Defined Types

HpRptrBasicGroupEntry  
SEQUENCE    
  hpRptrGrpGroupIndex Integer32
  hpRptrGrpPortsAdminStatus OCTET STRING
  hpRptrGrpPortsSegStatus OCTET STRING
  hpRptrGrpPortsMediaAvailable OCTET STRING
  hpRptrGrpPortsLinkbeatEnabled OCTET STRING
  hpRptrGrpPortsOperStatus OCTET STRING

HpRptrBasicPtEntry  
SEQUENCE    
  hpRptrPtGroupIndex Integer32
  hpRptrPtPortIndex Integer32
  hpRptrPtLinkbeatEnable TruthValue
  hpRptrPtPolarityReversed TruthValue
  hpRptrPtSqeEnabled TruthValue
  hpRptrPtMediaAvailTrapEnable TruthValue
  hpRptrPtLongCableEnable TruthValue

HpRptrMonPtEntry  
SEQUENCE    
  hpRptrMonPtGroupIndex Integer32
  hpRptrMonPtPortIndex Integer32
  hpRptrMonPtUcastPackets Counter32
  hpRptrMonPtBcastPackets Counter32
  hpRptrMonPtMcastPackets Counter32

HpRpMauEntry  
SEQUENCE    
  hpRpMauTypeList BITS
  hpRpMauAutoNegSupported TruthValue
  hpRpMauAutoNegAdminStatus INTEGER
  hpRpMauAutoNegRemoteSignaling INTEGER
  hpRpMauAutoNegConfig INTEGER
  hpRpMauAutoNegCapReceived BITS
  hpRpMauAutoNegRestart INTEGER

Defined Values

hpicf8023RptrMib 1.3.6.1.4.1.11.2.14.10.2.9
This MIB module contains objects that provide HP-specific extensions to the 802.3 Repeater MIB.
MODULE-IDENTITY    

hpRptrBasic 1.3.6.1.4.1.11.2.14.11.2.1
OBJECT IDENTIFIER    

hpRptrBasicGlobal 1.3.6.1.4.1.11.2.14.11.2.1.1
OBJECT IDENTIFIER    

hpRptrEntityName 1.3.6.1.4.1.11.2.14.11.2.1.1.1
********* THIS OBJECT IS DEPRECATED ********* The local name of this repeater. This is the same value as hpicfEntityName in the case where there is Distributed Management Protocol to access this device. For SNMPv1, this name is appended to the agent community name to obtain a community name to use to specify that the agent should proxy to this repeater. For example, if this agent has a community with a community name of 'public', and the value of this object is 'repeater1', the community 'public/repeater1' will specify that the agent should proxy to the public community of the repeater1 box to obtain management information about this repeater. If an agent receives a management request where the localEntity is not specified, it will default to the local repeater on which this agent is executing. This object has been deprecated. Since it is a scalar, it does not scale to systems containing multiple repeater segments. In addition, it is only considered useful in systems supporting the Distributed Management Chain, which has also been deprecated.
Status: deprecated Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..15)  

hpRptrThinlanFault 1.3.6.1.4.1.11.2.14.11.2.1.1.2
********* THIS OBJECT IS DEPRECATED ********* When set to 'true' this object causes the Fault Led to blink if the ThinLan Port is segmented. This object has been deprecated. It only makes sense in systems that support a single BNC port.
Status: deprecated Access: read-write
OBJECT-TYPE    
  TruthValue  

hpRptrSqeEnabled 1.3.6.1.4.1.11.2.14.11.2.1.1.3
********* THIS OBJECT IS DEPRECATED ********* When 'true', this flag indicates that SQE has been detected for the last ten agent transmits and there is a high probability that the SQE switch on the transceiver attached to the AUI port is set to Enabled, when it should be Disabled. This object has been deprecated, since it presumes that the system will only have a single AUI port. It has been replaced by the hpRptrPtSqeEnabled object.
Status: deprecated Access: read-only
OBJECT-TYPE    
  TruthValue  

hpRptrRobustHealing 1.3.6.1.4.1.11.2.14.11.2.1.1.4
********* THIS OBJECT IS DEPRECATED ********* When this flag is set to 'true', it enables robust port healing mode. The 802.3 specification states that a segmented port is healed by successfully transmitting or receiving a packet on the port. This mode disables port healing on successful packet reception and requires that a packet be successfully transmitted on a port in order for a segmented port to be healed.
Status: deprecated Access: read-write
OBJECT-TYPE    
  TruthValue  

hpRptrBasicGroup 1.3.6.1.4.1.11.2.14.11.2.1.2
OBJECT IDENTIFIER    

hpRptrBasicGroupTable 1.3.6.1.4.1.11.2.14.11.2.1.2.1
********* THIS OBJECT IS DEPRECATED ********* HP specific extensions to the rptrGroupTable.
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HpRptrBasicGroupEntry

