HH3C-COMMON-SYSTEM-MIB
File:
HH3C-COMMON-SYSTEM-MIB.mib (10199 bytes)
Imported modules
Imported symbols
Defined Values
hh3cSystem |
1.3.6.1.4.1.25506.6 |
This file describes common MIB objects implemented by
both Routers and Switches. |
MODULE-IDENTITY |
|
|
|
hh3cWriteConfig |
1.3.6.1.4.1.25506.6.5 |
Write config to router. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
save(1) |
|
hh3cStartFtpServer |
1.3.6.1.4.1.25506.6.6 |
Decide whether start ftp-server.enable(1) indicates to start ftp-server;
disable(2) indicates to stop ftp-server. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
enable(1), disable(2) |
|
hh3cReboot |
1.3.6.1.4.1.25506.6.7 |
normal:do nothing.
reboot :reboot the router.
'normal' will be returned when getting. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
normal(0), reboot(1) |
|
hh3cWriteSuccessTrap |
1.3.6.1.4.1.25506.6.8.1 |
Send a trap about write success. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hh3cWriteFailureTrap |
1.3.6.1.4.1.25506.6.8.2 |
Send a trap about write failure. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hh3cRebootSendTrap |
1.3.6.1.4.1.25506.6.8.3 |
If a user restarts the device with command
'reboot', this trap will be sent two seconds
before the device reboots. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hh3cSysColdStartTrap |
1.3.6.1.4.1.25506.6.8.4 |
System cold start trap. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hh3cSysWarmStartTrap |
1.3.6.1.4.1.25506.6.8.5 |
System warm start trap. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hh3cSysLoghostUnreachableTrap |
1.3.6.1.4.1.25506.6.8.6 |
This notification will be sent when a loghost becomes unreachable. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hh3cSysBootType |
1.3.6.1.4.1.25506.6.10 |
Boot type of the system, indicates whether the last device reboot was by
CLI (warm start) or power off (cold start). |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
coldStart(1), warmStart(2) |
|
hh3cSysStatisticPeriod |
1.3.6.1.4.1.25506.6.11.1 |
Statistic period. The device collects statistics
within the period. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..900 |
|
hh3cSysSamplePeriod |
1.3.6.1.4.1.25506.6.11.2 |
Sampling period. The device takes samples periodically
for statistics collection. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..300 |
|
hh3cSysTrapResendPeriod |
1.3.6.1.4.1.25506.6.11.3 |
Trap resending period. If the value is zero, the trap
will not be re-sent. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..3600 |
|
hh3cSysTrapCollectionPeriod |
1.3.6.1.4.1.25506.6.11.4 |
Trap collecting period. If the value is zero, the trap
will not be re-sent. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..60 |
|
hh3cSysSnmpPort |
1.3.6.1.4.1.25506.6.11.5 |
UDP port for SNMP protocol entity to receive messages except Trap-PDU. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
hh3cSysSnmpTrapPort |
1.3.6.1.4.1.25506.6.11.6 |
UDP port for Trap-PDU to receive messages. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
hh3cSysNetID |
1.3.6.1.4.1.25506.6.11.7 |
System Net ID. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..127) |
|
hh3cSysTrapSendNum |
1.3.6.1.4.1.25506.6.11.9 |
Maximum number of times for sending a trap. If the value is zero,
a trap will be sent at an interval continually. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..24 |
|
hh3cSysFirstTrapTime |
1.3.6.1.4.1.25506.6.11.10 |
Time when the first trap is sent. |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
TimeTicks |
|
|
hh3cSysBannerMOTD |
1.3.6.1.4.1.25506.6.11.11 |
An administratively configured message that is displayed
to the user when the user logs in to the device through
the console port or Web interface. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..2000) |
|