
flash(1), ftp(2), tftp(3) |
|
h3cHPEOCServerAddress |
1.3.6.1.4.1.2011.10.2.84.1.11.1 |
The address of remote host acting as server for operation.
The default value is 0.0.0.0
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
IpAddress |
|
|
h3cHPEOCServerUser |
1.3.6.1.4.1.2011.10.2.84.1.11.2 |
When using ftp to transfer files, the user name must be
specified through this node. It contains 1 to 30 characters.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
h3cHPEOCServerPassword |
1.3.6.1.4.1.2011.10.2.84.1.11.3 |
Remote user password for copying via ftp protocol. Optionally,
this object may be ignored for protocols other than ftp.
It contains 1 to 31 characters.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
h3cHPEOCCableInfoEntry |
1.3.6.1.4.1.2011.10.2.84.2.1.1 |
The entry of the table h3cHPEOCCableInfoTable.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
H3cHPEOCCableInfoEntry |
|
|
h3cHPEOCFECErrors |
1.3.6.1.4.1.2011.10.2.84.2.1.1.1 |
The cable port's FEC bits errors ratio. FEC means the
payload Forward Error Correction. It's a technology of
controlling errors. Packets in transmission is checked by
the receiver, if error occurs, the receiver will announce
the sender to resend.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter64 |
|
|
h3cHPEOCAvgSNRPerCarrier |
1.3.6.1.4.1.2011.10.2.84.2.1.1.3 |
The cable port's signal noise ratio(SNR) bits per carrier.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
h3cHPEOCInTotalPkts |
1.3.6.1.4.1.2011.10.2.84.2.1.1.5 |
The total number of packets(including bad packets)
received on this interface.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter64 |
|
|
h3cHPEOCAvgOutPower |
1.3.6.1.4.1.2011.10.2.84.2.1.1.6 |
The cable port's power sent on average, the unit is db.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
h3cHPEOCAvgOutPBCRCErrors |
1.3.6.1.4.1.2011.10.2.84.2.1.1.7 |
The cable port's physical block(PB) cyclic redundancy
check(CRC) errors sent on average.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
h3cHPEOCOutTotalPkts |
1.3.6.1.4.1.2011.10.2.84.2.1.1.8 |
The total count of the packets(including bad packets)
sent on this interface.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter64 |
|
|
h3cHPEOCBitPerSymbolEntry |
1.3.6.1.4.1.2011.10.2.84.2.2.1 |
The entry of the table h3cHPEOCBitPerSymbolTable.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
H3cHPEOCBitPerSymbolEntry |
|
|
h3cHPEOCBitPerSymbol |
1.3.6.1.4.1.2011.10.2.84.2.2.1.2 |
h3cHPEOCBitPerSymbol returns all the bits per symbol on the fixed
frequency. Each 4 bits stand for one value, all the values
picking-up will make up a cable bit map.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|