hpRptrBasicGroupEntry 1.3.6.1.4.1.11.2.14.11.2.1.2.1.1
********* THIS OBJECT IS DEPRECATED ********* An entry in the table, containing HP extensions for a specific group.
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  HpRptrBasicGroupEntry  

hpRptrGrpGroupIndex 1.3.6.1.4.1.11.2.14.11.2.1.2.1.1.1
********* THIS OBJECT IS DEPRECATED ********* The group within the repeater for which this entry contains information. This object has the same value as the corresponding instance of rptrGroupIndex.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Integer32 1..2147483647  

hpRptrGrpPortsAdminStatus 1.3.6.1.4.1.11.2.14.11.2.1.2.1.1.2
********* THIS OBJECT IS DEPRECATED ********* The hpRptrGrpPortsAdminStatus is a bit map of the state of the rptrPortAdminStatus object for all of the ports in this group. The object has a one bit for each port for which the value of rptrPortAdminStatus is equal to 'enabled(1)' and a zero bit for each port for which the value of rptrPortAdminStatus is equal to 'disabled(2)'. The bits are placed into the OCTET STRING in the following order: octet 0 octet 1 octet 2 ... bits 7-0 bits 7-0 bits 7-0 ... ports 1-8 ports 9-16 ports 17-24 ... Values of unused bits in the last octet are undefined.
Status: deprecated Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..128)  

hpRptrGrpPortsSegStatus 1.3.6.1.4.1.11.2.14.11.2.1.2.1.1.3
********* THIS OBJECT IS DEPRECATED ********* The hpRptrGrpPortsSegStatus is a bit map of the state of the rptrPortAutoPartitionState of all of the ports in this group. The object has a one bit for each port for which the value of rptrPortAutoPartitionState is equal to 'notAutoPartitioned(1)' and a zero bit for each port for which the value of rptrPortAutoPartitionState is equal to 'autoPartitioned(2)'. The bits are placed into the OCTET STRING in the following order: octet 0 octet 1 octet 2 ... bits 7-0 bits 7-0 bits 7-0 ... ports 1-8 ports 9-16 ports 17-24 ... Values of unused bits in the last octet are undefined.
Status: deprecated Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..128)  

hpRptrGrpPortsMediaAvailable 1.3.6.1.4.1.11.2.14.11.2.1.2.1.1.4
********* THIS OBJECT IS DEPRECATED ********* The hpRptrGrpPortsMediaAvailable is a bit map of the state of the rpMauMediaAvailable object for all of the ports in this group. The object has a one bit for each port for which the value of rpMauMediaAvailable is equal to 'available(3)' and a zero bit for each port for which the value of rpMauMediaAvailable is not equal to 'available(3)'. The bits are placed into the OCTET STRING in the following order: octet 0 octet 1 octet 2 ... bits 7-0 bits 7-0 bits 7-0 ... ports 1-8 ports 9-16 ports 17-24 ... Values of unused bits in the last octet are undefined.
Status: deprecated Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..128)  

hpRptrGrpPortsLinkbeatEnabled 1.3.6.1.4.1.11.2.14.11.2.1.2.1.1.5
********* THIS OBJECT IS DEPRECATED ********* The hpRptrGrpPortsLinkbeatEnabled is a bit map of the state of the hpRptrPtLinkbeatEnable object for all of the ports in this group. The object has a one bit for each port for which the value of hpRptrPtLinkbeatEnable is equal to 'true(1)' and a zero bit for each port for which the value of hpRptrPtLinkbeatEnable is equal to 'false(2)'. The bits are placed into the OCTET STRING in the following order: octet 0 octet 1 octet 2 ... bits 7-0 bits 7-0 bits 7-0 ... ports 1-8 ports 9-16 ports 17-24 ... Values of unused bits in the last octet are undefined.
Status: deprecated Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..128)  

hpRptrGrpPortsOperStatus 1.3.6.1.4.1.11.2.14.11.2.1.2.1.1.6
********* THIS OBJECT IS DEPRECATED ********* The hpRptrGrpPortsOperStatus is a bit map of the state of all hub ports in the group. The object has a 1 bit for each port that is enabled, not segmented, and the media is available. Ports on which these conditions are not true have a 0 bit. The bits are placed into the OCTET STRING in the following order: octet 0 octet 1 octet 2 ... bits 7-0 bits 7-0 bits 7-0 ... ports 1-8 ports 9-16 ports 17-24 ... Values of unused bits in the last octet are undefined.
Status: deprecated Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..128)  

