HH3C-RMON-EXT2-MIB

File: HH3C-RMON-EXT2-MIB.mib (15090 bytes)

Imported modules

SNMPv2-TC SNMPv2-SMI RMON-MIB
HH3C-OID-MIB

Imported symbols

DisplayString OBJECT-TYPE MODULE-IDENTITY
OBJECT-IDENTITY NOTIFICATION-TYPE Integer32
OwnerString EntryStatus hh3cCommon

Defined Types

Hh3cRmonExtAlarmEntry  
SEQUENCE    
  hh3cRmonExtAlarmIndex Integer32
  hh3cRmonExtAlarmInterval Integer32
  hh3cRmonExtAlarmVariable DisplayString
  hh3cRmonExtAlarmSympol DisplayString
  hh3cRmonExtAlarmSampleType INTEGER
  hh3cRmonExtAlarmValue Integer32
  hh3cRmonExtAlarmStartupAlarm INTEGER
  hh3cRmonExtAlarmRisingThreshold Integer32
  hh3cRmonExtAlarmFallingThreshold Integer32
  hh3cRmonExtAlarmRisingEvtIndex Integer32
  hh3cRmonExtAlarmFallingEvtIndex Integer32
  hh3cRmonExtAlarmStatCycle Integer32
  hh3cRmonExtAlarmStatType INTEGER
  hh3cRmonExtAlarmOwner OwnerString
  hh3cRmonExtAlarmStatus EntryStatus

Defined Values

hh3cRmonExt 1.3.6.1.4.1.25506.2.125
The private MIB module for managing remote monitoring device implementations.
MODULE-IDENTITY    

hh3cRmonExtAlarmTable 1.3.6.1.4.1.25506.2.125.1
A list of alarm entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Hh3cRmonExtAlarmEntry

hh3cRmonExtAlarmEntry 1.3.6.1.4.1.25506.2.125.1.1
A list of parameters that set up a periodic checking for alarm conditions. For example, an instance of the alarmValue object might be named alarmValue.8
Status: current Access: not-accessible
OBJECT-TYPE    
  Hh3cRmonExtAlarmEntry  

hh3cRmonExtAlarmIndex 1.3.6.1.4.1.25506.2.125.1.1.1
An index that uniquely identifies an entry in the alarm table. Each such entry defines a diagnostic sample at a particular interval for an object on the device.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..65535  

hh3cRmonExtAlarmInterval 1.3.6.1.4.1.25506.2.125.1.1.2
The interval in seconds over which the data is sampled and compared with the rising and falling thresholds. When setting this variable, care should be taken in the case of deltaValue sampling - the interval should be set short enough that the sampled variable is very unlikely to increase or decrease by more than 2^31 - 1 during a single sampling interval. This object may not be modified if the associated alarmStatus object is equal to valid.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 10..65535  

hh3cRmonExtAlarmVariable 1.3.6.1.4.1.25506.2.125.1.1.3
The object identifier of the particular variable to be sampled. Only variables that resolve to an ASN.1 primitive type of INTEGER (INTEGER, Integer32, Unsigned32, Counter32, Counter64, Gauge, or TimeTicks) may be sampled. Because SNMP access control is articulated entirely in terms of the contents of MIB views, no access control mechanism exists that can restrict the value of this object to identify only those objects that exist in a particular MIB view. Because there is thus no acceptable means of restricting the read access that could be obtained through the alarm mechanism, the probe must only grant write access to this object in those views that have read access to all objects on the probe. During a set operation, if the supplied variable name is not available in the selected MIB view, a badValue error must be returned. This object may not be modified if the associated alarmStatus object is equal to valid.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString  

hh3cRmonExtAlarmSympol 1.3.6.1.4.1.25506.2.125.1.1.4
A comment describing this alarm entry. This object may not be modified if the associated alarmStatus object is equal to valid.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString  

hh3cRmonExtAlarmSampleType 1.3.6.1.4.1.25506.2.125.1.1.5
The method of sampling the selected variable and calculating the value to be compared against the thresholds. If the value of this object is absoluteValue, the value of the selected variable will be compared directly with the thresholds at the end of the sampling interval. If the value of this object is deltaValue, the value of the selected variable at the last sample will be subtracted from the current value, and the difference compared with the thresholds. This object may not be modified if the associated alarmStatus object is equal to valid.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER absoluteValue(1), deltaValue(2), speedValue(3)  

