HMRINGARC-MGMT-SNMP-MIB

File: HMRINGARC-MGMT-SNMP-MIB.mib (13711 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC HMRING-MGMT-SNMP-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
OBJECT-IDENTITY IpAddress Integer32
Unsigned32 DisplayString hmRingRedundancy

Defined Types

HmArcCheckResultEntry  
SEQUENCE    
  hmArcCheckStatusIndex Integer32
  hmArcCheckStatusDeviceMac OCTET STRING
  hmArcCheckStatusDeviceIp IpAddress
  hmArcCheckStatusType INTEGER
  hmArcCheckStatusInfo DisplayString
  hmArcCheckStatusClassification INTEGER

Defined Values

hmARC 1.3.6.1.4.1.248.14.5.7
The Hirschmann Private Automatic Ring Configuration MIB definitions.
MODULE-IDENTITY    

hmArcManagerConfig 1.3.6.1.4.1.248.14.5.7.1
OBJECT IDENTIFIER    

hmArcManagerStatus 1.3.6.1.4.1.248.14.5.7.2
OBJECT IDENTIFIER    

hmArcClientConfig 1.3.6.1.4.1.248.14.5.7.3
OBJECT IDENTIFIER    

hmArcClientStatus 1.3.6.1.4.1.248.14.5.7.4
OBJECT IDENTIFIER    

hmArcManagerAdminStatus 1.3.6.1.4.1.248.14.5.7.1.1
The administratively desired status of the ARC manager. enabled(1): ARC manager is active, the device can check and configure other ARC devices. disabled(2): ARC manager is inactive, neither checking nor automatic configuring can be done.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

hmArcManagerRedProtocol 1.3.6.1.4.1.248.14.5.7.1.2
The ring redundancy protocol the clients will be configured for. Parameters like VLAN ID and timings are taken from the current redundancy manager configuration. mrp(1): Media Redundancy Protocol, according to IEC62439-2.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER mrp(1)  

hmArcManagerPrimGroupID 1.3.6.1.4.1.248.14.5.7.1.3
Unique index to identify the slot number of the primary link of the ARC manager. This value is never greater than hmSysGroupCapacity.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hmArcManagerPrimIfIndex 1.3.6.1.4.1.248.14.5.7.1.4
Interface index of the primary link of the ARC manager.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hmArcManagerRedGroupID 1.3.6.1.4.1.248.14.5.7.1.5
Unique index to identify the slot number of the redundant link of the ARC manager. This value is never greater than hmSysGroupCapacity.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hmArcManagerRedIfIndex 1.3.6.1.4.1.248.14.5.7.1.6
Interface index of the redundant link of the ARC manager.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hmArcManagerVlanID 1.3.6.1.4.1.248.14.5.7.1.7
VLAN identifier of the ARC manager. If value is set to 0 no VLAN is assigned.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hmArcManagerAction 1.3.6.1.4.1.248.14.5.7.1.8
The actions the ARC manager is able to activate. This object, when read, returns noAction(1) if no action is currently running. checkTopology(2): Checks the topology connected to the given primary and redundant port and also fills the hmArcCheckResultTable, especially if an invalid topology was found. configureRing(3): Automatically configures the ring devices connected to the given primary and redundant port. A successful checkTopology is prerequisite.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noAction(1), checkTopology(2), configureRing(3)  

hmArcManagerActionResult 1.3.6.1.4.1.248.14.5.7.1.9
Result of the last activated action. noAction(1): Initial state, no action started. pending(2): A topology check or a configuration process is going on. closedRing(3): The topology check detected a ring topology which is ready for automatic configuration. configuredRing(4): The topology check detected a partly or fully configured ring. See the hmArcCheckResultTable for details. You may reconfigure it using ARC. openRing(5): The topology check detected an open ring. It cannot be configured by ARC. invalidTopology(6): An invalid topology was detected. See the hmArcCheckResultTable for details. configFailed(7): One or more devices in the ring could not activate the configuration and are not properly configured. configSuccessful(8): The automatic configuration process was successful.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noAction(1), pending(2), closedRing(3), configuredRing(4), openRing(5), invalidTopology(6), configFailed(7), configSuccessful(8)  