hpRptrBasicPort 1.3.6.1.4.1.11.2.14.11.2.1.3
OBJECT IDENTIFIER    

hpRptrBasicPtTable 1.3.6.1.4.1.11.2.14.11.2.1.3.1
HP specific extensions to the rptrPortTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HpRptrBasicPtEntry

hpRptrBasicPtEntry 1.3.6.1.4.1.11.2.14.11.2.1.3.1.1
An entry in the table, containing HP extensions for a specific port.
Status: current Access: not-accessible
OBJECT-TYPE    
  HpRptrBasicPtEntry  

hpRptrPtGroupIndex 1.3.6.1.4.1.11.2.14.11.2.1.3.1.1.1
The group containing the port for which this entry contains information. This object has the same value as the corresponding instance of rptrPortGroupIndex.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..2147483647  

hpRptrPtPortIndex 1.3.6.1.4.1.11.2.14.11.2.1.3.1.1.2
The port within the group for which this entry contains information. This object has the same value as the corresponding instance of rptrPortIndex.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..2147483647  

hpRptrPtLinkbeatEnable 1.3.6.1.4.1.11.2.14.11.2.1.3.1.1.3
When this flag is set to 'true' the port's link beat is enabled and when set to 'false' it is disabled.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

hpRptrPtPolarityReversed 1.3.6.1.4.1.11.2.14.11.2.1.3.1.1.4
This object is used to indicate that the hub port was wired with the positive/negative polarity of its transmit and receive pairs reversed. Note that the port will continue to operate in this state, with the hub inverting the polarity internally.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

hpRptrPtSqeEnabled 1.3.6.1.4.1.11.2.14.11.2.1.3.1.1.5
When 'true', this flag indicates that SQE has been detected for the last ten agent transmits and there is a high probability that the SQE switch on the transceiver attached to this port is set to Enabled, when it should be Disabled. This value can only be 'true' on AUI ports.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

hpRptrPtMediaAvailTrapEnable 1.3.6.1.4.1.11.2.14.11.2.1.3.1.1.6
Indicates whether hpicfMediaAvailDetectTrap and hpicfMediaAvailLostTrap events should be generated for MAUs attached to this port. This object has the value of 'false' by default. Setting the value of this object to 'true' will cause a hpicfMediaAvailDetectTrap event to be generated whenever an instance of rpMauMediaAvailable object associated with a MAU attached to this port enters the 'available' state, and a hpicfMediaAvailLostTrap to be generated whenever an instance of the rpMauMediaAvailable object associated with a MAU attached to this port exits the 'available' state. Note that the disposition of these events is controlled by the RMON eventTable. We recommend that this object is only be set to 'true' on important ports, such as cascade ports and ports attached to routers bridges, switches, or servers. Setting this object to 'true' on other ports may cause irrelevant traps. For example, it is unlikely that an administrator would want to receive a trap every time a user turns their PC off.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

hpRptrPtLongCableEnable 1.3.6.1.4.1.11.2.14.11.2.1.3.1.1.7
When this flag is set to 'true' the port's squelch level will be reduced to account for extended distance connections. When set to 'false', this port's squelch level will be normal. We recommend that this object only be set to 'true' for ports that are actually connected to long cables.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

hpRptrMonitor 1.3.6.1.4.1.11.2.14.11.2.2
OBJECT IDENTIFIER    

hpRptrMonitorGlobal 1.3.6.1.4.1.11.2.14.11.2.2.1
OBJECT IDENTIFIER    

hpRptrMonCounters 1.3.6.1.4.1.11.2.14.11.2.2.1.1
OBJECT IDENTIFIER    

hpRptrMonGlobalFrames 1.3.6.1.4.1.11.2.14.11.2.2.1.1.1
********* THIS OBJECT IS DEPRECATED ********* The total number of frames of valid frame length that have been received on all ports in this repeater. This counter is the summation of the values of the rptrMonitorPortReadableFrames counter for all of the ports in this repeater. Equivalently, this counter is the summation of the values of the rptrMonitorGroupTotalFrames counter for all of the port groups in this repeater.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Counter32  

hpRptrMonGlobalOctets 1.3.6.1.4.1.11.2.14.11.2.2.1.1.2
********* THIS OBJECT IS DEPRECATED ********* The total number of octets contained in the valid frames that have been received on the ports in this repeater. This counter is the summation of the values of the rptrMonitorPortReadableOctets counter for all of the ports in this repeater. Equivalently, this counter is the summation of the values of the rptrMonitorGroupTotalOctets counter for all of the port groups in this repeater.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Counter32  