hh3cRmonExtAlarmValue 1.3.6.1.4.1.25506.2.125.1.1.6
The value of the statistic during the last sampling period. For example, if the sample type is deltaValue, this value will be the difference between the samples at the beginning and end of the period. If the sample type is absoluteValue, this value will be the sampled value at the end of the period. This is the value that is compared with the rising and falling thresholds. The value during the current sampling period is not made available until the period is completed and will remain available until the next period completes.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cRmonExtAlarmStartupAlarm 1.3.6.1.4.1.25506.2.125.1.1.7
The alarm that may be sent when this entry is first set to valid. If the first sample after this entry becomes valid is greater than or equal to the risingThreshold and alarmStartupAlarm is equal to risingAlarm or risingOrFallingAlarm, then a single rising alarm will be generated. If the first sample after this entry becomes valid is less than or equal to the fallingThreshold and alarmStartupAlarm is equal to fallingAlarm or risingOrFallingAlarm, then a single falling alarm will be generated. This object may not be modified if the associated alarmStatus object is equal to valid.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER risingAlarm(1), fallingAlarm(2), risingOrFallingAlarm(3)  

hh3cRmonExtAlarmRisingThreshold 1.3.6.1.4.1.25506.2.125.1.1.8
A threshold for the sampled statistic. When the current sampled value is greater than or equal to this threshold, and the value at the last sampling interval was less than this threshold, a single event will be generated. A single event will also be generated if the first sample after this entry becomes valid is greater than or equal to this threshold and the associated alarmStartupAlarm is equal to risingAlarm or risingOrFallingAlarm. After a rising event is generated, another such event will not be generated until the sampled value falls below this threshold and reaches the alarmFallingThreshold. This object may not be modified if the associated alarmStatus object is equal to valid.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

hh3cRmonExtAlarmFallingThreshold 1.3.6.1.4.1.25506.2.125.1.1.9
A threshold for the sampled statistic. When the current sampled value is less than or equal to this threshold, and the value at the last sampling interval was greater than this threshold, a single event will be generated. A single event will also be generated if the first sample after this entry becomes valid is less than or equal to this threshold and the associated alarmStartupAlarm is equal to fallingAlarm or risingOrFallingAlarm. After a falling event is generated, another such event will not be generated until the sampled value rises above this threshold and reaches the alarmRisingThreshold. This object may not be modified if the associated alarmStatus object is equal to valid.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

hh3cRmonExtAlarmRisingEvtIndex 1.3.6.1.4.1.25506.2.125.1.1.10
The index of the eventEntry that is used when a rising threshold is crossed. The eventEntry identified by a particular value of this index is the same as identified by the same value of the eventIndex object. If there is no corresponding entry in the eventTable, then no association exists. In particular, if this value is zero, no associated event will be generated, as zero is not a valid event index. This object may not be modified if the associated alarmStatus object is equal to valid.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..65535  

hh3cRmonExtAlarmFallingEvtIndex 1.3.6.1.4.1.25506.2.125.1.1.11
The index of the eventEntry that is used when a falling threshold is crossed. The eventEntry identified by a particular value of this index is the same as identified by the same value of the eventIndex object. If there is no corresponding entry in the eventTable, then no association exists. In particular, if this value is zero, no associated event will be generated, as zero is not a valid event index. This object may not be modified if the associated alarmStatus object is equal to valid.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..65535  

hh3cRmonExtAlarmStatCycle 1.3.6.1.4.1.25506.2.125.1.1.12
The lifetime (in seconds) starts when an alarm entry is set in valid state. If the entry has an infinite lifetime, the value of this object MUST be 0. Otherwise the value MUST be greater than the value of hh3cRmonExtAlarmInterval. This object may not be modified if the associated alarmStatus object is equal to valid.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..4294967  

hh3cRmonExtAlarmStatType 1.3.6.1.4.1.25506.2.125.1.1.13
This object indicates whether the entry has an infinite or limited lifetime. This object may not be modified if the associated alarmStatus object is equal to valid.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER forever(1), during(2)  

hh3cRmonExtAlarmOwner 1.3.6.1.4.1.25506.2.125.1.1.14
The entity that configured this entry and is therefore using the resources assigned to it. The defalut value of this object is zero length string.
Status: current Access: read-create
OBJECT-TYPE    
  OwnerString  

hh3cRmonExtAlarmStatus 1.3.6.1.4.1.25506.2.125.1.1.15
The status of this alarm entry.
Status: current Access: read-create
OBJECT-TYPE    
  EntryStatus  

hh3cRmonExtEvent 1.3.6.1.4.1.25506.2.125.0
Definition point for notifications.
Status: current Access: read-create
OBJECT-IDENTITY    

hh3cRmonExtRisingAlarm 1.3.6.1.4.1.25506.2.125.0.1
The SNMP trap that is generated when an alarm entry crosses its rising threshold and generates an event that is configured for sending SNMP traps.
Status: current Access: read-create
NOTIFICATION-TYPE    

hh3cRmonExtFallingAlarm 1.3.6.1.4.1.25506.2.125.0.2
The SNMP trap that is generated when an alarm entry crosses its falling threshold and generates an event that is configured for sending SNMP traps.
Status: current Access: read-create
NOTIFICATION-TYPE