hmArcCheckResultTable 1.3.6.1.4.1.248.14.5.7.2.1
Every entry in this table contains information about the status of the network topology reported by the ARC devices.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HmArcCheckResultEntry

hmArcCheckResultEntry 1.3.6.1.4.1.248.14.5.7.2.1.1
An entry in the hmArcCheckResultTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  HmArcCheckResultEntry  

hmArcCheckStatusIndex 1.3.6.1.4.1.248.14.5.7.2.1.1.1
Index for the table
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hmArcCheckStatusDeviceMac 1.3.6.1.4.1.248.14.5.7.2.1.1.2
The MAC address of the ARC device that reported the status.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

hmArcCheckStatusDeviceIp 1.3.6.1.4.1.248.14.5.7.2.1.1.3
The IP address of the ARC device that reported the status.
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

hmArcCheckStatusType 1.3.6.1.4.1.248.14.5.7.2.1.1.4
The status an ARC device in the connected topology reported. otherRm(1): the device detected another active Redundancy Manager. loop(2): unclear topology detected. This may be a loop or a net segment which is connected to the ring with Rapid Spanning Tree. alreadyConfigured(3): the device already has a ring configured. unsupportedOption(4): the device does not support one of the ARC Manager options. openRing(5): the ARC Manager has detected an open Ring. configFailed(6): the configuration of the device failed. duplexMode(7): at least one Ring Port of the device is not in full duplex mode. noArcDevices(8): there is no device in the ring which supports the ARC Protocol, or all devices have hmArcClientAdminStatus set to disabled. portState(9): at least one Ring Port of the device is not properly configured. info(10): the device reported just additional information.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER otherRm(1), loop(2), alreadyConfigured(3), unsupportedOption(4), openRing(5), configFailed(6), duplexMode(7), noArcDevices(8), portState(9), info(10)  

hmArcCheckStatusInfo 1.3.6.1.4.1.248.14.5.7.2.1.1.5
Additional information about the ARC device status. The device may provide this information for each value in hmArcCheckStatusType.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

hmArcCheckStatusClassification 1.3.6.1.4.1.248.14.5.7.2.1.1.6
Classification of the status the ARC device reported. error(1): the reported status is an error. warning(2): the reported status is a warning. ok(3): the reported status is an information.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER error(1), warning(2), ok(3)  

hmArcClientAdminStatus 1.3.6.1.4.1.248.14.5.7.3.1
The administratively desired status of the ARC client. enabled(1): ARC client is active, the device can be configured automatically and can return a status on a topology check. disabled(2): ARC client is inactive, neither checking nor automatic configuring can be done. checkOnly(3): The ARC client returns a status on a topology check but it's not possible to configure the device automatically.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), checkOnly(3)  

hmArcClientManagerDeviceMac 1.3.6.1.4.1.248.14.5.7.4.1
The MAC address of the ARC manager that last checked or configured the device.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

hmArcClientManagerDeviceIp 1.3.6.1.4.1.248.14.5.7.4.2
The IP address of the ARC manager that last checked or configured the device.
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

hmArcClientPrimGroupID 1.3.6.1.4.1.248.14.5.7.4.3
Unique index to identify the slot number of the to be configured primary link port. This value is never greater than hmSysGroupCapacity.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hmArcClientPrimIfIndex 1.3.6.1.4.1.248.14.5.7.4.4
Interface index of the to be configured primary link.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hmArcClientRedGroupID 1.3.6.1.4.1.248.14.5.7.4.5
Unique index to identify the slot number of the to be configured redundant link port. This value is never greater than hmSysGroupCapacity.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hmArcClientRedIfIndex 1.3.6.1.4.1.248.14.5.7.4.6
Interface index of the to be configured redundant link.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32