hpRptrMonGlobalFCSErrors 1.3.6.1.4.1.11.2.14.11.2.2.1.1.3
********* THIS OBJECT IS DEPRECATED ********* This counter is incremented by one for each frame received on any port with the FCSError signal asserted and the FramingError and CollisionEvent signals deasserted and whose OctetCount is greater than or equal to minFrameSize and less than or equal to maxFrameSize (Ref: 4.4.2.1, IEEE 802.3 Std). This counter is the summation of the values of the rptrMonitorPortFCSErrors counter for all of the ports in this repeater.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Counter32  

hpRptrMonGlobalAlignmentErrors 1.3.6.1.4.1.11.2.14.11.2.2.1.1.4
********* THIS OBJECT IS DEPRECATED ********* This counter is incremented by one for each frame received on any port with the FCSError and FramingError signals asserted and CollisonEvent signal deasserted and whose OctetCount is greater than or equal to minFrameSize and less than or equal to maxFrameSize (Ref: 4.4.2.1, IEEE 802.3 Std). If hpRptrMonGlobalAlignmentErrors is incremented, then the hpRptrMonGlobalFCSErorrs counter shall not be incremented for the same frame. This counter is the summation of the values of the rptrMonitorPortAlignmentErrors counter for all of the ports in this repeater.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Counter32  

hpRptrMonGlobalFrameTooLongs 1.3.6.1.4.1.11.2.14.11.2.2.1.1.5
********* THIS OBJECT IS DEPRECATED ********* This counter is incremented by one for each frame received on any port whose OctetCount is greater than maxFrameSize (Ref: 4.4.2.1, IEEE 802.3 Std). If hpRptrMonGlobalFrameTooLongs is incremented, then neither the hpRptrMonGlobalAlignmentErorrs nor the hpRptrMonGlobalFCSErrors counter shall be incremented for the frame. This counter is the summation of the values of the rptrMonitorPortFrameTooLongs counter for all of the ports in this repeater.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Counter32  

hpRptrMonGlobalShortEvents 1.3.6.1.4.1.11.2.14.11.2.2.1.1.6
********* THIS OBJECT IS DEPRECATED ********* This counter is incremented by one for each CarrierEvent on any port with ActivityDuration less than ShortEventMaxTime. ShortEventMaxTime is greater than 74 bit times and less than 82 bit times. ShortEventMaxTime has tolerances included to provide for circuit losses between a conformance test point at the AUI and the measurement point within the state machine. This counter is the summation of the values of the rptrMonitorPortShortEvents counter for all of the ports in this repeater.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Counter32  

hpRptrMonGlobalRunts 1.3.6.1.4.1.11.2.14.11.2.2.1.1.7
********* THIS OBJECT IS DEPRECATED ********* This counter is incremented by one for each CarrierEvent on any port that meets one of the following two conditions. Only one test need be made. a) The ActivityDuration is greater than ShortEventMaxTime and less than ValidPacketMinTime and the CollisionEvent signal is deasserted. b) The OctetCount is less than 64, the ActivityDuration is greater than ShortEventMaxTime and the CollisionEvent signal is deasserted. ValidPacketMinTime is greater than or equal to 552 bit times but less than 565 bit times. An event whose length is greater than 74 bit times but less than 82 bit times shall increment either the hpRptrMonGlobalShortEvents counter or the hpRptrMonGlobalRunts counter but not both. A CarrierEvent greater than or equal to 552 bit times but less than 565 bit times may or may not increment the hpRptrMonGlobalRunts counter. ValidPacketMinTime has tolerances included to provide for circuit losses between a conformance test point at the AUI and the measurement point within the state machine. Runts usually indicate collision fragments, a normal network event. This counter is the summation of the values of the rptrMonitorPortRunts counter for all of the ports in this repeater.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Counter32  

hpRptrMonGlobalCollisions 1.3.6.1.4.1.11.2.14.11.2.2.1.1.8
********* THIS OBJECT IS DEPRECATED ********* This counter is incremented by one for any CarrierEvent signal on any port for which the CollisionEvent signal on any port is asserted. This counter differs from rptrMonitorTransmitCollisions in that it counts all collisions seen by this repeater, even those involving only a single port on this repeater, whereas rptrMonitorTransmitCollisions counts only collisions involving multiple ports on this repeater.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Counter32  

hpRptrMonGlobalLateEvents 1.3.6.1.4.1.11.2.14.11.2.2.1.1.9
********* THIS OBJECT IS DEPRECATED ********* This counter is incremented by one for each CarrierEvent on any port in which the CollIn(X) variable transitions to the value SQE (Ref: 9.6.6.2, IEEE 802.3 Std) while the ActivityDuration is greater than the LateEventThreshold. Such a CarrierEvent is counted twice, as both hpRptrMonGlobalCollisions and hpRptrMonGlobalLateEvents. The LateEventThreshold is greater than 480 bit times and less than 565 bit times. LateEventThreshold has tolerances included to permit an implementation to build a single threshold to serve as both the LateEventThreshold and ValidPacketMinTime threshold. This counter is the summation of the values of the rptrMonitorPortLateEvents counter for all of the ports in this repeater.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Counter32  

hpRptrMonGlobalVeryLongEvents 1.3.6.1.4.1.11.2.14.11.2.2.1.1.10
********* THIS OBJECT IS DEPRECATED ********* This counter is incremented by one for each CarrierEvent on any port whose ActivityDuration is greater than the MAU Jabber Lockup Protection timer TW3 (Ref: 9.6.1 & 9.6.5, IEEE 802.3 Std). Other counters may be incremented as appropriate. This counter is the summation of the values of the rptrMonitorPortVeryLongEvents counter for all of the ports in this repeater.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Counter32  

hpRptrMonGlobalDataRateMismatches 1.3.6.1.4.1.11.2.14.11.2.2.1.1.11
********* THIS OBJECT IS DEPRECATED ********* This counter is incremented by one for each frame received on any port that meets all of the following conditions: a) The CollisionEvent signal is not asserted. b) The ActivityDuration is greater than ValidPacketMinTime. c) The frequency (data rate) is detectably mismatched from the local transmit frequency. The exact degree of mismatch is vendor specific and is to be defined by the vendor for conformance testing. When this event occurs, other counters whose increment conditions were satisfied may or may not also be incremented. This counter is the summation of the values of the rptrMonitorPortDatRateMismatches counter for all of the ports in this repeater.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Counter32  

hpRptrMonGlobalAutoPartitions 1.3.6.1.4.1.11.2.14.11.2.2.1.1.12
********* THIS OBJECT IS DEPRECATED ********* This counter is incremented by one for each time the repeater has automatically partitioned any port. The conditions that cause port partitioning are specified in the partition state machine in Section 9 of the IEEE 802.3 Std. This counter is the summation of the values of the rptrMonitorPortAutoPartitions for all of the ports in this repeater.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Counter32  

hpRptrMonGlobalErrors 1.3.6.1.4.1.11.2.14.11.2.2.1.1.13
********* THIS OBJECT IS DEPRECATED ********* The total number of errors which have occured on any port in this repeater. This counter is the summation of the values of other error counters, namely: hpRptrMonGlobalFCSErrors, hpRptrMonGlobalAlignmentErrors, hpRptrMonGlobalFrameTooLongs, hpRptrMonGlobalShortEvents, hpRptrMonGlobalLateEvents, hpRptrMonGlobalVeryLongEvents, and hpRptrMonGlobalDataRateMismatches. Equivalently, this counter is the summation of the values of the rptrMonitorPortTotalErrors counter for all of the ports in this repeater, or it is the summation of the values of rptrMonitorGroupTotalErrors for all of the port groups in this repeater.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Counter32  

hpRptrMonGlobalUcastPackets 1.3.6.1.4.1.11.2.14.11.2.2.1.1.14
********* THIS OBJECT IS DEPRECATED ********* This counter is incremented by one for each unicast packet of valid frame length received on any port. This counter is the summation of hpRptrMonPortUcastPackets for all of the ports in this repeater. This counter may not be implemented for repeaters which do not have a local network management agent.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Counter32  

hpRptrMonGlobalBcastPackets 1.3.6.1.4.1.11.2.14.11.2.2.1.1.15
********* THIS OBJECT IS DEPRECATED ********* This counter is incremented by one for each broadcast packet of valid frame length received on any port. This counter is the summation of hpRptrMonPortBcastPackets for all of the ports in this repeater. This counter may not be implemented for repeaters which do not have a local network management agent.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Counter32  

hpRptrMonGlobalMcastPackets 1.3.6.1.4.1.11.2.14.11.2.2.1.1.16
********* THIS OBJECT IS DEPRECATED ********* This counter is incremented by one for each multicast packet of valid frame length received on any port. This counter is the summation of hpRptrMonPortMcastPackets for all of the ports in this repeater. This counter may not be implemented for repeaters which do not have a local network management agent.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Counter32  

hpRptrMonitorGroup 1.3.6.1.4.1.11.2.14.11.2.2.2
OBJECT IDENTIFIER    

hpRptrMonitorPort 1.3.6.1.4.1.11.2.14.11.2.2.3
OBJECT IDENTIFIER    

hpRptrMonPtTable 1.3.6.1.4.1.11.2.14.11.2.2.3.1
Table of HP specific per port monitor objects.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HpRptrMonPtEntry

hpRptrMonPtEntry 1.3.6.1.4.1.11.2.14.11.2.2.3.1.1
An entry in the table, containing per port objects for a single port.
Status: current Access: not-accessible
OBJECT-TYPE    
  HpRptrMonPtEntry  

hpRptrMonPtGroupIndex 1.3.6.1.4.1.11.2.14.11.2.2.3.1.1.1
The group containing the port for which this entry contains information. This object has the same value as the corresponding instance of rptrMonitorPortGroupIndex.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..2147483647  

hpRptrMonPtPortIndex 1.3.6.1.4.1.11.2.14.11.2.2.3.1.1.2
The port within the group for which this entry contains information. This object has the same value as the corresponding instance of rptrMonitorPortIndex.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..2147483647  

hpRptrMonPtUcastPackets 1.3.6.1.4.1.11.2.14.11.2.2.3.1.1.3
This counter is incremented by one for each unicast packet of valid frame length received on this port. This object may not be implemented for repeaters which do not have a local network management agent.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

hpRptrMonPtBcastPackets 1.3.6.1.4.1.11.2.14.11.2.2.3.1.1.4
This counter is incremented by one for each broadcast packet of valid frame length received on this port. This object may not be implemented for repeaters which do not have a local network management agent.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

hpRptrMonPtMcastPackets 1.3.6.1.4.1.11.2.14.11.2.2.3.1.1.5
This counter is incremented by one for each multicast packet of valid frame length received on this port. This object may not be implemented for repeaters which do not have a local network management agent.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

hpRpMauGroup 1.3.6.1.4.1.11.2.14.11.2.4
OBJECT IDENTIFIER    

hpRpMauTable 1.3.6.1.4.1.11.2.14.11.2.4.1
HP extensions to the rpMauTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HpRpMauEntry

hpRpMauEntry 1.3.6.1.4.1.11.2.14.11.2.4.1.1
An entry in the table, containing HP extensions for a single MAU.
Status: current Access: not-accessible
OBJECT-TYPE    
  HpRpMauEntry  

hpRpMauTypeList 1.3.6.1.4.1.11.2.14.11.2.4.1.1.1
A value that uniquely identifies the set of possible IEEE 802.3 types that the MAU could be. If auto-negotiation is present on this MAU, this object will map to hpRpMauAutoNegCapability. Note that a repeater can never actually support the full-duplex MAU types. The bits for them are retained to keep the bit values consistent with ifMauTypeListBits.
Status: current Access: read-only
OBJECT-TYPE    
  BITS bOther(0), bAUI(1), b10base5(2), bFoirl(3), b10base2(4), b10baseT(5), b10baseFP(6), b10baseFB(7), b10baseFL(8), b10broad36(9), b10baseTHD(10), b10baseTFD(11), b10baseFLHD(12), b10baseFLFD(13), b100baseT4(14), b100baseTXHD(15), b100baseTXFD(16), b100baseFXHD(17), b100baseFXFD(18), b100baseT2HD(19), b100baseT2FD(20)  

hpRpMauAutoNegSupported 1.3.6.1.4.1.11.2.14.11.2.4.1.1.2
This object indicates whether or not auto-negotiation is supported on this MAU.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

hpRpMauAutoNegAdminStatus 1.3.6.1.4.1.11.2.14.11.2.4.1.1.3
Setting this object to autoNegotiate(1) will cause auto-negotiation to be enabled on this port. Setting this object to forceTo100TXHD will cause auto-negotiation to be disabled on this port, and cause the operational type of the MAU on this port (as reported by rpMauType) to transition to dot3MauType100BaseTXHD. Setting this object to forceTo10THD will cause auto-negotiation to be disabled on this port, and cause the operational type of the MAU on this port (as reported by rpMauType) to transition to dot3MauType10BaseTHD.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER autoNegotiate(1), forceTo100TXHD(2), forceTo10THD(3)  

hpRpMauAutoNegRemoteSignaling 1.3.6.1.4.1.11.2.14.11.2.4.1.1.4
A value indicating whether the remote end of the link is using auto-negotiation signaling. It takes the value detected(1) if and only if, during the previous link negotiation, FLP Bursts were received.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER detected(1), notdetected(2)  

hpRpMauAutoNegConfig 1.3.6.1.4.1.11.2.14.11.2.4.1.1.5
A value indicating the current status of the auto-negotiation process. The enumeration parallelDetectFail(5) maps to a failure in parallel detection as defined in 28.2.3.1 of [IEEE 802.3 Std].
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER other(1), configuring(2), complete(3), disabled(4), parallelDetectFail(5)  

hpRpMauAutoNegCapReceived 1.3.6.1.4.1.11.2.14.11.2.4.1.1.6
A value that uniquely identifies the set of capabilities received from the remote auto-negotiation entity. Note that ports that support this MIB may be attached to remote auto-negotiation entities which have capabilities beyond the scope of this MIB.
Status: current Access: read-only
OBJECT-TYPE    
  BITS bOther(0), b10baseT(1), b10baseTFD(2), b100baseT4(3), b100baseTX(4), b100baseTXFD(5), b100baseT2(6), b100baseT2FD(7)  

hpRpMauAutoNegRestart 1.3.6.1.4.1.11.2.14.11.2.4.1.1.7
If the value of this object is set to restart(1) then this will force auto-negotiation to begin link renegotiation. If auto-negotiation signaling is disabled, a write to this object has no effect. Setting the value of this object to norestart(2) has no effect.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER restart(1), norestart(2)  

hpicfLinkBeatTrap 1.3.6.1.4.1.11.2.14.12.2.0.1
********* THIS NOTIFICATION IS DEPRECATED ********* A hpicfLinkBeatTrap is device type specific to ICF hubs. It signifies that the hub hardware has detected a change of state in a port's link beat status. The current value of the port's link beat status is returned in the PDU. This trap has been deprecated. It is replaced by the hpicfMediaAvailDetectTrap and the hpicfMediaAvailLostTrap.
Status: deprecated Access: read-write
NOTIFICATION-TYPE    

hpicfPartitionTrap 1.3.6.1.4.1.11.2.14.12.2.0.2
********* THIS NOTIFICATION IS DEPRECATED ********* A hpicfPartitionTrap is device type specific to ICF hubs. It signifies that the hub hardware has detected a change of state in a port's partition status. The current value of the port's partition status is returned in the PDU. This trap has been deprecated. It is replaced by the hpicfPortPartitionTrap and the hpicfPortHealTrap.
Status: deprecated Access: read-write
NOTIFICATION-TYPE    

hpicfMediaAvailDetectTrap 1.3.6.1.4.1.11.2.14.12.2.0.3
A hpicfMediaAvailDetectTraps is device type specific to ICF hubs. It signifies that the hub hardware has detected an instance of rpMauMediaAvailable for one of the repeater's ports has entered the 'available' state from some other state. Note that this trap is only generated for instances of rpMauMediaAvailable associated with MAUs attached to repeater ports for which the corresponding instance of the hpRptrPtMediaAvailTrapEnable object is equal to 'true'. The previous value of the instance of the rpMauMediaAvailable object that entered the 'active' state is returned in the PDU.
Status: current Access: read-write
NOTIFICATION-TYPE    

hpicfMediaAvailLostTrap 1.3.6.1.4.1.11.2.14.12.2.0.4
A hpicfMediaAvailLostTraps is device type specific to ICF hubs. It signifies that the hub hardware has detected an instance of rpMauMediaAvailable for one of the repeater's ports that had been in the 'available' state has exited that state. Note that this trap is only generated for instances of rpMauMediaAvailable associated with MAUs attached to repeater ports for which the corresponding instance of the hpRptrPtMediaAvailTrapEnable object is equal to 'true'. The new value of the instance of the rpMauMediaAvailable object that exited the 'active' state is returned in the PDU.
Status: current Access: read-write
NOTIFICATION-TYPE    

hpicfPortPartitionTrap 1.3.6.1.4.1.11.2.14.12.2.0.5
A hpicfPortPartitionTrap is device type specific to ICF hubs. It signifies that the hub hardware has detected that an instance of rptrPortAutoPartitionState for one of the repeater's ports has changed from the 'notAutoPartitioned' state to the 'autoPartitioned' state. The current value of the instance of the rptrPortAutoPartitionState for the port that auto-partitioned is returned in the PDU.
Status: current Access: read-write
NOTIFICATION-TYPE    

hpicfPortHealTrap 1.3.6.1.4.1.11.2.14.12.2.0.6
A hpicfPortHealTrap is device type specific to ICF hubs. It signifies that the hub hardware has detected that an instance of rptrPortAutoPartitionState for one of the repeater's ports has changed from the 'autoPartitioned' state to the 'notAutoPartitioned' state. The current value of the instance of the rptrPortAutoPartitionState for the port that healed is returned in the PDU.
Status: current Access: read-write
NOTIFICATION-TYPE    

hpicf8023RptrConformance 1.3.6.1.4.1.11.2.14.10.2.9.1
OBJECT IDENTIFIER    

hpicf8023RptrCompliances 1.3.6.1.4.1.11.2.14.10.2.9.1.1
OBJECT IDENTIFIER    

hpicf8023RptrGroups 1.3.6.1.4.1.11.2.14.10.2.9.1.2
OBJECT IDENTIFIER    

hpicf8023RptrCompliance 1.3.6.1.4.1.11.2.14.10.2.9.1.1.1
********* THIS COMPLIANCE IS DEPRECATED ********* The compliance statement for HP extensions to the 802.3 Repeater MIB for HP AdvanceStack 802.3 repeaters.
Status: deprecated Access: read-write
MODULE-COMPLIANCE    

hpicf8023RptrSlaveCompliance 1.3.6.1.4.1.11.2.14.10.2.9.1.1.2
********* THIS COMPLIANCE IS DEPRECATED ********* The compliance statement for HP extensions to the 802.3 Repeater MIB for HP AdvanceStack 802.3 slave repeaters.
Status: deprecated Access: read-write
MODULE-COMPLIANCE    

hpicf8023MultiRptrCompliance 1.3.6.1.4.1.11.2.14.10.2.9.1.1.3
The compliance statement for HP extensions to the 802.3 Repeater MIB for HP AdvanceStack 802.3 repeaters. This compliance supports devices with multiple repeater segments, as well as devices with a single repeater segment.
Status: current Access: read-write
MODULE-COMPLIANCE    

hpicf8023RptrAutoNegCompliance 1.3.6.1.4.1.11.2.14.10.2.9.1.1.4
The compliance statement for HP extensions to the 802.3 Repeater MIB for HP AdvanceStack 802.3 repeaters. This compliance supports devices with multiple repeater segments, as well as devices with a single repeater segment. It also supports repeater devices with auto-negotiation.
Status: current Access: read-write
MODULE-COMPLIANCE    

hpicf8023RptrBasicGroup 1.3.6.1.4.1.11.2.14.10.2.9.1.2.1
********* THIS GROUP IS DEPRECATED ********* A collection of HP specific extensions to the 802.3 Repeater MIB for the HP AdvanceStack product line.
Status: deprecated Access: read-write
OBJECT-GROUP    

hpicf8023RptrBasicSlaveGroup 1.3.6.1.4.1.11.2.14.10.2.9.1.2.2
********* THIS GROUP IS DEPRECATED ********* A collection of HP specific extensions to the 802.3 Repeater MIB for HP AdvanceStack slaves.
Status: deprecated Access: read-write
OBJECT-GROUP    

hpicf8023RptrMonitorGroup 1.3.6.1.4.1.11.2.14.10.2.9.1.2.3
********* THIS GROUP IS DEPRECATED ********* A collection of extended counters for 802.3 repeaters in the HP AdvanceStack product line.
Status: deprecated Access: read-write
OBJECT-GROUP    

hpicf8023RptrMonitorSlaveGroup 1.3.6.1.4.1.11.2.14.10.2.9.1.2.4
********* THIS GROUP IS DEPRECATED ********* A collection of extended counters for HP AdvanceStack 802.3 slave repeaters.
Status: deprecated Access: read-write
OBJECT-GROUP    

hpicf8023MultiRptrBasicGroup 1.3.6.1.4.1.11.2.14.10.2.9.1.2.5
A collection of HP specific extensions to the 802.3 Repeater MIB for products in the HP AdvanceStack product line. This group supports devices with multiple repeater segments as well as devices with a single repeater segment.
Status: current Access: read-write
OBJECT-GROUP    

hpicf8023MultiRptrMonitorGroup 1.3.6.1.4.1.11.2.14.10.2.9.1.2.6
A collection of extended counters for 802.3 repeaters in the HP AdvanceStack product line. This group supports devices with multiple repeater segments as well as devices with a single repeater segment.
Status: current Access: read-write
OBJECT-GROUP    

hpicf8023RptrNotifyGroup 1.3.6.1.4.1.11.2.14.10.2.9.1.2.7
********* THIS GROUP IS DEPRECATED ********* A collection of notifications used to indicate changes in port status for 802.3 repeaters in the HP AdvanceStack product line.
Status: deprecated Access: read-write
NOTIFICATION-GROUP    

hpicf8023MultiRptrNotifyGroup 1.3.6.1.4.1.11.2.14.10.2.9.1.2.8
A collection of notifications used to indicate changes in port status for 802.3 repeaters in the HP AdvanceStack product line. Notifications in this group use different traps for good->bad than are used for bad->good (similar to linkUp/linkDown).
Status: current Access: read-write
NOTIFICATION-GROUP    

hpicf8023RpMauAutoNegGroup 1.3.6.1.4.1.11.2.14.10.2.9.1.2.9
A collection of objects for managing MAUs attached to repeater ports with managed auto-negotiation.
Status: current Access: read-write
OBJECT-GROUP    

hpicf8023Rptr100BasicGroup 1.3.6.1.4.1.11.2.14.10.2.9.1.2.10
A collection of HP specific extensions to the 802.3 Repeater MIB for products in the HP AdvanceStack product line. This group supports devices with multiple repeater segments as well as devices with a single repeater segment. This group supports devices with 100BaseT repeater segments.
Status: current Access: read-write
OBJECT-GROUP